Loading...
HomeMy WebLinkAboutPlans - Utility Plan - 04/07/2025S M A S O N S T SITE CO L L E G E B L V D CREGER DR COLBOARD DR MA X G U I D E W A Y SHEET INDEX SHEET # C1.0 COVER SHEET 1 C1.1 NOTES SHEET 2 C1.2 NOTES SHEET 3 C2.0 INITIAL EROSION CONTROL 4 C2.1 INTERIM EROSION CONTROL 5 C2.2 FINAL EROSION CONTROL 6 C2.3 EROSION CONTROL DETAILS 7 C3.0 HORIZONTAL CONTROL PLAN 8 C4.0 GRADING PLAN 9 C5.0 UTILITY PLAN 10 C6.0 STORM PLAN AND PROFILE 11 C6.1 STORM PLAN AND PROFILE 12 C7.0 EXTENDED DETENTION BASIN PLAN 13 C7.1 EXTENDED DETENTION BASIN PLAN 14 C7.2 EXTENDED DETENTION BASIN PLAN 15 C8.0 CONSTRUCTION DETAILS 16 VICINITY MAP BENCHMARK BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING VOA SWITCHGRASS UTILITY PLANS LOT 2, CREGER PLAZA, THIRD REPLAT CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO APRIL 07, 2025 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g SCALE 1" = 200' 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS COVER SHEET C1.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 CONTACT LIST SURVEYOR ENGINEERING SERVICE COMPANY JUSTIN CONNOR, PLS 14190 E EVANS AVENUE AURORA, CO 80014 CIVIL ENGINEER SHOPWORKS ARCHITECTURE TED SWAN, PE 301 W. 45TH AVE DENVER, CO 80216 ARCHITECT SHOPWORKS ARCHITECTURE ED PARCELL, AIA 301 W. 45TH AVE DENVER, CO 80216 LANDSCAPE ARCHITECT RIPLEY DESIGN, INC RUSS LEE, PLA 419 CANYON AVENUE, SUITE 200 FORT COLLINS, CO 80521 OWNER/DEVELOPER VOLUNTEERS OF AMERICA DOUG SNYDER 2660 LARIMER ST DENVER, CO 80205 GENERAL NOTES 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CURRENT LARIMER COUNTY URBAN AREA STANDARDS. 2. ONSITE GRADING AND PAVING SHALL CONFORM TO THE GEOTECH REPORT. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD. 3. ALL EXISTING IMPROVEMENTS (INCLUDING PAVING, UTILITIES, ETC) AND ELEVATIONS SHALL BE VERIFIED PRIOR TO THE START OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD. 4. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL PROJECT PERMITS ASSOCIATED WITH CONSTRUCTION 5. CONTRACTOR SHALL MAINTAIN AT LEAST ONE PRINTED COPY OF THE APPROVED PLANS, SPECIFICATIONS AND STANDARDS ON THE JOB SITE AT ALL TIMES. 6. CONTRACTOR IS RESPONSIBLE FOR BEING AWARE OF, NOTIFYING, COORDINATING AND SCHEDULING ALL INSPECTIONS REQUIRED FOR FINAL APPROVALS AND PROJECT ACCEPTANCE. 7. PRIOR TO FINAL ACCEPTANCE, ALL DISTURBED PORTIONS OF ROADWAY ROW SHALL BE CLEANED UP AND RESTORED TO THEIR ORIGINAL CONDITION, SUBJECT TO CITY AND COUNTY APPROVAL. 8. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING ADEQUATE TRAFFIC CONTROL THROUGHOUT THE PROJECT, INCLUDING PROPER TRAFFIC CONTROL DEVICES AND/OR PERSONNEL AS REQUIRED. AFFIRMATION STATEMENT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design, revisions, and record conditions that I have noted on these plans. ____________________________________________ THEODORE SWAN, PE 43903 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS NOTES SHEET C1.1 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the Local Entity. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the Local Entity Engineer. Use of these plans after the expiration date will require a new review and approval process by the Local Entity prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the Local Entity, as beneficiary of said engineer’s work, for any errors and omissions contained in these plans, and approval of these plans by the Local Entity Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the Local Entity, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer, and water line construction, as well as power and other “dry” utility installations, shall conform to the Local Entity standards and specifications current at the date of approval of the plans by the Local Entity Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Engineer shall contact the Utility Notification Center of Colorado (UNCC) at 1- 800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the Local Entity prior to beginning construction. 10. The Developer shall coordinate and cooperate with the Local Entity, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The Local Entity shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the Local Entity, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The Local Entity shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the Local Entity failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the final drainage and erosion control study (name of the study and date) by (Engineering Firm) shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the Local Entity street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the Local Entity Engineering Inspector (Fort Collins - 221-6605) and the Local Entity Erosion Control Inspector (Fort Collins – 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the Local Entity Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the Local Entity reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the Local Entity’s default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the Local Entity Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the Local Entity inspector. The engineer or surveyor must certify in a letter to the Local Entity that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the Lo26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County FloodPlain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (Local Entity, County or State), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact Local Entity Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor; however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development’s local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the Local Entity Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the Local Entity. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. cal Entity before installation of base course or asphalt will be allowed on the streets. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the Local Entity Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Local Entity’s Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the Local Entity Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: Benchmarks—Local Entity survey. B.M.Number___________________,Elev.