HomeMy WebLinkAboutBLOOM FILING THREE - FDP250003 - SUBMITTAL DOCUMENTS - ROUND 1 - Irrigation PlansSYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 8` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 10` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 12` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 15` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 17` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV ADJUSTABLE ARC
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS
HUNTER I-20-06-SS-R 2.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 2 34'
HUNTER I-20-06-SS-R 3.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 3 38'
HUNTER I-20-06-SS-R 4.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 4 40'
HUNTER I-20-06-SS-R 5.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 5 42'
HUNTER I-20-06-SS-R 6.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 6 43'
HUNTER I-20-06-SS-R 8.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE. WITH RECLAIMED WATER PURPLE ID. ROTORS IN
NATIVE SEED AREAS SHALL BE PLASTIC RISERS
45 8 44'
HUNTER PGJ-06-R 1.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK
VALVE.
40 1 19'
HUNTER PGJ-06-R 2.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK
VALVE.
40 2 25'
HUNTER PGJ-06-R 3.0
TURF ROTOR, 6IN. POP-UP. ADJUSTABLE AND FULL CIRCLE.
WITH RECLAIMED WATER PURPLE ID, AND DRAIN CHECK
VALVE.
40 3 31'
IRRIGATION SCHEDULE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL DRIP VALVE ASSEMBLY
RAIN BIRD XCZ-100-PRB-COM: WIDE FLOW DRIP CONTROL KIT
FOR COMMERCIAL APPLICATIONS. 1" BALL VALVE WITH 1"
PESB VALVE AND 1" PRESSURE REGULATING 40PSI
QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM
PIPE TRANSITION POINT IN DRIP BOX
PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP
TUBING WITH RISER IN 6" (150MM) DRIP BOX.
DRIP FLUSH VALVE
3/4" SCH 40 OR SCH 80 PVC BALL VALVE PER DETAILS
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER ICV-G-FS-R: 1", 1-1/2", AND 2" PLASTIC ELECTRIC
REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH
NPT THREADED INLET/OUTLET, FOR
COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY AND
PURPLE HANDLE
QUICK COUPING VALVE ASSEMBLY
RAIN BIRD 44-NP: 1IN. BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
LOCKING NON-POTABLE PURPLE RUBBER COVER, AND
2-PIECE BODY.
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL
PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE
AS MAINLINE PIPE.
NORMALLY CLOSED MASTER VALVE ASSEMBLY
SUPERIOR 3000: NORMALLY CLOSED BRASS MASTER VALVE
THAT PROVIDES DIRTY WATER PROTECTION AND 3-WAY
SOLENOID DESIGN. SIZED PER POC (1" SMALLEST)
PEDESTAL MOUNT 2-WIRE CONTROLLER
HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER
CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL.
INSTALL WITH WIRELESS RAIN SENSOR SOLAR SYNC.
INSTALL CENTRALUS CELLULAR CARD A2C-LTEM.
COORDINATE WITH GENERAL CONTRACTOR AND OWNER ON
MONTHLY SERVICE
CREATIVE SENSOR TECHNOLOGY FSI-T
1", 1.5", OR 2" (SIZE TO MATCH POC) PVC TEE TYPE FLOW
SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND
ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW
MEASUREMENT. 2 WIRE DIGITAL OUTPUT COMPATIBLE
W/ALL IRRIGATION CONTROLLERS. FLOW RANGE: .86-52
GPM. 1.5" SIZE FLOW RANGE 1.8-108 GPM. 2" SIZE FLOW
RANGE 2.8-170 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL
TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED
ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL
TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED
ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.
IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION
LATERAL LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE
PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER
CHART.
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
X-INCH UNLESS OTHERWISE NOTED (GASKETED PIPE AND
DUCTILE IRON FITTINGS FOR PIPING 3" OR LARGER PER
SPECIFICATIONS)
PIPE SLEEVE: PVC SCHEDULE 40
INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE
PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE
BUNDLES SHALL SHARE THE SAME SLEEVE.
