Loading...
HomeMy WebLinkAboutPlans - Utility Plan - 08/20/2025S M A S O N S T SITE CO L L E G E B L V D CREGER DR COLBOARD DR MA X G U I D E W A Y VICINITY MAP BENCHMARK PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. VOA SWITCHGRASS UTILITY PLANS LOT 2, CREGER PLAZA, THIRD REPLAT CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO AUGUST 20, 2025 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g SCALE 1" = 200' 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS COVER SHEET C1.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 CONTACT LIST SURVEYOR ENGINEERING SERVICE COMPANY JUSTIN CONNOR, PLS 14190 E EVANS AVENUE AURORA, CO 80014 CIVIL ENGINEER SHOPWORKS ARCHITECTURE TED SWAN, PE 301 W. 45TH AVE DENVER, CO 80216 ARCHITECT SHOPWORKS ARCHITECTURE ED PARCELL, AIA 301 W. 45TH AVE DENVER, CO 80216 LANDSCAPE ARCHITECT RIPLEY DESIGN, INC RUSS LEE, PLA 419 CANYON AVENUE, SUITE 200 FORT COLLINS, CO 80521 OWNER/DEVELOPER VOLUNTEERS OF AMERICA DOUG SNYDER 2660 LARIMER ST DENVER, CO 80205 GENERAL NOTES 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CURRENT LARIMER COUNTY URBAN AREA STANDARDS. 2. ONSITE GRADING AND PAVING SHALL CONFORM TO THE GEOTECH REPORT. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD. 3. ALL EXISTING IMPROVEMENTS (INCLUDING PAVING, UTILITIES, ETC) AND ELEVATIONS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD. 4. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL PROJECT PERMITS ASSOCIATED WITH CONSTRUCTION 5. CONTRACTOR SHALL MAINTAIN AT LEAST ONE PRINTED COPY OF THE APPROVED PLANS, SPECIFICATIONS AND STANDARDS ON THE JOB SITE AT ALL TIMES. 6. CONTRACTOR IS RESPONSIBLE FOR BEING AWARE OF, NOTIFYING, COORDINATING AND SCHEDULING ALL INSPECTIONS REQUIRED FOR FINAL APPROVALS AND PROJECT ACCEPTANCE. 7. PRIOR TO FINAL ACCEPTANCE, ALL DISTURBED PORTIONS OF ROADWAY ROW SHALL BE CLEANED UP AND RESTORED TO THEIR ORIGINAL CONDITION, SUBJECT TO CITY AND COUNTY APPROVAL. 8. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING ADEQUATE TRAFFIC CONTROL THROUGHOUT THE PROJECT, INCLUDING PROPER TRAFFIC CONTROL DEVICES AND/OR PERSONNEL AS REQUIRED. AFFIRMATION STATEMENT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design, revisions, and record conditions that I have noted on these plans. ____________________________________________ THEODORE SWAN, PE 43903 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 SHEET INDEX SHEET # C1.0 COVER SHEET 1 C1.1 NOTES SHEET 2 C1.2 CONSTRUCTION NOTES SHEET 3 C1.3 EROSION CONTROL NOTES SHEET 4 C2.0 DEMO AND INITIAL EROSION CONTROL 5 C2.1 INTERIM EROSION CONTROL 6 C2.2 FINAL EROSION CONTROL 7 C2.3 EROSION CONTROL DETAILS 8 C3.0 HORIZONTAL CONTROL PLAN 9 C4.0 GRADING PLAN 10 C5.0 UTILITY PLAN 11 C6.0 STORM PLAN AND PROFILE 12 C6.1 STORM PLAN AND PROFILE 13 C7.0 EXTENDED DETENTION VAULT PLAN 14 C7.1 EXTENDED DETENTION VAULT DETAILS 15 C7.2 EXTENDED DETENTION VAULT DETAILS 16 C8.0 CONSTRUCTION DETAILS 17 C8.1 CONSTRUCTION DETAILS 18 DR1 DRAINAGE PLAN 19 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS NOTES SHEET C1.1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the Local Entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the Local Entity Engineer. Use of these plans after the expiration date will require a new review and approval process by the Local Entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the Local Entity, as beneficiary of said engineer’s work, for any errors and omissions contained in these plans, and approval of these plans by the Local Entity Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the Local Entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other “dry” utility installations, shall conform to the Local Entity standards and specifications current at the date of approval of the plans by the Local Entity Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Engineer shall contact the Utility Notification Center of Colorado (UNCC) at 1- 800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the Local Entity prior to beginning construction. 