HomeMy WebLinkAboutReports - 06/01/2025
COLLEGE & TRILBY
WASTEWATER IMPACT ANALYSIS REPORT
June 2025
Prepared For:
Zocalo
455 Sherman Street, Ste 250
Denver, CO 80020
(303) 820-8611
Contact: Kolby O Herron
Prepared By:
JR ENGINEERING, LLC
2900 S College Avenue, Ste 1A
Fort Collins, CO 80525
303-267-6235
Contact: Andrew Hugill, PE
(Project No. 39793.03)
College & Trilby WIAR May 2025
i
Table of Contents
CERTIFICATION STATEMENT .................................................................................................................... ii
I. INTRODUCTION ............................................................................................................................... 1
Project Location and Description ......................................................................................................... 1
II. SANITARY SEWER SYSTEM ............................................................................................................... 2
Existing and Proposed System ............................................................................................................. 2
Calculated Wastewater Flows and Design Flow Requirements ............................................................. 2
Hydraulic Analysis ................................................................................................................................ 3
Conclusions ......................................................................................................................................... 3
III. REFERENCES ................................................................................................................................ 4
Appendices
A: Vicinity Map
B: SFCSD Design Sheet, Sanitary Sewer Loading, Sanitary Map, StormCAD Results
College & Trilby WIAR May 2025
ii
CERTIFICATION STATEMENT
This Wastewater Impact Analysis Report for the design of the College & Trilby development was
prepared by me or under my direct supervision in accordance with the South Fort Collins Sanitation
District Standards and Specifications and acceptable professional practices of the industry.
_______________________________________________________
Andrew J. Hugill, Registered Professional Engineer
Colorado Professional Engineer No. 57007
For and on behalf of JR Engineering, LLC
College & Trilby WIAR May 2025
1
I. INTRODUCTION
Project Location and Description
The site is located in The Southeast Quarter of Section 11, Township 6 North, Range 69 West of
the 6th P.M. in the City of Fort Collins, Larimer County, Colorado. More specifically, the site is
a 39.18 acre property that is currently undeveloped. The site borders College Ave to the East,
Trilby Road, South Gate Church, and a right in and right out with access to Ziggy's Coffee to the
south. To the west, the site borders a detention pond that controls runoff for the First Free Will
Baptist Church, the Skyview South First Filing Subdivision, and a social services organization
owned by Foothills Gateway Inc. To the north, the site borders Hazel Self Storage, two current
vacant parcels of land, and a portion of Skyview Drive.
The College and Trilby site is composed of 264 single family equivalent unit lots all designated
as single family attached. The site also has a recreation center with a pool. Sanitary loadings on
the site travel from the south end of the site to the north end of the site via an existing eight -inch
sanitary sewer system.
College & Trilby WIAR May 2025
2
II. SANITARY SEWER SYSTEM
Existing and Proposed System
The College and Trilby sanitary sewer will connect into an existing 8” South Fort Collins
Sanitation sewer line located at the northeastern corner of the property with a new proposed
manhole.
There is an existing eight-inch sanitary sewer system traversing the project site that will be
removed upon installation of the proposed sanitary sewer system servicing the site. Currently,
the existing system receives loading from a portion of residential development south of Trilby,
two church buildings and the Ziggy’s coffee shop. These loadings will be bypassed during the
construction of the proposed system. A map of the existing and proposed sanitary sewer system
is included in Appendix B.
Calculated Wastewater Flows and Design Flow Requirements
The basis of design for this study was set forth in the South Fort Collins Sanitation District
Development and Design Specifications, version 9/29/2023. The following is a summary of the
criteria used to establish the wastewater flows and final sanitary sewer design:
Criteria for Establishing Wastewater Flows
Single-Family Residential Population Density: 3.20 Capita/dwelling unit
Residential Average Use: 80 gpd/capita
Peak Factor: 3.0
Infiltration and Inflow Rate (for all uses): 5% of total peak loading
Mannings value: 0.013
Design Requirements
Diameter Minimum Slope Maximum Slope Minimum Flow Velocity
(at peak design flow, and n=0.013)
8 in (minimum) 0.40% 8.3% 2 ft/s
The proposed College and Trilby development has a total area of approximately 39.18 acres,
comprised of 264 single-family detached residential lots. This corresponds to an estimated total
population of 845 and an estimated population density of 21.6 people per acre. The recreation
center and pool is assumed to serve approximately 50 people on average at 15 gallons per person
per day. The total wastewater design flows calculated for College and Trilby are shown in Table
1 below.
