HomeMy WebLinkAboutPlans - Electrical Plan - 10/24/2024M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 T F 800/3 800A 800/3 800A 4000S4 1 2 150F3 PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800/3 800A M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 150/2 150F3 800F4 800F4 800F4 800F4 800F4 800F4 3 3 3 3 3 3 3 3 PANEL "LPH1" 2000S4 T F 2000/3 M PANEL "LPH2A"T F 30 / 3 80 0 / 3 40 0 / 3 10 0 / 3 60 / 3 60 / 3 15 0 / 3 15 0 / 3 15 0 / 3 15 0 / 3 15 0 / 3 15 0 / 3 40 0 / 3 40 0 / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 XX X / 3 M XX/3 400F4 2000F4 SPDM PANEL "TENANT" 200F4 T F 800/3 PANEL "LPL1B" 40 0 / 3 400F4 PANEL "LPL1A" 40 0 / 3 400F4 30 / 3 M XX/3 30 / 3 M XX/3 30 / 3 60 / 2 60 / 2 60 / 2 60 / 2 M 100/3 6 M 60/3 6 M 60/3 6 60F260F260F260F2 100F3 60F3 60F3 PANEL "LPH2B" PANEL "LPL2A" T F PANEL "LPL2B" PANEL "LPH3A"T F PANEL "LPH3B" PANEL "LPL3A" T F PANEL "LPL3B" PANEL "LPH4A"T F PANEL "LPH4B" PANEL "LPL4A" T F PANEL "LPL4B" PANEL "LPH5A"T F PANEL "LPH5B" PANEL "LPL5A" T F PANEL "LPL5B" M XX/3 M XX/3 M XX/3 M XX/3 M XX/3 M XX/3 PANEL "EM1" 20 0 / 3 200F4 PANEL "ELEV" 60F4 200F4 200/3 200F4 PANEL "EM2" PANEL "EM3" PANEL "EM4" PANEL "EM5" 60F4 60F4 100F4 100F4 150F3 150F3 150F3 150F3 150F3 150F3 400F3 400F3 N G 120/208V, 3PH, 4W PAD MOUNTED TRANSFORMER "MSB-METERS" 4000A, 120/208V, 3PH, 4W, NEMA 3R, 100kAIC TYPICAL UNIT PANEL (QTY 25) 3 E8.00 DWELLING ONE-LINE KEY NOTES: 1."MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC OR EQUIVALENT (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. # 1 1 TO UTILITY PRIMARY TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) 1 TYPICAL UNIT PANEL (QTY 25) TOTAL 259 UNITS PLUS METER FOR COFFEE SHOP "MSB" 2000A, 480/277V, 3PH, 4W, 65KAIC 480/277V, 3PH, 4W, UTILITY TRANSFORMER 3 E8.00 MECH EQUIP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 (TYP) T2A 4 E8.00 GFI ONE-LINE KEY NOTES: 1.WHERE FLOOR MOUNTED, PROVIDE A 5-1/2" THICK CONCRETE PAD WITH 3/4" CHAMFER ON EDGES NOT ABUTTING A WALL. # 1 TO UTILITY PRIMARY GROUND LEVEL 2ND LEVEL T1A 12345678910 CONTINUE PENDING FINAL EV AND MECH EQUIPMENT COUNT 3 MECH EQUIPMECH EQUIPLEVEL 2 EV CHARGER LEVEL 2 EV CHARGER LEVEL 2 EV CHARGER LEVEL 2 EV CHARGER FREIGHT ELEVATOR ELEVATOR 1 ELEVATOR 2 3RD LEVEL 4TH LEVEL 5TH LEVEL ROOF 2ND LEVEL 3RD LEVEL 4TH LEVEL 5TH LEVEL ROOF T2B 4 E8.00 T3A 4 E8.00 T3B 4 E8.00 T4A 4 E8.00 T4B 4 E8.00 T5A 4 E8.00 T5B 4 E8.00 MECH EQUIP MECH EQUIP MECH EQUIP MECH EQUIP MECH EQUIP MECH EQUIP PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVISIONS PROVIDE DISCONNECT WITH