Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans - Irrigation Plan - 10/15/2025
- - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N IR100 IRRIGATION NOTES & LEGEND 24-027 JMA CBK 25-1015 EXCAVATE AND EXPOSE NON-POTABLE DISTRIBUTION PIPE STUB-OUT IN APPROXIMATE LOCATION SHOWN. CONNECT NEW IRRIGATION MAINLINE TO NON-POTABLE DISTRIBUTION PIPE STUB-OUT USING DUCTILE IRON FITTINGS AND RESTRAINTS. EXTEND NEW MAINLINE PIPE AS SHOWN ON PLANS. COORDINATE EXACT PLACEMENT OF METER, BLOW OUT, MASTER VALVE, AND HYDROMETER ASSEMBLIES WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. CONNECT MASTER VALVE AND FLOW SENSOR TO TWO WIRE CABLE PER MANUFACTURER'S GUIDELINES. PROGRAM HIGH FLOW POINT TO 150% OF FLOW INDICATED ON PLAN. INSTALL WALL MOUNT IRRIGATION CONTROLLER IN THE APPROXIMATE LOCATION SHOWN. ELECTRICAL POWER WILL BE PROVIDED TO WITHIN 5' OF CONTROLLER LOCATION (RE: ELECTRICAL PLANS). COORDINATE EXACT LOCATION OF ELECTRICAL POWER WITH THE ELECTRICAL DRAWINGS AND NECESSARY TRADES ON SITE. PROVIDE ALL NECESSARY CONDUIT AND CONDUCTORS BETWEEN ELECTRICAL POWER SOURCE AND IRRIGATION CONTROLLER AND MAKE ALL NECESSARY CONNECTIONS. COORDINATE INSTALLATION OF CONTROLLER WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. INSTALL DECODER GROUNDING EQUIPMENT THAT MEETS CONTROLLER MANUFACTURER'S GUIDELINES AT LOCATION ADJACENT TO INDICATED REMOTE CONTROL VALVE OR TWO WIRE PATH. GROUNDING ROD IS TO BE INSTALLED A MINIMUM DISTANCE OF 10' AWAY FROM ANY TWO-WIRE RUNS. COORDINATE EXACT LOCATION OF GROUNDING EQUIPMENT WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR GROUNDING AND TESTING THE ENTIRE TWO WIRE PATH PER MANUFACTURER'S GUIDELINES. INSTALL TWO WIRE CABLE WITHIN SEPARATE 1-1/2-INCH CONDUIT WHEN NOT INSTALLED WITH MAINLINE PIPE. CONDUITS TO BE INSTALLED AT 24-INCH DEPTH. INSTALL DETECTABLE WARNING TAPE 6-INCHES BELOW GRADE PLACED OVER CONDUITS. INSTALL RAIN SENSOR ON NEAREST LIGHT POLE. COORDINATE EXACT LOCATION WITH OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. IRRIGATION COMPONENTS SHOWN OUTSIDE OF LANDSCAPED AREA FOR CLARITY ONLY. MAINLINE AND ALL IRRIGATION COMPONENTS TO BE INSTALLED IN LANDSCAPED AREA. FOR FUTURE USE, INSTALL THREE (3), 4-INCH SLEEVES IN APPROXIMATE LOCATION SHOWN. FLAG NOTES 1 2 3 4 5 6 7 8 SLEEVING *CLASS 200 PVC *SIZE PER SPECIFICATIONS MAINLINE PIPE W/ TRACING WIRE *CLASS 200 PVC *SIZE AS SHOWN LATERAL PIPE TO SPRINKLERS AND TREE DRIP RINGS *CLASS 200 PVC *1-INCH UNLESS OTHERWISE NOTED DRIP LATERAL PIPE *UV RADIATION RESISTANT POLYETHYLENE *3/4-INCH SIZE UNLESS OTHERWISE NOTED *EMITTER TYPE: RAIN BIRD XERI-BUG TWO-WIRE CABLE IN CONDUIT UNCONNECTED PIPE