Loading...
HomeMy WebLinkAboutHEARTSIDE HILL ACCESSORY BUILDING AND CHILD CARE CENTER - FDP240007 - SUBMITTAL DOCUMENTS - ROUND 1 - Architectural Details3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE LANDSCAPE SCREENING TO SOUTH CEDAR FENCE ENCLOSURE 8' - 0"8' - 0"21' - 3 3/4"8' - 0"21' - 3 3/4" COMMUNITY ART PIECES 26 ' - 2 " HORIZONTAL FIBER CEMENT LAP SIDING -PAINT SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE ANODIZED ALUMINUM STOREFRONT SYSTEM STEEL AWNING SHADES -PAINT 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM ANODIZED ALUMINUM STOREFRONT SYSTEM -DARK BRONZE SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA 1x10 FIBER CEMENT FASCIA -PAINT 26 ' - 2 " STEEL-FRAMED ENTRY CANOPY KNOX BOX 8" HIGH ADDRESS NUMERALS 6" 12" 6" 12" SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE ANODIZED ALUMINUM STOREFRONT SYSTEM 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM ANODIZED ALUMINUM STOREFRONT SYSTEM SYNTHETIC STONE VENEER HORIZONTAL FIBER CEMENT LAP SIDING -PAINT ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY TIMBER CORBEL -STAIN SYNTHETIC STONE VENEER SYNTHETIC STONE VENEER 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM 17 ' - 1 " DASHED AREA INDICATES PHASE 2 21' - 9 1/4"26' - 1 1/4"27' - 11 1/8"27' - 1 1/8"8' - 6 1/4"4' - 0"28' - 11 1/2" STREET FACING FACADE PER 3.5.3(E)(3) FORT COLLINS LAND USE CODE FACADE LENGTH:144' -4 3/4" LINEAR FEET OF WINDOWS:77' -2" = 53.4% (50% MIN. REQUIRED) LINEAR FEET OF AWNINGS + WINDOWS:107' -3" = 74.3% 144' - 4 3/4" 15 ' - 1 1 / 4 " TIMBER CORBEL -STAIN SYNTHETIC STONE VENEER 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM 1X10 FIBER CEMENT FASCIA -PAINT 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA HORIZONTAL FIBER CEMENT LAP SIDING -PAINT SYNTHETIC STONE VENEER -CORONADO STONE OLD WORLD LEDGE -HURON 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM 1x10 FIBER CEMENT FASCIA -PAINT ANODIZED ALUMINUM STOREFRONT SYSTEM 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA 1x10 FIBER CEMENT FASCIA -PAINT HORIZONTAL FIBER CEMENT LAP SIDING -PAINT SYNTHETIC STONE VENEER ANODIZED ALUMINUM STOREFRONT SYSTEM SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE STEEL AWNING SHADES -PAINT 26 ' - 2 " DASHED AREA INDICATES PHASE 2 KNOX BOX 8" HIGH ADDRESS NUMERALS STREET FACING FACADE PER 3.5.3(E)(3) FORT COLLINS LAND USE CODE FACADE LENGTH:118' -8 1/4" LINEAR FEET OF WINDOWS:59' -4" = 50% (50% MIN. REQUIRED) LINEAR FEET OF AWNINGS + WINDOWS:85' -0" = 71.6% 118' - 8 1/4" 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM -SW 6198 SENSIBLE HUE SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE -8" X 16" FORMAT TO MATCH SPLIT FACE CMU HORIZONTAL FIBER CEMENT LAP SIDING WITH WOOD TEXTURE AND 6" EXPOSURE -SW 9106 EL CARMELO 30-YEAR HIGH-PROFILE ARCHITECTURAL ASPHALT SHINGLES -OWENS CORNING -ESTATE GRAY ALL TRIM, FLASHING, PRE-FAB AWNINGS, ETC. -SW 7069 IRON ORE MATERIAL LEGEND NOTES • ALL MECHANICAL EQUIPMENT, ELECTRICAL GEAR, GAS METERS, AND VENT PENETRATIONS ARE TO BE SCREENED OR COLOR-MATCHED TO THE ADJACENT BUILDING FAÇADE SYNTHETIC STONE VENEER -CORONADO STONE OLD WORLD LEDGE -HURON 0 1/ 2 " 1" 2" PROJECT DATE DRAWN 123 N COLLEGE AVE, SUITE 204 FORT COLLINS, CO 80524 (970) 223-1820 www.alm2s.com PR I N T E D FI L E N A M E : © al m 2 s 2 0 2 4 NOT FOR CONSTRUCTION 3/ 8 / 2 0 2 4 2 : 5 3 : 1 0 P M 00 0 0 - P r o j e c t - S D . r v t BUILDING ELEVATIONS 2317 alm2s 03/13/2024 A101 65 0 1 B r i t t a n y S t r e e t Fo r t C o l l i n s , C o l o r a d o SCALE:1/8" = 1'-0"A101 1 SOUTH ELEVATION - PHASE 1 SCALE:1/8" = 1'-0"A101 3 WEST ELEVATION - PHASE 1 SCALE:1/8" = 1'-0"A101 2 SOUTH ELEVATION - PHASE 2 SCALE:1/8" = 1'-0"A101 4 WEST ELEVATION - PHASE 2 NO ISSUE DATE He a r t s i d e H i l l A c c e s s o r y B u i l d i n g a n d Ch i l d C a r e C e n t e r 05/01/2024 1X10 FIBER CEMENT FASCIA -PAINT SYNTHETIC STONE VENEER 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA 1X10 FIBER CEMENT FASCIA -PAINT HORIZONTAL FIBER CEMENT LAP SIDING -PAINT ANODIZED ALUMINUM STOREFRONT SYSTEM SYNTHETIC STONE VENEER PAINT ELECTRICAL GEAR TO MATCH WALL FINISH LANDSCAPE SCREENING AT SOUTH OF FENCE ENCLOSURE WOOD SCREEN WALL FOR GROUND- MOUNTED MECHANICAL EQUIPMENT 6" 12" 6" 12" 6" 12" 6" 12" 26 ' - 7 " TIMBER CORBEL -STAIN SYNTHETIC STONE VENEER 1x10 FIBER CEMENT FASCIA -PAINT 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA 1X10 FIBER CEMENT FASCIA -PAINT 5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA HORIZONTAL FIBER CEMENT LAP SIDING -PAINT 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM SYNTHETIC STONE VENEER 1x10 FIBER CEMENT FASCIA -PAINT ANODIZED ALUMINUM STOREFRONT SYSTEM ANODIZED ALUMINUM STOREFRONT SYSTEM SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE 1X10 FIBER CEMENT FASCIA -PAINT DASHED AREA INDICATES PHASE 2 6" 12" 6" 12" 6" 12" HORIZONTAL FIBER CEMENT LAP SIDING -PAINT ANODIZED ALUMINUM STOREFRONT SYSTEM 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM SYNTHETIC STONE VENEER ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY ANODIZED ALUMINUM STOREFRONT SYSTEM ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM WOOD SCREEN WALL FOR GROUND- MOUNTED MECHANICAL EQUIPMENT HORIZONTAL FIBER CEMENT LAP SIDING -PAINT ANODIZED ALUMINUM STOREFRONT SYSTEM -DARK BRONZE 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY5" PRE-FINISHED METAL GUTTER ON 1X10 FIBER CEMENT FASCIA ARCHITECTURAL ASPHALT SHINGLES -DARK BROWN/GRAY HORIZONTAL FIBER CEMENT LAP SIDING -PAINT SYNTHETIC STONE VENEER 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM SYNTHETIC STONE VENEER SYNTHETIC STONE VENEER ANODIZED ALUMINUM STOREFRONT SYSTEM DASHED AREA INDICATES PHASE 2 WOOD SCREEN WALL FOR GROUND- MOUNTED MECHANICAL EQUIPMENT 3-COAT PORTLAND CEMENT BASED STUCCO SYSTEM -SW 6198 SENSIBLE HUE SYNTHETIC STONE VENEER -CORONADO STONE URBANA SPLIT -SMOKE -8" X 16" FORMAT TO MATCH SPLIT FACE CMU HORIZONTAL FIBER CEMENT LAP SIDING WITH WOOD TEXTURE AND 6" EXPOSURE -SW 9106 EL CARMELO 30-YEAR HIGH-PROFILE ARCHITECTURAL ASPHALT SHINGLES -OWENS CORNING -ESTATE GRAY ALL TRIM, FLASHING, PRE-FAB AWNINGS, ETC. -SW 7069 IRON ORE MATERIAL LEGEND NOTES • ALL MECHANICAL EQUIPMENT, ELECTRICAL GEAR, GAS METERS, AND VENT PENETRATIONS ARE TO BE SCREENED OR COLOR-MATCHED TO THE ADJACENT BUILDING FAÇADE SYNTHETIC STONE VENEER -CORONADO STONE OLD WORLD LEDGE -HURON 0 1/ 2 " 1" 2 " PROJECT DATE DRAWN 123 N COLLEGE AVE, SUITE 204 FORT COLLINS, CO 80524 (970) 