METER 1 ATS 200A, 4P XXKW/XXKVA, GENERATOR 208/120V, 3PH, 4W, NEMA 3R GROUND LEVEL 3 E8.00 MAIN BONDING JUMPER BY MANUFACTURER GR O U N D E D (N E U T R A L ) NEUTRAL BUS SERVICE EQUIPMENT GROUND BUS IF METALIC CONDUIT IS USED, BOND CONDUIT TO GROUND BAR OR TO GROUNDING ELECTRODE CONDUCTOR; MATCH SIZE OF GROUNDING ELECTRODE CONDUCTOR (TYP FOR METAL CONDUIT) BOND CONDUIT TO GROUNDING ELECTRODE OR TO GROUNDING ELECTRODE CONDUCTOR; MATCH SIZE OF GROUNDING ELECTRODE CONDUCTOR (TYP FOR METAL CONDUIT) IF PRESENT PROVIDE GEC FROM EQUIPMENT GROUND BUS TO THE FOLLOWING: 1. METAL UNDERGROUND WATER PIPE. 2. METALLIC IN GROUND SUPPORT STRUCTURES. 3. CONCRETE ENCASED ELECTRODE, 20 FT OF REINFORCED BARS, OR 20 FT OF BARE #4 AWG CU CONDUCTOR OR LARGER. 4. GROUND RING, CONSISTING OF 20 FT OF DIRECT BURIED BARE #2 AWG CU CONDUCTOR OR LARGER. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD TO TELECOMMUNICATION GROUND BAR, OR LISTED INTERSYSTEM BONDING TERMINATION AT TELECOM SERVICE ENTRANCE SERVICE CONDUIT CONTINUED TO SERVICE TRANSFORMER GROUNDING SYSTEM TESTING: THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. GEC = GROUNDING ELECTRODE CONDUCTOR SIZE PER NEC TABLE 250.66 AND 250.122 ENCLOSURE PH A S E PH A S E PH A S E GR O U N D "DELTA PRIMARY" PRIMARY EQUIPMENT GROUNDING CONDUCTOR PER PLAN GROUNDING ELECTRODE CONDUCTOR; CONNECT TO BUILDING STEEL UNLESS OTHERWISE NOTED BONDING JUMPER SIZED TO MATCH SECONDARY GROUNDING CONDUCTOR SECONDARY SYSTEM BONDING JUMPER PER PLANGR O U N D PH A S E (W H E R E IN D I C A T E D ) NE U T R A L PH A S E PH A S E "WYE SECONDARY" XO TERMINAL 5235 Ronald Reagan Blvd., Suite 200 Johnstown, CO 80534 970.800.3300 PROJECT *NOT FOR CONSTRUCTION CLIENT SEAL / DISCLAIMER PROJECT #: SHEET# 24014 DATE: TITLE PROSPECT PLAZA 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 CONSULTANTS 3/ 1 4 / 2 0 2 5 1 0 : 4 1 : 4 2 A M Au t o d e s k D o c s : / / 2 4 0 0 2 T e t r a d - F o r t C o l l i n s - P r o s p e c t P l a z a / H B S0 2 - P r o s p e c t P l a z a _ M E P _ R 2 3 . r v t Pr o s p e c t P l a z a NU M B E R E8.00 ONE-LINE DIAGRAM 10/24/24 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 800 800S3 3 2 1/2"(3)300 KCM N/A 800 800S3 3 3"(3)400 KCM N/A 800 800F3 3 2 1/2"(3)300 KCM (1)#1/0 800 800F3 3 3"(3)400 KCM (1)#3/0 AL 700 700S3 2 3"(3)500 KCM N/A 700 700S3 3 3"(3)350 KCM N/A 700 700F3 2 3"(3)500 KCM (1)#1/0 700 700F3 3 3"(3)350 KCM (1)#3/0 AL 600 600S3 2 2 1/2"(3)350 KCM N/A 600 600S3 2 3 1/2"(3)500 KCM N/A 600 600F3 2 2 1/2"(3)350 KCM (1)#1 600 600F3 2 3 1/2"(3)500 KCM (1)#2/0 AL 500 500S3 