HomeMy WebLinkAboutPlans - Electrical Plan - 03/28/2025Feeder Schedule 3000/W 2000/W 1600/W 1200/W 1000/W 800/W 760/W 600/W 500/W 400/W 380/W 300/W 250/W 225/W 200/W 175/W 150/W 125/W 110/W 100/W 90/W 80/W 70/W 60/W 50/W 40/W 30/W 20/W This table indicates minimum conductor size for feeders of the ampacity indicated where #/W indicates the #-Ampacity and W-numbers of wire, #S/W indicates no ground. All conductors shall be Copper unless noted otherwise. * Conductor Ampacities shall be based on table 310.15(B)(16) 60 degree column up to 100 Amps and 75 degree column above 100 Amps unless otherwise permitted by NEC. Ampacity rating shall be selected in accordance NEC 110.14 (C). The master electrician shall be responsible for ensuring that no feeders or branch circuits are installed in a manner or sized in such a way as to violate the NEC. Service Ground Table 150G 200G 300G 500G 800G >800G Service Ground Conductors sized Per NEC Table 250.66 Equipment Ground Conductors sized Per NEC Table 250.122 All conductors shall be Copper unless noted otherwise. The service ground chart indicates the minimum Service Ground Conductor based on #G where # is the ampacity from the chart above, and the equipment ground chart indicates the minimum equipment grounding conductor size #EG where # is the rating/ setting of the overcurrent device protecting the conductors and equipment. Where discrepancies occur between the Feeder Schedule Schedule and the Grounding Tables, the larger conductor shall be used unless otherwise permitted by the NEC. The installation shall meet all NEC 250 grounding and bonding requirements including 250.4 Path for Fault Current. Provide complete raceway systems metallically joined, connected, and fittings as required for electrical continuity per NEC 300.10 8[W-500kcmil, 400kcmil, 3-1/2"C] 6[W-400kcmil, 250kcmil, 3"C] 5[W-400kcmil, 4/0G, 3"C] 4[W-350kcmil, 3/0G, 3"C] 3[W-400kcmil, 2/0G, 3"C] 3[W-300kcmil, 1/0G, 3"C] 2[W-500kcmil, 1/0G, 3-1/2"C] 2[W-350kcmil, #1G, 3"C] 2[W-250kcmil, #2G, 3"C] 2[W-3/0, #3G, 2"C] W-500kcmil, #3G, 3-1/2"C W-350kcmil, #4G, 3"C W-250kcmil, #4G, 3"C W-4/0, #4G, 2-1/2"C W-3/0, #6G, 2"C W-2/0, #6G, 2"C W-1/0, #6G, 2"C W#1, #6G, 1-1/2"C W#2, #6G, 1-1/4"C *60 Degree W#1, #6G, 1-1/2"C W#2, #8G, 1-1/4"C W#3, #8G, 1-1/4"C W#4, #8G, 1-1/4"C W#4, #10G, 1-1/4"C W#6, #10G, 1"C W#8, #10G, 1" C W#10, #10G, 3/4"C W#12, #12G, 3/4"C #6 #4 #2 1/0 2/0 3/0 Equipment Ground Table 20EG 60EG 100EG 200-1200A per Above 1600EG 2000EG *75 Degree W#3, #6G, 1-1/4"C W#3, #8G, 1-1/4"C W#4, #8G, 1-1/4"C W#4, #8G, 1-1/4"C W#6, #10G, 1"C W#8, #10G, 1" C W#8, #10G, 1" C W#10, #10G, 3/4"C W#12, #12G, 3/4"C #12 #10 #8 4/0 250kcmil Feeder Schedule - Aluminum 3000S/W 2000/W 1600/W 1200/W 1000/W 800/W 750/W 600/W 500/W 400/W 350/W 300/W 250/W 225/W 200/W 175/W 150/W 125/W 110/W 100/W 90/W 80/W 70/W 60/W 50/W 40/W 30/W 20/W This table indicates minimum conductor size for feeders of the ampacity indicated where #/W indicates the #-Ampacity and W-numbers of wire, #S/W indicates no ground. All conductors shall be Aluminum unless noted otherwise. * Conductor Ampacities shall be based on table 310.15(B)(16) 60 degree column up to 100 Amps and 75 degree column above 100 Amps unless otherwise permitted by NEC. Ampacity rating shall be selected in accordance NEC 110.14 (C). The master electrician shall be