HomeMy WebLinkAboutVON VIHL HEIGHTS THIRD SUBDIVISION - BDR240007 - SUBMITTAL DOCUMENTS - ROUND 2 - Utility PlansW
P
R
O
S
P
E
C
T
R
D
SOUTH OVERLAND TRAIL
8" CLAY PIPE
60" STEEL WATER MAIN (FORT COLLINS)
12" CAST IRON WATER MAIN (FORT COLLINS)
FUTURE 4" SANITARY SERVICE
@ 2.0% MINIMUM SLOPE
LO
T
1
2
,
VO
N
V
I
H
L
H
E
I
G
H
T
S
SE
C
O
N
D
S
U
B
D
I
V
I
S
I
O
N
RE
C
E
P
T
I
O
N
N
O
.
7
7
8
7
3
4
(
1
9
6
0
)
30
'
R
I
G
H
T
O
F
W
A
Y
P
E
R
P
L
A
T
LOT 10,
VON VIHL HEIGHTS SUBDIVISION
RECEPTION NO. 765654 (1959)
30' RIGHT OF WAY PER PLAT
LO
T
1
1
,
VO
N
V
I
H
L
H
E
I
G
H
T
S
SE
C
O
N
D
S
U
B
D
I
V
I
S
I
O
N
RE
C
E
P
T
I
O
N
N
O
.
7
7
8
7
3
4
(
1
9
6
0
)
15' UTILITY EASEMENT
DEDICATED BY PLAT
5' UTILITY EASEMENT
RECEPTION NO. 765654 (1959)
15' REAR SETBACK
30' FRONT SETBACK (SEE NOTE 12)
5'
S
I
D
E
S
E
T
B
A
C
K
5'
S
I
D
E
S
E
T
B
A
C
K
17' PUBLIC AND PRIVATE UTILITY
EASEMENT DEDICATED BY PLAT
15' UTILITY EASEMENT
DEDICATED BY PLAT
13.5' RIGHT OF WAY
DEDICATED BY PLAT
LOT2
10,769 s.f.
LOT 1
11,697 s.f.
15
'
R
E
A
R
S
E
T
B
A
C
K
30
'
F
R
O
N
T
S
E
T
B
A
C
K
FUTURE CLEANOUT
FUTURE SANITARY SERVICE AND
CLEANOUT EXTENDED INTO LOT
EXISTING GROUND: 5125.3'
APPROX. 4" SERVICE INVERT: 5118.7'
EXISTING
BUILDING
EXISTING OVERHEAD ELECTRIC
EXISTING STORM LINE
EXISTING SIDEWALK
EXISTING ASPHALT DRIVE
EX
I
S
T
I
N
G
S
I
D
E
W
A
L
K
EXISTING DRIVEWAY CUT
EXISTING DRIVEWAY CUT
EXISTING GAS LINE
EX
I
S
T
I
N
G
A
S
P
H
A
L
T
D
R
I
V
E
EXISTING DRIVEWAY CUT
EXISTING FENCE
5' SIDE SETBACK
FUTURE ELECTRIC SERVICE
FUTURE GAS SERVICE
EX. SSMH RIM = 5125.9
INV 4" (NW) = 5117.5
INV 6" (N) = 5117.2
INV 4" (SW) = 5115.8
INV 8" (E) = 5115.3
15' UTILITY EASEMENT
DEDICATED BY PLAT
EXISTING 8" CAST IRON
WATER MAIN
(FORT COLLINS)
FUTURE WATER METER AND CURB STOP
FUTURE WATER SERVICE
FUTURE WATER SERVICE
EXTENDED INTO LOT
GAS SERVICE
EXTENDED INTO LOT
FUTURE ELECTRIC SERVICE
EXTENDED INTO LOT
5' DRAINAGE
EASEMENT
DEDICATED
BY PLAT
5' DRAINAGE EASEMENT
DEDICATED BY PLAT
5' DRAINAGE
EASEMENT
DEDICATED
BY PLAT
PROPOSED ACCESS TO LOT 1 TO BE CONSTRUCTED
OFF OVERLAND TRAIL AND AS FAR NORTH AS POSSIBLE
EXISTING SANITARY SERVICE LINE
SHOWN PER LOCATES AND LINE TRACING
CORE DRILL EXISTING SANITARY MANHOLE AND
CONNECT FUTURE SANITARY SERVICE LINE
PROPOSED INV 4" (NW) = 5115.5
APPROXIMATE EXISTING WATER SERVICE LINE
EXISTING WATER METER
FUTURE 45° BEND
FUTURE 22.5° BEND
30' FRONT SETBACK (SEE NOTE 12)
APPROXIMATE FCLWD WATER
LINE SHOWN PER UTILITY
MAPPING PROVIDED BY THE CITY
1" = 10'
1" = N/A
NORTH
10
/
3
0
/
2
0
2
4
10
:
4
4
:
2
3
A
M
C:
\
U
N
I
T
E
D
C
I
V
I
L
D
R
O
P
B
O
X
\
P
R
O
J
E
C
T
S
\
U
2
4
0
0
1
-
C
A
R
L
S
O
N
U
T
I
L
I
T
Y
P
L
A
N
\
C
A
D
D
\
C
P
\
C
3
.
0
0
-
U
T
I
L
I
T
Y
P
L
A
N
.
