Loading...
HomeMy WebLinkAboutPlans - Irrigation Plan - 03/18/2025IRRIGATION SCHEDULE SYMBOL DESCRIPTION MODEL NO. DESCRIPTION DETAIL # AND SHEET IRRIGATION METER 3/4" DEDICATED IRRIGATION METER REFER TO CIVIL, UTILITY, AND WATER PLANS NA NA IRRIGATION CONTROLLER HUNTER HCC-800-M + EZ-DM 120VAC POWER REQUIRED - SEE PLANS FOR LOCATION(S)1 LI501 RAIN SENSOR HUNTER WSS-SEN REFER TO CONTROLLER NOTES 2 LI501 BACKFLOW PREVENTER FEBCO 3/4" 825YA SEE ENCLOSURE SPECIFICATIONS BELOW 3 LI501 NOT SHOWN SECURITY ENCLOSURE GUARD SHACK GS-1 LIFT OFF ENCLOSURE WITH FROSTGUARD BLANKET, POWDER COATED FOREST GREEN 4 LI501 MANUAL DRAIN VALVE MATCO-NORCA 3/4" 201X INSTALLED IN AEP 910L-1G2G VALVE BOX 5 LI501 QUICK COUPLER HUNTER HQ-44RC INSTALLED IN AEP 910L-1G2G VALVE BOX 8 LI501 MASTER VALVE HUNTER IBV-101G-FS SERIES WITH EZ-1 INSTALLED IN AEP 1015-1G2G VALVE BOX 6 LI501 FLOW SENSOR FLOMEC QS-200-10 SERIES WITH COMMUNICATION CABLE BACK TO CONTROLLER, INSTALLED IN AEP 1015-1G2G VALVE BOX 7 LI501 ISOLATION GATE VALVE MATCO-NORCA 514TX MATCH LINE SIZE, INSTALLED IN AEP 910L-1G2G VALVE BOX 9 LI501 TURF VALVE ASSEMBLY HUNTER ICV-G SERIES WITH SCH 40 BALL VALVE, AND EZ-1 DECODER INSTALLED IN AEP 1015-1G2G VALVE BOX, SIZED PER PLAN 3 LI502 DRIP VALVE ASSEMBLY HUNTER ICZ-101-LF WITH SCH 40 BALL VALVE, AND EZ-1 DECODER INSTALLED IN AEP 1320-1G2G VALVE BOX, SIZED PER PLAN 4 LI502 TURF ROTARY HUNTER PROS-06-PRS40-CV WITH HUNTER MP SERIES NOZZLE NOZZLE PER PLAN 5 LI502 TURF ROTARY (SPECIALTY) HUNTER PROS-06-PRS40-CV WITH HUNTER MP SERIES NOZZLE NOZZLE PER PLAN 5 LI502 TURF SPRAY (FIXED) HUNTER PROS-06-PRS30-CV WITH PRO-SPRAY FIXED SERIES NOZZLE NOZZLE PER PLAN 5 LI502 TURF SPRAY (ADJUSTABLE) HUNTER PROS-06-PRS30-CV W/ PRO ADJUSTABLE SERIES NOZZLE NOZZLE PER PLAN 5 LI502 NATIVE SEED ROTARY HUNTER PROS-12-PRS40-CV WITH HUNTER MP SERIES NOZZLE NOZZLE PER PLAN 6 LI502 NATIVE SEED ROTARY (SPECIALTY) HUNTER PROS-12-PRS40-CV WITH HUNTER MP SERIES NOZZLE NOZZLE PER PLAN 6 LI502 NATIVE SEED SPRAY (FIXED) HUNTER PROS-12-PRS30-CV WITH PRO-SPRAY FIXED SERIES NOZZLE NOZZLE PER PLAN 6 LI502 NATIVE SEED SPRAY (ADJ) HUNTER PROS-12-PRS30-CV WITH PRO-ADJUSTABLE SERIES NOZZLE NOZZLE PER PLAN 6 LI502 TREES IN NATIVE HUNTER PROS-04-PRS30-CV WITH PCN-50 BUBBLER TWO (2) ASSEMBLIES PER TREE 6 LI503 SLEEVING CLASS 200 PVC REFER TO SLEEVING NOTES 1 LI502 SERVICE LINE TYPE K COPPER SIZE: MATCH POC UNLESS OTHERWISE NOTED 2 LI502 PVC MAINLINE CLASS 200 PVC BE SIZE: 1-1/2" UNLESS OTHERWISE NOTED 2 LI502 PVC TURF LATERAL CLASS 200 PVC BE SIZE: 1" MINIMUM UNLESS OTHERWISE NOTED 2 LI502 PVC TREE LATERAL CLASS 200 PVC SIZE: 1" UNLESS OTHERWISE NOTED 2 LI502 DRIP LATERAL UV RESISTANT POLYETHYLENE SIZE: 3/4" MINIMUM UNLESS OTHERWISE NOTED 2 LI502 FLUSH END CAP HOSE END FLUSH CAP & OPERATIONAL INDICATOR INSTALLED IN AEP 910L-1G2G VALVE BOX 7 LI503 M C RS DV Q MV FS T M L O K G R B Y A MPCORNER MP1000 MP2000 MP3000 M L O MP800 MP815 MPSTRIP LBMP3500 8 8 8 8 01 01 01 01 21212121 Q T H F 51515151 8 01 21 51 T M OL K G R B Y A MP1000 MP2000 MP3000 MPCORNER LB MP800 MP815 MPSTRIP MP3500 M L O 8 8 8 8 01 01 01 01 21 21 21 21 51 51 51 51 Q T H F 8 01 21 51 VALVE CALLOUT EMITTER SCHEDULE PLANT TYPE EMITTER QTY.TOTAL GPH PERENNIAL / GRASSES 0.5 GPH TWO EACH 1.0 GPH DECIDUOUS SHRUBS 1.0 GPH TWO EACH 2.0 GPH EVERGREEN SHRUBS 1.0 GPH TWO EACH 2.0 GPH DECIDUOUS TREE 1.0 GPH EIGHT EACH 8.0 GPH EVERGREEN TREE 1.0 GPH EIGHT EACH 8.0 GPH TREES IN NATIVE 0.5 GPH TWO EACH 1.0 GPH EMITTER NOTES 1. ALL PLANT MATERIAL SHALL BE IRRIGATED WITH RAIN BIRD XB SERIES PRESSURE COMPENSATING EMITTERS. 2. EMITTER SCHEDULE IS FOR REFERENCE ONLY. THE CONTRACTOR SHALL ADJUST EMITTER AND NUMBER OF EMITTERS BASED ON THE NEEDS OF INDIVIDUAL PLANTS OR PLANT HYDROZONES. 3. 1/4" DISTRIBUTION TUBING NOT TO EXCEED 8' IN LENGTH. 4. RAIN BIRD DBC-025 DIFFUSER BUG CAP AND TS-025 STAKE ON ALL 1/4" DISTRIBUTION TUBING EMISSION POINTS. 5. REFER TO DRIP IRRIGATION DETAILS 1-6, SHEET LI-503 XXX" X - X ZONE DESIGNATION: T (TREES), S (SHRUBS), G (TURF), N (NATIVE), X (MISC) VALVE/STATION NUMBER VALVE FLOW: (GPM) VALVE SIZE IRRIGATION GENERAL NOTES 1.THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO INSTALL THE IMPROVEMENTS SHOWN ON THE PLANS. 2.THE CONTRACTOR SHALL COORDINATE AS NECESSARY WITH THE GENERAL CONTRACTOR AND OWNER'S REPRESENTATIVE FOR SUCCESSFUL COMPLETION OF THIS WORK. 3.ALL IRRIGATION EQUIPMENT IS TO BE AS SPECIFIED OR APPROVED EQUAL PER THE DISCRETION OF THE OWNER'S REPRESENTATIVE. THE CONTRACTOR ASSUMES ALL LIABILITY ASSOCIATED WITH THE MODIFICATION OF THE IRRIGATION SYSTEM DESIGN WITHOUT NOTIFYING THE OWNER'S REPRESENTATIVE. 4.IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONDUCT A THOROUGH SITE INSPECTION AND REVIEW OF THE PROJECT CONSTRUCTION DOCUMENTS INCLUDING BUT NOT LIMITED TO THE FOLLOWING: LANDSCAPE PLAN, UTILITY PLAN, CIVIL UTILITY PLAN, ARCHITECTURE PLAN, GRADING AND DRAINAGE PLAN AND ALL OTHER ASSOCIATED PLANS AND SPECIFICATIONS THAT AFFECT THIS WORK PRIOR TO START OF WORK. IF THE AND CONTRACTOR OBSERVES ANY DISCREPANCIES AMONG THE CONSTRUCTION DOCUMENTS AND THE EXISTING CONDITIONS ON SITE, IT IS THEIR RESPONSIBILITY TO CONTACT THE OWNER'S REPRESENTATIVE IMMEDIATELY. 5.THE CONTRACTOR MUST VERIFY THE LOCATION OF ALL PUBLIC AND PRIVATE UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. IF THE CONTRACTOR FAILS TO DO SO AND DAMAGES ANY UNDERGROUND UTILITIES. THE CONTRACTOR SHALL PAY FOR ANY REPAIR WORK ASSOCIATED WITH SAID DAMAGES. 6.IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ADEQUATE VERTICAL AND HORIZONTAL SEPARATION BETWEEN ALL IRRIGATION DISTRIBUTION LINES AND ALL UTILITIES (EXISTING OR PROPOSED), CONDUIT, STORM WATER COMPONENTS, DRAINS, ETC. 7.THE CONTRACTOR SHALL CONFORM TO ALL LOCAL AND STATE REGULATIONS AND INSTALL THE IRRIGATION SYSTEM AND ITS COMPONENTS PER MANUFACTURER'S SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN AND PROVIDE PAYMENT FOR ALL PERMITS REQUIRED BY ANY LOCAL AND STATE AGENCIES AND UTILITY COMPANIES HAVING JURISDICTION OVER THIS SITE. 8.THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING AND PAYING FOR CERTIFICATION OF THE BACKFLOW PREVENTER BY A STATE CERTIFIED INSPECTOR. THE CONTRACTOR SHALL PROVIDE CERTIFICATES TO OWNER'S REPRESENTATIVE PRIOR TO PROJECT ACCEPTANCE. 9.IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED WITHIN LANDSCAPE AREAS AND WITHIN THE PROJECT LIMITS. EQUIPMENT SHOWN OUTSIDE OF THESE LIMITS IS SHOWN FOR GRAPHIC CLARITY ONLY. IF THERE IS A QUESTION REGARDING THE LOCATION OF ANY COMPONENT OF THE IRRIGATION SYSTEM, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER'S REPRESENTATIVE. IF THE CONTRACTOR NEGLECTS TO NOTIFY THE NECESSARY PARTIES, THE CONTRACTOR SHALL PAY FOR ANY REPLACEMENT OR MODIFICATION TO ENSURE PROPER LOCATION AND OPERATION OF THE IRRIGATION SYSTEM AND ITS COMPONENTS. 10.ALL IRRIGATION DISTRIBUTION LINES AND EQUIPMENT INCLUDING BUT NOT LIMITED TO, MAINLINE, LATERALS, SPRAY HEADS, DRIP EMITTERS SHALL BE KEPT A MINIMUM DISTANCE OF 6' AWAY FROM ALL BUILDING AND WALL FOUNDATIONS, OR AS STIPULATED IN THE GEOTECHNICAL REPORT , WHICHEVER IS GREATER. EQUIPMENT MAY BE SHOWN IN THIS AREA FOR GRAPHIC CLARITY. COORDINATE ALL REQUIRED SETBACKS WITH OWNER'S REPRESENTATIVE PRIOR TO START OF WORK. 11.EACH VALVE SHALL BE INSTALLED IN A SEPARATE VALVE BOX AS DETAILED. ALL VALVE BOXES AND LIDS SHALL BE COMMERCIAL GRADE, PLASTIC WITH SELF LOCKING COVERS. LID COLOR TO BE GREEN. INSTALL FLUSH TO FINISH GRADE AND PER CONSTRUCTION DETAILS. DO NOT INSTALL IN PAVED AREAS OR IN BOTTOMS OF DRAINAGE SWALES/BASINS. 12.CONTRACTOR SHALL INSTALL DETECTABLE MARKING TAPE OR #14g DIRECT BURY TRACER WIRE IN ALL PRESSURE MAINLINE TRENCHES. SEE IRRIGATION DETAILS FOR MORE INFORMATION. 13.PLANT MATERIAL LOCATIONS TAKE PRECEDENCE OVER ROUTING OF IRRIGATION PIPING. COORDINATE INSTALLATION OF IRRIGATION EQUIPMENT SO THAT IT DOES NOT INTERFERE WITH THE PLANTING OF TREES OR OTHER LANDSCAPE MATERIAL. 