HomeMy WebLinkAboutProject Narratives - 11/14/2025
kimley-horn.com 3325 South Timberline Road, Suite 130, Fort Collins, CO 80525 970.822.7911
Project Narrative - Pedersen Toyota Fort Collins
Site Address:
4455 S. College Ave, Fort Collins, CO
Final Development Plan Submittal Date:
September 3, 2025
Past Meeting Dates:
• Conceptual Design Review 12/5/2024
• Neighborhood Meeting 01/15/2025
• MJA Planning and Zoning Commission Hearing 06/25/2025
Applicant:
Pedersen Properties, LLLP. c/o Mark Pedersen
Pedersen Toyota Background and Values “Driven By community”
Gerry Pedersen is the founder of Pedersen Toyota which has been in business for almost 60
years. His son Mark Pedersen has worked at the dealership most of his life and took sole ownership
several years ago, Pedersen Toyota is a well-established car dealership that has been a cornerstone of
the community for nearly 60 years. Their dedication and commitment to providing exceptional customer
service have earned them a reputation for being reliable and trustworthy in the automotive industry. Over
the decades, Pedersen Toyota has not only become a leading name in the community but has also built a
loyal customer base that spans generations. The dealership's longevity is a testament to Gerry and
Mark's hard work and business acumen, as well as their focus on fostering meaningful relationships with
their clients.
In addition to their business success, Gerry and Mark are known for their active involvement in the local
community. They believe in giving back and have supported numerous local organizations, events, and
charities over the years. Their hands-on approach to both business and community engagement has
solidified their reputation not only as successful entrepreneurs but also as passionate advocates for the
well-being of their community. After nearly five decades of hard work and dedication, Gerry and Mark
Pedersen have undoubtedly left a lasting legacy in the automotive industry and their local area.
(https://www.pedersentoyota.com/community-involvement.html)
The construction project aimed at expanding the Toyota dealership is designed to enhance the overall
customer experience by increasing the space and improving the layout. Additionally, the project will
create more service bays, reducing wait times for vehicle maintenance and repairs. With the addition of
modern amenities, the dealership will provide a more convenient and efficient service, reflecting
Pedersen Toyota’s commitment to customer satisfaction. The new space will also offer a state-of-the-art
showroom, updated customer lounges, ensuring that every visit is a pleasant and streamlined experience.
In addition to the enhanced guest experience, this expansion will provide for an upgraded work
environment and help enrich the lives of the 170+ employees and families which will assist in providing a
better guest experience for those in our community who choose to frequent Pedersen Toyota! This is just
another way to be able to give back to the community that drives the Pedersen name!
kimley-horn.com 3325 South Timberline Road, Suite 130, Fort Collins, CO 80525 970.822.7911
Site Context:
Pedersen Toyota is looking to expand its main dealership showroom and service bay area on their
approximately 5-acre site generally located off the northwest corner of the Kensington Drive and S.
College Avenue Intersection. The existing Peterson Toyota dealership will be partially demolished and
rebuilt per this project proposal. The current showroom will be redesigned and expanded on the eastside
of the existing building and additional service bays will be added to the west side of the building adjacent
to and west of the existing service area which will remain in its original footprint. In total the current
building (26,700SF) will be expanded to include a total area of approximately 51,330SF which will include
a new showroom, service center and additional service bay space within the building.
The 5-acre development area currently covers two parcels of land. The eastern Parel (#9735445001) is
where the main dealership is currently located under approved subdivision 1724, Lot 1, Pedersen Toyota-
Volvo-Saab PUD, the western parcel (#9735445001) has also owned by Pedersen Properties, LLLP. and
encompasses the area covered by approved subdivision 1524, Mini-U-Storage PUD. The proposed
building expansion is planned to encroach over the Lot 1, Pedersen Toyota -Volvo-Saab PUD parcel onto
the Mini-U-Storage PUD parcel boundary. As part of the Major Amendment application process
(MJA250001) which was approved by the City of Fort Collins Planning and Zoning Commission on
6/25/2025, a replat of the existing parcels was included in the MJA approval to combine these two lots
into one new lot effectively replacing the existing PUDs that covers this existing development area.
Proposed Site Design Circulation and Parking:
The existing parking around the site for both customers, employees and vehicle inventory storage will be
redeveloped and new landscaping, parking and pavement over this area is proposed in this plan to
conform to the City of Fort Collins current Land Use Code requirements (See attached Utility Plan
Package and Architectural Elevation drawings included in this FDP submittal package for reference).
Traffic flow ingress/egress is proposed to remain the same with no new access locations proposed. A
Traffic Impact Study for the proposed development area has been completed, reviewed and approved by
the City through the subsequent MJA250001 Application process. This study has a lso been included in
the FDP package for review with this application request. Additionally, an emergency fire access and fire
lane plan, which meets or exceeds the minimum requirements for emergency service access standards
as required under the City of Fort Collins current Land Use Code and additional requirements from the
Poudre Valley Fire Authority, was approved under MJA250001. This plan has been included in the Civil
Design package provided for review in this FDP Submittal package.
Utilities, Stormwater & Grading:
The site currently has an existing 8˝ sanitary sewer service and tap that runs north out of the existing
dealership showroom to a public manhole and 24˝ public sanitary line located in an existing utility
easement north of and adjacent to the property boundary. This existing sanitary sewer service is
proposed to continue to service the property. Additionally , a second 6˝ sanitary sewer service line is
proposed for this project to connect to a new 4-foot in diameter manhole built to connect the new 6˝
service to the existing 24˝ public sanitary sewer line located further west within the same existing utility
easement located on the north end of the property. This new manhole location will be both within the
utility easement and the property boundary. This new sanitary service and tap will be used to provide
adequate service to the proposed expanded vehicle service bays.
The site is also currently serviced by a 1 ½˝ domestic water tap, and one existing 6˝ fire line tap, used
primarily for internal building fire Suppression/Sprinklers . These two water taps are also proposed to
continue servicing this development and connect to the existing public water line on the south side of the
property located within Kensington Road. This development plan is also proposing a new 1.5˝ irrigation
kimley-horn.com 3325 South Timberline Road, Suite 130, Fort Collins, CO 80525 970.822.7911
tap, needed to service the proposed landscaping on site and additionally is proposing a new 6˝ fire
hydrant line to help adequately service a new fire hydrant proposed to be located just west of the western
access off Kensington Road.
The site also has connections to existing gas, electric and communication lines servicing the property.
Our proposal plans to use these existing services on site to continue servicing the development .
Stormwater grading and utility plans have also been provided as part of this FDP submittal package.
Historically, the site drains from south to north towards existing private storm inlets, which ultimately drain
into a storm sewer along S. College Avenue. There are also two existing detention ponds located east of
South Mason Street, and the north pond will be removed, as it has no outlet. The south pond will remain
unchanged and continue to drain through the site as it does today.
Upon redevelopment, our plan is proposing updates to the overall site drainage design, including
development of two Low Impact Development drainage basins (Western and Eastern Basins). Each basin
will include onsite water quality treatment via underground water quality chambers.
• The western basin will outfall into the existing 18˝ storm pipe located in an existing utility
easement along the northern property boundary of the development area.
• The eastern basin will outfall into the existing 38˝ storm pipe located within an existing utility
easement along the east side of the property, paralleling College Ave.
The two outlet points proposed on site have been designed to maintain historic drainage patterns and to
meet or exceed minimum requirements found in the City of Fort Collins current Land Use Code , and from
information and coordination efforts received from the City’s Stormwater Engineering/Water Utilities team
prior to submittal of this Final Development Plan application package.