Loading...
HomeMy WebLinkAboutSCHOOLSIDE PARK - BDR240009 - SUBMITTAL DOCUMENTS - ROUND 3 - Irrigation Plans3" DIA 5' CANDECIDUOUS TREE 3" DIA 5' CANDECIDUOUS TREE 4" DIA 8' CANDECIDUOUS TREE 3" DIA 5' CANDECIDUOUS TREE 6" DIA 25' CANDECIDUOUS TREECLUSTER 10 10" DIA 20' CANCONIFEROUSTREE 26" DIA 30' CANCONIFEROUSTREE 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 14" DIA 30' CANDECIDUOUS TREE 15" DIA 30' CANDECIDUOUS TREE 11" DIA 20' CANDECIDUOUS TREE 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 6" DIA 20' CANDECIDUOUS TREECLUSTER 4 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 T B A B WP +42" AFGWP/GFI +42" AFGWP/GFI1 1 B B B B B P1-3,5 (4#10+#10G) 1" C,LTG CKT VIACONTACTOR ANDPHOTOCELL. REMOTE TYPE BDRIVER. COORDINATEEXACT LOCATION WITHARCHITECT. REMOTE TYPE BDRIVER. COORDINATEEXACT LOCATION WITHARCHITECT. A A A NHBZ NHBZ NHBZ NHBZ M M NHBZ NHBZ NATIVE TURF IRRIGATED SOD IRRIGATED SOD IRRIGATED SOD NATIVE TURF NATIVE TURF NATIVE TURF IRRIGATED SOD NATIVE TURF NATIVE TURF NATIVE TURF NATIVE TURF NATIVE TURF TWISTED ROOT DRIVE TI M B E R L I N E R O A D TI M B E R L I N E R O A D IRRIGATION POINT-OF-CONNECTION SOURCE: 1.5-INCH METER (RE: CIVIL) TAPPED INTO 16-INCH DUCTILE IRON WATERLINE SIZE: 1.5-INCH MAXIMUM FLOW: 50 GPM MINIMUM PRESSURE: 85 PSI AVAILABLE PRESSURE: 85 PSI BACKFLOW PREVENTER HOUSED WITHIN A SOLID SIDED ENCLOSURE (REFER TO LEGEND) IRRIGATION CONTROLLER *WALL MOUNTED *INSTALLED WITHIN RESTROOM MECHANICAL ROOM *REQUIRES 120 VAC POWER 16" DUCTILE IRON WATER LINE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT ZONE RE: LANDSCAPE NOTE: ENLARGE TREE RINGS FOR EXISTING TREES AS NECESSARY, TYPICAL NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE 1 2 3 4 6 7 1.5" SERVICE LINE (RE: CIVIL) 1.5" TYPE K COPPER 1.5" PVC 2.5" PVC 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5"2.5"2.5"2.5"2.5"2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2" 1.5" 2" 2" 1.25" 1.25" 1.25" 1.25" 2.5" 1.5" 1.25" 2.5" 2.5" 2.5" 2.5"2.5" 1.25"1.25" 1.5" 1.25" 1.5" 1.5"1.25"1.25" 1.5" 1.5" 1.25" 1.25" 2" 1.5"1.25" 2" 1.25" 1.25" 1.25"1.25" 1.25" 1.5"1.25" 1.25" 1.25" 1.25" 2" 1.25" 1.25" 1.25" 2.5" 1.5" 1.5" 1.25" 1.25" 1.25" 1.25" 2" 2" 2.5"2.5" 1.5" 1.25" 1.25" 1.5" 1.5" 1.25" 1.25" 2" 2.5" 1.5" 1.5" 1.25" 1.25" 1.5" 1.5"1.25"1.25" 2" 1.25" 2" 2" 1.25" 2" 1.5" 1.5" 1.25" 1.25" 1.25" 2" 1.25" 1.25" 1.25" 2" 2" 1.5" 1.5" 1.25" 1.25" 1.25" 1.25" 1.25"1.25" 1.5" 1.5"1.25"1.25" 2" 1.5" 1.5" 1.25" 1.25" 2" 2" 1.25"1.25" 1.5" 1.5"1.25" 1.25" 14 14 14 14 14 14 14 14 14 14 14 14 14 18 6 4 4 4 4 4 4 4 4 Q25 W M F B A 14 14 4 44444 4 18 18 18 10 10 14 14 10 Q35 Q35 A41 1.5" 28 T 10 10 4 4 10 14 14 14 14 Q35 Q35 Q35 H35 H35 H35 H35 H35 H35 H35 H35 H35 F35 F25 A43 1.5"39 SD A44 1.5"47 SD A45 1.5" 31 SD A49 1.5"46 SD A48 1.5" 47 SD A29 1.5" 47 SD A36 1.5" 45 SD A35 1.5"33 SD A31 1" 11 SD A30 1.5"26 SD A34 1.5" 32 SD A28 1" 12 SD A19 1.5" 44 T A20 1.5" 49 T A21 1.5"25 T A22 1.5"25 T A23 1.5"38 T A24 1"22 T A25 1.5" 50 T Q A11 1" - P A1 1.5" 32 SD A2 1" 17 SD QQ Q Q Q Q Q Q 5 5A5 1" - P 5 G G 5 G G 5 5 G G 55 G5G G 5 6 6 6 6 6 6 A4 1.5" 26 T A46 1.5"33 T 10 A47 1"2 TR LT T T LT A37 1" 4 TR LT LT T TT T T LT T T T TT T T T T A33 1" 15 TR T T T T T T T T A26 1" 5 TR T T T T T T T T T LT LT LT LT T T T T LT A9 1" 13 TR TT T LT LTLT LT T T A12 1"4 TR LT LT LT 6 T T T T T T T T A6 1" 3 TR T T T 4 4 8 T T TT T T T T TT T T T T T 8 8 8 8 T 8 8 4 8 8 8 8 8 8 88 A16 1.5"33 SD A17 1.5"37 SD A18 1.5"41 SD A3 1.5" 26 SD Q30 H30 H30 H35 Q35 H35 H25 Q35 H35 H25 Q25 H25 H25 H25 H25 H25 H25 H30 H30 Q35 Q35 H30 H35 H35 H35 H35 H25 H25 Q25H35 H35 F35 F35 F30 F25 A8 1.5" 26 SD T A15 1.5" 34 SD A10 1.5"31 SD G T 6 6 T 6 4 8 8 10 101046 1414 A40 1.5" 27 SD A39 1.5" 28 SD Q35 H35 Q35 H35 F30 H25 A13 1.5"32 T A14 1.5" 34 T T LT T LT T LT LT 4 4 4 4 Q35Q35 Q35 Q35 H35 H35 H35 H35 Q35 H25H25 H25H25H30 H30 Q25 F30 F30 A38 1.5" 45 SD T T A27 1" 2 P T LT T LT 5 G LT LT 4 4 4 4 4 LT T 8 8 Q30 H30 H25 H25 H25Q25 H25 Q25 H25 LT LT Q 6 A42 1"6 TR G 5 Q35 H35 H35 T Q 5 G 6 H35 A7 1"9 TR LT T T T H30 F25 H25 H25 H30 H25 H30 H30 H30 F25 F25 12 Q35 H35 H35 Q25 H35 Q25 T T T T T T T T T T T T T T T T T T T T T T T T A32 1" 10 SD 8 8 8 8 8 IRRIGATION COVER SHEET SLEEVING *TYPE: CLASS 200 PVC *SIZE AND QUANTITY: REFER TO PLANS MAINLINE PIPE *TYPE: HDPE DR11 PE4710 *SIZE AS SHOWN LATERAL PIPE TO SPRINKLERS *TYPE: CLASS 200 PVC *1-INCH UNLESS OTHERWISE NOTED MANIFOLD PIPE *TYPE: CLASS 200 PVC *1-INCH UNLESS OTHERWISE NOTED LATERAL PIPE TO INLINE DRIP RINGS *TYPE: HDPE DR11 *1-INCH UNLESS OTHERWISE INDICATED DRIP LATERAL PIPE TO EMITTERS *TYPE: RAIN BIRD XT-700 *3/4-INCH SIZE UNLESS OTHERWISE NOTED *EMITTER TYPE: RAIN BIRD XERI-BUG *DO NOT EXCEED 450-FEET OF DRIP LATERAL AND 8 GPM PER ZONE. NUMBER OF PLANTS NOT KNOWN DURING DESIGN, FIELD ADJUST AND ADD DRIP ZONES IF NEEDED. UNCONNECTED PIPE CROSSING POINT-OF-CONNECTION (P.O.C.) MASTER VALVE WIRING AND FLOW SENSOR CABLE ROUTING *REFER TO FLAG NOTES FOR ADDITIONAL INFORMATION *ROUTE ADJACENT TO MAINLINE TO IRRIGATION CONTROLLER *MAKE ALL NECESSARY CONNECTIONS