HomeMy WebLinkAboutVON VIHL HEIGHTS THIRD SUBDIVISION - BDR240007 - SUBMITTAL DOCUMENTS - ROUND 2 - Variance Request (2)A CCESS V ARIANCE R EQUEST
C ARLSON U TILITY P LAN
F ORT C OLLINS ,CO
19 OLD TOWN SQUARE #238 | FORT COLLINS, CO 80524 | 970-530-4044 | www.unitedcivil.com
July 22, 2024
BRAD BUCKMAN
700 WOOD STREET
FORT COLLINS,CO 80522
RE: ACCESS ALTERNATIVE COMPLIANCE AND VARIANCE REQUESTS
CARLSON UTILITY PLAN –3036 WEST PROSPECT ROAD
PROJECT NUMBER:U24001
Brad,
This letter is being submitted on behalf of the owner of the Carlson site development. The project is currently in the
Preliminary Development Plan process and two (2) separate variances are being requested to modify portions of the Larimer
County Urban Area Street Standards. The second of the two is as follows:
VARIANCE REQUEST –LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS)
DESIGN CRITERIA OF VARIANCE BEING REQUESTED
Section 9.1.1 (C) within the Larimer County Urban Area Street Standards Manual which states:
The specific separation distances between accesses shall be as shown in Table 7-3 or Table 7-4. Greater separation
may be required to eliminate conflicts or overlaps of center left turn lanes as determined by TIS. For this project,
driveway separation found in LCUASS Table 7.3 for 2 lane arterials is 460-600 feet minimum.
HARDSHIP REGARDING REQUIREMENT
The site is located at 3036 West Prospect Road and exists as Lot 11 within the Von Vihl Heights Subdivision, County of Larimer,
State of Colorado, and is surrounded by existing developed residential properties to the north (1504 S Overland Trail) and
east (3030 West Prospect Road). The project site is also bordered by West Prospect Road and South Overland Trail to the
south and west respectively. The developed project proposes to subdivide the lot into two separate lots with the existing
residence, driveways/access, and utilities being encompassed in the southern lot or Lot 2 leaving the northern lot, Lot 1, as a
vacant parcel which will require access from Overland Trail and utility service lines.
In its existing condition the site maintains an asphalt driveway providing two access points to the property along West
Prospect Road. The two site access points in their current condition exist approximately thirty-one (31) feet apart from one
another. Additionally, the south facing property line consists of approximately one hundred and eleven (111) feet in length.
West Prospect Road is considered a 2-lane arterial road and therefore is required to uphold a minimum distance between
driveway edges and a corner clearance between driveways and street intersections of 460’-660’ per the LCUASS street design
and technical criteria.
Please refer to appendix A for the LCUASS table implementing said constraints. Seeing as the entirety of the property length
running parallel to Prospect Road is only one hundred and eleven (111) feet, which makes up only a fraction of the
requirements, and the entire block itself is shorter than the required length, there is no possible driveway
placement/configuration that satisfies the design requirements. Yielding to these constraints is therefore deemed to be
unattainable.
PROPOSED ALTERNATE DESIGN
The existing and proposed site design provides direct access to the existing residence and Lot 2 from West Prospect Road
from existing driveways. As such, the development team proposes to maintain the existing conditions and uphold the current
A CCESS V ARIANCE R EQUEST
C ARLSON U TILITY P LAN
F ORT C OLLINS ,CO
19 OLD TOWN SQUARE #238 | FORT COLLINS, CO 80524 | 970-530-4044 | www.unitedcivil.com
access design, bypassing costly and unnecessary removal and construction of infrastructure and providing residential access
to the site. The following sections of this variance request serve to document the negligible impacts this alternate design will
have.
Seeing as access to the site must be provided, and the current site design includes previously approved access points,
upholding existing conditions accomplishes the goal of providing site access without expanding project scope, site and road
disturbance, or having negative consequences on the health safety and welfare of the public. In summary, by maintaining the
existing site conditions:
1.Disturbance within the existing roads and site are minimized
2.Direct access to the residence is provided via an existing driveway and approaches
Based on the information provided for this access variance request, it is the design teams opinion that the proposed design
will have no negative impacts on the health, safety and welfare of the public and will have no negative impacts on City
infrastructure, or neighboring properties.
On behalf of the owner of the Carlson site and the design team, we thank you for your consideration of this request. If you
should have any questions or comments regarding this request, please feel free to contact us at your convenience.
Sincerely,
United Civil Design Group, LLC
Brady Kirkbride, EI
Design Engineer
Nate Stroud, PE, LSIT
Project Manager
APPENDIX A – Referenced Materials
A PPENDIX A
R EFERENCED M ATERIALS
Chapter 9 – ACCESS REQUIREMENTS AND DESIGN CRITERIA
Section 9.1 General
Larimer County Urban Area Street Standards – Repealed and Reenacted August 1, 2021 Page 9-1
Adopted by Larimer County, City of Loveland, City of Fort Collins
CHAPTER 9 – ACCESS REQUIREMENTS AND DESIGN CRITERIA
9.1 GENERAL
Access may occur as one of two types: (1) access for land use (driveways) and (2) public streets
(street intersections).