2 2 1/2"(3)250 KCM N/A 500 500S3 2 2 1/2"(3)350 KCM N/A 500 500F3 2 2 1/2"(3)250 KCM (1)#2 500 500F3 2 2 1/2"(3)350 KCM (1)#1/0 AL 450 450S3 2 2"(3)#4/0 N/A 450 450S3 2 2 1/2"(3)300 KCM N/A 450 450F3 2 2"(3)#4/0 (1)#2 450 450F3 2 2 1/2"(3)300 KCM (1)#1/0 AL 400 400S3 2 2"(3)#3/0 N/A 400 400S3 2 2 1/2"(3)250 KCM N/A 400 400F3 2 2"(3)#3/0 (1)#3 400 400F3 2 2 1/2"(3)250 KCM (1)#1 AL 350 350S3 1 3"(3)500 KCM N/A 350 350S3 2 2 1/2"(3)#4/0 N/A 350 350F3 1 3"(3)500 KCM (1)#3 350 350F3 2 2 1/2"(3)#4/0 (1)#1 AL 300 300S3 1 2 1/2"(3)350 KCM N/A 300 300S3 1 3 1/2"(3)500 KCM N/A 300 300F3 1 2 1/2"(3)350 KCM (1)#4 300 300F3 1 3 1/2"(3)500 KCM (1)#2 AL 250 250S3 1 2 1/2"(3)250 KCM N/A 250 250S3 1 2 1/2"(3)350 KCM N/A 250 250F3 1 2 1/2"(3)250 KCM (1)#4 250 250F3 1 2 1/2"(3)350 KCM (1)#2 AL 225 225S3 1 2 1/2"(3)#4/0 N/A 225 225S3 1 2"(3)300 KCM N/A 225 225F3 1 2 1/2"(3)#4/0 (1)#4 225 225F3 1 2"(3)300 KCM (1)#2 AL 200 200S3 1 2"(3)#3/0 N/A 200 200S3 1 2"(3)250 KCM N/A 200 200F3 1 2"(3)#3/0 (1)#6 200 200F3 1 2"(3)250 KCM (1)#4 AL 175 175S3 1 2"(3)#2/0 N/A 175 175S3 1 2"(3)#4/0 N/A 175 175F3 1 2"(3)#2/0 (1)#6 175 175F3 1 2"(3)#4/0 (1)#4 AL 150 150S3 1 1 1/2"(3)#1/0 N/A 150 150S3 1 1 1/2"(3)#3/0 N/A 150 150F3 1 1 1/2"(3)#1/0 (1)#6 150 150F3 1 1 1/2"(3)#3/0 (1)#4 AL 125 125S3 1 1 1/2"(3)#1/0 N/A 125 125S3 1 1 1/2"(3)#2/0 N/A 125 125F3 1 1 1/2"(3)#1/0 (1)#6 125 125F3 1 1 1/2"(3)#2/0 (1)#4 AL 100 100S3 1 1 1/2"(3)#1 N/A 100 100S3 1 1 1/2"(3)#1/0 N/A 100 100F3 1 1 1/2"(3)#1 (1)#6 100 100F3 1 1 1/2"(3)#1/0 (1)#4 AL 90 90F3 1 1 1/4"(3)#2 (1)#8 80 80F3 1 1 1/4"(3)#3 (1)#8 70 70F3 1 1 1/4"(3)#4 (1)#8 60 60S3 1 1 1/4"(3)#6 N/A 60 60F3 1 1 1/4"(3)#6 (1)#8 50 50F3 1 1"(3)#8 (1)#10 40 40F3 1 1"(3#)8 (1)#10 30 30F3 1 3/4"(3)#10 (1)#10 20 20F3 1 1/2"(3)#12 (1)#12 OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1"(2#)6 (1)#10 50 50F2 1 1"(2#)8 (1)#10 40 40F2 1 1"(2)#8 (1)#10 30 30F2 1 3/4"(2)#10 (1)#10 20 20F2 1 1/2"(2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 4000 4000S4 14 3"(4)500 KCM N/A 4000 4000S4 17 3 1/2"(4)500 KCM N/A 4000 4000F4 14 3"(4)500 KCM (1)500 KCM 4000 4000F4 17 3 1/2"(4)500 KCM (1)500 KCM CU 3000 3000S4 10 3"(4)500 KCM N/A 3000 3000S4 13 3 1/2"(4)500 KCM N/A 3000 3000F4 10 3"(4)500 KCM (1)400 KCM 3000 3000F4 13 3 1/2"(4)500 KCM (1)400 KCM CU 2500 2500S4 9 3"(4)500 KCM N/A 2500 2500S4 11 3 1/2"(4)500 KCM N/A 2500 2500F4 9 3"(4)500 KCM (1)350 KCM 2500 2500F4 11 3 1/2"(4)500 KCM (1)350 KCM CU 2000 2000S4 7 3"(4)500 KCM N/A 2000 2000S4 9 3 1/2"(4)500 KCM N/A 2000 2000F4 7 3"(4)500 KCM (1)250 KCM 2000 2000F4 9 3 1/2"(4)500 KCM (1)400 