Loading...
HomeMy WebLinkAboutSNOW RIDGE APARTMENTS - FDP240003 - SUBMITTAL DOCUMENTS - ROUND 2 - Site, Landscape & Elevations PlansDRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 1 C o v e r Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 2 A M Fi l e N a m e : 1 C o v e r . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com COVER FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 1 OF 17 NORTH SNOW RIDGE APARTMENTS VICINITY MAP SCALE: NTS LAND USE CHART EXISTING ZONING N-C-B GROSS AREA (SF)% RESIDENTIAL BUILDING COVERAGE 4,450 15.26 DRIVES AND PARKING (EXCLUDES PUBLIC ROW)7,503 25.73 OPEN SPACE AND LANDSCAPE (EXCLUDES PUBLIC ROW)12,874 44.16 HARDSCAPE (EXCLUDES PUBLIC ROW)3,731 12.80 PUBLIC STREET RIGHT-OF-WAY 597 2.05 HARDSCAPE 57 DRIVES AND PARKING 34 LANDSCAPE 506 TOTAL GROSS COVERAGE 29,155.00 SF (0.67 AC)100 AREA COVERAGE NET AREA (SF)% BUILDING COVERAGE 4,450 15.58 DRIVES AND PARKING 7,503 26.27 OPEN SPACE AND LANDSCAPE 12,874 45.08 HARDSCAPE (WALKS & PLAZAS)3,731 13.06 TOTAL NET COVERAGE 28,558.00 SF (0.66 AC)100 BICYCLE PARKING REQUIREMENTS PROVIDED REQUIRED * MULTIFAMILY ENCLOSED SPACES 8 8 SURFACE MOUNTED EXTERIOR SPACES 6 6 TOTAL 14 14 * REQUIRED BICYCLE SPACES ARE CALCULATED AS FOLLOWED FOR MULTIFAMILY: 14 BEDROOMS X 1 SPACE = 14 SPACES. 60% REQUIRED TO BE ENCLOSED, 40% FIXED. Director Signature PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF ________, 20__. SITE PLAN NOTES 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12.THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 13.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 14.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 15.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. LEGAL DESCRPTION DENSITY GROSS GROSS AREA 29,155 (0.67 AC) TOTAL DWELLING UNITS 8 GROSS DENSITY 11.94 DU/AC NET (EXCLUDING PUBLIC R.O.W.) NET AREA 28,558 SF (0.66 AC) TOTAL DWELLING UNITS 8 NET DENSITY 12.12 DU/AC PROVIDED PARKING TOTAL TOTAL % MULTIFAMILY LONG-TERM SPACES 7 88 ADA PARKING SPACES 1 13 TOTAL PROVIDED 8 100 * RIGHT OF WAY TO BE DEDICATED FOR PUBLIC ROAD: 597 S.F. / 0.01 ACRE SH I E L D S S T R E E T SPRINGFIELD DRIVE W. PITKIN STREET W. PROSPECT ROAD SHEET INDEX OWNER (SIGNED)Date THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS THIS DAY OF MY COMMISSION EXPIRES: AS . (PRINT NAME) 20 .A.D., BY THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER'S CERTIFICATE SITE LOT 1, SNOW RIDGE SUBDIVISION IN THE CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. REQUIRED PARKING (WITHIN THE T.O.D. OVERLAY ZONE) 3.2.2.k.2 TOTAL BEDS PARKING REQUIRED (SPACES) 1-BED 2-BED 3-BED 1-BED 2-BED 3-BED TOTAL PARKING REQ. MULTIFAMILY BUILDING 3 4 1 2 4 1.25 7.25 REQUIRED PARKING 8 TOTAL 8 Sheet Number Sheet Title 1 Cover 2 Site Plan 3 Overall Landscape 4 Landscape notes & Schedule 5 Landscape Details 6 Hydrozone Plan 7 Tree Mitigation Plan 8 Allowable Floor Area Exhibit 9 Multifamily Building Elevations 10 Building Elevations, Trash Enclosure Plan & Elevations & Bike Storage 11 Perspectives and Color Board E0.0 Fort Collins Lighting Code E1.0 Photometric Fixture Cut-Sheets IR1.0 Irrigation Design IR1.1 Irrigation Design IR2.1 Irrigation Details IR2.2 Irrigation Specifications FO FO FO FO FO FO OH U OH U OH U OH U OHU OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OHU OHU OHU OHU OHU OHU OHU G G FO FO FO FO FO FO FO FO E E E E E E E E E E E E E EM GM EEEEEEEEEE E WWWWWWWWWWWW W W G G G G G G G G G G G G SSSSSSSSSSSSSSSSSSSSSSSSSS UD UD UD UD UD UD UD UD UD UD UD E WWWW W WWWWWWWW W S WF R8'-0" 4 4 PARCEL 9715418001 OWNER: BYRNE MICHAEL F, CATHERINE NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PARCEL 9715418004 OWNER: RHT LLC NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PA R C E L 9 7 1 5 4 1 8 0 1 0 O W N E R : M I L L E R J E R A L D B Y R O N / N O R M A R O S A R I O LO W D E N S I T Y M I X E D - U S E N E I G H B O R H O O D D I S T R I C T EXISTING BUILDING (2) 2 BR UNITS) ADDITION (MAIL & BIKE STORAGE) MULTIFAMILY ADDITION ((2) 1 BR UNITS) MULTIFAMILY ADDITION ((2) 2 BR