CROSSING POINT-OF-CONNECTION (P.O.C.) WATER METER ASSEMBLY *MODEL (1-1/2-INCH): NETAFIM, WM-150-0.1-ER MASTER VALVE ASSEMBLY *MODEL: HUNTER ICV-101G-FS *DECODER: HUNTER ICD-100 SERIES FLOW SENSOR ASSEMBLY *MODEL (1-1/2-INCH): FLOMEC QS200 *DECODER: HUNTER ICD-SEN BLOW OUT ASSEMBLY *REFER TO DETAILS ISOLATION GATE VALVE ASSEMBLY *MODEL (2-1/2-INCH AND SMALLER): MATCO-NORCA #514TX *SIZED TO MATCH MAINLINE SIZE QUICK COUPLING VALVE ASSEMBLY *SIZE: RAIN BIRD 5-RC AIR VACUUM RELIEF VALVE ASSEMBLY *SIZE: 1-1/2-INCH WATERMAN AV-150 REMOTE CONTROL VALVE ASSEMBLY *MODEL: HUNTER ICV-G-FS *SIZE AS SHOWN ON PLANS *BALL VALVE: SPEARS PVC COMPACT *DECODER: HUNTER ICD-100 SERIES DRIP REMOTE CONTROL VALVE ASSEMBLY *MODEL: RAIN BIRD XCZ-100-PRB-COM *DECODER: HUNTER ICD-100 SERIES ZONE CONTROL VALVE ASSEMBLY *BALL VALVE: SPEARS PVC COMPACT FLUSH CAP ASSEMBLY *SIZE: RAIN BIRD OR EQUAL LEGEND SPRAY SPRINKLER: PROS-06-PRS30CV WITH RAINBIRD MPR NOZZLES RADIUS: 5'FLOW (GPM): Q - 0.10 H - 0.20 F - 0.41 RADIUS: 8'FLOW (GPM): Q - 0.26 H - 0.52 F - 1.05 RADIUS: 10' FLOW (GPM): Q - 0.39 H - 0.79 F - 1.58 RADIUS: 12' FLOW (GPM): Q - 0.65 H - 1.30 F - 2.60 RADIUS: 15' FLOW (GPM): Q - 0.92 H - 1.85 F - 3.70 POP-UP ROTARY SPRINKLER: PROS-06-PRS40CV WITH HUNTER MP-800 SERIES ROTARY NOZZLES @ 40 PSI RADIUS:8'-12' FLOW (GPM): Q - 0.23 H - 0.42 F - 0.78 RADIUS: 14'-16'FLOW (GPM): Q - 0.52 H - 0.96 F - 2.00 RADIUS:18'-24'FLOW (GPM): Q - 1.06 H - 2.06 F - 4.08 POP-UP ROTARY SPRINKLER: PROS-06-PRS40CV WITH HUNTER MP STRIP SERIES ROTARY NOZZLES @ 40 PSI RADIUS:5'x15' FLOW (GPM): 0.19 RADIUS:5'x15'FLOW (GPM): 0.19 RADIUS: 5'x15'FLOW (GPM): 0.38 POP-UP GEAR-DRIVEN ROTORS: HUNTER I-25-06-SS @ 50 PSI *SYMBOL WITH HALO IS FULL CIRCLE *SYMBOL WITHOUT HALO IS PART CIRCLE *NUMBER WITHIN IS NOZZLE NOZZLE FLOW(GPM)RADIUS(FEET) 4 3.8 40' 7 7.0 47' 8 8.3 49' 10 10.1 51' 13 11.2 53' 15 13.4 56' 18 14.5 58' POP-UP GEAR-DRIVEN ROTORS: HUNTER I-20-06-SS WITH RAIN BIRD MPR NOZZLES@ 45 PSI RADIUS:25'FLOW (GPM): Q-1.00 H-1.98 F-3.82 RADIUS:30'FLOW (GPM): Q-1.40 H-2.96 F-5.78 RADIUS:35'FLOW (GPM): Q-1.92 H-3.81 F-7.58 INLINE TREE DRIP RING IRRIGATION ASSEMBLY *MODEL: RAIN BIRD XFCV-06-12 *REFER TO DETAIL IRRIGATION CONTROLLER ASSEMBLY: HUNTER A2C-75-D-M *ICC2 CELLULAR CONNECTION (CELL KIT, SERVICE PLAN REQUIRED) *STATION DECODERS: HUNTER ICD-100 *SENSOR DECODERS: HUNTER ICD-SEN *WALL MOUNT RAIN SENSOR MODEL: HUNTER WSS-SEN (WIRELESS SOLAR SYNC) INDICATES CONTROLLER AND CONTROLLER STATION NUMBER INDICATES LATERAL DISCHARGE IN GPM INDICATES REMOTE CONTROL VALVE SIZE IN INCHES VALVE BOXES: RAIN BIRD VB SERIES WITH PURPLE LIDS Q A A-1 2" 94 - BO F25H25Q25 F30H30Q30 