HomeMy WebLinkAboutPlans - Site Plan - 12/10/2024G-1
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Cover
Sheet
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
SE PERSPECTIVE VIEW
NO SCALE
SW PERSPECTIVE VIEW
NO SCALE
Residential Single Unit with Attached Accessory Dwelling Unit
LEGAL ADDRESS: LOT B, LONGSTEIN SUBDIVISION, FORT COLLINS, CO
PARCEL NUMBER: 9711240002
GENERAL NOTES:
1.REFER TO STRUCTURAL DRAWINGS FOR
FOUNDATION, FRAMING AND ROOF DETAILS.
2.THESE DRAWINGS ARE FOR THE BUILDER AND ALL
DIMENSIONS SHOULD BE CONFIRMED PRIOR TO
CONSTRUCTION.
3.THE BUILDER/CONTRACTOR AND
SUBCONTRACTORS SHALL CONFORM TO ALL
APPLICABLE BUILDING CODES.
4.THE CONTRACTOR SHALL PROVIDE MECHANICAL
AND ELECTRICAL ENGINEERING AS REQUIRED TO
COMPLETE WORK AND FOR INTENDED PURPOSE.
MECHANICAL CONTRACTOR SHALL VERIFY
DIMENSIONS OF ALL NECESSARY DUCTS WORK
AND EQUIPMENT AND NOTIFY KATY ENGINEERING
IF CHANGES ARE REQUIRED.
SITE NOTES:
1.BUILDER SHALL PROVIDE POSITIVE DRAINAGE
AWAY FROM STRUCTURE AND ACROSS SITE PER
CIVIL ENGINEERING DRAINAGE AND SITE PLAN.
2.TOTAL FINISHED SQUARE FOOTAGE= 2,094 SF
(EXCLUDES GARAGE)
BASEMENT = 866 SF
MAIN FLOOR = 760 SF
SECOND FLOOR = 468 SF
GARAGE SQUARE FOOTAGE= 302 SF
3.TOTAL LOT AREA = 3,850 SF
ZONING INFORMATION:
OT-B - OLD TOWN DISTRICT, MEDIUM
Sheet Index
Sheet #Title
G-1 Cover Sheet
C-1 Site Plan
C-2 Existing Site Condtions
C-3 Parking Plan
A-1 Elevation Views
A-4 Section Views
PROJECT LOCATION
NO SCALE
IS
S
U
E
D
F
O
R
RE
V
I
E
W
PLANNING CERTIFICATE
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT
AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT
COLLINS, COLORADO ON THIS DAY, ________________
_______________________________________________
DIRECTOR'S SIGNATURE
OWNER'S CERTIFICATE
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE
THE LAWFUL OWNERS OF REAL PROPERTY DESCRIBED ON
THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT
THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID
PROJECT DEVELOPMENT PLAN WITHIN THE LIMIT OF
DEVELOPMENT BOUNDARY.
_______________________________ __________________
OWNER (SIGNED) DATE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE
ME ON THIS DAY,_____________.
BY:____________________________________________________
(PRINT NAME)
AS____________________________________________________
MY COMMISSION EXPIRES________________________________
WITNESS MY HAND AND OFFICIAL SEAL.
