HomeMy WebLinkAboutSONDERS VILLAGE - PDP230012 - SUBMITTAL DOCUMENTS - ROUND 2 - Drainage Related Document
Preliminary Drainage and Erosion Control Report
for
Sonders East
Fort Collins, Colorado
Aug 7, 2024
Aug 7, 2024
Mr. Wes Lamarque
City of Fort Collins
Water Utilities--Storm water
700 Wood Street
Fort Collins, Colorado 80521
RE: Preliminary Drainage and Erosion Control Report Sonders East
Dear Wes:
We are pleased to submit to you, for your review and approval, this Preliminary Drainage and
Erosion Control Report for Sonders East. All computations within this report have been completed
in compliance with the City of Fort Collins Storm Drainage Design Criteria.
We appreciate your time and consideration in reviewing this submittal. Please call if you have any
questions.
Respectfully,
Aspen Engineering
John Gooch, P.E.
Principal
TABLE OF CONTENTS
DESCRIPTION PAGE
I. GENERAL LOCATION AND DESCRIPTION 5
A. LOCATION 5
B. DESCRIPTION OF PROPERTY 5
II. DRAINAGE BASINS 6
A. MAJOR BASIN DESCRIPTION 6
B. EXISTING SUB-BASIN DESCRIPTION 6
C. PROPOSED SUB-BASIN DESCRIPTION 6
III. DRAINAGE DESIGN CRITERIA 8
A. REGULATIONS 8
B. DEVELOPMENT CRITERIA REFERENCE AND CONSTRAINTS 9
C. HYDROLOGIC CRITERIA 10
D. HYDRAULIC CRITERIA 10
E. VARIANCES 10
IV. DRAINAGE FACILITY DESIGN 11
A. GENERAL CONCEPT 11
B. SPECIFIC DETAILS 12
C. DETENTION POND 20
D. PC SWMM/EPA SWMM MODEL 21
D. STREET CAPACITIES 22
V. STORM WATER QUALITY 22
A. GENERAL CONCEPT & SPECIFIC DETAILS 22
VI. EROSION CONTROL 23
A. GENERAL CONCEPT 23
VII. CONCLUSIONS 23
A. COMPLIANCE WITH STANDARDS & STORMWATER 23
OPERATIONS/ MAINTENANCE PROCEDURE
B. DRAINAGE CONCEPT 24
C. STORM WATER QUALITY 24
D. EROSION CONTROL CONCEPT 25
E. EROSION CONTROL ESCROW ESTIMATE 25
REFERENCES 25
APPENDIX
PAGE
VICINITY MAP, SOILS MAP, FEMA FIRMETTE A
RATIONAL METHOD HYDROLOGY, HISTORIC DRAINAGE
CALCULATIONS, STREET CAPACITIES , INADVERTENT STORAGE B
SWMM EXHIBIT AND PC SWMM/ EPA SWMM MODEL C
WQCV DETENTION POND DESIGN, RATING CURVES, AND LID SIZING D
PRELIMINARY No. 8 DITCH CALCULATIONS E
HISTORIC DRAINAGE BASIN MAP, PROPOSED DRAINAGE BASIN MAP,
EROSION CONTROL PLANS & EROSION CONTROL NOTES & DETAILS PLANS F
5
PRELIMINARY DRAINAGE
AND EROSION CONTROL REPORT
FOR SONDERS EAST
FORT COLLINS, COLORADO
I. GENERAL LOCATION AND DESCRIPTION
A. Location
The Sonders East project is located east of and adjacent to Turnberry Road (County
Road 11) and northeast of the intersection of Richards Lake Road and Turnberry
Road. The property is bounded to the west by Turnberry Road, to the north by an
existing irrigation ditch, to the east by W.P. Elder Reservoir Outlet Canal (No. 8
Ditch), and to the south by Richards Lake Road and the Lind Filing One property.
The project site can also be described as situated in the northwest quarter, and
southwest quarter of Section 29, Township 8 North, Range 68 West, of the 6th P.M.,
City of Fort Collins, County of Larimer, State of Colorado. The site (property
boundary) comprises approximately 129.54 acres (see vicinity map in Appendix A).
B. Description of Property
The project site currently contains an existing 129.54-acre vacant field comprised of
gravel access roads, and fields of native grasses and weeds. The site also includes
half of the existing Turnberry Road, as well as containing remnants of irrigation and
drainage structures on the east side of Turnberry Road. The south portion of the site
contains stockpiles of soil spoil piles and rock piles from the previous Lind Filing
One development. Spoil piles will be removed as part of the site demolition. The W.
P. Elder Reservoir Outlet Canal (No. 8 Ditch) conveys ditch flow from northwest to
southeast through the parcel and will be realigned and improved as part of this
project, subject to an agreement between Larimer Weld and the Owners/Developers.
The existing site has topography which generally slopes from the northwest to the
south-southeast, for the northern half of the site, at slopes varying from 1.5% to
2.0%. The south portion of the site slopes southwest at approximately 2.5% to 3.5%.
The proposed development consists of single-family homes, multi-family buildings,
park and amenity spaces, public and private streets, water, sanitary sewer, storm
sewer, and private infrastructure improvements, as well as intermittent green spaces
and outdoor spaces.
6
II. DRAINAGE BASINS
A. Major Basin Description
The Sonders East project is located within the City of Fort Collins Cooper Slough
Drainage Basin. The Cooper Slough Drainage Basin generally flows from north to
south and ultimately outlets into Larimer and Weld County Canal.
B. Existing Sub-Basin Description
The existing site consists primarily of dirt with intermittent grasses and weeds.
Existing onsite drainage from the northern portion of the site (Basin EX1) is
conveyed from the northwest to the east-southeast ultimately collecting along the
west edge of the No. 8 Ditch Rider Road, with flows then overtopping the shallow
inundation area and flowing east and into the No. 8 Ditch. Existing onsite drainage
from the southern half of the site (Basin EX2) flows predominantly from the
northwest to the east-southeast, with the far southeastern area of the site flowing
west-southwest, in which the entire southern area enters the existing detention pond
100, constructed with the Lind Filing One project. Please refer to Lind 1 drainage
basin map, as well as the existing drainage basin map for Sonders East, both
contained in Appendix F. The existing subject site is contained within two existing
sub-basins (EX1 and EX2). Existing basin EX1 contains approximately 64.45 acres
and was modeled with the basin having an existing ‘c’ value of 0.25. The calculated
existing 2-year runoff from basin EX1 is 17.03 cfs. Existing basin EX2 contains
approximately 65.09 acres and was modeled with the basin having an existing ‘c’
value of 0.25. The calculated existing 2-year runoff from basin EX2 is 18.30 cfs
Please refer to the rational calculations in Appendix B.
C. Proposed Sub-Basin Description
The proposed development consists of a future multifamily apartment building
complex, single family lot development, affordable housing development area, and
commercial/retail development area, along with associated street, water, sanitary
sewer, storm sewer, and private infrastructure improvements, as well as intermittent
green spaces and outdoor spaces.
The majority of site runoff generated from the proposed site will be conveyed to two
offsite Rain Gardens BMPs, which discharge into two adjacent offsite detention
ponds, located just east of the proposed project. The detention ponds ultimately
discharge into the W.P. Elder Reservoir Outlet Canal (No. 8 Ditch), as historically
occurs. The minority portion of the site discharges to an existing detention pond,
located to the southwest of the proposed development. This detention pond was
designed as a water quality/detention pond with the Lind Filing One development.
The Lind Filing One pond (Existing Pond 100) was oversized to accommodate future
flows into the pond. The original design assumed approximately 64.40 acres from
Sonders East would drain to the pond. The current design provides for the reduced
7
area of approximately 51.08 acres from Sonders East draining to the pond. The pond
currently has over 15 ac-ft of excess detention/water quality volume, after accepting
offsite flows from Sonders East and Lind Filing One.
The proposed public roads will be paved with asphalt, while the private drives and
adjacent parking areas will be constructed of concrete or asphalt. Interior sidewalks
will be constructed of concrete to serve pedestrians and provide access throughout
the site. Runoff from the proposed site will be conveyed in underground storm
drainage piping systems or on the surface, with flows ultimately conveyed to the
three ponds mentioned above. The two proposed detention ponds will be equipped
with Rain Gardens and forebays, to meet LID requirements for the site.
Runoff from the site will be conveyed to the Rain Gardens. The Rain Gardens will
provide approximately one (1) foot of ponding depth with base composed of
bioretention sand media and gravel over a 4” perforated underdrain system installed
at the bottom of the Rain Garden, thus meeting City LID criteria. Runoff captured in
the Rain Garden will be filtered through the media and gravel, routed in the
underdrain system, and will discharge into the proposed outlet structures, located at
the downstream ends of the two proposed detention ponds. Overflow spillways will
be constructed in each Rain Garden to allow runoff exceeding the LID volume to
overtop and enter the detention ponds. Should the volume entering the rain gardens
be in excess of what is allowed by the City, diversion structures will be provided to
send excess runoff directly to the detention ponds, thus bypassing the rain gardens.
This will be addressed as design progresses and will be included in the final design.
Table 1: DETENTION POND SUMMARY
Pond
100-yr
WSEL
(ft)
Volume
Required
(ac-ft)
Volume
Provided
(ac-ft)
Flow in
(cfs)
Flow out
(cfs)
100 5018.19 10.38 25.44 311.41 2.26
200 5041.89 10.88 11.24 281.06 20.16
300 5049.78 2.34 2.66 75.77 9.15
Total --- 23.60 39.34 668.24 31.57
The water quality is provided through two offsite Rain Gardens and the existing
water quality/detention pond designed and constructed with Lind Filing One. The
Rain Gardens will discharge into the two proposed detention ponds. The provided
water quality/LID volumes are tabulated below:
Table 2: LID RAIN GARDEN VOLUMES
LID Volume
Provided (ac-ft)
Volume
Required (ac-ft)
Rain Garden 200 1.09 0.87
Rain Garden 300 0.30 0.21
WQ Pond 100 0 0
8
Ponds 200 and 300 provide sufficient LID (rain gardens) treatment for the entire site.
Table 2 shows the required and provided water quality/detention volumes for the site.
Pond 100 is noted but not necessary to provide the minimum required LID treatment
for the site. The minimum single family impervious area required to have LID
treatment is 751,825 square feet (sf). The minimum required multifamily impervious
area required to have LID treatment is 871,315 sf. The Rain gardens provided in
Ponds 200 and 300 treat 906,442 sf of single-family impervious area and 748,181 sf
of multi-family impervious area. The combined hard area required to be treated for
the single-family and multi-family areas is 1,623,140 sf. The LID rain gardens in
Ponds 200 and 300 treat a total of 1,654,623 sf, which exceeds the total amount
required. Because Pond 100 is existing and the intent is to minimize disruption to the
pond during construction, LID treatment for the Sonders east development is
provided for in Ponds 200 and 300. Please refer to LID table in Appendix D.
Should the Rain Gardens fill up during major storm events, the Rain Gardens will
overtop the spillways and drain to the proposed detention ponds.
The proposed detention ponds will be graded with relatively flat bottoms (0.5% to
1.0%) to allow for infiltration and pollutants to settle out of the runoff, prior to flows
exiting the ponds via the proposed outlet structures and into W.P. Elder Reservoir
Outlet Canal (No. 8 Ditch). Please refer to the grading plans for details.
The proposed detention ponds will discharge a combined flow rate of 31.57cfs to the
No. 8 Ditch, which includes the 3 cfs from the Lind Filing 1 pond.
Per the Geotechnical report by CTL Thompson, the site contains slightly expansive
clay materials. The contractor shall follow the mitigation methods presented in the
Geotechnical Report and consult with the Geotechnical Engineer as required for
recommendations on site specific soil types in providing construction of the
detention pond and LID treatment areas.
III. DRAINAGE DESIGN CRITERIA
A. Regulations
The Sonders East site, located in the Cooper Slough Drainage Basin, will be
designed to detain the 100-year stormwater runoff under the developed condition.
The release rate from the ponds is regulated by the Windsor Reservoir Canal
Company. The drainage design calculations for the subject site are required to be in
compliance with the current City of Fort Collins Stormwater and Erosion Control
Standards and requirements, and applicable criteria and design methods provided in
the Mile High Flood District (MHFD). The Rational Method and EPA SWMM have
been used to calculate stormwater runoff and proposed detention pond volumes.
Requirements of the Geotechnical Report by CTL Thompson must also be
implemented in the grading and drainage design for the site. The drainage design for
9
the subject site will be designed in accordance with these standards and design
criteria and provides for the site drainage being conveyed to downstream Rain
Gardens and detention ponds, as required and applicable, during the next phase in the
project design.
The proposed detention ponds will discharge a combined flow rate of 31.57 cfs to the
No. 8 ditch. The client is currently working with the No. 8 Ditch board to reach an
agreement to accept the flows. This is in addition to the historic 3cfs from the Lind
Filing 1 pond released to the No. 8 ditch.
B. Development Criteria Reference and Constraints
Drainage criteria and constraints required by the City of Fort Collins and Windsor
Reservoir Canal Company, will be achieved, and provided by the Sonders East
project. The City of Fort Collins requires that the release rate from the site be no
more than the 2-year historic rate. The rational method calculations in Appendix B
show a 2-year existing/historic flow rate from Basins EX-1 and EX-2 of 35.33 cfs.
The proposed design provides for a combined release rate of 31.57 cfs from existing
Pond 100 (constructed with Lind Filing One) and proposed Ponds 200 and 300.
There are on-going discussions between the developer and the Windsor Reservoir
Canal Company regarding requirements for allowable discharge from the
development to the No. 8 ditch and the associated configuration and construction
standards. State law requires that the development can cause no change to the
discharge rate to the ditch, the quality of storm water, the discharge location and the
quantity of stormwater to the ditch without approval from the ditch company. We
have addressed discharge rate by complying with the City of Fort Collins regulations
of only discharging the storm water at less than the 2-year historic rate. The quality
of the storm water is mitigated by installing LID rain gardens prior to discharge to
the No. 8 ditch. The discharge location to the No. 8 ditch will no longer be
distributed along the length of the ditch but will be discharged via a pipe at agreed
locations. The quantity of storm water to the ditch will increase due to the increase
in hard area of the development. There is no means of mitigating or reducing this
quantity, so will need to be agreed to with the Windsor Reservoir Canal Company.
The design of the relocated ditch will be agreed to with the Windsor Reservoir Canal
Company and their engineer.
C. Hydrologic Criteria
The Rational Method for determining surface runoff was used for the project site.
The 2-year and 100-year storm event intensities were used in calculating runoff
values. The City of Fort Collins intensity duration frequency curves were used to
obtain rainfall data for each of the specified storm events.
10
Water quality pond sizing was calculated using the latest City of Fort Collins Criteria
as well as Mile High Flood District sizing methods and spreadsheets. Detention
pond sizing was calculated using EPA SWMM.
Rain Garden sizing was calculated using the Design Procedure Form for Rain Garden
Design spreadsheet developed by MHFD.
Street capacity calculations were determined using the MHFD street capacity
spreadsheet. To be conservative at this time, a 0.5% minimum slope was assumed for
the street. The flows were obtained from the street conveyance links in the EPA
SWMM model. At all locations throughout the development, the flow does not
exceed the street capacity for both the 2-yr and 100-yr storm events.
These calculations and criteria are provided in Appendices B and C of this report.
D. Hydraulic Criteria
All hydraulic calculations within this report have been prepared in accordance with
the City of Fort Collins Drainage Criteria and are also included in the Appendices.
Preliminary storm sewer pipe sizing was not performed at this time. The pipes in
EPA SWMM are a place holder to analyze the routing and were not used to size the
drainage system at this time.
Final storm sewer pipe/systems and inlet/curb cut sizing will be provided in final
design. Orifice/inlet control sizing will be calculated in final design. Final swale
sizing will be completed during final design. Final erosion control and riprap sizing
will be provided in final design using North American Green software and riprap
spreadsheet software.
E. Variances
No variances are being requested at this time.
IV. DRAINAGE FACILITY DESIGN
A. General Concept
Fifty-four proposed onsite drainage basins and thirteen offsite basins have been
created to analyze the drainage for the proposed development.
Basins 1-6, 50, and basins OS2-OS4, OS10, and OS11 drain ultimately to a proposed
offsite detention/water quality pond (Pond 300), located east of the northeast portion
11
of the site, via overland flow, curb and gutter, and proposed storm sewer systems.
The 100-year peak flow to be detained in detention Pond 300 will be approximately
76 cfs.
Basins 7-23, 32-33, OS5-OS8, and OS13 drain ultimately to a second proposed
offsite detention/water quality pond (Pond 200), located east of the site, via overland
flow, curb and gutter, and proposed storm sewer systems. The 100-year peak flow to
be detained in Pond 200 will be approximately 281 cfs.
Basins 24-31, 34-49, 51-52, and OS-9 drain ultimately to an existing detention/water
quality pond (Pond 100), located in the southwest corner of the site, via overland
flow, curb and gutter, and proposed storm sewer systems. The 100-year peak flow to
be detained in existing Pond 100 will be approximately 311 cfs (including flows
from Lind Filing One).
Basin OS12 is an offsite basin that will be sheet flow overland and into the W.P.
Elder Reservoir Outlet Canal (No. 8 Ditch) undetained.
The total 100-year peak flow to be detained in the two proposed detention ponds,
along with the existing Lind 1 pond, will be approximately 668 cfs.
Existing detention Pond 100 (southwest), Detention Pond 200 (east), and Detention
Pond 300 (northeast) provide approximately 10.38 acre-feet, 10.88 acre-feet and 2.34
acre-feet of storage, respectively. Water quality is provided in the proposed Rain
Gardens, located upstream of Detention Ponds 200 and 300. A Water Quality
Control Volume is also provided within Pond 100 for runoff not directed to the Rain
Garden.
The proposed release rate for the site is 31.57 cfs. The release rates for Ponds 100,
200 and 300 will be 2.26 cfs, 20.16 cfs, and 8.89 cfs, respectively.
Please refer to the rational calculations in Appendix B and the Proposed and Existing
Drainage Basin Exhibits in Appendix F for additional information.
B. Specific Details
Drainage to Detention Pond 300:
The runoff from the following basins will be collected in a proposed storm sewer
system which will ultimately be conveyed to the Rain Garden upstream of Detention
Pond 300, located at the northeast corner of the site. The Rain Garden discharges
into the proposed Detention Pond 300.
12
Basin 1
Runoff in Basin 1 will drain via overland flow to a drainage swale that travels
along the east side of the site, within Basin OS-10, to the Rain Garden
upstream of Detention Pond 300.
Basin 2
Runoff in Basin 2 will drain via overland flow to the curb and gutter in
Sternwheeler Court. The flow from Sternwheeler Court will discharge on
Grassland Road where it will be collected in a proposed storm drainage
system.
Basin 3
Runoff in Basin 3 will drain via overland flow and curb and gutter to
Grassland Road where it is collected in a proposed storm drainage system.
Basin 4
Runoff in Basin 4 will drain via overland flow and curb and gutter to
Greenspace Road. Inlets on Greenspace Road collect the flow and convey it
in the proposed storm drainage system to the Rain Garden upstream of
Detention Pond 300.
Basin 5
Runoff in Basin 5 sheet flows to the east where it is collected in the proposed
drainage swale along the east side of the development. The swale discharges
to the Rain Garden upstream of Detention Pond 300.
Basin 6
Runoff in Basin 6 travels via overland flow and curb and gutter to Nature
Parkway. Nature Parkway drains to Greenspace Road where the runoff is
collected in the proposed storm drainage system.
Basin 50
Runoff from Basin 50 will travel via overland flow to the proposed drainage
swale that will travel along the east side of the development. The swale
discharges into Detention Pond 300.
Basin OS-1
Runoff from a small northern portion of Basin OS-1 will flow overland to the
east and into the No. 8 Ditch, as historically occurs. The majority and
remaining portion of Basin OS-1 will be conveyed via overland flow east and
into basin OS-10 and is conveyed southeast in a proposed drainage swale to
the area inlet at design point OS-10. However, because this basin is offsite to
the north, the basin area is not included in water quality or detention pond
sizing for this development.
13
Basin OS-2
Runoff from Basin OS-2 will drain via overland flow and curb and gutter and
curb cuts into Basins 1 and 2. See Basins 1 and 2 for continued flow path
information.
Basin OS-3
Runoff in Basin OS-3 will drain via overland flow and curb and gutter to a
curb cuts along Turnberry Road. The curb cuts direct the water overland to a
drainage swale along the west side of basin 2. The swale discharges to
Grassland Road where it is collected in a proposed storm drainage system.
Basin OS-4
Runoff in Basin OS-4 will drain via overland flow and curb and gutter to a
curb cuts along Turnberry Road. The curb cuts direct the water overland to a
drainage swale along the west side of Basin 3. The swale discharges to
Grassland Road where it is collected in a proposed storm drainage system.
Basin OS-10
Runoff from Basin OS-10 will flow southeast in a proposed drainage swale to
the area inlet at design point OS-10, with flow then directed to the LID Basin
within Pond 300.
Basin OS-11
Basin OS-11 contains Pond 300, with runoff from this area entering the LID
Basin and Pond 300.
Drainage to Detention Pond 200:
The runoff from the following basins will be collected in a proposed storm sewer
system which will ultimately be conveyed to the Rain Garden upstream of Detention
Pond 200, located at the northeast corner of the site. The Rain Garden discharges
into proposed Detention Pond 200.
Basin 7
Runoff in Basin 7 travels via overland flow and curb and gutter to
Sternwheeler drive. Sternwheeler drive drains to Field Point Way then to
Greenspace Road and ultimately to a drainage system that collects the flow
and discharges it to the Rain Garden upstream of Detention Pond 200.
Basin 8
Runoff in Basin 8 drains to Greenspace Road. The flow on Greenspace Road
is collected in travels south via curb and gutter to proposed Type R inlets that
connect the proposed storm drainage system.
14
Basin 9
Runoff in Basin 9 drains via overland flow and curb and gutter to
Meadowlark Road. Inlets are located in a low spot along Meadowlark Road
which collects the runoff and conveys it in the proposed drainage system to
the Rain Garden upstream of Detention Pond 200.
Basin 10
Runoff in Basin 10 drains via overland flow and curb and gutter to
Meadowlark Road. Inlets are located in a low spot along Meadowlark Road
which collects the runoff and conveys it in the proposed drainage system to
the Rain Garden upstream of Detention Pond 200.
Basin 11
Runoff in Basin 11 travels via overland flow and curb and gutter to Nature
Park Way. Runoff in Natures Park Way drains to the south, via curb and
gutter, and to a low spot which collects the runoffs in proposed inlets and into
a proposed storm drainage system.
Basin 12
Runoff in Basin 12 travels via overland flow and curb and gutter to Nature
Park Way. Runoff in Natures Park Way drains to the south, via curb and
gutter, and to a low spot which collects the runoffs in proposed inlets and into
a proposed storm drainage system.
Basin 13
Runoff in Basin 13 travels east via overland flow and curb and gutter to
Greenspace Road. Inlets are located in a low spot along Greenspace Road
which collects the runoff and conveys it in the proposed drainage system to
the Rain Garden upstream of Detention Pond 200.
Basin 14
Runoff in Basin 14 travels east via overland flow and curb and gutter to High
Meadow Road. Inlets are located in a low spot along High Meadow Road
which collects the runoff and conveys it in the proposed drainage system to
the Rain Garden upstream of Detention Pond 200.
Basin 15
Runoff in Basin 15 travels south via overland flow to an area inlet located
north of Parkland Road.
15
Basin 16
Runoff in Basin 16 travels north to Parkland Road via overland flow and curb
and gutter. The flow then travels east via curb and gutter to High Meadow
Road where it combines with the flow from Basin 14.
Basin 17
Runoff in Basin 17 overland flows to Pathway Road. The flow then travels
east via curb and gutter to High Meadow Road where it combines with the
flow from Basin 14.
Basin 18
Runoff in Basin 18 travels west via overland flow and curb and gutter to
High Meadow Road. Inlets are located in a low spot along High Meadow
Road which collects the runoff and conveys it in the proposed drainage
system to the Rain Garden upstream of Detention Pond 200.
Basin 18A
Runoff in Basin 18A travels via overland flow and curb and gutter to High
Meadow Road. Proposed inlets collect the water and convey it in the
proposed storm drainage system.
Basin 19
Interior runoff in Basin 19 sheet flows to local inlets and then to the main
storm drain of Detention Pond 200. Runoff from the exterior (eastern) of
Basin 19 is collected by swales to an inlet then to Pond 200. Final Drainage
patterns will be done at Final Design.
Basin 20
The runoff in Basin 20 travels to the east via overland flow and curb and
gutter to Sternwheeler Road. The flow in Sternwheeler Road drains to the
south via curb and gutter to Morning Star Drive where it is ultimately
collected in inlets and conveyed in the proposed storm drainage system.
Basin 21
Runoff in Basin 21 travels to the south and to Walking Stick Way via
overland flow. The runoff in Walking Stick Way flows to the east to High
Meadow Road where it is ultimately collected in inlets and conveyed in the
proposed storm drainage system.
Basin 22
Runoff in Basin 22 travels east through the basin via overland flow and curb
and gutter and ultimately to Morning Star Drive. Inlets located at a low spot
on Morning Side Drive collects the flow and conveys in the proposed storm
drainage system to Detention Pond 200.
16
Basin 22A
Runoff in Basin 22A travels to the east via overland flow to High Meadow
Road where it is ultimately collected in inlets and conveyed in the proposed
storm drainage system.
Basin 23
Runoff in Basin 23 travels to the north via overland flow and curb and gutter
to Morning Star Drive. The runoff in Morning Side Drive flows to the east
where it is collected in proposed Type R inlets. The inlets discharge into a
proposed storm drainage system and ultimately to Detention Pond 200.
Basin 32
Runoff in Basin 32 travels to High Meadow Road via overland flow and curb
and gutter. High Meadow Road drains to a low point where Type R inlets
collect the flow and discharges it overland and onto Basin 19 and then via a
swale to Pond 200.
Basin 33
Runoff in Basin 33 travels to High Meadow Road via overland flow and curb
and gutter. High Meadow Road drains to a low point where Type R inlets
collect the flow and discharges it overland and onto Basin 19 and then via a
swale to Pond 200.
Basin OS-5
Runoff in Basin OS-5 will drain via overland flow and curb and gutter to a
curb cut along Turnberry Road. The curb cuts direct the water overland to
Amble Lane. Amble Lane discharges to Sternwheeler Drive.
Basin OS-6
Runoff in Basin OS-6 will drain via overland flow and curb and gutter to a
curb cut along Turnberry Road. The curb cuts direct the water overland to
Pathway Lane. Pathway Lane discharges into Greenspace Road.
Basin OS-7
Runoff in Basin OS-7 will drain via overland flow and curb and gutter to a
curb cut along Turnberry Road. The curb cuts direct the storm drainage
overland to site curb and gutter then to Parkland Road
Basin OS-8
Runoff in Basin OS-8 will drain via overland flow and curb and gutter to a
curb cut along Turnberry Road. The curb cuts direct the water overland to a
parking lot on Basin 20. The parking lot drains to Sternwheeler Drive and
ultimately to the proposed storm drainage system.
17
Basin OS-13
Basin OS-13 contains Pond 200, with runoff from this area entering the LID
Basin and Pond 200.
Drainage to Detention Pond 100:
The runoff from the following basins will be collected in a proposed storm sewer
system which will be ultimately conveyed to an existing detention pond, located on
Lind 1 at the southeast corner of the Lind 1 site. Detention Pond 100 is also a water
quality pond and will treat the basins summarized below.
Basin 24
Runoff in Basin 24 will overland flow to the southeast comer of the basin and
to Fairwater Drive. Fairwater Drive flows to the south and to the proposed
drainage system.
Basin 25
Runoff in Basin 25 will overland flow to the west and to Fairwater Drive.
Fairwater Drive flows to the south and to the proposed drainage system.
Basin 26
Runoff in Basin 26 will sheet flow to Sternwheeler drive. Inlets located at a
low spot Sternwheeler Drive will collect the runoff and convey it via a
proposed drainage system to Detention Pond 100.
Basin 27
Runoff in Basin 27 flows via overland flow and curb and gutter to the west to
Sternwheeler Drive. Inlets located at the low spot in Sternwheeler collect the
flow and convey it in a proposed storm drainage system to Detention Pond
100.
Basin 28
Runoff from Basin 28 flows to the center of the basin where it is collected in
a proposed drainage channel and local drainage inlets. The storm drainage
then discharges to Type R inlets and storm drainage system, which
discharges to Pond 100.
Basin 29
Runoff in Basin 29 flows via overland flow and curb and gutter to the center
of the basin where it is collected in several area inlets. These inlets will
convey the proposed runoff to Detention Pond 100 via the storm drainage
system.
18
Basin 30
Runoff in Basin 30 travels southeast to an existing Type R inlet in
Brightwater Drive and via the existing drainage system to existing Detention
Pond 100.
Basin 31
Runoff in Basin 31travels to the west via overland flow and curb and gutter
to Trailway Road. The runoff on Trailway Road flows to the south then
southwest along Stardust Way to two proposed Type R Inlets.
Basin 34
Runoff in Basin 34 travels to the south via overland flow and curb and gutter
and ultimately onto Brightwater Drive.
Basin 35
Runoff in Basin 35 travel to the south and onto Brightwater Drive. Runoff
on Brightwater Drive flows to the southwest where it is collected through
Type R inlets and into the proposed storm drainage system.
Basin 36
Runoff in Basin 36 travel to the south and onto Brightwater Drive. Runoff
on Brightwater Drive flows to the southwest where it is collected through
Type R inlets and into the proposed storm drainage system.
Basin 37
Runoff in Basin 37 travels to the south via curb and gutter and overland flow
to Wellness Road. The runoff on Wellness Road flows to the south via curb
and gutter then to Type R Inlets and into the proposed drainage system.
Basin 38
Runoff in Basin 38 travels to the south via curb and gutter and overland flow
to Wellness Road. Then south along Wellness Road to Typer R Inlets and
into the proposed drainage system.
Basin 39
Runoff in Basin 39 sheet flows to a drainage channel that is located along the
east side of the development. The drainage swale ultimately discharges into
Detention Pond 100 after combining with runoff from Basin 49.
Basin 40
Runoff in Basin 40 flows to the south and onto Clipper Way via overland
flow and curb and gutter. The flow on Clipper Way travels to the east then to
Type R inlets in Wellness Road and into the proposed drainage system which
discharges to Pond 100.
19
Basin 41
Runoff in Basin 41 travels to the south via curb and gutter and overland flow
to Clipper Way. The runoff on Clipper Way flow to the west via curb and
gutter where it combines with the flow from Basins 40 and 38 in Wellness
Road. There are inlets located at a low spot on Wellness Road that collects
the flow and discharges it into Detention Pond 100 via the proposed storm
drainage system.
Basin 42
Runoff in Basin 42 sheet flows overland via a swale to the south and to
Detention Pond 100.
Basin 43
Runoff in Basin 43 travels to Wellness Road via overland flow and curb and
gutter. The runoff on Wellness Road travels to the south to inlets located at a
low spot near Greenspace Way.
Basin 44
Runoff in Basin 44 travels to the south viz overland flow and curb and gutter
to an area inlet located north of Greenspace Way. The inlet conveys the flow
to Detention Pond 100 via the proposed storm drainage system.
Basin 45
Runoff in Basin 45 travels to the south via overland flow and curb and gutter
to an area inlet located north of Greenspace Way. The inlet conveys the flow
to Detention Pond 100 via the proposed storm drainage system.
Basin 46
Runoff from Basin 46 flows vias overland flow and curb and gutter to High
Meadow Road. The runoff in High Meadow Road flows to the south and to
proposed inlets where it is collected and discharged into Detention Pond 100.
Basin 47
Runoff in Basin 47 travels to the southwest via overland flow and curb and
gutter to Fieldview Road. The storm drainage on Fieldview Road flows to
Clarion Lane where it is collected in proposed Type R inlets located at a low
spot on the road. The inlets discharge into Detention Pond 100 via the storm
drainage system.
Basin 48
The runoff in Basin 48 travels to the southwest via overland flow and curb
and gutter to Clarion Lane. The flow on Clarion Lane is collected in
proposed Type R inlets located at a low spot on the road. The inlets
discharge into Detention Pond 100 via the storm drainage system.
20
Basin 49
Runoff in Basin 49 sheet flows to the south and into a proposed drainage
swale traveling along the southern boundary of the site. The drainage
channel discharges into Detention Pond 100.
Basin 51
Runoff in Basin 51 flows overland to the west into the Bar Harbor Drive curb
and gutter then to the existing drainage system to Pond 100.
Basin 52
Runoff Basin 52 flows overland directly into Pond 100.
Basin OS-9
Runoff in Basin OS-9 will drain via overland flow and curb and gutter to a
curb cuts along Turnberry Road. The curb cuts direct the water overland to
Basin 26 and ultimately to Sternwheeler Drive.
Offsite Drainage
The runoff from the following basin drains offsite.
Basin OS-1
The northern portion of Basin OS-1 will flow east and into the No. 8 Ditch,
as historically occurs. The remaining portion of Basin OS-1 will be
conveyed through basin OS-10 and will be passed through detention pond
300. Basin OS-1 is not included in water quality or detention pond sizing
calculations for this development.
Basin OS-12
Runoff in Basin OS-12 sheet flows to the irrigation ditch running along the
eastern boundary of the basin.
C. Detention Pond
Detention Pond 300 has been sized to provide detention for 23.02 acres which
includes Basins 1-6, 50, OS2-OS4 and OS10-OS11. Detention Pond 300 will
provide 2.34 acre-feet of available volume at an elevation of 5049.78. The Rain
Garden adjacent to Pond 300 will provide 0.30 acre-feet of available volume at an
elevation of approximately 5050.
Detention Pond 200 has been sized to provide detention for 66.6 acres which
includes Basins 7-23, 32, 33 and basins OS5-OS8, and OS13. Detention Pond 200
will provide 10.88 acre-feet of available volume at an elevation of 5041.89. The
Rain Garden adjacent to Pond 200 will provide 1.09 acre-feet of available volume at
an elevation of approximately 5042.
21
Existing Detention Pond 100 was previously sized with the Lind Filing One
development to detain a portion of the flow from Sonders East, in which Pond 100
was designed to provide approximately 21.68 ac-ft of combined detention and water
quality volume for Lind Filings 1, 2, and 3, with 1.73 ac-ft of this volume being
water quality. The current as-built rating curve for Pond 100 demonstrates nearly
25.44 ac-ft of available volume.
Today, Sonders East is what would have been Lind Filings 2 and 3, and the proposed
plans entail keeping existing Pond 100 in its original state, but with some added
storm outfall pipes entering the pond from the Sonders East development. Water
quality sizing for the entire onsite basins within the development (126.27 acres @
50% imperviousness) was calculated to be 2.17 ac-ft. Assuming approximately 0.8
ac-ft of water quality being required for, and attributable to Lind Filing 1, today’s
required water quality capture volume is approximately 2.97 ac-ft. Considering LID
treatment from the rain gardens near Ponds 200 and 300 providing approximately
1.39 ac-ft of water quality treatment, Pond 100 is only required to provide the
remaining 1.58 ac-ft water quality for the site. The SWMM model for the project
demonstrates that 10.38 ac-ft of detention is required for Pond 100, which added to
the 1.58 ac-ft of required water quality, brings the total required volume in Pond 100
to 11.96 ac-ft.
However, because Pond 100 is already oversized (25.44 ac-ft available), detention
and water quality are far exceeded in Pond 100, and existing Pond 100 will provide
water quality and detention for 95.98 acres, which includes Basins 24-49, 51-52, OS9
and Lind 1. Detention Pond 100 will provide the 10.38 acre-feet of available volume
at an elevation of 5018.19.
The proposed detention ponds will allow for detention up to the 100-year storm event
for the development. The lowest outlet elevation of Detention Pond 300 (invert at
the front of the outlet structure) is approximately 5044.5. The calculated 100-year
water surface elevation of Detention Pond 300 is approximately 5049.78 with a
release rate of 9.15 cfs.
The lowest outlet elevation of Detention Pond 200 (invert at the front of the outlet
structure) is approximately 5036. The calculated 100-year water surface elevation of
Detention Pond 200 is approximately 5041.89 with a release rate of 20.16 cfs.
The lowest outlet elevation of the existing Detention Pond 100 (invert at the front of
the outlet structure) is approximately 5012.25. The calculated 100-year water
surface elevation of existing Detention Pond 100 is approximately 5018.19 with a
release rate of 2.26 cfs. Even after the addition of the area from the Sonders East
development that drains to the existing pond, the pond has excess volume that can be
used for further water quality treatment.
22
The combined release from Ponds 100 through 300 is 31.57 cfs, with this rate being
the total proposed discharge rate to the W.P. Elder Reservoir Outlet Canal.
An Emergency Spillway will be constructed along the south/east edges of Ponds 200,
and 300. The proposed spillway for Pond 100 will remain, as previously constructed
with the Lind Filing One development.
North American Green C350 Erosion Control Fabric will also be provided on the
spillways to mitigate erosion, in event the ponds overtop.
D. PC SWMM/EPA SWMM Model
To analyze the detention ponds in the Sonders East development, a PC SWMM
model was created for the site drainage. PC SWMM uses EPA SWMM to analyze
the proposed storm sewer system and size proposed detention ponds. Please refer to
the attached SWMM Exhibit in Appendix C for details. The model contains street
links and storm conduits to route the flows through the site and to the proposed
Detention Ponds.
E. Street Capacities
Street capacity calculations were determined using the MHFD street capacity
spreadsheet. To be conservative at this time, a 0.5% minimum slope was assumed for
the street. The flows were obtained from the street conveyance links in the EPA
SWMM model. At all locations throughout the development, the flow does not
exceed the street capacity for both the 2-yr and 100-yr storm events.
Street capacity calculations can be found in Appendix B.
V. STORM WATER QUALITY
A. General Concept & Specific Details
The water quality of stormwater runoff must be addressed on all final design utility
plans. The Four Step Process is used to design the Best Management Practices for
the site.
Step 1: Runoff Reduction
Step 2: Implement BMPs That Provide a WQCV with Slow Release
Step 3: Stabilize Streams
23
Step 4: Implement Site Specific and Other Source Control BMPs
Runoff Reduction
Common areas are provided between blocks of single-family homes to provide a
landscape buffers with gravel paths or paved sidewalks. Drainage is conveyed over
and through these buffers before entering ponds.
Therefore, Best Management Practices (BMP's) for the treatment of stormwater
runoff for the subject site will include grass/ sod-lined swales, riprap pads at culvert
discharge points, riprap or permanent erosion control fabric at curb cuts and swale
entrances into the ponds, grass scrubbing across the bottom of the detention ponds
during first flush conditions, and proposed Rain Gardens consisting of water quality
catch basins located at the entrances to the detention ponds, which have been
incorporated into the detention pond design. These proposed water quality features
will provide a mechanism for pollutants to settle out of the stormwater runoff before
flows are directed into the detention ponds.
The proposed water quality/ detention facilities have adequate capacity and will
provide all of the required water quality and detention up to the 100-year event for
the developed condition of the subject site prior to releasing flows to W.P. Elder
Reservoir Outlet Canal
VI. EROSION CONTROL
A. General Concept
The subject site soils are classified as Hydrologic Groups B and C, with an erosion K
factor ranging from 0.28 to 0.43. The Wind Erodibility Group is rated 4L, 5, and 6,
according to the USDA Soil Properties. The potential exists for erosion problems
during construction, but should be minimal after completion of proposed
development. Silt fence will be installed along the north, west, south, and east
portions of the site to prevent sediment from leaving the site. Vehicle tracking pads
will also be placed at entrances/exits to the site, with the exact location(s) provided
during final design.
24
Straw Wattles and gravel inlet filters will be placed at proposed and nearby, existing
inlet locations to mitigate the build-up of sediment in the existing and proposed inlets
and manhole structures. Straw wattle check dams will also be installed at 300'
intervals in the proposed swales throughout the site, as may be applicable. Concrete
forebays will be installed at several concentrated flow areas that enter the Rain
Garden/ LID basin, as well as special gravel inlet filters placed at pond outlet
structures.
Erosion Control Calculations and the Erosion Control Escrow Amount will be
provided during final design. Please refer to Appendix F for the Erosion Control
Plan and Erosion Control Notes and Detail Sheets.
VII. CONCLUSIONS
A. Compliance with Standards & Stormwater Operations/Maintenance Procedure
All computations within this report have been completed in compliance with the City
of Fort Collins Storm Drainage Design Criteria.
The City of Fort Collins Storm water Utility will not maintain the on-site storm
drainage facilities within the subject site. The owners of the subject site will
maintain their on-site storm drainage facilities on a regular basis. The following
shall be implemented for the private stormwater improvements’ operations/
maintenance procedures for the project on an annual or bi-annual basis:
1) Storm Sewer Inlets, pipes and flared-end-sections, curb cuts and concrete
sidewalk culverts/chases, structures, manholes, and the LID water quality
catch basins shall be cleaned through the removal of debris and sediment
from the associated items to allow for adequate drainage through the site to
the proposed detention facilities.
2) Pond sedimentation/ silting shall be removed to allow for adequate drainage
along the bottom of the ponds and to prevent ponding and silting in of the
pond bottoms. Grass scrubbing along the bottom of the ponds may be
required to remove sediment and promote grass growth.
3) Re-vegetation using Natural Seeding/ Sod shall be provided for disturbed
areas and other permanent erosion controls shall be provided for areas where
erosion has taken place and requires remediation back to the proposed
condition shown in the plans.
The Stormwater Operating/ Maintenance Procedures listed above are guidelines to
the minimum procedures that shall be implemented for the site, with these and
additional measures being utilized on an as-needed basis.
25
B. Drainage Concept
The proposed drainage concepts presented in this study and shown on the utility
plans adequately provide for the transmission of developed on -site runoff to the
existing and proposed detention ponds (Existing Pond 100, and proposed Ponds 200
and 300), located southwest and east of the subject site. The proposed storm sewer
system will provide for the 100-year developed flows to reach the existing and
proposed water quality and detention ponds, prior to the combined 31.57 cfs flow
being released downstream to the No. 8 Ditch.
If groundwater is encountered at the time of construction, a Colorado Department of
Health Construction Dewatering Permit will be required.
C. Storm Water Quality
The preliminary design has addressed the water quality aspect of stormwater runoff.
The proposed grass-lined detention ponds and Rain Gardens will provide an
opportunity for stormwater pollutants to filter out of the stormwater runoff before
flows are directed downstream to W.P. Elder Reservoir Outlet Canal (No. 8 Ditch).
Furthermore, the proposed grass-sod-lined swales, riprap pads at culvert outlets,
permanent erosion control fabric and other erosion control devises that may be
utilized for side-slopes and embankments, grass scrubbing across the bottom of the
detention ponds during first flush conditions, and the water quality basins
incorporated into the detention pond designs will provide additional mechanisms for
pollutants to settle out of the stormwater runoff before flows are east and into the No.
8 Ditch.
D. Erosion Control Concept
Proposed erosion control concepts will adequately provide for the control of wind
and rainfall erosion from the proposed development. Through the construction of the
proposed erosion control concepts, the City of Fort Collins standards will be
maintained. The proposed erosion control concepts presented in the preliminary
drainage report and shown on the erosion control plan are in compliance with the
City of Fort Collins Erosion Control Criteria. Phased erosion control plans will be
provided during final design.
