Loading...
HomeMy WebLinkAboutReports - Drainage - 08/06/2025FINAL DRAINAGE REPORT GILMARTIN SUBDIVISION 341 SOUTH TAFT HILL ROAD FORT COLLINS, COLORADO Project Number FDP250005 Prepared for Evan Gilmartin Owner Prepared by Sorensen Engineering & Construction, Inc. 1901 Bear Court Fort Collins, CO August 2025 1901 Bear Court / Fort Collins, Colorado 80525 (970) 590-1579 / paul@secengineering.net Sorensen Engineering & Construction, Inc. Civil/Environmental Engineering August 6, 2025 City of Fort Collins Stormwater Development Review Engineer 222 Laporte Ave. Fort Collins, CO 80524 Subject: PDP/FP Drainage Report Gilmartin Subdivision 341 South Taft Hill Road Larimer County Parcel No. 9709404005 Project Number FDP250005 Dear City of Fort Collins Stormwater, On behalf of Evan Gilmartin, owner of the referenced property, Sorensen Engineering & Construction, Inc. (SEC – the “Design Engineer”) is pleased to submit this Final Drainage Report for the proposed Gilmartin Subdivision. This Drainage Report follows the City of Fort Collins Stormwater Criteria Manual (FCSCM) PDP/FP Drainage Report Checklist. STATEMENT OF COMPLIANCE: The Applicant commits that all erosion control measures that are provided with the final plans will be implemented. This Final Drainage Report complies with the Fort Collins Stormwater Criteria Manual and floodplain regulations. Please do not hesitate to contact me directly if you have any questions or concerns regarding this Final Drainage Report, or if you require any additional information. Respectfully, Paul C. Sorensen, PE Attachments 3 “I hereby attest that this report for the final drainage design for the Gilmartin Subdivision was prepared by me or under my direct supervision, in accordance with the provisions of the Fort Collins Stormwater Criteria Manual. I understand that the City of Fort Collins does not and will not assume liability for drainage facilities designed by others.” Paul C. Sorensen, PE 8/06/2025 4 Sorensen Engineering & Construction, Inc. (SEC) is pleased to submit this Final Drainage Report for the proposed Gilmartin Subdivision. This Final Drainage Report is prepared in accordance with the City of Fort Collins Stormwater Criteria Manual. I. GENERAL LOCATION & EXISTING SITE INFORMATION As shown on Figure 1, Vicinity Map, the site is located at 341 South Taft Hill Road, Fort Collins, Colorado. The site is located in the SE ¼, Section 9, Township 7 North, Range 69 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. The project site is located in the Mulberry Hill neighborhood and is bordered to the north by an existing single-family residential property, to the east by South Taft Hill Road and City Park Golf Course, to the west by single-family homes (Mulberry Hill) and Poudre High School, and to the south by single family homes (Mulberry Hill) and a church, and Mulberry Street. The site is currently covered with native grasses, with approximately 80% vegetative cover. The Site is located in the Canal Importation Basin. There are no existing stormwater drainage facilities on the subject property. The site is relatively flat, with existing drainage patterns flowing gently from west to east. The New Mercer Ditch is pres ent about ¼-mile to the east; running through the City Park Nine golf course. As shown on Figure 2, Existing Conditions and Demolition Plan, the Site is currently vacant ground with native grasses and weeds across the property. As required, a Floodplain Use Permit will be acquired prior to any construction activities on the subject site. Additionally, in accordance with City of Fort Collins comments, the following notes shall apply: 1) This property is currently located in the city regulated, 100-year Canal Importation flood fringe and must comply with the safety regulations of Chapter 10 of City Municipal Code (in fact, the entire property lies within the 100-year Canal Importation Flood Fringe area). 2) Any construction activities in the flood fringe (e.g. structures, sidewalk or curb & gutter installation/replacement, utility work, landscaping, etc.) must be preceded by an approved floodplain use permit, the appropriate permit application fees, and approved plans. 3) The lowest finished floor elevation of a new residential structure, and all duct work, heating, ventilation, electrical systems, etc. must be elevated 18 inches above the highest Base Flood Elevation (BFE) within the footprint of the structure. 