UNITS) MULTIFAMILY ADDITION (2) 2 BR UNITS PROPERTY BOUNDARY PROPERTY BOUNDARY S. S H I E L D S S T R E E T 8'-6" 19'-0" 8'-6" 20'-0" EMERGENCY ACCESS EASEMENT 8'-0" 6'-0" WALK 19'-0" TRASH AND RECYCLING ENCLOSURE, RE: ARCH PRIMARY ENTRANCE WITH PORCH 6'-0" WALK VAN ACCESSIBLE SPACE DOWNSPOUT, TYP. ADA RAMP DRAIN PAN, TYP. RE: CIVIL 6'-0" WALK CHASE, TYP. RE: CIVIL 15'-0" REAR YARD SETBACK 60'-0" FRONT YARD SETBACK 10'-10" FIRE RISER ROOM EXISTING FENCE TO BE REMOVED TELEPHONE POLE 6'-3" 27'-8" 64'-5" EXISTING TELECOM VAULT LIGHT POLE, RE: PHOTOMETRIC 6'-0" WALK 3'-0" EXISTING WALK 15'-0" UTILITY EASEMENT 10'-0" OVERHEAD UTILITY EASEMENT ADA PARKING SIGN, RE: CIVIL ADA RAMP CRITICAL ROOT ZONE, TYP. 8'-0" 5'-0" SIDE YARD SETBACK CONCRETE LANDING PAD PROPOSED PAD MOUNTED TRANSFORMER, RE: CIVIL SIGN, RE: CIVIL 6'-0" WALK SIGN, RE: CIVIL RIGHT OF WAY DRAINAGE EASEMENT TELEPHONE PEDESTAL EXISTING ELECTRIC VAULT EXISTING WELL LOCATION 6'-0" WALK (+/-480 SF) COMMON AMENITY SPACE 77'-5" 6'-0" WALK 6'-0" WALK 5'-0" SIDE YARD SETBACK 8'-0" 8'-6" 20'-0" 5 5 CEDAR PRIVACY FENCE 6 5 SURFACE MOUNT BIKE RACK 3'-9" SIGN, RE: CIVIL SIGN, RE: CIVIL 9 5 BOULDER WALL 7 5 AMENITY PAVERS AND ADJACENCIES 2'-0" SIGN, RE: CIVIL RIGHT OF WAY LINE NEW WELL LOCATION LIGHT POLE, RE: PHOTOMETRIC MAINTENANCE SHED, SIZE TO BE DETERMINED IN FIELD PER PUMP REQUIREMENTS; SHED SHALL NOT EXCEED 8' IN HEIGHT. PERMEABLE PAVERS, RE: CIVIL PERMEABLE PAVERS, RE: CIVIL SS G E W FO X UD W G SS E = EXISTING SANITARY SEWER = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = PROJECT BOUNDARY = LOT LINE = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = EXISTING STORMWATER UTILITY = PARKING STALL COUNT = PROPOSED GRADING = TRANSFORMER, TYP. OHU = EXISTING OVER HEAD UTILITY # DESCRIPTION ENHANCED PAVING CONCRETE PAVING DRIVES AND PARKING BUILDING OVERHANG PROPOSED SCREEN FENCE EXISTING TREE TO REMAIN ENTRANCE TO BUILDING SITE LIGHTS, RE: PHOTOMETRIC PLAN = A/C CONDENSER DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 2 S i t e P l a n Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 2 A M Fi l e N a m e : 2 S i t e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER SITE PLAN FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 2 OF 17 NORTH 0 05 10 20 SCALE: 1"=10'-0" LEGEND EM GM EEEEEEEEEE E WWWWWWWWWWWW W W G G G G G G G G G G G G SSSSSSSSSSSSSSSSSSSSSSSSSS UD UD UD UD UD UD UD UD UD UD UD E WWW W WWWWWWWW W S WF MBMBMB FO FO FO FO FO FO OH U OH U OHU OHU OHU OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OHU OHU OHU OHU OHU OHU OHU G FO FO FO FO FO FO FO E E E E E E E E E E E E E PARCEL 9715418001 OWNER: BYRNE MICHAEL F, CATHERINE NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PARCEL 9715418004 OWNER: RHT LLC NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PA R C E L 9 7 1 5 4 1 8 0 1 0 O W N E R : M I L L E R J E R A L D B Y R O N / N O R M A R O S A R I O LO W D E N S I T Y M I X E D - U S E N E I G H B O R H O O D D I S T R I C T EXISTING BUILDING (2) 2 BR UNITS) ADDITION (MAIL & BIKE STORAGE) MULTIFAMILY ADDITION ((2) 1 BR UNITS) MULTIFAMILY ADDITION ((2) 2 BR UNITS) MULTIFAMILY ADDITION (2) 2 BR UNITS PROPERTY BOUNDARY PROPERTY BOUNDARY S. S H I E L D S S T R E E T 1 - TAM 3 - PCE 1 - GTR 1 - CCO 5 - JSC 5 - JSB 5 - JCH 5 - JSC 1 - PVC 2 - PPI 6 - PFG 3 - SBL 1 - SBL 3 - PFG 3 - PFG 1 - PPI 1 - PPI 7 - SSP 7 - SSP 5 - CAK 5 - CAK 7 - HHA 10 - CLA 3 - HPB 6 - HPB 8 - CLA 5 - PFG 2 - SBL 10 - PFG 2 - SPE 6 - PAB 7 - SSI 6 - PAB 9 - PAB 6 - PAB 1 - DTB 14 - CLA 6 - BTS 5 - CLA 6 - CLA 5 - CAK 5 - CAK 7 - SSP 7 - SSP 8 - PAB 8 - PAB 3 - HPB 4 - HHA 9 - CLA5 - HHA 4 - SSP 21 - PAB 4 - JCH 1 - SPE 4 - CLA 9 - HHA 5 - HPB 3 - HPB 4 - PAB 3 - CAK 4 - SSP 3 - HPB 3 - HPB 11 - CLA 5 - CLA 10 - HHA 5 - CAK 5 - CAK 12 - HHA 8 - HHA 7 - CAK 1 - PVC 5 - HHA 11 - CLA 8 - SSP 11 - SSP 7 - CLA 2 - VTB 7 - SSP 7 - SSP 7 - CLA 16 - PAB 1 - PPI 5 - SSP 6 - HPB 2 - DTB 1 - DTB 1 - DTB 5 - SS 2 - HPB 11 - ARU 5 - ARU 5 - JSW 1 - TAM M M M M M M M M M M M M M M MM M 17 - CAK 4 - CLA 2 - JSW 3 - RRA 3 - HPB 5 - OSA 5 - AAG 4 - OSA 5 - AAG 3 - DTB 5 - DTB EXISTING TREE TO REMAIN CRITICAL ROOT ZONE, TYP. DOWNSPOUTS, TYP. RE: ARCH BOULDER WALL, TYP. PROPOSED PAD MOUNTED TRANSFORMER, RE: CIVIL SS G E W FO X UD W G SS E = EXISTING SANITARY SEWER = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = PROJECT BOUNDARY = LOT LINE = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = EXISTING STORMWATER UTILITY = PROPOSED GRADING = TRANSFORMER, TYP. WOOD MULCH IRRIGATED TURF COBBLE MULCH 20 PERCENT 4"-8" WASHED RIVER ROCK WITHIN 1'-2' EITHER SIDE OF DRAIN PAN 20 PERCENT 2"-4" WASHED RIVER ROCK 1'-2' OUTSIDE OF LARGER ROCK THE REMAINDER TO BE 1 1/2" PIONEER BLUE DECOARTIVE ROCK NATIVE SEED MIX FOR RAIN GARDENS CRUSHED FINES CODE QTY COMMON NAME CANOPY TREES CCO 1 TURKISH FILBERT GTR 1 SKYLINE HONEY LOCUST TAM 2 REDMOND AMERICAN LINDEN EVERGREEN TREES PPI 5 COLUMNAR COLORADO BLUE SPRUCE ORNAMENTAL TREES PCE 3 COLUMNAR PURPLE PLUM PVC 2 CANADA RED CHOKECHERRY SPE 3 PEKING LILAC CODE QTY COMMON NAME DECIDUOUS SHRUBS BTS 6 SPARKLE JAPANESE BARBERRY DTB 13 ETERNAL FRAGRANCE DAPHNE HPB 37 BOBO® PANICLE HYDRANGEA PFG 27 GOLD DROP BUSH CINQUEFOIL RRA 3 DOUBLE KNOCK OUT® RED ROSE SS 5 GOLDMOUND SPIREA SBL 6 BLOOMERANG SERIES LILAC VTB 2 BAILEY'S COMPACT CRANBERRYBUSH EVERGREEN SHRUBS JCH 9 HETZI COLUMN JUNIPER JSB 5 BLUE ARROW JUNIPER JSC 10 SKYROCKET JUNIPER JSW 7 WOODWARD COLUMNAR JUNIPER ORNAMENTAL GRASSES CAK 57 KARL FOERSTER FEATHER REED GRASS CLA 101 NORTHERN SEA OATS PAB 84 LITTLE BUNNY FOUNTAIN GRASS SSP 74 PRAIRIE BLUES LITTLE BLUESTEM PERENNIALS ARU 16 THREADLEAF HYSSOP AAG 10 GOLIATH ALPINE ASTER HHA 60 HAPPY RETURNS DAYLILY OSA 9 AVALANCHE WHITE SUN DAISY SSI 7 MT. ALBERT GOLDENROD = COMMON ENTRANCE TO MULTIFAMILY BUILDING = A/C CONDENSER DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 3 O v e r a l l L a n d s c a p e Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 3 A M Fi l e N a m e : 3 O v e r a l l L a n d s c a p e . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER OVERALL LANDSCAPE FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 3 OF 17 NORTH 0 05 10 20 SCALE: 1"=10'-0" A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 1.ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR A NESTING SURVEY WILL BE CONDUCTED BY A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST PRIOR TO TREE REMOVAL TO ENSURE THAT NO ACTIVE NESTS ARE PRESENT. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. LANDSCAPE PLAN NOTELEGENDPLANTING SCHEDULE NOTE: REFER TO SHEET 4 FOR FULL PLANTING SCHEDULE. 10-19 TREES ≤ 50%COUNT TYPE (PROPOSED AND EXISTING TO REMAIN) CANOPY TREES 23.5 4 5.9%1 CORYLUS COLURNA / TURKISH FILBERT 5.9%1 GLEDITSIA TRIACANTHOS INERMIS 'SKYLINE' / SKYLINE HONEY LOCUST 11.8%2 TILIA AMERICANA 'REDMOND' / REDMOND AMERICAN LINDEN EVERGREEN TREES 29.4 5 29.4%5 PICEA PUNGENS 'ISELI FASTIGIATA' / COLUMNAR COLORADO BLUE SPRUCE ORNAMENTAL TREES 47.1 8 17.6%3 PRUNUS CERASIFERA CRIMSON POINTE / COLUMNAR PURPLE PLUM 11.8%2 PRUNUS VIRGINIANA 'SHUBERT' / CANADA RED CHOKECHERRY 17.6%3 SYRINGA PEKINENSIS / PEKING LILAC TOTAL 100 17 PER CITY OF FORT COLLINS 3.2.1(D)3 PROPOSED PLAN MUST HAVE A SPECIES DIVERSITY OF (10-19 TREES < 50%, 20-39 TREES < 33%, 40-59 TREES < 25%, 60+ TREES < 15%). OF THE 18 TOTAL TREES PROPOSED ON SITE, NO SPECIES MAY HAVE MORE THAN 3 QUANTITY. SYMBOL CODE QTY BOTANICAL / COMMON NAME CONT CAL SIZE CANOPY TREES CCO 1 CORYLUS COLURNA / TURKISH FILBERT B & B 2"CAL GTR 1 GLEDITSIA TRIACANTHOS INERMIS 'SKYLINE' / SKYLINE HONEY LOCUST B & B 2"CAL TAM 2 TILIA AMERICANA 'REDMOND' / REDMOND AMERICAN LINDEN B & B 2"CAL EVERGREEN TREES PPI 5 PICEA PUNGENS `ISELI FASTIGIATA` / COLUMNAR COLORADO BLUE SPRUCE B & B 8`HT ORNAMENTAL TREES PCE 3 PRUNUS CERASIFERA CRIMSON POINTE / COLUMNAR PURPLE PLUM B & B 2"CAL PVC 2 PRUNUS VIRGINIANA `SHUBERT' / CANADA RED CHOKECHERRY B & B 2"CAL SPE 3 SYRINGA PEKINENSIS / PEKING LILAC B & B 2"CAL SYMBOL CODE QTY BOTANICAL / COMMON NAME SIZE HYDROZONE DECIDUOUS SHRUBS BTS 6 BERBERIS THUNBERGII 'SPARKLE' / SPARKLE JAPANESE BARBERRY 5 GAL DTB 13 DAPHNE X TRANSATLANTICA 