14.THE CONTRACTOR SHALL MARK THE LOCATION OF THE MAINLINE, CONTROL VALVES, GATE VALVES AND HEAD LAYOUT OF A REPRESENTATIVE SPRAY ZONE. SCHEDULE A REVIEW WITH THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 15.INSTALL SCH. 40 BALL WITH OPERATIONAL INDICATOR AT ENDS OF ALL DRIP LATERALS AS DETAILED. FLUSH ALL LATERALS THOROUGHLY BEFORE INSTALLING EMITTERS AND BUBBLERS. 16.CONTRACTOR SHALL FINE TUNE AND ADJUST NOZZLE DIRECTION AND RADIUS TO REDUCE OVERSPRAY ONTO PAVING OR HARD SURFACES. 17.CONTRACTOR SHALL INSTALL A QUICK COUPLER IN 10" VALVE BOX AT THE END OF ALL BRANCHES OF THE MAINLINE, OR AS SHOWN ON PLANS, FOR WINTERIZATION AND FLUSHING OF MAINLINE. 18.THE CONTRACTOR SHALL PERFORM A PRESSURE TEST ON ALL MAINLINES. CONTRACTOR SHALL PRESSURIZE MAINLINES TO 120 PSI AND MAINTAIN PRESSURE AT 120 PSI FOR A MINIMUM CONTINUOUS PERIOD OF TWO (2) HOURS TO ACHIEVE FINAL ACCEPTANCE. 19.THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO OPERATE DURING A THREE(3) NIGHT PER WEEK, SIXTEEN(16) HOURS PER NIGHT WATERING WINDOW. DRIP IRRIGATION ZONES MAY BE ALLOWED TO RUN ON A SEPARATE SCHEDULE FROM THIS WATER WINDOW DEPENDING JURISDICTION. LANDSCAPE ESTABLISHMENT WILL REQUIRE INCREASED IRRIGATION WATER FOR DURATION OF THE ESTABLISHMENT PERIOD AND MAY REQUIRE TWICE THE AMOUNT OF WATER AS ESTABLISHED PLANT MATERIAL. THE CONTRACTOR SHALL COORDINATE WATERING SCHEDULES AND APPLICATION RATES WITH THE OWNER'S REPRESENTATIVE PRIOR TO FINAL ACCEPTANCE. 20.THE DESIGN IS BASED ON THE FOLLOWING PROJECTED PEAK SEASON WEEKLY APPLICATION RATES AFTER ESTABLISHMENT. THESE FIGURES WILL NEED TO BE ADJUSTED DUE TO SEASONAL CHANGES AND VARIABLE WEATHER CONDITIONS. ·FESCUE/BLUEGRASS BLEND TURF 1.75" PER WEEK PEAK SEASON ·TREE, SHRUB, AND PERENNIAL PLANT MATERIAL 1.00" PER WEEK PEAK SEASON ·NATIVE DRAUGHT TOLERANT SEED MIX 0.75" PER WEEK PEAK SEASON 21.THE CONTRACTOR SHALL PROVIDE A SEASONAL MAINTENANCE SCHEDULE WHICH SHALL BEGIN ON APRIL 15TH AND END ON OCTOBER 15TH TO ENSURE THE EFFICIENCY AND LONGEVITY OF THE IRRIGATION SYSTEM. THE MAINTENANCE SCHEDULE SHALL INCLUDE BUT IS NOT LIMITED TO THE FOLLOWING LIST OF BEST MANAGEMENT PRACTICES: ·CHECK HEADS FOR COVERAGE AND LEAKAGE. ·CHECK CONTROLLER PROGRAMMING AND ADJUST FOR SEASONAL CHANGES AS NECESSARY. ·VERIFY THAT THE WATER SUPPLY AND PRESSURE ARE AS STATED IN THE DESIGN. ·CERTIFY THE BACKFLOW PREVENTION DEVICE AND SUBMIT TEST RESULTS TO THE PROPERTY MANAGER. ·PERIODICALLY VERIFY THE THE SENSORS IN THE IRRIGATION SYSTEM ARE OPERATING CORRECTLY. ·WINTERIZATION AND SPRING START UP PROCEDURES. IRRIGATION POINT OF CONNECTION NOTES 1.POINT OF CONNECTION: THERE IS ONE (1) POINT OF CONNECTION ON THIS PROJECT. POC #1 : 3/4" DEDICATED IRRIGATION WATER METER LOCATED OFF PROSPECT AVENUE NEAR THE SOUTHERN COURTYARD. ·CONTRACTOR IS TO LOCATE AND CONNECT DOWNSTREAM OF THE DEDICATED POTABLE IRRIGATION WATER METER (PROVIDED BY OTHERS) WITH TYPE K COPPER AT A DEPTH OF 48" OR PER LOCAL CODE, WHICHEVER IS GREATER. EXTEND COPPER TO BACKFLOW PREVENTION UNIT. EXTEND COPPER TUBING MINIMUM 30" HORIZONTAL FROM BACKFLOW PREVENTER AND INSTALL ONE MANUAL DRAIN, TRANSITION TO AND EXTEND CLASS 200 PVC MAINLINE TO THE 1" QUICK COUPLER, MASTER VALVE, FLOW SENSOR, GATE VALVE, AND EXTEND MAINLINE TO VALVES AS SHOWN. ·ALL PIPING FROM THE DEDICATED IRRIGATION POTABLE METER THROUGH DRAIN VALVE DOWNSTREAM OF THE BACKFLOW PREVENTION UNIT SHALL BE THE SAME SIZE AS THE METER UNLESS OTHERWISE NOTED. ·THE CONTRACTOR SHALL CONFORM TO ALL LOCAL CODES, OBTAIN AND PROVIDE PAYMENT FOR ALL PERMITS ASSOCIATED WITH THIS WORK. FINAL LOCATION OF BACKFLOW PREVENTION UNIT SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 2.CONTROLLER LOCATION: THERE IS ONE (1) CONTROLLER ON THIS PROJECT. CONTROLLER A : WALL MOUNTED CONTROLLER LOCATED ADJACENT TO POC. ·CONTROLLER SHALL BE PROGRAMMED TO RUN MULTIPLE VALVES AT ONE TIME WITH A MAXIMUM TOTAL OF 10 GPM . ·CONTROLLER, TO BE MOUNTED PER DETAILS AND MANUFACTURER'S SPECIFICATIONS. ·CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE AND ELECTRICAL PLANS FOR POWER SERVICE. ALL ELECTRICAL EQUIPMENT AND POWER CONNECTION INSTALLATION SHALL CONFORM TO ALL LOCAL CODES. INSTALL A LINE VOLTAGE SURGE DEVICE (INTERMATIC AG2401C3/ OR SQUARE D SDSA1175) FOR 120V IN A JUNCTION BOX PRIOR TO CONTROLLER. ·RAIN/FREEZE SENSOR: MOUNT THE RAIN SENSOR ON ADJACENT LIGHT POLE IN PROXIMITY TO THE CONTROLLER. THE SENSOR SHALL BE MOUNTED IN A LOCATION IN FULL SUN AND OPEN TO RAINFALL. SENSOR SHALL BE NO MORE THAN 200' FROM WIRELESS RECEIVER. MOUNT WIRELESS RECEIVER ON OR ADJACENT TO THE IRRIGATION CONTROLLER. 