HomeMy WebLinkAboutRIDGEWOOD HILLS - FDP230019 - SUBMITTAL DOCUMENTS - ROUND 3 - Irrigation PlansM
QC
MV
FS
M
M
QC
MV
FS
MD
MD
QC
QC
QC
QC
QC
MV
FS
MD
QC
QC
QC
QC
QC
QC
QC
QC
CONTROLLERC
WS
CONTROLLERB
WS
CONTROLLERA
WS
QC
QC
QC
QC
QC
QC
QC
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
SPSP
SP
SP
SP
SP
SP
SP SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
OVERALL IRRIGATION
MAINLINE PLAN
IR-100
SCALE: 1"=100'
0 50 10020
JR
EDN
IR-102
IR-103 IR-104
IR-105 IR-106 IR-107
IR-108 IR-109
IR-111IR-110
IR-113IR-112
WIRING/SLEEVING NOTES
IRRIGATION DISCLAIMER
1.IRRIGATION DESIGN IS NOT AN EXACT SCIENCE. IT IS BASED ON THEORIES,
ASSUMPTIONS, AND/OR INFORMATION PROVIDED BY CIVIL
MODELS/UTILITIES/MUNICIPALITIES ENTITIES AND THUS DIAGRAMMATIC IN
NATURE.
2.CONTRACTOR SHALL INSTALL MAINLINES ±12" FROM PAVEMENT EDGE IN
PLANTING AREAS. ALL PIPING, VALVES, AND OTHER EQUIPMENT SHOWN
WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN
CLARIFICATION ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN
THE PROPERTY LINES OR LIMITS AS INDICATED ON THESE PLANS.
3.THE IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL
ABOVE-GRADE AND VISIBLE IRRIGATION EQUIPMENT (CONTROLLERS,
BACKFLOW PREVENTERS, METER PITS, ETC.) WITH THE OWNER'S
AUTHORIZED REPRESENTATIVE AND / OR LANDSCAPE ARCHITECT PRIOR TO
INSTALLATION. THE INSTALLATION OF THESE ITEMS SHALL BE INTEGRATED
WITHIN DESIGNATED LANDSCAPE AREAS. FAILURE TO LOCATE THIS
EQUIPMENT IN AN APPROVED LOCATION MAY RESULT IN THE IRRIGATION
CONTRACTOR BEING REQUIRED TO MOVE SUCH ITEMS AT HIS OWN COST.
4.THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING
PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE DRAWINGS.
THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE STATIC &
OPERATING WATER PRESSURE PRIOR TO CONSTRUCTION OF ANY
COMPONENT OF THE IRRIGATION SYSTEM. AFTER FIELD VERIFICATION, THE
IRRIGATION CONTRACTOR SHALL NOTIFY THE OWNER, OWNER'S
REPRESENTATIVE, LANDSCAPE ARCHITECT, & IRRIGATION DESIGNER OF
THE PRESSURE READING FOR THE TAP.
5.ALL PRESSURIZED MAINLINES, VALVES, DRIP, AND ROTOR AND SPRAY
HEADS SHALL BE INSTALLED A MINIMUM OF 5' AWAY FROM ANY BUILDING
FOUNDATION. ADDITIONAL REQUIREMENTS MAY BE LISTED IN THE
GEOTECHNICAL REPORT REGARDING IRRIGATION NEAR BUILDING
FOUNDATIONS. CONTRACTOR IS RESPONSIBLE TO ABIDE BY THE 5' MINIMUM
DISTANCE AND/OR THE GEOTECHNICAL REPORT REQUIREMENTS. IF THIS
EQUIPMENT IS SHOWN WITHIN THE 5' OFFSET ON THESE PLANS, IT IS FOR
THE PURPOSE OF GRAPHIC CLARITY ONLY.
6.REFER TO SHEET IR-100 FOR IRRIGATION NOTES, IR-114, & IR-115 FOR
IRRIGATION DETAILS.
1.THE LANDSCAPE CONTRACTOR IS REQUIRED TO CONTACT THE COUNTY
PUBLIC WORKS DEPARTMENT, AND ANY OTHER PUBLIC OR PRIVATE
AGENCY NECESSARY FOR UTILITY LOCATION PRIOR TO ANY
CONSTRUCTION.
2.THIS DRAWING IS A PART OF A COMPLETE SET OF BID DOCUMENTS,
SPECIFICATIONS, ADDITIONAL DRAWINGS, AND EXHIBITS. UNDER NO
CIRCUMSTANCES SHOULD THESE PLANS BE USED FOR CONSTRUCTION
PURPOSES WITHOUT EXAMINING ACTUAL LOCATIONS OF UTILITIES ON
SITE, AND REVIEWING ALL RELATED DOCUMENTS.
3.THE LOCATION OF THE ALL UNDERGROUND UTILITIES ARE LOCATED ON
THE ENGINEERING DRAWINGS FOR THIS PROJECT. THE MOST CURRENT
REVISION IS HERE IN MADE PART OF THIS DOCUMENT. UNDERGROUND
UTILITIES EXIST THROUGHOUT THIS SITE AND MUST BE LOCATED PRIOR
TO ANY CONSTRUCTION ACTIVITY. WHERE UNDERGROUND UTILITIES
EXIST, FIELD ADJUSTMENT MAY BE NECESSARY AND MUST BE
APPROVED BY A REPRESENTATIVE OF THE OWNER. NEITHER THE
OWNER NOR THE LANDSCAPE ARCHITECT ASSUMES ANY
RESPONSIBILITY WHATSOEVER, IN RESPECT TO THE CONTRACTORS
ACCURACY IN LOCATING THE INDICATED PLANT MATERIAL, AND UNDER
NO CIRCUMSTANCES SHOULD THESE PLANS BE USED WITHOUT
REFERENCING THE ABOVE MENTIONED DOCUMENTS.
IN ADDITION TO PROVIDING SLEEVES FOR ALL PIPING UNDER ROADWAYS AND
WALKWAYS, PROVIDE AND INSTALL SCH. 40 PVC SLEEVES FOR ALL
CONTROLLER WIRES OCCURRING UNDER ALL ROADWAYS AND WALKWAYS.
SLEEVES FOR CONTROLLER WIRES SHALL BE 2" DIA. AND CONTAIN NO MORE
THAN 25 WIRES.
UTILITY NOTES
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
IR1.1 KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR1.2
IR1.3 IR1.4
IR1.6 IR1.7IR1.5
IR1.9IR1.8
IR1.11IR1.10
IR1.13IR1.12
GENERAL IRRIGATION NOTES
1.IRRIGATION DESIGN IS BASED ON THEORIES, ASSUMPTIONS, AND/OR INFORMATION PROVIDED BY CIVIL
MODELS/UTILITIES/MUNICIPAL ENTITIES AND THUS, IS DIAGRAMMATIC IN NATURE. ALL PIPING, VALVES, AND OTHER
EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR GRAPHIC CLARIFICATION ONLY,
AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS INDICATED ON PLAN. THE
IRRIGATION CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL ABOVE-GRADE IRRIGATION EQUIPMENT WITH THE
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION, OR IRRIGATION CONTRACTOR MAY BE REQUIRED TO
MOVE SUCH ITEMS AT HIS OWN COST.
2. REFER TO SPECIFICATIONS (AS APPROPRIATE) FOR SUBMITTALS, INSPECTIONS AND OTHER APPLICABLE INFORMATION.
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A COPY OF THE PROJECT SPECIFICATIONS PRIOR TO BIDDING. THE
PROJECT SPECIFICATIONS ARE A PART OF THESE PLANS AND SHALL BE CONSULTED BY THE IRRIGATION CONTRACTOR.
THE CONTRACTOR IS RESPONSIBLE FOR IMPLEMENTING WORK AS SPECIFIED IN THE PROJECT SPECIFICATIONS AND ON
THE PLANS.
3.THE IRRIGATION CONTRACTOR SHALL MEET WITH THE OWNER'S REPRESENTATIVE PRIOR TO COMMENCEMENT OF WORK,
AND SHALL OBTAIN ALL ENGINEERING, LANDSCAPE, AND OTHER APPLICABLE PLANS & DOCUMENTS. CONTRACTOR
SHALL THOROUGHLY REVIEW PLANS & REPORT ANY CONFLICTS OR DISCREPANCIES TO OWNER'S REPRESENTATIVE
IMMEDIATELY.
4.CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, EQUIPMENT QUANTITIES, AND UTILITY LOCATIONS PRIOR TO
BEGINNING WORK. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE
FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT
HAVE EXISTED AT THE TIME OF THE IRRIGATION DESIGN PREPARATION. SUCH OBSTRUCTIONS OR DIFFERENCES SHALL
BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE AND LANDSCAPE
ARCHITECT. IN THE EVENT THIS NOTIFICATION IS NOT GIVEN, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL
RESPONSIBILITY FOR ANY REVISIONS NECESSARY TO BRING THE SYSTEM TO A PROPER WORKING CONDITION, AND TO
THE OWNER'S SATISFACTION.
5.IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES,
LOCATIONS OF WALLS, RETAINING WALLS, ETC. THE IRRIGATION CONTRACTOR SHALL COORDINATE HIS WORK WITH THE
GENERAL CONTRACTOR AND OTHER SUBCONTRACTORS FOR THE LOCATION AND INSTALLATION OF PIPE SLEEVES
THROUGH WALL, UNDER ROADWAY PAVING, ETC.
6.THE CONTRACTOR SHALL MAKE NO SUBSTITUTIONS, DELETIONS, OR ADDITIONS TO THIS PLAN WITHOUT APPROVAL OF
THE LANDSCAPE ARCHITECT.
7.SEE CIVIL ENGINEER'S DRAWINGS FOR IRRIGATION POINT OF CONNECTION (TAP) AND DOMESTIC WATER SUPPLY.
8.ALL CONSTRUCTION SHALL CONFORM TO CITY, COUNTY, STATE, AND FEDERAL REQUIREMENTS. IT SHALL BE THE
RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO ENSURE THAT ALL IRRIGATION EQUIPMENT MEETS GOVERNMENT
REGULATIONS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR OBTAINING ANY NECESSARY PERMITS OR APPROVALS
9.THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND
SHOWN ON THE POINT OF CONNECTION NOTE TAG(S) ON THE DRAWINGS. THE IRRIGATION CONTRACTOR SHALL FIELD
VERIFY THE STATIC & OPERATING WATER PRESSURE PRIOR TO CONSTRUCTION, AND SHALL REPORT ANY DIFFERENCES
BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE
IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE AND LANDSCAPE ARCHITECT. IN
THE EVENT PRESSURE DIFFERENCES ARE NOT REPORTED OR PRESSURES HAVE GREATLY CHANGED PRIOR TO THE
START OF THE IRRIGATION SYSTEM CONSTRUCTION, THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR
RECOMMENDING A SOLUTION AND PROVIDING AN ADD ALTERNATE BID FOR IRRIGATION COSTS.
10.CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IF AVAILABLE WATER PRESSURE EXCEEDS 5 PSI HIGHER OR
LOWER THAN AVAILABLE WATER PRESSURE.
11.NO MORE THAN 90% OF AVAILABLE MINIMUM STATIC WATER PRESSURE WAS USED IN PREPARATION OF THESE PLANS,
FURTHERMORE, THE MAXIMUM FLOW THROUGH THE METER SHOULD NOT EXCEED 75% OF THE MAXIMUM SAFE FLOW.