4) Any new crawl space must comply with venting and crawl space requirements from Sections 10 39 and 10 40 of City Municipal Code.” The NRCS Custom Soil Resource Report for the site is provided herein in Appendix A. As shown, the on-site soil is primarily a Nunn clay loam at 1 to 3% slope with a small section on the west side of the lot (west of the future Pennsylvania ROW) consisting of Altvan-Satanta loams at 0 to 3% slope. The entire area for this proposed project lies within the Nunn clay loam soils with a Hydrologic Soil Group C. 5 II. MASTER DRAINAGE BASIN INFORMATION This project is located in the Canal Importation Basin in Fort Collins. The Canal Importation Basin encompasses almost five square miles (3,200 acres) of west-central Fort Collins. The basin is bounded generally by Laporte Avenue on the north, the foothills on the west, Drake Road to the south and extends almost to Shields Street on the east. Across the basin, a 100 -year storm event could lead to flood-related damage to homes and other structures. There are no master planning improvements on or adjacent to the site. Historic drainage patterns within the basin are from west to east. There have been significant precipitation and flood events over the last 100 years that have caused property damage w ithin the basin. There are no irrigation ditches, reservoirs, or other facilities that influence or are influenced by the local drainage. III. FLOODPLAIN INFORMATION The project property lies within the City of Fort Collins 100-year Canal Importation Basin Flood Fringe. The flood fringe area is relatively flat, sloping gently from west to east. IV. PROJECT DESCRIPTION As shown on Figure 3, Overall Site Plan, the proposed project contains approximately 0.71 acres; including the following characteristics: • Lot One for a single-family home with a detached additional dwelling unit (ADU): .60+/- acre (excludes the Pennsylvania Street ROW); • Dedication of Pennsylvania Street: .09 acre; • Outlot: .15 acre; • Dedication of Additional Public Right-of-Way for S. Taft Hill Road (Two-Lane Arteria): 12’; and • Dedication of Utility Easement along S. Taft Hill Road: 15’ V. PROPOSED DRAINAGE FACILITIES The project site is currently vacant, covered with grass and weed vegetation, with approximately 2% impervious area. Drainage patterns are from west to east across the site, discharging in general via sheet flow to S. Taft Hill Road. No existing improvements are found on the subject property. Proposed site improvements and specific water quality (Low Impact Development – LID) measures include the following: • A total estimated area of disturbance, including a staging area on the west side of the proposed home and ADU buildings is approximately 26,163 square feet (0.60 acres) (the disturbed area is limited to Lot 1); 6 • Construction of the access driveway along the north side of the subject property. The driveway will be constructed of concrete. The driveway will encompass an approximate area of 150-feet long by 12-feet wide (1,800-sf). Additional gravel or recycled asphalt surface will include the parking area on the west side of the home and ADU of approximately 50-ft x 50-ft (2,500 sf), for a total area of approximately 4,300 square feet (sf), or 0.10 acres(ac); • One single family home, with a building footprint of 35-feet x 60-feet (2,100 sf), plus one ADU with a building footprint of 25-feet x 40-feet (1,000 sf), including area within that footprint for a 10-ft x 10-ft “room” for the fire suppressant sprinkler system tank and pump for a total rooftop area of 3,100-sf (0.07 AC); • Direct building downspouts into landscaped areas; • Site grading will be accomplished to provide disconnection of impervious areas to the extent possible; • Flood vents will be installed in the foundation walls of both structures. Vents are sized to provide 1 square inch of opening per 1 square foot of floor space; and • The remaining portions of the subject property will be landscaped with grass and plantings or remain as native, undisturbed grass. As indicated above, this site is in the Fort Collins Canal Importation Basin. Figure 4, City of Fort Collins Flood Risk Map, provides the corresponding flood map, showing the City-provided 100-year flood fringe depth of flow across the site. Figure 5, Grading and Drainage Plan presents details of the proposed drainage facilities for this project. As shown, the proposed structures are structurally independent and are elevated so that the lowest floor, including HVAC ductwork, is at least 18-inches above the 100-year Base Flood Elevation (BFE) as defined. The basic drainage plan for this project is to minimize grading and maintain the existing drainage pattern: sheet flow across the property from west to east. As shown on Figure 6, Erosion Control and Floodproofing Plan, flood vents will be installed in the upstream and downstream sides of both the proposed ADU and single family home foundations to allow flood water to flow via its natural course unobstructed by the structures, thence discharging via sheet flow across landscaped areas into the curb and gutter flow in Taft Hill Road and flowing to the existing storm sewer inlet south of the site along the west side on Taft Hill Road. The flood vents will be sized to provide at least 1-square inch of vent area per 1- square foot of floor area, and the crawlspace in each unit will be graded to promote flood water drainage following a major precipitation event. One sump pump shall be installed near the downstream (east) side of each structure to ensure complete evacuation of runoff water following major precipitation events. Off-site flow to adjacent properties will be mitigated by grading to direct flow from the west side of the proposed housing structures to the inverted crown driveway, and thence to S Taft Hill Road. Maintenance access for drainage facilities associated with this project shall remain open as nay be needed. 