'BLAFRA' / ETERNAL FRAGRANCE DAPHNE 5 GAL HPB 37 HYDRANGEA PANICULATA 'ILVOBO' / BOBO® PANICLE HYDRANGEA 5 GAL PFG 27 POTENTILLA FRUTICOSA 'GOLD DROP' / GOLD DROP BUSH CINQUEFOIL 5 GAL RRA 3 ROSA X 'RADTKO' / DOUBLE KNOCK OUT® RED ROSE 5 GAL SS 5 SPIRAEA X 'GOLDMOUND' / GOLDMOUND SPIREA 5 GAL SBL 6 SYRINGA X 'BLOOMERANG' / BLOOMERANG SERIES LILAC 5 GAL VTB 2 VIBURNUM TRILOBUM 'BAILEY COMPACT' / BAILEY'S COMPACT CRANBERRYBUSH 5 GAL EVERGREEN SHRUBS JCH 9 JUNIPERUS CHINENSIS 'HETZII COLUMNARIS' / HETZI COLUMN JUNIPER 6` HT JSB 5 JUNIPERUS SCOPULORUM 'BLUE ARROW' / BLUE ARROW JUNIPER 6` HT JSC 10 JUNIPERUS SCOPULORUM 'SKYROCKET' / SKYROCKET JUNIPER 6` HT JSW 7 JUNIPERUS SCOPULORUM 'WOODWARD' / WOODWARD COLUMNAR JUNIPER 6` HT ORNAMENTAL GRASSES CAK 57 CALAMAGROSTIS X ACUTIFLORA 'KARL FOERSTER' / KARL FOERSTER FEATHER REED GRASS 1 GAL CLA 101 CHASMANTHIUM LATIFOLIUM / NORTHERN SEA OATS 1 GAL PAB 84 PENNISETUM ALOPECUROIDES 'LITTLE BUNNY' / LITTLE BUNNY FOUNTAIN GRASS 1 GAL SSP 74 SCHIZACHYRIUM SCOPARIUM 'PRAIRIE BLUES' / PRAIRIE BLUES LITTLE BLUESTEM 1 GAL PERENNIALS ARU 16 AGASTACHE RUPESTRIS / THREADLEAF HYSSOP 1 GAL AAG 10 ASTER ALPINUS 'GOLIATH' / GOLIATH ALPINE ASTER 1 GAL HHA 60 HEMEROCALLIS X `HAPPY RETURNS` / HAPPY RETURNS DAYLILY 1 GAL OSA 9 OSTEOSPERMUM X 'AVALANCHE' / AVALANCHE WHITE SUN DAISY 1 GAL SSI 7 SOLIDAGO SIMPLEX / MT. ALBERT GOLDENROD 1 GAL DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 5 L a n d s c a p e n o t e s & S c h e d u l e Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 3 A M Fi l e N a m e : 5 L a n d s c a p e n o t e s & S c h e d u l e . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER LANDSCAPE NOTES & SCHEDULE FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 4 OF 17 1.PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT. 2.IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. 3.TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4.SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOROUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5.INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6.MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7.REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8.THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS 15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES 4 FEET BETWEEN TREES AND GAS LINES 9.ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). 10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. 11.THE DEVELOPER SHALL ENSURE THAT THE FINAL LANDSCAPE PLAN IS COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN. 12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION. 13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES. 14.IRRIGATED TURF SHALL BE HYPER BLUE BLUEGRASS SEED BY GRAFF'S TURF OR APPROVED EQUAL. 15.EDGING BETWEEN GRASS AND SHRUB BEDS SHALL BE 18" X 4" ROLLED TOP STEEL SET LEVEL WITH TOP OF SOD OR APPROVED EQUAL. 16.THE DEVELOPER, OR ITS SUCCESSOR(S) IN INTEREST, SHALL BE RESPONSIBLE FOR THE ONGOING IRRIGATION AND MAINTENANCE OF THE LANDSCAPING LOCATED WITHIN THE PUBLIC RIGHT OF WAY ALONG THE PORTION OF S. SHIELDS STREETS THAT ABUTS THE PROPERTY AS SHOWN ON THESE FINAL DEVELOPMENT PLAN DOCUMENTS. THIS OBLIGATION MAY BE ASSIGNED TO A HOMEOWNERS ASSOCIATION DULY CONSTITUTED PURSUANT TO COLORADO STATE LAW, HOWEVER, SHOULD SUCH HOME OWNERS ASSOCIATION BE DISSOLVED, THE OBLIGATION SHALL BECOME THAT OF THE DEVELOPER OR ITS SUCCESSOR(S) IN INTEREST. GENERAL LANDSCAPE NOTES STREET TREE NOTES 1.A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2.CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3.STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4.THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5.SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE SPECIES DIVERSITY PLANTING SCHEDULE NATIVE SEED MIX FOR RAIN GARDENS DETENTION BASIN MIX COMMON NAME SCIENTIFIC NAME VARIETY LBS/ACRE OF PLS OUNCES PER ACRE SAND BLUESTEM ANDROPOGON HALLII GARDEN 3.5 SIDEOATS GRAMA BOUTELOUA CURTIPENDULA BUTTE 3 PRAIRIE SANDREED CALAMOVILFA LONIFOLIA GOSHEN 