No preview available
HomeMy WebLinkAboutTAPESTRY - FDP240016 - SUBMITTAL DOCUMENTS - ROUND 2 - Irrigation PlansIRRIGATION LEGEND MAINLINE: SCH. 40 PVC : 1.25" SPRINKLER LATERAL: CL200 PVC : 1" UNLESS INDICATED OTHERWISE DRIP TUBING: LLDPE DRIP TUBING-CENTENNIAL : 0.75" SLEEVING: CL200 PVC : 2XNOMINAL SIZE OF CONTAINED PIPE OR WIRE BUNDLE POINT OF CONNECTION/BACKFLOW ASSEMBLY ISOLATION GATE VALVE REMOTE CONTROL VALVE: RAIND BIRD PEB-PRSD SIZE AS SHOWN DRIP REMOTE CONTROL VALVE: RAIN BIRD XCZ-100-PRB-COM A IRRIGATION CONTROLLER: BASELINE BASESTATION 3200 CONTROLLER AND STATION NUMBER FLOW (GPM) NOMINAL VALVE SIZE 17 43 1" A HUNTER I-20-06: 55 PSI NOZZLE 2: 2.1 GPM, 34.0' NOZZLE 3: 3.4 GPM, 39.0' NOZZLE 4: 4.5 GPM, 41.0' NOZZLE 5: 5.7 GPM, 42.0' HUNTER PRO SPRAY PROS-06-PRS30-CV: 30 PSI STRIP SS-918: 1.7 GPM, 9'x18' RADIUS 8', FLOW (GPM): Q-0.2, H-0.5 RADIUS 10', FLOW (GPM): Q-0.4, H-0.9 RADIUS 12', FLOW (GPM): Q-0.7 RADIUS 15', FLOW (GPM): Q-1.0, H-1.9 RADIUS 17', FLOW (GPM): Q-1.2, H-2.4 MASTER VALVE/FLOW SENSOR ASSEMBLY QUICK COUPLER: RAIN BIRD 44-RC DRIP FLUSH CAP 2 3 4 5 9SS QC MV POC Sheet Sheet Name Checked By: Drawn By: Date: REV.COMMENT DATE TG AL 1.21.2025 TA P E S T R Y IR-0 IRRIGATION COVER SHEET CITY OF FORT COLLINS NOTES 1.ANY FIELD ADJUSTMENT OR REDESIGN OF THIS IRRIGATION SYSTEM MUST CONFORM TO THE CITY OF FORT COLLINS IRRIGATION STANDARDS IN THE LAND USE CODE 3.2.1(J)(3). 2.CONTRACTOR INSTALLING THE SYSTEM MUST PROVIDE FCU AND THE OWNER WITH “AS-BUILT” DRAWINGS AFTER INSTALLATION IS COMPLETE, INCLUDING UPDATED CHARTS WITH EXISTING FIELD CONDITIONS. 3.THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 80 PSI, AT A MINIMUM DISCHARGE OF 21 GPM AT THE 1-INCH POINT-OF-CONNECTION. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 4.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 5.COORDINATE UTILITY LOCATES (“CALL BEFORE YOU DIG”) OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 6.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER’S REPRESENTATIVE. 7.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. 8.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS AND ARCHITECTURAL FEATURES. 9.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 10.PROVIDE TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES AND TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT AND REPAIR OF SPRINKLERS. 