7 VI. DRAINAGE DESIGN CRITERIA a. Four-Step Process Management of runoff from frequently occurring storm events shall include consideration of the following four step process that may be applicable for this project: i. Employ runoff reduction practices: With the exception of building footprints, the concrete driveway and the gravel/recycled asphalt parking area, the remainder of the site will retain in pervious nature, allowing for most precipitation from small, frequent events to infiltrate on-site. The relatively flat nature of this site does not encourage off-site runoff from small, more frequent precipitation events. Site grading and landscaping will serve to minimize small precipitation event runoff. ii. Implementing best management practices (BMPs) that provide a water quality capture volume with slow release and/or infiltration : This process in not applicable for this site; no detention storage is required, therefore consideration of the Water Quality Capture Volume (WQCV) is not applicable. iii. Stabilizing Streams: This process is also not applicable for this site – no streams are present on the site or adjacent to the site. iv. Implementing site specific and other source control BMPs: Site-specific BMPs to be implemented at this site include the following (discussed in detail below in the “Erosion and Sediment Control” section of this Drainage Report): 1. Silt Fencing 2. Vehicle Tracking Pad 3. Concrete Washout Pit 4. Sediment Straining 5. Controlled Staging Area 6. Stockpile Management b. Rainfall Data CoFC rainfall data are used for the 2-year and 100-year storm events. Rainfall runoff data used are as described in the Fort Collins Stormwater Criteria Manual (FCSCM), Chapter 5, Table 3.4- 1. The “minor storm” analysis is the 2-year event, and the “major storm” even is the 100-year event. The 2-year drainage system is designed to transport stormwater runoff from the site with minimal disruption to neighbors or the urban environment. This minor storm runoff will be conveyed in the curb and gutter of Taft Hill Road to the nearby storm sewer inlet. The 100 -year drainage system is designed to eliminate the loss of life and to minimize adjacent property damage and to convey runoff to the Taft Hill curb and gutter and thence to the storm sewer inlet. The hydrologic calculations for this drainage investigation are based on the historic and proposed (composite) runoff coefficients as described in FCSCM Chapter 5, Table 3.2-2 as shown in Table 1. The runoff analysis discussed below uses runoff coefficients that employ the Frequency Adjustment Factors as presented in Table 3.2-3 for respective storm frequencies. For this very small project, the runoff coefficient presented below is for the entire site as a single basin. 8 Calculations of the composite runoff coefficients are included in Appendix B, Hydrologic Calculations. Table 1. Existing and Proposed Composite Runoff Coefficients Total Drainage Area = 0.71 Acres = 30,809 square feet (sf) Surface Cover/Use Defined Runoff Coefficient1 Area (sf) Historical/Existing Proposed Historical Flow Analysis (undeveloped clay-loam soil type) 0.20 30,809 0 Parking area (gravel) 0.50 0 2,500 Driveway (concrete) 0.95 2,400 Rooftop 0.95 0 3,100 Undisturbed soil (assume 2% slope) 0.20 0 15,000 Landscape/grasses (assume 2% slope) 0.20 0 7,809 Historical Runoff Coefficienti 0.20 Proposed Runoff Coefficient 0.36 1. Reference: FCSCM Chapter 5, Table 3.2-2 c. Runoff Calculation Method The Rational Method is used to calculate both the minor and major runoff events. The one-hour point rainfall depth used for the 2-year event is 0.82 inches and for the 100-year event is 2.86 inches (FCSCM Chapter 5, Table 3.4-1). The hydrological analysis was computed using the Peak Runoff Prediction by the Rational Method spreadsheet developed by the Urban Drainage and Flood Control District (now the Mile High Flood District - MHFD) as described in the Urban Storm Drainage Criteria Manual (USDCM), Volume 1. The MHFD model allows for user override to enter the runoff coefficients presented above as well as Fort Collins -specific rainfall depths as presented in the aforementioned Table 3.4-1. The Rational Method is used to analyze the existing and fully developed conditions . The Hydrologic Calculations are presented in Appendix B, the results of which are summarized in Table 2. 9 Table 2. Results of Peak Runoff Flow Prediction by the Rational Method Basin Runoff Coefficients Peak Runoff Flowrate (cfs) Existing Developed Existing Developed 2-yr 100-yr 2-yr 100-yr 2-yr 100-yr 2-yr 100-yr Project 0.20 0.25 0.36 0.45 0.19 0.83 0.44 1.93 As is demonstrated above, the proposed site improvements will increase the estimated peak runoff flowrate from 0.19 to 0.44 cfs for the 2-year event, and from 0.83 to 1.93 cfs for the 100- year event. This increase in runoff is typical of small projects like this and would not contribute to off-site impacts during a large precipitation event. d. Detention Calculation Method – not applicable; detention storage is not required for this project. VII. VARIANCE REQUESTS There are no variance requests with this project. VIII. EROSION AND SEDIMENT CONTROL PLAN Proposed ground disturbance on this