HomeMy WebLinkAboutReports - Utilities - 04/15/2025 WATER CALCULATIONS LOAD VALUE TOTAL LOAD VALUE TOTAL FIXTURE QUANTITY FIXTURE COLD HOT VALUE UNITS 13 WATER CL❑SET(FLUSH VALVE) 10 — 10 130 5 URINAL 5 — 5 25 10 LAVATORY 1. 5 1. 5 2 20 3 SINK 1. 5 1. 5 2 6 2 MOP SINK 2. 25 2. 25 3 6 3 ELECT DRINK F❑UNTAIN 0. 25 — 0. 25 0. 75 6 COFFEE/REF 0. 5 — 0. 5 3 10 HOSE BIB ALLOWANCE 2. 5 — 2. 5 25 TOTAL NUMBER OF FIXTURE UNITS = 215. 75 @ 94 GPM PRESSURE @ METER = 70 PSI — 10 PSI (BFP) — 4 PSI (ML) = 56 PSI USE NEW 1-1/2' COMPOUND WATER METER, 2-1/2' BACKFL❑W PREVENTER w/ 2-1/2' MAIN BUILDING LINE. 56 — 130 + (25 x . 43)7 = 15. 25 PSI ALLOWABLE L❑SS/100 FEET OF TOTAL DEVELOPED LENGTH OF PIPEi 100 x 15. 25 / 600 FEET = 2. 5 PSI PLUMBING CONTRACTOR TO VERIFY AND COORDINATE EXACT STREET PRESSURE AND N❑TIFY ENGINEER OF ANY DISCREPANCIES. PLUMBING CONTRACTOR TO PROVIDE A PRESSURE REDUCING VALVE (PRV) ON CITY SIDE OF WATER METER IF THE STREET PRESSURE EXCEED 80 PSI, PRV TO BE SET @ 80 PSI PLUMBING CONTRACTOR TO PROVIDE AND INSTALL A WATTS #LF909 OR EQUAL REDUCED PRESSURE PRINCIPLE BACKFLDW PREVENTER SAME SIZE AS LINE C❑NNECTING TO IT INSIDE OF BUILDING. BACKFLDW PREVENTER SHALL BE READILY ACCESSIBLE FOR INSPECTION. 'BEFORE THE LOCAL JURISDICTION WILL ACCEPT AN INSTALLED BACKFL❑W DEVICE FOR APPROVAL, THE F❑LLOWING MUST BE ACC❑MPLISHED. THE DEVICE MUST BE TESTED BY A STATE CERTIFIED BACKFL❑W TESTER AND TEST RESULTS FORWARDED TO THE LOCAL JURISDICTI❑N BACKFL❑W SPECIALIST. THE LOCAL JURISDICTI❑N WILL PR❑VIDE AN UP—TO—DATE LIST OF CERTIFIED TESTERS FROM WHICH TO BE SELECTED. TESTER FEES WILL BE AT THE EXPENSE OF THE INSTALLER. ' PIPE SIZING CHART FIXTURE UNITS PIPE SIZE GPM FLUSH VALVE OTHER 1/2' 1 — 1 3/4' 4 — 4 1' 9 — 13 1 1/4' 17 5 25 1 1/2' 25 8 42 2' 56 60 150 2 1/2' 98 225 370 o PEDERSEN TOYOTA NA�GN= /c9 'o FORT COLLINS, CO Job No: 20435 c `lo cn TM N. 16th Stmt e� /G N S Suite #200 �� •. � 2�- .;;�,� j PhoeniX AZ 85020 PH: 602.943.6608 WE: wwwMechDesigns.com FAX 602.943.6181