=_____________________, Description_______________________________________________. 41. All stationing is based on centerline/flowline (insert proper word) of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer’s expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Local Entity Construction Inspector before any cuts are made. Patching shall be done in accordance with the Local Entity Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Local Entity Engineer and/or the Local Entity Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all “T” intersections. 46. After acceptance by the Local Entity, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The Local Entity shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: (list). 48. Approved Variances are listed as follows: (Plan set must have a list of all applicable variances for the project).38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C D C O V E R & N O T E S . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS CONSTRUCTION NOTES SHEET C1.2 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_CD COVER & NOTES REF PLAN ----2 3 GRADING AND EROSION AND SEDIMENT CONTROL NOTES 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City of Loveland. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed asnecessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City of Loveland or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. To ensure that sediment does not move off of Individual lots one or more of the following sediment/erosion control BMPs shall be installed and maintained until the lots are sufficiently stabilized, as determined by the erosion control inspector, (Loveland GMA & city limits only). (a.) Below all gutter downspouts. (b.) Out to drainage swales. (c.) Along lot perimeter. (d.) Other locations, if needed. 16. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City of Loveland. 17. A Vehicle Tracking Control Pad shall be installed whenever it is necessary for construction equipment including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e., stone, dirt, etc., shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpile(s), staging area(s), construction material(s), concrete washout area(s) and/or building site(s). STREET IMPROVEMENT NOTES 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the Local Entity Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the Local Entity Engineer in Loveland. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the Local Entity Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the Local Entity Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the Local Entity Inspector and prior to installation of asphalt. Gutters that hold more than ¼ inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. “Proof roll” vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the Local Entity Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The Local Entity Engineer shall be notified at least 24 hours prior to the “proof roll.” All “proof rolls” shall be preformed in the presence of an Inspector. 10. Loveland only. 2-inch PVC conduit (with 3’ min. cover) shall be provided along arterial roadways with pull boxes at 500’ spacing or deflection points for future traffic signal interconnect. TRAFFIC SIGNING AND PAVEMENT MARKING NOTES 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per Local Entity Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines shall be latex paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the Local Entity Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Latex paint applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the Local Entity Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period, the Local Entity Engineer reserves the right to require additional signage and/or striping if the Local Entity Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. 16. Contractor is responsible for removing all anchors, posts, signs and/or delineators in Construction area. Contractor may keep the signs, or call the City Traffic Division to have them removed. 17. No “Reset” anchors, posts, signs, and/or delineators will be accepted. 18. All anchors, posts, signs, and/or delineators shall be new and be consistent with the LCUASS criteria. STORM DRAINAGE NOTES 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the final drainage and erosion control study (name of the study and date) by (Engineering Firm) shall be followed and implemented. 3. Prior to final inspection and acceptance by The City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 4. See City of Fort Collins Stormwater Criteria Manual – Appendix F Construction Control Measures Standard Notes and Standard Erosion Control Notes. WATERLINE NOTE 1. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS EEEEEE E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST ST ST ST ST ST ST ST ST ST ST ST SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) FIRE HYDRANT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN MATCH EXISTING GRADE AT PROPERTY LINE SSA LOC LOC LOC LOC LOC LOC LOC RS RS IPS VTC IPS EXISTING ELECTRIC AND LIGHTING TO BE REMOVED IN SITE BOUNDARIES EXISTING ASPHALT AND STRIPING TO BE REMOVED IN SITE BOUNDARIES EXISTING TREES TO BE REMOVED IN SITE BOUNDARIES EXISTING STAIRS TO BE REMOVED EXISTING STAIRS TO BE REMOVED EXISTING TREES TO BE REMOVED IN SITE BOUNDARIES EXISTING STORM LINE TO BE REMOVED AND REPLACED WITH PROPOSED LINE EXISTING STORM INLET TO BE REMOVED AND REPLACED WITH PROPOSED OUTLET STRUCTURE EXISTING STORM INLET TO BE REMOVED AND REPLACED WITH PROPOSED OUTLET STRUCTURE EXISTING ATTACHED WALKWAY TO BE REMOVED WHERE INDICATED EXISTING CURB ISLANDS TO BE REMOVED IN SITE BOUNDARIES FIBER OPTIC VAULT TO BE RELOCATED AS REQUIRED FOR NEW SIDEWALK EXISTING WALKWAY TO BE REMOVED WHERE INDICATED EXISTING TREES TO REMAIN EXISTING TREE TO REMAIN REMOVE EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN Pl o t t e d B y : Te d S w a n La y o u t : C2 . 0 I N I T I A L E R O S I O N C O N T R O L A N D D E M O P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 3 P M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - I n i t i a l . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS INITIAL EROSION CONTROL AND DEMO PLAN C2.