HomeMy WebLinkAboutTAPESTRY - FDP240016 - SUBMITTAL DOCUMENTS - ROUND 1 - Supporting Documentation (3)VAULT
CABLE
ELEC
ELEC
D
CS
W
CS
CS
CS
HYD
C S
W
W
W W W W W W W W W W W W W W W W W W
E
E
E FO FO
G G G G G G G G G G G G G G G G G G G GWWWWWWWWWWWWWWWWWWWW
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
E
E
E
E
E
E
E
E
E
E
E
X
X
X
X X
X X
W
W W W W W W W W W W W W W W W W W W
E
E
E FO FO
G G G G G G G G G G G G G G G G G G G GWWWWWWWWWWWWWWWWWWWW
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
E
E
E
E
E
E
E
E
E
E
E
X
X
X
X X
X X
HYD
X
X
X
X
X
X
X
X
X
X
8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W
8" W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
8"
W
E
E E
E E E
G
G
G
G
G
G
G
G
G
G
G
G
G
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G G G G G G G G
G G G G G G G G G
E
E
E
E
E
G
G G G G
G
G
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E E E E E E
EEEEEEEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
FOFOFOFOFOFOFOFOFOFO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO FO FO FO FO FO FO FO FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E E E E E E E
UD
UD
E E E E E
E E E E
UD
UD
UD
UD
DUCTILE IRON
NYLOPLAST
DUCTILE IRON
NYLOPLAST
62'-0" R.O.W.
26
'
-
0
"
UT
I
L
I
T
Y
,
DR
A
I
N
A
G
E
AN
D
EA
E
4T
H
S
T
R
E
E
T
3R
D
S
T
R
E
E
T
BUCKINGHAM STREET
LOGAN STREET
3
14
2
12
BUCKINGHAM
NEIGHBORHOOD
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /
DN
DN
DNDN
DN
DN
DNDN
DN DN
DN
DN
DNDN
/ /
/
/
/
/
/
/
/ / /
/
/
/
/
/
/ / / / /
/
/
/
/ / /
/
/
/
/
/
/ /
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/ /
/
/
/
/
/
/
/ / /
/
/
/
/
/
/ / / /
/
/
/
/
/ / / /
/
/
/
/
63
'
-
0
"
R
.
O
.
W
.
60'-0" R.O.W.
24'-0"
UTILITY,
DRAINAGE
AND
EAE
26'-0"
UTILITY,
DRAINAGE
AND
EAE
26
'
-
0
"
UT
I
L
I
T
Y
,
DR
A
I
N
A
G
E
AN
D
EA
E
10
COLORADO
IRON AND
METAL
BUILDING 6
TYPE B
3-STORY CRAFTSMAN
BUILDING 7
TYPE A
3-STORY FARMHOUSE
2 322
8
14
7
12
6
2
12
BUILDING 5
TYPE A
3-STORY FARMHOUSE
BUILDING 4
TYPE A
3-STORY FARMHOUSE
14
14
13
5
4
4 2
12
BUILDING 2
TYPE B
3-STORY CRAFTSMAN
BUILDING 1
TYPE A
3-STORY FARMHOUSE
BUILDING 3
TYPE B
3-STORY CRAFTSMAN
1114
9'-11"
68
'
-
0
"
R
.
O
.
W
.
NEW BELGIUM BREWERY
GARAGE 1
GA
R
A
G
E
2
GARAGE 3
143'-9"
VAN GARAGE
(ELECTRIC VEHICLE
CHARGER INSTALLED
10
TRACT A
OUTLOT Z
DETENTION
LOT 1
TRACT B
EXISTING 6' HEIGHT
SOLID METAL FENCE
EXISTING 6' HEIGHT
SOLID METAL FENCE
2
4
3
13
3
2
4
3
1
1
14
12
3
SITE PLAN NOTES:
1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS
MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE
PLANS.
2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE
STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL
EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM
ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH
SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE
BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS
SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES.
5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN
IS SHOWN WITH THESE PLANS.
6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF
THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF
CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY
SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A
SPECIFIC VARIANCE IS GRANTED BY THE CITY.
8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN
APPROVED FIRE EXTINGUISHING SYSTEM.
9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED.
10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT
ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE
PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO
MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE.
11.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC
CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNER
OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET
SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS.
12.DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN
ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL
ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER.
13.THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH
UNIT/APARTMENT BUILDING.
14.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE
COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING
THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING,
SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF
LOCATED IN BACK YARDS), ODOR-CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT
A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS.
15.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S
EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE
FIRST CERTIFICATE OF OCCUPANCY.
16.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR
TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL,
APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE
PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION
THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE
CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY.
17.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND
POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE
DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY FINDING. ALL BUILDINGS SHALL HAVE
ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS
PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM
OF EIGHT INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD
AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS
SHALL BE USED TO IDENTIFY THE STRUCTURE.
18.ALL GARAGES IN BUILDINGS 1-7 SHALL BE EQUIPPED WITH 220 ELECTRIC.
FLOODPLAIN AND FLOODWAY NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATORY 500-YEAR FLOODPLAIN AND MODERATE
RISK.
2.ALL DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE FLOODPLAIN REGULATIONS OF CHAPTER 10
OF CITY OF FORT COLLINS MUNICIPAL CODE.
3.RESIDENTIAL STRUCTURES ARE ALLOWED IN THE 500 YEAR HIGH RISK FLOOD FRINGE PROVIDED THEY MEET ALL
ELEVATION REQUIREMENTS OF CHAPTER 10 OF CITY MUNICIPAL CODE
4.ESSENTIAL SERVICES FACILITIES AND AT RISK POPULATION FACILITIES ARE PROHIBITED IN THE POUDRE RIVER 500
YEAR FLOODPLAIN. CRITICAL FACILITIES SHALL INCLUDE ESSENTIAL SERVICES FACILITIES, HAZARDOUS MATERIALS
FACILITIES, AT-RISK POPULATION FACILITIES AND GOVERNMENT SERVICES FACILITIES
SITE LEGEND:
RIGHT-OF-WAY / PROPERTY LINE
EASEMENT LINE
9' SETBACK
ROLL TOP EDGER
6" THICK CONCRETE PAVEMENT
COLOR: STANDARD
4" THICK CONCRETE PAVEMENT
COLOR: STANDARD
CRUSHER FINES PAVEMENT
ENGINEERED WOOD FIBER (EWF)
PICNIC TABLE
SHELTER
BENCH
BIKE RACK
LIGHT POLE (REFER TO PHOTOMETRIC
PLAN)
STREET LIGHT
TRASH / RECYCLING ENCLOSURE
DOG WASTE BAG STATION
PLANTING AREA
FIRE RISER ROOM
PA
FR
0 20'40'40'80'N O R T H
LS100
OVERALL SITE PLAN
Sheet
Sheet Name
Checked By:
Drawn By:
Date:
CR
SL
11.13.2024
TA
P
E
S
T
R
Y
FINAL
DEVELOPMENT
PLAN241105-Tapestry EV Parking Diagram
20%+ of the project is affordable housing units, as defined by the
Land Use Code, surpassing the Code requirement of 10%.
Therefore, the project is subject to the Affordable classification of
required EV chargers under the City's EV charger code.
Required, per code:
- EVSE = 1
- EV – Ready = 29
- EV – Capable = 39
Provided:
- EVSE = 1 (ADA Van garage stall)
- EV – Ready = 91
- EV – Capable = 0
14
13
14
1412
12
12