WINTERIZATION ASSEMBLY *REFER TO DETAIL BACKFLOW PREVENTION ASSEMBLY *MODEL: FEBCO 825YA *SIZE: 1-1/2-INCH *ENCLOSURE: VIT STRONGBOX SBBC SERIES (SIZED AS NEEDED) MASTER VALVE ASSEMBLY *MODEL: RAIN BIRD PEB (1-1/2-INCH) *WIRE DIRECTLY TO CONTROLLER PER MANUFACTURER'S GUIDELINES FLOW SENSOR ASSEMBLY *MODEL: HYDROPOINT FLOWHD PLASTIC (1-1/2-INCH) *WIRE DIRECTLY TO CONTROLLER PER MANUFACTURER'S GUIDELINES BLOW OUT ASSEMBLY *REFER TO DETAIL ISOLATION GATE VALVE ASSEMBLY *MODEL: LEEMCO LMV-BBHDSS SERIES *NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE QUICK COUPLING VALVE ASSEMBLY *MODEL: RAIN BIRD 5RC REMOTE CONTROL VALVE ASSEMBLY *MODEL:RAIN BIRD PEB *SIZE AS SHOWN ON PLANS *DECODER: WEATHERTRAK WT2W-SVD-11 DRIP REMOTE CONTROL VALVE ASSEMBLY *REMOTE CONTROL VALVE MODEL: RAIN BIRD PEB *FILTER MODEL: RAIN BIRD PRB-100 *DECODER: WEATHERTRAK WT2W-SVD-11 IRRIGATION LEGEND Q B M F ZONE CONTROL VALVE *MODEL: SPEARS PVC COMPACT *SIZE: 1-INCH FLUSH CAP ASSEMBLY *MODEL: RAIN BIRD TREE/SHRUB RING ASSEMBLY *REFER TO DETAIL 10' DIAMETER TREE RING ASSEMBLY *REFER TO DETAIL POP-UP SPRINKLER: RAIN BIRD MPR SERIES ON 1806-SAM-PRS @ 30 PSI RADIUS:5'FLOW (GPM): Q - 0.10 H - 0.20 F - 0.41 RADIUS:8'FLOW (GPM): Q - 0.26 H - 0.52 F - 1.05 RADIUS:10' FLOW (GPM): Q - 0.39 H - 0.79 F - 1.58 RADIUS:12' FLOW (GPM): Q - 0.65 H - 1.30 F - 2.60 RADIUS: 15' FLOW (GPM): Q - 0.92 H - 1.85 F - 3.70 RADIUS:4'x'30 FLOW (GPM): SST - 1.21 RADIUS: 4'x'15 FLOW (GPM): EST - 0.61 POP-UP GEAR-DRIVEN ROTORS: RAIN BIRD 5004+-PC-SAM-R-SS-MPR @ 45 PSI RADIUS:25'FLOW (GPM): Q-0.88 H-1.73 F-3.34 RADIUS:30'FLOW (GPM): Q-1.23 H-2.59 F-5.08 RADIUS:35'FLOW (GPM): Q-1.67 H-3.33 F-6.62 POP-UP GEAR-DRIVEN ROTORS: RAIN BIRD FALCON 6504-SS @ 50 PSI *NO HALO IS PART CIRCLE. HALO IS FULL CIRCLE *NUMBER WITHIN IS NOZZLE NOZZLE FLOW(GPM)RADIUS(FEET) 4 3.7 41' 6 5.5 49' 8 7.4 51' 10 9.1 53' 14 12.7 59' 18 15.4 59' IRRIGATION CONTROLLER ASSEMBLY CONTROLLER "A": WEATHERTRAK ET PRO3 2-WIRE, 96 STATIONS AVAILABLE, 48 STATIONS USED *MODEL WTPRO3-C-2W96-SPT *ADD-ON: WTOF-KEY (FOR OPTIFLOW XR COMPATIBILITY) *ADD-ON: ANT-OMNI AND ANT-CX-CBL (OMNI ANTENNAE AND CABLE - LENGTH AS REQUIRED) *CELLULAR COMMUNICATIONS *COLD-ROLLED STEEL WALL MOUNT ENCLOSURE *LINE SURGE PROTECTION FOR TWO-WIRE PATH: WT2W-LSP CONTROL NOTES: 1.INSTALL TWO WIRE CABLE, PAIGE ELECTRIC P7072D, FOR THE CONTROLLER PER MANUFACTURER'S GUIDELINES. 2.GROUND TWO WIRE CABLE PER MANUFACTURER'S GUIDELINES. INSTALL RAIN SENSOR PER DETAILS. 3.CONTRACTOR TO COORDINATE THIRD PARTY TWO WIRE REVIEW BY CPS DISTRIBUTORS (CONTACT DENNIS LYNCH, PHONE: 720-666-8025). TWO WIRE GROUNDING *INSTALL PER MANUFACTURER'S GUIDELINES IRRIGATION WIRE ROUTING *NOTE THAT THERE IS A SPARE TWO WIRE CABLE REQUIRED. REFER TO TRENCH DETAIL. INSTALL SPARE WIRE WITH ALL MAINLINE AND COILED (30-INCH COIL LENGTH) WITH ALL VALVE BOXES. SPARE WIRE TO HAVE DIFFERENT INSULATION COLOR THAN PRIMARY TWO WIRE CABLE. INDICATES CONTROLLER AND CONTROLLER STATION NUMBER INDICATES LATERAL DISCHARGE IN GPM INDICATES REMOTE CONTROL VALVE SIZE IN INCHES T = TURF, P = PLANTINGS, TR = TREE, SD = SEED NOTE: 1.VALVE BOXES - RAIN BIRD VB SERIES (LID COLOR: GREEN IN TURF, BROWN IN SHRUB BEDS) OR EQUAL. REFER TO DETAILS FOR VALVE BOX SIZES. A-1 1" 15 T A ES SS 25 Q25 H 25 F 30 Q30H30 F 35 Q 35 H 35 F 2 G 14 14 T LT FLAG NOTES 1 EXCAVATE AND EXPOSE COPPER STUB-OUT AT THE APPROXIMATE LOCATION SHOWN. CONNECT TO COPPER PIPE AND EXTEND TYPE K COPPER PIPE TO WINTERIZATION ASSEMBLY. COORDINATE EXACT PLACEMENT OF WINTERIZATION, BACKFLOW, MASTER VALVE, AND FLOW SENSOR ASSEMBLIES WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. INSTALL WALL MOUNT IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION INDICATED WITHIN RESTROOM MECHANICAL ROOM. ELECTRICAL POWER WILL BE PROVIDED TO CONTROLLER LOCATION. COORDINATE EXACT LOCATION OF ELECTRICAL POWER WITH THE ELECTRICAL DRAWINGS AND NECESSARY TRADES ON SITE. PROVIDE ALL CONDUIT AND CONDUCTORS BETWEEN ELECTRICAL POWER SOURCE AND IRRIGATION CONTROLLER AND MAKE ALL CONNECTIONS. COORDINATE EXACT PLACEMENT OF CONTROLLER WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. CONNECT MASTER VALVE AND FLOW SENSOR TO RESPECTIVE IRRIGATION CONTROLLER PER MANUFACTURER'S GUIDELINES. PROGRAM HIGH FLOW POINT TO 150% OF MAXIMUM FLOW SHOWN ON PLANS. THE MASTER VALVE AND FLOW SENSOR ARE TO BE WIRED DIRECTLY TO THE IRRIGATION CONTROLLER. INSTALL 14 AWG DIRECT BURY IRRIGATION WIRING FOR THE MASTER VALVE AND PAIGE SPEC P7162D-A CABLE FOR THE FLOW SENSOR. INSTALL MASTER VALVE WIRING AND FLOW SENSOR CABLE ADJACENT TO THE MAINLINE PIPE TO THE IRRIGATION CONTROLLER. INSTALL TWO WIRE CABLES 24-INCHES BELOW GRADE BETWEEN CONTROLLER AND MAINLINE PIPE. INSTALL A PRIMARY AND SECONDARY TWO WIRE CABLE. INSTALL DETECTABLE WARNING TAPE 6-INCHES BELOW GRADE CENTERED OVER TWO WIRE CABLES. COORDINATE TWO WIRE CABLES' INSTALLATION WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. INSTALL IRRIGATION DECODER GROUNDING EQUIPMENT THAT MEETS CONTROLLER MANUFACTURER'S GUIDELINES AT LOCATION ADJACENT TO INDICATED REMOTE CONTROL VALVE ASSEMBLY. COORDINATE EXACT LOCATION OF GROUNDING EQUIPMENT WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR GROUNDING THE ENTIRE TWO WIRE PATH PER MANUFACTURER'S GUIDELINES. INSTALL SLEEVES (1, 6-INCH AND 1, 2-INCH) FOR MAINLINE AND TWO WIRE CABLES. INSTALL MAINLINE THROUGH THE 6-INCH SLEEVE AND THE TWO WIRE CABLES THROUGH THE 2-INCH SLEEVE. INSTALL NYLON PULL CORD THROUGH EACH SLEEVE INTENDED TO EASE INSTALLATION OF MAINLINE AND TWO WIRE THROUGH THEIR RESPECTIVE SLEEVE. COORDINATE SLEEVING INSTALLATION WITH THE OWNER'S REPRESENTATIVE AND GENERAL CONTRACTOR ON SITE PRIOR TO CONSTRUCTION. INSTALL MASTER VALVE WIRING AND FLOW SENSOR CABLE ADJACENT TO MAINLINE PIPE. COORDINATE MASTER VALVE WIRING AND FLOW SENSOR CABLE INSTALLATION WITH THE OWNER'S REPRESENTATIVE ON SITE PRIOR TO CONSTRUCTION. COORDINATE EXACT TREE RING SIZE, SHAPE AND ORIENTATION FOR THE IDENTIFIED TREES WITH CITY FORESTER PRIOR TO CONSTRUCTION. 2 3 4 5 6 7 8 GENERAL DESCRIPTION A FULLY AUTOMATED SPRINKLER AND DRIP IRRIGATION SYSTEM WILL IRRIGATE TURF, PLANTING BEDS, TREES, AND SEED MIX. POP-UP SPRINKLERS IRRIGATE TURF AND SEED MIX. POINT SOURCE DRIP IRRIGATES PLANTING BEDS. TREES ARE IRRIGATED WITH INLINE DRIP RINGS (SEPARATE ZONES FOR TREES IN SEED, TURF, AND PLANTING BEDS). MUNICIPAL (POTABLE) WATER IS USED FOR IRRIGATION. THE POINT-OF-CONNECTION (P.O.C.) IS SHOWN ON THE PLANS IMMEDIATELY DOWNSTREAM OF THE IRRIGATION WATER METER (THE METER IS TO BE INSTALLED BY OTHERS). REFER TO CIVIL PLANS FOR IRRIGATION WATER METER DETAIL AND DESIGN. A NEW TWO WIRE IRRIGATION CONTROLLER IS REQUIRED. A MASTER VALVE AND FLOW SENSOR WILL BE INSTALLED TO FACILITATE AUTOMATIC SHUT DOWN OF THE IRRIGATION SYSTEM IN THE EVENT OF A MAINLINE PIPE BREAK AND PROVIDE FLOW DATA, FOR REPORTING PURPOSES, TO THE IRRIGATION CONTROLLER. ISOLATION GATE VALVES PERMIT THE ISOLATION OF SECTIONS OF THE SYSTEM FOR REPAIRS OR MAINTENANCE. QUICK COUPLING VALVES HAVE BEEN PROVIDED THROUGHOUT THE SITE FOR INCIDENTAL WATERING. CITY OF FORT COLLINS STANDARD IRRIGATION DESIGN AND CONSTRUCTION CRITERIA ARE FOLLOWED. GENERAL NOTES 1.THE SYSTEM DESIGN ASSUMES A MINIMUM STATIC PRESSURE AND MAXIMUM FLOW DEMAND AS SHOWN ON THE PLANS FOR THE POINT-OF-CONNECTION (P.O.C.). THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE. 2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING, OR IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED. BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A. IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHEREVER POSSIBLE. B. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF CROSS TYPE FITTINGS IS NOT PERMITTED. 6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A. TWO OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVE. 7.SELECT NOZZLES FOR SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND UNIFORM COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF EACH SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE TO BE INSTALLED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED REQUIRES HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 9.CONNECT ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.WITH REGARD TO PIPE SIZING, THE FOLLOWING SHOULD BE NOTED: A. IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN TWO IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11.INSTALL VAN NOZZLES WHERE SPRAY ANGLES ARE LESS OR GREATER THAN WHAT A FIXED SPRAY NOZZLE CAN IRRIGATE WITHOUT EXCESSIVE OVERSPRAY. KEYMAP N.T.S. IR2.0 IR2.1 IR2.2 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR1.0 3" DIA 5' CANDECIDUOUS TREE 4" DIA 8' CAN DECIDUOUS TREE 3" DIA 5' CANDECIDUOUS TREE 6" DIA 25' CANDECIDUOUS TREECLUSTER 10 10" DIA 20' CANCONIFEROUS TREE 26" DIA 30' CAN CONIFEROUSTREE 10" DIA 15' CAN CONIFEROUSTREE CLUSTER 2 14" DIA 30' CANDECIDUOUS TREE 15" DIA 30' CANDECIDUOUS TREE 11" DIA 20' CANDECIDUOUS TREE 10" DIA 15' CANCONIFEROUS TREE CLUSTER 2 6" DIA 20' CAN DECIDUOUS TREECLUSTER 4 10" DIA 15' CANCONIFEROUS TREE CLUSTER 2 T US E US E US E UBE UBE UBE UBE UBE UB E UB E UB E UB E UB E UB E UB E UB E B A B WP +42" AFG WP/GFI +42" AFG WP/GFI1 1 B B B B B P1-3,5 (4#10+#10G) 1" C, LTG CKT VIA CONTACTOR AND PHOTOCELL. REMOTE TYPE B DRIVER. COORDINATE EXACT LOCATION WITH ARCHITECT. REMOTE TYPE B DRIVER. COORDINATE EXACT LOCATION WITH ARCHITECT. A A A NHBZ NHB Z NHBZ NHB Z M M NHB Z NHBZ NATIVE TURF IRRIGATED SOD IRRIGATED SOD IRRIGATED SOD NATIVE TURF NATIVE TURF NATIVE TURF IRRIGATED SOD NATIVE TURF NATIVE TURF NATIVE TURF NATIVE TURF NATIVE TURF TI M B E R L I N E R O A D TI M B E R L I N E R O A D IRRIGATION POINT-OF-CONNECTION SOURCE: 1.5-INCH METER (RE: CIVIL) TAPPED INTO 16-INCH DUCTILE IRON WATERLINE SIZE: 1.5-INCH MAXIMUM FLOW: 50 GPM MINIMUM PRESSURE: 85 PSI AVAILABLE PRESSURE: 85 PSI BACKFLOW PREVENTER HOUSED WITHIN A SOLID SIDED ENCLOSURE (REFER TO LEGEND) IRRIGATION CONTROLLER *WALL MOUNTED *INSTALLED WITHIN RESTROOM MECHANICAL ROOM *REQUIRES 120 VAC POWER 16" DUCTILE IRON WATER LINE 2 2 2 NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT ZONE RE: LANDSCAPE NOTE: ENLARGE