12.SUPPLY LINE AND METER TO BE PROVIDED BY GENERAL CONTRACTOR. BACKFLOW PREVENTER TO BE PROVIDED BY
IRRIGATION CONTRACTOR. IRRIGATION CONTRACTOR'S POINT OF CONNECTION TO BEGIN AFTER THE IRRIGATION
WATER METER.
13.INSTALL ALL MATERIALS AND EQUIPMENT AS SHOWN ON THE PLANS AND DETAILS. NO SUBSTITUTIONS OF EQUIPMENT
WILL BE ACCEPTABLE WITHOUT PRIOR WRITTEN APPROVAL BY THE LANDSCAPE ARCHITECT OR THE OWNERS
REPRESENTATIVE. THE IRRIGATION CONTRACTOR MAY BE REQUIRED TO REMOVE AND REPLACE ALL UNAPPROVED
SUBSTITUTED EQUIPMENT AT HIS OWN COST IF SO DIRECTED BY THE OWNER.
14.WHEN INSTALLING IRRIGATION PIPE AND EQUIPMENT NEXT TO HARDSCAPE (SUCH AS WALLS, CURBS, OR WALKS), PLACE
PIPE AS CLOSE AS POSSIBLE TO HARDSCAPE TO AVOID CONFLICTS WITH PLANTING. REFER TO MAINLINE TRENCHING
DETAILS FOR ADDITIONAL INFORMATION.
15.THE IRRIGATION CONTRACTOR SHALL COORDINATE 120 V.A.C. ELECTRICAL POWER TO CONTROLLERS AND DEDICATE
ONE (1) 20-AMP BREAKER FOR EACH CONTROLLER. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR
TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL SOURCE TO THE CONTROLLER UNIT ONLY.
16.THE RAIN SENSOR SHALL BE LOCATED NEAR THE IRRIGATION CONTROLLER, AND SHALL BE MOUNTED AS SHOWN ON THE
DETAIL AND/OR LEGEND. LOCATE SENSOR AWAY FROM TALL TREES, SHRUBS, AND OTHER POTENTIAL OBSTRUCTIONS.
17.ALL VALVE CONTROL WIRE SHALL BE AWG 14 TYPE UF, 600 VOLT TEST, DIRECT BURIAL. NO SPLICES SHALL BE ALLOWED
EXCEPT AT VALVES AND CONTROLLER. WHERE SPLICES MAY BE NECESSARY DUE TO EXCESSIVELY LONG WIRE RUNS,
THE CONTRACTOR SHALL MAKE ALL SPLICES IN 6" ROUND VALVE BOXES WITH 3M'S "DBY-DIRECT BURIAL SPLICE KIT".
THE CONTRACTOR SHALL LABEL ALL WIRES WITH WATERPROOF TAGS AND MARKERS AT ALL SPLICES AND VALVE
MANIFOLDS, AND SHALL LEAVE A 24" COIL OF EXCESS WIRE AT EACH CONNECTION.
18.CONTRACTOR SHALL PROVIDE #10 COMMON WIRE, DIRECT BURIAL, TO ALL REMOTE CONTROL VALVES.
19.CONNECT ALL DIRECT BURIAL WIRES TO VALVES USING 3M'S "DBY-DIRECT BURIAL SPLICE KIT" (UNLESS OTHERWISE
SPECIFIED).
20.PROVIDE ADDITIONAL IRRIGATION CONTROL WIRES TO THE AMOUNT OF OPEN ZONES ON THE CONTROLLER ALONG EACH
BRANCH OF MAINLINE FOR FUTURE EXPANSION. STUB ADDITIONAL CONTROL WIRES INTO BACK OF IRRIGATION
CONTROLLERS.
21.THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL CONTROL WIRE SLEEVES AND PIPE
SLEEVES UNDER PAVED AREAS PRIOR TO PAVING. ELECTRICAL WIRES FOR IRRIGATION VALVES AND IRRIGATION LINES
ARE TO BE PLACED IN SEPARATE SLEEVES. ALL SLEEVING SHALL BE PVC SCHEDULE 40 PIPE. SLEEVES FOR MAINLINE
AND LATERAL LINES SHALL BE A MINIMUM TWICE THE DIAMETER OF THE ENCLOSED PIPE; SLEEVES FOR CONTROL WIRES
SHALL BE AS PER THE SLEEVING / WIRING NOTE AND THE WIRING SLEEVE LEGEND ITEM AS SHOWN ON THESE DRAWINGS.
22.TRENCH BACKFILL MATERIAL SHALL BE FREE OF ROCKS, GLASS, AND OTHER EXTRANEOUS MATERIALS LARGER THAN 1"
IN DIAMETER. BACKFILL SHALL BE COMPACTED TO 90% MAXIMUM DRY DENSITY.
23.WHERE VALVES ARE LOCATED IN CLOSE PROXIMITY TO EACH OTHER, CLUSTER VALVES INTO MANIFOLDS. INSTALL NO
MORE THAN ONE VALVE PER VALVE BOX.
24.MANUAL DRAIN VALVE, FOR FREEZE PROTECTION, ARE TO BE LOCATED AT ALL LOW POINTS OF IRRIGATION LATERAL
LINES. WHERE THE LOW POINT IS AT THE END OF THE LINE, LOCATE DRAIN VALVE A MINIMUM OF 12" DOWNSTREAM FROM
THE LAST SPRINKLER HEAD. SEE DETAIL FOR VALVE ORIENTATION.
25.USE TEFLON TAPE ON ALL PVC MALE PIPE THREADS ON ALL SWING JOINT AND VALVE ASSEMBLIES.
26.ALL IRRIGATION HEADS, INCLUDING FIXED-SPRAY AND DRIP DEVICES, SHALL BE SET PERPENDICULAR TO THE FINISH
GRADE OF THE AREA TO BE IRRIGATED.
27.ALL PRESSURIZED MAINLINES, VALVES, DRIP, AND ROTOR AND SPRAY HEADS SHALL BE INSTALLED A MINIMUM OF 3'
AWAY FROM ANY BUILDING FOUNDATION. IF THIS EQUIPMENT IS SHOWN WITHIN THE 3' OFFSET ON THESE PLANS, IT IS
FOR THE PURPOSE OF GRAPHIC CLARITY ONLY.
28.EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE, IT IS THE INTENT OF THE IRRIGATION DESIGN TO INDICATE ALL SPRAY
HEADS AS "POP-UPS". IN THE EVENT THAT POP-UP HEADS HAVE NOT BEEN SPECIFIED IN TURF AREAS, IT SHALL BE THE
RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BRING THIS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT
PRIOR TO BIDDING AND CONSTRUCTION.
29.ALL SPRAY AND ROTOR HEAD LOCATIONS SHALL BE STAKED, FLAGGED AND/OR OTHERWISE CLEARLY MARKED ON THE
GROUND PRIOR TO INSTALLATION. SPRINKLER HEAD STAKING SHALL BE INSPECTED AND APPROVED BY THE OWNER'S
REPRESENTATIVE OR THE LANDSCAPE ARCHITECT BEFORE INSTALLATION. STAKED LOCATIONS SHALL BE SPACED TO
PROVIDE HEAD-TO-HEAD COVERAGE. RECOMMENDED SETBACK DISTANCE OF ALL PROPOSED IRRIGATION HEADS IS 12"
FROM BACK OF CURB AND EDGE OF PAVEMENT.
30.FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS,
ROADWAYS, AND/OR BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST NOZZLE ARC AND
RADIUS TO FIT THE EXISTING SITE CONDITIONS.
31.ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN TURF AREAS SHALL BE INSTALLED SO THE TOP OF THE SPRINKLER
HEAD IS FLUSH WITH THE ADJACENT SIDEWALK, OR PAVING. ALL POP-UP HEADS AWAY FROM HARDSCAPE EDGES IN
TURF SHALL BE 1" ABOVE THE FINISH GRADE TO PREVENT CONTACT WITH MOWERS.
32.EXISTING TREES TO REMAIN ARE TO BE PROTECTED FROM DAMAGE. DO NOT TRENCH OR EXCAVATE WITHIN THE
CRITICAL ROOT ZONE OF ANY TREE.
33.ALL PLANT MATERIAL IN TREE HOLDING AREAS SHALL BE MANUALLY WATERED/IRRIGATED TO KEEP MOIST UNTIL
PLANTED.
34.UPON COMPLETION OF INSTALLATION OF IRRIGATION SYSTEM, IRRIGATION CONTRACTOR SHALL PROVIDE THE
FOLLOWING:
A. ACCURATE AND COMPLETE "AS BUILT" PLANS OF IRRIGATION SYSTEM INCLUDING 8-1/2" X 11" ZONE MAP TO BE
PLACED INSIDE EACH CONTROLLER BOX.
B. LOG ON ALL WATER WINDOWS, RUN SCHEDULE TIMES, AND OTHER CHANGES AND/OR MODIFICATIONS TO THE
IRRIGATION SYSTEM SINCE INSTALLATION.
C. ONE HOUR OF TRAINING TO OWNER ON IRRIGATION SYSTEM AND CONTROLLER OPERATION.
D. THREE OF EACH TYPE OF HEAD AND EMITTER INSTALLED.
E. ONE OF EACH TYPE OF VALVE INSTALLED.
F. REVIEW WINTERIZATION PROCEDURES FOR IRRIGATION SYSTEM WITH OWNERS REPRESENTATIVE.
35.PRIOR TO ACCEPTANCE OF IRRIGATION SYSTEM AT THE END OF THE MAINTENANCE PERIOD, THE IRRIGATION
CONTRACTOR SHALL PROVIDE THE FOLLOWING: CURRENT SCHEDULE RUN TIME AND WATER WINDOW LOG, ALONG WITH
NOTING ANY OTHER PERTINENT INFORMATION.
36.UNLESS OTHERWISE SPECIFIED, THE IRRIGATION CONTRACTOR SHALL REPAIR OR REPLACE ANYTHING DAMAGED BY HIS
WORK AT NO ADDITIONAL COST TO THE OWNER.
37.CONTRACTOR SHALL INSTALL MAINLINES ±12" FROM PAVEMENT EDGE IN PLANTING AREAS. ALL PIPING, VALVES, AND
OTHER EQUIPMENT SHOWN WITHIN PAVED AREAS OR OUT OF PROPERTY BOUNDARIES ARE FOR DESIGN CLARIFICATION
ONLY, AND SHALL BE INSTALLED IN PLANTING AREAS WITHIN THE PROPERTY LINES OR LIMITS AS INDICATED ON THESE
PLANS.
38.IN THE EVENT OF A DISCREPANCY BETWEEN THE PLAN AND SPECIFICATIONS, THE PLAN SHALL TAKE PRECEDENCE.
39.THE IRRIGATION SYSTEM SHALL BE INSTALLED BY A QUALIFIED IRRIGATION CONTRACTOR.