10. The Developer shall coordinate and cooperate with the Local Entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The Local Entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the Local Entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The Local Entity shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the Local Entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study (name of the study and date) by (Engineering Firm) shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the Local Entity street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the Local Entity Engineering Inspector (Fort Collins - 221-6605) and the Local Entity Erosion Control Inspector (Fort Collins – 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the Local Entity Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the Local Entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the Local Entity’s default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the Local Entity Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the Local Entity inspector. The engineer or surveyor must certify in a letter to the Local Entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the Lo26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County FloodPlain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (Local Entity, County or State), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact Local Entity Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development’s local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the Local Entity Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the Local Entity. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. cal Entity before installation of base course or asphalt will be allowed on the streets. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the Local Entity Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Local Entity’s Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the Local Entity Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: BENCHMARK: ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM X.XX’. 41. All stationing is based on centerline/flowline (insert proper word) of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer’s expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Local Entity Construction Inspector before any cuts are made. Patching shall be done in accordance with the Local Entity Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Local Entity Engineer and/or the Local Entity Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all “T” intersections. 46. After acceptance by the Local Entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The Local Entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: (list). 48. Approved Variances are listed as follows: (Plan set must have a list of all applicable variances for the project). 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS CONSTRUCTION NOTES SHEET C1.2 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 STREET IMPROVEMENT NOTES 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the Local Entity Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the Local Entity Engineer in Loveland. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the Local Entity Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the Local Entity Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the Local Entity Inspector and prior to installation of asphalt. Gutters that hold more than ¼ inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. “Proof roll” vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the Local Entity Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The Local Entity Engineer shall be notified at least 24 hours prior to the “proof roll.” All “proof rolls” shall be preformed in the presence of an Inspector. 