3 INDIAN RICEGRASS ORYZOPSIS HYMENOIDES PALOMA 3 SWITCHGRASS PANICUM VIRGATUM BLACKWELL 4 WESTERN WHEATGRASS PASCOPYRUM SMITHII ARIBA 3 LITTLE BLUESTEM SCHIZACHYRIUM SCOPARIUM PATURA 3 ALKALI SACATON SPOROBOLUS AIROIDES 3 SAND DROPSEED SPOROBOLUS CRYPTANDRUS 3 PASTURE SAGE ARTEMISIA FRIGIDA 2 BLUE ASTER ASTER LAEVIS 4 BLANKET FLOWER GAILLARDIA ARISTATA 8 PRAIRIE CONEFLOWER RATIBIDA COLUMNIFERA 4 PURPLE PRAIRIECLOVER DALEA (PETALOSTEMUM) PURPUREA 4 SUB-TOTALS:28.5 22 TOTAL FOR RAIN GARDEN MIX 29.88 * CONTRACTOR TO PROVIDE TEMPORARY IRRIGATION FOR RAIN GARDEN SEED MIX AREAS TO HELP ESTABLISH PLANT MATERIAL. 1.THE TIME OF YEAR SEEDING IS TO OCCUR SHOULD BE OCTOBER THROUGH EARLY MAY. 2.PREPARE SOIL AS NECESSARY AND APPROPRIATE FOR NATIVE SEED MIX SPECIES THROUGH LOOSENING AND ADDITION OF AMENDMENTS THAT PROMOTE WATER ABSORPTION AND RELEASE, THEN SEED IN TWO DIRECTIONS TO DISTRIBUTE SEED EVENLY OVER ENTIRE AREA. DRILL SEED ALL INDICATED AREAS AS SOON AS POSSIBLE AFTER COMPLETION OF GRADING OPERATIONS. 3.IF CHANGES ARE TO BE MADE TO SEED MIX BASED ON SITE CONDITIONS THEN APPROVAL MUST BE PROVIDED BY CITY ENVIRONMENTAL PLANNER. 4.APPROPRIATE NATIVE SEEDING EQUIPMENT WILL BE USED (STANDARD TURF SEEDING EQUIPMENT OR AGRICULTURE EQUIPMENT SHALL NOT BE USED). 5.DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED APPLICATION RATE TO NO MORE THAN ½ INCH DEPTH. FOR BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD DOUBLE SPECIFIED APPLICATION RATE. REFER TO NATIVE SEED MIX TABLE FOR SPECIES, PERCENTAGES AND APPLICATION RATES. 6.PREPARE A WEED MANAGEMENT PLAN TO ENSURE THAT WEEDS ARE PROPERLY MANAGED BEFORE, DURING AND AFTER SEEDING ACTIVITIES. 7.AFTER SEEDING THE AREA SHALL BE COVERED WITH CRIMPED STRAW, JUTE MESH, OR OTHER APPROPRIATE METHODS. PLASTIC BASED EROSION CONTROL MATAERIALS (I.E., PLASTIC WELDED BLANKETS) SHALL NOT BE USED WITHOUT EXPRESS PERMISSION FROM THE ENVIRONMENTAL PLANNER AS THESE MATERIALS HAVE PROVEN TO CAUSE WILDLIFE ENTRAPMENT ISSUES. 8.WHERE NEEDED, TEMPORARY IRRIGATION SHOULD BE PROVIDED UNTIL SEED IS GERMINATED THEN WEEN THE SEED FROM IRRIGATION. IF IRRIGATION IS USED, THE IRRIGATION SYSTEM FOR SEEDED AREAS SHALL BE FULLY OPERATIONAL AT THE TIME OF SEEDING AND SHALL ENSURE 100% HEAD_TO_HEAD COVERAGE OVER ALL SEEDED AREAS. ALL METHODS AND REQUIREMENTS IN THE APPROVED IRRIGATION PLAN SHALL BE FOLLOWED. 9.CONTRACTOR SHALL MONITOR SEEDED AREA FOR PROPER IRRIGATION, EROSION CONTROL, GERMINATION AND RESEEDING AS NEEDED TO ESTABLISH COVER. 10.THE APPROVED NATIVE SEED MIX AREA IS INTENDED TO BE MAINTAINED IN A NATURAL LIKE LANDSCAPE AESTHETIC. DO NOT MOW DURING HOT, DRY PERIODS. DO NOT MOW LOWER THAN 6 TO 8 INCHES IN HEIGHT TO AVOID INHIBITING NATIVE PLANT GROWTH. 11.NATIVE SEED AREA WILL BE CONSIDERED ESTABLISHED WHEN SEVENTY PERCENT VEGETATIVE COVER IS REACHED WITH LESS THAN TEN PERCENT OF COVER CONSISTING OF NOXIOUS WEEDS, NO BARE SPOTS LARGER THAN ONE FOOT SQUARE, AND/OR UNTIL DEEMED ESTABLISHED BY CITY PLANNING SERVICES AND EROSION CONTROL. 12.THE DEVELOPER AND/OR LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR ADEQUATE SEEDLING COVERAGE AND GROWTH AT THE TIME OF FINAL STABILIZATION, AS DEFINED BY STATE AND LOCAL AGENCIES. IF FINAL STABILIZATION IS NOT ACHIEVED TO THE SATISFACTION OF THE AGENCY, THE DEVELOPER AND/OR LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL CORRECTIVE MEASURES TO SATISFY FINAL VEGETATIVE REQUIREMENTS FOR CLOSEOUT. NATIVE SEED MIX NOTES HYPER BLUEGREASS MIX PERCENTAGE VARIETY 30%BEWITCHED 30%WATERWORKS 30%RIDGELINE 10%SPF 30 (TEXAS HYBRID) * CONTRACTOR TO PROVIDE TEMPORARY IRRIGATION FOR RAIN GARDEN SEED MIX AREAS TO HELP ESTABLISH PLANT MATERIAL. DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 6 L a n d s c a p e D e t a i l s Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 3 A M Fi l e N a m e : 6 L a n d s c a p e D e t a i l s . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER LANDSCAPE DETAILS FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 5 OF 17 STAKING NOTES: STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT END OF FIRST GROWING SEASON AS FOLLOWS: 1 1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING WIND. (GENERALLY N.W. SIDE) 1 1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE, ONE ON S.W. SIDE 3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO ACCOMMODATE 1 1/2" OF GROWTH AND BUFFER ALL BRANCHES FROM WIRE GUYING PLAN PLANT SO THAT TOP OF ROOT BALL IS 2" HIGHER THAN FINISHED GRADE GROMMETED NYLON STRAPS GALVANIZED WIRE TWIST TO TIGHTEN 6' STEEL T-POSTS (SEE SCHEDULE) DRIVEN (MIN. 18") FIRMLY INTO UNDISTURBED SOIL OUTSIDE ROOTBALL. SCARIFY SIDES OF PLANTING HOLE LEAVING 1:1 SLOPE BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20% (BY VOL.) ORGANIC MATERIAL TAMP SOIL AROUND ROOT BALL W/ FOOT PRESSURE SO THAT IT DOESN'T SHIFT. WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. PRUNING NOTES: DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN 2 X BALL DIA. P R E V A I L I N G W I N D 4" DEEP MULCH RING PLACED A MINIMUM OF 6' IN DIAMETER. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK ROUND-TOPPED SOIL BERM 3" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. (OMIT IN TURF AREAS) CONIFER TREE PLANTING DETAIL - STEEL POSTS SCALE: NTS REMOVE ALL WIRE, TWINE BURLAP, MESH AND CONTAINERS FROM ENTIRE ROOT BALL AND TRUNK 1 L-PL2-PLA-01 P R E V A I L I N G W I N D PLAN VIEW - THREE STAKES TREE PLANTING DETAIL - STEEL POSTS SCALE: NTS ROUND TOPPED SOIL BERM 3" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. (OMIT IN TURF AREAS) NOTES: SET S0 THAT TOP OF ROOT 1-2" HIGHER THAN FINISHED GRADE MARK NORTH SIDE OF TREE IN NURSERY AND ROTATE TREE TO FACE NORTH AT THE SITE WHENEVER POSSIBLE 2 STRAND 12 GAUGE GAL. WIRE (TWIST TO TIGHTEN) & GROMMETED NYLON STRAPS STEEL T-POSTS DRIVEN (MIN. 18") FIRMLY INTO UNDISTURBED SOIL OUTSIDE OF PLANTING HOLE BEFORE BACKFILLING STAKE ABOVE FIRST BRANCHES OR AS NECESSARY FOR FIRM SUPPORT BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20% (BY VOL.) ORGANIC MATERIAL PLACE FIRMLY BUT DON'T TAMP OR COMPACT AROUND ROOT BALL. WATER WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. REMOVE ALL WIRE, TWINE BURLAP, MESH AND CONTAINERS FROM ENTIRE ROOT BALL AND TRUNK 4" DEEP MULCH RING PLACED A MINIMUM OF 6' IN DIAMETER. 1" MULCH OVER ROOT BALL. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK 2 X BALL DIA. BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL SCARIFY SIDES OF HOLE LEAVING 1:1 SLOPE 2 L-PL2-PLA-12 PRUNING NOTES: DO NOT HEAVILY PRUNE SHRUB AT PLANTING. PRUNE ONLY DEAD OR BROKEN BRANCHES. IF FORM IS COMPROMISED BY PRUNING, REPLACE SHRUB PLACEMENT NOTES: ·SET SHRUB PLUMB. SPACE PLANTS, AND PLACE FOR BEST EFFECT ·SET TOP OF ROOTBALL 1-2" HIGHER THAN ADJACENT GRADE SCARIFY SIDES AND USE 1:1 SLOPE 4" DEEP MULCH RING 3' IN DIA. PLACE ON GEOTEXTILE WEED BARRIER. 1" OF MULCH ON TOP OF ROOT BALL REMOVE CONTAINER (INCLUDING FIBER CONTAINERS), BASKETS, WIRE, ETC. FROM THE ROOT BALL. BREAK UP ENCIRCLING ROOTS WITH SHARP KNIFE OR SPADE. SPLIT BOTTOM OF ROOT BALL. PLACE ON UNDISTURBED SOIL TO PREVENT SETTLEMENT. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. BACKFILL WITH BLEND OF EXISTING SOIL AND A MAX. 20% (BY VOL.) ORGANIC MATERIAL. WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS 2 X BALL DIA. 4" HIGH WATER SAUCER SHRUB PLANTING DETAIL SCALE: NTS3 L-PL2-PLA-14 SURFACE MOUNT BIKE RACK 3/4" = 1'-0" 2" 5'-03 4" 2'-101 4" 77 8"10GA COVER PLATE 3/8" X 6" DIA STL PLATE 5/8" X 1 1/2" S.STL. FLT SKT HD CAP SCR S-2 SURFACE MOUNT (SEE NOTES) NOTES: -1/2" X 3 3/4" EXPANSION ANCHOR BOLTS PROVIDED FOR S-2 OPTION -COATED W/ZINC RICH EPOXY THEN FINISHED W/ POLYESTER POWDER COATING. 6 OP-SS-05 5"X5" CEDAR POST 2"X6" VERTICAL CEDAR PLANK, TYP. PLAN CEDAR PRIVACY FENCE NTS NOTES: 1. FENCE TO BE STAINED; CONTRACTOR TO SUBMIT STAIN SAMPLES TO LANDSCAPE ARCHITECT FOR APPROVAL. 