Erosion Control Escrow Estimate
The Erosion Control Escrow Estimate for the subject property will be provided at
final design.
REFERENCES
26
1. Storm Drainage Design Criteria and Construction Standards by the City of Fort Collins,
Colorado, May 1984, Revised January 1997, & Associated UDFCD Updates and New City
of Fort Collins Stormwater Criteria manual, adopted January, 2012, updated December 2018.
2. Erosion Control Reference Manual for Construction Sites by the City of Fort Collins,
Colorado, January 1991, Revised January 1997, & Associated UDFCD Updates and New
City of Fort Collins Stormwater Criteria manual, adopted January 2012.
3. Urban Storm Drainage Criteria Manual Volume 1; Urban Drainage and Flood Control
District, Denver, Colorado, June 2001, Revised April 2016 and August 2018.
4. Urban Storm Drainage Criteria Manual Volume 2; Urban Drainage and Flood Control
District, Denver, Colorado, June 2001, Revised April 2016 & September 2017.
5. Urban Storm Drainage Criteria Manual Volume 3, Best Management Practices; Urban
Drainage and Flood Control District, Denver, Colorado, August 2011, Revised January
2021.
6. USDA Web Soil Survey, United States Department of Agriculture, Last updated 7/31/19.
7. Project Development Plan Drainage and Erosion Control Study for the Lind Property Filing
1, Fort Collins, Colorado, May 9, 2023, by Sear Brown.
27
APPENDIX
28
APPENDIX A
29
VICINITY MAP,
SOILS MAP,
FEMA FIRMETTE
VICINITY MAP
AUGUST 16, 2023
ASPEN
SITE LOCATION
PROJECT BENCHMARK
CITY OF FORT COLLINS
BM #34-01
ELEVATION 5026.59
PROJECT BENCHMARK
CITY OF FORT COLLINS
BM #32-01
ELEVATION 5071.62
Soil Map—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 1 of 3
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
496500 496700 496900 497100 497300 497500 497700
496500 496700 496900 497100 497300 497500 497700
40° 38' 19'' N
10
5
°
2
'
2
9
'
'
W
40° 38' 19'' N
10
5
°
1
'
3
5
'
'
W
40° 37' 24'' N
10
5
°
2
'
2
9
'
'
W
40° 37' 24'' N
10
5
°
1
'
3
5
'
'
W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 400 800 1600 2400
Feet
0 100 200 400 600
Meters
Map Scale: 1:8,250 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point Features
Blowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 16, Sep 2, 2021
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Sep 20, 2015—Aug
10, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Soil Map—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 2 of 3
Map Unit Legend
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
35 Fort Collins loam, 0 to 3
percent slopes
8.0 6.1%
36 Fort Collins loam, 3 to 5
percent slopes
18.1 13.8%
48 Heldt clay loam, 0 to 3 percent
slopes
6.6 5.0%
54 Kim loam, 3 to 5 percent
slopes
0.0 0.0%
55 Kim loam, 5 to 9 percent
slopes
9.8 7.5%
95 Satanta loam, 1 to 3 percent
slopes
59.2 45.1%
96 Satanta loam, 3 to 5 percent
slopes
6.6 5.0%
103 Stoneham loam, 5 to 9 percent
slopes
23.0 17.5%
Totals for Area of Interest 131.3 100.0%
Soil Map—Larimer County Area, Colorado Sonders East
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 3 of 3
Hydrologic Soil Group—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 1 of 4
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
496500 496700 496900 497100 497300 497500 497700
496500 496700 496900 497100 497300 497500 497700
40° 38' 19'' N
10
5
°
2
'
2
9
'
'
W
40° 38' 19'' N
10
5
°
1
'
3
5
'
'
W
40° 37' 24'' N
10
5
°
2
'
2
9
'
'
W
40° 37' 24'' N
10
5
°
1
'
3
5
'
'
W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 400 800 1600 2400
Feet
0 100 200 400 600
Meters
Map Scale: 1:8,250 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Lines
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Points
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 16, Sep 2, 2021
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Sep 20, 2015—Aug
10, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Hydrologic Soil Group—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 2 of 4
Hydrologic Soil Group
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
35 Fort Collins loam, 0 to 3
percent slopes
C 8.0 6.1%
36 Fort Collins loam, 3 to 5
percent slopes
C 18.1 13.8%
48 Heldt clay loam, 0 to 3
percent slopes
C 6.6 5.0%
54 Kim loam, 3 to 5 percent
slopes
B 0.0 0.0%
55 Kim loam, 5 to 9 percent
slopes
B 9.8 7.5%
95 Satanta loam, 1 to 3
percent slopes
C 59.2 45.1%
96 Satanta loam, 3 to 5
percent slopes
B 6.6 5.0%
103 Stoneham loam, 5 to 9
percent slopes
B 23.0 17.5%
Totals for Area of Interest 131.3 100.0%
Hydrologic Soil Group—Larimer County Area, Colorado Sonders East
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 3 of 4
Description
Hydrologic soil groups are based on estimates of runoff potential. Soils are
assigned to one of four groups according to the rate of water infiltration when the
soils are not protected by vegetation, are thoroughly wet, and receive
precipitation from long-duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and
three dual classes (A/D, B/D, and C/D). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when
thoroughly wet. These consist mainly of deep, well drained to excessively
drained sands or gravelly sands. These soils have a high rate of water
transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These
consist chiefly of moderately deep or deep, moderately well drained or well
drained soils that have moderately fine texture to moderately coarse texture.
These soils have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist
chiefly of soils having a layer that impedes the downward movement of water or
soils of moderately fine texture or fine texture. These soils have a slow rate of
water transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when
thoroughly wet. These consist chiefly of clays that have a high shrink-swell
potential, soils that have a high water table, soils that have a claypan or clay
layer at or near the surface, and soils that are shallow over nearly impervious
material. These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is
for drained areas and the second is for undrained areas. Only the soils that in
their natural condition are in group D are assigned to dual classes.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
Hydrologic Soil Group—Larimer County Area, Colorado Sonders East
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 4 of 4
Wind Erodibility Group—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 1 of 3
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
496500 496700 496900 497100 497300 497500 497700
496500 496700 496900 497100 497300 497500 497700
40° 38' 19'' N
10
5
°
2
'
2
9
'
'
W
40° 38' 19'' N
10
5
°
1
'
3
5
'
'
W
40° 37' 24'' N
10
5
°
2
'
2
9
'
'
W
40° 37' 24'' N
10
5
°
1
'
3
5
'
'
W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 400 800 1600 2400
Feet
0 100 200 400 600
Meters
Map Scale: 1:8,250 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
1
2
3
4
4L
5
6
7
8
Not rated or not available
Soil Rating Lines
1
2
3
4
4L
5
6
7
8
Not rated or not available
Soil Rating Points
1
2
3
4
4L
5
6
7
8
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 16, Sep 2, 2021
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Sep 20, 2015—Aug
10, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Wind Erodibility Group—Larimer County Area, Colorado
(Sonders East)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 2 of 3
Wind Erodibility Group
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
35 Fort Collins loam, 0 to 3
percent slopes
5 8.0 6.1%
36 Fort Collins loam, 3 to 5
percent slopes
5 18.1 13.8%
48 Heldt clay loam, 0 to 3
percent slopes
6 6.6 5.0%
54 Kim loam, 3 to 5 percent
slopes
4L 0.0 0.0%
55 Kim loam, 5 to 9 percent
slopes
4L 9.8 7.5%
95 Satanta loam, 1 to 3
percent slopes
5 59.2 45.1%
96 Satanta loam, 3 to 5
percent slopes
5 6.6 5.0%
103 Stoneham loam, 5 to 9
percent slopes
6 23.0 17.5%
Totals for Area of Interest 131.3 100.0%
Description
A wind erodibility group (WEG) consists of soils that have similar properties
affecting their susceptibility to wind erosion in cultivated areas. The soils
assigned to group 1 are the most susceptible to wind erosion, and those
assigned to group 8 are the least susceptible.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Lower
Wind Erodibility Group—Larimer County Area, Colorado Sonders East
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
5/19/2022
Page 3 of 3
K Factor, Whole Soil—Larimer County Area, Colorado
(Sonders East K value rating)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/14/2023
Page 1 of 3
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
44
9
7
0
0
0
44
9
7
2
0
0
44
9
7
4
0
0
44
9
7
6
0
0
44
9
7
8
0
0
44
9
8
0
0
0
44
9
8
2
0
0
44
9
8
4
0
0
44
9
8
6
0
0
496500 496700 496900 497100 497300 497500 497700
496500 496700 496900 497100 497300 497500 497700
40° 38' 18'' N
10
5
°
2
'
2
9
'
'
W
40° 38' 18'' N
10
5
°
1
'
3
5
'
'
W
40° 37' 24'' N
10
5
°
2
'
2
9
'
'
W
40° 37' 24'' N
10
5
°
1
'
3
5
'
'
W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 350 700 1400 2100
Feet
0 100 200 400 600
Meters
Map Scale: 1:8,090 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
.02
.05
.10
.15
.17
.20
.24
.28
.32
.37
.43
.49
.55
.64
Not rated or not available
Soil Rating Lines
.02
.05
.10
.15
.17
.20
.24
.28
.32
.37
.43
.49
.55
.64
Not rated or not available
Soil Rating Points
.02
.05
.10
.15
.17
.20
.24
.28
.32
.37
.43
.49
.55
.64
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data
as of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 17, Sep 7, 2022
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Jul 2, 2021—Aug
25, 2021
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
K Factor, Whole Soil—Larimer County Area, Colorado
(Sonders East K value rating)
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/14/2023
Page 2 of 3
K Factor, Whole Soil
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
35 Fort Collins loam, 0 to 3
percent slopes
.43 8.2 6.3%
36 Fort Collins loam, 3 to 5
percent slopes
.43 18.8 14.6%
48 Heldt clay loam, 0 to 3
percent slopes
.28 4.3 3.3%
55 Kim loam, 5 to 9 percent
slopes
.28 10.4 8.1%
95 Satanta loam, 1 to 3
percent slopes
.32 58.0 44.8%
96 Satanta loam, 3 to 5
percent slopes
.32 6.9 5.4%
103 Stoneham loam, 5 to 9
percent slopes
.28 22.6 17.5%
Totals for Area of Interest 129.3 100.0%
Description
Erosion factor K indicates the susceptibility of a soil to sheet and rill erosion by
water. Factor K is one of six factors used in the Universal Soil Loss Equation
(USLE) and the Revised Universal Soil Loss Equation (RUSLE) to predict the
average annual rate of soil loss by sheet and rill erosion in tons per acre per
year. The estimates are based primarily on percentage of silt, sand, and organic
matter and on soil structure and saturated hydraulic conductivity (Ksat). Values of
K range from 0.02 to 0.69. Other factors being equal, the higher the value, the
more susceptible the soil is to sheet and rill erosion by water.
"Erosion factor Kw (whole soil)" indicates the erodibility of the whole soil. The
estimates are modified by the presence of rock fragments.
Factor K does not apply to organic horizons and is not reported for those layers.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
Layer Options (Horizon Aggregation Method): Surface Layer (Not applicable)
K Factor, Whole Soil—Larimer County Area, Colorado Sonders East K value rating
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
8/14/2023
Page 3 of 3
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250
Feet
Ü
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
Without Base Flood Elevation (BFE)
Zone A, V, A99
With BFE or DepthZone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areas
of 1% annual chance flood with average
depth less than one foot or with drainage
areas of less than one square mileZone X
Future Conditions 1% Annual
Chance Flood HazardZone X
Area with Reduced Flood Risk due to
Levee. See Notes.Zone X
Area with Flood Risk due to LeveeZone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood HazardZone D
Channel, Culvert, or Storm Sewer
Levee, Dike, or Floodwall
Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
Coastal Transect
Coastal Transect Baseline
Profile Baseline
Hydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of Study
Jurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of
digital flood maps if it is not void as described below.
The basemap shown complies with FEMA's basemap
accuracy standards
The flood hazard information is derived directly from the
authoritative NFHL web services provided by FEMA. This map
was exported on 5/19/2022 at 6:14 PM and does not
reflect changes or amendments subsequent to this date and
time. The NFHL and effective information may change or
become superseded by new data over time.
This map image is void if the one or more of the following map
elements do not appear: basemap imagery, flood zone labels,
legend, scale bar, map creation date, community identifiers,
FIRM panel number, and FIRM effective date. Map images for
unmapped and unmodernized areas cannot be used for
regulatory purposes.
Legend
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
8
B 20.2
The pin displayed on the map is an approximate
point selected by the user and does not represent
an authoritative property location.
1:6,000
105°2'36"W 40°38'26"N
105°1'58"W 40°37'59"N
Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250
Feet
Ü
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
Without Base Flood Elevation (BFE)
Zone A, V, A99
With BFE or DepthZone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areas
of 1% annual chance flood with average
depth less than one foot or with drainage
areas of less than one square mileZone X
Future Conditions 1% Annual
Chance Flood HazardZone X
Area with Reduced Flood Risk due to
Levee. See Notes.Zone X
Area with Flood Risk due to LeveeZone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood HazardZone D
Channel, Culvert, or Storm Sewer
Levee, Dike, or Floodwall
Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
Coastal Transect
Coastal Transect Baseline
Profile Baseline
Hydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of Study
Jurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of
digital flood maps if it is not void as described below.
The basemap shown complies with FEMA's basemap
accuracy standards
The flood hazard information is derived directly from the
authoritative NFHL web services provided by FEMA. This map
was exported on 5/19/2022 at 6:12 PM and does not
reflect changes or amendments subsequent to this date and
time. The NFHL and effective information may change or
become superseded by new data over time.
This map image is void if the one or more of the following map
elements do not appear: basemap imagery, flood zone labels,
legend, scale bar, map creation date, community identifiers,
FIRM panel number, and FIRM effective date. Map images for
unmapped and unmodernized areas cannot be used for
regulatory purposes.
Legend
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
8
B 20.2
The pin displayed on the map is an approximate
point selected by the user and does not represent
an authoritative property location.
1:6,000
105°2'27"W 40°38'5"N
105°1'50"W 40°37'38"N
Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250
Feet
Ü
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
Without Base Flood Elevation (BFE)
Zone A, V, A99
With BFE or DepthZone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areas
of 1% annual chance flood with average
depth less than one foot or with drainage
areas of less than one square mileZone X
Future Conditions 1% Annual
Chance Flood HazardZone X
Area with Reduced Flood Risk due to
Levee. See Notes.Zone X
Area with Flood Risk due to LeveeZone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood HazardZone D
Channel, Culvert, or Storm Sewer
Levee, Dike, or Floodwall
Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
Coastal Transect
Coastal Transect Baseline
Profile Baseline
Hydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of Study
Jurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of
digital flood maps if it is not void as described below.
The basemap shown complies with FEMA's basemap
accuracy standards
The flood hazard information is derived directly from the
authoritative NFHL web services provided by FEMA. This map
was exported on 5/19/2022 at 6:16 PM and does not
reflect changes or amendments subsequent to this date and
time. The NFHL and effective information may change or
become superseded by new data over time.
This map image is void if the one or more of the following map
elements do not appear: basemap imagery, flood zone labels,
legend, scale bar, map creation date, community identifiers,
FIRM panel number, and FIRM effective date. Map images for
unmapped and unmodernized areas cannot be used for
regulatory purposes.
Legend
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
8
B 20.2
The pin displayed on the map is an approximate
point selected by the user and does not represent
an authoritative property location.
1:6,000
105°2'16"W 40°37'53"N
105°1'39"W 40°37'26"N
Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020
30
APPENDIX B
31
RATIONAL METHOD HYDROLOGY,
HISTORIC DRAINAGE
CALCULATIONS, & STREET
CAPACITIES
1 acre = 43,560 ft2
Basin Roof Area (sqft) Asphalt Area (sqft) Concrete Area (sqft) Gravel Area (sqft) Lawn Area (sqft) Total Area Composite
No."C=0.9" "C=0.95" "C=0.9" "C=0.41" "C=0.25" (sqft) "C"
EX1 0 0 0 0 2,807,516 2,807,516 0.25
EX2 0 0 0 0 2,835,246 2,835,246 0.25
Total OFFSITE 0 0 0 0 5,642,762 5,642,762 0.25
Total Acreage 0.00 0.00 0.00 0.00 129.54 129.54
This sheet calculates the composite "C" values for the Rational Method.
Existing Weighted Runoff Coefficients
Sonders East
105-001
Aspen Engieering
9:06 AM
6/11/2024
TIME OF CONCENTRATION
2 year existing storm
Sonders East
105-001
t c = t i + t L
C f =1.00
SUB-BASIN DATA INITIAL/OVERLAND TIME TRAVEL TIME FINAL REMARKS
BASIN AREA C LENGTH SLOPE
ti LENGTH CHANNEL SLOPE VELOCITY
tL tc
NO. (ac) (ft) (%) (min) (ft) TYPE(a) (%) (ft/s) (min) (min)
1 2 3 4 5 6 7 8 10 12 13
EX1 64.45 0.25 450 1.15 32.2 700 GW 0.78 1.36 8.6 40.8
EX2 65.09 0.25 400 1.43 28.2 920 GW 1.25 1.72 8.9 37.1
Note:
a) Codes the channel type for velocity calculations.
PA = Paved, PL = Pasture & Lawns, GW = Grassed Waterway
t CC D
Si
f187 11
0 333
. ( . )
.
Aspen Engineering
9:08 AM
6/11/2024
Rational Method
Existing 2 Year Design Storm
Sonders East
105-001
Design Point Basins tc Length Type Slope Velocity Travel
Pipe
Travel tc'C Intensity Area
Direct
Runoff
Other
Runoff
Total
Runoff
Location (min)(ft)(a)(%)(ft/s)(min)(min)(min) (in/hr) (ac) (cfs) (cfs) (cfs)Remarks
EX1 EX1 40.8 -- -- -- -- 0.0 0.0 40.8 0.25 1.06 64.45 17.03 0.00 17.03
EX2 EX2 37.1 -- -- -- -- 0.0 0.0 37.1 0.25 1.12 65.09 18.30 0.00 18.30
OFFSITE
RunoffRouting Flow Time (tL)
Note:
a) Codes the channel type for velocity calculations.
PA = Paved, PL = Pasture & Lawns, GW = Grassed Waterway
Aspen Engineering
9:09 AM
6/11/2024
Basin Roof Area (sqft) Asphalt Area (sqft) Concrete Area (sqft) Gravel Area (sqft) Lawn Area (sqft) Total Area Composite
No."C=0.90" "C=0.95" "C=0.90" "C=0.41" "C=0.25" (sqft) "C"
1 0 0 0 0 25,956 25,956 0.25
2 33,000 22,818 10,861 0 130,959 197,638 0.48
3 36,000 20,804 8,460 0 104,474 169,738 0.51
4 42,000 14,522 4,452 0 54,090 115,064 0.60
5 31,680 0 0 0 77,564 109,244 0.44
6 24,000 19,317 9,230 0 56,791 109,338 0.57
7 22,500 18,528 7,890 0 58,364 107,282 0.56
8 0 9,344 4,380 0 9,788 23,512 0.65
9 18,000 18,981 8,078 0 60,832 105,890 0.54
10 18,000 16,176 7,583 0 83,613 125,371 0.47
11 27,000 11,576 6,411 0 58,483 103,470 0.54
12 14,850 14,400 6,750 0 16,840 52,840 0.71
13 36,000 36,030 11,360 0 172,307 255,697 0.47
14 58,957 30,211 9,606 0 71,817 170,591 0.64
15 0 0 12,450 0 24,547 36,997 0.47
16 30,079 27,660 11,000 0 35,084 103,822 0.69
17 31,674 20,992 9,840 0 53,650 116,156 0.61
18 0 15,104 7,080 0 16,793 38,977 0.64
18A 0 8,016 3,758 0 3,374 15,147 0.78
19 0 66,142 264,566 0 178,073 508,781 0.68
20 0 45,268 105,624 0 37,723 188,615 0.78
21 42,254 35,482 13,164 0 90,895 181,795 0.58
22 61,092 41,872 14,460 0 96,401 213,825 0.62
22A 6,585 5,152 2,415 0 8,418 22,570 0.67
23 10,336 22,992 10,778 0 43,399 87,504 0.59
24 24,621 12,842 3,159 0 11,421 52,043 0.77
25 0 4,000 1,875 0 3,019 8,894 0.70
26 33,000 10,849 3,570 0 63,220 110,639 0.53
27 0 5,808 2,723 0 5,424 13,954 0.67
28 24,621 0 3,200 0 33,864 61,685 0.54
29 99,914 25,200 16,400 0 82,036 223,550 0.67
30 33,000 3,200 1,500 0 7,640 45,340 0.79
31 34,336 21,820 8,658 0 51,680 116,494 0.62
32 0 10,192 4,778 0 11,133 26,102 0.64
33 6,000 10,432 4,890 0 10,436 31,758 0.70
34 24,000 0 0 0 21,156 45,156 0.60
35 15,000 8,032 3,765 0 19,304 46,101 0.64
36 24,000 8,032 3,765 0 21,916 57,713 0.66
37 30,000 24,778 7,431 0 67,175 129,384 0.57
38 18,000 19,202 6,447 0 76,658 120,307 0.49
39 57,420 0 1,875 0 145,620 204,915 0.44
40 12,000 8,512 3,990 0 19,530 44,032 0.62
41 25,500 19,872 9,315 0 46,530 101,217 0.61
42 36,000 0 0 0 56,816 92,816 0.50
43 0 7,840 3,675 0 11,725 23,240 0.59
44 51,000 23,677 14,104 0 106,473 195,254 0.55
45 10,500 0 0 0 66,615 77,115 0.34
46 10,890 25,281 12,193 0 37,653 86,017 0.63
47 33,000 40,790 17,713 0 112,215 203,718 0.55
48 17,856 17,302 7,365 0 24,689 67,212 0.67
49 17,677 0 0 0 61,485 79,162 0.40
50 4,500 0 0 0 27,315 31,815 0.34
51 0 0 0 0 7,069 7,069 0.25
52 0 5,136 2,408 0 4,469 12,012 0.68
OS-1 0 10,224 3,408 0 11,959 25,591 0.62
OS-2*0 8,328 2,776 0 3,518 14,622 0.77
OS-3*0 11,904 3,968 0 4,474 20,346 0.79
Developed Weighted Runoff Coefficients
Sonders East
105-001
Aspen Engineering
11:31 AM
6/12/2024
Basin Roof Area (sqft) Asphalt Area (sqft) Concrete Area (sqft) Gravel Area (sqft) Lawn Area (sqft) Total Area Composite
No."C=0.90" "C=0.95" "C=0.90" "C=0.41" "C=0.25" (sqft) "C"
OS-4*0 12,600 4,200 0 5,362 22,162 0.77
OS-5*0 6,672 2,224 0 2,808 11,704 0.77
OS-6*0 11,736 3,912 0 4,775 20,423 0.78
OS-7*0 2,352 784 0 873 4,009 0.79
OS-8*0 18,072 6,024 0 5,669 29,765 0.81
OS-9*0 10,920 3,640 0 4,671 19,231 0.77
OS-10 0 0 0 0 94,355 94,355 0.25
OS-11 0 0 0 0 92,385 92,385 0.25
OS-12 0 0 0 0 1,812,937 1,812,937 0.25
OS-13 0 0 0 0 319,757 319,757 0.25
Total SITE 1,186,842 926,991 725,927 0 5,148,060 7,987,821 0.49
Total Acreage 27.25 21.28 16.67 0.00 118.18 183.38 0.49
* Within Development Boundary
Impervious Ratio
Basin Roof Area (sqft) Asphalt Area (sqft) Concrete Area (sqft) Gravel Area (sqft) Lawn Area (sqft) Total Area Imperviousness
No.(sqft) Ratio
1 0 0 0 0 25,956 25,956 5%
2 33,000 22,818 10,861 0 130,959 197,638 35%
3 36,000 20,804 8,460 0 104,474 169,738 39%
4 42,000 14,522 4,452 0 54,090 115,064 52%
5 31,680 0 0 0 77,564 109,244 30%
6 24,000 19,317 9,230 0 56,791 109,338 48%
7 22,500 18,528 7,890 0 58,364 107,282 46%
8 0 9,344 4,380 0 9,788 23,512 60%
9 18,000 18,981 8,078 0 60,832 105,890 44%
10 18,000 16,176 7,583 0 83,613 125,371 35%
11 27,000 11,576 6,411 0 58,483 103,470 44%
12 14,850 14,400 6,750 0 16,840 52,840 67%
13 36,000 36,030 11,360 0 172,307 255,697 35%
14 58,957 30,211 9,606 0 71,817 170,591 57%
15 0 0 12,450 0 24,547 36,997 37%
16 30,079 27,660 11,000 0 35,084 103,822 65%
17 31,674 20,992 9,840 0 53,650 116,156 53%
18 0 15,104 7,080 0 16,793 38,977 59%
18A 0 8,016 3,758 0 3,374 15,147 79%
19 0 66,142 264,566 0 178,073 508,781 67%
20 0 45,268 105,624 0 37,723 188,615 81%
21 42,254 35,482 13,164 0 90,895 181,795 50%
22 61,092 41,872 14,460 0 96,401 213,825 54%
22A 6,585 5,152 2,415 0 8,418 22,570 62%
23 10,336 22,992 10,778 0 43,399 87,504 52%
24 24,621 12,842 3,159 0 11,421 52,043 74%
25 0 4,000 1,875 0 3,019 8,894 68%
26 33,000 10,849 3,570 0 63,220 110,639 43%
27 0 5,808 2,723 0 5,424 13,954 63%
28 24,621 0 3,200 0 33,864 61,685 44%
29 99,914 25,200 16,400 0 82,036 223,550 61%
30 33,000 3,200 1,500 0 7,640 45,340 77%
31 34,336 21,820 8,658 0 51,680 116,494 55%
32 0 10,192 4,778 0 11,133 26,102 59%
33 6,000 10,432 4,890 0 10,436 31,758 67%
34 24,000 0 0 0 21,156 45,156 50%
35 15,000 8,032 3,765 0 19,304 46,101 57%
36 24,000 8,032 3,765 0 21,916 57,713 60%
37 30,000 24,778 7,431 0 67,175 129,384 48%
38 18,000 19,202 6,447 0 76,658 120,307 38%
39 57,420 0 1,875 0 145,620 204,915 30%
40 12,000 8,512 3,990 0 19,530 44,032 55%
41 25,500 19,872 9,315 0 46,530 101,217 54%
42 36,000 0 0 0 56,816 92,816 38%
43 0 7,840 3,675 0 11,725 23,240 52%
44 51,000 23,677 14,104 0 106,473 195,254 46%
45 10,500 0 0 0 66,615 77,115 17%
Aspen Engineering
11:31 AM
6/12/2024
Basin Roof Area (sqft) Asphalt Area (sqft) Concrete Area (sqft) Gravel Area (sqft) Lawn Area (sqft) Total Area Composite
No."C=0.90" "C=0.95" "C=0.90" "C=0.41" "C=0.25" (sqft) "C"
46 10,890 25,281 12,193 0 37,653 86,017 57%
47 33,000 40,790 17,713 0 112,215 203,718 46%
48 17,856 17,302 7,365 0 24,689 67,212 62%
49 17,677 0 0 0 61,485 79,162 24%
50 4,500 0 0 0 27,315 31,815 17%
51 0 0 0 0 7,069 7,069 5%
52 0 5,136 2,408 0 4,469 12,012 65%
Total SITE 1,186,842 834,183 694,991 0 2,784,517 5,500,534 50%
Total Acreage 27.25 19.15 15.95 0.00 63.92 126.27
Business:
Commercial areas
Neighborhood areas
Residential:
Single-family
Multiunit (detached)
Multiunit (attached)
Half-acre lot or larger
Apartments
Industrial:
Light areas
Heavy areas
Parks, cemeteries:
Playgrounds:
Schools:
Railroad yard areas:
Undeveloped areas:
Historical Flow Analysis
Greenbelts, agricultural
Off-site flow analysis
(when land use not defined)
Streets:
Paved
Gravel (packed)
Driveways and sidewalks:
Roofs:
Lawns, sandy soil
Lawns, clayey soil
*Refer to Figures RO-3 through RO-5 in Runoff Chapter
45
0
0
100
40
90
90
5
10
50
15
2
75
*
80
80
90
95
85
*
60
Land Use or Surface Characteristics Percent Imper-viousness
Aspen Engineering
11:31 AM
6/12/2024
TIME OF CONCENTRATION
2 year design storm
Sonders East
105-001
t c = t i + t L
C f =1.00
SUB-BASIN DATA INITIAL/OVERLAND TIME TRAVEL TIME FINAL REMARKS
BASIN AREA C LENGTH SLOPE
ti LENGTH CHANNEL SLOPE VELOCITY
tL tc
NO. (ac) (ft) (%) (min) (ft) TYPE(a) (%) (ft/s) (min) (min)
1 2 3 4 5 6 7 8 10 12 13
1 0.60 0.25 141 2.0 15.0 0 PA 1.4 2.26 0.0 15.0
2 4.54 0.48 100 2.0 9.3 340 PA 0.5 1.34 4.2 13.5
3 3.90 0.51 100 2.0 8.8 562 PA 0.7 1.59 5.9 14.7
4 2.64 0.60 80 2.0 6.6 520 PA 1.0 1.91 4.5 11.2
5 2.51 0.44 100 2.0 9.8 1070 GW 1.0 1.54 11.6 21.4
6 2.51 0.57 100 2.0 7.9 600 PA 0.6 1.47 6.8 14.7
7 2.46 0.56 60 2.0 6.3 500 PA 2.0 2.72 3.1 9.3
8 0.54 0.65 20 2.0 3.0 584 PA 0.7 1.59 6.1 9.1
9 2.43 0.54 30 2.0 4.6 1010 PA 0.7 1.59 10.6 15.2
10 2.88 0.47 30 2.0 5.1 1010 PA 0.7 1.59 10.6 15.7
11 2.38 0.54 100 2.0 8.3 630 PA 1.6 2.42 4.3 12.7
12 1.21 0.71 30 2.0 3.2 650 PA 1.6 2.42 4.5 7.7
13 5.87 0.47 70 2.0 7.8 662 PA 1.0 1.91 5.8 13.6
14 3.92 0.64 120 2.0 7.6 889 PA 0.6 1.47 10.1 17.7
15 0.85 0.47 185 2.0 12.7 0 PA 2.0 2.72 0.0 12.7
16 2.38 0.69 249 3.0 8.3 705 PA 1.1 2.00 5.9 14.2
17 2.67 0.61 70 2.0 6.1 590 PA 0.6 1.47 6.7 12.8
18 0.89 0.64 20 2.0 3.1 805 PA 0.6 1.47 9.1 12.2
18A 0.35 0.78 20 2.0 2.1 501 PA 0.6 1.47 5.7 7.8
19 11.68 0.68 100 2.0 6.3 598 PA 1.5 2.35 4.2 10.5
20 4.33 0.78 211 3.0 6.0 600 PA 0.6 1.47 6.8 12.8
21 4.17 0.58 100 2.0 7.6 700 PA 0.6 1.47 8.0 15.6
22 4.91 0.62 60 2.0 5.6 911 PA 0.6 1.47 10.4 15.9
22A 0.52 0.67 20 2.0 2.9 1336 PA 0.6 1.47 15.2 18.0
23 2.01 0.59 80 2.0 6.8 537 PA 1.5 2.35 3.8 10.6
24 1.19 0.77 20 2.0 2.2 235 PA 2.5 3.05 1.3 5.0
25 0.20 0.70 100 2.0 5.9 300 PA 2.0 2.72 1.8 7.7
26 2.54 0.53 20 2.0 3.8 260 PA 2.0 2.72 1.6 5.4
27 0.32 0.67 100 3.0 5.6 330 GW 1.0 1.54 3.6 9.2
28 1.42 0.54 100 2.0 8.3 500 GW 0.6 1.19 7.0 15.3
29 5.13 0.67 80 2.0 5.7 500 PA 1.0 1.91 4.4 10.1
30 1.04 0.79 110 2.0 4.8 514 PA 0.9 1.81 4.7 9.5
31 2.67 0.62 20 2.0 3.2 245 PA 0.6 1.47 2.8 6.0
32 0.60 0.64 20 2.0 3.0 245 PA 0.6 1.47 2.8 5.8
33 0.73 0.70 80 2.0 5.3 233 PA 0.6 1.47 2.6 7.9
34 1.04 0.60 55 2.0 5.6 429 PA 3.0 3.35 2.1 7.7
35 1.06 0.64 55 2.0 5.1 429 PA 3.0 3.35 2.1 7.2
36 1.32 0.66 90 2.0 6.2 654 PA 2.8 3.23 3.4 9.6
37 2.97 0.57 100 2.0 7.8 621 PA 1.2 2.09 4.9 12.8
38 2.76 0.49 80 4.0 6.4 830 GW 0.5 1.09 12.7 19.1
39 4.70 0.44 80 2.0 8.8 255 PA 0.6 1.47 2.9 11.7
40 1.01 0.62 80 2.0 6.4 621 PA 1.5 2.35 4.4 10.8
41 2.32 0.61 100 2.0 7.3 374 GW 2.3 2.33 2.7 9.9
42 2.13 0.50 20 2.0 4.0 437 PA 1.3 2.14 3.4 7.4
43 0.53 0.59 100 2.0 7.6 587 PA 2.0 2.72 3.6 11.2
44 4.48 0.55 80 2.0 7.3 399 GW 2.0 2.18 3.1 10.3
45 1.77 0.34 20 2.0 5.1 914 PA 1.0 1.91 8.0 13.0
46 1.97 0.63 20 2.0 3.1 1243 PA 1.2 2.09 9.9 13.0
47 4.68 0.55 100 2.0 8.1 606 PA 1.9 2.65 3.8 11.9
48 1.54 0.67 80 4.0 4.5 340 PA 0.5 1.34 4.2 8.7
49 1.82 0.40 80 4.0 7.4 340 PA 0.5 1.34 4.2 11.7
50 0.73 0.34 80 4.0 8.0 340 PA 0.5 1.34 4.2 12.2
51 0.16 0.25 20 2.0 5.6 320 PA 0.5 1.34 4.0 9.6
52 0.28 0.68 20 2.0 5.6 300 PA 0.5 1.34 3.7 9.4
OS-1 0.59 0.62 30 2.0 3.9 250 PA 0.5 1.34 3.1 7.1
OS-2* 0.34 0.77 30 2.0 2.7 90 PA 0.5 1.34 1.1 5.0
OS-3* 0.47 0.79 30 2.0 2.6 213 PA 0.5 1.34 2.7 5.2
OS-4* 0.51 0.77 30 2.0 2.7 250 PA 0.5 1.34 3.1 5.8
OS-5* 0.27 0.77 30 2.0 2.7 142 PA 0.5 1.34 1.8 5.0
OS-6* 0.47 0.78 30 2.0 2.6 300 PA 0.5 1.34 3.7 6.4
OS-7* 0.09 0.79 30 2.0 2.5 36 PA 0.5 1.34 0.4 5.0
OS-8* 0.68 0.81 30 2.0 2.4 400 PA 0.5 1.34 5.0 7.4
Aspen Engineering
11:36 AM
6/12/2024
TIME OF CONCENTRATION
2 year design storm
Sonders East
105-001
t c = t i + t L
C f =1.00
SUB-BASIN DATA INITIAL/OVERLAND TIME TRAVEL TIME FINAL REMARKS
BASIN AREA C LENGTH SLOPE
ti LENGTH CHANNEL SLOPE VELOCITY
tL tc
NO. (ac) (ft) (%) (min) (ft) TYPE(a) (%) (ft/s) (min) (min)
1 2 3 4 5 6 7 8 10 12 13
OS-9* 0.44 0.77 30 2.0 2.7 230 PA 0.5 1.34 2.9 5.5
OS-10 2.17 0.25 300 3.0 19.1 1260 GW 0.4 0.97 21.6 40.7
OS-11 2.12 0.25 N/A N/A N/A N/A N/A N/A N/A N/A N/A
OS-12 41.62 0.25 500 0.5 44.8 2300 GW 0.2 0.69 55.6 100.4
OS-13 7.34 0.25 N/A N/A N/A N/A N/A N/A N/A N/A N/A
Note:
a) Codes the channel type for velocity calculations.
PA = Paved, PL = Pasture & Lawns, GW = Grassed Waterway
Aspen Engineering
11:36 AM
6/12/2024
Rational Method
2 Year Design Storm
Sonders East
105-001
Design Point Basins tc Length Type Slope Velocity Travel
Pipe
Travel tc'C Intensity Area
Direct
Runoff
Other
Runoff
Total
Runoff
Location (min)(ft)(a)(%)(ft/s)(min)(min)(min)(in/hr)(ac)(cfs)(cfs)(cfs)
1 1 15.0 -- -- -- -- 0.0 0.0 15.0 0.25 1.87 0.60 0.28 0.00 0.28
2 2 13.5 -- 0.0 0.0 13.5 0.48 1.95 4.54 4.21 0.00 4.21
3 3 14.7 -- 0.0 0.0 14.7 0.51 1.88 3.90 3.72 0.00 3.72
4 4 11.2 -- 0.0 0.0 11.2 0.60 2.11 2.64 3.35 0.00 3.35
5 5 21.4 -- 0.0 0.0 21.4 0.44 1.55 2.51 1.71 0.00 1.71
6 6 14.7 -- 0.0 0.0 14.7 0.57 1.89 2.51 2.71 0.00 2.71
7 7 9.3 -- 0.0 0.0 9.3 0.56 2.27 2.46 3.11 0.00 3.11
8 8 9.1 -- 0.0 0.0 9.1 0.65 2.29 0.54 0.80 0.00 0.80
9 9 15.2 -- 0.0 0.0 15.2 0.54 1.86 2.43 2.42 0.00 2.42
10 10 15.7 -- 0.0 0.0 15.7 0.47 1.83 2.88 2.49 0.00 2.49
11 11 12.7 -- 0.0 0.0 12.7 0.54 2.01 2.38 2.56 0.00 2.56
12 12 7.7 -- 0.0 0.0 7.7 0.71 2.46 1.21 2.11 0.00 2.11
13 13 13.6 -- 0.0 0.0 13.6 0.47 1.95 5.87 5.36 0.00 5.36
14 14 17.7 -- 0.0 0.0 17.7 0.64 1.72 3.92 4.28 0.00 4.28
15 15 12.7 -- 0.0 0.0 12.7 0.47 2.00 0.85 0.80 0.00 0.80
16 16 14.2 -- 0.0 0.0 14.2 0.69 1.91 2.38 3.16 0.00 3.16
17 17 12.8 -- 0.0 0.0 12.8 0.61 2.00 2.67 3.24 0.00 3.24
18 18 12.2 -- 0.0 0.0 12.2 0.64 2.04 0.89 1.16 0.00 1.16
18A 18A 7.8 -- 0.0 0.0 7.8 0.78 2.44 0.35 0.66 0.00 0.66
19 19 10.5 -- 0.0 0.0 10.5 0.68 2.17 11.68 17.18 0.00 17.18
20 20 12.8 -- 0.0 0.0 12.8 0.78 2.00 4.33 6.76 0.00 6.76
21 21 15.6 -- 0.0 0.0 15.6 0.58 1.83 4.17 4.48 0.00 4.48
22 22 15.9 -- 0.0 0.0 15.9 0.62 1.82 4.91 5.50 0.00 5.50
22A 22A 18.0 -- 0.0 0.0 18.0 0.67 1.70 0.52 0.59 0.00 0.59
23 23 10.6 -- 0.0 0.0 10.6 0.59 2.16 2.01 2.56 0.00 2.56
24 24 5.0 -- 0.0 0.0 5.0 0.77 2.85 1.19 2.62 0.00 2.62
25 25 7.7 -- 0.0 0.0 7.7 0.70 2.45 0.20 0.35 0.00 0.35
26 26 5.4 -- 0.0 0.0 5.4 0.53 2.79 2.54 3.78 0.00 3.78
27 27 9.2 -- 0.0 0.0 9.2 0.67 2.29 0.32 0.49 0.00 0.49
28 28 15.3 -- 0.0 0.0 15.3 0.54 1.85 1.42 1.43 0.00 1.43
29 29 10.1 -- 0.0 0.0 10.1 0.67 2.20 5.13 7.53 0.00 7.53
30 30 9.5 -- 0.0 0.0 9.5 0.79 2.26 1.04 1.86 0.00 1.86
31 31 6.0 -- 0.0 0.0 6.0 0.62 2.69 2.67 4.47 0.00 4.47
32 32 5.8 -- 0.0 0.0 5.8 0.64 2.71 0.60 1.04 0.00 1.04
33 33 7.9 -- 0.0 0.0 7.9 0.70 2.43 0.73 1.24 0.00 1.24
34 34 7.7 -- 0.0 0.0 7.7 0.60 2.45 1.04 1.52 0.00 1.52
35 35 7.2 -- 0.0 0.0 7.2 0.64 2.51 1.06 1.69 0.00 1.69
36 36 9.6 -- 0.0 0.0 9.6 0.66 2.25 1.32 1.97 0.00 1.97
37 37 12.8 -- 0.0 0.0 12.8 0.57 2.00 2.97 3.39 0.00 3.39
38 38 19.1 -- 0.0 0.0 19.1 0.49 1.65 2.76 2.25 0.00 2.25
39 39 11.7 -- 0.0 0.0 11.7 0.44 2.07 4.70 4.27 0.00 4.27
40 40 10.8 -- 0.0 0.0 10.8 0.62 2.14 1.01 1.35 0.00 1.35
41 41 9.9 -- 0.0 0.0 9.9 0.61 2.22 2.32 3.15 0.00 3.15
42 42 7.4 -- 0.0 0.0 7.4 0.50 2.49 2.13 2.67 0.00 2.67
43 43 11.2 -- 0.0 0.0 11.2 0.59 2.11 0.53 0.66 0.00 0.66
44 44 10.3 -- 0.0 0.0 10.3 0.55 2.18 4.48 5.39 0.00 5.39
45 45 13.0 -- 0.0 0.0 13.0 0.34 1.98 1.77 1.19 0.00 1.19
46 46 13.0 -- 0.0 0.0 13.0 0.63 1.98 1.97 2.47 0.00 2.47
47 47 11.9 -- 0.0 0.0 11.9 0.55 2.05 4.68 5.30 0.00 5.30
RunoffRouting Flow Time (tL)
Aspen Engineering
11:39 AM
6/12/2024
Rational Method
2 Year Design Storm
Sonders East
105-001
Design Point Basins tc Length Type Slope Velocity Travel
Pipe
Travel tc'C Intensity Area
Direct
Runoff
Other
Runoff
Total
Runoff
Location (min)(ft)(a)(%)(ft/s)(min)(min)(min)(in/hr)(ac)(cfs)(cfs)(cfs)
RunoffRouting Flow Time (tL)
48 48 8.7 -- 0.0 0.0 8.7 0.67 2.34 1.54 2.43 0.00 2.43
49 49 11.7 -- 0.0 0.0 11.7 0.40 2.07 1.82 1.49 0.00 1.49
50 50 12.2 -- 0.0 0.0 12.2 0.34 2.03 0.73 0.51 0.00 0.51
51 51 9.6 -- 0.0 0.0 9.6 0.25 2.24 0.16 0.09 0.00 0.09
52 52 9.4 -- 0.0 0.0 9.4 0.68 2.27 0.28 0.43 0.00 0.43
OS-1 OS-1 7.1 -- 0.0 0.0 7.1 0.62 2.54 0.59 0.92 0.00 0.92
OS-2* OS-2* 5.0 -- 0.0 0.0 5.0 0.77 2.85 0.34 0.74 0.00 0.74
OS-3* OS-3* 5.2 -- 0.0 0.0 5.2 0.79 2.81 0.47 1.03 0.00 1.03
OS-4* OS-4* 5.8 -- 0.0 0.0 5.8 0.77 2.72 0.51 1.07 0.00 1.07
OS-5* OS-5* 5.0 -- 0.0 0.0 5.0 0.77 2.85 0.27 0.59 0.00 0.59
OS-6* OS-6* 6.4 -- 0.0 0.0 6.4 0.78 2.63 0.47 0.96 0.00 0.96
OS-7* OS-7* 5.0 -- 0.0 0.0 5.0 0.79 2.85 0.09 0.21 0.00 0.21
OS-8* OS-8* 7.4 -- 0.0 0.0 7.4 0.81 2.49 0.68 1.37 0.00 1.37
OS-9* OS-9* 5.5 -- 0.0 0.0 5.5 0.77 2.76 0.44 0.94 0.00 0.94
OS-10 OS-10 40.7 -- 0.0 0.0 40.7 0.25 1.06 2.17 0.57 0.00 0.57
OS-11 OS-11 N/A -- 0.0 0.0 N/A N/A N/A N/A N/A N/A
OS-12 OS-12 100.4 -- 0.0 0.0 100.4 0.25 0.56 41.62 5.81 0.00 5.81
OS-13 OS-13 N/A -- 0.0 0.0 N/A N/A N/A N/A N/A N/A
Note:
a) Codes the channel type for velocity calculations.