responsible for ensuring that no feeders or branch circuits are installed in a manner or sized in such a way as to violate the NEC. Service Ground Table 150G 200G 300G 500G 1000G >1000G Service Ground Conductors sized Per NEC Table 250.66 Equipment Ground Conductors sized Per NEC Table 250.122 All conductors shall be Aluminum unless noted otherwise. The service ground chart indicates the minimum Service Ground Conductor based on #G where # is the ampacity from the chart above, and the equipment ground chart indicates the minimum equipment grounding conductor size #EG where # is the rating/ setting of the overcurrent device protecting the conductors and equipment. Where discrepancies occur between the Feeder Schedule Schedule and the Grounding Tables, the larger conductor shall be used unless otherwise permitted by the NEC. The installation shall meet all NEC 250 grounding and bonding requirements including 250.4 Path for Fault Current. Provide complete raceway systems metallically joined, connected, and fittings as required for electrical continuity per NEC 300.10 14[W-350kcmil, 3"C] 7[W-500kcmil, 400kcmil G, 3-1/2"C] 8[W-250kcmil, 350kcmilG, 3"C] 4[W-500kcmil, 250kcmil G, 3-1/2"C] 4[W-350kcmil, 4/0G, 3"C] 3[W-400kcmil, 3/0G, 3"C] 3[W-350kcmil, 2/0G, 3"C] 2[W-500kcmil, 2/0G, 3-1/2"C] 2[W-350kcmil, 1/0G, 3"C] 2[W-250kcmil, #1G, 3"C] 2[W-4/0, #1G, 2-1/2"C] W-500kcmil, #2G, 3-1/2"C W-350kcmil, #2G, 3"C W-300kcmil, #2G, 3"C W-250kcmil, #4G, 2-1/2"C W-4/0, #4G, 2"C W-3/0, #4G, 2"C W-2/0, #4G, 2"C W-1/0, #4G, 2"C *60 Degree W-1/0, #6G, 2"C W-1/0, #6G, 2"C W#1, #6G, 1-1/2"C W#2, #6G, 1-1/4"C W#2, #8G, 1-1/4"C W#4, #8G, 1-1/4"C W#6, #8G, 1" C W#8, #8G, 3/4"C W#10, #10G, 3/4"C #4 #2 1/0 3/0 4/0 250 Equipment Ground Table 20EG 60EG 100EG 200-1200A per Above 1600EG 2000EG *75 Degree W#1, #6G, 1-1/2"C W#2, #6G, 1-1/4"C W#2, #6G, 1-1/4"C W#3, #6G, 1-1/4"C W#4, #8G, 1-1/4"C W#6, #8G, 1" C W#8, #8G, 1" C W#10, #8G, 3/4"C W#12, #10G, 3/4"C #10 #8 #6 350kcmil 400kcmil ALUMINUM FEEDER BID ALTERNATE: PROVIDE SEPARATE PRICE FOR ALUMINUM MAIN FEEDERS WHERE INDICATED ON THE ONE LINE DIAGRAM ONLY. ANY USE OF ALUMINUM CONDUCTORS SHALL BE APPROVED BY THE OWNER. 4000/W 11[W-500kcmil, 500kcmil, 3-1/2"C]4000S/W 13[W-500kcmil, 800kcmil G, 3-1/2"C] 1 ONE LINE DIAGRAM NTSSCALE: ONE LINE DIAGRAM GENERAL NOTES: 1.E.C. TO FIELD VERIFY EXISTING CONDITIONS 2.ALL EQUIPMENT IS NEW. 3.ALL EXTERIOR EQUIPMENT TO BE WEATHERPROOF 4.FIELD VERIFY INSTALLATION REQUIREMENTS WITH UTILITY PRIOR TO ANY ROUGH-IN. 5.THE E.C. SHALL PROVIDE LABELING OF ALL DISCONNECTING MEANS IN ACCORDANCE WITH NEC 110.22: 5.a.PROVIDE LABEL ON EACH DISCONNECTING MEANS PER NEC 110.22(A) 5.b.SERVICE EQUIPMENT SHALL BE LABELED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AND DATE PER NEC 110.24(A). 5.c.WHERE ANY SERIES RATED COMBINATION SYSTEMS ARE UTILIZED, PROVIDE LABEL ON EQUIPMENT CLOSURE INDICATING THE SERIES RATED SYSTEM COMPONENTS INCLUDING FUSE AND BREAKER TYPES AND RATINGS IN ACCORDANCE WITH NEC 110.22(B) AND 110.22(C): CAUTION -- SERIES COMBINATION SYSTEM RATED ____ AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. ONE LINE DIAGRAM KEYED NOTES: 1.PROVIDE CONCRETE PAD FOR UTILITY COMPANY PAD MOUNT TRANSFORMER. REFER TO UTILITY COMPANY STANDARD FOR INSTALLATION AND USE FOR REQUIREMENTS. 