Loading...
HomeMy WebLinkAboutPlans - Irrigation Plan - 04/25/2025IRRIGATION NOTES IR1.00 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. IRRIGATION SCHEDULE SYMBOL MANUFACTURER MODEL NO.DESCRIPTION DETAIL NO. FEBCO 825YA RP BACKFLOW PREVENTER 1 N/S STRONG BOX SBBC-22AL BACKFLOW PREVENTER ENCLOSURE 2 HUNTER I2C-SS AND ICC-PED-SS W/ ICM-800 - 16 STATION MODEL ELECTRIC CONTROLLER 3 & 6 HUNTER SOLAR SYNC - WSS-SEN WEATHER SENSOR DEVICE 5 RAIN BIRD 44-LRC QUICK COUPLING VALVE 8 N/S MACDONALD AY 1/4 TURN - 1"MANUAL DRAIN VALVE 9 HUNTER ICV (1")MASTER CONTROL VALVE 10 LINE SIZE - 21 2'' AND SMALLER GATE VALVE 11 CST FSI-T10-001 (1")FLOW SENSOR 12 N/S OLDCASTLE / CARSON REFER TO SPECIFICATIONS AND DETAILS VALVE BOXES VARIOUS RAIN BIRD PEB WITH NIBCO BALL VALVE ELECTRIC CONTROL VALVE 13 RAIN BIRD RD-12-S-P30 WITH MPR SERIES NOZZLE HI-POP SPRAY HEAD 14 HUNTER ICZ-101-25 DRIP VALVE ASSEMBLY 15 TORO BLUE STRIPE POLY DRIP TUBING -3 4" MIN. WIDTH 15-17 N/S RAIN BIRD XERI-BUG DRIP EMITTERS 16 HUNTER / NIBCO ECO-ID-12 WITH NIBCO BALL VALVE DRIP LINE BLOW-OUT STUB AND INDICATOR HEAD 17 CLASS 200 BE - 21 2" & SMALLER PVC MAINLINE 6 TYPE K COPPER HARD COPPER PIPE 1 CLASS 160 PVC SLEEVING 7 WATER METER BY OTHERS A W FS M GPM CONTROL VALVE SIZE CONTROLLER & STATION NO. A (controller)NUMBER OF SPARE WIRES - 2 CONTROL AND 1 SPARE WIRES TO INDICATED CONTROLLER - SEE CONSTRUCTION NOTES3 1.DRAWINGS AND BASE INFORMATION - ALL BASE AND PLANTING INFORMATION HAVE BEEN PROVIDED BY STUDIO TERRA. THE CONTRACTOR IS RESPONSIBLE TO NOTIFY HYDROSYSTEMS*KDI OF ANY DISCREPANCIES BETWEEN THE UTILITY OR PLANTING PLANS AND THE IRRIGATION PLAN. IF CONTRACTOR FAILS TO NOTIFY HYDROSYSTEMS*KDI AND MAKES CHANGES TO THE IRRIGATION SYSTEM DESIGN, THEY ASSUME ALL COSTS AND LIABILITIES ASSOCIATED WITH THOSE FIELD CHANGES. REFER TO SPECIFICATIONS FOR ADDITIONAL PROJECT REQUIREMENTS. CONTACT IRRIGATION CONSULTANT FOR CURRENT SPECIFICATIONS IF NOT PROVIDED. 2.SYSTEM PRESSURE - HYDROSYSTEMS*KDI HAS CONTACTED THE LOCAL WATER DISTRICT THAT SERVES THIS SITE AND THEY HAVE BEEN TOLD THAT THE STATIC WATER PRESSURE IN THIS AREA SHOULD BE 86 PSI. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY PRESSURE PRIOR TO COMMENCING ANY CONSTRUCTION AND NOTIFY HYDROSYSTEMS*KDI OF ANY VARIANCE FROM THE STATED PRESSURE IMMEDIATELY. WRITTEN DOCUMENTATION OF PRESSURE TEST AND RESULTS SHALL BE PROVIDED TO HYDROSYSTEMS*KDI AT CONSTRUCTION ONSET. IF CONTRACTOR FAILS TO FIELD VERIFY PRESSURE AND/OR NOTIFY HYDROSYSTEMS*KDI OR ANY VARIATIONS FROM THIS PRESSURE, THEN THEY ASSUME ALL CONSTRUCTION AND ENGINEERING COSTS ASSOCIATED WITH SYSTEM MODIFICATIONS REQUIRED TO ACCOMMODATE ACTUAL SITE PRESSURE. THIS SYSTEM HAS BEEN DESIGNED FOR A REQUIRED STATIC PRESSURE OF 75 PSI MINIMUM. 3.IRRIGATION SYSTEM OPERATION INTENT - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO IRRIGATE THE ESTABLISHED LANDSCAPE WITHIN A 6 NIGHT PER WEEK, 6 HOUR PER NIGHT WATERING WINDOW. ESTABLISHMENT WATERING WILL REQUIRE UP TO TWICE AS MUCH IRRIGATION FOR A FOUR TO SIX WEEK PERIOD. THE DESIGN IS BASED ON THE FOLLOWING PROJECTED WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES ARE BASED ON A 30-YEAR AVERAGE WEATHER DATA AND WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND WEATHER CONDITIONS ABOVE AND BELOW THE AVERAGE VALUES UTILIZED. ORNAMENTAL PLANTINGS 0.77" PER WEEK PEAK SEASON NATIVE SEED MIXES 0.54" PER WEEK PEAK SEASON (TWO SEASONS) 4.EQUIPMENT INSTALLATION - IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED WITHIN PROPERTY LIMITS AND WITHIN LANDSCAPED AREAS. INSTALLATION SHALL BE COORDINATED WITH OTHER UTILITY WORK, ALL OTHER UTILITIES SHALL TAKE PRECEDENCE OVER IRRIGATION LOCATION. ANY EQUIPMENT OTHER THAN VALVE BOXES OR SLEEVING THAT CONTAINS PIPE OR WIRES SHOWN OUTSIDE OF THESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONLY. ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'-0" FROM EDGE OF ANY PAVED SURFACES UNLESS SPECIFICALLY INDICATED ON PLANS. BOXES INSTALLED IN OPEN TURF AREAS SHALL BE KEPT TO EDGES AND STAKED FOR REVIEW IF ALONG HIGH TRAFFIC AREAS. ALL VALVE BOXES SHALL BE PLACED A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALE. ALL VALVE BOXES WITHIN PAVEMENT SHALL BE TIER 15 RATED BOXES FOR HEAVY DUTY NON-DELIBERATE TRAFFIC. BOX LID COLOR SHALL MATCH ADJACENT MATERIALS, I.E. GREEN IN TURF, TAN IN WOOD MULCH, GRAY IN STONE MULCH, PURPLE FOR RECLAIMED WATER SYSTEMS (IF REQUIRED). REFER TO LANDSCAPE PLANS FOR MATERIAL COLORS AND TYPES. ALL BOXES SHALL BE INSTALLED TO BE FLUSH WITH GRADE AND IN AN ORDERLY MANNER. WHERE MORTAR PAVING LIDS ARE INSTALLED ABOVE BOXES, IRRIGATION BOX WITH LID SHALL BE LOWERED TO ACCOMMODATE PAVING LID. REFER TO LANDSCAPE FOR ADDITIONAL INFORMATION, TO BE INSTALLED PER MANUFACTURE RECOMMENDATIONS. 5.PIPING INSTALLATION - IRRIGATION PIPING SHALL MAINTAIN A MINIMUM DISTANCE FROM BUILDING FOUNDATIONS OF 5 FEET OR AS DESCRIBED IN SOILS REPORT, WHICHEVER IS GREATER. NO SPRAY IRRIGATION SHALL OCCUR WITHIN 10 FEET OF THE FOUNDATION. NO DRIP IRRIGATION SHALL OCCUR WITHIN 5 FEET OF THE FOUNDATION UNLESS SOIL MOISTURE SENSORS ARE INSTALLED ON VALVES SERVICING THESE AREAS. ALL IRRIGATION PIPING AND EMISSION DEVICES LOCATED ON TOP OF OR WITHIN BUILDING STRUCTURE SHALL CONFORM TO WATERPROOFING CONSULTANT REQUIREMENTS. PIPE ROUTING MAY BE SHOWN WITHIN THESE DISTANCES FOR GRAPHICAL CLARITY ONLY. 6.MANUAL DRAIN VALVES - CONTRACTOR TO INSTALL ONE MANUAL DRAIN VALVE ON PRESSURE SUPPLY LINE DIRECTLY DOWNSTREAM OF BACKFLOW PREVENTER AND AT ALL LOW POINTS AND DEAD ENDS OF PRESSURE SUPPLY PIPING TO ENSURE COMPLETE DRAINAGE OF SYSTEM. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THESE LOCATIONS IN-FIELD AND INSTALLATION LOCATIONS SHALL BE NOTED ON AS-BUILTS. 9.POP-UP SPRAY NOZZLES - CONTRACTOR TO INSTALL PLASTIC NOZZLES ON ALL POP-UP SPRAY HEADS. INSTALL 15 SERIES NOZZLES ON ALL HEADS SPACED AT 12' TO 14'. INSTALL 12 SERIES NOZZLES ON ALL HEADS SPACED 10' TO 11'. INSTALL 10 SERIES NOZZLES ON ALL HEADS SPACED AT 8' TO 9'. INSTALL 8 SERIES NOZZLES ON ALL HEADS SPACED AT 6' TO 7'. INSTALL 5' NOZZLES ON ALL HEADS SPACED AT 5'. INSTALL SIDE STRIP NOZZLES ON ALL HEADS WITH AN "S" DESIGNATION AND RIGHT AND LEFT CORNER STRIP NOZZLES ON ALL HEADS WITH AN "L" OR "R" DESIGNATION. AT SPACING SHOWN. VARIABLE ARC NOZZLES SHOULD BE UTILIZED ADJACENT TO CURVILINEAR SHRUB BEDS OR FOR ANY ANGLES THAT ARE NOT A STANDARD NOZZLE ANGLE. 10.DRIP IRRIGATION - REFER TO IRRIGATION DETAIL SHEET FOR AND PLACEMENT. 11.UNLABELED PIPING - ALL UNLABELED LATERAL PIPING SHALL BE 1" MINIMUM UNLESS OTHERWISE NOTED. 12.SLEEVING - ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. SLEEVING SHALL BE INSTALLED IN THE SIZES AND QUANTITIES SHOWN ON PLANS OR BASED ON THE SCHEDULE BELOW. WHERE SLEEVES ARE SHOWN, BUT NOT LABELED, FOLLOW THE SCHEDULE BELOW. ALL MAINLINE, CONTROL WIRES AND DRIP LINES UNDER PAVED SURFACES ARE TO BE INSTALLED IN SLEEVING. ALL MAINLINE SLEEVE LOCATIONS TO INCLUDE A SEPARATE WIRE SLEEVE. SLEEVED PIPE SIZE/WIRE QUANTITY REQUIRED SLEEVE SIZE & (QUANTITY) 3 4" - 114" PIPING 2" PVC (1) 11 2" - 2" PIPING 4" PVC (1) 13.SPARE CONTROL WIRES - CONTRACTOR SHALL EXTEND THREE SPARE WIRES (ONE COMMON AND 2 CONTROL WIRES) FROM EACH CONTROLLER TO THE END OF THE MAINLINE SERVING THAT CONTROLLER OR AS SHOWN ON THE PLANS. INSTALL SPARE WIRES IN 10" ROUND VALVE BOX WITH QUICK COUPLING VALVE. REFER TO SPECIFICATIONS FOR WIRE COLOR. SEE IRRIGATION SCHEDULE FOR ADDITIONAL INFORMATION. 