HomeMy WebLinkAboutUNION PARK - FDP240004 - SUBMITTAL DOCUMENTS - ROUND 2 - Electrical PlansT F 600S4 M 600F4 1 2 MDP DAYCARE PANEL "A" PANEL "B" 225F4 225F4 3 4 208/120V, 3PH, 4W, UTILITY TRANSFORMER TO UTILITY PRIMARY DISCONNECT/CT 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 6/17/2024 9:44:56 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - DAYCARE E512 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - DAYCARE 428 MIN. FEEDER AMPS 154020 TOTAL VA (W/ CONTINUOUS) 61884 29% SPARE AVAILABLE 154020 TOTAL VA LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 MISC 112040 1 112040 KITCHEN 0 0.65 0 EQUIP 41980 1 41980 LIGHTING 0 1.25 0 RECEPT 0 NEC 0 LOAD TYPE LOAD IN VA FACTOR DIVERSIFIED LOAD 30/3 SPD 12 4660 E-CU-10 11 4000 E-CU-9 10 4660 E-CU-8 9 4660 E-CU-7 8 4000 E-CU-6 7 4000 E-CU-5 6 4000 E-CU-4 5 4000 E-CU-3 4 4000 E-CU-2 3 4000 E-CU-1 2 225/3 66400 PANEL B 1 225/3 45640 PANEL A CKT # O/C REMARKS LOAD VA DESCRIPTION BREAKER DISTRIBUTION 100% NEUTRAL XXXXX MINIMUM AIC RATING FULLY RATED 600 AMP MCB INTEGRAL SPD 208/120V 3 PHASE 4 WIRE W/ GND BAR 80% MAIN DISTRIBUTION PANEL MDP-DAYCARE LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 14353 C-PHASE LOAD MISC 0 1 0 15634 B-PHASE LOAD KITCHEN 0 0.65 0 12938 A-PHASE LOAD EQUIP 13795 1 13795 106 MIN. FEEDER AMPS LIGHTING 8560 1.25 10700 38311 VA (W/ CONTINUOUS) RECEPT 20570 NEC 15285 42653 52.7% SPARE LOAD TYPE LOAD IN VA FACTOR DIV LOAD 37640 TOTAL VA SECURITY PANEL 250 20/1 59 C 60 * 600 * INTERCOM SYSTEM 250 20/1 57 B 58 15/2 600 E-ERV-4 E-RECEPTION FRIDGE 750 GFCI 20/1 55 A 56 SPARE R-RECEPTION 1080 20/1 53 C 54 20/1 GFCI 1200 E-COMMERCIAL DISHWASHER R-POFFICE 900 20/1 51 B 52 * 2300 * E-ELECTRIC WATER COOLER 500 GFCI 20/1 49 A 50 30/2 GFCI 2300 E-COMMERCIAL OVEN R-RESOURCE 540 20/1 47 C 48 20/1 360 R-SECURITY RACK R-TELEPHONE BOARD 360 20/1 45 B 46 20/1 540 R-KITCHEN RECEPTS E-IRRIGATION CONTROLLER 100 20/1 43 A 44 20/1 540 R-KITCHEN RECEPTS R-LAUNDRY/SPRINKLER RM 540 20/1 41 C 42 20/1 1150 L-SITE LIGHTING E-FRIDGE 775 GFCI 20/1 39 B 40 20/1 481 L-CLASSROOM/TOILET L-CLASSROOM LTG 750 20/1 37 A 38 20/1 316 L-GALLEY/STOR. E-FRIDGE 770 GFCI 20/1 35 C 36 20/1 738 L-CLASSRM/OFFICE/TOILET R-CLASSROOM RECEPT 775 20/1 33 B 34 20/1 720 R-CLASSROOM RECEPT R-GALLERY/ELEC. 1080 20/1 31 A 32 20/1 540 R-CLASSROOM RECEPT R-CLASSROOM RECEPT 1125 20/1 29 C 30 20/1 900 R-CLASSROOM RECEPT SPARE 720 20/1 27 B 28 20/1 720 R-OFFICE L-CLASSROOM LTG 950 20/1 25 A 26 20/1 500 E-ELECTRIC WATER COOLER L-CLASSROOM LTG 950 20/1 23 C 24 20/1 540 R-CLASSROOM RECEPT L-CLASSROOM LTG 468 20/1 21 B 22 20/1 720 R-CLASSROOM RECEPT L-CLASSROOM LTG 525 20/1 19 A 20 20/1 540 R-STAFF 205 L-CLASSROOM LTG 682 20/1 17 C 18 20/1 