College & Trilby WIAR May 2025
3
Table 1: College and Trilby Total Wastewater Design Flows Summary Table
Acres DU’s
Recreation Center
(capita)
Flow Rate (gpd)
Average
Day Peak Day
Peak Day Flow +
Infiltration and
Inflow
39.18 264 50 68,334 205,002 215,252
Wastewater from the College and Trilby site will be ordinary domestic sewage from single-
family residences, and will not contain industrial waste.
Flow monitoring data was provided by SFCSD at MH 3550 (EXMH-02) and MH2308 (EXMH-
08) from March 12 to April 16 to utilize in the on-site and off-site analysis. The peak flows in
MH 3550 and MH2308 were approximately 46gpm and 166gpm respectively. The provided flow
monitoring peak flows were rounded up to 50gpm(0.1114cfs) and 170gpm(0.3788cfs) and
incorporated into the existing and proposed analysis.
Hydraulic Analysis
The proposed site was analyzed in both an existing condition and a proposed condition.
StormCAD was utilized in order to confluence sanitary flows and account for flow timing within
the proposed system and results can be found in Appendix B. The proposed condition
incorporated the peak flow from the flow monitoring of MH3550 and routed the peak flow
through the site. SFCSD also requested that a portion of their existing system is analyzed
approximately ten manholes downstream.
The existing analysis of the offsite system SFCSD was interested in was also analyzed to
establish a baseline for the system.
Note that in the proposed condition analysis the flow velocities range sometimes fall below the
minimum flow velocity criteria of 2 ft/s. The low velocities are typical considering the low
number of lots contributing to the sewer system in those sections. The proposed 8” sanitary
sewer pipes are the minimum size allowed, and steeper slopes are not feasible given depth
constraints set by the existing sanitary sewer line downstream.
Conclusions
This study presents the results of the analysis performed for the sanitary sewer system associated
with the proposed College and Trilby Development. The design and layout of the sanitary sewer
system as shown and discussed in this study and Appendices conform to the SFCSD design
standards.
College & Trilby WIAR May 2025
4
III. REFERENCES
1. South Fort Collins Sanitation District, Development and Design Specifications; 2023
College & Trilby WIAR May 2025
Appendix A
Vicinity Map
A Westrian Company
College & Trilby WIAR May 2025
Appendix B
Sanitary Sewer System Loading, Sanitary Map,
and StormCAD Results
Design Criteria Fact Sheet
South Fort Collins Sanitation District
This Fact Sheet is provided as a courtesy. It is the Design Engineer’s responsibility to be aware of all requirements of
the South Fort Collins Sanitation District Development and Design Specifications.
(Version 9/29/2023)
Calculations: use Manning’s Equation with 0.013 coefficient
Velocity: minimum 2 ft/sec, maximum 7 ft/sec
Depth Ratio Maximum (d/D ): ≤15 inch diameter: 0.5, >15 inch diameter: 0.75
Pipe Size: minimum 8 inch diameter for mains, 4 inch diameter for services
Peaking Factor: 3
Separation Minimums: 10 feet from water supply and trees, 1.5 feet vertically from all utilities.
Potable water lines shall pass above sewer lines unless specifically exempted.
