Loading...
HomeMy WebLinkAboutReports - Drainage - 11/01/2024 OVERALL DRAINAGE REPORT FOR STRAUSS LAKES CITY OF FORT COLLINS COUNTY OF LARIMER STATE OF COLORADO PREPARED FOR: Cottonwood Land and Farms, LLC PO Box 229 Boulder, CO 80306 PREPARED BY: Civil Resources, LLC 8308 Colorado Blvd. Suite 200 Firestone, Colorado 80504 CIVIL 111110LJRCESLLC PREPARED: NOVEMBER 2024 Overall Drainage Report Strauss Lakes Table of Contents Paqe 1.0 BACKGROUND.....................................................................................................................................................5 1.1 General Location...........................................................................................................................................5 1.2 Existing Site Information................................................................................................................................5 1.3 Floodplain Information...................................................................................................................................5 1.4 Master Drainage Basin Description...............................................................................................................6 1.5 Previous Studies...........................................................................................................................................7 1.6 Project Description........................................................................................................................................7 2.0 DRAINAGE DESIGN CRITERIA............................................................................................................................7 2.1 Regulations...................................................................................................................................................7 2.2 Hydrologic& Hydraulic Criteria.....................................................................................................................8 3.0 PROPOSED DRAINAGE FACILITIES...................................................................................................................8 3.1 General Concept...........................................................................................................................................8 3.2 Drainage System Outfall...............................................................................................................................9 3.3 Low Impact Development(LID)...................................................................................................................10 3.4 Municipal Separate Storm Sewer System (MS4) Permit.............................................................................11 3.5 Detention & Flood Control...........................................................................................................................11 4.0 CONCLUSIONS...................................................................................................................................................12 4.1 Compliance with Criteria.............................................................................................................................12 4.2 Drainage Concept.......................................................................................................................................12 5.0 REFERENCES ....................................................................................................................................................12 Prepared:November 2024 Page 2 of 13 Overall Drainage Report Strauss Lakes List of Appendices APPENDIX A FIGURES&TABLES Project Vicinity Map Hydrologic Soils Map & Table Effective Flood Insurance Rate Map Fort Collins Risk Map Fort Collins Stormwater Criterial Manual(select pages) APPENDIX B REFERENCE REPORTS Fox Meadows Basin Selected Plan— Water Quality Improvements Addendum to the Final Design Report for the Fossil Creek Reservoir Inlet Ditch Storm Water Overflow Memorandum:Hydraulic Analysis of Fossil Creek Reservoir Inlet Ditch Final Drainage and Erosion Control Report Rigden Farm—Filing Six APPENDIX C HYDROLOGIC& HYDRAULIC COMPUTATIONS East Horsetooth Road Historic Runoff Calculations Historic SWMM Model Preliminary Proposed SWMM Model WQCV Calculations Constructed Wetland Pond Calculations Modified FAA Calculations Hydraflow Express Output APPENDIX D DRAINAGE PLANS Historic Drainage Plan Proposed Drainage Plan Prepared:November 2024 Page 3 of 13 Overall Drainage Report Strauss Lakes ENGINEER'S CERTIFICATION OF DRAINAGE REPORT "I hereby certify that this report for the overall drainage design of Strauss Lakes was prepared by me(or under my direct supervision) in accordance with the provisions of the Fort Collins Stormwater Criteria Manual for the owners thereof." Registered Professional Engineer State of Colorado No.40551 Prepared:November 2024 Page 4 of 13 Overall Drainage Report Strauss Lakes 1.0 BACKGROUND 1.1 General Location The Strauss Lakes project is located northeast of the intersection of Ziegler Road and East Horsetooth Road, and is situated in Section 28, Township 7 North, Range 68 West of the 61h Principal Meridian, County of Larimer, State of Colorado. The project area includes parcel 8728000003, located within the City of Fort Collins, and parcel 8728000009, located in unincorporated Larimer County.The Site is bounded by Ziegler Road to the west, East Horsetooth Road to the south, Great Western Railway to the north, and the Boxelder Ditch to the northeast. Refer to Appendix A for a Project Vicinity Map. The purpose of this report is to accompany an annexation and PUD overlay application. The PUD establishes overall land uses for the property, but does not propose specific layouts or design. This report serves to establish the overall drainage objectives to be followed in future final drainage reports for each phase of development 1.2 Existin_p Site Information The Strauss Lakes project Site is currently undeveloped with native grass land cover. The property slopes west to east with grades generally ranging from 0.02%to 5.2%. Native,on-site soils can be classified as approximately 26%Hydrologic Soil Group B and 29%Group C and 45%Group D. Refer to Appendix A for soils map and classification table.A significant portion of the Site has been filled using material removed from a gravel pit located north of the Great Western Railroad. There are approximately 2.91 acres of existing wetlands and 12.42 acres of open water within the property boundary. Refer to the Ecological Characterization Study—Strauss Lakes Residential Development, prepared by ERO Resources Corporation. The Fossil Creek Reservoir Inlet Ditch (FCRID) traverses the Site, separating the City parcel (8728000003) from the unincorporated land (8728000009). FCRID conveys irrigation flows diverted from the Cache la Poudre River, as well as treated discharge from the Fort Collins wastewater treatment plant to the Fossil Creek Reservoir.A spill structure for the ditch is located along the south property line,just north of East Horsetooth Road.The spill structure is further described in section 1.4. There is flow in the FCRID year-round, and some waters are used to support regional oil and gas activities. The Boxelder Ditch is located within the north end of the Site and flows southeast along the eastern boundary of the Site. The Boxelder Ditch diverts irrigation flows from the Cache la Poudre River, and conveys flows to various on-site and off- site headgates downstream of the Site.A control structure for the ditch is located at the southeast corner of the Site. The Foothills Channel Outfall(FCO)runs along the southern property line of the unincorporated parcel(8728000009),just north of East Horsetooth Road. The FCO is an overflow channel for the FCRID, which conveys flows east along East Horsetooth Road and discharges to the Cache la Poudre River. The FCO is normally dry, and only has flows during significant wet weather events when the FCRID overflows to the FCO. There is a drainage ditch, Rigden Farm Outfall Channel (RFOC), located along the northern property line, between the railroad and existing access road.This ditch accepts discharge from the Rigden Farm water quality pond,located northeast of East Drake Road,and west of the FCRID. Flow in the outfall channel travels southwest and discharges to the Cache la Poudre River, east of Rigden Reservoir. 1.3 Floodplain Information A portion of the Site, southwest of the Boxelder Ditch, lies within Zone X, of the Cache La Poudre River, per Federal Emergency Management Agency(FEMA) Flood Insurance Rate Map (FIRM) number 08069C0992G.Zone X is defined as the area of 0.2%annual chance flood (500-year floodplain).A portion of the Site north of the Boxelder Ditch is located within Zone AE, the 1.0%annual chance flood (100-year floodplain).A copy of the effective FIRM is included in Prepared:November 2024 Page 5 of 13 Overall Drainage Report Strauss Lakes Appendix A. The floodplain in this area is currently being remapped by consultants for the Colorado Water Conservation Board and FEMA.A copy of the preliminary map (Fort Collins Risk Map) is included in Appendix A. The preliminary mapping indicates no portion of the Site will be located in the 100-year floodplain.The portion of the Site north of the Boxelder Ditch will be within the 500-year floodplain. This portion of the Site will need to be filled to elevate it out of the 500-year floodplain and to achieve more favorable drainage characteristics. 1.4 Master Drainage Basin Description A portion of the Site is located within the Cache La Poudre River Master Drainage Basin and the remaining portion is within the Fox Meadows Master Drainage Basin. The master drainage reports for both of these basins are in the process of being updated. 1.4.1 Cache La Poudre Master Drainage Basin The Cache La Poudre River Master Drainage Basin (Poudre Basin)was analyzed in the Cache La Poudre River Master Drainageway Plan, prepared by Ayres Associates in August 2001. This report discusses several problem drainage areas along the Cache la Poudre River, including sites upstream and downstream of the subject Site, but none directly impacting the Site. The Riverbend Ponds Area is located upstream of the subject Site, northwest of the City's wastewater treatment plant. The report identifies significant flooding and flood damage in this area. Several alternatives are presented in the report including the construction of levees, modification of existing levees, and the construction of a weir. These improvements have been completed. 