11.SELECT NOZZLES FOR SPRAYHEADS AND ROTORS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 14.WITHIN SIX (6) WEEKS OF THE INSTALLATION OF NEW LANDSCAPING, THE IRRIGATION SYSTEM INSTALLER SHALL RESET THE SMART CONTROLLERS TO THE NORMAL SEASONAL WATERING SCHEDULE. GENERAL NOTES 1.INSTALL SYSTEM TO IRRIGATE NEW LANDSCAPING. SPRINKLERS IRRIGATE SOD AREAS. DRIP WILL IRRIGATE NEW TREE AND SHRUB PLANTINGS.TEMPORARY SPRINKLER IRRIGATION HAS BEEN PROVIDED FOR ESTABLISHMENT OF NATIVE SEED AND GRASSES IN DETENTION AREAS. WATER SOURCE IS POTABLE IRRIGATION METER AT LOCATION INDICATED. 2.CONTROL WILL BE VIA NEW IRRIGATION CONTROLLER PEDESTAL MOUNTED ADJACENT TO BACKFLOW. CONTROL WILL BE VIA TWO WIRE PATH. INSTALL DECODERS AND GROUNDING PER MANUFACTURER'S RECOMMENDATION. INSTALL CONTROL CABLE NOT ADJACENT TO MAINLINE IN CONDUIT. 3.WARRANTY IRRIGATION SYSTEM FOR ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE OF WORK. 4.SLEEVING WILL BE INSTALLED BY THE IRRIGATION CONTRACTOR. SLEEVES ARE REQUIRED FOR BOTH PIPING AND CONTROL WIRING AT EACH HARDSCAPE CROSSING. SIZE SLEEVES TO BE TWICE THE SIZE OF THE PIPE OR WIRE BUNDLE THAT IS CARRIED IN SAID SLEEVE. 5.MAINLINE PIPE: a.USE SCH. 40 ASTM 1785 RIGID PVC PIPE. b.USE SOLVENT WELD PIPE. c.USE SCHEDULE 40, TYPE 1, PVC SOLVENT WELD FITTINGS. USE PRIMER APPROVED BY THE PIPE MANUFACTURER. d.MAINLINE PIPE IS 1.25" NOMINAL SIZE UNLESS INDICATED OTHERWISE. e.CONDUCT A MAINLINE PRESSURE TEST AT AVAILABLE PRESSURE OVER ONE HOUR, ALLOWABLE PRESSURE DROP IS 5 PSI. f.MAINLINE PIPE TO BE BURIED WITH 24-INCHES OF COVER. 10. LATERAL PIPE: a.USE CLASS 200 SDR 21 NSF APPROVED RIGID PVC PIPE b.USE SOLVENT WELD PIPE. c.USE SCHEDULE 40, TYPE 1, PVC SOLVENT WELD FITTINGS. USE PRIMER APPROVED BY THE PIPE MANUFACTURER. d.MINIMUM LATERAL PIPE SIZE IS 1". SIZE PIPE AS INDICATED. ALL SECTIONS OF PIPE BETWEEN TWO IDENTICAL LABELS ARE THE SIZE OF SAID LABELS. e.FLEXIBLE POLYETHYLENE PIPE RATED FOR AT LEAST 100 PSI FOR ALL PIPE 1-1/2” AND SMALLER LATERAL PIPE CAN BE USED. USE PLASTIC TYPE PVC OR NYLON INSERT FITTINGS AND SADDLE TEES. f.SPRINKLER LATERAL PIPE TO BE BURIED WITH 14-INCHES OF COVER. 11. DRIP TUBING: a.USE U.V. RESISTANT POLYETHYLENE RATED FOR 60 PSI. b.USE COMPRESSION FITTINGS PER MANUFACTURER RECOMMENDATION. c.DRIP TUBING TO BE BURIED WITH 4-INCHES OF COVER. 13. COMPACT TRENCHES IN 6-INCH LIFTS TO 90% PROCTOR DENSITY. PUDDLING OF TRENCHES IS NOT ALLOWED. 14. PROVIDE TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVE. 15. FURNISH ACCURATE REPRODUCIBLE “AS-BUILT” DRAWINGS SHOWING FIELD CHANGES IN LAYOUT AND EQUIPMENT INSTALLATION. AS-BUILT DRAWINGS TO BE PLOTTED OUT FULL SCALE ALSO INCLUDE AN ELECTRONIC COPIES IN AUTOCAD AND ADOBE ACROBAT (PDF) FORMAT. 