PA = Paved, PL = Pasture & Lawns, GW = Grassed Waterway
Aspen Engineering
11:39 AM
6/12/2024
TIME OF CONCENTRATION
100 year design storm
Sonders East
105-001
t c = t i + t L
C f =1.25
SUB-BASIN DATA INITIAL/OVERLAND TIME TRAVEL TIME FINAL REMARKS
BASIN AREA C LENGTH SLOPE
ti LENGTH CHANNEL SLOPE VELOCITY
tL tc
NO. (ac) (ft) (%) (min) (ft) TYPE(a) (%) (ft/s) (min) (min)
1 2 3 4 5 6 7 8 10 12 13
1 0.60 0.25 141 2.0 13.9 0 PA 1.4 2.26 0.0 13.9
2 4.54 0.48 100 2.0 7.5 340 PA 0.5 1.34 4.2 11.8
3 3.90 0.51 100 2.0 6.9 562 PA 0.7 1.59 5.9 12.8
4 2.64 0.60 80 2.0 4.6 520 PA 1 1.91 4.5 9.2
5 2.51 0.44 100 2.0 8.2 1070 GW 1 1.54 11.6 19.8
6 2.51 0.57 100 2.0 5.7 600 PA 0.6 1.47 6.8 12.5
7 2.46 0.56 60 2.0 4.7 500 PA 2 2.72 3.1 7.7
8 0.54 0.65 20 2.0 1.9 584 PA 0.7 1.59 6.1 8.0
9 2.43 0.54 30 2.0 3.5 1010 PA 0.7 1.59 10.6 14.1
10 2.88 0.47 30 2.0 4.1 1010 PA 0.7 1.59 10.6 14.7
11 2.38 0.54 100 2.0 6.3 630 PA 1.6 2.42 4.3 10.7
12 1.21 0.71 30 2.0 1.8 650 PA 1.6 2.42 4.5 6.2
13 5.87 0.47 70 2.0 6.4 662 PA 1 1.91 5.8 12.2
14 3.92 0.64 120 2.0 5.0 889 PA 0.6 1.47 10.1 15.1
15 0.85 0.47 185 2.0 10.4 0 PA 2 2.72 0.0 10.4
16 2.38 0.69 249 2.0 5.5 705 PA 1.1 2.00 5.9 11.3
17 2.67 0.61 70 2.0 4.2 590 PA 0.6 1.47 6.7 10.9
18 0.89 0.64 20 2.0 2.0 805 PA 0.6 1.47 9.1 11.1
18A 0.35 0.78 20 2.0 0.8 501 PA 0.6 1.47 5.7 6.5
19 11.68 0.68 100 2.0 3.7 598 PA 1.5 2.35 4.2 8.0
20 4.33 0.78 211 2.0 2.6 600 PA 0.6 1.47 6.8 9.5
21 4.17 0.58 100 2.0 5.5 700 PA 0.6 1.47 8.0 13.4
22 4.91 0.62 60 2.0 3.8 911 PA 0.6 1.47 10.4 14.1
22A 0.52 0.67 20 2.0 1.8 1336 PA 0.6 1.47 15.2 16.9
23 2.01 0.59 80 2.0 4.8 537 PA 1.5 2.35 3.8 8.6
24 1.19 0.77 20 2.0 0.9 235 PA 2.5 3.05 1.3 5.0
25 0.20 0.70 100 2.0 3.3 300 PA 2 2.72 1.8 5.1
26 2.54 0.53 20 2.0 2.9 260 PA 2 2.72 1.6 5.0
27 0.32 0.67 100 2.0 3.9 330 GW 1 1.54 3.6 7.5
28 1.42 0.54 100 2.0 6.3 500 GW 0.6 1.19 7.0 13.2
29 5.13 0.67 80 2.0 3.5 500 PA 1 1.91 4.4 7.9
30 1.04 0.79 110 2.0 1.7 514 PA 0.9 1.81 4.7 6.4
31 2.67 0.62 20 2.0 2.1 245 PA 0.6 1.47 2.8 5.0
32 0.60 0.64 20 2.0 2.0 245 PA 0.6 1.47 2.8 5.0
33 0.73 0.70 80 2.0 2.9 233 PA 0.6 1.47 2.6 5.6
34 1.04 0.60 55 2.0 3.9 429 PA 3 3.35 2.1 6.1
35 1.06 0.64 55 2.0 3.4 429 PA 3 3.35 2.1 5.5
36 1.32 0.66 90 2.0 3.9 654 PA 2.8 3.23 3.4 7.2
37 2.97 0.57 100 2.0 5.7 621 PA 1.2 2.09 4.9 10.7
38 2.76 0.49 80 2.0 6.4 830 GW 0.5 1.09 12.7 19.1
39 4.70 0.44 80 2.0 7.3 255 PA 0.6 1.47 2.9 10.2
40 1.01 0.62 80 2.0 4.3 621 PA 1.5 2.35 4.4 8.7
41 2.32 0.61 100 2.0 5.0 374 GW 2.3 2.33 2.7 7.7
42 2.13 0.50 20 2.0 3.1 437 PA 1.25 2.14 3.4 6.5
43 0.53 0.59 100 2.0 5.4 587 PA 2 2.72 3.6 9.0
44 4.48 0.55 80 2.0 5.5 399 GW 2 2.18 3.1 8.5
45 1.77 0.34 20 2.0 4.5 914 PA 1 1.91 8.0 12.5
46 1.97 0.63 20 2.0 2.1 1243 PA 1.2 2.09 9.9 12.0
47 4.68 0.55 100 2.0 6.1 606 PA 1.9 2.65 3.8 9.9
48 1.54 0.67 80 2.0 3.4 340 PA 0.5 1.34 4.2 7.7
49 1.82 0.40 80 2.0 8.0 340 PA 0.5 1.34 4.2 12.3
50 0.73 0.34 80 2.0 8.0 340 PA 0.5 1.34 4.2 12.3
51 0.16 0.25 20 2.0 8.0 320 PA 0.5 1.34 4.0 12.0
52 0.28 0.68 20 2.0 1.7 300 PA 0.5 1.34 3.7 5.4
OS-1 0.59 0.62 80 2.0 4.4 90 PA 0.5 1.34 1.1 5.5
OS-2* 0.34 0.77 80 2.0 1.8 213 PA 0.5 1.34 2.7 5.0
OS-3* 0.47 0.79 80 2.0 1.6 250 PA 0.5 1.34 3.1 5.0
OS-4* 0.51 0.77 80 2.0 1.8 142 PA 0.5 1.34 1.8 5.0
OS-5* 0.27 0.77 80 2.0 1.8 300 PA 0.5 1.34 3.7 5.5
OS-6* 0.47 0.78 80 2.0 1.7 36 PA 0.5 1.34 0.4 5.0
OS-7* 0.09 0.79 80 2.0 1.5 400 PA 0.5 1.34 5.0 6.5
OS-8* 0.68 0.81 80 2.0 1.3 230 PA 0.5 1.34 2.9 5.0
OS-9* 0.44 0.77 80 2.0 1.8 1260 GW 0.4 0.97 21.6 23.4
OS-10 2.17 0.25 80 2.0 10.5 N/A N/A N/A 0.00
OS-11 2.12 0.25 80 2.0 10.5 2300 GW 0.5 1.09 35.2 45.7
OS-12 41.62 0.25 80 2.0 10.5 N/A N/A 0.5 0.00 N/A N/A
Aspen Engineering
11:34 AM
6/12/2024
TIME OF CONCENTRATION
100 year design storm
Sonders East
105-001
t c = t i + t L
C f =1.25
SUB-BASIN DATA INITIAL/OVERLAND TIME TRAVEL TIME FINAL REMARKS
BASIN AREA C LENGTH SLOPE
ti LENGTH CHANNEL SLOPE VELOCITY
tL tc
NO. (ac) (ft) (%) (min) (ft) TYPE(a) (%) (ft/s) (min) (min)
1 2 3 4 5 6 7 8 10 12 13
OS-13 7.34 0.25 80 2.0 10.5 0 0 0.5 0.00 0.0 10.5
Note:
a) Codes the channel type for velocity calculations.
PA = Paved, PL = Pasture & Lawns, GW = Grassed Waterway
Aspen Engineering
11:34 AM
6/12/2024
Design Point Basins tc Length Type Slope Velocity Travel
Pipe
Travel tc'C C*Cf Intensity Area
Direct
Runoff
Other
Runoff
Total
Runoff
Location (min)(ft)(a)(%)(ft/s)(min)(min)(min)(in/hr)(ac)(cfs)(cfs)(cfs)
1 1 13.9 -- -- -- -- 0.0 13.9 0.25 0.31 6.74 0.60 1.25 0.00 1.25
2 2 11.8 -- -- -- -- 0.0 11.8 0.48 0.59 7.22 4.54 19.45 0.00 19.45
3 3 12.8 -- -- -- -- 0.0 12.8 0.51 0.63 6.96 3.90 17.16 0.00 17.16
4 4 9.2 -- -- -- -- 0.0 9.2 0.60 0.75 7.99 2.64 15.86 0.00 15.86
5 5 19.8 -- -- -- -- 0.0 19.8 0.44 0.55 5.63 2.51 7.75 0.00 7.75
6 6 12.5 -- -- -- -- 0.0 12.5 0.57 0.71 7.03 2.51 12.59 0.00 12.59
7 7 7.7 -- -- -- -- 0.0 7.7 0.56 0.69 8.56 2.46 14.62 0.00 14.62
8 8 8.0 -- -- -- -- 0.0 8.0 0.65 0.81 8.43 0.54 3.69 0.00 3.69
9 9 14.1 -- -- -- -- 0.0 14.1 0.54 0.67 6.69 2.43 10.89 0.00 10.89
10 10 14.7 -- -- -- -- 0.0 14.7 0.47 0.59 6.57 2.88 11.18 0.00 11.18
11 11 10.7 -- -- -- -- 0.0 10.7 0.54 0.67 7.52 2.38 12.01 0.00 12.01
12 12 6.2 -- -- -- -- 0.0 6.2 0.71 0.88 9.26 1.21 9.92 0.00 9.92
13 13 12.2 -- -- -- -- 0.0 12.2 0.47 0.59 7.12 5.87 24.49 0.00 24.49
14 14 15.1 -- -- -- -- 0.0 15.1 0.64 0.79 6.50 3.92 20.22 0.00 20.22
15 15 10.4 -- -- -- -- 0.0 10.4 0.47 0.59 7.60 0.85 3.78 0.00 3.78
16 16 11.3 -- -- -- -- 0.0 11.3 0.69 0.87 7.33 2.38 15.15 0.00 15.15
17 17 10.9 -- -- -- -- 0.0 10.9 0.61 0.76 7.45 2.67 15.11 0.00 15.11
18 18 11.1 -- -- -- -- 0.0 11.1 0.64 0.80 7.38 0.89 5.28 0.00 5.28
18A 18A 6.5 -- -- -- -- 0.0 6.5 0.78 0.98 9.12 0.35 3.10 0.00 3.10
19 19 8.0 -- -- -- -- 0.0 8.0 0.68 0.85 8.46 11.68 83.82 0.00 83.82
20 20 9.5 -- -- -- -- 0.0 9.5 0.78 0.98 7.90 4.33 33.43 0.00 33.43
21 21 13.4 -- -- -- -- 0.0 13.4 0.58 0.73 6.83 4.17 20.84 0.00 20.84
22 22 14.1 -- -- -- -- 0.0 14.1 0.62 0.77 6.69 4.91 25.30 0.00 25.30
22A 22A 16.9 -- -- -- -- 0.0 16.9 0.67 0.84 6.13 0.52 2.66 0.00 2.66
23 23 8.6 -- -- -- -- 0.0 8.6 0.59 0.74 8.20 2.01 12.17 0.00 12.17
24 24 5.0 -- -- -- -- 0.0 5.0 0.77 0.96 9.95 1.19 11.44 0.00 11.44
25 25 5.1 -- -- -- -- 0.0 5.1 0.70 0.88 9.86 0.20 1.77 0.00 1.77
26 26 5.0 -- -- -- -- 0.0 5.0 0.53 0.67 9.95 2.54 16.85 0.00 16.85
27 27 7.5 -- -- -- -- 0.0 7.5 0.67 0.84 8.66 0.32 2.32 0.00 2.32
28 28 13.2 -- -- -- -- 0.0 13.2 0.54 0.68 6.87 1.42 6.61 0.00 6.61
29 29 7.9 -- -- -- -- 0.0 7.9 0.67 0.83 8.49 5.13 36.31 0.00 36.31
30 30 6.4 -- -- -- -- 0.0 6.4 0.79 0.99 9.17 1.04 9.47 0.00 9.47
31 31 5.0 -- -- -- -- 0.0 5.0 0.62 0.78 9.95 2.67 20.66 0.00 20.66
32 32 5.0 -- -- -- -- 0.0 5.0 0.64 0.80 9.95 0.60 4.79 0.00 4.79
33 33 5.6 -- -- -- -- 0.0 5.6 0.70 0.88 9.61 0.73 6.16 0.00 6.16
34 34 6.1 -- -- -- -- 0.0 6.1 0.60 0.74 9.36 1.04 7.22 0.00 7.22
35 35 5.5 -- -- -- -- 0.0 5.5 0.64 0.80 9.67 1.06 8.14 0.00 8.14
36 36 7.2 -- -- -- -- 0.0 7.2 0.66 0.83 8.77 1.32 9.59 0.00 9.59
37 37 10.7 -- -- -- -- 0.0 10.7 0.57 0.72 7.52 2.97 15.97 0.00 15.97
38 38 19.1 -- -- -- -- 0.0 19.1 0.49 0.62 5.74 2.76 9.79 0.00 9.79
39 39 10.2 -- -- -- -- 0.0 10.2 0.44 0.55 7.65 4.70 19.70 0.00 19.70
40 40 8.7 -- -- -- -- 0.0 8.7 0.62 0.78 8.17 1.01 6.41 0.00 6.41
41 41 7.7 -- -- -- -- 0.0 7.7 0.61 0.76 8.59 2.32 15.24 0.00 15.24
42 42 6.5 -- -- -- -- 0.0 6.5 0.50 0.63 9.11 2.13 12.18 0.00 12.18
43 43 9.0 -- -- -- -- 0.0 9.0 0.59 0.74 8.06 0.53 3.17 0.00 3.17
44 44 8.5 -- -- -- -- 0.0 8.5 0.55 0.69 8.24 4.48 25.48 0.00 25.48
45 45 12.5 -- -- -- -- 0.0 12.5 0.34 0.42 7.04 1.77 5.27 0.00 5.27
46 46 12.0 -- -- -- -- 0.0 12.0 0.63 0.79 7.16 1.97 11.14 0.00 11.14
47 47 9.9 -- -- -- -- 0.0 9.9 0.55 0.69 7.75 4.68 25.01 0.00 25.01
48 48 7.7 -- -- -- -- 0.0 7.7 0.67 0.84 8.59 1.54 11.17 0.00 11.17
49 49 12.3 -- -- -- -- 0.0 12.3 0.40 0.49 7.09 1.82 6.36 0.00 6.36
50 50 12.3 -- -- -- -- 0.0 12.3 0.34 0.43 7.09 0.73 2.21 0.00 2.21
51 51 12.0 -- -- -- -- 0.0 12.0 0.25 0.31 7.15 0.16 0.36 0.00 0.36
52 52 5.4 -- -- -- -- 0.0 5.4 0.68 0.85 9.71 0.28 2.28 0.00 2.28
OS-1 OS-1 5.4 -- -- -- -- 0.0 5.4 0.62 0.77 9.71 0.59 4.40 0.00 4.40
OS-2* OS-2* 5.5 -- -- -- -- 0.0 5.5 0.62 0.77 9.66 0.59 4.37 0.00 4.37
OS-3* OS-3* 5.0 -- -- -- -- 0.0 5.0 0.77 0.97 9.95 0.34 3.22 0.00 3.22
OS-4* OS-4* 5.0 -- -- -- -- 0.0 5.0 0.79 0.98 9.95 0.47 4.57 0.00 4.57
OS-5* OS-5* 5.0 -- -- -- -- 0.0 5.0 0.77 0.96 9.95 0.51 4.88 0.00 4.88
OS-6* OS-6* 5.5 -- -- -- -- 0.0 5.5 0.77 0.97 9.64 0.27 2.50 0.00 2.50
OS-7* OS-7* 5.0 -- -- -- -- 0.0 5.0 0.78 0.97 9.95 0.47 4.53 0.00 4.53
OS-8* OS-8* 6.5 -- -- -- -- 0.0 6.5 0.79 0.98 9.12 0.09 0.83 0.00 0.83
OS-9* OS-9* 5.0 -- -- -- -- 0.0 5.0 0.81 1.00 9.95 0.68 6.80 0.00 6.80
OS-10 OS-10 23.4 -- -- -- -- 0.0 23.4 0.77 0.96 5.16 0.44 2.19 0.00 2.19
OS-11 OS-11 0.0 -- -- -- -- 0.0 0.0 0.25 0.31 13.96 2.17 9.45 0.00 N/A
OS-12 OS-12 45.7 -- -- -- -- 0.0 45.7 0.25 0.31 3.43 2.12 2.27 0.00 2.27
OS-13 OS-13 N/A -- -- -- -- 0.0 0.25 0.31 FALSE 41.62 0.00 0.00 N/A
Routing Flow Time (tL) Runoff
Rational Method
100 Year Design Storm
Sonders East
105-001
Aspen Engineering 11:45 AM
6/12/2024
Design Point Basin(s) Area (acre)
Composite
"C"
Q2
(cfs)
Q100
(cfs)
1 1 0.60 0.25 0.28 1.25
2 2 4.54 0.48 4.21 19.45
3 3 3.90 0.51 3.72 17.16
4 4 2.64 0.60 3.35 15.86
5 5 2.51 0.44 1.71 7.75
6 6 2.51 0.57 2.71 12.59
7 7 2.46 0.56 3.11 14.62
8 8 0.54 0.65 0.80 3.69
9 9 2.43 0.54 2.42 10.89
10 10 2.88 0.47 2.49 11.18
11 11 2.38 0.54 2.56 12.01
12 12 1.21 0.71 2.11 9.92
13 13 5.87 0.47 5.36 24.49
14 14 3.92 0.64 4.28 20.22
15 15 0.85 0.47 0.80 3.78
16 16 2.38 0.69 3.16 15.15
17 17 2.67 0.61 3.24 15.11
18 18 0.89 0.64 1.16 5.28
18A 18A 0.35 0.78 0.66 3.10
19 19 11.68 0.68 17.18 83.82
20 20 4.33 0.78 6.76 33.43
21 21 4.17 0.58 4.48 20.84
22 22 4.91 0.62 5.50 25.30
22A 22A 0.52 0.67 0.59 2.66
23 23 2.01 0.59 2.56 12.17
24 24 1.19 0.77 2.62 11.44
25 25 0.20 0.70 0.35 1.77
26 26 2.54 0.53 3.78 16.85
27 27 0.32 0.67 0.49 2.32
28 28 1.42 0.54 1.43 6.61
29 29 5.13 0.67 7.53 36.31
30 30 1.04 0.79 1.86 9.47
31 31 2.67 0.62 4.47 20.66
32 32 0.60 0.64 1.04 4.79
33 33 0.73 0.70 1.24 6.16
34 34 1.04 0.60 1.52 7.22
35 35 1.06 0.64 1.69 8.14
36 36 1.32 0.66 1.97 9.59
37 37 2.97 0.57 3.39 15.97
38 38 2.76 0.49 2.25 9.79
39 39 4.70 0.44 4.27 19.70
40 40 1.01 0.62 1.35 6.41
Sonders East
105-001
Developed Site Hydrology
ASPEN ENGINEERING
9:32 AM
6/13/2024
Design Point Basin(s) Area (acre)
Composite
"C"
Q2
(cfs)
Q100
(cfs)
Sonders East
105-001
Developed Site Hydrology
41 41 2.32 0.61 3.15 15.24
42 42 2.13 0.50 2.67 12.18
43 43 0.53 0.59 0.66 3.17
44 44 4.48 0.55 5.39 25.48
45 45 1.77 0.34 1.19 5.27
46 46 1.97 0.63 2.47 11.14
47 47 4.68 0.55 5.30 25.01
48 48 1.54 0.67 2.43 11.17
49 49 1.82 0.40 1.49 6.36
50 50 0.73 0.34 0.51 2.21
51 51 0.16 0.25 0.09 0.36
52 52 0.28 0.68 0.43 2.28
OFF-SITE BASINS * Basins in Development Boundary
OS-1 OS-1 0.59 0.62 0.92 4.40
OS-2* OS-2* 0.34 0.77 0.74 4.37
OS-3* OS-3* 0.47 0.79 1.03 3.22
OS-4* OS-4* 0.51 0.77 1.07 4.57
OS-5* OS-5* 0.27 0.77 0.59 4.88
OS-6* OS-6* 0.47 0.78 0.96 2.50
OS-7* OS-7* 0.09 0.79 0.21 4.53
OS-8* OS-8* 0.68 0.81 1.37 0.83
OS-9* OS-9* 0.44 0.77 0.94 6.80
OS-10 OS-10 2.17 0.25 0.57 2.19
OS-11 OS-11 2.12 0.25 N/A N/A
OS-12 OS-12 41.62 0.25 5.81 2.27
OS-13 OS-13 7.34 0.25 N/A N/A
30ft Wide Road
Gutter Geome[rv:
Mawmum Alloveable�Vldth for Spread Behlnd Curb Ts,,ck= 25.0 k
Side Slope Behind Curb(leave blankfor no conveyance credit behind curb) Sgpp�= 0.020 k/k
Manning's Roughness Behind Curb(rypically between 0.012 and 0.020) neA�= 0.020
Height of Curb at Gutter Flow Line H��= 6.00 inches
Distance from Curb Face to Street Crown T�o�= 15.0 ft
Gutter Width W= 1.17 k
Street Trans�erse Slope Sx= 0.020 k/ft
Gutter Cross Slope(typically 2 inches over 24 inches or 0.083 ft/ft) S��;= 0.083 ft/ft
Street longitudinal Slope-Enter 0 for sump condition So= 0.005 k/k
Manning's Roughness for Street Section(rypically beNaeen 0.012 and 0.020) nsrReer= 0.016
Minor Storm Major Storm
Max.Allowable Spread for Minor&Major Storm TMax= 15.0 15.0 ft
Max.Alloveable Depth at Gutter Flovrline for Minor&Major Storm dMA%= 6.O 12.0 Inches
Allow Flova Depth at Street Crov+n(check box for yes,leave biank for no) , �
MINOR STORM Allowable Capaaty is based on Spread Cnterwn Minor Storm Major Storm
MAl(�D CTl1DM eu..,.,.tiio r�����w,c�ti��o.t,...no..�ti r.�m.�..� n.. - c� c�a .�fo
36ft Wide Road
Gutter Geome[rv:
Mawmum Allovaable Width for Spread Behind Curb TSACK= 25.0 ft
Side Slope Behind Curb(leave blank for na conveyance credit behind curb) SeAp�= 0.020 R/ft
Manning's Roughness Behind Curb(typically beN�een 0.012 and 0.020) n¢Ap�= 0.020
Height of Curb at Gutter Flow Line H��= 6.00 inches
Distance from Curb Face to Street Crown T�ovm= 18.0 ft
Gutter Width W= 1.17 k
Street Trans�erse Slope Sx= 0.020 fx/k
Gutter Cross Slope(typfcally 2 inches over 24 inches or 0.083 ft/ft) Svr= 0.083 R/R
Street Longitudfnal Slope-Enter 0 for sump condition So= 0.005 ft/ft
Manning's Roughness for Street Sedion(typically beNaeen 0.012 and 0.020) ns-REE-= 0.016
Minor Storm Major Storm
Max Allovaable Spread for Minor&Major Storm Th��z= 18.0 18.0 k
Max.Allovaable Depth at Gutter Flov✓line for Minor&Major Storm d�.,Ax= 6.0 12.0 inches
Allovr Fiov✓Depth at Street Crown(check box for yes,leave blank for no) r �
I f•1ItlOR�TOnh'.�.I;a:rable Capac�N i�Lase�on�precd C��±er:cr. Minor Storm Ma or Storm
A1A.lOR STORM r;llov.able CaoaaN is based on Deoth Cntenon O�u.....= 8.4 89.8 efs
100-yr 2-yr Min Slope 100-yr 2-yr
Sternwheeler Court Basin-02 28.77 4.35 30 ft 0.50% 81.4 5.2
Basin-03 26.91 4.26 30 ft 0.50% 81.4 5.2
Basin-07 19 3.19 30 ft 0.50% 81.4 5.2
Grassland Road St-320a 32.19 2.75 36 ft 0.50% 89.8 8.4
St-321a 26.92 2.43 36 ft 0.50% 89.8 8.4
St-320c 22.43 2.84 37 ft 0.50% 89.8 8.4
St-321b 22.12 3.12 38 ft 0.50% 89.8 8.4
St-204f 46.46 5.68 39 ft 0.50% 89.8 8.4
Nature Parkway Basin-06 21.18 3.46 30 ft 0.50% 81.4 5.2
St-205d 15.21 2.49 31 ft 0.50% 81.4 5.2
St-205e 9.76 1.76 32 ft 0.50% 81.4 5.2
Meadowlark Road St-207c 0 0 36 ft 0.50% 89.8 8.4
St-207b 12.26 1.16 36 ft 0.50% 89.8 8.4
St-208a 12.5 1.77 36 ft 0.50% 89.8 8.4
Basin-14 33.96 6.41 36 ft 0.50% 89.8 8.4
St-203d 16.76 2.36 36 ft 0.50% 89.8 8.4
St-203c 40.61 6.05 36 ft 0.50% 89.8 8.4
P-201a 5.52 0.79 36 ft 0.50% 89.8 8.4
St-203h 29.71 3.73 36 ft 0.50% 89.8 8.4
St-202m 2.91 0.62 36 ft 0.50% 89.8 8.4
St-202l 4.65 0.74 36 ft 0.50% 89.8 8.4
St-212b 6.46 1.22 36 ft 0.50% 89.8 8.4
St-212a 5.56 0.98 36 ft 0.50% 89.8 8.4
Parkland Road St-203e 17.85 3.28 36 ft 0.50% 89.8 8.4
Pathway Road St-203b 20.79 3.58 36 ft 0.50% 89.8 8.4
Walking Stick Way St-203h 29.71 3.73 36 ft 0.50% 89.8 8.4
Morning Star Drive St-202g 66.67 7.74 36 ft 0.50% 89.8 8.4
St-202k 10.38 1.4 36 ft 0.50% 89.8 8.4
Sternwheeler Drive St-202i 40.28 8.4 36 ft 0.50% 89.8 8.4
St-1310a 2.85 0.51 36 ft 0.50% 89.8 8.4
Fairwater Drive St-135a 1.76 0.32 36 ft 0.50% 89.8 8.4
St-136a 10.98 2.42 36 ft 0.50% 89.8 8.4
Trailway Road St-133f 18.79 3.52 36 ft 0.50% 89.8 8.4
Stardust Way St-133e 9.21 1.68 36 ft 0.50% 89.8 8.4
St-133g 11.01 1.98 36 ft 0.50% 89.8 8.4
Wellness Road St-131f 29.55 4.68 36 ft 0.50% 89.8 8.4
St-131b 29.86 4.62 36 ft 0.50% 89.8 8.4
Clipper Way St-121a 2.96 0.43 36 ft 0.50% 89.8 8.4
Greenspace Way St-122b 33.87 5.3 30 ft 0.50% 89.8 8.4
Field View Road St-112a 23.78 2.94 30 ft 0.50% 89.8 8.4
High Meadow Road St-126 13.56 1.82 36 ft 0.50% 89.8 8.4
Street Capacity
Max Design Flow Half Street CapacityStreet Basin or Link
Street
Width
32
APPENDIX C
33
SWMM EXHIBIT AND PC SWMM/
EPA SWMM MODEL
Subcatchment Runoff Summary
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-01 3.67 0.00 0.00 1.41 0.00
Basin-02 3.67 0.00 0.00 0.98 1.22
Basin-03 3.67 0.00 0.00 0.90 1.39
Basin-04 3.67 0.00 0.00 0.68 1.92
Basin-05 3.67 0.00 0.00 0.97 1.05
Basin-06 3.67 0.00 0.00 0.72 1.74
Basin-07 3.67 0.00 0.00 0.78 1.65
Basin-08 3.67 0.00 0.00 0.56 2.11
basin-09 3.67 0.00 0.00 0.86 1.54
Basin-10 3.67 0.00 0.00 0.97 1.20
Basin-11 3.67 0.00 0.00 0.83 1.57
Basin-12 3.67 0.00 0.00 0.43 2.46
Basin-13 3.67 0.00 0.00 1.08 1.18
Basin-14 3.67 0.00 0.00 0.59 2.09
Basin-15 3.67 0.00 0.00 0.94 1.22
Basin-16 3.67 0.00 0.00 0.47 2.39
Basin-17 3.67 0.00 0.00 0.65 1.95
Basin-18 3.67 0.00 0.00 0.59 2.06
Basin-18A 3.67 0.00 0.00 0.30 2.81
Basin-19 3.67 0.00 0.00 0.52 2.35
Basin-20 3.67 0.00 0.00 0.28 2.89
Basin-21 3.67 0.00 0.00 0.73 1.81
Basin-22 3.67 0.00 0.00 0.67 1.99
Basin-22A 3.67 0.00 0.00 0.53 2.27
Sonders East -100yr
SWMM 5.1 Page 1
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-23 3.67 0.00 0.00 0.70 1.82
Basin-24 3.67 0.00 0.00 0.30 2.82
Basin-25 3.67 0.00 0.00 0.46 2.39
Basin-26 3.67 0.00 0.00 0.83 1.55
Basin-27 3.67 0.00 0.00 0.52 2.21
Basin-28 3.67 0.00 0.00 0.77 1.63
Basin-29 3.67 0.00 0.00 0.54 2.29
Basin-30 3.67 0.00 0.00 0.23 3.00
Basin-31 3.67 0.00 0.00 0.66 2.01
Basin-32 3.67 0.00 0.00 0.58 2.07
Basin-33 3.67 0.00 0.00 0.45 2.42
Basin-34 3.67 0.00 0.00 0.64 1.92
Basin-35 3.67 0.00 0.00 0.58 2.10
Basin-36 3.67 0.00 0.00 0.52 2.24
Basin-37 3.67 0.00 0.00 0.74 1.74
Basin-38 3.67 0.00 0.00 0.98 1.31
Basin-39 3.67 0.00 0.00 0.97 1.04
Basin-40 3.67 0.00 0.00 0.61 2.01
Basin-41 3.67 0.00 0.00 0.65 1.95
Basin-42 3.67 0.00 0.00 0.89 1.40
Basin-43 3.67 0.00 0.00 0.73 1.79
Basin-44 3.67 0.00 0.00 0.77 1.64
Basin-45 3.67 0.00 0.00 1.38 0.49
Basin-46 3.67 0.00 0.00 0.59 2.03
Basin-47 3.67 0.00 0.00 0.80 1.62
Sonders East -100yr
SWMM 5.1 Page 2
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-48 3.67 0.00 0.00 0.52 2.29
Basin-49 3.67 0.00 0.00 1.07 0.81
Basin-50 3.67 0.00 0.00 1.24 0.51
Basin-51 3.67 0.00 0.00 0.51 2.27
Basin-OS-01 3.67 0.00 0.00 0.66 1.93
Basin-OS-02 3.67 0.00 0.00 0.32 2.74
Basin-OS-03 3.67 0.00 0.00 0.32 2.82
Basin-OS-04 3.67 0.00 0.00 0.33 2.74
Basin-OS-05 3.67 0.00 0.00 0.32 2.75
Basin-OS-06 3.67 0.00 0.00 0.32 2.77
Basin-OS-07 3.67 0.00 0.00 0.29 2.83
Basin-OS-08 3.67 0.00 0.00 0.25 2.93
Basin-OS-09 3.67 0.00 0.00 0.33 2.74
Basin-OS-10&11 3.67 0.00 0.00 1.37 0.00
LIND-1 3.67 0.00 0.00 1.13 1.94
OS-12 3.67 0.00 0.00 1.97 0.00
OS-13 3.67 0.00 0.00 1.88 0.00
Sonders East -100yr
SWMM 5.1 Page 3
Subcatchment Runoff Summary
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-01 2.29 2.29 0.04 3.83 0.623
Basin-02 1.46 2.68 0.33 28.77 0.731
Basin-03 1.37 2.76 0.29 26.91 0.753
Basin-04 1.05 2.97 0.21 20.34 0.809
Basin-05 1.66 2.71 0.18 21.95 0.738
Basin-06 1.20 2.93 0.20 21.18 0.800
Basin-07 1.23 2.88 0.19 19.00 0.785
Basin-08 0.98 3.09 0.05 5.15 0.842
basin-09 1.26 2.80 0.18 16.19 0.763
Basin-10 1.49 2.69 0.21 19.29 0.734
Basin-11 1.26 2.83 0.18 17.02 0.772
Basin-12 0.75 3.22 0.11 11.80 0.876
Basin-13 1.40 2.58 0.41 30.20 0.703
Basin-14 0.97 3.06 0.33 33.96 0.834
Basin-15 1.51 2.73 0.06 6.29 0.743
Basin-16 0.78 3.18 0.21 21.54 0.865
Basin-17 1.05 3.00 0.22 22.03 0.817
Basin-18 1.00 3.06 0.07 8.09 0.834
Basin-18A 0.53 3.34 0.03 3.45 0.910
Basin-19 0.77 3.12 0.99 89.77 0.850
Basin-20 0.47 3.36 0.40 41.12 0.916
Basin-21 1.12 2.93 0.33 31.70 0.798
Basin-22 1.00 2.98 0.40 36.61 0.813
Basin-22A 0.85 3.12 0.04 4.41 0.849
Sonders East -100yr
SWMM 5.1 Page 4
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-23 1.14 2.96 0.16 16.64 0.806
Basin-24 0.51 3.34 0.11 11.55 0.910
Basin-25 0.80 3.19 0.02 1.93 0.869
Basin-26 1.28 2.83 0.20 18.28 0.771
Basin-27 0.92 3.13 0.03 3.09 0.852
Basin-28 1.26 2.89 0.11 11.72 0.789
Basin-29 0.82 3.11 0.43 40.84 0.847
Basin-30 0.40 3.40 0.10 10.31 0.928
Basin-31 0.98 2.99 0.22 19.99 0.816
Basin-32 1.00 3.07 0.05 5.60 0.837
Basin-33 0.77 3.20 0.06 7.02 0.872
Basin-34 1.09 3.01 0.09 9.45 0.821
Basin-35 0.97 3.07 0.09 9.47 0.837
Basin-36 0.89 3.13 0.11 12.21 0.852
Basin-37 1.17 2.91 0.23 23.14 0.794
Basin-38 1.37 2.68 0.20 16.33 0.731
Basin-39 1.67 2.71 0.35 42.30 0.740
Basin-40 1.04 3.05 0.08 9.37 0.831
Basin-41 1.05 3.00 0.19 19.21 0.818
Basin-42 1.37 2.77 0.16 14.73 0.754
Basin-43 1.14 2.93 0.04 4.06 0.797
Basin-44 1.24 2.89 0.35 35.30 0.786
Basin-45 1.80 2.29 0.11 6.75 0.624
Basin-46 1.03 3.06 0.16 18.53 0.834
Basin-47 1.23 2.86 0.36 34.33 0.779
Sonders East -100yr
SWMM 5.1 Page 5
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-48 0.84 3.13 0.13 13.16 0.852
Basin-49 1.81 2.62 0.13 15.27 0.713
Basin-50 1.93 2.44 0.05 4.35 0.665
Basin-51 0.87 3.14 0.04 4.15 0.856
Basin-OS-01 1.07 3.00 0.05 4.93 0.817
Basin-OS-02 0.58 3.32 0.03 3.38 0.905
Basin-OS-03 0.49 3.32 0.04 3.95 0.904
Basin-OS-04 0.57 3.31 0.05 4.96 0.902
Basin-OS-05 0.57 3.31 0.02 2.63 0.903
Basin-OS-06 0.55 3.32 0.04 4.58 0.905
Basin-OS-07 0.51 3.34 0.01 0.88 0.911
Basin-OS-08 0.45 3.38 0.06 6.70 0.920
Basin-OS-09 0.57 3.31 0.04 4.28 0.902
Basin-OS-10&11 2.34 2.34 0.27 35.17 0.638
LIND-1 0.56 2.50 3.02 138.68 0.682
OS-12 1.70 1.70 1.92 60.09 0.464
OS-13 1.79 1.79 0.36 12.41 0.489
Sonders East -100yr
SWMM 5.1 Page 6
Link Flow Summary
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
B-15 CHANNEL 6.16 0 00:40 1.60
B-19 CONDUIT 87.85 0 00:40 3.25
B-OS-12 CONDUIT 57.71 0 00:55 3.57
LIND1 CONDUIT 0.00 0 00:00 0.00
P-111 CONDUIT 37.36 0 00:43 7.61
P-121 CONDUIT 53.08 0 00:41 8.23
P-122 CONDUIT 50.25 0 00:41 17.36
P-122a CONDUIT 33.84 0 00:40 11.40
P-123 CONDUIT 19.51 0 00:43 6.70
P-124 CONDUIT 13.53 0 00:42 6.25
P-125 CONDUIT 13.56 0 00:42 7.65
P-131 CONDUIT 164.76 0 00:42 18.46
P-1310 CONDUIT 24.60 0 00:40 11.25
P-1311 CONDUIT 21.76 0 00:40 9.67
P-131a CONDUIT 29.82 0 00:42 6.08
P-131e CONDUIT 29.50 0 00:41 6.01
P-132 CONDUIT 108.83 0 00:42 12.23
P-133 CONDUIT 109.08 0 00:42 13.56
P-133a CONDUIT 34.14 0 00:42 9.02
P-133b CONDUIT 11.00 0 00:41 5.56
P-133c CONDUIT 23.89 0 00:42 9.17
P-134 CONDUIT 75.50 0 00:41 10.71
P-135 CONDUIT 43.68 0 00:42 6.90
P-136 CONDUIT 44.00 0 00:41 12.95
Sonders East -100yr
SWMM 5.1 Page 1
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
P-137 CONDUIT 34.21 0 00:41 16.35
P-138 CONDUIT 34.28 0 00:41 3.85
P-139 CONDUIT 24.23 0 00:41 2.16
P-201 CONDUIT 198.18 0 00:45 16.16
P-201a CHANNEL 5.52 0 00:43 0.94
P-202 CONDUIT 192.86 0 00:45 11.24
P-202a CONDUIT 65.32 0 00:48 5.79
P-202c CONDUIT 2.91 0 00:41 6.43
P-202d CONDUIT 63.27 0 00:48 6.71
P-202e CONDUIT 54.55 0 00:51 7.72
P-202f CONDUIT 10.37 0 00:44 3.30
P-203 CONDUIT 35.27 0 00:56 23.43
P-204 CONDUIT 96.26 0 00:44 8.39
P-204a CONDUIT 49.29 0 00:44 7.98
P-204b CONDUIT 45.20 0 00:45 8.62
P-204c CONDUIT 6.11 0 00:40 3.46
P-204d CONDUIT 4.20 0 00:41 1.73
P-204e CONDUIT 42.04 0 00:46 9.12
P-204g CHANNEL 4.20 0 00:41 1.40
P-205 CONDUIT 47.73 0 00:43 5.72
P-205a CONDUIT 24.96 0 00:41 4.61
P-205b CONDUIT 15.20 0 00:41 7.35
P-205c CONDUIT 9.76 0 00:41 3.51
P-206 CONDUIT 24.39 0 00:44 6.43
P-207 CONDUIT 12.26 0 00:45 7.51
Sonders East -100yr
SWMM 5.1 Page 2
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
P-208 CONDUIT 12.50 0 00:43 8.86
P-211 CONDUIT 11.91 0 00:40 9.62
P-212 CONDUIT 5.48 0 00:40 3.10
P-320 CONDUIT 29.24 0 00:38 9.34
P-321 CONDUIT 54.91 0 01:55 17.48
S-100 CONDUIT 35.65 0 00:46 4.49
S-101 CONDUIT 35.80 0 00:45 2.60
S-102 CONDUIT 33.79 0 00:42 2.22
S-110 CONDUIT 37.31 0 00:43 1.10
S-120 CONDUIT 52.96 0 00:42 1.55
S-130 CONDUIT 164.76 0 00:42 8.91
S-1312 CONDUIT 21.76 0 00:40 4.51
S-1313 CONDUIT 4.20 0 00:40 1.43
S-140 CONDUIT 13.07 0 00:42 3.44
S-150 CONDUIT 15.56 0 00:43 0.66
S-151 CONDUIT 9.33 0 00:41 2.69
S-152 CONDUIT 10.10 0 00:40 3.45
S-200 CONDUIT 198.14 0 00:45 4.82
S-210 CONDUIT 10.55 0 00:42 0.48
S-301 CONDUIT 34.22 0 00:45 1.43
S-302 CONDUIT 35.21 0 00:43 2.65
S-302a CONDUIT 3.28 0 00:40 1.48
S-303 CONDUIT 0.00 0 00:00 0.00
S-310 CONDUIT 20.94 0 00:40 1.58
St-111a CHANNEL 3.69 0 00:41 1.13
Sonders East -100yr
SWMM 5.1 Page 3
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
St-112 CONDUIT 34.34 0 00:44 7.00
St-112a CHANNEL 23.78 0 00:43 2.32
St-112b CHANNEL 11.74 0 00:41 1.98
St-121a CHANNEL 2.96 0 00:43 1.00
St-122b CHANNEL 33.87 0 00:40 2.81
St-123a CONDUIT 6.58 0 00:40 4.26
St-126 CHANNEL 13.56 0 00:42 1.69
St-1310a CHANNEL 2.85 0 00:40 1.21
St-131b CHANNEL 29.86 0 00:42 2.78
St-131c CHANNEL 17.96 0 00:40 1.85
St-131d CHANNEL 14.68 0 00:41 1.59
St-131f CHANNEL 29.55 0 00:41 2.81
St-131g CHANNEL 8.76 0 00:40 0.79
St-131h CHANNEL 22.33 0 00:40 2.30
St-133d CHANNEL 23.89 0 00:42 1.63
St-133e CHANNEL 9.21 0 00:40 1.72
St-133f CHANNEL 18.79 0 00:40 1.35
St-133g CHANNEL 11.01 0 00:40 1.98
St-134a CONDUIT 40.48 0 00:40 8.38
St-135a CHANNEL 1.76 0 00:40 1.41
St-136a CHANNEL 10.98 0 00:40 2.17
St-141 CHANNEL 14.18 0 00:40 2.07
St-150a CONDUIT 9.23 0 00:40 2.95
St-202g CHANNEL 66.67 0 00:45 2.70
St-202h CHANNEL 35.92 0 00:43 1.63
Sonders East -100yr
SWMM 5.1 Page 4
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
St-202i CHANNEL 40.28 0 00:40 2.14
St-202j CHANNEL 5.41 0 00:41 1.32
St-202k CHANNEL 10.38 0 00:44 1.30
St-202l CHANNEL 4.65 0 00:41 1.51
St-202m CHANNEL 2.91 0 00:41 0.82
St-203a CHANNEL 35.12 0 00:37 2.15
St-203b CHANNEL 20.79 0 00:40 1.13
St-203c CHANNEL 40.61 0 00:42 1.61
St-203d CHANNEL 16.76 0 00:44 0.81
St-203e CHANNEL 17.85 0 00:41 1.17
St-203f CHANNEL 0.50 0 00:43 0.17
St-203h CHANNEL 29.71 0 00:40 1.76
St-204f CHANNEL 46.46 0 00:41 2.66
St-204g CHANNEL 3.55 0 00:42 0.40
St-204h CHANNEL 18.16 0 00:43 1.37
St-204i CHANNEL 18.87 0 00:42 1.71
St-204j CHANNEL 2.03 0 00:42 0.33
St-205d CHANNEL 15.21 0 00:41 1.99
St-205e CHANNEL 9.76 0 00:41 1.72
St-207b CHANNEL 12.26 0 00:45 1.64
St-207c CHANNEL 0.00 0 00:00 0.00
St-207d CHANNEL 4.30 0 00:42 1.04
St-208a CHANNEL 12.50 0 00:43 1.74
St-212a CONDUIT 5.56 0 00:40 5.95
St-212b CHANNEL 6.46 0 00:40 1.38
Sonders East -100yr
SWMM 5.1 Page 5
Maximum Day of Hour of Maximum
|Flow| Maximum Maximum |Velocity|
Link Type CFS Flow Flow ft/sec
St-320a CHANNEL 32.02 0 00:41 1.76
St-320b CHANNEL 6.68 0 00:43 0.68
St-320c CHANNEL 22.23 0 00:39 1.82
St-321a CHANNEL 26.35 0 00:39 1.64
St-321b CHANNEL 22.04 0 00:38 1.68
C131 ORIFICE 2.26 0 02:39
C132 ORIFICE 9.15 0 02:07
Pond200-Orifice ORIFICE 20.16 0 02:17
Sonders East -100yr
SWMM 5.1 Page 6
Link Flow Summary
Max / Max /
Full Full
Link Flow Depth
B-15 0.01 0.15
B-19 0.04 0.55
B-OS-12 0.05 0.22
LIND1 0.00 0.00
P-111 0.65 1.00
P-121 0.27 0.86
P-122 0.61 0.76
P-122a 0.63 0.92
P-123 0.65 0.62
P-124 0.23 0.46
P-125 0.25 0.39
P-131 1.15 0.70
P-1310 0.53 0.46
P-1311 0.84 0.67
P-131a 0.19 1.00
P-131e 0.36 1.00
P-132 0.76 0.90
P-133 1.03 0.81
P-133a 0.37 0.72
P-133b 0.22 0.63
P-133c 0.44 0.78
P-134 1.47 1.00
P-135 0.51 0.91
P-136 0.34 0.70
Sonders East -100yr
SWMM 5.1 Page 7
Max / Max /
Full Full
Link Flow Depth
P-137 0.11 0.40
P-138 0.04 0.20
P-139 0.03 0.23
P-201 1.25 0.60
P-201a 0.01 0.17
P-202 0.75 0.82
P-202a 0.78 0.91
P-202c 0.12 0.62
P-202d 0.91 0.97
P-202e 0.43 1.00
P-202f 0.35 1.00
P-203 0.65 1.00
P-204 0.67 0.86
P-204a 0.66 0.86
P-204b 0.62 0.71
P-204c 0.34 1.00
P-204d 0.14 0.86
P-204e 0.43 0.89
