HomeMy WebLinkAboutBLOOM FILING SIX - PDP230017 - SUBMITTAL DOCUMENTS - ROUND 3 - Site, Landscape & Elevations Plans1 OF 7
980 Norway Maple Drive
MIC TDC Mulberry St
401 Linden Street Unit 1-401
Fort Collins, CO 80524
970-215-9183
ET RM
-12/19/2023
Loveland, CO 80538
970-988-5301
VICINITY MAP
N.T.S.
BLOOM FILING SIX
PROJECT DEVELOPMENT PLAN
OWNER'S CERTIFICATE
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL
OWNERS OF REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY
CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON
SAID PROJECT DEVELOPMENT PLAN WITHIN THE LIMIT OF DEVELOPMENT
BOUNDARY.
OWNER (Signed) DATE
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME ON THIS DAY,
BY:
(Print Name)
AS
MY COMMISSION EXPIRES:
WITNESS MY HAND AND OFFICIAL SEAL.
NOTARY PUBLIC ADDRESS
SITE
NW
F
R
O
N
T
A
G
E
R
D
E. MULBERRY ST
Submittal 1 12/20/23
IN
T
E
R
S
T
A
T
E
2
5
N
B
MIC TDC MULBERRY ST FORT COLLINS
LLC
DEAN BARBER
8840 LONGS PEAK CIRCLE WINDSOR,
CO 80550 DBARBER@TDC-DEV.COM
970.215.9183
Planscapes Design Group
980 Norway Maple Drive
Loveland, CO 80538
303-585-1055
970-988-5301
DATEDESCRIPTIONREV
FRONTAGE RD N DE
L
O
Z
I
E
R
D
R
MIC TDC Mulberry St Fort Collins, LLC
401 Linden Street, Unit 1-401
Fort Collins, CO 80524
970-215-9183
i2 Consultants
Troy Campbell
16911 Potts Place
Mead, CO 80542
970-217-9148
Majestic Surveying
Steven Parks
1111 Diamond Valley Dr #104
Windsor, CO 80550
970-833-5698
PLANNING CERTIFICATE
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND
NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS
DAY,
DIRECTORS SIGNATURE
Fort Collins, LLC
Submittal 2 05/14/24
"Lots One through Four, as shown on the Bloom Filing Six Project
Development Plan, are designated as "Future Development" and eligible for
any of the permitted uses as defined by District 4 of the Mulberry & Greenfields PUD.
Subsequent development of each building will require City approval as a
Minor or Major Amendment and site specific utility plans (prepared by a
licensed engineer in the State of Colorado for the area surrounding each
building). Said Amendment shall be considered in a separate but complete
application including site plan, landscape plan, architectural elevations, lighting
plan, drainage report, and any other plans or reports as may be required,
individual pad development shall also include financial obligations such as
application fees, erosion control deposits, and inspection fees. A Development
Agreement between the City and the Parcel developer may be required on a per pad
basis."
"All building shall utilize a consistent architectural style, with different buildings,
businesses or activities in the center distinguished by variations within the
architectural style. Standardized architecture recognized as a prototype of a
larger chain of establishments shall be customized as necessary to express a
level of quality that enhances the distinctive character of the Mulberry &
Greenfields PUD and the city as a whole."
CONCEPTUAL SITE PLAN NOTES:
Submittal 3 08/28/24
18. PHOTOMETRIC PLANS WILL BE PROVIDED AS PART OF A FUTURE MINOR AMENDMENT OR
MAJOR AMENDMENT TO THE PLAN.
OUTLOT A
67,203 SQ. FT.
1.543 ACRES
TRACT A
10,855 SQ. FT.
0.249 ACRES
OUTLOT ALOT 2
34,932 SQ. FT.
0.802 ACRES
LOT 1
49,130 SQ. FT.
1.128 ACRES
LOT 4
49,524 SQ. FT.
1.137 ACRES
LOT 3
26,190 SQ. FT.
0.601 ACRES
Submittal 1 12/20/23
2 OF 7
980 Norway Maple Drive
MIC TDC Mulberry St
401 Linden Street Unit 1-401
Fort Collins, CO 80524
970-215-9183
RM
-12/19/2023
Loveland, CO 80538
970-988-5301
BLOOM FILING SIX
PROJECT DEVELOPMENT PLAN
Fort Collins, LLC
LEGEND
EASEMENT
PROPERTY BOUNDARY
PROPOSED LOT LINES
NORTH
8020040
SCALE: 1" = 40'
REV DESCRIPTION DATE
NATURAL HABITAT BUFFER ZONE
Submittal 2 05/14/24
Submittal 3 08/28/24
PAVEMENT
OUTLOT A
67,203 SQ. FT.
1.543 ACRES
TRACT A
10,855 SQ. FT.
0.249 ACRES
OUTLOT ALOT 2
34,932 SQ. FT.
0.802 ACRES
LOT 1
49,130 SQ. FT.
1.128 ACRES
LOT 4
49,524 SQ. FT.
1.137 ACRES
LOT 3
26,190 SQ. FT.
0.601 ACRES
POINT OF CONNECTION
BACKFLOW PREVENTER
IRRIGATION SLEEVE
IRR
I
G
A
T
I
O
N
S
L
E
E
V
E
NORTH
8020040
SCALE: 1" = 40'
PLANT LEGEND
NATIVE GRASS
DETENTION BASIN GRASS MIX
PAVEMENT
POLLINATOR RESOURCES ARE
EXISTING TREES
ORNAMENTAL TREES
DECIDUOUS CANOPY TREES
PLANT LIST
Submittal 1 12/20/23
3 of 7
980 Norway Maple Drive
MIC TDC Mulberry St
401 Linden Street Unit 1-401
Fort Collins, CO 80524
970-215-9183
ET RM
-12/19/2023
Loveland, CO 80538
970-988-5301
BLOOM FILING SIX
PROJECT DEVELOPMENT PLAN
Fort Collins, LLC
DATEDESCRIPTIONREV
KEY BOTANICAL NAME COMMON NAME SIZE NOTES
DECIDUOUS TREES
ORNAMENTAL TREES
B+BMalus 'Spring Snow'Spring Snow CrabappleMSS 1.5" cal.