lot will basically be limited to the new access driveway and for the construction of two new residential structures. Erosion control measures to be implemented include the following: • Silt fencing shall be placed along the property perimeter to control off-site stormwater and sediment runoff. • Vehicle Tracking Pad shall be placed at the proposed new access point off of Taft Hill Road near the northeast corner of the lot. • Concrete Washout Pits shall be placed adjacent to the new home construction sites. The specific locations shall be determined by the building contractor. • Sediment Straining will occur naturally with the maintenance of existing native grasses along most of the western half of the property. With construction activities limited to the central and eastern portion of the property, the natural grass buffer will filter runoff as it flows across the existing native grasses, effectively straining and providing physical removal or retention of particulates from the runoff. • Controlled staging area shall be placed on the site and coordinated by the building contractor; • Stockpile management shall be exercised. This project entails minimal dirt moving activities; site grading will be minimal, and because no basements are allowed, excavated materials will be minimal as well. However, any dirt stockpile that is required will be managed and controlled in accordance with good housekeeping and best professional judgement. 10 Disturbed areas of the project that will remain uncompacted and will be revegetated with native grasses. Figure 6, Erosion Control and Floodproofing Plan presents details of the proposed BMPs to be implemented, as summarized above. IX. CONCLUSIONS This Drainage Narrative was prepared in accordance with the Fort Collins Stormwater Criteria Manual. As is demonstrated above, the proposed site improvements will increase the estimated peak runoff flowrate from 0.19 to 0.83 cfs for the 2-year event, and from 0.44 to 1.93 cfs for the 100-year event. SEC believes that the increase in peak runoff flowrates will not impact adjacent properties. The drainage plan as herein described was prepared in accordance with sound engineering practices and with Best Professional Judgement and provides an effective drainage system for this site that will effectively control stormwater runoff from this property and not exacerbate flood-related damage to neighboring or downstream properties. STATEMENT OF COMPLIANCE: The Applicant commits that all erosion control measures that are provided with the final plans will be implemented. This Final Drainage Report complies with the Fort Collins Stormwater Criteria Manual and floodplain regulations. 11 REFERENCES 1. City of Fort Collins Stormwater Criteria Manual, Chapter 5, Hydrology Standards, December 2018. 2. City of Fort Collins Flood Risk Map, February 2, 2022. 3. National Resources Conservation Service (NRCS) Custom Soil Resources Report for Larimer County Area, Colorado, 341 Southy Taft Hill Road, March 16, 2023. 4. Urban Drainage and Flood Control District, a.k.a., Mile High Flood District (MHFD), Peak Runoff Prediction by the Rational Method, Version 2.00 released May 2017. CONTOUR INTERVAL: 10 FEET PROJECT DATE: FEBRUARY 2022 MAP SOURCE: USGS FORT COLLINS, COLO 2016 LARIMER COUNTY PARCEL NUMBER: 9709404005 341 S Taft Hill Rd Fort Collins, CO FIGURE 1 VICINITY MAP PROJECT SORENSEN ENGINEERING & CONSTRUCTION, INC CIVIL / ENVIRONMENTAL ENGINEERING 1901 BEAR COURT FORT COLLINS, CO 80525 PHONE:970 590-1579 paul@secengineering.net N Scale in Miles 0 11/2 PROPERTY LOCATION 50 7 5 50 7 6 50 7 4 50 7 3 507 2 5071 50 7 0 50 7 1 50 7 0 507650 7 6 5077 5077 507 7 50 7 8 adjacent house adjacent garageadj shedadjacent building SO U T H T A F T H I L L R O A D XS # . 1 0 7 9 5 0 7 0 . 7 2 f t N A V D 8 8 XS # . 1 0 1 1 5 0 6 8 . 7 2 f t N A V D 8 8 XS # . 1 4 7 7 5 0 7 5 . 9 4 f t N A V D 8 8 LOT 1 26162.75 Sq. Ft. 0.60 Acres OUTLOT (EXIST GRADES/VEGETATION TO REMAIN UNDISTURBED) QU I T C L A I M - R E C . NO . 2 0 0 7 0 0 1 5 2 3 5 42.00' PR O P E R T Y B O U N D A R Y EXISTING ACCESS TO BE REMOVED AND REPLACED WITH NEW CURB, GUTTER, AND SIDEWALK TO MATCH EXISTING (see detail drawing 701, Sheet U105) 0 40 20 N o r t h - S c a l e 1 " = 2 0 ' SEAL DRAWN BY: PS PAS CHECKED BY: SHEET NUMBER: SCALE: DATE: 08/04/25 SHEET INDEX: JOB NUMBER: RE V I S I O N S PR O J E C T NO . DA T E DE S C R I P T I O N FO R T C O L L I N S , C O L O R A D O SH E E T T I T L E SO R E N S E N E N G I N E E R I N G & C O N S T R U C T I O N , I N C CI V I L / E N V I R O N M E N T A L E N G I N E E R I N G 19 0 1 B E A R C O U R T FO R T C O L L I N S , C O 8 0 5 2 5 PH O N E : 9 7 0 5 9 0 - 1 5 7 9 pa u l @ s e c e n g i n e e r i n g . n e t 34 1 S O U T H T A F T H I L L R O A D EX I S T I N G C O N D I T I O N S A N D D E M O L I T I O N P L A N AS NOTED FIG 2 GILMARTIN MINOR SUBDIVISION A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 9, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO 341 SOUTH TAFT HILL ROAD FORT COLLINS, COLORADO LARIMER COUNTY PARCEL # 9709404005 adjacent house adjacent garageadj shedadjacent building SO U T H T A F T H I L L R O A D Se w e r Se w e r Storm Sewer LOT 1 26162.75 Sq. Ft. 0.60 Acres BUILDING ENVELOPE PRINCIPAL RESIDENCE OUTLOT (EXISTING GRADES/VEGETATION TO REMAIN UNDISTURBED) QU I T C L A I M - R E C . NO . 