P-204g 0.00 0.13
P-205 0.56 0.64
P-205a 0.38 0.56
P-205b 0.15 0.69
P-205c 0.48 0.83
P-206 0.26 0.55
P-207 0.90 0.87
Sonders East -100yr
SWMM 5.1 Page 8
Max / Max /
Full Full
Link Flow Depth
P-208 0.48 0.74
P-211 0.82 0.67
P-212 0.44 1.00
P-320 1.25 1.00
P-321 2.06 1.00
S-100 0.02 0.18
S-101 0.07 0.27
S-102 0.05 0.30
S-110 0.01 0.47
S-120 0.02 0.47
S-130 0.08 0.32
S-1312 0.01 0.13
S-1313 0.00 0.09
S-140 0.01 0.11
S-150 0.00 0.26
S-151 0.01 0.10
S-152 0.00 0.09
S-200 0.10 0.63
S-210 0.01 0.52
S-301 0.03 0.52
S-302 0.06 0.26
S-302a 0.00 0.19
S-303 0.00 0.17
S-310 0.01 0.51
St-111a 0.00 0.14
Sonders East -100yr
SWMM 5.1 Page 9
Max / Max /
Full Full
Link Flow Depth
St-112 0.67 1.00
St-112a 0.02 0.22
St-112b 0.01 0.18
St-121a 0.00 0.13
St-122b 0.03 0.24
St-123a 0.00 0.05
St-126 0.02 0.20
St-1310a 0.00 0.12
St-131b 0.02 0.23
St-131c 0.02 0.22
St-131d 0.01 0.22
St-131f 0.02 0.23
St-131g 0.03 0.23
St-131h 0.02 0.22
St-133d 0.05 0.27
St-133e 0.01 0.24
St-133f 0.02 0.27
St-133g 0.01 0.17
St-134a 0.01 0.13
St-135a 0.00 0.09
St-136a 0.01 0.16
St-141 0.01 0.19
St-150a 0.01 0.09
St-202g 0.09 0.37
St-202h 0.06 0.34
Sonders East -100yr
SWMM 5.1 Page 10
Max / Max /
Full Full
Link Flow Depth
St-202i 0.06 0.31
St-202j 0.00 0.22
St-202k 0.02 0.20
St-202l 0.00 0.25
St-202m 0.01 0.14
St-203a 0.06 0.80
St-203b 0.03 0.47
St-203c 0.06 0.57
St-203d 0.12 0.37
St-203e 0.02 0.28
St-203f 0.00 0.14
St-203h 0.05 0.53
St-204f 0.05 0.37
St-204g 0.00 0.21
St-204h 0.02 0.26
St-204i 0.03 0.23
St-204j 0.00 0.18
St-205d 0.02 0.20
St-205e 0.01 0.17
St-207b 0.02 0.19
St-207c 0.00 0.11
St-207d 0.01 0.15
St-208a 0.01 0.19
St-212a 0.54 0.52
St-212b 0.01 0.16
Sonders East -100yr
SWMM 5.1 Page 11
Max / Max /
Full Full
Link Flow Depth
St-320a 0.05 0.50
St-320b 0.01 0.22
St-320c 0.03 0.46
St-321a 0.04 0.50
St-321b 0.03 0.57
C131 1.00
C132 1.00
Pond200-Orifice 1.00
Sonders East -100yr
SWMM 5.1 Page 12
Node Inflow Summary
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
B--05 JUNCTION 21.95 21.95 0 00:40
B-15 JUNCTION 6.29 6.29 0 00:40
B-19 JUNCTION 89.77 89.77 0 00:40
B-OS-12 JUNCTION 60.09 60.09 0 00:50
J123 JUNCTION 21.18 21.18 0 00:40
J81 JUNCTION 0.00 29.86 0 00:42
J92 JUNCTION 0.00 33.87 0 00:40
J97 JUNCTION 35.30 35.30 0 00:40
LIND1 JUNCTION 0.00 0.00 0 00:00
P-111 JUNCTION 0.00 37.37 0 00:43
P-121 JUNCTION 0.00 53.09 0 00:41
P-122 JUNCTION 0.00 50.50 0 00:41
P-123 JUNCTION 0.00 19.81 0 00:42
P-124 JUNCTION 0.00 13.56 0 00:42
P-125 JUNCTION 0.00 13.56 0 00:42
P-131 JUNCTION 0.00 167.00 0 00:42
P-1310 JUNCTION 0.00 24.60 0 00:40
P-1311 JUNCTION 0.00 21.76 0 00:40
P-131e JUNCTION 0.00 29.55 0 00:41
P-132 JUNCTION 0.00 109.08 0 00:42
P-133 JUNCTION 0.00 109.49 0 00:41
P-133a JUNCTION 0.00 34.14 0 00:42
P-133b JUNCTION 0.00 11.01 0 00:40
P-133c JUNCTION 0.00 23.89 0 00:42
Sonders East -100yr
SWMM 5.1 Page 1
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
P-134 JUNCTION 0.00 79.20 0 00:40
P-135 JUNCTION 0.00 45.72 0 00:41
P-136 JUNCTION 0.00 44.43 0 00:41
P-137 JUNCTION 0.00 34.28 0 00:41
P-138 JUNCTION 11.72 34.97 0 00:40
P-139 JUNCTION 0.00 24.60 0 00:40
P-200 JUNCTION 0.00 198.18 0 00:45
P-201 JUNCTION 0.00 198.04 0 00:45
P-201a JUNCTION 8.09 8.09 0 00:40
P-202 JUNCTION 0.00 192.76 0 00:45
P-202b JUNCTION 0.00 64.75 0 00:48
P-202c JUNCTION 0.00 2.91 0 00:41
P-202d JUNCTION 0.00 63.26 0 00:48
P-202e JUNCTION 0.00 69.24 0 00:45
P-202f JUNCTION 0.00 10.38 0 00:44
P-203 JUNCTION 0.00 62.26 0 00:37
P-204 JUNCTION 0.00 96.76 0 00:43
P-204a JUNCTION 0.00 49.33 0 00:44
P-204b JUNCTION 0.00 45.19 0 00:45
P-204c JUNCTION 0.00 6.16 0 00:40
P-204d JUNCTION 0.00 4.20 0 00:41
P-204e JUNCTION 0.00 46.46 0 00:41
P-204g JUNCTION 5.15 5.15 0 00:40
P-205 JUNCTION 0.00 48.12 0 00:42
P-205a JUNCTION 0.00 24.96 0 00:41
Sonders East -100yr
SWMM 5.1 Page 2
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
P-205b JUNCTION 0.00 15.21 0 00:41
P-205c JUNCTION 0.00 9.76 0 00:41
P-206 JUNCTION 0.00 24.40 0 00:44
P-207 JUNCTION 0.00 12.26 0 00:45
P-208 JUNCTION 0.00 12.50 0 00:43
P-210 JUNCTION 0.00 11.91 0 00:40
P-211 JUNCTION 0.00 11.89 0 00:40
P-212 JUNCTION 0.00 5.56 0 00:40
P-320 JUNCTION 0.00 64.32 0 00:39
P-321 JUNCTION 0.00 47.17 0 00:39
S-100 JUNCTION 0.00 35.80 0 00:45
S-101 JUNCTION 15.27 46.90 0 00:41
S-102 JUNCTION 42.30 42.30 0 00:40
S-110 JUNCTION 0.00 37.36 0 00:43
S-120 JUNCTION 0.00 53.08 0 00:41
S-130 JUNCTION 0.00 164.76 0 00:42
S-1312 JUNCTION 18.28 22.44 0 00:40
S-1313 JUNCTION 4.28 4.28 0 00:40
S-140 JUNCTION 0.00 14.18 0 00:40
S-150 JUNCTION 0.00 18.24 0 00:40
S-151 JUNCTION 0.00 10.10 0 00:40
S-152 JUNCTION 10.31 10.31 0 00:40
S-301 JUNCTION 4.35 38.87 0 00:43
S-302 JUNCTION 39.00 42.24 0 00:40
S-302a JUNCTION 3.38 3.38 0 00:40
Sonders East -100yr
SWMM 5.1 Page 3
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
S-303 JUNCTION 0.00 0.00 0 00:00
St-111a JUNCTION 4.15 4.15 0 00:40
St-112 JUNCTION 0.00 34.62 0 00:43
St-112a JUNCTION 34.33 34.33 0 00:40
St-112b JUNCTION 13.16 13.16 0 00:40
St-121a JUNCTION 4.06 4.06 0 00:40
St-123a JUNCTION 6.75 6.75 0 00:40
St-126 JUNCTION 18.53 18.53 0 00:40
St-1310a JUNCTION 3.09 3.09 0 00:40
St-131b JUNCTION 0.00 32.48 0 00:40
St-131c JUNCTION 19.21 19.21 0 00:40
St-131d JUNCTION 16.33 16.33 0 00:40
St-131f JUNCTION 0.00 31.02 0 00:40
St-131g JUNCTION 9.37 9.37 0 00:40
St-131h JUNCTION 23.14 23.14 0 00:40
St-133d JUNCTION 0.00 27.90 0 00:40
St-133e JUNCTION 9.47 9.47 0 00:40
St-133f JUNCTION 19.99 19.99 0 00:40
St-133g JUNCTION 12.21 12.21 0 00:40
St-134a JUNCTION 40.84 40.84 0 00:40
St-135a JUNCTION 1.93 1.93 0 00:40
St-136a JUNCTION 11.55 11.55 0 00:40
St-141 JUNCTION 14.73 14.73 0 00:40
St-150a JUNCTION 9.45 9.45 0 00:40
St-202g JUNCTION 36.61 65.08 0 00:41
Sonders East -100yr
SWMM 5.1 Page 4
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
St-202h JUNCTION 0.00 45.56 0 00:40
St-202i JUNCTION 41.12 41.12 0 00:40
St-202j JUNCTION 6.70 6.70 0 00:40
St-202k JUNCTION 16.64 16.64 0 00:40
St-202l JUNCTION 4.41 4.41 0 00:40
St-202m JUNCTION 3.45 3.45 0 00:40
St-203a JUNCTION 0.00 60.44 0 00:41
St-203b JUNCTION 22.03 22.03 0 00:40
St-203c JUNCTION 33.96 41.17 0 00:40
St-203d JUNCTION 0.00 17.85 0 00:41
St-203e JUNCTION 21.54 21.91 0 00:40
St-203f JUNCTION 0.88 0.88 0 00:40
St-203h JUNCTION 31.70 31.70 0 00:40
St-204f JUNCTION 30.20 46.19 0 00:42
St-204g JUNCTION 4.58 4.58 0 00:40
St-204h JUNCTION 0.00 18.87 0 00:42
St-204i JUNCTION 19.00 20.80 0 00:40
St-204j JUNCTION 2.63 2.63 0 00:40
St-205d JUNCTION 17.02 17.02 0 00:40
St-205e JUNCTION 11.80 11.80 0 00:40
St-207b JUNCTION 19.29 19.29 0 00:40
St-207c JUNCTION 0.00 0.00 0 00:00
St-207d JUNCTION 4.96 4.96 0 00:40
St-208a JUNCTION 16.19 16.19 0 00:40
St-212a JUNCTION 5.60 5.60 0 00:40
Sonders East -100yr
SWMM 5.1 Page 5
Maximum Maximum
Lateral Total Day of Hour of
Inflow Inflow Maximum Maximum
Node Type CFS CFS Inflow Inflow
St-212b JUNCTION 7.02 7.02 0 00:40
St-320a JUNCTION 28.77 33.88 0 00:40
St-320b JUNCTION 3.95 7.79 0 00:40
St-321a JUNCTION 26.91 26.91 0 00:40
St-321b JUNCTION 20.34 20.34 0 00:40
J131 OUTFALL 0.00 20.16 0 02:17
OF1 OUTFALL 0.00 57.71 0 00:55
OF2 OUTFALL 0.00 2.26 0 02:39
OF3 OUTFALL 0.00 9.15 0 02:07
OF4 OUTFALL 4.93 4.93 0 00:40
Pond100 STORAGE 0.00 311.41 0 00:42
Pond200 STORAGE 12.41 281.06 0 00:43
POND-300 STORAGE 0.00 75.77 0 00:44
Sonders East -100yr
SWMM 5.1 Page 6
Node Inflow Summary
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
B--05 0.185 0.185 -2.373
B-15 0.0629 0.0629 0.001
B-19 0.989 0.989 -0.907
B-OS-12 1.92 1.92 0.029
J123 0.2 0.2 1.613
J81 0 0.39 0.000
J92 0 0.351 0.000
J97 0.351 0.351 0.001
LIND1 0 0 0.000
P-111 0 0.53 0.277
P-121 0 0.667 -0.004
P-122 0 0.624 -0.022
P-123 0 0.274 0.077
P-124 0 0.164 -0.038
P-125 0 0.164 -0.000
P-131 0 2.06 -0.003
P-1310 0 0.262 -0.004
P-1311 0 0.235 0.003
P-131e 0 0.319 -0.001
P-132 0 1.35 0.002
P-133 0 1.35 -0.002
P-133a 0 0.417 0.000
P-133b 0 0.112 0.001
P-133c 0 0.305 0.000
Sonders East -100yr
SWMM 5.1 Page 7
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
P-134 0 0.931 0.049
P-135 0 0.498 0.009
P-136 0 0.481 -0.001
P-137 0 0.373 0.017
P-138 0.112 0.373 0.009
P-139 0 0.262 -0.026
P-200 0 3.71 -0.196
P-201 0 3.71 0.001
P-201a 0.074 0.074 0.072
P-202 0 3.64 -0.005
P-202b 0 1.09 0.005
P-202c 0 0.0317 0.059
P-202d 0 1.06 0.003
P-202e 0 0.882 -1.554
P-202f 0 0.161 -0.001
P-203 0 1.08 -0.450
P-204 0 1.46 0.010
P-204a 0 0.779 -0.005
P-204b 0 0.716 0.004
P-204c 0 0.0629 -0.006
P-204d 0 0.0453 -0.008
P-204e 0 0.669 -0.237
P-204g 0.0453 0.0453 0.045
P-205 0 0.684 0.012
P-205a 0 0.289 -0.055
Sonders East -100yr
SWMM 5.1 Page 8
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
P-205b 0 0.183 0.000
P-205c 0 0.106 -0.000
P-206 0 0.395 0.005
P-207 0 0.21 0.001
P-208 0 0.185 0.000
P-210 0 0.113 -6.272
P-211 0 0.113 -0.003
P-212 0 0.0501 0.005
P-320 0 1.2 -0.647
P-321 0 0.508 -13.759
S-100 0 0.476 0.084
S-101 0.129 0.481 1.193
S-102 0.346 0.346 -1.652
S-110 0 0.529 2.173
S-120 0 0.667 1.286
S-130 0 2.06 0.001
S-1312 0.195 0.235 0.008
S-1313 0.0395 0.0395 -0.049
S-140 0 0.16 0.159
S-150 0 0.181 -4.513
S-151 0 0.0962 -0.093
S-152 0.0961 0.0961 -0.041
S-301 0.0483 0.39 -4.218
S-302 0.31 0.341 -0.371
S-302a 0.0307 0.0307 -0.516
Sonders East -100yr
SWMM 5.1 Page 9
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
S-303 0 0 0.000
St-111a 0.0375 0.0375 0.020
St-112 0 0.492 -0.200
St-112a 0.363 0.363 0.044
St-112b 0.131 0.131 1.405
St-121a 0.0421 0.0421 0.077
St-123a 0.11 0.11 -0.002
St-126 0.164 0.164 0.042
St-1310a 0.0272 0.0272 0.015
St-131b 0 0.392 0.586
St-131c 0.189 0.189 -0.720
St-131d 0.201 0.201 -0.406
St-131f 0 0.32 0.305
St-131g 0.0836 0.0836 -0.522
St-131h 0.235 0.235 -0.210
St-133d 0 0.307 0.672
St-133e 0.0884 0.0884 -0.633
St-133f 0.217 0.217 -0.630
St-133g 0.112 0.112 0.010
St-134a 0.433 0.433 -0.001
St-135a 0.0173 0.0173 0.034
St-136a 0.108 0.108 0.005
St-141 0.16 0.16 -0.154
St-150a 0.0851 0.0851 -0.100
St-202g 0.398 0.856 2.115
Sonders East -100yr
SWMM 5.1 Page 10
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
St-202h 0 0.463 0.919
St-202i 0.395 0.395 -0.806
St-202j 0.0624 0.0624 -3.021
St-202k 0.161 0.161 0.072
St-202l 0.044 0.044 1.216
St-202m 0.0317 0.0317 0.043
St-203a 0 0.761 0.782
St-203b 0.217 0.217 -1.464
St-203c 0.326 0.54 -0.443
St-203d 0 0.218 1.742
St-203e 0.205 0.213 -1.428
St-203f 0.00816 0.00816 5.728
St-203h 0.332 0.332 1.522
St-204f 0.411 0.672 0.387
St-204g 0.0424 0.0424 -2.710
St-204h 0 0.218 0.503
St-204i 0.192 0.217 -0.452
St-204j 0.0243 0.0243 0.061
St-205d 0.183 0.183 0.009
St-205e 0.106 0.106 0.022
St-207b 0.211 0.211 0.091
St-207c 0 0 0.000
St-207d 0.0458 0.0458 -1.845
St-208a 0.185 0.185 0.031
St-212a 0.0501 0.0501 -0.002
Sonders East -100yr
SWMM 5.1 Page 11
Lateral Total Flow
Inflow Inflow Balance
Volume Volume Error
Node 10^6 gal 10^6 gal %
St-212b 0.0634 0.0634 0.009
St-320a 0.33 0.419 1.759
St-320b 0.0423 0.089 0.957
St-321a 0.293 0.293 2.720
St-321b 0.213 0.213 1.833
J131 0 3.71 0.000
OF1 0 1.92 0.000
OF2 0 0.441 0.000
OF3 0 1.57 0.000
OF4 0.048 0.048 0.000
Pond100 0 4.06 13.720
Pond200 0.357 5.2 6.485
POND-300 0 1.79 9.923
Sonders East -100yr
SWMM 5.1 Page 12
Storage Volume Summary
Average Average Evaporation Exfiltration Maximum
Storage Volume Percent Loss Loss Volume
Unit 1000 ft³ Full % % 1000 ft³
Pond100 361.681 35.9 0.0 0.0 452.268
Pond200 327.004 65.9 0.0 0.0 474.098
POND-300 58.079 51.0 0.0 0.0 102.097
Sonders East -100yr
SWMM 5.1 Page 1
Storage Volume Summary
Maximum Day of Hour of Maximum
Storage Percent Maximum Maximum Outflow
Unit Full Volume Volume CFS
Pond100 44.9 0 02:39 2.26
Pond200 95.6 0 02:17 20.16
POND-300 89.7 0 02:07 9.15
Sonders East -100yr
SWMM 5.1 Page 2
Subcatchment Runoff Summary
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-01 0.98 0.00 0.00 0.95 0.00
Basin-02 0.98 0.00 0.00 0.64 0.31
Basin-03 0.98 0.00 0.00 0.59 0.35
Basin-04 0.98 0.00 0.00 0.45 0.48
Basin-05 0.98 0.00 0.00 0.66 0.27
Basin-06 0.98 0.00 0.00 0.49 0.44
Basin-07 0.98 0.00 0.00 0.52 0.42
Basin-08 0.98 0.00 0.00 0.38 0.53
basin-09 0.98 0.00 0.00 0.55 0.39
Basin-10 0.98 0.00 0.00 0.64 0.30
Basin-11 0.98 0.00 0.00 0.54 0.40
Basin-12 0.98 0.00 0.00 0.29 0.62
Basin-13 0.98 0.00 0.00 0.65 0.30
Basin-14 0.98 0.00 0.00 0.40 0.53
Basin-15 0.98 0.00 0.00 0.63 0.31
Basin-16 0.98 0.00 0.00 0.32 0.60
Basin-17 0.98 0.00 0.00 0.44 0.49
Basin-18 0.98 0.00 0.00 0.40 0.52
Basin-18A 0.98 0.00 0.00 0.20 0.71
Basin-19 0.98 0.00 0.00 0.34 0.59
Basin-20 0.98 0.00 0.00 0.19 0.73
Basin-21 0.98 0.00 0.00 0.48 0.46
Basin-22 0.98 0.00 0.00 0.43 0.50
Basin-22A 0.98 0.00 0.00 0.35 0.57
Sonders East-2yr
SWMM 5.1 Page 1
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-23 0.98 0.00 0.00 0.47 0.46
Basin-24 0.98 0.00 0.00 0.20 0.71
Basin-25 0.98 0.00 0.00 0.31 0.60
Basin-26 0.98 0.00 0.00 0.55 0.39
Basin-27 0.98 0.00 0.00 0.36 0.56
Basin-28 0.98 0.00 0.00 0.52 0.41
Basin-29 0.98 0.00 0.00 0.35 0.58
Basin-30 0.98 0.00 0.00 0.15 0.76
Basin-31 0.98 0.00 0.00 0.43 0.51
Basin-32 0.98 0.00 0.00 0.40 0.53
Basin-33 0.98 0.00 0.00 0.30 0.61
Basin-34 0.98 0.00 0.00 0.44 0.49
Basin-35 0.98 0.00 0.00 0.39 0.53
Basin-36 0.98 0.00 0.00 0.35 0.57
Basin-37 0.98 0.00 0.00 0.49 0.44
Basin-38 0.98 0.00 0.00 0.61 0.33
Basin-39 0.98 0.00 0.00 0.66 0.27
Basin-40 0.98 0.00 0.00 0.41 0.51
Basin-41 0.98 0.00 0.00 0.44 0.49
Basin-42 0.98 0.00 0.00 0.59 0.35
Basin-43 0.98 0.00 0.00 0.48 0.45
Basin-44 0.98 0.00 0.00 0.52 0.42
Basin-45 0.98 0.00 0.00 0.84 0.12
Basin-46 0.98 0.00 0.00 0.41 0.51
Basin-47 0.98 0.00 0.00 0.53 0.41
Sonders East-2yr
SWMM 5.1 Page 2
Total Total Total Total Imperv
Precip Runon Evap Infil Runoff
Subcatchment in in in in in
Basin-48 0.98 0.00 0.00 0.35 0.58
Basin-49 0.98 0.00 0.00 0.73 0.20
Basin-50 0.98 0.00 0.00 0.82 0.13
Basin-51 0.98 0.00 0.00 0.35 0.57
Basin-OS-01 0.98 0.00 0.00 0.44 0.49
Basin-OS-02 0.98 0.00 0.00 0.22 0.69
Basin-OS-03 0.98 0.00 0.00 0.21 0.71
Basin-OS-04 0.98 0.00 0.00 0.22 0.69
Basin-OS-05 0.98 0.00 0.00 0.22 0.69
Basin-OS-06 0.98 0.00 0.00 0.22 0.70
Basin-OS-07 0.98 0.00 0.00 0.20 0.71
Basin-OS-08 0.98 0.00 0.00 0.17 0.74
Basin-OS-09 0.98 0.00 0.00 0.22 0.69
Basin-OS-10&11 0.98 0.00 0.00 0.93 0.00
LIND-1 0.98 0.00 0.00 0.45 0.48
OS-12 0.98 0.00 0.00 0.97 0.00
OS-13 0.98 0.00 0.00 0.97 0.00
Sonders East-2yr
SWMM 5.1 Page 3
Subcatchment Runoff Summary
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-01 0.03 0.03 0.00 0.07 0.033
Basin-02 0.01 0.32 0.04 4.35 0.328
Basin-03 0.01 0.37 0.04 4.26 0.373
Basin-04 0.01 0.50 0.04 3.85 0.506
Basin-05 0.04 0.30 0.02 2.14 0.308
Basin-06 0.02 0.46 0.03 3.46 0.469
Basin-07 0.02 0.43 0.03 3.19 0.442
Basin-08 0.02 0.56 0.01 0.91 0.572
basin-09 0.01 0.40 0.03 2.87 0.409
Basin-10 0.02 0.32 0.03 2.75 0.327
Basin-11 0.01 0.41 0.03 2.91 0.419
Basin-12 0.02 0.64 0.02 2.39 0.659
Basin-13 0.01 0.31 0.05 5.25 0.313
Basin-14 0.01 0.54 0.06 6.41 0.556
Basin-15 0.02 0.33 0.01 0.83 0.335
Basin-16 0.01 0.62 0.04 4.40 0.632
Basin-17 0.01 0.51 0.04 4.04 0.517
Basin-18 0.02 0.54 0.01 1.45 0.552
Basin-18A 0.02 0.73 0.01 0.78 0.742
Basin-19 0.01 0.60 0.19 18.47 0.612
Basin-20 0.01 0.74 0.09 9.31 0.756
Basin-21 0.01 0.47 0.05 5.80 0.479
Basin-22 0.01 0.51 0.07 7.19 0.522
Basin-22A 0.01 0.58 0.01 0.89 0.597
Sonders East-2yr
SWMM 5.1 Page 4
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-23 0.02 0.48 0.03 2.88 0.488
Basin-24 0.01 0.73 0.02 2.61 0.742
Basin-25 0.02 0.63 0.00 0.38 0.639
Basin-26 0.01 0.41 0.03 3.08 0.415
Basin-27 0.03 0.58 0.01 0.57 0.598
Basin-28 0.02 0.43 0.02 1.84 0.441
Basin-29 0.01 0.59 0.08 8.38 0.599
Basin-30 0.01 0.77 0.02 2.48 0.790
Basin-31 0.01 0.52 0.04 3.95 0.528
Basin-32 0.02 0.55 0.01 0.99 0.559
Basin-33 0.02 0.63 0.01 1.41 0.647
Basin-34 0.02 0.51 0.01 1.59 0.520
Basin-35 0.02 0.55 0.02 1.76 0.560
Basin-36 0.02 0.58 0.02 2.34 0.598
Basin-37 0.01 0.45 0.04 4.04 0.464
Basin-38 0.01 0.34 0.03 2.79 0.349
Basin-39 0.04 0.30 0.04 4.02 0.311
Basin-40 0.02 0.53 0.01 1.62 0.543
Basin-41 0.01 0.51 0.03 3.53 0.519
Basin-42 0.01 0.37 0.02 2.35 0.377
Basin-43 0.01 0.47 0.01 0.73 0.475
Basin-44 0.02 0.43 0.05 5.81 0.442
Basin-45 0.01 0.13 0.01 0.69 0.138
Basin-46 0.02 0.54 0.03 3.21 0.551
Basin-47 0.01 0.42 0.05 5.92 0.433
Sonders East-2yr
SWMM 5.1 Page 5
Perv Total Total Peak
Runoff Runoff Runoff Runoff Runoff
Subcatchment in in 10^6 gal CFS Coeff
Basin-48 0.01 0.59 0.02 2.66 0.602
Basin-49 0.04 0.24 0.01 1.20 0.246
Basin-50 0.02 0.15 0.00 0.30 0.154
Basin-51 0.02 0.59 0.01 0.79 0.607
Basin-OS-01 0.02 0.50 0.01 0.89 0.514
Basin-OS-02 0.02 0.71 0.01 0.74 0.727
Basin-OS-03 0.01 0.72 0.01 0.83 0.731
Basin-OS-04 0.01 0.71 0.01 1.10 0.723
Basin-OS-05 0.01 0.71 0.01 0.58 0.725
Basin-OS-06 0.01 0.71 0.01 1.02 0.730
Basin-OS-07 0.01 0.73 0.00 0.20 0.744
Basin-OS-08 0.01 0.75 0.01 1.57 0.770
Basin-OS-09 0.01 0.71 0.01 0.95 0.722
Basin-OS-10&11 0.05 0.05 0.01 0.85 0.051
LIND-1 0.00 0.48 0.58 21.81 0.493
OS-12 0.00 0.00 0.00 0.55 0.004
OS-13 0.01 0.01 0.00 0.12 0.005
Sonders East-2yr
SWMM 5.1 Page 6
34
APPENDIX D
35
WQCV DETENTION POND
DESIGN, RATING CURVES,
AND LID SIZING
Pond
100-yr
WSEl
Volume (ac-
ft)
Flow in
(cfs)
Flow out
(cfs)
100 5018.19 10.38 311 2.26
200 5041.89 10.88 281 20.16
300 5049.78 2.34 76 9.15
Total --- 23.61 668.24 31.57
Pond Summary
Elevation
(ft.)
Depth
(ft.) Area (ft.
2 )
Storage
(ft.3)
Storage
(acre-ft.)
Cumulative Storage
(acre-ft.)
5012.25 0.00 1712 0.00 0.00 0.00
5013.00 0.75 16185 5,790 0.13 0.13
5014.00 1.75 40064 27,238 0.63 0.76
5014.52 2.27 87279 32,546 0.75 1.51
5015.00 2.75 130238 51,473 1.18 2.69
5016.00 3.75 135149 132,686 3.05 5.73
5017.00 4.75 140101 137,617 3.16 8.89
5018.00 5.75 145063 142,574 3.27 12.17
5019.00 6.75 150057 147,553 3.39 15.55
5020.00 7.75 155079 152,561 3.50 19.06
5021.00 8.75 160149 157,607 3.62 22.67
5021.75 9.50 161318 120,550 2.77 25.44
5018.19 ft
Volume = 10.38 ac-ft
Qout= 2.26 cfs
Qin= 311.41 cfs
where:
V = volume between contour interval
d = elevationn - elevationn-1
A = area of elevationn-1 contour
B = area of elevationn contour
Pond 100
100-year WSEL =
Proposed Pond Volume Rating Curve
()V d A B AB= + +
1
3
Elevation
(ft.)
Depth
(ft.) Area (ft.
2 )
Storage
(ft.3)
Storage
(acre-ft.)
Cumulative Storage
(acre-ft.)
5036 0.0 0 0.00 0.00 0.00
5037 1.0 11306 3,769 0.09 0.09
5038 2.0 29437 19,662 0.45 0.54
5039 3.0 63866 45,554 1.05 1.58
5040 4.0 106877 84,454 1.94 3.52
5041 5.0 184901 144,118 3.31 6.83
5042 6.0 199103 191,958 4.41 11.24
5041 0.0 44256 0.00 0.00 0.00
5042 1.0 50949 47,563 1.09 1.09
5041.89 ft
Volume = 10.88 ac-ft
Qout= 20.16 cfs
Qin= 281.06 cfs
where:
V = volume between contour interval
d = elevationn - elevationn-1
A = area of elevationn-1 contour
B = area of elevationn contour
100-year WSEL =
Pond 200
Proposed Pond Volume Rating Curve
Proposed Detention Pond
Proposed Rain Garden
()V d A B AB= + +
1
3
Elevation
(ft.)
Depth
(ft.) Area (ft.
2 )
Storage
(ft.3)
Storage
(acre-ft.)
Cumulative Storage
(acre-ft.)
5044.5 0.0 0 0.00 0.00 0.00
5045 0.5 58 10 0.00 0.00
5046 1.5 3927 1,487 0.03 0.03
5047 2.5 12165 7,668 0.18 0.21
5048 3.5 23175 17,377 0.40 0.61
5049 4.5 47353 34,551 0.79 1.40
5050 5.5 54357 50,815 1.17 2.66
5049 0.0 11959 0.00 0.00 0.00
5050 1.0 14346 13,134 0.30 0.30
5049.78 ft
Volume = 2.34 ac-ft
Qout= 9.15 cfs
Qin= 75.77 cfs
where:
V = volume between contour interval
d = elevationn - elevationn-1
A = area of elevationn-1 contour
B = area of elevationn contour
Pond 300
100-year WSEL =
Proposed Rain Garden
Proposed Detention Pond
Proposed Pond Volume Rating Curve
()V d A B AB= + +
1
3
Project:
Basin ID:
Depth Increment = 1.00 ft
Watershed Information Top of Micropool
Selected BMP Type =EDB Note: L / W Ratio < 1
Watershed Area = 126.27 acres L / W Ratio = 0.18
Watershed Length = 1,000 ft Note: Lc/L Ratio > 0.9
Watershed Length to Centroid = 2,000 ft Lc / L Ratio = 2
Watershed Slope = 0.020 ft/ft
Watershed Imperviousness = 50.00% percent
Percentage Hydrologic Soil Group A = 0.0% percent
Percentage Hydrologic Soil Group B = 0.0% percent
Percentage Hydrologic Soil Groups C/D = 100.0% percent
Target WQCV Drain Time = 40.0 hours
Location for 1-hr Rainfall Depths = User Input
Optional User Overrides
Water Quality Capture Volume (WQCV) = 2.170 acre-feet acre-feet
Excess Urban Runoff Volume (EURV) = 5.973 acre-feet acre-feet
2-yr Runoff Volume (P1 = 0.83 in.) = 3.447 acre-feet inches
5-yr Runoff Volume (P1 = 1.09 in.) = 5.276 acre-feet inches
10-yr Runoff Volume (P1 = 1.33 in.) = 7.421 acre-feet inches
25-yr Runoff Volume (P1 = 1.69 in.) = 11.640 acre-feet inches
50-yr Runoff Volume (P1 = 1.99 in.) = 14.782 acre-feet inches
100-yr Runoff Volume (P1 = 2.31 in.) = 18.606 acre-feet inches
500-yr Runoff Volume (P1 = 3.14 in.) = 27.666 acre-feet inches
Approximate 2-yr Detention Volume = 3.655 acre-feet
Approximate 5-yr Detention Volume = 5.708 acre-feet
Approximate 10-yr Detention Volume = 6.806 acre-feet
Approximate 25-yr Detention Volume = 8.188 acre-feet
Approximate 50-yr Detention Volume = 8.878 acre-feet
Approximate 100-yr Detention Volume = 10.469 acre-feet
Define Zones and Basin Geometry
Select Zone 1 Storage Volume (Required) = acre-feet
Select Zone 2 Storage Volume (Optional) = acre-feet
Select Zone 3 Storage Volume (Optional) = acre-feet
Total Detention Basin Volume = acre-feet
Initial Surcharge Volume (ISV) =ft 3
Initial Surcharge Depth (ISD) = ft
Total Available Detention Depth (Htotal) =ft
Depth of Trickle Channel (HTC) =ft
Slope of Trickle Channel (STC) =ft/ft
Slopes of Main Basin Sides (Smain) =H:V
Basin Length-to-Width Ratio (RL/W) =
Initial Surcharge Area (AISV) =ft 2
Surcharge Volume Length (LISV) =ft
Surcharge Volume Width (WISV) =ft
Depth of Basin Floor (HFLOOR) =ft
Length of Basin Floor (LFLOOR) =ft
Width of Basin Floor (WFLOOR) =ft
Area of Basin Floor (AFLOOR) =ft 2
Volume of Basin Floor (VFLOOR) =ft 3
Depth of Main Basin (HMAIN) =ft
Length of Main Basin (LMAIN) =ft
Width of Main Basin (WMAIN) =ft
Area of Main Basin (AMAIN) =ft 2
Volume of Main Basin (VMAIN) =ft 3
Calculated Total Basin Volume (Vtotal) =acre-feet
After providing required inputs above including 1-hour rainfall
depths, click 'Run CUHP' to generate runoff hydrographs using
the embedded Colorado Urban Hydrograph Procedure.
Volume
(ft 3)
Volume
(ac-ft)
Area
(acre)
DETENTION BASIN STAGE-STORAGE TABLE BUILDER
Optional
Override
Area (ft 2)
Length
(ft)
Optional
Override
Stage (ft)
Stage
(ft)
Stage - Storage
Description
Area
(ft 2)
Width
(ft)
Sonders East
Basins 1-52 at 50% Impervious (excludes east side of Turberry Road)
MHFD-Detention, Version 4.05 (January 2022)
Example Zone Configuration (Retention Pond)
MHFD-Detention_v4-05 (1) (1), Basin 7/18/2024, 7:11 PM
New Single Family Impervious Area (Roof, Pavement and Walks)1,503,649 sf
New Multi Family Impervious Area (Roof, Pavement and Walks)1,161,754 sf
Total New Impervious Area (Roof,Pavement and Walks)2,665,403 sf
Required Minimum Single Family Impervious Area to be treated (50% of impervious area) RG only 751,825 sf
Required Minimum Multi Family Impervious Area to be treated (75% of impervious area) RG only 871,315 sf
Total Required Minimum (Multi plus Single Family) area to be treated 1,623,140 sf
Total Single Family area Treated Impervious Area (Ponds 200 and 300)906,442 sf
Total Muti family area Treated Impervious Area (Ponds 200 and 300)748,181 sf
Total Impervious Area Treated 1,654,623 sf
Percent LID Treatment Provided for Entire Site Area 62%
LID TABLE
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =48.9 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.489
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.16 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area) Area = 2,809,465 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =38,072 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region, VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =12 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =27477 sq ft
D) Actual Flat Surface Area AActual =44256 sq ft
E) Area at Design Depth (Top Surface Area)ATop =50950 sq ft
F) Rain Garden Total Volume VT=47,603 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =cu ft
iii) Orifice Diameter, 3/8" Minimum DO = in
Design Procedure Form: Rain Garden (RG)
J.Gooch
Aspen Engineering
June 11, 2024
Waters Edge East
Pond 200
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
Overall Site-LID_ UD-BMP_v3.07 Pond 200 06-11-2024.xlsm, RG 6/11/2024, 9:23 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
J.Gooch
Aspen Engineering
June 11, 2024
Waters Edge East
Pond 200
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
Overall Site-LID_ UD-BMP_v3.07 Pond 200 06-11-2024.xlsm, RG 6/11/2024, 9:23 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =33.1 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.331
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV = 0.13 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area) Area = 851,178 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =9,125 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region, VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =12 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical) Z = 4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =5635 sq ft
D) Actual Flat Surface Area AActual =11960 sq ft
E) Area at Design Depth (Top Surface Area)ATop =14346 sq ft
F) Rain Garden Total Volume VT=13,153 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =cu ft
iii) Orifice Diameter, 3/8" Minimum DO = in
Design Procedure Form: Rain Garden (RG)
J.Gooch
Aspen Engineering
June 11, 2024
Waters Edge East
Pond 300
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
Overall Site-LID_ UD-BMP_v3.07 Pond 300 06-11-2024.xlsm, RG 6/11/2024, 9:25 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
J.Gooch
Aspen Engineering
June 11, 2024
Waters Edge East
Pond 300
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
Overall Site-LID_ UD-BMP_v3.07 Pond 300 06-11-2024.xlsm, RG 6/11/2024, 9:25 AM
36
APPENDIX E
37
PRELIMINARY NO. 8 DITCH
CALCULATIONS
Flow Slope
Bottom
Width Side Slope
cfs ft/ft ft X:1
A 250cfs Ditch Section Trapezoidal 250 0.001 0.035 14 4
A 1025cfs Ditch Section Trapezoidal 1025 0.001 0.035 14 4
Depth ft 3.65 7.03
4:1 3.6ft Deep (250cfs)Velocity ft/s 2.39 3.46
7ft Deep (1025cfs)Top Width ft 43.22 70.28
Area ft2 104.51 296.43
Hydraulic Radius ft
2.37 4.12
Width =14ft
Slope =0.1%
Solution
Channel Number Description Channel Type Manning's
Roughness
Given
No 8 Irrigation Ditch
38
APPENDIX F
39
HISTORIC DRAINAGE BASIN MAPS,
PROPOSED DRAINAGE BASIN MAP,
EROSION CONTROL PLANS &
EROSION CONTROL NOTES &
DETAILS PLANS
NOTES:
1.PROPOSED ELEVATIONS SHOWN ARE RELATIVE TO A DATUM OF 5000 FEET, AND ARE BASED ON THE
BENCHMARKS DESCRIBED ON SHEET C-001.