10. Loveland only. 2-inch PVC conduit (with 3’ min. cover) shall be provided along arterial roadways with pull boxes at 500’ spacing or deflection points for future traffic signal interconnect. TRAFFIC SIGNING AND PAVEMENT MARKING NOTES 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per Local Entity Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines shall be latex paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the Local Entity Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Latex paint applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the Local Entity Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period, the Local Entity Engineer reserves the right to require additional signage and/or striping if the Local Entity Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. 16. Contractor is responsible for removing all anchors, posts, signs and/or delineators in Construction area. Contractor may keep the signs, or call the City Traffic Division to have them removed. 17. No “Reset” anchors, posts, signs, and/or delineators will be accepted. 18. All anchors, posts, signs, and/or delineators shall be new and be consistent with the LCUASS criteria. STORM DRAINAGE NOTES 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the final drainage and erosion control study (name of the study and date) by (Engineering Firm) shall be followed and implemented. 3. Prior to final inspection and acceptance by The City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 4. See City of Fort Collins Stormwater Criteria Manual – Appendix F Construction Control Measures Standard Notes and Standard Erosion Control Notes. WATERLINE NOTE 1. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS EEEEEE E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST ST ST ST ST ST ST ST ST ST ST STST ST ST SS SS SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) FIRE HYDRANT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN MATCH EXISTING GRADE AT PROPERTY LINE SSA LOC LOC LOC LOC LOC LOC LOC RS RS IPS VTC IPS EXISTING ELECTRIC AND LIGHTING TO BE REMOVED IN SITE BOUNDARIES EXISTING ASPHALT AND STRIPING TO BE REMOVED IN SITE BOUNDARIES EXISTING TREES TO BE REMOVED IN SITE BOUNDARIES EXISTING STAIRS TO BE REMOVED EXISTING STAIRS TO BE REMOVED EXISTING TREES TO BE REMOVED IN SITE BOUNDARIES EXISTING STORM INLET TO BE CAPPED WITH CONCRETE LID AND BURIED EXISTING STORM INLET TO BE CAPPED WITH CONCRETE LID AND BURIED EXISTING ATTACHED WALKWAY TO BE REMOVED WHERE INDICATED EXISTING CURB ISLANDS TO BE REMOVED IN SITE BOUNDARIES FIBER OPTIC VAULT TO BE RELOCATED AS REQUIRED FOR NEW SIDEWALK EXISTING WALKWAY TO BE REMOVED WHERE INDICATED EXISTING TREES TO REMAIN EXISTING TREE TO REMAIN REMOVE EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN Pl o t t e d B y : Te d S w a n La y o u t : C2 . 0 I N I T I A L E R O S I O N C O N T R O L A N D D E M O P L A N - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 7 A M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - I n i t i a l . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS DEMO AND INITIAL EROSION CONTROL C2.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Erosion Control-Initial REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW SEDIMENT TRAP REINFORCED SILT FENCE SILT FENCE STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SOIL STOCKPILE CHECK DAM 5281 5280 5281 5280 ST ST SF SSA VTC IPS RS DD TSB SP LOC CD ST SFR 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. TABLE OF CALCULATIONS TOTAL AREA OF DISTURBANCE 1.53 AC TOTAL ONSITE AREA OF DISTURBANCE 1.40 AC TOTAL OFFSITE AREA OF DISTURBANCE 0.13 AC TOTAL STORAGE/STAGING AREAS NOT 0 AC INCORPORATED IN ONSITE/OFFSITE AREAS TOTAL AREA OF NEW OR IMPROVED HAUL ROADS(OFFSITE)0 AC HEAVY CONSTRUCTION VEHICLE TRAFFIC