TREE RINGS FOR EXISTING TREES AS NECESSARY, TYPICAL NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE 1 2 3 4 6 7 1.5" SERVICE LINE (RE: CIVIL) 1.5" TYPE K COPPER 1.5" PVC 2.5" PVC 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5"2.5"2.5"2.5"2.5"2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2" 1.5" 2" 2" 1.25" 1.25" 1.25" 1.25" 2.5" 1.5" 1.25" 2.5" 2.5" 2.5" 2.5"2.5" 1.25"1.25" 1.5" 1.25" 1.5" 1.5"1.25"1.25" 1.5" 1.5" 1.25" 1.25" 2" 1.5"1.25" 2" 1.25" 1.25" 1.25"1.25" 1.25" 1.5"1.25" 1.25" 1.25" 1.25" 2" 1.25" 1.25" 1.25" 2.5" 1.5" 1.5" 1.25" 1.25" 1.25" 1.25" 2" 2" 2.5"2.5" 1.5" 1.25" 1.25" 1.5" 1.5" 1.25" 1.25" 2" 2.5" 1.5" 1.5" 1.25" 1.25" 1.5" 1.5"1.25"1.25" 2" 1.25" 2" 2" 1.25" 2" 1.5" 1.5" 1.25" 1.25" 1.25" 2" 1.25" 1.25" 1.25" 2" 2" 1.5" 1.5" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.5" 1.5"1.25"1.25" 2" 1.5" 1.5" 1.25" 1.25" 2" 2" 1.25" 1.25" 1.5" 1.5"1.25" 1.25" 14 14 14 14 14 14 14 14 14 14 14 14 14 18 6 4 4 4 4 4 4 4 4 Q25 W M F B A 14 14 4 44444 4 18 18 18 10 10 14 14 10 Q35 Q35 A41 1.5" 28 T 10 10 4 4 10 14 14 14 14 Q35 Q35 Q35 H35 H35 H35 H35 H35 H35 H35 H35 H35 F35 F25 A43 1.5" 39 SD A44 1.5" 47 SD A45 1.5" 31 SD A49 1.5" 46 SD A48 1.5" 47 SD A29 1.5" 47 SD A36 1.5" 45 SD A35 1.5" 33 SD A31 1" 11 SD A30 1.5" 26 SD A34 1.5" 32 SD A28 1" 12 SD A19 1.5" 44 T A20 1.5" 49 T A21 1.5" 25 T A22 1.5" 25 T A23 1.5" 38 T A24 1" 22 T A25 1.5" 50 T Q A11 1" - P A1 1.5" 32 SD A2 1" 17 SD QQ Q Q Q Q Q Q 5 5 A5 1" - P 5 G G 5 G G 5 5 G G 55 G5G G 5 6 6 6 6 6 6 A4 1.5" 26 T A46 1.5" 33 T 10 A47 1" 2 TR LT T T LT A37 1" 4 TR LT LT T TT T T LT T T T T T T T T T A33 1" 15 TR T T T T T T T T A26 1" 5 TR T T T T T T T T T LT LT LT LT T T T T LT A9 1" 13 TR TT T LT LTLT LT T T A12 1" 4 TR LT LT LT 6 T T T T T T T T A6 1" 3 TR T T T 4 4 8 T T TT T T T T TT T T T T T 8 8 8 8 T 8 8 4 8 8 8 8 8 8 88 A16 1.5" 33 SD A17 1.5" 37 SD A18 1.5" 41 SD A3 1.5" 26 SD Q30 H30 H30 H35 Q35 H35 H25 Q35 H35 H25 Q25 H25 H25 H25 H25 H25 H25 H30 H30 Q35 Q35 H30 H35 H35 H35 H35 H25 H25 Q25H35 H35 F35 F35 F30 F25 A8 1.5" 26 SD T A15 1.5" 34 SD A10 1.5" 31 SD G T 6 6 T 6 4 8 8 10 101046 1414 A40 1.5" 27 SD A39 1.5" 28 SD Q35 H35 Q35 H35 F30 H25 A13 1.5" 32 T A14 1.5" 34 T T LT T LT T LT LT 4 4 4 4 Q35 Q35 Q35 Q35 H35 H35 H35 H35 Q35 H25H25 H25H25 H30 H30 Q25 F30 F30 A38 1.5" 45 SD T T A27 1" 2 P T LT T LT 5 G LT LT 4 4 4 4 4 LT T 8 8 Q30 H30 H25 H25 H25Q25 H25 Q25 H25 LT LT Q 6 A42 1" 6 TR G 5 Q35 H35 H35 T Q 5 G 6 H35 A7 1" 9 TR LT T T T H30 F25 H25 H25 H30 H25 H30 H30 H30 F25 F25 12 Q35 H35 H35 Q25 H35 Q25 T T T T T T T T T T T T T T T T T T T T T T T T A32 1" 10 SD 8 8 8 8 8 OVERALL IRRIGATION PLAN 0'30'15'60'90' 1"=30' IR2.0 IR2.1 IR2.2 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR1.1 10" DIA 20' CANCONIFEROUSTREE 26" DIA 30' CANCONIFEROUSTREE 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 14" DIA 30' CANDECIDUOUS TREE 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 6" DIA 20' CANDECIDUOUS TREECLUSTER 4 10" DIA 15' CANCONIFEROUSTREE CLUSTER 2 T US E US E US E US E US E US E UBE UBE UBE UBE UBE UBE UBE UBE UB E NHB Z NHBZ NATIVE TURF IRRIGATED IRRIGATED SOD TI M B E R L I N E R O A D IRRIGATION POINT-OF-CONNECTION SOURCE: 1.5-INCH METER (RE: CIVIL) TAPPED INTO 16-INCH DUCTILE IRON WATERLINE SIZE: 1.5-INCH MAXIMUM FLOW: 50 GPM MINIMUM PRESSURE: 85 PSI AVAILABLE PRESSURE: 85 PSI BACKFLOW PREVENTER HOUSED WITHIN A SOLID SIDED ENCLOSURE (REFER TO LEGEND) 16" DUCTILE IRON WATER LINE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NOTE: ENLARGE TREE RINGS FOR EXISTING TREES AS NECESSARY, TYPICAL NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE 1 3 6 7 1.5" SERVICE LINE (RE: CIVIL) 1.5" TYPE K COPPER 1.5" PVC 2.5" PVC 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5"2.5" 2.5" 2.5" 2" 1.5" 2" 2" 2.5" 1.5" 1.25" 1.25"1.25" 1.5" 1.5"1.25"1.25" 1.5" 1.5" 1.25" 1.25" 1.5"1.25" 1.25" 1.25" 1.25" 2.5" 1.5" 1.25" 1.25" 1.5" 1.5" 1.25" 1.25" 2" 2.5"2" 1.5" 1.5" 1.25" 1.25" 1.25" 2" 1.25" 1.25" 1.25" 1.25" 1.25" 1.5" 1.5"1.25"1.25" 2" 1.5" 1.5" 1.25" 1.25" 14 14 14 14 18 W M F B 14 18 10 14 14 10 Q 35 Q35 Q35 H35 H35 H35 H 35 H35 H 35 H35 H35 H 35 F 35 F25 A49 1.5" 46 SD A48 1.5" 47 SD A19 1.5" 44 T A20 1.5" 49 T A21 1.5" 25 T A22 1.5" 25 T Q A11 1" - P A1 1.5" 32 SD A2 1" 17 SD Q Q Q Q 5 5 A5 1" - P 5 G G 5 G G 5 G 5 6 6 6 A4 1.5" 26 T A47 1" 2 TR T T T LT LT LT LT T T T T LT A9 1" 13 TR TT T LT LTLT LT T T A12 1" 4 TR LT LT LT 6 T T T T T T T T A6 1" 3 TR T T T 4 4 8 T T TT T T T T TT T T T T T 8 8 8 8 T 8 8 4 8 8 8 8 8 8 88 A16 1.5" 33 SD A17 1.5" 37 SD A18 1.5" 41 SD A3 1.5" 26 SD Q30 H 30 H 30 H35 Q35 H 35 H25 Q 35 H 35 H 25 Q 25 H 25 H 25 H 25 H 25 H 25 H 25 H 30 H 30 Q35 Q35 H 30 H 35 H35 H 35 H35 H25 H25 Q 25H 35 H35 F 35 F 35 F30 F25 A8 1.5" 26 SD T A15 1.5" 34 SD A10 1.5" 31 SD G T 6 6 T A13 1.5" 32 T A14 1.5" 34 T T LT T 4 8 8 LT Q 5 G 6 H 35 A7 1" 9 TR LT T T T T T 8 8 8 IRRIGATION PLAN 0'20'10'40'60' 1"=20' MATCHLINE SEE SHEET IR2.1 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR2.0 NATURAL HABITAT BUFFER ZONE *REFER TO LANDSCAPE PLANS *THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 5.6 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. NATURAL HABITAT BUFFER ZONE NOTE NOTE: MEDIAN IRRIGATION NOT A PART OF THE PARK DEVELOPMENT REVIEW 15" DIA 30' CANDECIDUOUS TREE 11" DIA 20' CANDECIDUOUS TREE UB E UB E UB E UB E UB E UB E UB E UB E UB E UB E UB E UB E UB E B A B WP +42" AFG WP/GFI +42" AFG WP/GFI1 1 B B B B B P1-3,5 (4#10+#10G) 1" C, LTG CKT VIA CONTACTOR AND PHOTOCELL. REMOTE TYPE B DRIVER. COORDINATE EXACT LOCATION WITH ARCHITECT. REMOTE TYPE B DRIVER. COORDINATE EXACT LOCATION WITH ARCHITECT. A A A M M IRRIGATED SOD IRRIGATED SOD NATIVE TURF NATIVE TURF IRRIGATED SOD NATIVE TURF NATIVE TURF TI M B E R L I N E R O A D IRRIGATION CONTROLLER *WALL MOUNTED *INSTALLED WITHIN RESTROOM MECHANICAL ROOM *REQUIRES 120 VAC POWER 2 2 2 2 2 NATURAL HABITAT ZONE RE: LANDSCAPE 2 4 2.5" 2.5" 2.5" 2.5"2.5"2.5"2.5" 2.5" 2.5" 2.5" 1.25" 1.25" 1.25" 1.5" 1.25" 2" 1.5"1.25" 2" 1.25" 1.25" 1.25"1.25" 1.25" 2" 1.25" 1.25" 1.25" 1.25" 1.25" 2" 2" 2.5"2.5" 1.25" 1.5" 1.5" 1.25" 1.25" 2" 1.25" 2" 2" 1.25" 14 14 14 14 14 14 14 14 14 14 18 6 A 14 14 18 18 10 10 Q 35 Q 35 A41 1.5" 28 T 10 10 4 4 14 14 14 14 A43 1.5" 39 SD A44 1.5" 47 SD A45 1.5" 31 SD A23 1.5" 38 T A24 1" 22 T A25 1.5" 50 T Q Q 5 G 5 G 6 A46 1.5" 33 T 10 LT T T LT A37 1" 4 TR T T T T T T A26 1" 5 TR T T T T T T T T 6 4 8 8 10 101046 1414 A40 1.5" 27 SD A39 1.5" 28 SD Q35 H 35 Q35 H35 F 30 H 25 T LT T Q 35 Q35 Q 35 H35 H 35 H35 H35 H25H25 H25H25 H 30 H 30 Q25 F 30 F 30 A38 1.5" 45 SD T T 5 G LT LT 4 4 4 4 4 LT LT Q 6 A42 1" 6 TR G 5 Q35 H 35 H 35 T T T T T T T T T T T T T T T T T T T T T T T 8 8 IRRIGATION PLAN 0'20'10'40'60' 1"=20' MATCHLINE SEE SHEET IR2.0 MA T C H L I N E S E E S H E E T I R 2 . 2 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR2.1 NATURAL HABITAT BUFFER ZONE *REFER TO LANDSCAPE PLANS *THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 5.6 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. NATURAL HABITAT BUFFER ZONE NOTE 3" DIA 5' CANDECIDUOUS TREE 3" DIA 5' CANDECIDUOUS TREE 4" DIA 8' CANDECIDUOUS TREE 3" DIA 5' CANDECIDUOUS TREE 6" DIA 25' CANDECIDUOUS TREECLUSTER 10 NHBZ NHB Z NHBZ NHB Z NATIVE TURF NATIVE TURF NATIVE TURF NATIVE TURF NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE NATURAL HABITAT BUFFER ZONE RE: LANDSCAPE 2.5" 2.5" 2.5"2.5" 1.25" 2.5" 2.5" 2.5" 2.5"2.5" 1.5" 1.5" 1.25" 1.25" 1.5" 1.5"1.25"1.25" 2" 2" 1.5" 1.5" 1.25" 1.25" 1.25" 1.25" 2" 2" 1.25" 1.25" 1.5" 1.5"1.25" 1.25" 4 4 4 4 4 4 4 4 Q 25 4 44444 4 A29 1.5" 47 SD A36 1.5" 45 SD A35 1.5" 33 SD A31 1" 11 SD A30 1.5" 26 SD A34 1.5" 32 SD A28 1" 12 SD Q Q G 55 G 6 6 LT LT T TT T T LT T T T T T T T T T A33 1" 15 TR LT T LT LT 4 4 4 4 Q 35 Q35 A27 1" 2 P LT LT T Q30 H30 H 25 H25 H25Q25 H25 Q 25 H25 H 30 F 25 H 25 H 25 H30 H25 H30 H 30 H 30 F 25 F25 12 Q35 H35 H35 Q25 H35 Q 25 A32 1" 10 SD IRRIGATION PLAN 0'20'10'40'60' 1"=20' MA T C H L I N E S E E S H E E T I R 2 . 1 PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR2.2 NATURAL HABITAT BUFFER ZONE *REFER TO LANDSCAPE PLANS *THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 5.6 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. NATURAL HABITAT BUFFER ZONE NOTE IRRIGATION DETAILS 1 WINTERIZATION ASSEMBLY N.T.S.2 BACKFLOW PREVENTION ASSEMBLY N.T.S.3 MASTER VALVE ASSEMBLY N.T.S. M 4 FLOW SENSOR ASSEMBLY N.T.S. F NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 5. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID. 6. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OF VALVE ASSEMBLY. A B C D E F G H IJ K A.30" LENGTH OF COILED WIRE B.FINISH GRADE C.VALVE BOX EXTENSION (HEIGHT AS REQUIRED) D.WIRE SPLICE (REFER TO SPECIFICATIONS E.JUMBO VALVE BOX WITH COVER F.SOLENOID VALVE G.SCH. 80 PVC X HDPE DR11 TRANSITION H.BRICK (1 OF 4) I.FILTER FABRIC J.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL K.PVC SCH 40 MALE ADAPTER L.TRACING WIRE M.HDPE MAINLINE PIPE L 6" MIN.6" MIN. M M G NOTE: 1. FURNISH NOMINAL PIPE AND FITTING SIZES IDENTICAL WITH NOMINAL TAP SIZE UNLESS OTHERWISE NOTED. 2. THIS ASSEMBLY IS INTENDED TO BE USED FOR WINTERIZATION OF BACKFLOW PREVENTION ASSEMBLY, FLOW SENSOR, HYDROMETER AND MASTER VALVE ONLY. A B C D E F G H I JKLM A.JUMBO VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.1/4" THREADED BRASS CAP D.1/2" REDUCING MALE ADAPTER E.1/2" COPPER TYPE K (LENGTH AS REQUIRED) F.6" PVC CL 200 PIPE (LENGTH AS REQUIRED) G.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL H.BRICK (1 OF 4) I.COPPER PIPE TO BACKFLOW PREVENTION ASSEMBLY (LENGTH AS REQUIRED) J.COPPER TEE K.COPPER MALE ADAPTER (1 OF 2) L.CURB STOP VALVE WITH COPPER SERVICE, THREAD BOTH ENDS M.COPPER PIPE TO EXISTING COPPER PIPE OUTSIDE EXISTING WATER METER NOTE: 1. FURNISH FITTINGS AND PIPING SIZED IDENTICALLY WITH NOMINAL BACKFLOW PREVENTION DEVICE. 