3.SYSTEM PRESSURE: THE SYSTEM HAS BEEN DESIGNED PER THE FOLLOWING SPECIFICATIONS: REQUIRED MINIMUM STATIC PRESSURE OF 70 PSI AND MAXIMUM SAFE VELOCITY OF 5 FPS IN ANY PVC PIPE AND 7.5 FPS IN ANY COPPER PIPE. ·PER (WATER PURVEYOR/CITY WATER) THE STATIC PRESSURE ON SITE IS APPROXIMATELY TBD PSI. ·THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE PRESSURE IN THE FIELD AT THE POINT OF CONNECTION BEFORE CONSTRUCTION BEGINS AND FOR NOTIFYING THE OWNER'S REPRESENTATIVE OF ANY DISCREPANCY BETWEEN THE DESIGN PRESSURE OF THE SYSTEM AND THE MEASURED PRESSURE IN THE FIELD. IF THE CONTRACTOR FAILS TO NOTIFY OWNER'S REPRESENTATIVE OF SUCH DISCREPANCIES, THEN THE CONTRACTOR ASSUMES ALL LIABILITY AND COSTS ASSOCIATED WITH SYSTEM MODIFICATIONS TO ACCOMMODATE THE ACTUAL PRESSURE. ·FLOW SENSOR: SENSOR REQUIRES A MINIMUM FLOW FOR PROPER READINGS. MULTIPLE ZONES MAY BE REQUIRED TO RUN SIMULTANEOUSLY TO ACHIEVE THE MINIMUM FLOWS REQUIRED. CONTRACTOR TO SET 'K' VALUES PER MANUFACTURER. 4.FLOW SENSOR REQUIRES A MINIMUM FLOW OF 0.22 GPM. 5.COMMUNICATION: IT IS RECOMMENDED THAT THE IRRIGATION CONTROLLER BE CONNECTED TO A WATER MANAGEMENT CONTROL SOFTWARE FOR OPTIMUM FUNCTION OF THE IRRIGATION SYSTEM. COORDINATE WITH OWNER'S REPRESENTATIVE AND CONTACT THE LOCAL CONTROLLER MANUFACTURER REPRESENTATIVE OR AUTHORIZED VENDOR PRIOR TO ORDERING CONTROLLER FOR COMMUNICATION AND CONNECTIVITY OPTIONS. TWO WIRE NOTES 1.GROUNDING FOR THE IRRIGATION CONTROLLER AND DECODERS ARE TO BE INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS AND PER THE AMERICAN SOCIETY OF IRRIGATION CONSULTANTS GUIDELINE 100-2002 FOR EARTH GROUNDING ELECTRONIC EQUIPMENT IN IRRIGATION SYSTEMS FOUND AT WWW.ASIC.ORG. FOR ADDITIONAL TECHNICAL SUPPORT REGARDING THE IRRIGATION CONTROLLER OR GROUNDING PLEASE CONTACT THE MANUFACTURER. 2.DO NOT LOOP TWO WIRE PATH. STAR PATTERN FROM CONTROLLER FOR EACH BRANCH OF MAINLINE. 3.CONTRACTOR IS RESPONSIBLE FOR GROUNDING THE CONTROLLER INDEPENDENTLY FROM BUILDING. 4.THE TWO-WIRE CONTROLLER REQUIRES EACH CONTROL VALVE AND SENSOR TO HAVE A DECODER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE PROPER DECODERS, SURGE SUPPRESSION AND GROUNDING. THE RAIN SENSOR AND FLOW SENSOR REQUIRE A SENSOR DECODER. 5.QTY OF STATIONS (VALVES) PER MANIFOLD REQUIRED DECODER ·SINGLE STATION EZ-1 (HUNTER) ·CONTROLLER TWO-WIRE PATH SHALL BE MANUFACTURER'S APPROVED WIRE OR APPROVED EQUAL. 6.CONTRACTOR SHALL USE UL APPROVED WIRE STRIPPER AND WATERPROOF CONNECTIONS (DBR/Y OR APPROVED EQUAL) AT ALL SPLICES AND CONNECTIONS POINTS. 7.PROVIDE 30" MINIMUM TWO WIRE PATH IN EACH VALVE BOX FOR MAINTENANCE. 8.CONTRACTOR SHALL INCLUDE TWO-WIRE RUN PATHS ON AS-BUILT DRAWINGS. SLEEVING COORDINATION NOTES 1.INSTALLATION OF IRRIGATION SLEEVING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE IRRIGATION CONTRACTOR FOR LOCATION AND SIZING OF SLEEVES PRIOR TO THE START OF CONSTRUCTION. 2.SLEEVES SHALL BE INSTALLED PRIOR TO THE START OF PAVING OPERATIONS. 3.THE CONTRACTOR SHALL SLEEVE ALL IRRIGATION DISTRIBUTION LINES, VALVE CONTROL WIRES AND COMMUNICATION WIRES UNDER ALL PAVED SURFACES, WALL FOOTERS, DRAINAGE CHANNELS, INLETS, CATCH BASINS, ETC. 4.ALL SLEEVES SHALL EXTEND A MINIMUM OF 12" BEYOND EDGE OF ALL OBSTRUCTIONS. NO TEES, ELLS OR OTHER TURNS IN PIPING SHALL BE LOCATED UNDER ANY OBSTRUCTIONS. 5.EACH PIPE SHALL BE IN A SEPARATE SLEEVE. WIRES SHALL BE IN A SEPARATE PIPE UNDER ALL PAVED SURFACES. 