Loading...
HomeMy WebLinkAboutTAPESTRY - FDP240016 - SUBMITTAL DOCUMENTS - ROUND 1 - Supporting Documentation (3)VAULT CABLE ELEC ELEC D CS W CS CS CS HYD C S W W W W W W W W W W W W W W W W W W W W E E E FO FO G G G G G G G G G G G G G G G G G G G GWWWWWWWWWWWWWWWWWWWW G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W E E E E E E E E E E E X X X X X X X W W W W W W W W W W W W W W W W W W W E E E FO FO G G G G G G G G G G G G G G G G G G G GWWWWWWWWWWWWWWWWWWWW G G G G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W E E E E E E E E E E E X X X X X X X HYD X X X X X X X X X X 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W E E E E E E G G G G G G G G G G G G G E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E EEEEEEEEEE E E E E E E E E E E E E E E E FOFOFOFOFOFOFOFOFOFO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E UD UD E E E E E E E E E UD UD UD UD DUCTILE IRON NYLOPLAST DUCTILE IRON NYLOPLAST 62'-0" R.O.W. 26 ' - 0 " UT I L I T Y , DR A I N A G E AN D EA E 4T H S T R E E T 3R D S T R E E T BUCKINGHAM STREET LOGAN STREET 3 14 2 12 BUCKINGHAM NEIGHBORHOOD / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / DN DN DNDN DN DN DNDN DN DN DN DN DNDN / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 63 ' - 0 " R . O . W . 60'-0" R.O.W. 24'-0" UTILITY, DRAINAGE AND EAE 26'-0" UTILITY, DRAINAGE AND EAE 26 ' - 0 " UT I L I T Y , DR A I N A G E AN D EA E 10 COLORADO IRON AND METAL BUILDING 6 TYPE B 3-STORY CRAFTSMAN BUILDING 7 TYPE A 3-STORY FARMHOUSE 2 322 8 14 7 12 6 2 12 BUILDING 5 TYPE A 3-STORY FARMHOUSE BUILDING 4 TYPE A 3-STORY FARMHOUSE 14 14 13 5 4 4 2 12 BUILDING 2 TYPE B 3-STORY CRAFTSMAN BUILDING 1 TYPE A 3-STORY FARMHOUSE BUILDING 3 TYPE B 3-STORY CRAFTSMAN 1114 9'-11" 68 ' - 0 " R . O . W . NEW BELGIUM BREWERY GARAGE 1 GA R A G E 2 GARAGE 3 143'-9" VAN GARAGE (ELECTRIC VEHICLE CHARGER INSTALLED 10 TRACT A OUTLOT Z DETENTION LOT 1 TRACT B EXISTING 6' HEIGHT SOLID METAL FENCE EXISTING 6' HEIGHT SOLID METAL FENCE 2 4 3 13 3 2 4 3 1 1 14 12 3 SITE PLAN NOTES: 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12.DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 13.THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH UNIT/APARTMENT BUILDING. 14.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODOR-CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 15.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 16.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 17.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF EIGHT INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. 18.ALL GARAGES IN BUILDINGS 1-7 SHALL BE EQUIPPED WITH 220 ELECTRIC. FLOODPLAIN AND FLOODWAY NOTES: 1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATORY 500-YEAR FLOODPLAIN AND MODERATE RISK. 2.ALL DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE FLOODPLAIN REGULATIONS OF CHAPTER 10 OF CITY OF FORT COLLINS MUNICIPAL CODE. 3.RESIDENTIAL STRUCTURES ARE ALLOWED IN THE 500 YEAR HIGH RISK FLOOD FRINGE PROVIDED THEY MEET ALL ELEVATION REQUIREMENTS OF CHAPTER 10 OF CITY MUNICIPAL CODE 4.ESSENTIAL SERVICES FACILITIES AND AT RISK POPULATION FACILITIES ARE PROHIBITED IN THE POUDRE RIVER 500 YEAR FLOODPLAIN. CRITICAL FACILITIES SHALL INCLUDE ESSENTIAL SERVICES FACILITIES, HAZARDOUS MATERIALS FACILITIES, AT-RISK POPULATION FACILITIES AND GOVERNMENT SERVICES FACILITIES SITE LEGEND: RIGHT-OF-WAY / PROPERTY LINE EASEMENT LINE 9' SETBACK ROLL TOP EDGER 6" THICK CONCRETE PAVEMENT COLOR: STANDARD 4" THICK CONCRETE PAVEMENT COLOR: STANDARD CRUSHER FINES PAVEMENT ENGINEERED WOOD FIBER (EWF) PICNIC TABLE SHELTER BENCH BIKE RACK LIGHT POLE (REFER TO PHOTOMETRIC PLAN) STREET LIGHT TRASH / RECYCLING ENCLOSURE DOG WASTE BAG STATION PLANTING AREA FIRE RISER ROOM PA FR 0 20'40'40'80'N O R T H LS100 OVERALL SITE PLAN Sheet Sheet Name Checked By: Drawn By: Date: CR SL 11.13.2024 TA P E S T R Y FINAL DEVELOPMENT PLAN241105-Tapestry EV Parking Diagram 20%+ of the project is affordable housing units, as defined by the Land Use Code, surpassing the Code requirement of 10%. Therefore, the project is subject to the Affordable classification of required EV chargers under the City's EV charger code. Required, per code: - EVSE = 1 - EV – Ready = 29 - EV – Capable = 39 Provided: - EVSE = 1 (ADA Van garage stall) - EV – Ready = 91 - EV – Capable = 0 14 13 14 1412 12 12