14.ADJUSTMENT - CONTRACTOR SHALL FINE TUNE/ADJUST THE IRRIGATION SYSTEM TO REDUCE/AVOID OVERSPRAY ONTO HARD SURFACES BY ADJUSTING NOZZLE DIRECTION AND NOZZLE RADIUS. 17.PLANS AND SPECIFICATIONS - CONTRACTOR RESPONSIBLE TO ENSURE WORK CONFORMS TO PLANS AND SPECIFICATIONS. AT ONSET OF CONSTRUCTION, VERIFY PLANS ARE CURRENT. DO NOT CONSTRUCT ANY PORTIONS OF THE IRRIGATION OFF OF PLANS MARKED NOT FOR CONSTRUCTION OR FOR REVIEW ONLY. FAILURE TO VERIFY CURRENT PLANS MAY RESULT IN RECONSTRUCTION AT CONTRACTOR'S EXPENSE. WHERE REQUIRED BY CITY, TOWN OR WATER DISTRICT ENTITY, CONTRACTOR SHALL CONSTRUCT ONLY OFF PLANS STAMPED WITH APPROVAL. REVISIONS TO APPROVED OR STAMPED PLANS SHALL CONFORM TO FIELD CHANGE PROCEDURES AND DOCUMENTATION. 20.SIMULTANEOUS ZONE OPERATION - THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO OPERATE MULTIPLE ZONES SIMULTANEOUSLY BASED ON INDIVIDUAL ZONE FLOW. THE DESIGN IS INTENDED TO OPERATE MULTIPLE VALVES, UP TO THE MAXIMUM FLOW IN THE POINT OF CONNECTION NOTE. REFER TO CONTROLLER SPECIFICATION FOR MAXIMUM SIMULTANEOUS VALVE COUNT. 21.BACKFLOW DEVICES: ALL CONNECTION COMPONENTS AND BACKFLOW DEVICES SHALL BE LEAD-FREE. CONTRACTOR SHALL CONTACT WATER SERVICE PROVIDER FOR ANY ADDITIONAL REQUIREMENTS REGARDING BACKFLOW TESTING. 22.WATER BUDGETS AND PROJECTIONS - HYDROSYSTEMS-KDI HAS BASED THE IRRIGATION DESIGN AND THE ASSOCIATED PROJECTED WATER USE UPON SUCH FACTORS AS CITY OR WATER DISTRICT IMPOSED REQUIREMENTS, PUBLISHED PLANT SPECIES WATER NEEDS, SELECTED IRRIGATION METHOD EFFICIENCIES AS REPORTED BY INDEPENDENT TESTING FACILITIES, HISTORICAL WEATHER DATA FOR THE PROJECT LOCATION, AND PROPER MAINTENANCE PROCEDURES. HYDROSYSTEMS*KDI IS NOT RESPONSIBLE, AND ACCEPTS NO RESPONSIBILITY, FOR THE ACTUAL WATER USAGE VARIATION THAT IS A RESULT OF FIELD MODIFICATIONS TO THE SYSTEM NOT MATCHING CONSTRUCTION DOCUMENTS, IMPROPER MAINTENANCE, WASTE DUE TO SYSTEM DAMAGE OR VANDALISM, OR WEATHER CONDITIONS THAT DEVIATE FROM PUBLISHED 30 YEAR HISTORICAL AVERAGES. 23.PRESSURE TESTING - CONDUCT MAINLINE TEST IN PRESENCE OF CONSULTANT. ARRANGE FOR PRESENCE OF CONSULTANT 48 HOURS IN ADVANCE OF TESTING. SUPPLY FORCE PUMP AND ALL OTHER TEST EQUIPMENT. COMPRESSED AIR SHALL NOT BE USED FOR PRESSURE TESTING SYSTEM. 23.1.AFTER BACKFILLING, AND INSTALLATION OF ALL CONTROL VALVES, FILL PRESSURE SUPPLY LINE WITH WATER, AND PRESSURIZE TO 40 PSI OVER THE DESIGNATED STATIC PRESSURE OR 120 PSI, WHICHEVER IS GREATER, FOR A PERIOD OF 2 HOURS. 23.2.LEAKAGE, PRESSURE LOSS - TEST IS ACCEPTABLE IF NO LOSS OF PRESSURE IS EVIDENT DURING THE TEST PERIOD. 23.3.LEAKS - DETECT AND REPAIR LEAKS. 23.4.RETEST SYSTEM UNTIL TEST PRESSURE CAN BE MAINTAINED FOR DURATION OF TEST. 23.5.BEFORE FINAL ACCEPTANCE, PRESSURE SUPPLY LINE SHALL REMAIN UNDER PRESSURE FOR A PERIOD OF 48 HOURS. 23.6.PRESSURE TEST SHALL BE SCHEDULED AND PASSED PRIOR TO SCHEDULING OF SUBSTANTIAL COMPLETION WALK-THROUGH. IRRIGATION CONSTRUCTION NOTES BDR SUBMITTAL 4 2025.04.25 DC M RP RP T T T T T T T T T WA T WA T WA T SA N SA N SA N SA N WAT WAT WAT WA T WA T WA T WA T WA T WA T WA T WA T WA T EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C EL E C WA T WA T WA T WA T WA T WA T WA T WA T WA T WA T WA T WA T WA T M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M W E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM COMM CO M M SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS CONIFER STREET 80 ' - 0 " ' R . O . W . ' R.O.W. 83 ' - 0 " ' R . O . W . C CABLE CABLEVAULT CABLE CABLEVAULT WV WV S S W 3A 3A (1)4''(1)2'' (1)4''(2)2''(1)4'' (2)2'' (1)4''(1)2''(1)4'' (2)2'' (1)4''(2)2'' (1)4''(1)2'' (1)2'' (1)2'' (1)2'' (1)2''(1)2''(1)2''(1)2''(1)2'' 1'' 1'' 1'' 1'' 1'' (1)2''(1)2'' (1)2'' (1)4'' (2)2'' (1)4'' (2)2'' 50.00 dr 1" A9 10 1" A10 8 1" A11 dr 1" A1 dr 1" A2dr1" A3 dr 1" A4 dr 1" A5 dr 1" A6 9 1" A7 8 1" A8 5 1" A12 9 1" A13 (1)4''(1)2'' M AFS (1)4''(1)2'' L R S 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 010 20 FT SCALE: 1" = 20'-0" 20 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CONTROLLER LOCATION "A" PEDESTAL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION COUNT), REMOTE READY, AT INDICATED LOCATION. 120 VOLT POWER IS AVAILABLE WITHIN 50 LF. OF CONTROLLER LOCATION FROM TRANSFORMER BY OTHERS RE:ELECTRICAL. ELECTRICAL METER, WIRE/CONDUIT, STEP-DOWN TRANSFORMER (IF REQUIRED) AND POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. LOCATE SHIELDED CABLE FROM FLOW SENSOR AND CONNECT TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. LOCATE MASTER VALVE WIRES WITH SPARES AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. MOUNT ONE WEATHER SENSOR ON POLE WHERE THERE IS 20 FT. OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE. CONNECT SENSOR RECEIVER WIRES TO IRRIGATION CONTROLLER SENSOR PORT THROUGH CONDUIT. FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER OR OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. POINT OF CONNECTION #1 - 3/4" PEAK FLOW REQUIREMENT: 10 GPM. REQUIRED STATIC PRESSURE: 75 PSI CONTRACTOR SHALL TIE ONTO 3/4'' COPPER STUB-OUT DOWNSTREAM OF METER PIT AT 54'' DEPTH IN THIS APPROXIMATE LOCATION. INSTALLATION OF TAP, SERVICE LINE, METER PIT AND STUB TO THIS LOCATION IS BY OTHERS RE=CIVIL. INSTALL ONE 3/4'' METER PER FORT COLLINS CITY SPECIFICATIONS AND STANDARDS. CONNECT TO STUB AND EXTEND 3/4'' TYPE K SOFT COPPER AT 54'' MINIMUM DEPTH TO BACKFLOW PREVENTER LOCATION. INSTALL ONE 3/4'' STOP AND WASTE VALVE, ONE 3/4'' REDUCED PRESSURE BACKFLOW PREVENTER WITH PROTECTIVE ENCLOSURE, ONE 3/4" MANUAL DRAIN VALVE, ONE 3/4" FLOW SENSOR, ONE GATE VALVE, ONE QUICK COUPLING VALVE, ONE MASTER VALVE, AND EXTEND PVC MAINLINE AS SHOWN. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14# WIRE (TWO ORANGE AND TWO BLUE) AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. SEE DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES, PERMITS AND INSPECTIONS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR. FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. A1 A 1 IRRIGATION PLAN IR1.01 The Natural Habitat Buffer Zone is intended to be maintained in a native landscape. Please see Section 5.6 of the Land Use Code for allowable uses within the Natural Habitat Buffer Zone MITIGATION PLAN SUMMARY ·Mitigation for the impacts of development through management and enhancement of the area 50’ from the top of the embankment of the drainage ditch will be performed to develop a Natural Habitat Buffer Zone (NHBZ) per City of Fort Collins Code. ·Mitigation will be focused on enhancement of existing non-functioning to functioning-impaired areas within this NHBZ. ·The limits of disturbance will be established ahead of construction and clearly marked in the field to limit unnecessary impacts. ·Tracking of equipment within the proposed NHBZ will be minimized to the greatest extent possible, and where necessary, will be mitigated through the use of cribbing, wide tracks, and timed access (i.e., when soils are not wet and susceptible to compaction). ·Vegetation removal will be timed in such a way and under the consultation of a biologist so as to minimize impacts to local species. ·Erosion control will be maintained in effective operating conditions both during and following the completion of construction until monitoring indicates that