F35H35Q35 4 4 R W .5 81 81 82 82 80 80 80 81 82 LS RS SS F M 1.EACH IRRIGATION SYSTEM DESIGN ASSUMES A MINIMUM STATIC PRESSURE AND MAXIMUM FLOW DEMAND AS SHOWN ON THE PLANS FOR THEIR RESPECTIVE POINT-OF-CONNECTION (P.O.C.). THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE. 2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING, OR IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED. BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A. IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHEREVER POSSIBLE. B. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS IS NOT PERMITTED. 6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A. TWO OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVE. B. TWO OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS. 7.SELECT NOZZLES FOR SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND UNIFORM COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF EACH SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE TO BE INSTALLED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED REQUIRES HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. CONTRACTOR IS TO NOTCH AN "X" IN CONCRETE AT LOCATION OF SLEEVES ON BOTH SIDES OF SIDEWALK. 9.CONNECT ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.WITH REGARD TO PIPE SIZING, THE FOLLOWING SHOULD BE NOTED: A. IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN TWO IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11.INSTALL HE-VAN NOZZLES WHERE SPRAY ANGLES ARE LESS OR GREATER THAN WHAT A FIXED SPRAY NOZZLE CAN IRRIGATE WITHOUT EXCESSIVE OVERSPRAY. GENERAL NOTES A FULLY AUTOMATED SPRINKLER AND DRIP IRRIGATION SYSTEM IRRIGATES TURF AREAS, SHRUB, AND GROUND COVER PLANTING AREAS. NON-POTABLE WATER WILL BE UTILIZED. POINT-OF-CONNECTION REQUIRES A METER, MASTER VALVE AND FLOW SENSOR. A WALL MOUNT IRRIGATION CONTROLLER USING A DECODER SYSTEM WITH TWO-WIRE CABLE PATH MUST BE INSTALLED UNDER THIS CONTRACT. A RAIN SENSOR IS USED TO PAUSE IRRIGATION AT A SPECIFIED RAINFALL THRESHOLD. A FLOW SENSOR AND MASTER VALVE ARE TO BE INSTALLED TO SHUT DOWN THE IRRIGATION SYSTEM IN THE EVENT OF A PIPE BREAK. ISOLATION GATE VALVES ARE PROVIDED TO ISOLATE SECTIONS OF THE SYSTEM FOR REPAIRS OR MAINTENANCE. QUICK COUPLING VALVES HAVE BEEN PROVIDED THROUGHOUT THE SITE FOR INCIDENTAL WATERING. GENERAL DESCRIPTION UP UP UP DN POINT-OF-CONNECTION TO NON-POTABLE DISTRIBUTION SYSTEM SIZE: 1.5-INCH FLOW: 50 GPM AVAILABLE PRESSURE: 85 PSI 12 BO W Q R A MF 6 3 1.5" 1.5" 1.5" 1.5" 1.5" - - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N IR200 IRRIGATION PLAN 24-027 JMA CBK 25-1015 0'20'10'40'60' 1" = 20' - - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N IR300 IRRIGATION DETAILS 24-027 JMA CBK 25-1015 6 ISOLATION GATE VALVE ASSEMBLY N.T.S. 3 FLOW SENSOR ASSEMBLY N.T.S. 4 MASTER VALVE ASSEMBLY N.T.S.5 AIR\VACUUM RELIEF VALVE ASSEMBLY N.T.S. H BO1NON-POTABLE METER ASSEMBLY N.T.S. W 2 WINTERIZATION ASSEMBLY N.T.S. A B C D E F G H I J K A.TRACING WIRE B.12" VALVE BOX WITH COVER C.FINISH GRADE/TOP OF MULCH D.DECODER E.WIRE SLICE, TYPICAL F.FLOW SENSOR G.TWO WIRE CABLE H.FILTER FABRIC I.PVC PIPE J.BRICK (1 OF 4) K.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL NOTES: 1. ALLOW 10 PIPE DIAMETERS UPSTREAM AND 5 PIPE DIAMETERS DOWNSTREAM OF STRAIGHT RUN OF PIPE TO ACHIEVE PROPER FLOW REGIME. 2. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 3. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 4. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OF SENSOR ASSEMBLY. A B C D E F G H I J A.JUMBO VALVE BOX WITH EXTENSION AND COVER (HEIGHT AS REQUIRED) B.FINISH GRADE/TOP OF MULCH C.AIR VACUUM RELIEF VALVE D.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) E.PVC SCH 40 BALL VALVE (SIZE 2") F.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) G.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL H.BRICK (1 OF 4) I.PVC MAINLINE PIPE J.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS K.TRACING WIRE NOTES: 1. OPEN BALL VALVE IN ASSEMBLY 1/4 TURN UNTIL IRRIGATION SYSTEM IS FULLY CHARGED WITH WATER. 2. CLOSE VALVE DURING WINTERIZATION AND OPEN 1/2 TURN AFTER WINTERIZATION OF SYSTEM TO PROTECT VALVE DURING FREEZING WEATHER. 3. REPLACE PVC BALL VALVE WITH BRASS BALL VALVE IN THE EVENT AN AIR VACUUM RELIEF VALVE WITH MALE INLET IS USED. K NOTE: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. A B C D E F G H I A.FINISH GRADE/TOP OF MULCH B.10" ROUND VALVE BOX WITH COVER C.6" PVC CL 200 PIPE (LENGTH AS REQUIRED) D.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL E.BRICK (1 OF 2) F.THREADED BRONZE GATE VALVE WITH SOLID WEDGE, NON-RISING STEM G.PVC MAINLINE H.PVC SCH 40 MALE ADAPTER (1 OF 2) I.TRACING WIRE NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 5. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID. 6. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OF VALVE ASSEMBLY. A B C D E F G H IJ K A.30" LENGTH OF COILED WIRE B.FINISH GRADE C.VALVE BOX EXTENSION (HEIGHT AS REQUIRED) D.WATER PROOF CONNECTION (1 OF 2) E.12" STANDARD VALVE BOX WITH COVER F.SOLENOID VALVE G.PVC PIPE H.BRICK (1 OF 4) I.FILTER FABRIC J.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL K.PVC SCH 40 MALE ADAPTER L.TRACING WIRE L NOTES: 1. FURNISH NOMINAL PIPE AND FITTING SIZES IDENTICAL WITH NOMINAL TAP SIZE UNLESS OTHERWISE NOTED. 