HomeMy WebLinkAboutPlans - Irrigation Plan - 08/06/2025SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER RZWS-18-CV 18IN. LONG RZWS WITH INSTALLED NO BUBBLER. INSTALL WITH CHECK VALVE, 1/2IN. SWING JOINT FOR CONNECTION TO 1/2IN. PIPE. INSTALL WITH RAINBIRD XB-05PC EMITTER PER DETAILS. 30 SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL DRIP VALVE ASSEMBLY RAIN BIRD XCZ-100-PRB-COM: WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM DRIP FLUSH VALVE 3/4" SCH 40 OR SCH 80 PVC BALL VALVE PER DETAILS SYMBOL MANUFACTURER/MODEL/DESCRIPTION QUICK COUPLER ASSEMBLY RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH CORROSION-RESISTANT STAINLESS STEEL SPRING, THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY. ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. REDUCED PRESSURE BACKFLOW PREVENTER EXISTING BY OTHERS. NOTED FOR REFERENCE. PEDESTAL MOUNT CONTROLLER HUNTER P2C-400: LIGHT COMMERCIAL & RESIDENTIAL CONTROLLER, 4-STATION BASE MODULE CONTROLLER, 120 VAC, OUTDOOR/INDOOR MODEL. MOUNT ON 4X4 REDWOOD/CEDAR POST WITH RAIN SENSOR. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED. IRRIGATION MAINLINE: PVC SCHEDULE 40 PIPE SLEEVE: PVC SCHEDULE 40 INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL SHARE THE SAME SLEEVE. A Valve Number Valve Flow Valve Size Valve Callout # ##" IRRIGATION SCHEDULE EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. 3.REFER TO PROVIDED LANDSCAPE PLANS FOR PLANT TYPES AND SIZES. INSTALL EMITTERS PER PLANT WATER REQUIREMENT. CODE DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE AT THE APPROX. LOCATION SHOWN. IRRIGATION BACKFLOW SHALL BE INSTALLED BY OTHERS (REFER TO MECHANICAL DRAWINGS) INSIDE MECHANICAL ROOM, UPSTREAM OF DOMESTIC BACKFLOW. MAKE MAINLINE CONNECTION TO EXISTING COPPER STUB AT THE APPROX. LOCATION SHOWN. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE. 1 2 REFERENCE NOTES SCHEDULE INSTALLATION GENERAL NOTES 1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION SYSTEM (NOT OBTAINED) OF 80 PSI, AT A MAXIMUM PEAK FLOW OF 10 GPM AT THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 1.1.IRRIGATION IS CONNECTED DOWNSTREAM OF THE 1-INCH DOMESTIC METER AS INDICATED. IRRIGATION IS DESIGNED TO UTILIZE ONLY 10 GPM. 2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL SPRINKLERS MAY BE REQUIRED. 8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN WITHIN THE 3'-5' RANGE NOTED ABOVE. 9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 14.INSTALL THREE (3) #14 AWG CONTROL WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE FOR USE AS SPARES INCASE OF CONTROL WIRE FAILURE. COIL 3 FEET OF WIRE IN VALVE BOX. 15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. 19.CONTRACTOR SHALL PROVIDE SMART CONTROLLER CHART, PER LOCAL WATER DISTRICT OR MUNICIPALITY, INSIDE CONTROLLER DOOR. DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 0 Pr i n t e d O n : 7/ 3 1 / 2 0 2 5 1 1 : 2 8 A M Fi l e N a m e : IR - 3 0 0 E M T . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N RIPLEY DESIGN INC. Klara Rossouw 236 Linden Street, Suite A Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT LANDSCAPE ARCHITECT / LAND PLANNER EPS GROUP Blaine Mathisen 301 N Howes St #100 Fort Collins, CO 80521 p. 970.221.4158 VFLA ARCHITECTS Chris Aronson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 236 Linden Street, Suite A Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com MOUNTAIN 300, LLC 262 E. Mountain Ave Fort Collins, CO 80524 p. 970.490.2626 OWNER/APPLICANT 1 BDR SUBMITTAL #2 04/02/2025 2 BDR SUBMITTAL #3 08/06/2025 IRRIGATION LEGEND AND NOTES BASIC DEVELOPMENT REVIEW 300 EAST MOUNTAIN AVENUE FORT COLLINS, CO KR + TB HJ R24-002 NORTH 0 05 10 20 SCALE: 1"=10'-0" 300 EAST MOUNTAIN AVENUE BASIC DEVELOPMENT REVIEW IR1.0 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com FD C E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E 1" CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COM