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ THIRTY-SIX (36) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'C' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 2"
POINT OF CONNECTION 'C'
▪ USE 2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" & 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ FOURTEEN (14) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'B' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 1-1/2"
POINT OF CONNECTION 'B'
▪ USE 1-1/2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" OR 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ THIRTY-SIX (36) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'A' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 1-1/2"
POINT OF CONNECTION 'A'
▪ USE 1-1/2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" & 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
IR-101
S
UE
UE
UE
UE
T
T
E
E
E
MV
MV
R
S
S
S
S
S
K
K
K
K
K
K
K
K
K
K
K
K
K
M
M
M
M
M
M
M
M
O
O
O
L
S
S
M
M
L
L
M
M
L
M
M
M
M
M
M
M
L
M
M
M
M
M
M
M
M
M
1"
1"
3 4"
A5
A6
1"7.8
A7
1"6.38
A8
1"5.54
FV
FV FV
FV
FV
FV
FV
SP
SP
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-101
SCALE: 1"=20'
0 10 20
MATCHLINE-SEE SHEET IR-103
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
2
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
M M
M
M
M
M
M
M
3 4"
3 4"
A9
1"3.71
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-102
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
1
MATCHLINE-SEE SHEET IR-104
JR
EDN
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UEE
UE
MV
MV
S
S
S
S
S
S
S
S
S
S
S
S
S
L
R
S
S
S
S
L
K
K
K
K
K
K
K
K
K
K
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
O
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
R
L
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
R
S
S
S
S
S
S
S
S
S
S
B
B
M
QC
MV
FS
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
L
M
M
M
L
L
M
M
M
L
M
O
MD
QC
CONTROLLERA
WS
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
A2
1"11.4
A3
1"7.48
A4
1"13.4
A5
1"12.8
A28
A29
1"13.6
A30
1"10.1
A31
1"7.04
A1
1"14.5
A35
1"14.4
A36
1"7.48
A37
1"11.0
A38
1"11.4
A39
1"2.2
1"112"
3 4"
112"
1"
1"
FV
FV
FV
FV
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER MP STRIP PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. LST=IVORY LEFT STRIP, SST=BROWN SIDE
STRIP, RST=COPPER RIGHT STRIP ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP1000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,
O=OLIVE 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. K=BLACK ADJ ARC 90-210, G=GREEN ADJ
ARC 210-270, R=RED 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED
360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP3000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ
ARC 210-270, A=GRAY 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP3000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTARY NOZZLE.
B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY
360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP3500 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. LB=LIGHT BROWN, ADJUSTABLE ARC,
90-210, ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP815 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE, PRESSURE
REGULATED TO 40 PSI, MP ROTATOR NOZZLE. M=MAROON
AND GRAY ADJ ARC 90 TO 210, L=LIGHT BLUE AND GRAY 210
TO 270 ARC, O=OLIVE AND GRAY 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25-LF 1"
DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN.
HY100 FILTER SYSTEM. PRESSURE REGULATION: 25 PSI. FLOW
RANGE: .5 GPM - 15 GPM. 150 MESH STAINLESS STEEL
SCREEN.
DETAIL 2
SHEET IR-114
NIBCO 4660-T
3/4" SCHEDULE 40 MANUAL FLUSH VALVE. CONNECT TO DRIP
POLYTUBING FOR WINTERIZATION/BLOWOUT.
DETAIL 3
SHEET IR-114
AREA TO RECEIVE DRIP EMITTERS
HUNTER HE-B
POINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB.
COLOR CODED EMITTERS FOR FLOW RATES OF 0.5 GPH, 1.0
GPH, 2.0 GPH, 4.0 GPH, AND 6.0 GPH. CAN BE INSERTED INTO
1/2IN. AND 3/4IN. TUBING AND HAVE PRESSURE
COMPENSATING FROM 15 PSI-50 PSI. OPTIONAL DIFFUSER CAP
(HE) AVAILABLE.
EMITTER SCHEDULE:
-1 GALLON AND SMALLER: 2, HEB-5-B EMITTER PER PLANT (1
GPH TOTAL)
-5 GALLON: 2, HEB-10-B EMITTERS PER PLANT (2 GPH TOTAL)
-10-15 GALLONS & UPRIGHT JUNIPERS: 3, HEB-10-B EMITTERS
PER PLANT (3 GPH TOTAL)
-1” TO 2-1/2” CALIPER TREES: 4, HEB-10-B EMITTERS PER PLANT
(4 GPH TOTAL)
-3” TO 4” CALIPER TREES: 6, HEB-10-B EMITTERS PER PLANT (6
GPH TOTAL)
DETAIL 4
SHEET IR-114
L S R
LST RSTSST
M L O
K G R
K G R
B Y A
B Y A
LB
M L O
IRRIGATION SCHEDULE A
FV
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICV-G-FS 1"
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.
WITH FILTER SENTRY.
DETAIL 5
SHEET IR-114
HUNTER HQ-44LRC 1"
QUICK COUPLER VALVE, YELLOW RUBBER LOCKING COVER,
RED BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,
2-PIECE BODY.
DETAIL 6
SHEET IR-114
NIBCO 4660-S
SCHEDULE 40 MANUAL BALL VALVE, SAME SIZE AS MAINLINE
PIPE DIAMETER AT VALVE LOCATION. SIZE RANGE - 3/4" - 3"
DETAIL 7
SHEET IR-114
NIBCO T-113-K
CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS
HANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER AT VALVE
LOCATION. SIZE RANGE - 1/4IN. - 3IN.
DETAIL 8
SHEET IR-114
HUNTER IBV-FS 2"
1IN., 1-1/2IN., 2IN., AND 3IN. BRASS ELECTRIC MASTER VALVE,
GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET,
FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY
FACTORY INSTALLED OPTION.
DETAIL 9
SHEET IR-114
1” NIBCO T-113-K
1” CLASS 125 BRONZE MANUAL DRAIN VALVE WITH CROSS
HANDLE
DETAIL 10
SHEET IR-114
FEBCO 825Y 1"
REDUCED PRESSURE BACKFLOW PREVENTER
DETAIL 11
SHEET IR-114
HUNTER A2C-75D-PP
75-STATION DECODER CONTROLLER ON A PLASTIC PEDESTAL.
DETAIL 1
SHEET IR-115
HUNTER ICD-100
SINGLE STATION DECODER W/SURGE SUPPRESSION AND
GROUND WIRE. TO BE INSTALLED ON UNIVERSAL DECODER
STAKE KIT (DECSTAKE10).
DETAIL 5
SHEET IR-114
& DETAIL 7
SHEET IR-115
HUNTER WSS
WIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOOR
INTERFACE, CONNECTS TO HUNTER PCC, PRO-C, AND I-CORE
CONTROLLERS, INSTALL AS NOTED. INCLUDES 10 YEAR
LITHIUM BATTERY AND RUBBER MODULE COVER, AND GUTTER
MOUNT BRACKET.
DETAIL 2
SHEET IR-115
HUNTER HFS-200
FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2IN.
SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.
DETAIL 3
SHEET IR-115
WATER METER 2"
USE DEDICATED IRRIGATION TAP AND METER. SEE CIVIL FOR
TAP AND METER SIZE AND LOCATION.
DETAIL 4
SHEET IR-115
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON PLAN
DETAIL 5
SHEET IR-115
IRRIGATION DRIP SUPPLY TUBING: POLYETHYLENE PIPE SDR-7
SIZE: 3/4" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION SERVICE LINE: TYPE K COPPER PIPE
SIZE: 3/4" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
WIRE SLEEVE: PVC SCHEDULE 40
SIZE: 1"
DETAIL 5
SHEET IR-115
PIPE SLEEVE: PVC SCHEDULE 40
SIZE: DOUBLE THE SIZE OF PIPE INSERTED
DETAIL 5
SHEET IR-115
QC
MV
MD
FS
M
VALVE NUMBER
VALVE FLOW
VALVE SIZE
VALVE CALLOUT
#
##"
CONTROLLERA
WS
SP
IRRIGATION SCHEDULE A
NUMBER MODEL SIZE TYPE GPM
A1 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.48
A2 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.37
A3 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.48
A4 HUNTER ICV-G-FS 1"SHRUB ROTARY 13.4
A5 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.83
A6 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.8
A7 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 6.38
A8 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 5.54
A9 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 3.71
A10 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.33
A11 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.48
A12 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.36
A13 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 3.99
A14 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 4.02
A15 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.22
A16 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.27
A17 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.28
A18 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.33
A19 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 5.69
A20 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.24
A21 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 5.01
A22 HUNTER ICV-G-FS 1"SHRUB ROTARY 8.6
A23 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.74
A24 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 4.12
A25 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.46
A26 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.9
A27 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.75
A28 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.87
A29 HUNTER ICV-G-FS 1"SHRUB ROTARY 13.62
A30 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.12
A31 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.04
A32 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.18
A33 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.3
A34 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 10.02
A35 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.38
A36 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.48
A37 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 11.01
A38 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 11.36
A39 HUNTER ICV-G-FS 1"SHRUB ROTARY 2.2
VALVE SCHEDULE A
P.O.C. NUMBER: A
Water Source Information:Use dedicated irrigation tap and meter. See civil for tap and
meter size and location.
FLOW AVAILABLE
Water Meter Size:1-1/2"
Flow Available 40.32 GPM
PRESSURE AVAILABLE
Static Pressure at POC:80 PSI
Elevation Change:5.00 ft
Service Line Size:1 1/2"
Length of Service Line:20 ft
Pressure Available:74 PSI
DESIGN ANALYSIS
Maximum Station Flow:14.75 GPM
Flow Available at POC:40.32 GPM
Residual Flow Available:25.57 GPM
Critical Station:A27
Design Pressure:40 PSI
Friction Loss:1.5 PSI
Fittings Loss:0.15 PSI
Elevation Loss:0 PSI
Loss through Valve:3 PSI
Pressure Req. at Critical Station:44.7 PSI
Loss for Fittings:1.41 PSI
Loss for Main Line:14.1 PSI
Loss for POC to Valve Elevation:0 PSI
Loss for Backflow:11.4 PSI
Loss for Master Valve:0.8 PSI
Loss for Water Meter:0.43 PSI
Critical Station Pressure at POC:72.8 PSI
Pressure Available:74 PSI
Residual Pressure Available:1.18 PSI
CRITICAL ANALYSIS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-103
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
4
MATCHLINE-SEE SHEET IR-106
MATCHLINE-SEE SHEET IR1.1
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ THIRTY-SIX (36) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'A' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 1-1/2"
POINT OF CONNECTION 'A'
▪ USE 1-1/2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" & 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
QC
MV WINTERIZATION PROCEDURES:
TYPICAL POINT OF CONNECTION SCHEMATIC DIAGRAM
MAINLINE
6
2
3
5
TO
IRRIGATION
SYSTEM
3
5
3
6
3
7
8
7
10
8
9
8
9
1
10
MD
1" BACKFLOW DEVICE
3/4" & 1-1/2" K COPPER WATER SERVICE PIPE
MANUAL DRAIN VALVE, SEE SHEET IR-114 DETAIL 10
1" MASTER VALVE
1" FLOW SENSOR
1" PVC LINE, CLASS 200 PIPE
TURN OFF SYSTEM AT THE GATE
VALVE DOWNSTREAM OF THE
IRRIGATION METER. OPEN ONE
CONTROL VALVE TO RELIEVE
PRESSURE SLOWLY OPEN BLOW OUT
VALVE. REPEAT PROCEDURE FOR ALL
BLOW OUT VALVES ALONG IRRIGATION
MAINLINE.