2. TRANSITION PVC MAINLINE ELEVATION TO MASTER VALVE ASSEMBLY USING SCH. 40 PVC 45° FITTINGS. A B C D E F G H I J KLM A.12" STANDARD VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.1" BRONZE BALL VALVE FEMALE THREADED ENDS D.1" COPPER MALE ADAPTER E.1" COPPER PIPE (LENGTH AS REQUIRED) F.3" MIN. DEPTH OF 3/4" WASHED GRAVEL G.BRICK (1 OF 4) H.COPPER FEMALE THREADED ADAPTER I.SCH. 40 PVC MALE THREADED ADAPTER J.PVC MAINLINE K.COPPER PIPE L.COPPER TEE M.COPPER PIPE STUB OUT BELOW FROST DEPTH - - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N 24-027 JMA CBK 25-1015 IRRIGATION NOTES & LEGEND IR301 2 REMOTE CONTROL VALVE ASSEMBLY N.T.S. 6 POP-UP ROTOR SPRINKLER ASSEMBLY N.T.S.5 POP-UP SPRAY SPRINKLER ASSEMBLY N.T.S. 3 DRIP REMOTE CONTROL VALVE ASSEMBLY N.T.S. 4 ZONE CONTROL VALVE ASSEMBLY N.T.S. NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY. 5. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 6. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID AND PROPER OPERATION OF BALL VALVE. 7. COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES. 8. SEE DECODER GROUNDING SCHEMATIC FOR ADDITIONAL DECODER GROUNDING INFORMATION. A B C D E F G HI J K L M N O P Q R S T UV W X Y A.DECODER B.WIRE FROM DECODER TO VALVE SEE SPECIFICATIONS C.PVC BALL VALVE D.REMOTE CONTROL VALVE E.WIRE CONNECTOR FROM TWO-WIRE CABLE TO DECODER (1 OF 2) F.CHRISTY ID TAG G.FINISH GRADE H.WIRE CONNECTOR FROM DECODER GROUND WIRE TO BARE COPPER GROUNDING WIRE I.WIRE CONNECTOR FROM DECODER TO SOLENOID VALVE (1 OF 2) J.BARE COPPER GROUNDING WIRE TO GROUNDING PLATE/ROD SEE SPECIFICATIONS K.12" STANDARD VALVE BOX WITH COVER L.PVC LATERAL PIPE M.FILTER FABRIC N.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED) O.PVC SCH 40 EL P.PVC SCH 40 PIPE (LENGTH AS REQUIRED) Q.BRICK (1 OF 4) R.PVC MAINLINE S.TWO-WIRE CABLE T.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL U.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS V.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED, HIDDEN) AND PVC SCH 40 EL W.PVC SCH 40 MALE ADAPTER X.PVC SCH 80 CLOSE NIPPLE Y.GROUNDING PLATE/ROD (SEE DECODER GROUNDING SCHEMATIC) 1 QUICK COUPLING VALVE ASSEMBLY N.T.S. Q A B C D E F G H I A.FINISH GRADE/TOP OF MULCH B.QUICK-COUPLING VALVE C.10" ROUND VALVE BOX WITH COVER D.HARCO QUICK COUPLER ANCHOR E.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED) F.BRICK (1 OF 2) G.PRE-FABRICATED UNITIZED SWING JOINT 1" MIPT INLET X SOC OUTLET H.