Manhole Drop Min.: straight channel to 45° bend: 0.1 ft, 45° - 75°: 0.2 ft, 75° - 90°: 0.3 ft
Average Daily Flow:
Pipe Slope:
Land Use Criteria
All Residential 80 gpd/capita
Single Family Residential
Single Family Attached 3.2 capita/dwelling unit
Multi-Family (≥3 units) 2.8 capita/dwelling unit
Retail, Offices 0.2 gpd/sq ft
Hotels
(meeting space, add 0.6 gpd/sq ft) 75 gpd/guest room
Commercial, Industrial, Institutional,
Churches and Others Considered case-by-case
Pipe Diameter
(inches)
Minimum Slope
(Percent)
Maximum Slope
(Percent)
Service
Laterals
4 2.0 21
6 1.0 12
Sewer
Mains
8 0.40 8.3
10 0.28 6.2
12 0.22 4.9
15 0.15 3.6
18 0.12 2.8
21 0.10 2.3
24 0.08 1.9
MH ID Number of SF Units Cumulative Units ADF (gpm) ADF (cfs) I&I (gpm) Peak Flow (gpm) Peak Flow (cfs)Notes
MH-32 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-33 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-15 0 0 0.00 0.0000 0.0000 50.0 0.1114 Flow Monitoring Data MH3550
MH-14 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-13 13 13 2.31 0.0051 0.1156 7.3 0.0162
MH-29 0 0 0.00 0.0000 0.0000 0.0 0.0000 Existing church and Ziggy's loading incorporated into MH-05 loading
MH-11 3 57 0.53 0.0012 0.0267 1.7 0.0037
MH-10 6 63 1.59 0.0035 0.0794 5.0 0.0111 Rec center & Pool total 50 Customers
MH-28 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-26 0 24 0.00 0.0000 0.0000 0.0 0.0000
MH-08 30 120 5.33 0.0119 0.2667 16.8 0.0374
MH-07 6 126 1.07 0.0024 0.0533 3.4 0.0075
MH-25 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-24 21 21 3.73 0.0083 0.1867 11.8 0.0262
MH-23 25 46 4.44 0.0099 0.2222 14.0 0.0312
MH-05 4 206 0.71 0.0016 0.0356 2.2 0.0050
MH-21 0 0 0.00 0.0000 0.0000 0.0 0.0000
MH-20 12 12 2.13 0.0048 0.1067 6.7 0.0150
MH-19 21 33 3.73 0.0083 0.1867 11.8 0.0262
MH-18 6 39 1.07 0.0024 0.0533 3.4 0.0075
MH-17 0 39 0.00 0.0000 0.0000 0.0 0.0000
MH-03 3 264 0.53 0.0012 0.0267 1.7 0.0037
MH-02 0 264 0.00 0.0000 0.0000 0.0 0.0000
Total 0.4444
College & Trilby Sanitary Sewer Loading
Proposed Condition Peak Flow
Depth/Rise
(%)
Depth
(Out)
(ft)
Depth
(In)
(ft)
Flow
(gpm)
Velocity
(ft/s)
Manning's
n
Slope
(ft/ft)
Length
(User
Defined)
(ft)
Invert
(Stop)
(ft)
Invert
(Start)
(ft)
Label
56.50.370.38215.712.350.0130.004115.55,006.495,006.97EXSP-01
52.40.320.37215.712.380.0130.004286.55,005.265,006.49EXSP-02
53.20.320.39215.712.300.0130.004360.15,003.445,004.86EXSP-03
53.60.320.39215.712.270.0130.004229.65,002.475,003.34EXSP-04
53.20.320.38215.712.300.0130.004176.85,001.675,002.37EXSP-05
50.90.320.35215.712.540.0130.005415.44,999.445,001.57EXSP-06
139.71.450.41335.736.840.0130.055140.54,990.094,997.81EXSP-07
180.50.901.50335.732.140.0130.000169.74,989.994,990.04EXSP-08
98.40.410.90335.732.140.0130.003400.44,988.864,989.99EXSP-09
65.50.470.41335.733.710.0130.010365.44,984.824,988.64EXSP-10
65.50.410.47335.732.830.0130.0054,984.724,984.82Outfall
50.00.320.34215.712.660.0130.005412.95,007.275,009.48SP-01
49.80.320.34215.712.690.0130.00621.55,009.685,009.80SP-02
46.90.290.34174.192.200.0130.004131.75,009.905,010.43SP-03
45.80.280.33166.922.180.0130.004149.35,010.535,011.13SP-04
39.00.240.28123.792.010.0130.004118.75,011.235,011.70SP-05
38.80.240.28122.132.000.0130.004118.75,011.805,012.27SP-06
38.10.240.27118.761.990.0130.004212.95,012.375,013.22SP-07
64.90.660.2088.552.910.0130.014387.85,012.835,018.43SP-08
32.30.200.2386.891.820.0130.004121.25,018.535,019.01SP-09
31.30.200.2281.911.800.0130.004205.85,019.115,019.93SP-10
23.60.120.1980.254.180.0130.044124.75,020.235,025.68SP-11