FS
M
4
3
1 IRRIGATION SERVICE STUB OFF MAINLINE. SEE CIVIL FOR
TAP SIZE & LOCATION
IRRIGATION METER, SEE CIVIL FOR SIZE & LOCATION
2
11
11 1" MAINLINE, CLASS 200 PIPE
4 GATE VALVE
1" QUICK COUPLER
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
UE
UE
UE
UE
UE
UE
UE
UE
S
T
T
UE UE UE UE UE UE
E
K
K
K K K K K K K K B
BKKK
K K K K K
M
M
M
M
M
M
M
M
M
M
KK
BB
B
B
LBLB
LBLB
LBLB
LBLB
LB
LB
LB
LB
LBLB
LBLB
QC
QC
1"
1"
1"
1"
1"
1"
3 4"
1"
1"
3 4"
A10
1"6.33
A11
1"11.5
A12
1"11.4
A13
1"3.99
A14
1"4.02
A15
1"14.2
A16
1"14.3
A17
1"14.3
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP
SP
SP
SP
SP
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-104
SCALE: 1"=20'
0 10 20
MATCHLINE-SEE SHEET IR-102
MATCHLINE-SEE SHEET IR-105
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
3
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
S
S
S
S
S
S
S
S
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
S
S
S
S
S
UE
S
F
F
F
F
FF
F
F
F
F
F
F
F
F
S
S
S
S
F
F
S
F S
S
F
F
T
T
F
T
F
T T
T
T
T
F
T
E
S
S
F
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
F
MV
MV
S
S
S
S
S
R
S
S
S
L
S
S
L
L
R
S
S
S
R
L
S
S
S
S
S
R
L
S
S
S
SS
S
S
S
S
S
S
R
L
S
S
S
S
S
S
S
R
L
S
S
S
S
S
S
S
R
S
S
S
S
S
S
S
S
S
S
S
S
L
R
S
S
S
S
S
S
L
R
S
S
S
L
R
S
S
S
S
L
S
S
S
S
S
S
S
S
S
S
M
M
M
M
M
M
M
M
M
MMM
M
M
M
M
O
O
MM
L
M
M
M
M
M
M
M
M
M
O
O
M
M
M
M
M O
M
M
M
M
M
M
M
R
S
S
S
S
S
S
S
S
K
K
K
K
K
G
K
M
M
QC
MV
FS
MD
QC
CONTROLLERB
WS
QC
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
3 4"
1"
1"
1"
1"
3 4"
1"
3 4"
1"
1"
1"
1"
1"
1"
B30
1"9.68
B31
1"1.94 B32
1"10.8
B33
1"10.9
B34
1"10.1
B36
1"1.47
B37
1"3.65
B43
1"8.9
B44
1"15.1
B45
1"5.72
B46
1"1.64
B47
1"8.37B48
1"5.99
B49
1"4.84
B50
1"1.64
B51
1"4.99
B52
1"1.38
B54
B55
1"5.28
B56
1"8.75
1"
112"
1"
112"
3 4"
112"
FV
FV
B1
1"4.62
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FVB35
1"8.48
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV FV
FV
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
FV
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-105
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
6
MATCHLINE-SEE SHEET IR-108
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ FOURTEEN (14) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'B' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 1-1/2"
POINT OF CONNECTION 'B'
▪ USE 1-1/2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" OR 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
QC
MV WINTERIZATION PROCEDURES:
TYPICAL POINT OF CONNECTION SCHEMATIC DIAGRAM
MAINLINE
6
2
3
5
TO
IRRIGATION
SYSTEM
3
5
3
6
3
7
8
7
10
8
9
8
9
1
10
MD
1" BACKFLOW DEVICE
3/4" & 1-1/2" K COPPER WATER SERVICE PIPE
MANUAL DRAIN VALVE, SEE SHEET IR-114 DETAIL 10
1" MASTER VALVE
1" FLOW SENSOR
1-1/2" PVC LINE, CLASS 200 PIPE
TURN OFF SYSTEM AT THE GATE
VALVE DOWNSTREAM OF THE
IRRIGATION METER. OPEN ONE
CONTROL VALVE TO RELIEVE
PRESSURE SLOWLY OPEN BLOW OUT
VALVE. REPEAT PROCEDURE FOR ALL
BLOW OUT VALVES ALONG IRRIGATION
MAINLINE.
FS
M
4
3
1 IRRIGATION SERVICE STUB OFF MAINLINE. SEE CIVIL FOR
TAP SIZE & LOCATION
IRRIGATION METER, SEE CIVIL FOR SIZE & LOCATION
2
11
11 1" MAINLINE, CLASS 200 PIPE
4 GATE VALVE
1" QUICK COUPLER
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
UE
UE
UE
UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UEUE
UE
UE
UE
F
F
F
T
S
E
E
MV
MV
MV
MV
MV
S
S
S
S
S
S
R
S
S
S
S
S
S
S
L
B
B
B
B
BBBB
B
Y
Y
B
B
A
A
A
LSSSSSSRLSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
R
S
S
S
S
S
S
L
S R
L
S
S
S
S
S
S
S
S
RSSSSSSLRSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
S
QC
QC
QC
B B
Y
B
B
B
B
B
B
B
A
QC
1"
3 4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"1"
3 4"
B2
1"4.62
B3
1"2.94
B4
1"12.0 B5
1"7.13
B6
1"7.16
B7
1"11.1
B8
A23
1"3.74
A24
1"4.12
A25
1"9.46
A26
1"9.9
A27
1"14.8
A28
1"7.87
A32
1"4.18
A33
1"8.3
A34
1"10.0
A35
1"14.4
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-106
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
5
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
7
MATCHLINE-SEE SHEET IR-103
MATCHLINE-SEE SHEET IR-109
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
UE UE UE UE UE UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
T
T E
E
MV
MV
K K K K K K K K K B
K K K
R
LBLB
LBLB
LBLB
LB LB
LBLB
LBLB
LBLB
LB
LBLB
LB
QC
1"
1"
1"
3 4"
3 4"
1"
A18
1"14.3
A19
1"5.69
A20
1"14.2
A21
1"5.01
A22
1"8.6
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP
SP
SP
SPSP
SP
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER MP STRIP PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. LST=IVORY LEFT STRIP, SST=BROWN SIDE
STRIP, RST=COPPER RIGHT STRIP ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP1000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270
ARC, O=OLIVE 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP1000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270
ARC, O=OLIVE 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE. K=BLACK ADJ ARC 90-210, G=GREEN ADJ
ARC 210-270, R=RED 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED
360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP3000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTARY NOZZLE.
B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY
360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP800SR PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON
PRS40 BODY. ADJ=ORANGE AND GRAY ( ARC 90-210),
360=LIME GREEN AND GRAY (ARC 360)
DETAIL 1
SHEET IR-114
HUNTER MP815 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
M=MAROON AND GRAY ADJ ARC 90 TO 210, L=LIGHT BLUE AND
GRAY 210 TO 270 ARC, O=OLIVE AND GRAY 360 ARC ON PRS40
BODY.
DETAIL 1
SHEET IR-114
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25-LF 1"
DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN.
HY100 FILTER SYSTEM. PRESSURE REGULATION: 25 PSI.
FLOW RANGE: .5 GPM - 15 GPM. 150 MESH STAINLESS STEEL
SCREEN.
DETAIL 2
SHEET IR-114
NIBCO 4660-T
3/4" SCHEDULE 40 MANUAL FLUSH VALVE. CONNECT TO DRIP
POLYTUBING FOR WINTERIZATION/BLOWOUT.
DETAIL 3
SHEET IR-114
AREA TO RECEIVE DRIP EMITTERS
HUNTER HE-B
POINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB.
COLOR CODED EMITTERS FOR FLOW RATES OF 0.5 GPH, 1.0
GPH, 2.0 GPH, 4.0 GPH, AND 6.0 GPH. CAN BE INSERTED INTO
1/2IN. AND 3/4IN. TUBING AND HAVE PRESSURE
COMPENSATING FROM 15 PSI-50 PSI. OPTIONAL DIFFUSER CAP
(HE) AVAILABLE.
EMITTER SCHEDULE:
-1 GALLON AND SMALLER: 2, HEB-5-B EMITTER PER PLANT (1
GPH TOTAL)
-5 GALLON: 2, HEB-10-B EMITTERS PER PLANT (2 GPH TOTAL)
-10-15 GALLONS & UPRIGHT JUNIPERS: 3, HEB-10-B EMITTERS
PER PLANT (3 GPH TOTAL)
-1” TO 2-1/2” CALIPER TREES: 4, HEB-10-B EMITTERS PER
PLANT (4 GPH TOTAL)
-3” TO 4” CALIPER TREES: 6, HEB-10-B EMITTERS PER PLANT (6
GPH TOTAL)
DETAIL 4
SHEET IR-114
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICV-G-FS 1"
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.
WITH FILTER SENTRY.
DETAIL 5
SHEET IR-114
HUNTER HQ-44LRC 1"
QUICK COUPLER VALVE, YELLOW RUBBER LOCKING COVER,
RED BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,
2-PIECE BODY.
DETAIL 6
SHEET IR-114
NIBCO 4660-S
SCHEDULE 40 MANUAL BALL VALVE, SAME SIZE AS MAINLINE
PIPE DIAMETER AT VALVE LOCATION. SIZE RANGE - 3/4" - 3"
DETAIL 7
SHEET IR-114
NIBCO T-113-K
CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS
HANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER AT VALVE
LOCATION. SIZE RANGE - 1/4IN. - 3IN.
DETAIL 8
SHEET IR-114
HUNTER IBV-FS 2"
1IN., 1-1/2IN., 2IN., AND 3IN. BRASS ELECTRIC MASTER VALVE,
GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET,
FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY
FACTORY INSTALLED OPTION.
DETAIL 9
SHEET IR-114
1” NIBCO T-113-K
1” CLASS 125 BRONZE MANUAL DRAIN VALVE WITH CROSS
HANDLE
DETAIL 10
SHEET IR-114
FEBCO 825Y 1"
REDUCED PRESSURE BACKFLOW PREVENTER
DETAIL 11
SHEET IR-114
HUNTER A2C-75D-PP
75-STATION DECODER CONTROLLER ON A PLASTIC PEDESTAL.
DETAIL 1
SHEET IR-115
HUNTER ICD-100
SINGLE STATION DECODER W/SURGE SUPPRESSION AND
GROUND WIRE. TO BE INSTALLED ON UNIVERSAL DECODER
STAKE KIT (DECSTAKE10).
DETAIL 5
SHEET IR-114 &
DETAIL 7
SHEET IR-115
HUNTER WSS
WIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOOR
INTERFACE, CONNECTS TO HUNTER PCC, PRO-C, AND I-CORE
CONTROLLERS, INSTALL AS NOTED. INCLUDES 10 YEAR
LITHIUM BATTERY AND RUBBER MODULE COVER, AND GUTTER
MOUNT BRACKET.
DETAIL 2
SHEET IR-115
L S R
LST RSTSST
M L O
M L O
K G R
K G R
B Y A
800 A 800 F
M L O
QC
MV
MD
IRRIGATION SCHEDULE B
FV
WS
CONTROLLERB
SP
IRRIGATION SCHEDULE BMOUNT BRACKET.
