Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTAPESTRY - FDP240016 - SUBMITTAL DOCUMENTS - ROUND 1 - Variance Request Water/Wastewater
Variance Application
City of Fort Collins Water Utilities Engineering
Section A: Engineer/Owner Information
Engineer Name Cody Pape Phone (970) 568-5412
Street Address 301 North Howes Street, Suite 100
City Fort Collins State Colorado Zip 80521
Owner Name Kristin Candella Phone (970) 286-5889
Street Address 4001 S. Taft Hill Road
City Fort Collins State Colorado Zip 80526
ProposedSection B:
Project Name Tapestry
Project/Application Number from Development Review (i.e. FDP123456) PDP240001
Legal description and/or address of property Located in the Northeast Quarter of Section 12, Township 7
North, Range 69 West, of the 6th P.M., Fort Collins, Larimer County, Colorado
Description of Project Seven muti-family buildings with associated parking lots, a community park,
new roads (Logan Ave and 4th St), required utilities and drainage infrastructure.
Existing Use (check one): 0 residential 0 non-residential Q mixed-use C7 vacant ground
Proposed Use (check one): (j) residential r,non-residential C)mixed-use C'i other
If non-residential or mixed use, describe in detail
Section C: Variance Information
State the requirement from which variance is sought:
FC Utilities WW DCM Section 4.06 E
What hardship prevents this site from meeting the requirement?
The sewer connection proposed at the southeast end of the site is the only tie-in possible. A sanitary
sewer tie-in location east of the site in Buckingham Street was evaluated but did not have capacity or
depth. Another sanitary sewer tie-in location was evaluated at the intersection of 3rd Street and
Logan Ave but did also not have sufficient capacity and depth to serve the site.
Attach separate sheet if necessary
What alternative is proposed for the site?
A 245 foot long concrete encasement is proposed for the section of sanitary sewer that does not
meet the minimum depth of 4' specification set out in Section 4.06 E. The concrete encasement shall
be constructed per Fort Collins sanitary sewer concrete encasement detail WW-6. '
Attach separate sheet if necessary
page 2
The owner agrees to comply with the provisions of the zoning ordinance, building code and all other
applicable sections of the City Code, Land Use Code, City Plan and all other laws and ordinances
affecting the construction and occupancy of the proposed building that are not directly approved by
this variance. (� p
Signature of owner: h v\-- ` , C, G Date: z 02 {
Date complete application submitted:
Date of approval/denial: Variance: 0 approved ® denied
Staff justification/notes/conditions:
• Approved by:
Entered in UtilityFile Database? ©yes ®no
If you have questions or need assistance fi [ling out forms, contact Fort Collins Utilities at: