Loading...
HomeMy WebLinkAboutLINDENMEIER ESTATE - BDR240012 - SUBMITTAL DOCUMENTS - ROUND 1 - Site PlanLI N D E N M E I E R R O A D E VINE DRIVE MAIN STREET Original Field Survey: EPS Group, Inc. Project No. 24-0350 Date: July 2024 AUGUST 2024 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH BENCHMARK: #1 City of Fort Collins 43-97 Elevation= 4960.11 On the South End of the West Headwall of the Lake Canal Bridge at the North Lemay Ave. , 200 feet South of the Intersection Basis of Bearings The east line of the Southeast Quarter of Section 1, as bearing North 0°33'39" East, with the Southeast Corner of said Section 1, Township 7 North, Range of 69 West P.M. PROJECT BENCHMARKS: 741 LINDENMEIER ROAD PROJECT TEAM: EPS Group, Inc. Amanda Poincelot 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE ENGINEER SHEET INDEX A PORTION OF THE SOUTHEAST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M. COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: EPS Group, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR BASIC DEVELOPMENT REVIEW USDA National Resources Conservation Service Custom Soil Report for 741 Lindenmeier Road Larimer County, Colorado Date: August 7, 2024 SUBSURFACE EXPLORATION BY: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. EPS Group, Inc. assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Cory Thelen (970) 225-7843 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowden (970) 416-2306 CABLE-------------Comcast----------------------------------Marcus Petty (720) 275-0572 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 1 COVER SHEET 2 EXISTING CONDITIONS/SITE PLAN 1 CO V E R S H E E T CS1 Sheet Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . NO T F O R C O N S T R U C T I O N RE V I E W S E T of 2 74 1 L I N D E N M E I E R R O A D FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 PROJECT LOCATION Meredith E. Glover PO Box 1295 Fort Collins, CO 80522 (303)931-3510 OWNER I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: City of Fort Collins, CO UTILITY PLAN APPROVAL APPROVED: CITY ENGINEER,APPROVED SHEETS DATE APPROVED: WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE APPROVED: STORMWATER UTILITY,APPROVED SHEETS DATE APPROVED: PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE APPROVED: TRAFFIC OPERATIONS,APPROVED SHEETS DATE APPROVED: ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE HYD W WV WV W W W W W W W WW W W XXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X G G G G G G G G G G G G G G G E E E E E E E C C C CABLE VAULT ELEC ELEC V.P. G EXISTING WATER LINE EXISTING GAS LINE EXISTING WATER VALVE EXISTING FIRE HYDRANT EXISTING RIGHT-OF-WAY EXISTING CENTERLINE EXISTING ELECTRICAL BOX SECTION LINE EXISTING ELECTRICAL BOX EXISTING ELECTRICAL LINE EXISTING FENCE EXISTING RIGHT-OF-WAY PROPOSED BUILDING ENVELOPE EXISTING WATER SERVICE LINE EXISTING GAS SERVICE LINE EXISTING COMMUNICATION LINE EXISTING COMMUNICATION PEDASTAL 20' FRONT SETBACK EXISTING DRIVEWAY ENTRANCE N0 0 ° 3 3 ' 3 8 . 6 2 " E 43 . 0 0 ' N89° 26' 21.38"W136.00' S89° 26' 21.38"E 136.00' 5' SIDE SETBACK 5' SIDE SETBACK 15' REAR SETBACK EXISTING CURB AND GUTTER S0 0 ° 3 3 ' 3 8 . 6 2 " W 43 . 0 0 ' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH EX1 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING GAS METER EXISTING TELEPHONE PEDESTAL FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING CABLE VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT CABLE 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 3.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. EPS Group, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970)221-4158 C EXISTING ELECTRICAL BOX ELEC EXISTING CENTERLINE EXISTING SECTION LINE Sheet Th e s e d r a w i n g s a r e in s t r u m e n t s o f s e r v i c e pr o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . an d a r e n o t t o b e u s e d f o r an y t y p e o f c o n s t r u c t i o n un l e s s s i g n e d a n d s e a l e d b y a P r o f e s s i o n a l E n g i n e e r i n th e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . NO T F O R C O N S T R U C T I O N RE V I E W S E T of 2 74 1 L I N D E N M E I E R R O A D FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP W 2 EX I S T I N G C O N D I T I O N S EX1 ( IN FEET ) 010 10 20 30 1 INCH = 10 FEET City of Fort Collins, CO UTILITY PLAN APPROVAL APPROVED: CITY ENGINEER,APPROVED SHEETS DATE APPROVED: WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE APPROVED: STORMWATER UTILITY,APPROVED SHEETS DATE APPROVED: PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE APPROVED: TRAFFIC OPERATIONS,APPROVED SHEETS DATE APPROVED: ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE MINIMUM ACTUAL LOT AREA 6000 FT 5848 SQ FT LOT WIDTH 60 FT 48 FT FRONT SETBACK 20 FT 20 FT REAR SETBACK 15 FT 15 FT SIDE SETBACK 5 FT 5 FT ZONING LOW DENSITY RESIDENTIAL DISTRICT (RL) BUILDING TYPE ALLOWED DETACHED HOUSE (URBAN & SUBURBAN) # OF UNITS 1 MAX SINGLE UNIT DWELLING BUILDING HEIGHT 28 FT MAX *SEE CITY OF FORT COLLINS LANDUSE CODE ARTICLE 2.1.4, ARTICLE 3.1.6, ARTICLE 3.1.7 & ARTICLE 4 FOR ADDITIONAL REQUIREMENTS