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Erosion Control-Initial REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW SEDIMENT TRAP REINFORCED SILT FENCE SILT FENCE STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SOIL STOCKPILE CHECK DAM 5281 5280 5281 5280 ST ST SF SSA VTC IPS RS DD TSB SP LOC CD ST SFR NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 5038 50 3 8 5038 5038 503 9 503 9 50 3 9 50 3 9 5038 5038 5036 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 50 3 5 50 3 6 SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST ST ST ST WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) FIRE HYDRANT EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 2359 CU FT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC STORM PIPE (TYP) ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTEXISTING PIPE (TYP) ST 50 3 9 503 9 5039 EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 853 CU FT EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 653 CU FT EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) MATCH EXISTING GRADE AT PROPERTY LINE SSSS BUILDING EXCAVATION AREA CD CD DD 240 LF DD 85 LF DD 65 LF DD 35 LF LOC LOC LOC LOC LOC LOC LOC RS RS SSA VTC EXISTING STORM INLET TO BE REMOVED AND REPLACED WITH PROPOSED OUTLET STRUCTURE EXISTING STORM INLET TO BE REMOVED AND REPLACED WITH PROPOSED OUTLET STRUCTURE IPS 5037 5038 50 3 8 5038 5040 5038 5039 50415041 50 3 8 50 3 9 50 4 0 503 9 50 4 1 50 4 2 TSB TSB TSB CWA 4" S L O T T E D P V C P I P E Pl o t t e d B y : Te d S w a n La y o u t : C2 . 1 I N T E R I M E R O S I O N C O N T R O L P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 3 P M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - I n t e r i m . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS INTERIM EROSION CONTROL PLAN C2.1 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N S T -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Erosion Control-Interim REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SEEDING AND MULCHING CHECK DAM CONCRETE WASHOUT AREA 5281 5280 5281 5280 ST ST SSA VTC IPS RS DD TSB SM LOC CD NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING CWA 5038 50 3 8 5038 5038 503 9 503 9 50 3 9 50 3 9 5038 5038 5036 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 50 3 5 50 3 6 BBBBB B B B B B B B B SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST ST ST ST ST ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT FD UP VAN T WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) MAIN ENTRY 10' TREE LAWN FIRE HYDRANT LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC STORM PIPE (TYP) ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTEXISTING PIPE (TYP) ST 4' CONCRETE PAN 50 3 9 503 9 5039 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN COURTYARD (RE LANDSCAPE) EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) MATCH EXISTING GRADE AT PROPERTY LINE 5037 50 3 7 5038 50 3 8 5038 5039 50 3 8 50 3 9 5040 5038 5039 50415041 50 4 0 50 3 9 50 4 1 SSA VTC EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 2359 CU FT EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 853 CU FT EXTENDED DETENTION BASIN TO BE MODIFIED WITH 2" PACKED GRAVEL AT ORIFICE PLATE TO SERVE AS A TEMPORARY SEDIMENT BASIN DURING CONSTRUCTION VOLUME: 653 CU FT TSB TSB TSB SM SM SM SM SM CWA SM SM SM BUILDING FFE: 5039.50 BUILDING FFE: 5039.50 Pl o t t e d B y : Te d S w a n La y o u t : C2 . 2 F I N A L E R O S I O N C O N T R O L P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 3 P M Fi l e N a m e : 24 0 4 6 _ E r o s i o n C o n t r o l - F i n a l . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS FINAL EROSION CONTROL PLAN C2.2 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Erosion Control-Final REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' NOTES 1.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 2.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 3.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING SWMP PLAN LEGEND BOUNDARY LINE EXISTING CURB AND GUTTER EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED CURB AND GUTTER PROPOSED SIDEWALK PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR LIMITS OF CONSTRUCTION FLOW ARROW STABILIZED STAGING AREA VEHICLE TRACKING CONTROL INLET PROTECTION (SUMP) ROCK SOCKS DIVERSION DITCH TEMPORARY SEDIMENT BASIN SEEDING AND MULCHING CHECK DAM CONCRETE WASHOUT AREA 5281 5280 5281 5280 ST ST SSA VTC IPS RS DD TSB SM LOC CD CWA 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 12345 A B C D 12345 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ E r o s i o n C o n t r o l D e t a i l s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EROSION CONTROL DETAILS C2.3 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N ST -------- ---- -------- FO R T C O L L I N S , C O 80 5 2 5 Va l u e 24046_Erosion Control Details REF PLAN ----2 3 BBBBB B B B B B B B B FD UP AA 2 3 4 5 6 BB CC EE II KK DD JJ HH 1 GG A1A1 FF 4.1 VAN T SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) BUILDING GRID LINE J-5 N 1,438,414.18 E 3,117,833.40 MAIN ENTRY 6 ACCESSIBLE PARKING SIGN BIKE RACKS (TYP) (SEE LANDSCAPE FOR DETAILS) 10' TREE LAWN 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 EXISTING FIRE HYDRANT DETECTABLE WARNING (TRUNCATED DOMES) EXTENDED DETENTION BASIN (WATER QUALITY ONLY) EXTENDED DETENTION BASIN (WATER QUALITY ONLY) GRID LINE B-3 N 1,438,306.43 E 3,117,786.07 LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC 5 5 2 7 12 5 3 FDC 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 112" DOMESTIC WATER METER VAULT FIRE HYDRANT STOP SIGN COURTYARD (RE LANDSCAPE) ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB VAN ACCESSIBLE PARKING SIGN EV STALL EV STALL LOADING STALL 4' CONCRETE PAN ADA RAMP PER LARIMER COUNTY URBAN AREA DWG 1606 STANDARD DRIVEWAY APPROACH AND CROSSPAN PER LARIMER COUNTY URBAN AREA DWG 706.2 & 708 WATER ENTRY ROOM TRANSITION FROM 6" TO ZERO HEIGHT CURB 15' ACCESSIBLE PARKING STALL (TYP) DOG PARK TRASH PICKUP LOCATION TRASH ROOM INDOOR BIKE PARKING EXTENDED DETENTION BASIN (WATER QUALITY ONLY) EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN 26' EXISTING FIRE LANE EASEMENT 1 1 2 2 2 1 ELECTRIC TRANSFORMER PARKING STALLS TO BE LEASED BY NEIGHBORING PROPERTY Pl o t t e d B y : Te d S w a n La y o u t : C3 . 