2 0 0 7 0 0 1 5 2 3 5 PENNSYLVANIA STREET 57' RIGHT OF WAY 30.00' 42.00' 15.00' 30.00' 12.00' UTILITY EASEMENT SETBACK PR O P E R T Y B O U N D A R Y 60' Parking Spaces (10'x20') Recycled Asphalt / Road Base Front door facing S Taft Hill Road 35' 2100 sf GRAVEL OR RECYCLED ASPHALT 10' ADU - DETACHED 25' 40' 1000 sf 5' SETBACK (min)139' Penn St to ADU 139' CONRETE ALLEY 4' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 0 40 20 N o r t h - S c a l e 1 " = 2 0 ' SEAL LANDSCAPE SCHEDULE DRAWN BY: PS PAS CHECKED BY: SHEET NUMBER: SCALE: DATE: 07/31/2025 SHEET INDEX: JOB NUMBER: RE V I S I O N S PR O J E C T NO . DA T E DE S C R I P T I O N FO R T C O L L I N S , C O L O R A D O SH E E T T I T L E SO R E N S E N E N G I N E E R I N G & C O N S T R U C T I O N , I N C CI V I L / E N V I R O N M E N T A L E N G I N E E R I N G 19 0 1 B E A R C O U R T FO R T C O L L I N S , C O 8 0 5 2 5 PH O N E : 9 7 0 5 9 0 - 1 5 7 9 pa u l @ s e c e n g i n e e r i n g . n e t 34 1 S O U T H T A F T H I L L R O A D OV E R A L L S I T E P L A N A N D L A N D S C A P I N G P L A N AS NOTED QTY 3 SYMBOL BOTANIC NAME COMMON NAME SIZE 2 ULMUS DAVIDIANA JAPONICA "DISCOVERY" PINU EDULIS DISCOVERY ELM PINYON PINE 2.5" CAL. MIN 6' HT LANDSCAPING NOTES: COVER IN LANDSCAPE AREAS - ALL REQUIRED LANDSCAPED AREAS MUST CONTAIN A MINIMUM OF SEVENTY FIVE PERCENT (75%) ORGANIC MATERIAL, WITH A MAXIMUM OF TWENTY FIVE (25%) NON-LIVING MATERIALS. MIN. SIZE FOR TREES AND SHRUBS - ORNAMENTAL, LESS THAN 20' MATURITY HEIGHT. 1"-1.5" CAL. SIZE AT PLANTING GRADING STANDARD - LAWN AND GRASSED AREAS, MAX SLOPE 4:1 MAINTENANCE STANDARDS - ALL LANDSCAPING AND REQUIRED BUFFERING SHALL BE CONTINUALLY MAINTAINED INCLUDING IRRIGATION IF APPLICABLE, WEEDING, PRUNING, AND REPLACING IN A SUBSTANTIALLY SIMILAR MANNER AS ORIGINALLY APPROVED. THE FOLLOWING SURVIVAL STANDARDS SHALL APPLY TO ALL LANDSCAPING AND REQUIRED BUFFERS: 1. LIVING GROUND COVERS: LIVING GROUND COVERS MUST BE FIFTY PERCENT (50%) ESTABLISHED AFTER THE FIRST GROWING SEASON,, AND NINETY PERCENT (90%) ESTABLISHED THEREAFTER. 2. NON-LIVING GROUND COVERS: NON-LIVING GROUND COVERS, SUCH AS ROCK OR MULCH MUST BE ONE HUNDRED PERCENT (100%) INTACT AFTER ONE (1) YEAR AND EIGHTY PERCENT (80%) INTACT THEREAFTER. 3. TREES AND SHRUBS: TREES AND SHRUBS MUST HAVE A ONE HUNDRED PERCENT (100%) SURVIVAL RATE AFTER ONE (1) YEAR AND A NINETY PERCENT (90%) SURVIVAL RATE THEREAFTER. ALL DIMENSIONS AND LOCATIONS ARE ASSUMED AND SHOW DESIGN INTENT ONLY, VERIFY IN FIELD. PROPERLY PREPARE SOILS FOR NEW PLANTINGS. PROVIDE GOOD BALANCE OF AIR, SAND, SILT, AND CLAY. USE WOVEN FABRIC WEED BARRIERS AS DESIRED. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS, AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUBS BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. COST NOTES: XERISCAPE CONVERSION TYPICALLY RUNS AT $1.50 - $4.50 PER/SF FOR MATERIAL AND PLANTS. LABOR NOT INCLUDED. OTHER COSTS WOULD INCLUDE THE REMOVAL OF EXISTING MATERIAL FROM THE SITE, ANY NECESSARY SOIL AMENDMENT AND ANY TREES/SHRUBS REQUIRED. THE DEVELOPER OR ITS SUCCESSOR(S) SHALL BE RESPONSIBLE FOR THE ONGOING IRRIGATION AND MAINTENANCE OF THE LANDSCAPING LOCATED WITHIN TEH PUBLIC RIGHT OF WAY ALONG THE PORTION OF S TAFT HILL ROAD THAT ABUTS THE DEVELOPMENT. NOT FOR CONSTRUCTION FIG 3 GILMARTIN MINOR SUBDIVISION NOTE: THE BUILDING DESIGN SHALL MEET THE ZONE DISTRICT AND BUILDING TYPE STANDARDS AS OUTLINED IN SECTION 2.2.1 AND DIVISION 3.1 NOTE: AT THE TIME PENNSYLVANIA STREET IS FULLY IMPROVED AS A RESIDENTIAL LOCAL STREET (LCUASS 7-8F), ALONG THE ENTIRE FRONTAGE OF THE GILMARTIN SUBDIVISION, WITH PENNSYLVANIA STREET ACHIEVING CONNECTIVITY TO THE ADJACENT PUBLIC STREET SYSTEM, AND IN COMPLIANCE WITH ALL REQUIREMENTS OF THE POUDRE FIRE AUTHORITY. THE EXISTING DRIVEWAY AT SOUTH TAFT HILL ROAD SHALL BE CLOSED AND ACCESS TO THE GILMARTIN SUBDIVISION SHALL THEN BE GAINED VIA PENNSYLVANIA STREET. XS # : 1 0 1 1 5 0 6 8 . 7 2 f t N A V D 8 8 XS # : 1 0 4 6 5 0 7 0 . 4 4 f t N A V D 8 8 XS # : 1 0 7 9 5 0 7 0 . 7 2 f t N A V D 8 8 XS # : 1 1 9 5 5 0 7 1 . 5 9 f t N A V D 8 8 XS # : 1 4 7 7 5 0 7 5 . 9 4 f t N A V D 8 8 S T A F T H I L L R D W MULBERRY ST Printed: 02/02/2022. All floodplain boundaries are approximate. This information is based on the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map (FIRM) and the City of Fort Collins Master Drainageway Plans. This letter does not imply that the referenced property will or will not be free from flooding or damage. A property not in the Special Flood Hazard Area or in a City Designated Floodplain may be damaged by a flood greater than that predicted on the map or from a local drainage problem not shown on the map. This map does not create liability on the part of the City, or any officer or employee thereof, for any damage that results from reliance on this information. City Flood Risk Map Moderate Risk May include:- Areas of FEMA 500-year floodplain (FEMA Zone X-shaded).- Areas of FEMA or City 100-year floodplain (sheet flow) withaverage depths of less than 1 foot.