1.4.2 Fox Meadows Drainage Basin The Fox Meadows Drainage Basin was evaluated in the following master reports: • Fox Meadows Basin Drainage Master Plan Update—50-Year Alt. Plan, prepared by ICON Engineering, Inc. on December 61h,2002. • Fox Meadows Basin Drainage Master Plan Update Phase A—Baseline Hydraulics and Problem Identification Report, prepared by ICON Engineering, Inc. and revised February 2003. • Fox Meadows Basin Drainage Master Plan Update Selected Plan Report, prepared by ICON Engineering, Inc. and revised February 2003. These reports state that much of the master basin has been developed,with little development potential remaining, and identifies several drainage problems within the master basin including overtopping detention ponds, insufficient freeboard of irrigation ditches and conveyance channels, and roadway overtopping.The subject Site is located on the upstream end of the master basin, and the problems identified in these reports occur downstream of the Site. Several mitigation efforts are proposed in the plans; however, it is unknown which, if any, of these solutions have been implemented. As indicated on the Fox Meadows Basin Selected Plan— Water Quality Improvements figure,the southwest corner of the Site(8728000003)was considered as an alternative location for a water quality pond to serve the Fox Meadows Drainage Basin (see Appendix B for referenced figure). The Strauss Lakes development does not accommodate a water quality pond to treat off-site flows. Prepared:November 2024 Page 6 of 13 Overall Drainage Report Strauss Lakes 1.5 Previous Studies The Site has been included in previous studies of the Fossil Creek Reservoir Inlet Ditch (FCRID),which traverses the Site. The Foothills Channel Outfall (FCO)was first described in the Final Design Report for the Fossil Creek Reservoir Inlet Ditch Storm Water Overflow prepared by Donohue&Associates, Inc. in February 1988.The FCO was designed to convey excess flows from the FCRID to the Cache la Poudre River. Flow is diverted from the FCRID via a spill structure located north of East Horsetooth Road. The FCO was initially designed to convey the total 100-year peak flow to the structure,which is 1,160 cfs.The Addendum to the Final Design Report for the Fossil Creek Reservoir Inlet Ditch Storm Water Overflow prepared by Donohue&Associates, Inc. in September 1988, limits this flow to 860 cfs,which means the control gate passes 300 cfs to the FCRID, south of East Horsetooth Road, during the 100-year peak storm. The flow in the FCO was most recently analyzed by Anderson Consulting Engineers, Inc. in the April 30, 2020 memorandum Hydraulic Analysis of Fossil Creek Reservoir Inlet Ditch Between Cache la Poudre River and Harmony Road for Future Strauss Lake Development. This study found that a maximum of 523 cfs flows through the FCO, downstream of the FCRID spill structure.This results in an available capacity of 337 cfs in the FCO at this location. The FCRID was also evaluated by Anderson Consulting Engineers, Inc. in the 2002 Hydraulic Analysis and Design of the Fossil Creek Reservoir Inlet Ditch Controlled Spill System. The information in this report is superseded by the 2020 memorandum. The design of the Rigden Farm Outfall Channel (RFOC)was detailed in the Final Drainage and Erosion Control Report Rigden Farm—Filing Six, prepared by JR Engineering, last revised February 8, 2002.The RFOC was previously a lateral of the Boxelder Ditch, and was repurposed to convey outflow from Pond 216 of the Rigden Farm development (located west of the FCRID, adjacent to the northern portion of the Site)to the Cache la Poudre River. Per the report, the 100-year discharge from the Pond 216 siphon outlet structure is 134 cfs, and the channel capacity is 178 cfs. See Appendix B for relevant excerpts of the abovementioned reports. 1.6 Proiect Description The Strauss Lakes Project proposes to develop the approximately 188-acre subject Site into a mixed-use neighborhood. The neighborhood will consist of both residential units(townhomes, single-family homes, paired homes, and multi-family homes)and commercial units(restaurant, retail, and neighborhood support services).This development will require both annexation of the unincorporated parcel (8728000009) into the City, and rezoning of the Site to a Planned Unit Development Overlay(PUD).The currently annexed parcel (8728000003) is zoned Low Density Mixed-Use Neighborhood District(LMN),which will be the basis of the PUD development characteristics. Related neighborhood infrastructure will include roadways, alleys, parks, trails,water quality improvements, on-and off-site utilities, local flood control/detention measures, access points off of Ziegler Road and East Horsetooth Road, and roadway improvements to East Horsetooth Road. The development Site is adjacent to the Rigden Farm, Dakota Ridge, and Stone Ridge developments, located west of Ziegler Road, Rigden reservoir to the east, Environmental Learning Center, Running Deer Natural Area, and Cache la Poudre River to the north, and Topminnow Natural Area and unincorporated residential homes to the south. 2.0 DRAINAGE DESIGN CRITERIA 2.1 Re_- ulations The proposed drainage design will comply with the regulations set forth in the Fort Collins Stormwater Criteria Manual (FCSCM), revised December 2018. Prepared:November 2024 Page 7 of 13 Overall Drainage Report Strauss Lakes 2.2 Hydrologic&Hydraulic Criteria The hydrology of the Site and the hydraulic of the stormwater system will be analyzed per the methods outlined in Chapter 5 of the FCSCM. The following methods will be presented in the final drainage report. • EPA Stormwater Management Model (SWMM) version 5.2 will be used to estimate the 2 and 100-year peak developed runoff as the minor and major storm events, respectively. The input parameters listed in Table 4.1-1 and the intensity-duration-frequency values from Table 4.1-4 of the FCSCM will be used to model the subcatchments and rain gauges. • Impervious values for the Site will be determined by land use for conceptual design, per Table 4.1-2 in the FCSCM, and will later be revised by surface type, per Table 4.1-3. • Inlets will be sized to capture the peak flow rate from the minor 2-year storm(minus the allowable street capacity), per chapter 12, section 1.4 of the FCSCM. • The water quality capture volume (WQCV)will be calculated per equations 7-1 and 7-2 in the FCSCM. • The on-site conveyance swale and emergency spillways will be sized using the Hydraflow Express extension for Autodesk Civil 3D. • The 100-year detention volumes will be determined using both the Modified FAA method, and EPA Stormwater Management Model(SWMM)version 5.2.The subcatchment input parameters for SWMM were taken from Table 4.1-1 in the FCSCM. 3.0 PROPOSED DRAINAGE FACILITIES 3.1 General Concept For the purposes of this Overall Drainage Report,the Site has been divided into the West Site, located west of the FCRID, the East Site, located east of the FCRID, and the North Site, located North of the Boxelder Ditch. Furthermore, the East Site has been subdivided into five(5)conceptual 20-acre drainage basins.The basin shapes are arbitrary, and not based on a specific road layout or grading scenario,but were developed to estimate runoff in order to conceptually size a drainage swale parallel to the Boxelder Ditch. The stormwater systems for the West Site, East Site, and North Site will function independently of one another. See Appendix D for the Overall Drainage Plan. 3.1.1 West Site The West Site will generally maintain the historic drainage pattern by directing flow northeast, via curb and gutter, inlets, and storm sewer. Captured runoff will be directed to a water quality pond located in teg eastern corner of the West Site. This pond will treat the WQCV of the West Site, and will not provide flood control.The flows greater than the WQCV will discharge east to the FCRID via a pipe and/or spillway. The 100-year flow will enter the FCO via the FCRID spill structure.The drainage area of the West Site is approximately 12.08 acres. The layout and density of the West Site is unknown at this point;therefore the impervious value of the West Site is conservatively assumed to be 90% (high density) per Table 4.1-2 of the FCSCM.The impervious value will be further refined in subsequent drainage reports using Table 4.1-3. The 100-year developed runoff of the West Site is estimated to be 118.88 cfs, per SWMM. See Appendix C for SWMM summary tables. 3.1.2 East Site The East Site currently drains east towards the Boxelder Ditch.The Boxelder intercepts minor storms, and major events either overtop the ditch and enter Rigden Reservoir, or enter the FCO. The proposed design will intercept runoff prior to Prepared:November 2024 Page 8 of 13 Overall Drainage Report Strauss Lakes entering the Boxelder Ditch. Each drainage basin will discharge to a conveyance swale located along the east property line,just west of the Boxelder Ditch.The conveyance swale will flow southeast to a constructed wetland pond (CWP), located at the southeast corner of the East Site. The swale was preliminarily sized for the cumulative flow from each of the five conceptual 20-acre basins,which resulted in a maximum top width of 62-feet.The Hydraflow Express analysis is included in Appendix C. The CWP will provide water quality treatment(further described in section 3.2)and flood control for the 100-year major storm event. Runoff from the major storm will be detained in the pond, and released to the Foothills Channel Outfall (FCO),via an outlet structure. There will be an emergency spillway located on the south side of the pond,which will be sized to pass the undetained 100-year runoff from the pond tributary area, per section 3.2 of the FCSCM.The spillway will discharge south to the FCO.The drainage area of the East Site is approximately 99.10 acres. The layout and density of the East Site is unknown at this point; therefore the impervious value of the East Site is conservatively assumed to be 90% (high density) per Table 4.1-2 of the FCSCM. The impervious value will be further refined in subsequent drainage reports using Table 4.1-3. The 100-year developed runoff of each subbasin of the East Site was calculated using SWMM to be 133.77 cfs,for a total runoff of 668.85 cfs. See Appendix C for SWMM summary tables. 3.1.3 North Site The North Site will maintain the historic drainage pattern by directing developed runoff east, via surface flow,curb and gutter, inlets, and storm sewer,to an extended detention basin (detention pond) located on the east side of the North Site. The pond will intercept the developed runoff and redirect it north, discharging to the Rigden Farm Outfall Channel. While the RFOC is not the historic discharge point of the North Site, redirecting the detained flow to the RFOC will reduce the amount of runoff flowing east to the future community park. The detention pond will be sized to treat the WQCV of the North Site, and temporarily store the 100-year developed runoff, releasing the detained flow at the allowable remaining capacity in the RFOC.This varies from the FCSCM requirement which limits developed runoff to the historic 2-year discharge for the Site. This variance from the standards is proposed because the detention pond will not be discharging to the historic discharge point(the adjacent property to the east), and the RFOC is a direct outfall to the Cache la Poudre River.The pond will have an emergency spillway located along the northeast side,which will be sized to pass the undetained 100-year runoff from the North Site,and discharge to the RFOC. The drainage area of the North Site is approximately 20 acres.The layout and density of the North Site is unknown at this point;therefore the impervious value of the North Site is conservatively assumed to be 90% (high density) per Table 4.1-2 of the FCSCM. The impervious value will be further refined in subsequent drainage reports using Table 4.1-3.The 100-year developed runoff of the North Site was estimated to be 127.26 cfs, per SWMM. See Appendix C for SWMM summary tables. 