0 H O R I Z O N T A L C O N T R O L P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ S i t e P l a n . d w g SITE PLAN LEGEND PROPERTY LINE EXISTING CURB AND GUTTER EXISTING FIRE HYDRANT PROPOSED FENCE PROPOSED CURB AND GUTTER PROPOSED SPILL GUTTER PROPOSED SIDEWALK PROPOSED ASPHALT & SAWCUT PROPOSED FIRE HYDRANT PROPOSED TRANSFORMER PROPOSED SITE LIGHTING PROPOSED SIGNAGE PROPOSED ADA ACCESSIBLE ROUTE PROPOSED TREE LOCATION NUMBER OF PARKING STALLS T SIGHT TRIANGLE NOTES 1 - AASHTO SIGHT TRIANGLE - NO OBSTRUCTIONS OVER 24" PERMITTED WITHIN THE SIGHT TRIANGLE. BASED ON 4.04.2.10.1.01 2 - PEDESTRIAN SIGHT TRIANGLE - 10' LEG ON WALKWAY AND DRIVEWAY NO OBSTRUCTIONS OVER 30" THAT ARE WIDER THAN 18" ARE PERMITTED WITHIN THIS TRIANGLE # SITE PLAN NOTES 1.CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 2.ALL DIMENSIONS FROM FLOWLINE AND OUTSIDE BUILDING FACE UNLESS OTHERWISE NOTED 3.ALL ADA ACCESSIBLE RAMPS TO INCLUDE DETECTABLE WARNING PADS. 4.CONTRACTOR SHALL REMOVE AND REPLACE DAMAGED CURB, GUTTER, PAVING, AND LANDSCAPED AREAS OUTSIDE THE LIMITS OF SITE AND RESTORE BACK TO ITS ORIGINAL CONDITION. 5.PAVEMENT THICKNESS PER GEOTECH REPORT. 6.ALL ENTRANCES ARE PRIVATE UNLESS OTHERWISE NOTED. 7.ADDITIONAL ROADWAY IMPROVEMENTS MAY BE REQUIRED PENDING TIS UPDATES. 8.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING N 40'0 SCALE: 1" = 20' 20' 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS HORIZONTAL CONTROL PLAN C3.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Site Plan REF PLAN ----2 3 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 R3-5R 30"x36" 5038 50 3 8 5038 5038 503 9 503 9 50 3 9 50 3 9 5038 5038 5036 50 4 0 50 3 8 50 3 9 50 4 0 50 3 8 50 3 9 50 3 5 50 3 6 BBBBB B B B B B B B B SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT FD UP VAN T WWW WWW WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) MAIN ENTRY 10' TREE LAWN FIRE HYDRANT DETECTABLE WARNING (TRUNCATED DOMES) EXTENDED DETENTION BASIN (WATER QUALITY ONLY) SEE EDB PLANS FOR GRADING AND WALL ELEVATIONS LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC ACCESSIBLE PARKING STALL (TYP) STCO-A04 Storm Cleanout STMH-A02 2' NYLOPLAST BASIN STINLET-B02 MODIFIED TYPE C OUTLET STRUCTURE STINLET-A03 TYPE 16 COMBO INLET STINLET-B01 MODIFIED TYPE C OUTLET STRUCTURE STINLET-D01 MODIFIED TYPE C OUTLET STRUCTURE STORM PIPE (TYP) ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTEXISTING PIPE (TYP) ST ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB ZERO HEIGHT CURB 4' CONCRETE PAN TRANSITION FROM 6" TO ZERO HEIGHT CURB 15' 50 3 9 503 9 5039 503 8 . 1 2 503 8 . 2 4 503 7 . 6 4 503 8 . 4 8 503 9 . 2 0 503 7 . 8 5 503 8 . 5 0 503 8 . 6 1 503 9 . 0 5 503 9 . 3 1 503 9 . 1 9 503 8 . 4 3 503 8 . 8 4 503 8 . 7 6 503 8 . 8 9 M E 503 8 . 4 8 503 7 . 7 9 503 7 . 4 0 503 7 . 4 4 503 7 . 8 3 503 7 . 8 7 503 8 . 2 0 503 7 . 4 1 503 7 . 8 8 503 7 . 3 0 503 8 . 0 3 503 8 . 9 8 503 8 . 9 7 5038.93 503 9 . 2 8 503 9 . 2 6 503 8 . 6 5 503 8 . 6 5 EXTENDED DETENTION BASIN (WATER QUALITY ONLY) SEE EDB PLANS FOR GRADING AND WALL ELEVATIONS EXTENDED DETENTION BASIN (WATER QUALITY ONLY) SEE EDB PLANS FOR GRADING AND WALL ELEVATIONS 6' ATTACHED CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 6' CONCRETE SIDEWALK PER LARIMER COUNTY STANDARD DWG 1602 ADA RAMP PER LARIMER COUNTY URBAN AREA DWG 1606 STANDARD DRIVEWAY APPROACH AND CROSSPAN PER LARIMER COUNTY URBAN AREA DWG 706.2 & 708 503 8 . 2 2 ME 503 8 . 2 5 ME 503 8 . 7 4 ME 503 9 . 0 7 ME 503 9 . 1 5 ME 503 8 . 9 9 M E EXISTING DRIVEWAY APPROACH, SIDEWALK AND CROSSPAN TO REMAIN BUILDING FFE: 5039.50 BUILDING FFE: 5039.50 503 8 . 9 3 503 8 . 5 8 COURTYARD (RE LANDSCAPE) 503 8 . 0 6 503 7 . 8 3 503 7 . 5 1 503 8 . 2 1 503 7 . 9 7 503 8 . 1 4 503 8 . 4 0 503 8 . 4 3 503 8 . 7 2 503 8 . 1 5 503 8 . 1 7 503 8 . 9 1 503 8 . 8 1 503 8 . 1 4 503 8 . 1 5 503 7 . 5 7 EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN EXISTING CURB AND GUTTER TO REMAIN 503 8 . 3 0 503 8 . 2 2 503 8 . 9 9 M E 503 8 . 9 4 M E 0. 5 % 0. 5 % 0. 5 % 0. 5 % ACCESSIBLE PARKING SIGN 0.7%0.7% LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) 503 7 . 8 7 503 8 . 7 6 503 8 . 4 7 503 8 . 1 6 503 7 . 5 1 503 7 . 4 2 503 7 . 4 5 503 7 . 7 2 503 7 . 8 9 503 7 . 9 8 503 8 . 0 2 503 8 . 1 1 1.4% 503 8 . 1 4 503 8 . 2 3 1.4% 503 8 . 2 5 503 8 . 3 4 1.5% 503 8 . 3 0 503 8 . 3 9 1.5% 503 8 . 5 7 503 8 . 6 6 1.5% 503 8 . 6 9 503 8 . 7 8 1.5% 503 8 . 9 0 503 8 . 9 5 0.8% 503 8 . 9 6 M E 2.0% 2.0% 0.5% 503 8 . 8 1 503 8 . 8 6 1.0%1.0% MATCH EXISTING GRADE AT PROPERTY LINE TRASH PICKUP LOCATION 1.4% 1.4% 1.4% 4.0% 503 7 . 7 9 1.6% 503 7 . 9 3 503 7 . 9 8 503 7 . 8 6 2.3% 1.1 % 0.5 % 1.3% 1. 4 % 1. 4 % 1. 4 % 1. 4 % 1. 5 % 503 8 . 3 2 503 8 . 5 9 503 9 . 2 1 503 8 . 8 3 503 9 . 0 5 503 9 . 5 0 1. 4 % 503 9 . 0 5 503 9 . 1 0 503 9 . 5 0 5.4% 4.6% 503 9 . 5 0 4.9% 2.6% 503 9 . 3 8 503 9 . 4 8 503 8 . 8 3 503 9 . 5 0 503 9 . 5 0 503 8 . 8 3 503 9 . 4 7 503 9 . 4 1 503 9 . 5 0 503 9 . 5 0 503 9 . 5 0 503 8 . 8 3 503 8 . 8 3 503 8 . 5 5 503 9 . 1 1 503 9 . 4 9 503 9 . 5 0 503 9 . 5 0 503 9 . 5 0 FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION FOUNDATION CURB CONDITION 1.6% 1.3% 4" S L O T T E D P V C P I P E U N D E R D R A I N 1.6% 503 8 . 8 6 503 9 . 5 0 Pl o t t e d B y : Te d S w a n La y o u t : C4 . 0 G R A D I N G P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ G r a d i n g P l a n . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS GRADING PLAN C4.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Grading Plan REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' GRADING PLAN LEGEND PROPERTY BOUNDARY EXISTING WATER LINE EXISTING FIRE HYDRANT EXISTING SEWER LINE EXISTING SEWER MANHOLE EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING FIBER LINE EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED FIRE HYDRANT PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED SLOPE PROPOSED CONCRETE SIDEWALK PROPOSED ASPHALT ROAD PROPOSED ADA ACCESSIBLE ROUTE W FO G E 5281 5280 5281 5280 SS SS ST ST 5887.19 0.5% NOTES 1.ALL ENTRANCES ARE PRIVATE UNLESS OTHERWISE NOTED. 