HUNTER HFS-200
FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2IN.
SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.
DETAIL 3
SHEET IR-115
WATER METER 2"
USE DEDICATED IRRIGATION TAP AND METER. SEE CIVIL FOR
TAP AND METER SIZE AND LOCATION.
DETAIL 4
SHEET IR-115
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON PLAN
DETAIL 5
SHEET IR-115
IRRIGATION DRIP SUPPLY TUBING: POLYETHYLENE PIPE SDR-7
SIZE: 3/4" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION SERVICE LINE: TYPE K COPPER PIPE
SIZE: 3/4" UNLESS OTHERWISE NOTED ON PLAN
DETAIL 5
SHEET IR-115
WIRE SLEEVE: PVC SCHEDULE 40
SIZE: 1"
DETAIL 5
SHEET IR-115
PIPE SLEEVE: PVC SCHEDULE 40
SIZE: DOUBLE THE SIZE OF PIPE INSERTED
DETAIL 5
SHEET IR-115
FS
M
VALVE NUMBER
VALVE FLOW
VALVE SIZE
VALVE CALLOUT
#
##"
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-107
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
6
MATCHLINE-SEE SHEET IR-104
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
S
S
S
S
S
S
S
S
S
T
T
F
F
F
F
F
F
F
F F
F
F
F
F
F
F
F
F
S
F
F
F
F
S
S
S
S
T
T
T
T
T
T
E
UE
T
T
UE
UE
UE
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
F
F
MV
F
F
MV
MV
MV
F
F
MV
F
MV
F
MV
F
MV
F
MV
F
F
F
MV
MV
MV
UE
UE
S
S
S
S
S
R
L
S R
S
S
L
M
M
M
S
S
R
S
S
S
S
L
L
S
S
S
S
S
R
M
M
L
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
S
S
L
S
S
S
S
R
R
S
S
S
S
L
S
S
M
M
M
M
M
M
M
M
M
L
M
M
M
M
M
M
M
L
M
M
M
L
M
M
M
M
M
M
M
M
M
M
L
M
M
M
L
S
S
S
S
S
S
S
S
S
S
S
S
S
S
M
M
L
M
M
K
K
K
K
K
K K
KK
G
K
R
R
S
S
S
S
S
L
R
S
S
S
S
M
M
L
MM
M
M M
M
K
K
K
K
B
B
M M
M
M
M
M
M
M
M
G
M
M
M
M
M
M
M
O
M
QC
MV
FS
MD
QC
QC
CONTROLLERC
WS
1"
C1
1"10.5
QC
1"
1"
1"
1"
3 4"
3 4"
3 4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"1"
1"
1"
3 4"
1"
1"1"
1"
C2
1"16.2
C3
1"12.8
C4
1"16.4
C5
1"5.63
C17
1"3.0
C18
1"10.3
C19
1"6.27
C20
1"15.9
C21
1"13.2
C22
C42
1"4.76
B20
1"9.39
B21
1"11.2
B22
1"16.4
B23
1"16.0
B24
1"7.87
B25
1"16.0
B26
1"13.7
B27
1"14.4
B38
1"3.24
B39
1"1.57
B40
1"2.64
B41
1"12.5
B42
1"5.28
B53
1"1.93
B54
1"2.2
B57
1"15.7 B58
1"3.08
B59
1"3.66B60
1"3.08
B61
1"4.87
1"
112"
1"
112"
112"
112"3 4"
112"
1"
112"
112"
1"
B28
1"10.3
B29
1"4.59
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FVFV
FV
FV
FV
FV
FV
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP SPSP
SP
SPSP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-108
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
9
MATCHLINE-SEE SHEET IR-110
MATCHLINE-SEE SHEET IR-105
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
▪ ONE (1) 75 STATION CONTROLLER, SEE LEGEND.
▪ THIRTY-SIX (36) OPEN STATIONS FOR FUTURE EXPANSION.
▪STATION RUN ORDER SHALL MATCH PLANS.
▪ LOCATE CONTROLLER IN THE UTILITY CLOSET AS SPECIFIED ON
THE BUILDING PLANS. VERIFY LOCATION WITH OWNER OR
REPRESENTATIVE.
▪ 120 VAC POWER TO CONTROLLER LOCATION SHALL BE PROVIDED
BY OTHERS. HOOK-UP OF CONTROLLERS TO 120 VAC SHALL BE
PERFORMED BY THE LANDSCAPE CONTRACTOR.
▪CONDUIT FROM INSIDE THE BUILDING TO EXTERIOR IRRIGATION
SYSTEM SHALL BE PROVIDED BY OTHERS.
CONTROLLER 'C' NOTE
STATIC PRESSURE: +/- 80 ASSUMED SIZE
OF TAP: 2"
POINT OF CONNECTION 'C'
▪ USE 2" TAP AND INTO THE DOMESTIC WATER LINE
AFTER THE METER.
▪ 3/4" & 1-1/2" PER PLAN TYPE K COPPER SERVICE FROM
THE TAP THROUGH THE IRRIGATION BACKFLOW, TO THE
MASTER VALVE.
▪ CONTRACTOR SHALL VERIFY LOCATION OF THE
EQUIPMENT, IN FIELD WITH OWNER OR OWNER'S
AUTHORIZED REPRESENTATIVE AND/OR LANDSCAPE
ARCHITECT.
▪ SEE POINT OF CONNECTION DIAGRAM, THIS SHEET, FOR
THE IRRIGATION SYSTEM EQUIPMENT CONFIGURATION.
▪THE IRRIGATION CONTRACTOR SHALL FIELD VERIFY THE
STATIC & OPERATING WATER PRESSURE SHOWN ABOVE
PRIOR TO CONSTRUCTION. IF PRESSURE IS UNKNOWN,
THE CONTRACTOR MUST TEST WATER PRESSURE AND
CONTACT THE LANDSCAPE ARCHITECT WITH THE
RESULTS TO ENSURE SYSTEM WILL BE OPERATIONAL.
SEE GENERAL IRRIGATION NOTES.
▪ WHEN WATER PRESSURE TO THE IRRIGATION SYSTEM
EXCEEDS 100 PSI, THE IRRIGATION CONTRACTOR SHALL
INSTALL A PRESSURE REDUCING / REGULATING VALVE
(PRV) TO LIMIT THE WATER TO 80 PSI MAXIMUM. WHEN
PRESSURE DROPS BELOW 65 PSI, THE IRRIGATION
CONTRACTOR SHALL INSTALL A BOOSTER PUMP TO A
MINIMUM PRESSURE OF 80 PSI.
QC
MV WINTERIZATION PROCEDURES:
TYPICAL POINT OF CONNECTION SCHEMATIC DIAGRAM
MAINLINE
6
2
3
5
TOIRRIGATION
SYSTEM
3
5
3
6
3
7
8
7
10
8
9
8
9
1
10
MD
1" BACKFLOW DEVICE
3/4" & 1-1/2" K COPPER WATER SERVICE PIPE
MANUAL DRAIN VALVE, SEE SHEET IR-114 DETAIL 10
1" MASTER VALVE
1" FLOW SENSOR
1-1/2" PVC LINE, CLASS 200 PIPE
TURN OFF SYSTEM AT THE GATE
VALVE DOWNSTREAM OF THE
IRRIGATION METER. OPEN ONE
CONTROL VALVE TO RELIEVE
PRESSURE SLOWLY OPEN BLOW OUT
VALVE. REPEAT PROCEDURE FOR ALL
BLOW OUT VALVES ALONG IRRIGATION
MAINLINE.
FS
M
4
3
1 IRRIGATION SERVICE STUB OFF MAINLINE. SEE CIVIL FOR
TAP SIZE & LOCATION
IRRIGATION METER, SEE CIVIL FOR SIZE & LOCATION
2
11
11 1" MAINLINE, CLASS 200 PIPE
4 GATE VALVE
1" QUICK COUPLER
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
UE
S
UE
S
S
S
S
S
F
F
F
F
F
S
S
T
S
T
F
UE
UE
MV
MV
MV
MV
MV
MV
F
MV
F
UE
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
L
L
L
O
K
K K
KK
KK
K
K
K
K
KKK
K
K
R
R
M M M M M
M
M
M
M
M
L
M
OM
M
M
M
M
M
M
M
L
M
M
M
M
M
M
M
M
O
M
M
M
M
M
M
O
1"
1"
3 4"
1"1"
1"
1"
1"
1"
1"
B8
1"8.4
B9
1"6.0
B10
1"2.87
B11
1"6.09
B12
1"8.87
B13
1"10.8
B14
1"1.62
B15
1"10.5
B19
1"7.16
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP SP
SP
SP
SP
SP
SP
SP
SP
NUMBER MODEL SIZE TYPE GPM
B1 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.62
B2 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.62
B3 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 2.94
B4 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.99
B5 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.13
B6 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.16
B7 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.08
B8 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.4
B9 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.0
B10 HUNTER ICV-G-FS 1"SHRUB ROTARY 2.87
B11 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.09
B12 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.87
B13 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.77
B14 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 1.62
B15 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.53
B16 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.81
B17 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.29
B18 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.12
B19 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.16
B20 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 9.32
B21 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.15
B22 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.38
B23 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.01
B24 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 7.73
B25 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.01
B26 HUNTER ICV-G-FS 1"SHRUB ROTARY 13.71
B27 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.45
B28 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 10.3
B29 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.59
B30 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.68
B31 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 1.94
B32 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.8
B33 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 10.87
B34 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.12
B35 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.48
B36 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 1.47
B37 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.65
B38 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.24
B39 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.57
B40 HUNTER ICV-G-FS 1"SHRUB ROTARY 2.64
B41 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.54
B42 HUNTER ICV-G-FS 1"SHRUB ROTARY 5.28
B43 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.9
B44 HUNTER ICV-G-FS 1"SHRUB ROTARY 15.13
B45 HUNTER ICV-G-FS 1"SHRUB ROTARY 5.72
B46 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.64
B47 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.37
B48 HUNTER ICV-G-FS 1"SHRUB ROTARY 5.99
B49 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.84
B50 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.64
B51 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.99
B52 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.38
B53 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.93
B54 HUNTER ICV-G-FS 1"SHRUB ROTARY 2.2
B55 HUNTER ICV-G-FS 1"SHRUB ROTARY 5.28
B56 HUNTER ICV-G-FS 1"SHRUB ROTARY 8.75
B57 HUNTER ICV-G-FS 1"SHRUB ROTARY 15.67
B58 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.08
B59 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.66
B60 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.08
B61 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.87
VALVE SCHEDULE B
P.O.C. NUMBER: B
Water Source Information:Use dedicated irrigation tap and meter. See civil for tap and
meter size and location.