3.1.4 East Horsetooth Road The Site historically receives off-site flows from East Horsetooth Road,from the intersection with Ziegler Road to the FCRID crossing.The development of the Strauss Lakes Site will require improving the roadway to a two-lane arterial street, per Figure 7-3F of the Larimer County Urban Area Street Standards(LCUASS). Costs for this roadway construction will be shared by the City and the developer. For a Site frontage of approximately 2,950 linear feet,this results in an impervious area of 4.33 acres.The development will be responsible for providing water quality treatment of this new impervious area. The location of the FCO creates a barrier to treating the roadway runoff on-site;therefore, it is proposed to treat the runoff from East Horsetooth Road using an extended detention basin, located south of the road on City of Fort Collins property(parcel 8733231902).The detention pond will be sized for the WQCV and 100-year storage volume of the full-width roadway buildout,and will discharge to the FCO.The historic 2-year runoff of East Horsetooth Road was estimated to be 2.34 cfs per the Rational Method.The future impervious value of the roadway is assumed to be 95%, resulting in a 100-year developed runoff of approximately 43.44 cfs, per SWMM. See Appendix C for SWMM summary tables. Developed runoff will be captured in street inlets,and conveyed via storm sewer to the detention pond. 3.2 Drainage System Outfall Per prior agreements between Cottonwood Land and the City of Fort Collins, developed runoff from the West and East Prepared:November 2024 Page 9 of 13 Overall Drainage Report Strauss Lakes Sites, and East Horsetooth Road will be allowed to discharge to the Foothills Channel Outfall (FCO). As previously discussed,the FCO was most recently studied by Anderson Consulting Engineers, Inc. in a memorandum dated April 30, 2020.This study determined that the maximum overflow from the FCRID to the FCO was 523 cfs.Assuming the 100-year capacity of the channel is 860 cfs, per the 1988 report,the maximum release rate from the Site is 337 cfs. For the purpose of this overall report,a reduction factor of 25%was applied to this capacity,resulting in an allowable release rate of 252.75 cfs. The 100-year capacity will need to be verified through hydraulic modeling of the FCO, and final design of the project may utilize the modeled excess capacity of the FCO. Undetained 100-year runoff from the West Site will be discharged to the FCRID at a rate of 118.88 cfs. During the 100-year event, the FCRID overflows to the FCO. The constructed wetland pond outlet structure will be designed to release the 100-year runoff from the East Site at a rate of approximately 132.87 cfs. The detention pond outlet structure will be designed to release the 100-year runoff from East Horsetooth Road at a rate of approximately 1 cfs. This results in a total 100-year discharge from the West and East Sites of 252.75 cfs, the maximum allowable. All runoff discharged to the FCO will flow east along the north side of East Horsetooth Road, eventually discharging to the Cache la Poudre River just east of Strauss Cabin Road. Developed runoff from the North Site will discharge to the RFOC along the northeast property line. The RFOC receives 134 cfs of runoff from Rigden Farm Pond 216 during the 100-year storm event.The capacity of the RFOC is 178 cfs,which means there is 44 cfs of remaining capacity in the channel.At the time of this report,the RFOC has not been hydraulically modeled to verify the capacity of the channel; therefore, for the purpose of this overall report, a reduction factor of 25% was applied to the original design capacity, resulting in an allowable capacity of 33 cfs. This reduction factor is a conservative assumption, and the actual capacity of the RFOC will be verified through hydraulic modeling and discussed in future drainage reports. The North Site and the future East Community Park (planned for the lot located east of the North Site)will discharge developed flow to the RFOC. The allowable capacity of the channel was apportioned based on the acreage of the North Site and the future park, 20.29 and 57.97 acres, respectively, resulting in an allowable 100-year discharge of 9 cfs, for the North Site, and 24 cfs for the future park. See Appendix C for SWMM summary tables. The outlet structure for the North Site detention pond will be designed to release the 100-year storage volume at or below 9 cfs. Runoff discharged to the RFOC will flow southeast and discharge to the Cache la Poudre River, east of Rigden Reservoir. 3.3 Low Impact Development(LID) The City of Fort Collins requires the implementation of Low Impact Development (LID) systems to treat 75% of newly added or modified impervious areas. Several LID systems were evaluated for the East Site, including bioretention, infiltration trenches, and constructed wetlands. Bioretention rain gardens were preliminarily sized to treat the WQCV of the East Site. Per Mile High Flood District(MHFD) design guidelines for Bioretention Systems (Fact Sheet T-3), the maximum WQCV depth is 1-foot, which results in a required rain garden treatment area of approximately 3.6 acres. Fort Collins requires a minimum of 30 inches of filter media and bedding material, which would total approximately 14,500 cubic yards of material for the treatment area. Because of the size requirements and volume of bedding material required,rain gardens were determined to be impractical for the East Site. Infiltration trenches cannot be implemented because of the high groundwater levels on the Site.Therefore, a constructed wetland pond (CWP) is proposed to treat the WQCV of the East Site. The permanent pool volume was calculated per equation RP/CWP-1 of the MHFD Fact Sheet T-7, and was determined to be 2.69 acre-feet. See Appendix C for preliminary sizing calculations of the CWP. The permanent pool of the CWP will be maintained through exposed ground water, which will require a pond well permit, as well as water rights. The estimated area of exposed groundwater is approximately 3.78 acres, which includes the constructed wetland pond (2.91 acres) and the conveyance swale (0.87 acres). The 2.91 acres of permanent wetland will mitigate the effects of removing 0.14 acres of existing wetland on the West Site. Prepared:November 2024 Page 10 of 13 Overall Drainage Report Strauss Lakes LID will not be implemented for the East Horsetooth Road widening. The impervious area of East Horsetooth Road will account for less than 25% of the entire Site, and therefore can be excluded. LID for the North and West Sites will be implemented locally through the use of grass buffers, grass swales, rain gardens, permeable pavers, and other LID features,as needed to meet the 75%requirement of the City. LID features will not be provided within right-of-way,or within single-family private lots, per section 6.1 of the FCSCM. 3.4 Municipal Separate Storm Sewer System(MS4)Permit Per the Colorado Department of Public Health and Environment's (CDPHE) COR090000 Municipal Separate Storm Sewer Systems(MS4) Permit,the Site must meet one of the post-construction base design standards. This Site will be designed to meet the WQCV standard, by capturing and treating 100%of the WQCV for the applicable development site (excluding up to 1 acre).This standard will be met through the use of a water quality pond, as described in section 3.1.1, a constructed wetland pond, as described in section 3.1.2, and an extended detention basin, as described in section 3.1.3. 3.5 Detention&Flood Control The West Site will not have flood control, and will release the undetained 100-year runoff directly to the FCRID. During the a 100-year event,the FCRID overflows to the FCO. Per SWMM,the preliminary 100-year runoff from the West Site is 118.88 cfs. This will be reduced to some degree with the runoff is routed through the water quality facilities, which will provide some detention capacity.A detailed analysis of this will be included in future drainage reports. The 100-year runoff of the East Site will be detained in the constructed wetland pond,and will be released to the receiving body(FCO)at a controlled rate,via an outlet structure. Preliminary sizing of the constructed wetland pond was performed using SWMM, and the maximum storage volume was determined to be 455,107 cubic feet, or 10.45 acre-feet. For a preliminary WQCV of 3.58 acre-feet, this results in a required 100-year storage volume of 6.87 acre-feet. A preliminary pond with a footprint of approximately 5 acres was evaluated in SWMM. See Appendix C for SWMM summary tables. To account for the undetained discharge from the West Site, the CWP outlet structure will be designed to release the 100- year volume at a rate of approximately 132.87 cfs,which is equal to the capacity of the FCO(252.75 cfs), minus the direct discharge from the West Site (118.88 cfs). The 100-year runoff of the North Site will be detained in the extended detention basin, and released to the RFOC. The detention pond was preliminarily sized using the Modified FAA Procedure,and the 100-year storage volume was estimated to be 3.68 acre-feet. The WQCV of the North Site was calculated to be 0.80 acre-feet, resulting in a total storage volume of 4.48 acre-feet. The pond outfall to the RFOC and the 1-foot freeboard requirement limits the storage depth of the pond to approximately 1-foot,which will require fill of the Site. This results in an approximate pond footprint of 4.87 acres. This footprint could be reduced by importing additional material to the Site. See Appendix C for preliminary Modified FAA calculations.The detention pond outlet structure will be designed to release the 100-year volume at a rate of 9 cfs, based on the allowable capacity in the channel, refer to section 3.2. The developed 100-year runoff from East Horsetooth Road will be detained in an extended detention basin, located south of the road, on City property. The pond was preliminarily sized using the Modified FAA Method, and the 100-year storage volume was estimated to be 1.46 acre-feet. The WQCV was estimated to be 0.25 acre-feet, resulting in a total required storage volume of 1.71 acre-feet.The available pond working depth south of East Horsetooth Road is estimated to be 4.5- feet, based on preliminary survey. With a one-foot of freeboard requirement, this results in a pond storage depth of 3.5 feet, and an approximate pond area of 0.75 acres. Prepared:November 2024 Page 11 of 13 Overall Drainage Report Strauss Lakes 4.0 CONCLUSIONS 4.1 Compliance with Criteria This overall drainage report is in compliance with the provisions outlined in the Fort Collins Stormwater Criteria Manual. 4.2 Draina_pe Concept The proposed drainage system will improve Site drainage through the following methods: • The 100-year developed runoff of the North Site will be detained and released to the RFOC at a rate proportional to the remaining capacity in the channel. This will reduce the amount runoff discharging to the adjacent property to the east. • The 100-year developed runoff from the East and West Sites will be released to the Foothills Channel Outfall at a rate equal to the remaining capacity of the channel. • Low Impact Development systems will be implemented to treat a minimum of 75% of the new or modified impervious area. • 100%of the water quality capture volume of the applicable development site(excluding up to 1 acre)will be treated, per CDPHE MS4 requirements. The preliminary design of the drainage system is in accordance with applicable design standards and criteria, and is therefore not anticipates to have an adverse impact on the existing drainage conditions of the Site nor its immediate vicinity. 