223-1820 www.alm2s.com PR I N T E D FI L E N A M E : © al m 2 s 2 0 2 4 NOT FOR CONSTRUCTION 3/ 8 / 2 0 2 4 2 : 5 3 : 3 7 P M 00 0 0 - P r o j e c t - S D . r v t BUILDING ELEVATIONS 2317 alm2s 03/13/2024 A102 65 0 1 B r i t t a n y S t r e e t Fo r t C o l l i n s , C o l o r a d o SCALE:1/8" = 1'-0"A102 1 EAST ELEVATION - PHASE 1 SCALE:1/8" = 1'-0"A102 2 EAST ELEVATION - PHASE 2 SCALE:1/8" = 1'-0"A102 3 NORTH ELEVATION - PHASE 1 SCALE:1/8" = 1'-0"A102 4 NORTH ELEVATION - PHASE 2 NO ISSUE DATE He a r t s i d e H i l l A c c e s s o r y B u i l d i n g a n d Ch i l d C a r e C e n t e r 05/01/2024 3' - 3" OPENING 2' - 10"3' - 10 5/8" EXISTING SPLIT FACE CMU TRASH ENCLOSURE TO REMAIN NEW PEDESTRIAN ACCESS OPENING 6' - 0 " 7' - 1 1 5 / 8 " 7' - 1 1 5 / 8 " 9' - 11 5/8" 3' - 2" 3' - 0" 6' - 0 " 3' - 3"2' - 10"3' - 10 5/8" 2-CUBIC YARD DUMPSTER THREE (3) 64 GALLON POLYCART RECYCLE BINS (0.38 CUBIC YARDS EACH, TOTAL RECYCLING CAPACITY = 1.14 CUBIC YARDS = 57% OF PROPOSED TRASH CAPACITY) PROPOSED NEW PEDESTRIAN ACCESS PROPOSED 1" X 1" STEEL ANGLE AROUND INSIDE OF ENCLOSURE TO PROTECT AGAINST DAMAGE FORT COLLINS LAND USE CODE -SECTION 3.2.5 (C) GENERAL STANDARDS (3) Development plans must include labeled drawings of all proposed enclosures and include all proposed dumpsters, containers, bins and other receptacles and label the capacity of each. Proposed recycling capacity must be at least fifty (50) percent of the proposed trash capacity. 64 GAL. RECYCLE 64 GAL. RECYCLE 64 GAL. RECYCLE CLEAR 2' - 9" 1/2" PLATE STEEL ANCHORED TO CMU AT BOTH SIDES OF OPENING -PAINT EXISTING SPLIT FACE CMU TRASH ENCLOSURE TO REMAIN 6' - 0 " EXISTING SPLIT FACE CMU TRASH ENCLOSURE TO REMAIN 6' - 0 " EXISTING STEEL GATES TO REMAIN -PAINT AS NEEDED EXISTING SPLIT FACE CMU TRASH ENCLOSURE TO REMAIN 0 1/ 2 " 1" 2" 5 4 3 2 1 A B C D PROJECT DATE DRAWN 123 N COLLEGE AVE., SUITE 204 FORT COLLINS, CO 80524 (970) 223-1820 www.alm2s.com PR I N T E D FI L E N A M E : © al m 2 s 2 0 2 4 NOT FOR CONSTRUCTION 3/ 1 2 / 2 0 2 4 1 1 : 3 4 : 2 7 A M 00 0 0 - P r o j e c t - S D . r v t TRASH ENCLOSURE PLANS AND ELEVATIONS 2317 DWN 03/13/2024 A103 65 0 1 B r i t t a n y S t r e e t Fo r t C o l l i n s , C o l o r a d o SCALE:1/2" = 1'-0"A103 2 SOUTH ELEVATION SCALE: N 1/2" = 1'-0" 01 - TRASH ENCLOSURE PLAN SCALE:1/2" = 1'-0"A103 3 EAST ELEVATION SCALE:1/2" = 1'-0"A103 4 NORTH ELEVATION SCALE:1/2" = 1'-0"A103 5 WEST ELEVATION NO ISSUE DATE He a r t s i d e H i l l A c c e s s o r y B u i l d i n g a n d Ch i l d C a r e C e n t e r 05/01/2024 0 1/ 2 " 1" 2 " PROJECT DATE DRAWN 123 N COLLEGE AVE, SUITE 204 FORT COLLINS, CO 80524 (970) 223-1820 www.alm2s.com PR I N T E D FI L E N A M E : © al m 2 s 2 0 2 4 NOT FOR CONSTRUCTION 3/ 8 / 2 0 2 4 2 : 5 3 : 3 7 P M 00 0 0 - P r o j e c t - S D . r v t BUILDING PERSPECTIVES 2317 JW 03/13/2024 A201 65 0 1 B r i t t a n y S t r e e t Fo r t C o l l i n s , C o l o r a d o NO ISSUE DATE VIEW FROM NORTHEAST LOOKING SOUTHWEST VIEW FROM SOUTHEAST LOOKING NORTHWEST VIEW FROM SOUTHWEST LOOKING NORTHEAST VIEW FROM WEST LOOKING EAST VIEW FROM NORTHWEST LOOKING SOUTHEAST VIEW FROM SOUTH LOOKING NORTH He a r t s i d e H i l l A c c e s s o r y B u i l d i n g a n d Ch i l d C a r e C e n t e r 05/01/2024