Loading...
HomeMy WebLinkAboutTHE MARK - FDP240013 - SUBMITTAL DOCUMENTS - ROUND 1 - Site, Landscape & Elevations PlansLAND USE CHART EXISTING ZONING CG - GENERAL COMMERCIAL W/ TOD OVERLAY PROPOSED ZONING CG - GENERAL COMMERCIAL W/ TOD OVERLAY TOTAL GROSS AREA 122,093 SF / 2.80 AC EXISTING LAND USE RESIDENTIAL W/ SUPPORTING OFFICE/COMMERCIAL PROPOSED LAND USE RESIDENTIAL FLOOR AREA RATIO N/A SITE AREA (AC)SITE AREA (SF)%TOTAL PROPERTY LIMIT IMPROVEMENTS BUILDING/PARKING GARAGE 1.69 73,537 60% DRIVEWAY .006 250 .21% PLAZAS AND WALKS .14 6,307 5% LANDSCAPE AREA (turf, plant beds).18 7,750 6.43% NATURAL HABITAT BUFFER .51 22,210 18.2% R.O.W. : ROADWAY .14 6,191 SIDEWALKS .08 3,405 TREE LAWNS .05 1,965 PROPOSED BUILDING INFORMATION MAXIMUM PROPOSED BUILDING HEIGHT = 74' TOTAL SQUARE FOOTAGE (1ST- 6TH FLOOR) = 359,388 SF RESIDENTIAL UNIT BREAKDOWN: STUDIO UNIT: 80 1 BEDROOM UNIT: 4 2 BEDROOM UNIT: 32 3 BEDROOM UNIT: 59 4 BEDROOM UNIT: 18 TOTAL UNITS: 193 INTERIOR AMENITY SPACE SQUARE FOOTAGE: 12,226 SF THIRD STORY COURTYARD SQUARE FOOTAGE: 22,016 SF REQUIRED CAR PARKING: 0.75 / BEDROOM (397 BEDROOMS): 298 TOTAL PARKING SPACES REQUIRED: 298 ALLOWABLE AMOUNT OF COMPACT SPACES: 40% HANDICAP SPACES REQUIRED: 7 PROVIDED CAR PARKING TYPE OF PARKING COMPONENT PROVIDED PARKING STANDARD PARKING SPACES 201 SPACES STANDARD PARKING SPACES FOR COMMERCIAL/RETAIL 7 SPACES COMPACT PARKING SPACES 102 SPACES (32%) HANDICAP PARKING SPACES PROVIDED:8 SPACES TOTAL PARKING SPACES PROVIDED:318 SPACES REQUIRED BIKE PARKING 1 PER BEDROOM = 397, MINIMUM OF 238 (60% ENCLOSED) 159 (40% FIXED) PROVIDED BIKE PARKING 72 SPACES FIXED UNCOVERED 87 SPACES FIXED COVERED (SECOND FLOOR GARAGE) 88 SPACES COVERED (FIRST FLOOR GARAGE) 153 SPACES COVERED (SECOND FLOOR GARAGE) TOTAL SPACES: 400 (159 FIXED, 241 COVERED) SI T E C O V E R LS001 N O R T H CONTEXT MAP THE MARK AT FORT COLLINS N O R T H ZONING MAP: CG DISTRICT SITE PLAN SITE SITE T T ELEC TC W S O X X X X X X X X X X VAULT ELEC VAULT F.O. VAULT F.O. VAULT F.O. VAULT ELEC ELEC TEST STA PH PH PH PH PH PH PH SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E EEE E EEEE E E E E E E E E E E E E E E E E EE W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM G G GG G G G G G G C O M M CO M M CO M M CO M M G G G G G G G G G GG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX X X XX X X X XX X X X X X X X X X X ELEC ELEC ELEC ELEC ELEC S S S S S WV W WV WV W WV H Y D W W W D ST ST V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P. V.P.V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P.V.P. V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. /////// / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///// ////// / /////// / // // / / / / / /////////////////// / / / / / / / / //////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// HYD ST ST ST ST ST ST ST ST C C C C C C C C C C C CCCCCCCCCCCCC C C C C C C C C C C C C C C C C C C C C C LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD E E E E E E E E E E E E E E E G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E W F I VANVAN area reserved for gas meters area reserved for electric meters ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s area reserved for electric meters OV E R A L L S I T E P L A N LS101010'20'20'40'N O R T H C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C SE C O N D F L O O R S I T E P L A N LS102 0 10'20'20'40'N O R T H TY P I C A L C O U R T Y A R D P L A N LS103 0 10'20'20'40'N O R T H SI T E D E T A I L S LS501 SI T E D E T A I L S LS502 T T ELEC TC W S O D X X X X X X X X X X VAULT ELEC VAULT F.O. VAULT F.O. VAULT F.O. VAULT ELEC ELEC TEST STA D PH PH PH PH PH PH PH SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E EEE E EEEE E E E E E E E E E E E E E E E E EE W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM G G GG G G G G G G C O M M CO M M CO M M CO M M G G G G G G G G G GG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX X X XX X X X XX X X X X X X X X X X ELEC ELEC ELEC ELEC ELEC S S S S S WV W WV WV W WV HY D W W W D ST ST V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P. V.P.V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P.V.P. V.P.V.P. V.P.V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. //////////////////// / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///// ////// / /////// // / / / / / / / / /////////////////// / / / / / / / / / / / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / HYD ST ST ST ST ST ST ST ST LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD E E E E E E E E E E E E E E E G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E W F I VANVAN area reserved for gas meters area reserved for electric meters ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s area reserved for electric meters OV E R A L L S I T E L I G H T I N G P L A N LL101010'20'20'40'N O R T H CONTROL IRR AC CONTROL IRR CONTROL IRR CONTROL IRR B MST X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X X X X X X XX X X X X X X M XX X X X X X X XX X X XX X X X X X X X X X X X X X T1 T2 T3 T4 T5 T9 T10 T11 T12 T13 T14 T15 T16T17 T18T20 T21 T22 T7 T6 T8 T23 T24 T25 T27 T28 T29 T30 T26 T19 TR E E I N V E N T O R Y A N D M I T I G A T I O N P L A N LP001 0 10'20'20'40'N O R T H FTN CONTROL IRR CONTROL IRR ST ST ST ST ST ST ST ST ST ST ST ST ST VAULT F.O. VAULT F.O. VAULT F.O. T12A T13A T1A T4A T3A T2A T5A T6A T7A T8A T9A T14A T10A T11A CR E E K S I D E P A R K TR E E I N V E N T O R Y A N D M I T I G A T I O N P L A N LP002 0 10'20'20'40'N O R T H T T ELEC W S O X X X X X X X X X X TEST STA PH PH PH PH PH PH PH SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E EEE E EEEE E E E E E E E E E E E E E E E E EE W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M G G GG G G G G G G C O M M CO M M CO M M CO M M G G G G G G G G G GG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX X X XX X X X XX X X X X X X X X X X ELEC ELEC ELEC ELEC ELEC S S S S S WV W WV WV W H Y D W W D ST ST V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P. V.P.V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P.V.P. V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. //// / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///// ////// / /////// / / / / / / / / / / ////////////////// HYD ST ST ST ST ST ST ST LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD E E E E E E E E E E E E E E E G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E W F I VANVAN area reserved for gas meters area reserved for electric meters ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s area reserved for electric meters HYDROZONE AREA (SF)WATER NEED (GAL/SF) ANNUAL WATER USE (GAL) 0 18.0 0 5138 10.0 51382 29234 3.0 87702 34372 4.0 139084 – ’ OV E R A L L L A N D S C A P E P L A N LP101 0 10'20'20'40'N O R T H T T ELEC TC W S O X X X X X X X X X X TEST STA PH PH PH PH PH PH PH SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E EEE E EEEE E E E E E E E E E E E E E E E E EE W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M CO M M COMM COMM COMM G G GG G G G G G G C O M M CO M M CO M M CO M M G G G G G G G G G GG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXX X X XX X X X XX X X X X X X X X X X ELEC ELEC ELEC ELEC ELEC S S S S S WV W WV WV W WV HYD W W W D ST ST V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P.V.P. V.P.V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P.V.P. V.P. V.P. V.P.V.P.V.P.V.P. V.P. V.P. V.P. V.P.V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P. V.P.V.P. V.P. ///// / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///////////////////////////////////////////////////////////////////////////////////////////////////////////// / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / ///// ////// / /////// / // / / / / / / / //////////////////////////////////////////////////////////////////////// HYD ST ST ST ST ST ST ST LO D LO D LO D LO D LO D LO D LO D LO D LO D LOD LOD LOD LOD LOD LOD LOD E E E E E E E E E E E E E E E G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E W F I VANVAN area reserved for gas meters area reserved for electric meters ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d fo r e l e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s ar e a r e s e r v e d f o r el e c t r i c m e t e r s area reserved for electric meters REQUIRED 50' BUFFER ZONE CALCULATIONS 50' BUFFER AREA REQUIRED 19,933 SF REQUIRED BUFFER DISTANCE 50 FEET PROPOSED BUFFER ZONE CALCULATIONS PROPOSED BUFFER AREA 18,194 SF PROPOSED ADDITIONAL AREA ENHANCED (DETENTION POND) 3,348 SF TOTAL PROPOSED BUFFER AREA 21,542 SF PROPOSED BUFFER ZONE CALCULATIONS CONTINUED MINIMUM BUFFER DISTANCE 21 FEET MAXIMUM BUFFER DISTANCE 78 FEET AVERAGE BUFFER DISTANCE 42 FEET BU F F E R Z O N E D I A G R A M LP102010'20'20'40'N O R T H PL A N T I N G D E T A I L S LP501 IR R I G A T I O N P L A N IR-1 IR R I G A T I O N D E T A I L S IR-2