HomeMy WebLinkAboutTHE MARK - FDP240013 - SUBMITTAL DOCUMENTS - ROUND 1 - Site, Landscape & Elevations PlansLAND USE CHART
EXISTING ZONING CG - GENERAL COMMERCIAL W/ TOD OVERLAY
PROPOSED ZONING CG - GENERAL COMMERCIAL W/ TOD OVERLAY
TOTAL GROSS AREA 122,093 SF / 2.80 AC
EXISTING LAND USE RESIDENTIAL W/ SUPPORTING OFFICE/COMMERCIAL
PROPOSED LAND USE RESIDENTIAL
FLOOR AREA RATIO N/A
SITE AREA (AC)SITE AREA (SF)%TOTAL
PROPERTY LIMIT IMPROVEMENTS
BUILDING/PARKING GARAGE 1.69 73,537 60%
DRIVEWAY .006 250 .21%
PLAZAS AND WALKS .14 6,307 5%
LANDSCAPE AREA (turf, plant beds).18 7,750 6.43%
NATURAL HABITAT BUFFER .51 22,210 18.2%
R.O.W. :
ROADWAY .14 6,191
SIDEWALKS .08 3,405
TREE LAWNS .05 1,965
PROPOSED BUILDING INFORMATION
MAXIMUM PROPOSED BUILDING HEIGHT = 74'
TOTAL SQUARE FOOTAGE (1ST- 6TH FLOOR) = 359,388 SF
RESIDENTIAL UNIT BREAKDOWN:
STUDIO UNIT: 80
1 BEDROOM UNIT: 4
2 BEDROOM UNIT: 32
3 BEDROOM UNIT: 59
4 BEDROOM UNIT: 18
TOTAL UNITS: 193
INTERIOR AMENITY SPACE SQUARE FOOTAGE: 12,226 SF
THIRD STORY COURTYARD SQUARE FOOTAGE: 22,016 SF
REQUIRED CAR PARKING:
0.75 / BEDROOM (397 BEDROOMS): 298
TOTAL PARKING SPACES REQUIRED: 298
ALLOWABLE AMOUNT OF COMPACT SPACES: 40%
HANDICAP SPACES REQUIRED: 7
PROVIDED CAR PARKING
TYPE OF PARKING COMPONENT PROVIDED PARKING
STANDARD PARKING SPACES 201 SPACES
STANDARD PARKING SPACES FOR COMMERCIAL/RETAIL 7 SPACES
COMPACT PARKING SPACES 102 SPACES (32%)
HANDICAP PARKING SPACES PROVIDED:8 SPACES
TOTAL PARKING SPACES PROVIDED:318 SPACES
REQUIRED BIKE PARKING
1 PER BEDROOM = 397, MINIMUM OF 238 (60% ENCLOSED) 159 (40% FIXED)
PROVIDED BIKE PARKING
72 SPACES FIXED UNCOVERED
87 SPACES FIXED COVERED (SECOND FLOOR GARAGE)
88 SPACES COVERED (FIRST FLOOR GARAGE)
153 SPACES COVERED (SECOND FLOOR GARAGE)
TOTAL SPACES: 400 (159 FIXED, 241 COVERED)
SI
T
E
C
O
V
E
R
LS001
N O R T H
CONTEXT MAP
THE MARK AT FORT COLLINS
N O R T H
ZONING MAP: CG DISTRICT
SITE PLAN
SITE
SITE
T
T
ELEC
TC
W
S
O
X
X
X
X X
X
X
X
X
X
VAULT
ELEC
VAULT
F.O.
VAULT
F.O.
VAULT
F.O.
VAULT
ELEC
ELEC
TEST
STA
PH
PH
PH
PH
PH
PH
PH
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
E
E
E
E
E
E
E
E
E
E
E
EEE
E
EEEE
E E E E E
E E
E
E E E E E E E E
EE
W
W
W
W
W
W
W
W
W W W W W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM COMM COMM
G G
GG
G
G
G
G
G
G
C
O
M
M
CO
M
M
CO
M
M
CO
M
M
G G
G
G
G
G
G
G
G
GG
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXX
X
X
XX
X
X
X
XX
X
X
X
X X
X
X
X
X
X
ELEC
ELEC
ELEC
ELEC
ELEC
S
S
S
S
S
WV
W
WV
WV
W
WV
H Y D
W
W
W
D
ST
ST
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.