B+B2" calGymnocladus dioicus Kentucky Coffee TreeGD
B+B2" calCatalpa speciosa Western CatalpaCS
B+BGinkgo biloba 'Princeton Sentry'Princeton Sentry Columnar Ginkgo TreeGB 1.5" cal.
B+B2" calCeltis occidentalis Western HackberryCO
B+B2" calUlmus x 'Morton'Accolade ElmAE
NATURAL HABITAT BUFFER ZONE
IRRIGATED TURF
NOTE:
THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1
OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE.
POLLINATORS PLANT LIST
KEY BOTANICAL NAME COMMON NAME SIZE NOTES
DECIDUOUS SHRUBS
PERENNIAL POLINTORS
1 galMoonsAchillea moonshine Moonshine YarrowAM 18"-24"
5 gal4'-5'Mahonia aquifolium Oregon Grape HollyMA
5 gal4'-5'Amorpha canescens LeadplantAC
1 gal.Schizachyrium scoparium Prairie Blues Little Bluestem Prairie BluesSSPB 2'-3'
5 gal4'-6'Chamaebatiaria millfolium FernbushCM
5 gal8'-12'Forestiera neomexicana New Mexico PrivetFN
1 galAgastache pallida Giant Hummingbird MintAP 2'-3'
1 gal.Asclepias incarnata 'Cinderella'Cinderella Butterfly WeedAL 3'-5'
B+BQuercus robur 'Fastigiata'Columinar English OakGB 1.5" cal.
EVERGREEN TREES
EVERGREEN TREES
B+BPinus edulis Pinyon PinePE 8' ht
Submittal 3 08/28/24
LEGEND/ANNUAL WATER NEEDS
92% LOW WATER ZONE
80,466sf x 7gal.= 563,262 gallons annually
8% HIGH WATER ZONE
4,662 sf x 18gal. = 50,040 gallons annually
TOTAL 613,302 gallons annually
OVERALL SITE USE = 4.7gal/sf
General Landscape Notes
1.PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE • FREE OF ANY DEFECTS, OF NORMALHEALTH, HEIGHT, LEAF DENSITY ANO SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICANASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL ANO BURLAP OR EQUIVALENT.
2.IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS ANO TREE AREAS SHALL BEIRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVEDBY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT.ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS ANOTREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATIONSYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THEIRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANTMATERIAL
3.TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTMTYSHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING.
4.SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED ANO DOCUMENTED IN ACCORDANCE WITH CITY CODESECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BETHOROUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(S) INCHES ANO SOIL AMENDMENT SHALL BETHOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHESBY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RA TE OF AT LEAST THREE (3) CUBIC YARDS OF SOILAMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANYCERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTEDAREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED ANO THE SOIL AMENDED, CONSISTENTWITH THE REQUIREMENTS SET FORTH IN SECTION 12-132.
5. INSTALLATION ANO GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUNDHORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT ANO HEAL THYGROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BESECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BONO, OR ESCROW ACCOUNT FOR 125% OFTHE VALUATION OF THE MATERIALS AND LABOR PR.IOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANYBUILDING IN SUCH PHASE.
6.MAINTENANCE: TREES ANO VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS ANO OTHER LANDSCAPEELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAMEMANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER ORSUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCEOF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROMDISEASE, PESTS, WEEDS ANO LITTER, ANO ALL LANDSCAPE STRUCTURES SUCH AS FENCES ANO WALLS SHALL BEREPAIRED ANO REPLACED PERIOOICALL Y TO MAINTAIN A STRUCTURALLY SOUND CONDITION.
7.REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLYREPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.
8.THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS ANO UTILITIES:
40 FEET BETWEEN CANOPY TREES ANO STREET LIGHTS15 FEET BETWEEN ORNAMENTAL TREES ANO STREETLIGHTS10 FEET BETWEEN TREES ANO PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES6 FEET BETWEEN TREES ANO PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.4 FEET BETWEEN SHRUBS AND PUBLIC WATER ANO SANITARY ANO STORM SEWER LINES4 FEET BETWEEN TREES ANO GAS LINES
9.ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS ANDALLEYS PER LUC 3.2.1(0)(2Xa).
10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIEDBY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BEALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXC-EPTION OF DECIDUOUS TREESPROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCETRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT ANO OF AN OPEN DESIGN.
11.THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THEPROPOSED GRADING, STORM DRAINAGE, ANO OTHER DEVELOPMENT IMPROVEMENTS 00 NOT CONFLICT WITHNOR PRECLUDE INSTALLATION ANO MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.
12.MINOR CHANGES IN SPECIES ANO PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -AS REQUIRED BYSITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, ANO DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THEPLANT LIST, SPECIES ANO QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES ANDLOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.
13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.
NOTE. CEDAR MULCH TREE RING SHALL BE36"0IA.