22.00.130.1657.272.660.0130.016291.55,025.985,030.70SP-12
24.30.150.1750.001.560.0130.004183.25,030.805,031.53SP-13
24.30.150.1750.001.560.0130.00456.85,031.835,032.06SP-14
18.00.100.1439.862.530.0130.019129.15,026.555,028.99SP-15
18.90.120.1338.202.000.0130.01059.25,029.295,029.88SP-16
18.90.120.1338.202.000.0130.010146.75,030.185,031.65SP-17
17.50.110.1334.832.140.0130.01329.25,031.855,032.23SP-18
7.80.050.056.731.290.0130.013353.95,032.535,037.14SP-19
0.00.000.000.000.000.0130.007353.55,037.345,039.70SP-20
17.30.090.1440.893.100.0130.033250.55,021.845,030.18SP-21
17.40.110.1225.761.290.0130.004290.35,030.385,031.54SP-22
11.80.070.0811.761.020.0130.004336.65,031.645,032.99SP-23
0.00.000.000.000.000.0130.005210.25,033.095,034.08SP-24
41.30.460.0913.421.060.0130.004171.85,013.035,013.72SP-25
12.60.080.0913.421.060.0130.00430.05,013.925,014.04SP-26
0.00.000.000.000.000.0130.023288.65,014.245,020.93SP-27
0.00.000.000.000.000.0130.00459.95,020.235,020.47SP-28
10.30.060.0814.002.110.0130.028124.75,025.985,029.41SP-29
7.00.040.055.611.330.0130.01776.65,030.715,031.99SP-30
0.00.000.000.000.000.0130.021380.25,032.195,040.34SP-31
0.00.000.000.000.000.0130.013352.25,030.715,035.29SP-32
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT
06795 USA +1-203-755-1666
6/24/2025
StormCAD
[10.03.02.04]Bentley Systems, Inc. Haestad Methods Solution Center3979303Sanitary.stsw
Proposed Condition Peak Flow
Hydraulic
Grade Line
(Out)
(ft)
Hydraulic
Grade Line
(In)
(ft)
Flow
(Total
Out)
(gpm)
Velocity
(Out)
(ft/s)
Elevation
(Invert)
(ft)
Elevation
(Ground)
(ft)
Label
5,006.865,006.86215.712.385,006.495,010.06EXMH-01
5,005.255,005.25215.712.305,004.865,010.01EXMH-02
5,003.735,003.73215.712.275,003.345,008.37EXMH-03
5,002.755,002.75215.712.305,002.375,007.25EXMH-04
5,001.925,001.92215.712.545,001.575,006.34EXMH-05
4,998.224,998.22335.733.334,997.815,004.48EXMH-06
4,991.544,991.54335.732.144,990.045,006.28EXMH-07
4,990.894,990.89335.732.144,989.995,002.84EXMH-08
4,989.054,989.05335.733.334,988.645,001.04EXMH-09
4,985.294,985.29335.732.884,984.824,999.38EXMH-10
5,007.355,007.35215.712.355,006.975,012.54MH-01
5,009.825,009.82215.712.665,008.925,031.49MH-02
5,010.145,010.14215.712.695,009.315,032.45MH-03
5,010.775,010.77174.192.205,009.945,031.19MH-04
5,011.465,011.46166.922.185,010.645,030.27MH-05
5,011.985,011.98123.792.005,011.215,026.94MH-06
5,012.555,012.55122.132.005,011.785,023.62MH-07
5,013.495,013.49118.761.995,012.735,021.23MH-08
5,018.635,018.6388.552.185,018.435,030.97MH-09
5,019.245,019.2486.891.825,019.015,032.33MH-10
5,020.155,020.1581.911.805,019.935,035.42MH-11
5,025.875,025.8780.252.125,025.685,038.22MH-12
5,030.865,030.8657.271.935,030.705,043.50MH-13
5,031.705,031.7050.001.565,031.535,046.05MH-14
5,032.235,032.2350.001.565,032.065,047.15MH-15
5,029.135,029.1339.861.745,028.995,039.37MH-16
5,030.015,030.0138.201.735,029.885,038.68MH-17
5,031.785,031.7838.201.735,031.655,040.71MH-18
5,032.365,032.3634.831.695,032.235,041.49MH-19
5,037.195,037.196.731.105,037.145,046.46MH-20
5,039.705,039.700.000.005,039.705,048.58MH-21
5,030.325,030.3240.891.765,030.185,035.18MH-22
5,031.675,031.6725.761.295,031.545,036.93MH-23
5,033.075,033.0711.761.025,032.995,038.95MH-24
5,034.085,034.080.000.005,034.085,040.21MH-25
5,013.815,013.8113.421.065,013.725,019.82MH-26
5,014.135,014.1313.421.065,014.045,020.16MH-27
5,020.935,020.930.000.005,020.935,027.52MH-28
5,020.475,020.470.000.005,020.475,033.56MH-29
5,029.495,029.4914.001.325,029.415,040.63MH-30