AREAS OFFSITE APPROXIMATE PERCENT OF THE PROJECT THAT WILL BE DISTURBED AT ANY ONE TIME ESTIMATED PRE-EXISTING PERCENT VEGETATIVE DENSITY 10.4% OR PERCENT VEGETATIVE COVER BEFORE DISTURBANCE EXISTING SOIL TYPE CLAY AND SAND (TYPE C HYD GROUP) DEPTH TO GROUNDWATER 8' AVG DEPTH NUMBER OF PHASES ASSOCIATED WITH A PROJECT 1 TOTAL VOLUME OF MATERIAL IMPORTED TO OR EXPORTED 3254 CU YDS IMPORT FROM THE PROJECT TOTAL AREA OF OFFSITE STOCKPILING OF FILL FROM THE 0 AC PROJECT OR BORROW FROM STRIPPING THE OFFSITE AREA STEEPEST SLOPE DISTANCE FROM A RIPARIAN AREA OR SENSITIVE AREA N/A 5038 50 3 8 50385038 503 9 503 9 50 3 9 50 3 9 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST ST ST ST ST ST ST ST ST ST ST STST ST ST SS SS WWW WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) FIRE HYDRANT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC ST ST ST ST ST STSTSTEXISTING PIPE (TYP) 50 3 9 503 9 5039 EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN MATCH EXISTING GRADE AT PROPERTY LINE SS SS SSSS BUILDING EXCAVATION AREA CD CD DD 240 LF DD 85 LF DD 65 LF DD 35 LF LOC LOC LOC LOC LOC LOC LOC RS RS SSA VTC IPS 5037 5038 50 3 8 5038 5040 5038 5039 50415041 50 3 8 50 3 9 50 4 0 503 9 50 4 1 50 4 2 TSB TSB CWA 4" S L O T T E D P V C P I P E ST ST ST ST IPS IPS IPS IPS Pl o t t e d B y : Te d S w a n La y o u t : C2 . 1 I N T E R I M E R O S I O N C O N T R O L P L A N - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 7 A M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - I n t e r i m . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS INTERIM EROSION CONTROL PLAN C2.1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N S T -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Erosion Control-Interim REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SEEDING AND MULCHING CHECK DAM CONCRETE WASHOUT AREA 5281 5280 5281 5280 ST ST SSA VTC IPS RS DD TSB SM LOC CD NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. CWA 5038 50 3 8 50385038 503 9 503 9 50 3 9 50 3 9 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 BBBBB B B B B B B B B SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST ST ST ST ST ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT ST ST ST SS SS UP FD VAN T WWW WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) MAIN ENTRY 10' TREE LAWN FIRE HYDRANT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC ST ST ST ST ST STSTSTEXISTING PIPE (TYP) 4' CONCRETE PAN 50 3 9 503 9 5039 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN COURTYARD (RE LANDSCAPE) EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN MATCH EXISTING GRADE AT PROPERTY LINE 5037 50 3 7 5038 50 3 8 5038 5039 50 3 8 50 3 9 5040 5038 5039 50415041 50 4 0 50 3 9 50 4 1 SSA VTC TSB SM SM SM SM SM CWA SM SM SM BUILDING FFE: 5039.50 BUILDING FFE: 5039.50 ST ST ST ST Pl o t t e d B y : Te d S w a n La y o u t : C2 . 2 F I N A L E R O S I O N C O N T R O L P L A N - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 7 A M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - F i n a l . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS FINAL EROSION CONTROL PLAN C2.2 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Erosion Control-Final REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SEEDING AND MULCHING CHECK DAM CONCRETE WASHOUT AREA 5281 5280 5281 5280 ST ST SSA VTC IPS RS DD TSB SM LOC CD CWA 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 12345 A B C D 12345 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ E r o s i o n C o n t r o l D e t a i l s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EROSION CONTROL DETAILS C2.3 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N ST -------- ---- -------- FO R T C O L L I N S , C O 80 5 2 5 Va l u e 24046_Erosion Control Details REF PLAN ----2 3 BBBBB B B B B B B B B ST ST ST SS SS AA 2 3 4 5 6 BB CC EE II KK DD JJ HH 1 GG A1A1 