FLOW AVAILABLE
Water Meter Size:1-1/2"
Flow Available 40.32 GPM
PRESSURE AVAILABLE
Static Pressure at POC:80 PSI
Elevation Change:5.00 ft
Service Line Size:1 1/2"
Length of Service Line:20 ft
Pressure Available:74 PSI
DESIGN ANALYSIS
Maximum Station Flow:16.38 GPM
Flow Available at POC:40.32 GPM
Residual Flow Available:23.94 GPM
Critical Station:B22
Design Pressure:40 PSI
Friction Loss:0.49 PSI
Fittings Loss:0.05 PSI
Elevation Loss:0 PSI
Loss through Valve:3 PSI
Pressure Req. at Critical Station:43.5 PSI
Loss for Fittings:1.33 PSI
Loss for Main Line:13.3 PSI
Loss for POC to Valve Elevation:0 PSI
Loss for Backflow:11.3 PSI
Loss for Master Valve:0.8 PSI
Loss for Water Meter:0.55 PSI
Critical Station Pressure at POC:70.8 PSI
Pressure Available:74 PSI
Residual Pressure Available:3.16 PSI
CRITICAL ANALYSIS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-109
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
0
8
MATCHLINE-SEE SHEET IR-111
MATCHLINE-SEE SHEET IR-106
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
UE
UE
UE
UE
UE
UE
UE
UE
UE UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
S
S
UE
UE
T
T
T
T
T
FF
F
F
F
F
F
F
F
F
F
F F
F
F
F
FF
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
FS
S
S
S
F
S F
T
F
S
S
S
S
F
T
UE
ST
M
STM
S
UE
UE
UE
UE
UE
UEUE
UE
UE
UE
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
MV
S
S
S
S
S
S
S
S
S
S
S
S
S
R
L
S
S
R
R
L
R
S
S
S
S
S
S
S
S
S
S
S
S
S
L
R
S
S
S
S
S
S
S S S
S
S
S
S
S
S
S
S
S
S
S
S
L
M
M
M
G
K
K K
K
K
G
K
K
K
K
M
M
G
K
KK
G R
M
M
M
M
M
M
M
M
M
MM
M
M
M
M
M
M
M
M
M
M
M
M
M
K
K
K
MM
M
MMM
M
M M
M
M
M
M O
M
M
M
M
M
M
M
M
M
O
M
M
M
M
M
L
L
M
M
L
M
M
M
M
O
O
K
K
KK
K
K
K
K
L
S
S
R
S
S
R
L
S
S S
R
L
L
L
S
S
S
R
R
R
R
R
L
L
L
L
R
S
S
S
S
S
S
S
S
S
R
L
L
L
L
S S
S
S
R
R
R
M
M
M
M M
M
M
M
M
M
S
M
M
M
M
M
M
S
L
S
M
M
M
L
M
M
M
M
M
M
M
M
M
M
M
L
M
M
M
M
M
M
M
L
L
M
M
O
S
QC
3 4"
1"
1"
1"
1"
1"1"
1"
1"
1"
1"
1"
1"
3 4"
1"
1"
3 4"
1"
3 4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
3 4"
1"
1"
1"
3 4"
1"
C6
1"16.2
C8
1"3.74
C9
1"15.8C10
1"9.02
C11
1"2.32
C12
1"14.2
C13
1"10.2
C14
1"3.61
C15
1"12.1
C16
1"9.57
C22
1"7.6
C23
1"16.0
C24
1"1.32
C25
1"1.98
C26
1"1.32
C27
1"3.86
C28
1"3.82
C29
1"11
C30
1"1.32
C31
1"9.85
C33
1"1.32
C38
1"13.0
C39
1"12.0
C41
1"12.7
B18
1"12.1
C43
1"5.87
C44
1"7.27
C45
1"4.62
C46
1"1.0
C47
1"7.11
1"
112"
1"
C37
1"4.41
C32
1"6.06
C7
1"12.6
C40
1"7.35
FV
FV
3 4"
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
FV
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP SP
SP
SP
SP
SP
SP
SP
SP
SP
SPSP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-110
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
1
1
MATCHLINE-SEE SHEET IR-112
MATCHLINE-SEE SHEET IR-108
JR
EDN
MATCHLINE-SEE SHEET IR-113
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
S
SUE
UE
UE
UE
UE
UE
UE
UE
UE
UE
T
F
F
T
E
STM
STM
STM
ST
M
STM
STM
STM
STM
STM
STMSTM
UE
MV
MV
F
M
M
M
M
K
K
G
K
K
M
M
M
M
L
S
S
L
R
S
L
R
S
L
L
L
R
R
R
L
S
QC
QC
1"
1"1"
1"
1"
1"
1"
C34
1"6.68
C35
1"8.58
B16
1"6.81
B17
1"6.29
B18
1"12.1
FVFV
FV
FV
QC C36
1"2.2
3 4"
C48
1"5.71
FV
FV
FV
FV
SP
SP
SP
SP
SP
SP
SP
SP
SP
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER MP STRIP PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR
NOZZLE. LST=IVORY LEFT STRIP, SST=BROWN SIDE STRIP,
RST=COPPER RIGHT STRIP ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP1000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE, PRESSURE
REGULATED TO 40 PSI, MP ROTATOR NOZZLE. M=MAROON ADJ
ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360
ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP1000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,
O=OLIVE 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR
NOZZLE. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270,
R=RED 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP2000 PROS-12-PRS40-CV (2)
SHRUB ROTATOR, 12IN. POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE.
K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED
360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP3000 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR
NOZZLE. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270,
A=GRAY 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
HUNTER MP800SR PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE, PRESSURE
REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY.
ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND
GRAY (ARC 360)
DETAIL 1
SHEET IR-114
HUNTER MP815 PROS-06-PRS40-CV
SHRUB ROTATOR, 6IN. POP-UP WITH CHECK VALVE, PRESSURE
REGULATED TO 40 PSI, MP ROTATOR NOZZLE. M=MAROON AND
GRAY ADJ ARC 90 TO 210, L=LIGHT BLUE AND GRAY 210 TO 270
ARC, O=OLIVE AND GRAY 360 ARC ON PRS40 BODY.
DETAIL 1
SHEET IR-114
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICZ-101-25-LF 1"
DRIP CONTROL ZONE KIT. 1IN. ICV GLOBE VALVE WITH 1IN.
HY100 FILTER SYSTEM. PRESSURE REGULATION: 25 PSI. FLOW
RANGE: .5 GPM - 15 GPM. 150 MESH STAINLESS STEEL SCREEN.
DETAIL 2
SHEET IR-114
NIBCO 4660-T
3/4" SCHEDULE 40 MANUAL FLUSH VALVE. CONNECT TO DRIP
POLYTUBING FOR WINTERIZATION/BLOWOUT.
DETAIL 3
SHEET IR-114
AREA TO RECEIVE DRIP EMITTERS
HUNTER HE-B
POINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB.
COLOR CODED EMITTERS FOR FLOW RATES OF 0.5 GPH, 1.0
GPH, 2.0 GPH, 4.0 GPH, AND 6.0 GPH. CAN BE INSERTED INTO
1/2IN. AND 3/4IN. TUBING AND HAVE PRESSURE COMPENSATING
FROM 15 PSI-50 PSI. OPTIONAL DIFFUSER CAP (HE) AVAILABLE.
EMITTER SCHEDULE:
-1 GALLON AND SMALLER: 2, HEB-5-B EMITTER PER PLANT (1
GPH TOTAL)
-5 GALLON: 2, HEB-10-B EMITTERS PER PLANT (2 GPH TOTAL)
-10-15 GALLONS & UPRIGHT JUNIPERS: 3, HEB-10-B EMITTERS
PER PLANT (3 GPH TOTAL)
-1” TO 2-1/2” CALIPER TREES: 4, HEB-10-B EMITTERS PER PLANT
(4 GPH TOTAL)
-3” TO 4” CALIPER TREES: 6, HEB-10-B EMITTERS PER PLANT (6
GPH TOTAL)
DETAIL 4
SHEET IR-114
SYMBOL MANUFACTURER/MODEL/DESCRIPTION DETAIL
HUNTER ICV-G-FS 1"
1IN., 1-1/2IN., 2IN., AND 3IN. PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT
THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE.
WITH FILTER SENTRY.
DETAIL 5
SHEET IR-114
HUNTER HQ-44LRC 1"
QUICK COUPLER VALVE, YELLOW RUBBER LOCKING COVER,
RED BRASS AND STAINLESS STEEL, WITH 1IN. NPT INLET,
2-PIECE BODY.
DETAIL 6
SHEET IR-114
NIBCO 4660-S
SCHEDULE 40 MANUAL BALL VALVE, SAME SIZE AS MAINLINE
PIPE DIAMETER AT VALVE LOCATION. SIZE RANGE - 3/4" - 3"
DETAIL 7
SHEET IR-114
NIBCO T-113-K
CLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSS
HANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER AT VALVE
LOCATION. SIZE RANGE - 1/4IN. - 3IN.
DETAIL 8
SHEET IR-114
HUNTER IBV-FS 2"
1IN., 1-1/2IN., 2IN., AND 3IN. BRASS ELECTRIC MASTER VALVE,
GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET,
FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY
FACTORY INSTALLED OPTION.
DETAIL 9
SHEET IR-114
L S R
LST RSTSST
M L O
M L O
K G R
K G R
B Y A
800 A 800 F
M L O
QC
MV
IRRIGATION SCHEDULE C
FV
IRRIGATION SCHEDULE CFACTORY INSTALLED OPTION.
1” NIBCO T-113-K
1” CLASS 125 BRONZE MANUAL DRAIN VALVE WITH CROSS
HANDLE
DETAIL 10
SHEET IR-114
FEBCO 825Y 1"
REDUCED PRESSURE BACKFLOW PREVENTER
DETAIL 11
SHEET IR-114
HUNTER A2C-75D-PP
75-STATION DECODER CONTROLLER ON A PLASTIC PEDESTAL.
DETAIL 1
SHEET IR-115
HUNTER ICD-100
SINGLE STATION DECODER W/SURGE SUPPRESSION AND
GROUND WIRE. TO BE INSTALLED ON UNIVERSAL DECODER
STAKE KIT (DECSTAKE10).
DETAIL 5
SHEET IR-114
& DETAIL 7
SHEET IR-115
HUNTER WSS
WIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOOR
INTERFACE, CONNECTS TO HUNTER PCC, PRO-C, AND I-CORE
CONTROLLERS, INSTALL AS NOTED. INCLUDES 10 YEAR
LITHIUM BATTERY AND RUBBER MODULE COVER, AND GUTTER
MOUNT BRACKET.
DETAIL 2
SHEET IR-115
HUNTER HFS-200
FLOW SENSOR FOR USE WITH ACC CONTROLLER, 2IN.
SCHEDULE 40 SENSOR BODY, 24 VAC, 2 AMP.
DETAIL 3
SHEET IR-115
WATER METER 2"
USE DEDICATED IRRIGATION TAP AND METER. SEE CIVIL FOR
TAP AND METER SIZE AND LOCATION.