V.P.V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.V.P.
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
///////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////////////////////////////////////////////////////////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////
//////
/
///////
/
//
//
/
/
/
/
/
///////////////////
/
/
/
/
/
/
/
/
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
HYD
ST
ST
ST
ST
ST
ST
ST
ST
C C C C C C C C C C
C
CCCCCCCCCCCCC
C
C C C C C C C C C C C C C C C
C
C
C
C
C
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G G G G
E
E
E E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
F
I
VANVAN
area reserved for gas meters
area reserved
for electric meters
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
area reserved
for electric meters
OV
E
R
A
L
L
S
I
T
E
P
L
A
N
LS101010'20'20'40'N O R T H
C
C
C
C
C
C C C C C C C C C C C C C C C
C
C
C
C
C
C
C
C C C C C C C C C C C C C C C
C C C C C C C C C C C
C
C
C
C
SE
C
O
N
D
F
L
O
O
R
S
I
T
E
P
L
A
N
LS102
0 10'20'20'40'N O R T H
TY
P
I
C
A
L
C
O
U
R
T
Y
A
R
D
P
L
A
N
LS103
0 10'20'20'40'N O R T H
SI
T
E
D
E
T
A
I
L
S
LS501
SI
T
E
D
E
T
A
I
L
S
LS502
T
T
ELEC
TC
W
S
O
D
X
X
X
X X
X
X
X
X
X
VAULT
ELEC
VAULT
F.O.
VAULT
F.O.
VAULT
F.O.
VAULT
ELEC
ELEC
TEST
STA
D
PH
PH
PH
PH
PH
PH
PH
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
E
E
E
E
E
E
E
E
E
E
E
EEE
E
EEEE
E E E E E
E E
E
E E E E E E E E
EE
W
W
W
W
W
W
W
W
W W W W W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM COMM COMM
G G
GG
G
G
G
G
G
G
C
O
M
M
CO
M
M
CO
M
M
CO
M
M
G G
G
G
G
G
G
G
G
GG
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXX
X
X
XX
X
X
X
XX
X
X
X
X X
X
X
X
X
X
ELEC
ELEC
ELEC
ELEC
ELEC
S
S
S
S
S
WV
W
WV
WV
W
WV
HY D
W
W
W
D
ST
ST
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.
V.P.V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.V.P.
V.P.V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////////////////////////////////////////////////////////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////
//////
/
///////
//
/
/
/
/
/
/
/
/
///////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
/
/
/
/
HYD
ST
ST
ST
ST
ST
ST
ST
ST
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G G G G
E
E
E E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
F
I
VANVAN
area reserved for gas meters
area reserved
for electric meters
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
area reserved
for electric meters
OV
E
R
A
L
L
S
I
T
E
L
I
G
H
T
I
N
G
P
L
A
N
LL101010'20'20'40'N O R T H
CONTROL
IRR
AC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
B MST
X X
X X X X X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X X X X
M
XX
X
X
X X
X
X
XX
X
X
XX
X
X
X X
X
X
X X
X
X
X
X X
T1
T2
T3
T4
T5
T9
T10
T11
T12
T13
T14
T15
T16T17
T18T20
T21
T22
T7
T6
T8
T23
T24
T25
T27
T28
T29
T30
T26
T19
TR
E
E
I
N
V
E
N
T
O
R
Y
A
N
D
M
I
T
I
G
A
T
I
O
N
P
L
A
N
LP001
0 10'20'20'40'N O R T H
FTN CONTROL
IRR
CONTROL
IRR
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
VAULT
F.O.
VAULT
F.O.
VAULT
F.O.