KCM AL 1600 1600S4 6 3"(4)400 KCM N/A 1600 1600S4 7 3 1/2"(4)500 KCM N/A 1600 1600F4 6 3"(4)400 KCM (1)#4/0 1600 1600F4 7 3 1/2"(4)500 KCM (1)350 KCM AL 1500 1500S4 5 3"(4)500 KCM N/A 1500 1500S4 7 3"(4)400 KCM N/A 1500 1500F4 5 3"(4)500 KCM (1)#4/0 1500 1500F4 7 3"(4)400 KCM (1)350 KCM AL 1200 1200S4 4 3"(4)500 KCM N/A 1200 1200S4 5 3 1/2"(4)500 KCM N/A 1200 1200F4 4 3"(4)500 KCM (1)#3/0 1200 1200F4 5 3 1/2"(4)500 KCM (1)250 KCM AL 1100 1100S4 4 3"(4)500 KCM N/A 1100 1100S4 5 3 1/2"(4)500 KCM N/A 1100 1100F4 4 3"(4)500 KCM (1)#3/0 1100 1100F4 5 3 1/2"(4)500 KCM (1)250 KCM AL 1000 1000S4 4 3"(4)400 KCM N/A 1000 1000S4 5 3"(4)350 KCM N/A 1000 1000F4 4 3"(4)400 KCM (1)#2/0 1000 1000F4 5 3"(4)350 KCM (1)#4/0 AL 900 900S4 3 3"(4)500 KCM N/A 900 900S4 4 3"(4)500 KCM N/A 900 900F4 3 3"(4)500 KCM (1)#2/0 900 900F4 4 3"(4)500 KCM (1)#4/0 AL 800 800S4 3 3"(4)400 KCM N/A 800 800S4 4 3"(4)350 KCM N/A 800 800F4 3 3"(4)400 KCM (1)#1/0 800 800F4 4 3"(4)350 KCM (1)#3/0 AL 700 700S4 3 3"(4)350 KCM N/A 700 700S4 3 3"(4)500 KCM N/A 700 700F4 3 3"(4)350 KCM (1)#1/0 700 700F4 3 3"(4)500 KCM (1)#3/0 AL 600 600S4 2 3"(4)500 KCM N/A 600 600S4 3 3"(4)350 KCM N/A 600 600F4 2 3"(4)500 KCM (1)#1 600 600F4 3 3"(4)350 KCM (1)#2/0 AL 500 500S4 2 3"(4)400 KCM N/A 500 500S4 3 2 1/2"(4)300 KCM N/A 500 500F4 2 3"(4)400 KCM (1)#2 500 500F4 3 2 1/2"(4)300 KCM (1)#1/0 AL 450 450S4 2 2 1/2"(4)300 KCM N/A 400 450S4 2 3"(4)500 KCM N/A 450 450F4 2 2 1/2"(4)300 KCM (1)#2 400 450F4 2 3"(4)500 KCM (1)#1/0 AL 400 400S4 2 2 1/2"(4)250 KCM N/A 400 400S4 2 3"(4)350 KCM N/A 400 400F4 2 2 1/2"(4)250 KCM (1)#3 400 400F4 2 3"(4)350 KCM (1)#1 AL 350 350S4 2 2 1/2"(4)#4/0 N/A 350 350S4 2 2 1/2"(4)300 KCM N/A 350 350F4 2 2 1/2"(4)#4/0 (1)#3 350 350F4 2 2 1/2"(4)300 KCM (1)#1 AL 300 300S4 1 3"(4)500 KCM N/A 300 300S4 2 2 1/2"(4)250 KCM N/A 300 300F4 1 3"(4)500 KCM (1)#4 300 300F4 2 2 1/2"(4)250 KCM (1)#2 AL 250 250S4 1 3"(4)400 KCM N/A 250 250S4 2 2"(4)#4/0 N/A 250 250F4 1 3"(4)400 KCM (1)#4 250 250F4 2 2"(4)#4/0 (1)#2 AL 225 225S4 1 2 1/2"(4)300 KCM N/A 225 225S4 1 3"(4)500 KCM N/A 225 225F4 1 2 1/2"(4)300 KCM (1)#4 225 225F4 1 3"(4)500 KCM (1)#2 AL 200 200S4 1 2 1/2"(4)250 KCM N/A 200 200S4 1 3"(4)350 KCM N/A 200 200F4 1 2 1/2"(4)250 KCM (1)#6 200 200F4 1 3"(4)350 KCM (1)#4 AL 175 175S4 1 2 1/2"(4)#4/0 N/A 175 175S4 1 2 1/2"(4)300 KCM N/A 175 175F4 1 2 1/2"(4)#4/0 (1)#6 175 175F4 1 2 1/2"(4)300 KCM (1)#4 AL 150 150S4 1 2"(4)#3/0 N/A 150 150S4 1 2"(4)250 KCM N/A 150 150F4 1 2"(4)#3/0 (1)#6 150 150F4 1 2"(4)250 KCM (1)#4 AL 125 125S4 1 2"(4)#2/0 N/A 125 125S4 1 2"(4)#4/0 N/A 125 125F4 1 