2.SIDEWALKS AND LANDINGS SHALL SLOPE 1.5% TOWARDS ROADS, DRIVE LANES UNLESS NOTED OTHERWISE. 3.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE PROPOSED ELEVATIONS SHOWN ON THE GRADING PLAN. THE ENGINEER WILL NOT BE LIABLE FOR ANY COSTS ASSOCIATED WITH CHANGES TO THE DESIGN WITHOUT PROPER NOTIFICATION. 4.THE MAXIMUM SLOPE WITHIN ROW IS 4:1, THE MAXIMUM SLOPE FOR PROPERTY OUTSIDE OF THE ROW IS 3:1. 5.THE SLOPE AWAY FROM THE BUILDING WITHIN LANDSCAPED AREAS SHALL BE NO LESS THAN 5% FOR THE FIRST 10' 6.THE RESULTANT GRADE IN ANY DIRECTION WITHIN ACCESSIBLE PARKING AREAS SHALL NOT EXCEED TWO PERCENT. 7.THE MAXIMUM CROSS SLOPE IN AN ACCESSIBLE PATH SHALL NOT EXCEED TWO PERCENT. THE MAXIMUM LONGITUDINAL SLOPE IN AN ACCESSIBLE PATH SHALL NOT EXCEED FIVE PERCENT. 8.EXISTING UTILITIES STRUCTURES TO BE ADJUSTED AS NECESSARY TO MEET PROPOSED GRADE. 9.ALL STORM SEWER IS PRIVATE AND WILL BE MAINTAINED BY OWNER UNLESS OTHERWISE NOTED. 10.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM).ALL ACCESSIBLE UNITS CAN BE REACHED FROM THE MAIN ENTRY ALONG AN ACCESSIBLE ROUTE WITHIN THE BUILDING 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 BBBBB B B B B B B B B SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 STORM MH ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT FD UP AA 2 3 4 5 6 BB CC EE II KK DD JJ HH 1 GG A1A1 FF 4.1 VAN T WWW WWW SS SS WW SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) BUILDING EXTENDED DETENTION BASIN (WATER QUALITY ONLY) EXTENDED DETENTION BASIN (WATER QUALITY ONLY) LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC EXISTING FIRE HYDRANT FIRE HYDRANT WATER ENTRY ROOM EXTENDED DETENTION BASIN (WATER QUALITY ONLY) 9+90 10+00 10+62 SSSS SSCO-A02 DOUBLE CLEANOUT CONNECT TO BUILDING SEWER (RE: PLUMBING) N: 1438409.14 E: 3117752.98 SSTEE - A01 10"X6" TEE N: 1438409.24 E: 3117701.07 51.9 LF ~ 6" SDR-35 PVC SEWER ST STSTST ST STMH-A02 2' NYLOPLAST BASIN STCO-A04 Storm Cleanout Storm Cleanout STINLET-B02 MODIFIED TYPE C OUTLET STRUCTURE Storm Cleanout STINLET-A03 TYPE 16 COMBO INLET STINLET-B01 MODIFIED TYPE C OUTLET STRUCTURE TRANSITION TO SOLID PVC PIPE STINLET-D01 MODIFIED TYPE C OUTLET STRUCTURE 12" PVC Pipe 12 " P V C P i p e 8" PVC Pipe 18" RCP15" EXISTING RCP 6" EXISTING PVC Pipe 12" EXISTING PVC P I P E 4" S L O T T E D P V C P I P E 4" P V C P i p e 4" P V C P I P E 9+90 10+00 10+72 REPLACE EXISTING STORM LINE CONNECT TO EXISTING STORM LINE CONNECT TO EXISTING STORM LINE EX I S T I N G 8 " W A T E R L I N E EX I S T I N G 1 0 " S E W E R L I N E EX I S T I N G 1 8 " S T O R M L I N E 8"X6" TAPPING SLEEVE W/ 6" TAPPING VALVE N 1,438,321.80 E 3,117,690.56 8"X 112 " TAPPING SLEEVE W/ CORP STOP N 1,438,314.30 E 3,117,690.56 112" DOMESTIC WATER METER VAULT N 1,438,314.72 E 3,117,739.58 49 LF~ 112" TYPE K COPPER 13 LF~ 112" TYPE K COPPER 63 LF~ 6" DIP17.50' WATERLINE LOWERING WITH (4) VERTICAL 45 DEG BENDS AND T.B. 15.00' WATERLINE LOWERING WITH (4) VERTICAL 45 DEG BENDS AND T.B. EXISTING FIBER AND ELECTRIC CROSSINGS EXISTING FIBER AND ELECTRIC CROSSINGS EXISTING STORM AND SANITARY CROSSINGS EXISTING STORM CROSSING EXISTING STORM AND SANITARY CROSSINGS EXISTING FIBER AND ELECTRIC CROSSINGS FDC W/ KNOX BOX ELECTRIC TRANSFORMER SSA PROFILE Vertical Exaggeration = 5X 5025 5030 5035 5040 5045 5025 5030 5035 5040 5045 EG = 5 0 3 8 . 9 FG = 5 0 3 8 . 9 3 10+00 EG = 5 0 3 7 . 2 FG = 5 0 3 7 . 2 1 10+50 FIRE LINE PROFILE Vertical Exaggeration = 5X 5025 5030 5035 5040 5045 5025 5030 5035 5040 5045 EX. GROUND @ ℄ PROPOSED GROUND @ ℄ CONNECT TO BLDG SEWER LINE AT DOUBLE CLEANOUT (RE: PLUMBING) STA. 10+51.91 INV=5032.62 CONNECT TO EXISTING SANITARY MAIN WITH 12"X6" TEE. CONTRACTOR TO VERIFY ELEVATION PRIOR TO CONSTRUCTION STA. 10+00.00 INV =5032.11 51.9 LF~ 6" SDR-35 PVC SEWER @ 1.00 % EXISTING STORM EXISTING FIBER EXISTING ELECTRIC AND PHONE LINES EXISTING FIBER EG = 5 0 3 8 . 1 FG = 5 0 3 8 . 1 3 10+00 EG = 5 0 3 8 . 0 FG = 5 0 3 8 . 0 4 10+50 BUILDING FFE: 5039.50 10"X6" TAPPING SLEEVE W/ 6" TAPPING VALVE VERIFY ELEVATIONS PRIOR TO CONSTRUCTION STA. 10+00.00 TOP=5030.50 CONNECT TO BLDG WATER (RE: PLUMBING) STA. 10+62.70 TOP=5032.26 BUILDING FFE=5039.50 PROPOSED GROUND @ ℄ EX. GROUND @ ℄ 62 LF~6" D I P WATERLINE DEFLECTION 2 DEG MAX. STA. 10+21.36 TOP=5030.30 EXISTING ELECTRIC AND PHONE LINESEXISTING ELECTRIC AND PHONE LINES EXISTING ELECTRIC AND PHONE LINES EXISTING SEWER LINE WATERLINE LOWERING EXISTING FIBER LINE Pl o t t e d B y : Te d S w a n La y o u t : C5 . 0 U T I L I T Y P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ U t i l i t y P l a n . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS UTILITY PLAN C5.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Utility Plan REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' UTILITY PLAN LEGEND EXISTING WATER LINE EXISTING FIRE HYDRANT EXISTING SEWER LINE EXISTING SEWER MANHOLE EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING FIBER LINE EXISTING GAS LINE EXISTING ELECTRIC LINE PROPOSED WATER LINE PROPOSED FIRE HYDRANT PROPOSED SEWER LINE PROPOSED SEWER MANHOLE PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED FIBER LINE PROPOSED GAS LINE PROPOSED ELECTRIC LINE W FO G E W FO SS G E SS SS ST ST SS SCALE 1"=20' (HOR.) 1"=4' (VERT) SCALE 1"=20' (HOR.) 1"=4' (VERT) FIRE FLOW DATA BLOCK TOTAL FIRE FLOW REQS ARE 1500 GPM MIN @ 20 PSI RESIDUAL PRESSURE (75% REDUCTION FOR FULLY SPRINKLED BUILDING) THIS FLOW MUST BE PROVIDED FROM A MINIMUM OF 1 FIRE HYDRANT EACH FIRE HYDRANT MUST SUPPLY 1500 GPM MIN @ 20 PSI RESIDUAL PRESSURE AT THE HYDRANT OUTLET TO BE ACCEPTABLE CODE USED FOR ANALYSIS: 2021 IFC OCCUPANCY GROUP: A3, R-2 CONSTRUCTION TYPE: V-A (RESIDENTIAL) FIRE AREA: 46,450 SF NOTES 1.THE CONTRACTOR IS TO VERIFY THE ELEVATION OF ALL EXISTING UTILITIES WHERE NEW WORK WILL CONNECT AND NOTIFY THE ENGINEER IF THERE ARE ANY DISCREPANCIES. 2.MANHOLES ARE CONTROLLED AT CENTER OF MANHOLE. 3.ALL WATER SERVICES DOWNSTREAM OF THE METER SHALL BE PRIVATE. 4.ALL SANITARY SERVICES SHALL BE PRIVATE. 5.ALL PROPOSED STORM SEWERS SHOWN ARE TO BE PRIVATE UNLESS OTHERWISE NOTED 6.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM). 