16. CLEAN UP ALL DEBRIS RELATED TO THE JOB, AND LEAVE THE SITE IN A CLEAN TIDY CONDITION. 17. TEST AND DEMONSTRATE TO THE OWNER'S REPRESENTATIVE THE SATISFACTORY OPERATION OF THE SYSTEM. VAULT CABLE W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W E E E E E E E E E E E X X X W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W E E E E E E E E E E E X X X HYD X X X X X X X X X X 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W E E E E E E E E E E E E E E E E E E E E E E E E E E E E E EEEEEEEEEE E E E E E E E E E E E E E E E FOFOFOFOFOFOFOFOFOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E UD UD E E E E E E E E E UD UD UD UD DUCTILE IRON NYLOPLAST DUCTILE IRON NYLOPLAST DUCTILE IRON NYLOPLAST S S S S S SS S W F F WW F F W F W F W W W F / / / / / / / / 9'-11" 2 4 3 13 3 2 4 3 1 1 1-INCH IRRIGATION METER AND BACKFLOW. MAX DESIGN DEMAND: 21 GPM @ 80 PSI. A A21 2.8 GPM 79.64 PSI A12 20.6 GPM 78.96 PSI A36 17.1 GPM 74.40 PSI A43 17.1 GPM 71.27 PSI A14 13.5 GPM 78.42 PSI A13 20.3 GPM 76.70 PSI A16 15.8 GPM 74.31 PSI 11 19 1" A 17 18 1" A 21 17 1" A 20 10 1" A 19 11 1" A 21 12 1" A 19 3 1" A 19 4 1" A 18 5 1" A 14 15 1" A 16 16 1" A 20 13 1" A 14 14 1" A 11 9 1" A 13 6 1" A 13 2 1" A 19 1 1" A 4.1 25 1" A 2.6 24 1" A 2.0 23 1" A 2.9 21 1" A 2.4 22 1" A 3.1 35 1" A 1.3 34 1" A 2.9 33 1" A 2.4 32 1" A 2.6 31 1" A 2.3 30 1" A 3.8 29 1" A 2.7 28 1" A 1.9 27 1" A 2.0 26 1" A 4.0 20 1" A 14 8 1" A 14 7 1" A 17 37 1" A 17 38 1" A 17 39 1" A 17 40 1" A 17 41 1" A 17 36 1" A 17 42 1" A 17 43 1" A 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 5 5 9S S 9S S 9S S 9S S 9S S 9S S 44 4 4 4 4 4 4 3 3 3 3 3 3 3 4 4 4 4 4 4 2 2 4 5555 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 9S S 5 QC QC QC QC QC QC MV POC LOGAN AVENUE 4T H S T R E E T BUCKINGHAM STREETIRRIGATION LEGEND MAINLINE: SCH. 40 PVC : 1.25" SPRINKLER LATERAL: CL200 PVC : 1" UNLESS INDICATED OTHERWISE DRIP TUBING: LLDPE DRIP TUBING-CENTENNIAL : 0.75" SLEEVING: CL200 PVC : 2XNOMINAL SIZE OF CONTAINED PIPE OR WIRE BUNDLE POINT OF CONNECTION/BACKFLOW ASSEMBLY ISOLATION GATE VALVE REMOTE CONTROL VALVE: RAIND BIRD PEB-PRSD SIZE AS SHOWN DRIP REMOTE CONTROL VALVE: RAIN BIRD XCZ-100-PRB-COM A IRRIGATION CONTROLLER: BASELINE BASESTATION 3200 CONTROLLER AND STATION NUMBER FLOW (GPM) NOMINAL VALVE SIZE 17 43 1" A HUNTER I-20-06: 55 PSI NOZZLE 2: 2.1 GPM, 34.0' NOZZLE 3: 3.4 GPM, 39.0' NOZZLE 4: 4.5 GPM, 41.0' NOZZLE 5: 5.7 GPM, 42.0' HUNTER PRO SPRAY PROS-06-PRS30-CV: 30 PSI STRIP SS-918: 1.7 GPM, 9'x18' RADIUS 8', FLOW (GPM): Q-0.2, H-0.5 RADIUS 10', FLOW (GPM): Q-0.4, H-0.9 RADIUS 12', FLOW (GPM): Q-0.7 RADIUS 15', FLOW (GPM): Q-1.0, H-1.9 RADIUS 17', FLOW (GPM): Q-1.2, H-2.4 MASTER VALVE/FLOW SENSOR ASSEMBLY QUICK COUPLER: RAIN BIRD 44-RC DRIP FLUSH CAP 2 3 4 5 9SS QC MV POC Sheet Sheet Name Checked By: Drawn By: Date: REV.COMMENT DATE TG AL 1.21.2025 TA P E S T R Y SCALE MUST MEASURE 1 INCH OR DRAWING IS NOT TO SCALE. 