FF 4.1 UP FD VAN T SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) BUILDING GRID LINE J-5 N 1,438,414.18 E 3,117,833.40 MAIN ENTRY 6 ACCESSIBLE PARKING SIGN BIKE RACKS (TYP) (SEE LANDSCAPE FOR DETAILS) 10' TREE LAWN 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 EXISTING FIRE HYDRANT DETECTABLE WARNING (TRUNCATED DOMES) EXTENDED DETENTION VAULT (DETENTION AND WATER QUALITY) GRID LINE B-3 N 1,438,306.43 E 3,117,786.07 LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC 8 5 7 12 5 3 FDC 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 112" DOMESTIC WATER METER VAULT FIRE HYDRANT STOP SIGN COURTYARD (RE LANDSCAPE) ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB VAN ACCESSIBLE PARKING SIGN EV STALL EV STALL LOADING STALL 4' CONCRETE PAN ADA RAMP PER LARIMER COUNTY URBAN AREA DWG 1606 STANDARD DRIVEWAY APPROACH AND CROSSPAN PER LARIMER COUNTY URBAN AREA DWG 706.2 & 708 WATER ENTRY ROOM TRANSITION FROM 6" TO ZERO HEIGHT CURB 15' ACCESSIBLE PARKING STALL (TYP) DOG PARK TRASH PICKUP LOCATION TRASH ROOM INDOOR BIKE PARKING EXISTING DRIVEWAY APPROACH AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN 26' EXISTING FIRE LANE EASEMENT 1 1 2 2 2 1 ELECTRIC TRANSFORMER PARKING STALLS TO BE LEASED BY NEIGHBORING PROPERTY 3/4" IRRIGATION METER VAULT EXISTING STOP SIGN TO REMAIN INSTALL DECTECTABLE WARNING STRIP IN SIDEWALK INSTALL DECTECTABLE WARNING STRIP IN SIDEWALK 7' SIDEWALKEASEMENT EXISTING FIRE LANE SIGN TO BE RELOCATED EXISTING FIRE LANE SIGN TO REMAIN FIRE LANE SIGN PER DETAIL (THIS SHEET) FIRE LANE SIGN PER DETAIL (THIS SHEET) Pl o t t e d B y : Te d S w a n La y o u t : C3 . 0 H O R I Z O N T A L C O N T R O L P L A N - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 7 A M Fi l e N a m e : 24 0 4 6 _ S i t e P l a n . d w g SITE PLAN LEGEND PROPERTY LINE EXISTING CURB AND GUTTER EXISTING FIRE HYDRANT PROPOSED FENCE PROPOSED CURB AND GUTTER PROPOSED SPILL GUTTER PROPOSED SIDEWALK (PUBLIC 6" DEPTH, PRIVATE 4" DEPTH,, 7" TRASH PICKUP LOCATION) PROPOSED ASPHALT & SAWCUT (4" HMA, 6" ABC) PROPOSED FIRE HYDRANT PROPOSED TRANSFORMER PROPOSED SITE LIGHTING PROPOSED SIGNAGE PROPOSED ADA ACCESSIBLE ROUTE PROPOSED TREE LOCATION NUMBER OF PARKING STALLS T SIGHT TRIANGLE NOTES 1 - AASHTO SIGHT TRIANGLE - NO OBSTRUCTIONS OVER 24" PERMITTED WITHIN THE SIGHT TRIANGLE. BASED ON 4.04.2.10.1.01 2 - PEDESTRIAN SIGHT TRIANGLE - 10' LEG ON WALKWAY AND DRIVEWAY NO OBSTRUCTIONS OVER 30" THAT ARE WIDER THAN 18" ARE PERMITTED WITHIN THIS TRIANGLE # SITE PLAN NOTES 1.CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.ALL DIMENSIONS FROM FLOWLINE AND OUTSIDE BUILDING FACE UNLESS OTHERWISE NOTED 3.ALL ADA ACCESSIBLE RAMPS TO INCLUDE DETECTABLE WARNING PADS. 4.CONTRACTOR SHALL REMOVE AND REPLACE DAMAGED CURB, GUTTER, PAVING, AND LANDSCAPED AREAS OUTSIDE THE LIMITS OF SITE AND RESTORE BACK TO ITS ORIGINAL CONDITION. 5.ALL ENTRANCES ARE PRIVATE UNLESS OTHERWISE NOTED. 6.ADDITIONAL ROADWAY IMPROVEMENTS MAY BE REQUIRED PENDING TIS UPDATES. 7.SITE SURFACE SHOULD BE SCARIFIED TO A DEPTH OF AT LEAST 8 INCHES. FILL MATERIAL TO BE PLACED IN 8" LOOSE LIFTS, MOISTURE CONDITIONED AND COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF STANDARD PROCTOR MAXIMUM DRY DENSITY 8.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. N 40'0 SCALE: 1" = 20' 20' 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS HORIZONTAL CONTROL PLAN C3.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Site Plan REF PLAN ----2 3 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 R3-5R 30"x36" 5038 50 3 8 50385038 503 9 503 9 50 3 9 50 3 9 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 BBBBB B B B B B B B B SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST ST ST ST ST ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT ST ST ST SS SS UP FD VAN T WWW WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) MAIN ENTRY 10' TREE LAWN FIRE HYDRANT DETECTABLE WARNING (TRUNCATED DOMES) LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC ACCESSIBLE PARKING STALL (TYP) ST ST ST STMH-A03 4' STORM MANHOLESTINLET-A04 TYPE 16 COMBO INLET ST ST STSTSTEXISTING PIPE (TYP) ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB 4' CONCRETE PAN TRANSITION FROM 6" TO ZERO HEIGHT CURB 15' 50 3 9 503 9 5039 503 8 . 