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS I.PVC MAINLINE PIPE J.COPPER TRACING WIRE NOTES: 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 2. INSTALLATION HEIGHT OF QUICK COUPLER VALVE IN VALVE BOX MUST ASSURE PROPER OPERATION OF QUICK COUPLER KEY. 3. INSTALL SWING JOINT LAY ARM BETWEEN 30° AND 45° OF LATERAL PIPE IN ORDER TO ABSORB DOWNWARD IMPACT. J A B C D E F G H I J K L M N O A.6" ROUND VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.PVC SCH. 40 EL D.PVC BALL VALVE E.PVC SCH. 40 TRANSITION NIPPLE (MIPTxMHT) F.COMPRESSIONxFEMALE HOSE SWIVEL ADAPTER G.DRIP LATERAL PIPING H.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL I.BRICK (1 OF 2) J.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED, 1 OF 2) K.PVC SCH 40 EL L.PVC SCH 40 STREET EL (1 OF 2) M.PVC DRIP MANIFOLD PIPE N.PVC SCH 40 TEE OR EL O.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) A B C D E F A.FINISH GRADE/TOP OF MULCH B.POP-UP SPRAY SPRINKLER C.SWING PIPE, 12" LENGTH D.1/2" MALE NPT x BARB EL E.PVC SCH 40 TEE OR EL F.PVC LATERAL PIPE D SEE NOTE #1 NOTE: 1. INSTALL SWING JOINT LAY ARM BETWEEN 30° AND 45° OF LATERAL PIPE TO ABSORB DOWNWARD IMPACT. A B C D E A.FINISH GRADE B.POP-UP ROTOR SPRINKLER C.PRE-FABRICATED SWING JOINT MIPT INLET x MIPT OUTLET D.PVC LATERAL PIPE E.PVC SCH 40 TEE OR EL A B C DE F V H U Q K L M N O P Q R ST I G WJ A.PRESSURE REGULATING FILTER B.WIRE FROM DECODER TO VALVE SEE SPECIFICATIONS C.DECODER D.WIRE CONNECTOR FROM TWO-WIRE CABLE TO DECODER (1 OF 2) E.CHRISTY I.D. TAG F.JUMBO VALVE BOX WITH COVER G.PVC BALL VALVE H.FINISH GRADE/TOP OF MULCH I.PVC SCH 80 NIPPLE J.3" MINIMUM DEPTH OF 3 4" WASHED GRAVEL K.REMOTE CONTROL VALVE L.PVC SCH 80 TOE NIPPLE M.PVC SCH 40 EL N.PVC SCH 40 PIPE (TYPICAL) (LENGTH AS REQUIRED) O.FILTER FABRIC P.BRICK (1 OF 4) Q.MANIFOLD/DRIP LATERAL. SEE NOTE 8. R.TWO-WIRE CABLE S.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS T.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED, HIDDEN) AND PVC SCH 40 EL U.BARE COPPER GROUNDING WIRE TO GROUNDING PLATE/ROD SEE SPECIFICATIONS V.WIRE CONNECTOR FROM DECODER GROUND WIRE TO BARE COPPER GROUNDING WIRE W.GROUNDING PLATE/ROD (SEE DECODER GROUNDING SCHEMATIC) NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY. 5. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 6. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID, AND PROPER OPERATION OF BALL VALVE. 7. COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES. 8. IN CASES OF DIRECT DRIP LATERAL PIPE CONNECTION INSTALL SCH. 40 PVC BARB FITTING TO PRESSURE REGULATING BASKET. SECURE CONNECTION WITH STAINLESS STEEL PINCH CLAMPS. 