0'40'20'80'120' 1" = 40' IR-1 IRRIGATION PLAN Sheet Sheet Name Checked By: Drawn By: Date: REV.COMMENT DATE TG AL 1.21.2025 TA P E S T R Y IR-2 IRRIGATION DETAILS NOTE: 1.FURNISH FITTINGS, PIPE AND BACKFLOW SIZED IDENTICALLY WITH NOMINAL IRRIGATION TAP SIZE. [J] [K] [L] [M] [N] [P] [Q] [R] [O] 4' MIN. COVER 12" MIN. [A] [G] [H] [E] [F] [D] [B][C] [I] [A]COPPER TEE WITH 3/4 -INCH RISER AND QUICK COUPLER [B]STANDARD IRRIGATION VALVE BOX [C]FINISH GRADE/TOP OF MULCH [D]6-INCH PVC CL 200 PIPE (LENGTH AS REQUIRED) [E]THREADED BRONZE GATE VALVE WITH SOLID WEDGE NON-RISING STEM [F]BRICK (1 OF 4) [G]COPPER MALE ADAPTER [H]TYPE K COPPER MAINLINE FROM WATER METER [I]TYPE K COPPER TO BACKFLOW [J]BACKFLOW PREVENTER ENCLOSURE: LE MEUR SINGLE SWING HINGE OR EQUAL [K]REDUCED PRESSURE BACKFLOW PREVENTION DEVICE WITH FULL PORT BRONZE BALL VALVES. SAME SIZE AS TAP [L]3/4 -INCH COPPER NIPPLE WITH CAP [M]CL200 PVC PIPE SLEEVE (1 OF 2) [N]4-INCH THICK CONCRETE PAD [O]TYPE K COPPER PIPE (TYPICAL) (LENGTH AS REQUIRED) [P]COPPER FEMALE ADAPTER [Q]SCH 40 PVC MALE ADAPTER [R]PVC MAINLINE [S]COPPER PIPE FROM WINTERIZATION ASSEMBLY NOTE: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. [A]FINISH GRADE/TOP OF MULCH [B]VALVE BOX WITH COVER: 10-INCH DIAMETER AROUND [C]6-INCH PVC CL200 PIPE (LENGTH AS REQUIRED) [D]BRICK (1 OF 2) [E]THREADED BRONZE GATE VALVE WITH SOLID WEDGE, NON-RISING STEM [F]PVC SCH40 OR WROT COPPER MALE ADAPTER (1 OF 2) [G]PVC MAINLINE [A] [B] [C] [D] [E] [F][G] NOTE: 1. FURNISH FITTINGS AND PIPING SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. [A]FINISH GRADE/TOP OF MULCH [B]QUICK COUPLING VALVE: AS SHOWN IN LEGEND [C]VALVE BOX: 10-INCH ROUND [D]PVC SCH80 NIPPLE (LENGTH AS REQUIRED) [E]BRICK (1 OF 2) [F]PREFABRICATED SWING JOIN WITH O-RING (1-INCH SIZE) [G]SCH40 SERVICE TEE [H]PVC MAINLINE [I]2-INCH X 2-INCH REDWOOD STAKE WITH STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT SUPPORT INTO UNDISTURBED SOIL [A] [B] [C] [D] [E] [F] [G] [H] [I] 3" MIN. [A]ID TAG [B]WATER PROOF CONNECTORS (4) [C]DECODER [D]REMOTE CONTROL VALVE (AS SHOWN IN LEGEND) [E]FINISH GRADE/TOP OF MULCH [F]PVC SCH 80 NIPPLE (CLOSE) [G]CONTROL CABLE: 30-INCHES IN VALVE BOX [H]STANDARD VALVE BOX WITH NON LOCKING COVER [I]PVC SCH 40 ELL [J]PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) [K]BRICK (1 OF 4) [L]SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND SCH 40 ELL [M]PVC MAINLINE PIPE [N]PVC SCH 40 TEE OR ELL [O]PVC BALL VALVE: SAME SIZE AS RCV [P]3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL [Q]SCH 40 MALE ADAPTER [R]PVC LATERAL PIPE [A] [B][C] [D] [E] [F] [G] [H] [I] [J] [K] [L][M] [N] [O][P][Q] [R] NOTE: FOR SPRINKLERS OVER 5 GPM USE PREFABRICATED PVC SWING JOINT [B] [A] [C] [D] [E] [A]FINISH GRADE [B]SPRINKLER HEAD: AS CALLED OUT IN LEGEND [C]SWING JOIN: 1/2-INCH FLEX TUBING WITH LASCO SWING JOINT FITTINGS [D]SERVICE TEE OR ELL [E]LATERAL PIPE 3" MIN. [I] [J] [A]DECODER [B]WATERPROOF CONNECTORS (4) [C]ID TAG [D]DRIP WYE STRAINER [E]REMOTE CONTROL VALVE: AS SHOWN IN LEGEND [F]FINISH GRADE [G]JUMBO VALVE BOX [H]SHC80 THREADED NIPPLE [I]SHC40 ELL [J]BRICK SUPPORTS (4) [K]3/4-INCH WASHED GRAVEL [L]MAINLINE [M]PE DRIP TUBING/PVC DRIP MANIFOLD [N]SCH 40 PVC BALL VALVE. [A][B] [C] [D] [E] [F] [G] [H] [K] [L] [M] [N] NOTE: 1.MAXIMUM LENGHT OF 1 4" DISTRIBUTION TUBING IS 5-FEET 2.STAKE ENDS OF DISTRIBUTION TUBING ON UPHILL SIDE OF PLANT. 3.DRIPLINE: USE RAIN BIRD XFS-CV-06-12 WITH 0.6 GPH EMITTERS SPACED AT 12-INCHES. [A]DECIDUOUS TREE (15 GPH): 25 FEET COIL DRIP LINE W/ 0.6 GPH EMMITERS SPACED 12" [B]CONIFEROUS TREE (12 GPH): 20 FEET COIL DRIP LINE W/ 0.6 GPH EMMITERS SPACED 12" [C]SHRUB PLANTINGS (2 GPH): 2 x XBCV-10PC EMITTER WITH 1/4-INCH DISTRIBUTION TUBING [D]GRASS/GROUNDCOVER PLANTINGS (1 GPH): 1 x XBCV-10PC EMITTER WITH 1/4-INCH DISTRIBUTION TUBING [E]POLYETHYLENE DRIP LATERAL [A] [B] [C] [E] [D] [A]FINISH GRADE/TOP OF MULCH [B]6-INCH ROUND VALVE BOX WITH COVER [C]FLUSH PLUG WITH HOSE THREAD CAP [D]DRIP IRRIGATION LATERAL [E]3-INCHES MIN. OF 3/4-INCH GRAVEL [F]BRICK (1 OF 2) [A] [B] [C] [D] [E] [F] 3 ISOLATION GATE VALVE ASSEMBLY 4 QUICK COUPLING VALVE ASSEMBLY 6 SPRINKLER ASSEMBLY5REMOTE CONTROL VALVE ASSEMBLY 7 DRIP REMOTE CONTROL VALVE ASSEMBLY 8 TYPICAL EMITTER PLACEMENT & SCHEDULE 9 DRIP FLUSH CAP ASSEMBLY 1 POINT OF CONNECTION/ BACKFLOW ASSEMBLY 3" MIN. MIN. 10X PIPE DIAMETER MIN. 5X PIPE DIAMETER [A]FLOMEC QS 200 FLOW SENSOR. TIP 45 DEG. [B]10-INCH ROUND VALVE BOX [C]SPARE WIRES [D]REMOTE CONTROL VALVE: SAME SIZE AS MAINLINE [E]ID TAG [F]FINISH GRADE/TOP OF MULCH [G]CONTROL WIRE [H]STANDARD VALVE BOX WITH COVER [I]PVC MAINLINE PIPE [J]BRICK (1 OF 4) [K]PVC SCH 40 MALE ADAPTER [L]3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL [A] [B][C] [D] [E] [F][G] [H] [I] [J][K] [L] 2 MASTER VALVE/ FLOW SENSOR ASSEMBLY