6.SLEEVING SHALL BE INSTALLED PER THE SIZES AND QUANTITIES SHOWN ON THE PLANS BASED ON THE CHART BELOW. PIPING REQUIRED SLEEVE SIZE MAINLINE PIPING 3" CLASS 200 PVC LATERAL PIPING 2X NOMINAL DIAMETER OF LATERAL CONTROL WIRES 2" CLASS 200 PVC LI-001 PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 IRRIGATION NOTES AND SCHEDULE T TT VI S I T O R VI S I T O R VI S I T O R VA N VI S I T O R SS C.O. C.O. E E E E E E E E E E E E E E E E E E E E E E E E E E X X X X X X X X X X X X X X X X X T T T TCTVCTVCTVCTV TCT V T T T T CTV CTV CTV CTV G G G G G G G G G G G G G G WAT WAT WAT WAT WAT WAT WAT G G G G G G G G G G G G G W W W W W W W W W W W W W SIZE: FLOW: PRESSURE: POC TBD PSI 10 GPM 3/4-INCH #1 M DV MV FS Q A CONTROLLER 120 VAC REQUIRED A Q Q NORTH 0 4020 80 SCALE 1" = 40' W LAKE STREET W PROSPECT AVE PROPOSED BUILDING PROPOSED BUILDING LAKE STREET GARAGE ROCKY MOUNTAIN RESEARCH STATION LI101 LI102 PR O P E R T Y L I N E PROPOSED PARKING GARAGE PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-100 OVERALL IRRIGATION PLAN SYMBOL CODE DESCRIPTION QTY H-01 LOW WATER 32,570 SF H-02 HIGH WATER 4,316 SF WATER USE TABLE VI S I T O R VI S I T O R VI S I T O R VA N VI S I T O R SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS C.O. C.O. C.O. C C E E E E E E E E E E E E E E E E E E E E E X X X X X X X X X X X X X T T T T T TCTVCTVCTVCTVCTVCTV TCT V T T T T T T CTV CTV CTV CTV CTV CTV EE WAT WAT WAT WAT WAT WAT WAT WAT WAT WAT WAT G G G G G G G G G G G G G G G G G G Q NORTH 0 2010 40 SCALE 1" = 20' MATCHLINE; SEE SHEET: LI102 PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-101 IRRIGATION PLAN T TT E E E E E E E E E E E E E E E E E E E E X X X X X X X X X X X X X X G G G G G G G G G G G G G G G G G G G G G GWWWWWWWWWWWWWWWWW W W SIZE: FLOW: PRESSURE: POC TBD PSI 10 GPM 3/4-INCH #1 M DV MV FS Q A CONTROLLER 120 VAC REQUIRED A Q MATCHLINE; SEE SHEET: LI101 NORTH 0 2010 40 SCALE 1" = 20' PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-102 IRRIGATION PLANW PROSPECT AVE 1 2 NOTE: 1.ALL ELECTRICAL AND CONTROLLER WIRE TO BE INSTALLED PER LOCAL CODE AND MANUFACTURER'S SPECIFICATIONS. 2.GROUND CONTROLLER PER LOCAL CODE AND MANUFACTURER'S SPECIFICATIONS. 3.PROVIDE WATERPROOF SEALANT FOR ALL CONDUIT AND WIRE ACCESS POINTS. 4.PROVIDE LOCK FOR ENCLOSURE. 3 5 6 7 8 9 4 VARIES OPEN 10 CONTROLLER MOUNT AT EYE-LEVEL PER MANUFACTURER'S RECOMMENDATIONS DISCONNECT SWITCH 120 POWER SOURCE IN STEEL CONDUIT WIRELESS SENSOR RECEIVER BUILDING EXTERIOR WALL RIGID STEEL CONDUIT W/ CONTROL WIRES TO VALVES FINISH GRADE CONDUIT TO EXTEND 5 FT. BEYOND WALL UF DIRECT BURIAL WIRE TO CONTROL VALVES UF DIRECT BURIAL WIRE TO GROUNDING PER ASIC GUIDELINES 1 2 3 4 5 6 7 8 9 10 CONTROLLER WALL MOUNT EXTERIOR NTS 1 2 3 SUITABLE FASCIA, WALL, OR GUTTER MOUNT. MOUNT IN LOCATION WHERE SENSOR CAN RECEIVE FULL SUN AND IS OPEN TO RAINFALL. WIRELESS RAIN SENSOR, LOCATE WITHIN 500' OF THE CONTROLLER. SECURE MOUNTING BRACKET TO EXTERIOR WALL WITH SCREWS PER LOCAL CODES 1 2 3 NOTE: 1.PROVIDE WATERPROOF SEALANT FOR ALL CONDUIT AND WIRE ACCESS POINTS. 2.FINAL LOCATION AND MOUNTING SYSTEM TO BE DETERMINED BY OWNER. 3.SENSOR SHOULD NOT BE MOUNTED UNDER TREES, IN AREAS AFFECTED BY SPRINKLER SYSTEM OR UNDER EAVE OF HOUSE. RAIN SENSOR SURFACE MOUNT NTS 4" MIN. 12" FLOW TO VALVES FLOW FROM P.O.C. 1 2 8 3 4 9 10 11 6 12 7 BACKFLOW ENCLOSURE BALL VALVE BRASS UNION TYPE K COPPER PIPE COMPACTED SUBGRADE PVC ADAPTOR 30" BEYOND UNIT PVC MAINLINE REDUCED PRESSURE BACKFLOW PREVENTER WITH BALL VALVES BRASS RISER BRASS WYE STRAINER (100 MESH) COPPER ADAPTER FINISH GRADE 1 2 3 4 5 6 7 8 9 10 11 12 5 NOTE: 1.INSTALL PER LOCAL CODES AND MANUFACTURER'S SPECIFICATIONS. 2.PROVIDE PVC PIPE PROTECTION AROUND COPPER SUPPLY LINES AS THEY GO THROUGH THE CONCRETE SLAB BASE. 3.BACKFLOW PREVENTION DEVICES SHALL BE PLACED A MINIMUM OF TWO (2') FEET FROM THE WATER METER AND BE THE SAME SIZE AS THE METER SERVICE LINE. 4.PROVIDE THRUST BLOCKS FOR LINES 2-1/2" OR LARGER. BACKFLOW FEBCO 825YA SCALE: 1/2" = 1'-0" STANDARD LIFT-OFF GUARDSHACK INTERNAL DIMENSIONS CONCRETE HOLE OPENING GS-.5 10"W x 18"H x 12"L 8"W x 21"L GS-1 10"W x 24"H x 22"L 8"W x 21"L GS-2 10"W x 24"H x 30"L 8"W x 29"L NOTE: 1.INSTALL GUARDSHACK LIFT-OFF UNIT 51 POWDER COATED STEEL GUARD SHACK PER MANUFACTURER'S SPECIFICATIONS. 