CEDAR MULCH RING TO BE TWICE DIAMETER OF ROOT BALL . 2" DEPTH
KEEP MULCH LAYER AWAY FROM FOLIAGE
✓ / L l EXISTING__/ ; PLANTING HOLE-.SOIL TO BE 6" LARGER THAN DIA. OF SECTION ROOT8ALL FOR GROUNOCOVER. 12" LARGER THAN DIA OF ROOTBALL FOR SHRUBS
TOP OF ROOT CROWN TO BE 1· HIGHER THAN FINISH GRADE MULCH. SEE NOTES. 5· DEPTH MAXIMUM
OPEN BURLAP AROUND TRUNK. CUT & REMOVE TOP 113 OF BURLAP SLOW RaEASE FERTILIZER TABLET (TYP.) BACKFILL W/2/3 NATIVE SOIL & 113 COMPOST, ll10ROUGHL Y WATER SETTlE
z i <o TREE TRUNK--tt---•-t,j 2"MULCH
12" MIN.
12" MIN.,24" GREATER TYP. -l'-='TH""'A"'"N".cD"'c lA;.,.. ""oF=-,!<,'ROOTBALL SECTION
BLOOM FILING 6
PROJECT DEVELOPMENT PLAN
BEING A REPLA T OF TRACT II, BLOOM FILING ONE,
SITUATE IN THE SOUTHWEST QUARTER OF SECTION 9, TOWNSHIP 7 NORTH,
RANGE 68 WEST OF THE 6TH P.M.
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Street Tree Notes
1.A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THISPLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEENTHE SIDEWALK ANO CURB, MEDIANS ANO OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATIONANO SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINSCODE SUBJECT TO CITATION (SECTION 27-31) ANO MAY ALSO RESULT IN REPLACING OR RELOCATING TREESANO A HOLD ON CERTIFICATE OF OCCUPANCY.
2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACHPHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OFSTREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE.
3.STRE.ET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITYCODES AND POLICIES. ALL TREE PRUNING ANO REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORTCOLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED ANO PLANTED BYTHE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR.
4.THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCEINSPECTION ANO ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THEPROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES ANO OF ACCEPTABLE CONDITION PRIOR TOACCEPTANCE.
5.SUBJECT TO APPROVAL BY THE CITY FORESTER -STREET TREE LOCATIONS MAY BE ADJUSTED TOACCOMMODATE ORJVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREETLIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIESSHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATIONSTANDARDS.
A PERMIT MUST BE OBTAINED FROM fHE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT .OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK ANO CURB, MEDIANS ANO OTHER CITY PROPERTY THIS PERMIT SHALL APPROVE THE LOCATION ANO SPECIES TO BE PLANTED, FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31)ANO MA\ ALSO RESULT IN REPLACING OR RELOCATING TREES ANO A HOLD ON CERTIFICATE OF OCCUPANCY.
NOTE: THE WIRE BETWEEN THE STAKE ANO THE TREE MUST HAVE SLACK [ WIRE,TYP.
T-POST
NOTE. CEDAR MULCH TREE RING SHAU BE 36" DIA.
TOP OF ROOT CROWN TO BE 1" HIGHER THAN FINISH GRADE 2"MULCH
WIRE. TYP
Tree Protection Notes
1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT ANO WITHIN ANY NATIJRAL AREA BUFFERZONES SHALL REMAIN ANO BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.
2.WITHIN THE ORJP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER AFOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED ANO APPROVED THEDISTURBANCE.
3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY ST ANOAROS.TREE PRUNING ANO REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORTCOLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.
4.PRIOR TO ANO DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTINGTREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECUREDWITH MET AL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE,WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS ORFILL WITHIN THE FENCED TREE PROTECTION ZONE.
5.
6,
7.
8.
DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OFEQUIPMENT OR MATERIAL OR THE STORAGE ANO DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS,SOL VENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREEWITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
LARGE PROPERTY AREAS CONTAINING PROTECTED TREES ANO SEPARATED FROM CONSTRUCTION OR LANOCLEARING AREAS, ROAD RIGHTS.OF-WAY ANO UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THANERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BEACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART ANO TYING RIBBONOR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED.
THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTIJRE REQUIRING EXCAVATIONDEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTEDEXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHEDFROM THE FACE OF THE TREE (OUTER BARK) ANO IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT ASDESCRIBED IN THE CHART BELOW:
TREE DIAMETER AT BREAST HEIGHT (!!'!CHE_§) FACE OF TREE (FEET)
0-2
3-4
5-9
10-14
15-19
OVER 19
AUGER DISTANCE FROM
1
2
5
10
12
15
9."NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUTFIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. THE SURVEY SHALL BE SENT TO THE CITYENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE FOUND, THE CITY WILL COORDINATE WITH RELEVANT STATEANO FEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL ANO CONSTRUCTION APPLY.•
NOTE. THE WIRE BETWEEN THE STAKE ANO THE TREE MUST HAVE SLACK
GROMMETED NYLON STRAP, TYP. TIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE WIRE ENDS SHALL BE BENT BACK TO ELIMINATE BURRS AND WHITE PVC PIPE ALONG ENTIRE LENGTH OF WIRE FOR VISUAL AND SAFETY TOP OF ROOT CROWN TO BE 1· HIGHER THAN FINISH GRADE DRIVE THREE (3) T-POSTS PER TREEFOR TREES OVER 6' IN HEIGHT DRIVE TWO (2) T-POSTS FOR TREES6' IN HEIGHT OR LESS. SPACE i.\a.l I ANCHORS EQUAU Y AROUND TRUNK. :ft� I AVOID DAMAGE TO BRANOI ES,
�- GROMM ETED NYLON STRAP. TYP.
TIE GROMMETED NYLON STRAPS TO STAKE WITH WIRE. WIRE ENOS SHALL BE BENT BACK TO ELIMINATE BURRS ANO WHITE PVC PIPE Al.ONG ENTIRE LENGTH OF WIRE FOR VISUAL ANO SAFETY TOP OF ROOT CROWN TO BE 1· HIGHER THAN FINISH GRADE DRIVE TWO (2) T-POST STAKES PER T REE.