12" MIN. A B C D E F G A.BACKFLOW PREVENTER ENCLOSURE (SIZE AS NEEDED) B.BACKFLOW PREVENTION DEVICE C.TYPE K COPPER PIPE (TYPICAL) (LENGTH AS REQUIRED) D.WRAP PIPE AT PENETRATION WITH 1/4-INCH FELT OR SLEEVE WITH CLASS 200 PVC E.4-INCH CONCRETE BASE (USE 3000 PSI CONCRETE) F.FINISH GRADE/TOP OF MULCH G.TYPE K COPPER PIPE H.COMPACTED SUBGRADE I.HDPE MAINLINE H I NOTES: 1. ALLOW 10 PIPE DIAMETERS UPSTREAM AND 5 PIPE DIAMETERS DOWNSTREAM OF STRAIGHT RUN OF PIPE TO ACHIEVE PROPER FLOW REGIME. 2. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 3. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 4. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OF SENSOR ASSEMBLY. A B C D E F G H A.12" VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.FLOW SENSOR D.SHIELDED PE-39 COMMUNICATION CABLE TO CONTROLLER E.FILTER FABRIC F.HDPE MAINLINE PIPE G.BRICK (1 OF 4) H.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL I.WIRE SPLICE (REFER TO SPECIFICATIONS) J.SCH. 80 PVC X HDPE DR 11 TRANSITION MIN. 10 x PIPE DIAMATER FROM NEAREST FITTING OR VALVE MINIMUM 5 x PIPE DIAMETER FROM NEAREST FITTING OR VALVE I JJF 5 ISOLATION GATE VALVE ASSEMBLY N.T.S. NOTES: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. 2. CONCRETE SUPPORT BLOCK IS TO BE POURED UNDER ISOLATION GATE VALVE INTENDED TO SUPPORT THE WEIGHT OF THE GATE VALVE. THE ISOLATION GATE VALVE IS NOT TO BE SET IN THE CONCRETE. 3. CONTRACTOR'S OPTION TO INSTALL CINDER BLOCK SUPPORTS IN LIEU OF POURING CONCRETE BLOCK. A B C D E F G I J H A.FINISH GRADE/TOP OF MULCH B.10" VALVE BOX WITH COVER C.6" PVC CL 200 PIPE (LENGTH AS REQUIRED) D.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL E.BRICK (1 OF 2) F.RESILIENT WEDGE GATE VALVE (INTENDED FOR HDPE PIPE) INCLUDING C CLAMPS AND PIPE STIFFENERS G.3 MIL. PLASTIC WRAP WITH TAPED ENDS H.TRACING WIRE I.HDPE MAINLINE PIPE J.CONCRETE SUPPORT BLOCK USE A MINIMUM OF 3 CUBIC FEET OF CONCRETE PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR3.0 IRRIGATION DETAILS 1 BLOW OUT ASSEMBLY N.T.S.2 QUICK COUPLING VALVE ASSEMBLY N.T.S. B Q NOTES: 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 2. INSTALLATION HEIGHT OF QUICK COUPLER VALVE IN VALVE BOX MUST ASSURE PROPER OPERATION OF QUICK COUPLER KEY. A A.HDPE MAINLINE PIPE B.HDPE DR 11 PE4710 TEE C.1-INCH HDPE DR 11 PE4710 PIPE, LENGTH AS REQUIRED D.POLY-CAM MALE THREAD HDPE TRANSITION FITTING, 1-INCH SIZE, HDPE X CARBON STEEL EPOXY COATED MALE THREAD E.BRICK (1 OF 2) F.STANDARD VALVE BOX WITH COVER G.3" MINIMUM DEPTH OF 3/4 " WASHED GRAVEL H.HARCO QUICK COUPLING VALVE ANCHOR I.QUICK COUPLING VALVE J.FINISH GRADE/TOP OF MULCH K.TRACING WIRE E F G H D I J B C K NOTES: 1. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 2. BRAND VALVE BOX LID PER SPECIFICATIONS. A B C D E F G H I JK A.STANDARD VALVE BOX WITH LID B.FINISH GRADE C.GALVANIZED THREADED CAP (SIZE 2-INCH) D.DUCTILE IRON NIPPLE (SIZE 2-INCH) (LENGTH AS REQUIRED) E.CARBON STEEL BALL VALVE (SIZE 2-INCH) F.POLY-CAM MALE THREAD HDPE TRANSITION FITTING, 2-INCH SIZE, HDPE X CARBON STEEL EPOXY COATED MALE THREAD G.TRACING WIRE H.FILTER FABRIC I.BRICKS (CONTINUOUS END TO END AROUND BOTTOM OF VALVE BOX) J.HDPE MAINLINE PIPE K.HDPE DR11 PE4710 TEE 3 REMOTE CONTROL VALVE ASSEMBLY N.T.S. 4 POP UP SPRAY SPRINKLER ASSEMBLY N.T.S. A B C D E F A.FINISH GRADE B.POP-UP SPRAY SPRINKLER C.SWING PIPE, 12" LENGTH D.1/2" MALE NPT x BARB EL E.PVC SCH 40 TEE OR EL F.PVC LATERAL PIPE D NOTES: 1.USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2.NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3.INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4.TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY. 5.DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 6.POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID AND PROPER OPERATION OF BALL VALVE. 7.INSTALL SO THAT NO GRAVEL IS IN CONTACT WITH VALVE ASSEMBLY. 8.COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES. 9.CLEARLY WRITE STATION NUMBER ON DECODER WITH PERMANENT PEN. B D C A.TWO-WIRE CABLE B.HDPE MAINLINE PIPE C.HDPE DR 11 PE4710 TEE D.HDPE DR 11 PE 4710 PIPE, LENGTH AS REQUIRED E.HDPE DR 11 PE 4710 ELBOW F.LASCO HDPE X MPT HEAVY TURF HDPE TRANSITION UNION FITTING G.FINISH GRADE H.JUMBO VALVE BOX WITH LID I.BUTT FUSION BALL VALVE J.WIRES FROM DECODER K.REMOTE CONTROL VALVE L.DECODER M.WIRE SPLICE, TYPICAL (REFER TO SPECIFICATIONS) N.SCH. 40 PVC MALE ADAPTER (MPT X SOC) O.PVC LATERAL PIPE P.3-INCH DEPTH OF 3/4-INCH WASHED GRAVEL Q.FILTER FABRIC R.BRICK (1 OF 4) S.WIRES FROM SOLENOID A E F L M IKNO PQ S J HG R D 6 DRIP REMOTE CONTROL VALVE ASSEMBLY N.T.S. 5 POP UP ROTOR SPRINKLER ASSEMBLY N.T.S. SEE NOTE #1 NOTE: 1. INSTALL SWING JOINT LAY ARM BETWEEN 30° AND 45° OF LATERAL PIPE TO ABSORB DOWNWARD IMPACT. A B C D E A.FINISH GRADE B.POP-UP ROTOR SPRINKLER C.CONTRACTOR FABRICATED SWING JOINT MIPT INLET x MIPT OUTLET D.PVC LATERAL PIPE E.PVC SCH 40 TEE OR EL NOTES: 1.USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2.NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3.INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4.TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY. 5.DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 6.POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID, PROPER OPERATION OF BALL VALVE, AND REMOVAL OF FILTER ELEMENT. 7.INSTALL SO THAT NO GRAVEL IS IN CONTACT WITH VALVE ASSEMBLY. 8.COIL 3-FEET OF WIRE FOR EACH DECODER FOR SERVICE PURPOSES. 9.CLEARLY WRITE STATION NUMBER ON DECODER WITH PERMANENT PEN. B D C A.TWO-WIRE CABLE B.HDPE MAINLINE PIPE C.HDPE DR 11 PE4710 TEE D.HDPE DR 11 PE 4710 PIPE, LENGTH AS REQUIRED E.HDPE DR 11 PE 4710 ELBOW F.LASCO HDPE X MPT HEAVY TURF HDPE TRANSITION UNION FITTING G.JUMBO VALVE BOX WITH LID H.FINISH GRADE I.BUTT FUSION BALL VALVE J.WIRES FROM DECODER K.REMOTE CONTROL VALVE L.DECODER M.WIRE SPLICE, TYPICAL (REFER TO SPECIFICATIONS) N.PRESSURE REGULATED FILTER O.PVC LATERAL PIPE P.3-INCH DEPTH OF 3/4-INCH WASHED GRAVEL Q.FILTER FABRIC R.BRICK (1 OF 4) S.WIRES FROM SOLENOID T.WIRES FROM DECODER A E DF L M IKNO PQ S J GH R G PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR3.1 IRRIGATION DETAILS 1 ZONE CONTROL VALVE ASSEMBLY N.T.S. A B C D E F G H I J K L M N O A.6" ROUND VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.PVC SCH. 40 EL D.PVC BALL VALVE E.PVC SCH. 40 TRANSITION NIPPLE (MIPTxMHT) F.COMPRESSIONxFEMALE HOSE SWIVEL ADAPTER G.DRIP LATERAL PIPING H.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL I.BRICK (1 OF 2) J.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED, 1 OF 2) K.PVC SCH 40 EL L.PVC SCH 40 STREET EL (1 OF 2) M.PVC DRIP MANIFOLD PIPE N.PVC SCH 40 TEE OR EL O.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 2 FLUSH CAP ASSEMBLY N.T.S. 3 EMITTER PLACEMENT DETAIL N.T.S. X X X X X X X X X X X X X A B C D A.DRIP LATERAL PIPE B.EMITTER C.SHRUB (NUMBER AND SIZE OF EMITTERS PER EMITTER SCHEDULE) D.PERENNIAL (NUMBER AND SIZE OF EMITTERS PER EMITTER SCHEDULE) EMITTER SCHEDULE PLANT EMITTERS GPH PER TOTAL GPH TYPE PER PLANT OUTLET PER PLANT 5 GAL. LOW SHRUBS 2 SINGLE 1 GPH 2 GPH 1 GAL. LOW SHRUBS 2 SINGLE 1/2 GPH 1 GPH 1 GAL. LOW GROUND 2 SINGLE 1/2 GPH 1 GPH COVER/PERENNIAL 5 GAL. MEDIUM SHRUBS 2 SINGLE 2 GPH 4 GPH 1 GAL. MEDIUM SHRUBS 2 SINGLE 1 GPH 2 GPH 1 GAL. MEDIUM GROUND 2 SINGLE 1 GPH 2 GPH COVER/PERENNIAL NOTE: 1.ALL EMISSION POINTS TO BE LOCATED ON THE UPHILL SIDE OF PLANT MATERIAL. 2.PLACE EMITTERS AT A LOCATION TO NOT SATURATE PLANT ROOTS, LOCATE EMITTERS JUST OFF THE EDGE OF THE ROOT BALL. 3.REVIEW PLANT MATERIAL HEALTH 1 MONTH AFTER INSTALLATION AND ADJUST EMITTER SIZE AND QUANTITY PER CITY FORESTRY DIRECTION. X X X X X NOTE: 1. INSTALL FLUSH CAP ASSEMBLY AT THE END OF EACH DRIP LATERAL SEGMENT. A BC D E F A.FINISH GRADE/TOP OF MULCH B.6" ROUND VALVE BOX WITH COVER C.FLUSH CAP WITH HOSE THREAD CAP D.DRIP IRRIGATION LATERAL E.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL F.BRICK (1 OF 2) G.90° INSERT FITTING H.PINCH CLAMP (1 OF 2) G H 5 TREE/SHRUB RING ASSEMBLY N.T.S. NOTE: 1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN TURF AND NATIVE AREAS 2-3" BELOW GRADE. 2. DIAMETER OF DRIPLINE RINGS ARE DEPENDANT ON TREE CANOPY SIZE. 3. CONTRACTOR SHALL CUT DRIP TUBING AT POINT "X" AND INSTALL FLUSH CAP AS TRUNK DIAMETER INCREASES. 4. APPROXIMATE FLOW PER ASSEMBLY IS 0.23 GPM FOR THE 2-RING ASSEMBLY AND .43 GPM FOR THE 3-RING ASSEMBLY. A B C D E F A.DRIP LATERAL PIPE B.3/4" POLYETHYLENE TUBING: RAIN BIRD XBS BLACK STRIPE PIPE C.EASY FIT COMPRESSION TEE: RAIN BIRD MDCFTEE (QTY AS REQUIRED) D.EASY FIT REMOVABLE FLUSH CAP: RAIN BIRD MDCFCAP (QTY AS REQUIRED) E.LANDSCAPE DRIPLINE TUBING: RAIN BIRD DRIPLINE MODEL XFCV-06-12 (0.6 GPH/EMITTER) F.TIE DOWN STAKE: RAIN BIRD TDS-050 W/BEND (QTY AS REQUIRED) G.TREE/SHRUB ROOTBALL H.EASY FIT COMPRESSION ELBOW RAIN BIRD MDCFEL (QTY AS REQUIRED) G H 1' FROM TRUNK 1' A F D C G H E B 1' FROM TRUNK 1'1' A B C D G 1' FROM TRUNK E F SHRUB 4 IRRIGATION CONTROLLER ASSEMBLY N.T.S. A A B C DE A.IRRIGATION CONTROLLER INDOOR WALL MOUNT B.2" PVC SCH 40 CONDUIT AND FITTINGS C.JUNCTION BOX D.TWO WIRE CABLES TO REMOTE CONTROL VALVES E.1" PVC SCH 40 CONDUIT AND FITTINGS TO POWER SUPPLY WALL PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR3.2 NOTE: 1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN TURF AND NATIVE AREAS 2-3" BELOW GRADE. 2. APPROXIMATE FLOW PER ASSEMBLY IS 0.97 GPM. A.DRIP LATERAL PIPE B.3/4" POLYETHYLENE TUBING: RAIN BIRD XBS BLACK STRIPE PIPE C.EASY FIT COMPRESSION TEE: RAIN BIRD MDCFTEE (QTY AS REQUIRED) D.EASY FIT REMOVABLE FLUSH CAP: RAIN BIRD MDCFCAP (QTY AS REQUIRED) E.LANDSCAPE DRIPLINE TUBING: RAIN BIRD DRIPLINE MODEL XFCV-06-12 (0.6 GPH/EMITTER) F.TIE DOWN STAKE: RAIN BIRD TDS-050 W/BEND (QTY AS REQUIRED) G.TREE ROOTBALL H.EASY FIT COMPRESSION ELBOW RAIN BIRD MDCFEL (QTY AS REQUIRED) A F D C G H E B 1' FROM TRUNK 1'1'1'1' 6 10' DIAMETER TREE RING ASSEMBLY N.T.S. T LT IRRIGATION DETAILS 3 WIRE SPLICE DETAIL N.T.S.2 TWO WIRE GROUNDING DETAIL N.T.S.1 IRRIGATION CONTROLLER GROUNDING DETAIL N.T.S. PLAN VIEW A.IRRIGATION CONTROLLER ASSEMBLY B.UL LISTED 5/8" X 10' COPPER-CLAD GROUNDING ROD C.UL LISTED 4" X 8' COPPER GROUNDING PLATE D.10" ROUND VALVE BOX WITH COVER E.BRONZE GROUND ROD CLAMP OR CADWELD CONNECTION: PAIGE ELECTRIC F.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL G.BRICK (1 OF 4) H.