9.1.1 Designing Placement of Accesses
A. Direct Access Restricted
Direct access to individual lots from Arterials is restricted. For City of Loveland
(GMA and city limits) direct access to is restricted from Arterials and Collectors.
B. Avoiding Conflicts in Center Left Turn Lane
When establishing the placement of offset accesses (either driveways or
intersections), ensure that traffic making left-hand turns into the accesses does not
conflict or compete for the simultaneous use of a center left turn lane.
C. Separation Distances
The specific separation distances between accesses shall be as shown in Table 7-3 or
Table 7-4. Greater separation may be required to eliminate conflicts or overlaps of
center left turn lanes as determined by TIS.
D. Access Control Plan
For a street controlled by an adopted Access Control Plan, the proposed access shall
conform with the applicable Access Control Plan.
9.1.2 Review and Approval
A. Review Procedure
1. Advice Available. To determine the extent of technical justification required for
all access requests, consult with the Local Entity Engineering staff. It is
recommended that this advice be sought prior to submitting any application.
2. Access Permits. All access permits shall be reviewed and approved through the
Local Entity, in Fort Collins (GMA and city limits) and in Loveland (GMA only).
Loveland (GMA and city limits) does not issue or require a separate access
permit. The requirements of this chapter are covered in the City of Loveland's
design review of the right-of-way permit.
3. Permit Required. A permit must be requested by the Developer and approved by
the Local Entity prior to the construction or reconstruction of any access. See
Chapter 6, Permits.
4. CDOT Approval for State Highway Access. The Colorado Department of
Transportation shall review and approve all State Highway access.
B. Approval
Access is granted through Local Entity approval of the final plat, final construction
plans, or final site plan. The number and location of access points shall conform to
Table 7-3
Fort Collins (GMA and City Limits) Street Standards - Technical Design Criteria
1~2 lane
Design Element Arterial Collector Local
Comm/Industrial | Residential
Alley
4 or 6 lane Major Minor
Overall Design Parameters
Design Speed /
Posted Speed
50/40-45 (6)
50/35-45 (4)
30/25 connector
25/2550/30-45 40/30-35 40/25-30 30/25 15
Stopping Sight Distance 425 425 305 305 200' 200’ 80
Horizontal Alignment
Minimum centerline radius 1075’ 1075’ 600’ 600’ 275’275' connector
165’
50’
(with no super-elevation)
Maximum super-elevation 0.04 ft/ft 0.04 ft/ft 0.04 ft/ft NA NA NA NA
200’ 200’150’ 100’ 100’ 100’20’Minimum tangent between curves or
at intersections 1
Vertical Alignment
Maximum Centerline Grade 5% 5% 6% 8% 8% 8% 8%
Minimum Gutter Flowline Grade 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Minimum
K-values for Vertical
Curves
Crest 84 84 44 44 19 19 connector
12 all others
3
Sag 96 96 64 64 37 37 connector
26 all others
10
Intersection Design
Minimum sight distance at driveways
and intersections
1030’ 1030’660’ 660’310’260’210’
Without
Raised
Median
With
Raised
Median
Without
Raised
Median
With
Raised
Median
Access Management
Signalized 2640’5 Min. 2640'5 Min.Distance
between
intersections2
NA NA NA NA NA
460’-
660’5
1320'6
Min.
460’-
660’5
660'6
Min.
460’-
660’5
1320'6
Min.
460’-
660’5
660’6
Min.
330’ Min. 250’ Min. 200’ Min. 200’ Min.Unsignalized NA
Distance between high volume
driveways and intersections2
460’-
660’5
1320'6
Min.
460’-
660’5
460’-
660’5
1320'6
Min.
330’
Min.
200’ Min. 175’ Min. 175’ Min. 150’ Min. NA
660'6
Min.
Distance between driveway edges 460’-
660’5
660’6
Min.
460’-
660’6
660'6
Min.
460’-
660’5
660’6
Min.
330’
Min.
75’ Min. 30’ Min. 30’ Min. 12’ Min. No limit
Corner clearance between 460’ - 660’5 460’ - 660’5 175’ Min. 100’ Min. 175’ Min. 50’ Min. 40’ Min.
driveways/alleys & street intersections2
Driveway approach street config.3 Curb cut4 Curb cut4 Curb cut4 Curb cut4 Curb cut4Radial curb return Radial curb return
1 Intersection tangents are measured from flowline of the intersected street at intersections. Note: Two curves in the same direction must be separated by a tangent at least two times the minimum tangent
lengths shown in Table 7-3 and Table 7-4.
2 These distances are measured as shown in Figure 9-1.
3 Table indicates residential driveways. All commercial driveways shall be constructed with radial curb returns (see Section 9.3.2).
4 Radial curb returns are also allowed where traffic volumes meet the requirements for a High Volume Driveway.
5 For a distance less than 460' an administrative variance must be approved by the Local Entity Engineer; for a distance greater than 660’ a modification in accordance with the Land Use Code will be required.
6 Minimum spacing for full movement and/or potentially signalized intersections
Larimer County Urban Area Street Standards - Repealed and Reenacted August 1, 2021
Adopted by Larimer County, City of Loveland, City of Fort Collins
Page 7-8