" REMOVE WIRE CAGE ANO/OR TWINE. AND BURLAP . SLOW RELEASE FERTILIZER TABLET (TYP,) BACKFILL W/ 2/3 NATIVE SOIL & 113 COMPOST. THOROUGHLY WATER SETTLE EXISTING SOIL
NOTE. WIRE BASKETS ANO TWINE SHALL BE COMPLETELY REMOVED PRIOR TO TREE INSTAUATION.
'VVVV.� - REMOVE WIRE CAGE ANO/OR TWINE. AND BURLAP�, "'
12" MIN. • ' "--SLOW RELEASE FERTILIZER TABLET (T YP.)18" MIN., 24" GR EATER TYP , . ..J!-->.-J<.'T;;;HAN,.;;;.;_,;o::.;1 A"'o;:,F;....,11-ROOTBALL SECTION
�-BACKFILL W/213 NATIVE SOIL & 113 COMP OST. THOROUGHLY WATER SETTLE EXISTING SOIL
NOTE. WIRE BASKETS ANO TWINE SHALL BE COMPLETELY REMOVED PRIOR TO TREE INSTALLATION.
GROUND COVER & SHRUB PLANTING DETAIL DECIDUOUS TREE PLANTING DETAIL CONIFER TREE PLANTING DETAIL
PLANSCAPES DESIG>I GROUP
LANO Pt.ANNINGJ LANDSCAPE ARCttlTECTUAE
980 Norway Maple Drive
Loveland, CO 80538
970-988-5301
PROJECT NAME:
BLOOM FILING 5
ORA �NG TITLE:
LANDSCAPE DETAILS
[��� BY ] CHECKED BY:
RM
DATE: [ APPR0\£0 �y ] 12/19/2023
CLIENT
MIC TDC Mulberry St
Fort Collins, LLC
401 linden Street Unit l -40 l
Fort Collins, CO 80524
970-2 15-9 l 83
REV DESCRIPTION
Submittal 1
Submittal 2
SHEET NO:
4 OF 7
DATE
12/20/23
05/14/24
NORTH
8020040
SCALE: 1" = 40'
Submittal 1 12/20/23
5 of 7
980 Norway Maple Drive
MIC TDC Mulberry St
401 Linden Street Unit 1-401
Fort Collins, CO 80524
970-215-9183
ET RM
-12/19/2023
Loveland, CO 80538
970-988-5301
BLOOM FILING SIX
PROJECT DEVELOPMENT PLAN
Fort Collins, LLC
DATEDESCRIPTIONREV
NATIVE SEED MIX NOTES
1.THE TIME OF YEAR SEEDING IS TO OCCUR SHOULD BE OCTOBER
THROUGH EARLY MAY.
2.PREPARE SOIL AS NECESSARY AND APPROPRIATE FOR NATIVE
SEED MIX SPECIES THROUGH LOOSENING AND ADDITION OF
AMENDMENTS THAT PROMOTE WATER ABSORPTION AND RELEASE,
THEN SEED IN TWO DIRECTIONS TO DISTRIBUTE SEED EVENLY OVER
ENTIRE AREA. DRILL SEED ALL INDICATED AREAS AS SOON AS
POSSIBLE AFTER COMPLETION OF GRADING OPERATIONS.
3.IF CHANGES ARE TO BE MADE TO SEED MIX BASED ON SITE
CONDITIONS THEN APPROVAL MUST BE PROVIDED BY CITY
ENVIRONMENTAL PLANNER.
4.APPROPRIATE NATIVE SEEDING EQUIPMENT WILL BE USED
(STANDARD TURF SEEDING EQUIPMENT OR AGRICULTURE EQUIPMENT
SHALL NOT BE USED).
5.DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED
APPLICATION RATE TO NO MORE THAN ½ INCH DEPTH. FOR
BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD DOUBLE
SPECIFIED APPLICATION RATE. REFER TO NATIVE SEED MIX TABLE
FOR SPECIES, PERCENTAGES AND APPLICATION RATES.
6.PREPARE A WEED MANAGEMENT PLAN TO ENSURE THAT WEEDS
ARE PROPERLY MANAGED BEFORE, DURING AND AFTER SEEDING
ACTIVITIES.
7.AFTER SEEDING THE AREA SHALL BE COVERED WITH CRIMPED
STRAW, JUTE MESH, OR OTHER APPROPRIATE METHODS.
PLASTIC_BASED EROSION CONTROL MATERIALS (I.E.,
PLASTIC_WELDED BLANKETS) SHALL NOT BE USED WITHOUT
EXPRESS PERMISSION FROM THE ENVIRONMENTAL PLANNER AS
THESE MATERIALS HAVE PROVEN TO CAUSE WILDLIFE ENTRAPMENT
ISSUES.
8.WHERE NEEDED, TEMPORARY IRRIGATION SHOULD BE PROVIDED
UNTIL SEED IS GERMINATED THEN WEEN THE SEED FROM IRRIGATION.
IF IRRIGATION IS USED, THE IRRIGATION SYSTEM FOR SEEDED AREAS
SHALL BE FULLY OPERATIONAL AT THE TIME OF SEEDING AND SHALL
ENSURE 100% HEAD_TO_HEAD COVERAGE OVER ALL SEEDED AREAS.
ALL METHODS AND REQUIREMENTS IN THE APPROVED IRRIGATION
PLAN SHALL BE FOLLOWED.
9.CONTRACTOR SHALL MONITOR SEEDED AREA FOR PROPER
IRRIGATION, EROSION CONTROL, GERMINATION AND RESEEDING AS
NEEDED TO ESTABLISH COVER.