revegetation has established enough to prevent erosion and sediment drift. ·Native vegetation will be planted and maintained within the NHBZ according to the Landscape Plan. ·Weeds and dormant vegetation will be managed within the NHBZ according to the Landscape Plan and Buffer Mitigation Plan. ·Long-term monitoring and assessment with adaptive management in the NHBZ will be provided for a minimum of 3 years to ensure mitigation goals, as defined in the Buffer Mitigation Plan, are met. ·Long-term monitoring goals will also include a minimum survival rate of 80% for all planted vegetation on the site, even outside of the NHBZ. BDR SUBMITTAL 4 2025.04.25 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. PVC PRESSURE MAINLINE REFER TO IRRIGATION SCHEDULE NOTE: ·CONCRETE PAD PENETRATIONS TO BE 1" LARGER THAN TUBING DIAMETER. ·REFER TO ENCLOSURE DETAIL FOR CONCRETE PAD DIMENSIONS. ·DIAMETER OF FITTINGS, NIPPLE AND TUBING SHALL EQUAL DIAMETER OF BACKFLOW PREVENTER UNLESS NOTED OTHERWISE. BRONZE UNION - SWxSW 6" THICK CONCRETE PAD - LENGTH AS REQUIRED, 30" MIN. WIDTH. TOP OF SLAB TO BE 1" ABOVE FINISH GRADE. ADJUSTABLE CAST IRON STOP BOX - TYLER OR EQUAL PROTECTIVE ENCLOSURE - REFER TO DETAIL REDUCED PRESSURE BACKFLOW PREVENTER CxM ADAPTER (TWO REQUIRED) QUICK COUPLING VALVE - INSTALL AS PER QCV DETAIL 12" SOIL FILTER FABRIC COVERING GRAVEL SUMP STOP & DRAIN VALVE - LINE SIZE 3 4" CRUSHED GRAVEL SUMP - 2 CU. FT. SERVICE LINE FROM WATER METER 12"EQ EQ TYPE "K" RIGID COPPER BACKFLOW PREVENTER 13/4" - 2" SYSTEMS WITH PVC CONNECTION CL EQ EQ 6"16.25"6" Y BFP MODEL/SIZE ENCLOSURE MODEL X Y FEBCO 825Y 3 4" & 1"SBBC-30AL 30"42" FEBCO 825Y 112" & 2"SBBC-45AL 45"57" FEBCO 825YA 3 4" & 1"SBBC-22AL 22''34" FEBCO 825YA 112" & 2"SBBC-30AL 30"42" NOTES: ·PAD PENETRATIONS FOR BACKFLOW PREVENTER RISERS TO BE 1" LARGER THAN RISER DIAMETER. ·TOP SURFACE OF CONCRETE PAD SHALL BE 1" ABOVE FINISH GRADE. ·INSTALL ENCLOSURE ANCHORS AS PER MANUFACTURER'S RECOMMENDATIONS. ·PROVIDE OWNER WITH KEYED PADLOCK FOR ENCLOSURE. 30" X CL 1"5" EQ 6" Y EQ 6" CL CONCRETE PAD STRONGBOX ENCLOSURE ELEVATION PLAN VIEW 2STRONGBOX - 3/4" - 2" SYSTEMS BACKFLOW ENCLOSURE 0.5% SLOPE A NOTES: ·CONTRACTOR TO GROUND AND PROVIDE SURGE PROTECTION FOR CONTROLLER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND GROUND ROD(S) SHOWN. ·CONTROLLER GROUNDING SHALL COMPLY W/ MANUFACTURER'S SPECIFICATIONS. ·INSTALL A DISCONNECT SWITCH AND 120 VOLT GFIC RECEPTACLE WITHIN PEDESTAL. ·ALL ELECTRICAL WORK TO CONFORM TO LOCAL CODE. 6" 18" 6"6" PLAN VIEW 5" 1" CLOSEST IRRIGATED AREA 120 VOLT SERVICE GFI & POWER SWITCH CONTROLLER INSTALL 4" HT. SELF ADHESIVE VINYL LETTERING CORRESPONDING WITH CONTROLLER # ON OUTSIDE SURFACE OF ENCLOSURE DOOR. CONTROL WIRES - NEATLY BUNDLE WIRING & SECURE W/ LOCKING WIRE TIES 3 4" NON-METALLIC LIQUIDTITE CONDUIT W/ MALE ADAPTERS (2) AND LOCK RINGS, WASHERS CONCRETE PAD FINISH GRADE 5 8"x8' COPPER - CLAD GROUNDING ROD W/ BRONZE CLAMP & 10" ROUND VALVE BOX (TYPICAL) #6 BARE COPPER GROUNDING WIRE 1" PVC CONDUIT W/ SWEEP ELL - GROUND WIRE 3" PVC CONDUIT W/ SWEEP ELL - CONTROL WIRES PROVIDE 48" LENGTH OF ALL SPARE WIRES WITHIN PEDESTAL, NEATLY COILED. 3 4" PVC CONDUIT W/ SWEEP ELL - 120v SERVICE PREFABRICATED ENCLOSURE FRONT VIEW EXTERNAL SIDE VIEW 3ELECTRIC CONTROLLER PEDESTAL - FRONT OPENING - TYPICAL NOTE: MOUNT RAIN SENSOR RECEIVER PER CONTROLLER DETAIL. FINISH GRADE 12' MIN. 48" MIN. 11 2" DIAMETER SCH. 40 GALVANIZED STEEL POST W/ 11 2" GALVANIZED FIPT CAP 3" SELF-LEVELING WEATHER SENSOR - INSTALL PER MANUFACTURE'S RECOMMENDATIONS. WEATHER SENSOR 5POLE MOUNTED - Self-Leveling 4-6" BODIES: 18" 12" BODIES: 24" CONTROL WIRE BUNDLE OR TWO WIRE COMMUNICATION CABLE (PER SPECIFICATIONS) 24" SPRAY HEAD LATERAL PIPING OR DRIP LINE HEADER. FINISH GRADE ROTOR LATERAL PIPING BACKFILL MATERIAL (TYP.) 4-6" BODIES: 14" 12" BODIES: 18" MAINLINE NOTE: REFER TO TECHNICAL SPECIFICATIONS FOR MINIMUM TRENCH WIDTHS. 