2.PLEASE REFER TO THE RATIONAL METHOD CALCULATIONS FOR BASIN FLOW CALCULATIONS.
3.PLEASE REFER TO THE LIND FILING 1 DRAINAGE REPORT, AND THE EXCERPTS FROM THE REPORT,IN
APPENDIX F, FOR EXISTING LIND 1 POND SIZING FOR THE ORGINAL LIND FILINGS 1, 2, AND 3, OF
WHICH SONDERS EAST IS NOW WHAT WAS LIND FILINGS 2 & 3.
4.EXISTING BASIN EX1 FLOWS EAST/SOUTHEAST AND INTO THE NO. 8 DITCH.
5.EXISTING BASIN EX2 FLOWS SOUTHEAST AND INTO EXISTING POND 100. POND 100 HAS A WATER
QUALITY/ DETENTION POND OUTLET STRUCTURE THAT CONVEYS FLOW SOUTH AND EAST AND INTO
THE NO. 8 DITCH.
6.THE LIND FILING ONE DEVELOPMENT FLOWS ARE ALSO CONVEYED DIRECTLY TO POND 100.
EX1
5
OS
-
1
EX1
64.45 0.25
EX2
65.09 0.25
LIND
44.53 0.63
EX2
RI
C
H
A
R
D
S
L
A
K
E
R
O
A
D
NO. 8 DITCH
NO
.
8
D
I
T
C
H
NO
.
8
D
I
T
C
H
TURNBERRY ROAD TURNBERRY ROAD
RI
C
H
A
R
D
S
L
A
K
E
R
O
A
D
AS
P
E
N
0'
SCALE: 1" = 200'
200'400'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
EX
I
S
T
I
N
G
D
R
A
I
N
A
G
E
E
X
H
I
B
I
T
EX-1
1 1
AUGUST 30, 2023
105001
JRG
JRG
JRG
LEGEND
EXISTING CONTOURS
EXISTING DRAINAGE BASIN BOUNDARY LINE
EXISTING STORM PIPE & MANHOLE
EXISTING DRAINAGE BASIN ID
ACRES / 'C' VALUE
PROPOSED DRAINAGE DESIGN POINT
DRAINAGE FLOW DIRECTION
1
44.53 0.63
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2 BUSINESS DAYS IN ADVANCE
CENTER OF COLORADO
CALL UTILITY NOTIFICATION
1-800-922-1987
MEMBER UTILITIES.
EX
POND
100
EXISTING DRAINAGE BASIN SUMMARY TABLE:
AREADESIGN POINTBASIN
(ACRES)VALUE
Q2
(CFS)
'C'
1 � i �� i�j � � q � t. 1 � �_ _ \ � �.\� � �� �\`` \`` . ,, • �
� I , � � �.�� � �� �`�•�rr�� � � �� �� � � � '� � . � i
� � -+�—' �yI �� I l�' I �i � \ ��` � // '� �\������\�\� � �\� � ��`.\�\ �, � �\�� / i �� CLOGGEUINLETOVERFLOWSUMMARY � m
{ ! � ! i'L�i i. � �� � \� � r�_i' '-���+c ,�`. �\��\�` �� �\ ��� $� . � / NUMBEft O P NTOW F ET) � o
o i : �' t / �,� � ��, � ` � i�-_ \ �' ♦ � � �\ � ep. ���. i
��� i 'n:/ . � ! I; � r � /� / ` \ \ ,. / `a ` \\\ ` ` \\ \ \ �.` �.. `� �,�' � / ( .
i & � i • F� � '�I I / � /�, �� � •'` \� '���\ \ ��\ � �� '� 1��\ i / 3 Q 5339.75 , - _
, �� � � ' �, �� f'ir 1 1 ` ,r 1 I �•\�� ` _ _-' ' ' _-' '� .��� �\� ��.\�\,`'� '-'�\�,� \���� // i, 1 Q 5336.SU I � '
i i �i�, �� il ' /^�•^ � .!/ � _ \ � �♦ � `� � � � ♦ � . . ���\ /� i 5 m 5334.58
; ' :-----�-i; ��_ , \ I
� ' i �+ I�� �� 1 � (� 1 � �,�.''C -'� __ '_ r_ ,c � � �\`� � �^ � �\ � �� �\ . ♦`; / 6 � 533M125 - _
'1 , �i � � I I \� . f." � _ "J � �`/ L ♦ � \� ��� ;\ �� � \�k�/ 7 � 532827 � � v�
' i 1 !. � , . 1 I I�� i �� � 1 II �. \�` _ '_" 1_, ���: � \ � . � � . : 1,
yG` � � � . � � 1 z
i ' . �: i ` ��_ ��� ` _' '___ � r � � � � �\� � ; �i� 8 5328.18 . ; � o
�� f / � / t i \ � � � � � � �� i 'U�� in
, r � � I �l � � � _� � ... Jf � '___ - -__- __ �.. `� \\ ` \ M�PRop
I l � � 'v !,_ � �� ` ,. � \ \ � 9 � 5324.84 I
_a_f j;�"i"" I!�" i�T ��/� \ _ .�__-���������` \. :��� ��` 10 � 5324.63 � % Lw�SE inIERTY �
!�. F. � —!_ _ � 'T i � '_-___- -_`__ "" _'�` � �,\ \ `�`� �i. \��\ � 327.50 I � �
��._:�-. - � '' 77 5 J
� � '�—�\��� f�'I! 1 � ir � - -__��- �� ♦ \ if� � \ ��� J2 m 5327.50 e
'� � ' �' � il� !) � L ND OP � ; ,,. � , J , . ---------�`��4`,; ����. �`���\\::� �� I � - - �
, , , • �' F T � F1 IN S �� % � ! � ��/ � ---------�� � ,•� .:'�', .. �� `.,. .. �, ,
L { I 1 I / f /(/ T � \�\ \ \\ �O N Q M1 N - O
s 1 �, ��I �. . � —1 / . 1; �� / /�� � \`�`�.� ��`� `\ \\ ,� I r
� I ,, , , , .- � , ^ - ,�,, .,;\_�` \ ,�. :
. i r � lI � I t % i i ���I ' � � ���- �___�___- `�� �.. `�.�` ��\\ . ♦ � - F��':
' •� � , r � i Y. �% i r� � i l •� '', , -- ;`� \ �. : `,� � �i , � �`�ga� g=Y�S�
a4 ! I :� � � I / � % � �\ � � � ` , I vICINITV MAP !E�R�Y � e
•� / / i � I � � i� / � / � .:�\. ` _ � � � � ��� �� p�j 7YB1�q ?:�.�$�
i -� i r i �� i c._� � , r / , J' ` `` `` .,��'o`'\` `�\ ` � ` �i�� g�iaY���a y�°�^�i
_�-.. ,..- - - - �N�� " - /���� � : � ��� a:�_sn gnY= n
�Fp�� I' � i' ._ �_ _ �_i_, _ � _ _ � . I '/ ' , '� / f—��` \�;�.'��\�\. '��\\ �`;\ � FOR DRAINAGE a��-�a� �. �.s���
e'�'O i .�_�..._y_... oaue i � i i �. `. �. \ t 1 � • ���� `� E d.�3: �1 r"
:a�� .' . "� . • , .�E�-: � ,' � :r. . � . ��ti � , . ;.�\�, ' ` ��. `, REVIEW ONLY � =F8@�7� 5g°sp��
�� � /� / � � , , i / //--�-__ � � � � � I � I NOTFORCONSTRUCTION
:'. .I i i` :��� �� . , ��; � � � �
� i i � ' . 9 \•: . �
, :��g � i � � i �wa a ' I I I /i,. �� �.� � � � � ' ���a\�� �. 1 �� i `� � o iao xoo aoo
h . ,' i � � ' ___` _ _ _ _ ` _ � i' � �� `��� �� � � ���� � � � \l � �
'I � � i ran ruxc / � � / . �. p � �� V� 1 � \\ �
�i � � i ' I i � // �� ��. 1�\��. ` ♦ \ \ i \ �\��,'� �� .
' '� I ; � // 29 � _ ' _ ' ___ _; �w t � •f _-__'__-'' /•• / � ` . ♦ . � � � �`� 1 ` \ i� \ � . � Sca.EwFEEr W r
/�/ � �� \ 1 � � \
� �� /� m on r 31 y° � cs.: i 35 ♦ � �� �.\ � �\\�� �� ♦ � \\� \�� I NOTES : a
,I 30 o.ro �' m ose ' l[� s'CPOSW ♦\ � \\. \ \� � � 1 1 . , \ �IM*EtmoHcvowu�uxw�re��aw�uwan! W w
: i
. 0.�] 0)] � . RO � � .�1 OAf \ \ \ \� \ \� � �`\ \ \ y�{IHlMMIXTEfLHGIBOVMRY:11fWSAflE5) ayJ u
_ - - - - -- � '° � ' LIND PROFERTY ` , ,� • • •, , � • �
y � / B �TE DR � - �i3 ou si •-i ax on 38 \\�\ \� �� �� \��� � :.� �� \♦ I sn�or�.�wn��i��wrsw�i v�.�sv Ma Mro�s�*�w�w R� ?a �w „a
' ~ — - _- _ -- ZB FUT G , � ` . � . � �.u����,a,�E,�,,,,�. .� .� m= =
- � z� ' - ^�- - „ o., URE FILIN �, '. �` . . `, � , o
� . �� . . J < �� o
' 1 ♦ � �� ♦ i oeu�ru�covnwnro q c� 4� �� W o
� ♦ ♦ ��� •. � ♦ ` n¢�wro�ra�d�a.
oa o. _� " ' ' " m an ' __ _ __ _ " ' u a.n / �` i\ .` `.� \ \ \ � -
/�` \ \\ �� �.IwarxwvwR6ExrobEE�scs�muots�o�.
�. + a � y iG R � N r / �i �i� �� i/�X /� \ � `� \\�`�� \ �
' 3g 1 1 f � - T i Y \�� �. � �� � � _
' o.a oas '_ " _'_ __ '" _ _ '" _ _ ' ZS _ l , � ' . � \ \` � . � �\'. �\ `',.`_-_. _ �•\�\ LEGEND__
� I r 23 i i� n ou � � � � � � � `��� � � � ♦ ; ' PRELIMINARY
om , ,'r � !��, � � � � � HorvaacoHsmucnon
.1 .r om• � � I :� y I �� � \ \ \ \� �` / �Y � � �" — msnt-or-M�� �na !.20o3
ix���i.y ,xa �y / u �-u -Y - _¢a'f � ��/ / � \\\ \�\\ . � �� 't`J,'�j � - _ — %fCPOYDVNCPEPiYLK �
`e i / �.:
.. „ �. ,. ,. „ ,. ,. , „ ,
, �
, , , a ,� Z, _, � / , , ��� . ��C.��
� sn � � � � �� V� ����� uunz a coxsmucnox �
� ' _ ___ '__ _ _"'"" ^
, ' � \ F o� ' __ , _ _ _ ` \` `� \ y` ���� —ano—�ew wcarca�ows
" _ � �2
j _�_� ' � �� �� ` �m77an _"_ '_" "_ p r_..'B - IB ` ���� �\ \\� \ \ ��`\;\�\` �� � \��\ \\\��\�`, —vu— r¢.rrzxucu.¢coxraras
�
\� \n _ _ . ` � � \ \ .
. . �. - 3` . �j n n an 'r VW Aa � -^ �� / \ � \ \ � \�� \ _ ��. � _" _.s>i v�s-[nsnwc ca.rouns
\ • `�, '1 \ � i 1 � •` , I� � �� 21 37A � / . ' \, \� \ \ \ � \� �^\t,i � ��� eEr Sra+u deux wrn uu,naL Z �
� � ., - __� -- - -- -__-- -- - -- -� - - ,,, � � _ __ __ � _
: \ 78 � � es om � ♦ ' \ ' cnsnuc nam�onem c.
� � v on 19 _ _ '_ 20 s, a l \� � ♦ � � �\ ` � 1 , m�
\ \ \ \ -7 1 � ` �, � \ � �' VflCPOYD SMALC O N m E
' ' \ m ou \ � I i iw ow ppv� � I � ♦ E'^ m� .
� � ,� � � \�l ',, �1 .� I . V.r. E � ' �\ \ � �\ \ \�\ \ � o.n raarouo..cn.a smcc.sac 2' 9$
I . ,' i ti, \ �1 ' wos :i ,.Y . - ,- ./ \ �' '� `\,\� `�� _ m o`�r� .
l \ �9 ' 1 � 'l '�'"' �v+[Fi__ \ � � � � \ prt[aror�a rtow f V y c
. . . ` ;'
i.
�, , .� ' _ '_ _'_ __ _•_ _ _ " ' ___ 1e�eirae � \ � \ \ \ �� � �c+o2
' . � - - o� � ' _ � '____'- � `` \ -__` 1 ` \� \\ — �_ OC9WPqN1 Q _ o
u'osi \ � , f� 14 . I�L^. \ � ,' � ,� � \ �� .•�\, muv.¢e.s..awno�ar W Nq V o k£
I . � �� R " " ' � _ � 13 _ I � _ a a�e' �I �\� `\ 1 �� � � � \ � \ : VI NILPLL�
11 4 1 f H on I � �i ov 1 �-�� ` ♦1\ � � \ �� \\ \ 1 \ n
�� �\� � �I � ' ur '`� I`\� �� , ��1�> � \� \ � , �i. �� � e.eesn w[�(��cn[s)
' 1 1 !;�i� �+� , ,,.r. .' � � _ � .- - - i P� � c.rtuworr ca[rrK[xr
� I . i� : � � � i �4 i +�.�. � -\ _--_�-__'s-- l�\- �
, ' ('I � �1 1 1 , i I wp � _ �����`�\ i � ...� _ -\ \\ \ ` � ,
� 2 { t1 �_J � � 1 � � /, I I ��. � ♦ , 1 \\ \ i �♦ � ioo m w.rzn wetEn wnu[E
s oii � I ! 70 -.
1 �\ f ` ` , t � � �i / a u .� 9 n o.m �iao-m ao' � ` �\ \ •� \� \� 1�I \ ` � wotv �etcn wxrea
49 �l 1 1 n ou 1 en on o ♦ \ \ \ ��' i .
� q \n ��,q u� le �n �d l� � .\ � \ � � � �
n ole �� 1� `�,', �\ � � � � � i I B .� �i i � 1 �� �� � �� .\ .
� � _ r oar - ' � � �� ti��� ...� � � �'-� �
j vre � \ ` \ \ \
1 1 r 7 �f - i � 9 ' �, � I� _.- \` \ �`� �� \� ��
.p - � � � CALLUTILITVNOnFIG1TION
4
. �
"" ^ 5iY b oa � � � � CENIEROFCALOfUDO
_ __ __ _� _ � I J / ♦ ♦ ♦
� 1 �,� ��f � ��1 u� � 1 �� � • _ �� ` \\ � � ��`� _\ �
' „ 06' _ --- - -� `�` -== 1-800-922-1987 €
40 1 � � ,�.0 oc� 1 ' 1 � �� n , 6' v� � <�� \✓ sir��mu°�o'awee.o�aw'c��v�rt �
' . ' . ` � . " \ ' "..�_
. ' 3 '' ' B � ' � .. . oo \ � ��� � mne��wv�onu°ia.�� -
� . � Z � �� �v ay .� m o.ee � • � v BA 37 . ` �Mt ` � � .. \� �\ � _.I___- _� ♦ �
41 I 42 n a�o� � � � � ' ' 1� 1 ___ " ('E .n on� m ou qyS�J I h � ` � �� � .. \ � , --�— \ Cly o/FortL Ldli�Cowod � �
' a an ox oss' `j �' � � � i � 11 i �5 �i I � i°� � Y/ i 1 � . � 56 ` ` �\ ` ^\ `�,S _�^ '' -�_'`_ MVROVED: � .
I I / �� � �� { � 'RM- 1 ` � \ , •�" GIYEnqneer pole lL IL
�s osa � n oa+ � V � � t � PROGiI �rtEr n r. .i��"�sron�r � GIEIXED 8r: Z N 2 •
, i , �
� � � r i
j� - . � -�. _ ! - ' - ' "- __ _ _ E__ C5�55 __ Y_" � _�� 1y Slam�ote UlNily Dole a.W a
, . i t " ' - _T" 1I ' � a c
� 43 u� ou � �5 _ — �8 ,c �7 " CHEfxED BY: a 0 i W W
' � � .' `-_au ou " �- � � 1 : � = ' ' - � _ _ _ = _ ' _ _- " _ '„ -- _ �e ou_= - _ ' " _ _- � '- .n oe� "' 1 -_�-'�-''-nr aas__- " _� ' � �-_�_ Pmks a Reomlbn �01� O= :(7 m
� ' _ __ _ _ !' �i _ WEOCED Br: �d W ,�,Z m
:- - `' ' � � . - J OS3 OSI l �" I tmlf En eer pole � e
� ' i I I r., i- ! i ' ! ' / - _ l� .�e au _ *uw Y-i' _ _a als + ' ' ,` '_\'l- fHEIXED Br: � Dole g ?U W��
� I I r . — r _ _ __ n \ , Y
/ ' � , '�I�I r ES-C � � �2 UR I � - , I II, MCX PL�N$XAV[9[EN RENENEO BY ME LOCK ENIItY P�'�[t W.
/ � ! r � ' ' ' : II II $MCf�i C$�5 I i I ! $i Y UI�YI 1\ �i ) I II;II RESVOXSbUO�YCK•.1MC NENCMWrG OEP�POIYLHi`�MC LIX'K 614003
`.� �` ���! ' I / i � i � ` i � 4.nc�� n � � � I 1 i � uro ee«acenrcss a TMe e.ieu.mrs.rweTMcm11we. o/n'.�...e.o. �
i! I:f ' , I i I II nd i 1 E u �L I 'I I I ann EwpeEen.a+M ia�t ann rpe weaw�er
i�i� ' ' ' I \ � ...J I � _�� � �� _ _ _=I� - T� i�I�� � � —1= �1 _. _ J ' � �T �� f =��_ _ I�� � ' i m 1�522�
_ ME FENEW OOCS NOl WP�Y�NAI W�N11M5 Cf IIEYS
1 = I � RC'KM SNKLSMO�BC�Cd51PUE0 N'I M�PE�SMC�SME
' I!I I I ' I \ , L_ _� ______ I) ; . ' ' �CCfVII.NCE fi fWIJItlN.KSGWLB4�iv BY ME LO[/.L
i �� � � / ____ _ -I � I uiv"¢E`�w�xco�oirawc�TMi cwsmucnw w�u TM�� SHEE i 13 Of 76
�__"__ _______________ ___ _�__"__—"—
,
' 2niond a.enod '
100 Yur polgn Srorm
Propoud Flmn Iw LInA Property Fllinp I �
D�[wtlon Pontl:61�-003
, RONIng Flow Tlm�(y) RunoX
�pe er o
.o•��vam Beairo k Lerqt�Type Sbpe VebcHy Travel Trevel �. C C'C�IMensiry lvae ftunoll Rumll RwaR
� iwm� rtdn lM1l (8I l%1 (Na) 1�) (m�) min IMvI (ac) c6) chl c!e Remerka
INLET 1
F2 f2 54 0.0 PA 1.0 1.9 0.0 0.0 5.08 OJO 0.8] 9.92 1.35 11.68 000 11.68
Ft F2,P1 5.1 095.0 PA 3.0 3.3 22 0.0 �.27 0.70 0.80 B.]8 1.00 3D.66 0.00 3068
F3 � F3 50 00 PA 30 3.3 0.0 0.0 5.00 0.]0 0.81 8.95 t.12 9.72 0.00 9l2 .
fl F1e,F3' S.0 205.0 PA 30 7.3 1.4 00 6.42 OJO O.W 9.17 2.60 20.80 0.00 20.80 •
' Ft F1�F3 7.3 0.0 PA 30 33 0.0 0.0 727 0]0 0.87 8.78 6.60 50.d5 0.00 50.45
INIET 2
Y9 29 5.0 0.0 PA 1.0 1.9 0.0 00 5.00 0.73 0.91 9.95 0.0] 0.63 0.00 0.63
F9 2G,30,F4 50 150.0 GA 0.] 1.8 1.fi 0.0 6.51 0.]0 O.BB 9.09 127 10.iC 0.00 t0.14
' f5 29,30,F4,f5 68 <80.0 PA 30 3.3 2.3 00 8.87 0.70 0.88 8.11 2.OB 14.77 0.00 14.77
INLET 3
FB FB 50 0.0 PA 1.0 1.9 0.0 0.0 '5.00 0.85 1.00 9.95 � 0.% 537 0.00 5.37
31 F<q Fe,F7,31 5.0 770.0 PA 2.9 J.3 3.8 O.0 8.92 0."!2 0.90 B.W 3.56 25.89 0.00 25.89
32 FOA,F6,F7.31,32 0.9 20.0 PA 1.8 2.0 0.1 0.0 9.08 0.72 0.90 8.00 3.63 P8.32 0.00 28.32 �
37 FM.F8,F),Fe,91,3Y,33 8.1 195.0 PA t.d 22 1.5 0.0 10.51 0.72 0.90 I.56 5.40 36.89 0.00 38.69
P9 F9 53 0.0 PA 1.0 1.9 0.0 00 532 070 O.B] 978 1.98 16.86 0.00 1686
'� 3a 39,FB�,FB 5.3 60.0 PA 70 3.3 0.9 0.0 5.82 0.71 0.69 9.59 3.81 3329 0.00 3329
3Yl4 F4A,F8,f7,fB,31,32,33 10.5 0.0 PA 1.0 1.9 0.0 0.0 10.51 0.72 0.89 7.% 9.31 fi2.94 0.00 62.99
3d,F8/,F9
INLET a
, 99 39 5.5 0.0 PA 1.0 1.9 0.0 OA 5.53 0.05 1.00 9.60 0.6] 8.08 0.00 6.00
26 26.39 5.5 2I0.0 PA 2G 3.1 12 0.0 8.71 0.18 0.32 9.03 098 2.87 0.00 2.8]
27 20,21,39 Gl 560.0 PA 2.6 3.1 3.0 00 972 0.71 0.96 ].Bt 1.8] 13.99 0.00 fl.99
20 26,27,28,39 9J 220.0 PA 1 4 2.Y 1.8 0.0 11.38 O76 0.H4 7.32 2.55 17.63 0.00 19.fi3
INLET 5
22 12 5.0 0.0 PA 1.0 1.9 0,0 0.0 5.00 O]0 O.B7 9.95 0.98 8.51 0.00 8.51
' 23 72,23 5.0 540,0 PA 2.0 2.] 3.3 00 8.30 O70 0.07 8.32 3.56 25.86 0.00 P5.88
24 22,Y3.Y0 B.9 010,0 PA 1.0 1.5 3.6 0.0 11.87 O.ZO 0.88 9.19 4.W 15.80 0.00 25.00
25 25 fl2 0,0 PA 10 19 0.0 0.0 820 0.45 0.58 B36 223 10.00 0.00 t0<0
2425 22Q5 11.B QO PA LO 1.B 0.0 '0.0 11.87 O.fi1 O78 7.19 d.l2 34]4 0.00 34J9
' INLET 0
15 15 8.8 0.0 PA 1.0 1.B 0.0 0.0 8]7 0.57 0,71 8.19 2.32 13.35 0.00 13.35
i6 15,18 B.0 0.0 PA 2.5 3,0 0.0 0.0 e.77 0.58 072 8.id 2.69 15,46 U.00 15.98
11 1i17 8,8 5380 PA 3.5 3.fi 2.5 0.0 11.16 0.60 075 7.35 3.63 20.11 0.00 20.11
18 iS1B 11.3 3050 PA IJ 2.5 2.0 00 13.31 O.fi2 0.77 6.88 45B 2422 0.00 2422
INLET 1
19 19 � G.5 00 PA 1.0 1.9 0.0 0.0 8.49 0.65 O,Bi 9.13 2.01 1A.89 000 1A.B9 ,
20 19.20 6.5 315.0 PA 1.5 23 2] 0.0 9.17 065 0.81 8.00 3,41 T2.13 000 22.13
' 21 21 8.1 QU PA 1.0 1.9 0,0 0,0 fi.05 U,65 0.81 936 0.94 7.id 0 W T.14
2021 1&21 92 552.0 PA 1.0 1.9 O.B 0.0 13.99 0.65 OB1 6.71 435 23]0 0.00 23J0
, INLEi B
11 n 5.0 0.0 PA tA t9 0.0 0.0 5.00 067 0.00 9.95 0.32 2.fi7 0.00 2.67
12 11,12 5.0 550 PA 3.0 ].3 03 0.0 527 067 O.Bd 9l9 126 1033 000 10.33
fl 11.11.13 5.3 26d.0 PA 2.5 3.0 1.5 0.0 8.74 0.8] 0.80 9.01 1.67 12.60 0.00 12.60
1< N,12,13,14 6.] 120.0 PA 1.0 1.8 1.0 0 U ]]8 0.68 0.85 8.53 1.91 13.85. 0.00 13.85
INLET 9
' 8 8 BG 0.0 PA 1.0 1.9 0.0 00 8.50 0.65 0.81 B25 2.37 15.88 0.00 t5.8fi
9 8,9 8.5 140.0 PA 1.8 4.< 1.0 �0 9.<5 0.68 0.85 7.90 3.77 2523 0.00 2523
10 10 5;0 0,0 PA 1.0 1.B 0.0 0.0 5.00 OJO O.BI 9.95 0.78 6.77 0.00 6.I]
9/1U . &10 9.5 0.0 PA 1.0 1.9 0.0 00 9.d5 O.6B 0.85 ].90 4S5 30.60 0.00 30.80
' MLET 10 ' . "
49 49 5.0 0.0 PA 10 1.9 0.0 00 5.00 0.85 1.60 9.95 02B 278 0.00 2.79
1 1,2.3.a9 82 2&5.0 PA 5.0 a.3 1.1 00 ].I] O60 0]5 876 2.58 16.91 0.00 16.91
] 1,I.3,),�� ].3 2W.0 PA <.B <2 1.0 0,0 B25 043 05] 8.34 d.18 IL21 0.00 21.21
8 1.2.3,7,6,A9 8.3 557.0 PA 2.1 2.8 3.3 0.0 11.SB O5 f 0.83 7.28 ].46 3426 0 00 3426
� ' 6A 8A 50 0.0 PA 1.0 1.9 00 OA 5.00 OB) 0.86 9.95 0.19 1A2 0.00 ld2
6 1.2.3,7,6,6A,a9 71.6 0.0 PA 1.0 1.9 0.0 0 0 11.58 0.51 0.84 7 26 7.63 3529 0.00 3529
INLEi 1 t
40 40 5.0 0.0 PA 1.0 1.9 0.0 0.0 5.00 0.85 1.00 9.95 0.31 3.08 0.00 3.08
. 03 a0,<3,d,5 5.0 4'lD.O PA 3.5 3.8 2.2 0.0 7.18 0.]0 O.BB B.B1 1.46 11.31 0.00 11.31 �
' 44 40.dJ,0,5,3),aa ].P B1B.0 PA 3.0 3.3 1.1 0.0 1129 0.]9 0.98 ]36 3.49 25T3 000 2522
<5 90,47.<,5,37,H,15 11.2 510.0 PA 0.5 1.3 8.4 00 17.fi0 0.�9 0.89 8.01 3.9B 23.�0 000 23.'!0
48 30,4,5,97,0118 1].8 190.0 PA 0.5 13 2.4 0.0 1997 0.80 0.99 5.W 9.4P 2/.91 0.00 4491
OSB OSB 8.8 0.0 PA 10 1.9 0.0 00 8.58 0.85 1.00 9.09 1.02 927 0.00 927
� d8 048,48 8.8 1]5.0 PA 1.1 2.0 i5 0.0 8.03 0.85 1.00 8.43 120 1042 0.00 10.12
O 058,C8,�� 8.0 375.0 PA 0.5 1.3 4] 0.0 1271 0.85 1.00 6.99 1.51 10.9� 0.00 10.W �
� � Q/48 056,a,5.F11,3],a0,�3d8 20.0 0.0 PA 1.0 1.9 0.0 0.0 19.97 0.81 1.00 5.60 6.04 33.B5 000 33.85
INLET 12
OS3 053 5.D 00 PA 1.0 1.9 0.0 0.0 5.00 0.85 1.00 9.95 0.18 179 0.00 179
OSa OSa 5,8 0.0 PF 10 1.9 0.0 0.0 5.84 0.85 1.00 9.58 0.36 3.<5 0.00 305
O51 OS}O56 5.8 ,U.O PP 1.0 1.9 0.0 U.0 5.89 O.BS 1.00 9.58 OSM1 5.11 000 S.T!
Smrm
RoN4g
' Inkt 1 Inle�1 ].9 �.0 Ph 0.5 1,3 0.0 0.0 ]2� 070 O.BB 876 8.60 50.59 0.00 W.58
STMH�% Inlet L2 ]3 28.8 PA 1.0 1 B 02 00 ].51 009 1.00 8.66 8.68 75.10 0.00 75.1d
� STMH-h3 INab1-9 �].5 586.0 PA 1.1 2.0 5.0 0.0 12.520951.00 1.03 20.5n 11C.19 0.00 144,09
INLETS Inbb1�5 1Y.5 333.1 PA 09 1.B 3,1 0.0 15.880811.00 838 28.861]1.11 0.00 111.41 . �
,. STMH-A-5 Inlqal-8 15] 296 PA '1.1 2.B 0.1 0.0 15.81 0.99 1.00 6.35 31.49 189.I0 0.00 199.]U
�Ink17 Inkl7 14.0 0.0 PA 1.0 7.9 0,0 00 1399 Ob5 0.87 8.71 d.35 23.70 000 2370
STMM�ASt Inled 1�8 14.0 47.1 PA 0.9 t.3 0.3 0.0 14.33 0.66 0.82 6.65 626 30.25 0.00 3425
STMM-A�] Inleb 1-8 15.B 9BB,9 PA 09 1.8 0.5 0.0 2028 0.80 1.00 5.58 3].]0 PW.65 000 20BG5 '
STMH-A-e Inlau t-8 20.3 252.9 PA O.fi 1.5 2.9' 0.0 23.13 0.80 1.00 5.19 3l.]0 195.51 0,00 �195.51
FES�A4 Inlebb8 23A 1D1.1 PA, 0.4 L2 L9 0.0 14.5]0.80 1.00 .5.W 3].]0 189.6C 0.00 188.44
INut10 InIe110 11.8 0.0 PA 1.0 1.9 �0.0 0.0 11580.51064 726 ].83 3529 0.00 3529 .
STMH�B�1 Inleb9�10 11B 27,1. PA 2.0 2] 02 0.0 1175 0.57 Ol2 722 12.18 83.06 0.00 63.OG
FES�&1 InIeU410 1I.8 222A PA 03 0.H 4.0 0.0 15.71 0.57 072 8.3] t2.18 55.80 0.00 %.64
Intet 11 Inlel t t 20.0 0.0 PA 1.0 1.9 0.0 0.0 19.97 O.B 1.00 5.80 6.0 33.85 0.00 33.95
STMH-E-1 INals11-12 20.0 Al] PA 05 1.3 0.5 00 20dH O.P1 1.00 5.53 0.58 38'.3B 0.00 36.38
In1e112 Inleb 11�12 20.5 344,3 PA 02 0.8 6.9 0.0 27.96 0.81 1.00 4.75 8.58 3127 0.00 3127
TUWIFbw 6ileroYl2 17.9 D.0 PA 1.0 1.8 0.0 OA 2736 O.GS 0.81 475 73.00 181.93 0.00 28i.93
To Outnmbn PurM
ToIalFbw INeNt-13 27A OA PA 20 2] 0.0 0.0 2�.36 0.63 O78 475 44.53 185.BB 0.00 18590
Ta Retentbn Pond
Note:
- � a)Codea the diennel type br vabdry cekubWna. �
PA=Peved,PL=PestureBLaxm,GW=GrmeetlWeteiway . � - ' � �
�AGPM
m.e....eA..�aav . . , sveam
,.- - -� --��--��--�_-- ------- - _. �—
► f i��,, . ':L �,,� '- - 11111119
� , ��, !��'".����� ��������
� � ��. �°�''���° � � ' � ' .'��,� , '�, '"�
����
��' I� �� ' ,,�al � ' ' � ^� 'i
I I �� � , �'� �i. � �� '���
I � ,a� � �� �
a y�
���II � II �� � 0 �Y�� i �a �
� ' a? ' 0 �Q�L�ii"�� �6'°.'�ki .�. �
�i�si�� � " � x �, 1
♦ � � 0: � ' S�+�{�'� r ., �.u� i
I ���Ipl � ��� � � � lj�� . �R
� ���� � � ili . � � ' �--- /�i 3 .!:
�� � • ��• � � I� � ��i:+ �.. �. • . �� ��'�`Y/, �i
� . �� � � �fe.`ir� �� "i/'�
� � - . ��. �; �� �ii�,. ' � . . . �,,:�t� �`�
! �� , � �� °���;;,, . �. � _ ,�,�, � x� a000000�
�, ; , � � �:,,� ��� � :�
_� ���I� �� � � � '`�:,�., or�� ��, -
�� ,�, �� �I�� � � �. o�� •- .'-
, �������� `�� ��rl�� ��� � �� �•�• av� •
� � � �� � � �� ��, .:. . .- . .
� 0 �� � i
R .��� ,��, � o��; �,. �� .�� � «.. � �
I ��� ���''----- ���������,ii. �. �- - �,
� �r�,�a=i•��s�=�n�.�-�,.���rii�� �� `�. � ��i - -
� i� ,. �T I� �s� ��f r� ���. .:�� '+� �r. �
'�� � �l�/e �'(��� �E►��r� � � / " I
a��',��I;!��-�.��e��i� I'f�![�� � ���'� � .r,� �� . �.r: .
� ► i �,,��1r��►�������II ���,��:, � .��,�.�' �.
�,�� -��-�,, .���.��.� ��.��,�,�,e �..�_ e�, .._�; , , .. .� . ,�. ��.
.�
�p '7-+.�.� ar�r 1.C:��'�� �dr��-��>� c r.i►� ! :Y..r �f��I� �
�.65{�'��'Q`w'�'��CT`�iQ �_i���1R�'vi^.'7.�Ta�•_.�� '`V'!iie�..���3��I►��" r ��V`` .. +.� � i
'�'y`�Y��.�/��'���'/�l�,Sl�1���r��L' .�r . y �c�3`��''�\`/i,� �i.'�.
R1�1 �at�?�J �t==�� �9vwai�- ;�-"s.y}v .�.�srTls� ��V. "•
�,!�1�� �� �1� ���►w�� �e1�� � �l�s � `��^� I�A��'�v ~: �;�jf�
���' ����4���r+��������6i��.►�,��j!J�i��� ����L,�,����,���,�� ` -�
u, �
�' f�� = 1�; ..r��= -- ...��i��..�� �� i _ �,c.- - ����� ♦ ��� �.
�..�. ,r..,...�s.�os�s.�i �i��- -�<e �I� -
���+� ,��(��j`��i�- ���-��-�,����, I�- ���--���'1, ' �,�c�`�,."'.�I���n� 'i,�l,� :�
����,±�I� ��i�.�!l�I�� ����'-�1-,���Vi��'V.I��L:'���I ' ���i_�;�'C��91���'` I�� ��'�',;
�:�{{{��1�� �d�����.�r���.����==s�l ��.�e�-- •'�. r"��' �•_�+�+.`.`._:-_,�� �`� � ' '
�l��I�X�Ii`I�Ilill'�`���.hi�y1L����.���LS-��.� �-���.�`•�., �.,,�����'�I`•-�� �� �`���I .'•.• � .• .
t ?� 4 I III
�� ���j��II������i'����I1��"��E��;�������%��o������ ��u��_ ,�,��il'll�:�„_ ` I ° ` �, � ��,
II
!�� �I,�� �� �;��_�����a����l�� I�r•�'������a���� �I II� ,�_ -
�` i;:��;.�1' I������.����i`�=�� �" �.,� �� ����—,��—;���,��! O��i'I , ,, ��, .
�� ��I� ��1�� ; �i!� � � �:, � (� ;� .� .; ai � �,.�; _ .. -
,: � �� �:�s��.����I��������J,I ,, �ii�.'�i����� ����! - ��� ;�
�� - � I,i � �o��������. �� :�_,�-.�--��m ��,m�-��._�,���;�_�� � � -
I� � 1�1 �1�'('Pll �1 -�/#�� ��Y A! V�q Y� Pr�.��1 �� '�� ��
lil I ��� {���1�.Y?f��� ��/�."�".���fft�Rfi��Rf/IM1���. -�'�' �I` {` \ 1�
�� � � r� �� �� � �;1�� r �I\ �� � � •.• • _
� ,, �4t:r4�4l�'.. FNa. ^ Gi •Y �� �• �� �i - � �� IIII� ?�� -
� ' .'� �i i� `� n ' ' � �-� � . . ..� . . ', �,
l�:it �+'
'�+ �� � � �ju�'`a ►� I��F'..1�llil���!����y�� ; g ��I �9������� , � � ��
� P � �1�1� �'�'--�'�'�l����.���'-.�.'�J'�����'���1'��'�' � �a���ai �� � �II � �_ .� �� _ � ;�
� �
A ,
1 •e.�i .—�� � a''��:�• --.-'� s�`�:, _ - I� � � � � ��li,�__�,-�� � ,',�"�' e
�'. -- �� � ; � . _ : � � �_— — .., �-. � ^,..
� r �. - -F 1 � � � .. .. .. ..
}�, � �� � � � [�N���II�#� ��R� ������,, �� �..,- � �.� = �,�� ,�... ;.� ao
� �� � �� ��� i � ���� A� �� �, �� � � ,;%���, -� �, �,�, �Iw;
a�a���lflil;l �����,;��'����� a ,�► � � LL'r..���� � „a�„��,�-- ��, -� .�.�,�,� �,��1 � ��r;� ,..,
' : _ ._ i� I ' ������ �
C•���ryr==C3'r.� �.��..l.����yll�G���i y������w ' �� � �::i:�';'� ? .•y ` :::� -kiNw �'}�y.�.:';1�11� '� •
F w� �_��„ -,..� �.. ,}... ._c=•y -p=:n �.�F � 1,lI �- �I ""i� � , � ;,: ��.L��,-�� •���,��� � �� ���11� �� '/
��7�, _ , __.._.. . ( � V� A II -,
YI q �Id4/'r�sdo���Y°�npwif� �.�ra/4��M��n���i+� ���7�III1 �,���5 N�����Y�� I��1\� ; ���.,�„t� 5 �eL �.���� � � i.•�I
�__=\"7v`�_"'�v`_..=i-___��.. . �r'''e'��l.q�' 1. _ �.�4 � �� , .�� a x ' � . j � �a �t;
A.� n� e������:�..�,�� ��i!��,�-►��lll'�1��i� �.�,���y«�, ��at;. ,�� �t ��� �,-%� �� a.l . .. . . .
�a..-,�=--- r �� � I'�
' , g�l���n�����11, . ���..,�,�.�:_,::,_:.�.4� ���� e�.:d� � ,.� .l�ll � ��� �+ -. ..
`'� � �� � g
��1 �����C .A��� �I��'i- �� ii l; ��.1� y � \��-. __�1��11.,11�.,.�p�. - � (�� ' _ � :�� � �:
�� ���� � ,—����,,_.�� ��! �a111��r�' 'lllfl I�������,�='�:�,.�...,:u d�;����a-��o� � - - � ,( �� � ,�.�. µ
li ,► ���-/�✓� �.� 1 � �� �� `===T-- e a�����'-��. a:r i �'��J ��1 ���� � � .�,�� �
�'�1� ��<- .. a�► � 11, '��� � �� ��-.r. � f!/.� ��� ��
i ��� yA,�, ,��e��.� �a , � `Si� �•� � ,,.v��!��' �� . J",',���'D�' ��� ��\ � � e � .
��[] /�o --;—-:, ., - � � �p�pn�l���l��� �y.����� �� , � I �� �t ��,� �� ���. � ,� ,, _...
�!�, I����-�--�� �u�pp�►ti��«�.�.. T+Mw � ����.._,Nyyrr./��, ��� 1//r : �A�, �,� �;a�� � � �.�
��4�l�f� �. .�� ��,� 1�".,1 :���������I������ �� �f�■��,l�.���q ;` � �%�'I��i� ' j��'� 'L��p��� �I�..1�I. ������� �� ����� .l�..
�� ry1I���.ury(�� .����IPI�� �"I�'i a�` -�� .f 9 ��!I I�5���� ( � `�-.�/;,a,��-��,�����oa4 -;.,,ei �� �
I� �;!�,a�.�.��,ti���(`�. �,y��/�,�r' �,��N�C�������,p,��!.���� I �'�,�.v �'=:�=o _ ��.E�: ,��� ��� ��
. ��� 3 .1.���C ���1���• �-��'����_��.�[t� ��! �.•�\ - - �� :'ll��� �:Y..� r:,i.
eG.� ��s�e��'�a��������r3 .rc�'.v w.�s�sp����WCa�.����" _a�r�i , �I�I��l , •
- ^�"'�' �yL�--� � 1��_ �G ��� .� �:.��.����n�._-c�
a.�., Y 3i�_ � aa.. r�r� n.� .,E,��� _.�_ � '
�-/���.���_ ����'ta.c..��.'��_9�.;wtg--���'oaT3f�L��.F�'��ce.;=��^'������..� ���'--_�— ��s �`.'��`�m�� � :
s�/g �..v� ��a.��ava • fade, 3�• �_s.c` �'!A Lii�� e 7'it��,sw �' �. c'�`�1 � .
�a�P�'_�: i� .. _ -- 9-4��,�'7:s'eft.�.a��r,�xT�sa�✓��araesrw.�?e�.e��..�e��`-`�r,rr�i� �.(S-��e�-�� _ _ E'!'��ai�i
.. a.s���� .����.. ��
�I� i/���su�rr��i��r��y ���i�r.�us����� . =c .. ._.. si-r-_._. aww.w���� �" —�� �1�=� �"i�� �d
` � ! lo• i p a d�r �� r r �v��� ��.�.�=_-` ._�_ `--..�-e�� ��j +—��a
! ��11� ��4��W:���; �f�i�l,�i ���� ���-- _ - __ _ �9iGr��`���� — — - — ��.,
!�d�j,���—=-�;iL(���--�__- s _ ,=�,a.•,.o� �:;�G'►� �o.,.�,_.�,.._� '�� k'��
�-=_� -
-�
!I'
1.,�{. , . .�
iII1+ N '' _ . , , �.
. .
.