5.0 REFERENCES • Cache la Poudre River Master Drainageway Plan. Ayres Associates, EDAW.August 2001. • Final Design Report for the Fossil Creet Reservoir Inlet Ditch Storm Water Overflow. Donohue&Associates, Inc. March 1988. o Addendum to the Final Design Report for the Fossil Creet Reservoir Inlet Ditch Storm Water Overflow. Donohue&Associates, Inc. September 1988. • Final Drainage and Erosion Control Report Rigden Farm—Filing Six. JR Engineering. Revised February 8, 2002. • Fort Collins Stormwater Criteria Manual. City of Fort Collins. December 2018. • Fox Meadows Basin Drainage Master Plan Update—50-Year Alt. Plan. ICON Engineering, Inc. December 6, 2002. • Fox Meadows Basin Drainage Master Plan Update Phase A—Baseline Hydraulics and Problem Identification Report. ICON Engineering, Inc. Revised February 2003. • Fox Meadows Basin Drainage Master Plan Update Selected Plan Report. ICON Engineering, Inc. Revised February 2003. • Hydraulic Analysis of Fossil Creek Reservoir Inlet Ditch Between Cache la Poudre River and Harmony Road Prepared:November 2024 Page 12 of 13 Overall Drainage Report Strauss Lakes for Future Strauss Lake Development. Anderson Consulting Engineers, Inc.April 30, 2020. • Hydraulic Analysis of the Fossil Creek Reservoir Inlet Ditch Controlled Spill System. Anderson Consulting Engineers, Inc. December 2,2002. • Urban Storm Drainage Criteria Manual. Mile High Flood District. Partially updated March 2024. Prepared:November 2024 Page 13 of 13 APPENDIX A Figures & Tables r LL NIA go .k Strauss Lakes Vicinity Map F -t Collins, CO or k... t SUNLQWI=R' _ 'J LO r EIhZbet H;S=� RI �R CG LIi�lS IGH SCE UC} � -. . • - _ � r 1 _ ( a t r 1 r s ect,i~2 eE.i?rosPe } F _ t '�frt.mat �' • .2 ;,., � h+ A. 1 k HQRS�E m S.4ldTFi:,CQLLECE HEIQ11 v � SC.rJ CH ,PINE Tory I p '�, A� E, .0 F1mQQR t ILLAG R if PIRA lorsetootra Rd-° ar- � �-r-- - - E Horsetodth-01 k �O"- w j1 JTMP II I FAIN 4 ' ,'t "'^ Ex { N�21 RP NCI -,I HE LANDINGS �... 1 1 ��tm �� m • ARI't1QNY P/�RI�e " � nY . Y t . `Ile .Earthy �, `` Hydrologic Soil Group—Larimer County Area,Colorado R: (Strauss Lakes) 0 o qqq 498100 498300 498500 498700 498900 499100 499300 40°33'13"N — 40°33'13"N S. I � d. ei ffi .. -. ML Soil Map may not be valid at this scal=. 40°32'11"N 40°32'11"N 498100 498300 498500 498700 498900 499100 499300 3 3 Map Scale:1:9,330 fi printed on A portrait(8.5"x 11")sheet. b Meber N s ° 0 100 200 400 600 Feet 0 450 900 1800 2700 Map projection:Web Mercator Comer coordinates:WGS84 Edge tics:11TM Zone 13N WGS84 USDA Natural Resources Web Soil Survey 7/12/2024 i Conservation Service National Cooperative Soil Survey Page 1 of 4 Hydrologic Soil Group—Larimer County Area,Colorado (Strauss Lakes) MAP LEGEND MAP INFORMATION Area of Interest(AOI) 0 C The soil surveys that comprise your AOI were mapped at Area of Interest(AOI) CID 1:24,000. 0 Soils ® D Warning:Soil Map may not be valid at this scale. Soil Rating Polygons A Not rated or not available Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil F—] AID Water Features line placement.The maps do not show the small areas of Streams and Canals contrasting soils that could have been shown at a more detailed 0 B scale. Transportation B/D . Rails Please rely on the bar scale on each map sheet for map 0 C measurements. � Interstate Highways 0 C/D US Routes Source of Map: Natural Resources Conservation Service Web Soil Survey LIRL: 0 D Major Roads Coordinate System: Web Mercator(EPSG:3857) 0 Not rated or not available Local Roads Maps from the Web Soil Survey are based on the Web Mercator Soil Rating Lines Background projection,which preserves direction and shape but distorts q distance and area.A projection that preserves area,such as the Aerial Photography Albers equal-area conic projection,should be used if more .-.. AID accurate calculations of distance or area are required. ++� B This product is generated from the USDA-NRCS certified data as ti B/D of the version date(s)listed below. C Soil Survey Area: Larimer County Area,Colorado Survey Area Data: Version 18,Aug 24,2023 r.i CID Soil map units are labeled(as space allows)for map scales ... D 1:50,000 or larger. Not rated or not available Date(s)aerial images were photographed: Jul 2,2021—Aug 25, Soil Rating Points 2021 p A The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background E3 AID imagery displayed on these maps.As a result,some minor B shifting of map unit boundaries may be evident. B/D USDA Natural Resources Web Soil Survey 7/12/2024 Conservation Service National Cooperative Soil Survey Page 2 of 4 Hydrologic Soil Group—Larimer County Area,Colorado Strauss Lakes Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 22 Caruso clay loam,0 to 1 D 79.3 43.7% percent slope 35 Fort Collins loam,0 to 3 C 22.1 12.2% percent slopes 53 Kim loam, 1 to 3 percent B 16.5 9.1% slopes 62 Larimer-Stoneham B 14.1 7.8% complex,3 to 10 percent slopes 64 Loveland clay loam,0 to C 0.0 0.0% 1 percent slopes 73 Nunn clay loam,0 to 1 C 11.1 6.1% percent slopes 74 Nunn clay loam, 1 to 3 C 0.31 0.1% percent slopes 101 Stoneham loam, 1 to 3 B 10.8 6.0% percent slopes 102 Stoneham loam,3 to 5 C 3.5 1.9% percent slopes 105 Table Mountain loam,0 B 15.1 8.3% to 1 percent slopes 136 Water 8.6 4.7% Totals for Area of Interest 1+81.3 100.0% USDA Natural Resources Web Soil Survey 7/12/2024 Conservation Service National Cooperative Soil Survey Page 3 of 4 Hydrologic Soil Group—Larimer County Area,Colorado Strauss Lakes Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D)and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential)when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential)when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher USDA Natural Resources Web Soil Survey 7/12/2024 Conservation Service National Cooperative Soil Survey Page 4 of 4 NOTES TO USERS Cache La LEGEND This map is for use in administering the National Flood Insurance Program. It Poudre River SPECIAL FLOOD HAZARD AREAS (SFHAs) SUBJECT TO does not necessarily identify all areas subject to flooding, particularly from local Split R Path INUNDATION BY THE 1% ANNUAL CHANCE FLOOD drainage sources of small size. The community map repository should be 3135000 FT 1��4894 105,00,00.01, The 1% annual chance flood (100-year flood), also known as the base flood, is the flood consulted for possible updated or additional flood hazard information. 105101'52�5" JOINS PANEL 0984 4013345.0" that has a 1% chance of being equaled or exceeded in any given year. The Special 40133'45.0" ..... . .... ........ . .......... ...................... Flood Hazard Area is the area subject to flooding by the 1% annual chance flood. Areas To obtain more detailed information in areas where Base Flood Elevations RIVERBEND COURT-/ of Special Flood Hazard include Zones A, AE, AH, AO, AR, A99, V and VE. The Base ............. LUN E:A:E "'ISIS ......... .. .................................... .. .1-1:­11111":....:,-.. - Flood Elevation is the water-surface elevation of the 1%annual chance flood. (BFEs) and/or floodways have been determined, users are encouraged to consult ........ ...........: : ::: ii LARIMER COUNTY I........................ :SISSISIS ....................................... X-N.I.-N., the Flood Profiles and Floodway Data and/or Summary of Stillwater Elevations UNINCORPORATED AREAS ZONE A No Base Flood Elevations determined. ............. .. ............ tables contained within the Flood Insurance Study (FIS) report that accompanies Z .................................... .. . . ............ OLLINS 080101 CITY OF FORT C ZONEAE Base Flood Elevations determined. ................................... this FIRM. Users should be aware that BFEs shown on the FIRM represent ".. .......I.".,.,.,.,.,."..'�..'-.,.,.,.,.:.."."..,::..".,.,.,.,..".,,.:.."..,.,..',..'-..'.- 080102 ZONEAH Flood depths of I to 3 feet (usually areas of ponding)- Base Flood rounded whole-foot elevations. These BFEs are intended for flood insurance .................. rating purposes only and should not be used as the sole source of flood Elevations determined. P.RbFILE �.�: FLOODING EFFECTS:FROM 9 44 000M elevation information. Accordingly, flood elevation data presented in the FIS 48 Boxelder Creek 1-25 Split 90 IN ZONEAO Flood depths of I to 3 feet (usually sheet flow on sloping terrain); ....... ....................... BASELINE RIVER. .. .... ............ .21 Sx, report should be utilized in conjunction with the FIRM for purposes of AE PROFILE BASE LINE average depths determined. For areas of alluvial fan flooding, velocities iij�iiijil Pitch�Diversio SPLITL�PATR also determined. construction and/or floodplain management. ZONE AE '/VP D ........ ... ZONE AR Special Flood Hazard Area formerly protected from the 1% annual .. . ... .... ... .. ....... Coastal Base Flood Elevations shown onthis map apply only landward ... . ... ... . ... ... .. . ....... .. chance flood by a flood control system that was subsequently 4D of 0.0' North American Vertical Datum of 1988 (NAVD 88). Users of this ... decertified. Zone AR indicates that the former flood control system is 4905 S being restored to provide protection from the 1% annual chance or FIRM should be aware that coastal flood elevations are also provided in the 41893 greater flood. Summary of Stillwater Elevations table in the Flood Insurance Study report "'S for this jurisdiction. Elevations shown in the Summary of Stillwater Elevations ZONE A99 Area to be protected from 1% annual chance flood by a Federal C, MCLAUGHLIN LANE table should be used for construction and/or floodplain management purposes to flood protection system under construction; no Base Flood Elevations when they are higher than the elevations shown on this FIRM. --Boxelder Creek 1-25 determined. NX ZONE V ..... ... Coastal flood zone with velocity hazard (wave action); no Base Flood Boundaries of the floodways were computed at cross sections and interpolated Split Overflow Elevations determined. Boxelder Creek 4899 between cross sections. The floodways were based on hydraulic considerations ZONE VE r-xx Coastal flood zone with velocity hazard (wave action); Base Flood -T1 with regard to requirements of the National Flood Insurance Program. Floodway LL0488 A''t ....... Elevations determined. X vea widths and other pertinent floodway data are provided in the Flood Insurance . .. . ... ... . .... ... 21 4885 Study report for this jurisdiction. FLOODWAY AREAS IN ZONE AE ............. .. ... . ... .... ....... 18 ...... 48821 6, Certain areas not in Special Flood Hazard Areas may be protected by flood 11 1 5SS: �:�NOTE;THIS AREA IS SHOWNA&BEING PPIOTECTED:� The floodway is the channel of a stream plus any adjacent floodplain areas that must be control structures. Refer to Section 2.4 "Flood Protection Measures" of :FROM THE1-PEPICENT-ANNUAL-CHANCE�OPI�GREATER kept free of encroachment so that the 1% annual chance flood can be carried without the Flood Insurance Study report for information on flood control structures FLOOD HAZARD BYW LEVEE:SYSTEM OVERTOPPING:::, substantial increases in flood heights. ......... ................... ... ...... for this jurisdiction. ::OR FAILURE OF�ANY.LEVEE SYSTEKIS�POSSIBLE. FOR 79 ADDITIONAL INFORMATION,:SEETHE"ACCREDITED X­N.N. N OTHER FLOOD AREAS K NOTES TO:USERS. .............. The projection used in the preparation of this map was Colorado State Plane north zone (FIPSZONE 0501).The horizontal datum was NAD83, ZONE X Areas of 0.2% annual chance flood; areas of 1% annual chance flood .............. ........ ... ........... ........ with average depths of less than I foot or with drainage areas less than GRS1980 spheroid. Differences in datum, spheroid, projection or State Plane .............. LARIMER:COUNTY:.::: ...... 0 1 square mile; and areas protected by levees from 1% annual chance .......... . ......... ... ... zones used in the production of FIRMs for adjacent jurisdictions may result in Cach flood. .......... ....UNINCORPORAT D AREAS-, .. 