2. BOTTOM RAIL TO INCLUDE REINFORCEMENT. ELEVATION 8'-0" 5'-0" 2"FLAT POST CAP 5 OP-SS-06 AMENITY PAVERS AND ADJACENCIES 1 1/2" = 1'-0" 1 8" POLYMERIC SAND FILLED JOINTS PAVER ON SAND SETTING BED, LEVEL WITH ADJACENT CONCRETE COMPACTED AGGREGATE, RE: CIVIL COMPACTED SUBGRADE, RE: CIVIL POLYMERIC SAND BEDADJACENT WALK POLYMERIC SAND BED SUBGRADE MULCH EDGE RESTRAINT 8 5 AMENITY PAVERS 7 OP-SS-07 AMENITY PAVERS 3/4" = 1'-0" MANUFACTURER: BELGARD MODEL: DIMENSIONS MAIN PAVER COLOR: ASPEN BAND COLOR: GRAPHITE NOTE: -THIS SPECIFICATION SHALL SERVE AS A BASIS OF DESIGN. OP-SS-08 8 BOULDER WALL 3/8" = 1'-0" COMPACTED SUBGRADE, REINFORCED BACKFILL COMPACTED 95% 6" ADJACENT TO LANDSCAPE, RE: LANDSCAPE PLAN COMPACTED SUB-GRADE 95% SPD 4" DIA. (MIN.) OUTFALL DRAINAGE SIDEWALK CRUSHED FINES BURY BOULDER 1/3 DEPTH HEIGHT VARIES, RE: GRADING PLAN DRAINAGE AGGREGATE, 12" MIN THICKNESS. WRAP WITH SOIL SEPARATOR FABRIC 6" HALF TON 2'x18"x18" SANDSTONE BOULDERS, CLEFT FACE CUT OP-SS-11 9 4" ROLL TOP METAL EDGING NTS 3" MIN OVERLAP STEEL EDGING EXISTING GRADE MULCH AREA EDGING, PIN PER MANUF. RECOMMENDATIONS NOTE: INSTALL EDGER BETWEEN CHANGES IN MULCH TYPE, BETWEEN SHRUB BEDS AND TURF OR NATIVE SEED AND BETWEEN CRUSHER FINES AND ADJACENT MATERIAL. TOP OF ROCK MULCH AND CRUSHER FINES TO BE 1 4" BELOW TOP OF EDGER, TYP. TOP OF SOD TO BE 3 4" BELOW TOP OF EDGER 4 OP-FIS-08 CRUSHER FINES AND ADJACENCIES SCALE: NTS REF: PLANS 3/8" MINUS CRUSHER FINES MATERIAL GEOTEXTILE FABIRC AS SPECIFIED. 8" COMPACTED SUBGRADE NATIVE SOIL CONCRETE 4" MIN. 10 OP-SS-12 M M M M M M M M M M M M M M MM M EM GM UGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGEUGE UG E WWWWWWWWWWWW W W G G G G G G G G G G G G UD UD UD UD UD UD UD UD UD UD UD UGE UGE WWW W WWWWWWWW W S WF PARCEL 9715418001 OWNER: BYRNE MICHAEL F, CATHERINE NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PARCEL 9715418004 OWNER: RHT LLC NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT LO W D E N S I T Y M I X E D - U S E N E I G H B O R H O O D D I S T R I C T EXISTING BUILDING (2) 2 BR UNITS) ADDITION (MAIL & BIKE STORAGE) MULTIFAMILY ADDITION ((2) 1 BR UNITS) MULTIFAMILY ADDITION ((2) 2 BR UNITS) MULTIFAMILY ADDITION (2) 2 BR UNITS PROPERTY BOUNDARY PROPERTY BOUNDARY S. S H I E L D S S T R E E T DETENTION AREA HYDROZONE - HIGH HYDROZONE - MODERATE HYDROZONE - VERY LOW DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 6 H y d r o z o n e P l a n Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 3 A M Fi l e N a m e : 6 H y d r o z o n e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER HYDROZONE PLAN FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 6 OF 17 NORTH 0 05 10 20 SCALE: 1"=10'-0" HYDROZONE AREA (SF)WATER NEEDED (GALLONS/SF)ANNUAL WATER USE (GALLONS) HIGH 3,862 18 69,516 MODERATE 7,537 14 105,518 VERY LOW 568 3 1,704 TOTAL 11,967 14.77 176,738 ANNUAL WATER USE NOT TO EXCEED 15 GAL./SF. AVERAGE OVER THE SITE WATER USE TABLE LEGEND MBMBMB FO FO FO FO FO FO OH U OH U OHU OHU OHU OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OHU OHU OHU OHU OHU OHU OHU G FO FO FO FO FO FO FO E E E E E E E E E E E E E CRITICAL ROOT ZONE, TYP. SS G E W FO X = EXISTING SANITARY SEWER = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = EXISTING TREE = EXISTING STORMWATER UTILITY = EXISTING BUILDING / STRUCTURE M = MITIGATION TREE #TYPE STEMS DBH CONDITION FORESTRY TREE MITIGATION REMOVED? FORESTRY TREE MITIGATION (IF REMOVED) REASON FOR REMOVAL / NOTES 1 ASH 1 13"FAIR 1 YES 1 TOO CLOSE TO DRIVEWAY 2 SILVER MAPLE 2 45"FAIR +5 YES 5 LOCATED IN DRIVE AISLE 3 SILVER MAPLE 2 21"FAIR +3.5 YES 3.5 LOCATED IN DRIVE AISLE 4 HONEY LOCUST 2 25"FAIR -3 YES 3 LOCATED IN DRIVE AISLE 5 CRABAPPLE 3 24"POOR +1 YES 1 LOCATED IN DRIVE AISLE 6 COTTONWOOD 1 47"POOR 3 YES 3 LOCATED IN DRIVE AISLE / BUILDING FOOTPRINT 7 SIBERIAN ELM -NA POOR 0 YES 0 LOCATED IN PARKING / POOR CONDITION 8 SIBERIAN ELM 1 10"POOR -1 YES 1 50% OF THE CRITICAL ROOT ZONE WOULD BE IMPACTED BY PARKING AND THE TREE IS IN POOR MINUS CONDITION 9 APPLE 1 15"POOR -0 YES 1 TOO CLOSE TO PARKING LOT 10 AMERICAN ELM 2 29"POOR 2 NO NA NA 11 COTTONWOOD 1 44"POOR +4 YES 4 LOCATED IN BUILDING FOOTPRINT 12 HACKBERRY 2 21"FAIR 4 YES 4 LOCATED IN BUILDING FOOTPRINT 13 PONDEROSA PINE 1 22"GOOD 4 YES 4 LOCATED IN BUILDING FOOTPRINT 14 BLUE SPRUCE 1 16.5"GOOD 4 YES 4 