No preview available
HomeMy WebLinkAboutBLOOM FILING THREE - FDP250003 - SUBMITTAL DOCUMENTS - ROUND 1 - Irrigation PlansSYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 8` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 10` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 12` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 15` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 17` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV ADJUSTABLE ARC TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS HUNTER I-20-06-SS-R 2.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 2 34' HUNTER I-20-06-SS-R 3.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 3 38' HUNTER I-20-06-SS-R 4.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 4 40' HUNTER I-20-06-SS-R 5.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 5 42' HUNTER I-20-06-SS-R 6.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 6 43' HUNTER I-20-06-SS-R 8.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN NATIVE SEED AREAS SHALL BE PLASTIC RISERS 45 8 44' HUNTER PGJ-06-R 1.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK VALVE. 40 1 19' HUNTER PGJ-06-R 2.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK VALVE. 40 2 25' HUNTER PGJ-06-R 3.0 TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK VALVE. 40 3 31' IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL DRIP VALVE ASSEMBLY RAIN BIRD XCZ-100-PRB-COM: WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM PIPE TRANSITION POINT IN DRIP BOX PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP TUBING WITH RISER IN 6" (150MM) DRIP BOX. DRIP FLUSH VALVE 3/4" SCH 40 OR SCH 80 PVC BALL VALVE PER DETAILS SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G-FS-R: 1", 1-1/2", AND 2" PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY AND PURPLE HANDLE QUICK COUPING VALVE ASSEMBLY RAIN BIRD 44-NP: 1IN. BRASS QUICK-COUPLING VALVE, WITH CORROSION-RESISTANT STAINLESS STEEL SPRING, LOCKING NON-POTABLE PURPLE RUBBER COVER, AND 2-PIECE BODY. ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. NORMALLY CLOSED MASTER VALVE ASSEMBLY SUPERIOR 3000: NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION AND 3-WAY SOLENOID DESIGN. SIZED PER POC (1" SMALLEST) PEDESTAL MOUNT 2-WIRE CONTROLLER HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INSTALL WITH WIRELESS RAIN SENSOR SOLAR SYNC. INSTALL CENTRALUS CELLULAR CARD A2C-LTEM. COORDINATE WITH GENERAL CONTRACTOR AND OWNER ON MONTHLY SERVICE CREATIVE SENSOR TECHNOLOGY FSI-T 1", 1.5", OR 2" (SIZE TO MATCH POC) PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT COMPATIBLE W/ALL IRRIGATION CONTROLLERS. FLOW RANGE: .86-52 GPM. 1.5" SIZE FLOW RANGE 1.8-108 GPM. 2" SIZE FLOW RANGE 2.8-170 GPM. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 X-INCH UNLESS OTHERWISE NOTED (GASKETED PIPE AND DUCTILE IRON FITTINGS FOR PIPING 3" OR LARGER PER SPECIFICATIONS) PIPE SLEEVE: PVC SCHEDULE 40 INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL SHARE THE SAME SLEEVE. A Valve Number Valve Flow Valve Size Valve Callout # ##" INSTALLATION GENERAL NOTES 1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION SYSTEM (PER ENGINEER ) OF 90 PSI, AT A MAXIMUM PEAK FLOW OF 80 GPM AT THE EXISTING NON-POTABLE 6-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 1.1.IRRIGATION TAP, METER, SERVICE LINES, AND BACKFLOW SHALL ALL BE THE SAME SIZE, AS STATED ABOVE. 1.2.IRRIGATION IS CONNECTED DOWNSTREAM OF THE 6-INCH NON-POTABLE LINE AS INDICATED. IRRIGATION IS DESIGNED TO UTILIZE ONLY 80 GPM FROM THE 2-INCH METER, BY OTHERS. 1.2.1.AVAILABLE PUMP STATION PRESSURE OBTAINED IS 90 PSI AT ELEVATION 4890'. 2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL SPRINKLERS MAY BE REQUIRED. 8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN WITHIN THE 3'-5' RANGE NOTED ABOVE. 9.NON-POTABLE WATER IS BEING UTILIZED ON THIS SITE. INSTALL ALL MAINLINE PIPE WITH CHRISTY ID WARNING TAPE READING "NON-POTABLE WATER, DO NOT DRINK". INSTALL AT LEAST 6" ABOVE MAINLINE PIPE. 9.1.SCRUBBER VALVES SHALL BE INSTALLED PER DETAILS. 9.2.PURPLE HANDLES ON ALL VALVES SHALL BE INSTALLED PER DETAILS. 9.3.NON-POTABLE WARNING SIGNS SHALL BE POSTED ON SITE HEAR GATHERING PLACES. INSTALL PER COLORADO HEALTH CODES. 9.4.BACKFLOW PREVENTOR IS NOT NECESSARY. 10. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 11.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 12.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 13.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 14.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 14.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 15.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 15.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS 16.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 17.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 18.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 19.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. 20.CONTRACTOR SHALL PROVIDE SMART CONTROLLER CHART, PER LOCAL WATER DISTRICT OR MUNICIPALITY, INSIDE CONTROLLER DOOR. EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. 3.REFER TO PROVIDED LANDSCAPE PLANS FOR PLANT TYPES AND SIZES. INSTALL EMITTERS PER PLANT WATER REQUIREMENT. CODE DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE NON-POTABLE IRRIGATION WATER TAP AND METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR EXACT LOCATION). INSTALL ISOLATION GATE VALVE, QUICK COUPLER, MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED OUTSIDE OF EASEMENTS. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTRACTOR SHALL VERIFY AVAILABLE FLOW AND PRESSURE PRIOR TO CONSTRUCTION. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE. IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE SLEEVED. 1 2 3 REFERENCE NOTES SCHEDULE SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR1.0 AND NOTES IRRIGATION LEGEND Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 2' ' W 2' ' W 2'' W T T T T T T T T UP UP UP UP 2' ' W 2' ' W 2'' W T T T T T T T T POC NO.1 EXISTING NON-POTABLE TAP SIZE: 6-INCH METER SIZE: 2-INCH PEAK DEMAND: 80 GPM AVAILABLE PRESSURE: 90 PSI CONTROLLER 'A' 120 VAC POWER REQUIRED A 1 2 SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR1.1 IRRIGATION PLAN Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MATCHLINE - SEE SHEET IR1.2 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 2'' W 2'' W 2'' W T T T T T T T UP UP UP UP 2'' W 2'' W 2'' W T T T T T T T 3 SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR1.2 IRRIGATION PLAN Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MATCHLINE - SEE SHEET IR1.1 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com MATCHLINE - SEE SHEET IR1.3 2' ' W 2'' W T T T T T T T T T 2' ' W 2'' W UP UP 2' ' W 2'' W T T T T T T T T T 2' ' W 2'' W SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR1.3 IRRIGATION PLAN Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com MATCHLINE - SEE SHEET IR1.2 MATCHLINE - SEE SHEET IR1.4 2'' W 2'' W 2'' W T T T T T T T UP UP UP UP 2'' W 2'' W 2'' W T T T T T T T SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR1.4 IRRIGATION PLAN Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com MATCHLINE - SEE SHEET IR1.3 SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR2.1 IRRIGATION DETAILS Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com MASTER VALVE ASSEMBLY1 ISOLATION GATE VALVE ASSEMBLY3 QUICK COUPLING VALVE ASSEMBLY4 REMOTE CONTROL TURF VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY SPRINKLER ASSEMBLY8 FLOW SENSOR ASSEMBLY2 TYPICAL THRUST BLOCK DETAIL10 PEDESTAL MOUNT CONTROLLER ASSEMBLY5 CAP (IPS) (PJ) 11.25° BEND (IPS) (PJ x PJ) TEE w/ REDUCER IN BRANCH & RUN (IPS) (PJ x PJ x PJ) FLANGE ADAPTER CONNECTION (IPS) PJ x FLG 45° BEND (IPS) (PJ x PJ) 22.5° BEND (IPS) (PJ x PJ) TEE (IPS) (PJ x PJ x PJ) 90° BEND (IPS) (PJ x PJ) REDUCER (IPS) (PJ x PJ) PIPE BELL PIPE FITTING WITH JOINT RESTRAINT11TYPICAL GROUNDING (AT VALVE) ASSEMBLY9 A SHEET TITLE: SHEET NO: PO Box 1889 FORT COLLINS, COLORADO 80522-1889 970.231.6749 T www.vignettestudios.com ACAD FILE: DRAWN: CHECKED: JOB NO: REVISIONS ISSUE DATE: CLIENT 40 March 12, 2025 --- -- MLP MLP - 25028 - - IR2.2 IRRIGATION DETAILS Bl o o m F I l i n g T h r e e FI N A L D E V E L O P M E N T P L A N S FO R T C O L L I N S , C O L O R A D O 0 10 20 SCALE 1"=20' MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com REMOTE CONTROL DRIP VALVE ASSEMBLY12 SINGLE OUTLET EMITTER ASSEMBLY13 TYPICAL TRENCHING DETAIL17 TYPICAL SLEEVING DETAIL16 24" min. INLINE DRIP PIPE ASSEMBLY FOR TREES IN NATIVE 15DRIP FLUSH CAP ASSEMBLY14