Loading...
HomeMy WebLinkAboutPlans - 06/11/2025STEEL MAN DOOR 12' - 0" 16 ' - 0 " STEEL DOORS W. METAL SLAT INFILL & J BOLT OP E N I N G 10 ' - 0 " EN C L O S U R E H E I G H T 6' - 8 " 6' - 8 " PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO 6/ 1 1 / 2 0 2 5 7 : 4 8 : 4 4 A M 1/4" = 1'-0" PR O S P E C T R I D G E 90 0 H I G H W A Y 1 3 3 CA R B O N D A L E C O , 8 1 6 2 3 20-22 Author Checker 2/2/2023 PERMIT TRASH ENCLOSURE & DETAILS Approver 1/4" = 1'-0"1 CMU TRASH ENCLOSURE PLAN 1/4" = 1'-0" SIDE ELEVATION TRASH ENCLOSURE - PERSPECTIVE 1/4" = 1'-0"2 TRASH ENCLOSURE - FRONT ELEVATION 1/4" = 1'-0"3 TRASH ENCLOSURE - REAR ELEVATION () () FLASHING PROFILE INTERIOR EXTERIOR (1) LAYER 1/2" GYP BD EXTERIOR SHEATHING; RE: STRUCT. WEATHER RESISTIVE BARRIER STARTER STRIP; GAPS AT 16" O.C. FOR DRAINAGE; INSTALL 1/2" UP FROM BOTTOM OF SIDING, TYP. NO SEALANT AT THIS LOCATION SELF-ADHERED FLASHING OVERLAPPING WINDOW FLANGE; INSTALLED PER MANUFACTURER'S SPECIFICATIONS VINYL WINDOW WITH LOW-E GLASS SHIM AS REQUIRED 5/4 x 4 FIBER CEMENT TRIM GALVANIZED METAL FLASHING WITH HEMMED EDGE; OVERLAP SEAMS 4" AND FULLY SEAL SEAMS CONTINUOUS BEAD OF SEALANT BETWEEN SHEATHING AND NAILING FIN NO SEALANT AT THIS LOCATION ADHESIVE TAPE BY W.R.B. MFR.; LAP METAL FLASHING 1 1/4" 4" 2X HEADER RE: STRUCTURAL SELF-ADHERED FLASHING; INSTALL PER MFR SPECS. MFR'S SPECS GALVANIZED METAL FLASHING WITH HEMMED EDGE; OVERLAP SEAMS 4" AND FULLY SEAL SEAMS CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"6 WINDOW HEAD AT SIDING & STUCCO () ( ) (1) LAYER 1/2" GYP. BD. 2X6 WOOD FRAMING, RE:STRUCTURAL 5/4 x 4 FIBER CEMENT TRIM CONTINUOUS SEALANT SPEC'S; RE: ELEVATIONS FOR EXPOSURE EXTERIOR SHEATHING; RE: STRUCT. SHIM AS REQUIRED VINYL WINDOW WITH LOW-E GLASS INTERIOR EXTERIOR CONTINUOUS BEAD OF SEALANT BETWEEN SHEATHING AND NAILING FIN CONTINUOUS BACKER ROD AND SEALANT, 1/4" JOINT WEATHER RESISTIVE BARRIER SELF-ADHERED FLASHING OVERLAPPING WINDOW FLANGE; INSTALLED PER MANUFACTURER'S SPECIFICATIONS CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"5 WINDOW JAMB AT SIDING & STUCCO () () INTERIOR EXTERIOR 5/4 x 4 FIBER CEMENT TRIM WEATHER RESISTIVE BARRIER SIDING, INSTALL PER MANUFACTURER'S SPECIFICATIONS EXTERIOR SHEATHING; RE: STRUCT. (1) LAYER 1/2" GYP. BD. SELF-ADHERED FLASHING; WRAP INTO OPENING SHIM AS REQUIRED CONTINUOUS BACKER ROD AND SEALANT, 1/4" JOINT DO NOT OBSTRUCT WINDOW WEEPS VINYL WINDOW WITH LOW -E GLASS CONTINUOUS BACKER ROD AND SEALANT WOOD TRIM PER SPECS CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"4 WINDOW SILL AT SIDING & STUCCO () () INTERIOR EXTERIOR SHEATHING; RE: STRUCT. WEATHER RESISTIVE BARRIER SELF-ADHERED FLASHING; INSTALL PER MFR SPECS. CONT. BEAD OF SEALANT BETWEEN SHEATHING AND NAILING FIN