LOCATED IN BUILDING FOOTPRINT 15 CRAB APPLE 2 12"POOR 1 YES 1 LOCATED IN BUILDING FOOTPRINT 16 HACKBERRY -TOO SMALL -0 YES 0 TOO SMALL TO MITIGATE FOR / TOO CLOSE TO BUILDING 17 HACKBERRY -TOO SMALL -0 YES 0 TOO SMALL TO MITIGATE FOR / TOO CLOSE TO BUILDING 18 ROCK ELM ------NO LONGER ON PLANS 19 BOX ELDER -8"POOR 1 YES 1 ALONG PROPOSED FENCE 20 SIBERIAN ELM CLUSTER -CLUMP POOR 0 YES 0 TOO SMALL / POOR CONDITION 21 SIBERIAN ELM CLUSTER -CLUMP POOR 0 YES 0 TOO SMALL / POOR CONDITION TOTAL 38 37 7 OF 17 NORTH 0 05 10 20 SCALE: 1"=10'-0" TREE MITIGATION LEGEND EXISTING TREES TO SAVE IN PLACE XXX XXX TYPE MINIMUM SIZE CANOPY SHADE TREE 2.0" CALIPER AND B&B OR EQUIVALENT EVERGREEN TREE 6' HEIGHT AND B&B OR EQUIVALENT ORNAMENTAL TREE 2.0" CALIPER AND B&B OR EQUIVALENT MITIGATION SIZING CHART LEGEND #1 #17 #2 #3 #4 #5 #13 #14 #12 #15 #16 #10 #9 #8 #7 #11 #6 #19 #21 #20 PROVIDED TREE MITIGATION SUMMARY TABLE TREE MITIGATION NOTES 1.SHOULD DISCREPANCIES BE FOUND BETWEEN THE QUANTITIES LISTED IN THE PLANT TABLE AND THE QUANTITIES GRAPHICALLY SHOWN ON THE LANDSCAPE PLANS, THEN THE QUANTITIES SHOWN BY GRAPHIC SYMBOLS ON THE LANDSCAPE PLANS SHALL CONTROL NOTES: TREE MITIGATION TABLE INCLUDES FORESTRY AND ENVIRONMENTAL PLANNING MITIGATION TREES. ALL MITIGATION TREES ARE MARKED WITH AN "M" ON THE LANDSCAPE PLAN AND LANDSCAPE ENLARGEMENT PLANS. MITIGATION TREES REQUIRED MITIGATION TREES PROVIDED TREES PAID IN LIEU OF 37 17 20 *TREE MITIGATION LOCATIONS CAN BE FOUND ON THE LANDSCAPE PLAN AND LANDSCAPE PLAN ENLARGEMENTS (3). MITIGATION TREES ARE LOCATED WITH AN "M" (SEE PLAN LEGENDS FOR ICON). REMAINING MITIGATION TREES THAT CANNOT BE LOCATED ON SITE WILL BE ACCOUNTED FOR VIA CASH-IN-LIEU. TREE PROTECTION NOTES TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 7 T r e e M i t i g a t i o n P l a n Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 4 A M Fi l e N a m e : 7 T r e e M i t i g a t i o n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N RIPLEY DESIGN INC. Project Manager 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com TREE MITIGATION PLAN FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 PARCEL 9715418001 OWNER: BYRNE MICHAEL F, CATHERINE NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PARCEL 9715418004 OWNER: RHT LLC NEIGHBORHOOD CONSERVATION, BUFFER DISTRICT PA R C E L 9 7 1 5 4 1 8 0 1 0 O W N E R : M I L L E R J E R A L D B Y R O N / N O R M A R O S A R I O LO W D E N S I T Y M I X E D - U S E N E I G H B O R H O O D D I S T R I C T EXISTING BUILDING (2) 2 BR UNITS) ADDITION (MAIL & BIKE STORAGE) MULTIFAMILY ADDITION ((2) 1 BR UNITS) MULTIFAMILY ADDITION ((2) 2 BR UNITS) MULTIFAMILY ADDITION (2) 2 BR UNITS PROPERTY BOUNDARY PROPERTY BOUNDARY S. S H I E L D S S T R E E T REAR 50% OF THE LOT BUILDING IN THE REAR 50% OF THE LOT DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ev a n C a l l i s La y o u t : 7 A L L O W A B L E F L O O R A R E A E X H I B I T Pr i n t e d O n : 6/ 1 9 / 2 0 2 4 1 0 : 1 4 A M Fi l e N a m e : 7 A L L O W A B L E F L O O R A R E A E X H I B I T . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Joel Weikert 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.498.2994 f. 970.225.6657 Matthew Deault 425 Pikes Peak Ave Fort Collins, CO 80524 p. 303.931.9295 ENGINEER ARCHITECT LANDSCAPE ARCHITECT NORTHERN ENGINEERING Ryan Banning 301 N. Howes St. Ste 100 Fort Collins, CO 80521 p. 970.221.4158 JOHN DENGLER & ASSOCIATES John Dengler 5336 Highcastle Ct. Fort Collins, CO 80525 p. 970.223.1512 OWNER ALLOWABLE FLOOR AREA EXHIBIT FDP SUBMITTAL SNOW RIDGE APARTMENTS 06.19.2024FDP SUBMITTAL02 04.03.2024FDP SUBMITTAL01 FORT COLLINS, CO JW EC R23-020 8 OF 17 NORTH 0 05 10 20 SCALE: 1"=10'-0" LEGEND FLOOR AREA CALCULATION PER LAND USE CODE SECTION 4.9(D)(5), THE ALLOWABLE FLOOR AREA ON THE REAR HALF OF THE LOT SHALL NOT EXCEED THIRTY-THREE (33) PERCENT OF THE AREA OF THE REAR FIFTY (50) PERCENT OF THE LOT. REAR LOT AREA = 14,577 SF TOTAL AREA ALLOWED = 4,810 SF FLOOR AREA 1st AND 2nd FLOOR (ON REAR LOT) = 4,748 SF FLOOR AREA ON THE REAR HALF OF THE LOT: 32%