624" MAINLINE TRENCH IRRIGATION DETAILS IR1.02 MIN. CONTINUOUS CONDUIT FROM CONTROLLER TO LANDSCAPE AREA FINISH GRADE 3'-0" CONTROLLER ENCLOSURE 1'-0" 8'-0" 15'-0" GROUND ENHANCEMENT MATERIAL PER COPPER GROUNDING PLATE 4''x96''x 0.0626'' #6 CONTINUOUS SOLID BARE COPPER WIRE (TYP.) 5/8" x 8 FT. COPPER-CLAD GROUNDING ROD - INSTALL IN LANDSCAPE AREA #6 CONTINUOUS SOLID BARE COPPER WIRE (TYP.) CADWELD GT1161G "ONE SHOT" WELD MANUFACTURER'S RECOMMENDATIONS BDR SUBMITTAL 4 2025.04.25 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. FINISH GRADE 2" 3" 10" ROUND VALVE BOX. BRAND "GV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC. 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF TOP OF 6" PVC ACCESS SLEEVE∅ 6" CLASS 200 PVC SLEEVE BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE SCH. 40 PVC MALE ADAPTER (2) - SIZE TO EQUAL GATE VALVE DIAMETER UNDISTURBED SOIL 11GATE VALVE 2.5" & SMALLER - X-HANDLE NO FITTINGS INCLUDING REDUCER BUSHINGS, TEES, ELLS, ETC, SHALL BE INSTALLED WITHIN "METER RUN" DISTANCE. DIAMETER OF FLOW SENSOR TEE AND "METER RUN" PIPING SHALL BE EQUAL. NO REDUCER BUSHINGS, ADAPTERS, ETC. SHALL BE INSTALLED WITHIN FLOW SENSOR TEE. DATA CABLE SPLICE CONSISTING OF WIRE NUTS AND PREFORMED SUPER SERVISEAL SPLICE KIT. FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSIONS AS REQUIRED. BRAND "FS" INTO VALVE BOX LID. REFER TO TECHNICAL TO TECHNICAL SPECIFICATIONS SPECIFICATIONS. VALVE BOX SHALL NOT REST DIRECTLY ON FLOW SENSOR CABLE. TEE STYLE FLOW SENSOR. REFER TO PLAN & SCHEDULE FOR SIZING, MANUFACTURER, & MODEL. DATA CABLE TO CONTROLLER SENSOR INPUTS PER MANUFACTURER RECOMMENDATION. PROVIDE ADDITIONAL CABLE WITHIN BOX TO ALLOW REMOVAL OF SENSING UNIT FROM BOX FOR MAINTENANCE PURPOSES. 3/4" GRAVEL SUMP - 2 CU. FT. PVC PRESSURE MAINLINE - REFER TO PLAN FOR DIAMETER. FLOW 10x PIPE DIA.5x PIPE DIA. METER RUN FLOW SENSOR 12VIA DATA CABLE - TEE STYLE FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSION - BRAND "MV" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SLIPxMIPT SCH. 40 PVC ADAPTER (2) PRESSURE MAINLINE 3 4" CRUSHED GRAVEL SUMP - 2 C.F. ELECTRIC MASTER CONTROL VALVE MASTER VALVE 1024V - Small - Typical FINISH GRADE APPLY TEFLON TAPE TO ALL THREADED NIPPLES 3" 2" 10" ROUND VALVE BOX BRAND "QC" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF BOTTOM OF QCV LID 1" BRASS NIPPLE LENGTH AS REQUIRED LINE SIZE BRASS COUPLING 12"x12" REBAR STABILIZING STAKE TYPICAL TWO SIDES PER QUICK COUPLING VALVE LOCATION LASCO #G 13S-212 UNITIZED SWING JOINT W/ BRASS INSERT STABILIZER ELBOW. PROVIDE WITH 1" MIPT INLET PRESSURE MAINLINEx1" PVC SERVICE TEE - SOLVENT WELD OR GASKETED FITTING REFER TO SPECIFICAIONS QUICK COUPLING VALVE QUICK COUPLING VALVE 8LASCOSWING - TYPICAL FINISH GRADE APPLY TEFLON TAPE TO ALL MALE THREADED PVC FITTINGS AND ALL NIPPLES 3 4" CRUSHED GRAVEL SUMP 1 CU. FT. 2" VALVE MARKER 10" ROUND VALVE BOX - BRAND THE LETTER "D' IN LID. REFER TO TECHNICAL SPECIFICATIONS. 