Loading...
HomeMy WebLinkAbout1041 - FCLWD TRILBY WATER TANK FEEDER LINE PRE-APPLICATION - - SUBMITTAL DOCUMENTS - ROUND 1 - Utility Plans30 IN TRILBY MAIN PROFILE STA: -0+50 - STA: 11+00 5110 5115 5120 5125 5130 5135 5140 5145 5150 5155 5160 5165 5110 5115 5120 5125 5130 5135 5140 5145 5150 5155 5160 5165 -0+500+000+501+001+502+002+503+003+504+004+505+005+506+006+507+007+508+008+509+009+5010+0010+5011+00 ST A : 4 + 4 0 . 6 8 TO P = 5 1 3 4 . 1 ± EX I S T . 1 2 " W A T E R TAFT HILL PAVEMENT LIMITS TAFT HILL ROAD RIGHT-OF-WAY EXISTING GROUND @ PIPE CENTERLINE ST A : 1 + 0 5 . 7 3 TO P = 5 1 3 0 . 4 ± EX I S T . 1 8 " W A T E R ST A : 2 + 3 8 . 9 6 TO P = 5 1 3 0 . 8 ± EX I S T . F I B E R O P T I C ST A : 2 + 5 2 . 6 7 TO P = 5 1 3 1 . 0 ± EX I S T . U G E L E C T R I C SCALE: 1" = 5' VERTICAL 1" = 50' HORIZONTAL MA T C H L I N E SE E S H E E T C1 0 ) ST A = 0 + 9 0 . 7 1 TO P = 5 1 2 3 . 9 BE G I N 4 8 " C A S I N G P I P E ST A = 1 + 7 3 . 7 7 TO P = 5 1 2 6 . 2 EN D 4 8 " C A S I N G P I P E ST A = 0 + 0 0 . 0 0 TO P = 5 1 2 0 . 7 CO N N E C T T O E X I S T . 3 6 " W A T E R 36 " T E E IN S T A L L 3 0 " B U T T E R F L Y V A L V E ST A = 4 + 1 4 . 3 3 TO P = 5 1 3 1 . 3 30 " 4 5 ° B E N D ST A = 4 + 5 6 . 8 8 TO P = 5 1 3 1 . 7 30 " 4 5 ° B E N D 1224.24 L F 3 0 " C 9 0 0 P V C 18" CLR. 40.80 LF 30" C900 PVC 83.05 LF 4 8 " C A S I N G 409.45 L F 3 0 " C 9 0 0 P V C 5' MIN. DEPTH ST A : 4 + 2 5 . 1 0 TO P = 5 1 3 5 . 5 ± EX I S T . G A S ENTRY DRIVE ENTRY DRIVE JOINT RESTRAINT LMIN.=83' (20' EACH SIDE OF BENDS) ST A : 0 + 9 0 . 3 7 TO P = 5 1 3 0 . 3 ± EX I S T . F I B E R O P T I C STA: 0+00.00 N: 97344.28 E: 184145.70 BEGIN ALIGNMENT 0+00 1+00 2+003+004+00 5+006+007+008+009+0010+0011+0012+00 MA T C H L I N E (S E E S H E E T C 3 . 0 1 ) PROPOSED CONNECTION TO EXISTING 36" STEEL WATERLINE 36" X 30" TEE WITH 30" BUTTERFLY VALVE (W) (SEE DETAIL SHEET C16) W. TRILBY ROAD TA F T H I L L R O A D EXISTING 30' WATER EASEMENT EXISTING PROPERTY BOUNDARY STA: 0+90.71 BEGIN 48" CASING PIPE N: 97344.28 E: 184054.99 STA: 1+73.77 END 48" CASING PIPE N: 97344.28 E: 183971.94 PROPOSED 20' X 16' RECEIVING PIT 83.05 LF 48" CASING EXISTING 100' R.O.W. STA: 4+14.33 30" 45° BEND N: 97344.28 E: 183731.37 40.80 LF 30" C900 PVC STA: 4+56.88 30" 45° BEND N: 97314.20 E: 183701.28 PROPOSED 30' FCLWD PERMANENT EASEMENT 1224.24 LF 30" C900 PVC 1224.24 LF 30" C900 PVC EXISTING 30' WATER EASEMENT UTILITY CROSSING 18" WATER UTILITY CROSSING UG ELECTRIC UTILITY CROSSING GAS UTILITY CROSSING 12" PVC WATER UTILITY CROSSING FIBER OPTIC PROPERTY OWNER: LARIMER COUNTY PROPERTY OWNER: CITY OF FORT COLLINS PROPERTY OWNER: CITY OF FORT COLLINS PROPERTY OWNER: EICHHOLZ PROPERTY OWNER: BOARD OF COUNTY COMM. PROPERTY OWNER: LARIMER COUNTY PROPOSED 54' TEMPORARY CONSTRUCTION EASEMENT PROPOSED 23' TEMPORARY CONSTRUCTION EASEMENT PROPOSED 81' X 92' (APPROX.) PERMANENT EASEMENT PROPOSED 44' X 16' BORE PIT PROPOSED 81' X 20' PERMANENT EASEMENT 23.5' TEMP. CONST. ESMT. EXISTING LARIMER COUNTY BEHAVIORAL HEALTH SIGN EXISTING IRRIGATION VALVE BOX (TYP.) EXIST. FIBER OPTIC UTILITY CROSSING FIBER OPTICEXISTING PRV VAULT (TO BE REMOVED) (BY OTHERS) FC L W D 6 . 