1 2 503 7 . 6 2 503 8 . 1 1 503 8 . 4 8 503 9 . 2 0 503 7 . 8 5 503 8 . 5 0 503 8 . 6 1 503 9 . 0 5 503 9 . 3 1 503 9 . 1 9 503 8 . 4 3 503 8 . 8 4 503 8 . 7 6 503 8 . 8 9 M E 503 8 . 4 8 503 9 . 1 4 503 7 . 4 8 503 7 . 4 4 503 7 . 2 7 503 7 . 2 4 503 7 . 6 4 503 7 . 7 3 503 7 . 4 6 503 7 . 3 0 503 8 . 9 8 503 8 . 9 7 5038.93 503 9 . 2 8 503 9 . 2 6 503 8 . 6 5 503 8 . 6 5 EXTENDED DETENTION VAULT (DETENTION AND WATER QUALITY) SEE EDB PLANS FOR DETAILS 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 ADA RAMP PER LARIMER COUNTY URBAN AREA DWG 1606 STANDARD DRIVEWAY APPROACH AND CROSSPAN PER LARIMER COUNTY URBAN AREA DWG 706.2 & 708 503 8 . 2 2 ME 503 8 . 2 5 ME 503 8 . 7 4 ME 503 9 . 0 7 ME 503 9 . 1 5 ME 503 8 . 9 9 M E EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN BUILDING FFE: 5039.50 BUILDING FFE: 5039.50 503 8 . 9 3 503 8 . 5 8 COURTYARD (RE LANDSCAPE) 503 8 . 0 6 503 7 . 8 3 503 7 . 0 7 503 8 . 2 1 503 7 . 9 7 503 8 . 1 4 503 8 . 4 0 503 8 . 4 3 503 8 . 7 2 503 8 . 1 5 503 8 . 1 7 503 8 . 9 1 503 8 . 8 1 503 8 . 1 4 503 8 . 1 5 503 7 . 5 7 EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN 503 8 . 3 0 503 8 . 2 2 503 8 . 9 9 M E 503 8 . 9 4 M E 0. 5 % 0. 5 % 0. 5 % 0. 5 % ACCESSIBLE PARKING SIGN 0.8%0.5%503 7 . 9 0 503 8 . 7 6 503 8 . 4 7 503 8 . 1 6 503 7 . 5 1 503 7 . 4 2 503 7 . 4 5 503 7 . 7 2 503 7 . 8 9 503 7 . 9 8 503 8 . 0 2 503 8 . 1 1 1.4% 503 8 . 1 4 503 8 . 2 3 1.4% 503 8 . 2 5 503 8 . 3 4 1.5% 503 8 . 3 0 503 8 . 3 9 1.5% 503 8 . 5 7 503 8 . 6 6 1.5% 503 8 . 6 9 503 8 . 7 8 1.5% 503 8 . 9 0 503 8 . 9 5 0.8% 503 8 . 9 6 M E 2.0% 2.0% 0.5% 503 8 . 8 1 503 8 . 8 6 1.0%1.0% MATCH EXISTING GRADE AT PROPERTY LINE TRASH PICKUP LOCATION 1.4% 1.4% 1.4% 4.0% 503 7 . 7 9 1.6% 503 7 . 9 3 503 8 . 0 0 503 7 . 8 6 2.3% 2. 8 % 2.3 % 1.3% 1. 4 % 1. 4 % 1. 4 % 1. 4 % 3. 9 % 503 8 . 3 2 503 8 . 5 9 503 9 . 2 1 503 8 . 8 3 503 9 . 0 5 503 9 . 5 0 1. 4 % 503 9 . 0 5 503 9 . 1 0 503 9 . 5 0 5.4% 4.6% 503 9 . 5 0 4.9% 2.6% 503 9 . 3 8 503 9 . 4 8 503 8 . 8 3 503 9 . 5 0 503 9 . 5 0 503 8 . 8 3 503 9 . 5 0 503 9 . 4 1 503 9 . 5 0 503 9 . 5 0 503 9 . 5 0 503 8 . 8 3 503 8 . 8 3 503 8 . 5 5 503 9 . 1 1 503 9 . 5 0 503 9 . 5 0 503 9 . 5 0 503 9 . 5 0 FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION 1.6% 1.3% 4" S L O T T E D P V C P I P E U N D E R D R A I N 1.6% 503 8 . 8 6 503 9 . 5 0 ST0.5% 0.5% 1. 0 % ST ST ST 503 7 . 3 0 503 7 . 5 0 503 7 . 3 3 503 7 . 4 4 503 7 . 7 8 503 7 . 8 6 Pl o t t e d B y : Te d S w a n La y o u t : C4 . 0 G R A D I N G P L A N - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 7 A M Fi l e N a m e : 24 0 4 6 _ G r a d i n g P l a n . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS GRADING PLAN C4.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Grading Plan REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' GRADING PLAN LEGEND PROPERTY BOUNDARY EXISTING WATER LINE EXISTING FIRE HYDRANT EXISTING SEWER LINE EXISTING SEWER MANHOLE EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING FIBER LINE EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FIRE HYDRANT PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED SLOPE PROPOSED CONCRETE SIDEWALK PROPOSED ASPHALT ROAD PROPOSED ADA ACCESSIBLE ROUTE W FO G E 5281 5280 5281 5280 SS SS ST ST 5887.19 0.5% NOTES 1.ALL ENTRANCES ARE PRIVATE UNLESS OTHERWISE NOTED. 2.SIDEWALKS AND LANDINGS SHALL SLOPE 1.5% TOWARDS ROADS, DRIVE LANES UNLESS NOTED OTHERWISE. 3.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 4.THE MAXIMUM SLOPE WITHIN ROW IS 4:1, THE MAXIMUM SLOPE FOR PROPERTY OUTSIDE OF THE ROW IS 3:1. 