2" CL 200 PVC ACCESS SLEEVE - LENGTH AS REQUIRED 1" FxF BRASS 90 ELL (2) 1"xCL BRASS NIPPLE (2) 1"x6" BRASS NIPPLE 1" BRASS 1/4 TURN CURB STOP 1" MxF SCH. 40 PVC 90 ELL SOIL BLANKET COVERING SUMP 1"x4" PVC NIPPLE SCH. 80 3 4" CRUSHED GRAVEL SUMP. SEE TECHNICAL SPECIFICATIONS FOR SUMP SIZE PVC PRESSURE MAINLINE. REFER TO TRENCH DETAIL. MANUAL DRAIN VALVE 9TYPICAL IRRIGATION DETAILS IR1.03 B A ROUGH GRADE C NOTE: ·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ON PLAN. ·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES VERTICALLY. ·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A "V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING. ·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, POND LINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVIL WORK AT APPROXIMATE LOCATIONS SHOWN. ·AN INDIVIDUAL SLEEVE SHALL CONTAIN NO MORE THAN ONE PIPE OR WIRE BUNDLE. PAVED SURFACE CURB AND GUTTER (IF APPLICABLE) 2" PVC PIPE SLEEVE MARKER - INSTALL AT BOTH ENDS OF EACH SLEEVE LOCATION AND EXTEND AT LEAST 3' ABOVE GRADE. SPRAY EXPOSED PORTION OF MARKER WITH GREEN FLUORESCENT PAINT. REMOVE AT FINAL INSTALL. SEAL ENDS OF SLEEVE WITH CLOTH DUCT TAPE (TYPICAL) PVC OR HDPE SLEEVING (TYPICAL) 24" MIN. 12" MIN. 36" MIN. IRRIGATION SLEEVING 7TYPICAL BDR SUBMITTAL 4 2025.04.25 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. FINISH GRADE DEFLECT TUBING TO PERMIT ENTRY THROUGH BOTTOM OF VALVE BOX. 12" POP-UP SPRAY HEAD WITH CHECK VALVE AND COLOR STEM, & SWING PIPE (ZONE OPERATIONAL INDICATOR)PLANT MATERIAL 3 4" PVC BALL VALVE WITH 3 4" PVC INSxMIPT ADAPTER AND S.S. CLAMP 3 4" DRIP TUBING - COIL SUFFICIENT LENGTH IN BOX TO EXTEND HOSE ADAPTER OUTSIDE OF VALVE BOX. 3 4" WASHED RIVER ROCK SUMP (1 CU. FT.) INSERT TEE WITH CLAMPS 10" ROUND VALVE BOX WITH COVER - BRAND "DB" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SECTIONPLAN DISTANCES VARY: CONTRACTOR SHALL LOCATE FLUSH VALVE BOX TO BE SCREENED BY PLANT MATERIAL AND ACCESSIBLE. OPERATIONAL INDICATOR SHALL BE LOCATED FOR EASY VISIBILITY DURING OPERATION PLANT MATERIAL INDICATOR HEAD PLANTER BED WALL OR EDGER FLUSH VALVE POLY PIPE FROM EXHAUST HEADER OR DRIP LATERAL DRIP FLUSH VALVE 17WITH OPERATIONAL INDICATOR NOTE: INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN ENTIRE ASSEMBLY WITHIN BOX. NO VALVE BOX EXTENSIONS WILL BE ACCEPTED. PROVIDE 3"-4" CLEARANCE BETWEEN TOP OF CONTROL VALVE SOLENOID AND BOTTOM OF VALVE BOX LID. TOP OF VALVE BOX TO BE FLUSH WITH FINISH GRADE. VALVE BOX SHALL NOT REST ON DRIP TUBING. PVC MAINLINE PVC SCH. 40 TEE OR ELL PVC SCH. 80 NIPPLE 3" MIN. DEPTH 3 4" WASHED GRAVEL VALVE SIZE MIPTxINS. PVC ADAPTER JUMBO VALVE BOX - BRAND BOX LID W/ CONTROLLER AND STATION NUMBER - REFER TO TECHNICAL SPECIFICATIONS. WATERPROOF SPLICE 24" COILED WIRE PVC SCH. 80 NIPPLE PVC SCH. 40 ELL FINISH GRADE LINE SIZE PVC BALL VALVE 3" MIN.DRIP VALVE ASSEMBLY (SEE SCHEDULE) STAINLESS STEEL WORM GEAR OR PINCH CLAMP VALVE SIZE POLY PIPING - SWEEP TO SPECIFIED DEPTH 12" POP-UP SPRAY HEAD WITH CHECK VALVE, PURPLE STEM & SWING PIPE (ZONE OPERATIONAL INDICATOR) INSERT TEE WITH CLAMPS DRIP VALVE 1524V - POLY LATERAL NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE SWING. ·JOINT ASSEMBLY SHALL BE ATTACHED TO BOTTOM SPRAY HEAD INLET ONLY. ·APPLY TEFLON TAPE TO ALL MALE PVC THREADED FITTINGS AND NIPPLES. PVC LATERAL PIPING W/ SCH. 40 PVC LINE SIZEx12" SLIPxFIPT FITTING 12" MxF SCH. 40 PVC 90d ELL 12"x6" SCH. 80 PVC NIPPLE 12" MxF SCH. 40 PVC 90d ELL (2 REQUIRED) 12" HI-POP SPRAY HEAD CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE SET BOTTOM OF CAP AT GRADE 6" 14HI-POP SPRAY HEAD SWING JOINT - PVC IRRIGATION DETAILS IR1.04 NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. PVC LATERAL - 45 ELL TO SPECIFIED DEPTH SCH. 40 PVC REDUCING MALE ADAPTER RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY. PROVIDE 12" CONTINUOUS COILS OF ALL "MAINTENANCE" SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX PVC BALL VALVE - FIPTxFIPT 3 4" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED SERVICE TEE - SOLVENT WELD OR GASKETED FITTING - REFER TO SPECIFICATIONS CONTROL WIRE BUNDLE ELECTRIC CONTROL VALVE 