Loading...
HomeMy WebLinkAboutVON VIHL HEIGHTS THIRD SUBDIVISION - BDR240007 - SUBMITTAL DOCUMENTS - ROUND 2 - Utility PlansW P R O S P E C T R D SOUTH OVERLAND TRAIL 8" CLAY PIPE 60" STEEL WATER MAIN (FORT COLLINS) 12" CAST IRON WATER MAIN (FORT COLLINS) FUTURE 4" SANITARY SERVICE @ 2.0% MINIMUM SLOPE LO T 1 2 , VO N V I H L H E I G H T S SE C O N D S U B D I V I S I O N RE C E P T I O N N O . 7 7 8 7 3 4 ( 1 9 6 0 ) 30 ' R I G H T O F W A Y P E R P L A T LOT 10, VON VIHL HEIGHTS SUBDIVISION RECEPTION NO. 765654 (1959) 30' RIGHT OF WAY PER PLAT LO T 1 1 , VO N V I H L H E I G H T S SE C O N D S U B D I V I S I O N RE C E P T I O N N O . 7 7 8 7 3 4 ( 1 9 6 0 ) 15' UTILITY EASEMENT DEDICATED BY PLAT 5' UTILITY EASEMENT RECEPTION NO. 765654 (1959) 15' REAR SETBACK 30' FRONT SETBACK (SEE NOTE 12) 5' S I D E S E T B A C K 5' S I D E S E T B A C K 17' PUBLIC AND PRIVATE UTILITY EASEMENT DEDICATED BY PLAT 15' UTILITY EASEMENT DEDICATED BY PLAT 13.5' RIGHT OF WAY DEDICATED BY PLAT LOT2 10,769 s.f. LOT 1 11,697 s.f. 15 ' R E A R S E T B A C K 30 ' F R O N T S E T B A C K FUTURE CLEANOUT FUTURE SANITARY SERVICE AND CLEANOUT EXTENDED INTO LOT EXISTING GROUND: 5125.3' APPROX. 4" SERVICE INVERT: 5118.7' EXISTING BUILDING EXISTING OVERHEAD ELECTRIC EXISTING STORM LINE EXISTING SIDEWALK EXISTING ASPHALT DRIVE EX I S T I N G S I D E W A L K EXISTING DRIVEWAY CUT EXISTING DRIVEWAY CUT EXISTING GAS LINE EX I S T I N G A S P H A L T D R I V E EXISTING DRIVEWAY CUT EXISTING FENCE 5' SIDE SETBACK FUTURE ELECTRIC SERVICE FUTURE GAS SERVICE EX. SSMH RIM = 5125.9 INV 4" (NW) = 5117.5 INV 6" (N) = 5117.2 INV 4" (SW) = 5115.8 INV 8" (E) = 5115.3 15' UTILITY EASEMENT DEDICATED BY PLAT EXISTING 8" CAST IRON WATER MAIN (FORT COLLINS) FUTURE WATER METER AND CURB STOP FUTURE WATER SERVICE FUTURE WATER SERVICE EXTENDED INTO LOT GAS SERVICE EXTENDED INTO LOT FUTURE ELECTRIC SERVICE EXTENDED INTO LOT 5' DRAINAGE EASEMENT DEDICATED BY PLAT 5' DRAINAGE EASEMENT DEDICATED BY PLAT 5' DRAINAGE EASEMENT DEDICATED BY PLAT PROPOSED ACCESS TO LOT 1 TO BE CONSTRUCTED OFF OVERLAND TRAIL AND AS FAR NORTH AS POSSIBLE EXISTING SANITARY SERVICE LINE SHOWN PER LOCATES AND LINE TRACING CORE DRILL EXISTING SANITARY MANHOLE AND CONNECT FUTURE SANITARY SERVICE LINE PROPOSED INV 4" (NW) = 5115.5 APPROXIMATE EXISTING WATER SERVICE LINE EXISTING WATER METER FUTURE 45° BEND FUTURE 22.5° BEND 30' FRONT SETBACK (SEE NOTE 12) APPROXIMATE FCLWD WATER LINE SHOWN PER UTILITY MAPPING PROVIDED BY THE CITY 1" = 10' 1" = N/A NORTH 10 / 3 0 / 2 0 2 4 10 : 4 4 : 2 3 A M C: \ U N I T E D C I V I L D R O P B O X \ P R O J E C T S \ U 2 4 0 0 1 - C A R L S O N U T I L I T Y P L A N \ C A D D \ C P \ C 3 . 