Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS AMENDMENT TRACT B - MA210028 - SUBMITTAL DOCUMENTS - ROUND 5 - Responses05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 0 1 T I T L E S H E E T . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 5 A M PL O T D A T E : 01 TI T L E S H E E T 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 291 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH FINAL DEVELOPMENT PLAN VICINITY MAP SCALE: 1"=1000' RIDGEWOOD HILLS FIFTH FILING - MALEGAL DESCRIPTION A PARCEL OF LAND LOCATED IN SECTION 14, T.6N., R.69W., OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO AND BEING PARTICULARLY DESCRIBED AS FOLLOWS: TRACT B OF RIDGEWOOD HILLS P.U.D., FOURTH FILING ACCORDING TO THE RECORDED PLAT THEREOF AS RECORDED BY THE LARIMER COUNTY CLERK AND RECORDER ON JANUARY 20, 2017 AT RECEPTION NO. 20170004364. . . . (WHICH ABOVE DESCRIBED TRACT CONTAINS 5.195 ACRES, MORE OR LESS) INDEX TO DRAWINGS MAY 30, 2023 BEING A REPLAT OF TRACT B, RIDGEWOOD HILLS FOURTH FILING, SITUATED IN THE SOUTHEAST QUARTER OF SECTION 14, TOWNSHIP 6 NORTH, RANGE 69 WEST, OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. FINAL UTILITY PLANS FOR SUPPLEMENTAL GENERAL NOTES LEGEND ALL SANITARY SEWER LINE CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE DATE OF CONSTRUCTION. ALL WATER LINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS - LOVELAND WATER DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE DATE OF CONSTRUCTION. REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALL ON THE FIRE LINE RISER AND DOMESTIC WATER SERVICES. ALL SANITARY SEWER LINE CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT COLLINS SANITATION DISTRICT STANDARDS AND SPECIFICATIONS CURRENT TO THE DATE OF CONSTRUCTION. SEE SHEET 3 FOR THE LARIMER COUNTY URBAN AREA STREET STANDARDS STANDARD GENERAL NOTES AND STANDARD CONSTRUCTION NOTES. LIMITS OF STREET CUTS SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS ARE TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. THE FORT COLLINS - LOVELAND WATER DISTRICT SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. THE PROPERTY OWNER WILL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL ONSITE AND OFFSITE DRAINAGE FACILITIES ASSOCIATED WITH THIS PROJECT THAT ARE OUTSIDE THE PUBLIC RIGHT OF WAY. THIS INCLUDES ALL TRACTS AND PRIVATE DRIVES. A DRAINAGE AND EROSION CONTROL REPORT HAS BEEN PREPARED SPECIFICALLY FOR RIDGEWOOD HILLS. ALL RECOMMENDATIONS INCLUDED IN SAID REPORT SHALL BE CONSIDERED A PART OF THESE GENERAL NOTES AND SPECIFICATIONS AND SHALL BE FOLLOWED DURING CONSTRUCTION. ALL SITE WORK CONSTRUCTION MUST CONFORM TO ADA (AMERICAN DISABILITIES ACT) REQUIREMENTS FOR HANDICAP ACCESS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. CONTRACTOR AND ALL SUBCONTRACTORS TO THOROUGHLY FAMILIARIZE THEMSELVES WITH THESE DOCUMENTS. ALL STORM DRAIN PIPES SHALL BE CLASS III REINFORCED CONCRETE PIPE (RCP) WITH R4 JOINTS MEETING THE REQUIREMENTS OF ASTM STANDARD SPECIFICATION C443, LATEST VERSION, UNLESS OTHERWISE SPECIFIED. PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED IRRIGATION LINE WITH METER PROPOSED ELECTRIC LINE PROJECT DATUM THE ORIGINAL GROUND SURVEY OF THE SITE OF THIS PROJECT WAS REFERENCED TO TWO CITY OF FORT COLLINS VERTICAL CONTROL BENCH MARKS, INFORMATION FOR WHICH IS PRESENTED BELOW. AT THE TIME OF THE SURVEY, THE PUBLISHED ELEVATIONS OF THE REFERENCE BENCHMARKS WERE BASED ON THE NGVD29 UNADJUSTED DATUM. CONSEQUENTLY, THE DESIGN OF THE SITE IMPROVEMENTS, AND ALL THE VERTICAL INFORMATION (GROUND CONTOURS, SPOT ELEVATIONS, PIPE AND APPURTENANCE INVERT ELEVATIONS, ETC.) PRESENTED ON THE PROJECT DRAWINGS ARE ALSO BASED ON THE NGVD29 UNADJUSTED DATUM. SHOULD IT BECOME NECESSARY TO CORRELATE INFORMATION FROM THE DESIGN/CONSTRUCTION DRAWINGS FOR THIS PROJECT, OR ANY AS-BUILT PHYSICAL PROJECT IMPROVEMENTS, TO THE NAVD88 DATUM, THE APPROPRIATE ELEVATION CONVERSION IS +3.19 FT. (I.E., ADD 3.19 FT TO THE DESIGN OR AS-BUILT ELEVATIONS, TO CONVERT THOSE TO AN ELEVATION BASED ON THE NAVD88 DATUM). BENCHMARK #1: EAST SIDE OF COLLEGE AVE, APPROXIMATELY 190' NORTH OF TRIANGLE DR., ON TOP OF THE S.E. CORNER OF AN INLET ELEVATION: 5018.8 FT (NGVD29 UNADJUSTED), 5021.99 FT (NAVD88) BENCHMARK #2: AZIMUTH MARK (3¼” ALUMINUM CAP) ON THE NORTH SIDE OF TRILBY RD., ½ MILE WEST OF COLLEGE AVE., AT THE SOUTHWEST CORNER OF 508 W. TRILBY RD., (GOOD SAMARITAN RETIREMENT CENTER), ALSO 5.5 FT WEST OF A POWER POLE AND 24.5 FT. SOUTH OF A WOOD FENCE. ELEVATION: 5090.58 FT (NGVD29 UNADJUSTED), 5093.77 FT (NAVD88) All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins-Loveland Water District and the South Fort Collins Sanitation District. District Engineer Date FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT SURVEYOR: ENGINEER: PLANNER: OWNER/APPLICANT: APPROVED: City Engineer,Approved Sheets Date APPROVED: Water & Wastewater Utility,Approved Sheets Date APPROVED: Stormwater Utility,Approved Sheets Date APPROVED: Park Planning and Development,Approved Sheets Date APPROVED: Traffic Operations,Approved Sheets Date APPROVED: Environmental Planner,Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 PROPOSED GAS LINE EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE ROAD OR DRIVE AISLE CENTERLINE BUILDING SETBACK LINE EASEMENT LINE BOUNDARY LINE PROPOSED CONTOUR PROPOSED INDEX CONTOUR Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 0 2 G E N E R A L N O T E S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 5 A M PL O T D A T E : 02 GE N E R A L N O T E S MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 292 CONSTRUCTION NOTES A. STANDARD GRADING AND EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES THE EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. THERE SHALL BE NO EARTH DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. ALL REQUIRED PERIMETER SILT AND CONSTRUCTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITIES (STOCKPILING, STRIPPING, GRADING, ETC.). ALL OTHER REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. AT ALL TIMES DURING CONSTRUCTION, THE DEVELOPER SHALL BE RESPONSIBLE FOR PREVENTING AND CONTROLLING ON-SITE EROSION INCLUDING KEEPING THE PROPERTY SUFFICIENTLY WATERED SO AS TO MINIMIZE WIND BLOWN SEDIMENT. THE DEVELOPER SHALL ALSO BE RESPONSIBLE FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL FACILITIES SHOWN TO THEM. PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA(S) REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATION, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL BMP'S ARE INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS-OF-WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITIES FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE CITY OF FORT COLLINS. IN ORDER TO MINIMIZE EROSION POTENTIAL, ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES SHALL: A. BE INSPECTED AT A MINIMUM OF EVERY TWO (2) WEEKS AND AFTER EACH SIGNIFICANT STORM EVENT AND REPAIRED OR RECONSTRUCTED AS NECESSARY IN ORDER TO ENSURE THE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. B. REMAIN IN PLACE UNTIL SUCH TIME AS ALL THE SURROUNDING DISTURBED AREAS ARE SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. C. BE REMOVED AFTER THE SITE HAS BEEN SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. WHEN TEMPORARY EROSION CONTROL MEASURES ARE REMOVED, THE DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEAN UP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM ALL DRAINAGE INFRASTRUCTURE AND OTHER PUBLIC FACILITIES. THE CONTRACTOR SHALL CLEAN UP ANY INADVERTENT DEPOSITED MATERIAL IMMEDIATELY AND MAKE SURE STREETS ARE FREE OF ALL MATERIALS BY THE END OF EACH WORKING DAY. ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY WATERS OF THE UNITED STATES. NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER THIRTY (30) DAYS SHALL BE SEEDED AND MULCHED. THE STORMWATER VOLUME CAPACITY OF DETENTION PONDS WILL BE RESTORED AND STORM SEWER LINES WILL BE CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER TO THE CITY OF FORT COLLINS OR HOMEOWNERS ASSOCIATION (HOA). CITY ORDINANCE AND COLORADO DISCHARGE PERMIT SYSTEM (CDPS) REQUIREMENTS MAKE IT UNLAWFUL TO DISCHARGE OR ALLOW THE DISCHARGE OF ANY POLLUTANT OR CONTAMINATED WATER FROM CONSTRUCTION SITES. POLLUTANTS INCLUDE, BUT ARE NOT LIMITED TO DISCARDED BUILDINGS MATERIALS, CONCRETE TRUCK WASHOUT, CHEMICALS, OIL AND GAS PRODUCTS, LITTER, AND SANITARY WASTE. THE DEVELOPER SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. A DESIGNATED AREA SHALL BE PROVIDED ON SITE FOR CONCRETE TRUCK CHUTE WASHOUT. THE AREA SHALL BE CONSTRUCTED SO AS TO CONTAIN WASHOUT MATERIAL AND LOCATED AT LEAST FIFTY (50) FEET AWAY FROM ANY WATERWAY DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION ACTIVITIES THE CONCRETE WASHOUT MATERIAL WILL BE REMOVED AND PROPERLY DISPOSED OF PRIOR TO THE AREA BEING RESTORED. CONDITIONS IN THE FIELD MAY WARRANT EROSION CONTROL MEASURES IN ADDITION TO WHAT IS SHOWN ON THESE PLANS. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AS DIRECTED BY THE CITY OF FORT COLLINS. ALL VEHICLE TRACKING CONTROL PAD SHALL BE INSTALLED WHEN NEEDED FOR CONSTRUCTION EQUIPMENT, INCLUDING BUT NOT LIMITED TO PERSONAL VEHICLES EXITING EXISTING ROADWAYS. NO EARTHEN MATERIALS, I.E. STONE, DIRT, ETC. SHALL BE PLACED IN THE CURB AND GUTTER OR ROADWAY AS A RAMP TO ACCESS TEMPORARY STOCKPILES, STAGING AREAS, CONSTRUCTION MATERIALS, CONCRETE WASHOUT AREAS, AND/OR BUILDING SITES. B. STREET IMPROVEMENTS NOTES: 1. ALL STREET CONSTRUCTION IS SUBJECT TO THE GENERAL NOTES ON THESE PLANS AS WELL AS THE STREET IMPROVEMENTS NOTES LISTED HERE. 2. A PAVING SECTION DESIGN, SIGNED AND STAMPED BY A COLORADO LICENSED TRAFFIC ENGINEER, MUST BE SUBMITTED TO THE CITY OF FORT COLLINS TRAFFIC ENGINEER FOR APPROVAL, PRIOR TO ANY STREET CONSTRUCTION ACTIVITY, (FULL DEPTH ASPHALT SECTIONS ARE NOT PERMITTED AT A DEPTH GREATER THAN 8 INCHES OF ASPHALT). THE JOB MIX SHALL BE SUBMITTED FOR APPROVAL PRIOR TO PLACEMENT OF ANY ASPHALT. 2. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BY SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BY SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. E. WATERLINE NOTES: 1. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITY DEPARTMENT. F. SEWER MAIN NOTES AND SPECIFICATIONS: 1. SANITARY SEWER MAIN CONSTRUCTION SHALL CONFORM TO THE CITY OF FORT COLLINS' MOST RECENT SANITARY SEWER SPECIFICATIONS. A COPY OF THE SPECIFICATIONS MAY BE OBTAINED FROM THE CITY OF FORT COLLINS WATER/WASTEWATER UTILITY DEPARTMENT AT 700 NORTH WOOD STREET IN FORT COLLINS. 2. SANITARY SEWER PIPE MATERIAL SPECIFICATIONS ARE AS FOLLOWS: A. POLYVINYL CHLORIDE PIPE (PVC) - ALL PVC SEWER PIPE SHALL BE UNPLASTICIZED POLYVINYL CHLORIDE PLASTIC GRAVITY SEWER PIPE "J-M RING-TITE PVC SEWER", "CERTAIN TEED FLUID-TITE PVC GRAVITY SEWER PIPE", OR APPROVED EQUAL WITH INTEGRAL WALL BELL AND SPIGOT JOINTS. PIPE SHALL BE MADE FROM MATERIALS CONFORMING TO ASTM D1784. THE PIPE SHALL BE SUITABLE FOR USE AS A GRAVITY SEWER CONDUIT WITH PROVISIONS MADE FOR CONTRACTION AND EXPANSION AT EACH JOINT WITH A RUBBER RING. ALL GRAVITY SEWER PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF ASTM D3034 AND HAVE A STANDARD DIMENSION RATIO (SDR) OF 35 OR LESS. THE MINIMUM PIPE STIFFNESS AT 5% DEFLECTION SHALL BE 46 PSI WHEN TESTED IN ACCORDANCE WITH ASTM D24212. 3. ALL SEWER LINES SHALL BE TESTED BY THE CONTRACTOR FOR WATER TIGHTNESS PRIOR TO BEING PLACED INTO SERVICE. ALL SERVICE CONNECTIONS SHALL BE COMPLETED PRIOR TO TESTING. TESTING SHALL BE DONE BY AIR PRESSURE TESTING IN ACCORDANCE WITH THE CITY'S SPECIFICATIONS. IF ANY LEAKS ARE DISCOVERED THEY SHALL BE LOCATED AND REPAIRED AT THE CONTRACTOR'S EXPENSE AND THE LINE RE-TESTED. ALL TESTING SHALL BE OBSERVED BY THE CITY OF FORT COLLINS INSPECTOR. 4. DISTANCES SHOWN FOR SANITARY SEWER ARE THE HORIZONTAL DISTANCES FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. THEREFORE, DISTANCES SHOWN ON THE PLANS ARE APPROXIMATE AND COULD VARY DUE TO VERTICAL ALIGNMENT AND MANHOLE WIDTHS. 5. SANITARY SEWER SERVICE WYES SHALL BE LOCATED A MINIMUM OF 10 FEET FROM ANY WATER SERVICE. 6. RIM ELEVATIONS SHOWN ARE APPROXIMATED ONLY AND ARE NOT TO BE TAKEN AS FINAL ELEVATIONS. THE CONTRACTOR SHALL USE PRE CAST CONCRETE ADJUSTMENT RINGS TO ADJUST THE MANHOLE FRAME TO MATCH THE FINISHED STREET SURFACE, SUCH THAT THERE ARE NO MORE THAN SIXTEEN (16) INCHES FROM FINISHED GRADE TO THE TOP OF THE CONE SECTION. 7. MANHOLE COVERS SHALL BE ALIGNED TO PROVIDE A MINIMUM OF THREE (3) FEET CLEARANCE BETWEEN THE MANHOLE RING AND THE LIP OF GUTTER. 8. ALL EXISTING AND PROPOSED MANHOLE COVERS SHALL BE ADJUSTED TO 1/4 INCH BELOW THE FINISHED STREET SURFACE. 9. THE CONTRACTOR SHALL VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF ALL POINTS OF CONNECTION AND UTILITY CROSSINGS PRIOR TO INSTALLING ANY SEWER MAIN PIPE. IF A DESIGN MODIFICATION IS REQUIRED IT SHALL BE COORDINATED WITH THE ENGINEER AND APPROVED BY THE CITY OF FORT COLLINS. 10. THE CONTRACTOR SHALL CONSTRUCT THE SEWER SERVICES TO THE BACK OF THE UTILITY EASEMENT AND SHALL MARK THE LOCATION OF THE END OF THE SERVICE WITH A 4" X 4" WOOD POST EXTENDING FROM THE SANITARY SEWER SERVICE TO TWO (2) FOOT ABOVE FINISHED GRADE. 11. THE CONTRACTOR SHALL VACUUM TEST ALL SANITARY SEWER MANHOLES PRIOR TO ACCEPTANCE. 12. OUTSIDE DROP OF DROP MANHOLES SHALL BE ENCASED IN CONCRETE PER CITY'S REQUIREMENTS. 13. ALL FOUR INCH (4") SANITARY SEWER LATERALS SHALL BE INSTALLED AT A POSITIVE GRADE OF 2.0% (1/4" PER FOOT) FROM THEIR CONNECTION TO THE SANITARY SEWER MAIN TOWARDS THE PROPOSED STRUCTURE. THIS GRADE SHALL BE HELD TO ACHIEVE THE MAXIMUM DEPTH POSSIBLE FOR THE SANITARY SEWER LATERAL AT THE BUILDING FOUNDATION. A DECREASE OR FLATTENING OF THE GRADE SHALL NOT BE ALLOWED. AN INCREASE OR STEEPENING OF THE GRADE MAY BE ALLOWED IN CERTAIN SITUATIONS ONLY UPON APPROVAL OF THE ENGINEER. 