5.THE SLOPE AWAY FROM THE BUILDING WITHIN LANDSCAPED AREAS SHALL BE NO LESS THAN 5% FOR THE FIRST 10' 6.THE RESULTANT GRADE IN ANY DIRECTION WITHIN ACCESSIBLE PARKING AREAS SHALL NOT EXCEED TWO PERCENT. 7.THE MAXIMUM CROSS SLOPE IN AN ACCESSIBLE PATH SHALL NOT EXCEED TWO PERCENT. THE MAXIMUM LONGITUDINAL SLOPE IN AN ACCESSIBLE PATH SHALL NOT EXCEED FIVE PERCENT. 8.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 9.ALL STORM SEWER IS PRIVATE AND WILL BE MAINTAINED BY OWNER UNLESS OTHERWISE NOTED. 10.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 5038 5038 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST WW STSTST ZERO HEIGHT CURB 503 7 . 6 2 503 8 . 1 1 503 7 . 2 7 503 7 . 2 4 503 7 . 6 4 503 7 . 7 3 503 8 . 5 8 503 7 . 8 3 503 7 . 9 7 503 8 . 1 4 503 8 . 4 3 0.8%0.5% 503 8 . 4 7 503 8 . 1 6 503 7 . 5 1 503 7 . 7 2 2. 8 % 1.3% 3. 9 % 503 8 . 3 2 503 8 . 8 3 EXTENDED DETENTION VAULT (EDB-A) (DETENTION AND WATER QUALITY ) 60" ARCH CULVERT TOTAL VOLUME = 9,400 CU FT 503 7 . 9 0 EMERGENCY OVERFLOW SPILLWAY ELEV 5037.90 WSEL 5038.10 503 7 . 7 3 503 7 . 4 2 503 7 . 8 3 503 7 . 0 7 ST ST ST 100-YR WSEL = 5037.00' WQCV WSEL = 5031.07' WQCV RESTRICTOR PLATE LENGTH 27.5" (SEE DETAIL THIS SHEET) PROPOSED GRADE 28" MIN GROUND COVER 60" ARCH CULVERT 83.63' 100-YR RESTRICTER PLATE (SEE DETAIL THIS SHEET) OUTFALL 12" RCP PIPE INV OUT: 5028.80 4" UNDERDRAIN @ 0.2% SLOPE INV AT OUTLET STRUCTURE: 50XX.XX' INV = 5028.8 PERIMETER STONE (SEE VAULT DETAIL SHEET) WQCV ORIFICE 3/4" DIA @ 12" VERT SPACING INV 5029.0 18" MIN ROCK COVER PROPOSED ACCESS MANHOLE 73.20' 12" MIN ROCK COVER 4.80" HEIGHT ABOVE PIPE INVERT 12.00" HDPE OUTLET PIPE MH OUTLET STRUCTURE MH OUTLET STRUCTURE BOTTOM OF CHAMBER = 5030.00' REFERENCE MAINTENANCE OPERATION PLAN (SEE SHEET C7.1 DETAIL) INSPECTION PORT (SEE VAULT DETAIL SHEET) PROPOSED ACCESS MANHOLE TOP MANIFOLD ADS N-12 (SEE SHEET 7.2.1 DETAIL) BOTTOM MANIFOLD ADS N-12 (SEE SHEET 7.2.1 DETAIL) INCOMING HP PIPE INV IN: 5031.08' TOP OF CHAMBER = 5035.75 100-YR RECTANGULAR RESTRICTOR PLATE WQCV RESTRICTOR PLATE 6" FROM CENTER OF MANIFOLD 4" MIN ASPHALT TOP OF WQCV PLATE: 5031.07' 24" SUMP TO BE PROVIDED IN DETENTION VAULT ENTRY MANHOLE SEE MANUFACTURER DETAILS AND CONNECTION MATERIALS ON SHEETS C7.2.0-C7.2.5 SEE MANUFACTURER DETAILS AND CONNECTION MATERIALS ON SHEETS C7.2.0-C7.2.5 BOTTOM OF ROCK = 5029.00' WQCV ORIFICE 3/4" DIA @ 12" VERT SPACING INV 5030.0 WQCV ORIFICE 3/4" DIA @ 12" VERT SPACING INV 5031.0 Pl o t t e d B y : Te d S w a n La y o u t : C7 . 0 E X T E N D E D D E T E N T I O N B A S I N P L A N - C I T Y Pr i n t e d O n : 8/ 1 8 / 2 0 2 5 3 : 3 2 A M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION VAULT PLAN C7.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 N 10'0 SCALE: 1" = 5' 5' POND PLAN LEGEND EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED GRADE GRADE AT THE TOP OF WALL GRADE AT THE BOTTOM OF WALL 5281 5280 5281 5280 ST ST POND PLAN NOTES 1.ALL STORM SHOWN ON PLAN WILL BE PRIVATELY OWNED AND MAINTAINED 2.LOOSE MATERIAL SHALL BE STORED AWAY FROM DETENTION VAULT 3.THE CONTRACTOR SHALL PREVENT ANY SEDIMENT, DEBRIS AND OTHER MATERIAL FROM ENTERING THE DETENTINO VAULT DURING AND AFTER SYSTEM INSTALLATION. 5887.19 0.5% EXTENDED DETENTION VAULT (EDB-A) GTW GBW 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 EXTENDED DETENTION BASIN WATER QUALITY VOLUME TABLE EDB WQCV(cu ft) WQ Depth (ft) 100 yr Vol (cu ft) 100 yr Depth (ft) 100 yr Outflow (cfs) A 2390.52 1.83 9345 8.0 4.11 Pl o t t e d B y : Te d S w a n La y o u t : C7 . 1 E X T E N D E D D E T E N T I O N V A U L T D E T A I L S - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 8 A M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION VAULT DETAILS C7.1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 Pl o t t e d B y : Te d S w a n La y o u t : C7 . 