- - -- - -
-
tc='�=—=-- ' � � � � � . ��
,,.
.. , � ,
�I � -
. . . __
ti - � .
. ��� �� ... , • . .
. . , -- �- . , . . . .
_ --
` .. . � ■ ����'� I%�'�RT�_IF . _ ... . .� � . -
, .
' � a HYDROLOGY TABLE �
`s "s.
) F$ � Design Composite
' Poirrt Basin�s) Area(acre) "C" �(ds► (�ao(�)
�
1 1 1.18 0.65 1.78 8.89 0
2 2 0.76 0.40 0.54 2.51 '"
• 3 3 0.37 0.65 0.57 2.85 �
' a a o.as o.50 o.ss z.so DRAINAGE INLET SUMMARY . GENERAL DRAINAGE NOTES
5 5 025 0.65 0.40 2.00
6 6 2.68 . 0.65 3.92 18.94 FLOW �. ai sveei. ae���dy+�.er. �io�m ss.««ia.ota �:o-�cuo� :nan c��o.m m c�iy o�
INLET CONTRIBUTING vor� cou�m s�o�aaras ooe svedreacor�a cmre�i ot ao��o��,�c�uo�of ine oe.eiovm<m
k � � Q.�7 Q.6] Q.� �.42 INLET SIZE �q�<em<nt Ontaining to tnu EeMopmenl. Any cona�roctim otturring inree reae olta
NUMBER BASINS (CFS) �u�� �^ ^� - o
' � 7 7 _ 2.19 0.65 3.33 16.56 _ e.ecviro� ol Ine aeMopmml ognem<n1 snon rep�iro�e-e�om�ou«i o��ne o�ons ny me -
7 Fl-f 3 50.45 15'Combinafion ���Y Engineer .no�,oy.�a��«�^a� �n�y e<moa�m�o�io.m �o:m�ao.aa o�a
;�' 8 8 2.37 0.65 325 15.86 :n=���Koue�.���.e�i ai mei lima. y.r,e� L
�� 9 9 1.40 0.73 2.52 12.11 2 29, 30. F4. F5. F6 14J7 10'Type R z. rn� py�. ,�:a mam�o�am m,mee,o�di t�o.���a�.ya,�a�taiue.c.�oPo�o•�a« a ag'�a E�-'�S�-.�
, a anorn on ine a.a.inqv ❑ :M1d�ee In<reaponai0ditr ol Ine canlmct« to verily!ne �F_.'+�y��
�g 10 10 078 070 1.41 6.77 3 31-34, F4A, F6-F9 62.94 15'Combination �.��i�,�e a�a i�mm�oi on��a�.q.a,�a��u�u�s aiaiy m�.w��o�me.«x. esi�< o=g:Yo v �'��9y
Canmencinq ne�conslrvclim. l�e cMtrocla s�all De reeponaiGle la�locolin9 unknorn �j e:� �.� ye�.y
11 11 0.32 -0.67 0.58 2.67 26-28. 39 ��a�, a„i��u�.. �' u�'6 Y�•°'-
' �-�� 4 � 17.63 10'Type R e�a� ��'d�. s� rre��,
�}� 12 12 0.94 0.67 1.56 7.69 � g�3b� : "Yy:s?.�
� � �j '1'z-'z�j 3Q.7Q 2�'Type R 1. Tne Engnen �no naa preparea mne Plan�. DY ertculion ana/a seai nereol.ao<s Q 6� '•.p � qdy
13 13 0.41 0.67 074 3.42 n«vey aa„m.eao«�se�my�o ma cny oi r«�Cdine, m a mna ea�r eMer<��.r oi.om E �/. s
�F'� '�`"�y"'3 y �
�� fj �rJ-�8 24.Z2 ��'Combination Engin<eri.M. la onY erraa mE wni�aiona contoineC in tnea<pians.anE oPOrowl ol e[�E�Ya i8s4{'tl
a 14 14 024� 0.75 0.51 223 mo�pa�s oy�ne amc�or ol Enqineoinq snan�e� .a�e.ro ma En9f^ev.no nos p.�oa°a
15 15 2.32 0.57 2.80 13.35 7 19-21 23.70 ���TYPe R �ne.�o�oo.oi on s��n.�spwaroaiy. r�rm�r. in.Enginea n<.mr oy.eee io naa
. nwmi�..an raerGea�ioMa. o�a a��m.n�cn mor o.�:��.a.�a�r N.«a o�a
' 76 16 0.31 0.67 0.57 2.58 om�es�o��co�m�nea� tn�:e vian�. � '
8 11-14 13.85 10'Type R �
�7 �� �.� �.67 �.� 7.� t Prior 10 commmcemenl ol any constm<tim, ine conlmclor sna11 qiro IM Cily +�
9 8-�� 30.60 ��'�mbinaGon Enqlnening Oepartmmt(I21-6609)anE Eroaion Conlyd impe<trn(221-6589)
18 18 0.95 0.67 1.63 7.89 : a
� 19 19 � 2.01 0.65 3.01 14.89 10 1-3. 6-7, 6A. h9 35.29 10'Combination �•��r��•U•)��,..ea,�<.,�ou«. .
5
20 20 1.40 0.65 217 10.40 . 11 4-5.37.40.43-08,OSf � 33.85 s. uon�.�o��.ol maite aaMaqe loclflfaa zndl Oe tna,.w„�:arir ei in�o.�rir a� � �
, 10'Combination ,.�<... �,W =J W
2� 2� 0.� �.�J �.� 7.�4 �Z Q$-3,Q$-4 $.�] $�TYPB R 6. Ai�r<commrnCationa ol I�e Ind Ganaqe ond mosian conVd stuEy lor Ue �a sW mi
22 71 0.98 070 1.80 8.51 a�.�iopm�m er sea.-e.o.� .ni e�co�.�puea.�ta �� -a �u
23 23 � 2.58 0.70 4.11 �g_gp FUTURE Fi-F16 ;u o� .� ;�
].Priw lo find'mspttlion on0 xceptanc<CY Ine CitY.«rtificotron ol Ine Manaye
locililies.Ey o reqia�ereC D�ofessional mqinev,mml De mDmilleE lo an0 opproveE Oy '"�
24 24 0.53 0.73 0.97 '478 � . +n�vo.m.a��.mriy
' � 25 25 223 0.45 226 10.40 a,v� �e„�„��,�;m a�e mmu-mm��e���ioomMi., ce.rrcoeo�ol dl banage Ixiiilks
'� '� 0.'.� 0.73 0.� 3.16 znai ee mOmittM �o me smrm.ater uu6iy o�ims� �.o.eexa o��a to me measa o�a
«.rrcoi<oi o«�pm<y. im�ae�a mi co�ucoern, a.speci/ieE m m�e�.Mopm��i
27 27 0.89 0.73 1.67 8.04 POND SUMMARY aq«<�^�^�,�^�•�e�A.ema��a�qm�s�am.m«mrry ai i�as� �.o.«xs o�b��o me PRELIMINARY
� . - 28 .ZB 0.� �.73 �.� 6.�4 ' rN<oae ol u cerlilico(e o1 occupancy lor w<�lol. NOTFORfANSTRULTION
MaY B.2Wl
29 29 0.07 0.73 0.14 0.63 0. r«,na�m�,a.e�.<i�mm�-, a.i�r�a���oi ai�mo��ay� ia�a����.snai e�
' SPILLWAY VOLUME VOLUME suomiuea m m<5t«mwa�a uUNr��a««aanc<.im on cona���ona as prncneea ey me
��� 30 30 0.13 0.73 027 1.17 POND DESC ELEV. PROVIDED RE�UIRED 4eWODmmt oqreemmt e:.«�o��a.�m m �o,�e�u�e a.v«+�r�o�a or m.a��op�m�
aq.��mi a�a«�oiea.un m�s a<movmeoi. i�a��aoa mi�nur aew,, o:w«�r a;n
� 31 31 2.08 070 3.56 17.15 (�) (AGFT) (AC-Ff) me ee.eioommt ay.�eme�t.m�:i ee :�em�u�e ta m�stwm.oie�uta;ty at i�ost ao
32 32 0.07 0.&5 0.17 0.70 RETENTION POND �«ts p��w�o m�r�i�a�e o�a rnt�iKote oi occ�paicy iw s�cn w�.
33 33 0.18 0.85 0.43 1.79 � (Filing I only) 5021J5 21;68 21.51 Dsc�orca Poini�:°:`e a�i ex�n«���":. a siey�c�:v��u�o�.a��.�y wo.��.oi�.
, 9 � ��wa� - q��s nm a:�mm senn.cnonneL Brigalim ailcn.o.
34 34 0.32 0.85 073 3.18 o�y.at<n oi tne���t<a s�atn. Z
35 35 0.11 0.85 026 1.09 BASINS CONTRIBUTING 7-40, 42-45, 49 9. "° cois1ruc0oi ac0'^�'°s^'�s���^'v�r���n m�s�a«oi coio.mo v«m�����e v�o<�s 3 �
br"9wm�ota Drscneqe esaociotea.iln Consimclion�ctiNtY.' Ia inlormolion.please O �
� � Q.�� Q.�$ Q.�j �.Q�J contact Ine CdaoEo Departmenl ol HeaI1M1.Wata OualitY�^Ird Didsion.WOCD-0E-B2, �
37 . 37 0.62 0.&5 1.26 5.59 �.wo cne,.y n«k o.n�so�m. om�..eawaao 80224-1530. Rttmtion: Permitz o�a Lv 2m �
1 RETENTION POND 5027.75 21.68 15.51 Enlacement Seclion. Pn: (303)697-3590. v
' m O`cYrv�
37A 37A 0.45 0.85 0.95 4.34 10. Bmcnmak5: Lxol Entily surmy. �V'm^+g
38 38 428 028 3.18 14.11 vv�Ka oowm: C fr.c"_mo^m
1-40, 42-44, 47-49, e.u.r+�me�. NGVD 19I9 unoEj�s�e0. Elev.s 50]1_90. Q y=p�m^.
39 39 0.63 0.85 1.37 6.08 � BASINS CONTRIBUTING o«�.�P��: cay oi v«� eaime 97-1�.Hatneasl cwna oi ew��r aooa s�om ewoiy w o,00���
40 40 0.31 0.85 0.75 3.08 OS4. FSA-F16 Rn«;:o 1m�oowm°0'�";y'u�:�.��w.�. v� ,..LLa�
' 41 41 0.47 0.85 1.13 4.68 , r+.i.�o.�ais. E-]dSe}OS.6J .
7 RETENTION POND 5021.75 21.68 19,19 D<ac�;o��u�: eaomao State Piane CoorUinales N�0 B3/92 Dalum. Ho�iiontal Con4d
42 42 0.86 0.35 0.57 2.61 oo:<a�v��cs vo�i 'euo'.
Fi F1 2.65 0.70 4.23 20.59
F1A F1A 1.48 0.70 2.33 11.68 1-40, 42-44, 47-49
F2 F2 1.35 0.70 2.33 11.68 BASINS CONTRIBUlING
, F3 F3 1.12 0.70 2.07 9.72 OS4, OS6; Fl-F16
F4 F4 1.07 0.70 1.94 929
F4A F4A 0.13 0.67 0.25 1.08
FS FS 0.87 0.70 1.57 7.03
FB F8 0.54 0.85 7.27 5.37
' F7 F7 0.81 0.70 1.39 6.91
F8 FB 1.59 0.70 2.68 13.37
F8A F8A 7.61 O.JO 2.55 13.03 N
F9 F9 1.g8 0.70 3.45 16.88 �
F70 F70 2.20 0.70 3.50 16.80 �cE rH E oFc�oniFOR,�oo F
' F11 F11 1.35 070 2.39 1172 �
F�z Fiz 3.56 0.�o s.ao z�.az 1$00 922-��87 � W
0
F73 F73 1.31 O70 220 10.95 fo+�����+o
�so�ew�o-uauocwv�.�.h 3 Z
F74 F74 7_75 070 1.94 9.80 . ����g IL N
F14A f14A 0.24 0.70 0.48 2.08 Z rn r
Ciry of Fort Collins,Colorado TNESE PLAN$HAVE BEEN RENEWEO BY W 0
F15 F15 �.02 0.35 0.74 3.36 iHE LOCAL ENTITY IOR CONCEPT ON�Y �f z
' F76 . F16 0.88 0.35 0.65 2.94 UTILITYPLANqppROVAL a= zw
F�7 F'I7 2B.M12 O.�O SB.SG ZOB.7Z THE RENEW OOES NOi IMPLY O
AGPR0�40: RESPONSIBILITY BY TME RENEMiNG � a(J
F1H F18 1.62 0.70 3.22 14.04� ul�(�� ooie DEPARTUENT, n�E lotnL ENnTr �F a�
ENCINEER, OR iHE IOCAL ENTITY LOR �a W
fI�ELXEO BY: _. RCCURACY ANO COitRELTNESS Of THE q O Z W�
� �� OS1 OS1 L58 0.85 2.14 9.96 raie:w�,:i�.m«mr�r �= C�LCUUOONS. fURTHERMORE. TNE =z w Fa
, �$Z 0$z �.86 0.85 z.59 ��.3$ CHEIXEO BY: RE`AEW�OE$NOT IYPIY iHNT e J U
' � $�wm�0�n UIM� Dp1e �ANIITIE$0�ITEM$CN THE PLAN$
OS3 OS3 O.�B O.BS O.A� �.]S ARE THE��N��W�NIl11E5 REWIRED. vxD�E[irq.
0S4 0S4 0.36 0.85 078 3.51 O�ECCE�Br. ME REVIEw SHALL NOT 8E CONSIRUED
Poks 6 Rmwpon Dole IN IJiY RE�SON AS�CCEPTANCE 0� 614003
�$5 OSS �.�3 0.85 �.92 e.sz fINRNCIAL RESPONSBIUTV BY THE
OS6 OS6 1 A2 0.85 2.06 9.27 fNEIXED BY: LOC�L EN➢iY fpR ApDIT10NAL o^•��^�
OS7 OS7 0.46 0.85 1.00 4.SB ����K EM�M �� WANIITIES Of IIEMS SNONN rHnr u�r
'- �; -� �� -- GEC[EDex: % BE REOUIRED DURING iHE CS223
_ � �, .. �� Ca+smuCnor�rH�sc. SNEET 6 0�76
1
2
3
4
BLK1
BLK1
BLK1
5
6
7
8 9 10 11
BLK2
5 6
BLK3
BLK4
BLK5 BLK6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
7 8 9 10
14 13 12 11
1 2 3 4
8 7 6 5
1 2 3
6 5 4
7 8 9 10
14 13 12 11
13
12
14 15 16 17 18
BLK1
BLK1
BLK1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
36 35 34
33
1 2 3 4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19 2021
BLK
4
BLK7BLK5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK10 BLK10
BLK
11
BLK12
BLK14
1
2
3
4
5
6
7
8
9
BLK15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK15
BLK15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK15
BLK
15
BLK16
BLK17
BLK19
BLK18
BLK21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4 5 6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK11
BLK14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK12
BLK12
BLK12
8 7
1 2
4 3
1 2
4 3
5 6
16 15
BLK2 BLK3
BLK1
BLK
20
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1 2 3 4
7 6 5
8
11
9
10
BUILDING A3 STORY18 UNIT
BUILDING B3 STORY18 UNIT
BLK
8BLK8
24
12 13
14
212223
BLK9 BLK9
1021
13
22232425
BLK10 BLK10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D3 STORY18 UNIT
BUILDING A3 STORY18 UNIT
S S S
E
GG
EE
EE
E
EE
EE
EE
EE
EE
GG
G
G
GG
G
G
GG
G
GG
EE
EE
EE
EE
E
GG
G
G
G
G
G
G
G GGGEEEE EE
G GEGGGGEEEE
G GEEGG G G G G G GEEEEEEE E EE EE EE EE
EE
G GG GG GG G
G
G
EE EE EE EEGGGGGGG G
G
G
EE
G
E
GG
EE
EE
G
G
G
G
GG
EE
GG
GG
GG
GG
G
G
G
EE
E
E
EE
E
EE
EE
E
G
GG
EE
GG
GG
G
G
G
G
G
GG
GG
G
E
EE
E
E
EE
EE EE
EE
E
GG GG GG GG
GGG
E EE E E EE
EE E
E
E
EE
E
E
EE
EE
EE
GG
GG
GG
GG
GG
GG
EE
E
G
G
G
GG
G
GG
GG
G
G
G
G
G
GG
G
EE
E
EE
EE
EE
EE
EE
EE
EE
EE EE
EEEEEE EEE
EE EE EE
EE EE
G G G GG G
GGGGGG
G GG
GG G
EE EE
EE EE EE EE E
EE EE
EE EE
G GG
G G G GG G G GG
GG GG
EE EE GGGGEEG
EEG
EE GG
EE EE EEGGGG G
GG G
EE EEGG G
G
G
EE GG
EEEGG G
GGG
EE
EE
E
EE
G
G
G
GG
G G
G
G
EE
G
EE
EE
EE
EE
EE
GG
GG
GG
GG
G
G
E
EE
EE
GG
G
G
G
G
E
EE
EE
GG
GG
GG
G
E
EE
EE
G
G G
G
E
EE
G
G
G
EE
EE
EE
EE
GG
G
G
G G G
G
GGGEEEEG
G
G
EE
S
W
S
W
G
G
G
S
W
S
W
S
W
S
W
S
W
S W SW
W
SW
G
E
EG
EG
EG
E
G
S S S S S S
S S S S S
SSSSSS
SSSSSS S S S
S S S S S S S S S
S
S S S
S S S S S S S S S
S S S S S S S S
S S S
S
S SS
S S S
S S S S S S
S S S S S S S S
S S
S
SSSSSSS
S S S S S S
E
G G G
E
G
EG
EG
EG
EG
SSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S S S
S
S
S
S
S
S
S S
S S
S S S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S S
S
S
S
WW W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S S S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSS
SS
S
S
W W W
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
WWWWWWWWW
W W W W
W W W
W W W W W W
W W W W
W W W
W
W W W WWW
W
W W
W
W
W
W W
W W W W W
S
W
W
W
W W
WWW
W
W
W
W W W W W W W W W W W W W W W W W
W
W
W WW W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W W W W W W W W W W
W
W
W
W W W
WWWWWWWW
W
W
W
S
W
W W
W W
W
W
S
W
S
WS
W
S
S
W
W
W
W
W
W
S
S
S
S
W
W
S
S
S
S
S
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
W
GESW EE E E EE EWWWWWWWSSSSSSGGGGGGG
E EE EE EE EEWWWWWWWW WSSSSSSSSSGGGGGGGG
G
G G
G G
S S
S
E
E E
EE
W W
W W
W
W
S S S
SG
S
S
W
W
W
W
F
F
F
F
W
FFW
WF
WF
SS
S
S
W
W W W W
W
W
S
W
W W
W
W
W
W
W
W
WDP
DP
WW
DP
DP
DP DP
DP
EE EE
SSS
SSSS
WWW
EEEGGG
EE
W W
W W
S S
S
S
S
EE GG
G G
G G G G
W W W W
S
G
S S SGGG S S SGGG
W SW S SWW S
E E E
W
DPE E E
W
DPE
DP
WW W
EEE DP
WW W
EEE DP
WW W
EEE
GS
S
G SSGSGSSGS
S WSWWSSWWSSWSWWS
G
G
EG EG EG E G EG EG EG EG E G
E G EG E G E G EG E G EG E G E G
EG E G EG EG EG E G EG E GEGEG
EG EG EG EG EG EG EG EGEGEG E G
G
EG E G EG EG EG EG E G EGEGEG
E
G
E
G
E
G
EG E EG G
EG EG EG EG EG EG EGEGEG EG EG EG
EG
W SW
SW
WS W W W W W W W WSSSSSSS S S W
WSSWWSSSSSSSSWWWWWWWW
W S
WSWSSW
W
S S S S SWWWW W
SW SW SW S S S
W W W
W S W S
W
EG EG EG
E
E
E
E
G
G
G
G
G E GE GE G E
E G
E G
W W S W
W
W
W
W
W
S
EGEGEG
EG
EGEG
EG EG EG GE GE
GE
G
WWWW
WW
W W
S
W
W
W
W
W
EG
G
E
G
E
EG
EG
EG
G E
G
E
GE
EG
S S S S SWWWW
G
S
W
E
S
E
E
G
G G
G
E G
G
G
E
E
E
E
G
E
NOTES:
1.PROPOSED ELEVATIONS SHOWN ARE RELATIVE TO A DATUM OF 5000 FEET, AND ARE BASED ON THE
BENCHMARKS DESCRIBED ON SHEET C-001.
2.THE DRAINAGE BASINS OS-9, 24-31, 34-49, AND 51-52 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
THE EXISTING DETENTION POND 100. DRAINAGE BASINS OS-5, OS-6, OS-7, OS-8, OS-13, 7-23, AND
32-33 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO PROPOSED POND 200. DRAINAGE BASINS OS1,
OS-2, OS-3, OS-4, OS-10, OS-11, 1-6, AND 50 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
PROPOSED POND 300. A SMALL PORTION OF DRAINAGE BASIN OS-1 SHEET FLOWS INTO THE NO. 8
IRRIGATION DITCH, AS HISTORICALLY OCCURS. THE NORTHWEST PORTION OF BASIN 39 FLOWS TO A
HEADWALL AND PIPE W/ ORIFICE CONTROL, AND THEN INTO THE NUMBER 8 DITCH, WHILE THE
SOUTHERN PORTION OF BASIN 39 FLOWS SOUTH AND COMBINES WITH BASIN 49 FLOW, BEFORE
ENTERING EXISTING POND 100. BASIN 0S-12 FLOWS OVERLAND AND INTO THE NO. 8 DITCH.
3.PLEASE REFER TO THE SWMM AND RATIONAL METHOD CALCULATIONS WITHIN THE DRAINAGE
REPORT FOR BASIN FLOW CALCULATIONS, POND SIZING, AND STREET CAPACITY CALCULATIONS.
4.12" OF CDOT CLASS 'A' BEDDING MATERIAL SHALL BE PLACED UNDER ALL RIPRAP SHOWN.
5.RUNOFF FROM THE SITE WILL DRAIN TO LOW POINTS AND PASS THROUGH CURB CUTS, SIDEWALK
CHASES, AND SWALES BEFORE ENTERING STORM INLETS AND PIPES, WHICH ULTIMATELY
DISCHARGE TO THE EXISTING DETENTION POND 100 AND PROPOSED PONDS 200 AND 300.
6. RIPRAP AND GRASS LINED DRAINAGE CHANNELS WILL ENHANCE EROSION CONTROL WITHIN THE
SITE LIMITS. SITE BMP'S WILL BE IMPLEMENTED DURING CONSTRUCTION TO REDUCE SEDIMENT
TRANSPORT OFFSITE AS SHOWN IN THE EROSION CONTROL PLAN.
7.ALL PROPOSED STORM DRAINAGE PIPES AND STRUCTURES OUTSIDE OF CITY RIGHT OF WAY WILL BE
PRIVATELY OWNED AND MAINTAINED BY THE OWNER (SONDERS EAST). ALL EXISTING AND
PROPOSED STORM SEWER WITHIN PUBLIC ROW, WILL BE OWNED AND MAINTAINED BY THE CITY OF
FORT COLLINS.
60
65
58
59
6162636466
6
7
6
8
6
9
60
6
0
6
5
59
5
9
61
6
1
6
2
6
2
6
3
6
3
6
4
6
6
6
7
62
63
6
5
6
2
6
3
6
4
65
6
16263
64
62
63
60 61
62
6
3
55
60
56
57
58
59
61
62
6
5
70
6
2
6
3
6
4
66
67
68
69
71
6
5
63
64
6
6
6
7
68
60
61
62
6
3
60
61
62
63
65
7
0
6
4
66
67
6
8
6
9
60
59
61
62
63
65
61
62
63
64
6
5
7
0
6
6
6
7
6
8
6
9
70
66676869
65
63
64
66
6
0
65
65
61
6
1
62
6
2
63
6
3
64
64
58
62
63
64
40
45
50
50
39
41
42
4344
46
46
47
47
48
49
49
50
5
0
5
0
55
60
464
7
4
8
4
9
49
4
9
51
52
53545657585961
40
45
45
45
50
55
60
65
41
42
42
42
43
43
43
44
44
44
46
46
46
47
47
47
48
48
48
49
49
49
51
52
53
54
56
57
58
59
61
62
63
64
66
67
68
5
5
5
5
6
0
6
0
6
5
7
0
5
4
5
4
5
6
56
5
7
57
5
8
5
8
5
9
59
6
1
6
1
6
1
6
1
6
2
6
2
6
3
6
3
6
4
6
6
6
7
6
8
6
9
6
5
65
7
0
7
0
64
6
4
6
6
6
6
6
7
6
7
6
8
6
8
6
9
6
9
7
1
7
1
7
1
7
2
7
2
7
3
50
48
4
5
7
2
72
73
71
70
69
69
65666768
64
7
0
7
0
70
70
70
7
0
5857
63
64
64
65
65
66
63
70
69
6
0
5
2
6
0
5
5
55
6
0
5
2
6
5
6
1
6
7
5
5
5
0
5
0
45
5053
49
48 47 46 45
4945
42
6
1
6
2
62
6
1
6
3
6
3
7
0
50
50
45
42
42
45
50
52
52
59
59
51
50
51
55
59
60
67
41
49
42
49
42
50
55
60
40
63
64
65
66
67
68
69
70
1
2
3
4
BLK
1
BLK
1
BLK
1
5
6
7
8 9 10 11
BLK
2
5 6
BLK
3
BLK
4
BLK
5 BLK
6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
1 2 3 4
8 7 6 5
1 2 3
6 5 4
13
12
14 15 16 17 18
BLK
1
BLK
1
BLK
1
19
20
21
22
23
24
25
26
27
28
29
30
1 2 3 4
5
6
7
8
9
10
11
12
16
17
18
19 2021
BLK
4
8 7
1 2
4 3
1 2
4 3
BLK
2 BLK
3
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
NATURE PARK WAY
N
A
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
MOORLAND WAY
PARKLAND WAY
AMBLE LANEAMBLE LANE
S
T
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1
0.60 0.25
4
2.64 0.60
10
2.88 0.47
7
2.46 .56 9
2.43 0.54
11
2.38 0.54
3
3.90 0.51
OS-11
2.12 0.25
OS-2
0.34 0.77
OS-3
0.47 0.79
OS-4
0.51 0.77
OS-5
0.27 0.77
OS-10
2.17 0.25
50
0.73 0.34
12
1.21 0.71
2
4.54 0.48
5
2.51 0.446
2.51 0.57
8
0.54 0.65
OS-1
0.59 0.62
POND 300
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
EX COUNTRY
CLUB RESERVE
STORM OUTFALL
PIPE
FUTURE BAKER LATERAL EXTENSION (BY OTHERS)
EX PROPERTY
BOUNDARY
PROP BAKER
LATERAL IRRG PIPE
EXTENSION
1
50
OS-3
23
4 6
109
--
OS-5
5
0S-11
OS-10
OS-1
OS-2
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
PROP BAKER
LATERAL IRRG PIPE
EXTENSION
PROP RAIN GARDEN
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
OV
E
R
A
L
L
G
R
A
D
I
N
G
P
L
A
N
&
D
R
A
I
N
A
G
E
E
X
H
I
B
I
T
(
N
O
R
T
H
)
C-034
34 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'
036
035
034
KEY MAP - 1" = 1000'
MATCH LINE
SEE SHEET C-035
LEGEND
EXISTING CONTOURS
NEW INTERMEDIATE CONTOURS64
65 NEW INDEX CONTOURS
PROPOSED FLOWLINE
EX RIGHT-OF-WAY/ PROPERTY BOUNDARY
PROPOSED DRAINAGE BASIN BOUNDARY
LINE
PROPOSED STORM PIPE
EXISTING STORM PIPE & MANHOLE
RD
PROPOSED ROOF DRAIN AND STORM PIPE
PROPOSED DRAINAGE BASIN ID
ACRES / 'C' VALUE
PROPOSED DRAINAGE DESIGN POINT
DRAINAGE FLOW DIRECTION
DRAINAGE SWALE
1
0.60 0.25
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2 BUSINESS DAYS IN ADVANCE
CENTER OF COLORADO
CALL UTILITY NOTIFICATION
1-800-922-1987
MEMBER UTILITIES.
PROPOSED DRAINAGE BASIN SUMMARY TABLE:
PROPOSED LID SUMMARY TABLE:
VOLUME
PROVIDED
100-YR
DESCPOND WSEL.
(AC-FT)(FT)
VOLUME
REQUIRED
(AC-FT)
POND
OUTFLOW
(CFS)
DP
DP
DP
DP
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BRIGHTWATER DRIVE
CLIPPER WAY
WEL
L
N
E
S
S
R
O
A
D
H
I
G
H
M
E
A
D
O
W
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
STA
R
D
U
S
T
W
A
Y
TR
A
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
H
I
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
WANDER T
R
A
I
L
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
MORNING STAR DRIVE
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
DP
DP
DP
DP
5
0
55
4
7
4
8
4
9
5
1
5
2
52
5
2
5
3
53
53
5
3
53
53
5
3
54
56
57
58
59
6
16263
64
60
58
5
8
58
59
61
62
63
55
60
6
0
5657
5
7
58
5
8
59
5
9
61
6
1
55
6
0
6
5
5
2
52
53
545657
5
8
5
9
6
1
6
2
6
3
6
4
55
54
565758
5560
53
5456575859
55
55
54
54
56
56
57
58
5
5
5
4
54
5
6
50
46
47
48
49
51
52
53
54
4
5
50
4
4
46
47
48
49
51
52
45
50
43
44
46
47
48
49
51
52
53
4
0
4
5
5
0
3
7
3
8
3
9
4
1
4
2
4
3
4
4
4
6
4
7
4
8
4
9
5
1
45
43
44
46
6
0
6
1
55
54
56
57
58
60
65
6162
63
64
66
67
68
69
6
0
6
5
7
0
59
6
1
6
2
6
3
6
4
6
6
6
7
6
8
6
9
55
60
56
57
58
59
61
62
63
64
5560565758596162
55
60
545657585961
5
5
60
5
4
5
6
5
7
5859
60
65
58
59
61
62
63
64
66
67
68
69
55
53
5
4
56575859
55
53
54
565758
55
60
65
56
57
58
59
61
62
63
64
55
52
53
54
56
57
50
48
49
51
52
5354
50
4849
515253
45
50
44
46
474849
51
52
53
54
45
4344
46
45
42
43
44
50
46
47
48
49
5
1
5
2
45
50
44
46
47
48
49
51
5
2
5
3
5
4
50
46
47
48
49
51
52
53
40
45
50
37
38
39
41
42
43
44
46
47
48
49
51
52
53
50
47
48
49
51
45
50
41
42
43
44
46
47
48
49
40
45
37
38
39
41
4
2
43
44
46
47
48
45
44
36
37
38
39
5
2
5
1
5
0
4
9
4
8
47
4
6
45
4
4
4
3
4
2
4
1
41
42
42
4
1
40
39
38
37
42
37
4
0
3
9
4
0
4
1
4
2
4
1
4
2
4
2
3
8
3
7
5
3
42
41
42
3840
4
5
4
0
3
9
4
5
5
0
55
43
41
4
2
4
2
4
1
4
0
4
2
4
2
4
1
69
68
6
9
7
0
70
7
0
66
67
68
69
70
65
64
63
63 60 55
53
53
54
54
53
52 51
5
3
53
5
4
5
4
4
7
45
44
43
46
5
0
5
3
5
0
4
5
53
5857
64
65
4
3
5554
53
54
54
3
7
3
8
3
9
40
42
41
40
40
60
61
62
4
4
43
4
2
4
1
4
0
39
38
37
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY
BOUNDARY
PROP BAKER
LATERAL IRRG PIPE
EXTENSION
11
12
9
10
7
13 8
16
17
18
22A
21
14
20
22
23
26
10
2.88 0.47
7
2.46 .56
13
5.87 0.47
9
2.43 0.54
15
0.85 0.47
19
11.68 0.68
11
2.38 0.54
16
2.38 0.69
20
4.33 0.78
21
4.17 0.58
22
4.91 0.62
31
2.67 0.62
29
5.13 0.67
24
1.19 0.77
28
1.42 0.54
26
2.54 0.53
34
1.04 0.60
36
1.32 0.66
37
2.97 0.57
38
2.76 0.49
46
1.97 0.63
17
2.67 0.61
40
1.01 0.62
41
2.32 0.61
OS-12
41.62 0.25
OS-13
7.34 0.25
OS-5
0.27 0.77
OS-6
0.47 0.78
OS-7
0.09 0.79
OS-8
0.68 0.81
OS-9
0.44 0.77
12
1.21 0.71
33
0.73 0.70
32
0.60 0.64 33
0.73 0.70
32
0.60 0.79
35
1.06 0.64
14
3.92 0.64
22A
0.89 0.67
18
0.89 0.64
18A
0.35 0.78
23
2.01 0.59
27
0.32 0.67
30
1.04 0.79
25
0.20 0.70
4.70
8
0.54 0.65
27
30
28 24
29
34
25
33
32
18A
POND 200
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY
BOUNDARY
PROP BAKER
LATERAL IRRG PIPE
EXTENSION
PROP RAIN GARDEN
PROP DRAINAGE EASEMENT
PROP DRAINAGE EASEMENT
EX PROPERTY BOUNDARY
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
PROP BAKER
LATERAL IRRG
PIPE EXTENSION
1
2
3
4
BLK1
BLK1
BLK1
5
6
7
8 9 10 11
BLK2
5 6
BLK3
BLK4
BLK5 BLK6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
7 8 9 10
14 13 12 11
1 2 3 4
8 7 6 5
1 2 3
6 5 4
7 8 9 10
14 13 12 11
13
12
14 15 16 17 18
BLK1
BLK1
BLK1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
36 35 34
33
1 2 3 4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19 2021
BLK
4
BLK7BLK5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK10 BLK10
BLK
11
BLK12
BLK14
1
2
3
4
5
6
7
8
9
BLK15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK15
BLK15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK15
BLK
15
BLK16
BLK17
BLK19
BLK18
BLK21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4 5 6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK11
BLK14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK12
BLK12
BLK12
8 7
1 2
4 3
1 2
4 3
5 6
16 15
BLK2 BLK3
BLK1
BLK
20
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1 2 3 4
7 6 5
8
11
9
10
BUILDING A3 STORY18 UNIT
BUILDING B3 STORY18 UNIT
BLK
8BLK8
24
12 13
14
212223
BLK9 BLK9
1021
13
22232425
BLK10 BLK10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D3 STORY18 UNIT
BUILDING A3 STORY18 UNIT
DP
DP
DP
DP
DP DP
DP
DP DP
DP DP DP
NOTES:
1.PROPOSED ELEVATIONS SHOWN ARE RELATIVE TO A DATUM OF 5000 FEET, AND ARE BASED ON THE
BENCHMARKS DESCRIBED ON SHEET C-001.
2.THE DRAINAGE BASINS OS-9, 24-31, 34-49, AND 51-52 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
THE EXISTING DETENTION POND 100. DRAINAGE BASINS OS-5, OS-6, OS-7, OS-8, OS-13, 7-23, AND
32-33 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO PROPOSED POND 200. DRAINAGE BASINS OS1,
OS-2, OS-3, OS-4, OS-10, OS-11, 1-6, AND 50 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
PROPOSED POND 300. A SMALL PORTION OF DRAINAGE BASIN OS-1 SHEET FLOWS INTO THE NO. 8
IRRIGATION DITCH, AS HISTORICALLY OCCURS. THE NORTHWEST PORTION OF BASIN 39 FLOWS TO A
HEADWALL AND PIPE W/ ORIFICE CONTROL, AND THEN INTO THE NUMBER 8 DITCH, WHILE THE
SOUTHERN PORTION OF BASIN 39 FLOWS SOUTH AND COMBINES WITH BASIN 49 FLOW, BEFORE
ENTERING EXISTING POND 100. BASIN 0S-12 FLOWS OVERLAND AND INTO THE NO. 8 DITCH.
3.PLEASE REFER TO THE SWMM AND RATIONAL METHOD CALCULATIONS WITHIN THE DRAINAGE
REPORT FOR BASIN FLOW CALCULATIONS, POND SIZING, AND STREET CAPACITY CALCULATIONS.
4.12" OF CDOT CLASS 'A' BEDDING MATERIAL SHALL BE PLACED UNDER ALL RIPRAP SHOWN.
5.RUNOFF FROM THE SITE WILL DRAIN TO LOW POINTS AND PASS THROUGH CURB CUTS, SIDEWALK
CHASES, AND SWALES BEFORE ENTERING STORM INLETS AND PIPES, WHICH ULTIMATELY
DISCHARGE TO THE EXISTING DETENTION POND 100 AND PROPOSED PONDS 200 AND 300.
6. RIPRAP AND GRASS LINED DRAINAGE CHANNELS WILL ENHANCE EROSION CONTROL WITHIN THE
SITE LIMITS. SITE BMP'S WILL BE IMPLEMENTED DURING CONSTRUCTION TO REDUCE SEDIMENT
TRANSPORT OFFSITE AS SHOWN IN THE EROSION CONTROL PLAN.
7.ALL PROPOSED STORM DRAINAGE PIPES AND STRUCTURES OUTSIDE OF CITY RIGHT OF WAY WILL BE
PRIVATELY OWNED AND MAINTAINED BY THE OWNER (SONDERS EAST). ALL EXISTING AND
PROPOSED STORM SEWER WITHIN PUBLIC ROW, WILL BE OWNED AND MAINTAINED BY THE CITY OF
FORT COLLINS.
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
OV
E
R
A
L
L
G
R
A
D
I
N
G
P
L
A
N
&
D
R
A
I
N
A
G
E
E
X
H
I
B
I
T
(
S
O
U
T
H
)
C-035
35 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'KEY MAP - 1" = 1000'
LEGEND
EXISTING CONTOURS
NEW INTERMEDIATE CONTOURS64
65 NEW INDEX CONTOURS
PROPOSED FLOWLINE
EX RIGHT-OF-WAY/ PROPERTY BOUNDARY
PROPOSED DRAINAGE BASIN BOUNDARY
LINE
PROPOSED STORM PIPE
EXISTING STORM PIPE & MANHOLE
RD
PROPOSED ROOF DRAIN AND STORM PIPE
PROPOSED DRAINAGE BASIN ID
ACRES / 'C' VALUE
PROPOSED DRAINAGE DESIGN POINT
DRAINAGE FLOW DIRECTION
DRAINAGE SWALE
1
0.60 0.25
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2 BUSINESS DAYS IN ADVANCE
CENTER OF COLORADO
CALL UTILITY NOTIFICATION
1-800-922-1987
MEMBER UTILITIES.
MATCH LINE
SEE SHEET C-034
MAT
C
H
L
I
N
E
SEE
S
H
E
E
T
C
-
0
3
6
036
035
034
PROPOSED LID SUMMARY TABLE:
VOLUME
PROVIDED
100-YR
DESCPOND WSEL.
(AC-FT)(FT)
VOLUME
REQUIRED
(AC-FT)
POND
OUTFLOW
(CFS)
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
DP
DP
DP
DP
15''SAN 15''SAN15''SAN 15''SAN
25
3
0
24
26
27
28
29
3
1
3
2
33
2
5
30
35
40
4
5
5
0
2
6
2
7
28
2
9
3
1
32
33
34
36
37
38
39
41
42
43
44
4
6
4
7
4
8
4
9
5
1
5
2
52
5
2
5
3
53
53
5
3
5
3
5
2
52
4
5
50
4
4
46
47
48
49
51
52
45
50
43
44
46
47
48
49
51
52
53
3
0
3
0
3
5
3
5
4
0
4
5
5
0
29 29
3
1
3
1
3
2
3
2
3
3
3
3
3
4
3
4
36
3
6
37
3
7
38
3
8
39
3
9
4
1
4
2
4
3
4
4
4
6
4
7
4
8
4
9
5
1
40
45
36 3
637 37 38 39 41
42
43
44
46
35
40
33
34
36
37
38
39
41
25
2
5
2
5
24
2
6
2
7
2
8
2
9
53
45
50
44
46
4748
51
52
53
54
4344
50
46
47
48
49
5
1
5
2
45
50
44
46
47
48
49
51
5
2
5
3
5
4
50
46
47
48
49
51
52
53
40
45
50
37
38
39
41
42
43
44
46
47
48
49
51
52
53
30
35
262728
29
31
32
33
34
36
37
50
47
48
49
51
45
50
41
42
43
44
46
47
48
49
40
45
3
7
38
39
41
4
2
43
44
46
47
48
30
3
5
4
0
31
3
2
3
3
3
4
3
6
3
7
3
8
3
9
3
5
4
0
3
2
3
3
3
4
3
6
3
7
3
8
3
9
4
1
35
40
45
36
37
38
39
41
42
43
44
46
4
0
3
6
3
7
3
8
3
9
4
1
4
2
4
3
4
4
3
0
3
5
3
1
3
2
3
3
3
4
3
6
3
7
3
8
3
9
30
35
2
6
27
28
29
31
32
33
34
36
25
25
30
30
35
35
40
40
23
23
24
24
26
26
27
27
28
28
29
29
31
31
32
32
33
33
34
34
36
36
37
37
38
38
39
39
41
41
42
42
43
30
30
30
35
28
2929 29
3131
31
3232
32
333333
3434
34
5
2
5
1
39
38
37
42
37
4
0
3
9
4
0
4
1
4
2
4
1
4
2
4
2
3
8
3
7
5
3
28
28
25 24
21
25
43
4
2
4
2
4
1
4
0
4
1
5
3
53
5
4
5
4
4
7
45
44
43
46
5
0
5
3
5
0
4
5
4
3
3
231
3
1
5554
53
54
54
35
3
6
3
7
3
8
3
9
40
34
34
35
33
29
30
44
25
28
2923
23
25
28
28
2726
25
29
42
41
40
39
38
37
30
31
32
33
34
32
31
34
30
28
2
9
31
32
33
34
28
2
9
31
32
33
30
35
36
37
38
BLK
14
1
2
3
4
5
6
7
8
9
BLK
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK
15
BLK
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK
15
BLK
15
BLK
16
BLK
17
BLK
19
BLK
18
BLK
21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
7
8
9
10
11
12
14
16
17
18
19
20
BLK
14
33 34
35
36
37
38
39
41 40
BLK
12
BLK
20
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WEL
L
N
E
S
S
R
O
A
D
H
I
G
H
M
E
A
D
O
W
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
STA
R
D
U
S
T
W
A
Y
TR
A
I
L
W
A
Y
R
O
A
D
PLAY
P
A
R
K
L
A
N
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
19
15
13
15''SAN 15''SAN15''SAN 15''SAN
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
PROP LIMITS OF DEVELOPMENT
EX PROPERTY
BOUNDARY
(TO BE VACTED BY
CURRENT PLAT)
PROP DRAINAGE EASEMENT
EX PROPERTY BOUNDARY
PROP 6' CONC
CROSSPAN
INLETS
PROP TYPE R
INLETS
PROP TYPE R
INLET
PROP RIPRAP
31
2.67 0.62
29
0.67
34
1.04 0.60
36
1.32 0.66
37
2.97 0.57
38
2.76 0.49
46
1.97 0.63
42
2.13 0.50
44
4.48 0.55
45
1.77 0.34
48
1.54 0.67
49
1.82 0.40
40
1.01 0.62
41
2.32 0.61
47
4.68 0.55
OS-13
7.34 0.25
33
0.73 0.70
32
0.60 0.64 33
0.73 0.70
32
0.60 0.79
35
1.06 0.64
22A
0.89 0.67
18A
0.35 0.78
43
0.53 0.59
39
4.70 0.44
51
0.16 0.25
52
0.28 0.68
35
36
40
37 4138
48
44
43
45
52
47
48
49
39
EXISTING LIND FILING 1
POND 100
POND 200
EX PROPERTY
BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY
BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
OS-13
51
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
FUTURE 10' REGIONAL TRAIL DITCH CROSSING BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
PROP LIMITS OF DEVELOPMENT
NOTES:
1.PROPOSED ELEVATIONS SHOWN ARE RELATIVE TO A DATUM OF 5000 FEET, AND ARE BASED ON THE
BENCHMARKS DESCRIBED ON SHEET C-001.