10.THE APPROVED NATIVE SEED MIX AREA IS INTENDED TO BE
MAINTAINED IN A NATURAL LIKE LANDSCAPE AESTHETIC. DO NOT
MOW DURING HOT, DRY PERIODS. DO NOT MOW LOWER THAN 6 TO 8
INCHES IN HEIGHT TO AVOID INHIBITING NATIVE PLANT GROWTH.
11.NATIVE SEED AREA WILL BE CONSIDERED ESTABLISHED WHEN
SEVENTY PERCENT VEGETATIVE COVER IS REACHED WITH LESS
THAN TEN PERCENT OF COVER CONSISTING OF NOXIOUS WEEDS, NO
BARE SPOTS LARGER THAN ONE FOOT SQUARE, AND/OR UNTIL
DEEMED ESTABLISHED BY CITY PLANNING SERVICES AND EROSION
CONTROL.
12.THE DEVELOPER AND/OR LANDSCAPE CONTRACTOR IS
RESPONSIBLE FOR ADEQUATE SEEDLING COVERAGE AND GROWTH
AT THE TIME OF FINAL STABILIZATION, AS DEFINED BY STATE AND
LOCAL AGENCIES. IF FINAL STABILIZATION IS NOT ACHIEVED TO THE
SATISFACTION OF THE AGENCY, THE DEVELOPER AND/OR
LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL
CORRECTIVE MEASURES TO SATISFY FINAL VEGETATIVE
REQUIREMENTS FOR CLOSEOUT.
Upland Restoration Plan
This upland restoration plan encompasses portions of the project area to be revegetated
with native upland vegetation. This includes contoured and graddedareas and the Natural
Habitat Buffer Zone (NHBZ) ecological restoration areas. This plan does not include
landscaped areas. Note: This upland restoration plan includes areas immediately
adjacent to bioretention swales. The actual timing of project implementation is
unknown, so only general temporal guidelines are provided. This plan includes
guidelines for exotic grass and noxious weed management, soil treatment, planting of
cover crop and native vegetation, erosion control, monitoring, irrigation, and
maintenance of the seeded areas. Table 1 outlines restoration activities for each year.
Submittal 3 8/28/24
FRONT ELEVATION
SCALE: N.T.S.
REAR ELEVATION
SCALE: N.T.S.
SIDE ELEVATION
SCALE: N.T.S.
FRONT ELEVATION
SCALE: N.T.S.
REAR ELEVATION
SCALE: N.T.S.
SIDE ELEVATION
SCALE: N.T.S.
FRONT ELEVATION
SCALE: N.T.S.
REAR ELEVATION
SCALE: N.T.S.
SIDE ELEVATION
SCALE: N.T.S.
FRONT ELEVATION
SCALE: N.T.S.
SIDE ELEVATION
SCALE: N.T.S.
CAR WASH
RESTAURANT, FAST FOOD W/ DRIVE THRU
SMALL FORMATE RESTAURANT, FAST FOOD W/ DRIVE THRU
RETAIL ESTABLISHMENT
SIDE ELEVATION
SCALE: N.T.S.
PROVIDE A CLEARLY
DEFINED ENTRY FEATURE
THAT IS DIFFERENTIATED
BY ITS HEIGHT, MATERIAL
& MASSING
USE MATERIALS, BUILDING
SET-BACKS, AND FEATURES
TO BREAK THE HORIZONTAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, HORIZONTAL
BANDING, AND FEATURES
TO BREAK THE VERTICAL
DESIGN ALONG EACH ELEVATION
FRONT FACADES TO UTILIZE
STOREFRONT GLAZING SYSTEMS
TO ENHANCE THE FRONT FACADE
AND MEET THE TRANSPARENCY
REQUIREMENTS
USE OF 3 OR MORE
MATERIALS IS ENCOURAGED
TO ADD INTEREST TO THE
DESIGN. STONE, BRICK, STUCCO
AND METAL PANEL PREFERRED
METAL AND WOOD
AWNINGS AND SHADING
DEVICES ARE ENCOURAGED
TO ADD INTEREST AND SPEAK
TO THE COLORADO
CONTEMPORARY DESIGN STYLE
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
USE BRICK OR
CMU AS A PRIMARY
OR SECONDARY
MATERIAL
USE BRICK OR
CMU AS A PRIMARY
OR SECONDARY
MATERIAL
USE ASPHALT
SHINGLES FOR ANY
SLOPED ROOF
CONDITIONS
USE ASPHALT
SHINGLES FOR ANY
SLOPED ROOF
CONDITIONS
FRONT FACADES TO UTILIZE
STOREFRONT GLAZING SYSTEMS
TO ENHANCE THE FRONT FACADE
AND MEET THE TRANSPARENCY
REQUIREMENTS
FRONT FACADES TO UTILIZE
STOREFRONT GLAZING SYSTEMS
TO ENHANCE THE FRONT FACADE
AND MEET THE TRANSPARENCY
REQUIREMENTS
PROVIDE A CLEARLY
DEFINED ENTRY FEATURE
THAT IS DIFFERENTIATED
BY ITS HEIGHT, MATERIAL
& MASSING
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
USE MATERIALS, HORIZONTAL
BANDING, AND FEATURES
TO BREAK THE VERTICAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, HORIZONTAL
BANDING, AND FEATURES