0 M G T R I L B Y T A N K PREPARED FOR: SHEET NUMBER SHEETSOF FCLWD SUBMITTAL DATE: 06/09/2024 SCALE: VERTICAL:HORIZONTAL: UT CO Y IL I T NSULTING NO . BY DA T E RE V I S I O N S PRE L I M I N A R Y PLA N S NOT F O R C O N S T R U C T I O N 18 NOTES LEGEND CASING PIPE WATER FITTINGS 30" WATER MAIN THRUST BLOCK GATE VALVE EXISTING PROPERTY BOUNDARY PROPOSED PROPERTY LINE RIGHT OF WAY 24" WATER MAIN KEYMAP 1.THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, PAVEMENT, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 2.ALL WATERLINE CONSTRUCTION SHALL BE PER FORT COLLINS LOVELAND WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 3.MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5'. MAXIMUM COVER SHALL BE 6' UNLESS OTHERWISE NOTED ON THESE DRAWINGS. 4.24" & 30" PVC WATER LINES SHALL BE C900 PRESSURE CLASS 125 PVC PIPE. ALL DIP WATER LINES SHALL BE THICKNESS CLASS 53. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. SHOULD THE WATER LINE CROSS UNDER EITHER STORM DRAIN OR SANITARY SEWER, THE STORM OR SANITARY SHALL BE CONCRETE ENCASED FOR 10' ON EITHER SIDE OF THE CROSSING. 6.BENDS AND FITTINGS ON ALL NEW WATER MAIN (EXCEPT WHERE CONNECTING TO EXISTING MAINS) SHALL USE MECHANICALLY RESTRAINED JOINTS PER FORT COLLINS-LOVELAND WATER DISTRICT STANDARDS AND SPECIFIED LENGTHS. ALL FIRE HYDRANT LEADS AND FIRE SERVICES TO BUILDINGS SHALL BE INSTALLED WITH JOINT RESTRAINTS PER THE SAME REQUIREMENTS. WET TAP LOCATIONS SHALL BE INSTALLED WITH THRUST BLOCKS. 7.WHERE RESTRAINED JOINTS FOR HORIZONTAL AND VERTICAL FITTINGS OVERLAP RESTRAINTS SHALL BE EXTENDED USING THE LONGEST LENGTH. 8.BACKFLOW PREVENTION FOR WATER SERVICES SHALL BE PROVIDED WITHIN EACH BUILDING AND NO CONNECTIONS TO THE WATER SERVICES (INCLUDING IRRIGATION TAPS) SHALL BE MADE PRIOR TO THE BACKFLOW PREVENTION DEVICE. 9.ALL BURIED PVC PIPING HAS BEEN DESIGNED TO A WORKING PRESSURE OF 110 psi. THIS IS BASED ON FULL WATER TANK CONDITIONS AT THE TRILBY TANKS AND INCLUDES AN ADDITIONAL 50 psi SAFETY FACTOR ALLOWANCE. BURIED PVC PIPING AS NOT BEEN DESIGNED TO A 'DEAD HEAD' TAFT HILL PUMP STATION PUMPING CONDITION WITH SUCTION PRESSURES GENERATED BY FOOTHILLS TANK (APPROX. 185 psi). 10.ALL BURIED PIPING TO BE INSTALLED IN TYPE 5 TRENCH WITH FULLY BEDDED STRUCTURAL BACKFILL TO PIPE CROWN (DIP AND PVC) 11.LIMIT PIPE JOINT DEFLECTION TO 80% (MAX.) OF MANUFACTURERS MAXIMUM ALLOWABLE. BUTTERFLY VALVE 12" WATER MAIN EXISTING EASEMENT PERMANENT EASEMENT TEMPORARY CONST. EASEMENT 0 50'100' SCALE: 1" = 50' 25' N 30 I N C H T R I L B Y M A I N P L A N & P R O F I L E ST A 0 + 0 0 T O S T A 1 1 + 0 0 C9 9 1" = 5'1" = 50'