5,032.045,032.045.611.045,031.995,042.33MH-31
5,040.345,040.340.000.005,040.345,049.35MH-32
5,035.295,035.290.000.005,035.295,044.63MH-33
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT
06795 USA +1-203-755-1666
6/24/2025
StormCAD
[10.03.02.04]Bentley Systems, Inc. Haestad Methods Solution Center3979303Sanitary.stsw
Existing Condition Peak Flow
Depth/Rise
(%)
Depth
(Out)
(ft)
Depth
(In)
(ft)
Flow
(gpm)
Velocity
(ft/s)
Manning's
n
Slope
(ft/ft)
Length
(User
Defined)
(ft)
Invert
(Stop)
(ft)
Invert
(Start)
(ft)
Label
25.40.170.1750.001.580.0130.004115.55,006.495,006.97EXSP-01
24.10.150.1750.001.600.0130.004286.55,005.265,006.49EXSP-02
24.40.150.1750.001.550.0130.004360.15,003.445,004.86EXSP-03
24.50.150.1750.001.530.0130.004229.65,002.475,003.34EXSP-04
24.40.150.1750.001.560.0130.004176.85,001.675,002.37EXSP-05
23.50.150.1650.001.700.0130.005415.44,999.445,001.57EXSP-06
97.10.920.38286.086.560.0130.055140.54,990.094,997.81EXSP-07
113.30.540.97286.081.830.0130.000169.74,989.994,990.04EXSP-08
68.90.380.54286.082.100.0130.003400.44,988.864,989.99EXSP-09
59.60.420.38286.083.570.0130.010365.44,984.824,988.64EXSP-10
59.60.380.42286.082.750.0130.0054,984.724,984.82Outfall
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.005412.95,007.275,009.48SP-01
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.00621.55,009.685,009.80SP-02
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004131.75,009.905,010.43SP-03
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004149.35,010.535,011.13SP-04
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004118.75,011.235,011.70SP-05
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004118.75,011.805,012.27SP-06
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004212.95,012.375,013.22SP-07
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.014387.85,012.835,018.43SP-08
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004121.25,018.535,019.01SP-09
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004205.85,019.115,019.93SP-10
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.044124.75,020.235,025.68SP-11
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.016291.55,025.985,030.70SP-12
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004183.25,030.805,031.53SP-13
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.00456.85,031.835,032.06SP-14
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.019129.15,026.555,028.99SP-15
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.01059.25,029.295,029.88SP-16
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.010146.75,030.185,031.65SP-17
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.01329.25,031.855,032.23SP-18
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.013353.95,032.535,037.14SP-19
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.007353.55,037.345,039.70SP-20
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.033250.55,021.845,030.18SP-21
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004290.35,030.385,031.54SP-22
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004336.65,031.645,032.99SP-23
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.005210.25,033.095,034.08SP-24
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.004171.85,013.035,013.72SP-25
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.00430.05,013.925,014.04SP-26
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.023288.65,014.245,020.93SP-27
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.00459.95,020.235,020.47SP-28