A
Valve Number
Valve Flow
Valve Size
Valve Callout
#
##"
INSTALLATION GENERAL NOTES
1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION
SYSTEM (PER ENGINEER ) OF 90 PSI, AT A MAXIMUM PEAK FLOW OF 80 GPM AT THE
EXISTING NON-POTABLE 6-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND
FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S
REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE.
1.1.IRRIGATION TAP, METER, SERVICE LINES, AND BACKFLOW SHALL ALL BE THE SAME
SIZE, AS STATED ABOVE.
1.2.IRRIGATION IS CONNECTED DOWNSTREAM OF THE 6-INCH NON-POTABLE LINE AS
INDICATED. IRRIGATION IS DESIGNED TO UTILIZE ONLY 80 GPM FROM THE 2-INCH
METER, BY OTHERS.
1.2.1.AVAILABLE PUMP STATION PRESSURE OBTAINED IS 90 PSI AT ELEVATION 4890'.
2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE
POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK
SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.
3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE
INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP.
4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR
CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION.
4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND
BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE
VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS.
4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS
PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF
EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM,
ETC.
5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND
PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR
GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF
THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED
DESIGN, DETAILS, OR SPECIFICATIONS.
7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE
INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION
COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY.
8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND
ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION
OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO
SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL
SPRINKLERS MAY BE REQUIRED.
8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE
AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE
ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN
WITHIN THE 3'-5' RANGE NOTED ABOVE.
9.NON-POTABLE WATER IS BEING UTILIZED ON THIS SITE. INSTALL ALL MAINLINE PIPE
WITH CHRISTY ID WARNING TAPE READING "NON-POTABLE WATER, DO NOT DRINK".
INSTALL AT LEAST 6" ABOVE MAINLINE PIPE.
9.1.SCRUBBER VALVES SHALL BE INSTALLED PER DETAILS.
9.2.PURPLE HANDLES ON ALL VALVES SHALL BE INSTALLED PER DETAILS.
9.3.NON-POTABLE WARNING SIGNS SHALL BE POSTED ON SITE HEAR GATHERING
PLACES. INSTALL PER COLORADO HEALTH CODES.
9.4.BACKFLOW PREVENTOR IS NOT NECESSARY.
10. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.
11.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA
CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE
REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION
DESIGNER FOR APPROVAL.
12.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO
CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL
BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH
PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE
INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES
BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE
HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR.
13.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
14.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF
UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED
PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE
SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.
14.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG
IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND
MAY NOT BE THE LARGEST SIZE ON PLANS.
15.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE
ROUTED WITH MAINLINE.
15.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS
16.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR
TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS
ARE IRRIGATED ON DRIP SYSTEM.
17.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
18.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT
UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND
ESTABLISHMENT.
19.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES,
AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION.
20.CONTRACTOR SHALL PROVIDE SMART CONTROLLER CHART, PER LOCAL WATER
DISTRICT OR MUNICIPALITY, INSIDE CONTROLLER DOOR.
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A
NOTES:
1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS.
3.REFER TO PROVIDED LANDSCAPE PLANS FOR PLANT TYPES AND SIZES. INSTALL EMITTERS PER PLANT
WATER REQUIREMENT.
CODE DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE NON-POTABLE IRRIGATION WATER TAP
AND METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO
CIVIL PLANS FOR EXACT LOCATION). INSTALL ISOLATION GATE
VALVE, QUICK COUPLER, MASTER VALVE ASSEMBLY, AND FLOW
SENSOR AS INDICATED OUTSIDE OF EASEMENTS. VERIFY EXACT
LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY
PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION.
CONTRACTOR SHALL VERIFY AVAILABLE FLOW AND PRESSURE
PRIOR TO CONSTRUCTION.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE
FOR MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT
MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE
APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE
INSTALLED PER NATIONAL ELECTRIC CODE.
IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL
IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY
IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE
SLEEVED.