2 E X T E N D E D D E T E N T I O N V A U L T D E T A I L S - C I T Y Pr i n t e d O n : 8/ 1 3 / 2 0 2 5 1 0 : 0 8 A M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION VAULT DETAILS C7.1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 12345 A B C D 12345 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C o n s t r u c t i o n D e t a i l s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS CONSTRUCTION DETAILS C8.0 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N S T -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Construction Details REF PLAN ----2 3 12345 A B C D 12345 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C o n s t r u c t i o n D e t a i l s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS CONSTRUCTION DETAILS C8.1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N S T -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Construction Details REF PLAN ----2 3 BBBBB B B B B B B B B SSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST ST ST ST ST ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT ST ST ST SS SS AA 2 3 4 5 6 BB CC EE II KK DD JJ HH 1 GG A1A1 FF 4.1 UP FD VAN T WWW WWW WWW SS SS WW 0.16 AC A1 0.08 AC RA1 1 R1 0.20 AC RA2 0.93 AC A2 0.72 0.90 ST ST ST ST ST STSTST STMH-A03 4' STORM MANHOLESTINLET-A04 TYPE 16 COMBO INLET 12" PVC Pipe 12 " P V C P i p e 0.81 AC OSA R2 0.95 1.00 0.95 1.00 0.82 1.00 0.71 0.89 50 3 8 503850 3 8 503 9 503 9 5038 5038 5039 503 8 504 0 5039 504 1 5038 50 3 9 50 3 9 50 4 0 503 8 50 3 9 50 4 0 50 3 9 50 3 8 50 3 9 50 4 0 50 3 7 503 7 50 3 8 50 3 9 50 4 1 50 4 0 50 3 8 50 3 9 50 4 1 50 4 2 EXTENDED DETENTION VAULT EDB-A (DETENTION AND WATER QUALITY) EMERGENCY OVERFLOW SPILLWAY ELEV 5037.00 WSEL 5037.15 4' CONCRETE PAN OFFSITE STORMWATER FLOWS LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC OFFSITE STORMWATER FLOWS OFFSITE STORMWATER FLOWS OFFSITE STORMWATER FLOWS OFFSITE STORMWATER FLOWS BUILDING FFE: 5039.50 BUILDING FFE: 5039.50 OFFSITE STORMWATER FLOWS FROM EASTERN PARKING LOT - ASSUMED FULL FLOW FOR PIPE 0.83 CFSST 12 " P V C P i p e 12" PVC Pipe 24" HDPE Pipe ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST 2 3 4 STMH-A02 4' STORM MANHOLE 8" PVC Pipe STINLET-A01 DOUBLE TYPE 16 VALLEY INLET STINLET-A01.1 24" NYLOPLAST STORM BASIN Storm Cleanout Storm Cleanout 8" BEND CONNECT TO BLDG CLEANOUT (RE PLUMBING FOR CONTINUATION) Storm Cleanout 12 " P V C P i p e 8" P V C P i p e 8" PVC Pipe 12 " P V C P i p e 12" PVC Pipe12" PVC Pipe 4" S L O T T E D P V C P I P E Storm Cleanout 8" PVC Pipe 12"X12" TEE W/ 12"X8" REDUCER CONNECT TO BLDG CLEANOUT (RE PLUMBING FOR CONTINUATION) STMH-B03 4' MANHOLE VAULT OUTLET STRUCTURE 12" PVC Pipe STMH-B02 4' STORM SYPHON MANHOLE WITH PERFORATED BASE STMH-B01 4' STORM MANHOLE 12" PVC Pipe 12"X12" TEE 50 3 9 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ D r a i n a g e P l a n . d w g N 40'0 SCALE: 1" = 20' 20' NOTES 1.ALL STORM INFRASTRUCTURE SHOWN IS PRIVATE UNLESS OTHERWISE NOTED AND WILL BE MAINTAINED BY THE PROPERTY OWNER - VOLUNTEERS OF AMERICA. STORM INFRASTRUCTURE HAS BEEN DESIGNED TO ACCOMMODATE THE 100 YEAR STORM 2.BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM)IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM 5031.12’. DRAINAGE PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED RETAINING WALL BASIN DELINEATION FLOW ARROW BASIN LABEL DESIGN POINT LABEL 5281 5280 5281 5280 ST ST XX XX XX XX BASIN ID AREA 2 YR C-VALUE XX EXTENDED DETENTION BASIN WATER QUALITY VOLUME TABLE EDB WQCV(cu ft) WQ Depth (ft) 100 yr Vol (cu ft) 100 yr Depth (ft) 100 yr Outflow (cfs) A 2390.52 1.83 9345 8.0 4.11 100 YR C-VALUE 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS DRAINAGE PLAN DR1 TS 24046 08/08/2025 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N ST -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Drainage Plan REF PLAN ----2 3