DETAIL 4
SHEET IR-115
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON PLAN
DETAIL 5
SHEET IR-115
IRRIGATION DRIP SUPPLY TUBING: POLYETHYLENE PIPE SDR-7
SIZE: 3/4" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
SIZE: 1" UNLESS OTHERWISE NOTED ON THE PLAN
DETAIL 5
SHEET IR-115
IRRIGATION SERVICE LINE: TYPE K COPPER PIPE
SIZE: 3/4" UNLESS OTHERWISE NOTED ON PLAN
DETAIL 5
SHEET IR-115
WIRE SLEEVE: PVC SCHEDULE 40
SIZE: 1"
DETAIL 5
SHEET IR-115
PIPE SLEEVE: PVC SCHEDULE 40
SIZE: DOUBLE THE SIZE OF PIPE INSERTED
DETAIL 5
SHEET IR-115
MD
FS
M
VALVE NUMBER
VALVE FLOW
VALVE SIZE
VALVE CALLOUT
#
##"
CONTROLLERC
WS
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-111
SCALE: 1"=20'
0 10 20
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
1
0
MATCHLINE-SEE SHEET IR-109
MATCHLINE-SEE SHEET IR-112
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
QC 3 4"
C51
1"8.23
SP NUMBER MODEL SIZE TYPE GPM
C1 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.51
C2 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.2
C3 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.8
C4 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.37
C5 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 5.63
C6 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.24
C7 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.62
C8 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.74
C9 HUNTER ICV-G-FS 1"SHRUB ROTARY 15.85
C10 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.02
C11 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 2.32
C12 HUNTER ICV-G-FS 1"SHRUB ROTARY 14.2
C13 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.15
C14 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 3.61
C15 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.1
C16 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.57
C17 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.0
C18 HUNTER ICV-G-FS 1"SHRUB ROTARY 10.34
C19 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.27
C20 HUNTER ICV-G-FS 1"SHRUB ROTARY 15.89
C21 HUNTER ICV-G-FS 1"SHRUB ROTARY 13.2
C22 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 7.6
C23 HUNTER ICV-G-FS 1"SHRUB ROTARY 16.0
C24 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.32
C25 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.98
C26 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.32
C27 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.86
C28 HUNTER ICV-G-FS 1"SHRUB ROTARY 3.82
C29 HUNTER ICV-G-FS 1"SHRUB ROTARY 11
C30 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.32
C31 HUNTER ICV-G-FS 1"SHRUB ROTARY 9.85
C32 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.06
C33 HUNTER ICV-G-FS 1"SHRUB ROTARY 1.32
C34 HUNTER ICV-G-FS 1"SHRUB ROTARY 6.68
C35 HUNTER ICV-G-FS 1"SHRUB ROTARY 8.58
C36 HUNTER ICV-G-FS 1"SHRUB ROTARY 2.2
C37 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 4.41
C38 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.96
C39 HUNTER ICV-G-FS 1"SHRUB ROTARY 11.96
C40 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 7.35
C41 HUNTER ICV-G-FS 1"SHRUB ROTARY 12.73
C42 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 4.76
C43 HUNTER ICV-G-FS 1"SHRUB ROTARY 5.87
C44 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.27
C45 HUNTER ICV-G-FS 1"SHRUB ROTARY 4.62
C46 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 1.0
C47 HUNTER ICV-G-FS 1"SHRUB ROTARY 7.11
C48 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 5.71
C49 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 7.1
C50 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.75
C51 HUNTER ICZ-101-25-LF 1"AREA FOR DRIP EMITTERS 8.23
VALVE SCHEDULE C
P.O.C. NUMBER: C
Water Source Information:Use dedicated irrigation tap and meter. See civil for tap and
meter size and location.
FLOW AVAILABLE
Water Meter Size:2"
Flow Available 70.55 GPM
PRESSURE AVAILABLE
Static Pressure at POC:80 PSI
Elevation Change:5.00 ft
Service Line Size:2"
Length of Service Line:20 ft
Pressure Available:77 PSI
DESIGN ANALYSIS
Maximum Station Flow:16.37 GPM
Flow Available at POC:70.55 GPM
Residual Flow Available:54.18 GPM
Critical Station:C41
Design Pressure:40 PSI
Friction Loss:0.39 PSI
Fittings Loss:0.04 PSI
Elevation Loss:0 PSI
Loss through Valve:3 PSI
Pressure Req. at Critical Station:43.4 PSI
Loss for Fittings:1.79 PSI
Loss for Main Line:17.9 PSI
Loss for POC to Valve Elevation:0 PSI
Loss for Backflow:11.9 PSI
Loss for Master Valve:0.8 PSI
Loss for Water Meter:0.4 PSI
Critical Station Pressure at POC:76.1 PSI
Pressure Available:77 PSI
Residual Pressure Available:0.86 PSI
CRITICAL ANALYSIS
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-112
SCALE: 1"=20'
0 10 20
MATCHLINE-SEE SHEET IR-110
JR
EDN
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
STM
STM
STM
STM
STM
STM
FV
FV
FV
FVFV
FV
FV
FV
QC
FV
FV
3 4"
1"
C49
1"7.1
C50
1"8.75
SP
SP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION PLAN
IR-113
SCALE: 1"=20'
0 10 20
MATCHLINE-SEE SHEET IR-110 MATCHLINE-SEE SHEET IR-111
JR
EDN
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
-
1
1
2
CAUTIONUTILITIES EXIST WITHIN CONSTRUCTIONLIMITS. CONTRACTOR IS RESPONSIBLE FORIDENTIFYING THEIR LOCATION PRIOR TOCONSTRUCTION.
KEYMAP
US
H
W
Y
2
8
7
ST
R
A
S
B
U
R
G
D
R
TRIA
N
G
L
E
D
R
AVO
N
D
A
L
E
R
D
IR-102
IR-103 IR-104
IR-106 IR-107IR-105
IR-109IR-108
IR-111IR-110
IR-113IR-112
IR-101
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION NOTES &
DETAILS
IR-114
JR
EDN
LATERAL TEE OR ELL
SPRAY BODY
FINISH GRADE
CURB OR PAVING
1
2
3
4
7
1
2
4
7
8
3" MAX
3
SWING PIPE ELBOW
SWING PIPE5
6 5
LATERAL PIPE8
6
SPRAY/ROTATOR
NOZZLE
NOTES:
1. MAXIMUM LENGTH OF SECONDARY WIRE PATH (14 AWG) FROM
FIELD DECODER TO SOLENOID IS 450 FEET.
2. PLACE 3 FEET OF EXTRA WIRE IN EVERY VALVE BOX FOR EASIER
SERVICING.
DRIP ZONE KIT PER PLAN
PVC SLIP UNIONS
2 4103
7
14 13 8 9
1
12
5
PVC MAINLINE PER PLAN
FIELD DECODER PER PLAN
WIRES FROM THE VALVE SPLICED TO
BLACK DECODER WIRES
FINISH GRADE
DBRY-6 WIRE CONNECTORS (4)
1
3
4
6
7
2
5
8 6" MINIMUM LAYER OF 3/4" MINUS
WASHED GRAVEL
9
COMMUNICATION WIRE TO NEXT DEVICE
(FIELD DECODER, SENSOR DECODER, LINE
SURGE PROTECTOR OR CONTROLLER)
TWO-WIRE CABLE WITH JACKET TO NEXT
DEVICE (FIELD DECODER, SENSOR DECODER,
LINE SURGE PROTECTOR OR CONTROLLER)
10
12
13
11
GROUNDING WIRE WITH PLATE (IF
NECESSARY)
15
PVC LATERAL LINE PER PLAN
BLACK POLYTUBING PER PLAN14
PVC TO POLYTUBING ADAPTER
15
11
CARSON VALVE BOX OR APPROVED
EQUAL. STATION NUMBER BRAND ON LID.
6
3"
M
I
N
.
FINISH GRADE
POLYPIPE DRIP LINE
1 2
4
3
6
6
1
2
3
6 3" MINIMUM LAYER
OF 3/4" MINUS
WASHED GRAVEL
MANUAL FLUSH BALL
VALVE
4
CARSON VALVE BOX OR
APPROVED EQUAL. FV
BRAND ON LID.
PLANTING BACKFILL MATERIAL
POLY DRIP TUBING
PLANT ROOT BALL
EMITTER-STAKE TO EDGE OF
ROOTBALL
EMITTER TUBING - 60' MAX. LENGTHPLAN
DOWN
4:1 SLOPE
PLANTING MATERIAL
PLAN
EMITTER - REFER TO
IRRIGATION SCHEDULE FOR
DRIP EMITTER SCHEDULE.
REFER TO SPECIFICATION
FOR MANUFACTURER &
MODEL NUMBER.
MULCH LAYER
EMITTER
MICRO-TUBING, COLOR
OR APPROVED EQUAL
POLY DRIP TUBING - SEE
IRRIGATION LEGEND
6" - 10 GAUGE JUTE STAKE
OR APPROVED EQUAL
1. INSTALL EMITTERS ON
OPPOSING SIDES OF THE ROOT
BALL. THREE OR MORE EMITTERS
SHALL BE EQUALLY SPACED
AROUND ROOT BALL.
2. EMITTERS ARE TO BE
INSTALLED TO CLEAR SURFACE BY
A MINIMUM OF 1" AND A MAXIMUM
2'.
3. FLUSH ALL LINES THOROUGHLY,
INCLUDING EMITTER
MICRO-TUBING PRIOR TO EMITTER
INSTALLATION.
4. IF PLANTING ON A 4:1 SLOPE OR
STEEPER, INSTALL BOTH
EMITTERS ON UPHILL SIDE OF
ROOT BALL.
5. EMITTERS SHALL BE
SELF-FLUSHING, PRESSURE
COMPENSATING-TYPE UNLESS
NOTED OTHERWISE WITHIN
TECHNICAL SPECIFICATIONS.
NOTES:
891011121211
1 11 2 3 4 5 6 7
PVC MAINLINE PER PLAN
FIELD DECODER PER PLAN
WIRES FROM THE VALVE SPLICED TO
BLACK DECODER WIRES
FINISH GRADE
COMMUNICATION WIRE FROM
DECODERDBRY-6 WIRE CONNECTORS (4)
REMOTE CONTROL VALVE PER PLAN
1
2
3
5
6
4
7
6" MINIMUM LAYER OF 3/4" MINUS
WASHED GRAVEL
8
TWO-WIRE CABLE WITH JACKET TO NEXT
DEVICE (FIELD DECODER, SENSOR
DECODER, LINE SURGE PROTECTOR OR
CONTROLLER)
9
11
12
PVC LATERAL LINE PER PLAN10
13
COMMUNICATION WIRE TO NEXT DEVICE
(FIELD DECODER, SENSOR DECODER,
LINE SURGE PROTECTOR OR
CONTROLLER)
NOTES:
1. MAXIMUM LENGTH OF SECONDARY WIRE PATH (14 AWG) FROM
FIELD DECODER TO SOLENOID IS 450 FEET.
2. PLACE 3 FEET OF EXTRA WIRE IN EVERY VALVE BOX FOR EASIER
SERVICING.
14
GROUNDING WIRE WITH PLATE (IF
NECESSARY)
CARSON VALVE BOX OR APPROVED
EQUAL. STATION NUMBER BRAND ON LID.
3"
M
I
N
.
FINISH GRADE
QUICK-COUPLING VALVE
6" LONG BRASS NIPPLE
PREFABRICATED SWING JOINT
2" x 2" REDWOOD STAKE WITH
STAINLESS STEEL GEAR CLAMPS OR
EQUIVALENT SUPPORT SYSTEM
3" MINIMUM DEPTH OF 3/4-INCH
WASHED GRAVEL
231
9 8 7
4
5
2
3
1
4
5
6
9
3"
M
I
N
.
CARSON VALVE BOX OR APPROVED
EQUAL. QC BRAND ON LID.