41 slight positional differences in map features across jurisdiction boundaries. ......... .... ......... ...... . .......... ....... .... These differences do not affect the accuracy of the FIRM. :::�:080101:�� Lowflow.... Channel ZONE All= OTHER AREAS .......... ................ .......... .... .. IF Flood elevations on this map are referenced to the North American Vertical ......... ...... ..... ....... ZONE X Areas determined to be outside the 0.2% annual chance floodplain. ............ .......... ...........Datum of 1988. These flood elevations must be compared to structure and .................. ------ .... ZONE D Areas in which flood hazards are undetermined but possible. ground elevations referenced to the same vertical datum. For information ......... ................ ........... ............. .......regarding conversion between the National Geodetic Vertical Datum of 1929 1445000 FT COASTAL BARRIER RESOURCES SYSTEM (CBRS) AREAS and the North American Vertical Datum of 1988, visit the National Geodetic ....... ............. CITY OFFORT COLLIINS:: ......... Survey website at http://www.ngs.noaa.gov/ or contact the National Geodetic ....... ........... ................................. ............... ..................... Survey at the following address: ............................. ........ ............... .......... ................. ............... ....... ........ OTHERWISE PROTECTED AREAS (OPAs) .......... NGS Information Services ................ .................. ........ .............. .... ............. ............ ......................... CBRS areas and OPAs are normally located within or adjacent to Special Flood Hazard Areas. .......... ....NOAA, N/NGS12 .................... ID .................................... ................................... National Geodetic Survey DRAKE ROA ..... ....... .. D ....... ...... Floodplain boundary . ........................... LU .............. ........................ ................. ...... ............. SSMC-3, #9202 > ....... ...... DRIVE:�... ..... .... .. .............. ............................. Floodway boundary ............................................................. 1315 East-West Highway .............. ------------------------------ ...................... .. .... ... .......;................ .. ... Zone D boundary DRIVE ............... Silver Spring, MD 20910-3282 ....... .. .... 44 000M ...... . .... 89 IN CBRS and OPA boundary .................. ............ ..................... ............................. .................................. .......... ..................... . .... . . .. .............. ................... ........................................... To obtain current elevation, description, and/or location information for bench marks 0 ........... ............ LL ......... 7.... ................. .......... shown on this map, please contact the Information Services Branch of the Boundary dividing Special Flood Hazard Areas of different ... . ........ . ............................. ............... National Geodetic Survey at (301) 713-3242, or visit its website at 0 LIMON DRIV Base Flood Elevations, flood depths or flood velocities. .... .... ...... ...................... .................. ............ . . . ........ http://www.ngs.noaa.gov/. 513 Base Flood Elevation line and value; elevation in feet* ............... ..... .......... Base map information on this FIRM was provided by the Larimer County GIS and .......... ... (EL 987) Base Flood Elevation value where uniform within zone; ......... . ... ............. Mapping Department. Additional input was provided by the City of Fort Collins levation in feet* e LL0490 .............. ................................. ........... Geographic Information Services Division. These data are current as of 2010. . .... Referenced to the North American Vertical Datum of 1988 (NAVD 88) ............ ........... .................................. Cross section line This map reflects more detailed and up-to-date stream channel configurations .................. -------- Transect line than those shown on the previous FIRM for this jurisdiction. The floodplains 0 .............. ........................... and floodways that were transferred from the previous FIRM may have been ..... ..... Geographic coordinates referenced to the North American 7-07'30",32-22'301, adjusted to conform to these new stream channel configurations. As a 9 --------- --- --- Datum of 1983 (NAD 83) result, the Flood Profiles and Floodway Data tables in the Flood Insurance ........... 1000-meter Universal Transverse Mercator grid ticks,zone 13 42 Study report (which contains authoritative hydraulic data) may reflect stream 75000mN channel distances that differ from what is shown on this map. .................................. 5000-foot grid ticks: Colorado State Plane coordinate 6000000 FT system, north zone(FIPSZONE 0501),Lambert Conformal Conic .............................. ... Corporate limits shown on this map are based on the best data available 0 JOSEPH DR. 0 0 at the time of publication. Because changes due to annexations or de-annexations 0 A may have occurred after this map was published, map users should contact ... ... Bench mark (see explanation in Notes to Users section of ......... ............... ..... ......... . . ...... ......... DX551 0 ...... LLI appropriate community officials to verify current corporate limit locations. X this FIRM panel) Lu AN .......... ........ ....... Z ......... /S Z < ... ............. M1.5 W.4,, .............................. U) .................. ......... Please refer to the separately printed Map Index for an overview map of the River Mile county showing the layout of map panels;community map repository addresses; 0 M �,FLINGER DRIVE C) 0 Z Z MAP REPOSITORIES and a Listing of Communities table containing National Flood Insurance Program 0 .11. .........s 0 Refer to Map Repositories list on Map Index dates for each community as well as a listing of the panels on which each ...... .... community is located. ................ ......... EFFECTIVE DATE OF COUNTYWIDE ....... ...... CO, < PARKWAY FLOOD INSURANCE RATE MAP For information and questions about this map, available products associated with this December 19,2006 FIRM including historic versions of this FIRM, how to order products or the National EFFECTIVE DATE(S)OF REVISION(S)TO THIS PANEL Flood Insurance Program in general, please call the FEMA Map Information eXchange 29 . ...... ... 0) May 2,2012-to change Special Flood Hazard Areas, to change floodway, to reflect updated at l-,877-FEMA-MAP (1--877-336-2627) or visit the FEMA Map Service Center website topographic information, to change Base Flood Elevations,and to incorporate previously issued BANK DRIVE Letters of Map Revision. at http://msc.fema.gov.Available products may include previously issued Letters of Map SLADE STREET M < Change, a Flood Insurance Study Report, and/or digital versions of this map. Many of 0 ...... ........... .............. these products can be ordered or obtained directly from the website. Usersmay ... . ...... determine the current map date for each FIRM panel by visiting the FEMA Map . . ... .......... RED CLOUD COURT Service Center website or by calling the FEMA Map Information eXchange. For community map revision history prior to countywide mapping,refer to the Community 0 GO- Map History table located in the Flood Insurance Study report for this jurisdiction. .......... To determine if flood insurance is available in this community, contact your insurance 00 RED MOO Accredited Levee Notes to Users: Check with your local communi ty to obtain MAROON C01jr, agent or call the National Flood Insurance Program at 1-800-638-6620. 44 000M more information, such as the estimated level of protection provided (which may exc ... . ...... 88 IN COURT rn eed the I-percent-annual-chance level) and Emergency Action Plan, on the Fossil Creek Reservoir Inlet Canal G levee system(s) shown as providing protection for areas on this panel. To mitigate flood risk in residual risk areas, property owners and residents are DRIVF MAP SCALE 1 500' encouraged to consider flood insurance and floodprocifing or other protective < 250 0 500 4863 0 1 measures. For more information on flood insurance, interested parties should METERS 150 0 150 300 visit the FEMA Website at http://www.fema.gov/business/nfip/index.shtm. 3e\PJELSTONE COURT .. ......11.:....:�.* M LU ........ ..... UJ N PANEL 0992G 01 .................................... . ........... 1440000 FT us 0 C1. DRIVE FIRM FLOOD INSURANCE RATE MAP > ................ C11 UJ DRIVE Z 0 E COURT BLACKSTO LARIMER COUNTY, ............ 0 < SETOO HOR TH '4858 AND INCORPORATED AREAS LU ...... > ANTELOPE ROAD . ......... .......... ............ ........... cc ........ PANEL 992 OF 1420 U col/%, OtA ... ............ .... . . .... . ..... . .. .. (SEE MAP INDEX FOR FIRM PANEL LAYOUT) 0 CONTAINS ........... COURT 44/ Q - 34 COMMUNITY NUMBER PANEL SUFFIX \Nr NOTE: MAP AREA SHOWN ON THIS PANEL IS LOCATED ............. ....... 0 MICHELLE LANE LARIMER COUNTY 080101 0992 G WITHIN TOWNSHIP 7 NORTH, RANGE 68 WEST. .. ... . ... .. ... .. . FORT COLLINS,CITY OF 080102 0992 G 0 0 > .......... ...... ........... . ....... ..... 0 ...... 0 ...... ........ ........ BISON rZ cr rn 32 < Y DRIVE 33 CHARLIE cc LARIMER COUNTY .. 44 000M 0 87 IN WHITWORTH DRIVE DRIVE ........ Z UNINCORPORATED AREAS . . ... ... W CITY OF FORT COLLINS CITY OF FORT COLLINS 080101 080102 LJ 4 080102 "F-SA VERDE Notice to User: The Map Number shown below should be DRIV used when placing map orders; the Community Number shown < above should be used on insurance applications for the subject > .... . 0 community. Z ...... Z LU 11IVE 0 Z :D CANYON S 08069CO992G ....... MAPNUMBER sTRES1 .... . ... ... pp,DDINGTON ROAD 40131'52.5" T 77 40131'52.5,, r JOINS PANEL 0994 105'00'00.0" MAP REVISED 105101'52.5" 498000m E 4 99000m E ND 5 MAY 2, 2012 Federal Emergency Management Agency �city. CoTns Fort Collins Risk Map cis Legend •� �. a g ! "aEl Growth Management Area a.� a4, •1 M+ �.. City Limits Percent Annual Chance Grids C >0.2%-1% ' 5 ~" >1%-2% >2%-4% � 'C ■ >4%-10% Citations kW y w � - S Efa O�+ Ct1 Ir'e rr.he Ir,o n r , t �• ,gona Ridge r........... �.:4 1: 18,056 oprionnow �. Notes 0.6 0 0.28 0.6 Miles This map is a user generated static output from the City of Fort Collins FCMaps WGS_1984_Web_Mercator_Auxiliary_Sphere Internet mapping site and is for reference only.Data layers that appear on this City of Fort Collins-GIS map may or may not be accurate,current,or otherwise reliable. FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards(Ch. 5) 4.0 SWMM 4.0 SWMM This section is for project sites that require the use of the Stormwater Management Model (SWMM) to determine storm hydrograph routing and is the only method that is able to assess the overall performance of multiple detention basins in parallel or in series in a particular project site or watershed. Reference: The theory and methodology for reservoir routing is not covered in this Manual as this subject is well described in many hydrology reference books. The EPA SWMM Reference Manuals, dated January 2016, have been utilized in preparing the information in this section of the Manual. 