- Areas protected by levees from the 100-year flood.Low Risk Areas outside of FEMA and City mapped 100-year and 500-year floodplains. Local drainage problems may still exist. City Flood Fringe - May Include:- Areas of FEMA 100-year floodplain (FEMA Zones A, AE, AO, and AH)- Areas of City 100-year floodplain including ponding areas and sheetflow areas with average depths of 1-3 feet.There is a 1% annual chance that these areas will be flooded. High Risk City Floodway - Area of 100-year floodplain with greatest depths and fastest velocities. 0 40 80 120 16020Feet FIGURE 4 SUBJECT PROPERTY 50 7 5 50 7 6 50 7 4 50 7 3 507 2 5071 50 7 0 50 7 1 50 7 0 507650 7 6 5077 507 7 adjacent house adjacent garageadj shedadjacent building SO U T H T A F T H I L L R O A D XS # . 1 0 7 9 5 0 7 0 . 7 2 f t N A V D 8 8 XS # . 1 0 4 6 5 0 7 0 . 4 4 f t N A V D 8 8 XS # . 1 0 1 1 5 0 6 8 . 7 2 f t N A V D 8 8 XS # . 1 4 7 7 5 0 7 5 . 9 4 f t N A V D 8 8 XS # . 1 1 9 5 5 0 7 1 . 5 9 f t N A V D 8 8 LOT 1 26162.75 Sq. Ft. 0.60 Acres 5068' 5070' 5072' 5074' 5076' 5078' 5072' 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+60 2+80 3+00 3+20 3+40 3+60 3+80 4+00 4+20 4+40 DUCT WORK DUCT WORK PRINCIPAL RESIDENCE ADU - DETATCHED BFE 5070.72 FF 5075.4FF 5076 BFE 5072.9 MIN DUCT 5074.4BFE 5073.5 MIN DUCT 5075 100-YR BASE FLOOD ELEVATIONEXISTING GRADE 5075' 5074' 5073' 5071' PROPOSED 5071.2' PROPOSED 5071.7' SPREAD FOOTING W/ FOUNDATION WALL (TOP OF FOOTER MIN 30" BELOW EXIST GRADE) BFE 5075.94 6" VERTICAL CURB SECTION A - A' SCALE: HORIZONTAL 1" = 20' VERTICAL 1" = 4' (5:1 EXAGGERATION) EL E V A T I O N 1 " = 4 ' OUTLOT (EXIST GRADES/VEGETATION TO REMAIN UNDISTURBED) A' A BFE 5071.59' QU I T C L A I M - R E C . NO . 2 0 0 7 0 0 1 5 2 3 5 GRADE FOR NE FLOW PATTERN PENNSYLVANIA STREET 57' RIGHT OF WAY 30.00' SETBACK 42.00' 15.00' UTILITY EASEMENT PR O P E R T Y B O U N D A R Y Parking Spaces (10'x20') Recycled Asphalt / Road Base NEW ACCESS TO S TAFT HILL ROAD (see detail sheet U105 - Note 3) EXISITNG ACCESS TO BE REMOVED AND REPLACED WITH NEW CURB, GUTTER, AND SIDEWALK TO MATCH EXISTING (see detail drawing 701, Sheet U105) BUILDING ENVELOPE PRINCIPAL RESIDENCE 60' 35 '2100 sf GRAVEL OR RECYCLED ASPHALT ADU - DETACHED 25 ' 40'10' 1000 sf 5077 12.00' 5071.7' X 5071.2' 50 7 0 . 9 ' 5070.4' X X X5070.9' 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5072.5' X 5072.5' X 5071.5' X FF 5075.4' See Cross Section LCUASS Fig 7-11F (sheet U105) Amended for site conditions: 8' Utility Easement on one side onlyCONRETE ALLEY S S PROPOSED GRADE SHALL REMAIN AS EXISTING WITH THE FOLLOWING EXCEPTION: PROPOSED GRADE DIPS SLIGHTLY AT APPROXIMATE STRUCTURE CENTERLINE TO PROMOTE FLOW THROUGH VENT S S PROPOSED 5070.9' PROPOSED 5070.4' ONE (1) SUMP PUMP SHALL BE INSTALLED NEAR THE DOWNSTREAM (EAST) SIDE OF EACH STRUCTURE. SUMP PUMP SHALL BE SUPERIOR PUMP 92372, 1 3 HP THERMOPLASTIC SUBMERSIBLE PUMP WITH VERTICAL FLOAT CONTROL SWITCH OR APPROVED EQUAL. 4' SIDEWALK TOTAL DISTURBED AREA: LOT 1 = 26,163 SF = 0.60 ACRES 0+79 1+ 3 6 2+75 3+15 3+25 EXISTING PROPOSED 4+60 4+80 5+00 0+ 7 9 0+ 0 0 2+ 7 5 3+ 1 5 3+ 8 5 1+ 3 6 0+ 7 9 0+ 0 0 2+ 7 5 3+ 1 5 3+ 8 5 1+ 0 4 PROTECT EXISTING ACCESS FROM NEIGHBORING PROPERTY ONTO S TAFT HILL RD 0 40 20 N o r t h - S c a l e 1 " = 2 0 ' SEAL LEGEND DRAWN BY: PS PAS CHECKED BY: SHEET NUMBER: SCALE: DATE: 08/04/2025 SHEET INDEX: JOB NUMBER: RE V I S I O N S PR O J E C T NO . DA T E DE S C R I P T I O N FO R T C O L L I N S , C O L O R A D O SH E E T T I T L E SO R E N S E N E N G I N E E R I N G & C O N S T R U C T I O N , I N C CI V I L / E N V I R O N M E N T A L E N G I N E E R I N G 19 0 1 B E A R C O U R T FO R T C O L L I N S , C O 8 0 5 2 5 PH O N E : 9 7 0 5 9 0 - 1 5 7 9 pa u l @ s e c e n g i n e e r i n g . n e t 34 1 S O U T H T A F T H I L L R O A D GR A D I N G A N D D R A I N A G E P L A N AS NOTED PROPOSED CONTOUR FIG 5 ELEVATION TABLE UNIT PROPOSED GRADE BFE FF (UPSTREAM SIDE) PRIMARY RES 5070.9 5072.9 5075.4 ADU 5071.7 5073.5 5076 EXISTING GRADE @ UPSTREAM SIDE OF UNIT ESTIMATED ELEVATIONS - INTERPOLATED @UNIT N-S ℄ XS#.1477 AND XS#.1195 - BASE FLOOD ELEVATIONS CROSS-SECTION GILMARTIN MINOR SUBDIVISION NOTES: 1. AT THE TIME PENNSYLVANIA STREET IS FULLY CONSTRUCTED, ACCESS TO THIS PROPERTY MUST BE TAKEN FROM PENNSYLVANIA STREET AND THE ACCESS TAKEN FROM S TAFT HILL ROAD MUST BE CLOSED. 2. THE TOP OF FOUNDATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRE FOR PROTECTION FROM THE 100-YEAR STORM. 3. PROTECT EXISTING ACCESS FROM NEIGHBORING PROPERTY ONTO S TAFT HILL ROAD. 4. NO TRACKING OF DEBRIS OR SEDIMENT IS ALLOWED ON NEIGHBORING PROPERTYOR PUBLIC RIGHT OF WA. IF TRACKING DOES OCCUR, CONTRACTOR SHALL CLEAN IT IMMEDIATELY. PROPOSED RUNOFF FLOW DIRECTION S SUMP PUMP: ONE EACH STRUCTURE EXISTING CONTOUR5073 FLODPLAIN AND FLOODWAY NOTES 1. THE ENTIRE PROPERTY IS CURRENTLY LOCATED IN THE CITY REGULATED 100-YEAR CANAL IMPORTATION FLOOD FRINGE AND MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF MUNICIPAL CODE. 2. ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING,, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS. 3. THE LOWEST FINISHED FLOOR ELEVATION OF A NEW RESIDENTIAL STRUCTURE, AND ALL DUCT WORK, HEATING, VENTILATION, ELECTRICAL SYSTEMS, ETC. MUST BE ELEVATED 18 INCHES. 