TO BREAK THE VERTICAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, HORIZONTAL
BANDING, AND FEATURES
TO BREAK THE VERTICAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, BUILDING
SET-BACKS, AND FEATURES
TO BREAK THE HORIZONTAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, BUILDING
SET-BACKS, AND FEATURES
TO BREAK THE HORIZONTAL
DESIGN ALONG EACH ELEVATION
FRONT FACADES TO UTILIZE
STOREFRONT GLAZING SYSTEMS
TO ENHANCE THE FRONT FACADE
AND MEET THE TRANSPARENCY
REQUIREMENTS
PROVIDE A CLEARLY
DEFINED ENTRY FEATURE
THAT IS DIFFERENTIATED
BY ITS HEIGHT, MATERIAL
& MASSINGUSE MATERIALS, BUILDING
SET-BACKS, AND FEATURES
TO BREAK THE HORIZONTAL
DESIGN ALONG EACH ELEVATION
USE MATERIALS, BUILDING
SET-BACKS, AND FEATURES
TO BREAK THE HORIZONTAL
DESIGN ALONG EACH ELEVATION
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL
USE EIFS AS A
PRIMARY OR
SECONDARY
MATERIAL
USE EIFS AS A
PRIMARY OR
SECONDARY
MATERIAL
USE EIFS AS A
PRIMARY OR
SECONDARY
MATERIAL
USE EIFS AS A
PRIMARY OR
SECONDARY
MATERIAL
USE EIFS AS A
PRIMARY OR
SECONDARY
MATERIAL
PROVIDE A CLEARLY
DEFINED ENTRY FEATURE
THAT IS DIFFERENTIATED
BY ITS HEIGHT, MATERIAL
& MASSING
FRONT FACADES TO UTILIZE
STOREFRONT GLAZING SYSTEMS
TO ENHANCE THE FRONT FACADE
AND MEET THE TRANSPARENCY
REQUIREMENTS
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL, COLOR:
SUNSET STONE, COUNTRY
LEDGE OR SIMILAR
PRIMARY BUILDING ENTRANCES
SHALL BE CLEARLY DEFINED AND
RECESSED OR FRAMED BY A
SHELTERING ELEMENT SUCH AS
AN AWNING IN ORDER TO PROVIDE
SHELTER FROM THE SUMMER
SUN AND WINTER WEATHER
THREE-DIMENSIONAL
CORNICE TREATMENT
COLOR: SHERWIN
WILLIAMS SW7019
GAUNTLET GREY
OR SIMILAR
STONE WITH
SILL TO PROVIDE
RECOGNIZABLE BASE
TREATMENT
ALUMINUM STORE-
FRONT WINDOW
SYSTEM, COLOR:
DARK BRONZE OR
SIMILAR
STUCCO OR OTHER
HIGH QUALITY MATERIAL
COLOR: SHERWIN WILLIAMS,
SW6155 RICE GRAIN OR SIMILAR
ALUMINUM STORE-
FRONT WINDOW
SYSTEM, COLOR:
DARK BRONZE OR
SIMILAR DARK COLOR
MATERIAL EXAMPLES
EXAMPLE STONE:
SUNSET STONE
COLOR: COUNTRY
LEDGE OR SIMILAR
EXAMPLE STUCCO
COLOR:
SHERWIN WILLIAMS
COLOR: SW6155
RICE GRAIN OR
SIMILAR
EXAMPLE STUCCO
COLOR:
SHERWIN WILLIAMS
COLOR: SW7019
GAUNTLET GRAY OR
SIMILAR
STOREFRONT
WINDOWS
COLOR: KAWNEER
COLOR: DARK BRONZE
ANODIZED OR
SIMILAR
STUCCO OR OTHER
HIGH QUALITY MATERIAL
COLOR: SHERWIN WILLIAMS,
SW6155 RICE GRAIN OR SIMILAR
CULTURED STONE
OR BRICK A PRIMARY
OR SECONDARY
MATERIAL, COLOR:
SUNSET STONE, COUNTRY
LEDGE OR SIMILAR Seal:
SDP SET
Issued For SD:
Issued For DD:
Issued For Permit:
Issued For Construction:
00/00/2015
00/00/2015
00/00/2015
00/00/2015
Revision Number Revision Date
Plot Date: August 28, 2024
A01
EX
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
CO
N
C
E
P
T
S
CO
N
C
E
P
T
B
U
I
L
D
I
N
G
E
L
E
V
A
T
I
O
N
S
206 E 4th Street Sute 250, Loveland, Colorado 80537
ARCHITECTS
BL
O
O
M
R
E
T
A
I
L
DE
V
E
L
O
P
M
E
N
T
infusion
EA
S
T
F
R
O
N
T
A
G
E
R
D
(
C
O
1
4
)
,
F
O
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
OUTLOT A
67,203 SQ. FT.
1.543 ACRES
TRACT A
10,855 SQ. FT.
0.249 ACRES
OUTLOT ALOT 2
34,932 SQ. FT.
0.802 ACRES
LOT 1
49,130 SQ. FT.
1.128 ACRES
LOT 4
49,524 SQ. FT.
1.137 ACRES
LOT 3
26,190 SQ. FT.
0.601 ACRES
POINT OF CONNECTION
BACKFLOW PREVENTER
IRRIGATION SLEEVE
IRR
I
G
A
T
I
O
N
S
L
E
E
V
E
Submittal 1 12/20/23
7 OF 7
980 Norway Maple Drive
MIC TDC Mulberry St
401 Linden Street Unit 1-401
Fort Collins, CO 80524
970-215-9183
RM
-12/19/2023
Loveland, CO 80538
970-988-5301
BLOOM FILING SIX
PROJECT DEVELOPMENT PLAN
Fort Collins, LLC
NORTH
8020040
SCALE: 1" = 40'
REV DESCRIPTION DATE
Submittal 2 05/14/24
Submittal 3 08/28/24
1803 WITH SWING JOINT
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS.
REFERENCE NUMBER 045-081.
3. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info
WITH RAIN BIRD ROTARY NOZZLE
WITH 1800 VPC
7
POP-UP SPRAY SPRINKLER:
RAIN BIRD 1802
PVC SCH 40 TEE OR ELL
FINISH GRADE/TOP OF MULCH
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
PVC SCH 40 ELL
PVC SCH 40 STREET ELL
PVC LATERAL PIPE
4
6
1
5
2
3
5 73
6
5
4
3
2
1
D
FLOW
DRIP LINE FILTER AND PRESSURE REDUCER
5505 (N.T.S.)
DRIP EMITTER
5505 (N.T.S.)
A
B
1.THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE
FOR THE IRRIGATION SYSTEM OF 40 PSI. AT A MAXIMUM
DISCHARGE OF 55 GPM AT THE IRRIGATION POINT OF CONNECTION
1 (POC1) VERIFY PRESSURE AND GLOW ON SITE PRIOR TO
CONSTRUCTION.
2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE
SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND
RELATED WORK PRIOR TO CONSTRUCTION.
3.COORDINATE UTILITY LOCATES (CALL BEFORE YOU DIG)
4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION
SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTION OR
GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN
CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN
CONSTRUCTION DETAILS, LEGEND, NOTES, OR DISCREPANCIES TO
THE ATTENTION OF THE OWNERS REPRESENTATIVE.
5.THE DRAWING ARE DIAGRAMMATIC. THEREFORE THE FOLLOWING
SHOULD BE NOTED.
A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE
PLANTING AREAS FOR CLARITY' INSTALL IRRIGATION PIPE AND
WIRING IN THE LANDSCAPED AREAS WHENEVER POSSIBLE.
B.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS
TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS.
AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING
MATERIALS, AND ARCHITECTURAL FEATURES.
C.USE ONLY STANDARD TEE AND ELBOW FITTINGS. USE OF TEE
FITTINGS IN THE BULL-NOSE CONFIGURATION, OR USE OF CROSS
TYPE FITTINGS IS NOT ALLOWED.
6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO
THE COMPLETION OF THE PROJECT:
A.TWO OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED
VALVES.
B.TWO OF EACH SERVICING WRENCH OR TOOL NEEDED FOR
COMPLETE ACCESS' ADJUSTMENT, AND REPAIR OF ALL ROTARY
SPRINKLERS.
C.“AS BUILT” IRRIGATION DRAWINGS
D.WATER BUDGET CHART
E.SMART IRRIGATION CONTROLLER DATA INPUT CHART SELECTED
NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARC WHICH
PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM
OVER-SPRAY FOR THE CONDITION. CAREFULLY ADJUST THE
RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY
SPRINKLER TO PROVIDE THE BEST PERFORMANCES.
THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE
INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE
REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT
EACH HARD-SCAPE CROSSING COORDINATE INSTALLATION OF
SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH
PASSES BENEATH EXISTING HARD-SCAPE WHERE SLEEVING
WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY
THE IRRIGATION CONTRACTOR.
O SEPARATE SLEEVING USED FOR IRRIGATION LINES AND
WIRING BUNDLES
O FOR ALL SLEEVING LOCATED UNDER CONCRETE, THE
PAVEMENT OR OTHER HARD
SURFACING SHALL BE NOTCHED ON BOTH SIDES TO MARK
THE SLEEVE LOCATION, AND TRACER WIRES SHALL BE
INSTALLED ON THE UPPER SIDE AND BOTH ENDS OF THE
SLEEVING.
O THE DIAMETER OF SLEEVE SHALL BE A MINIMUM OF TWICE
THAT OF THE PIPE AND WIRING BUNDLE BUT NO SMALLER
THAN A TWO (2) INCH DIAMETER PIPE. THE ENDS OF THE
SLEEVES SHALL EXTEND PAST THE EDGE OF THE CURB,
GUTTER, SIDEWALK, OR OTHER HARDSCAPE A MINIMUM OF
EIGHTEEN (18) INCHES.
O THE SLEEVE MATERIAL BENEATH SIDEWALKS, DRIVES AND
STREETS SHALL BE PVC CLASS 200 PIPE WITH SOLVENT
WELDED JOINTS
O CONTAINS NO JOINTS WHEN LENGTH IS LESS THAN TWENTY
(20) FEET.
7.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL
SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE
AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. THE
IRRIGATION CONTROLLER MUST BE WALL MOUNTED IN THE PARTS
STAGING AREA ADJACENT TO ELECTRICAL OUTLET LOCATED IN
THE JANITORS ROOM WITH BACKFLOW PREVENTER
8.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING. IF A
SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE
IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME
NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE
SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED
IN THE LEGEND.
9.INSTALL TWO #14 AWG CONTROL WIRES FROM CONTROLLER
LOCATION TO EACH DEAD END OF MAINLINE FOR USE AS SPARES
INCASE OF CONTROL WIRE FAILURE. COIL 3 FEET OF WIRE IN
VALVE BOX. END OF WIRES SHALL BE CAPPED WITH WATERPROOF
WIRE CONNECTORS
10.AUTOMATIC IRRIGATION SYSTEM SHALL BE EQUIPPED WITH AN
AUTOMATIC RAIN DETECTION DEVICE.
11.THE WATER AND SEWER DEPARTMENT RESERVES THE RIGHT TO
ENHANCE THE REQUIREMENTS OF THE BACKFLOW PREVENTER
INSTALLATION BASED ON CITY REQUIREMENTS.
12.NATIVE GRASS AREA WILL BE WATERED UNTIL ESTABLISHED FOR
UP TO THREE YEARS. TOUCH UP WATERING WILL BE DONE AS
NEEDED AFTER ESTABLISHMENT
13.POST AT EACH SMART IRRIGATION CONTROLLER A DATA INPUT
CHART INCLUDING THE PRECIPITATION RATE FROM THE AUDIT,
WATER BUDGET, AND ZONE DESCRIPTIONS.