2.PROVIDE GROUNDING ELECTRODE CONDUCTORS, GROUNDING ELECTRODES FOR GROUND RODS, WATER SERVICE, BUILDING STEEL, AND CONCRETE ENCASED GROUNDING ELECTRODES, AND ALL CONNECTIONS AS REQUIRED PER NEC 250 PART III. 3.PROVIDE A TYPE I or TYPE II SURGE PROTECTION DEVICE (SPD) TRANSIENT VOLTAGE SURGE SUPPRESSOR (TVSS) IN ACCORDANCE WITH NEC 230.67(A). THE SPD MAY BE AN INTEGRAL PART OF THE SERVICE EQUIPMENT OR LOCATED IMMEDIATELY ADJACENT THERETO, OR, PER NEC EXCEPTION, AT EACH NEXT LEVEL DISTRIBUTION EQUIPMENT DOWNSTREAM TOWARDS THE LOAD. 4.PROTECT FIRE PUMP NORMAL AND EMERGENCY FEEDERS PER NEC 695.6(A)(2). FEEDER SHALL BE INSTALLED UNDERGROUND AND/OR OUTSIDE OF BUILDING OR ENCASE IN CONCRETE WHERE ROUTED THROUGH BUILDING # LEVEL 1 PAD MOUNTED UTILITY TRANSFORMER 208/120V, 3-PHASE, 4W 4000S/4 T PANEL H1 400A/3P 2-400A/3P SPACE 400/4 1 METER UTILITYM MAIN SWITCHBOARD 'MSB', 4000A 208/120V, 3PHASE,4W, 85KAIC, NEMA 3R>800G N G 800A/3P R1-1 UTILITY METER MAX. AVAILABLE FAULT CURRENT = (FUSE LET-THRU) 7,000 A R1-1 METER STACK NEMA 3R 65 k AIC M M M M M M M M M 800/4 ALUMINUM 1 SPD 3 BOND AND GROUND PER NEC 250 ·BUILDING STEEL and COLD WATER PIPE, 3/0Cu ·UFER, #4Cu ·GROUND ROD, #6Cu 2 M M UNIT PANEL TYPICAL 125/3 (TYPICAL FOR EACH UNIT) 42 k AIC 125A/2P WITH HOT SEQUENCE UTILITY METER PER UTILITY, TYPICAL M LEVEL 2 MMMM M M M M PANEL EV 400A/3P 400/4 2 PANEL H4 400A/3P 400/4 4 LEVEL 3 LEVEL 4 ROOF 70/4 ELEV 1 100A/3P 100A/3P 3 H SHUNT TRIP 70FRN S SECONDARY CONNECTION CABINET 208/120V, 3-PHASE, 4W, 4000A 2000A/3P PROVIDE ARC FLASH REDUCTION REQUIRED PER 2023 NEC 2000A/3P (2) 2" CONDUIT TO FUTURE SOLAR 6 M M M M M 800A/3P R1-2 UTILITY METER MAX. AVAILABLE FAULT CURRENT = (FUSE LET-THRU) 7,000 A R1-1 METER STACK NEMA 3R 65 k AIC M M M M M M M M M 800/4 M MM MMMM M M M M M M M M M 800A/3P R1-2 UTILITY METER MAX. AVAILABLE FAULT CURRENT = (FUSE LET-THRU) 7,000 A R1-1 METER STACK NEMA 3R 65 k AIC M M M M M M M M M 800/4 M MM MMMM M M M M M M M M MM 400S/4 FP ALUMINUM >800G MSB 5 4000S/4 COPPER ALL WORK TO BE INSTALLED INSIDE FIRE PUMP ROOM PER NEC 695 300/4 FIRE PUMP GENERAL NOTES: 1.FIRE PUMP SIZE AND REQUIREMENTS SHALL BE DETERMINED BY THE PROVIDER. 2.SEPARATE SERVICE FOR FIRE PUMP MUST BE APPROVED BY CITY OF FORT COLLINS LIGHT AND POWER AND BUILDING DEPARTMENT PRIOR TO ANY WORK. 3.FIRE PUMP INSTALLATION SHALL COMPLY WITH ALL NEC REQUIREMENTS, RE: NEC ARTICLE 695. 4.PROVIDE PLACARD ON EACH SERVICE DISCONNECT LOCATION DENOTING ALL OTHER SERVICES, FEEDERS, AND BRANCH CIRCUITS SUPPLYING THE BUILDING IN ACCORDANCE WITH NEC 230.2(E). 5.PROVIDE SEPARATE PRICE FOR ALL ELECTRICAL WORK ASSOCIATED WITH THE FIRE PUMP SYSTEM. 208/120V, 3PH, 4W, 42kAIC FIRE PUMP CONTROL CABINET JOCKEY PUMP CONTROL CABINET FIRE PUMP 50HP(VERIFY) VERIFY FLA VERIFY LRA JOCKEY PUMP 2HP(VERIFY) VERIFY FLA >800G 4 4 N G 1200A Class L 1200A/3P METER UTILITY M BOND AND GROUND PER NEC 250 AMERICAN MIDWEST POWER COMBINATION C.T. & DISCONNECT 1200A 208/120V, 3PH, 4W, 85kAIC PROJECT NAME:302 CONIFER BUILDING DEVELOPMENT REVIEW - LEGAL DESCRIPTION: LOT 13, BLK 5,REPLAT NO. 1 OF EVERGREEN PARK BDR240019 - 302 CONIFER STREET 2024 Santulan Architecturec ISSUE DATE: 11/15/2024 ISSUE DATE BDR SUBMITTAL 1 2024.11.15 BDR SUBMITTAL 2 2025.02.14 BDR SUBMITTAL 3 2025.03.28 Front Range Electrical Engineering 3333 S. Wadsworth Blvd. Suite D210, Lakewood, CO 80227 Fax: 720.638.8870 Ph: 303.985.0548 ONE LINE DIAGRAM SHEET E1.0