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 SS SS SS SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W SANITARY MH RIM=5039.00 10" PVC INV S=5031.85 10" PVC INV N=5031.70 STORM INLET TOG=5036.90 12" PVC INV N=5035.10 12" PVC INV W=5035.10 ST ST ST ST ST ST ST ST ST ST ST ST STORM MH RIM=5038.87 15" RCP INV E=5035.02 18" RCP INV S=5034.17 18" RCP INV NE=5034.17 ST STORM MH RIM=5038.85 18" RCP INV S=5034.45 12" RCP INV W=5034.65 18" RCP INV N=5034.45 W UTILITY CABINET TRANSFORMER GENERATOR UTILITY VAULT UTILITY VAULT UTILITY VAULT FD UP 2 3 4 5 6 BB CC EE II KK DD JJ HH 1 GG FF 4.1 T WWW WWW SS SS SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) BUILDING LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 CREGER 3RD REPLAT (PLAT - REC. NO. 20190044858) OWNER: MASON PLACE LLLP EXISTING FIRE HYDRANT WATER ENTRY ROOM EXTENDED DETENTION BASIN (WATER QUALITY ONLY) SSSS SSCO-A02 DOUBLE CLEANOUT SSTEE - A01 10"X6" TEE 6" SDR-35 PVC SEWER ST STMH-A02 2' NYLOPLAST BASIN N: 1438444.84 E: 3117753.77 STCO-A04 Storm Cleanout N: 1438442.65 E: 3117860.95 Storm Cleanout N: 1438361.35 E: 3117866.71 RIM=5038.75' INV =5036.51' (S) STINLET-A03 TYPE 16 COMBO INLET N: 1438449.56 E: 3117784.55 STINLET-D01 MODIFIED TYPE C OUTLET STRUCTURE N: 1438429.23 E: 3117743.80 31.1 LF ~ 12 " P V C P i p e 7.4 LF ~ 12" PVC Pipe 76.7 LF ~ 8" PVC Pipe 12" EXISTING PVC P I P E 112" DOMESTIC WATER METER VAULT 9+ 9 0 10 + 0 0 11+00 11+25 9+90 10+00 10+42 102.0 LF ~ 4" SLOTTED PVC PIPE @ 0.50% (SEE DETAIL THIS SHEET) STORM LINE A STORM LINE D STA PROFILE Vertical Exaggeration = 5X 5025 5030 5035 5040 5045 5050 5055 5025 5030 5035 5040 5045 5050 5055 EG = 5 0 3 7 . 5 FG = 5 0 3 7 . 4 5 10+00 EG = 5 0 3 7 . 8 FG = 5 0 3 7 . 8 3 10+50 EG = 5 0 3 8 . 1 FG = 5 0 3 8 . 1 3 11+00 ST C O - A 0 4 St o r m C l e a n o u t RI M = 5 0 3 8 . 8 7 ' IN V . O U T = 5 0 3 6 . 6 1 ( W ) 76.7 LF~ 8" PVC Pipe @ 0.50% ST I N L E T - A 0 3 TY P E 1 6 C O M B O I N L E T TF I = 5 0 3 8 . 3 5 ' IN V . I N = 5 0 3 6 . 2 2 ( E ) IN V . O U T = 5 0 3 5 . 8 9 ( W ) 31.1 LF~ 12" PVC Pipe @ 0.50% ST M H - A 0 2 2' N Y L O P L A S T BA S I N RI M = 5 0 3 9 . 2 5 ' IN V . I N = 5 0 3 5 . 7 3 ( E ) IN V . O U T = 5 0 3 5 . 7 3 ( S W ) 7.4 LF~ 12" PVC Pipe @ 0.49% STD PROFILE Vertical Exaggeration = 5X 5025 5030 5035 5040 5045 5050 5055 5025 5030 5035 5040 5045 5050 5055 EG = 5 0 3 8 . 9 FG = 5 0 3 8 . 8 7 10+00 EG = FG = 10+50 ST ST ST ST ST I N L E T - D 0 1 MO D I F I E D T Y P E C OU T L E T S T R U C T U R E RI M = 5 0 3 7 . 6 5 ' IN V . O U T = 5 0 3 5 . 1 0 ( W ) 32.0 LF~ 12" EXISTING PVC PIPE @ 0.25% CONNECT TO EXISTING STORM LINE. CONTRACTOR TO VERIFY ELEVATIONS PRIOR TO CONSTRUCTION STA. 9+99.94 INV=5035.70 CONCRETE FOREBAY Pl o t t e d B y : Te d S w a n La y o u t : C6 . 0 S T O R M P L A N & P R O F I L E - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ S t o r m P l a n a n d P r o f i l e s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS STORM PLAN & PROFILE C6.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Storm Plan and Profiles REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' UTILITY PLAN LEGEND EXISTING WATER LINE EXISTING FIRE HYDRANT EXISTING SEWER LINE EXISTING SEWER MANHOLE EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING FIBER LINE EXISTING GAS LINE EXISTING ELECTRIC LINE PROPOSED WATER LINE PROPOSED FIRE HYDRANT PROPOSED SEWER LINE PROPOSED SEWER MANHOLE PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED FIBER LINE PROPOSED GAS LINE PROPOSED ELECTRIC LINE TFI W FO G E W FO SS G E SS SS ST ST SS SCALE 1"=20' (HOR.) 1"=4' (VERT) NOTES 1.THE CONTRACTOR IS TO VERIFY THE ELEVATION OF ALL EXISTING UTILITIES WHERE NEW WORK WILL CONNECT AND NOTIFY THE ENGINEER IF THERE ARE ANY DISCREPANCIES. 2.MANHOLES ARE CONTROLLED AT CENTER OF MANHOLE. 3.ALL WATER SERVICES DOWNSTREAM OF THE METER SHALL BE PRIVATE. 4.ALL SANITARY SERVICES SHALL BE PRIVATE. 5.ALL PROPOSED STORM SEWERS SHOWN ARE TO BE PRIVATE UNLESS OTHERWISE NOTED 6.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM). 1' MIN COVER 1' DEPTH 4" SLOTTED PVC UNDERDRAIN MIRAFI WRAPPED DRAIN GRAVEL 1' WIDTH SLOTTED UNDERDRAIN DETAIL NTS TOP FACE OF INLET 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 BBBBB B B B B B B B B SS SS SS SS SS SS SS SS SS SS E EE E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOW W W W W W W W W W W SANITARY MH RIM=5038.02 8" PVC INV S=5032.52 10" PVC INV N=5032.32 STORM MH RIM=5037.76 15" RCP INV E=5033.76 18" RCP INV S=5032.76 28"X45" ELLIPSE RCP INV W=5033.66 18" RCP INV N=5032.66 ST ST ST ST ST ST ST ST ST ST STSTST ST STORM INLET TOG=5035.93 15" RCP INV W=5034.45 TOG=5040.38 6" PVC INV W=5038.15 ST ST ST AA BB CC A1A1 VAN WWW WWW WW EXTENDED DETENTION BASIN (WATER QUALITY ONLY) EXTENDED DETENTION BASIN (WATER QUALITY ONLY) LOT 2 MORELAND SUBDIVISION (PLAT - REC. NO. 91030712) OWNER: D AND M AUTOMOTIVE LOT 1 PLAT OF MASON STREET PUD (PLAT - REC. NO. 520208) OWNER: RCA MASON LLC FIRE HYDRANT WATER ENTRY ROOM ST STSTST STINLET-B02 MODIFIED TYPE C OUTLET STRUCTURE N: 1438187.98 E: 3117893.63 Storm Cleanout N: 1438234.06 E: 3117867.30 RIM=5037.90' INV =5035.87' (SE) STINLET-B01 MODIFIED TYPE C OUTLET STRUCTURE N: 1438187.60 E: 3117741.48 TRANSITION TO SOLID PVC PIPE 152.1 LF ~ 18" RCP 15" EXISTING RCP 6" EXISTING PVC Pipe 102.0 LF ~ 4" SLOTTED PVC PIPE @ 0.50% 4 0 . 7 L F ~ 4 " P V C P i p e @ 0 . 5 0 % 25.2 LF ~ 4" PVC PIPE @ 0.50% REPLACE EXISTING STORM LINE CONNECT TO EXISTING STORM LINE CONNECT TO EXISTING STORM LINE EX I S T I N G 8 " W A T E R L I N E EX I S T I N G 1 0 " S E W E R L I N E EX I S T I N G 1 8 " S T O R M L I N E 112" DOMESTIC WATER METER VAULT 15.00' WATERLINE LOWERING WITH (4) VERTICAL 45 DEG BENDS AND T.B. 9+90 10+00 11+00 12+00 12+09 STORM LINE B STB PROFILE Vertical Exaggeration = 5X 5025 5030 5035 5040 5045 5050 5055 5025 5030 5035 5040 5045 5050 5055 EG = 5 0 3 7 . 8 FG = 5 0 3 7 . 7 6 10+00 EG = 5 0 3 6 . 3 FG = 5 0 3 6 . 2 7 10+50 EG = 5 0 3 6 . 5 FG = 5 0 3 6 . 4 9 11+00 EG = 5 0 3 7 . 1 FG = 5 0 3 7 . 1 1 11+50 EG = 5 0 3 7 . 6 FG = 5 0 3 7 . 6 0 12+00 ST ST ST ST ST ST ST ST152.1 LF~ 18" RCP @ 0.50% ST I N L E T - B 0 2 MO D I F I E D T Y P E C OU T L E T S T R U C T U R E RI M = 5 0 3 7 . 7 5 ' IN V . I N = 5 0 3 6 . 8 7 ( E ) IN V . O U T = 5 0 3 5 . 1 0 ( W ) 66.9 LF~ 6" EXISTING PVC Pipe @ 1.92% 30.4 LF~ 15" EXISTING RCP @ 1.23% ST I N L E T - B 0 1 MO D I F I E D T Y P E C OU T L E T S T R U C T U R E RI M = 5 0 3 6 . 