______________________________ ____________________
NOTARY PUBLIC ADDRESS
C-1
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Site Plan
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
IS
S
U
E
D
F
O
R
RE
V
I
E
W
C-2
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Existing Site
Condtions
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
IS
S
U
E
D
F
O
R
RE
V
I
E
W
C-3
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Parking
Plan
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
IS
S
U
E
D
F
O
R
RE
V
I
E
W
BOTTOM OF FOOTING
-6.2'
TOP OF GARAGE SLAB/FINISHED GRADE
-1.5'
4'-8"
TOP OF 1ST FLOOR
0'
1'-6"
TOP OF 2ND FLOOR
8.6'
8'-7 1/4"
TOP OF PLATE - 2ND FLOOR
16.9'
8'-3 9/16"
HIGHEST RIDGE
24.5'
7'-7 3/16"
BOTTOM OF FOOTING
-6.2'
TOP OF GARAGE SLAB/FINISHED GRADE
-1.5'
4'-8"
TOP OF 1ST FLOOR
0'
1'-6"
TOP OF 2ND FLOOR
8.6'
8'-7 1/4"
TOP OF PLATE - 2ND FLOOR
16.9'
8'-3 9/16"
HIGHEST RIDGE
24.5'
7'-7 3/16"
TOP OF BASEMENT SLAB
-9.7'
TOP OF 1ST FLOOR
0'
9'-8 5/8"
TOP OF PLATE
7.5'
7'-6 1/2"
RIDGE
18.1'
10'-7 1/8"
HIGHEST RIDGE
24.5'
6'-4 3/8"
26' MAX
1'-6" MIN
FINISHED GRADE
TOP OF BASEMENT SLAB
-9.7'
TOP OF 1ST FLOOR
0'
9'-8 5/8"
TOP OF PLATE
7.5'
7'-6 1/2"
RIDGE
18.1'
10'-7 1/8"
HIGHEST RIDGE
24.5'
6'-4 3/8"
26' MAX
1'-6" MIN
FINISHED GRADE
A-1
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Elevation
Views
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
WEST WALL ELEVATION
1/4"=1'
EAST WALL ELEVATION
1/4"=1'
IS
S
U
E
D
F
O
R
RE
V
I
E
W
SIDING: CLAPBOARD - COLOR: BENJAMIN MOORE WHITE
BLUE POLO 2062-10
SIDING: SHAKE SHINGLE - COLOR: BENJAMIN MOORE
WHITE DIAMOND 2121-60
STUCCO: MEDIUM FINISH - COLOR: BENJAMIN MOORE
WHITE DIAMOND 2121-60
BELLY BOARD: 1" X 12" HIGH CEDAR PAINTED - COLOR:
BENJAMIN MOORE WHITE DIAMOND 2121-60
ROOF MATERIAL: ASPHALT SHINGLE - BLACK
WINDOW/PATIO DOORS: ANDERSON 100 SERIES
WINDOWS AND DOORS - COLOR: WHITE
HUMAN DOOR: DOOR STYLE AND MANUFACTURER TO BE
DETERMINED BY OWNER - COLOR: BENJAMIN MOORE
WHITE DIAMOND 2121-60
SOFFIT/FASCIA: ENGINEERED WOOD - COLOR: BENJAMIN
MOORE WHITE DIAMOND 2121-60
GARAGE DOOR: DOOR STYLE AND MANUFACTURER TO BE
DETERMINED BY OWNER - COLOR: BENJAMIN MOORE
WHITE DIAMOND 2121-60
DECORATIVE CORBEL: COORDINATE WITH OWNER ON
PATTERN - COLOR: BENJAMIN MOORE WHITE DIAMOND
2121-60
RAILING: PER STRUCTURAL DRAWINGS, SHALL BE METAL
POWDER COATED BLACK.
PORCH AND STEPS: STAIR TREADS AND PORCH DECKING
TO BE TREX (OR EQUAL), COLOR: GRAY, POSTS AND
VERTICAL FRAMING TO BE WHITEWASHED WOOD STAIN.
RAILING PER STRUCTURAL SHALL BE METAL POWDER
COATED BLACK.