#6 AWG INSULATED SOLID COPPER WIRE. NO SHARP BENDS. I.SPHERE OF INFLUENCE J.EARTH CONTACT MATERIAL, POWERSET© OR POWERFILL© DEPENDING ON SOIL CONDITIONS K.FINISH GRADE A C B 8' 10' 11' I I 30" MINIMUM 12" SECTION VIEW H H H B C J D G F E NOTES: 1.CONNECT ALL #6 AWG WIRES INSIDE THE CONTROLLER. CONNECT ONE WIRE TO THE CONTROLLER GROUND LUG AND USE A #4 SPLIT BOLT TO CONNECT ALL WIRES TOGETHER. 2.EARTH CONTACT MATERIAL MUST COMPLETELY COVER THE WELD JOINT ON THE GROUND PLATE. K 1. 2. 3.4. 1/2" 5. NOTE: 1. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS". 1. STRIP ENDS OF WIRE 2. SECURE WIRES INTO WIRE NUT 3. INSERT WIRE NUT INTO GEL-FILLED TUBE 4. POSITION WIRES INTO CHANNELS 5. CLOSE SPLICE KIT FOR SECURED SEAL A A.TWO-WIRE CABLE B.VALVE BOX (10" ROUND OR AS NECESSARY) C.REMOTE CONTROL VALVE D.5/8" X 8' U.L. LISTED GROUND ROD E.DECODER F.LINE SURGE PROTECTOR G.BARE AWG #10 COPPER WIRE H.S-6 SPLIT BOLT I.BARE COPPER CONNECTION ("CADWELD") J.REMOTE CONTROL VALVE ASSEMBLY 500' MAX OR 5 DECODERS BETWEEN GROUND POINTS WHICHEVER IS FIRST GROUND ALL DEAD ENDS 25' AND LONGER SPHERE OF INFLUENCE WIRE PATH OUTSIDE SPHERE OF INFLUENCE (8-10')GROUND TWO WIRE CABLE NEAR CONTROLLER PER MANUFACTURER'S GUIDELINES NOTES: 1. ALL WIRE CONNECTION SHALL BE MADE WITH APPROVED CONNECTORS. 2. MAKE ALL WIRE SPLICES IN VALVE BOXES. 3. LEAVE A MINIMUM OF 36" EXTRA WIRE AT ALL SPLICE POINTS. 4. TEST EARTH TO GROUND RESISTANCE AT ALL GROUND POINTS. 5. EARTH TO GROUND RESISTANCE MUST MEET OR EXCEED MANUFACTURER REQUIREMENTS. 6. INSTALL ALL GROUND ASSEMBLIES IN VALVE BOXES. 7. INSTALL GROUNDING EQUIPMENT AS INDICATED ON THE IRRIGATION DOCUMENTS AND AS RECOMMENDED BY THE MANUFACTURER. C D A JB E G H F I B 4 TRACING WIRE DETAIL N.T.S.5 TRENCH DETAIL N.T.S. 6 SLEEVE DETAIL N.T.S. 12" MINIMUM 24" 24" 14" NOTE: 1. INSTALL SLEEVE SO THAT ITS LOWEST ELEVATION OCCURS AT ONE OR BOTH ENDS - NOT ALONG ITS LENGTH. A B C D A.FINISHED GRADE OF PAVED SURFACE B.SLEEVE FOR LATERAL PIPE C.SLEEVE FOR MAINLINE PIPE D.SLEEVE FOR TWO WIRE CABLE MARK SLEEVE LOVATION IN CONCRETE WITH 3" "X", 1" OFFSET FROM CONCRETE EDGE FINISHED GRADE ELEVATION VIEW PLAN VIEW NOTES: 1. COPPER TRACING WIRE WILL START AT THE MASTER VALVE AND WILL BE ROUTED WITH ALL MAINLINE PIPE. 2. SPLICE TRACING WIRE IN IRRIGATION MAINLINE COMPONENT VALVE BOXES WHEN POSSIBLE, OTHERWISE, PLACE SPLICE IN SEPARATE VALVE BOX. B C D EF G H A.10" ROUND VALVE BOX (ONE OF TWO) B.INSTALL TRACING WIRE TO THE TOP OF VALVE BOX C.WATER PROOF CONNECTION (SEE SPECIFICATIONS) D.PIPE SLEEVE SEE VALVE DETAIL E.TAPE COPPER WIRE TO TOP OF PIPE EVERY 10 FT. F.CONTINUOUS LOOP COPPER TRACING WIRE (SEE SPECIFICATIONS) G.PVC PIPE H.TYP. VALVE A NOTE: 1. REFER TO IRRIGATION SPECIFICATIONS FOR COVERAGE DEPTH TO BURIED PIPE AND WIRE. A B C D F G A.WARNING TAPE B.FINISH GRADE C.BACKFILL D.LATERAL PIPE E.TRACING WIRE F.TWO-WIRE CABLE G.MAINLINE PIPE H.SPARE TWO-WIRE CABLE E H PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR3.3 IRRIGATION DETAILS 1 HYDRAULIC ESTIMATION N.T.S.2 ANNUAL WATER USE CHART N.T.S. NOTES: 1.THE TAP AND METER SIZE WAS CHOSEN TO IRRIGATE THE TURF. ANY SEED IRRIGATION WOULD REQUIRE A LONGER IRRIGATION WINDOW. 2.THE TAP/METER SIZE ALLOWS TURF AREAS TO BE IRRIGATED WITHIN A 6 HOUR PER DAY X 6 DAY PER WEEK IRRIGATION WINDOW. 3.THE TAP/METER SIZE ALLOWS SEED AREAS TO BE IRRIGATED WITHIN A 14 HOUR PER DAY X 6 DAY PER WEEK IRRIGATION WINDOW. 4.IRRIGATION FOR SEED IS INTENDED AS ESTABLISHMENT ONLY. AFTER ESTABLISHMENT ALL SEED ZONES TO BE SHUT DOWN PERMANENTLY. 3 IRRIGATION CONTROLLER PEAK SCHEDULE N.T.S. NOTES: 1. THE PEAK SEASON RUN TIME HAS BEEN CALCULATED ASSUMING AN IRRIGATION EFFICIENCY OF 70% AND A PEAK SEASON ETo OF 0.21 INCHES/DAY. THE CROP COEFFICIENT IS ASSUMED TO BE 0.8 FOR TURF AND 0.6 FOR SEED. 2. THE POC SIZE WAS CALCULATED FOR A 8 HR X 6 DAYS/WEEK IRRIGATION WINDOW TO IRRIGATE THE TURF GRASS AND SEED. 3. ADJUST INDIVIDUAL STATION RUN TIMES AS NECESSARY TO ACCOMMODATE TURF/PLANT ESTABLISHMENT, TURF TYPE, TURF/PLANT SOLAR EXPOSURE, SOIL TYPES, WIND, AND SLOPE. 4. ADJUST DRIP RUN TIMES AS NECESSARY FOR PLANT ESTABLISHMENT. RECORD RUN TIMES ON THE RECORD DRAWINGS. 5. BLANK ITEMS TO BE COMPLETED ON AS-BUILT DRAWINGS BY CONTRACTOR. SOIL TYPE - CLAY, SAND, LOAM, ETC. SLOPE - NONE, GENTLE, MILD, STEEP. MICROCLIMATE - SHADE, PARTIAL SUN/SHADE, FULL SUN. 6. PROVIDE LAMINATED COPY OF PEAK IRRIGATION SCHEDULE WITHIN IRRIGATION CONTROLLER ENCLOSURE. PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS : SCALE: SHEET TITLE: ISSUED FOR: APPROVED: 270702026 OCTOBER 23, 2024 SCHOOLSIDE PARK FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2 BUSINESS DAYS IN ADVANCE IN METRO DENVER 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATION MEMBER UTILITIES 534-6700OR Park Planning & Development City of 215 North Mason Street Fort Collins, Colorado 80521 tel: 970.221.6360 www.fcgov.com/parkplanning/ Park Planning & Development JHK RWB RWB CI T Y O F F O R T C O L L I N S FO R T C O L L I N S , C O L O R A D O SC H O O L S I D E P A R K BA S I C D E V E L O P M E N T R E V I E W S U B M I T T A L BDR SUBMITTAL IR3.4