2.ALL BOLTS FOR MOUNTING BRACKETS SHALL BE ZINC PLATED TAMPER PROOF. 3.PRODUCT AVAILABLE FROM GUARDSHACK 3831 E. GROVE ST. PHOENIX, AZ 85040, PH: (602) 426-1002 EXT. 422 FX: (602) 426-1005 4.PROVIDE KEYED PADLOCK, MASTER LOCK MODEL #957 W/ (2) TWO KEYS FOR LOCKING SECURITY ENCLOSURE. LIFT-OFF GUARDSHACK ENCLOSURE LOCK SHIELD CONCRETE PAD - PAD TO BE 9" LARGER ON ALL SIDES FROM INTERIOR DIMENSIONS OF GUARDSHACK ENCLOSURE FINISH GRADE 3/4" CRUSHED GRAVEL, CONCRETE HOLE OPENING DIMENSION PER CHART 1 2 3 4 5 1 2 3 H L W9"9" 6" H 4 W 9" 9" L 1 2 3 5 9"9" BACKFLOW ENCLOSURE LIFT-OFF SCALE: NTS PLANVIEW 4 3 2 1 NOTE: 1.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 2.LOCATE DRAIN VALVE AT POINT OF CONNECTION AND AT ALL LOW POINT(S) ALONG THE IRRIGATION MAINLINE AS NEEDED. 5 6 7 8 9 10 11 12 13 MANUAL DRAIN VALVE SCALE: NTS 10" LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE. 2" VALVE MARKER 2" CL160 PVC ACCESS SLEEVE LENGTH AS REQUIRED. 3" DEPTH 3/4" CRUSHED GRAVEL 6" BEYOND EDGE OF BOX PVC PRESSURE MAIN LINE SCH. 80 TEE PER MAINLINE SIZE. ALIGN IN A DOWNWARD POSITION SCH. 80 PVC NIPPLE FINISH GRADE 1" BRONZE STOP VALVE WITH SLOTTED KEY OPERATOR SCH. 80 PVC ELL SCH. 80 PVC NIPPLE 3/4" GRAVEL SUMP - 1 CU. FT. MIN SOIL BLANKET ENCLOSING SUMP AMOCO ENG. FABRIC 4545 - 4.5 OZ. OR EQUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 PVC MAINLINE SCH. 80 PVC MALE ADAPTER SCH. 80 PVC BALL VALVE FINISH GRADE LOCKING VALVE BOX SCH. 80 PVC NIPPLE (THREADED) MASTER VALVE WATERPROOF ELECTRICAL CONNECTIONS DECODER WIRES TO CONTROLLER BRICK SUPPORTS 2 MIN. 3/4" GRAVEL SUMP - 8" DEPTH COMPACTED SUBGRADE SCH. 80 PVC UNION (THREADED) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3" MIN. 4 MASTER VALVE SCALE: NTS 1 2 3 5 6 7 9 10 1 11 12 13 6 NOTE: 1.INSTALL MASTER VALVE PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND GROUNDING. 8 14 2 MINIMUM UPSTREAM DISTANCE 10x FLOW METER SIZE OF CLEAN STRAIGHT PIPE MINIMUM DOWNSTREAM DISTANCE 5x FLOW METER SIZE OF CLEAN STRAIGHT PIPE FLOW WIRES TO CONTROLLER LOCKING VALVE BOX WATERPROOF ELECTRICAL CONNECTIONS SENSOR DECODER FLOW SENSOR PER SCHEDULE DOWNSIZED MAINLINE FINISH GRADE SCH. 80 PVC ECCENTRIC COUPLING (S x S) - SIZE & QTY TO BE DETERMINED IN FIELD SCH. 80 PVC NIPPLE (MPT x S) SCH. 80 PVC UNION (THREADED) PVC MAINLINE SCH. 80 PVC MALE ADAPTER TO EARTH GROUND, INSTALLED PER ASIC GUIDELINES 3/4" GRAVEL SUMP 8" DEPTH BRICK SUPPORTS 2 MIN. COMPACTED SUB-GRADE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16FLOW SENSOR DECODER SCALE: NTS NOTE: 1.INSTALL FLOW SENSOR AND SENSOR DECODER PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND GROUNDING. 1 3 5 6 7 8 10 14 15 16 9 1111109842 13 12 LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE FINISH GRADE 8" SCH 40 PVC ACCESS SLEEVE LENGTH AS REQUIRED. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC PER SCHEDULE 3/4" GRAVEL SUMP FILL IN AND AROUND BOX AS REQUIRED. 3" DEPTH 3/4: GRAVEL EXTEND 6" BEYOND EDGE OF BOX PVC MAINLINE COMPACTED SUBGRADE 1 2 3 4 5 6 7 8 NOTE: 1.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.DO NOT REST VALVE BOX OR ACCESS SLEEVES ON MAINLINE OR LATERAL LINE. 3.PROVIDE GATE VALVE KEY - LENGTH AS REQUIRED. CL GATE VALVE 2" AND SMALLER SCALE: NTS 4" M I N . 2" MI N . SE E T R E N C H I N G D E T A I L FO R P I P E D E P T H 4 3 2 1 6 7 5 8 FINISH GRADE 10" ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO FLUSH WITH FINISH GRADE QUICK COUPLING VALVE W/ LOCKING COVER PER SCHEDULE SCH. 80 PVC RISER (T x T) 3" DEPTH 3/4" GRAVEL BASE EXTEND 6" BEYOND EDGE OF BOX PVC SWING JOINT PVC MAINLINE 24" LONG #4 REBAR TO HOLD QUICK COUPLER IN PLACE W/ (2) STAINLESS STEEL CLAMPS 1 2 3 4 5 6 7 8 QUICK COUPLER SCALE: NTS NOTES: 1.EACH QUICK COUPLER SHALL BE IN A SEPARATE VALVE BOX. 2.PROVIDE (1) QUICK COUPLER KEY FOR EACH QUICK COUPLER VALVE. 