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.028124.75,025.985,029.41SP-29
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.01776.65,030.715,031.99SP-30
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.021380.25,032.195,040.34SP-31
(N/A)(N/A)(N/A)(N/A)(N/A)0.0130.013352.25,030.715,035.29SP-32
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT
06795 USA +1-203-755-1666
6/24/2025
StormCAD
[10.03.02.04]Bentley Systems, Inc. Haestad Methods Solution Center3979303Sanitary.stsw
Existing Condition Peak Flow
Hydraulic
Grade Line
(Out)
(ft)
Hydraulic
Grade Line
(In)
(ft)
Flow
(Total
Out)
(gpm)
Velocity
(Out)
(ft/s)
Elevation
(Invert)
(ft)
Elevation
(Ground)
(ft)
Label
5,006.665,006.6650.001.605,006.495,010.06EXMH-01
5,005.035,005.0350.001.555,004.865,010.01EXMH-02
5,003.515,003.5150.001.535,003.345,008.37EXMH-03
5,002.545,002.5450.001.565,002.375,007.25EXMH-04
5,001.735,001.7350.001.705,001.575,006.34EXMH-05
4,998.194,998.19286.083.144,997.815,004.48EXMH-06
4,991.014,991.01286.081.834,990.045,006.28EXMH-07
4,990.534,990.53286.082.104,989.995,002.84EXMH-08
4,989.024,989.02286.083.144,988.645,001.04EXMH-09
4,985.244,985.24286.082.764,984.824,999.38EXMH-10
5,007.145,007.1450.001.585,006.975,012.54MH-01
(N/A)(N/A)0.00(N/A)5,008.925,031.49MH-02
(N/A)(N/A)0.00(N/A)5,009.315,032.45MH-03
(N/A)(N/A)0.00(N/A)5,009.945,031.19MH-04
(N/A)(N/A)0.00(N/A)5,010.645,030.27MH-05
(N/A)(N/A)0.00(N/A)5,011.215,026.94MH-06
(N/A)(N/A)0.00(N/A)5,011.785,023.62MH-07
(N/A)(N/A)0.00(N/A)5,012.735,021.23MH-08
(N/A)(N/A)0.00(N/A)5,018.435,030.97MH-09
(N/A)(N/A)0.00(N/A)5,019.015,032.33MH-10
(N/A)(N/A)0.00(N/A)5,019.935,035.42MH-11
(N/A)(N/A)0.00(N/A)5,025.685,038.22MH-12
(N/A)(N/A)0.00(N/A)5,030.705,043.50MH-13
(N/A)(N/A)0.00(N/A)5,031.535,046.05MH-14
(N/A)(N/A)0.00(N/A)5,032.065,047.15MH-15
(N/A)(N/A)0.00(N/A)5,028.995,039.37MH-16
(N/A)(N/A)0.00(N/A)5,029.885,038.68MH-17
(N/A)(N/A)0.00(N/A)5,031.655,040.71MH-18
(N/A)(N/A)(N/A)(N/A)5,032.235,041.49MH-19
(N/A)(N/A)0.00(N/A)5,037.145,046.46MH-20
(N/A)(N/A)0.00(N/A)5,039.705,048.58MH-21
(N/A)(N/A)0.00(N/A)5,030.185,035.18MH-22
(N/A)(N/A)0.00(N/A)5,031.545,036.93MH-23
(N/A)(N/A)0.00(N/A)5,032.995,038.95MH-24
(N/A)(N/A)0.00(N/A)5,034.085,040.21MH-25
(N/A)(N/A)0.00(N/A)5,013.725,019.82MH-26
(N/A)(N/A)0.00(N/A)5,014.045,020.16MH-27
(N/A)(N/A)0.00(N/A)5,020.935,027.52MH-28
(N/A)(N/A)0.00(N/A)5,020.475,033.56MH-29
(N/A)(N/A)0.00(N/A)5,029.415,040.63MH-30
(N/A)(N/A)0.00(N/A)5,031.995,042.33MH-31
(N/A)(N/A)0.00(N/A)5,040.345,049.35MH-32
(N/A)(N/A)0.00(N/A)5,035.295,044.63MH-33
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT
06795 USA +1-203-755-1666
6/24/2025
StormCAD
[10.03.02.04]Bentley Systems, Inc. Haestad Methods Solution Center3979303Sanitary.stsw
A Westrian Company
COLLEGE & TRILBY
OFFSITE SANITARY BASINS
A Westrian Company
ROVER DRIVE
MARS DR
I
V
E
NOVA LANE
GALACTIC LANE
MOONBEAM WAY
LU
N
A
R
C
O
U
R
T
NOVA LA
N
E
STARDU
S
T
L
A
N
E
ST
E
L
L
A
R
D
R
I
V
E
MARS DRIVE
SP-26
DETENTION POND
SP-18
SP-02
MH-32
MH-31
MH-30
MH-12
MH-29
MH-27
MH-26
MH-17
MH-16
MH-02
MH-01
EXMH-01
EXMH-02 EXMH-03
EXMH-04 EXMH-05 EXMH-06
EXMH-07EXMH-08EXMH-09
EXMH-10
SP-31
SP-30SP-32
SP-29
SP-14
SP-13
SP-12
SP-11
SP-28 SP-10
SP-09 SP-08
SP-27
SP-25
SP-07 SP-06
SP-05
SP-24 SP-23
SP-22
SP-21
SP-04
SP-03
SP-20
SP-19
SP-17
SP-16
SP-15
SP-01
EXSP-01
EXSP-02
EXSP-03
EXSP-04
EXSP-05 EXSP-06
EXSP-07
EXSP-08EXSP-09
EXSP-10
MH-03MH-04
MH-05
MH-33
MH-15
MH-14
MH-11
MH-10
MH-09
MH-28
MH-08 MH-07
MH-06
MH-22MH-21 MH-20
MH-19
MH-18
MH-13
MH-23
MH-25 MH-24