2.THE DRAINAGE BASINS OS-9, 24-31, 34-49, AND 51-52 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
THE EXISTING DETENTION POND 100. DRAINAGE BASINS OS-5, OS-6, OS-7, OS-8, OS-13, 7-23, AND
32-33 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO PROPOSED POND 200. DRAINAGE BASINS OS1,
OS-2, OS-3, OS-4, OS-10, OS-11, 1-6, AND 50 SHOWN IN THIS EXHIBIT WILL BE CONVEYED TO
PROPOSED POND 300. A SMALL PORTION OF DRAINAGE BASIN OS-1 SHEET FLOWS INTO THE NO. 8
IRRIGATION DITCH, AS HISTORICALLY OCCURS. THE NORTHWEST PORTION OF BASIN 39 FLOWS TO A
HEADWALL AND PIPE W/ ORIFICE CONTROL, AND THEN INTO THE NUMBER 8 DITCH, WHILE THE
SOUTHERN PORTION OF BASIN 39 FLOWS SOUTH AND COMBINES WITH BASIN 49 FLOW, BEFORE
ENTERING EXISTING POND 100. BASIN 0S-12 FLOWS OVERLAND AND INTO THE NO. 8 DITCH.
3.PLEASE REFER TO THE SWMM AND RATIONAL METHOD CALCULATIONS WITHIN THE DRAINAGE
REPORT FOR BASIN FLOW CALCULATIONS, POND SIZING, AND STREET CAPACITY CALCULATIONS.
4.12" OF CDOT CLASS 'A' BEDDING MATERIAL SHALL BE PLACED UNDER ALL RIPRAP SHOWN.
5.RUNOFF FROM THE SITE WILL DRAIN TO LOW POINTS AND PASS THROUGH CURB CUTS, SIDEWALK
CHASES, AND SWALES BEFORE ENTERING STORM INLETS AND PIPES, WHICH ULTIMATELY
DISCHARGE TO THE EXISTING DETENTION POND 100 AND PROPOSED PONDS 200 AND 300.
6. RIPRAP AND GRASS LINED DRAINAGE CHANNELS WILL ENHANCE EROSION CONTROL WITHIN THE
SITE LIMITS. SITE BMP'S WILL BE IMPLEMENTED DURING CONSTRUCTION TO REDUCE SEDIMENT
TRANSPORT OFFSITE AS SHOWN IN THE EROSION CONTROL PLAN.
7.ALL PROPOSED STORM DRAINAGE PIPES AND STRUCTURES OUTSIDE OF CITY RIGHT OF WAY WILL BE
PRIVATELY OWNED AND MAINTAINED BY THE OWNER (SONDERS EAST). ALL EXISTING AND
PROPOSED STORM SEWER WITHIN PUBLIC ROW, WILL BE OWNED AND MAINTAINED BY THE CITY OF
FORT COLLINS.
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
OV
E
R
A
L
L
G
R
A
D
I
N
G
P
L
A
N
&
D
R
A
I
N
A
G
E
E
X
H
I
B
I
T
(
S
E
)
C-036
36 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'KEY MAP - 1" = 1000'
MATCH LINE
SEE SHEET C-018
LEGEND
EXISTING CONTOURS
NEW INTERMEDIATE CONTOURS64
65 NEW INDEX CONTOURS
PROPOSED FLOWLINE
EX RIGHT-OF-WAY/ PROPERTY BOUNDARY
PROPOSED DRAINAGE BASIN BOUNDARY
LINE
PROPOSED STORM PIPE
EXISTING STORM PIPE & MANHOLE
RD
PROPOSED ROOF DRAIN AND STORM PIPE
PROPOSED DRAINAGE BASIN ID
ACRES / 'C' VALUE
PROPOSED DRAINAGE DESIGN POINT
DRAINAGE FLOW DIRECTION
DRAINAGE SWALE
1
0.60 0.25
FOR THE MARKING OF UNDERGROUND
BEFORE YOU DIG, GRADE, OR EXCAVATE
CALL 2 BUSINESS DAYS IN ADVANCE
CENTER OF COLORADO
CALL UTILITY NOTIFICATION
1-800-922-1987
MEMBER UTILITIES.
MAT
C
H
L
I
N
E
SEE
S
H
E
E
T
C
-
0
2
1
036
035
034
PROPOSED LID SUMMARY TABLE:
VOLUME
PROVIDED
100-YR
DESCPOND WSEL.
(AC-FT)(FT)
VOLUME
REQUIRED
(AC-FT)
POND
OUTFLOW
(CFS)
OS-1 OS-2
50
2
OS-3
5
6
4
3
OS-4
OS-12
OS-13
12
11
10 9
8
7
OS-5 OS-6 OS-7 OS-8 OS-9
26
20
13
14
15
16
17 21
22
25
23
24
28 30
27
29 34
LIND
18
19
49
47
44
48
45
41
38
46
39
3736
35
31
3233
40
42
43
18A
22A
1
S-02
S-03
S-01
POND-300
OS-10
ST-320B
ST-321A
ST-320A
P-320
P-321
J123
ST-321B
ST-207D
ST-207C
P-205
P-207
P-208
P-205C
P-205D
P-203
P-201
P-200
P-202C
P-202F
P-202E
ST-202G
ST-202H
ST-202J ST-1313
P-1310
P-135
P-137
P-134
ST-133F
ST-134A
ST-133G
ST-133E
P-133E
P-133B
ST-131G
ST-150A
ST-131D
ST-131C
P-131A
ST-141
J97 ST-112B
ST-112
P-111
P-133B
ST-126
P-125
ST-126
OF1
OF3
OF4
OF2LIND-POND
POND-200
AS
P
E
N
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
SW
M
M
E
X
H
I
B
I
T
C-050
50 84
AUGUST 7, 2024
105001
JYM
JYM
JRG
LEGEND
PIPE CONVEYANCE LINK WITH INLET
STREET CONVEYANCE LINK WITH JUNCTION
BASIN BOUNDARY
PROPOSED DRAINAGE BASIN SUMMARY TABLE:
25
OF3
P-205C
ST-205C
POND OUTFALL
VOLUME
REQUIRED
100-YR
DESCPOND WSEL.
(AC-FT)(FT)
VOLUME
PROVIDED
(AC-FT)
PROPOSED DRAINAGE SUMMARY TABLE
S S S
E
GG
EE
EE
E
EE
EE
EE
EE
EE
GG
G
G
GG
G
G
GG
G
GG
EE
EE
EE
EE
E
GG
G
G
G
G
G
G
G GGGEEEE EE
G GEGGGGEEEE
G GEEGG G G G G G GEEEEEEE E EE EE EE EE
EE
G GG GG GG G
G
G
EE EE EE EEGGGGGGG G
G
G
EE
G
E
GG
EE
EE
G
G
G
G
GG
EE
GG
GG
GG
GG
G
G
G
EE
E
E
EE
E
EE
EE
E
G
GG
EE
GG
GG
G
G
G
G
G
GG
GG
G
E
EE
E
E
EE
EE EE
EE
E
GG GG GG GG
GGG
E EE E E EE
EE E
E
E
EE
E
E
EE
EE
EE
GG
GG
GG
GG
GG
GG
EE
E
G
G
G
GG
G
GG
GG
G
G
G
G
G
GG
G
EE
E
EE
EE
EE
EE
EE
EE
EE
EE EE
EEEEEE EEE
EE EE EE
EE EE
G G G GG G
GGGGGG
G GG
GG G
EE EE
EE EE EE EE E
EE EE
EE EE
G GG
G G G GG G G GG
GG GG
EE EE GGGGEEG
EEG
EE GG
EE EE EEGGGG G
GG G
EE EEGG G
G
G
EE GG
EEEGG G
GGG
EE
EE
E
EE
G
G
G
GG
G G
G
G
EE
G
EE
EE
EE
EE
EE
GG
GG
GG
GG
G
G
E
EE
EE
GG
G
G
G
G
E
EE
EE
GG
GG
GG
G
E
EE
EE
G
G G
G
E
EE
G
G
G
EE
EE
EE
EE
GG
G
G
G G G
G
GGGEEEEG
G
G
EE
S
W
S
W
G
G
G
S
W
S
W
S
W
S
W
S
W
S W SW
W
SW
G
E
EG
EG
EG
E
G
S S S S S S
S S S S S
SSSSSS
SSSSSS S S S
S S S S S S S S S
S
S S S
S S S S S S S S S
S S S S S S S S
S S S
S
S SS
S S S
S S S S S S
S S S S S S S S
S S
S
SSSSSSS
S S S S S S
E
G G G
E
G
EG
EG
EG
EG
SSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S S S
S
S
S
S
S
S
S S
S S
S S S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S S
S
S
S
WW W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S S S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSS
SS
S
S
W W W
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
WWWWWWWWW
W W W W
W W W
W W W W W W
W W W W
W W W
W
W W W WWW
W
W W
W
W
W
W W
W W W W W
S
W
W
W
W W
WWW
W
W
W
W W W W W W W W W W W W W W W W W
W
W
W WW W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W W W W W W W W W W
W
W
W
W W W
WWWWWWWW
W
W
W
S
W
W W
W W
W
W
S
W
S
WS
W
S
S
W
W
W
W
W
W
S
S
S
S
W
W
S
S
S
S
S
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
W
GESW EE E E EE EWWWWWWWSSSSSSGGGGGGG
E EE EE EE EEWWWWWWWW WSSSSSSSSSGGGGGGGG
G
G G
G G
S S
S
E
E E
EE
W W
W W
W
W
S S S
SG
S
S
W
W
W
W
F
F
F
F
W
FFW
WF
WF
SS
S
S
W
W W W W
W
W
S
W
W W
W
W
W
W
W
W
WDP
DP
WW
DP
DP
DP DP
DP
EE EE
SSS
SSSS
WWW
EEEGGG
EE
W W
W W
S S
S
S
S
EE GG
G G
G G G G
W W W W
S
G
S S SGGG S S SGGG
W SW S SWW S
E E E
W
DPE E E
W
DPE
DP
WW W
EEE DP
WW W
EEE DP
WW W
EEE
GS
S
G SSGSGSSGS
S WSWWSSWWSSWSWWS
G
G
EG EG EG E G EG EG EG EG E G
E G EG E G E G EG E G EG E G E G
EG E G EG EG EG E G EG E GEGEG
EG EG EG EG EG EG EG EGEGEG E G
G
EG E G EG EG EG EG E G EGEGEG
E
G
E
G
E
G
EG E EG G
EG EG EG EG EG EG EGEGEG EG EG EG
EG
W SW
SW
WS W W W W W W W WSSSSSSS S S W
WSSWWSSSSSSSSWWWWWWWW
W S
WSWSSW
W
S S S S SWWWW W
SW SW SW S S S
W W W
W S W S
W
EG EG EG
E
E
E
E
G
G
G
G
G E GE GE G E
E G
E G
W W S W
W
W
W
W
W
S
EGEGEG
EG
EGEG
EG EG EG GE GE
GE
G
WWWW
WW
W W
S
W
W
W
W
W
EG
G
E
G
E
EG
EG
EG
G E
G
E
GE
EG
S S S S SWWWW
G
S
W
E
S
E
E
G
G G
G
E G
G
G
E
E
E
E
G
E
1
2
3
4
BLK1
BLK1
BLK1
5
6
7
8 9 10 11
BLK2
5 6
BLK3
BLK4
BLK5 BLK6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
7 8 9 10
14 13 12 11
1 2 3 4
8 7 6 5
1 2 3
6 5 4
7 8 9 10
14 13 12 11
13
12
14 15 16 17 18
BLK1
BLK1
BLK1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
36 35 34
33
1 2 3 4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19 2021
BLK
4
BLK7BLK5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK10 BLK10
BLK
11
BLK12
BLK14
1
2
3
4
5
6
7
8
9
BLK15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK15
BLK15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK15
BLK
15
BLK16
BLK17
BLK19
BLK18
BLK21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4 5 6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK11
BLK14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK12
BLK12
BLK12
8 7
1 2
4 3
1 2
4 3
5 6
16 15
BLK2 BLK3
BLK1
BLK
20
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1 2 3 4
7 6 5
8
11
9
10
BUILDING A3 STORY18 UNIT
BUILDING B3 STORY18 UNIT
BLK
8BLK8
24
12 13
14
212223
BLK9 BLK9
1021
13
22232425
BLK10 BLK10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D3 STORY18 UNIT
BUILDING A3 STORY18 UNIT
VTC
SF
W
IP
IP
GB
MU
CWO
RS
GF
RR
NOTES: .
1.PERIMETER SILT FENCE SHALL BE INSTALLED ALONG PROPERTY
BOUNDARY, AND IS SHOWN OFFSET FROM PROPERTY BOUNDARY
ON THIS PLAN FOR CLARITY.
·TOTAL PERIMETER SILT FENCE AROUND SITE = 10,566 LF.
2.ALL DISTURBED AREAS ARE TO BE SEEDED AND MULCHED.
3.STOCK PILES SHALL NOT TO EXCEED 10' IN HEIGHT.
4.ALL OFFSITE AREAS DISTURBED DURING CONSTRUCTION ARE TO
BE RE-VEGETATED AND RETURNED TO HISTORIC CONDITION.
STRAW WATTLES OR GRAVEL INLET FILTERS MAY BE INSTALLED
(IF NECESSARY AND AS REQUIRED) ON EXISTING,
OFFSITE/DOWNSTREAM INLETS.
5.VEHICLE TRACKING PAD(S) LOCATIONS SHALL BE DETERMINED
BY THE CONTRACTOR, PRIOR TO CONSTRUCTION, AND SHALL BE
INSTALLED ACCORDINGLY.
6.SEE SHEET C-018 & C-019 FOR EROSION CONTROL NOTES AND
DETAILS. SYMBOLS SHOWN IN THIS PLAN ARE NOT TO SCALE.
7.PHASED EROSION CONTROL SEQUENCING AND PLANS WILL BE
SHOWN AND PROVIDED DURING FINAL DESIGN. SILT FENCE OR
STRAW WATTLES SHALL BE INSTALLED AROUND BLOCKS, AFTER
UTILITY AND STREET CONSTRUCTION AND GRADING IS
COMPLETE. THE EROSION MEASURES WILL BE INSTALLED WHERE
CONSTRUCTION WILL NOT BE DEVELOPED FOR AN EXTENDED
PERIOD OF TIME.
8.THE OFFSITE LIMITS OF DEVELOPMENT (EAST SIDE OF NEW DITCH
RELOCATION, SHALL HAVE DIRT BERM PLACED ALONG LIMITS OF
DEVELOPMENT LINE IN-LIEU-OF SILT FENCE.
9.INSTALL NORTH AMERICAN GREEN EROSION CONTROL FABRIC TO
4:1 SLOPES ADJACENT TO THE NO. 8 DITCH.
LEGEND .
INSTALL VEHICLE TRACKING PAD
INSTALL SILT FENCE
INSTALL CONCRETE WASHOUT
HAY OR STRAW DRY MULCH (1-5%)
INSTALL 12" STRAW WATTLE CHECK DAM
LIMITS OF DISTURBANCE
INSTALL CURB INLET GRAVEL FILTER
INSTALL AREA INLET GRAVEL FILTER
PROPOSED DIRECTION OF SURFACE FLOW
INSTALL ROCK SOCK FILTER
INSTALL GRAVEL CURB CHECK BAG
INSTALL NORTH AMERICAN GREEN C350
PROPOSED MAJOR CONTOUR - 5 FT INTERVAL
PROPOSED MINOR CONTOUR - 1 FT INTERVAL
EXISTING MAJOR CONTOUR - 5 FT INTERVAL
EXISTING MINOR CONTOUR - 1 FT INTERVAL
EXISTING DIRECTION OF SURFACE FLOW
INSTALL RIPRAP PROTECTION (TYPE M D =12")
65
64
60
65
59
6162636466
6
7
6
8
6
9
60
6
0
6
5
59
5
9
61
6
1
6
2
6
2
6
3
6
3
6
4
6
6
6
7
62
63
6
5
6
2
6
3
6
4
65
64
62
63
60 61
62
6
3
60
56
57
58
59
61
62
6
5
70
6
2
6
3
6
4
66
67
68
69
71
6
5
63
64
6
6
6
7
68
60
61
62
6
3
60
61
62
63
65
7
0
64
66
67
6
8
6
9
60
59
61
62
63
65
61
62
63
64
65
7
0
66
67
6
8
6
9
70
66676869
65
63
64
66
6
0
65
65
61
6
1
62
6
2
63
6
3
64
64
63
64
40
45
50
50
39
41
42
4344
46
46
47
47
48
49
49
50
5
0
5
0
55
60
464
7
4
8
4
9
49
4
9
51
52
53545657585961
40
45
45
45
50
55
60
65
41
42
42
42
43
43
43
44
44
44
46
46
46
47
47
47
48
48
48
49
49
49
51
52
53
54
56
57
58
59
61
62
63
64
66
67
68
5
5
5
5
6
0
6
0
6
5
7
0
5
4
5
4
5
6
56
5
7
57
5
8
5
8
59
59
6
1
61
6
1
6
1
6
2
6
2
6
3
6
3
6
4
6
6
6
7
6
8
6
9
6
5
65
7
0
7
0
64
6
4
6
6
6
6
6
7
6
7
6
8
6
8
6
9
6
9
7
1
7
1
7
1
7
2
7
2
7
3
50
48
4
5
7
2
72
73
71
70
69
69
65666768
64
7
0
7
0
70
70
70
7
0
63
64
64
65
65
66
63
70
69
6
0
5
2
6
0
5
5
55
6
0
5
2
6
5
6
1
6
7
5
5
5
0
5
0
45
5053
49
48 47 46 45
4945
42
61
6
2
62
6
1
6
3
6
3
7
0
50
50
45
42
42
45
50
52
52
59
59
51
50
51
55
59
60
67
41
49
42
49
42
50
55
60
40
63
64
65
66
67
68
69
70
1
2
3
4
BLK
1
BLK
1
BLK
1
5
6
7
8 9 10 11
BLK
2
5 6
BLK
3
BLK
4
BLK
5 BLK
6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
1 2 3 4
8 7 6 5
1 2 3
6 5 4
13
12
14 15 16 17 18
BLK
1
BLK
1
BLK
1
19
20
21
22
23
24
25
26
27
28
29
1 2 3 4
5
6
7
8
9
10
11
16
17
18
19 2021
BLK
4
8 7
1 2
4 3
1 2
4 3
BLK
2 BLK
3
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
NATURE PARK WAY
N
A
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
MOORLAND WAY
PARKLAND WAY
AMBLE LANEAMBLE LANE
S
T
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
IP
VTC
IP IP
25' DITCH & DITCH
ACCESS EASEMENT
REC NO. 200030157848
(TO BE VACATED BY
CURRENT PLAT)
PROP ROW
MATCH LINE SEE SHEET C-016
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
PROP ROW
PROP DITCH EASEMENT
PROP DITCH EASEMENT
PROP TEMPORARY CONSTRUCTION EASEMENT
PROP TEMPORARY CONSTRUCTION EASEMENT
PROP DITCH EASEMENT
PROP DRAINAGE EASEMENT
PROP DRAINAGE EASEMENT
PROP IRRIGATION EASEMENT
PROP DRAINAGE EASEMENT
PROP TOP (TOP OF BANK) OF NO. 8 DITCH
PROP BOTTOM (TOE OF SLOPE) OF NO. 8 DITCH
50'
128
'
PROP TOP (TOP OF BANK) OF NO. 8 DITCH
PROP BOTTOM (TOE OF SLOPE) OF NO. 8 DITCH
PROP BAKER LATERAL IRRIGATION EASEMENT
25'
PROP BAKER LATERAL IRRIGATION EASEMENT
25'
25' DITCH & DITCH
ACCESS EASEMENT
REC NO. 200030157848
(TO BE VACATED BY
CURRENT PLAT)
PROP CONC DROP STRUCTURE
PROP CONC DROP STRUCTURE
EX ROW
EX ROW
EX ROW
FUT ROW
EX PROPERTY
BOUNDARY
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF
DEVELOPMENT
PROP LIMITS OF
DEVELOPMENT
PROP EDGE OF
NEW ASPHALT
MATCH EXISTING
EX EDGE OF
ASPHALT
PROP EDGE OF
NEW ASPHALT
EX EDGE OF
ASPHALT
IP
RS
RS
RS
RS
RS
RS
RS
RS
RS
W
W
W
W
RR
RR
RR
IPIP
GB GB
GB GB
GBGB
GB
GB
GB
GB
GB GB
GB
GB
GB
GB
G
B
G
B
POND 300
IP
REFER TO NOTE 9 THIS SHEET
REFER TO NOTE 9 THIS SHEET
REFER TO NOTE 9 THIS SHEET
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
PROP 2'
ACCESS
ESMT.
PROP 2'
ACCESS
ESMT.
10'
ACTIVE
MODES
PATH
10'
ACTIVE
MODES
PATH
10'
ACTIVE
MODES
PATH
24'x50'
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
N
O
R
T
H
)
C-015
15 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'
017
016
015
KEY MAP - 1" = 1000'
MATCH LINE
SEE SHEET C-016
Street Cut Note
TOTAL
ONSITE AREA
DISTURBED
(SF)
5,641,981
TOTAL
OFFSITE AREA
DISTURBED
(SF)
3,744,027
1.PROJECT WILL BE CONSTRUCTED IN MULTIPLE PHASES.
2.STORAGE/STAGING AREAS SHALL BE WITHIN THE AREA OF DISTURBANCE/ LIMITS OF
DEVELOPMENT.
3.NO HAUL ROADS OFFSITE ARE EXPECTED.
4.HEAVY CONSTRUCTION TRAFFIC TO BE ROUTED IN COORDINATION WITH THE SONDERS EAST
PROJECT MANAGER, PRIOR TO START OF CONSTRUCTION.
5.GROUNDWATER DEPTHS ARE BASED ON BORING INFORMATION COMPLETED FOR SONDERS EAST,
BY CTL THOMPSON, PROJECT NO. FC08010.003-115.
6.SITE SLOPES SHALL BE NO GREATER THAN 4:1.
7.NO RIPARIAN OR SENSITIVE AREAS ARE IDENTIFIED WITH THIS PROJECT.
DISTURBANCE
AT ANY
ONE TIME
(%)
100
EXISTING
VEGETATION
DENSITY
(%)
VARIES
60-85%
EXISTING
SOIL TYPE
TYPE A
SOIL
GROUND
WATER
LEVEL
(FT)
16' to 29'
MATERIAL
CUT/FILL
(CF)
38,329,443
PROJECT DETAILS
S S S
E
GG
EE
EE
E
EE
EE
EE
EE
EE
GG
G
G
GG
G
G
GG
G
GG
EE
EE
EE
EE
E
GG
G
G
G
G
G
G
G GGGEEEE EE
G GEGGGGEEEE
G GEEGG G G G G G GEEEEEEE E EE EE EE EE
EE
G GG GG GG G
G
G
EE EE EE EEGGGGGGG G
G
G
EE
G
E
GG
EE
EE
G
G
G
G
GG
EE
GG
GG
GG
GG
G
G
G
EE
E
E
EE
E
EE
EE
E
G
GG
EE
GG
GG
G
G
G
G
G
GG
GG
G
E
EE
E
E
EE
EE EE
EE
E
GG GG GG GG
GGG
E EE E E EE
EE E
E
E
EE
E
E
EE
EE
EE
GG
GG
GG
GG
GG
GG
EE
E
G
G
G
GG
G
GG
GG
G
G
G
G
G
GG
G
EE
E
EE
EE
EE
EE
EE
EE
EE
EE EE
EEEEEE EEE
EE EE EE
EE EE
G G G GG G
GGGGGG
G GG
GG G
EE EE
EE EE EE EE E
EE EE
EE EE
G GG
G G G GG G G GG
GG GG
EE EE GGGGEEG
EEG
EE GG
EE EE EEGGGG G
GG G
EE EEGG G
G
G
EE GG
EEEGG G
GGG
EE
EE
E
EE
G
G
G
GG
G G
G
G
EE
G
EE
EE
EE
EE
EE
GG
GG
GG
GG
G
G
E
EE
EE
GG
G
G
G
G
E
EE
EE
GG
GG
GG
G
E
EE
EE
G
G G
G
E
EE
G
G
G
EE
EE
EE
EE
GG
G
G
G G G
G
GGGEEEEG
G
G
EE
S
W
S
W
G
G
G
S
W
S
W
S
W
S
W
S
W
S W SW
W
SW
G
E
EG
EG
EG
E
G
S S S S S S
S S S S S
SSSSSS
SSSSSS S S S
S S S S S S S S S
S
S S S
S S S S S S S S S
S S S S S S S S
S S S
S
S SS
S S S
S S S S S S
S S S S S S S S
S S
S
SSSSSSS
S S S S S S
E
G G G
E
G
EG
EG
EG
EG
SSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S S S
S
S
S
S
S
S
S S
S S
S S S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S S
S
S
S
WW W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S S S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSS
SS
S
S
W W W
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
WWWWWWWWW
W W W W
W W W
W W W W W W
W W W W
W W W
W
W W W WWW
W
W W
W
W
W
W W
W W W W W
S
W
W
W
W W
WWW
W
W
W
W W W W W W W W W W W W W W W W W
W
W
W WW W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W W W W W W W W W W
W
W
W
W W W
WWWWWWWW
W
W
W
S
W
W W
W W
W
W
S
W
S
WS
W
S
S
W
W
W
W
W
W
S
S
S
S
W
W
S
S
S
S
S
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
W
GESW EE E E EE EWWWWWWWSSSSSSGGGGGGG
E EE EE EE EEWWWWWWWW WSSSSSSSSSGGGGGGGG
G
G G
G G
S S
S
E
E E
EE
W W
W W
W
W
S S S
SG
S
S
W
W
W
W
F
F
F
F
W
FFW
WF
WF
SS
S
S
W
W W W W
W
W
S
W
W W
W
W
W
W
W
W
WDP
DP
WW
DP
DP
DP DP
DP
EE EE
SSS
SSSS
WWW
EEEGGG
EE
W W
W W
S S
S
S
S
EE GG
G G
G G G G
W W W W
S
G
S S SGGG S S SGGG
W SW S SWW S
E E E
W
DPE E E
W
DPE
DP
WW W
EEE DP
WW W
EEE DP
WW W
EEE
GS
S
G SSGSGSSGS
S WSWWSSWWSSWSWWS
G
G
EG EG EG E G EG EG EG EG E G
E G EG E G E G EG E G EG E G E G
EG E G EG EG EG E G EG E GEGEG
EG EG EG EG EG EG EG EGEGEG E G
G
EG E G EG EG EG EG E G EGEGEG
E
G
E
G
E
G
EG E EG G
EG EG EG EG EG EG EGEGEG EG EG EG
EG
W SW
SW
WS W W W W W W W WSSSSSSS S S W
WSSWWSSSSSSSSWWWWWWWW
W S
WSWSSW
W
S S S S SWWWW W
SW SW SW S S S
W W W
W S W S
W
EG EG EG
E
E
E
E
G
G
G
G
G E GE GE G E
E G
E G
W W S W
W
W
W
W
W
S
EGEGEG
EG
EGEG
EG EG EG GE GE
GE
G
WWWW
WW
W W
S
W
W
W
W
W
EG
G
E
G
E
EG
EG
EG
G E
G
E
GE
EG
S S S S SWWWW
G
S
W
E
S
E
E
G
G G
G
E G
G
G
E
E
E
E
G
E
1
2
3
4
BLK1
BLK1
BLK1
5
6
7
8 9 10 11
BLK2
5 6
BLK3
BLK4
BLK5 BLK6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
7 8 9 10
14 13 12 11
1 2 3 4
8 7 6 5
1 2 3
6 5 4
7 8 9 10
14 13 12 11
13
12
14 15 16 17 18
BLK1
BLK1
BLK1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
36 35 34
33
1 2 3 4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19 2021
BLK
4
BLK7BLK5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK10 BLK10
BLK
11
BLK12
BLK14
1
2
3
4
5
6
7
8
9
BLK15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK15
BLK15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK15
BLK
15
BLK16
BLK17
BLK19
BLK18
BLK21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4 5 6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK11
BLK14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK12
BLK12
BLK12
8 7
1 2
4 3
1 2
4 3
5 6
16 15
BLK2 BLK3
BLK1
BLK
20
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1 2 3 4
7 6 5
8
11
9
10
BUILDING A3 STORY18 UNIT
BUILDING B3 STORY18 UNIT
BLK
8BLK8
24
12 13
14
212223
BLK9 BLK9
1021
13
22232425
BLK10 BLK10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D3 STORY18 UNIT
BUILDING A3 STORY18 UNIT
VTC
SF
W
IP
IP
GB
MU
CWO
RS
GF
RR
NOTES: .
1.PERIMETER SILT FENCE SHALL BE INSTALLED ALONG PROPERTY
BOUNDARY, AND IS SHOWN OFFSET FROM PROPERTY BOUNDARY
ON THIS PLAN FOR CLARITY.
·TOTAL PERIMETER SILT FENCE AROUND SITE = 10,566 LF.
2.ALL DISTURBED AREAS ARE TO BE SEEDED AND MULCHED.
3.STOCK PILES SHALL NOT TO EXCEED 10' IN HEIGHT.
4.ALL OFFSITE AREAS DISTURBED DURING CONSTRUCTION ARE TO
BE RE-VEGETATED AND RETURNED TO HISTORIC CONDITION.
STRAW WATTLES OR GRAVEL INLET FILTERS MAY BE INSTALLED
(IF NECESSARY AND AS REQUIRED) ON EXISTING,
OFFSITE/DOWNSTREAM INLETS.
5.VEHICLE TRACKING PAD(S) LOCATIONS SHALL BE DETERMINED
BY THE CONTRACTOR, PRIOR TO CONSTRUCTION, AND SHALL BE
INSTALLED ACCORDINGLY.
6.SEE SHEET C-018 & C-019 FOR EROSION CONTROL NOTES AND
DETAILS. SYMBOLS SHOWN IN THIS PLAN ARE NOT TO SCALE.
7.PHASED EROSION CONTROL SEQUENCING AND PLANS WILL BE
SHOWN AND PROVIDED DURING FINAL DESIGN. SILT FENCE OR
STRAW WATTLES SHALL BE INSTALLED AROUND BLOCKS, AFTER
UTILITY AND STREET CONSTRUCTION AND GRADING IS
COMPLETE. THE EROSION MEASURES WILL BE INSTALLED WHERE
CONSTRUCTION WILL NOT BE DEVELOPED FOR AN EXTENDED
PERIOD OF TIME.
8.THE OFFSITE LIMITS OF DEVELOPMENT (EAST SIDE OF NEW DITCH
RELOCATION, SHALL HAVE DIRT BERM PLACED ALONG LIMITS OF
DEVELOPMENT LINE IN-LIEU-OF SILT FENCE.
9.INSTALL NORTH AMERICAN GREEN EROSION CONTROL FABRIC TO
4:1 SLOPES ADJACENT TO THE NO. 8 DITCH.
LEGEND .
INSTALL VEHICLE TRACKING PAD
INSTALL SILT FENCE
INSTALL CONCRETE WASHOUT
HAY OR STRAW DRY MULCH (1-5%)
INSTALL 12" STRAW WATTLE CHECK DAM
LIMITS OF DISTURBANCE
INSTALL CURB INLET GRAVEL FILTER
INSTALL AREA INLET GRAVEL FILTER
PROPOSED DIRECTION OF SURFACE FLOW
INSTALL ROCK SOCK FILTER
INSTALL GRAVEL CURB CHECK BAG
INSTALL NORTH AMERICAN GREEN C350
PROPOSED MAJOR CONTOUR - 5 FT INTERVAL
PROPOSED MINOR CONTOUR - 1 FT INTERVAL
EXISTING MAJOR CONTOUR - 5 FT INTERVAL
EXISTING MINOR CONTOUR - 1 FT INTERVAL
EXISTING DIRECTION OF SURFACE FLOW
INSTALL RIPRAP PROTECTION (TYPE M D =12")
65
64
5
0
55
4
7
4
8
4
9
5
1
5
2
52
5
2
5
3
53
53
5
3
53
53
5
3
54
56
57
58
59
6
16263
64
60
58
5
8
58
59
61
62
63
55
60
6
0
5657
5
7
58
5
8
59
5
9
61
6
1
55
6
0
6
5
5
2
52
53
545657
5
8
5
9
6
1
6
2
6
3
6
4
55
54
565758
5560
53
5456575859
55
55
54
54
56
56
57
58
5
5
5
4
54
5
6
50
46
47
48
49
51
52
53
54
4
5
50
4
4
46
47
48
49
51
52
45
50
43
44
46
47
48
49
51
52
53
4
0
4
5
5
0
3
7
3
8
3
9
4
1
4
2
4
3
4
4
4
6
4
7
4
8
4
9
5
1
45
43
44
46
6
0
6
1
55
54
56
57
58
60
65
6162
63
64
66
67
68
69
6
0
6
5
7
0
59
6
1
6
2
6
3
6
4
6
6
6
7
6
8
6
9
55
60
56
57
58
59
61
62
63
64
5560565758596162
55
60
545657585961
5
5
60
5
4
5
6
5
7
5859
60
65
58
59
61
62
63
64
66
67
68
69
55
53
5
4
56575859
55
53
54
565758
55
60
65
56
57
58
59
61
62
63
64
55
52
53
54
56
57
50
48
49
51
52
5354
50
4849
515253
45
50
44
46
474849
51
52
53
54
45
4344
46
45
42
43
44
50
46
47
48
49
5
1
5
2
45
50
44
46
47
48
49
51
5
2
5
3
5
4
50
46
47
48
49
51
52
53
40
45
50
37
38
39
41
42
43
44
46
47
48
49
51
52
53
50
47
48
49
51
45
50
41
42
43
44
46
47
48
49
40
45
37
38
39
41
4
2
43
44
46
47
48
45
44
36
37
38
39
5
2
5
1
5
0
4
9
4
8
47
4
6
45
4
4
4
3
4
2
4
1
41
42
42
4
1
40
39
38
37
42
37
4
0
3
9
4
0
4
1
4
2
4
1
4
2
4
2
3
8
3
7
5
3
42
41
42
3840
4
5
4
0
3
9
4
5
5
0
55
43
41
4
2
4
2
4
1
4
0
4
2
4
2
4
1
69
68
6
9
7
0
70
7
0
66
67
68
69
70
65
64
63
63 60 55
53
53
54
54
53
52 51
5
3
53
5
4
5
4
4
7
45
44
43
46
5
0
5
3
5
0
4
5
53
5857
64
65
4
3
5554
53
54
54
3
7
3
8
3
9
40
42
41
40
40
60
61
62
4
4
43
4
2
4
1
4
0
39
38
37
DP
DP
DP
DP
DP DP
DP
DP DP
DP DP DP DP
DP
DP
DP
DP DP
DP
DP DP
DP DP DP
BLK
5 BLK
6
BLK
7
7 8 9 10
14 13 12 11
8 7 6 5
6 5 4
7 8
9
10
14 13
12
11
27
28
29
30
31
32
36
35
34
33
10
11
12
13
14
15
16
17
BLK
4
BLK
7BLK
5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK
10
BLK
10
BLK
11
BLK
12
BLK
14
1
2
3
4
5
6
7
8
9
BLK
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
BLK
16
BLK
17
13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4
5
6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK
11
BLK
14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK
12
BLK
12
BLK
12
4 3
5 6
16 15
BLK
1
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BRIGHTWATER DRIVE
CLIPPER WAY
WEL
L
N
E
S
S
R
O
A
D
H
I
G
H
M
E
A
D
O
W
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
STA
R
D
U
S
T
W
A
Y
TR
A
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
H
I
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
WANDER T
R
A
I
L
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
MORNING STAR DRIVE
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
1 2 3 4
7 6 5
8
11
9
10
BUILDING A
3 STORY
18 UNIT
BUILDING B
3 STORY
18 UNIT
BLK
8
BLK
8
24
12 13
14
212223
BLK
9
BLK
9
1021
13
22232425
BLK
10
BLK
10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D
3 STORY
18 UNIT
BUILDING A
3 STORY
18 UNIT
WA
T
E
R
S
E
D
G
E
S
E
C
O
N
D
F
I
L
I
N
G
E
X
I
R
R
I
G
A
T
I
O
N
D
I
T
C
H
W
.
P
.
E
L
D
E
R
R
E
S
E
R
V
O
I
R
O
U
T
L
E
T
C
A
N
A
L
TRACT B
LIND PROPERTY
REC. NO.
200030150497
24'x50'
IP
RS
RS
RR
RR
IP IP
IP
IP
IP
RR
IPIP
IPIP
IP
IP
IP
IP
IP
IP
IP
IP IP
IP
IP
IP
IP
IP
IP
RS
RS
RS
RS
RS
GB
GB
GB
GB
W
W
GB
GB
GB
GB
GB
GB GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GBGB
GB
GB
GB
GB
GB
GB
EX PROPERTY
BOUNDARY
25' DITCH & DITCH
ACCESS EASEMENT
REC NO. 200030157848
(TO BE VACTED BY
CURRENT PLAT)
MATCH LINE SEE SHEET C-015
MAT
C
H
L
I
N
E
S
E
E
S
H
E
E
T
C
-
0
1
7
PROP BAKER LATERAL IRRIGATION EASEMENT
PROP LIMITS OF
DEVELOPMENT
PROP LIMITS OF
DEVELOPMENT
EX ROW
PROP ROW
EX ROW
PROP ROW
EX PROPERTY
BOUNDARY
PROP EDGE
OF NEW
ASPHALT
EX EDGE OF
ASPHALT
PROP EDGE OF
NEW ASPHALT
EX EDGE OF
ASPHALT
PROP BAKER LATERAL
IRRIGATION EASEMENT
PROP DRAINAGE EASEMENT
PROP DRAINAGE EASEMENT
EX PROPERTY BOUNDARY
EX PROPERTY BOUNDARY
PROP LIMITS OF
DEVELOPMENT
EX PROPERTY
BOUNDARY
RAIN
GARDEN
POND 200
PROP DRAINAGE EASEMENT
PROP DRAINAGE EASEMENT
FUTURE 10' REGIONAL TRAIL BY OTHERS
PROPOSED 50' TRAIL AND NATURAL AREAS BUFFER EASEMENT
IPIP
RR
IP
VTC
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
S
O
U
T
H
)
C-016
16 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'
017
016
015
KEY MAP - 1" = 1000'Street Cut Note
TOTAL
ONSITE AREA
DISTURBED
(SF)
5,641,981
TOTAL
OFFSITE AREA
DISTURBED
(SF)
3,744,027
1.PROJECT WILL BE CONSTRUCTED IN MULTIPLE PHASES.
2.STORAGE/STAGING AREAS SHALL BE WITHIN THE AREA OF DISTURBANCE/ LIMITS OF
DEVELOPMENT.
3.NO HAUL ROADS OFFSITE ARE EXPECTED.
4.HEAVY CONSTRUCTION TRAFFIC TO BE ROUTED IN COORDINATION WITH THE SONDERS EAST
PROJECT MANAGER, PRIOR TO START OF CONSTRUCTION.
5.GROUNDWATER DEPTHS ARE BASED ON BORING INFORMATION COMPLETED FOR SONDERS EAST,
BY CTL THOMPSON, PROJECT NO. FC08010.003-115.
6.SITE SLOPES SHALL BE NO GREATER THAN 4:1.
7.NO RIPARIAN OR SENSITIVE AREAS ARE IDENTIFIED WITH THIS PROJECT.