AA
BB
CC
DD
EE
FF
GG
EXTERIOR MATERIALS:
ALL MATERIALS INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS
HH
II
JJ
KK
LL
NORTH WALL ELEVATION
1/4"=1'
SOUTH WALL ELEVATION
1/4"=1'
AA
AA
AA
AA
BB
BB
BB
CC
CC CC
CC CC
DD
DD
DD
DD
DDDD
EE
EE
EEEE
EE
EE
FFFF
FF FF
FF
FF FF FF
FF
GG
GG
HHHHHHHH
HH HHHH
II
JJ
JJ
JJ
KKKKKK
KK KK
KK
LL
LL LL
13'-1 1/2"
TOP OF BASEMENT SLAB
-9.7'
TOP OF 1ST FLOOR
0'
9'-8 5/8"
TOP PLATE
11.4'
11'-4 15/16"
TOP OF WALL FINISH
18'
6'-7 1/2"
13'-1 1/2"
TOP OF BASEMENT SLAB
-9.7'
TOP OF 1ST FLOOR
0'
9'-8 5/8"
TOP PLATE
11.4'
11'-4 15/16"
TOP OF WALL FINISH
18'
6'-7 1/2"
BOTTOM OF FOOTING
-6.2'
TOP OF GARAGE SLAB/FINISHED GRADE
-1.5'
4'-8"
ROUGH CEILING - 1ST FLOOR
7.6'
9'-0 5/8"
TOP OF 2ND FLOOR
8.6'
1'-0 5/8"
TOP PLATE - 2ND FLOOR
15.6'
7'
RIDGE
24.5'
8'-10 3/4"
11'-0 5/8"
BOTTOM OF FOOTING
-6.2'
TOP OF GARAGE SLAB/FINISHED GRADE
-1.5'
4'-8"
ROUGH CEILING - 1ST FLOOR
7.6'
9'-0 5/8"
TOP OF 2ND FLOOR
8.6'
1'-0 5/8"
TOP PLATE - 2ND FLOOR
15.6'
7'
RIDGE
24.5'
8'-10 3/4"
11'-0 5/8"
A-4
SHEET NUMBER
PROJECT NUMBER
DATE
12/10/24
Section
Views
PR
O
J
E
C
T
I
N
F
O
R
M
A
T
I
O
N
:
Lo
n
g
s
t
e
i
n
S
u
b
d
i
v
i
s
i
o
n
72
8
C
h
e
r
r
y
S
t
r
e
e
t
L
o
t
B
Fo
r
t
C
o
l
l
i
n
s
,
C
O
240603
Revision Table
Number
Date
Revised By
Description
E5 - HOUSE SECTION
1/4"=1'
E7 - GARAGE SECTION
1/4"=1'
IS
S
U
E
D
F
O
R
RE
V
I
E
W
Windows: U-factor no greater than 0.28 and a solar heat gain
coefficient of 0.35 max.
Roof: Provide R-60 blown in insulation w/ rigid foam baffles at
heels of trusses, ventilate these areas
Exterior Walls: Provide R-30 insulation
ADU Floor: R-38 kraft-faced insulation in floors over
unheated spaces
Basement Walls: Provide R-15 insulation on interior of walls
Basement Floor: Provide R-10 rigid insulation under slab
Garage Exterior Walls: Provide R-15 insulation
Stem Walls: Provide R-15 insulation on interior of walls
12 4
6
MAIN LEVEL HOUSE
BASEMENT
11
22
33
44
55
66
77
88
NOTES:
1.Insulation values below meet the 2021 International Energy
Conservation code. Climate zone 5 insulation per 2021 IRC for
Single-Family prescriptive values.
2.Provide sound attenuation batts between all floor and ceilings at
main house and basement.
3.Provide expanding foam around all exterior window and door
installation and any other location too small for batt insulation.
4.Trusses to be scissor trusses and designed by a truss engineer and
have a 12" energy heel.
5.Walls to be 2x6 Construction, U.N.O. Floor joists, headers and
beams per structural drawings.
6.15/32" OSB or plywood over trusses.
7.1/2" gyp board typical on interior walls and ceilings.
TYPICAL INSULATION VALUES:
SECOND
FLOOR (ADU)
GARAGE
12 4
12
6
2x4 FRAMING ON
INTERIOR BASEMENT
WALL WITH 1/2" GYP
BOARD
12