3. WHERE PROPOSED PAVING ADJOINS EXISTING ASPHALT, THE EXISTING ASPHALT SHALL BE SAW CUT, A MINIMUM DISTANCE OF 12 INCHES FROM THE EXISTING EDGE, TO CREATE A CLEAN CONSTRUCTION JOINT. THE DEVELOPER SHALL BE REQUIRED TO REMOVE EXISTING PAVEMENT TO A DISTANCE WHERE A CLEAN CONSTRUCTION JOINT CAN BE MADE. WHEEL CUTS SHALL NOT BE ALLOWED UNLESS APPROVED BY THE CITY OF FORT COLLINS ENGINEER. 4. STREET SUBGRADES SHALL BE SCARIFIED THE TOP 12 INCHES AND RE-COMPACTED PRIOR TO SUBBASE INSTALLATION. NO BASE MATERIAL SHALL BE LAID UNTIL THE SUBGRADE HAS BEEN INSPECTED AND APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. 5. VALVE BOXES AND MANHOLES ARE TO BE BROUGHT UP TO GRADE AT THE TIME OF PAVEMENT PLACEMENT OR OVERLAY. VALVE BOX ADJUSTING RINGS ARE NOT ALLOWED. 6. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BE DOCUMENTED BY THE INSPECTOR BEFORE ANY CUTS ARE MADE. CUTTING AND PATCHING SHALL BE DONE IN CONFORMANCE WITH CHAPTER 25, RECONSTRUCTION AND REPAIR. THE FINISHED PATCH SHALL BLEND SMOOTHLY INTO THE EXISTING SURFACE. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE CITY OF FORT COLLINS ENGINEER. ALL OVERLAY WORK SHALL BE COORDINATED WITH ADJACENT LANDOWNERS SUCH THAT FUTURE PROJECTS DO NOT CUT THE NEW ASPHALT OVERLAY WORK. 7. ALL TRAFFIC CONTROL DEVICES SHALL BE IN CONFORMANCE WITH THESE PLANS OR AS OTHERWISE SPECIFIED IN M.U.T.C.D. (INCLUDING COLORADO SUPPLEMENT) AND AS PER THE RIGHT-OF-WAY WORK PERMIT TRAFFIC CONTROL PLAN. 8. THE DEVELOPER IS REQUIRED TO PERFORM A GUTTER WATER FLOW TEST IN THE PRESENCE OF THE CITY OF FORT COLLINS INSPECTOR AND PRIOR TO INSTALLATION OF ASPHALT. GUTTERS THAT HOLD MORE THAN ¼ INCH DEEP OR 5 FEET LONGITUDINALLY, OF WATER, SHALL BE COMPLETELY REMOVED AND RECONSTRUCTED TO DRAIN PROPERLY. 9. PRIOR TO PLACEMENT OF H.B.P. OR CONCRETE WITHIN THE STREET AND AFTER MOISTURE/DENSITY TESTS HAVE BEEN TAKEN ON THE SUBGRADE MATERIAL (WHEN A FULL DEPTH SECTION IS PROPOSED) OR ON THE SUBGRADE AND BASE MATERIAL (WHEN A COMPOSITE SECTION IS PROPOSED), A MECHANICAL "PROOF ROLL" WILL BE REQUIRED. THE ENTIRE SUBGRADE AND/OR BASE MATERIAL SHALL BE ROLLED WITH A HEAVILY LOADED VEHICLE HAVING A TOTAL GVW OF NOT LESS THAN 50,000 LBS. AND A SINGLE AXLE WEIGHT OF AT LEAST 18,000 LBS. WITH PNEUMATIC TIRES INFLATED TO NOT LESS THAN 90 P.S.I.G. "PROOF ROLL" VEHICLES SHALL NOT TRAVEL AT SPEEDS GREATER THAN 3 M.P.H. ANY PORTION OF THE SUBGRADE OR BASE MATERIAL WHICH EXHIBITS EXCESSIVE PUMPING OR DEFORMATION, AS DETERMINED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER, SHALL BE REWORKED, REPLACED OR OTHERWISE MODIFIED TO FORM A SMOOTH, NON-YIELDING SURFACE. THE CITY OF FORT COLLINS ENGINEER SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO THE "PROOF ROLL." ALL "PROOF ROLLS" SHALL BE PREFORMED IN THE PRESENCE OF AN INSPECTOR. C. TRAFFIC SIGNS AND PAVEMENT MARKING CONSTRUCTION NOTES: 1. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. 2. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. 3. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. 4. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. 5. ALL LANE LINES FOR CONCRETE PAVEMENT SHOULD BE EPOXY PAINT. 6. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMENT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. 7. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. 8. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 9. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. 10. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. 11. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. 12. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 13. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 14. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD, THE CITY OF FORT COLLINS TRAFFIC ENGINEER RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS TRAFFIC ENGINEER DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). 15. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. D. STORM DRAINAGE NOTES: 1. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 0 3 G E N E R A L N O T E S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 6 A M PL O T D A T E : 03 GE N E R A L N O T E S MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 293 GENERAL NOTES AS ADOPTED FROM LARIMER COUNTY URBAN AREA STREET STANDARDS APPENDIX E 1. ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEED THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LARIMER COUNTY URBAN AREA STREET STANDARDS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE MOST RESTRICTIVE STANDARD SHALL APPLY. ALL WORK SHALL BE INSPECTED AND APPROVED BY THE CITY OF FORT COLLINS. 2. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 3. THESE PUBLIC IMPROVEMENT CONSTRUCTION PLANS SHALL BE VALID FOR A PERIOD OF THREE YEARS FROM THE DATE OF APPROVAL BY THE CITY OF FORT COLLINS ENGINEER. USE OF THESE PLANS AFTER THE EXPIRATION DATE WILL REQUIRE A NEW REVIEW AND APPROVAL PROCESS BY THE CITY OF FORT COLLINS PRIOR TO COMMENCEMENT OF ANY WORK SHOWN IN THESE PLANS. 4. THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBY AFFIRM RESPONSIBILITY TO THE CITY OF FORT COLLINS, AS BENEFICIARY OF SAID ENGINEER'S WORK, FOR ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE CITY OF FORT COLLINS ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCH RESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLD HARMLESS AND INDEMNIFY THE CITY OF FORT COLLINS, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINST ALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINED IN THESE PLANS. 5. ALL SANITARY SEWER AND WATER LINE CONSTRUCTION AND ALL POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL CONFORM TO THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE CITY OF FORT COLLINS ENGINEER. 6. THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK BEFORE COMMENCING NEW CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR UNKNOWN UNDERGROUND UTILITIES. 7. THE ENGINEER SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT 1-800-922-1987, AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING EXCAVATION OR GRADING, TO HAVE ALL REGISTERED UTILITY LOCATIONS MARKED. OTHER UNREGISTERED UTILITY ENTITIES (I.E. DITCH/IRRIGATION COMPANY) ARE TO BE LOCATED BY CONTACTING THE RESPECTIVE REPRESENTATIVE. UTILITY SERVICE LATERALS ARE ALSO TO BE LOCATED PRIOR TO BEGINNING EXCAVATION OR GRADING. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 8. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES DURING CONSTRUCTION AND FOR COORDINATING WITH THE APPROPRIATE UTILITY COMPANY FOR ANY UTILITY CROSSINGS REQUIRED. 9. IF A CONFLICT EXISTS BETWEEN EXISTING AND PROPOSED UTILITIES AND/OR A DESIGN MODIFICATION IS REQUIRED, THE DEVELOPER SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGN. DESIGN MODIFICATION(S) MUST BE APPROVED BY THE CITY OF FORT COLLINS PRIOR TO BEGINNING CONSTRUCTION. 10. THE DEVELOPER SHALL COORDINATE AND COOPERATE WITH THE CITY OF FORT COLLINS, AND ALL UTILITY COMPANIES INVOLVED, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH A MINIMUM DISRUPTION OF SERVICE. THE DEVELOPER SHALL BE RESPONSIBLE FOR CONTACTING, IN ADVANCE, ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE AS WELL AS THE UTILITY COMPANIES. 11. NO WORK MAY COMMENCE WITHIN ANY PUBLIC STORM WATER, SANITARY SEWER OR POTABLE WATER SYSTEM UNTIL THE DEVELOPER NOTIFIES THE UTILITY PROVIDER. NOTIFICATION SHALL BE A MINIMUM OF 2 WORKING DAYS PRIOR TO COMMENCEMENT OF ANY WORK. AT THE DISCRETION OF THE WATER UTILITY PROVIDER, A PRE-CONSTRUCTION MEETING MAY BE REQUIRED PRIOR TO COMMENCEMENT OF ANY WORK. 12. THE DEVELOPER SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZE POTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BE CONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES. 13. THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESS OTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY. 14. A STATE CONSTRUCTION DEWATERING WASTEWATER DISCHARGE PERMIT IS REQUIRED IF DEWATERING IS REQUIRED IN ORDER TO INSTALL UTILITIES OR WATER IS DISCHARGED INTO A STORM SEWER, CHANNEL, IRRIGATION DITCH OR ANY WATERS OF THE UNITED STATES. 15. THE DEVELOPER SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORM WATER DISCHARGE (CONTACT COLORADO DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION, (303) 692-3590), THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN. 16. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNER(S). 17. PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THE DRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BE SUBMITTED TO AND APPROVED BY THE STORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT. 18. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THIS DEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING FROM GROUNDWATER FLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS SUCH DAMAGE OR INJURIES ARE SUSTAINED AS A RESULT OF THE CITY OF FORT COLLINS FAILURE TO PROPERLY MAINTAIN ITS WATER, WASTEWATER, AND/OR STORM DRAINAGE FACILITIES IN THE DEVELOPMENT. 19. TEMPORARY EROSION CONTROL DURING CONSTRUCTION SHALL BE PROVIDED AS SHOWN ON THE EROSION CONTROL PLAN. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE DEVELOPER, UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS IS STABILIZED WITH HARD SURFACE OR LANDSCAPING. 20. THE DEVELOPER SHALL BE RESPONSIBLE FOR INSURING THAT NO MUD OR DEBRIS SHALL BE TRACKED ONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY AN APPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.) OR AS APPROVED BY THE CITY OF FORT COLLINS STREET INSPECTOR. 21. NO WORK MAY COMMENCE WITHIN ANY IMPROVED OR UNIMPROVED PUBLIC RIGHT-OF-WAY UNTIL A RIGHT-OF-WAY PERMIT OR DEVELOPMENT CONSTRUCTION PERMIT IS OBTAINED, IF APPLICABLE. 22. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR ALL APPLICABLE AGENCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL NOTIFY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR (FORT COLLINS - 221-6605) AND THE CITY OF FORT COLLINS EROSION CONTROL INSPECTOR (FORT COLLINS - 221-6700) AT LEAST 2 WORKING DAYS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY, OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. IF THE CITY OF FORT COLLINS ENGINEER IS NOT AVAILABLE AFTER PROPER NOTICE OF CONSTRUCTION ACTIVITY HAS BEEN PROVIDED, THE DEVELOPER MAY COMMENCE WORK IN THE ENGINEERS ABSENCE. HOWEVER, THE CITY OF FORT COLLINS RESERVES THE RIGHT NOT TO ACCEPT THE IMPROVEMENT IF SUBSEQUENT TESTING REVEALS AN IMPROPER INSTALLATION. 23. THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTS WITHIN THE PUBLIC RIGHT-OF-WAY AFTER RIGHT OF WAY GRADING AND ALL UTILITY TRENCH WORK IS COMPLETE AND PRIOR TO THE PLACEMENT OF CURB, GUTTER, SIDEWALK AND PAVEMENT. IF THE FINAL SOILS/PAVEMENT DESIGN REPORT DOES NOT CORRESPOND WITH THE RESULTS OF THE ORIGINAL GEOTECHNICAL REPORT, THE DEVELOPER SHALL BE RESPONSIBLE FOR A RE-DESIGN OF THE SUBJECT PAVEMENT SECTION OR, THE DEVELOPER MAY USE THE CITY OF FORT COLLINS'S DEFAULT PAVEMENT THICKNESS SECTION(S). REGARDLESS OF THE OPTION USED, ALL FINAL SOILS/PAVEMENT DESIGN REPORTS SHALL BE PREPARED BY A LICENSED PROFESSIONAL ENGINEER. THE FINAL REPORT SHALL BE SUBMITTED TO THE INSPECTOR A MINIMUM OF 10 WORKING DAYS PRIOR TO PLACEMENT OF BASE AND ASPHALT. PLACEMENT OF CURB, GUTTER, SIDEWALK, BASE AND ASPHALT SHALL NOT OCCUR UNTIL THE CITY OF FORT COLLINS ENGINEER APPROVES THE FINAL REPORT. 24. THE CONTRACTOR SHALL HIRE A LICENSED ENGINEER OR LAND SURVEYOR TO SURVEY THE CONSTRUCTED ELEVATIONS OF THE STREET SUBGRADE AND THE GUTTER FLOWLINE AT ALL INTERSECTIONS, INLETS, AND OTHER LOCATIONS REQUESTED BY THE CITY OF FORT COLLINS INSPECTOR. THE ENGINEER OR SURVEYOR MUST CERTIFY IN A LETTER TO THE CITY OF FORT COLLINS THAT THESE ELEVATIONS CONFORM TO THE APPROVED PLANS AND SPECIFICATIONS. ANY DEVIATIONS SHALL BE NOTED IN THE LETTER AND THEN RESOLVED WITH THE CITY OF FORT COLLINS BEFORE INSTALLATION OF BASE COURSE OR ASPHALT WILL BE ALLOWED ON THE STREETS. 25. ALL UTILITY INSTALLATIONS WITHIN OR ACROSS THE ROADBED OF NEW RESIDENTIAL ROADS MUST BE COMPLETED PRIOR TO THE FINAL STAGES OF ROAD CONSTRUCTION. FOR THE PURPOSES OF THESE STANDARDS, ANY WORK EXCEPT C/G ABOVE THE SUBGRADE IS CONSIDERED FINAL STAGE WORK. ALL SERVICE LINES MUST BE STUBBED TO THE PROPERTY LINES AND MARKED SO AS TO REDUCE THE EXCAVATION NECESSARY FOR BUILDING CONNECTIONS. 26. PORTIONS OF LARIMER COUNTY ARE WITHIN OVERLAY DISTRICTS. THE LARIMER COUNTY FLOODPLAIN RESOLUTION SHOULD BE REFERRED TO FOR ADDITIONAL CRITERIA FOR ROADS WITHIN THESE DISTRICTS. 27. ALL ROAD CONSTRUCTION IN AREAS DESIGNATED AS WILD FIRE HAZARD AREAS SHALL BE DONE IN ACCORDANCE WITH THE CONSTRUCTION CRITERIA AS ESTABLISHED IN THE WILD FIRE HAZARD AREA MITIGATION REGULATIONS IN FORCE AT THE TIME OF FINAL PLAT APPROVAL. 28. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR SHALL CONTACT THE CITY OF FORT COLLINS FORESTER TO SCHEDULE A SITE INSPECTION FOR ANY TREE REMOVAL REQUIRING A PERMIT. 29. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO, EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. REFER TO OSHA PUBLICATION 2226, EXCAVATING AND TRENCHING. 30. THE DEVELOPER SHALL SUBMIT A CONSTRUCTION TRAFFIC CONTROL PLAN, IN ACCORDANCE WITH MUTCD, TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY (CITY OF FORT COLLINS, COUNTY, OR STATE), FOR APPROVAL, PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN, OR AFFECTING, THE RIGHT-OF-WAY. THE DEVELOPER SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY THE CONSTRUCTION ACTIVITIES. 31. PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION THAT WILL AFFECT TRAFFIC SIGNS OF ANY TYPE, THE CONTRACTOR SHALL CONTACT CITY OF FORT COLLINS TRAFFIC OPERATIONS DEPARTMENT, WHO WILL TEMPORARILY REMOVE OR RELOCATE THE SIGN AT NO COST TO THE CONTRACTOR; HOWEVER, IF THE CONTRACTOR MOVES THE TRAFFIC SIGN THEN THE CONTRACTOR WILL BE CHARGED FOR THE LABOR, MATERIALS AND EQUIPMENT TO REINSTALL THE SIGN AS NEEDED. 32. THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR THE INITIAL INSTALLATION OF TRAFFIC SIGNING AND STRIPING FOR THE DEVELOPMENT RELATED TO THE DEVELOPMENT'S LOCAL STREET OPERATIONS. IN ADDITION, THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR TRAFFIC SIGNING AND STRIPING RELATED TO DIRECTING TRAFFIC ACCESS TO AND FROM THE DEVELOPMENT. 33. THERE SHALL BE NO SITE CONSTRUCTION ACTIVITIES ON SATURDAYS, UNLESS SPECIFICALLY APPROVED BY THE CITY OF FORT COLLINS ENGINEER, AND NO SITE CONSTRUCTION ACTIVITIES ON SUNDAYS OR HOLIDAYS, UNLESS THERE IS PRIOR WRITTEN APPROVAL BY THE CITY OF FORT COLLINS. 34. THE DEVELOPER IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BE PROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE. 35. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENT DIMENSIONS ARE NOT SHOWN, CONTACT THE DESIGNER FOR CLARIFICATION, AND ANNOTATE THE DIMENSION ON THE AS-BUILT RECORD DRAWINGS. 36. THE DEVELOPER SHALL HAVE, ONSITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB. 37. IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE DEVELOPER SHALL CONTACT THE DESIGNER AND THE CITY OF FORT COLLINS ENGINEER IMMEDIATELY. 38. THE DEVELOPER SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORD DRAWINGS KEPT ON THE CONSTRUCTION SITE, AND AVAILABLE TO THE CITY OF FORT COLLINS'S INSPECTOR AT ALL TIMES. UPON COMPLETION OF THE WORK, THE CONTRACTOR(S) SHALL SUBMIT RECORD DRAWINGS TO THE CITY OF FORT COLLINS ENGINEER. 39. PROJECT BENCHMARKS: SEE INFORMATION PRESENTED UNDER THE HEADING “PROJECT DATUM” ON THE TITLE SHEET. 40. ALL STATIONING IS BASED ON CENTERLINE OF ROADWAYS EXCEPT AT FLOWLINE PROFILES OR UNLESS OTHERWISE NOTED. 41. DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS EXISTING FENCES, TREES, STREETS, SIDEWALKS, CURBS AND GUTTERS, LANDSCAPING, STRUCTURES, AND IMPROVEMENTS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER'S EXPENSE, UNLESS OTHERWISE INDICATED ON THESE PLANS, PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 42. WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE ORIGINAL STREET CONDITION SHALL BE DOCUMENTED BY THE CITY OF FORT COLLINS CONSTRUCTION INSPECTOR BEFORE ANY CUTS ARE MADE. PATCHING SHALL BE DONE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. THE FINISHED PATCH SHALL BLEND IN SMOOTHLY INTO THE EXISTING SURFACE. ALL LARGE PATCHES SHALL BE PAVED WITH AN ASPHALT LAY-DOWN MACHINE. IN STREETS WHERE MORE THAN ONE CUT IS MADE, AN OVERLAY OF THE ENTIRE STREET WIDTH, INCLUDING THE PATCHED AREA, MAY BE REQUIRED. THE DETERMINATION OF NEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE CITY OF FORT COLLINS TRAFFIC ENGINEER AND/OR THE CITY OF FORT COLLINS INSPECTOR AT THE TIME THE CUTS ARE MADE. 43. UPON COMPLETION OF CONSTRUCTION, THE SITE SHALL BE CLEANED AND RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED BEFORE CONSTRUCTION, OR TO THE GRADES AND CONDITION AS REQUIRED BY THESE PLANS. 44. STANDARD HANDICAP RAMPS ARE TO BE CONSTRUCTED AT ALL CURB RETURNS AND AT ALL "T" INTERSECTIONS. 45. AFTER ACCEPTANCE BY THE CITY OF FORT COLLINS, PUBLIC IMPROVEMENTS DEPICTED IN THESE PLANS SHALL BE GUARANTEED TO BE FREE FROM MATERIAL AND WORKMANSHIP DEFECTS FOR A MINIMUM PERIOD OF TWO YEARS FROM THE DATE OF ACCEPTANCE. 46. THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF ROADWAY AND APPURTENANT IMPROVEMENTS, INCLUDING STORM DRAINAGE STRUCTURES AND PIPES, FOR THE FOLLOWING PRIVATE STREETS: 47. APPROVED VARIANCES ARE LISTED AS FOLLOWS: NONE 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L UPPER RAIN GARDEN LOWER RAIN GARDEN SHELTER SPORT COURT DOG PARK TOT-LOT BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F UPPER RAIN GARDEN LOWER RAIN GARDEN FFE 5100.30 FFE 5094.20 FFE 5089.00 FFE 5084.35 FFE 5095.50 FFE 5092.50 FFE 5099.37 FFE 5099.52 FFE 5099.37 FFE 509 4 . 2 5 FFE 509 3 . 7 5 FFE 509 3 . 2 5 FFE 509 2 . 7 5 FFE 509 2 . 2 5 FFE 509 1 . 7 5 FFE5091.9 5 FFE5091.7 5 FFE5091.5 5 FFE5091.3 5 FFE5091.1 5 FFE5090.9 5 BUILDING A SF DIP DIP DIP SF SF SF SF DIP DIP DIP DIP DIP DIP VTC DIP DIP DIP DIP SFSF RD DIP DIP RD DIP VTC Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ E R O S I O N . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 6 A M PL O T D A T E : 04 ER O S I O N C O N T R O L P L A N MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 0 SCALE:1" = 30' 15'30'60'90' 294 LEGEND STANDARD EROSION AND SEDIMENT CONTROL CONSTRUCTION PLAN NOTES (1.) THE EROSION CONTROL INSPECTOR MUST BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO ANY CONSTRUCTION ON THIS SITE. (2.)THERE SHALL BE NO EARTH-DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. (3.)ALL REQUIRED PERIMETER SILT AND CONSTRUCTION FENCING SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITY (STOCKPILING, STRIPPING, GRADING, ETC). ALL OTHER REQUIRED EROSION CONTROL MEASURES SHALL BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT. (4.)AT ALL TIMES DURING CONSTRUCTION, THE DEVELOPER SHALL BE RESPONSIBLE FOR PREVENTING AND CONTROLLING ON-SITE EROSION INCLUDING KEEPING THE PROPERTY SUFFICIENTLY WATERED SO AS TO MINIMIZE WIND BLOWN SEDIMENT. THE DEVELOPER SHALL ALSO BE RESPONSIBLE FOR INSTALLING AND MAINTAINING ALL EROSION CONTROL FACILITIES SHOWN HEREIN. (5.)PRE-DISTURBANCE VEGETATION SHALL BE PROTECTED AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF EXISTING VEGETATION SHALL BE LIMITED TO THE AREA(S) REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATIONS, AND FOR THE SHORTEST PRACTICAL PERIOD OF TIME. (6.)ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.) SHALL BE KEPT IN A ROUGHENED CONDITION BY RIPPING OR DISKING ALONG LAND CONTOURS UNTIL MULCH, VEGETATION, OR OTHER PERMANENT EROSION CONTROL BMPS ARE INSTALLED. NO SOILS IN AREAS OUTSIDE PROJECT STREET RIGHTS-OF-WAY SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR MORE THAN THIRTY (30) DAYS BEFORE REQUIRED TEMPORARY OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED, UNLESS OTHERWISE APPROVED BY THE CITY/COUNTY. (7.)IN ORDER TO MINIMIZE EROSION POTENTIAL, ALL TEMPORARY (STRUCTURAL) EROSION CONTROL MEASURES SHALL: (A.)BE INSPECTED AT A MINIMUM OF ONCE EVERY TWO (2) WEEKS AND AFTER EACH SIGNIFICANT STORM EVENT AND REPAIRED OR RECONSTRUCTED AS NECESSARY IN ORDER TO ENSURE THE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. (B.)REMAIN IN PLACE UNTIL SUCH TIME AS ALL THE SURROUNDING DISTURBED AREAS ARE SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (C.)BE REMOVED AFTER THE SITE HAS BEEN SUFFICIENTLY STABILIZED AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (8.)WHEN TEMPORARY EROSION CONTROL MEASURES ARE REMOVED, THE DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEAN UP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM ALL DRAINAGE INFRASTRUCTURE AND OTHER PUBLIC FACILITIES. (9.)THE CONTRACTOR SHALL IMMEDIATELY CLEAN UP ANY CONSTRUCTION MATERIALS INADVERTENTLY DEPOSITED ON EXISTING STREETS, SIDEWALKS, OR OTHER PUBLIC RIGHTS OF WAY, AND MAKE SURE STREETS AND WALKWAYS ARE CLEANED AT THE END OF EACH WORKING DAY. (10.) ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY WATERS OF THE UNITED STATES. (11.) NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT BY SURFACE ROUGHENING, WATERING, AND PERIMETER SILT FENCING. ANY SOIL STOCKPILE REMAINING AFTER THIRTY (30) DAYS SHALL BE SEEDED AND MULCHED. (12.) THE STORMWATER VOLUME CAPACITY OF DETENTION PONDS WILL BE RESTORED AND STORM SEWER LINES WILL BE CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER TO THE CITY/COUNTY OR HOMEOWNERS ASSOCIATION (HOA). (13.) CITY ORDINANCE AND COLORADO DISCHARGE PERMIT SYSTEM (CDPS) REQUIREMENTS MAKE IT UNLAWFUL TO DISCHARGE OR ALLOW THE DISCHARGE OF ANY POLLUTANT OR CONTAMINATED WATER FROM CONSTRUCTION SITES. POLLUTANTS INCLUDE, BUT ARE NOT LIMITED TO DISCARDED BUILDING MATERIALS, CONCRETE TRUCK WASHOUT, CHEMICALS, OIL AND GAS PRODUCTS, LITTER, AND SANITARY WASTE. THE DEVELOPER SHALL AT ALL TIMES TAKE WHATEVER MEASURES ARE NECESSARY TO ASSURE THE PROPER CONTAINMENT AND DISPOSAL OF POLLUTANTS ON THE SITE IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS. (14.) A DESIGNATED AREA SHALL BE PROVIDED ON SITE FOR CONCRETE TRUCK CHUTE WASHOUT. THE AREA SHALL BE CONSTRUCTED SO AS TO CONTAIN WASHOUT MATERIAL AND LOCATED AT LEAST FIFTY (50) FEET AWAY FROM ANY WATERWAY DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION ACTIVITIES THE CONCRETE WASHOUT MATERIAL WILL BE REMOVED AND PROPERLY DISPOSED OF PRIOR TO THE AREA BEING RESTORED. (15.) TO ENSURE THAT SEDIMENT DOES NOT MOVE OFF OF INDIVIDUAL LOTS ONE OR MORE OF THE FOLLOWING SEDIMENT/EROSION CONTROL BMPS SHALL BE INSTALLED AND MAINTAINED UNTIL THE LOTS ARE SUFFICIENTLY STABILIZED, AS DETERMINED BY THE EROSION CONTROL INSPECTOR. (A.)ALONG LOT PERIMETER. (B.)OTHER LOCATIONS, IF NEEDED. (16.) CONDITIONS IN THE FIELD MAY WARRANT EROSION CONTROL MEASURES IN ADDITION TO WHAT IS SHOWN ON THESE PLANS. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AS DIRECTED BY THE CITY/COUNTY. SEPTEMBER 2003 (REVISED JULY 2010) NORTH 5095 5094 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 5095 5094 Best Management Practices (BMP's)Mobilization Foundation Excavation Site Grading Vertical Construction Flatwork Installaton Landscaping Demobilization STRUCTURAL "INSTALLATION" Silt Fence Vehicle Tracking Pad Inlet Protection (Any existing inlets downstream of site) Sediment Trap / Filter (in the rain garden forebays) Contour Furrows (Ripping / Disking) Flow Barriers / Wattle Dikes Riprap Armoring *All BMP's are to be removed once construction is complete VEGETATIVE Temporary Seeding / Planting Any time the site will sit dormant longer than 30 days. Mulching / Sealant Any time the site will sit dormant longer than 30 days. Sod Installation Permanent Seeding / Planting Rolled Products (Netting / Blankets / Mats)Any time the site will sit dormant longer than 30 days. 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L AV O N D A L E R O A D WO O D R O W DR I V E TR I A N G L E D R I V E EXISTING INLET CORE SOUTH WALL OF INLET BOX TO ACCEPT PIPING FROM PROPOSED DEVELOPMENT PIPE ELEVATION AT ENTRANCE TO STORM INLET APPROXIMATELY 5070.69' BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F 10' TYPE 'R' INLET INLET STRUCTURE MANHOLE LID-2 DAYLIGHT HDPE STORM DRAIN IN EROSION PROTECTED RUNDOWN TO RAIN GARDEN, (TYP) SEE AREA DRAINAGE PLAN. TEE INVERT ELEV. = 5081.15 8.6 LF 12" HDPE N-12 STORM DRAIN @ 2.33% APPROX. CENTERLINE OF DRAINAGE SWALE @ 2.0% +/- SLOPE (TYP) 43.7 LF 12" HDPE N-12 STORM DRAIN @ 1.20% 98.1 LF 12" HDPE N-12 STORM DRAIN @ 4.43% TEE INVERT EL. = 5086.05 INLET INV. EL. = 5091.2 NYLOPLAST AREA INLET W/ 12" SQ. STD. GRATE (TYP) SEE DETAIL SHT. 12 INLET INV. EL. = 5087.0 156.5 LF HDPE N-12 STORM DRAIN @ 3.13% 12.0 LF 12" HDPE N-12 STORM DRAIN @ 0.80% 31.4 LF 12" HDPE N-12 STORM DRAIN @ 1.59% 123.5 LF 12" HDPE N-12 STORM DRAIN @ 6.5% +/- 40.5 LF HDPE N-12 STORM DRAIN @ 0.5% +/- INLET INVERT ELEV. = 5092.0 EXISTING 24" RCP EXISTING 36" RCP FOREBAY OVERFLOW WEIR, 12" TALL, WITH 1" WIDE, FULL-DEPTH DRAINAGE SLOTS @ 1.5' +/- CENTERS. KEY WEIR INTO SIDE EMBANKMENTS. RAIN GARDEN CONCRETE FOREBAY WITH OVERFLOW WEIR, FOR DETAILS, SEE SHEET 13 FOREBAY OVERFLOW WEIR, 12" TALL, WITH 1" WIDE, FULL-DEPTH DRAINAGE SLOTS @ 1.5' +/- CENTERS. KEY WEIR INTO SIDE EMBANKMENTS. RAIN GARDEN CONCRETE FOREBAY WITH OVERFLOW WEIR, FOR DETAILS, SEE SHEET 13 LOWER RAIN GARDEN OUTLET CONTROL STRUCTURE. FOR DETAILS, SEE SHEET 13 INDICATED INVERT OF EXISTING INLET = 7070.69 TO BE CONFIRMED PRIOR TO COMMENCEMENT OF CONSTRUCTION. MANHOLE LID-1 INFLOW ENERGY DISSIPATION STRUCTURE - 1 LID SYSTEM PIPING (SEE PROFILE ON SEPARATE SHEET) BUILDING A 32.7 LF HDPE N-12 STORM DRAIN @ 1.2% ± TEE INV. EL. = 5086.40 106.1 LF 12" HDPE N-12 STORM DRAIN @ 4.7% +/- TEE INVERT ELEV. = 5081.00 24.6 LF HDPE N-12 STORM DRAIN @ 1.22% OUTLET CONTROL STRUCTURE - 1 107.0 LF 12" HDPE N-12 STORM DRAIN @ 1.9% +/- 4" DIA. SLOTTED PVC SUB-DRAIN PIPES FOR DETAILS, SEE SHEET 13 4" DIA. SLOTTED PVC SUB-DRAIN PIPES FOR DETAILS, SEE SHEET 13 10.6 LF 12" HDPE N-12 STORM DRAIN @ 1.00% EXISTING INLET CORE SOUTH WALL OF INLET BOX TO ACCEPT PIPING FROM PROPOSED DEVELOPMENT PIPE ELEVATION AT ENTRANCE TO STORM INLET APPROXIMATELY 5070.69' UPPER RAIN GARDEN LOWER RAIN GARDEN SHELTER SPORT COURT DOG PARK TOT-LOT FL O W T O E X . P O N D 1 EXISTING DETENTION POND 11b 1 2 5 15 6 12 1 2 4 5 6 9 11 0.493 0.48 0.789 0.71 1.313 0.64 0.193 0.37 0.064 0.50 0.116 0.44 0.640 0.04 11 14 8 0.170 0.42 10 0.190 0.11 13 4 10 8 9 7 3 1.081 0.09 3 FFE 5100.30 FFE 5092.50 FFE 5095.50 FFE 5094.20 FFE 5089.00 FFE 5084.35 7 0.144 0.44 NORTH 0 SCALE:1" = 30' 15'30'60'90' Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ D R A I N A G E . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 6 A M PL O T D A T E : 05 DR A I N A G E P L A N MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 295 NOTES 1.SEE SHEETS 13-14 FOR STORM DRAIN PLANS & PROFILES. LEGEND DRAINAGE BASIN I.D. DESIGN POINT OVERLAND FLOW DIRECTION # # 0.000.000 MINOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA (AC) DRAINAGE BASIN 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 Ridgewood Hills Fifth Filing DRAINAGE DATA SUMMARY TABLE Drainage Basin No.Design Point Basin Area (ac) Comp. Runoff Coeff.Design Runoff 2-Year 100-Year 2-Year 100-Year (cfs)(cfs) 1 1 0.493 0.48 0.73 0.62 3.18 2 2 0.789 0.71 0.85 1.49 5.87 3 3 1.081 0.09 0.53 0.22 9.30 4 4 1.313 0.64 0.81 2.08 8.77 5 6 0.193 0.37 0.67 0.21 1.28 6 7 0.064 0.50 0.73 0.09 0.47 7 8 0.144 0.44 0.70 0.18 1.00 8 9 0.170 0.42 0.69 0.20 1.17 9 10, 11, 12, 13 0.116 0.44 0.70 0.14 0.81 10 5, 14 0.190 0.11 0.54 0.06 1.01 11 15 0.640 0.04 0.50 0.06 2.61 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L AV O N D A L E R O A D WO O D R O W DR I V E TR I A N G L E D R I V E BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F BUILDING A DOG PARK SHELTER SPORTS COURT TOT-LOT 31.4 LF 12" HDPE N-12 STORM DRAIN @ 1.59% TEE INVERT ELEV. = 5081.15 TEE INVERT ELEV. = 5081.00 24.6 LF HDPE N-12 STORM DRAIN @ 1.22% 8.6 LF 12" HDPE N-12 STORM DRAIN @ 2.33% TEE INV. EL. = 5086.40 98.1 LF 12" HDPE N-12 STORM DRAIN @ 4.43% TEE INVERT EL. = 5086.05 AREA INLET GR. EL. = 5092.70 INV. EL. = 5091.20 AREA INLET GR. EL. = 5092.9 INV. EL. = 5091.9 AREA INLET GR. EL. = 5092.30 INV. EL. = 5091.30 98.4 LF 12" HDPE N-12 STORM DRAIN @ 4.98% AREA INLET GR. EL. = 5087.65 INV. EL. = 5086.15 10.6 LF 12" HDPE N-12 STORM DRAIN @ 1.00% AREA INLET GR. EL. = 5091.90 INV. EL. = 5090.40 AREA INLET GR. EL. = 5087.60 INV. EL. = 5086.60 AREA INLET GR. EL. = 5082.80 INV. EL. = 5081.30 AREA INLET GR. EL. = 5082.75 INV. EL. = 5081.25 AREA INLET GR. EL. = 5082.15 INV. EL. = 5080.65 AREA INLET GR. EL. = 5094.00 INV. EL. = 5092.50 AREA INLET GR. EL. = 5094.30 INV. EL. = 5092.20 AREA INLET GR. EL. = 5094.50 INV. EL. = 5091.84 34.1 LF 8" HDPE N-12 STORM DRAIN @ 1.00% 43.7 LF 12" HDPE N-12 STORM DRAIN @ 1.20% 12.0 LF 12" HDPE N-12 STORM DRAIN @ 0.80% 36.2 LF 10" HDPE N- 12 STORM DRAIN @ 1.00% AREA INLET GR. EL. = 5091.30 INV. EL. = 5089.80 53.82 LF 12" HSPE N-12 STORM DRAIN @ 4.03% TEE INV. EL. = 5089.67 13.15 LF 8" HDPE N-12 STORM DRAIN @ 1.00% 61.7 LF 12" HDPE N-12 STORM DRAIN @ 1.40% AREA INLET GR. EL. = 5091.50 INV. EL. = 5088.81 AREA INLET GR. EL. = 5091.50 INV. EL. = 5088.50 21.3 LF 12" HDPE N-12 STORM DRAIN @ 1.40% 35.6 LF 12" HDPE N-12 STORM DRAIN @ 1.43% 34.5 LF 12" HDPE N-12 STORM DRAIN @ 1.43% 12" HDPE BEND INV. EL. = 87.99 DAYLIGHT HDPE STORM DRAIN W/ F.E.S. AT UPPER END OF RIPRAP RUNDOWN INV.EL. = 5077.0 +/- DAYLIGHT HDPE STORM DRAIN W/ F.E.S. AT UPPER END OF RIPRAP RUNDOWN INV.EL. = 5077.0 +/- 100.6 LF 12" HDPE N-12 STORM DRAIN @ 3.63% NORTH 0 SCALE:1" = 30' 15'30'60'90' Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ D R A I N A G E . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 6 A M PL O T D A T E : 06 LA N D S C A P E D A R E A S D R A I N A G E S Y S T E M P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 296 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L LEGEND OVERLAND FLOW DIRECTION 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 AV O N D A L E R O A D WO O D R O W DR I V E TR I A N G L E D R I V E HP? BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F UPPER RAIN GARDEN LOWER RAIN GARDEN FFE 5100.30 FFE 5094.20 FFE 5089.00 FFE 5084.35 FFE 5095.50 FFE 5092.50 FFE 5099.37 FFE 5099.52 FFE 5099.37 FFE 509 4 . 2 5 FFE 509 3 . 7 5 FFE 509 3 . 2 5 FFE 509 2 . 7 5 FFE 509 2 . 2 5 FFE 509 1 . 7 5 FFE5091.9 5 FFE5091.7 5 FFE5091.5 5 FFE5091.3 5 FFE5091.1 5 FFE5090.9 5 SHELTER SPORT COURT DOG PARK TOT-LOT BUILDING A APPROXIMATE LOCATION OF EXISTING SPEED HUMP. REMOVE, TO FACILITATE CONSTRUCTION OF WATER AND SEWER TIE-INS, AND RECONSTRUCT AT NEW LOCATION 50' EAST. FOR SPEED HUMP DETAILS, SEE STD DETAIL 1802F ON SHT. 27. PROPOSED RELOCATION OF SPEED HUMP EXISTING SAN. MANHOLE 98.00 97.73 97.87 97.40 97.97 98.51 98.56 98.39 98.29 98.42 BVC 0+60.00 98.82 98.77 95.00 95.00 95.00 95.00 92.00 92.00 92.00 92.00 99.80 99.80 99.80 99.80 93.70 93.70 93.70 93.70 88.50 88.50 88.50 88.50 83.60 83.60 83.60 83.60 92.90 96.16 95.42 97.24 95.81 97.06 96.95 97.03 96.75 99.05 99.50 99.35 98.62 98.63 98.69 90.33 98.93 98.45 98.77 HP 0+91.45 99.13 INT 1+70.33 0+00.00 (SOUTH DRIVE) 97.19 98.86 98.45 EVC 1+60.00 97.64 82.63 82.55 97.73 90.29 90.13 89.65 BVC 3+48.10 89.89 PT 3+26.12 90.11 EVC 3+98.10 89.89 90.13 89.65 90.00 89.65 89.65 90.43 90.12 92.06 93.67 PC 2+68.00 90.69 94.93 90.31 85.85 86.32 85.30 85.81 84.83 83.20 83.35 86.84 87.09 86.52 81.21 83.45 83.94 93.77 93.80 93.36 83.92 84.0290.85 90.7789.57 84.68 89.67 88.82 89.81 PT 2+52.85 90.84 EVC 2+38.11 90.99 91.57 91.32 91.12 92.28 92.49 92.88 94.60 93.51 94.84 86.13 93.43 93.91 94.17 93.03 BVC 1+38.11 93.6293.84 93.80 86.36 94.35 89.86 89.73 89.97 90.86 94.12 98.52 94.00 93.58 92.00 91.9391.81 91.62 99.24 99.01 99.00 95.17 EVC 0+62.0 96.86 97.11 97.19 97.67 97.53 BVC 0+38.11 97.4398.20 98.42 97.90 97.32 98.45 97.83 97.40 95.49 95.54 PT 3+15.10 90.87 90.40 90.61 90.38 89.61 87.02 BVC 4+48.00 85.08 EVC 5+48.00 81.40 80.97 80.73 81.79 81.06 81.00 81.16 85.98 84.77 85.36 B.P. 97.96 92.27 85.08 85.69 84.61 84.44 84.40 84.58 84.67 84.89 84.39 85.87 86.26 86.85 86.46 84.76 84.97 78.60 93.60 93.05 93.70 93.71 LP 93.57 91.90 95.33 91.35 91.79 91.79 91.3591.50 91.45 RETAINING WALL (18" MAX. HT.) 97.01 97.78 97.85 98.00 92.39 91.75 EVC 90.85 90.92 RETAINING WALL RETAINING WALL 85.00 85.00 84.00 84.00 BVC 91.86 (3) STEPS (4) STEPS (3) STEPS (2) STEPS Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ G R A D I N G . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 6 A M PL O T D A T E : 07 GR A D I N G P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 297 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH 0 SCALE:1" = 30' 15'30'60'90' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 GRADING NOTES 1. ALL EASEMENTS ARE PROPOSED AND WILL BE DEDICATED BY THE PLAT. EASEMENTS ARE LABELED ON THE UTILITY PLAN. 2. THE DRIVES WITHIN THE SITE WILL BE PRIVATELY OWNED AND MAINTAINED. THERE WILL BE NO PUBLIC MAINTENANCE OF THE DRIVES. 3.LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS SHALL BE IN ACCORDANCE WITH THE CITY STREET REPAIR STANDARDS. 4.NO OFF SITE GRADING IS PROPOSED WITH THIS DEVELOPMENT. 5.SEE LANDSCAPE PLAN FOR REVEGETATION METHODS AND DETAILS. 6.ALL SPOT ELEVATIONS SHOWN ARE FLOWLINE UNLESS NOTED OTHERWISE. 7.ALL RETAINING WALLS FOUR (4) FEET OR HIGHER WILL REQUIRE A BUILDING PERMIT. LEGEND 5095 5094 5095 5094 BUILDING C BUILDING D BUILDING E BUILDING F UPPER RAIN GARDEN LOWER RAIN GARDEN FFE 5100.30 FFE 5094.20 FFE 5089.00 FFE 5084.35 FFE 5095.50 FFE 5092.50 FFE 5099.37 FFE 5099.52 FFE 5099.37 FFE 509 4 . 2 5 FFE 509 3 . 7 5 FFE 509 3 . 2 5 FFE 509 2 . 7 5 FFE 509 2 . 2 5 FFE 509 1 . 7 5 FFE5091.9 5 FFE5091.7 5 FFE5091.5 5 FFE5091.3 5 FFE5091.1 5 FFE5090.9 5 SHELTER SPORT COURT DOG PARK TOT-LOT BUILDING A WO O D R O W DR I V E TR I A N G L E D R I V E 9' E X I S T I N G U&D E 9' EX I S T I N G U&DE 6' EX I S T I N G U& D E 76' R O W 30 ' U,D , A , E A E 30'U,D, A , E A E 30 ' U, D , A , E A E 6' E X I S T I N G U& D E 30 ' D E 30' U,D , A , E A E EXI S T I N G 5 7 ' R O W 30' U,D,A , E A E 9' U&D E 5'3' A C C E S S EAS E M E N T R51' AE 30 ' U,D , A , E A E 30 ' D E 50 ' D E EX SANITARY MH RIM=5101.43 INV NW=5090.24 INV NE=5090.20 EX SANITARY MH RIM=5075.75 INV E=5067.17 INV SW=5072.65 INV SW=5067.52 EXISTING INLET AND STORM DRAINS EX SANITARY MH RIM=5101.46 INV NE=5091.40 INV SW=5091.53 CUT INTO EXISTING WATER MAIN NEW 8" X 8" TEE W/ T.B. AND TWO (2) 8" GATE VALVES 8" X 6" TEE W/ TB 6" GV & 8" GV 81.21 LF 8" PVC SEWERLINE 72.59 LF 8" PVC WATERLINE SMH-3 22.8 LF 12" HDPE STORM DRAIN 43.5 LF 12" HDPE STORM DRAIN 109.7 LF 15" HDPE STORM DRAIN 330 LF 4" PERFORATED PIPE, SEE LID PLANS SAWCUT AND REPLACE EXISTING PAVEMENT IN THIS AREA 27.95 LF 24" HDPE STORM DRAIN 217.8 LF 4" SLOTTED PVC PIPE, SEE LID PLANS 8" X 6" TEE W/ TB 6" GV 90 DEG. BEND W/ TB AND 8" GV SMH-2 EX SANITARY MH RIM=5087.07 INV NW=5076.63 INV NE=5076.50 INV SW=5076.60 4" FIRE LINE 1-1/2" WATER SERVICE IRRIGATION CONTROLLER 1.5" WATER IRRIGATION SERVICE W/ METER 4" FIRE LINE 1-1/2" WATER SERVICE 4" SEWER SERVICE 4" SEWER SERVICE 4" FIRE LINE 1-1/2" WATER SERVICE 4" SEWER SERVICE HYDRANT ASSEMBLY 4" SEWER SERVICE EX SANITARY MH RIM=5081.77 INV NE=5074.65 INV SW=5074.84 149.34 LF 8" PVC WATERLINE 4" FIRE LINE 3/4" WATER SERVICE 1-1/2" WATER SERVICE 79 LF 12" HDPE STORM DRAIN 168.14 LF 8" PVC SEWERLINE 8" X 4" TEE W/ TB 4" GV 8" X 4" TEE W/ TB 4" GV 8" X 4" TEE W/ TB 4" GV 8" X 4" TEE W/ TB 4" GV EXISTING 1-1/2" WATER SERVICE 10' TYPE 'R' INLET MANHOLE LID-1 12" HDPE FES OUTLET CONTROL STRUCTURE - 1 10' TYPE "R" INLET MANHOLE LID-2 OUTLET CONTROL STRUCTURE - 2 111.8 LF 12" HDPE STORM DRAIN63.3 LF 12" HDPE STORM DRAIN 161.2 LF 15" HDPE STORM DRAIN 98.2 LF 12" HDPE STORM DRAIN 156.52 LF 12" HDPE STORM DRAIN 10.6 LF 12" HDPE STORM DRAIN 31.4 LF 12" HDPE STORM DRAIN 12.0 LF 12" HDPE STORM DRAIN 96.5 LF 12" HDPE STORM DRAIN 24.5 LF 12" HDPE STORM DRAIN 106.0 LF 12" HDPE STORM DRAIN 1.7 LF 12" HDPE STORM DRAIN 8.4 LF 12" HDPE STORM DRAIN95.8 LF 12" HDPE STORM DRAIN 32.7 LF 12" HDPE STORM DRAIN 1.2 LF 12" HDPE STORM DRAIN 40.5 LF 12" HDPE STORM DRAIN EXISTING RELOCATED FIRE HYDRANT 376.62 LF 8" PVC WATERLINE 215.28 LF 8" PVC SEWERLINE SMH-4 EXISTING 8 X 8 TEE EXISTING 8" WATER LINE EXISTING 4" FIRE LINE EXISTING 1-1/2" WATER SERVICE EXISTING 4" FIRE LINE EXISTING 4" SEWER SERVICE EXISTING 4" SEWER SERVICE 4" SEWER SERVICE 4" SEWER SERVICE 10 LF 4" SOLID PVC PIPE 16.5 LF 12" HDPE STORM DRAIN MANHOLE LID-3 12" HDPE FES REMOVE EXISTING TEMPORARY HYDRANT, EXTEND HYDRANT LEAD 15.0', AND REINSTALL HYDRANT, WITH PUMPER PORT FACING DRIVE AISLE EXISTING STREET LIGHT SIDEWALK CHASE, (TYP)METER BANK (TYP) TRANSFORMER (TYP) EXISTING SPEED HUMP TO BE REMOVED AND RELOCATED BUILDING B RETAINING WALL RETAINING WALL (3) STEPS (4) STEPS (3) STEPS (2) STEPS RETAINING WALL AV O N D A L E R O A D NEW MANHOLE CONSTRUCTED OVER EXISTING SANITARY MAIN Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ O V E R A L L - U T I L I T Y . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 7 A M PL O T D A T E : 08 OV E R A L L U T I L I T Y P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 298 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L LEGEND PROPOSED STORM DRAIN WITH MANHOLE PROPOSED STORM INLET PROPOSED SANITARY SEWER WITH MANHOLE PROPOSED WATERLINE WITH VALVE & FIRE HYDRANT PROPOSED WATERLINE TAP METER PROPOSED FIRELINE TAP PROPOSED PRIMARY ELECTRIC LINE PROPOSED SECONDARY ELECTRIC LINE PROPOSED IRRIGATION LINE WITH METER EXISTING SANITARY SEWER EXISTING WATERLINE EXISTING STORM DRAIN PIPE EXISTING STREET LIGHT EXISTING FIRE HYDRANT EXISTING ELECTRIC LINE EXISTING GAS LINE UTILITY NOTES 1.ALL SANITARY SEWER PIPE IS 8" PVC SDR-35, UNLESS NOTED OTHERWISE.. 2.ALL SANITARY SEWER, WATER AND STORMWATER CONSTRUCTION SHALL CONFORM TO SOUTH FORT COLLINS SANITATION DISTRICT, FORT COLLINS-LOVELAND WATER DISTRICT, AND CITY OF FORT COLLINS STORMWATER DEVELOPMENT, RESPECTIVELY CONSTRUCTION STANDARDS AND DETAILS. 3.ALL REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III OR BETTER UNLESS NOTED OTHERWISE. 4.ALL WATERLINE TO BE CONSTRUCTED A MINIMUM OF 5' AND A MAXIMUM OF 6' (5' TYPICAL) BELOW FINISHED GRADE UNLESS OTHERWISE NOTED. 5.ALL WATERLINE SERVICES TO BE SIZED AS SHOWN ON THE UTILITY PLANS. 6.PROVIDE 10' HORIZONTAL CLEARANCE BETWEEN WATER AND SEWER PIPES. 7.SEE UTILITY PLANS FOR EASEMENT DELINEATION, DIMENSIONS AND DETAILS. 8.SEE UTILITY DETAIL SHEETS FOR SERVICE CONNECTION DETAILS. 9.REDUCED PRESSURE PRINCIPLE (RP) BACK-FLOW-PREVENTION-DEVICES TO BE INSTALLED ON THE FIRE LINE RISERS AND DOMESTIC WATER SERVICES. 10.TELEPHONE AND CATV TO BE INSTALLED IN COMMON TRENCH WITH POWER. NORTH 0 SCALE:1" = 30' 15'30'60'90' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F UPPER RAIN GARDEN LOWER RAIN GARDEN AV O N D A L E R O A D SHELTER SPORT COURT DOG PARK TOT-LOT BUILDING A WO O D R O W DR I V E TR I A N G L E D R I V E 24' 76' R O W 24 ' 24' N: 1419764.910 E: 3116746.426 N: 1419821.871 E: 3116641.824 N: 1419925.535 E: 3116734.930 N: 1420022.597 E: 3116820.262 N: 1420133.420 E: 3116843.218 24' 8' 8' 8' 9' 5' 11' 20 ' 20 ' N: 1419621.050 E: 3116944.340 N: 1419692.656 E: 3116863.577 N: 1419674.038 E: 3116804.669 N: 1419934.833 E: 3116648.760 N: 1420038.497 E: 3116741.866 N: 1420126.008 E: 3116919.543 N: 1420209.396 E: 3116988.073 EXISTING STREET LIGHT 5' 5' 5' 5' PROPOSED LOCATION FOR SPEED HUMP RELOCATION 17' 17' 5' 11' TYP. STD. PARKING STALL TYP. VAN ACCESSIBLE PARKING STALL TYP. H.C. PARKING STALL EXISTING H.C. RAMP 20' ROLL-OVER CURB SECTION SIDEWALK CHASE WITH SIDEWALK WIDENING PER CITY STANDARD DETAIL. (TYP) Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ H O R I Z O N T A L . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 7 A M PL O T D A T E : 09 HO R I Z O N T A L C O N T R O L P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 299 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH 0 SCALE:1" = 30' 15'30'60'90' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 APPROXIMATE LIMITS OF PAVEMENT REMOVAL FOR TIE-IN OF WATER AND SEWER MAINS SHOWN HATCHED. APPROXIMATE LOCATION OF EXISTING SPEED HUMP. REMOVE TO FACILITATE TIE-IN OF WATER AND SEWER MAINS, AND RELOCATE 50' NORTH. REMOVE 30' OF EXISTING CURB & GUTTER AND REPLACE WITH 20' ROLL-OVER CURB & GUTTER, WITH 5' TRANSITION SECTIONS ON EACH END. INSTALL 20' WIDE X 6" THICK CONCRETE PAD FOR EMERGENCY ACCESS. LINE TABLE LINE ID L100 L101 L102 L103 L104 L105 L106 L107 LENGTH 132.33' 144.76' 62.00' 12.00' 125.50' 95.33' 15.15' 49.97' DIRECTION N41° 56' 11"E N41° 56' 11"E S33° 38' 17"E N33° 38' 17"W N33° 38' 17"W N15° 09' 14"E N74° 50' 46"W N48° 03' 49"W LINE TABLE LINE ID L142 L143 LENGTH 35.83' 15.13' DIRECTION N15° 09' 14"E N07° 33' 33"E LINE TABLE LINE ID L108 L109 L110 L111 L112 L113 L114 L115 L116 L117 L118 L119 L120 L121 L122 L123 L124 L125 L126 L127 LENGTH 14.94' 15.20' 12.00' 115.00' 12.00' 9.43' 12.00' 107.46' 12.02' 12.02' 12.02' 11.94' 12.11' 12.00' 12.00' 23.74' 12.00' 12.00' 23.75' 2.08' DIRECTION N49° 31' 40"E N41° 58' 05"E N48° 03' 49"W N41° 55' 56"E S48° 03' 49"E N41° 56' 11"E N48° 03' 49"W N41° 56' 11"E S47° 08' 49"E N45° 22' 52"W S35° 11' 27"E N33° 02' 49"W S25° 15' 36"E S24° 46' 46"E S24° 46' 46"E S33° 38' 41"E S56° 21' 19"W S56° 21' 19"W N33° 38' 41"W S52° 22' 45"W LINE TABLE LINE ID L128 L129 L130 L131 L132 L133 L134 L135 L136 L137 L138 L139 L140 L141 L144 L145 L146 L147 L148 L149 LENGTH 11.36' 11.98' 1.00' 67.67' 10.00' 22.08' 12.97' 11.97' 11.97' 0.70' 67.67' 0.71' 13.07' 44.50' 15.13' 80.33' 11.99' 10.78' 12.03' 12.03' DIRECTION S38° 13' 49"E N44° 44' 03"W S48° 03' 49"E S41° 56' 11"W S41° 56' 11"W S41° 56' 11"W S48° 03' 49"E N41° 13' 28"E S27° 38' 35"W N20° 03' 41"E S69° 56' 19"E S20° 03' 41"W S74° 50' 46"E S15° 09' 14"W N22° 44' 55"E N15° 09' 14"E S15° 09' 14"W N74° 50' 46"W N25° 19' 50"E S27° 38' 35"W LINE TABLE LINE ID L150 L151 L152 L153 L154 L155 L156 LENGTH 2.32' 0.27' 11.86' 5.36' 0.99' 70.67' 15.14' DIRECTION N48° 03' 49"W N41° 56' 11"E N40° 29' 15"E N48° 03' 49"W S48° 03' 49"E S41° 56' 11"W S34° 20' 42"W CURVE TABLE CURVE ID C100 C101 C102 C103 C104 ARC LENGTH 139.76' 7.28' 100.30' 58.12' 202.87' RADIUS 584.00' 584.00' 584.00' 37.00' 434.00' DELTA ANGLE 013°42'41" 000°42'50" 009°50'24" 090°00'00" 026°46'57" CHORD BEARING N48°47'32"E N56°00'18"E N61°16'55"E N29°50'46"W N61°27'17"W CHORD LENGTH 139.42' 7.28' 100.17' 52.33' 201.03' CURVE TABLE CURVE ID C105 C106 C107 C108 C109 C110 C111 C112 C113 C114 C115 C116 C117 C118 C119 C120 C121 C122 C123 C124 C125 C126 C127 ARC LENGTH 7.85' 7.85' 7.85' 9.81' 7.81' 8.45' 7.81' 109.02' 7.81' 11.19' 11.11' 7.90' 83.31' 7.73' 0.12' 59.72' 40.96' 40.97' 8.53' 63.00' 7.90' 27.20' 6.29' RADIUS 5.00' 5.00' 5.00' 613.00' 5.00' 596.00' 5.00' 613.00' 5.00' 596.00' 596.00' 5.00' 613.00' 5.00' 595.98' 572.00' 25.00' 24.98' 5.04' 555.00' 5.00' 572.00' 4.00' DELTA ANGLE 090°00'00" 090°00'00" 090°00'00" 000°55'00" 089°31'24" 000°48'45" 089°31'24" 010°11'25" 089°31'24" 001°04'34" 001°04'04" 090°28'36" 007°47'13" 088°34'11" 000°00'43" 005°58'56" 093°53'05" 093°59'41" 096°51'11" 006°30'14" 090°30'19" 002°43'29" 090°05'58" CHORD BEARING N3°03'49"W N86°56'11"E N3°03'49"W N42°23'41"E N88°05'28"E N43°44'10"E N0°37'10"W N49°42'50"E S79°57'09"E N55°49'26"E N56°53'45"E N12°11'29"E N61°46'53"E S69°32'42"E N66°10'34"E S63°13'53"W S13°17'52"W N80°34'51"W S3°42'54"W S48°31'04"W N89°59'12"W S43°23'54"W S3°00'50"E CHORD LENGTH 7.07' 7.07' 7.07' 9.81' 7.04' 8.45' 7.04' 108.88' 7.04' 11.19' 11.11' 7.10' 83.25' 6.98' 0.12' 59.69' 36.53' 36.53' 7.55' 62.97' 7.10' 27.20' 5.66' CURVE TABLE CURVE ID C128 C129 C130 C131 C132 C133 C134 C135 C136 C137 C138 C139 C140 C141 C142 C143 C144 C145 C146 C147 C148 C149 C150 ARC LENGTH 7.85' 39.27' 0.18' 7.91' 96.00' 7.91' 12.53' 6.65' 6.63' 76.97' 9.81' 98.13' 38.48' 8.01' 82.24' 7.80' 8.11' 7.80' 115.50' 7.73' 40.06' 6.16' 7.85' RADIUS 5.00' 25.00' 422.00' 5.00' 405.00' 5.00' 422.00' 4.00' 4.00' 49.00' 5.00' 50.00' 25.00' 5.00' 463.00' 5.00' 446.00' 5.00' 463.00' 5.00' 25.00' 4.00' 5.00' DELTA ANGLE 090°00'00" 090°00'00" 000°01'30" 090°41'13" 013°34'52" 090°41'13" 001°42'07" 095°11'35" 094°54'26" 090°00'00" 112°26'47" 112°26'47" 088°11'31" 091°48'29" 010°10'36" 089°21'53" 001°02'32" 089°21'53" 014°17'36" 088°33'04" 091°49'09" 088°10'51" 090°00'00" CHORD BEARING S86°56'11"W S3°03'49"E S48°04'34"E N86°34'04"E S55°33'59"E S17°42'01"E S63°53'41"E N67°39'28"E S27°23'33"E S29°50'46"E S41°04'09"E S41°04'09"E N28°56'31"W S61°03'29"W N69°45'28"W N19°21'07"W N63°30'47"W S72°19'32"W N55°12'37"W N3°47'17"W S86°01'37"W S3°58'23"E S86°56'11"W CHORD LENGTH 7.07' 35.36' 0.18' 7.11' 95.78' 7.11' 12.53' 5.91' 5.89' 69.30' 8.31' 83.12' 34.79' 7.18' 82.13' 7.03' 8.11' 7.03' 115.20' 6.98' 35.91' 5.57' 7.07' Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ H O R I Z O N T A L . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 7 A M PL O T D A T E : 10 LI N E & C U R V E T A B L E S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2910 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 A V O N D A L E R O A D TRIANGLE DRIVE 509 9 51 0 0 50 9 8 50 9 7 50 9 6 50 9 5 50 9 4 50 9 3 50 9 2 50 9 1 50 9 0 50 8 9 50 8 8 50 8 7 50 8 6 50 8 5 50 8 4 50 8 3 50 8 5 50 8 550 8 6 50 8 7 50 8 4 5083 5087 5086 508 5 508 4 EXISTING 8" PVC WATER MAIN EXISTING 8" PVC WATER MAIN STUB REMOVE EXISTING TEMPORARY HYDRANT AND EXTEND WATER MAIN PER PLAN & PROFILE SALVAGE AND REINSTALL HYDRANT AT STA. 0+59.20 8" x 6" TEE (W) FOR HYDRANT ASSEMBLY STA. 0+59.20, O/S 5' L 1.5" WATER SERVICE (W) STA. 1+13.55, O/S 5' L 8" x 4" FIRE LINE TEE & G.V.(W) STA. 1+ 27.85, O/S 5' L 0.75" WATER SERVICE (E) STA. 2+36.07, O/S 5' L 1.5" WATER SERVICE (W) STA. 2+52.89, O/S 5' L 8" x 4" FIRE LINE TEE & G.V. (W) STA. 2+67.19, O/S 5' L 11.25 DEG. BEND STA. 3+86.60, O/S 9.49' L 1.5" WATER SERVICE (W) STA. 3+79.98, O/S 8.62' L 8' x 4" FIRE LINE TEE & G.V. (W) STA. 3+89.90, O/S 9.08' L 90 DEG. BEND STA. 4+57.27, O/S 5' L 8" X 6" SWIVEL TEE (S) FOR HYDRANT ASSEMBLY STA. 1+17.55, O/S 5.0' L 1.5" WATER SERVICE (N) STA. 1+53.11, O/S 5.0' L 8" X 4" FIRE LINE TEE & G.V. (N) STA. 2+14.27, O/S 5.0' L BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F SHELTER TOT-LOT SPORT COURT CUT EXISTING WATER MAIN AND INSTALL NEW 8" X 8" TEE W/ T.B. AND TWO 8" GATE VALVES. CONTRACTOR TO EXPOSE EXISTING WATER MAIN AND CONFIRM ELEVATION PRIOR TO COMMENCING CONSTRUCTION. NEW WATER MAIN IS TO BE INSTALLED EASTWARD FROM EXISTING WATER MAIN. 50995099 509 9 509 9 51 0 2 510 1 510 0 50 9 9 50 9 8 50 9 7 50 9 6 50 9 5 50 9 4 50 9 3 50 8 6 50 8 5 50 8 4 50 8 3 50 8 2 50 8 1 5097 50 8 6 508 3 5095 5096 509 8 5065 5070 5075 5080 5085 5090 5095 5065 5070 5080 5090 0+00 1+00 2+00 3+00 4+00 0+00 1+00 2+00 3+00 4+00 1. 5 ' M I N . CL E A R 8" X 6 " S W I V E L T E E ( S ) FO R H Y D R A N T A S S E M B L Y ST A . 1 + 1 7 . 5 5 1. 5 " W A T E R S E R V I C E T A P ( N ) ST A . 1 + 5 3 . 1 1 8" X 4 " F I R E L I N E T E E & G . V . (N ) S T A . 2 + 1 4 . 2 7 FFE OF ADJACENT BUILDING NORTH 4" SAN SEWER LATERAL CROSSING STA.1+81.31 MIN. INV. EL. AT CROSSING = 5080.84 MAX. INV. EL. AT CROSSING = 5084.91 EXISTING 8" PVC WATER MAIN 5070 5075 5080 5085 5090 5095 5100 5105 5110 5115 5070 5080 5090 5100 5110 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 1. 5 ' M I N . CL E A R 1. 5 ' M I N . CL E A R 8" x 6 " S W I V E L T E E ( W ) FO R H Y D R A N T A S S E M B L Y ST A . 0 + 5 9 . 2 0 1. 5 " W A T E R S E R V I C E T A P ( W ) ST A . 1 + 1 3 . 5 5 8" x 4 " F I R E L I N E T E E W / G . V . ( W ) ST A . 1 + 2 7 . 8 5 8" 9 0 D E G . B E N D ST A . 5 + 5 7 . 2 7 1. 5 " W A T E R S E R V I C E T A P ( W ) ST A . 2 + 5 2 . 8 9 8" x 4 " F I R E L I N E T E E & G . V . (W ) S T A . 2 + 6 7 . 1 9 1. 5 " W A T E R S E R V I C E T A P ( W ) ST A . 3 + 7 9 . 9 8 8" x 4 " F I R E L I N E T E E & G . V . ( W ) ST A . 3 + 8 9 . 9 0 8" 1 1 . 2 5 D E G . B E N D ST A . 3 + 8 6 . 6 0 0. 7 5 " W A T E R S E R V I C E T A P ( E ) 2+ 3 6 . 0 7 , ST A = 5 + 6 2 . 4 3 1.99% -4.36 % ST A = 0 + 3 3 . 0 0 EL E V = 5 0 9 8 . 2 9 EL E V = 5 0 8 0 . 9 7 -3.00% 4" SAN. SEWER LATERAL CROSSING. STA.1+75.00 MIN.INV. EL. AT CROSSING POINT = 5093.45 MAX.INV. EL. AT CROSSING POINT = 5095.28 EXISTING 8" PVC WATER MAIN IN AVONDALE RD. STA. 0+00.00 EXISTING 8" PVC WATER MAIN STUB, APPROX. 30 L.F. 4" SAN. SEWER LATERAL CROSSING STA. 3+14.40 MIN. INV. EL. AT CROSSING = 5087.31 MAX. INV. EL. AT CROSSING = 5089.18 DRIVE AISLE CENTERLINE PROFILE EXISTING GROUND PROFILE ALONG DRIVE AISLE CENTERLINE Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ W A T E R - P P . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 7 A M PL O T D A T E : 11 WA T E R P L A N & P R O F I L E 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2911 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 0 SCALE:1"=40' 20'40'80'120' NORTH WEST ACCESS DRIVE - WATER PROFILE WEST ACCESS DRIVE & EMERGENCY ACCESS - WATER PLAN HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' EMERGENCY ACCESS - WATER PROFILE HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 509 9 50 9 8 50 9 7 50 9 6 50 9 5 50 9 4 50 9 3 50 9 2 50 9 1 50 9 0 50 8 9 50 8 8 50 8 7 50 8 6 50 8 5 50 8 4 50 8 3 50 8 2 50 8 7 50 8 6 50 8 4 5083 50 8 4 50 8 7 5086 5085 5084 508 3 50 8 8 SMH N-4 STA. 1+70.33, O/S 5' R 4" SAN SERVICE (W) STA. 1+77.00 4" SAN SEWER SERVICE (W) STA. 3+16.40 4" SAN SEWER SERVICE (E) STA. 3+24.50 SMH N-2 STA. 4+67.21, O/S 5' R SMH N-3 STA. 3+85.63, O/S 0.59' R SAN. C.O. INV. = 5096.80 SAN. C.O. INV. = 5090.70 SAN. C.O. INV. = 5091.76 SAN. C.O. INV. = 5092.60 SMH N-1 STA. 2+67.02, O/S 5' R 4" SAN SEWER SERVICE STA. 1+91.21, O/S 5.0' R 4" SAN SEWER SERVICE STA. 1+83.31, O/S 5.0' R SAN.C.O. INV. = 5085.50 SAN.C.O. INV. = 5080.60 BUILDING E FFE = 5089.00 BUILDING F FFE = 5084.35 BUILDING DBUILDING C BUILDING B TOT-LOT SHELTER SPORTS COURT 509 5 5096 5097 509 8 509 9 510 0 510 2 5101 510 0 509 9 50 9 8 50 9 7 50 9 6 50 9 5 50 9 4 50 9 3 50 9 2 509 1 50 9 0 508 9 50 8 8 508 7 508 6 508 5 5083 5082 0+00 1+00 2+00 3+00 4+00 5+00 5+99 0+ 0 0 1+ 0 0 2+ 0 0 3+ 0 0 5070 5075 5080 5085 5090 5095 5100 5105 5110 5115 5070 5080 5090 5100 5110 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 SM H N - 2 ST A . 4 + 6 7 . 2 1 , O / S 5 ' R RI M = 5 0 8 4 . 3 7 IN V . I N ( S ) = 5 0 7 7 . 1 4 IN V . O U T ( W ) = 5 0 7 6 . 9 4 SM H N - 3 ST A . 3 + 8 5 . 6 3 , O / S 0 . 5 9 R RI M = 5 0 8 7 . 7 6 IN V . I N ( S ) = 5 0 8 0 . 6 9 IN V . O U T ( N ) = 5 0 8 0 . 4 9 SM H N - 4 ST A . 1 + 7 0 . 3 3 RI M = 5 0 9 7 . 2 9 . IN V . O U T ( N ) = 5 0 8 9 . 8 3 6" S A N . S E R V I C E ( W ) ST A . 1 + 7 7 . 0 0 6" S A N . S E R V I C E ( W ) ST A . 3 + 1 6 . 4 0 ST A = 5 + 6 2 . 4 3 1.99% -4.36 % ST A = 0 + 3 3 . 0 0 EL E V = 5 0 9 8 . 2 9 EL E V = 5 0 8 0 . 9 7 -3.00% DRIVE AISLE CENTERLINE PROFILE EXISTING GROUND PROFILE ALONG DRIVE AISLE CENTERLINE 0.75" WATER SERVICE (E) STA. 2+36.07, EL. 5058.9 ± 215.3 LF 8" PVC SDR 35 SAN. SEWER MAIN @ 4.33% 81.58 LF 8" PVC SDR 35 SAN. SEWER MAIN @ 4.32% 5065 5070 5075 5080 5085 5090 5095 5065 5070 5080 5090 0+00 1+00 2+00 3+00 4+00 0+00 1+00 2+00 3+00 4+00 SM H N - 2 ST A . 0 + 9 5 . 0 0 , O / S 5 . 0 0 ' R RI M = 5 0 8 4 . 3 7 IN V . I N ( S ) = 5 0 7 7 . 1 4 IN V . O U T ( W ) = 5 0 7 6 . 9 4 SM H N - 1 ST A . 2 + 6 7 . 0 2 , O / S 5 . 0 ' R RI M = 5 0 8 4 . 3 8 IN V . I N ( E ) = 5 0 7 5 . 8 3 IN V . O U T ( N ) = 5 0 7 5 . 6 3 4" S A N S E R V I C E ( N ) ST A . 1 + 9 1 . 2 1 6" S A N S E R V I C E ( S ) ST A . 1 + 8 3 . 3 1 172.00 L.F. 8" PVC SAN SEWER @ 0.66% Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ S E W E R - P P . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 8 A M PL O T D A T E : 12 SE W E R P L A N & P R O F I L E 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2912 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH 0 SCALE:1"=40' 20'40'80'120' WEST ACCESS DRIVE - SANITARY SEWER PROFILE WEST ACCESS DRIVE & EMERGENCY ACCESS - SANITARY SEWER PLAN HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' EMERGENCY ACCESS - SANITARY SEWER PROFILE HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 TRIANGLE DRIVE A V O N D A L E R O A D BUILDING F 5079 507 8 5081 5080 5079 5078 5077 5076 5075 5075 5076 5077 50 7 5 50 7 6 50 7 7 50 7 8 LOWER RAIN GARDEN MANHOLE LID-3 STA: 0+36.49 FOREBAY UNDERDRAIN PIPINGUNDERDRAIN CLEANOUT, (TYP) LOWER RAIN GARDEN OUTLET CONTROL STRUCTURE STA: 1+37.52 EXISTING INLET IN TRIANGLE DR. STA: 1+73.52 5060 5065 5070 5075 5080 5085 5090 5095 5100 5060 5070 5080 5090 5100 0+00 1+00 2+00 0+00 1+00 2+00 10 ' T Y P E " R " I N L E T ST A : 0 + 2 0 . 0 0 IN V . O U T : 5 0 7 6 . 7 0 MA N H O L E L I D - 3 ST A : 0 + 3 6 . 4 9 IN V . I N : 5 0 7 6 . 2 8 IN V . O U T : 5 0 7 5 . 9 9 12 " D I A . H D P E F E S ST A : 0 + 5 9 . 2 8 IN V . : 5 0 7 5 . 0 0 OU T L E T C O N T R O L S T R U C T U R E ST A : 1 + 3 7 . 5 2 OV E R F L O W W E I R E L E V : 5 0 7 5 . 7 5 IN V . E L E V : 5 0 7 2 . 5 0 SE E T Y P I C A L D E T A I L , T H I S S H E E T EX I S T I N G 2 0 ' T Y P E " R " I N L E T ST A : 1 + 6 2 . 6 2 IN V . I N : 5 0 7 0 . 6 9 16.49 LF 12" HDPE N-12 STORM PIPE @ 5.00% 15" DIA. HDPE STORM PIPE STA.: 0+45.00 T.O.P. ELEV.: 5073.55 22.79 LF 12" HDPE N-12 STORM PIPE @ 5.00% 2. 0 ' CL R 4" DIAPHRAGM AGGREGATE LAYER 4" DIA. SLOTTED / PERFORATED PVC UNDERDRAIN PIPE FOR SPECIFICATION, SEE SHT. 28 8" RESERVOIR AGGREGATE LAYER LOWER RAIN GARDEN PONDING DEPTH = 9" 18" BIORETENTION SAND MEDIA LAYER SEE DETAIL, SHT. 28 FLOOR OF RAIN GARDEN ELEV.: 5075.0 SUB-DRAIN CLEANOUT ONE PER PIPE RUN SEE DETAIL, SHT. 28 LOWER RAIN GARDEN FOREBAY SEE DETAIL, THIS SHEET FINISHED GROUND PROFILE OVER STORM PIPING (TYP) 27.87 LF 12" HDPE N-12 STORM PIPE @ 6.49% 5.0' (TYPICAL ALL SIDES) 6" (T Y P ) EXCESS RUNOFF OUTLET PIPE (SIZE VARIES, SEE TABLE THIS SHEET) A REINFORCED CONCRETE OUTLET CONTROL STRUCTURE #5 REBAR @ 1.0' O/C E/W (TYPICAL ALL WALLS) 4" SUB-DRAIN DISCHARGE PIPE A 1 4 EXCESS RUNOFF OUTLET PIPE 8" 4" DIA. SLOTTED / PERFORATED PVC UNDERDRAIN PIPE 8" RESERVOIR AGGREGATE LAYER 18" BIOREMEDIATION SAND MEDIA LAYER FLOOR OF RAIN GARDEN WATER QUALITY CAPTURE VOLUME WATER SURFACE (SEE TABLE FOR ELEV.) OUTLINE OF CONCRETE STRUCTURE BENEATH "U" BRACKET HINGE W/ 3/4" S.S. ANCHOR BOLTS (2 REQ'D) WELD EACH BAR ALL AROUND PRIOR TO GALVANIZING 1-1/2" ANGLE IRON FRAME 1" DIA. TRASH RACK BARS 4" MAX. OPENING (TYP) 6" x 2" x 5/8" THICK LOCK-DOWN BAR W/ 2-1/4" x 1/2" SLOT FOR LOCKING TAB, WELDED TO TOP OF TRASH RACK. 2" x 3/8" x 6" LONG LOCKING TAB W/ 1/4" HOLE FOR PAD LOCK, INSET IN CONCRETE, PROJECTING 2-1/2" ABOVE CONCRETE4'-9" 5' 4" DIAPHRAGM AGGREGATE LAYER 3" C L R 4 1 6" W x 12" H x 30" L REINFORCED CONCRETE ENERGY DISSIPATION BAFFLE, CENTERED ON ALIGNMENT OF INFLOW STORM PIPE #5 REBAR @ 6" O/C E/W VARIES (10.0' MAX.) REINFORCED CONCRETE FOREBAY PAN #5 REBAR @ 12" O/C E/W FLOOR OF RAIN GARDEN NON-WOVEN GEOTEXTILE FILTER BLANKET DIAPHRAGM AGGREGATE LAYER 1. 5 ' ± 1" WIDE x FULL DEPTH DRAINAGE SLOTS IN FOREBAY OVERFLOW WEIR 6" 12 " 6" RIP RAP EROSION BLANKET (3' WIDE x 6" DEEP ALONG FULL LENGTH OF OVERFLOW WEIR AND UP THE SIDE SLOPES OF THE RAIN GARDEN TO A HEIGHT APPROX. 6" ABOVE THE TOP OF THE OVERFLOW WEIR.) BIORETENTION SAND MEDIA LAYER 18 " 4" 8" RESERVOIR AGGREGATE LAYER WITH UNDERDRAIN 12" H x 6" W REINFORCED CONCRETE FOREBAY OVERFLOW WEIR 12" HDPE N-12 INFLOWS STORM PIPE W/ FLARED END SECTION 12" 508 6 508 5 508 4 508 3 50 8 2 50 8 1 508 0 50 7 9 50 7 8 5079 5078 5077 5076 REINFORCED CONCRETE FOREBAY FLOOR RIPRAP EROSION PROTECTION BLANKET 6' TOE OF SLOPE 12" 3' RIPRAP EROSION PROTECTION BLANKET SLOTTED CONCRETE OVERFLOW WEIR INFLOW STORM PIPE FES REINFORCED CONCRETE ENERGY DISSIPATION BAFFLE (6" THICK) Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ S T O R M - L I D . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 8 A M PL O T D A T E : 14 ST O R M P L A N & P R O F I L E - L O W E R R A I N G A R D E N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2914 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 0 SCALE:1" = 20' 10'20'40'60' 0 HORIZONTAL SCALE:1" = 20' 10'20'40'60' VERTICAL SCALE: 1"=4' STORM - PLAN LOWER RAIN GARDEN PROFILE STORM - PROFILE LOWER RAIN GARDEN DETAIL - RAIN GARDEN FOREBAY DETAIL - RAIN GARDEN OUTLET CONTROL STRUCTURE (PLAN) DETAIL - OUTLET CONTROL STRUCTURE (SECTION A-A)DETAIL - TRASH RACK (2 REQUIRED) RAIN GARDEN COMPONENT ELEVATIONS & THICKNESS UPPER RAIN GARDEN LOWER RAIN GARDEN Rain Garden Floor Elevation:5076.00 ft.5075.00 ft. WQCV Water Surface / Overflow Weir Sill Elevation:5076.50 ft.5075.75 ft. Outlet Control Structure Invert Elevation:5073.50 ft.5072.50 ft. Bioremediation Sand Media Thickness:18 in.18 in. Diaphragm Aggregate Layer Thickness:4 in.4 in. Reservoir Aggregate Layer Thickness:8 in.8in. 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 TR I A N G L E D R I V E BUILDING F 5088 5090 5089 5088 508 7 508 6 508 5 508 4 508 3 50 8 2 50 8 1 508 0 50 7 9 50 7 8 5079 5078 5077 5076 5076 5077 5078 5078 5077 5076 5075 5074 5079 507 9 5079 507 8 5081 5080 5079 5078 5077 5076 5075 5075 5076 5077 50 7 5 50 7 6 50 7 7 50 7 8 UPPER RAIN GARDEN LOWER RAIN GARDEN FOREBAY UNDERDRAIN PIPING UNDERDRAIN CLEANOUT, (TYP) 10' TYPE "R" INLET STA: 0+20.00 MANHOLE LID-3 STA: 0+36.49 FOREBAY UNDERDRAIN PIPINGUNDERDRAIN CLEANOUT, (TYP) LOWER RAIN GARDEN OUTLET CONTROL STRUCTURE STA: 1+37.52 EXISTING INLET IN TRIANGLE DR. STA: 1+73.52 HDPE FES STA: 2+11.80 MANHOLE LID-1 (4' DIA.) STA: 1+00.0010' TYPE 'R' INLET STA: 0+36.70 UPPER RAIN GARDEN OUTLET CONTROL STRUCTURE STA: 3+92.52 U/S, 3+98.42 D/S MANHOLE LID - 2 (5' DIA.) STA: 5+12.19 5060 5065 5070 5075 5080 5085 5090 5095 5100 5060 5070 5080 5090 5100 0+00 1+00 2+00 4+00 5+00 6+00 7+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 ST A : 3+ 9 2 . 5 2 U / S = 3 + 9 8 . 4 2 D / S ST B : OU T L E T C O N T R O L S T R U C T U R E UP P E R R A I N G A R D E N I N V . 5 0 7 3 . 5 0 ST A : 0 + 3 6 . 7 0 IN V . O U T : 5 0 8 6 . 3 8 10 ' T Y P E " R " I N L E T ST A : 1 + 0 0 . 0 0 MA N H O L E L I D - 1 IN V . I N : 5 0 8 4 . 5 3 IN V . O U T : 5 0 8 4 . 3 1 ST A : 2 + 1 1 . 8 0 IN V . : 5 0 7 6 . 0 0 12 " D I A . H D P E F E S ST A : 5 + 1 2 . 1 9 MA N H O L E L I D - 2 IN V . I N : 5 0 7 2 . 6 9 IN V . O U T : 5 0 7 2 . 6 4 ST A : 6 + 7 3 . 3 5 EX I S T I N G 2 0 ' T Y P E " R " I N L E T IN V . : 5 0 7 0 . 6 9 63.30 LF 12" DIA. HDPE N-12 PIPE @ 2.92% 111.80 LF 12" HDPE N-12 STORM PIPE @ 7.53% UPPER RAIN GARDEN FOREBAY SEE DETAIL SHT. 13 SUB-DRAIN CLEANOUT (TYP) FOR LOCATIONS, SEE PLAN VIEW FLOOR OF RAIN GARDEN ELEV.: 5076.0 1. 9 7 ' CL R FINISHED GROUND PROFILE OVER STORM DRAIN 4" DIAPHRAGM AGGREGATE LAYER 18" BIOREMEDIATION SAND MEDIA LAYER SEE TYPICAL DETAIL, SHT. 28 4" DIA. SLOTTED / PERFORATED PVC UNDERDRAIN PIPE FOR SPECIFICATION, SEE SHT. 28 UPPER RAIN GARDEN PONDING DEPTH = 6" 113.77 LF 18" HDPE N-12 STORM PIPE @ 1.02% 12" DIA. HDPE STORM PIPE STA: 5+51.58 B.O.P. ELEV. 5075.73 161.16 LF 18" DIA HDPE N-12 STORM PIPE @ 1.02% CORE DRILL EAST FACE OF EXISTING INLET BOX TO CREATE OPENING FOR NEW STORM PIPING UPPER RAIN GARDEN OUTLET CONTROL STRUCTURE FOR DETAILS, SEE SHT. 13 8" RESERVOIR AGGREGATE LAYER Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ S T O R M - L I D . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 8 A M PL O T D A T E : 13 ST O R M P L A N & P R O F I L E - U P P E R R A I N G A R D E N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2913 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 0 SCALE:1" = 20' 10'20'40'60' 0 HORIZONTAL SCALE:1" = 20' 10'20'40'60' VERTICAL SCALE: 1"=4' STORM - PLAN UPPER RAIN GARDEN STORM - PROFILE UPPER RAIN GARDEN 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 TR I A N G L E D R I V E 0+00 1+00 2+00 3+00 4+00 5+00 5+99 0+ 0 0 1+ 0 0 BUILDING C BUILDING D BUILDING E BUILDING F BUILDING B TOT-LOT SHELTER SPORT COURT 510 0 509 9 509 8 5097 509 6 509 5 50 8 7 50 8 6 50 8 5 50 8 4 50 8 3 51 0 0 509 9 5099 50 9 8 50 9 7 50 9 5 50 9 4 50 9 3 50 9 2 50 9 1 50 8 9 50 8 8 50 8 7 50 8 6 50 8 6 50 8 5 50 8 4 50 8 3 0+ 0 0 1+ 0 0 2+ 0 0 3+ 0 0 5070 5075 5080 5085 5090 5095 5100 5105 5110 5115 5070 5080 5090 5100 5110 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 EA S T P R O P E R T Y L I N E PVI STA: 4+98.00 PVI ELEV: 5082.90 LVC: 100.00 BV C S : 4 + 4 8 . 0 0 BV C E : 5 0 8 5 . 0 8 EV C S : 5 + 4 8 . 0 0 EV C E : 5 0 8 1 . 4 0 PVI STA: 1+10.00 PVI ELEV: 5099.82 LVC: 100.00 BV C S : 0 + 6 0 . 0 0 BV C E : 5 0 9 8 . 8 3 EV C S : 1 + 6 0 . 0 0 EV C E : 5 0 9 7 . 6 4 DRIVE AISLE CENTERLINE PROFILE EXISTING GROUND PROFILE ALONG DRIVE AISLE CENTERLINE K = 15.75 K = 73.53 4+ 6 8 . 0 0 50 8 4 . 2 4 4+ 8 8 . 0 0 50 8 3 . 4 4 5+ 0 8 . 0 0 50 8 2 . 7 1 5+ 2 8 . 0 0 50 8 2 . 0 3 0+ 8 0 . 0 0 50 9 9 . 0 9 1+ 0 0 . 0 0 50 9 9 . 1 1 1+ 2 0 . 0 0 50 9 8 . 8 7 1+ 4 0 . 0 0 50 9 8 . 3 8 ST A = 5 + 6 2 . 4 3 1.99% -4.36 % ST A = 0 + 3 3 . 0 0 EL E V = 5 0 9 8 . 2 9 EL E V = 5 0 8 0 . 9 7 -3.00% 7' SIDEWALK 17' PARKING 24' DRIVE AISLE 12' TRAVEL LANE 12' TRAVEL LANE 5' GARAGE APRON 3' CONCRETE VALLEY PANVERTICAL CURB W/ 18" GUTTER, (TYP) Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ R O A D - P P . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 8 A M PL O T D A T E : 15 WE S T A C C E S S D R I V E P L A N & P R O F I L E 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 0 SCALE:1" = 40' 20'40'80'120' 2915 SEE PLAN 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: HORIZONTAL SCALE WEST ACCESS DRIVE ROAD PROFILE WEST ACCESS DRIVE ROAD PLAN TYPICAL INTERIOR DRIVE AISLE SECTION W/ GARAGE N.T.S. 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 TRIANGLE DRIVE A V O N D A L E R O A D 0+ 0 0 1+ 0 0 2+ 0 0 0+00 1+00 2+00 3+0 0 4+ 0 0 4+ 5 9 BUILDING B BUILDING A 50 9 9 50 9 8 50 9 7 50 9 6 50 9 5 50 9 9 50 9 9 509 8 5097 5080 5085 5090 5095 5100 5105 5110 5115 5080 5090 5100 5110 -1+50 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 -1+50 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 1.98%-4.26 % -1.00% 1.00% PVI STA: 1+88.11 PVI ELEV: 5091.49 LVC: 100.00 BV C S : 1 + 3 8 . 1 1 BV C E : 5 0 9 3 . 6 2 EV C S : 2 + 3 8 . 1 1 EV C E : 5 0 9 0 . 9 9 PVI STA: 3+73.10 PVI ELEV: 5089.64 LVC: 50.00 BV C S : 3 + 4 8 . 1 0 BV C E : 5 0 8 9 . 8 9 EV C S : 3 + 9 8 . 1 0 EV C E : 5 0 8 9 . 8 9 PVI STA: 0+37.00 PVI ELEV: 5097.92 LVC: 50.00 BV C S : 0 + 1 2 . 0 0 BV C E : 5 0 9 7 . 4 3 EV C S : 0 + 6 2 . 0 0 EV C E : 5 0 9 6 . 8 6 ST A = 0 + 0 0 . 0 0 EL E V = 5 0 9 7 . 1 9 ST A = 4 + 2 1 . 2 8 EL E V = 5 0 9 0 . 1 2 EL E V = 5 0 8 9 . 9 8 PR O P E R T Y L I N E / B . O . W . ST A = 4 + 5 9 . 2 8 C/ L A V O N D A L E R D . V.C. CENTERLINE INT. STNS & ELEVS 0+22.00 5097.57 0+32.00 5097.58 0+42.00 5097.47 0+52.00 5097.23 1+ 5 8 . 1 1 50 9 2 . 8 3 1+ 7 8 . 1 1 50 9 2 . 1 8 1+ 9 8 . 1 1 50 9 1 . 6 5 2+ 1 8 . 1 1 50 9 1 . 2 5 V.C. CENTERLINE INT. STNS & ELEVS 3+58.10 5089.81 3+68.10 5089.77 3+78.10 5089.77 3+88.10 5089.81 K= 8.01 K= 30.67 K= 25.00 DESIGN CENTERLINE PROFILE Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ R O A D - P P . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 9 A M PL O T D A T E : 16 WE S T T O E A S T D R I V E P L A N & P R O F I L E 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 0 SCALE:1" = 40' 20'40'80'120' 2916 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L WEST to EAST ACCESS DRIVE ROAD PROFILE WEST to EAST ACCESS DRIVE ROAD PLAN NORTH HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: HORIZONTAL SCALE 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 AVOND A L E R O A D 5065 5070 5075 5080 5085 5090 5095 5065 5070 5080 5090 0+00 1+00 2+00 3+00 4+00 0+00 1+00 2+00 3+00 4+00 EMERGENCY ACCESS CENTERLINE PROFILE EXISTING GROUND PROFILE ALONG EMERGENCY ACCESS CENTERLINE 2.74% 1.00% BV C 1 + 5 5 . 0 0 50 8 4 . 7 8 1+ 6 5 . 0 0 50 8 4 . 5 4 1+ 7 5 . 0 0 50 8 4 . 3 8 VP I 1 + 8 0 . 0 0 50 8 4 . 1 0 1+ 8 5 . 0 0 50 8 4 . 2 9 1+ 9 5 . 0 0 50 8 4 . 2 8 EV C 2 + 0 5 . 0 0 50 8 4 . 3 5 2.00% BA C K O F W A L K 2 + 3 4 . 4 4 50 8 4 . 6 4 50' VERTICAL CURVE VPI STA: 1+80.00 VPI ELEV: 5084.10 K = 13.37 BA C K O F W A L K 1 + 3 6 . 0 0 50 8 5 . 3 0 EN D O F H A M M E R H E A D FL O W L I N E 0 + 3 8 . 0 0 50 8 6 . 1 7 WE S T F L O W L I N E 1 + 1 2 . 0 0 50 8 4 . 1 5 EA S T F L O W L I N E 0 + 8 8 . 0 0 50 8 4 . 7 2 4+ 0 0 5+ 0 0 BUILDING E BUILDING F 5087 5086 5085 5084 5083 5087 5086 5086 5085 508 4 508 3 0+00 1+00 2+00 3+00 3+25 Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ R O A D - P P . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 9 A M PL O T D A T E : 17 EM E R G E N C Y A C C E S S P L A N & P R O F I L E 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2917 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 0 SCALE:1" = 40' 20'40'80'120' EMERGENCY ACCESS ROAD PROFILE EMERGENCY ACCESS PLAN NORTH HORIZONTAL SCALE: 1" = 40' VERTICAL SCALE: 1" = 4' 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 EMERGENCY T R I A N G L E D R I V E ACCESS BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F BUILDING A DOG PARK SHELTER SPORTS COURT TOT-LOT BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F AV O N D A L E R O A D BUILDING A WO O D R O W DR I V E TR I A N G L E D R I V E TYPE III BARRICADE INSTALL ENHANCED CROSSWALK EXISTING STRIPING, (TYP) EXISTING CHEVRON ARROW SIGNS 18.2 ' 23. 6 ' 26.2 ' 12' SIGN ON ACCESS GATE TO FACE TRIANGLE AVENUE A BB B B F G E D G G H A H J J B B B B C K K J L L L L L L L L L L L L L L L L L L L L L L L L L Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ H O R I Z O N T A L . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 9 A M PL O T D A T E : 18 SI G N I N G & S T R I P I N G P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O NORTH 0 SCALE:1" = 30' 15'30'60'90'2918 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L SIGN LEGEND: R1-2 YIELD SIGN 36"X36"X36" WITH STREET NAME SIGNS ABOVE W-11-2 "PED XING" SIGN 30"X30" AND W16-7P "ARROW" SIGN 24"X18" (AS DIRECTED BY THE LOCAL ENTITY ENGINEER) "NO PARKING ANYTIME" SIGN 1. SEE SHEET 27 FOR STANDARD SIGN DETAILS 2. FIRE LANE STRIPING AND SIGNAGE SHALL MEET LCUASS AND IFC STANDARDS. NOTES: STRIPING LEGEND: SOLID DOUBLE YELLOW 4" WIDE SOLID WHITE LINE 6" WIDE SOLID WHITE LINE 8" WIDE DO NOT ADD THE WHITE DASHED LINE THAT DELINEATES THE OUTER EDGE OF THE ROUNDABOUT AS IT EXISTS ON THE OTHER 3 LEGS "NO PARKING ANYTIME" SIGN ONE WITH ARROW POINTING EAST AND ONE WITH ARROW POINTING WEST "EMERGENCY ACCESS ONLY" SIGN 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 "STOP" SIGN "NO PARKING-FIRE LANE" SIGN RED PAINTED CURB, SEE SHEET 27 L K H D C B A G F E J 1' M I N . BE D D I N G Z O N E 14th O . D . / 4 " M I N . TRENCH BACKFILL BEDDING ZONE (SEE ABOVE) CASING PIPE STAINLESS STEEL WITH POLYMER CASING CHOCKS PIPE JOINT RESTRAINT MAX. SPACING FROM PIPE JOINT 12"12" CARRIER PIPE EACH BARREL SECTION OF PIPE WITHIN THE CASING SHALL HAVE A MINIMUM OF (3) CASING CHOCKS. THE MIDDLE CHOCK SHALL BE CENTERED BETWEEN EACH PIPE JOINT. 1. NOTES: MAGNESIUM ANODE INSTALLED IN NATIVE SOIL, A MINIMUM OF 3 FEET FROM CASING. PLACE THE TOP OF THE ANODE BELOW THE CENTERLINE OF THE CASING, AS REQUIRED. CASING LENGTH PER PLAN DOUBLE STAINLESS STEEL BAND (TYP.) LEAD WIRE (10' MIN.) RUBBER CASING SEAL (TYP) EACH END PROVIDE CATHODIC PROTECTION TEST STATION STEEL CASING CARRIER PIPE TRACER WIRE ANODE LEADS BLACK PIPELINE TEST WIRES RED FOR STEEL BLUE FOR DI CASINGS ORANGE REF ELECTRODE YELLOW TRACER WIRE WHITE 1/2" MAXIMUM CASING WIRE 0.01 OHM HOLOWAY SHUNT ANODE CASING WIRE REFERENCE TRACER WIRE (BUNDLED) 4'-0" I.D. 4'-0" 1' MIN. COVER 4" TYP Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 1 8 S E W E R D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 2 9 A M PL O T D A T E : 19 SE W E R D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2919 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 FORT COLLINS ONLY Ar e a t o b e l a n d s c a p e d Co n c . S i d e w a l k LP 0. 5 ' 6. 0 ' 4. 5 ' Tr u n c a t e d D o m e Wa r n i n g P a n e l Se c t i o n A - A NT S 0. 5 ' Gu t t e r 1: 2 0 S l o p e 1: 1 2 M A X S l o p e Va r i e s pa n e l s : R2 0 . 0 ' R1 5 . 0 ' 12 . 0 ' 4. 5 ' Fu l l h e i g h t C u r b 12 . 0 ' PL A N V I E W NT S PT Curb 4. 5 'A 0" C u r b Ramp Ar e a La n d s c a p e d Fl a r e Gu t t e r 1- 2 ' x 2 ' 1- 2 ' x 2 . 5 ' Ra m p Ra m p R1 9 . 5 ' PL A Conc. Sidewalk PL Co n c . F l a r e Fl o w l i n e 0. 5 ' 4. 5 ' Cu r b 6. 0 ' De t e c t i o n P l a n L o c a t i o n s Tr u n c a t e d D o m e W a r n i n g Tr u n c a t e d d o m e 1. 5 ' 1. 5 ' 6" C u r b 0" C u r b 6" C u r b &Ba c k o f W a l k PT o f W a l k Tr u n c a t e d d o m e Fl a r e wa r n i n g d e t e c t i o n PT o f c u r b r e t u r n BO C - B a c k o f c u r b - P r o p e r t y L i n e P T - P o i n t o f T a n g e n c y 2' - 0 " L 4' - 6 " PLE G E N D : 2' - 0 " 2' - 6 " Va r i e s 6" Cu r b or Pa n e l s Ap r o n Pa n e l s Flow line Curb and Gutter 5' - 6 " B O C t o w a l k w / v e r t i c a l c u r b 5' - 7 " B O C t o w a l k w / d r i v e o v e r c u r b Co n c . F l a r e No t e : 1 . S e t r a m p s l o p e s u s i n g t h e c e n t e r o f t h e r a m p . 2 . T r u n c a t e d d o m e w a r n i n g p a n e l : I n s t a l l p a n e l s a l o n g w i t h t h e co n c r e t e p o u r f o r t h e r a m p . T h e p a n e l m a t e r i a l s h a l l b e " C a s t I n Ta c t W a r n i n g P a n e l s " o r a n e q u i v a l e n t m a t e r i a l t h a t m u s t b e f i r s t ap p r o v e d b y t h e C i t y E n g i n e e r , p r i o r t o i n s t a l l a t i o n . T h e p a n e l co l o r s h a l l b e r e d , n o o t h e r c o l o r i s a p p r o v e d . S p e c i f i c a t i o n s f o r th e p a n e l m a t e r i a l w i l l b e p r o v i d e d u p o n r e q u e s t . 