9. SEE DECODER GROUNDING SCHEMATIC FOR ADDITIONAL DECODER GROUNDING INFORMATION. - - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N IR302 IRRIGATION DETAILS 24-027 JMA CBK 25-1015 1 TYPICAL DRIP LAYOUT N.T.S.2 FLUSH CAP ASSEMBLY N.T.S. 5 SLEEVING N.T.S. NOTE: 1. INSTALL FLUSH CAP ASSEMBLY AT THE END OF EACH DRIP LATERAL SEGMENT. A B C D E F A.FINISH GRADE/TOP OF MULCH B.6" ROUND VALVE BOX WITH COVER C.FLUSH CAP WITH HOSE THREAD CAP D.DRIP IRRIGATION LATERAL E.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL F.BRICK (1 OF 2) X X X X X X X X X X X X X X X X X X X X X X X X NOTES: 1. EMITTERS SHALL BE LOCATED IMMEDIATELY ADJACENT TO PERENNIALS AND AT THE OUTSIDE PERIMETER OF THE PLANTING PIT OF ALL SHRUBS AND TREES. 2. INSTALL FOUR 1 GPH EMITTERS PER DECIDUOUS TREE. 3. INSTALL THREE 1 GPH EMITTER PER CONIFEROUS TREE. 4. INSTALL TWO 1 GPH EMITTERS PER SHRUB. 5. INSTALL ONE 1 GPH EMITTER PER PERENNIAL. A B C D E F A.DRIP LATERAL PIPE B.CONIFEROUS TREE C.DECIDUOUS TREE D.EMITTER E.SHRUB F.PERENNIAL 4 INLINE TREE DRIP IRRIGATION ASSEMBLY N.T.S. NOTE: 1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN TURF AND NATIVE AREAS 2-3" BELOW GRADE. 2. DIAMETER OF DRIPLINE RINGS ARE DEPENDANT ON TREE CANOPY SIZE. 3. CONTRACTOR SHALL CUT DRIP TUBING AT POINT "X" AND INSTALL FLUSH CAP AS TRUNK DIAMETER INCREASES. 4. APPROXIMATE FLOW PER ASSEMBLY IS 0.23 GPM FOR THE 2-RING ASSEMBLY AND .43 GPM FOR THE 3-RING ASSEMBLY. A B C D E F A.PVC PIPE B.3/4" POLYETHYLENE TUBING: RAIN BIRD XBS BLACK STRIPE PIPE C.EASY FIT COMPRESSION TEE: RAIN BIRD MDCFTEE (QTY AS REQUIRED) D.EASY FIT REMOVABLE FLUSH CAP: RAIN BIRD MDCFCAP (QTY AS REQUIRED) E.LANDSCAPE DRIPLINE TUBING: RAIN BIRD DRIPLINE MODEL XFCV-06-12 (0.6 GPH/EMITTER) F.TIE DOWN STAKE: RAIN BIRD TDS-050 W/BEND (QTY AS REQUIRED) G.TREE ROOTBALL H.EASY FIT COMPRESSION ELBOW RAIN BIRD MDCFEL (QTY AS REQUIRED) G H XX 1' FROM TRUNK 1' A F D C G H E B 1' FROM TRUNK 1'1' SLEEVE SIZING SCHEDULE 12" MINIMUM NOTE: 1. INSTALL SLEEVE SO THAT ITS LOWEST ELEVATION OCCURS AT ONE OR BOTH ENDS - NOT ALONG ITS LENGTH. A B C D A.FINISHED GRADE OF PAVED SURFACE B.SLEEVE FOR LATERAL PIPE C.SLEEVE FOR MAINLINE PIPE D.SLEEVE FOR WIRING 3 WIRE SPLICE ASSEMBLY N.T.S. 1. 2. 3.4. 1/2" 5. NOTE: 1. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS". 1. STRIP ENDS OF WIRE 2. SECURE WIRES INTO WIRE NUT 3. INSERT WIRE NUT INTO GEL-FILLED TUBE 4. POSITION WIRES INTO CHANNELS 5. CLOSE SPLICE KIT FOR SECURED SEAL - - - - - - - - - - - - - - O: \ H A R T F O R D \ B L O O M - S O J O U R N \ P - B L O O M - S O J O U R N . d w g - Ja n a e A d a m s - 10 / 1 5 / 2 0 2 5 L O T 1 - B L O O M F I L I N G N I N E - S O J O U R N PR E L I M I N A R Y D E V E L O P M E N T P L A N ( P D P ) FO R T C O L L I N S , C O 1510 York Street, Suite 302 