M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS SS SS SS ST ST ST ST ST STST ST ELE C BRK R G F.O. C.O.V.P. C SC S WV WV D D SS SS SS SS G WV WV G ELE C T T F.O. VAULT ELEC G ELEC S S SS SS SS SS SS SS SS SS CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COM M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS SS SS SS ST ST ST ST ST STST ST ELE C BRK R G F.O. C.O.V.P. C SC S WV WV D D SS SS SS SS G WV WV G ELE C T T F.O. VAULT ELEC G ELEC S S SS SS SS SS SS SS SS SS CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COM M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS SS SS SS ST ST ST ST ST STST ST ELE C BRK R G F.O. C.O.V.P. C SC S WV WV D D SS SS SS SS G WV WV G ELE C T T F.O. VAULT ELEC G ELEC S S SS SS SS SS SS SS SS SS G G G G G G G G G G G G G G T TRAFFIC VAULT VAULT ELEC CONTROL IRR CONTROL IRR E E E E E E E E E E E E E IR R IR R G G G G G G G G G G G G G G T TRAFFIC VAULT VAULT ELEC CONTROL IRR CONTROL IRR E E E E E E E E E E E E E IR R IR R M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COM M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST SS SS SS SS SS ST ST ST ST ST STST ST ELE C BRK R G F.O. C.O.V.P. C SC S WV WV D D SS SS SS SS G WV WV G ELE C T T F.O. VAULT ELEC G ELEC S S SS SS SS SS SS SS SS SS POC NO.1 IRRIGATION SERVICE LINE SIZE: 1.25-INCH PEAK DEMAND: 10 GPM AVAILABLE PRESSURE: 80 PSI+/- CONTROLLER 'A' 120 VAC POWER REQUIRED IRRIGATION BACKFLOW (BY OTHERS): 3/4-INCH A (2)3" (2)3" (2)3" (2)3" (2)3" (2)3" 1 2 IRRIGATION PULL BOX PER DETAILS (2)3" (2)3" DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 1 Pr i n t e d O n : 7/ 3 1 / 2 0 2 5 1 1 : 2 8 A M Fi l e N a m e : IR - 3 0 0 E M T . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N RIPLEY DESIGN INC. Klara Rossouw 236 Linden Street, Suite A Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT LANDSCAPE ARCHITECT / LAND PLANNER EPS GROUP Blaine Mathisen 301 N Howes St #100 Fort Collins, CO 80521 p. 970.221.4158 VFLA ARCHITECTS Chris Aronson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 236 Linden Street, Suite A Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com MOUNTAIN 300, LLC 262 E. Mountain Ave Fort Collins, CO 80524 p. 970.490.2626 OWNER/APPLICANT 1 BDR SUBMITTAL #2 04/02/2025 2 BDR SUBMITTAL #3 08/06/2025 IRRIGATION PLAN BASIC DEVELOPMENT REVIEW 300 EAST MOUNTAIN AVENUE FORT COLLINS, CO KR + TB HJ R24-002 NORTH 0 05 10 20 SCALE: 1"=10'-0" 300 EAST MOUNTAIN AVENUE BASIC DEVELOPMENT REVIEW IR1.1 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 2 Pr i n t e d O n : 7/ 3 1 / 2 0 2 5 1 1 : 2 8 A M Fi l e N a m e : IR - 3 0 0 E M T . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N RIPLEY DESIGN INC. Klara Rossouw 236 Linden Street, Suite A Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT LANDSCAPE ARCHITECT / LAND PLANNER EPS GROUP Blaine Mathisen 301 N Howes St #100 Fort Collins, CO 80521 p. 970.221.4158 VFLA ARCHITECTS Chris Aronson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 236 Linden Street, Suite A Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com MOUNTAIN 300, LLC 262 E. Mountain Ave Fort Collins, CO 80524 p. 970.490.2626 OWNER/APPLICANT 1 BDR SUBMITTAL #2 04/02/2025 2 BDR SUBMITTAL #3 08/06/2025 IRRIGATION DETAILS BASIC DEVELOPMENT REVIEW 300 EAST MOUNTAIN AVENUE FORT COLLINS, CO KR + TB HJ R24-002 NORTH 0 05 10 20 SCALE: 1"=10'-0" 300 EAST MOUNTAIN AVENUE BASIC DEVELOPMENT REVIEW IR1.2 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com ISOLATION GATE VALVE ASSEMBLY3 QUICK COUPLING VALVE ASSEMBLY4 REMOTE CONTROL DRIP VALVE ASSEMBLY6 SINGLE OUTLET EMITTER ASSEMBLY7 PEDESTAL MOUNT CONTROLLER ASSEMBLY1 A ROOT WATERING BUBBLER ASSEMBLY5 18" ROOT ZONE WATERING SYSTEM PER PLAN (1 OF X) PER PLAN FINISH GRADE LATERAL PIPE - SIZE PER PLANROOT BALL NOTES INSTALL RZWS SLEEVE OVER TUBE TO HELP PREVENT SOIL INTRUSION REFER TO LANDSCAPE PLAN FOR TREE PLANTING DETAIL DRIP FLUSH CAP ASSEMBLY8 TYPICAL PULL BOX INSTALLATION2