CONTINUOUS BACKER ROD AND SEALANT FIBREX WINDOW WITH LOW-E GLAZING MINIMAL EXPANDING FOAM ; SEAL ROUGH OPENING (1) LAYER 1/2" GYP. BD. FLEXIBLE SELF-ADHERED FLASHING BELOW; TURN UP WALL 6" STONE CAP, SLOPED FOR DRAINAGE ADHERED MASONRY VENEER SYSTEM; INSTALL PER MFR. SPEC'S ADHERED STONE VENEER SYSTEM; INSTALL PER MFR. SPEC'S 3/8" CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"2 WINDOW JAMB AT 3" = 1'-0"3 WINDOW HEAD AT () () () () INTERIOR EXTERIOR SELF-ADHERED FLASHING; WRAP INTO OPENING SHIM AS REQUIRED CONTINUOUS BACKER ROD AND SEALANT, 1/4" JOINT DO NOT OBSTRUCT WINDOW WEEPS VINYL WINDOW WITH LOW-E GLASS 2X6 WOOD FRAMING, RE:STRUCTURAL WOOD TRIM PER SPECS GALVANIZED METAL FLASHING; OVERLAP SEAMS 4" AND FULLY SEAL SEAMS; COLOR TO MATCH FIELD ; SET IN SEALANT PREFINISHED METAL FLASHING, OVERLAP SEAMS 4" AND FULLY SEAL SEAMS; COLOR TO MATCH FIELD PRECAST STONE CAP, SLOPE TO DRAIN; RAKE MORTAR BETWEEN UNITS, FILL WITH BACKER ROD AND SEALANT ADHERED MASONRY VENEER SYSTEM; INSTALL PER MFR. SPEC'S 5/4 x 4 FIBER CEMENT TRIM NO SEALANT AT THIS LOCATION MORTAR SCRATCH COAT; INSTALL PER MFR. SPECS. (1) LAYER 1/2" GYP. BD. WEATHER RESISTIVE BARRIER (1) LAYER 15# FELT OVER WRB SELF-ADHERED FLASHING; INSTALL PER MFR SPECS. CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"1 WINDOW SILL AT () () () ADHERED MASONRY VENEER SYSTEM; INSTALL PER MFR. SPEC'S ADHERED STONE VENEER SYSTEM; INSTALL PER MFR. SPEC'S INTERIOR EXTERIOR ADHESIVE TAPE BY W.R.B. MFR.; LAP METAL FLASHING 5/4 x 4 FIBER CEMENT TRIM NO SEALANT AT THIS LOCATION CONTINUOUS BEAD OF SEALANT BETWEEN SHEATHING AND NAILING FIN SELF-ADHERED FLASHING OVERLAPPING WINDOW FLANGE; INSTALLED PER MANUFACTURER'S SPECIFICATIONS VINYL WINDOW WITH LOW-E GLASS SHIM AS REQUIRED GALVANIZED METAL FLASHING WITH HEMMED EDGE; OVERLAP SEAMS 4" AND FULLY SEAL SEAMS SEAL TO W.R.B. WITH MANUF'S SEAM TAPE PER MANUF'S REC.(FLASHING #1) 4" 1 1/4" FLASHING PROFILE MORTAR SCRATCH COAT; INSTALL PER MFR. SPECS. (1) LAYER 15# FELT OVER WRB SELF-ADHERED FLASHING; INSTALL PER MFR SPECS. WEATHER RESISTIVE BARRIER EXTERIOR SHEATHING; RE: STRUCT. (1) LAYER 1/2" GYP. BD. STONE HEADER PER ELEVATIONS STEEL LINTEL ANGLE -RE: STRUCTURAL CLOSED CELL SPRAY FOAM INSULATION TIGHT TO SHEATHING W/ 3-1/2" BLOWN IN OR BATT INSULATION, MIN. 3" = 1'-0"3 WINDOW HEAD AT 7 8 9 10 11 MASONRY MASONRY MASONRY SIDING, INSTALL PER MANUF. SIDING, INSTALL PER PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS SCALE: ISSUED FOR: APPROVED: 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 © NEO STUDIO As indicated PR O S P E C T R I D G E M U L T I F A M I L Y I2 5 A N D E P R O S P E C T R O A D FO R T C O L L I N S , C O L O R A D O 25-06 Author Checker ISSUE DATE NOT FOR CONSTRUCTION Approver 27