0 8 ' IN V . I N = 5 0 3 4 . 3 4 ( E ) IN V . O U T = 5 0 3 4 . 1 4 ( W ) CONNECT TO EXISTING STORM LINE. CONTRACTOR TO VERIFY ELEVATIONS PRIOR TO CONSTRUCTION CONNECT TO EXISTING STORM LINE. CONTRACTOR TO VERIFY ELEVATIONS PRIOR TO CONSTRUCTION Pl o t t e d B y : Te d S w a n La y o u t : C6 . 1 S T O R M P L A N & P R O F I L E - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ S t o r m P l a n a n d P r o f i l e s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS STORM PLAN & PROFILE C6.1 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_Storm Plan and Profiles REF PLAN ----2 3 N 40'0 SCALE: 1" = 20' 20' SCALE 1"=20' (HOR.) 1"=4' (VERT) NOTES 1.THE CONTRACTOR IS TO VERIFY THE ELEVATION OF ALL EXISTING UTILITIES WHERE NEW WORK WILL CONNECT AND NOTIFY THE ENGINEER IF THERE ARE ANY DISCREPANCIES. 2.MANHOLES ARE CONTROLLED AT CENTER OF MANHOLE. 3.ALL WATER SERVICES DOWNSTREAM OF THE METER SHALL BE PRIVATE. 4.ALL SANITARY SERVICES SHALL BE PRIVATE. 5.ALL PROPOSED STORM SEWERS SHOWN ARE TO BE PRIVATE UNLESS OTHERWISE NOTED 6.BENCHMARK: CITY OF FORT COLLINS BM 'VIRATA”- 2” ALUMINUM CAP STAMPED “CITY OF FORT COLLINS BENCHMARK VRATA” FOUND AT THE NORTHWEST CORNER OF COLLEGE AVE., AND HORSETOOTH ROAD ON THE BACK OF WALK AT THE EAST END OF THE PARAPET WALL OF THE BRIDGE OVER CANAL NO. 2. ELEVATION: 5034.31 FEET (NAVD 1988 DATUM). 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 UTILITY PLAN LEGEND EXISTING WATER LINE EXISTING FIRE HYDRANT EXISTING SEWER LINE EXISTING SEWER MANHOLE EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING FIBER LINE EXISTING GAS LINE EXISTING ELECTRIC LINE PROPOSED WATER LINE PROPOSED FIRE HYDRANT PROPOSED SEWER LINE PROPOSED SEWER MANHOLE PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED FIBER LINE PROPOSED GAS LINE PROPOSED ELECTRIC LINE TFI W FO G E W FO SS G E SS SS ST ST SS TOP FACE OF INLET E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOST ST ST ST ST ST ST ST SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) 10' TREE LAWN STMH-A02 2' NYLOPLAST BASIN STINLET-D01 MODIFIED TYPE C OUTLET STRUCTURE ST ST ST ST ST ST 503 5 . 6 0 G B W EXTENDED DETENTION BASIN (EDB-A) (WATER QUALITY ONLY) 503 8 . 9 9 M E 503 8 . 9 0 503 8 . 9 5 0.8%0.5% 503 8 . 8 1 503 8 . 8 6 1.0% 0.5% 4.1 % 503 5 . 6 0 G B W 503 5 . 6 0 G B W 503 5 . 6 0 G B W 503 8 . 8 0 G T W 503 9 . 0 0 G T W 503 9 . 0 0 G T W 503 9 . 5 0 503 9 . 4 8 503 9 . 5 0 503 8 . 8 0 G T W 503 5 . 6 0 G B W 503 9 . 0 0 G T W MICROPOOL503 5 . 3 0 503 5 . 3 0 3. 6 % 503 8 . 8 0 G T W 4.4 % 5.0 % 503 5 . 2 0 503 5 . 2 0 CONCRETE FOREBAY W/ 1.5" SLOT DRAIN SOIL RIPRAP AT SPILLWAY (SEE DETAIL THIS SHEET) EMERGENCY OVERFLOW SPILLWAY ELEV 5038.80 WSEL 5038.86 LANDSCAPE WALL (3' MAX HT) A A MODIFIED TYPE C INLET OUTLET STRUCTURE WITH CLOSE MESH INLET GRATE ELEV 5037.65 CONNECT TO EXISTING OUTLET PIPE 12" MICROPOOL DEPTH 2.5% WQCV WQ ORIFICE PLATE AND TRASH RACK (SEE DETAIL D) WATER QUALITY VOLUME SURFACE ELEV 5037.28 100 YR SURFACE ELEV 5037.85 DETAIL B - WQ ORIFICE PLATE 3/8" WQ ORIFICE INV: 5035.25 3/8" DIA STAINLESS STEEL ANCHOR BOLTS TO ADHERE ORIFICE PLATE ON INTERIOR OF INLET BOX (TYP) 12" WIDE 5 YEAR ORIFICE PLATE MOUNTED ON INTERIOR OF INLET BOX NO. 93 JOHNSON VEE WIRE STAINLESS STEEL WELL SCREEN (OR EQUIVALENT) C8X18.75 AMERICAN STANDARD STRUCTURAL STEEL CHANNEL. FORMED INTO CONCRETE BOTTOM AND SIDES OF INLET BOX OPENING. TRASH RACK ATTACHED BY INTERMITTENT WELDING 6" INLET BOX OPENING 10" WIDE TRASH RACK DETAIL C - SOIL RIPRAP TYPE M RIPRAP (MIN THICKNESS 24") 6" SOIL COVER GTW GBW ELEV 5035.30 AT TOP EDGE OF MICROPOOL ELEV 5035.10 GROUT GAP BETWEEN OUTLET STRUCTURE AND LANDSCAPE WALL 3/8" WQ ORIFICE INV: 5037.25 BLOCK OUT TO BE INSTALLED IN LANDSCAPE WALL FOR EXISTING PIPE PENETRATION 6" FOREBAY DEPTH DETAIL D - CONCRETE FOREBAY BLOCK OUT TO BE INSTALLED IN LANDSCAPE WALL FOR PROPOSED PIPE PENETRATION 6" CONCRETE DEPTH FOREBAY 6" CONCRETE DEPTH 1.5" DRAIN SLOT AT FRONT OF FOREBAY ELEV 5035.60 ELEV 5035.50 EMERGENCY OVERFLOW W/ BURIED RIPRAP ELEV 5038.80 Pl o t t e d B y : Te d S w a n La y o u t : C7 . 0 E X T E N D E D D E T E N T I O N B A S I N P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION BASIN PLAN C7.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 N 10'0 SCALE: 1" = 5' 5' POND PLAN LEGEND EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED GRADE GRADE AT THE TOP OF WALL GRADE AT THE BOTTOM OF WALL 5281 5280 5281 5280 ST ST POND PLAN NOTES 1.LOOSE MATERIAL SHALL BE STORED AWAY FROM RAIN GARDEN 2.THE CONTRACTOR SHALL PREVENT ANY SEDIMENT, DEBRIS AND OTHER MATERIAL FROM ENTERING THE RAIN GARDEN DURING AND AFTER SYSTEM INSTALLATION. 3.PLACEMENT OF THE WEARING COURSE SHALL BE PERFORMED AFTER FINE GRADING AND LANDSCAPING IN ADJACENT AREAS IS COMPLETE. IF THE WEARING COURSE BECOMES CLOGGED DUE TO CONSTRUCTION ACTIVITIES, CLEAN THE SURFACE WITH A VACUUM MACHINE TO RESTORE THE INFILTRATION RATE AFTER CONSTRUCTION IS COMPLETE. 5887.19 0.5% EXTENDED DETENTION BASIN (EDB-A) SECTION A-A DETAIL E - WELL SCREEN SECTION 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 5038 5038 5036 ST ST ST ST ST ST ST ST ST ST ST STINLET-B02 MODIFIED TYPE C OUTLET STRUCTURE STORM PIPE (TYP) STSTSTSTSTSTSTSTSTSTEXISTING PIPE (TYP) ZERO HEIGHT CURB 503 8 . 2 4 503 7 . 8 3 503 7 . 8 7 503 8 . 2 0 503 7 . 8 8 503 7 . 3 0 503 8 . 0 3 503 7 . 5 1 503 7 . 9 7 503 8 . 1 4 0.7% LANDSCAPE WALL (3' MAX HT) LANDSCAPE WALL (3' MAX HT) 1.1 % 1. 5 % 503 8 . 3 2 EXTENDED DETENTION BASIN (EDB-B) (WATER QUALITY ONLY) MICROPOOL CONCRETE FOREBAY W/ 1.5" SLOT DRAIN EMERGENCY OVERFLOW SPILLWAY ELEV 5037.87 WSEL 5038.26 503 6 . 6 5 503 6 . 4 2 503 6 . 6 6 G B W 503 5 . 2 2 G B W 503 5 . 9 1 G B W 503 6 . 6 9 G B W 503 7 . 4 0 G T W 503 9 . 1 7 G T W 503 9 . 0 6 G T W 503 8 . 4 0 G T W 503 8 . 5 3 G T W 503 6 . 6 4 G B W 503 5 . 3 0 503 5 . 4 6 503 5 . 8 2 503 6 . 0 6 503 6 . 2 4 3.1 % 3.0% 3.0% 503 8 . 3 9 G T W 503 5 . 6 6 3.0 % 3. 0 % 3.0% 503 6 . 1 9 G B W 503 5 . 3 7 G B W 3.0 % A A CURB AND GUTTER WITH CONCRETE RETAINING WALL CURB AND GUTTER WITH CONCRETE RETAINING WALL CURB AND GUTTER WITH CONCRETE RETAINING WALL Pl o t t e d B y : Te d S w a n La y o u t : C7 . 