4.1 Input Parameters Table 4.1-1 provides required input values to be used for SWMM modeling. Basin and conveyance element parameters must be computed based on the physical characteristics of the site. Table 4.1-1. SWMM Input Parameters Depth of Storage Impervious Areas 0.1 inches Pervious Areas 0.3 inches Infiltration Parameters Maximum 0.51 in/hr Minimum 0.50 in/hr 0.0018 in/sec or Decay Rate 6.48 in/hr Zero Detention Depth 1% Manning's"n" Pervious Surfaces 0.250 Impervious Surfaces 0.016 For Overall Drainage Plan (ODP) and Project Development Plan (PDP) submittals, when surface types may not yet be known, land uses may be used to estimate impervious percentages. Table 4.1-2 lists the percent imperviousness for common types of land uses in the City. City of 4.1 Input Parameters i'^Fort Collins Page 10 FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards(Ch. 5) 4.0 SWMM Table 4.1-2. Land Use-Percent Impervious Percent Impervious Land Use N Residential Urban Estate 30 Low Density 50 Medium Density 70 High Density 90 Commercial Commercial 80 Industrial 90 Undeveloped Open Lands,Transition 20 Greenbelts,Agriculture 2 Offsite Flow Analysis(when Land Use not defined) 45 Reference: For further guidance regarding zoning classifications, refer to the Land Use Code, Article 4. For Final Plan (FP) submittals, impervious values must be based on the proposed land surface types. Refer to Table 4.1-3 for recommended percent impervious values. Table 4.1-3.Surface Type—Percent Impervious Percent Impervious Surface Type N Hardscape or Hard Surface Asphalt, Concrete 100 Rooftop 90 Recycled Asphalt 80 Gravel 40 Pavers 40 Landscape or Pervious Surface Playgrounds 25 Lawns, Sandy soil 2 Lawns, Clayey soil 2 City of 4.1 Input Parameters '^Fort Collins Page 11 FORT COLLINS STORMWATER CRITERIA MANUAL Hydrology Standards(Ch. 5) 4.0 SWMM The composite imperviousness is obtained using the following formula: n I(I;xAj I= `-1 A Equation 5-6 Where: I = Composite Imperviousness, I; = Imperviousness for Specific Area (A), A; =Area of Surface with Imperviousness of I;, acres or square feet n = Number of different surfaces to be considered At=Total Area over which I is applicable, acres or square feet 4.1.1 Intensity-Duration-Frequency Curves for SWMM The hyetograph input option must be selected when creating SWMM input files. Hyetographs for the 2- year, 5-year, 10-year, 25-year, 50-year, and 100-year Fort Collins rainfall events are provided in Table 4.1-4. Table 4.1-4. IDF Table for SWMM Intensity Intensity Intensity Intensity Intensity Intensity Duration 2-year 5-year 10-year 25-year 50-year 100-year min in/hr in/hr in/hr in/hr in/hr in/hr 5 0.29 0.40 0.49 0.63 0.79 1.00 10 0.33 0.45 0.56 0.72 0.90 1.14 15 0.38 0.53 0.65 0.84 1.05 1.33 20 0.64 0.89 1.09 1.41 1.77 2.23 25 0.81 1.13 1.39 1.80 2.25 2.84 30 1.57 2.19 2.69 3.48 4.36 5.49 35 2.85 3.97 4.87 6.30 7.90 9.95 40 1.18 1.64 2.02 2.61 3.27 4.12 45 0.71 0.99 1.21 1.57 1.97 2.48 50 0.42 0.58 0.71 0.92 1.16 1.46 55 0.35 0.49 0.60 0.77 0.97 1.22 60 0.30 0.42 0.52 0.67 0.84 1.06 65 0.20 0.28 0.39 0.62 0.79 1.00 70 0.19 0.27 0.37 0.59 0.75 0.95 75 0.18 0.25 0.35 0.56 0.72 0.91 80 0.17 0.24 0.34 0.54 0.69 0.87 85 0.17 0.23 0.32 0.52 0.66 0.84 90 0.16 0.22 0.31 0.50 0.64 0.81 95 0.15 0.21 0.30 0.48 0.62 0.78 100 0.15 0.20 0.29 0.47 0.60 0.75 105 0.14 0.19 0.28 0.45 0.58 0.73 110 0.14 0.19 0.27 0.44 0.56 0.71 115 0.13 0.18 0.26 0.42 0.54 0.69 120 0.13 0.18 0.25 0.41 0.53 0.67 Cjtyof 4.1 Input Parameters F6rt Collins Page 12 APPENDIX B Reference Reports ,. w' 4 L ''� ` - I - — _ Wr I. � '�► fit' 5 r � , ,� � , _ � � _� � •�` `�,'� _ . Fox Meadows Basin -t. t • I : r 9 , ° � .. ! .y �` L. ' - _ a_y � n• . 1. ': - ', ';� iN. ' � ry$ t. Proposed BMP Basin Type r - . a :. . .: ,: a• A Y• . _�--- FloodControl n , I' "" r Pik L r y i Water QualityOnly _ ` T o + _ Flood Control and Water Quality - Y � • `I. _ A' I ' ..• - - -• ,� ' a..� _ �, ems..�.. _ _ * �k}€� ! __ • , : i Yl _ I _ ` d,, t� ��.,,y'�•� - y' - y r �R , 1�a :.a' '�k!"R,,+ Ma= . . - $!WARProposed Improvements - •' Stone Ridge Pond p -^+i (, �! yqE+. o ,� ` ', tY� �' •'"f '� - .may.. ra, , pB 5 �e a' F RID Pond b � w C , �• - , _ • ,,' - ., ���;, Fox Meadows Pond _ erna ►ve o ID locat►o ( DB N Pond taccommodate A t t t FCR • � A ' , .... '�' � New on o 4 Retrofit Existing Pond to accommodate rl = Proposed Selected Plan n f _ Water Quality Volume p Lab -� Water Quality Volume !. z s, �L: � Proposed I i I' I, + - — , I i : ; : Z* 1- ` . Water QualityAlternatives -f - Ilk" 5 `i �. 1 .C. ed .P i y sE t � • ' I Sunstone Village Regional Pond ' �zw ► "{ • Retrofit ExistingPond to accommodate �.. ' r Collindale Golf Course _, s,f } - + t`,. : _ : � " ' s Water Quality Volume - ,: F • Source Control BMP's L - :r .,-: .,7!" - � +� .. u. f r e j'a y� .�.•. _.2 + ,- .p� •, . � - I , W . �§.f . _ _� - _ � � �- err see report text - E HORSETOOTH RDCO RD 40 - -- — r • - - . . - s • -v O r it � - `SDI' i� � � s• i' I .ems- w ?. � � •� �� _ _ _y I 3 - ri - ! - �I 4.-1 � , : -• - ' _':.'�',g'[i - •~ ., _ _ - - i� '. gip... ,. l •. � E d _ � ■ - - - ' B -J--i I - - i!i� 'M .,fir_ •I r _ � — - .C . - � , �� '!Sol I a - r , •' - i ! " q co 1 5- It s - •` ' W '� s _ 0 'Z Y and to accommodate Woodland Park Pond } • - .�, - .'� I ,r , _, ,��= ,��:," � Retrofit Existing P e - 9 Water Quality Volume Q II _ a. r j �_ 1 +� _ # ' — d 4 '�l °f- � ,^ � • .tea r'-•,b `,- ,. gl'y�la- l�. �J��1lj -. s r✓• I«it • ` i -� �• ,r5 i �. & ice. Y e 1171 ri E HARMONY RD 40 Golden Meadow Pond I — -- rl, �t ,- Hewlitt-Packard Ponds Retrofit Existing Pond to accommodate ' � . ,-� IC • Retrofit Existing Pond to accommodate �. Water Quality Volume Water Quality Volume ._�•, - ., ei.' V _ M ` r -9 .al r. a. .r �' '4� •i .,.�3.Wx ;i7 -- - ._.,..1 •l � . I I�. 7 �i ��,, •.' I , i ,. �, i r t a' _ _- .,t:l.'""f�' 1 �'"FfA+ . i •l i L• '�y i • •Y .. `.ter N 1 fr... . ®' r •, � � I r..' � .I n _;,,. _ — Wig,_.- l:r T 9 - �' , �.. u �Ity of N Fox Meadows Basin 0 500 1,000 1,500 2,000 W � Feet ",r- artCollinsI r Selected Plan = Water QualityImprovements1 inch = 500feetENGINEERING INC. ihhlfi�: a �Uif. u iF fs Addendum s, to The Final Design Report for = �k The Fossil Creek Reservoir Inlet Ditch ' tiyf Storm Water Overflow ` a September 198 {3. 8 fist.:•4 -- -i }�K a, City of Fort Collins Storm Water Utility f � tt 15y f. I cf gfY t Donohue & Associates, Inc. 7 4 4730 South College Avenue Fort Collins : , Colorado 80525 J: 226-2323 K.`` k' �,i Project No. 272. 000 ,} �! G; •� {(yi{J15 yt `�sf'•13�a`s' w ,etfr r, SUMMARY The review of the "Final Design Report for the Fossil Creek Reservoir Inlet Ditch Storm Water Overflow" by the City of Fort Collins and the other affected property and ditch owners indicated several refinements to the design were desirable. 1 These design refinements include improvements in alignment, hydraulics, operations and maintenance considerations, safety and "- coordination with existing. facilities. �a> r ' The appropriate figures from the Final Design Report have been modified to reflect the revised design concept and are included 4- in this addendum. The design as outlined in this addendum will be used to prepare the construction documents and easement descriptions for this project. DESIGN REVISIONS lti The basic channel design has been modified to occupy the smallest amount of easement space possible while still meeting the City of Fort Collins criteria for major drainage channels. The channel design criteria is as follows: `` . Design flow, 100-year recurrence interval 860 CFS Maximum depth at 100-year flow 4 feet Y; Friction factor (n) 0. 04 Side Slopes 4 : 1 Maximum desirable velocity 5 FPS The channel is routed due east along the north side of County <` Road 40 . The south side of the channel is 34 feet from the south section line of Section 28 which is the centerline of County Road 4 40. The existing right-of-way (ROW) for County Road 40 is 30 feet either side of the section line. The additional four feet .' of setback is for the anticipated ROW required for the City of <<` Fort Collins standard 'collector street which will be constructed , in the future when the area is annexed. The channel parallels County Road 40 to the east side of County Road 7 where it turns south across the County Road 40 ROW making a smooth confluence with the Poudre River. The basic channel ROW requirements are an 80-foot wide ROW west of the Box Elder Ditch and a 100-foot ROW east of the Box Elder Ditch. The channel alignment utilizes a minimum of private property and county road ROW. x A seven percent grade section of channel in the first reach (Sta. 0+00 to Sta. 1+00 will cause a hydraulic um to occur in the ) Y jump channel at approximately Sta. 0+80. The hydraulic jump will be weak and submerged under most conditions. Riprap channel protection will be provided from Sta. 0+00 to Sta. 1+20 to insure ' Y. E s' ,y��.. , . a•. -.-,_. ... .._ ,. :.-,:_. ,, ., r.. �. ♦ .;:-Y � 1 '_I V J'.r 945, � P ',l+,x :-;. >P,xM•pt�y"+•S R+r.a...:it _ ..:. , - > '-. _ , 'SG,.: ...,'.r .:r .' � � 3 :. yy-.,+1 r 1:.• ..rr '� �.`.i +'i 2 - .. m:.. '-, � .. f. dd�.. -.. 1•.�-, TI r. ..: y:."�,.: `. ,;c; 'i�. J a�}?:is �'t�- :�:e-3 rr�„i.•dr !+ .>:� .s — -Mr- �.ZR Y„�4:-.. 4`[ i - -.� � -.-�: ."f.- � .._.ram ., -.• t f '1.s .1 �'/>< _ .-:i.. � _ - - _� r ., � •P... lr ..�a:, ''1Fj-;.•r.,a' _..rye�•s Sy„ x 1 , �..r`fir .:- , .< _ ,::•..: E-.:',: 4_..z_+,:, .,=P. .. :k.r _ '. CA lk Im-ma 'R'i'..+:.,.�at,Yc.s•'�c;reset»`i�M �w`k�...f,4s�',mr.,.,- O - },a ,;y�.� ..::,..Y. .� .:�`'���'�raY,ii,:...^� -+'.:�, s..-. :_.. _ .>a....,i,o ss. .so._ ..n Y...�51�7,.a:.a.•r ��.+.� + - IMIL r_ . `�`.� z • • 1 1 1 zYq • • • �+ 11 5. It •i • ! • • ,u '? OItsm l C WAM . i 1I ■, • 1 S' *. Q Ads / / 1 II / / i / : 11 / II li / 1 / 1 . / / 40 11 it ! / �` '1. !. .h t- 'era' •,St`o�°t- ,-.�.__...,....,!k5ra.ii...1.r..-..-.k...>'.2,d.K.,,..�.:4_u.._.%�,,..r°�E..k.•�€S._a_�.i��:s:.,,._v..:... ��e<v_S:,_�.$:.�"��3_-tru'._�...t'."�_"':�.e....,x:t<;rae.Ey_i<•___,x.....,._...-��.t,. i„_s-,ssx�.e__z,1_.m�s:....•zr< ,+.._,>_._�Sssa,'3:.R-.tx...,_.�,.:¢o,,,.�rt<�>ti+�.?�_., :_vY.xL..r,-._�.rr_.�::�4s'E-...'. -. ,m�'.s3�:: , :-�°+`: { .rr .>_�.. < ,,.'h.,4,,:.,..d_:a.,,,.. �.,^$._L�4 .'_�1� �«_a•.x _ .-.. .__,:-� MEMORANDUM N ANdtit5uN CUNSUIHNy EMIiNWO, 1011- 001 - ff&,P—Resouives • Fnr+i+o n e nlal DATE: April 30, 2020 ACE PROJECT NO.: COCLF11 TO: Bill McDowell, Manger, Cottonwood Land and Farms FROM: Brian Smith, Anderson Consulting Engineers, Inc. Brad Anderson, Anderson Consulting Engineers, Inc. Mike Turner, Anderson Consulting Engineers, Inc. SUBJECT: Hydraulic Analysis of Fossil Creek Reservoir Inlet Ditch (FCRID) Between Cache la Poudre River and Harmony Road for Future Strauss Lake Development BACKGROUND INFORMATION AND PREVIOUS STUDIES: In 2001 and 2002, Anderson Consulting Engineers, Inc. (ACE) completed a hydrologic and hydraulic evaluation of the Fossil Creek Reservoir Inlet Ditch (FCRID) for Cottonwood Land and Farms. The purpose of this study was two-fold: (1) assess flooding potential along the ditch from large magnitude storms that enter the ditch from the Cache la Poudre River (Poudre River), the Foothills Regional Channel, and local runoff from adjacent neighborhoods; and (2) investigate options for controlling the flooding potential as it pertains to Cottonwood Land and Farms' future development site (Strauss Lake Development) east of the ditch. Recommendations from the 2002 study resulted in the sizing and construction of a bridge/culvert over the ditch at William Neal Parkway, which is located directly to the west of the existing concrete batch plant. An orifice plate was installed on the upstream side of the William Neal Parkway crossing to check flows in excess of the maximum irrigation flow to facilitate the diversion of excess stormwater from the ditch. The 2002 study conceptually envisioned that a lateral overtopping spill structure would be created to spill excess stormwater from the ditch that is being checked by the orifice plate. The lateral overtopping spill would be created by the lowering of the eastern bank of the