HomeMy WebLinkAboutPlans - Utility Plan - 08/29/2025GSPublisherVersion 1098.5.6.100GSEducationalVersion
PROJECT NO:
MODEL FILE:
AS-002
2403 Woodrich ADU.pln
2503
REVISION LIST:
DateMark Issue
PROJECT
PHASE/SET
CONSULTANTS
8/29/25 Development Application
NOT FOR CONSTRUCTION
W:
\
0
2
Pr
o
j
e
c
t
s
\
0
2
Ac
t
i
v
e
Pr
o
j
e
c
t
s
\
2
4
0
3
Wo
o
d
r
i
c
h
AD
U
\
0
3
Dr
a
w
i
n
g
s
an
d
Mo
d
e
l
s
\
A
r
c
h
i
t
e
c
t
u
r
a
l
\
C
A
D
Fi
l
e
s
\
2
4
0
3
Wo
o
d
r
i
c
h
AD
U
.
p
l
n
Overall Utility Plan
Bedford Workshop LLC
719 ROCKY MOUNTAIN WAY
FORT COLLINS, CO 80526
Fairplay Ct.
Detached ADU
3206 Fairplay Court
Fort Collins, CO 80526
Filing
Brian Bedford, RA
brian@bedfordworkshop.com
512 788 3114
Kate Bedford, RA
kate@bedfordworkshop.com
512 788 4611
N
CIVIL:
TST, Inc. Consulting Engineers
Derek Patterson
dpatterson@tstinc.com
970 226 0557
2
A-201
4
A-201
3
A-201
126
.
3
'
110
'
12
8
.
3
'
56.9
'
6'
EAS
M
'
T
NEW CUSTOMER OWNED AND MAINTAINED ELECTRIC
LINE TO BE INSTALLED BY OWNERS ELECTRICIAN ;
ROUTE TO BE CONFIRMED IN FIELD W/ ELECTRICIAN
NEW POTABLE WATER LINE FROM
EXISTING RESIDENCE
EXISTING ELECTRICAL METER
(NEW ELECTRICAL METER PROPOSED
TO BE IMMEDIATELY ADJACENT)
EXISTING LIGHT POLE
EXISTING CONNEXION
FIBER VAULT
EXISTING UTILITY POST
EXIST. MANHOLE
EXISTING TELEPHONE (VERIFY) VAULT
EXISTING WATER
SHUT-OFF VALVE
NEW ELECTRICAL SERVICE ROUTE TO
METER BY LIGHT AND POWER
UP
1
A-201
6'
EASM
'
T
EXISTING GAS METER -
NO EXTENSION OF GAS
SERVICE TO ADU
DISCUSS ROUTE WITH FORT
COLLINS UTILITY TO MEET OFFSET
REQUIREMENTS AS BEST AS
POSSIBLE
ASSUMED EXISTING SEWER LINE,
DETERMINED BY INVERT
LOCATION INSIDE RESIDENCE
(LOCATION NOT MARKED BY CITY)
PROPOSED NEW SEWER TIE IN
EXIST. IRRIGATION
VALVE CONTROL BOX
KEY:
PROPERTY LINE
EXISTING FENCE
ELECTRIC LINE
SANITARY SEWER LINE
GAS LINE
POTABLE WATER LINE
EXISTING FACE OF CURB
EXISTING:PROPOSED:
TELEPHONE LINE
FIBER LINE
APPROVED:
City Engineer,Approved Sheets Date
APPROVED:
Water & Wastewater Utility,Approved Sheets Date
APPROVED:
Stormwater Utility,Approved Sheets Date
APPROVED:
Park Planning and Development,Approved Sheets Date
APPROVED:
Traffic Operations,Approved Sheets Date
APPROVED:
Environmental Planner,Approved Sheets Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
SCALE: 1" = 20'1 OVERALL UTILITY PLAN
0 10'20'40'
Utility Plan Notes
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN
UNDERGROUND UTILITIES ARE APPROXIMATE
WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE
THE RESPONSIBILITY OF THE CONTRACTOR TO
CONFIRM THE EXISTANCE AND LOCATION OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE
WORK (BOTH THOSE KNOW AND DOCUMENTED IN
THESE DRAWINGS AND THOSE UNKNOWN),
BEFORE COMMENCING CONSTRUCTION. EXACT
LOCATIONS OF NEW SERVICES SHALL BE PER THE
REQUIRMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE
FIELD.
2. CONTRACTOR TO USE ALL APPLICABLE CITY OF
FORT COLLINS UTILITY STANDARDS AND
SPECIFICATIONS FOR ALL UTILITY MATERIALS.
3. DESPITE ALL PROPER EFFORTS OF PROFESSIONAL
CARE AND RESPONSIBILITY, IT IS IMPOSSIBLE TO
FULLY DISPLAY SUBSURFACE INFORMATION PRIOR
TO EXCAVATION. THIS IS ESPECIALLY TRUE IN
AREAS OF INFILL AND REDEVELOPMENT.
UNKNOWN SUBSURFACE CONDITIONS CAN HAVE
COST AND SCHEDULE IMPLICATIONS. PRIOR TO
FINALIZING CONTRACT TERMS, IT IS STRONGLY
RECOMMENDED THAT THE OWNER AND GENERAL
CONTRACTOR DISCUSS AND FORMULATE A
STRATEGY FOR DEALING WITH SUCH
CIRCUMSTANCES WHEN THEY ARISE, PRIOR TO
START OF EXCAVATION. THE ARCHITECT,
ENGINEE(S), AND CONSTRUCTION SURVEYOR (IF
APPLICABLE) SHOULD BE INFORMED OF THE
PROTOCAL.
4. PER LIGHT AND POWER: ALL FACILITIES MUST HAVE
A TEN FOOR CLEARANCE FROM ALL WATER,
WASTEWATER, AND STORM SEWER FACILITIES, AND
A THREE FOOT CLEARANCE FROM ALL OTHER
UTILITIES WITH THE EXCEPTION OF
COMMUNICATION LINES.
5. THE DESIGN OF THIS DEVELOPMENT MUST
FOLLOW CITY OF FORT COLLINS UTILITIES WATER
AND WASTEWATER (WW) DESIGN CRITERIA,
SPECIFICATIONS, AND DETAILS, INCLUDING THE
FOLLOWING UNLESS PERMITTED OTHERWISE:
10' MIN. BTWN WATER & WASTEWATER SERVICES
6' MIN. BTWN TREES & WATER OR WW SERVICES
4' MIN. BTWN SHRUBS & WATER OR WW SERVICES
10' MIN. BTWN STORM DRAIN PIPES & OTHER
UTILITIES
(SERVICE LINES OF THE SAME TYPE MAY BE JOINT
TRENCHED W/ 3' OF SEPARATION)
6. PER FT. COLLINS WATER UTILITIES, THIS PROPERTY
SERVED BY:
6" WATER MAIN IN FAIRPLAY COURT; EXISTING 3/4"
SERVICE TO HOUSE
8" WASTEWATER MAIN IN FAIRPLAY COURT;
EXISTING WASTEWATER SERVICE TO HOUSE (SIZE
UNSPECIFIED)N