2"(4)#2/0 (1)#6 125 125F4 1 2"(4)#4/0 (1)#4 AL 100 100S4 1 1 1/2"(4)#1/0 N/A 100 100S4 1 1 1/2"(4)#3/0 N/A 100 100F4 1 1 1/2"(4)#1/0 (1)#8 100 100F4 1 1 1/2"(4)#3/0 (1)#4 AL 90 90F4 1 1 1/2"(4)#1/0 (1)#8 80 80F4 1 1 1/4"(4)#1 (1)#8 70 70F4 1 1 1/4"(4)#2 (1)#8 60 60S4 1 1 1/4"(4)#3 N/A 60 60F4 1 1 1/4"(4)#3 (1)#10 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE f.IMPEDENCES ARE BASED ON 2018,2021, AND 2024 IECC MINIMUMS. e.THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. d.NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL FROM AHJ TO DOWNSIZE CONDUCTORS. c.3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. b.AMPACITY BASED UPON NEC, TABLE 301.15.B.16 THWN/EMT CONDUCTORS/RACEWAY TYPES. REVISE ACCORDINGLY FOR OTHER CONDUCTORS OR RACEWAYS. a.THE CONTRACTOR SHALL VERIFY THE SIZE OF EQUIPMENT SUPPLIED DOES NOT EXCEED THE AVAILABLE MOUNTING SPACE, PRIOR TO PURCHASE. GENERAL NOTES: T1A 500 480∆601 800 800F3 208Y/120V 1388 0.85%163,278 2000 (6)4-400 KCM; #3/0GND; 3"C #3/0 - T5A T5B 112.5 480∆135 175 175F3 208Y/120V 312 1.26%24,783 400 (2)4-#3/0; #1/0GND; 2"C #1/0 - T2A, T2B, T3A, T3B, T4A, T4B 75 480∆90 125 125F3 208Y/120V 208 1.4%14,870 225 (1)4-#4/0; #2GND; 2 1/2"C #1/0 - kVA VOLTS FLA OCPD KEY VOLTS FLA IMPEDANCE AVAILABLE SCC OCPD KEY COPPER ELECTRICAL CHARACTERISTICS FEEDER ELECTRICAL CHARACTERISTICS FEEDERTAG PRIMARY SECONDARY GROUNDING ELECTRODE REMARKS THREE PHASE DRY-TYPE TRANSFORMER SCHEDULE SCALE: NO SCALE1ELECTRICAL ONE-LINE - MULTIFAMILY/TOWNHOME - DWELLING SCALE: NO SCALE2ELECTRICAL ONE-LINE - HOUSE LOADS ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d.THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c.WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b.OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a.GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 4000A 700BJ 8BJ 6GEC 3/0GEC 4GEC 3/0GEC 3/0GEC - 2000A 300BJ 8BJ 6GEC 3/0GEC 4GEC 3/0GEC 3/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TOSERVICE RATING FEEDER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE SCALE: NO SCALE3SERVICE GROUNDING SCALE: 1/8" = 1'-0"4 DRY-TYPE TRANSFORMER GROUNDING RCP - RELAY CONTROL PANEL EM - EMERGENCY PANELBOARD P - POOL PANELBOARD TP - TENANT PANELBOARD K - KITCHEN PANELBOARD H - HOUSE PANELBOARD LP - PANELBOARD DP - DISTRIBUTION PANELBOARD T - TRANSFORMER X - 240/120VAC L- 208/120VAC H - 480/277VAC LEVEL - 1, 2, 3, ETC. A, B, C, ETC. LP L 1 A TYPE VOLTAGE FLOOR UNIQUE IDENTIFIER EQUIPMENT NAMING CONVENTION NO.DESCRIPTION DATE 3 50% DESIGN DEVELOPMENT 2025.03.07 NO.DESCRIPTION DATE