1
2
3
REFERENCE NOTES SCHEDULE
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR1.0
AND NOTES
IRRIGATION LEGEND
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
2'
'
W
2'
'
W
2'' W T
T
T
T
T
T
T
T
UP UP
UP
UP
2'
'
W
2'
'
W
2'' W T
T
T
T
T
T
T
T
POC NO.1
EXISTING NON-POTABLE TAP SIZE: 6-INCH
METER SIZE: 2-INCH
PEAK DEMAND: 80 GPM
AVAILABLE PRESSURE: 90 PSI
CONTROLLER 'A'
120 VAC POWER REQUIRED
A
1
2
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR1.1
IRRIGATION PLAN
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MATCHLINE - SEE SHEET IR1.2
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
2'' W
2'' W
2'' W
T
T
T
T
T
T
T
UP
UP
UP
UP
2'' W
2'' W
2'' W
T
T
T
T
T
T
T
3
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR1.2
IRRIGATION PLAN
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MATCHLINE - SEE SHEET IR1.1
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
MATCHLINE - SEE SHEET IR1.3
2'
'
W
2'' W
T
T
T
T
T
T
T
T
T
2'
'
W
2'' W
UP
UP
2'
'
W
2'' W
T
T
T
T
T
T
T
T
T
2'
'
W
2'' W
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR1.3
IRRIGATION PLAN
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
MATCHLINE - SEE SHEET IR1.2
MATCHLINE - SEE SHEET IR1.4
2'' W
2'' W
2'' W
T
T
T T
T
T
T
UP
UP
UP UP
2'' W
2'' W
2'' W
T
T
T T
T
T
T
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR1.4
IRRIGATION PLAN
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
MATCHLINE - SEE SHEET IR1.3
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR2.1
IRRIGATION DETAILS
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
MASTER VALVE
ASSEMBLY1 ISOLATION GATE VALVE
ASSEMBLY3 QUICK COUPLING VALVE
ASSEMBLY4
REMOTE CONTROL TURF
VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN
ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY
SPRINKLER ASSEMBLY8
FLOW SENSOR
ASSEMBLY2
TYPICAL THRUST BLOCK
DETAIL10
PEDESTAL MOUNT CONTROLLER
ASSEMBLY5
CAP (IPS)
(PJ)
11.25° BEND (IPS)
(PJ x PJ)
TEE w/ REDUCER
IN BRANCH & RUN
(IPS)
(PJ x PJ x PJ)
FLANGE ADAPTER
CONNECTION (IPS)
PJ x FLG
45° BEND (IPS)
(PJ x PJ)
22.5° BEND (IPS)
(PJ x PJ)
TEE (IPS)
(PJ x PJ x PJ)
90° BEND (IPS)
(PJ x PJ)
REDUCER (IPS)
(PJ x PJ)
PIPE BELL
PIPE FITTING WITH JOINT
RESTRAINT11TYPICAL GROUNDING (AT VALVE)
ASSEMBLY9
A
SHEET TITLE:
SHEET NO:
PO Box 1889
FORT COLLINS, COLORADO
80522-1889
970.231.6749 T
www.vignettestudios.com
ACAD FILE:
DRAWN:
CHECKED:
JOB NO:
REVISIONS
ISSUE DATE:
CLIENT
40
March 12, 2025
---
--
MLP
MLP
-
25028
-
-
IR2.2
IRRIGATION DETAILS
Bl
o
o
m
F
I
l
i
n
g
T
h
r
e
e
FI
N
A
L
D
E
V
E
L
O
P
M
E
N
T
P
L
A
N
S
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
0 10 20
SCALE 1"=20'
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
REMOTE CONTROL DRIP
VALVE ASSEMBLY12 SINGLE OUTLET EMITTER
ASSEMBLY13
TYPICAL TRENCHING
DETAIL17
TYPICAL SLEEVING
DETAIL16
24" min.
INLINE DRIP PIPE ASSEMBLY
FOR TREES IN NATIVE 15DRIP FLUSH CAP