4" FINISH GRADE 13ELECTRIC CONTROL VALVE 24V - PVC Lateral PLANT SIZE EMITTER FLOW RATE EMITTER QTY. AT MULCHED BED LOCATIONS - SINGLE HYDROZONE EMITTER QTY. AT MULCHED BED LOCATIONS - MIXED HYDROZONE EMITTER QTY. AT NATIVE SEED LOCATIONS 1 - 2 GALLON MATERIAL 0.5 GPH ONE EACH VERY LOW - ONE EACH, LOW - ONE EACH, MODERATE - TWO EACH ONE EACH 5 GALLON MATERIAL 0.5 GPH TWO EACH VERY LOW - ONE EACH, LOW - TWO EACH, MODERATE - THREE EACH TWO EACH 112" CALIPER TREE 1.0 GPH THREE EACH VERY LOW - TWO EACH, LOW - THREE EACH, MODERATE - FIVE EACH FOUR EACH 2" CALIPER TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH, MODERATE - SIX EACH SIX EACH 212" CALIPER TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH, MODERATE - EIGHT EACH EIGHT EACH 3" CALIPER TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH, MODERATE - SIX 2.0 GPH TEN EACH 312" CALIPER TREE 1.0 GPH NINE EACH VERY LOW - SEVEN EACH, LOW - NINE EACH, MODERATE - SEVEN 2.0 GPH ELEVEN EACH 4" CALIPER TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH, MODERATE - EIGHT 2.0 GPH TWELVE EACH 6 FT. CONIFEROUS TREE 1.0 GPH FOUR EACH VERY LOW - THREE EACH, LOW - FOUR EACH, MODERATE - SIX EACH SIX EACH 8 FT. CONIFEROUS TREE 1.0 GPH SIX EACH VERY LOW - FOUR EACH, LOW - SIX EACH, MODERATE - EIGHT EACH NINE EACH 10 FT. CONIFEROUS TREE 1.0 GPH EIGHT EACH VERY LOW - SIX EACH, LOW - EIGHT EACH, MODERATE - SIX 2.0 GPH TWELVE EACH 12 FT. CONIFEROUS TREE 1.0 GPH TEN EACH VERY LOW - EIGHT EACH, LOW - TEN EACH, MODERATE - EIGHT 2.0 GPH FOURTEEN EACH NOTES: ·INSTALL EMITTERS ON OPPOSING SIDES OF ROOTBALL. THREE OR MORE EMITTERS SHALL BE EQUALLY SPACED AROUND ROOT BALL. ·EMITTERS ARE TO BE INSTALLED TO CLEAR SURFACE BY A MINIMUM OF 1" AND A MAXIMUM OF 2". ·FLUSH ALL LINES THOROUGHLY, INCLUDING EMITTER MICRO-TUBING PRIOR TO EMITTER INSTALLATION. ·IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL BOTH EMITTERS ON UPHILL SIDE OF ROOT BALL. ·EMITTERS SHALL BE SELF-FLUSHING, PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE WITHIN TECHNICAL SPECIFICATIONS. ·DRIP VALVE ZONES ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS (HYDROZONES) AND SUN EXPOSURE. ·CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. ·SITE CONDITIONS MAY DICTATE THAT MULTIPLE SUN EXPOSURES ARE VALVED TOGETHER DURING THE DESIGN PROCESS. CONTRACTOR SHALL ADJUST EMITTER SCHEDULE AS FOLLOWS: ··EMITTER QUANTITIES SHALL REMAIN THE SAME BUT EMITTER GALLONAGES SHALL BE DOUBLED FOR PLANTS WITH SOUTH AND WEST EXPOSURES. ··EMITTER QUANTITIES AND GALLONAGE SHALL BE AS SHOWN IN SCHEDULE FOR PLANTS WITH NORTH AND EAST EXPOSURES. ··PLANTINGS WITH NORTH AND EAST EXPOSURE SHALL DICTATE VALVE RUN-TIMES AND CONTRACTOR SHALL ADJUST SCHEDULING ACCORDINGLY. DOWN 4:1(+)-SLOPE SECTION 10" MIN 4"-6" PLANTING BACKFILL MATERIAL POLY DRIP TUBING PLANT ROOTBALL EMITTER - STAKE TO EDGE OF ROOTBALL EMITTER MICRO-TUBING - 60" MAXIMUM LENGTH PLANT MATERIAL EMITTER - REFER TO SCHEDULE FOR EMITTER QUANTITY. REFER TO SPECIFICATIONS FOR MANUFACTURER AND MODEL NUMBER. MULCH LAYER EMITTER MICRO-TUBING POLY DRIP TUBING - RE: TECHNICAL SPECIFICATIONS 6" 10 GAUGE JUTE STAKE OR APPROVED EQUAL PLAN 16DRIP EMITTER BELOW GRADE BDR SUBMITTAL 4 2025.04.25 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 13949 W. Colfax Ave, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management DIRECTORY IRRIGATION SCHEDULE IR1.00 IRRIGATION NOTES IR1.00 IRRIGATION PLANS IR1.01 IRRIGATION DETAILS IR1.02 - IR1.04 IRRIGATION CHARTS IR1.05 CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. R Know what's below. Call before you dig. IRRIGATION CHARTS IR1.05 WATER USE CHART C1 HYDRAULICS CHART C2 CONTROLLER CHART C3 BDR SUBMITTAL 4 2025.04.25