Denver, CO 80206 720.236.6656 Date: Drawn By: Project No: Checked By: NOT F O R CON S T R U C T I O N 24-027 JMA CBK 25-1015 IRRIGATION NOTES & LEGEND IR303 2 CONTROLLER ASSEMBLY N.T.S. A 3 RAIN SENSOR ASSEMBLY N.T.S. 4 CONTROLLER GROUNDING SCHEMATIC N.T.S. R 1 TRENCHING N.T.S. 6 TRACING WIRE N.T.S. A B C DE A.IRRIGATION CONTROLLER WALL MOUNT B.2" PVC SCH 40 CONDUIT AND FITTINGS C.JUNCTION BOX D.WIRES TO REMOTE CONTROL VALVES E.1" PVC SCH 40 CONDUIT AND FITTINGS TO POWER SUPPLY WALL NOTE: 1. REFER TO IRRIGATION SPECIFICATIONS FOR COVERAGE DEPTH TO BURIED PIPE AND WIRE. A B C D E F G A.WARNING TAPE B.FINISH GRADE C.BACKFILL D.LATERAL/MANIFOLD PIPE E.TWO-WIRE CABLE F.MAINLINE PIPE G.TRACING WIRE FINISHED GRADE ELEVATION VIEW PLAN VIEW NOTE: 1. COPPER TRACING WIRE WILL START AT EACH PUMP STATION (DOGLEG DISCHARGE BELOW GRADE) AND WILL BE ROUTED WITH ALL MAINLINE PIPE AND CENTER PIVOT PIPE. 2. SPLICE TRACING WIRE IN IRRIGATION MAINLINE COMPONENT VALVE BOXES WHEN POSSIBLE, OTHERWISE, PLACE SPLICE IN SEPARATE VALVE BOX. A B C D EF G H A.10" ROUND VALVE BOX B.INSTALL TRACING WIRE TO THE TOP OF VALVE BOX C.WATER PROOF CONNECTION (SEE SPECIFICATIONS) D.PIPE SLEEVE SEE VALVE DETAIL E.TAPE COPPER WIRE TO TOP OF PIPE EVERY 10 FT. F.CONTINUOUS LOOP COPPER TRACING WIRE (SEE SPECIFICATIONS) G.PVC PIPE H.TYP. VALVE NOTE: 1. MOUNT RAIN SENSOR IN SUITABLE LOCATION PER MANUFACTURER'S INSTRUCTIONS. A B C A.RAIN SENSOR B.MOUNTING BRACKET C.POLE NOTES: 1. BURY GROUNDING PLATE A MINIMUM OF 30 INCHES BELOW GRADE. 8'-10' A B C D E F GHI A A.TWO-WIRE CABLE B.VALVE BOX C.REMOTE CONTROL VALVE D.4" X 96" X 0.06" COPPER GROUNDING PLATE: PAIGE 182199L E.DECODER F.SOLDER CONNECTION G.BARE AWG #8 COPPER WIRE H.3M DBR-6 CONNECTION I.BARE COPPER GROUNDING WIRE PROVIDED WITH DECODER 5 TWO WIRE GROUNDING SCHEMATIC N.T.S. PLAN VIEW A.IRRIGATION CONTROLLER ASSEMBLY B.UL LISTED 5/8" X 10' COPPER-CLAD GROUNDING ROD C.UL LISTED 4" X 8' COPPER GROUNDING PLATE D.10" ROUND VALVE BOX WITH COVER E.BRONZE GROUND ROD CLAMP OR CADWELD CONNECTION: PAIGE ELECTRIC F.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL G.BRICK (1 OF 4) H.#6 AWG INSULATED SOLID COPPER WIRE. NO SHARP BENDS. I.SPHERE OF INFLUENCE J.EARTH CONTACT MATERIAL, POWERSET© OR POWERFILL© DEPENDING ON SOIL CONDITIONS K.FINISH GRADE A C B 8' 10' 11' I I 30" MINIMUM 12" SECTION VIEW H H H B C J D G F E NOTES: 1.CONNECT ALL #6 AWG WIRES INSIDE THE CONTROLLER. CONNECT ONE WIRE TO THE CONTROLLER GROUND LUG AND USE A #4 SPLIT BOLT TO CONNECT ALL WIRES TOGETHER. 2.EARTH CONTACT MATERIAL MUST COMPLETELY COVER THE WELD JOINT ON THE GROUND PLATE. K 7 IRRIGATION CONTROLLER PEAK IRRIGATION SCHEDULE