DISTURBANCE
AT ANY
ONE TIME
(%)
100
EXISTING
VEGETATION
DENSITY
(%)
VARIES
60-85%
EXISTING
SOIL TYPE
TYPE A
SOIL
GROUND
WATER
LEVEL
(FT)
16' to 29'
MATERIAL
CUT/FILL
(CF)
38,329,443
PROJECT DETAILS
1
2
3
4
BLK1
BLK1
BLK1
5
6
7
8 9 10 11
BLK2
5 6
BLK3
BLK4
BLK5 BLK6
BLK
7
1 2 3 4
8 7 6 5
9 10 11 12
16 15 14 13
7 8 9 10
14 13 12 11
1 2 3 4
8 7 6 5
1 2 3
6 5 4
7 8 9 10
14 13 12 11
13
12
14 15 16 17 18
BLK1
BLK1
BLK1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
36 35 34
33
1 2 3 4
5
6
7
8
9
10
11
12
13
1415
16
17
18
19 2021
BLK
4
BLK7BLK5
1 2 3 4 5 6 7 8 9 10 11
1516171819202526
3 4 5 6 7 8 9
11
12
14
15161718192021
BLK10 BLK10
BLK
11
BLK12
BLK14
1
2
3
4
5
6
7
8
9
BLK15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK15
BLK15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK15
BLK
15
BLK16
BLK17
BLK19
BLK18
BLK21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
1 2 3 4 5 6 7 8 9 10 11
15
12 13 14
22
23242526272829
21
20
35 34
1 2 3 4 5 6 7 8 9
1011121314
1 2 3 4 5 6
7
8
9
10
11
12
14
16
17
18
19
20
22
15161718
19 20 21 22 23 24 25 26 27 28
BLK11
BLK14
27 28 29 30 31 32 33 34
35
36
37
38
39
47 46 45 44 43 42 41 40
BLK12
BLK12
BLK12
8 7
1 2
4 3
1 2
4 3
5 6
16 15
BLK2 BLK3
BLK1
BLK
20
MORNING STAR DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WELL
N
E
S
S
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
HIG
H
M
E
A
D
O
W
R
O
A
D
ST
A
R
D
U
S
T
W
A
Y
TRA
I
L
W
A
Y
R
O
A
D
WALKING STICK WAY
PATHWAY ROAD
PARKLAND ROAD
HI
G
H
M
E
A
D
O
W
R
O
A
D
FIELD POINT WAY
ST
E
R
N
W
H
E
E
L
E
R
DR
I
V
E
MEADOW LARK ROAD
WANDER TRAIL
NATURE PARK WAY
NA
T
U
R
E
P
A
R
K
W
A
Y
GR
E
E
N
S
P
A
C
E
R
O
A
D
GR
E
E
N
S
P
A
C
E
R
O
A
D
GRASSLAND ROAD
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PLAY
P
A
R
K
L
A
N
E
TRAILS CROSSING LANE
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
FA
I
R
W
A
T
E
R
D
R
I
V
E
ST
E
R
N
W
H
E
E
L
E
R
D
R
I
V
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
TU
R
N
B
E
R
R
Y
R
O
A
D
(T
W
O
L
A
N
E
A
R
T
E
R
I
A
L
)
BRIGHTWATER DRIVE
MORNING STAR DRIVE
MOORLAND WAY
PARKLAND WAY
AMBLE LANE
PATHWAY LANE PATHWAY LANEPATHWAY LANE
STE
R
N
W
H
E
E
L
E
R
D
R
I
V
E
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
AMBLE LANE
ST
E
R
N
W
H
E
E
L
E
R
C
O
U
R
T
1 2 3 4
7 6 5
8
11
9
10
BUILDING A3 STORY18 UNIT
BUILDING B3 STORY18 UNIT
BLK
8BLK8
24
12 13
14
212223
BLK9 BLK9
1021
13
22232425
BLK10 BLK10
BLK
11
30313233
16
17
18
19
23242526
21
15
13
BUILDING D3 STORY18 UNIT
BUILDING A3 STORY18 UNIT
S S S
E
GG
EE
EE
E
EE
EE
EE
EE
EE
GG
G
G
GG
G
G
GG
G
GG
EE
EE
EE
EE
E
GG
G
G
G
G
G
G
G GGGEEEE EE
G GEGGGGEEEE
G GEEGG G G G G G GEEEEEEE E EE EE EE EE
EE
G GG GG GG G
G
G
EE EE EE EEGGGGGGG G
G
G
EE
G
E
GG
EE
EE
G
G
G
G
GG
EE
GG
GG
GG
GG
G
G
G
EE
E
E
EE
E
EE
EE
E
G
GG
EE
GG
GG
G
G
G
G
G
GG
GG
G
E
EE
E
E
EE
EE EE
EE
E
GG GG GG GG
GGG
E EE E E EE
EE E
E
E
EE
E
E
EE
EE
EE
GG
GG
GG
GG
GG
GG
EE
E
G
G
G
GG
G
GG
GG
G
G
G
G
G
GG
G
EE
E
EE
EE
EE
EE
EE
EE
EE
EE EE
EEEEEE EEE
EE EE EE
EE EE
G G G GG G
GGGGGG
G GG
GG G
EE EE
EE EE EE EE E
EE EE
EE EE
G GG
G G G GG G G GG
GG GG
EE EE GGGGEEG
EEG
EE GG
EE EE EEGGGG G
GG G
EE EEGG G
G
G
EE GG
EEEGG G
GGG
EE
EE
E
EE
G
G
G
GG
G G
G
G
EE
G
EE
EE
EE
EE
EE
GG
GG
GG
GG
G
G
E
EE
EE
GG
G
G
G
G
E
EE
EE
GG
GG
GG
G
E
EE
EE
G
G G
G
E
EE
G
G
G
EE
EE
EE
EE
GG
G
G
G G G
G
GGGEEEEG
G
G
EE
S
W
S
W
G
G
G
S
W
S
W
S
W
S
W
S
W
S W SW
W
SW
G
E
EG
EG
EG
E
G
S S S S S S
S S S S S
SSSSSS
SSSSSS S S S
S S S S S S S S S
S
S S S
S S S S S S S S S
S S S S S S S S
S S S
S
S SS
S S S
S S S S S S
S S S S S S S S
S S
S
SSSSSSS
S S S S S S
E
G G G
E
G
EG
EG
EG
EG
SSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S S S
S
S
S
S
S
S
S S
S S
S S S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S S
S
S
S
WW W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S S S S S S S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSS
SS
S
S
W W W
W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
W
W
W
W
WWWWWWWWW
W W W W
W W W
W W W W W W
W W W W
W W W
W
W W W WWW
W
W W
W
W
W
W W
W W W W W
S
W
W
W
W W
WWW
W
W
W
W W W W W W W W W W W W W W W W W
W
W
W WW W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W
W
WW
W
W
W
WW
W
W
W
W
W
W W W W W W W W W W
W
W
W
W W W
WWWWWWWW
W
W
W
S
W
W W
W W
W
W
S
W
S
WS
W
S
S
W
W
W
W
W
W
S
S
S
S
W
W
S
S
S
S
S
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
W
GESW EE E E EE EWWWWWWWSSSSSSGGGGGGG
E EE EE EE EEWWWWWWWW WSSSSSSSSSGGGGGGGG
G
G G
G G
S S
S
E
E E
EE
W W
W W
W
W
S S S
SG
S
S
W
W
W
W
F
F
F
F
W
FFW
WF
WF
SS
S
S
W
W W W W
W
W
S
W
W W
W
W
W
W
W
W
WDP
DP
WW
DP
DP
DP DP
DP
EE EE
SSS
SSSS
WWW
EEEGGG
EE
W W
W W
S S
S
S
S
EE GG
G G
G G G G
W W W W
S
G
S S SGGG S S SGGG
W SW S SWW S
E E E
W
DPE E E
W
DPE
DP
WW W
EEE DP
WW W
EEE DP
WW W
EEE
GS
S
G SSGSGSSGS
S WSWWSSWWSSWSWWS
G
G
EG EG EG E G EG EG EG EG E G
E G EG E G E G EG E G EG E G E G
EG E G EG EG EG E G EG E GEGEG
EG EG EG EG EG EG EG EGEGEG E G
G
EG E G EG EG EG EG E G EGEGEG
E
G
E
G
E
G
EG E EG G
EG EG EG EG EG EG EGEGEG EG EG EG
EG
W SW
SW
WS W W W W W W W WSSSSSSS S S W
WSSWWSSSSSSSSWWWWWWWW
W S
WSWSSW
W
S S S S SWWWW W
SW SW SW S S S
W W W
W S W S
W
EG EG EG
E
E
E
E
G
G
G
G
G E GE GE G E
E G
E G
W W S W
W
W
W
W
W
S
EGEGEG
EG
EGEG
EG EG EG GE GE
GE
G
WWWW
WW
W W
S
W
W
W
W
W
EG
G
E
G
E
EG
EG
EG
G E
G
E
GE
EG
S S S S SWWWW
G
S
W
E
S
E
E
G
G G
G
E G
G
G
E
E
E
E
G
E
VTC
SF
W
IP
IP
GB
MU
CWO
RS
GF
RR
NOTES: .
1.PERIMETER SILT FENCE SHALL BE INSTALLED ALONG PROPERTY
BOUNDARY, AND IS SHOWN OFFSET FROM PROPERTY BOUNDARY
ON THIS PLAN FOR CLARITY.
·TOTAL PERIMETER SILT FENCE AROUND SITE = 10,566 LF.
2.ALL DISTURBED AREAS ARE TO BE SEEDED AND MULCHED.
3.STOCK PILES SHALL NOT TO EXCEED 10' IN HEIGHT.
4.ALL OFFSITE AREAS DISTURBED DURING CONSTRUCTION ARE TO
BE RE-VEGETATED AND RETURNED TO HISTORIC CONDITION.
STRAW WATTLES OR GRAVEL INLET FILTERS MAY BE INSTALLED
(IF NECESSARY AND AS REQUIRED) ON EXISTING,
OFFSITE/DOWNSTREAM INLETS.
5.VEHICLE TRACKING PAD(S) LOCATIONS SHALL BE DETERMINED
BY THE CONTRACTOR, PRIOR TO CONSTRUCTION, AND SHALL BE
INSTALLED ACCORDINGLY.
6.SEE SHEET C-018 & C-019 FOR EROSION CONTROL NOTES AND
DETAILS. SYMBOLS SHOWN IN THIS PLAN ARE NOT TO SCALE.
7.PHASED EROSION CONTROL SEQUENCING AND PLANS WILL BE
SHOWN AND PROVIDED DURING FINAL DESIGN. SILT FENCE OR
STRAW WATTLES SHALL BE INSTALLED AROUND BLOCKS, AFTER
UTILITY AND STREET CONSTRUCTION AND GRADING IS
COMPLETE. THE EROSION MEASURES WILL BE INSTALLED WHERE
CONSTRUCTION WILL NOT BE DEVELOPED FOR AN EXTENDED
PERIOD OF TIME.
8.THE OFFSITE LIMITS OF DEVELOPMENT (EAST SIDE OF NEW DITCH
RELOCATION, SHALL HAVE DIRT BERM PLACED ALONG LIMITS OF
DEVELOPMENT LINE IN-LIEU-OF SILT FENCE.
9.INSTALL NORTH AMERICAN GREEN EROSION CONTROL FABRIC TO
4:1 SLOPES ADJACENT TO THE NO. 8 DITCH.
LEGEND .
INSTALL VEHICLE TRACKING PAD
INSTALL SILT FENCE
INSTALL CONCRETE WASHOUT
HAY OR STRAW DRY MULCH (1-5%)
INSTALL 12" STRAW WATTLE CHECK DAM
LIMITS OF DISTURBANCE
INSTALL CURB INLET GRAVEL FILTER
INSTALL AREA INLET GRAVEL FILTER
PROPOSED DIRECTION OF SURFACE FLOW
INSTALL ROCK SOCK FILTER
INSTALL GRAVEL CURB CHECK BAG
INSTALL NORTH AMERICAN GREEN C350
PROPOSED MAJOR CONTOUR - 5 FT INTERVAL
PROPOSED MINOR CONTOUR - 1 FT INTERVAL
EXISTING MAJOR CONTOUR - 5 FT INTERVAL
EXISTING MINOR CONTOUR - 1 FT INTERVAL
EXISTING DIRECTION OF SURFACE FLOW
INSTALL RIPRAP PROTECTION (TYPE M D =12")
65
64
15''SAN 15''SAN15''SAN 15''SAN
DP
DP
BLK
14
1
2
3
4
5
6
7
8
9
BLK
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLK
15
BLK
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
303132333435363738
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
BLK
15
BLK
15
BLK
16
BLK
17
BLK
19
BLK
18
BLK
21
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6 7 8
9
11
10
12
13
14
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19202122
1 2 3 4
5
6
7
8
9
101112131415
7
8
9
10
11
12
14
16
17
18
19
20
BLK
14
33 34
35
36
37
38
39
41 40
BLK
12
BLK
20
CL
A
R
I
O
N
L
A
N
E
BRIGHTWATER DRIVE
CLIPPER WAY
FIELD VIEW ROAD
GREENSPACE WAY
FO
R
U
M
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
WE
L
L
N
E
S
S
R
O
A
D
WEL
L
N
E
S
S
R
O
A
D
H
I
G
H
M
E
A
D
O
W
R
O
A
D
HI
G
H
M
E
A
D
O
W
R
O
A
D
STA
R
D
U
S
T
W
A
Y
TR
A
I
L
W
A
Y
R
O
A
D
PLAY
P
A
R
K
L
A
N
E
BA
R
H
A
R
B
O
R
D
R
I
V
E
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
RICHARDS LAKE ROAD
(TWO LANE ARTERIAL)
TRAILS CROSSING LANE
TRA
I
L
S
C
R
O
S
S
I
N
G
L
A
N
E
19
15
13
15''SAN 15''SAN15''SAN 15''SAN
DP
DP
W
.
P
.
E
L
D
E
R
R
E
S
E
R
V
O
I
R
O
U
T
L
E
T
C
A
N
A
L
TRACT B
LIND PROPERTY
REC. NO.
200030150497
BEA
C
H
C
O
M
B
E
R
L
A
N
E
T
H
O
R
E
A
U
R
O
A
D
24'x50'
POND 200
EX POND 100
25
3
0
24
26
27
28
29
3
1
3
2
33
2
5
30
35
40
4
5
5
0
2
6
2
7
28
2
9
3
1
32
33
34
36
37
38
39
41
42
43
44
4
6
4
7
4
8
4
9
5
1
5
2
52
5
2
5
3
53
53
5
3
5
3
5
2
52
4
5
50
4
4
46
47
48
49
51
52
45
50
43
44
46
47
48
49
51
52
53
3
0
3
0
3
5
3
5
4
0
4
5
5
0
29 29
3
1
3
1
3
2
3
2
3
3
3
3
3
4
3
4
36
3
6
37
3
7
38
3
8
39
3
9
4
1
4
2
4
3
4
4
4
6
4
7
4
8
4
9
5
1
40
45
36 3
637 37 38 39 41
42
43
44
46
35
40
33
34
36
37
38
39
41
25
2
5
2
5
24
2
6
2
7
2
8
2
9
53
45
50
44
46
4748
51
52
53
54
4344
50
46
47
48
49
5
1
5
2
45
50
44
46
47
48
49
51
5
2
5
3
5
4
50
46
47
48
49
51
52
53
40
45
50
37
38
39
41
42
43
44
46
47
48
49
51
52
53
30
35
262728
29
31
32
33
34
36
37
50
47
48
49
51
45
50
41
42
43
44
46
47
48
49
40
45
3
7
38
39
41
4
2
43
44
46
47
48
30
3
5
4
0
31
3
2
3
3
3
4
3
6
3
7
3
8
3
9
3
5
4
0
3
2
3
3
3
4
3
6
3
7
3
8
3
9
4
1
35
40
45
36
37
38
39
41
42
43
44
46
4
0
3
6
3
7
3
8
3
9
4
1
4
2
4
3
4
4
3
0
3
5
3
1
3
2
3
3
3
4
3
6
3
7
3
8
3
9
30
35
2
6
27
28
29
31
32
33
34
36
25
25
30
30
35
35
40
40
23
23
24
24
26
26
27
27
28
28
29
29
31
31
32
32
33
33
34
34
36
36
37
37
38
38
39
39
41
41
42
42
43
30
30
30
35
28
2929 29
3131
31
3232
32
333333
3434
34
5
2
5
1
39
38
37
42
37
4
0
3
9
4
0
4
1
4
2
4
1
4
2
4
2
3
8
3
7
5
3
28
28
25 24
21
25
43
4
2
4
2
4
1
4
0
4
1
5
3
53
5
4
5
4
4
7
45
44
43
46
5
0
5
3
5
0
4
5
4
3
3
231
3
1
5554
53
54
54
35
3
6
3
7
3
8
3
9
40
34
34
35
33
29
30
44
25
28
2923
23
25
28
28
2726
25
29
42
41
40
39
38
37
30
31
32
33
34
32
31
34
30
28
2
9
31
32
33
34
28
2
9
31
32
33
30
35
36
37
38
IP
RR RR
RR
RR
IP
IP
IP IP
IP
RR
IP
IP
IP
IP
IP
IP
IP
IP IP
IP
IP
IP IP
GB
W
W
W
W
GB
GB
GB
GB
GB GB
GB
GB
GB
GB
GB
GB
GB
GB
GBGB
GB
GB
IP
EX PROPERTY BOUNDARY
PROP DRAINAGE EASEMENT
EX PROPERTY BOUNDARY
PROP CONC WINGWALL/ RETAINING WALL
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF
DEVELOPMENT PROP MSE
WALLS
PROP LIMITS OF DEVELOPMENT
PROP TEMPORARY CONSTRUCTION EASEMENT
PROP TEMPORARY CONSTRUCTION EASEMENT
PROP CONC DROP STRUCTURE
PROP DRAINAGE EASEMENT
PROP DRAINAGE EASEMENT
EX PRESCRIPTIVE
EASEMENT
PROP DITCH EASEMENT
PROP TOP (TOP OF BANK) OF NO. 8 DITCH
PROP BOTTOM (TOE OF SLOPE) OF NO. 8 DITCH
PROP LIMITS OF DEVELOPMENT
PROP LIMITS OF
DEVELOPMENT
PROP DITCH EASEMENT
PROP TOP (TOP OF BANK) OF NO. 8 DITCH
PROP BOTTOM (TOE OF SLOPE) OF NO. 8 DITCH
PROP LIMITS OF DEVELOPMENT
EX PROPERTY BOUNDARY
PROP CONC C&G W/ 2' ASPHALT PATCH
EX PROPERTY
BOUNDARY
PROP LIMITS OF
DEVELOPMENT
PROP DRAINAGE EASEMENT
VTC
REFER TO NOTE 9 THIS SHEET
REFER TO NOTE 9 THIS SHEET
REFER TO NOTE 9 THIS SHEET
IPIP
ASPEN
0'
SCALE: 1" = 100'
100'200'
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
S
O
U
T
H
E
A
S
T
)
C-017
17 84
AUGUST 7, 2024
105001
JRG
JRG
JRG
KEY MAP - 1" = 1000'
017
016
015
KEY MAP - 1" = 1000'
Street Cut Note
MAT
C
H
L
I
N
E
SEE
S
H
E
E
T
C
-
0
1
6
TOTAL
ONSITE AREA
DISTURBED
(SF)
5,641,981
TOTAL
OFFSITE AREA
DISTURBED
(SF)
3,744,027
1.PROJECT WILL BE CONSTRUCTED IN MULTIPLE PHASES.
2.STORAGE/STAGING AREAS SHALL BE WITHIN THE AREA OF DISTURBANCE/ LIMITS OF
DEVELOPMENT.
3.NO HAUL ROADS OFFSITE ARE EXPECTED.
4.HEAVY CONSTRUCTION TRAFFIC TO BE ROUTED IN COORDINATION WITH THE SONDERS EAST
PROJECT MANAGER, PRIOR TO START OF CONSTRUCTION.
5.GROUNDWATER DEPTHS ARE BASED ON BORING INFORMATION COMPLETED FOR SONDERS EAST,
BY CTL THOMPSON, PROJECT NO. FC08010.003-115.
6.SITE SLOPES SHALL BE NO GREATER THAN 4:1.
7.NO RIPARIAN OR SENSITIVE AREAS ARE IDENTIFIED WITH THIS PROJECT.
DISTURBANCE
AT ANY
ONE TIME
(%)
100
EXISTING
VEGETATION
DENSITY
(%)
VARIES
60-85%
EXISTING
SOIL TYPE
TYPE A
SOIL
GROUND
WATER
LEVEL
(FT)
16' to 29'
MATERIAL
CUT/FILL
(CF)
38,329,443
PROJECT DETAILS
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
ER
O
S
I
O
N
C
O
N
T
R
O
L
N
O
T
E
S
&
D
E
T
A
I
L
S
C-018
18 84
AUGUST 7, 2024
105-001
JRG
JRG
JRG
www.herefordnrcd.com/Straw_Wattles.pdf) AND PER DETAILS
AND INSTALLATION INSTRUCTIONS CALLED FOR ON THIS SHEET.
2. IF GRAVEL INLET FILTERS ARE USED, REFER TO "CURB INLET GRAVEL FILTER" DETAIL, THIS SHEET.
STRAW
WATTLE/ROCK
SOCK CHECK
DAM
www.herefordnrcd.com/Straw_Wattles.pdf
WOODEN
STAKE
(TYP)STRAW
WATTLE WOODEN
STAKE
(TYP)
EMBED
WATTLE/ROCK
SOCK FILTERS
3" TO 5" INTO
SOIL
EMBED
WATTLE/ROCK
SOCK 3" TO 5"
INTO SOIL
General Erosion Control Requirements
These notes are a summary for the legal requirements, that are set forth in the Fort Collins Stormwater Criteria Manual (FCSCM), and that any conflict is resolved
by the more stringent requirement controlling.
1)The Property Owner, Owner's Representative, Developer, Design Engineer, General Contractor, Sub-contractors, or similar title for the developing entity
(here after referred to as the Developer) has provided these Erosion Control Materials in accordance with Erosion Control Criteria set forth in the Manual as an
attempt to identify erosion, sediment, and other potential pollutant sources associated with these Construction Activities and preventing those pollutants from
leaving the project site as an illicit discharge. Full City requirements and are outlined and clarified in the Manual under Chapter 4: Construction Control Measures
and should be used to identify and define what is needed on a project.
2)The Developer shall make themselves thoroughly familiar with the provisions and the content of the specifications laid out in the Manual, the Development
Agreement, the Erosion Control Materials compiled for this project, and the following notes as all these materials are applicable to this project.
3)The Developer shall implement and maintain Control Measures for all potential pollutants from the start of land disturbing activities until final stabilization
of the construction site.
4)The City Erosion Control Inspector shall be notified at least twenty-four (24) hours prior to the desired start of any construction activities on this site to
allow adequate time for on-site confirmation (initial inspection which can take up to two business days after receiving the request) that the site is in fact protected
from sediment and pollutants discharges off site. Please contact erosion@fcgov.com early to schedule those Initial Erosion Control Inspections well in advance so
that demolition, clearing, grubbing, tree removal, and scraping may begin without delay. Failure to receive an on-site confirmation before construction activities
commence is an automatic “Notice of Violation” and can result in further enforcement actions.
5)The Developer shall proactively provide all appropriate Control Measures to prevent damage to adjacent downstream and leeward properties. This includes
but is not limited to: trees, shrubs, lawns, walks, pavements, roadways, structures, creeks, wetlands, streams, rivers, and utilities that are not designed for removal,
relocation, or replacement in the course of construction.
6)At all times the Developer shall be responsible to ensure adequate Control Measures are designed, selected, installed, maintain, repaired, replaced, and
ultimately removed in order to prevent and control erosion suspension, sediment transportation, and pollutant discharge as a result of construction activities
associated with this project.
7)All applicable Control Measures based upon the sequencing and/or phasing of the project shall be installed prior to those construction activities
commencing.
8)As dynamic conditions (due to the nature, timing, sequence, and phasing of construction) in the field may warrant Control Measures in addition, or different,
to what is shown on these plans, the Developer shall at all times be responsible to implement the Control Measures that are most effective with the current state
and progress of construction. The Developer shall implement whatever measures are determined necessary, and/or as directed by the City Erosion Control
Inspector. The Developer shall insure that all Erosion Control Plans (Maps) or SWMP documents are updated to reflect the current site conditions, with updates
being initialed and dated. These site inspections and site condition updates shall be made available upon request by the City.
9)All listings, provisions, materials, procedures, activities, site work and the like articulated in this or other written site-specific documents (Including but not
limited to the erosion control reports, development agreements, landscape, and drainage materials) shall meet or exceed the most restrictive language for City,
County, State, and Federal regulations with regards to erosion, sediment, pollutant, and other pollution source Control Measures. The Developer shall be
responsible to comply with all of these aforementioned laws and regulations.
10)The Developer shall ensure that all appropriate permits (CDPS General Permit Stormwater Discharges Associated with Construction Activity, Dewatering,
Clean Water Act, Army Corps of Engineers' 404 Wetlands Mitigation Permit, etc.) have been attained prior to the relevant activity has begun. These permits or
copies shall be made available upon request by the City.
11)The Developer shall furnish all conveniences and assistances to aid the Erosion Control Inspectors of materials, workmanship, records, and self-inspections,
etc. of the Control Measures involved in the construction activities.
12)The Developer shall request clarification of all apparent site construction issues that may arise due to inconsistencies in construction plans for the site or site
conditions around the selected Control Measures by contacting the Erosion Control Inspector. The Erosion Control Inspector will not be responsible for any
explanations, interpretations, or supplementary data provided by others.
13)All Control Measures shall be installed in accordance with the Manual.
14)The City reserves the right to require additional Control Measures as site conditions warrant, to the extent authorized by relevant legal authority.
15)As with any construction standards, occasions may arise where the minimum erosion control standards are either inappropriate or cannot be justified. In
these cases, a variance to these standards may be applied for pursuant to the terms, conditions, and procedures of the Manual.
16)Inspection. The contractor shall inspect site pollutant sources and implement Control Measures at a minimum of once every two weeks during construction
and within 24 hours following a precipitation event. Documentation of each inspection shall be recorded and retained by the contractor.
17)All temporary Control Measures shall be cleaned, repaired, or reconstructed as necessary in order to assure continual performance of their intended
function. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their
release into any drainage way.
18)Any Control Measure may be substituted for another standard Control Measure so long as that Control Measure is equal to, or of greater protection than
the original Control Measure that was to be used in that location. (ex. silt fence, for wattles, or for compact berms) Wattle alone on commercial construction sites
have shown to be an ineffective substitute for silt fence or compact berms unless it is accompanied by a construction fence to prevent vehicle traffic.
19)Any implementation or replacement of existing Control Measures for a non-standard control, or alternative Control Measure, shall require the review and
acceptance by the City erosion control staff before the measure will be allowed to be used on this project. These Control Measures' details shall be submitted,
reviewed and accepted to be in accordance with the Erosion Control Criteria based upon the functionality and effectiveness in accordance with sound engineering
and hydrological practices
Land disturbance, Stockpiles, and Storage of Soils
20)There shall be no earth-disturbing activity outside the limits designated on the accepted plans. Off road staging areas or stockpiles must be preapproved by
the City. Disturbances beyond these limits will be restored to original condition.
21)Pre-disturbance vegetation shall be identified, protected, and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to
the area required for immediate construction operations, and for the shortest practical period of time. This should include sequencing and phasing construction
activities in a way so that the soil is not exposed for long periods of time by schedule or limit grading to small areas. This should also include when practical
advancing the schedule on stabilization activities such that landscaping takes place shortly if not immediately after grading has occurred. Vegetation efforts shall
start as soon as possible to return the site to a stabilized condition. Sensitive areas should avoid clearing and grading activities as much possible.
22)All exposed soils or disturbed areas are considered a potential pollutant and shall have Control Measures implemented on the site to prevent materials from
leaving the site.
23)All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition at all
times by equipment tracking, scarifying or disking the surface on a contour with a 2 to 4 inch minimum variation in soil surface until mulch, vegetation, and/or
other permanent erosion control is installed.
24)No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport through the use of surface roughening,
watering, and down gradient perimeter controls. All soil stockpiles shall be protected from sediment transport by wind in accordance with Municipal Code §12-150.
All stockpiles shall be flattened to meet grade or removed from site as soon as practical, and no later than the completion of construction activities or
abandonment of the project. All off-site stockpile storage locations in City limits shall have a stockpile permit from the City Engineering Department prior to using
the area to store material. If frequent access from hardscape to the stockpile is needed a structural tracking Control Measure shall be implemented.
25)All required Control Measures shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc.). All of the required erosion Control
Measures must be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion
control report.
26)All inlets, curb-cuts, culverts, and other storm sewer infrastructure which could be potentially impacted by construction activities shall be protected with
Control Measures. Material accumulated from this Control Measure shall be promptly removed and in cases where the protection has failed, the pipes shall be
thoroughly cleaned out.
27)All streams, stream corridors, buffers, woodlands, wetlands, or other sensitive areas shall be protected from impact by any construction activity through the
use of Control Measures.
28)All exposed dirt shall have perimeter control. Any perimeter controls that drain off or has the ability to be tracked onto the nearby hardscape shall have
some form of effective sediment control as the, or as part of the, perimeter control.
29)All exposed slopes should be protected. All exposed steep slopes (Steeper than 3:1 H:V) shall be protected from erosion and sediment transport through use
of Control Measures.
30)No soils shall remain exposed by land disturbing activity for more than thirty (30) days after activity has ceased before required temporary seeding or
permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. This is not just limited to projects that are abandoned; this includes any project that is
temporarily halted and no immediate activity is to resume within the next thirty (30) days, unless otherwise approved by the City Erosion Control Inspector. During
a season when seeding does not produce vegetative cover, another temporary erosion control shall be implemented with or until temporary seeding or permanent
erosion control can be performed.
31)All individual lots shall have effective sediment controls located on the street side and any down gradient side. Typically most lots drain to the front yet on
those cases where houses are along a pond or drainage swale have the lot drain in a different direction than the street, those individual lots will need protection on
that down gradient side to prevent sediment from leaving the lot. See the Individual Lot Details for further clarification.
Vehicle Tracking
32)At all points where vehicles exit or leave the exposed dirt area on to a hardscape or semi hardscape (concrete, asphalt, road base, etc.) shall have installed at
least one structural tracking Control Measure to prevent vehicle tracking. All areas not protected by an adequate perimeter control shall be considered a point
where vehicles exit the site. Access points should be limited to as few entrances as possible (All perimeter areas shall be protected from tracking activities).
33)In all areas that the structural tracking Control Measures fail to prevent vehicle tracking, collection and proper disposal of that material is required. All inlets
located near access points and affected by tracking activities shall be prevented from the introduction of sediment into the drainage system.
34)City Municipal Code §20-62, among other things, prohibits the tracking, dropping, or depositing of soils or any other material onto city streets by or from any
source. City Municipal Code, §26-498, among other things, prohibits the discharge of pollutants on public or private property if there is a significant potential for
migration of such pollutant. Therefore, all tracked or deposited materials (intentional or inadvertent) are not permitted to remain on the street or gutter and shall
be removed and legally disposed of by the Developer in a timely and immediate manner. Dirt ramps installed in the curb-lines are not exempt to these sections of
code and shall not be permitted in the street right of way (public or private).
35)If repeated deposit of material occurs on a site, additional structural tracking controls may be required of the Developer by the City Erosion Control
Inspector. Loading and Unloading Operations
36)The Developer shall apply Control Measure to limit traffic (site worker or public) impacts and proactively locate material delivered to the site in close
proximity to the work area or immediately incorporated in the construction to limit operational impacts to disturbed areas, vehicle tracking, and sediment
deposition that could impact water quality.
Outdoor Storage or Construction Site Materials, Building Materials, Fertilizers, and Chemicals
37)Any materials of a non-polluting nature (steel, rock, brick, lumber, etc.) shall be inspected for any residue coming off the material during routine inspection
and will generally be located where practical at least fifty (50) feet from any permanent or interim drainage ways.
38)Any high environmental impact pollutant materials that have a high likelihood to result in discharge when in contact with stormwater (lubricants, fuels,
paints, solvents, detergents, fertilizers, chemical sprays, bags of cement mix, etc.) should not be kept on site where practical. When not practical, they should be
stored inside (vehicle, trailer, connex, building, etc.) and out of contact with stormwater or stormwater runoff. Where not available, they shall be stored outside in
a raised (high spots or on pallets), covered (plastic or tarped), and sealed (leak proof container) in secondary containment location. The secondary containment or
other Control Measure shall be adequately sized, located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage
ways and shall be monitored as part of the routine inspections.
Vehicle and equipment maintenance and fueling
39)Parking, refueling, and maintenance of vehicles and equipment should be limited in one area of the site to minimize possible spills and fuel storage areas.
This area shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as
part of the routine inspections. All areas shall keep spill kits and supplies close.
Significant Dust or Particulate generating Process
40)The property must be actively preventing the emission of fugitive dust at all times during construction and vegetation activities. All land disturbing activities
that result in fugitive dust shall be in accordance with Municipal Code §12-150 to reduce the impacts to adjacent properties and community health. All required
practices shall be implemented and additional ones shall be followed. These practices include watering the sites and discontinuing construction activities until the
wind subsides as determined by any City Inspectors.
Concrete truck / equipment washing, including the concrete truck chute and associated fixtures and equipment
41)All concrete and equipment washing shall use structural Control Measures appropriate to the volume of wash and frequency of use. These Control Measures
shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as part of
the routine inspections. These areas shall be clearly identified and protected from any wash from leaving the Control Measure. If frequent FORT COLLINS
STORMWATER CRITERIA MANUAL Appendix F Page 7 access from hardscape to the Control Measure is to occur, a structural tracking Control Measure shall be
implemented. These Control Measures shall be frequently cleaned out.
42)The Developer is responsible for ensuring washing activity is taking place at the appropriate Control Measure and site workers are not washing or dumping
wash water on to the dirt or other uncontrolled locations.
Dedicated Asphalt and concrete batch plants
43)Dedicated asphalt and concrete batch plants are not acceptable on construction sites within the City of Fort Collins without an expressed written request
and plan to reduce pollutants associated with that type of activity and approval by the City of Fort Collins specifically the Erosion Control Inspector. The Developer
shall inform the erosion control inspection staff of any dedicated asphalt, or concrete batch plants that is to be used on site.
Concrete Saw Cutting Materials
44)Saw cutting material shall be in accordance with Municipal Code §12-150 for air emissions and all water applications to the saw cutting shall prevent
material from leaving the immediate site and collected. These cutting locations, once dried, shall be swept and scraped of all material and shall have proper and
legal disposal.
Waste Materials Storage and Sanitary Facilities
45)Trash, debris, material salvage, and/or recycling areas shall be, where practical, at least fifty (50) feet from any permanent or interim stormwater structures
or drainage ways and shall be monitored as part of the routine inspections. These facilities should be located out of the wind and covered as able. Where not able to
cover, locating said areas on the side of other structures to reduce exposure to winds, and follow maximum loading guidelines as marked on the container. The
Developer is required to practice good housekeeping to keep the construction site free of litter, construction debris, and leaking containers.
46)Sanitary facilities shall be prevented from tipping through the use of anchoring to the ground or lashing to a stabilized structure. These facilities shall also be
located as far as practical from an inlet, curb cut, drainage swale or other drainage conveyances to prevent material transport from leaving the local area. This
consists of the facility being located, where practical, at least fifty (50) feet from any permanent or interim drainage ways.
Other Site Operations and Potential Spill Areas
47 )Spills: For those minor spills that; are less than the State's reportable quantity for spills, stay within the permitted area, and in no way threaten any
stormwater conveyance, notify the FORT COLLINS STORMWATER CRITERIA MANUAL Appendix F Page 8 City of Fort Collins Utilities by email at erosion@fcgov.com
or phone (970) 817-4770. For any significant, major, or hazardous spills, notify the City of Fort Collins Utilities by phone only after Emergency Response (911) has
been notified and is on route, County Health Department (LCDHE) has been notified through Larimer County Sheriff Dispatch (970) 416-1985, and the State Spill
Hotline Incident Reporting have been contacted 1-877-518-5608. Written documentation shall be provided to the City within 5 days of the event. All spills shall be
cleaned up immediately.
48)Selection of “plastic welded” erosion control blankets shall not be used in areas that wildlife, such as snakes, are likely to be located as these have proven to
cause entrapment issues.
Final stabilization and project completion
49) Any stormwater facilities used as a temporary Control Measure will be restored and storm sewer lines will be cleaned upon completion of the project and
before turning the maintenance over to the Owner, Homeowners Association (HOA), or other party responsible for long term maintenance of those facility.
50)All final stabilization specifications shall be done in accordance with the Manual, Chapter 4: Construction Control Measures.
51)All disturbed areas designed to be vegetated shall be amended, seeded & mulched, or landscaped as specified in the landscape plans within 14 working days
of final grading.
52 Soil in all vegetated (landscaped or seeded) areas, including parkways and medians shall comply with all requirements set forth in Sections 12-130 through
12-132 of the City Municipal Code, as well as Section 3.8.21 for the City Land Use Code.
53)All seeding shall refer to landscaping plans for species mixture and application rates and depths requirements.
54)All seed shall be drilled where practical to a depth based upon the seed type. Broadcast seeding shall be applied at double the rate as prescribed for drill
seeding and shall be lightly hand raked after application. Hydroseeding may be substituted for drill seeding on slopes steeper than 3(H):1(V) or on other areas not
practical to drill seed and crimp and mulch. All hydroseeding must be conducted as two separate processes of seeding and tackification.
55)All seeded areas must be mulched within twenty-four (24) after planting. All mulch shall be mechanically crimped and or adequately applied tackifier. The use
of crimped mulch or tackifier may require multiple re-applications if not properly installed or have weathered or degraded before vegetation has been established.
Areas of embankments having slopes greater than or equal to 3H:1V shall be stabilized with an erosion mat or approved equal to ensure seed will be able to
germinate on the steep slopes. During a season when seeding does FORT COLLINS STORMWATER CRITERIA MANUAL Appendix F Page 9 not produce vegetative
cover, another temporary erosion control shall be implemented along with, or until, temporary seeding or permanent erosion control can be performed.
56)The Developer shall warranty and maintain all vegetative measures for two growing seasons after installation or until seventy percent (70%) vegetative cover
has been established, whichever is longer and meets all the Criteria outlined in the Fort Collins Stormwater Criteria Manual Chapter 4: Construction Control
Measures.
57)The Developer shall maintain, monitor, repair, and replace any and all applicable Control Measures until final stabilization has been obtained. All Control
Measures must remain until such time as all upstream contributing pollutant sources have been vegetated or removed from the site. When any Control Measure is
removed, the Developer shall be responsible for the cleanup and removal of all sediment and debris from that Control Measure. At the point at which the site has
been deemed stabilized and verified by City Erosion Control Inspector, all temporary Control Measures can then be fully removed. All measures shall be removed
within 30 days after final stabilization is achieved.
58) The responsible party shall maintain and keep current all payments or related forms of security for the Erosion Control Escrow until 1) stabilization has been
reached and 2) all Control Measures and/or BMPs have sediment materials collected and the Control Measure removed from the site. At that time the site will be
considered completed and any remaining Erosion Control Escrow shall be returned to the appropriate parties.
SHEET No:
PR
O
J
E
C
T
/
L
O
C
A
T
I
O
N
:
DR
A
W
I
N
G
:
OF
CHECKED BY:
DESIGNED BY:
DRAWN BY:
DE
S
C
R
I
P
T
I
O
N
O
F
R
E
V
I
S
I
O
N
:
DA
T
E
:
RE
V
I
S
E
D
B
Y
:
AP
P
R
O
V
E
D
B
Y
:
RE
V
.
#
1 2 3 4 5 6 7
PRE
L
I
M
I
N
A
R
Y
NOT
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
project no:
date:
SO
N
D
E
R
S
E
A
S
T
FO
R
T
C
O
L
L
I
N
S
,
C
O
L
O
R
A
D
O
ER
O
S
I
O
N
C
O
N
T
R
O
L
D
E
T
A
I
L
S
C-019
19 84
AUGUST 7, 2024
105-001
JRG
JRG
JRG
SLOPE
INSTALLATION
DETAIL
Drawing Not To Scale
1.Prepare soil before installing rolled
erosion control products (RECPs),
including any necessary
application of lime, fertilizer, and
seed.
2.Begin at the top of the slope by
anchoring the RECPs in a
6"(15cm) deep X 6"(15cm) wide
trench with approximately 12"
(30cm) of RECPs extended beyond
the up-slope portion of the trench.
Anchor the RECPs with a row of
staples/stakes approximately 12"
(30cm) apart in the bottom of the
trench. Backfill and compact the
trench after stapling. Apply seed to
the compacted soil and fold the
remaining 12"(30cm) portion of
RECPs back over the seed and
compacted soil. Secure RECPs
over compacted soil with a row
of staples/stakes spaced
approximately 12"(30cm) apart
across the width of the RECPs.
3.Roll the RECPs (A) down or (B)
horizontally across the slope.
RECPs will unroll with appropriate
side against the soil surface. All
RECPs must be securely fastened
to soil surface by placing
staples/stakes in appropriate
locations as shown in the staple
pattern guide.
4.The edges of parallel RECPs must
be stapled with approximately 2" -
5" (5-12.5cm) overlap depending
on the RECPs type.
5.Consecutive RECPs spliced down
the slope must be end over end
(Shingle style) with an approximate
3"(7.5cm) overlap. Staple through
overlapped area, approximately
12"(30cm) apart across entire
RECPs width.
Drawn on: 5-4-17
Disclaimer:
The information presented herein is general design information only. For specific applications,
consult an independent professional for further design guidance.
2"-5"
(5-12.5cm)
3B
4
2
5
1
3A
12"(30cm)
6"
(15cm)
6"
(15cm)
*NOTE:
In loose soil conditions, the use of
staple or stake lengths greater than
6"(15cm) may be necessary to
properly secure the RECP's.
3"(7.5cm)
5401 St. Wendel - Cynthiana Rd.
Poseyville, IN 47633
PH: 800-772-2040
www.nagreen.com
CHANNEL
INSTALLATION
DETAIL
Drawing Not To Scale
1.Prepare soil before installing rolled
erosion control products (RECPs),
including any necessary application of
lime, fertilizer, and seed.
2.Begin at the top of the channel by
anchoring the RECPs in a 6"(15cm)
deep X 6"(15cm) wide trench with
approximately 12"(30cm) of RECPs
extended beyond the up-slope portion
of the trench. Use ShoreMax mat at the
channel/culvert outlet as supplemental
scour protection as needed. Anchor the
RECPs with a row of staples/stakes
approximately 12"(30cm) apart in the
bottom of the trench. Backfill and
compact the trench after stapling. Apply
seed to the compacted soil and fold the
remaining 12"(30cm) portion of RECPs
back over the seed and compacted soil.
Secure RECPs over compacted soil
with a row of staples/stakes spaced
approximately 12" apart across the
width of the RECPs.
3.Roll center RECPs in direction of water
flow in bottom of channel. RECPs will
unroll with appropriate side against the
soil surface. All RECPs must be
securely fastened to soil surface by
placing staples/stakes in appropriate
locations as shown in the staple pattern
guide.
4.Place consecutive RECPs end-over-end
(Shingle style) with a 4"-6" overlap. Use
a double row of staples staggered 4"
apart and 4" on center to secure
RECPs.
5.Full length edge of RECPs at top of side
slopes must be anchored with a row of
staples/stakes approximately 12"(30cm)
apart in a 6"(15cm) deep X 6"(15cm)
wide trench. Backfill and compact the
trench after stapling.
6.Adjacent RECPs must be overlapped
approximately 2"-5" (5-12.5cm)
(Depending on RECPs type) and
stapled.
7.In high flow channel applications a
staple check slot is recommended at 30
to 40 foot (9 -12m) intervals. Use a
double row of staples staggered
4"(10cm) apart and 4"(10cm) on center
over entire width of the channel.
8.The terminal end of the RECPs must be
anchored with a row of staples/stakes
approximately 12" (30cm) apart in a
6"(15cm) deep X 6"(15cm) wide trench.
Backfill and compact the trench after
stapling.
Drawn on: 5-4-17
Disclaimer:
The information presented herein is general design information only. For specific applications,
consult an independent professional for further design guidance.
2"-5"
(5-12.5cm)
6
2
4
12"(30cm)
6"
(15cm)
6"
(15cm)
4"-6"
(10-15cm)
8
6"
(15cm)
5 7
4"(10cm)
3
1
A
B
C
A
B C
NOTES:
*Horizontal staple spacing should be
altered if necessary to allow staples to
secure the critical points along the channel
surface.
**In loose soil conditions, the use of staple
or stake lengths greater than 6"(15cm) may
be necessary to properly secure the
RECP's.
CRITICAL POINTS
A. Overlaps and Seams
B. Projected Water Line
C. Channel Bottom/Side Slope Vertices
4"(10cm)
6"
(15cm)
5401 St. Wendel - Cynthiana Rd.
Poseyville, IN 47633
PH: 800-722-2040
www.nagreen.com
OUTLET PIPE
ENDS OF GRAVEL FILTER TO BE
KEYED INTO FILL SLOPE.
TOE OF FILL
FLOW
GRAVEL FILTER
(3/4"Ø ± GRAVEL,
WRAPPED IN CHICKEN
WIRE)
MAINTENANCE NOTES:
1. FORM CHICKEN WIRE WRAP ALONG FRONT OF OUTLET STRUCTURE AND EXTENDING INTO EMBANKMENT OF POND.
2. PACK WITH 3/4" GRAVEL AND ROLL & TWIST CHICKEN WIRE WRAP AT TOP TO HOLD TOGETHER (WIRE TIE, IF NECESSARY).
GRAVEL FILTER SHALL BE 18" TALL x 18" WIDE AND SLOPE TOWARDS OUTLET STRUCTURE OR LAID UP AGAINST OUTLET
STRUCTURE FOR STABILITY.
3. SEDIMENT BASIN FILTER SHALL BE INSPECTED PERIODICALLY AND AFTER EACH RAIN EVENT, AND REPAIRED WHEN
NECESSARY. ACCUMULATED SEDIMENT SHALL BE REMOVED.
4. SEDIMENT BASIN FILTER SHALL BE REMOVED AFTER IT HAS SERVED ITS PURPOSE.
OUTLET PIPEFILTERED
WATERRUNOFF
18" TALL GRAVEL FILTER.
18"
18"
OUTLET STRUCTURE
OUTLET STRUCTURE