3.QUICK COUPLER SHALL HAVE LOCKING RUBBER COVER. COLOR PER LEGEND. 4.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE. 5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 2 3 4 5 6 7 8 1 4 7 2 5 8 3 6 9 PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-501 IRRIGATION DETAILS FINISH GRADE POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 POP-UP SPRAY SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 PAVING WRAP 12 GAUGE GALVANIZED WIRE AROUND EACH END OF SLEEVE (10 WRAPS MIN.) AND EXTEND TO SURFACE AS A LOCATING DEVICE FINISH GRADE / TOP OF DG COMPACT SOIL AROUND SLEEVE TO SAME DENSITY AS ADJACENT UNDISTURBED SOIL WASHED AND GRADED MORTAR SAND BACKFILL IN ROCKY SOIL CONDITIONS PVC SLEEVE PER SCHEDULE, TWICE DIAMETER OF THE SUM OF THE PIPES/ WIRES EXTEND SLEEVES 6" BEYOND EDGES OF PAVING 1 2 3 4 5 6 7 NOTE: 1.ALL SLEEVES SHALL BE INSPECTED PRIOR TO BACKFILLING. 2.CAP SLEEVES UNTIL USE. 3.MULTIPLE SLEEVES REQUIRE 4" HORIZONTAL SEPARATION WITHIN SAME SLEEVE TRENCH. 4.IRRIGATION PIPE AND WIRE SHALL NOT SHARE THE SAME SLEEVE. 5.MARK / STAMP - 'X' AND/OR INSTALL PLACARD AT BACK OF CURB. 6" MIN. 18" MIN. DEPTH 24" MIN. DEPTH FOR MAINLINE 1 2 3 4 5 6 7 PIPE SLEEVE SCALE: NTS SNAKE PVC OR POLYETHYLENE PIPE IN TRENCH EXCAVATED COVER MATERIAL (SEE NOTES) FINISH GRADE/TOP OF MULCH POLYETHYLENE DRIP LATERAL (INSTALL JUST BELOW ROUGH GRADE TO PROVIDE UV COVER PRIOR TO MULCH LAYER) MAINLINE MARKING TAPE (PURPLE MARKING TAPE IF RECLAIMED) IRRIGATION SPRAY LATERAL PIPE 12" DEPTH FOR SPRAY LATERALS 18" FOR ROTOR LATERALS IRRIGATION MAINLINE PIPE VALVE WIRING. BUNDLE AND TAPE PER IRRIGATION NOTES BEDDING MATERIAL (SEE NOTES) 1 2 3 4 5 6 7 8 9 NOTE: 1.ALL MAINLINES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER' SPECIFICATIONS. 2.ALL PVC PIPING TO BE SNAKED IN TRENCHES AS SHOWN IN PLAN VIEW ABOVE. 3.PROVIDE HORIZONTAL OFFSET FOR PIPING IN SHARED TRENCHES. 4.ALL 120 VOLT WIRING IN CONDUIT TO BE INSTALLED AS PER LOCAL CODES. 5.ALL ELECTRICAL WIRE CONNECTIONS TO VALVES AND SPLICES TO BE INSTALLED WITHIN A VALVE BOX AND MADE WITH DBY WATERPROOF CONNECTORS, OR APPROVED EQUAL. 6.BUNDLE AND TAPE CONTROLLER WIRING PER NOTES AND INSTALL WITHIN MAINLINE TRENCH WHEREVER POSSIBLE. 7.CONTROLLER WIRE TO BE BURIED AT 18" MIN DEPTH IF NOT LOCATED WITH MAINLINE. 8.MANILINE BEDDING MATERIAL SHALL BE 1/4” MINUS SAND, AND SHALL BE 3” BELOW PIPE OR WIRE AND 3” ABOVE MAINLINE. 9.BEDDING IS NOT REQUIRED IN POLYETHYLENE TUBING TRENCHES OR SHARED TRENCHES. 10.EXCAVATED COVER MATERIAL SHALL BE FREE FROM DEBRIS AND ROCKS 1/2” OR GREATER. SECTION PIPE TRENCH SCALE: NTS 1 9 3 8 7 6 4 2 5 24"12"/18" 10" PLAN 10' 4" 6" 8 PVC MAINLINE BRICK SUPPORT (4 MIN.) CONTROL WIRE COMMON WIRE TO NEXT VALVE(S) PVC LATERAL W/ MALE ADAPTER SCH. 80 PVC UNION (THREADED) WATERPROOF CONNECTORS TWO-WIRE DECODER CONTROL VALVE (4) SCH. 80 PVC NIPPLE/ RISER (LENGTH & SIZE VARY) SCH. 80 PVC BALL VALVE LOCKING VALVE BOX FINISH GRADE PVC ELBOW (TxT) 3/4" GRAVEL SUMP - 4" DEPTH PVC TEE (SxSxT) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3" FLOW CONTROL VALVE WITH DECODER SCALE: NTS NOTE: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS WITH WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE, COILED AND PLACED IN BOX AT WATERPROOF CONNECTION TO SOLENOID. 3.INSTALL DECODER PER MANUFACTURE'S SPECIFICATIONS FOR WIRING AND GROUNDING. 12 13 14 15 3 7 1 6 5 2 4 9 10 11 16 10 3 8 FLOW WATERPROOF CONNECTORS 30" COIL OF WIRE MINIMUM PLACED IN BOX (2) SCH. 80 PVC UNION (THREADED) PVC COUPLING (FPTxFPT) PVC LATERAL BRICK SUPPORT (4 MIN) 4" DEPTH GRAVEL SUMP VALVE BOX PER IRRIGATION SCHEDULE, FLUSH TOP OF BOX W/ GRADE CONTROL VALVE SCH. 80 PVC BALL VALVE CONTROL AND COMMON WIRES FROM CONTROLLER SCH. 80 TEE (SxSxT) PVC MAINLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 DRIP CONTROL ZONE KIT WITH DECODER SCALE: NTS NOTES: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS w/ WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE COILED AND PLACED IN BOX AT WATER PROOF CONNECTION TO SOLENOID. 