3 . E a c h r a m p s h a l l a l i g n p e r p e n d i c u l a r t o t h e s t r e e t i n w h i c h th e r a m p i s p r o v i d e d t o c r o s s . 4 . R e f e r t o s t a n d a r d d r a w i n g 1 6 0 6 i n t h e L a r i m e r C o u n t y u r b a n ar e a s t r e e t s t a n d a r d s f o r o t h e r n e c e s s a r y c r i t e r i a n e e d e d t o co n s t r u c t t h e s e r a m p s t h a t i s n o t s p e c i f i e d o n t h i s d r a w i n g . 5 . C o n s t r u c t t h e r a m p s a n d w a l k s o t h e c o r n e r a r e a a l l d r a i n s t o th e s t r e e t . 1:12 max. X=2' min.Driveway Width Varies 2' - 0 " 6" Attached Sidewalk Lip FL Back of curb Right of Way line Detached Attached Right of W a y L i n e Detached Sidewalk 1: 2 4 ( m a x . ) NOTE: 1. Concrete driveway must be provided to the property line. Refer to Chapter 25 for minimum removal dimensions. X Y W X Y W = Width 1: 1 2 ( m a x . ) P r o p e r t y L i n e t 1/4" PER FT. N.T.S. SECTION A-A 2" t 1:12 (max.) t X = Curb Transition Length Y = Parkway Width in Type I Approach W = Driveway Width (See Drawing 707) t = Concrete Thickness - minimum 6" Type I = With Detached Sidewalk Type II = With Attached Sidewalk TYPE I TYPE II 1: 1 2 ( m a x . ) 1: 4 8 A A PERSPECTIVE X=6'-0" 1:48 SLOPE 1:12 max. B B WALK Y t t WALK t 2" FL O W L I N E JOINT EXPANSION BO W 1:12 (max.) 1:24 SECTION B-B N.T.S. Ramp if necessary 1:12 max. Expansion joint if drive continues as concrete WALK 6" (m a x . ) 1/ 2 " 2" R . N.T.S. INFLOW CURB AND GUTTER N.T.S. OUTFALL CURB & GUTTER2' VALLEY PAN DETAIL N.T.S. FL N.T.S. 2' CURBED CHANNEL PRIVATE DRIVE/PARKING DETAILS N.T.S. PRIVATE DRIVE SIDEWALK CHASE 5/8" GALV. STEEL PLATE 3/8" BRASS SCREW 18" O.C. WITH COUNTERSUNK HEAD FLUSH WITH PLATE 2.0'OPENING EDGE OF STREET BACK OF CURB 3" TYP.FLOW LINE SL O P E 6"X6" - 10/10 W.W.F. 12" 6" 6"2.0'6" 3.0' 12" 6" 4.5" 6" 1" 12" 1.5" 1.5"R 1.5"R 6" 12"12" 1" 6"X6" - 10/10 W.W.F. 6" 1" 1'-6" 6"1.5"R 2"R 6" 6" 12" 6" 2"R.2" 6" 6" 12 " 1 1/2"R. 2'-6" 6" 4 1/2" VERTICAL Gutter edge may be tapered or battered. (Typical for all Curb & & Gutter Types) 8 5 / 8 " 1 3 / 8 " 3 3 / 8 " 14"17" 31" FL R 1 6 " R1 6 " 7 1 / 4 " DRIVE-OVER CURB & GUTTER Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 1 9 S T R E E T D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 0 A M PL O T D A T E : 20 ST R E E T D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2920 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 Final asphalt lift, overlay or grade adjustment Depress ring 1/4" to 5/8" below adjacent finished street grade Slope up to match finished pavement Straight cut around ring Concrete grade ring to match slope or finished grade Grade ringExisting base course Manhole Shim / Grout 16 " m a x . NOTE: 1. Grout shall be a mixture of 100 lbs Grout mix, 26 lbs water (3.12 Gal), and 100 lbs of sand conforming to ASTM C-35. 2. Manholes shall not be located in crosspans, gutters, or wheel path. 3. Shim and grout to make ring and cover flush with the finished pavement surface. Cover Support with Steel Shims and pack with High Strength Grout 3' - 0 " 2' - 0 " PVC Conduit 15'-0" NOTES: 1. Match location of sleeves on curb head. 2. Depth of sleeve shall be no less than 3'-0" below street grade. 3. Bundles of sleeves are permitted. 4. Sleeves shall be installed with "Pull Wires". A A Score concrete curb head with "X" to mark location of sleeves. SECTION A-A (M I N . ) (M I N . ) DETAIL Sidewalk Base Bundles of Conduits permitted (Schedule 40 min.) 1' Sleeve 1' Sidewalk Driveway LIP F.L. T.C. DRIVEWAY SIDEWALK SECTION A-A NOTE: 1. Sidewalk grade shall remain consistent across driveway 3. This detail applies to Residential & Commercial driveways. 6" 6" Residential Detached Sidewalk Attached Sidewalk 1/2" Expansion Joint Material 1/2" Expansion Joint Material A A 2. For driveway design requirements, see CONST. DWG. 706 & 707. ATTACHEDDETACHED 3'-0"6'-0" All Sidewalk Thickness Shall Be 6" minimum. Min. SIDEWALK 8" Commercial Cu r b Fl a r e Varies Cu r b 2' - 0 " Fl a r e Ra m p co n c r e t e r a m p s Pa n e l s e m b e d d e d i n t h e Ap r o n Gu t t e r or Curb and Gutter Flow line1: 2 0 S l o p e 1: 1 2 M A X S l o p e Se c t i o n A - A NT S Va r i e s Va r i e s Cu r b Curb Fl a r e Ra m p 2'-0 " Varies Pa n e l s Pa n e l s 6" AA CLPedestrian flow Aligned with Ra m p Wi d t h : 4. 5 ' 5. 0 ' 6. 0 ' 7. 0 ' 8. 0 ' No t e : Tr u n c a t e d d o m e p a n e l s a r e av a i l a b l e i n 2 ' x 2 ' s q u a r e s a n d 2' x 2 . 5 ' r e c t a n g l e s . C o m b i n e th e w i d t h s t o f i t t h e r a m p . Pa n e l s m a y b e c u t t o n o l e s s th a n a 2 ' x 1 . 5 ' s i z e . Pa n e l W i d t h Co m b i n a t i o n s : 2' + 2 . 5 ' 2. 5 ' + 2 . 5 ' 2' + 2 ' + 2 ' 2. 5 ' + 2 ' + 2 . 5 ' 2' + 2 ' + 2 ' + 2 ' No t e : 1 . T r u n c a t e d d o m e w a r n i n g p a n e l : I n s t a l l p a n e l s a l o n g w i t h t h e c o n c r e t e p o u r f o r t h e r a m p . T h e p a n e l m a t e r i a l s h a l l b e " C a s t I n T a c t W a r n i n g P a n e l s " o r a n e q u i v a l e n t m a t e r i a l t h a t m u s t b e f i r s t a p p r o v e d b y t h e C i t y E n g i n e e r p r i o r t o i n s t a l l a t i o n . T h e p a n e l c o l o r s h a l l b e r e d , n o o t h e r c o l o r i s a p p r o v e d . S p e c i f i c a t i o n s f o r t h e p a n e l a n d i n s t a l l a t i o n i n s t r u c t i o n s w i l l b e p r o v i d e d u p o n r e q u e s t . 2 . T h i s d r a w i n g s h o w s v e r t i c a l c u r b . F o r D r i v e O v e r C u r b t h e w a r n i n g d e t e c t i o n l o c a t i o n s h a l l b e p l a c e d i n t h e s a m e p o s i t i o n 6 " b a c k f r o m t h e F a c e o f C u r b o r . Ca s e 1 - D i r e c t i o n a l R a m p s Ca s e 2 - N o n - D i r e c t i o n a l R a m p s Varies Pa n e l s Ra m p Pa n e l s Fl a r e 2' - 0 " Cu r b Ca s e 3 - M i d - B l o c k R a m p s 6" Pa n e l s Pa n e l s Ap r o n Gu t t e r or Fl a r e 6" Fl a r e (C e n t e r l i n e o f r a m p ) CL BO C BO C BO C FO C FLor FL FO C BO C LF -B a c k o f C u r b -F a c e o f C u r b -F l o w l i n e 2' FORT COLLINS ONLY 1. NO JOINTS ARE ALLOWED IN THE FLOWLINE. SIX INCH WIDE CURB OR "DUMMY JOINT" MAY BE TOOLED NO CLOSER THAN 6 INCHES FROM FLOW LINE AS SHOWN. 2. MINIMUM CONCRETE THICKNESS IS 6 INCHES. 3. JOINT PATTERN TO BE ACCORDING TO 'INTERSECTION GUTTER DETAIL' OR AS DETERMINED BY THE LOCAL ENTITY. 4. WOOD FLOAT FINISH IS REQUIRED OVER THE SLOPED SURFACE OF RAMP AND FLARES. 5. A 6 INCH WIDE CURB MAY BE POURED AT THE BACK OF THE RAMP AS SHOWN IF REQUIRED. IF CURB IS USED IT SHALL MATCH THE CURB AND GUTTER STYLE OF ADJACENT CURB AND GUTTER. 6. MINIMUM RAMP WIDTH SHALL BE FOUR FEET, OR THE SAME AS THE WIDEST ADJACENT SIDEWALK, WHICHEVER IS GREATER, UP TO A MAXIMUM WIDTH OF 8 FEET. 7. THE RAMP LANDING MAY BE POURED MONOLITHIC WITH THE ADJACENT TRANSITIONS PROVIDED THAT AN APPROVED "SHAKE-ON" PIGMENT BE USED TO COLOR THE LANDING AREA. 8. T= THICKNESS (AS SPECIFIED ON PLANS OR LOCAL ENTITY ENGINEER). NOTES: -C e n t e r l i n e o f r a m p Transition back of walk (typ.) Broom finishBroom finish * SECTION A-A MID-BLOCK LOCATION (min.) 6' 1:12 Slope (max.) 1:25** slope (max.) Fl o w l i n e (min.) (max.) Slope 1:12 5' A Sl o p e 1: 2 5 (m a x . ) 6' Wood float finish thru ramp Slo p e 1:1 2 Slope 1:12 CORNER LOCATION ramp finish thru Wood float Broom finish A (min . ) 6' 1:25 (ma x . ) Slop e (max . ) A A 4' (m a x ) (Radius varies) (typ.) back of walk Transition 2 Br o o m f i n i s h 6" * BA C K O F W A L K / L A N D I N G Curb (optional) 6" (m i n . ) (m i n . ) 6" Walk Curb Gutter NOTES: 1. * 6" Thickness applies to entire ramp area. 2. ** 1:25 Unless a landing behind ramp (then ramp can be 1:12 with 1:20 on the truncated dome warning.) 3. See CONST. DWG. 1606(a) and 1607 for Fort Collins. 4. See CONST. DWG. 1614, 1615 and 1616 for Loveland. 2'-0"6" Walk Gutter Curb Only if needed (m i n . ) 6' (mi n . ) or s a m e wid t h a s the w i d e s t wal k 6' ( m a x . ) walk, if needed. ground behind the Curb to retain Warning Detection Truncated Dome at the corners of the truncated dome warning curb 0" curb 6" cu r b 0" curb 6" truncated dome warning detection Warning Detection Truncated Dome 7 3/8" (L)1 3/8" 17 " 6" 3 3/8" 14 " FL R 16" R 16" DR I V E - O V E R C U R B , G U T T E R A N D D E T A C H E D S I D E W A L K 31 " Se e D r a w i n g 1 6 0 1 10 3/4"(L) R 16" DR I V E - O V E R C U R B , G U T T E R A N D A T T A C H E D S I D E W A L K 18 " 18 " 3 3/8" 1 3/8" 6" R 16" FL 14 " 6" 17 " 1 1 / 2 " 5' ( L ) 8 5/8" (F.C.) 7 1/4" F.C. 12" (F.C.) Sl o p e t o c u r b 1 / 4 " / F t . 1' m i n . ( F . C . ) 48 : 1 m i n . 4: 1 m a x . Ex c a v a t i o n Fi l l 1' m i n . 2' m i n . 1/ 4 " / F t . CU R B & G U T T E R I N A C U T O R F I L L 6" 3' - 9 " ( F . C . ) Fo r T h i c k n e s s 2' m i n . ( L ) Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 0 S T R E E T D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 1 A M PL O T D A T E : 21 ST R E E T D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2921 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 IN. MIN. SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 60 IN.18 IN. TO 30 IN. 72 IN.OVER 30 INCHES MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 F T . M I N . D E P T H CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 I N . M I N . 48 I N . M A X . VA R I A B L E 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN GENERAL NOTES A A B B SECTION A-A SECTION B-B SLOT DETAIL PLATE DETAIL HOLD DOWN ALTERNATE SLOT AND DETAIL GRATE INSTALLATION PLAN LEGEND AA ABBREVIATIONS OUTLET PIPE D H MIN. Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 1 S T O R M D R A I N D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 1 A M PL O T D A T E : 22 ST O R M D R A I N D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2922 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 UNDERDRAIN PIPE AND FITTING DETAILS INLINE DRAINS ADS NYLOPLAST INLINE DRAIN WITH 12" X 12" DUCTILE IRON FRAME AND GRATE TEE, OFFSET LATERAL & ELBOW AS NECESSARY PER PLAN RISER AND PIPE: 12" DIA. ADS N-12 PIPE 12" DIA. RISER (TYP) ELBOW, ADS 1299ST Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 2 S T O R M D R A I N D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 2 A M PL O T D A T E : 23 ST O R M D R A I N D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2923 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 4"-6" 5'0" MIN 45° 2'-0" 5'-0" TYPICAL 1'-0" 1'-6" 1' M I N . BE D D I N G Z O N E 14th O . D . / 4 " M I N . TRENCH BACKFILL BEDDING ZONE (SEE ABOVE) GENERAL NOTES: 1. Bearing surface areas shown in chart are minimum. 2. All fittings to be wrapped with polyethylene. 3. Data in table is based on a pipeline test pressure of 150 psi (min.) and a soil bearing capacity of 1,000 lb/sq. ft. Adjust the dimensions as required to suit the field conditions encountered by Engineer. 4. Thrust blocks on pipe larger than 12 inches diameter shall be designed for conditions existing at the installation site. 5. Refer to Section 03300 and 02713. Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 3 W A T E R D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 3 A M PL O T D A T E : 24 WA T E R D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2924 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 CP TEST STATION WJEI USA ASU IEJW STATION LOCATOR LID PLAN VIEW LID SECTION VIEW VALVE BOX SECTION VIEW 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 STREET ST R E E T 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 4 W A T E R D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 3 A M PL O T D A T E : 25 WA T E R D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2925 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 FLOW ROCK 4"-6" LF DITCH 2:1 O R F L A T T E R h/2 6" (EXCEPT AT TRICKLE PAN) FILTER GEOTEXTILE OUTLET STRUCTUREh 1.0 x h Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : sa r a Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 5 E R O S I O N C O N T R O L D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 4 A M PL O T D A T E : 26 ER O S I O N C O N T R O L D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2926 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 Max. Sign Panel 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. Cross section of post 3" - 6" ABOVE GRADE 2 1/4" Anchor 3. Signs larger than 36 inches in length or width require wind bracing and special post design. NOTES: 4. Anchor Stub and post are square steel tube (perforated). Anchor/Stub Post Size CRITERIA FOR SINGLE POST 36" x 36"2.25" x 2.25" x 3'-0"2" x 2" x 12'-0" 5. All "No Parking" signs shall be installed at 45° from Flow Line. ** 2" x 2" x 10' OR 12' 12 GAUGE TELESPAR POST (22F12A31) 7' - 0 " M I N . C L E A R A N C E 2' - 3' FROM F Street Curb See Figure 16-1 SW SAMPLE AVE 2400 R1-1 "STOP" SIGN 30" HIGH DENSITY/DIAMOND GRADE. SIGN MOUNTED TO POST WITH 1 EACH DRIVE RIVET WITH NYLON WASHER AGAINST SIGN FACE (ON TOP OF THE SIGN). THE BOTTOM OF THE SIGN SHALL BE MOUNTED WITH 1 EACH 5/16"x2-1/2" HEW BOLT WITH METAL AND FROM NYLON WASHERS (NYLON WASHER AGAINST SIGN FACE) AND SECURED WITH 1 EACH 5/16" HEX NUT ON THE BACK SIDE OF POST.L 2-1/4" x 2-1/4" x 3' ANCHOR/STUB 2 EACH 8" BLADES MOUNTED TO POST WITH 4 EACH DRIVE RIVETS WITH NYLON WASHERS *12 Gauge 30 " 8" 8" SW SA M P L E AV E NO T E S : 1. S t r e e t n a m e m u s t b e 6 " ( m i n . ) c a p i t a l w h i t e l e t t e r s , F H W A S e r i e s " B " . 2. P r e f i x m u s t b e 2 " l e t t e r s , F H W A S e r i e s " B " a n d p l a c e d o n t h e u p p e r l e f t . 