0 0 - U T I L I T Y P L A N . D W G C3 . 0 0 - U T I L I T Y P L A N SM E NS C3.00 LO T 2 , V O N V I H L H E I G H T S T H I R D S U B D I V I S I O N UT I L I T Y P L A N 0 10'20' SCALE: 1" = 10' 5' 1 PR E P A R E D F O R : JOB NUMBER SHEET NUMBER SHEETSOF DA T E S U B M I T T E D : VERTICAL: HORIZONTAL: SCALE 2ND C I T Y SUB M I T T A L NOT F O R C O N S T R U C T I O N PR O J . M G R : DR A W I N G N A M E : PA T H : DE S I G N E R : DA T E : TI M E : Th e e n g i n e e r p r e p a r i n g t h e s e p l a n s w i l l n o t b e r e s p o n s i b l e f o r , o r l i a b l e f o r , u n a u t h o r i z e d ch a n g e s t o o r u s e s o f t h e s e p l a n s . A l l c h a n g e s t o t h e p l a n s m u s t b e i n w r i t i n g a n d m u s t be a p p r o v e d b y t h e p r e p a r e r o f t h e s e p l a n s . NO . BY DA T E CAUTION RE V I S I O N S : CIVIL ENGINEERING & CONSULTING UNITED CIVIL Design Group 19 OLD TOWN SQUARE #238 FORT COLLINS, CO 80524 (970) 530-4044 www.unitedcivil.com BR A D W . C A R L S O N 10 / 2 1 / 2 0 2 4 U24001 30 3 6 W E S T P R O S P E C T R D 1 LEGEND 1.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 2.EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 3.THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 4.THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY LATERALS 5' OUTSIDE OF BUILDING UNLESS NOTED OTHERWISE. EXACT LOCATIONS (HORIZONTAL AND VERTICAL) OF ALL UTILITY CONNECTIONS INTO THE PROPOSED BUILDING SHALL BE COORDINATED WITH APPROVED ARCHITECTURAL DRAWINGS. 5.WATER AND SEWER SERVICE PROVIDED BY THE CITY OF FORT COLLINS. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER CITY STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 6.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5'. MAXIMUM COVER SHALL BE 5.5'. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 8.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 9.SANITARY SEWER SERVICES SHALL BE SDR-35 PVC. 10.WATER SERVICES UP TO 1-1/2" SHALL BE TYPE K COPPER. 11.CONTRACTOR SHALL COORDINATE ALL UTILITY DEMOLITION AND/OR RELOCATION ITEMS WITH THE APPROPRIATE UTILITY PROVIDER PRIOR TO BEGINNING ANY ONSITE DEMOLITION. 12.BUILDING SETBACK OFF OF OVERLAND TRAIL IS TAKEN FROM EXISTING RIGHT-OF-WAY LINE. IF ADDITIONAL RIGHT OF WAY IS DEDICATED FOR OVERLAND TRAIL IN THE FUTURE, THIS SETBACK LINE WILL NEED ADJUSTED. CABLE TV LINE ELECTRIC LINE OVERHEAD ELECTRIC LINE FIBER OPTIC LINE GAS LINE IRRIGATION LINE SANITARY SERVICE FLARED END SECTION STORM INLET STORM MANHOLE STORM PIPE RIP RAP TELEPHONE LINE OVERHEAD TELEPHONE LINE FIRE HYDRANT FIRELINE WATER SERVICE WATER METER DRY UTILITY CONDUIT GATE VALVE FIBER, GAS, ELEC., TELE PEDESTAL NOTES