1 E X T E N D E D D E T E N T I O N B A S I N P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION BASIN PLAN C7.1 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 N 10'0 SCALE: 1" = 5' 5' POND PLAN LEGEND EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED GRADE GRADE AT THE TOP OF WALL GRADE AT THE BOTTOM OF WALL 5281 5280 5281 5280 ST ST POND PLAN NOTES 1.LOOSE MATERIAL SHALL BE STORED AWAY FROM RAIN GARDEN 2.THE CONTRACTOR SHALL PREVENT ANY SEDIMENT, DEBRIS AND OTHER MATERIAL FROM ENTERING THE RAIN GARDEN DURING AND AFTER SYSTEM INSTALLATION. 3.PLACEMENT OF THE WEARING COURSE SHALL BE PERFORMED AFTER FINE GRADING AND LANDSCAPING IN ADJACENT AREAS IS COMPLETE. IF THE WEARING COURSE BECOMES CLOGGED DUE TO CONSTRUCTION ACTIVITIES, CLEAN THE SURFACE WITH A VACUUM MACHINE TO RESTORE THE INFILTRATION RATE AFTER CONSTRUCTION IS COMPLETE. 5887.19 0.5% EXTENDED DETENTION BASIN (EDB-B) SECTION A-A DETAIL E - WELL SCREEN SECTION MODIFIED TYPE C INLET OUTLET STRUCTURE WITH CLOSE MESH INLET GRATE ELEV 5037.65 CONNECT TO EXISTING PIPE UPSTREAM AND INSTALL NEW OUTLET PIPE 12" MICROPOOL DEPTH 2.5% WQCV WQ ORIFICE PLATE AND TRASH RACK (SEE DETAIL D) WATER QUALITY VOLUME SURFACE ELEV 5036.91 100 YR SURFACE ELEV 5037.75 DETAIL B - WQ ORIFICE PLATE 3/8" WQ ORIFICE INV: 5035.25 3/8" DIA STAINLESS STEEL ANCHOR BOLTS TO ADHERE ORIFICE PLATE ON INTERIOR OF INLET BOX (TYP) 12" WIDE 5 YEAR ORIFICE PLATE MOUNTED ON INTERIOR OF INLET BOX NO. 93 JOHNSON VEE WIRE STAINLESS STEEL WELL SCREEN (OR EQUIVALENT) C8X18.75 AMERICAN STANDARD STRUCTURAL STEEL CHANNEL. FORMED INTO CONCRETE BOTTOM AND SIDES OF INLET BOX OPENING. TRASH RACK ATTACHED BY INTERMITTENT WELDING 6" INLET BOX OPENING 10" WIDE TRASH RACK GTW GBW ELEV 5035.30 AT TOP EDGE OF MICROPOOL ELEV 5035.10 RAISE BACK AND SIDES OF OUTLET STRUCTURE TO MATCH TOP OF LANDSCAPE WALL ELEVATION 6" FOREBAY DEPTH DETAIL D - CONCRETE FOREBAY 6" CONCRETE DEPTH FOREBAY 6" CONCRETE DEPTH 1.5" DRAIN SLOT AT FRONT OF FOREBAY ELEV 5036.65 ELEV 5036.42 ELEV 5037.30 2' GUTTER 3/8" WQ ORIFICE INV: 5035.93 3/8" WQ ORIFICE INV: 5036.61 CURB AND GUTTER WITH CONCRETE RETAINING WALL 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 50 3 5 50 3 6 EEE E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST WWWWWWW STINLET-B01 MODIFIED TYPE C OUTLET STRUCTURE ST ST ST ST ST ST ST ST STSTSTSTST 503 7 . 6 4 503 7 . 4 1 LANDSCAPE WALL (3' MAX HT) 503 6 . 4 0 503 6 . 3 8 503 6 . 1 0 503 5 . 6 8 503 5 . 2 3 503 4 . 9 4 503 4 . 8 0 503 6 . 5 2 G B W 503 4 . 7 3 G B W 503 5 . 2 9 G B W 503 5 . 8 5 G B W 503 5 . 6 1 G B W 503 7 . 6 5 G T W 503 8 . 1 4 G T W 503 7 . 0 0 G T W 503 7 . 8 7 G T W EXTENDED DETENTION BASIN (EDB-C) (WATER QUALITY ONLY) 5.0% 5.0% 6.5% 3.0% 3.1% 3.2 % 3.0 % 5.0 % EMERGENCY OVERFLOW SPILLWAY ELEV 5037.00 WSEL 5037.15 503 7 . 3 3 G T W 503 7 . 5 3 M E SO U T H M A S O N S T R E E T (M A J O R A R T E R I A L 30 ' R I G H T - O F - W A Y ) A A MODIFIED TYPE C INLET OUTLET STRUCTURE WITH CLOSE MESH INLET GRATE ELEV 5036.08 CONNECT TO EXISTING PIPE UPSTREAM AND INSTALL NEW OUTLET PIPE 12" MICROPOOL DEPTH 2.5% WQCV WQ ORIFICE PLATE AND TRASH RACK (SEE DETAIL D) WATER QUALITY VOLUME SURFACE ELEV 5035.79 100 YR SURFACE ELEV 5036.25 DETAIL B - WQ ORIFICE PLATE 3/8" WQ ORIFICE INV: 5034.75 3/8" DIA STAINLESS STEEL ANCHOR BOLTS TO ADHERE ORIFICE PLATE ON INTERIOR OF INLET BOX (TYP) 12" WIDE 5 YEAR ORIFICE PLATE MOUNTED ON INTERIOR OF INLET BOX NO. 93 JOHNSON VEE WIRE STAINLESS STEEL WELL SCREEN (OR EQUIVALENT) C8X18.75 AMERICAN STANDARD STRUCTURAL STEEL CHANNEL. FORMED INTO CONCRETE BOTTOM AND SIDES OF INLET BOX OPENING. TRASH RACK ATTACHED BY INTERMITTENT WELDING 6" INLET BOX OPENING 10" WIDE TRASH RACK GTW GBW ELEV 5034.80 AT TOP EDGE OF MICROPOOL ELEV 5034.20 RAISE BACK AND SIDES OF OUTLET STRUCTURE TO MATCH TOP OF LANDSCAPE WALL ELEVATION 6" FOREBAY DEPTH DETAIL C - CONCRETE FOREBAY 6" CONCRETE DEPTH FOREBAY 6" CONCRETE DEPTH 1.5" DRAIN SLOT AT FRONT OF FOREBAY ELEV 5036.40 ELEV 5036.38 Pl o t t e d B y : Te d S w a n La y o u t : C7 . 2 E X T E N D E D D E T E N T I O N B A S I N P L A N - C I T Y Pr i n t e d O n : 4/ 7 / 2 0 2 5 2 : 4 4 P M Fi l e N a m e : 24 0 4 6 _ E D B P l a n s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS EXTENDED DETENTION BASIN PLAN C7.2 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G -------- ---- -------- 24046_EDB Plans REF PLAN ----2 3 N 10'0 SCALE: 1" = 5' 5' POND PLAN LEGEND EXISTING STORM LINE EXISTING STORM MANHOLE EXISTING STORM INLET EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR PROPOSED STORM LINE PROPOSED STORM MANHOLE PROPOSED STORM INLET PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED SPOT ELEVATION PROPOSED GRADE GRADE AT THE TOP OF WALL GRADE AT THE BOTTOM OF WALL 5281 5280 5281 5280 ST ST POND PLAN NOTES 1.LOOSE MATERIAL SHALL BE STORED AWAY FROM RAIN GARDEN 2.THE CONTRACTOR SHALL PREVENT ANY SEDIMENT, DEBRIS AND OTHER MATERIAL FROM ENTERING THE RAIN GARDEN DURING AND AFTER SYSTEM INSTALLATION. 3.PLACEMENT OF THE WEARING COURSE SHALL BE PERFORMED AFTER FINE GRADING AND LANDSCAPING IN ADJACENT AREAS IS COMPLETE. IF THE WEARING COURSE BECOMES CLOGGED DUE TO CONSTRUCTION ACTIVITIES, CLEAN THE SURFACE WITH A VACUUM MACHINE TO RESTORE THE INFILTRATION RATE AFTER CONSTRUCTION IS COMPLETE. 5887.19 0.5% EXTENDED DETENTION BASIN (EDB-C) SECTION A-A DETAIL D - WELL SCREEN SECTION ELEV 5037.41 2' GUTTER 3/8" WQ ORIFICE INV: 5035.08 3/8" WQ ORIFICE INV: 5035.42 38 0 0 S O U T H M A S O N S T FO R T C O L L I N S , C O 8 0 5 2 5 CURB AND GUTTER WITH CONCRETE RETAINING WALL 12345 A B C D 12345 fi l e p a t h : C: \ U s e r s \ t e d \ D C \ A C C D o c s \ S h o p w o r k s A r c h i t e c t u r e \ 2 4 0 4 6 V O A F o r t C o l l i n s M a s o n S t - \ P r o j e c t F i l e s \ C i v i l \ S h e e t s \ C o n s t r u c t i o n D o c u m e n t s \ 2 4 0 4 6 _ C o n s t r u c t i o n D e t a i l s . d w g 1 PROJECT #: DRAWN: REV: SCALE: NO. SHEET TITLE: REVIEWED: DATE: FILE: 12345 A B C D A B C D 12345 TS CONSTRUCTION DOCUMENTS CONSTRUCTION DETAILS C8.0 TS 24046 03/16/2024 SW I T C H G R A S S C R O S S I N G 38 0 0 S O U T H M A S O N S T -------- ---- -------- FO R T C O L L I N S , C O 8 0 5 2 5 24046_Construction Details REF PLAN ----2 3