3. S u f f i x m u s t b e 2 " ( m i n . ) l e t t e r s a n d b l o c k n u m b e r m u s t b e 2 " ( m i n . ) n u m b e r s , F H W A S e r i e s " B " . 4. O v e r a l l s i g n l e n g t h d i m e n s i o n v a r i e s a c c o r d i n g t o l e n g t h o f s t r e e t n a m e . 5. A l l s i g n l e t t e r i n g a n d g r e e n b a c k g r o u n d m a t e r i a l m u s t b e a t l e a s t D i a m o n d G r a d e s h e e t i n g p e r F H W A ; No s i l k s c r e e n e d s i g n s w i l l b e p e r m i t t e d . 6. S t r e e t n u m b e r s s h a l l a l w a y s p o i n t t o h i g h e r b l o c k n u m b e r . 7. A l u m i n u m s i g n b l a n k s h a l l b e 0 . 1 0 t h i c k n e s s w i t h 3 / 4 " r a d i u s c o r n e r s . 8. L o v e l a n d o n l y , s i g n a l i z e d i n t e r s e c t i o n s i g n s s h a l l b e 1 8 " ( m i n . ) i n h e i g h t . 9. A l l s t r e e t n a m e s i g n s s h a l l b e r e t r o r e f l e c t i v e . 24 0 0 Len g t h V a r i e s b y S t r e e t N a m e 8" 1/2" 2-1/4" 1/2" 2-34" 1/2" 2- 1 / 2 " H w y B S e r i e s 1" min. 2" max. 6" H w y B S e r i e s 2- 1 / 2 " H w y B S e r i e s , Ce n t e r e d o n L o g o 3-3/4" 2-3/4" 1" min. 2" max. 1/2" 1/2" 1/2" VA N - AC C E S S I B L E PA R K I N G MI N . MI N . ON E I N E V E R Y EI G H T A C C E S S I B L E SP A C E S , B U T N O T LE S S T H A N O N E , SH A L L B E V A N AC C E S S I B L E . ON E S I G N PE R S P A C E RE Q U I R E D RE Q U I R E D PE R S P A C E ON E S I G N RE Q U I R E D PE R S P A C E ON E S I G N CA R A C C E S S I B L E VA N A C C E S S I B L E "U N I V E R S A L D E S I G N " CA R & V A N A C C E S S I B L E OR A " U N I V E R S A L " P A R K I N G S P A C E D E S I G N M A Y B E U S E D . TH I S D E S I G N I S U S E D T O A C C O M M O D A T E C A R & V A N AC C E S S I B L E P A R K I N G S P A C E S , W H I C H E L I M I N A T E S T H E NE E D F O R T W O S I G N T Y P E S . 8' 5' 8' 8' 8' 8' 11 ' 5' 11 ' 11 ' 5' RE S E R V E D RE S E R V E D PA R K I N G RE S E R V E D PA R K I N G R7 - 8 R7 - 8 R7 - 8 ANY TIME R7-9a 12" 18 " 1 1/2" 3/ 83/ 8 4 7 / 8 " 3 7/8" 1" 6" MUTCD Designation COLOR SCHEDULE BACKGROUND "P" RED WHITE BLACK LEGEND, CIRCLE DIAGONAL, BORDER, "ARROW", "ANY TIME" Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ H O R I Z O N T A L . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 4 A M PL O T D A T E : 27 SI G N I N G & S T R I P I N G D E T A I L S 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2927 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 AV O N D A L E R O A D WO O D R O W DR I V E TR I A N G L E D R I V E HP? BUILDING B BUILDING C BUILDING D BUILDING E BUILDING F UPPER RAIN GARDEN LOWER RAIN GARDEN FFE 5100.30 FFE 5094.20 FFE 5089.00 FFE 5084.35 FFE 5095.50 FFE 5092.50 FFE 5099.37 FFE 5099.52 FFE 5099.37 FFE 509 4 . 2 5 FFE 509 3 . 7 5 FFE 509 3 . 2 5 FFE 509 2 . 7 5 FFE 509 2 . 2 5 FFE 509 1 . 7 5 FFE5091.9 5 FFE5091.7 5 FFE5091.5 5 FFE5091.3 5 FFE5091.1 5 FFE5090.9 5 SHELTER SPORT COURT DOG PARK TOT-LOT BUILDING A Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ C 3 D _ L I D . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 4 A M PL O T D A T E : 28 LI D P L A N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2928 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NORTH 0 SCALE:1" = 30' 15'30'60'90' LEGEND: RAIN GARDEN MEDIA GENERAL NOTES: 1. THESE LID (LOW IMPACT DEVELOPMENT) PLANS SHALL BE READ IN CONJUNCTION WITH THE LANDSCAPE, DRAINAGE AND GRADING PLANS FOR A COMPLETE SET OF PLANS. NOTES: 1. WATER QUALITY CAPTURE VOLUME IS CALCULATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL. 2. REQUIRED LID TREATMENT VOLUME CALCULATED TO BE THE RUNOFF FROM 75% OF THE IMPERVIOUS AREAS IN THE DRAINAGE SUB-BASIN SERVED BY THE LID FACILITY, IN ACCORDANCE WITH SECTION 3.1(a) OF VOLUME 3, CHAPTER 2, SECTION K OF THE FORT COLLINS AMENDMENTS, PER ORDINANCE NO. 007,2016. 61 1 2 E . S i e n n a B o u q u e t P l . Ca v e C r e e k , A Z 8 5 3 3 1 4" 2" MIN8" MIN 18" MIN 30 " M I N 12" MAX 4" MIN DIAMETER PERFORATED PVC UNDERDRAIN GEOTEXTILE FABRIC OR LINER (AS PER PLAN) FLAT AREA - SEE DESIGN PLANS FOR EXTENTS OF BIORETENTION FLAT SURFACES NATIVE SOIL ZONE 8" MIN DEPTH OF RESERVOIR AGGREGATE 4" MIN DEPTH OF DIAPHRAGM AGGREGATE 18" MIN DEPTH OF BIORETENTION SAND MEDIA RUNDOWN OR SCOUR PROTECTION NEEDED ON STEEP SLOPES MAXIMUM ALLOWABLE PONDING DEPTH IS 12" FROM THE TOP OF THE MULCH LANDSCAPING TO BE INSTALLED PER APPROVE LANDSCAPING PLAN FLAT 4 MAX 1 Sheet: Of: Date: Job No: Drawn: Design: Scale: Checked: NO DA T E BY CH K RE V I S I O N S DE S C R I P T I O N 123456 66 1 4 E . B r i l l i a n t S k y , D r . Sc o t t s d a l e , A Z 8 5 2 6 6 Ph o n e : ( 3 0 3 ) 9 1 3 - 5 3 8 2 la r r y c o w e n @ c o m c a s t . n e t OW E N CO N S U L T I N G GR O U P , I N C . DR A W N B Y : da v i d Z: \ S h a r e d \ P r o j e c t s \ 1 1 1 O w e n C o n s u l t i n g \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s N o r t h \ A u t o C A D \ 1 1 1 - 2 0 0 1 F C R i d g e w o o d H i l l s T r a c t B M A - 0 2 \ D W G \ F U P \ 2 8 L I D - D E T A I L S . d w g FI L E L O C A T I O N : 12 / 2 0 / 2 0 2 3 9 : 3 5 A M PL O T D A T E : 29 RA I N G A R D E N 10 / 2 8 / 2 0 2 2 2N D R E S U B M I T T A L - N O C L U B H O U S E MAY 30, 2023 RI D G E W O O D H I L L S F I F T H F I L I N G - M A FI N A L U T I L I T Y P L A N S FO R T C O L L I N S , CO L O R A D O 2929 05 / 3 0 / 2 0 2 3 3R D R E S U B M I T T A L 12 / 2 0 / 2 0 2 3 RE S U B M I T T A L NOTES: 1.CONTRACTOR SHALL INSTALL BIORETENTION BASINS ACCORDING TO THE APPROVED PLANS AND/OR CONSTRUCTION SPECIFICATIONS. 2.PRE-CONSTRUCTION 2.1.CONTRACTOR SHALL AVOID COMPACTION OF THE BIORETENTION BASIN AREA TO PRESERVE EXISTING INFILTRATION RATES. 2.2.CONTRACTOR SHALL CALL FOR CITY INSPECTIONS AT THE INTERVALS STIPULATED IN THE "DURING CONSTRUCTION INSPECTION CHECKLISTS". 3.DURING CONSTRUCTION: 3.1.CONTRACTOR SHALL PROVIDE CONSTRUCTION OBSERVATION DURING CONSTRUCTION OF THE BIORETENTION BASIN TO ENSURE COMPLIANCE WITH THE APPROVED PLANS AND DESIGN SPECIFICATIONS. 3.2.LOOSE MATERIALS SHALL NOT BE STORED ON THE BIORETENTION AREA. 3.3.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS AND DIRT FROM ANY SOURCE FROM ENTERING THE BIORETENTION SYSTEM. 4.GEOTEXTILE LINERS: 4.1.WHERE USED, GEOTEXTILE LINERS (PERMEABLE OR IMPERMEABLE AS PER PLAN) SHALL BE INSTALLED ALONG PERIMETER OF CROSS-SECTION OF THE BIORETENTION CELL. 4.2.WHERE USED, GEOTEXTILE LINERS SHALL BE PLACED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDATIONS. ALL SEAMS AND OPENINGS IN THE LINER SHALL BE SEALED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 4.3.WHERE USED, IMPERMEABLE GEOMEMBRANE SHEET / LINER SHALL BE 40 MIL THICK, HIGH-DENSITY POLYETHYLENE DESIGNED SPECIFICALLY FOR FLEXIBLE GEOMEMBRANE APPLICATIONS. ADJACENT STRIPS OF IMPERMEABLE LINER SHALL OVERLAP A MINIMUM OF 18", OR PER MANUFACTURER'S SPECIFICATION. 4.4.WHERE USED, CONTRACTOR TO PLACE LINER IN A WAY THAT ENSURES ENOUGH SLACK IN THE LINER TO ALLOW FOR BACKFILL AND SETTLING WITHOUT TEARING THE LINER. 5.AGGREGATES AND BSM: 5.1.ALL AGGREGATES SHALL BE ANGULAR, CRUSHED, WASHED ROCK, CLEAN OF DEBRIS AND WITH NO MORE THAN 1% FINES. 5.2.RESERVOIR AGGREGATE SHALL BE GRADATION ASTM #57 OR #67. 5.3.DIAPHRAGM AGGREGATE SHALL BE "PEA GRAVEL", WITH GRADATION ASTM #8, #89 OR #9. 5.4.THE BIORETENTION SOIL SHALL MEET THE CITY BIORETENTION SAND MEDIA ("BSM") SPECIFICATION FOUND AT:https://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulations/ 6. UNDERDRAIN: 6.1.UNDERDRAIN PIPE TO BE PERFORATED OR SLOTTED. PERFORATIONS OR SLOTS TO BE SMALLER THAN SURROUNDING AGGREGATE TO ENSURE AGGREGATE DOES NOT FALL INTO OR CLOG THE OPENINGS. 6.2.DO NOT WRAP UNDERDRAIN WITH GEOTEXTILE OR SOCK. 6.3.UNDERDRAIN PIPE MUST OUTFALL BY GRAVITY AND MUST TIE INTO A STORMWATER PIPE, INLET OR SYSTEM AND THE LOCATION MUST BE APPROVED BY THE CITY. THE UNDERDRAIN TIE-IN SHALL MEET ALL REQUIRED PIPE SIZE, TYPES, AND COVER REQUIREMENTS THAT MAY APPLY TO PIPING THAT EXTENDS BEYOND THE LIMITS OF THE BIORETENTION CELL AND ENCROACHES INTO PUBLIC RIGHT-OF-WAY OR OTHER PROPERTY. 7.OVERFLOW INLET: 7.1.A 100-YEAR OVERFLOW SPILLWAY OR INLET MUST BE PROVIDED. 7.2.ALL OVERFLOW INLETS SHALL BE CAPPED WITH A DOME-SHAPED GRATE, OR PER PLAN. 7.3. IN ALL CASES, AN EMERGENCY OVERFLOW ROUTE SHALL BE PROVIDED AND THE LOCATION SHALL BE IDENTIFIED ON THE PLANS (THIS MAY BE COINCIDENT WITH THE 100 YEAR OVERFLOW SPILLWAY). 8.CLEANOUTS: 8.1.PROVIDE CLEANOUTS (AS PER PLAN) TO ALLOW INSPECTION (BY CAMERA) OF THE UNDERDRAIN SYSTEM DURING AND AFTER CONSTRUCTION. 8.2.CLEANOUTS SHALL BE PROVIDED AT EACH BEND GREATER THAN OR EQUAL TO 90° AND EVERY 100' ALONG A STRAIGHT RUN. CLEANOUT SHALL BE INSTALLED PER THE APPROVED PLANS. 8.3.CLEANOUTS SHALL BE A SOLID WALL PVC STRUCTURE FOR ALL VERTICAL SECTIONS WITH FITTINGS TO CONNECT TO DISTRIBUTION AND UNDERDRAIN PIPING MATERIALS, AS REQUIRED. 9.FOREBAY: 9.1.THE FOREBAY SHALL BE EASILY ACCESSIBLE WITH A HARD SURFACED BOTTOM FOR MAINTENANCE PURPOSES. 10.LANDSCAPE MATERIALS 10.1.CONTRACTOR SHALL NOT PLACE WEED BARRIER ANYWHERE WITHIN THE BIORETENTION BASIN. IF MULCH IS PLACED IN THE BIORETENTION BASIN, IT MUST BE NON-FLOATABLE. 10.2.IF MULCH OR COBBLES ARE PLACED IN THE BIORETENTION BASIN, THE MAXIMUM ALLOWABLE WATER DEPTH OF 12" AND REQUIRED BASIN VOLUME MUST BE MEASURED FROM THE TOP SURFACE OF THE MULCH OR COBBLE. 10.3.ROLLED TURF OR SOD IS NOT AN ALLOWABLE LANDSCAPE MATERIAL FOR BIORETENTION BASINS. LOW WATER CONSUMPTION LANDSCAPE PLANTINGS ARE PREFERRED FOR BIORETENTION BASINS. 10.4.LANDSCAPE PLANTINGS SHALL NOT BE PLACED TO IMPEDE DRAINAGE INTO OR OUT OF THE BIORETENTION BASIN. 10.5.TEMPORARY IRRIGATION MAY BE INSTALLED TO ESTABLISH LANDSCAPING OR SEED IN THE BIORETENTION BASIN. CITY OF FORT COLLINS BIORETENTION SAND MEDIA SPECIFICATION PART 1 - GENERAL A.Bioretention Sand Media (BSM) shall be uniformly mixed, uncompacted, free of stones, stumps, roots, or other similar objects larger than two inches. No other materials or substances shall be mixed or dumped within the bioretention area that may be harmful to plant growth or prove a hindrance to the facility's function and maintenance. B.BSM shall be free of plant or seed material of non-native, invasive species, or weeds. C.Fully mixed BSM shall be tested prior to installation and meet the following criteria: 1.P-Index of less than 30 2. pH of 5.5-6.5. Should pH fall outside of the acceptable range, it may be modified with lime (to raise) or iron sulfate plus sulfur (to lower). The lime or iron sulfate must be mixed uniformly into the BSM prior to use in the bioretention facility. 3. Cation Exchange Capacity (CEC) greater than 10 4. Phosphorous (Phosphate, P2O5) not to exceed 69 ppm 5. BSM that fails to meet the minimum requirements shall be replaced at the Contractor's expense. D.BSM shall be delivered fully mixed in a drum mixer. Onsite mixing of piles will not be allowed. Mixing of the BSM to a homogeneous consistency shall be done to the satisfaction of the Owner. PART 2 - SOIL MATERIALS A.Sand 1.BSM shall consist of 60% sand by volume meeting ASTM C-33. B.Shredded Cedar Mulch 1.BSM shall consist of 5% shredded cedar mulch by volume. 2.Shredded mulch shall be loosely packed, approximate bulk density of 50-100 lbs/CY. C.Topsoil 1.BSM shall consist of 30% topsoil by volume. 2.Topsoil shall be classified as sandy loam, loamy sand, or loam per USDA textural triangle with less than 5% clay material. 3.Onsite, native material shall not be used as topsoil. 4.Textural analysis shall be performed on topsoil, preferably at its source, prior to including topsoil in the mix. Topsoil shall be free of subsoil, debris, weeds, foreign matter, and any other material deleterious to plant health. 5.Topsoil shall have a pH range of 5.5 to 7.5 and moisture content between 25-55%. 6.Contractor shall certify that topsoil meets these specifications. D.Leaf Compost 1.BSM shall consist of 5% leaf compost by volume. 2.Leaf compost shall consist of Class 1 organic leaf compost consisting of aged leaf mulch resulting from biological degradation and transformation of plant-derived materials under controlled conditions designed to promote aerobic decomposition. 3.The material shall be well composted, free of viable weed seeds and contain material of a generally humus nature capable of sustaining growth of vegetation, with no materials toxic to plant growth. 4.Compost shall be provided by a local US Composting Council Seal of Testing Assurance (STA) member. A copy of the provider's most recent independent STA test report shall be submitted to and approved by the Owner prior to delivery of BSM to the project site. 5.Compost material shall also meet the following criteria: a.100 percent of the material shall pass through a 1/2 inch screen b.PH of the material shall be between 6.0 and 8.4 c.Moisture content shall be between 35 and 50 percent d.Maturity greater than 80 percent (maturity indicator expressed as percentage of germination/vigor, 80+/80+) e.Maturity indicator expressed as Carbon to Nitrogen ration < 12 f.Maturity indicator expressed as AmmoniaN/NitrateN Ratio <4 g.Minimum organic matter shall be 40 percent dry weight basis h.Soluble salt content shall be no greater than 5500 parts per million or 0-5mmhos/cm i.Phosphorus content shall be no greater than 325 parts per million j.Heavy metals (trace) shall not exceed 0.5 parts per million k.Chemical contaminants: meet or exceed US EPA Class A standard, 40 CFR 503.13, Tables 1 & 3 levels l.Pathogens: meet or exceed US EPA Class A standard, 40 CFR 503.32(a) levels PART 3 - EXECUTION A.General 1.Refer to project specifications for excavation requirements. B.Placement Method 1.BSM material shall be spread evenly in horizontal layers. 2.Thickness of loose material in each layer shall not exceed 9-inches. 3.Compaction of BSM material is not required.