ditch between the William Neal Parkway crossing and the upstream Environmental Drive road crossing. It is noted that the lowering of the eastern bank of the ditch and installation of this overtopping spillway has yet to be constructed. A vicinity map of FCRID, William Neal Parkway, the conceptual lateral overtopping spill location from the 2002 study, and the study reach evaluated for this study is illustrated in Figure 1. In 2017 and 2018,ACE conducted a calibration study of FCRID between Horsetooth Road and the Great Western Railroad (GWR) for the City of Fort Collins Utilities Department. The purpose of this study was to develop a depth/discharge rating curve of the ditch at the upstream side of the Environmental Drive Bridge crossing that would allow the City and the North Poudre Irrigation Company to estimate the discharge in the ditch based on a water depth reading from a staff gage. Results of this study indicated that the development of a rating curve was possible, but that the rating curve could shift dramatically based on downstream tailwater conditions and roughness values of the ditch. This study also concluded that under current ditch conditions,the maximum flow rate that can be conveyed within the ditch prior to flow spilling over the lateral weir structure upstream of Horsetooth Road is approximately 120 cfs. This maximum irrigation flow rate,and the roughness values determined as part of the calibration study, were utilized as part of this study. It was also realized as part of the 2017/2018 study that the eastern bank of the ditch, upstream of the GWR, was lowered in the early 1990s to create an emergency overflow weir as part of the City's flood control project for the adjacent wastewater treatment plant. The location of the existing low bank/overflow weir is also illustrated on Figure 1. It is noted that the presence of this overflow weir was not incorporated into ACE's 2002 hydraulic evaluation of FCRID. FCRID Hydraulic Evaluation Memo.docx Page 1 of 8 April 30,2020 MEMORANDUM ANdti(sury Curvsuhilv4 Eivtiilvttics, hu. Civil Water Resources Environmental Upstream Study Umltt ' � f e Al 4 r COFC Wastewater Treatment e - Existing Low a BsnklOverllow t1 Weir Location �•� Concepti tal Lateral f I' Spill Location From ®® ?era amrty Futur® William Nadi Pkayr Park � I Site orifice Plats c , i. Cottonwood La rite,and Fossil Creek Fauns Ron ervoirInlet Ditch(FCRID) Y,orsotoolki Rd Radial Gate :� a and Lateral k Snlll Location \ fi :•r Ail - Y�'�A�I 1 - ." F Dovlmatraam Sludy Llmlt liarnh4ny Rd - _ - i�ew_.�.r• 0 750 1,500 3,000 m4fjd]4 ` FeetEk -- 2s Figure 1.Vicinity Map. FCRID Hydraulic Evaluation Memo.docx Page 2 of 8 April 30,2020 ��`lJ p •. �,r CUt1U �.ti li]f�LnN FiSi.�AS.'J +�,� 4�2�. Z. 'S, trr (+ i �'N' d, '•�►Y� O Z 16 - � (rI� a �..w•✓tr _j U jag u) � ,� �• searQ+i r .si .a''" ,,tip'^ # rr �1�.� 4 d /'�pA,.,:: �•1 � ,� �j 'fir r!° d'xsy-..th�/ �°:'`«.r�� ��,r��. •�' ���¢J� 3 LL �+. w;s Y 1 F FEB 2 5 ?Ate alMd Repo ate 5IZCI) �Z FINAL DRAINAGE AND EROSION CONTROL REPORT Rigden Farm - Filing Six Prepared for: Rigden Farm LLC c/o Wheeler Commercial 1'027 W. Horsetooth Road, Suite 200 Fort Collins, Colorado 80526 (970) 225-9305 Prepared by; JR Engineering 2620 E. Prospect Road, Suite 190 Fort Collins, Colorado 80525 (970) 491-9888 - ; Revised February 8, 2002 Revised December.5, 2001 Revised July 25, 2001 Revised March 28,2001 December 13, 2000 Job Number 9164.12 Swale to Poudre River Worksheet for Trapezoidal Channel Project Description Project File x:\3910000.all\3916412\drainage\filing6.fm2 Worksheet Swale to Poudre River Flow Element Trapezoidal Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.035 Channel Slope 0.003000 ft/ft Left Side Slope 4.000000 H : V Right Side Slope 4.000000 H : V Bottom Width 15.00 ft Discharge 134.00 cfs Results Depth 1.97 ft Flow Area 45.12 ft2 Wetted Perimeter 31.26 ft Top Width 30.77 ft Critical Depth 1.21 ft Critical Slope 0,018313 ft/ft Velocity 2.97 ft/s Velocity Head 0.14 ft Specific Energy 2.11 ft Froude Number 0.43 Flow is subcritical. Notes: Q = ASINWQ100 from SWMM 9164-PRO.out CE 9�ZV--, 03/24/01 FlowMaster v5.15 03:56:27 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203)755-1666 Page 1 of 1 Swale to Poudre River Cross Section for Trapezoidal Channel Project Description Project File x:13910000.all\3916412\drainage\filing6.fm2 Worksheet Swale to Poudre River Flow Element Trapezoidal Channel Method Manning's Formula Solve For Channel Depth Section Data Mannings Coefficient 0.035 Channel Slope 0.003000 ft/ft Depth 1.97 ft Left Side Slope 4.000000 H : V Right Side Slope 4.000000 H : V Bottom Width 15.00 ft Discharge 134.00 cfs — too 1.97 ft 1 15.00 ft V H 1 NITS 03/24/01 FlowMaster v5.15 03.56:32 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203)755-1666 Page 1 of 1 Swale to Poudre River Worksheet for Trapezoidal Channel Project Description Project File x:\3910000.all\3916412\drainage\filing6.fm2 Worksheet Swale to Poudre River Flow Element Trapezoidal Channel Method Manning's Formula Solve For Channel Depth Input Data Mannings Coefficient 0.035 Channel Slope 0,003000 ft/ft Left Side Slope 4.000000 H : V Right Side Slope 4.000000 H : V Bottom Width 15.00 ft Discharge 178.00 cfs CC> Q�dO (!�L[C \ Results Depth 2.29 ft Flow Area 55.24 ftz Wetted Perimeter 33.86 ft Top Width 33.30 ft Critical Depth 1.43 ft Critical Slope 0.017490 ft/ft Velocity 3.22 ft/s Velocity Head 0.16 ft Specific Energy 2.45 ft Froude Number 0.44 Flow is subcritical. Notes: Q = 133% of Q100 from SWMM 9164-PRO.out CEW Z1.�, 03/24/01 FloWMaster v5.15 03.52:53 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203)755-1666 Page 1 of 1 Swale to Poudre River Cross Section for Trapezoidal Channel Project Description Project File x:13910000.all\3916412\drainage\filing6.fm2 Worksheet Swale to Poudre River Flow Element Trapezoidal Channel Method Manning's Formula Solve For Channel Depth Section Data Mannings Coefficient 0,035 Channel Slope 0.003000 ft/ft Depth 2.29 ft Left Side Slope 4.000000 H : V Right Side Slope 4.000000 H : V _ Bottom Width 15.00 ft // � Discharge 178.00 cfs — i3��lp (op C�'Y{C,FS 2.29 ft 1 15.00 ft V H 1 NTS 03/24/01 FlowMaster v5.15 03'53:16 PM Haestad Methods, Inc. 37 Brookside Road Waterbury,CT 06708 (203)755-1686 Page 1 of 1 APPENDIX C Hydrologic & Hydraulic Computations Rational Method Calculations Horsetooth Road Existing Conditions Prepared By: RJJ Project: Strauss Lakes Date: 07/26/24 Basin Description: East Horsetooth Road NRCS Hydrologic Soil Rating: D Basin Area= 5.61 [acres]= 244,291 [sf] Surface Characteristics' Sub-Area Imp Runoff [acres] [%] Coefficients' asphalt,concrete 0.30 100.0 0.20 gravel 1.63 40.00 0.50 lawns,clayey soil,avg slope 2-7% 3.69 2.00 0.25 1 City of Fort Collins"Stormwater Criteria Manual",Table 3.2-2 Weighted Percent Imperviousness: I [%]= 18.29 A,= 44,669.11 [sf] Composite Runoff Coefficients: C= 0.32 Frequency Adjustment Factors(C,)z: 2-Year Cf= 1.00 10-Year Cf= 1.00 100-Year Cf= 1.25 Cz= 0.32 C10= 0.32 C1002 = 0.40 z City of Fort Collins"Stormwater Criteria Manual",Table 3.2-3 Time of Concentration: Overland Flow Time: Channelized Flow Time: L;[ft]= 42 Lt1[FT]= 1860 Lt2[FT]= 0 Si[%]= 0.10 St1[%]= 0.01 Ste[%]= 0.00 t;[min]= 20.13 Vt1[fps]= 3.20 V12[fps]= 0.00 tt1[min]= 9.69 tt2[min]= 0.00 tt[min]= 9.69 Time of Concentration: t,=t;+tt[min]= 29.82 t,(minimum)= 5 min t,[min] Rainfall Intensity3 IZ[in/hr]= 1.30 110[in/hr]= 2.21 1100[in/hr]= 4.52 3 City of Fort Collins"Stormwater Criteria Manual"Table 3.4-1 Runoff-Rational Method Equation Q2[cfs]= 2.34 Q10[cfs]= 3.97 Q100[cfs]= 10.16 °City of Fort Collins"Stormwater Criteria Manual",Equation 5-1 J:\Cottonwood Land-372\372.001.01 Strauss Lakes\Memos&Reports\Drainage\Spreadsheets\Rational Method Calcs.xlsx i .a, R F s-,i_is c_ Historic SWM M Model a____ {� • § d < \�`* Ir P>, - /�/ . y . . . . . . . iw � < .m>»2t,<° � : •y � � � � . ^ \ :& SWMM a2 Page 1 Historic SWMM Model Subcatchment Runoff Summary Total Total Total Total hnpery Pery Total Total Precip Runon Evap Infil Runoff Runoff Runoff Runoff Subcatchment in in in in in in in 10^6 gal WestSite 0.98 0.00 0.00 0.94 0.02 0.02 0.04 0.01 NorthSite 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.01 EastSite 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.05 SWMM 5.2 Page 1 Historic SWMM Model Subcatchment Runoff Summary Peak Runoff Runoff Subcatchment CFS Coeff WestSite 0.90 0.036 NorthSite 1.16 0.020 EastSite 4.92 0.018 SWMM 5.2 Page 2 Preliminary Proposed SWMM Model 06/28/2024 00:15A0 5 4, II I� I�I'I I I� I 1: d� SWMM 5.2 Page 1 Preliminary Proposed SWMM Model Subcatchment Runoff Summary Total Total Total Total Impery Pery Total Total Precip Runon Evap Infil Runoff Runoff Runoff Runoff Subcatchment in in in in in in in 10^6 gal E-1 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 E-2 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 E-3 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 E-4 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 E-5 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 WestSite 3.69 0.00 0.00 0.14 3.26 0.24 3.50 1.15 NorthSite 3.69 0.00 0.00 0.15 3.24 0.22 3.46 1.88 SWMM 5.2 Page 1 Preliminary Proposed SWMM Model Subcatchment Runoff Summary Peak Runoff Runoff Subcatchment CFS Coeff E-1 133.77 0.937 E-2 133.77 0.937 E-3 133.77 0.937 E-4 133.77 0.937 E-5 133.77 0.937 WestSite 118.88 0.946 NorthSite 127.26 0.936 SWMM 5.2 Page 2 Preliminary Proposed SWMM Model Storage Volume Summary Average Average Evaporation Exfiltration Maximum Maximum Day of Hour of Storage Volume Percent Loss Loss Volume Percent Maximum Maximum Unit 1000 ft3 Full % % 1000 ft3 Full Volume Volume CWP 231.070 46.9 0.0 0.0 473.224 96.1 0 01:38 WaterQualityP nd 19.605 92.1 0.0 0.0 21.281 100.0 0 00:32 SWMM 5.2 Page 1 Preliminary Proposed SWMM Model Storage Volume Summary Maximum Storage Outflow Unit CFS CWP 122.83 WaterQualityP nd 0.08 SWMM 5.2 Page 2 WQCV Calculations NORTH SITE Area 20.00 acres a' 1.00 (40 hours, EDB) Imperviousness 0.90 % as decimal WQCV 0.40 wat-in WQCV 0.80 ac-ft 34978 ft EAST SITE Area 99.10 acres a' 0.90 (24 hours, CWP) Imperviousness 0.90 % as decimal WQCV 0.36 wat-in WQCV 3.58 ac-ft 155984 ft WEST SITE Area 12.08 acres a' 1.00 (40 hours, WQCV Pond) Imperviousness 0.90 % as decimal WQCV 0.40 wat-in WQCV 0.485 ac-ft 21127 ft HORSETOOTH ROAD Area 5.61 acres a' 1.00 (40 hours, EDB) Imperviousness 0.95 % as decimal WQCV 0.45 wat-in WQCV 0.25 ac-ft 10929 ft 'Drain time coefficients from Table 5.4-1 of the FCSCM and Table 3-2 of the USDCM. Constructed Wetland Pond Permanent Pool Cv' 0.75 WQCV 3.58 ac-ft VP2 2.69 ac-ft 116988 W 'Sizing coefficient from MHFD Fact Sheet T-7. 2Equation RP/CWP-1 from MHFD Fact Sheet T-7. FAA Detention Sizing Major Design Storm: 100-year Horsetooth Road Area 5.61 AC 244372 SF Impervious 95% 'Runoff Coefficient 0.95 QouT 1 US Storm Duration Rainfall Intensity Inflow Volume Outflow Volume Storage Volume T 2/ 3V' 4Vo 5VS (min) (in/hr) ft3 ft3 ft3 5 9.95 15909 300 15609 10 7.72 24686 600 24086 15 6.52 31274 900 30374 20 5.60 35814 1200 34614 25 4.98 39811 1500 38311 30 4.52 43361 1800 41561 35 4.08 45663 2100 43563 40 3.74 47838 2400 45438 45 3.46 49788 2700 47088 50 3.23 51643 3000 48643 55 3.03 53290 3300 49990 60 2.86 54873 3600 51273 65 2.71 56327 3900 52427 70 2.59 57974 4200 53774 75 2.48 59477 4500 54977 80 2.38 60884 4800 56084 85 2.29 62243 5100 57143 90 2.21 63602 5400 58202 95 2.13 64705 5700 59005 100 2.06 65873 6000 59873 105 2.00 67152 6300 60852 110 1.94 68239 6600 61639 115 1.88 69134 6900 62234 120 1.84 70605 7200 63405 Modified FAA Storage Volume 63405 ft3 Modified FAA Storage Volume 1.46 ac-ft 'Runoff coefficient from table 3.2.1 in Fort Collins Stormwater Criteria Manual(FCSCM). 