4. ANY NEW CRAWL SPACE MUST COMPLY WITH VENTING AND CRAWL SPACE REQUIEMENTS FROM SECTIONS 10 39 AND 10 40 OF CITY MUNICIPAL CODE. ROOF DRAIN 50 7 5 50 7 6 50 7 4 50 7 3 507 2 5071 50 7 0 50 7 1 50 7 0 507650 7 6 5077 adjacent house adjacent garageadj shedadjacent building SO U T H T A F T H I L L R O A D XS # . 1 0 7 9 5 0 7 0 . 7 2 f t N A V D 8 8 XS # . 1 0 4 6 5 0 7 0 . 4 4 f t N A V D 8 8 XS # . 1 0 1 1 5 0 6 8 . 7 2 f t N A V D 8 8 XS # . 1 4 7 7 5 0 7 5 . 9 4 f t N A V D 8 8 XS # . 1 1 9 5 5 0 7 1 . 5 9 f t N A V D 8 8 LOT 1 26162.75 Sq. Ft. 0.60 Acres 5068' 5070' 5072' 5074' 5076' 5078' 5072' 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40 2+60 2+80 3+00 3+20 3+40 3+60 3+80 4+00 4+20 4+40 DUCT WORK DUCT WORK PRINCIPAL RESIDENCE ADU - DEDATCHED BFE 5070.72 FF 5075.4FF 5076 BFE 5072.9 MIN DUCT 5074.4BFE 5073.5 MIN DUCT 5075 100-YR BASE FLOOD ELEVATIONEXISTING GRADE 5075' 5074' 5073' 5071' PROPOSED 5071.2' PROPOSED 5071.7' SPREAD FOOTING W/ FOUNDATION WALL (TOP OF FOOTER MIN 30" BELOW EXIST GRADE) BFE 5075.94 6" VERTICAL CURB SECTION A - A' SCALE: HORIZONTAL 1" = 20' VERTICAL 1" = 4' (5:1 EXAGGERATION) EL E V A T I O N 1 " = 4 ' OUTLOT (EXIST GRADES/VEGETATION TO REMAIN UNDISTURBED) A' A SF SF SF SF BFE 5071.59' QU I T C L A I M - R E C . NO . 2 0 0 7 0 0 1 5 2 3 5 GRADE FOR NE FLOW PATTERN PENNSYLVANIA STREET 57' RIGHT OF WAY 30.00' SETBACK 42.00' 15.00' UTILITY EASEMENT PR O P E R T Y B O U N D A R Y Parking Spaces (10'x20') Recycled Asphalt / Road Base NEW ACCESS TO S TAFT HILL ROAD (see detail sheet U105 - Note 3) EXISITNG ACCESS TO BE REMOVED AND REPLACED WITH NEW CURB, GUTTER, AND SIDEWALK TO MATCH EXISTING (see detail drawing 701, Sheet U105) BUILDING ENVELOPE PRINCIPAL RESIDENCE 60' 35 '2100 sf GRAVEL OR RECYCLED ASPHALT ADU - DETACHED 25 ' 40'10' 1000 sf VTC FLOOD VENTS (1 SQ INCH VENT/1 SQ FOOT BUILDING): RECOMMEND FLOOD VENTS BY SMART VENT OR EQUAL - ALL 2X2 MULTI-VENT CONFIGURATION RS CWA CWA CONCRETE WASHOUT AREA - EXACT LOCATION TBD BY CONTRACTOR. CANNOT ENCROACH ON ADJACENT PROPERTY. 5077 12.00' STRUCTURE MODEL # FLOOR COVERAGE PER VENT (SF) AIR VENTILATION (SQ IN) # VENTS EACH END PRINCIPAL RESIDENCE ADU 1540- 150202 800 204 3 1540- 510 200 51 1 1540- 511 400 102 2 FLOOD VENT (3 EACH END, BOTH STRUCTURES) (TYP) 5071.7' X GRADE CRAWL SPACE TO PROMOTE FLOW TO VENTS (BOTH STRUCTURES) 5071.2' 50 7 0 . 9 ' 5070.4' X X X5070.9' 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5072.5' X 5072.5' X 5071.5' X FF 5075.4' See Cross Section LCUASS Fig 7-11F (sheet U105) Amended for site conditions: 8' Utility Easement on one side onlyCONRETE ALLEY S S PROPOSED GRADE SHALL REMAIN AS EXISTING WITH THE FOLLOWING EXCEPTION: PROPOSED GRADE DIPS SLIGHTLY AT APPROXIMATE STRUCTURE CENTERLINE TO PROMOTE FLOW THROUGH VENT S S PROPOSED 5070.9' PROPOSED 5070.4' ONE (1) SUMP PUMP SHALL BE INSTALLED NEAR THE DOWNSTREAM (EAST) SIDE OF EACH STRUCTURE. SUMP PUMP SHALL BE SUPERIOR PUMP 92372, 1 3 HP THERMOPLASTIC SUBMERSIBLE PUMP WITH VERTICAL FLOAT CONTROL SWITCH OR APPROVED EQUAL. VENT BOTTOM ELEVATION EAST: 5070.5' WEST: 5071.0' EAST: 5071.3' WEST: 5071.8' EAST: 5071.3' WEST: 5071.8' 1. THESE ARE DUAL-FUNCTION VENTS, PROVIDING BOTH FLOOD PROTECTION AND NATURAL AIR VENTILATION 4' SIDEWALK TOTAL DISTURBED AREA: LOT 1 = 26,163 SF = 0.60 ACRES 0+79 1+36 2+75 3+15 3+25 EXISTING PROPOSED 4+60 4+80 5+00 SSA SP SF 1+ 3 6 0+ 7 9 0+ 0 0 2+ 7 5 3+ 1 5 3+ 8 5 1+ 3 6 0+ 7 9 0+ 0 0 2+ 7 5 3+ 1 5 3+ 8 5 1+ 0 4 0 40 20 N o r t h - S c a l e 1 " = 2 0 ' SEALLEGEND DRAWN BY: PS PAS CHECKED BY: SHEET NUMBER: SCALE: DATE: 08/04/2025 SHEET INDEX: JOB NUMBER: RE V I S I O N S PR O J E C T NO . DA T E DE S C R I P T I O N FO R T C O L L I N S , C O L O R A D O SH E E T T I T L E SO R E N S E N E N G I N E E R I N G & C O N S T R U C T I O N , I N C CI V I L / E N V I R O N M E N T A L E N G I N E E R I N G 19 0 1 B E A R C O U R T FO R T C O L L I N S , C O 8 0 5 2 5 PH O N E : 9 7 0 5 9 0 - 1 5 7 9 pa u l @ s e c e n g i n e e r i n g . n e t 34 1 S O U T H T A F T H I L L R O A D ER O S I O N C O N T R O L A N D F L O O D P R O O F I N G P L A N AS NOTED PROPOSED CONTOUR SILT FENCESF FIG 6 GILMARTIN MINOR SUBDIVISION VTC VEHICLE TRACKING CONTROL NOTES: 1. AT THE TIME PENNSYLVANIA STREET IS FULLY CONSTRUCTED, ACCESS TO THIS PROPERTY MUST BE TAKEN FROM PENNSYLVANIA STREET AND THE ACCESS TAKEN FROM S TAFT HILL ROAD MUST BE CLOSED. 2. THE TOP OF FOUNDATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRE FOR PROTECTION FROM THE 100-YEAR STORM. 3. PROTECT EXISTING ACCESS FROM NEIGHBORING PROPERTY ONTO S TAFT HILL ROAD. 4. NO TRACKING OF DEBRIS OR SEDIMENT IS ALLOWED ON NEIGHBORING PROPERTYOR PUBLIC RIGHT OF WA. IF TRACKING DOES OCCUR, CONTRACTOR SHALL CLEAN IT IMMEDIATELY. RS ROCK SOCK PROPOSED RUNOFF FLOW DIRECTION CWA CONCRETE WASHOUT AREA S SUMP PUMP: ONE EACH STRUCTURE EXISTING CONTOUR5073 SSA SP SF SEDIMENT STRAINING STOCKPILE MANAGEMENT STABILIZED STAGING AREA FLODPLAIN AND FLOODWAY NOTES 1. THE ENTIRE PROPERTY IS CURRENTLY LOCATED IN THE CITY REGULATED 100-YEAR CANAL IMPORTATION FLOOD FRINGE AND MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF MUNICIPAL CODE. 2. ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING,, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS. 3. THE LOWEST FINISHED FLOOR ELEVATION OF A NEW RESIDENTIAL STRUCTURE, AND ALL DUCT WORK, HEATING, VENTILATION, ELECTRICAL SYSTEMS, ETC. MUST BE ELEVATED 18 INCHES. 4. ANY NEW CRAWL SPACE MUST COMPLY WITH VENTING AND CRAWL SPACE REQUIEMENTS FROM SECTIONS 10 39 AND 10 40 OF CITY MUNICIPAL CODE. 12 Appendix A NCRS Custom Soil Resources Report 13 Appendix B Hydrologic Calculations Runoff Coefficient Calculations Mile High Flood District Peak Runoff Prediction by the Rational Method, Version 2.00 GILMARTIN SUBDIVISION HISTORICAL AND PROPOSED RUNOFF COEFFICIENT CALCULATIONS Total Drainage Area - 0.71 Acres = Surface Cover/Use Defined %i1 Historical Proposed 2 Historical %i Proposed %i Area (sf) Purpose:This workbook applies the Rational Method to estimate stormwater runoff and peak flows from small urban catchments (typically less than 90 acres) Function:1. To calculate the runoff coefficient, C for a catchment 2. To calculate the time of concentration, and then compare with the regional time of concentration limit used for the Denver region. The smaller one is recommended as the rainfall duration for use with the Rational Method. 3. To calculate the design rainfall intensity and resulting peak flow rate. Content:The workbook consists of the following five sheets: Intro Describes the purpose of each sheet in the workbook. Rational Calcs Performs Rational Method calculations, Q = CIA Weighted C Supporting tool to calculate area-weighted runoff coefficients from sub-areas. Weighted Slope Supporting tool to calculate length-weighted slope from multiple flow reaches. Weighted Tc Supporting tool to calculate reach-weighted time of concentration from multiple flow reaches. Design Info Provides background information from the USDCM Acknowledgements:Spreadsheet Development Team: Derek N. Rapp, P.E. Peak Stormwater Engineering, LLC Holly Piza, P.E. and Ken MacKenzie, P.E. Urban Drainage and Flood Control District Comments?Direct all comments regarding this spreadsheet workbook to:UDFCD email Revisions?Check for revised versions of this or any other workbook at:Downloads PEAK RUNOFF PREDICTION BY THE RATIONAL METHOD Denver, Colorado Urban Drainage and Flood Control District Version 2.00 released May 2017 , Intro , Designer: Company:2-yr 5-yr 10-yr 25-yr 50-yr 100-yr 500-yr Date:1-hour rainfall depth, P1 (in) =0.82 1.20 1.40 2.00 2.40 2.86 3.00 Project:a b c Location:Rainfall Intensity Equation Coefficients =28.50 10.00 0.786 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr 500-yr Overland Flow Length Li (ft) U/S Elevation (ft) (Optional) D/S Elevation (ft) (Optional) Overland Flow Slope Si (ft/ft) Overland Flow Time ti (min) Channelized Flow Length Lt (ft) U/S Elevation (ft) (Optional) D/S Elevation (ft) (Optional) Channelized Flow Slope St (ft/ft) NRCS Conveyance Factor K Channelized Flow Velocity Vt (ft/sec) Channelized Flow Time tt (min) Computed tc (min) Regional tc (min) Selected tc (min)2-yr 5-yr 10-yr 25-yr 50-yr 100-yr 500-yr 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr 500-yr 0.01 0.05 0.15 0.33 0.40 0.49 0.59 28.69 32.29 29.55 1.30 1.90 2.22 3.17 3.80 4.53 4.75 0.01 0.07 0.23 0.74 1.09 1.58 2.00 0.20 0.20 0.20 0.22 0.24 0.25 0.30 24.62 28.23 28.23 1.33 1.95 2.28 3.25 3.90 4.65 4.88 0.19 0.28 0.32 0.51 0.66 0.83 1.04 0.21 0.28 0.35 0.49 0.54 0.61 0.68 15.90 18.73 18.73 1.67 2.44 2.85 4.07 4.88 5.82 6.11 0.25 0.48 0.71 1.40 1.87 2.50 2.96 0.36 0.36 0.36 0.39 0.43 0.45 0.50 14.35 17.18 17.18 1.74 2.55 2.98 4.25 5.10 6.08 6.38 0.44 0.65 0.76 1.19 1.56 1.93 2.26 0.015300.00 Rainfall Intensity, I (in/hr) 1.22 3.61 29.55100.015265.00 Peak Flow, Q (cfs) Calculation of Peak Runoff using Rational Method Overland (Initial) Flow Time Channelized (Travel) Flow Time Time of ConcentrationRunoff Coefficient, C Subcatchment Name Area (ac) NRCS Hydrologic Soil Group Percent Imperviousnes s EXISTING 0.71 C 2.0 Select UDFCD location for NOAA Atlas 14 Rainfall Depths from the pulldown list OR enter your own depths obtained from the NOAA website (click this link) Cells of this color are for required user-input Cells of this color are for optional override values Cells of this color are for calculated results based on overrides Paul Sorensen Sorensen Engineering & Construction, Inc. 7/28/25 Taft Hill Subdivision: EXISTING & PROPOSED 341 South Taft Hill Road, Fort Collins, CO Version 2.00 released May 2017 PROPOSED 0.71 C 29.8 150.00 0.015 415.00 0.015 20 2.45 2.82 25.22 I 𝑖𝑛/ℎ𝑟=a ∗P1 b +tc c ti =0.395 1.1 −C5 Li Si0.33 tt =Lt 60K St =Lt 60Vt Computed tc =ti +tt Regional tc =26 −17i +Lt 60 14i +9 St Selected tc =max tminimum ,min Computed tc ,Regional tc tminimum=5 (urban) tminimum=10 (non-urban) Q 𝑐𝑓𝑠=CIA Supplementary Design Information for UD-Rational Workbook Urban Storm Drainage Criteria Manual (USDCM) Volume 1, Chapter 6 - Runoff (March 2017) Version 2.00 released May 2017 Page 6 Supplementary Design Information for UD-Rational Workbook Urban Storm Drainage Criteria Manual (USDCM) Volume 1, Chapter 6 - Runoff (March 2017) Version 2.00 released May 2017 Page 7