HomeMy WebLinkAboutSupporting Documentation - Response to Comments - 07/29/2025 Page 1 of 3 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6689 970.224.6134 - fax fcgov.com/developmentreview July 29, 2025 Brian Bratcher DHIC - ENCLAVE LLC 9555 S Kingston Ct. Englewood, CO 801125943 RE: Enclave at Redwood Subdivision, FDP250007, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of Enclave at Redwood Subdivision. If you have questions about any comments, you may contact the individual commenter or direct your questions through your Development Review Coordinator, Todd Sullivan via phone at 970-221-6695 or via email at tsullivan@fcgov.com. Comment Summary: Department: Development Review Coordinator Contact: Todd Sullivan tsullivan@fcgov.com 970-221-6695 Topic: General Comment Number: 1 INFORMATION: I will be your primary point of contact throughout the development review and permitting process. If you have any questions, need additional meetings with the project reviewers, or need assistance throughout the process, please let me know and I can assist you and your team. Please include me in all email correspondence with other reviewers and keep me informed of any phone conversations. Thank you! Comment Number: 2 SUBMITTAL: As part of your submittal, a response to the comments provided in this letter and a response to plan markups is required. The final letter is provided to you in Microsoft Word format. Please use this letter to insert responses to each comment for your submittal, using a different font color. Please use the markups to insert responses to each comment on plans. Please do not flatten markup responses. Provide a detailed response for any comment asking a question or requiring an action. Any comment requesting a response or requiring action by you with a response of noted, acknowledged etc. will be considered not addressed. You will need to provide references to specific project plans, pages, reports, or explanations of why comments have not been addressed [when applicable]. Page 2 of 3 Comment Number: 3 SUBMITTAL: Correct file naming is required as part of a complete submittal. Please follow the Electronic Submittal Requirements and File Naming Standards found here: https://www.fcgov.com/developmentreview/files/electronic-submittal-requiremen ts-and-file-naming-standards_v1_8-1-19.pdf?1703783275 File names should have the corresponding number, followed by the file type prefix, project information, and round number. For example: 1_SITE PLAN_Project Name_FDP_Rd1. A list of numbers and prefixes for each file can be found at the link above. Comment Number: 4 SUBMITTAL: All plans should be saved as optimized/flattened PDFs to reduce file size and remove layers. Per the Electronic Submittal Requirements AutoCAD SHX attributes need to be removed from the PDF’s.AutoCAD turns drawing text into comments that appear in the PDF plan set, and these must be removed prior to submittal as they can cause issues with the PDF file. The default setting is "1" ("on") in AutoCAD. To change the setting and remove this feature, type "EPDFSHX" (version 2016.1) or “PDFSHX (version 2017 and newer) in the command line and enter "0". Read this article at Autodesk.com for more on this topic: https://knowledge.autodesk.com/support/autocad/troubleshooting/caas/sfdcarti cles/sfdcarticles/Drawing-text-appears-as-Comments-in-a-PDF-created-by-Aut oCAD.html Comment Number: 6 INFORMATION: Please resubmit within 180 days, approximately 6 months, to avoid the expiration of your project. Comment Number: 7 INFORMATION: ANY project that requires four or more rounds of review would be subject to an additional fee of $3,000.00. Comment Number: 8 NOTICE: A Development Review sign will be posted on the property. This sign will be posted through the final decision and appeal process. A request for the removal of signs will be made by your Development Review Coordinator at the appropriate time. Comment Number: 10 06/10/2025: FOR HEARING: This proposed project is processing as a Type 2 Development Plan. The decision maker for Type 2 is the Planning and Zoning (P&Z) Commission. For the hearing, we will formally notify surrounding property owners within 800 feet (excluding public right-of-way and publicly owned open space). All "For Hearing" comments need to be addressed and resolved prior to moving forward with scheduling the Hearing. Staff will need to agree the project is ready for Hearing approximately 4 to 8 weeks prior to the hearing. I have attached the P&Z schedule, which has key dates leading up to the hearing. Comment Number: 11 07/29/2025: FOR HEARING: Staff has agreed that this project is eligible to move forward to hearing for a formal decision. We will place this project on the August 21, 2025 Planning & Zoning Commission Hearing Agenda and request that it be placed on the Consent Agenda with a recommendation for Approval. At our Project Review Meeting, we will discuss what items will be required for the hearing and what preparation should be done in the event this item is pulled from the Consent Agenda. Page 3 of 3 Comment Number: 12 07/29/2025: FOR RECORDING: There are redlines/markups on the plat that remain to be addressed prior to this being approved for recording documents. Staff has agreed that the next revisions can be reviewed with a two-week Quick Check review. You can submit the revised plat for review on any business day of the week and the documents will be routed for review the following business day. Staff will have ten (10) business days to perform their review and provide their comments and any markups resulting from that review. These comments and markups will be forwarded to you on the 11th business day. If an additional round of review is required following this Quick Check, the Additional Rounds of Review Fee of $3,000.00 will apply. I would encourage your surveyor to work with John Von Nieda with the City to clarify any questions or concerns prior to the next resubmittal to help insure a successful review package. Department: Technical Services Contact: Jeff County jcounty@fcgov.com 970-221-6588 Topic: Plat Comment Number: 1 07/25/2025: FOR RECORDING: Please make changes as marked in the Technical Services (TS) markup PDF. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. If you have any specific questions about the markups, please contact John Von Nieda at 970-221-6565 or jvonnieda@fcgov.com 06/10/2025: FOR FINAL APPROVAL: Please make changes as marked in the Technical Services (TS) markup PDF. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. If you have any specific questions about the markups, please contact John Von Nieda at 970-221-6565 or jvonnieda@fcgov.com Department: Internal Services Contact: Russell Hovland rhovland@fcgov.com 970-416-2341 Topic: Building Insp Plan Review Comment Number: 1 06/06/2025: FOR HEARING: If there are existing buildings on these properties, contact Building Services to go over fire separation distance requirements. Please confirm.