2Intensity from Table 3.4.1 in FCSCM. 3Calculated per equation 6-1 in FCSCM. 3Calculated per equation 6-2 in FCSCM. 3Calculated per equation 6-3 in FCSCM. FAA Detention Sizing Major Design Storm: 100-year North Site Area 20.00 AC 871200 SF Impervious 90% 'Runoff Coefficient 0.85 QouT 9 US Storm Duration Rainfall Intensity Inflow Volume Outflow Volume Storage Volume T 2/ 3V 4Vo 5vs (min) (in/hr) ft3 ft3 ft3 5 9.95 50745 2700 48045 10 7.72 78744 5400 73344 15 6.52 99756 8100 91656 20 5.60 114240 10800 103440 25 4.98 126990 13500 113490 30 4.52 138312 16200 122112 35 4.08 145656 18900 126756 40 3.74 152592 21600 130992 45 3.46 158814 24300 134514 50 3.23 164730 27000 137730 55 3.03 169983 29700 140283 60 2.86 175032 32400 142632 65 2.71 179673 35100 144573 70 2.59 184926 37800 147126 75 2.48 189720 40500 149220 80 2.38 194208 43200 151008 85 2.29 198543 45900 152643 90 2.21 202878 48600 154278 95 2.13 206397 51300 155097 100 2.06 210120 54000 156120 105 2.00 214200 56700 157500 110 1.94 217668 59400 158268 115 1.88 220524 62100 158424 120 1.84 225216 64800 160416 Modified FAA Storage Volume 160416 ft3 Modified FAA Storage Volume 3.68 ac-ft 'Runoff coefficient from table 3.2.1 in Fort Collins Stormwater Criteria Manual(FCSCM). 2Intensity from Table 3.4.1 in FCSCM. 3Calculated per equation 6-1 in FCSCM. 3Calculated per equation 6-2 in FCSCM. 3Calculated per equation 6-3 in FCSCM. Channel Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Monday,Jul 29 2024 Conveyance Swale (Basins 1) User-defined Highlighted Invert Elev (ft) = 100.00 Depth (ft) = 4.25 Slope (%) = 0.25 Q (cfs) = 133.77 N-Value = 0.053 Area (sqft) = 64.31 Velocity (ft/s) = 2.08 Calculations Wetted Perim (ft) = 35.59 Compute by: Known Q Crit Depth, Yc (ft) = 2.64 Known Q (cfs) = 133.77 Top Width (ft) = 34.50 EGL (ft) = 4.32 (Sta, El, n)-(Sta, El, n)... (0.00, 105.00)-(15.00, 102.00,0.025)-(21.00, 100.00,0.090)-(27.00, 102.00,0.090)-(42.00, 105.00,0.025) Elev (ft) Section Depth (ft) 106.00 6.00 105.00 5.00 104.00 4.00 103.00 3.00 102.00 2.00 101.00 1.00 100.00 0.00 99.00 -1.00 -5 0 5 10 15 20 25 30 35 40 45 50 Sta (ft) Channel Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Monday,Jul 8 2024 Conveyance Swale (Basins 1-2) User-defined Highlighted Invert Elev (ft) = 100.00 Depth (ft) = 5.18 Slope (%) = 0.25 Q (cfs) = 267.54 N-Value = 0.048 Area (sqft) = 100.72 Velocity (ft/s) = 2.66 Calculations Wetted Perim (ft) = 45.08 Compute by: Known Q Crit Depth, Yc (ft) = 3.41 Known Q (cfs) = 267.54 Top Width (ft) = 43.80 EGL (ft) = 5.29 (Sta, El, n)-(Sta, El, n)... (0.00, 105.75)-(18.75, 102.00,0.025)-(24.75, 100.00,0.090)-(30.75, 102.00,0.090)-(49.50, 105.75,0.025) Elev (ft) Section Depth (ft) 106.00 6.00 Nr 105.00 5.00 104.00 4.00 103.00 3.00 102.00 2.00 101.00 1.00 100.00 0.00 99.00 -1.00 -5 0 5 10 15 20 25 30 35 40 45 50 55 Sta (ft) Channel Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Monday,Jul 8 2024 Conveyance Swale (Basins 1-3) User-defined Highlighted Invert Elev (ft) = 100.00 Depth (ft) = 5.83 Slope (%) = 0.25 Q (cfs) = 401.31 N-Value = 0.045 Area (sqft) = 131.31 Velocity (ft/s) = 3.06 Calculations Wetted Perim (ft) = 51.71 Compute by: Known Q Crit Depth, Yc (ft) = 3.94 Known Q (cfs) = 401.31 Top Width (ft) = 50.30 EGL (ft) = 5.98 (Sta, El, n)-(Sta, El, n)... (0.00, 106.50)-(22.50, 102.00,0.025)-(28.50, 100.00,0.090)-(34.50, 102.00,0.090)-(57.00, 106.50,0.025) Elev (ft) Section Depth (ft) 107.00 7.00 106.00 6.00 105.00 5.00 104.00 4.00 103.00 3.00 102.00 2.00 101.00 1.00 100.00 0.00 99.00 -1.00 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Sta (ft) Channel Report Hydraflow Express Extension for Autodesk®Civil 3D®by Autodesk, Inc. Monday,Jul 29 2024 Conveyance Swale (Basins 1-4) User-defined Highlighted Invert Elev (ft) = 100.00 Depth (ft) = 6.34 Slope (%) = 0.25 Q (cfs) = 535.08 N-Value = 0.043 Area (sqft) = 158.26 Velocity (ft/s) = 3.38 Calculations Wetted Perim (ft) = 56.91 Compute by: Known Q Crit Depth, Yc (ft) = 4.37 Known Q (cfs) = 535.08 Top Width (ft) = 55.40 EGL (ft) = 6.52 (Sta, El, n)-(Sta, El, n)... (0.00, 107.00)-(25.00, 102.00,0.025)-(31.00, 100.00,0.090)-(37.00, 102.00,0.090)-(62.00, 107.00,0.025) Elev (ft) Section Depth (ft) 108.00 8.00 107.00 7.00 106.00 6.00 105.00 5.00 104.00 4.00 103.00 3.00 102.00 2.00 101.00 1.00 100.00 0.00 99.00 -1.00 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Sta (ft) APPENDIX D Drainage Plans LEGEND LEGEND CO NT. 7 PROPERTY LINE CHANNEL CENTERLINE CIVIL IZLS1)[ 1RGI S MAJOR CONTOUR — — — —5740— - FLOW DIRECTION MINOR CONTOUR — — -5736- SIGN 8308 COLORADO BLVD SUITE 200 BARBED WIRE FENCE k: SANITARY MANHOLE FIRESTONE, CO 80530 303.833.1416 CHAINLINK FENCE FLARED END SECTION WWW.CIVILRESOURCES.COM GAS LINE STORM MANHOLE / WATER LINE LIGHT POLE/UTILITY POLE X STORM SEWERSTRUCT RE / I / TREE BOXELDER DITCH I, � I TELECOM COTTONWOOD UNDERGROUND ELECTRIC DRAINAGE BASIN BOUNDARY ■ �J I LAND & FARMS LLC OVERHEAD WIRES off DRAINAGE BASIN NAME SANITARY SEWER 2-YEAR FLOW CFS ( ) A XXX xxx � �� ��' I BILL MCDOWELL ke'' MANAGING PARTNER RETAINING WALL DRAINAGE AREA (ACRES) RIGDENRESERV O R I /! `\ I / 486 8 � PO BOX 229 50.0' DITCH BOULDER CO 80306 EASEMENT f r QBjw I / / Q - - W J @MEN*, U / I . I I � 30.o' EX UTitITr '. HORSETOOTH TOOTH AD r %-� _ AG CFS Q � O DjTcH / / J ) 4875 II I Lu BpX6�06ATroNi / I 1 _ � O R ♦ _ - Iz Q Q EXISTING GROUNDWATER MONITORING WELL (TYP.) I — / �_ - - _ _ -- - EXISTING SPILL EAST / �- / SITE J I REVISIONS STRUCTURE TO FCO 00.8 4.92 f NO DESCRIPTION DATE EXisTiCFS NG Di�ERS10N- / STRUCTURE TO - i - - - - - RIDGEN RESERVOIR / 6 J, - / - __ - EXISTING FCRID FLOW CONTROL GATE �1 f NORTH' ��� i�%'� v \� � _ _ - � i / / / a / SITE p 20.291.16 O / / /� / AC. CFS 00* 711 Mu') LLJ ui r � r / ��� % / // I - - �- — �) — � �O / 4000" Q(G� L 1 FLATIRONS POND _ _ DESIGNED BY: RJJ DATE: 07/11/2024 _ ��� _ WEST - / / / w �1G/ / C ' \\ / _ _ �� / / S TE J / DRAWN BY: RJJ SCALE: 1" = 200' // / - ✓ - -- __ I ��� / �C a�� / - / / I CHECKED BY: JAB �� - �� osCFS f 1z. �� ti� / � AC.CFS -- v u H JOB NO.: 372.001.01 % - - - -- _ �> - / 0 U `- i DWG NAME:37200101HIST ODP - - 40 Ln / �! _ - —/ — \ :�1 - - — __ — J l J ✓ 'i IN FEET) -- =_ -- - C - � __ -- 1 o / / �- J M !SO4t Ne �� ,, _ HISTORIC - - J - -- - - - - - - - - - � �-..A _� � -- - - - - - , - -- � _ -- �_� Win— , — — ---- -- - _ � DRAINAGE PLAN 4 � 0 A& _ oM RIGDE/V FAR Q SHEET: InPOND 216 ti Know whats below. , k D - 1 Call before you dig. LEGEND LEGEND CO NT. PROPOSED EXISTING PROPOSED EXIXTIXG DESIGN POINT SUMMARY Design Point Description Q 100 (cfs) PROPERTY LINE - - WATER QUALITY/ DP-N1 flow to detention pond 127.26 �. FLOOD CONTROL FACILITY discharge from detention C 7 I V I L R [ S l_1 R C: F S MAJOR CONTOUR - - - -5740- - - - - - DP-N2 9 r r CONVEYANCE SWALE pond - -5736- - - - - - r r r r DP-E1 flow to swale section 1 133.77 MINOR CONTOUR - 8308 COLORADO BLVD ACCESS ROAD/TRAIL DP-E2 flow to Swale section 2 267.54 SUITE 200 BARBED WIRE FENCE FIRESTONE, CO 80530 SIGN DP-E3 flow to swale section 3 401.31 303.833.1416 CHAINLINK FENCE DP-E4 flow to swale section 4 535.08 WWW.CIVILRESOURCES.COM SANITARY MANHOLE II surface flow to CWP 133.77 GAS LINE G FLARED END SECTION DP-E6 discharge from CWP 133.23 WATER LINE W ® % DP-W1 flow to water quality pond 118.88 Q� discharge from water STORM MANHOLE g EXISTING CONTROL J STORM SEWER ST - l DP-W2 0.08 STRUCTURE FOR Q LIGHT POLE/UTILITY POLE / quality pond aoXELDER DITCH / TELECOM DP-H1 flow to detention and 5.06 ) I }�I I� discharge from detention / > 111 p ' ��� �� �� �� APPROX. LOCATION OF COTTONWOOD UNDERGROUND ELECTRIC TREE DP-H1 pond 1 �////l i POND DISCHARGE TO FCO LAND & FARMS, LLC OVERHEAD WIRES off DRAINAGE BASIN BOUNDARY / X ! SANITARY SEWER pp _ #A DESIGN POINT / / o 0 j //� , � � BILL MCDOWELL g867 I I �j , APPROX. AREA OF CONSTRUCTED MANAGING PARTNER RETAINING WALL DRAINAGE BASIN NAME / r - WETLAND POND = 4.91 AC RIGDENRESERI/OIR �/! /�� 4868 I II II PERMANENT POOL = 2.69 AC-FT PO BOX 229 50.0' DITCH f i, WQCV = 3.58 AC-FT BOULDER, CO 80306 CHANNEL CENTER LINE XX A xx 100-YEAR FLOW (CFS) EASEMENT i I 100-YR VOL. = 6.87 AC-FT TOTAL STORAGE VOL = 10.45 AC-FT FLOW DIRECTION DRAINAGE AREA (ACRES) / / � �869 � I � APPROX. LOCATION OF / I POND DISCHARGE TO FCO 62.0' MAXIMUM / / //i / _ DP - E4. SWALE TOP WIDTH Q100 = 535.08 CFS i / _ I DP - H2 Q 57.0' SWALE �� Q TOP WIDTH / �� / t / �p Q100 = 401.31CFS i �_:� � DP - E3. ; U) APPROXDETENTION AREA OF I 1 I DETENTION POND = 0.76 AC A° j l I �: wgcv = 0.25 AC-FT 49.5' SWALE / - J - - - 30.0' EX UTILITY / � _ I� I � 100-YR VOL. = 1.48 AC-FT / j EASEMENT TOTAL STORAGE VOL. = 1.73 AC-FT TOP WIDTH Q100 = 267.54 CFS / // DP - E2 O r �� �� I _ - - LL _ 19.90 133.77 I � l�� �_ L.V U AC. CFS I V HORR ADOTH O 5.615.06 LU X 11 I � / � j � � I I I I NOTE: gO RjGA / _ / Jar I - - L _r I I I I LID WILL NOT BE PROVIDED FOR _ _ J I THE HORSETOOTH ROAD BASIN. 20.0' SHARED �� / I II LID FOR ALL OTHER DRAINAGE / BASINS WILL ACCOUNT FOR THE 7r MAINTENANCE ROAD / //" - - - / E-4 \ I Q I 75/o LID REQUIREMENT. &RECREATIONAL TRAIL / / - \- �D P - E 1 - - ��-' t� 7 19.64 133.77 � I V �O I APPROX. LOCATION OF /j _ - - - Ac. cFs - // POND DISCHARGE TO /� / Y - / I EAST SITE -I \ f v RIGDEN FARM OUTFALL CHANNEL 42.0' MINIMUM / / / r I - '� SWALE TOP WIDTH //// - / NOTE. Q100 - 133.77 CFS �_ // .� . / LID WILL BE PROVIDED REGIONALLYFOR THE EAST SITE VIA THE _ - 1 CONSTRUCTED WETLAND POND. '/ / APPROX. AREA OF / /i/ jj / L DP N2DETENTION POND _ P / / �„ ` I I 100-YR VOL. = 3.68 AC-FT /// / J� r EXISTING SPILL WQCV /�i Jj rr , � - , - � _ / - - - - E-3 j � � � , \ 1 I I /// / r - - - _ - - STRUCTURE TO FCO I REVISIONS TOTAL STORAGE VOL. = 4.48 AC-FT / / / Q2O2. 133.77cFs / NO DESCRIPTION DATE EXISTING 0114f RsioN STRUCTURE TO I l RIDGEN RESERVOIR E-2 r 2036 133.77 - o r - - I I ? EXISTING FCRID AC. CFS / W - ) / / / / �� / /1 J FLOW CONTROL GATE / DP - W2, APPROX. LOCATION OF / -j `r / / I / / / POND DISCHARGE TO FCRID EXISTING GROUNDWATER MONITORING WELL / � NORTH \ \ - = ✓ y APPROX. AREA OF WATER SITE % / / 1 I ���/' ; j G / / QUALITY POND = 0.29 AC o / / / f zo.z9 1z7.z6 / ✓� ^\\ y� / \ / i 1 J o J_ \ _ - J 5(\�p�Q`^S WQCV = 0.485 AC-FT Oo AC. CFS cA� �,''/ � \X \^ / / I ` / J 1 1 ` , \ - /.C�j� r1l / IDTWILL BE PROVIDED LOCALLY `�8� / ' J / / `� / I ✓ X / / / j V) / S. / �\ \ � w /" FOR THE NORTH SITE VIA RAIN �� / / / \ - _ _ _ _ - _/ / I I ' �� / I / / / j I LD / // / GARDENS,PERMEABLE PAVERS, / / / I I _ -. - �� - �� / '�, / /. I V 1J � / ,(�'�// GRASS BUFFERS,ETC. / - _ - Q� / APPROX. LOCATION OF / ,%o STORM SEWER HEADER PIPE I �` --/,/WEST / -��� / SITE - - - \ 1z.08 11a.as DESIGNED BY: RJJ DATE: 07/11/2024 FLATIRONS POND \ - - \� - - I \� � 1- - - _ r G�� / ////// j ��X AC. CFS - - - cn / / / ? j I j �� G' / -• \\ I DRAWN BY: RJJ SCALE: 1" = 200' wI - a aJ NOTE: CHECKED BY: JAB Y _ \ O Q' / / - LID WILL BE PROVIDED LOCALLY /�/ / / / `- - r �_� _ _ r----- -1 e �>� - -�- � r\ \ �' ` / i / - FOR THE WEST SITE VIA RAIN / /.. l _ / / _ ..� •~ �X i ^ - _: - - - - _ / _ jp- �I ✓ i / / /- ,.�/ i j GARDENS,PERMEABLE PAVERS, Q / G / v ` -> % / ✓ / % J ^ \ \ i- 7 i J - _ - - _ \ _- 1- - - - - , X"/ / /"/. / C) � GRASS BUFFERS,ETC. f/ I��URTH JOB N A 372.001.01 _ �1 i -�� T- / - - _ I� �_ - -T-- - - �/ f/ i / ��;C' / 0 100 200 W NA /� / � / - - - J X_ / // / / , D G ME:372001010DP // /�--K o j N / - \ / _ �_ �\ - - - - \- i'-- � � __= / l g �� / = \ IN FEET) , J -=J/ (�r-zoo: MN 1c= - O VERA LL LERROAD DRAINAGE PL AN -- _ - • k '1L- # . oRIGDEN FARM Q SHEET: o POND 216 D - 2 � � Know whit s below. U Call before you dig.