T12A
T13A
T1A
T4A
T3A
T2A
T5A
T6A
T7A
T8A
T9A
T14A
T10A
T11A
CR
E
E
K
S
I
D
E
P
A
R
K
TR
E
E
I
N
V
E
N
T
O
R
Y
A
N
D
M
I
T
I
G
A
T
I
O
N
P
L
A
N
LP002
0 10'20'20'40'N O R T H
T
T
ELEC
W S
O
X
X
X
X X
X
X
X
X
X
TEST
STA
PH
PH
PH
PH
PH
PH
PH
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
E
E
E
E
E
E
E
E
E
E
E
EEE
E
EEEE
E E E E E
E E
E
E E E E E E E E
EE
W
W
W
W
W
W
W
W W W W W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
G G
GG
G
G
G
G
G
G
C
O
M
M
CO
M
M
CO
M
M
CO
M
M
G G
G
G
G
G
G
G
G
GG
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXX
X
X
XX
X
X
X
XX
X
X
X
X X
X
X
X
X
X
ELEC
ELEC
ELEC
ELEC
ELEC
S
S
S
S
S
WV
W
WV
WV
W
H Y D
W
W
D
ST
ST
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.
V.P.V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.V.P.
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////////////////////////////////////////////////////////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////
//////
/
///////
/
/
/
/
/
/
/
/
/
/
//////////////////
HYD
ST
ST
ST
ST
ST
ST
ST
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G G G G
E
E
E E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
F
I
VANVAN
area reserved for gas meters
area reserved
for electric meters
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
area reserved
for electric meters
HYDROZONE AREA (SF)WATER NEED
(GAL/SF)
ANNUAL WATER
USE (GAL)
0 18.0 0
5138 10.0 51382
29234 3.0 87702
34372 4.0 139084
–
’
OV
E
R
A
L
L
L
A
N
D
S
C
A
P
E
P
L
A
N
LP101
0 10'20'20'40'N O R T H
T
T
ELEC
TC
W S
O
X
X
X
X X
X
X
X
X
X
TEST
STA
PH
PH
PH
PH
PH
PH
PH
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
E
E
E
E
E
E
E
E
E
E
E
EEE
E
EEEE
E E E E E
E E
E
E E E E E E E E
EE
W
W
W
W
W
W
W
W
W W W W W W W W W W W W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM COMM COMM
G G
GG
G
G
G
G
G
G
C
O
M
M
CO
M
M
CO
M
M
CO
M
M
G G
G
G
G
G
G
G
G
GG
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXX
X
X
XX
X
X
X
XX
X
X
X
X X
X
X
X
X
X
ELEC
ELEC
ELEC
ELEC
ELEC
S
S
S
S
S
WV
W
WV
WV
W
WV
HYD
W
W
W
D
ST
ST
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.V.P.
V.P.V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.V.P.
V.P.
V.P.
V.P.V.P.V.P.V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.
V.P.V.P.
V.P.
/////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////////////////////////////////////////////////////////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
//
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////
//////
/
///////
/
//
/
/
/
/
/
/
/
////////////////////////////////////////////////////////////////////////
HYD
ST
ST
ST
ST
ST
ST
ST
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G G G G
E
E
E E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
F
I
VANVAN
area reserved for gas meters
area reserved
for electric meters
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
fo
r
e
l
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
ar
e
a
r
e
s
e
r
v
e
d
f
o
r
el
e
c
t
r
i
c
m
e
t
e
r
s
area reserved
for electric meters
REQUIRED 50' BUFFER ZONE CALCULATIONS
50' BUFFER AREA
REQUIRED 19,933 SF
REQUIRED BUFFER
DISTANCE 50 FEET
PROPOSED BUFFER ZONE CALCULATIONS
PROPOSED BUFFER AREA 18,194 SF
PROPOSED ADDITIONAL
AREA ENHANCED
(DETENTION POND)
3,348 SF
TOTAL PROPOSED
BUFFER AREA 21,542 SF
PROPOSED BUFFER ZONE CALCULATIONS
CONTINUED
MINIMUM BUFFER
DISTANCE 21 FEET
MAXIMUM BUFFER
DISTANCE 78 FEET
AVERAGE BUFFER
DISTANCE 42 FEET
BU
F
F
E
R
Z
O
N
E
D
I
A
G
R
A
M
LP102010'20'20'40'N O R T H
PL
A
N
T
I
N
G
D
E
T
A
I
L
S
LP501
IR
R
I
G
A
T
I
O
N
P
L
A
N
IR-1
IR
R
I
G
A
T
I
O
N
D
E
T
A
I
L
S
IR-2