6
PVC SCH 40 TEE OR ELL7
PVC MAINLINE8
PVC MALE ADAPTER
PLASTIC BALL VALVE (SIZEDPER MAINLINE)
EXTENSION SECTION ASNECESSARY TO MEET GRADE
FINISH GRADE AT 1" BELOW TOPOF BOX IN TURF AREAS: 2"BELOW TOP OF BOX INSHRUB/GROUNDCOVER AREAS
IRRIGATION MAINLINE
18
"
1 2 3
4576
1
2
3 7
6
5
4
CARSON VALVE BOX OR
APPROVED EQUAL. BV
BRAND ON LID.
3" MINIMUM LAYER OF
3/4" MINUS WASHED
GRAVEL
KEY HEAD PER HEAD
GATE VALVE (SIZED PER
MAINLINE)
IRRIGATION MAINLINE
4" PVC SLEEVE
FINISH GRADE AT 1" BELOWTOP OF BOX IN TURF AREAS:2" BELOW TOP OF BOX INSHRUB/GROUNDCOVERAREAS
1 2 3 4
7
6 5
1
2
3
4
5
6
7
18
"
CARSON VALVE BOX OR
APPROVED EQUAL.
3" MINIMUM LAYER OF
3/4" MINUS WASHED
GRAVEL
3"
M
I
N
.
REMOTE CONTROL VALVE
PER PLAN
FINISH GRADE
COPPER TO PVC FITTING
ID WIRES WITH JACKET
SCH 80 CLOSE NIPPLE
K COPPER PIPE PER PLAN
12 6 9 8
73
1
4
5
2
1
2
3
5
6
7
8
9
10
DECODER PER PLAN10
11
11
5
PVC UNION12
DBRY-6 WIRE CONNECTORS (2)4
GROUNDING WIRE WITH PLATE (IF
NECESSARY)
CARSON VALVE BOX OR APPROVED
EQUAL. MV BRAND ON LID.
3" MINIMUM LAYER OF 3/4"
MINUS WASHED GRAVEL
1
2
3
4
5
6
7
8
9
10
11
12
3"
1
2
3
4
5
6
7
8
9
10
11
12
3/4" CRUSHED GRAVEL SUMP
1 CU. FT.
2" CL160 PVC ACCESS SLEEVE -
LENGTH AS REQUIRED
3/4" FxF SCH.80 PVC 90 ELL (2)
3/4"xCL PVC NIPPLE SCH. 80 (2)
3/4" CRUSHED GRAVEL SUMP
SEE TECHNICAL SPECIFICATIONS
FOR SUMP SIZE
PRESSURE MAINLINE
3/4"x4" PVC NIPPLE SCH. 80
SOIL BLANKET COVERING SUMP
3/4" MxF SCH.40 PVC 90 ELL
3/4" McDONALD #6101 SERIES VALVE
3/4"x6" SCH. 80 GALVANIZED STEEL
NIPPLE
2" VALVE MARKER
CARSON VALVE BOX OR
APPROVED EQUAL. DV
BRAND ON LID.
ENCLOSURE PER IRRIGATI0N
LEGEND
BRASS WYE STRAINER W/60 MESH
SCREEN
MAINLINE CONNECTION- ADAPT AS
NECESSARY ALL WORK SHALL
CONFORM TO ALL APPLICABLE
CODES
12"X12"X12" THRUST BLOCKS
4" CONCRETE PAD - SLOPE TO
DRAIN AWAY FROM BACKFLOW
PREVENTER
BRASS 90 DEGREE ELLS (TYP.)
BRASS UNION (TYPICAL)
BACKFLOW PREVENTER UNIT
BRASS NIPPLES (TYPICAL)
COPPER SERVICE LINE
FINISH GRADE 1" BELOW PAD
BRASS COUPLING
1
6" MIN.
28" MIN.
3
30" MAX
12" MIN
(REFER TO LOCAL CODES)
4 5
6
7
8
12
11
13
10
1
2
3
4
5
6
7
8
10
11
12
13
3"
M
I
N
.
1"
9
PVC CONCRETE SLEEVE9
11
FL
O
W
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
Date:
Drawn By:
Project No:
Checked By:
H:
\
G
\
G
o
o
d
w
i
n
K
n
i
g
h
t
\
C
O
,
F
o
r
t
C
o
l
l
i
n
s
-
G
N
K
0
0
0
0
1
0
-
T
r
i
a
n
g
l
e
D
r
.
a
n
d
C
o
l
l
e
g
e
A
v
e
\
C
A
D
D
\
3
-
C
D
\
G
N
K
1
0
_
I
R
1
.
0
_
I
r
r
i
g
a
t
i
o
n
P
l
a
n
.
d
w
g
-
Er
i
c
N
e
w
e
l
l
-
6/
9
/
2
0
2
4
Init.#Issue / DescriptionDate
RI
D
G
E
W
O
O
D
H
I
L
L
S
-
F
I
F
T
H
F
I
L
I
N
G
FI
N
A
L
U
T
I
L
I
T
Y
P
L
A
N
FO
R
T
C
O
L
L
I
N
S
,
C
O
THESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
04.03.2024
GNK000010
JEP
DBC
PRE
L
I
M
I
N
A
R
Y
IRRIGATION NOTES &
DETAILS
IR-115
JR
EDN
DIRECT BURIAL CONTROL WIRES
POWER SWITCH
CONTROLLER MOUNTED IN VANDAL-
RESISTANT ENCLOSURE
VANDAL-RESISTANT ENCLOSURE PER
LEGEND
POWER WIRES IN CONDUIT. INSTALL
PER ALL APPLICABLE CODES
NOTE: CONTRACTOR SHALL PROVIDE
AND INSTALL AN EIGHT FOOT LONG
COPPER GROUNDING ROD INTO THE
GROUND FOR CONTROLLER. PROVIDE
PROPER INSTALLATION FOR
CONTROLLER PER MANUFACTURER
RECOMMENDATIONS.
1-1/2" CONDUIT FOR SENSOR AND
FLOW METER CABLE
2" PVC CONDUIT AND SWEEP WITH
CONTROL AND COMMON WIRES
CONCRETE BASE PER
MANUFACTURER'S SPECIFICATIONS
FINISH GRADE
1
2
3
4
5
6
7
8
9
3
5
6
7
8
9
2
1
4
NOTE:
MOUNT WHERE
SENSOR WILL BE
EXPOSED TO
UNOBSTRUCTED
RAINFALL, BUT
NOT IN PATH OF
SPRINKLER
SPRAY.
WEATHER SENSOR
EXTERIOR WALL OR POLE
1
1
2
2
FLOW
WATER METER PER LEGEND1 PVC FEMALE ADAPTER4
3
PVC MAINLINE PIPE5FINISHED GRADE2
6
2
3
5
4
1
6
CARSON VALVE BOX OR APPROVED
EQUAL. M BRAND ON LID.
3"
M
I
N
.
3" MINIMUM LAYER OF 3/4"
MINUS WASHED GRAVEL
PAVEMENT SURFACE
TRENCH BACKFILL
PVC MAINLINE SLEEVE SEEPLANS FOR SIZE
PVC LATERIAL SLEEVESEE PLANS FOR SIZE
LOCATOR WIRE WITHBURIED CAUTION TAPE IFSPECIFIED
PVC IRRIGATION MAINLINE
SLEEVING
TRENCHING
FINISH GRADE
PVC IRRIGATION LATERAL -BURIED MIN. 12" BELOWGRADE
SAND BACKFILL
2" MIN. PVC WIRE SLEEVEFOR CONTROL WIRES
NOTE:EXTEND SLEEVES INTOLANDSCAPE AREAS 12"BEYOND EDGE OFHARDSCAPE
2 3
1 3
10
512
"
M
I
N
.
18
"
M
I
N
.
12
"
M
I
N
.
18
"
M
I
N
.
4
6
789
1
2
3
4
5
6
7
8
9
10
NOTES:
1. MAXIMUM LENGTH OF SECONDARY WIRE PATH (14 AWG) FROM
DECODER TO RELAY IS 450 FEET.
2. PLACE 3-FEET OF EXTRA WIRE IN VALVE BOX FOR EASY SERVICING.
3. ALLOW MINIMUM DISTANCE OF 10X FLOW SENSOR SIZE FROM
NEAREST UPSTREAM VALVE, FITTING, OR REDUCING COUPLER FROM
EDGE OF FLOW SENSOR AND 5X SIZE FROM DOWNSTREAM EQUIPMENT.
1 2 3 4 5 6
7
8
91011101112
PVC MAINLINE PER PLAN
SENSOR DECODER PER PLAN
WIRES FROM THE FLOW SENSOR
SPLICED TO BLACK DECODER WIRES
FINISH GRADE
COMMUNICATION WIRE FROM DECODER
DBRY-6 WIRE CONNECTORS (4)
FLOW SENSOR PER PLAN
1
3
4
6
7
2
5
8
9
COMMUNICATION WIRE TO NEXT
DEVICE (FIELD DECODER, SENSOR
DECODER, LINE SURGE PROTECTOR
OR CONTROLLER)
TWO-WIRE CABLE WITH JACKET TO
NEXT DEVICE (FIELD DECODER,
SENSOR DECODER, LINE SURGE
PROTECTOR OR CONTROLLER)
10
11
GROUNDING WIRE12
CARSON VALVE BOX OR APPROVED
EQUAL. FS BRAND ON LID.
3" MINIMUM LAYER OF 3/4" MINUS
WASHED GRAVEL
3"
M
I
N
.
ID WIRES (36-INCH LOOP)
PREFORMED SUPER SERVISEAL
WATERPROOF WIRE SPLICE KIT
FINISH GRADE1
2
3
5
6
5 6
1
3
2
DBRY-6 WIRE CONNECTORS (4)
3" MINIMUM LAYER OF 3/4"
MINUS WASHED GRAVEL
FINISH GRADE
COPPER WIRE FOR
GROUNDING
DECODER PER PLAN
1
2
3
4
5
6
7
8
1
2
3 4 65
8
7 DBRY-6 WIRE
CONNECTORS (3)
TWO-WIRE CABLE WITH
JACKET TO NEXT
DEVICE (FIELD
DECODER, SENSOR
DECODER, LINE SURGE
PROTECTOR OR
CONTROLLER)
GROUNDING
CONNECTION
9
9 GROUND PLATE
FOR EARTH
GROUNDING
LINE SURGE PROTECTION SHOULD BE
INSTALLED EVERY 1,000 LF OR EVERY 12TH
DECODER AND AT THE END OF OR WIRE RUNS
WITH GROUNDING ROD, PLATE, AND 50LBS OF
EARTH CONTACT MATERIAL.
CARSON VALVE BOX OR
APPROVED EQUAL.
STATION NUMBER BRAND
ON LID.
3" MINIMUM LAYER OF 3/4"
MINUS WASHED GRAVEL
ELL CROSS
45° ELL
WYE
TEE
45° ELL
NOTES:1.PRESSURE SUPPLY LINES SIZE 2" AND LARGER SHALLRECEIVE CONCRETE THRUST BLOCKS.2.SEE SOILS ENGINEER FOR AMOUNT OF CONCRETE TOBE USED FOR THRUST BLOCK.
REBAR BENT AROUND FITTING
(TYPICAL)
PIPE (TYPICAL)
FITTING (TYPICAL)
CONCRETE THRUST BLOCK
(TYPICAL)
UNDISTURBED SOIL (TYPICAL)