3.INSTALL DECODERS PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND GROUNDING. Drip valve to poly connection Refer to schedule for type of connection required. POLY PVC TO POLY FITTING Drip valve to pvc connection Refer to schedule for type of connection required. 3" 1 2 3 4 5 9 10 11 12 13 6 8 7 FINISH GRADE 12" POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE PER SCHEDULE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS HEAD SHALL BE LEVEL WITH SURROUNDING FINISHED GRADE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 12 INCH POP-UP SPRAY SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 1 4 2 5 3 6 PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-502 IRRIGATION DETAILS 1 2 1/4" DISTRIBUTION TUBING. RUN TUBING UNDER WEED BARRIER FABRIC TO PLANT. LENGTH NOT TO EXCEED 8' UNIVERSAL 1/4" STAKE DIFFUSER CAP TOP OF MULCH PRESSURE COMPENSATING EMITTER PER EMITTER SCHEDULE. INSTALL EMITTER AT 45° TO 60° ANGLE 3/4" POLYETHYLENE TUBING SET WITH TOP OF TUBING FLUSH WITH FINISH GRADE OF SOIL FINISH GRADE OF SOIL WEED BARRIER FABRIC 1 2 3 4 5 6 7 8 SINGLE OUTLET EMITTER SCALE: NTS 1 2 3 4 7 5 6 8 3 SINGLE OUTLET EMITTER PLACEMENT SCALE: NTS DIFFUSER CAP W/ DRIP STAKE PLANT CENTER PLANT ROOTBALL SINGLE OUTLET EMITTER 3/4" POLYETHYLENE DRIP TUBING 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 1 2 3 4 5 6 NOTE: 1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL. 2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION. 2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT. 3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE. 4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS AND SUN EXPOSURE. 5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. 1 2 3 4 5 6 1 3 6 56 EMISSION POINT. DIFFUSER CAP W/ DRIP STAKE (TYP.) PLANT ROOT BALL (TYP.) PLANT CENTER (TYP.) SECOND EMISSION POINTS SEE NOTE 3 BELOW TREE TRUNK MULCH LAYER 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 3/4" POLYETHYLENE DRIP TUBING SINGLE OUTLET EMITTER ROOTBALL 1 2 3 4 5 6 7 8 9 10 TREE EMITTER PLACEMENT SCALE: NTS 60°60° 60°60° 60 ° NOTE: 1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'. 2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE. 3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3" CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT. 4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY. CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS NECESSARY FOR PROPER PLANT WATER REQUIREMENT. 1 2 3 4 5 1 6 7 8 9 10 6" MIN. 12" MAX. 8 7 10 5 6 FINISH GRADE POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL, (S x T) TREE ROOT BALL FULL CIRCLE BUBBLER (MODEL PER LEGEND) 1 2 3 4 5 6 7 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 24" FROM ROOT BALL. 3.ADJUST ALL SPRINKLERS BODIES SO THAT NO FLODDING OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE. 6 POP-UP BUBBLER SCALE: NTS 18" MIN. 24" MAX. 5 1 2 3 4 7 NOTE: 1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.INSTALL OPERATIONAL INDICATOR WITHIN 24" OF FLUSH VALVE. 3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 7 2 8 3 4 5 6 12" MIN. POP-UP HEAD WITH ENCLOSED NOZZLE AND SWING PIPE. (ZONE OPERATIONAL INDICATOR) LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE 3/4" SCH. 40 PVC BALL VALVE FINISH GRADE 3/4" MxI MALE ADAPTER W/ CLAMPS 3/4" POLYETHYLENE DRIP TUBING - 24" COIL IN BOX FOR MAINTENANCE BRICK (2 REQUIRED MIN.) 3/4" GRAVEL SUMP, 4" DEPTH 1/2" SCH. 80 NIPPLE (LENGTH AS NEEDED) 3/4"x3/4"x1/2" IxIxF INSERT TEE POLY LATERAL 1 2 3 4 5 6 7 8 9 10 11 DRIP FLUSH VALVE WITH OPERATIONAL INDICATOR SCALE: NTS 9 10 11 PROSPECT PLAZA No.Description Date SHEET: DATE: PROJECT: 3575 RINGSBY CT. SUITE 411 DENVER, CO 80216 (720) 677-7766 1 SPAR (ROUND 1) 11-15-2024 03-18-2025 CONSULTANTS PROSPECT PLAZA REDEVELOPMENT SCALE: AS NOTED 2 SPAR REVISION 01-20-2025 REDEVELOPMENT 3 FDP (ROUND 1) 3-18-2025 LI-503 IRRIGATION DETAILS