D
W
G
C3
.
0
0
-
U
T
I
L
I
T
Y
P
L
A
N
SM
E
NS
C3.00
LO
T
2
,
V
O
N
V
I
H
L
H
E
I
G
H
T
S
T
H
I
R
D
S
U
B
D
I
V
I
S
I
O
N
UT
I
L
I
T
Y
P
L
A
N
0 10'20'
SCALE: 1" = 10'
5'
1
PR
E
P
A
R
E
D
F
O
R
:
JOB NUMBER
SHEET NUMBER
SHEETSOF
DA
T
E
S
U
B
M
I
T
T
E
D
:
VERTICAL:
HORIZONTAL:
SCALE
2ND
C
I
T
Y
SUB
M
I
T
T
A
L
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
PR
O
J
.
M
G
R
:
DR
A
W
I
N
G
N
A
M
E
:
PA
T
H
:
DE
S
I
G
N
E
R
:
DA
T
E
:
TI
M
E
:
Th
e
e
n
g
i
n
e
e
r
p
r
e
p
a
r
i
n
g
t
h
e
s
e
p
l
a
n
s
w
i
l
l
n
o
t
b
e
r
e
s
p
o
n
s
i
b
l
e
f
o
r
,
o
r
l
i
a
b
l
e
f
o
r
,
u
n
a
u
t
h
o
r
i
z
e
d
ch
a
n
g
e
s
t
o
o
r
u
s
e
s
o
f
t
h
e
s
e
p
l
a
n
s
.
A
l
l
c
h
a
n
g
e
s
t
o
t
h
e
p
l
a
n
s
m
u
s
t
b
e
i
n
w
r
i
t
i
n
g
a
n
d
m
u
s
t
be
a
p
p
r
o
v
e
d
b
y
t
h
e
p
r
e
p
a
r
e
r
o
f
t
h
e
s
e
p
l
a
n
s
.
NO
.
BY
DA
T
E
CAUTION
RE
V
I
S
I
O
N
S
:
CIVIL ENGINEERING & CONSULTING
UNITED CIVIL
Design Group
19 OLD TOWN SQUARE #238
FORT COLLINS, CO 80524
(970) 530-4044
www.unitedcivil.com
BR
A
D
W
.
C
A
R
L
S
O
N
10
/
2
1
/
2
0
2
4
U24001
30
3
6
W
E
S
T
P
R
O
S
P
E
C
T
R
D
1
LEGEND
1.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE
FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE
CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR
SHALL CONTACT THE ENGINEER.
2.EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND
PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING
TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER.
THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF
SUCH INFORMATION. EXISTING UTILITY MAINS AND
SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED
ON THESE DRAWINGS. THE CONTRACTOR SHALL BE
RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND
PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT
UTILITY LOCATIONS.
3.THE PROPOSED CONSTRUCTION WILL BE IN CLOSE
PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE
CONTRACTOR SHALL COORDINATE WITH ALL UTILITY
PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO
MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING
BUILDINGS OR PROPERTIES.
4.THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY
LATERALS 5' OUTSIDE OF BUILDING UNLESS NOTED
OTHERWISE. EXACT LOCATIONS (HORIZONTAL AND
VERTICAL) OF ALL UTILITY CONNECTIONS INTO THE
PROPOSED BUILDING SHALL BE COORDINATED WITH
APPROVED ARCHITECTURAL DRAWINGS.
5.WATER AND SEWER SERVICE PROVIDED BY THE CITY OF
FORT COLLINS. ALL WATER AND SEWER CONSTRUCTION
SHALL BE PER CITY STANDARD CONSTRUCTION
SPECIFICATIONS, LATEST EDITION.
6.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE
4.5'. MAXIMUM COVER SHALL BE 5.5'.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM
SEPARATION BETWEEN ALL SANITARY SEWER & WATER
MAINS & SERVICES.
8.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY
REPRESENTED AND ARE NOT TO SCALE.
9.SANITARY SEWER SERVICES SHALL BE SDR-35 PVC.
10.WATER SERVICES UP TO 1-1/2" SHALL BE TYPE K COPPER.
11.CONTRACTOR SHALL COORDINATE ALL UTILITY DEMOLITION
AND/OR RELOCATION ITEMS WITH THE APPROPRIATE UTILITY
PROVIDER PRIOR TO BEGINNING ANY ONSITE DEMOLITION.
12.BUILDING SETBACK OFF OF OVERLAND TRAIL IS TAKEN FROM
EXISTING RIGHT-OF-WAY LINE. IF ADDITIONAL RIGHT OF
WAY IS DEDICATED FOR OVERLAND TRAIL IN THE FUTURE,
THIS SETBACK LINE WILL NEED ADJUSTED.
CABLE TV LINE
ELECTRIC LINE
OVERHEAD ELECTRIC LINE
FIBER OPTIC LINE
GAS LINE
IRRIGATION LINE
SANITARY SERVICE
FLARED END SECTION
STORM INLET
STORM MANHOLE
STORM PIPE
RIP RAP
TELEPHONE LINE
OVERHEAD TELEPHONE LINE
FIRE HYDRANT
FIRELINE
WATER SERVICE
WATER METER
DRY UTILITY CONDUIT
GATE VALVE
FIBER, GAS, ELEC., TELE PEDESTAL
NOTES