14.WITHIN THIRTY (30) DAYS OF THE INSTALLATION OF NEW
LANDSCAPING, THE IRRIGATION SYSTEM CONTROLLER(S) SHALL
BE RESET TO THE NORMAL SEASONAL WATERING SCHEDULE.
EMITTER SCHEDULE
15.IN CLAY OR LOAM SOILS, CONSIDER TWO 0.5 GPH EMITTERS AT THE
BASE OF A PERENNIAL FLOWER TO ENSURE WATERING IF ONE
FAILS. A 1 TO 5 FOOT SHRUB AND SMALL TREE LESS THAN 15 FEET
AT MATURITY WILL INITIALLY REQUIRE TWO, 1 GPH EMITTERS 12
INCHES FROM THE BASE OF THE PLANT. CHANGE TO 2 AND THEN 4
GPH HIGHER FLOW EMITTERS IF PLANTING A LARGER SIZED TREE
AND AS THE SMALL TREE GROWS. A 5 FOOT OR LARGER SHRUB
MAY REQUIRE THREE 1GPH EMITTERS.
16.A MEDIUM TREE 15 TO 25 FEET MAY ULTIMATELY REQUIRE FOUR
EMITTERS TWO FEET FROM THE TRUNK. IF PLANTING A “WHIP”, IT’S
POSSIBLE TO START WITH TWO 0.5 GPH EMITTERS AND CHANGE TO
HIGHER FLOW AND MORE EMITTERS AS THE TREE GROWS. BEGIN
WITH THREE, 2 GPH EMITTERS ON A 1 INCH CALIPER TREE
PLANTING AND THREE, 4 GPH EMITTERS ON A 2 INCH CALIPER TREE
AT PLANTING.
17.TREES LARGER THAN 25 FEET AT MATURITY MAY BE IMPRACTICAL
TO IRRIGATE WITH DRIP BECAUSE OF THE EXTENSIVE NATURE OF
TREE ROOT SYSTEMS AND MASS OF THE TREES. INCREASE THE
NUMBER OF EMITTERS AND CHANGE THEM TO 2 OR 4 GPH OR
LARGER FLOWS AS TREES AND SHRUBS GROW.
EQUIPMENT
18.NON-POTABLE SYSTEMS MUST USE THE COLOR PURPLE TO
IDENTIFY COMPONENTS SUCH AS VALVES, VALVE BOXES,
SPRINKLER HEAD TOPS, ECT.
19.A MASTER SHUT-OFF VALVE SHALL BE INSTALLED DOWNSTREAM
OF THE BACKFLOW DEVICE.
20.FLOW SENSORS INTEGRATED WITH SMART IRRIGATION
CONTROLLER ARE REQUIRED FOR SINGLE OR COMBINED POINT OF
CONNECTION FOR FLOWS OF 15 GALLONS PER MINUTE OR
GREATER AND 1 INCH OR GREATER WATER TAPS.
21.ALL VALVES SHALL HAVE A MANUAL BALL VALVE INSTALLED
PRIOR TO THE LATERAL VALVE
.
22.ENSURE SLEEVING MEETS ALL REQUIREMENTS UNDER 6.11.B.6
INCLUDING BUT NOT LIMITED TO SLEEVING SIZE BEING TWICE
THAT OF THE PIPE, NOTCHING OF HARD SURFACE FOR SLEEVES
RUNNING UNDER HARDSCAPE.
13.5" (34.3 CM) OPEN DOOR WIDTH
5" WIDTH
(12.7 CM)
1
I CORE - WALL MOUNT
NOT TO SCALED
2
NOTE
MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL,
CONTROLLER SHALL BE HARD-WIRED TO GROUNDED
110 VAC POWER SOURCE
3
4
LEGEND:
FRONT ELEVATION
RIGHT ELEVATION
IRRIGATION CONTROLLER (I CORE) PER PLAN
IRRIGATION CONTROL WIRE IN CONDUIT
SIZE AND TYPE PER LOCAL CODES
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE, J-BOX INSIDE CONTROLLER
ADJACENT SURFACE TO MOUNT CONTROLLER PER PLAN
C.ICORE.01
1
2
3
4
4
PEB VALVE + PRS-DIAL + TBOS-II
1
5
4
2
3
Rain Bird PRS-Dial Pressure regulator
9V DC latching solenoid
2 x 1.5 mm² cable
Rain Bird waterproof wire connector
Manual valve
2
1
3
4
5
RAINBIRD REMOTE CONTROL VALVE
100-DV seriesC
IRRIGATION LEGEND
A1
1"
DRIP
15
REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER
LATERALS RAINBIRD PEB (SIZE PER PLAN)
POP-UP SPRAY SPRINKLER: RAIN BIRD 1802 WITH 1800 VPC
WITH RAIN BIRD ROTARY NOZZLE
INDICATES CONTROLLER STATION
INDICATES LATERAL DISCHARGE (GPM)
INDICATES VALVE SIZE (INCHES)
INDICATES LANDSCAPE APPLICATION
LATERAL PIPE TO SPRINKLERS: CLASS 200 PVC
1 INCH UNLESS OTHERWISE INDICATED
LATERAL PIPE TO EMITTERS: UV RADIATION RESISTANT
POLYETHYLENE (3/4-INCH SIZE, ROUTING DIAGRAM)
LEGEND/ANNUAL WATER NEEDS
92% LOW WATER ZONE
80,466sf x 7gal.= 563,262 gallons annually
8% HIGH WATER ZONE
4,662 sf x 18gal. = 50,040 gallons annually
TOTAL 613,302 gallons annually
OVERALL SITE USE = 4.7gal/sf