900 R-CLASSROOM RECEPT L-CLASSROOM LTG 986 20/1 15 B 16 20/1 720 R-CLASSROOM RECEPT SPARE 20/1 13 A 14 20/1 720 R-CLASSROOM RECEPT L-CLASSROOM LTG 772 20/1 11 C 12 20/1 540 R-CLASSROOM RECEPT L-CLASSROOM LTG 784 20/1 9 B 10 20/1 GFCI 1080 R-VESTABULE RECEPTS L-GALLERY/VESTIBULE LTG 490 20/1 7 A 8 20/1 720 R-CLASSROOM RECEPT L-CONF RM/MECH/ELEC/STAIR 216 20/1 5 C 6 20/1 GFCI 500 E-ICE MAKER L-CLASSROOM LTG 535 20/1 3 B 4 20/1 GFCI 1200 E-FREEZER L-CLASSROOM LTG 417 20/1 1 A 2 20/1 GFCI 1200 E- FRIDGE DESCRIPTION LOAD VA REMARKS O/C CKT # PH CKT # O/C REMARKS LOAD VA DESCRIPTION 60 POLES ONE SECTION 10000 MINIMUM AIC RATING FULLY RATED 225 AMP MLO 100% NEUTRAL 208/120V 3 PHASE 4 WIRE W/ GND BAR SURFACE MOUNTED PANELA LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 13010 C-PHASE LOAD MISC 0 1 0 12960 B-PHASE LOAD KITCHEN 0 0.65 0 16665 A-PHASE LOAD EQUIP 42635 1 42635 118 MIN. FEEDER AMPS LIGHTING 0 1.25 0 42635 VA (W/ CONTINUOUS) RECEPT 0 NEC 0 38329 47.3% SPARE LOAD TYPE LOAD IN VA FACTOR DIV LOAD 42635 TOTAL VA E-CP-2 60 20/1 41 C 42 20/1 SPARE E-CP-1 60 20/1 39 B 40 * 600 * E-SP-1 500 20/1 37 A 38 15/2 600 E-ERV-3 E-WH-2 600 20/1 35 C 36 * 600 * E-WH-1 600 20/1 33 B 34 15/2 600 E-ERV-2 E-EF-2 165 20/1 31 A 32 * 600 * E-EF-1 250 20/1 29 C 30 15/2 600 E-ERV-1 *1100 *27 B 28 15/1 SPARE E-EUH-2 1100 GFCI 30/2 25 A 26 15/1 SPARE *1500 *23 C 24 15/1 SPARE E-EUH-1 1500 GFCI 30/2 21 B 22 15/1 SPARE *1600 *19 A 20 15/1 1700 E-FURN-10 E-DRYER 1600 GFCI 30/2 17 C 18 15/1 1300 E-FURN-9 E-WASHER 1000 GFCI 20/1 15 B 16 15/1 1700 E-FURN-8 *1600 *13 A 14 15/1 1700 E-FURN-7 E-DRYER 1600 GFCI 30/2 11 C 12 15/1 1300 E-FURN-6 E-WASHER 1000 GFCI 20/1 9 B 10 15/1 1300 E-FURN-5 *2300 *7 A 8 15/1 1300 E-FURN-4 E-COMMERCIAL OVEN 2300 GFCI 30/2 5 C 6 15/1 1300 E-FURN-3 *2200 *3 B 4 15/1 1300 E-FURN-2 E-COMMERCIAL MICROWAVE 2200 GFCI 30/2 1 A 2 15/1 1300 E-FURN-1 DESCRIPTION LOAD VA REMARKS O/C CKT # PH CKT # O/C REMARKS LOAD VA DESCRIPTION 42 POLES ONE SECTION 10000 MINIMUM AIC RATING FULLY RATED 225 AMP MLO 100% NEUTRAL 208/120V 3 PHASE 4 WIRE W/ GND BAR SURFACE MOUNTED PANELB ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 3. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 2. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 600 600S4 2 2 1/2" (4)350 KCM N/A 600 600S4 2 3 1/2" (4)500 KCM N/A 600 600F4 2 2 1/2" (4)350 KCM (1)#1 600 600F4 2 3 1/2" (4)500 KCM (1)#2/0 AL 225 225F4 1 2 1/2" (4)#4/0 (1)#4 225 225F4 1 2" (4)300 KCM (1)#2 AL 100 100F4 1 1 1/2" (4)#1 (1)#6 100 100F4 1 1 1/2" (4)#1/0 (1)#4 AL OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE PANEL "HPL1" PANEL "TENANT A" M M T F 400/3 30 / 3 60 / 3 10 0 / 3 10 0 / 3 10 0 / 3 400S4 60F4 60F4 SPD 1 2 3 4 M 5 M 6 PANEL "TENANT B" PANEL "TENANT C" 100F4 100F4 100F4 100F4 100F4 100F4 10 0 / 3 M 7 PANEL "TENANT C" 100F4 100F4 10 0 / 3 10 0 / 3 M 208/120V, 3PH, 4W, UTILITY TRANSFORMER "MSB" 400A, 208/120V, 3PH, 4W, 65KAIC, NEMA 3R 1 2 3 4 TO UTILITY PRIMARY 5 6 7 SOLAR KEY NOTES: 2. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 3. PV CONNECTION BY PV CONTRACTOR. 4. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 5. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # PV PANEL / ARRAY 2 PV STORAGE 3 4 3 5 ROOF 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 6/17/2024 9:44:56 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - MIXED-USE E513 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - MIXED-USE ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 400A 1/0BJ 8BJ 6GEC 1/0GEC 4GEC 1/0GEC 1/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 295 MIN. FEEDER AMPS 106140 TOTAL VA (W/ CONTINUOUS) 37796 26% SPARE AVAILABLE 106140 TOTAL VA LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 MISC 106140 1 106140 KITCHEN 0 0.65 0 EQUIP 0 1 0 LIGHTING 0 1.25 0 RECEPT 0 NEC 0 LOAD TYPE LOAD IN VA FACTOR DIVERSIFIED LOAD 30/3 SPD 6 FUTURE SOLAR 5 100/3 24660 TENANT 4 4 100/3 24660 TENANT 3 3 100/3 24660 TENANT 2 2 100/3 24660 TENANT 1 1 60/3 7500 HOUSE PANEL CKT # O/C REMARKS LOAD VA DESCRIPTION BREAKER DISTRIBUTION 100% NEUTRAL XXXXX MINIMUM AIC RATING FULLY RATED 400 AMP MCB INTEGRAL SPD 208/120V 3 PHASE 4 WIRE W/ GND BAR 80% MAIN DISTRIBUTION PANEL MDP-MIXED USE 3. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 2. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 400 400S4 2 2" (4)#3/0 N/A 400 400S4 2 2 1/2" (4)250 KCM N/A 400 400F4 2 2" (4)#3/0 (1)#3 400 400F4 2 2 1/2" (4)250 KCM (1)#1 AL 100 100F4 1 1 1/2" (4)#1 (1)#6 100 100F4 1 1 1/2" (4)#1/0 (1)#4 AL OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE PANEL "HPL1" PANEL "TENANT A" M M T F 800/3 30 / 3 60 / 3 20 0 / 3 20 0 / 3 20 0 / 3 800S4 60F4 200F4 60F4 200F4 SPD 1 2 3 4 M 200F4 200F4 5 M 200F4 200F4 6 PANEL "TENANT B" PANEL "TENANT C" 20 0 / 3 M 200F4 200F4 7 PANEL "TENANT D" 208/120V, 3PH, 4W, UTILITY TRANSFORMER "MSB" 800A, 208/120V, 3PH, 4W, 65KAIC, NEMA 3R 1 2 3 4 TO UTILITY PRIMARY 5 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 6/17/2024 9:44:57 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - SMALL OFFICE E514 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - SMALL OFFICE 3. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 2. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 800 800S4 3 2 1/2" (4)300 KCM N/A 800 800S4 3 3" (4)400 KCM N/A 800 800F4 3 2 1/2" (4)300 KCM (1)#1/0 800 800F4 3 3" (4)400 KCM (1)#3/0 AL 200 200F4 1 2" (4)#3/0 (1)#6 200 200F4 1 2" (4)250 KCM (1)#4 AL 60 60F4 1 1 1/4" (4)#6 (1)#8 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 800A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 538 MIN. FEEDER AMPS 193520 TOTAL VA (W/ CONTINUOUS) 94352 33% SPARE AVAILABLE 193520 TOTAL VA LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 MISC 193520 1 193520 KITCHEN 0 0.65 0 EQUIP 0 1 0 LIGHTING 0 1.25 0 RECEPT 0 NEC 0 LOAD TYPE LOAD IN VA FACTOR DIVERSIFIED LOAD 30/3 SPD 5 200/3 45700 TENANT D 4 200/3 46420 TENANT C 3 200/3 45700 TENANT B 2 200/3 45700 TENANT A 1 60/3 10000 HOUSE PANEL CKT # O/C REMARKS LOAD VA DESCRIPTION BREAKER DISTRIBUTION 100% NEUTRAL XXXXX MINIMUM AIC RATING FULLY RATED 800 AMP MCB INTEGRAL SPD 208/120V 3 PHASE 4 WIRE W/ GND BAR 80% MAIN DISTRIBUTION PANEL MDP-OFFICESM PANEL "HPL1" PANEL "TENANT A" M M T F 1200/3 30 / 3 10 0 / 3 20 0 / 3 20 0 / 3 20 0 / 3 20 0 / 3 20 0 / 3 20 0 / 3 1200S4 100F4 200F4 100F4 200F4 SPD 1 2 3 4 M 200F4 200F4 5 M 200F4 200F4 6 M 200F4 200F4 7 M 200F4 200F4 8 M 200F4 200F4 9 PANEL "TENANT B" PANEL "TENANT C" PANEL "TENANT D" PANEL "TENANT E" PANEL "TENANT F" 208/120V, 3PH, 4W, UTILITY TRANSFORMER "MSB" 1200A, 208/120V, 3PH, 4W, 65KAIC, NEMA 3R 1 2 3 4 5 6 7 TO UTILITY PRIMARY 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 6/17/2024 9:44:58 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - LARGE OFFICE E515 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - LARGE OFFICE 3. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 2. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 1200 1200S4 4 2 1/2" (4)350 KCM N/A 1200 1200S4 4 3 1/2" (4)500 KCM N/A 1200 1200F4 4 2 1/2" (4)350 KCM (1)#3/0 1200 1200F4 4 3 1/2"(4)500 KCM (1)250 KCM AL 200 200F4 1 2" (4)#3/0 (1)#6 200 200F4 1 2" (4)250 KCM (1)#4 AL 100 100F4 1 1 1/2" (4)#1 (1)#6 100 100F4 1 1 1/2" (4)#1/0 (1)#4 AL OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE 950 MIN. FEEDER AMPS 341680 TOTAL VA (W/ CONTINUOUS) 90128 21% SPARE AVAILABLE 341680 TOTAL VA LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 MISC 341680 1 341680 KITCHEN 0 0.65 0 EQUIP 0 1 0 LIGHTING 0 1.25 0 RECEPT 0 NEC 0 LOAD TYPE LOAD IN VA FACTOR DIVERSIFIED LOAD 30/3 SPD 7 200/3 46300 TENANT F 6 200/3 66400 TENANT E 5 200/3 45640 TENANT D 4 200/3 46300 TENANT C 3 200/3 66400 TENANT B 2 200/3 45640 TENANT A 1 100/3 25000 HOUSE PANEL CKT # O/C REMARKS LOAD VA DESCRIPTION BREAKER DISTRIBUTION 100% NEUTRAL XXXXX MINIMUM AIC RATING FULLY RATED 1200 AMP MCB INTEGRAL SPD 208/120V 3 PHASE 4 WIRE W/ GND BAR 80% MAIN DISTRIBUTION PANEL MDP-OFFICELG ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 1200A 4/0BJ 8BJ 6GEC 3/0GEC 4GEC 3/0GEC 3/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE