Loading...
HomeMy WebLinkAboutWILLOX FARM - FDP240005 - SUBMITTAL DOCUMENTS - ROUND 1 - Utility PlansNO R T H C O L L E G E A V E N U E NO R T H S H I E L D S S T R E E T WEST WILLOX LANE HICKORY STREET 16' 7' PARK TRAVEL 7' PARK 8.5' (MIN.) PKWY 30' ROADWAY 57' ROW (MIN.) (MIN) WALK 5' UTIL. ESMT. 9' 9'UTIL. ESMT. (MIN.) PKWY 8.5' WALK (MIN) 5' (MIN.) WALK 42' HALF ROW 46' ROADWAY PKWY. 6' (MIN.) 10' ESMT. UTIL. 15' CENTER 10' TRAVEL 11' TRAVEL 11' 6' 2 LANE ARTERIAL (INTERIM WEST WILLOX LANE) ±40' EOA - FLRESIDENTIAL LOCAL 30' FL - FL (MIN.) WALK 84' ROW (MIN.) 52' ROADWAY 7' WALK (MIN.) (MIN.) PKWY. 10' PKWY. 6' (MIN.) 10' UTIL. ESMT. 15' ESMT. UTIL. 15' CENTER 10' TRAVEL 11' TRAVEL 11' 3' LANE BIKE 7'3' BIKE LANE BUFFER 6' BIKE LANE BUFFER LANE BIKE 2 LANE ARTERIAL (ULTIMATE WEST WILLOX LANE) 52' FL - FL ±2 . 5 ' S H O U L D E R ROW ROW ROWEX. ROW 2% MIN. CROSS-SLOPE 1.5% - 4.0% CROSS-SLOPE 2% MIN. CROSS-SLOPE BIKE LANE SECTION LINE EXISTING 30' HALF ROW TIE TO EXISTING Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CS1 CO V E R S T E E T 1 Original Field Survery: Northern Engineering Project No. 987-012 Date: November 2019 Additional Field Survey: Northern Engineering Project No. 987-012 Date: May 2020 APRIL 2024 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH City of Fort Collins Benchmark NO. 9-07. Southeast corner of Shields ST. and Willox Lane on the South east wingwall of the bridge over an irrigation ditch. ELEV.=4999.15 NGS Benchmark V-401. In Fort Collins, at the junction of U.S. 287 and Bristlecone Drive, 59.4 meters (194.9 ft) east of the north bound lanes of the highway, 14.7 meters (48.2 ft) North of the center of the drive, and 1.1 meters (3.6 ft) north of a utility pole and powerline crossing the drive, Note--access to the datum is through a 5-inch logo cap. ELEV.=4977.81 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings Assuming the North line of the Northeast Quarter of the Northwest Quarter of Section 2, Township, 7 North, Range 69 West of the 6th P.M.,as bearing North 89°33'13" East. PROJECT BENCHMARKS: WILLOX FARM PROJECT TEAM: Kristin Turner TB Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 EPS Group, Inc. | Northern Engineering Services, Inc. Amanda Poincelot 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER SHEET INDEX A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 2, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: EPS Group, Inc. | Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR TYPICAL SECTIONS FINAL UTILITY PLANS FOR Earth Engineering Consultants, LLC Preliminary Subsurface Exploration Report Proposed Residential Development Willox Farm Larimer County, Colorado EEC Project No. 1212027 Date: May 6, 2021 SUBSURFACE EXPLORATION BY: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Stephanie Rich (970) 225-7857 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Marcus Petty (720) 275-0572 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 WASTEWATER--City of Fort Collins Utilities-----------Wes Lamarque (970) 416-2418 STORMWATER-City of Fort Collins Utilities----------- Wes Lamarque (970) 416-2418 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R APPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 3 CS3 EROSION CONTROL NOTES 4 EX1 EXISTING CONDITIONS & DEMOLITION PLAN UTILITY SHEETS 5 OU1 OVERALL UTILITY PLAN 6 - 9 U1 - U4 UTILITY PLANS 10 SS1 SANITARY LINE A PLAN & PROFILE 11 SS2 SANITARY LINE A4 PLAN & PROFILE 12 SS3 SANITARY LINE A6 PLAN & PROFILE 13 SS4 SANITARY LINE A7 PLAN & PROFILE 14 WT1 WILLOX WATER LINE PLAN & PROFILE 15-16 WT2-WT3 WATER LINE A PLAN & PROFILE 17-18 WT4-WT5 WATER LINE B PLAN & PROFILE 19 WT6 WATER LINE C PLAN & PROFILE 20 WT7 WATER LINE D PLAN & PROFILE 21 ST1 STORM DRAIN A PLAN & PROFILE 22 ST2 STORM DRAINS B & C PLAN & PROFILE 23 ST3 WILLOX STORM DRAIN PLAN & PROFILE 24 ST4 WILLOX EAST STORM DRAIN PLAN & PROFILE GRADING SHEETS 25 OG1 OVERALL GRADING PLAN 26-29 G1-G4 GRADING PLAN STREET SHEETS 30 - 31 R1 - R2 SAINT THERESE STREET PLAN & PROFILE 32 R3 SAINT GRACE STREET PLAN & PROFILE 33 R4 SAINT JOSEPH STREET PLAN & PROFILE 34 R5 SAINT JEROME STREET PLAN & PROFILE 35 R6 MOLLER STREET PLAN & PROFILE 36 R7 WEST WILLOX LANE - RIGHT FLOW LINE PLAN & PROFILE 37 - 39 R8 - R10 WEST WILLOX LANE (ULTIMATE) PLAN & PROFILE 40 SG1 WEST WILLOX LANE INTERIM STRIPING PLAN 41 SG2 WEST WILLOX LANE ULTIMATE STRIPING PLAN 42 - 43 XS1 - XS2 WEST WILLOX LANE INTERIM CROSS-SECTIONS 44 - 45 INT1 - INT2 INTERSECTION DETAILS DETAIL SHEETS 46-47 D1-D2 WATER DETAILS 48 D3 SANITARY SEWER DETAILS 49-52 D4-D7 DRAINAGE DETAILS 53-54 D8-D9 SITE DETAILS DRAINAGE SHEETS 55 - 56 EC1 - EC2 EROSION CONTROL PLANS 57 EC3 EROSION CONTROL DETAILS 58 DR1 HISTORIC DRAINAGE EXHIBIT 59-60 DR2-DR3 DEVELOPED DRAINAGE EXHIBIT PROJECT LOCATION Capri Colorado Holdings, LLC James Righeimer 4040 MacArthur Blvd. Suite 250 Newport Beach, CA 92660 GEOTECHNICAL ENGINEER Earth Engineering Consultants, LLC David A. Richer, PE 4396 Greenfield Drive Windsor, Colorado 80550 (970) 545-3908 Additional Subsurface Exploration: Earth Engineering Consultants, LLC Additional Subsurface Exploration / Geothechnical Engineering Report Proposed Willox Farm Residential Development (Larimer County Parcel #970220003) Larimer County, Colorado EEC Project No. 1212027 Date: April 13, 2022 Additional Field Survey: Majestic Surveying Project No. 2020351 Date: November 2020 Additional Field Survey: Majestic Surveying Project No. 2020351 Date: April 2022 NORTHERN COLORADO WATER ASSOCIATION Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CS2 CO N S T R U C T I O N N O T E S GE N E R A L & 2 A. GENERAL NOTES 1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19.All recommendations of the Final Drainage Report dated April 12, 2024 by Northern Engineering shall be followed and implemented. 20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark NO. 9-07. Southeast corner of Shields ST. and Willox Lane on the South east wingwall of the bridge over an irrigation ditch. ELEV.=4999.15 NGS Benchmark V-401. In Fort Collins, at the junction of U.S. 287 and Bristlecone Drive, 59.4 meters (194.9 ft) east of the north bound lanes of the highway, 14.7 meters (48.2 ft) North of the center of the drive, and 1.1 meters (3.6 ft) north of a utility pole and powerline crossing the drive, Note--access to the datum is through a 5-inch logo cap. ELEV.=4977.81 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.18' Basis of Bearings Assuming the North line of the Northeast Quarter of the Northwest Quarter of Section 2, Township, 7 North, Range 69 West of the 6th P.M., as bearing North 89°33'13" East. 41.All stationing is based on centerline of roadways unless otherwise noted. 42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48.Approved Variances are listed as follows: 1) N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16.For additional information see separate Stormwater Management Plan / Erosion Control Report for Willox Farm. B. Street Improvement Notes 1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5.All lane lines for concrete pavement should be epoxy paint. 6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10.All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12.The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13.Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2.All recommendations of the Final Drainage Report dated April 12, 2024 by Northern Engineering shall be followed and implemented. 3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. INFILL AND REDEVELOPMENT NOTE A.Despite everyone's best efforts, it is impossible to fully display subsurface information prior to excavation. This is especially true in areas of infill and redevelopment. Unknown subsurface conditions can have cost and schedule implications. Prior to finalizing contract terms, it is strongly recommended that the Owner and General Contractor have a candid discussion to formulate a strategy for dealing with such circumstances when they arise. The process and procures should be in place prior to excavation. Allowances and contingencies can address the cost implications, but additional measures are required to deal with scheduling and factors impacting sequence of work. The Architect, Engineer(s), and Construction Surveyor should be made aware of the protocol for dealing with such unknown subsurface conditions prior to starting work. SOFT GOLD PARK NOTE A.The Developer shall notify PPD staff immediately if any damage to existing infrastructure in Soft Gold Park not identified in the development construction planset occurs during construction. The developer shall be responsible to restore damaged infrastructure at their cost. PPD staff must inspect and accept all restored/re_built infrastructure prior to acceptance. ADDITIONAL NOTES A.Colorado is a "Right-to-Farm" State pursuant to C.R.S 35-3.5-101 to 35-5.5-103. Landowners, residents and visitors must be prepared to accept the activities, sights, sounds, and smells of agricultural operations as a normal and necessary aspect of living in a rural or agricultural sector. State law provide that ranching, farming, or other agricultural activities and operations shall not be considered to be nuisances so long as operated in conformance with the law and in a non-negligent manner. Therefore, all must be prepared to encounter activities, sounds, odors, lights, mud, dust, smoke, chemicals, machinery on public roads, livestock on public roads, storage and disposal of manure, and the application by spraying or otherwise of chemical fertilizers, soil amendments, herbicides, And pesticides, and one or more of which may naturally occur as a part of legal and non-negligent agricultural operations. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CS3 ER O S I O N C O N T R O L N O T E S 3 STANDARD EROSION CONTROL NOTES (CITY OF FORT COLLINS) General Erosion Control Requirements These notes are a summary for the legal requirements, that are set forth in the Fort Collins Stormwater Criteria Manual (FCSCM), and that any conflict is resolved by the more stringent requirement controlling. 1.The Property Owner, Owner’s Representative, Developer, Design Engineer, General Contractor, Sub-contractors, or similar title for the developing entity (here after referred to as the Developer) has provided these Erosion Control Materials in accordance with Erosion Control Criteria set forth in the Manual as an attempt to identify erosion, sediment, and other potential pollutant sources associated with these Construction Activities and preventing those pollutants from leaving the project site as an illicit discharge. Full City requirements and are outlined and clarified in the Manual under Chapter 4: Construction Control Measures and should be used to identify and define what is needed on a project. 2.The Developer shall make themselves thoroughly familiar with the provisions and the content of the specifications laid out in the Manual, the Development Agreement, the Erosion Control Materials compiled for this project, and the following notes as all these materials are applicable to this project. 3.The Developer shall implement and maintain Control Measures for all potential pollutants from the start of land disturbing activities until final stabilization of the construction site. 4.The City Erosion Control Inspector shall be notified at least twenty-four (24) hours prior to the desired start of any construction activities on this site to allow adequate time for on-site confirmation (initial inspection which can take up to two business days after receiving the request) that the site is in fact protected from sediment and pollutants discharges off site. Please contact erosion@fcgov.com early to schedule those Initial Erosion Control Inspections well in advance so that demolition, clearing, grubbing, tree removal, and scraping may begin without delay. Failure to receive an on-site confirmation before construction activities commence is an automatic “Notice of Violation” and can result in further enforcement actions. 5.The Developer shall proactively provide all appropriate Control Measures to prevent damage to adjacent downstream and leeward properties. This includes but is not limited to: trees, shrubs, lawns, walks, pavements, roadways, structures, creeks, wetlands, streams, rivers, and utilities that are not designed for removal, relocation, or replacement in the course of construction. 6.At all times the Developer shall be responsible to ensure adequate Control Measures are designed, selected, installed, maintain, repaired, replaced, and ultimately removed in order to prevent and control erosion suspension, sediment transportation, and pollutant discharge as a result of construction activities associated with this project. 7.All applicable Control Measures based upon the sequencing and/or phasing of the project shall be installed prior to those construction activities commencing. 8.As dynamic conditions (due to the nature, timing, sequence, and phasing of construction) in the field may warrant Control Measures in addition, or different, to what is shown on these plans, the Developer shall at all times be responsible to implement the Control Measures that are most effective with the current state and progress of construction. The Developer shall implement whatever measures are determined necessary, and/or as directed by the City Erosion Control Inspector. The Developer shall insure that all Erosion Control Plans (Maps) or SWMP documents are updated to reflect the current site conditions, with updates being initialed and dated. These site inspections and site condition updates shall be made available upon request by the City. 9.All listings, provisions, materials, procedures, activities, site work and the like articulated in this or other written site-specific documents (Including but not limited to the erosion control reports, development agreements, landscape, and drainage materials) shall meet or exceed the most restrictive language for City, County, State, and Federal regulations with regards to erosion, sediment, pollutant, and other pollution source Control Measures. The Developer shall be responsible to comply with all of these aforementioned laws and regulations. 10.The Developer shall ensure that all appropriate permits (CDPS General Permit Stormwater Discharges Associated with Construction Activity, Dewatering, Clean Water Act, Army Corps of Engineers’ 404 Wetlands Mitigation Permit, etc.) have been attained prior to the relevant activity has begun. These permits or copies shall be made available upon request by the City. 11.The Developer shall furnish all conveniences and assistances to aid the Erosion Control Inspectors of materials, workmanship, records, and self-inspections, etc. of the Control Measures involved in the construction activities. 12.The Developer shall request clarification of all apparent site construction issues that may arise due to inconsistencies in construction plans for the site or site conditions around the selected Control Measures by contacting the Erosion Control Inspector. The Erosion Control Inspector will not be responsible for any explanations, interpretations, or supplementary data provided by others. 13.All Control Measures shall be installed in accordance with the Manual. 14.The City reserves the right to require additional Control Measures as site conditions warrant, to the extent authorized by relevant legal authority. 15.As with any construction standards, occasions may arise where the minimum erosion control standards are either inappropriate or cannot be justified. In these cases, a variance to these standards may be applied for pursuant to the terms, conditions, and procedures of the Manual. 16.Inspection. The contractor shall inspect site pollutant sources and implement Control Measures at a minimum of once every two weeks during construction and within 24 hours following a precipitation event. Documentation of each inspection shall be recorded and retained by the contractor. 17.All temporary Control Measures shall be cleaned, repaired, or reconstructed as necessary in order to assure continual performance of their intended function. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any drainage way. 18.Any Control Measure may be substituted for another standard Control Measure so long as that Control Measure is equal to, or of greater protection than the original Control Measure that was to be used in that location. (ex. silt fence, for wattles, or for compact berms) Wattle alone on commercial construction sites have shown to be an ineffective substitute for silt fence or compact berms unless it is accompanied by a construction fence to prevent vehicle traffic. 19.Any implementation or replacement of existing Control Measures for a non-standard control, or alternative Control Measure, shall require the review and acceptance by the City erosion control staff before the measure will be allowed to be used on this project. These Control Measures’ details shall be submitted, reviewed and accepted to be in accordance with the Erosion Control Criteria based upon the functionality and effectiveness in accordance with sound engineering and hydrological practices Land disturbance, Stockpiles, and Storage of Soils 20.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. Off road staging areas or stockpiles must be preapproved by the City. Disturbances beyond these limits will be restored to original condition. 21.Pre-disturbance vegetation shall be identified, protected, and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area required for immediate construction operations, and for the shortest practical period of time. This should include sequencing and phasing construction activities in a way so that the soil is not exposed for long periods of time by schedule or limit grading to small areas. This should also include when practical advancing the schedule on stabilization activities such that landscaping takes place shortly if not immediately after grading has occurred. Vegetation efforts shall start as soon as possible to return the site to a stabilized condition. Sensitive areas should avoid clearing and grading activities as much possible. 22.All exposed soils or disturbed areas are considered a potential pollutant and shall have Control Measures implemented on the site to prevent materials from leaving the site. 23.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition at all times by equipment tracking, scarifying or disking the surface on a contour with a 2 to 4 inch minimum variation in soil surface until mulch, vegetation, and/or other permanent erosion control is installed. 24.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport through the use of surface roughening, watering, and down gradient perimeter controls. All soil stockpiles shall be protected from sediment transport by wind in accordance with Municipal Code §12-150. All stockpiles shall be flattened to meet grade or removed from site as soon as practical, and no later than the completion of construction activities or abandonment of the project. All off-site stockpile storage locations in City limits shall have a stockpile permit from the City Engineering Department prior to using the area to store material. If frequent access from hardscape to the stockpile is needed a structural tracking Control Measure shall be implemented. 25.All required Control Measures shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc.). All of the required erosion Control Measures must be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 26.All inlets, curb-cuts, culverts, and other storm sewer infrastructure which could be potentially impacted by construction activities shall be protected with Control Measures. Material accumulated from this Control Measure shall be promptly removed and in cases where the protection has failed, the pipes shall be thoroughly cleaned out. 27.All streams, stream corridors, buffers, woodlands, wetlands, or other sensitive areas shall be protected from impact by any construction activity through the use of Control Measures. 28.All exposed dirt shall have perimeter control. Any perimeter controls that drain off or has the ability to be tracked onto the nearby hardscape shall have some form of effective sediment control as the, or as part of the, perimeter control. 29.All exposed slopes should be protected. All exposed steep slopes (Steeper than 3:1 H:V) shall be protected from erosion and sediment transport through use of Control Measures. 30.No soils shall remain exposed by land disturbing activity for more than thirty (30) days after activity has ceased before required temporary seeding or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. This is not just limited to projects that are abandoned; this includes any project that is temporarily halted and no immediate activity is to resume within the next thirty (30) days, unless otherwise approved by the City Erosion Control Inspector. During a season when seeding does not produce vegetative cover, another temporary erosion control shall be implemented with or until temporary seeding or permanent erosion control can be performed. 31.All individual lots shall have effective sediment controls located on the street side and any down gradient side. Typically most lots drain to the front yet on those cases where houses are along a pond or drainage swale have the lot drain in a different direction than the street, those individual lots will need protection on that down gradient side to prevent sediment from leaving the lot. See the Individual Lot Details for further clarification. Vehicle Tracking 32.At all points where vehicles exit or leave the exposed dirt area on to a hardscape or semi hardscape (concrete, asphalt, road base, etc.) shall have installed at least one structural tracking Control Measure to prevent vehicle tracking. All areas not protected by an adequate perimeter control shall be considered a point where vehicles exit the site. Access points should be limited to as few entrances as possible (All perimeter areas shall be protected from tracking activities). 33.In all areas that the structural tracking Control Measures fail to prevent vehicle tracking, collection and proper disposal of that material is required. All inlets located near access points and affected by tracking activities shall be prevented from the introduction of sediment into the drainage system. 34.City Municipal Code §20-62, among other things, prohibits the tracking, dropping, or depositing of soils or any other material onto city streets by or from any source. City Municipal Code, §26-498, among other things, prohibits the discharge of pollutants on public or private property if there is a significant potential for migration of such pollutant. Therefore, all tracked or deposited materials (intentional or inadvertent) are not permitted to remain on the street or gutter and shall be removed and legally disposed of by the Developer in a timely and immediate manner. Dirt ramps installed in the curb-lines are not exempt to these sections of code and shall not be permitted in the street right of way (public or private). 35.If repeated deposit of material occurs on a site, additional structural tracking controls may be required of the Developer by the City Erosion Control Inspector. Loading and Unloading Operations 36.The Developer shall apply Control Measure to limit traffic (site worker or public) impacts and proactively locate material delivered to the site in close proximity to the work area or immediately incorporated in the construction to limit operational impacts to disturbed areas, vehicle tracking, and sediment deposition that could impact water quality. Outdoor Storage or Construction Site Materials, Building Materials, Fertilizers, and Chemicals 37.Any materials of a non-polluting nature (steel, rock, brick, lumber, etc.) shall be inspected for any residue coming off the material during routine inspection and will generally be located where practical at least fifty (50) feet from any permanent or interim drainage ways. 38.Any high environmental impact pollutant materials that have a high likelihood to result in discharge when in contact with stormwater (lubricants, fuels, paints, solvents, detergents, fertilizers, chemical sprays, bags of cement mix, etc.) should not be kept on site where practical. When not practical, they should be stored inside (vehicle, trailer, connex, building, etc.) and out of contact with stormwater or stormwater runoff. Where not available, they shall be stored outside in a raised (high spots or on pallets), covered (plastic or tarped), and sealed (leak proof container) in secondary containment location. The secondary containment or other Control Measure shall be adequately sized, located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as part of the routine inspections. Vehicle and equipment maintenance and fueling 39.Parking, refueling, and maintenance of vehicles and equipment should be limited in one area of the site to minimize possible spills and fuel storage areas. This area shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as part of the routine inspections. All areas shall keep spill kits and supplies close. Significant Dust or Particulate generating Process 40.The property must be actively preventing the emission of fugitive dust at all times during construction and vegetation activities. All land disturbing activities that result in fugitive dust shall be in accordance with Municipal Code §12-150 to reduce the impacts to adjacent properties and community health. All required practices shall be implemented and additional ones shall be followed. These practices include watering the sites and discontinuing construction activities until the wind subsides as determined by any City Inspectors. Concrete truck / equipment washing, including the concrete truck chute and associated fixtures and equipment 41.All concrete and equipment washing shall use structural Control Measures appropriate to the volume of wash and frequency of use. These Control Measures shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as part of the routine inspections. These areas shall be clearly identified and protected from any wash from leaving the Control Measure. If frequent access from hardscape to the Control Measure is to occur, a structural tracking Control Measure shall be implemented. These Control Measures shall be frequently cleaned out. 42.The Developer is responsible for ensuring washing activity is taking place at the appropriate Control Measure and site workers are not washing or dumping wash water on to the dirt or other uncontrolled locations. Dedicated Asphalt and concrete batch plants 43.Dedicated asphalt and concrete batch plants are not acceptable on construction sites within the City of Fort Collins without an expressed written request and plan to reduce pollutants associated with that type of activity and approval by the City of Fort Collins specifically the Erosion Control Inspector. The Developer shall inform the erosion control inspection staff of any dedicated asphalt, or concrete batch plants that is to be used on site. Concrete Saw Cutting Materials 44.Saw cutting material shall be in accordance with Municipal Code §12-150 for air emissions and all water applications to the saw cutting shall prevent material from leaving the immediate site and collected. These cutting locations, once dried, shall be swept and scraped of all material and shall have proper and legal disposal. Waste Materials Storage and Sanitary Facilities 45.Trash, debris, material salvage, and/or recycling areas shall be, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be monitored as part of the routine inspections. These facilities should be located out of the wind and covered as able. Where not able to cover, locating said areas on the side of other structures to reduce exposure to winds, and follow maximum loading guidelines as marked on the container. The Developer is required to practice good housekeeping to keep the construction site free of litter, construction debris, and leaking containers. 46.Sanitary facilities shall be prevented from tipping through the use of anchoring to the ground or lashing to a stabilized structure. These facilities shall also be located as far as practical from an inlet, curb cut, drainage swale or other drainage conveyances to prevent material transport from leaving the local area. This consists of the facility being located, where practical, at least fifty (50) feet from any permanent or interim drainage ways. Other Site Operations and Potential Spill Areas 47.Spills: For those minor spills that; are less than the State’s reportable quantity for spills, stay within the permitted area, and in no way threaten any stormwater conveyance, notify the City of Fort Collins Utilities by email at erosion@fcgov.com or phone (970) 817-4770. For any significant, major, or hazardous spills, notify the City of Fort Collins Utilities by phone only after Emergency Response (911) has been notified and is on route, County Health Department (LCDHE) has been notified through Larimer County Sheriff Dispatch (970) 416-1985, and the State Spill Hotline Incident Reporting have been contacted 1-877-518-5608. Written documentation shall be provided to the City within 5 days of the event. All spills shall be cleaned up immediately. 48.Selection of “plastic welded” erosion control blankets shall not be used in areas that wildlife, such as snakes, are likely to be located as these have proven to cause entrapment issues. Final stabilization and project completion 49.Any stormwater facilities used as a temporary Control Measure will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the Owner, Homeowners Association (HOA), or other party responsible for long term maintenance of those facility. 50.All final stabilization specifications shall be done in accordance with the Manual, Chapter 4: Construction Control Measures. 51.All disturbed areas designed to be vegetated shall be amended, seeded & mulched, or landscaped as specified in the landscape plans and per City of Fort Collins standards within 14 working days of final grading. 52.Soil in all vegetated (landscaped or seeded) areas, including parkways and medians shall comply with all requirements set forth in Sections 12-130 through 12-132 of the City Municipal Code, as well as Section 3.8.21 for the City Land Use Code. 53.All seeding shall refer to landscaping plans or the Erosion Control Plans for species mixture and application rates and depths requirements. 54.All seed shall be drilled where practical to a depth based upon the seed type. Broadcast seeding shall be applied at double the rate as prescribed for drill seeding and shall be lightly hand raked after application. Hydroseeding may be substituted for drill seeding on slopes steeper than 3(H):1(V) or on other areas not practical to drill seed and crimp and mulch. All hydroseeding must be conducted as two separate processes of seeding and tackification. 55.All seeded areas must be mulched within twenty-four (24) after planting. All mulch shall be mechanically crimped and or adequately applied tackifier. The use of crimped mulch or tackifier may require multiple re-applications if not properly installed or have weathered or degraded before vegetation has been established. Areas of embankments having slopes greater than or equal to 3H:1V shall be stabilized with an erosion mat or approved equal to ensure seed will be able to germinate on the steep slopes. During a season when seeding doesnot produce vegetative cover, another temporary erosion control shall be implemented along with, or until, temporary seeding or permanent erosion control can be performed. 56.The Developer shall warranty and maintain all vegetative measures for two growing seasons after installation or until seventy percent (70%) vegetative cover has been established, whichever is longer and meets all the Criteria outlined in the Fort Collins Stormwater Criteria Manual Chapter 4: Construction Control Measures. 57.The Developer shall maintain, monitor, repair, and replace any and all applicable Control Measures until final stabilization has been obtained. All Control Measures must remain until such time as all upstream contributing pollutant sources have been vegetated or removed from the site. When any Control Measure is removed, the Developer shall be responsible for the cleanup and removal of all sediment and debris from that Control Measure. At the point at which the site has been deemed stabilized and verified by City Erosion Control Inspector, all temporary Control Measures can then be fully removed. All measures shall be removed within 30 days after final stabilization is achieved. 58.The responsible party shall maintain and keep current all payments or related forms of security for the Erosion Control Escrow until 1) stabilization has been reached and 2) all Control Measures and/or BMPs have sediment materials collected and the Control Measure removed from the site. At that time the site will be considered completed and any remaining Erosion Control Escrow shall be returned to the appropriate parties. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R W WWW W W W T W S S W T T ELECS S MS W W T S MM W M H Y D FO FO XXX G OHU FO W W W W W W W W W W FO X G FO FO G G G X X X X X X X FO FO OHU OHU OHU OHU W W FO FO X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO G G G G G G FO FO FO FO FO FO E E E E E W W W XXXXXXXXXXXXX X X OHU OHU OHU OHU OHU O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU X X X X X X X X X X X X W W W W W W W W W ACKELSON CONNIE A.KAFKA, AMY PITT, JEAN GBP LLC. WEST WILLOX LANE SOFT GOLD DOG PARK JE N S E N G O R D O N L . PEREZ DANIEL A. PEREZ DANIEL A. / / / / / / / / / / / / / / / / ////////////// EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED (ENCROACHES ON PROPERTY. SEE PLAT FOR NOTES) EXISTING 20' PRIVATE DRAINAGE EASEMENT TO BE CONVERTED TO PUBLIC EASEMENT EXISTING 10' UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 30' NORTHERN COLORADO WATER ASSOCIATION (NCWA) EASEMENT REMOVE APPROXIMATELY 656' OF EXISTING BARBWIRE FENCE EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 60' ROW 100' UNION PACIFIC RAILROAD ROW EXISTING OUT BUILDING PROPERTY BOUNDARY EXISTING GREEN HOUSES EXISTING GAS LINE REMOVE AND RELOCATE EXISTING OVERHEAD UTILITIES EXISTING FIBER OPTIC CABLE EXISTING BARBWIRE FENCE (PROTECT IN PLACE) EXISTING BARBWIRE FENCE EXISTING BARBWIRE FENCE EXISTING BARBWIRE FENCE TO BE REMOVED EXISTING 6' WOOD \PRIVACY FENCE EXISTING TREE (TYP.) EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING DENSE SHRUBS & TREES EXISTING TREE (TYP.) EXISTING STEEL PANELS w/ WOOD POSTS ENCROACHES ON PROPERTY. DO NOT REMOVE EXISTING UNDERGROUND ELECTRICAL REMOVE AND RELOCATE EXISTING R.R. CROSSING SIGN EXISTING UTILITY POLE (TYP.) EXISTING MAILBOX (TYP.) EXISTING 12" RCP CULVERT REMOVE EXISTING TREE/BUSH REMOVE & REPLACE EXISTING BURIED PIPE UNION PACIFIC RAILROAD EXISTING SANITARY MANHOLE CENTERLINE OF TWO TRACK DIRT ROAD CENTERLINE OF TWO TRACK DIRT ROAD EXISTING 12" PVC WATER LINE (FORT COLLINS) EXISTING GAS METER (TYP.) EXISTING FIRE HYDRANT REMOVE EXISTING TREE (TYP.) REMOVE AND RELOCATE EXISTING TELEPHONE PEDESTAL REMOVE AND RELOCATE EXISTING SIGN EXISTING NoCO WATER LINE REMOVE EXISTING UTILITY POLE REMOVE ± 665 LF EXISTING STRIPING REMOVE & REPLACE ±9,900 SF OF ASPHALT EXISTING WATER METER (TYP.) EXISTING NORTHERN COLORADO WATER ASSOCIATION WATER MAIN EXISTING OVER HEAD LINE TO TO BE REPLACED UNDER GROUND EXISTING GATE EXISTING NORTHERN COLORADO WATER ASSOCIATION WATER MAIN EXISTING GATE REMOVE APPROXIMATELY 160' OF EXISTING DOG PARK FENCE LIMITS OF SAWCUT & TRENCH FOR WATER LINE BORNING LIMITS OF SAWCUT & TRENCH FOR WATER LINE BORINGLIMITS OF SAWCUT EXISTING ELECTRICAL TRANSFORMER EXISTING GAS METER (TYP.) W W W WTESTSTA CONTROLIRR CONTROLIRR CONTROLIRR CONTROL IRR CONTROLIRR CONTROL IRR CONTROLIRR CONTROLIRRCONTROLIRR W W E E E X X X X X X X X X X CSW H2O C S CS VAULT ELEC HYD CONTROLIRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROLIRR ELEC C.O. S OHU OHU E E E E E E X X X X X X X X X X X X X X X X X X X X X W W Xh2o / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / XX SOFT GOLD BICYCLE COURSE SOFT GOLD PARK NO SURVEY DATA IN THIS AREA NO SURVEY DATA IN THIS AREA SOFT GOLD BASKETBALL COURTS EXISTING PLAYGROUND SOFT GOLD BASEBALL DIAMOND CITY OF FORT COLLINS HI C K O R Y V I L L A G E S U B D I V I S I O N CI T Y O F F O R T C O L L I N S // / / / / 40' ROW EXISTING 20' UTILITY EASEMENT EXISTING 50' TEMP CONSTRUCTION EASEMENT EXISTING COFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) HANSON WILLIAM A/ MERIAM P WETLAND BOUNDARY SHRUB & TREE BOUNDARY SOFT GOLD PARK BICYCLE COURSE TRACK RULES SHRUB & TREE BOUNDARY (APPROXIMATE) CENTERLINE OF TWO TRACK DIRT ROAD EXISTING NATURAL AREA SIGN RESTROOMS EXISTING 6' CONCRETE TRAIL TO BE REMOVED & REPLACED EXISTING GAZEBO EXISTING 8' CRUSHER FINES PATH TO BE REMOVED & REPLACED EXISTING TREE (TYP.) EXISTING DOG PARK FENCE EXISTING 6' CONCRETE TRAIL REMOVE & REPLACE EXISTING PEDESTRIAN RAMP EXISTING PEDESTRIAN RAMP EXISTING 8" PVC STORM LINE EXISTING UNDERGROUND ELECTRIC LINES EXISTING FENCE EXISTING 36" WATER MAIN (ANHEUSER-BUSCH) EXISTING 8" WATER LINE RELOCATE EXISTING FIRE HYDRANT REMOVE ±110' OF EXISTING 8" WATER LINE & 8" GATE VALVE EXISTING TREES (TYP.) PROPOSED SAW CUT PROPOSED SAW CUT REMOVE ±3260 SF OF EXISTING CONCRETE TRAIL REMOVE & REPLACE ±895 SF OF EXISTING ASPHALT REMOVE EXISTING CRUSHER FINES TRAIL REMOVE AND RELOCATE EXISTING IRRIGATION BOXES REMOVE AND RELOCATE EXISTING IRRIGATION BOXES EXISTING WATER & IRRIGATION METERS PROPOSED SAW CUT EXISTING 6' CONCRETE TRAIL TO BE REMOVED & REPLACED PROPOSED SAW CUT TEST STATION EXISTING COFC CATHODIC PROTECTION TEST STATION ON CONCRETE PAD EXISTING WATER SERVICE SOFT GOLD PARKING LOT CAPE SEAL ±15,000 SF APPROXIMATE LOCATION EXISTING 24" WATER (ELCO) REMOVE & REPLACE ±180 SF OF SIDEWALK REMOVE & REPLACE ±30 LF OF 18" VERTICAL CURB & GUTTER EXISTING STORM DRAIN REMOVE & REPLACE ±1,640 SF OF EXISTING ASPHALT Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 EX1 DE M O L I T I O N P L A N EX I S T I N G C O N D I T I O N S & 4 NORTH ( IN FEET ) 1 inch = ft. Feet08080 80 160 240 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.THERE SHALL BE NO EQUIPMENT, MATERIALS, OR ITEMS STORED ON A FORT COLLINS PARKS TRAIL OR WITHIN THE TRAIL EASEMENT. IF THERE IS A NEED TO CLOSE A SECTION OF THE TRAIL FOR ANY REASON, A TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AND APPROVED THROUGH TRAFFIC CONTROL. THE PARKS DEPARTMENT WILL SIGN OFF ON IT ONCE SUBMITTED. PLEASE KEEP THE CLOSURES TO THE SHORTEST AMOUNT OF TIME DEPENDING ON WORK SCHEDULING AND FLOW. PARKS DEPARTMENT PLANNING STAFF CAN HELP WITH ANY QUESTIONS YOU MAY HAVE REGARDING THESE STANDARDS. PLEASE CONTACT JILL WUERTZ (jwuertz@fcgov.com), 9704162062, OR PARKS PLANNING TECHNICIAN, AARON WAGNER (aawagner@fcgov.com) 9706820344, 413 S. BRYAN AVE, FORT COLLINS, CO 80521 REGARDING THE PARKS’ DEPARTMENT’S INTEREST. 7.THERE SHALL BE NO ENCROACHMENTS INTO THE TRAIL EASEMENT DURING THE CONSTRUCTION PROCESS. IF IT IS DETERMINED THAT AN ENCROACHMENT IS REQUIRED, FOR ANY REASON, PLEASE CONTACT ONE OF THE ABOVE PARKS REPRESENTATIVES. EXISTING OVERHEAD UTILITY OHE Original Field Survery: Northern Engineering Project No. 987-012 Date: November 2019 (Additional May 2020) S W EXISTING METAL FENCE POST EXISTING WOOD FENCE POST Earth Engineering Consultants, LLC Preliminary Subsurface Exploration Report Proposed Residential Development Willox Farm Larimer County, Colorado EEC Project No. 1212027 Date: May 6, 2021 Additional Subsurface Exploration: Earth Engineering Consultants, LLC Additional Subsurface Exploration / Geothechnical Engineering Report Proposed Willox Farm Residential Development (Larimer County Parcel #970220003) Larimer County, Colorado EEC Project No. 1212027 Date: April 13, 2022 EXISTING CRUSHER FINES TRAIL (TO BE REMOVED) EXISTING CONCRETE TRAIL (TO BE REMOVED) EXISTING ASPHALT (TO BE REMOVED) Additional Field Survey: Majestic Surveying Project No. 2020351 Date: April 2022 LIMITS OF TRENCHING WITHIN EXISTING ROAD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R LIMITS OF SAW CUT W WWW W W W T W S S W T ELECS S T MS W W WM T S MM W M H YD FO FO XXX G G OHU OHU FO FO W W W W W W W W W W W FO X G FO FO G G G X X X X X X X FO FO OHU OHU OHU OHU W W FO FO X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO G G G G G G FO FO FO FO FO FO E E E E E W W W X X O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU X X X X X X X X W W W W W W W W W W / / / / / / / / ACKELSON CONNIE A. 603 W WILLOX LANE,KAFKA, AMY PITT, JEAN GBP LLC EXISTING 10' UTILITY EASEMENT 12" SS 12" SS 12" SS 12" SS 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W T UG E UG E UGE UGE UGE U G E U G E VAU L TELE C 12" SS 12 " S S 1 2 " S S 1 2 " S S UD U DUD UGE UGE UGE UGE UGE UGE UGE UGE IR PEREZ DANIEL A. 400 HICKORY STREET 149 PEREZ DANIEL A. 400 HICKORY STREET 149 EXISTING 6' CITY OF FORT COLLINS EASEMENT LOT 3 LOT 8 LOT 10 LOT 9 LOT 7 LOT 6 LOT 1 LOT 2 LOT 4 LOT 5 LOT 14 LOT 13 LOT 12 LOT 6 LOT 8 LOT 7 LOT 5 LOT 11 LOT 10 LOT 9 LOT 1 LOT 2 LOT 3 LOT 4 LOT 9 LOT 8 LOT 3 LOT 2 LOT 4 LOT 5 LOT 6 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 7 LOT 1 LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 10 LOT 1LOT 2LOT 3 LOT 4LOT 5LOT 6 LOT 7 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 TRACT B DE TRACT A DE,UE,AE TRACT D TRACT C DE BLOCK 3 BLOCK 6 BLOCK 2 BLOCK 5 BLOCK 4 BLOCK 1 PROPOSED FIRE HYDRANT PROPOSED 2' SIDEWALK CHASE CONNECT TO EXISTING 12" DIP WATER LINE EXISTING NCWA WATERLINE TO BE PROTECTED IN PLACE EXISTING FH PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED POND OUTLET STRUCTURE 18" STEEL CASING TO BE BORED UNDER UNION PACIFIC ROW REMOVABLE BOLLARDS (TYP.) PROPOSED FOREBAY (TYP.) PROPOSED FOREBAY FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) PROPOSED UNDERGROUND ELECTRIC RAIN GARDEN B BIOMEDIA AREA RAIN GARDEN A BIOMEDIA AREA EXISTING 20' PRIVATE DRAINAGE EASEMENT TO BE CONVERTED TO PUBLIC EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 30' NCWA EASEMENT 100' UNION PACIFIC RAILROAD ROW 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE PROPOSED DETENTION POND SANITARY LINE A4 SS2 SEE SHEET SANITARY LINE A SEE SHEET SS1 SANITARY LINE A7 SEE SHEET SS4 SANITARY LINE A6 SEE SHEET SS3 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT WILLOX STORM DRAIN SEE SHEET ST3 STORM DRAIN A SEE SHEET ST1 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CHASE PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN w/ 6" CURBS PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN SA I N T T H E R E S E S T R E E T SA I N T J E R O M E S T R E E T SAINT JOSEPH STREET MOLLER STREET SAINT GRACE STREET WEST WILLOX LANE PROPOSED 4' SIDEWALK CULVERT 18' UTILITY EASEMENT RG B UNDERDRAIN SEE SHEET U2 PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN WILLOX WATER LINE SEE SHEET WT1 WATER LINE B SEE SHEET WT4-WT5 WATER LINE B SEE SHEET WT4-WT5 WATER LINE C SEE SHEET WT6 WATER LINE A SEE SHEET WT2-WT3 WATER LINE D SEE SHEET WT7 WATER LINE C SEE SHEET WT6 PROPOSED 4' CONCRETE PAN w/ 7" CURBS RG A UNDERDRAIN SEE SHEET U2 WILLOX EAST STORM DRAIN SEE SHEET ST4 EMERGENCY OVERFLOW WEIR PROPOSED 2" IRRIGATION METER W W W WTESTSTA CONTROLIRR CONTROL IRR CONTROL IRR CONTROL IRR W W E E E X X X X X X X X X CSW H2O CS C S VAULT ELEC CONTROL IRR CONTROL IRR CONTROLIRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR ELEC C.O. B M S OHU OHU E E E E E E X X X X X X X X X X X X X X X X X X X X X X X W W Xh2o XX X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / UGE UG E UG E U G E U G E U G E U G E UG E UG E U G E U G E UG E UG E UG E U G E U G E UG E UG E UG E PE R E Z D A N I E L A . 40 0 H I C K O R Y S T R E E T 1 4 9 HANSON WILLIAM A/ MERIAM P EXISTING RESTROOMS EXISTING GAZEBO CONNECT TO EXISTING 8" PVC WATER LINE REPLACE ± 140 LF OF FENCE ALONG EASEMENT LINE EXISTING 36" WATER LINE (ANHEUSER- BUSCH) TO BE PROTECTED IN PLACE TEST STATION COFC CATHODIC PROTECTION TEST STATION ON CONCRETE PAD PROPOSED FIRE HYDRANT REMOVABLE BOLLARDS APPROXIMATE LOCATION EXISTING 24" WATER LINE (ELCO) TO BE PROTECTED IN PLACE PROPOSED UNDERGROUND ELECTRIC (TYP.) 40' ROW EXISTING 20' UTILITY EASEMENT EXISTING 50' TEMP CONSTRUCTION EASEMENT COFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) BICYCLE COURSE DOG PARK SOFT GOLD PARK BASKETBALL COURTS EXISTING PLAYGROUND BASEBALL DIAMOND PARKING LOT WOOD DUCK POND HICKORY STREET CULVERT SEE SHEET U4 4 - EXISTING 8" STORM PIPES EXISTING 30" STORM DRAIN WATER LINE A SEE SHEET WT2-WT3 WATER LINE A SEE SHEET WT2-WT3 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 OU1 OV E R A L L U T I L I T Y P L A N 5 NORTH ( IN FEET ) 1 inch = ft. Feet08080 80 160 240 NOTES: EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL HOMES SHALL FEATURE 13D SPRINKLER SYSTEMS. PROPOSED UNDER GROUND ELECTRIC UGE UGE EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING GAS METER EXISTING WATER METER EXISTING MAIL BOX M 19' UTILITY EASEMENT MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET U1 U2 U3 U4 W WWW W S S W T ELEC S S M W W T S MM W M H YD FO FO FO XXXX G G OHU OHU FO FO W W W W W W W W W W W W W W W W W W W WFOFOFO X X G G G FO FO FO F O W G G G G G G G X X X X X X X X X X X X X X FO FO FO FO FO OHU OHU OHU OHU O H U OHU OHU OHU OHU W W W FO FO FO FO X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FO FO FO FO FO G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FOFO G E E E E E E E E E E E W W W W W W OHU O H U O H U O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU WWWWWWWWW W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W T 12" SS 12" SS 12" S S 12" SS 12 " S S 12 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W WW W W WW WW W W W W W W W SS S UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE IR / / / / / / / / / / / / / / / / / / / / / / / / SA I N T T H E R E S E S T R E E T S A I N T J E R O M E S T R E E T MOLLER STREET SAINT JOSEPH STREET ACKELSON CONNIE A. KAFKA, AMY PEREZ DANIEL A. LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 7 LOT 1 LOT 7 LOT 5 BLOCK 4 TRACT A DE,UE,AE TRACT A DE,UE,AE TRACT B DE 8" PVC WATER EXISTING 30' NCWA UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT LOT 6 LOT 1 LOT 2 LOT 3 LOT 9 LOT 8 LOT 3 LOT 2 LOT 4 LOT 5 LOT 6 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 4 TRACT C DE LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 BLOCK 1 BLOCK 5 BLOCK 5 BLOCK 2 TRACT C DE EXISTING 6' CITY OF FORT COLLINS UTILITY EASEMENT 57' ROW 57' ROW 30' - 30' - 30' - 100' UNION PACIFIC RAILROAD ROW 72' ROW EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT CONNECT TO EXISTING 12" DIP WATERLINE REMOVE STUBPROPOSED 10' CONCRETE TRAIL EXISTING FIRE HYDRANT EXISTING NCWA WATERLINE EXISTING NCWA WATERLINE ± 114 LF PROPOSED 24" STAINLESS STEEL CASING TO BE BORED UNDER UNION PACIFIC ROW EXISTING EDGE OF ASPHALT PROPOSED 10' CONCRETE TRAIL FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' S I D E W A L K UTILITY EASEMENT (WIDTH VARIES) UTILITY EASEMENTUTILITY EASEMENT WEST WILLOX LANE 6 ' U T I L I T Y E A S E M E N T 6 ' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 18' UTILITY & DRAINAGE EASEMENT 18' UTILITY EASEMENT PROPOSED FIRE HYDRANT EXISTING SSMH PROPOSED 2' CONCRETE PAN PROPOSED 4' CONCRETE PAN w/ 6" CURBS SANITARY LINE A4 SEE SHEET WT2-WT3 SANITARY LINE A SEE SHEET SS1 SANITARY LINE A7 SEE SHEET SS4 WILLOX STORM DRAIN SEE SHEET ST3 WILLOX WATER LINE SEE SHEET WT1 WATER LINE B SEE SHEET WT4-WT5 WATER LINE B SEE SHEET WT4-WT5 WATER LINE D SEE SHEET WT7 PROPOSED 4' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) WILLOX EAST STORM DRAIN SEE SHEET ST3 WILLOX EAST STORM DRAIN SEE SHEET ST3 PROPOSED 4' CONCRETE PAN w/ 7" CURBS PROPOSED 4' SIDEWALK CULVERT 1 1 1 1 1 1 1 PROPOSED 2" IRRIGATION METER Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 U1 UT I L I T Y P L A N 6 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet0#### ## ##### NOTES: EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL HOMES SHALL FEATURE 13D SPRINKLER SYSTEMS. PROPOSED UNDER GROUND ELECTRIC UGE UGE EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING GAS METER EXISTING WATER METER EXISTING MAIL BOX M 19' UTILITY EASEMENT MATCH LINE - SEE SHEET U2 U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R W W T W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX X X X X X X X X X X 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS UG E UG E UG E UG E UG E UGE UGE UGE UGE UGE UGE UGE UG E U G E UGE U G E UGE U G E VAU L TELE C UD UD UD U D U D UD S S S S S S S S S S S S S SS SSSS S S S S S S S S W W W W W W W WWW W W W W W W W W W W W W W W S S SS W W W W W W UD UD X X SA I N T T H E R E S E S T R E E T SA I N T J E R O M E S T R E E T MOLLER STREET MOLLER STREET SAINT GRACE STREET PITT, JEAN GBP LLC PEREZ DANIEL A. LOT 3 LOT 3LOT 4 LOT 5LOT 6 LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 7 LOT 8 LOT 10 LOT 9 LOT 7 LOT 6 LOT 1 LOT 2 LOT 4 LOT 5 LOT 8 LOT 7 LOT 11 LOT 10 LOT 9 LOT 10 LOT 1 LOT 2 BLOCK 3 BLOCK 6 BLOCK 2 TRACT D TRACT A DE,UE,AE 8" PVC WATER LOT 14 LOT 13 LOT 12 EXISTING 20' DRAINAGE EASEMENT 57' ROW 57' ROW 30' - 30' - 57' ROW 30' - 57' ROW 30' - 57' ROW 30' - 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' DRAINAGE EASEMENT (BY SEPARATE DOCUMENT) PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED 10' CONCRETE TRAIL PROPOSED 10' CONCRETE TRAIL 50' NATURAL FEATURE BUFFER FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE ( BY OTHERS) EXISTING 10' UTILITY EASEMENT 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 15' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T DOG PARK 6' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T PROPOSED OUTLET STRUCTURE PROPOSED FOREBAY PROPOSED FOREBAY PROPOSED RAIN GARDEN A BIOMEDIA AREA PROPOSED RAIN GARDEN B BIOMEDIA AREA PROPOSED FOREBAY PROPOSED INLET PROPOSED INLET PROPOSED UNDERGROUND ELECTRIC PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN w/ 6" CURBS SANITARY LINE A6 SEE SHEET SS3 STORM DRAIN A SEE SHEET ST1 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 WATER LINE C SEE SHEET WT6 WATER LINE A SEE SHEET WT2-WT3 WATER LINE C SEE SHEET WT6 WATER LINE B SEE SHEET WT4-WT5 PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) PROPOSED 2' SIDEWALK CHASE 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN RG B BEND w CO & ELBOW 1-2 INV. IN=4982.40 (N) INV. OUT=4983.40 (S) FG=4985.76 RG B CO 1-3-1 INV. OUT=4982.56 (W) FG=4985.75 RG B CO 1-4 INV. OUT=4982.59 (S) FG=4985.73 RG B PIPE END 1 FG=4983.96 RG B TEE 1-3 INV.=4982.48 FG=4982.85 55.98 LF 4" PERF. HDPE @ 0.20% 39.87 LF 4" PERF. HDPE @ 0.20% 16.80 LF 6" HDPE @ 0.20% 41.28 LF 4" PERF. HDPE @ 0.20% RG A BEND w CO 1 INV.=4983.37 FG=4986.44 RG A CO 1-6 INV. OUT=4982.75 (SE) FG=4986.13 RG A BEND w CO & ELBOW 1-2 INV. IN=4982.52 (NE) INV. OUT=4983.44 (S) FG=4985.89 OUTLET C2 INV. IN=4982.98 (E) INV. OUT=4982.98 (SW) FG=4985.45 RG A 1-5 INV.=4982.70 FG=4983.07 RG A 1-4 INV.=4982.65 FG=4983.02 RG A 1-3 INV.=4982.56 FG=4982.92 388.24 LF 6" HDPE @ 0.10% 76.73 LF 6" HDPE @ 0.10% 33.40 L F 4" PER F . H D P E @ 0.10 % 91.19 LF 4" PERF. HDPE @ 0.10% 54.96 LF 4" PERF. HDPE @ 0.10% 43.50 LF 4" PERF. HDPE @ 0.10% SMALL PIPE HEADWALL (SEE DETAIL) PROPOSED 2' CONCRETE PAN EMERGENCY OVERFLOW WEIR 1 1 1 1 1 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 U2 UT I L I T Y P L A N 7 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet0#### ## ##### NOTES: EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL HOMES SHALL FEATURE 13D SPRINKLER SYSTEMS. PROPOSED UNDER GROUND ELECTRIC UGE UGE EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING GAS METER EXISTING WATER METER EXISTING MAIL BOX M 19' UTILITY EASEMENT MATCH LINE - SEE SHEET U3 MATCH LINE - SEE SHEET U1 U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X UG E UG E U G E U G E U G E U G E U G E UG E UG E UG E UG E UG E U G E U G E U G E U G E U G E UG E UG E UG E UG E UG E UG E UG E X X JENSEN GORDON L. CITY OF FORT COLLINS PEREZ DANIEL A. 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) PROPOSED 10' CONCRETE TRAIL SOFT GOLD PARK CITY OF FORT COLLINS IRRIGATION POND PROPOSED 12' CONCRETE TRAIL PROPOSED 12' CONCRETE TRAIL PROPOSED CONCRETE TRAIL (WIDTH VARIES) WATER LINE A SEE SHEET WT2-WT3 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 U3 UT I L I T Y P L A N 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 NOTES: EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL HOMES SHALL FEATURE 13D SPRINKLER SYSTEMS. PROPOSED UNDER GROUND ELECTRIC UGE UGE EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING GAS METER EXISTING WATER METER EXISTING MAIL BOX M 19' UTILITY EASEMENT MATCH LINE - SEE SHEET U4 MATCH LINE - SEE SHEET U2 U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R W W W W W W W WTESTSTA CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR W W W W EE E E E E E E X X X C SW H2O CS CS VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR ELEC C.O. S OHU OHU OHU OHU E E E E E E E E E E E E X X X X X X X X X X X X X E X X X X X X W W W W XXh2o XXXX UGEUGE UG E UG E UG E UG E U G E U G E U G E U G E U G E U G E U G E U G E U G E U G E U G E UG E UG E UG E UG E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CITY OF FORT COLLINS CITY OF FORT COLLINS PEREZ DANIEL A. HANSON WILLIAM A/ MERIAM P 40' ROW EXISTING 20' UTILITY EASEMENT EXISTING 50' TEMP CONSTRUCTION EASEMENT COFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) CONNECT TO EXISTING 8" PVC WATER MAIN PROPOSED FIRE HYDRANT EXISTING 36" ANHEUSER-BUSH WATER MAIN EXISTING 8" PVC WATER MAIN EXISTING RESTROOMS EXISTING 30" STORM DRAIN EXISTING TEST STATION COFC CATHODIC PROTECTION TEST STATION ON CONCRETE PAD EXISTING 12" SANITARY SEWER EXISTING WATER SERVICE SOFT GOLD PARK HICKORY STREET BASKETBALL COURTS EXISTING PLAYGROUND BASEBALL DIAMOND PARKING LOT CONNECT EXISTING METER TO NEW SERVICE LINE APPROXIMATE LOCATION EXISTING 24" ELCO WATER MAIN PROPOSED 12' CONCRETE TRAIL WOOD DUCK POND WATER LINE A SEE SHEET WT2-WT3 FES F1 FG=4980.67 FES F FG=4980.52 23.05 LF 12" RCP @ 0.68% EXISTING 4-8" PVC STORM DRAIN Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 U4 UT I L I T Y P L A N B. Ruch KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 NOTES: EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL HOMES SHALL FEATURE 13D SPRINKLER SYSTEMS. PROPOSED UNDER GROUND ELECTRIC UGE UGE EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT / / / / / / / / EXISTING GAS METER EXISTING WATER METER EXISTING MAIL BOX M 19' UTILITY EASEMENT MATCH LINE - SEE SHEET U3 U1 U2 U3 U4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12 " S S 12 " S S 1 2 " S S 1 2 " S S 1 2 " S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S W W W W W W W W W W W W W W W W W W W W WW W W SS WW WW W W W W W W W SS S IR W WWW W W S X X X X X X XXXX X X X X X X X X X X X X X X X X X X X X E E E E E W 57' ROW 30' - BLOCK 6 LOT 9 TRACT A DE,UE,AE S A I N T T H E R E S E S T R E E T S A I N T J E R O M E S T R E E T EXMH A STA 10+00.00 N: 139339.55 E: 192323.69 20.00 LF 12" PVC @ 0.22% SSMH A1 STA 10+20.00 N: 139332.69 E: 192304.90 54.53 LF 12" PVC @ 0.22% SSMH A2 STA 10+74.53 N: 139299.90 E: 192261.34 134.36 LF 12" PVC @ 0.22% SSMH A3 STA 12+08.89 N: 139301.65 E: 192126.99 83.56 LF 12" PVC @ 0.22% SSMH A4 STA 12+92.45 N: 139281.31 E: 192045.94 196.73 LF 12" PVC @ 0.22% SSMH A5 STA 14+89.17 N: 139089.52 E: 192089.73 136.63 LF 12" PVC @ 0.22% SSMH A6 STA 16+25.80 N: 138952.89 E: 192088.81 311.26 LF 12" PVC @ 0.22% SSMH A7 STA 19+37.06 N: 138954.99 E: 191777.55 180.24 LF 12" PVC @ 0.22% SSMH A8 STA 21+17.30 N: 138956.20 E: 191597.32 30' - 30' - 57' ROW 30' - 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K UTILITY EASEMENT 15' UTILITY EASEMENT UTILITY EASEMENT 15' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 6 ' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6 ' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 9 ' U T I L I T Y E A S E M E N T SANITARY LINE A7 SEE SHEET SS4 STORM DRAIN A SEE SHEET ST1 WATER LINE B SEE SHEET WT4-WT5 WATER LINE D SEE SHEET WT7 WATER LINE B SEE SHEET WT4-WT5 TRACT B DE LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 8 LOT 3 LOT 2 LOT 4 LOT 5 LOT 6 LOT 7 LOT 1 LOT 13 LOT 6 LOT 1 LOT 2 LOT 3 LOT 8 LOT 7 LOT 5 LOT 4 LOT 9 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 TRACT C DE BLOCK 2 BLOCK 5 BLOCK 6BLOCK 3 BLOCK 4 BLOCK 5 LOT 6 LOT 5 30' SANITARY SEWER EASEMENT 1 0 ' C O N C R E T E T R A I L 10 ' C O N C R E T E T R A I L CONNECT TO EXISTING SANITARY MANHOLE CORE DRILL & RESHAPE BASE WATER SERVICE (TYP.) ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 SANITARY LINE A4 SEE SHEET SS2 SANITARY LINE A6 SEE SHEET SS3 FUTURE IRRIGATION (CITY OF FORT COLLINS) (BY OTHERS) MOLLER STREET WATER LINE C SEE SHEET WT6 WILLOX EAST STORM DRAIN SEE SHEET ST4 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+0022+00 180.24 LF 12" PVC @ 0.22% SS M H A 8 ST A 2 1 + 1 7 . 3 0 RI M 4 9 8 8 . 1 ± IN V . O U T 4 9 8 5 . 3 2 ( E ) SS M H A 7 ST A 1 9 + 3 7 . 0 6 RI M 4 9 9 2 . 4 ± IN V . I N 4 9 8 4 . 9 2 ( W ) IN V . I N 4 9 8 5 . 2 6 ( N ) IN V . O U T 4 9 8 4 . 8 2 ( E ) 311.26 LF 12" PVC @ 0.22% SS M H A 6 ST A 1 6 + 2 5 . 8 0 RI M 4 9 9 1 . 7 ± IN V . I N 4 9 8 4 . 1 5 ( W ) IN V . I N 4 9 8 4 . 4 9 ( S ) IN V . O U T 4 9 8 3 . 9 5 ( N ) SS M H A 5 ST A 1 4 + 8 9 . 1 7 RI M 4 9 9 0 . 9 ± IN V . I N 4 9 8 3 . 6 6 ( S ) IN V . O U T 4 9 8 3 . 4 6 ( N ) 136.63 LF 12" PVC @ 0.22% 196.73 LF 12" PVC @ 0.22% SS M H A 4 ST A 1 2 + 9 2 . 4 5 RI M 4 9 8 9 . 8 ± IN V . I N 4 9 8 3 . 0 3 ( S ) IN V . I N 4 9 8 3 . 3 7 ( N W ) IN V . O U T 4 9 8 2 . 8 3 ( E ) 83.56 LF 12" PVC @ 0.22% SS M H A 3 ST A 1 2 + 0 8 . 8 9 RI M 4 9 8 9 . 6 ± IN V . I N 4 9 8 2 . 6 5 ( W ) IN V . O U T 4 9 8 2 . 4 5 ( E ) 134.36 LF 12" PVC @ 0.22% SS M H A 2 ST A 1 0 + 7 4 . 5 3 RI M 4 9 8 8 . 3 ± IN V . I N 4 9 8 2 . 1 6 ( W ) IN V . O U T 4 9 8 1 . 9 6 ( N E ) 54.53 LF 12" PVC @ 0.22% SS M H A 1 ST A 1 0 + 2 0 . 0 0 RI M 4 9 8 8 . 5 ± IN V . I N 4 9 8 1 . 8 4 ( S W ) IN V . O U T 4 9 8 1 . 6 4 ( E ) 20.00 LF 12" PVC @ 0.22% EX M H A ST A 1 0 + 0 0 . 0 0 RI M 4 9 8 8 . 4 ± IN V . I N 4 9 8 1 . 6 0 ( W ) IN V . I N 4 9 8 1 . 4 0 ( N ) IN V . O U T 4 9 8 1 . 4 0 ( S ) 8" PVC WATER STA.=16+35.80 TOP=4987.37 8" PVC WATER STA.=19+47.06 TOP=4983.42 18" MIN. CONNECT TO EXISTING SANITARY MANHOLE CORE DRILL & RESHAPE BASE 30 0 . 0 0 L F 1 5 " H D P E @ 0 . 5 0 % 15" HDPE IRRIGATION FUTURE (BY OTHERS) STA.=21+07.30 INV.=4982.23 30" RCP STORM STA.=20+83.20 INV.=4986.77 PROPOSED GROUND EXISTING GROUND18" MIN. 2.5" ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 12" HDPE STORM STA.=11+28.65 INV.=4987.12 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SS1 PL A N & P R O F I L E SA N I T A R Y L I N E A 10 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SANITARY LINE A PROFILE SCALE: SANITARY LINE A EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE CITY OF FORT COLLINS, LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 12" SS 12" SS 12" SS 1 2 " S S S S S S S S S S S W W W W W W W WW WW W W SS S IR W WWW S X X X X X X X X X X X X X E E E E E E E E E W W W W O H U 30' -TRACT A DE,UE,AE SA I N T T H E R E S E S T R E E T SSMH A4 STA 10+00.00 N: 139281.31 E: 192045.94 6' CITY OF FORT COLLINS UTILITY EASEMENT 57' ROW 30' - 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT SANITARY LINE A7 SEE SHEET SS4 WATER LINE B SEE SHEET WT4-WT5 WATER LINE D SEE SHEET WT7 TRACT B DE LOT 6 LOT 5 LOT 8 LOT 6 LOT 7 LOT 1 LOT 9 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 TRACT C DE BLOCK 2BLOCK 5 BLOCK 5 30' SANITARY SEWER EASEMENT 10 ' C O N C R E T E T R A I L WATER SERVICE (TYP.) SANITARY LINE A SEE SHEET SS1 BLOCK 1 SSMH A4-4 STA 12+72.23 N: 139410.57 E: 191832.22 75.23 LF 8" PVC @ 1.00% SSMH A4-3 STA 11+97.01 N: 139409.60 E: 191907.44 SSMH A4-2 STA 11+13.62 N: 139374.45 E: 191983.05 83.38 LF 8" PVC @ 0.50% 70.99 LF 8" PVC @ 0.50% SSMH A4-1 STA 10+42.63 N: 139320.53 E: 192029.23 42.63 LF 8" PVC @ 0.50% BLOCK 4 EXISTING SANITARY SEWER MANHOLE WILLOX EAST STORM DRAIN SEE SHEET ST4 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0013+50 PROPOSED GROUND EXISTING GROUND 75.23 LF 8" PVC @ 1.00% SS M H A 4 - 4 ST A 1 2 + 7 2 . 2 3 RI M 4 9 9 1 . 1 ± IN V . O U T 4 9 8 5 . 7 0 ( E ) 83.38 LF 8" PVC @ 0.50% SS M H A 4 - 3 ST A 1 1 + 9 7 . 0 1 RI M 4 9 9 0 . 6 ± IN V . I N 4 9 8 4 . 9 5 ( W ) IN V . O U T 4 9 8 4 . 7 5 ( S E ) SS M H A 4 - 2 ST A 1 1 + 1 3 . 6 2 RI M 4 9 9 0 . 2 ± IN V . I N 4 9 8 4 . 3 3 ( N W ) IN V . O U T 4 9 8 4 . 1 3 ( S E ) 70.99 LF 8" PVC @ 0.50% 42.63 LF 8" PVC @ 0.50% SS M H A 4 - 1 ST A 1 0 + 4 2 . 6 3 RI M 4 9 8 9 . 6 ± IN V . I N 4 9 8 3 . 7 8 ( N W ) IN V . O U T 4 9 8 3 . 5 8 ( S E ) SS M H A 4 ST A 1 0 + 0 0 . 0 0 RI M 4 9 8 9 . 8 ± IN V . I N 4 9 8 3 . 0 3 ( S ) IN V . I N 4 9 8 3 . 3 7 ( N W ) IN V . O U T 4 9 8 2 . 8 3 ( E ) Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SS2 PL A N & P R O F I L E SA N I T A R Y L I N E A 4 11 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SANITARY LINE A4 PROFILE SCALE: SANITARY LINE A4 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE CITY OF FORT COLLINS, LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS UG E U G E UGE U G E U G E VAU L TELE C 12 " S S UD U D S S S S S S S S S S S S S SS SSSS S S S S S S S S W W W W W W W W WWW W W W W W W W W W W W WW W W W S S SS W W WW WW UD W W T W X X X X X X X X X X X X X X X X X X X X X X X X X 30' -5' SIDEWALK 6' UTILITY EASEMENT BLOCK 6 BLOCK 3 BLOCK 2 LOT 3 LOT 8 LOT 10 LOT 9 LOT 7 LOT 1 LOT 2 LOT 4 LOT 11 LOT 10 LOT 9 LOT 1 LOT 2LOT 3LOT 4LOT 5LOT 6 LOT 7 LOT 14 LOT 13 LOT 12 TRACT D SAINT GRACE STREET SSMH A6 STA 10+00.00 N: 138952.89 E: 192088.81 EXISTING 20' DRAINAGE EASEMENT 57' ROW 57' ROW 30' - 30' - 57' ROW 30' - 57' ROW 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 15' UTILITY EASEMENT 15' UTILITY EASEMENT UTILITY EASEMENT 15' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T STORM DRAIN A SEE SHEET ST1 STORM DRAIN B SEE SHEET WATER LINE C SEE SHEET WT6 WATER LINE A SEE SHEET WT2-WT3 WATER LINE C SEE SHEET WT6 LOT 10 LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 8 LOT 7 BLOCK 6 BLOCK 3 LOT 6 LOT 5 WATER SERVICE (TYP.) ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 SANITARY LINE A SEE SHEET SS1 TRACT A DE,UE,AE SANITARY LINE A SEE SHEET SS1 290.64 LF 8" PVC @ 0.40% SSMH A6-1 STA 12+90.64 N: 138662.26 E: 192086.86 37.28 LF 8" PVC @ 0.40% SSMH A6-2 STA 13+27.92 N: 138636.08 E: 192060.32 284.90 LF 8" PVC @ 0.40% SSMH A6-3 STA 16+12.82 N: 138637.99 E: 191775.42 SSMH A6-4 STA 17+96.32 N: 138821.49 E: 191776.66 183.50 LF 8" PVC @ 0.40% ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 BLOCK 2 FUTURE IRRIGATION (CITY OF FORT COLLINS) (BY OTHERS) RAIN GARDEN B BIOMEDIA AREA RG B UNDERDRAIN SEE SHEET U2 WATER LINE B SEE SHEET WT4-WT5 RAIN GARDEN A BIOMEDIA AREA RG A UNDERDRAIN SEE SHEET U2 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0018+50 PROPOSED GROUND EXISTING GROUND SS M H A 6 ST A 1 0 + 0 0 . 0 0 RI M 4 9 9 1 . 7 ± IN V . I N 4 9 8 4 . 1 5 ( W ) IN V . I N 4 9 8 4 . 4 9 ( S ) IN V . O U T 4 9 8 3 . 9 5 ( N ) 290.64 LF 8" PVC @ 0.40% SS M H A 6 - 1 ST A 1 2 + 9 0 . 6 4 RI M 4 9 9 0 . 4 ± IN V . I N 4 9 8 5 . 8 4 ( S W ) IN V . O U T 4 9 8 5 . 6 4 ( N ) 37.28 LF 8" PVC @ 0.40% SS M H A 6 - 2 ST A 1 3 + 2 7 . 9 2 RI M 4 9 9 0 . 2 ± IN V . I N 4 9 8 6 . 1 8 ( W ) IN V . O U T 4 9 8 5 . 9 8 ( N E ) 284.90 LF 8" PVC @ 0.40% SS M H A 6 - 3 ST A 1 6 + 1 2 . 8 2 RI M 4 9 9 2 . 0 ± IN V . I N 4 9 8 7 . 5 1 ( N ) IN V . O U T 4 9 8 7 . 3 1 ( E ) 183.50 LF 8" PVC @ 0.40% SS M H A 6 - 4 ST A 1 7 + 9 6 . 3 2 RI M 4 9 9 3 . 2 ± IN V . O U T 4 9 8 8 . 2 4 ( S ) 18" MIN. ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 8" PVC WATER STA.=16+43.32 TOP=4986.11 8" PVC WATER STA.=13+03.37 TOP=4984.37 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 18" MIN. Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SS3 PL A N & P R O F I L E SA N I T A R Y L I N E A 6 12 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SANITARY LINE A6 PROFILE SCALE: SANITARY LINE A6 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE CITY OF FORT COLLINS, LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 12 " S S 12 " S S 12 " S S 12 " S S S S S S S S S S S S S S S S S W W W W W W W WW WW W S S S S WW W W W W W W W W S S S IR X X X X X X X X X X X X X LOT 3LOT 4 SAINT THERESE STREET SSMH A7 STA 10+00.00 N: 138954.99 E: 191777.55 57 ' RO W 30 ' -30 ' - 57' ROW FO R F U T U R E C I T Y O F F O R T C O L L I N S 5' S I D E W A L K 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T UT I L I T Y E A S E M E N T UT I L I T Y E A S E M E N T 15 ' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 6' UTILITY EASEMENT 6' UTILITY EASEMENT SANITARY LINE A SEE SHEET SS1 STORM DRAIN A SEE SHEET ST1 WATER LINE B SEE SHEET WT4-WT5 WATER LINE C SEE SHEET WT6 WATER LINE D SEE SHEET WT7 TRACT B DE LOT 6 LOT 1LOT 2LOT 3LOT 4LOT 5 LOT 8 LOT 3 LOT 2LOT 4LOT 5LOT 6LOT 7 LOT 1 LOT 12 LOT 11LOT 13 BLOCK 6 BLOCK 3BLOCK 4 BLOCK 5 LOT 5 WATER SERVICE (TYP.) SANITARY LINE A4 SEE SHEET SS2 57 ' RO W SSMH A7-2 STA 13+49.16 N: 139304.02 E: 191770.19 252.38 LF 8" PVC @ 0.60% SSMH A7-1 STA 10+96.78 N: 139051.77 E: 191778.20 96.78 LF 8" PVC @ 0.50% FUTURE IRRIGATION (CITY OF FORT COLLINS) (BY OTHERS) PROPOSED 2" IRRIGATION METER 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+00 PROPOSED GROUND EXISTING GROUND SS M H A 7 ST A 1 0 + 0 0 . 0 0 RI M 4 9 9 2 . 4 ± IN V . I N 4 9 8 4 . 9 2 ( W ) IN V . I N 4 9 8 5 . 2 6 ( N ) IN V . O U T 4 9 8 4 . 8 2 ( E ) 96.78 LF 8" PVC @ 0.50% 252.38 LF 8" PVC @ 0.60% SS M H A 7 - 1 ST A 1 0 + 9 6 . 7 8 RI M 4 9 9 3 . 1 ± IN V . I N 4 9 8 5 . 9 4 ( N ) IN V . O U T 4 9 8 5 . 7 4 ( S ) SS M H A 7 - 2 ST A 1 3 + 4 9 . 1 6 RI M 4 9 9 2 . 2 ± IN V . O U T 4 9 8 7 . 4 6 ( S ) Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SS4 PL A N & P R O F I L E SA N I T A R Y L I N E A 7 13 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SANITARY LINE A7 PROFILE SCALE: SANITARY LINE A7 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE CITY OF FORT COLLINS, LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S W T ELEC S S T MS W W WM W W T S MM W M H YD MM FO FO FO FO XXXX X XX G G G G G OHU OHU OHU OHU FO FO FO FO FO W W X W W W W W W W W W W W W W W W W WFOFO X G G FO FO F O W G G G G G G G G X X X X X X X X X X X X X X X X X X FO FO FO FO OHU OHU OHU OHU OHU O H U OHU OHU OHU OHU OHU OHU W W W W W FO FO FO FO FO FO X X X X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FO FO FOGGGGGGGGGGG FO FO FO FO FO FO FO FO FO FOFO G E E E E W W W W W OHU O H U O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU WWWWWWWWWW W W W W W W W W W / / / / / / / / / / / / / / / / TRACT A DE,UE,AE KAFKA, AMY EXISTING 30' NCWA UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS UTILITY EASEMENT 57' ROW 30' - 100' UNION PACIFIC RAILROAD ROW 72' ROW EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE PROPOSED FIRE HYDRANT PROPOSED 10' CONCRETE TRAIL EXISTING FIRE HYDRANT EXISTING NCWA WATERLINE ±114' LF 24" STEEL CASING TO BE BORED UNDER UNION PACIFIC ROW EXISTING EDGE OF ASPHALT FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) 5' SIDEWALK 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T WEST WILLOX LANE 6' UTILITY EASEMENT 18' UTILITY EASEMENT 18' UTILITY EASEMENT PROPOSED 2' CONCRETE PAN ACKELSON CONNIE A. TRACT B DE BLOCK 1 LOT 3 LOT 1 LOT 2 LOT 5 LOT 4 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W T S S S S S W W W W W 30.81 LF 12" PVC N66°26'52"W 145.90 LF 12" PVC N89°09'59"W 471.89 LF 12" PVC N89°09'45"W 162.50 LF 12" PVC N89°09'48"W 8.00 LF 12" PVC N89°09'59"W STA.=10+00.00 REMOVE STUB & CONNECT TO EXISTING WATER LINE 22.5° BEND w/MJR N:139625.22 E:192410.03 STA.=10+30.81 22.5° BEND w/MRJ 1 - 12" GV (W) N:139637.53 E:192381.79 STA.=11+76.71 1 - 12" GV N:139639.65 E:192235.90 STA.=16+48.61 12"X8" TEE w/MJR 1 - 12" GV (E) 1 - 8" GV (S) N:139646.55 E:191764.06 STA.=18+11.11 12"X6" TEE w/MJR 1 - 12" GV (W) 1 - 6" GV (S) 1 - FH ASSEMBLY (S) N:139648.92 E:191601.58 STA.=18+19.11 12" STUB RESTRAINED TO TEE (E) N:139649.04 E:191593.58 SA I N T T H E R E S E S T R E E T PROPOSED 4' SIDEWALK CULVERT WILLOX STORM DRAIN SEE SHEET ST3 WATER LINE B SEE SHEET WT4-WT5 WILLOX EAST STORM DRAIN SEE SHEET ST3 ±41' EOP-FL FIRE HYDRANT N:139622.68 E:191601.24 EXISTING NCWA WATERLINE 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0018+60 12" PVC12" PVC ST A . 1 0 + 0 0 . 0 RE M O V E S T U B & C O N N E C T T O E X . W A T E R L I N E 22 . 5 ° B E N D T. O . P . = 4 9 8 7 . 6 5 ST A . 1 7 + 7 9 . 8 45 ° B E N D T. O . P . = 4 9 8 7 . 5 2 ST A . 1 8 + 1 9 . 1 12 " S T U B RE S T R A I N E D T O T E E ( E ) T. O . P . = 4 9 8 7 . 6 1 ST A . 1 7 + 8 3 . 3 45 ° B E N D T. O . P . = 4 9 8 4 . 0 3 ST A . 1 7 + 9 0 . 8 45 ° B E N D T. O . P . = 4 9 8 4 . 0 3 ST A . 1 7 + 9 4 . 4 45 ° B E N D T. O . P . = 4 9 8 7 . 6 1 ST A . 1 0 + 3 0 . 8 1 22 . 5 ° B E N D 1 - 1 2 " G V ( W ) T. O . P . = 4 9 8 7 . 6 4 ST A . 1 1 + 7 6 . 7 1 1 - 1 2 " G V T. O . P . = 4 9 8 7 . 6 2 ST A . 1 6 + 4 8 . 6 1 12 " X 8 " T E E 1 - 1 2 " G V ( E ) 1 - 8 " G V ( S ) T. O . P . = 4 9 8 7 . 5 5 ST A . 1 8 + 1 1 . 1 1 12 " X 6 " T E E 1 - 1 2 " G V ( W ) 1 - 6 " G V ( S ) 1 - F H A S S E M B L Y ( S ) T. O . P . = 4 9 8 7 . 6 1 PROPOSED GROUND EXISTING GROUND 113.30 LF 24" STEEL CASING @ 0.00% STA.=11+68.49 INV. = 4986.126 STA.=10+55.19 INV. = 4986.126 49 9 3 . 1 0 49 9 3 . 0 6 49 9 2 . 9 5 49 9 2 . 8 4 49 9 2 . 7 5 49 9 2 . 6 5 49 9 2 . 5 9 49 9 2 . 5 6 49 9 2 . 5 6 49 9 2 . 5 4 49 9 2 . 5 6 49 9 2 . 5 4 49 9 2 . 5 3 49 9 2 . 5 4 49 9 2 . 6 1 49 9 2 . 6 6 49 9 2 . 7 3 49 9 2 . 8 4 49 9 2 . 9 9 49 9 3 . 1 0 TOP OF PIPE PROPOSED GROUND FUTURE 15" HDPE IRRIGATION (BY OTHERS) STA.=17+87.11 INV.=4985.70 18" MIN. Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT1 PL A N & P R O F I L E WI L L O X W A T E R L I N E 14 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: WILLOX WATER LINE KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV NORTH WT1 W W W W W W W TES T STA CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR WWWEE E EE E X X X X X X X X X X C SW H2O C S C S VAU L T ELEC CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR CON T R O L IRR ELECC.O . B M S OH U OH U OH U E E E E E E E E E E X X X X X X X X X X X X E X X X X X W W W X X h2o X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / UGE UGE UGE UGE UGE UG E UGE UGE UGEUGEUGE UGE UGE U G E U G E U G E U G E U G E U G E UG E UGE U G E U G E U G E U G E U G E U G E UG E UGE U G E 56.03 LF 8" PVC N89°33'35"W 66.44 LF 8" PVC N67°03'35"W 133.5 0 L F 8 " P V C N67°0 3 ' 3 5 " W 67.94 LF 8" PVC N22°03'35"W 140.15 LF 8" PVC N39°32'35"W 40.48 LF 8" PVC N02°07'18"W 50.59 LF 8" PVC N24°54'24"E 91.54 LF 8"PVCR=300.00' 195.94 LF 8"PVC R=300.00' 161.41LF 8" P V C R=300.00' 3 0 2.9 3 LF 8" PVC R =300.00' STA.=10+00.00 CONNECT TO EXISTING WATERLINE 1 - 8" GV w/MJR N:137033.04 E:192458.90 STA.=10+56.03 22.5° BEND w/MRJ N:137033.47 E:192402.87 STA.=11+22.47 8"X6" SWIVEL TEE 1 - 6" GV (NE) 1 - 8" GV (NW) 1 - FH ASSEMBLY (NE) N:137059.36 E:192341.69 STA.=12+55.96 45° BEND w/MJR N:137111.40 E:192218.75 STA.=13+23.90 BEGIN HORIZ. DEFLECTION STA.=14+15.45 END HORIZ. DEFLECTION STA.=15+55.59 BEGIN HORIZ. DEFLECTION STA.=17+51.53 END HORIZ. DEFLECTION STA.=17+92.01 BEGIN HORIZ. DEFLECTION STA.=19+53.43 BEGIN HORIZ. DEFLECTION STA.=19+53.43 END HORIZ. DEFLECTION SOFT GOLD PARK HIC K O R Y S T R E E T BASKETBALL COURTS EXISTING PLAYGROUND BASEBALL DIAMOND PARKING LOT EXISTING 36" ANHEUSER-BUSH WATER MAIN EXISTING 8" PVC WATER MAIN EXISTING RESTROOMS EXISTING 30" STORM DRAIN EXISTING TEST STATION COFC CATHODIC PROTECTION TEST STATION ON CONCRETE PAD EXISTING 12" SANITARY SEWER EXISTING WATER SERVICE CONNECT EXISTING METER TO NEW SERVICE LINE APPROXIMATE LOCATION EXISTING 24" ELCO WATER MAIN PROPOSED 12' CONCRETE TRAIL EXISTING 4-8" STORM DRAINCOFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) CITY OF FORT COLLINS PEREZ DANIEL A. HANSON WILLIAM A/ MERIAM P CULVERT SEE SHEET U4 40' U T I L I T Y EA S E M E N T (BY S E P A R A T E DO C U M E N T ) 4955 4960 4965 4970 4975 4980 4985 4990 4995 4955 4960 4965 4970 4975 4980 4985 4990 4995 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+0021+50 30" RCP STORM STA.=10+71.47 INV.=4975.22 36" WATER STA.=10+96.38 TOP=4974.83 8" P V C 8" PVC 8" PVC8" PVC 8" PVC 8" PVC 8" PV C ST A . 1 0 + 0 0 . 0 CO N N E C T T O E X I S I T N G W A T E R L I N E 1 - 8 " G V T. O . P . = 4 9 7 4 . 3 9 ST A . 1 7 + 6 1 . 0 0. 5 ° D E F L E C T I O N T. O . P . = 4 9 7 5 . 3 6 ST A . 1 0 + 6 1 . 4 45 ° B E N D T. O . P . = 4 9 7 4 . 3 9 ST A . 1 0 + 6 6 . 5 45 ° B E N D T. O . P . = 4 9 7 0 . 2 4 ST A . 1 1 + 1 1 . 9 45 ° B E N D T. O . P . = 4 9 7 5 . 8 0 ST A . 1 1 + 0 6 . 4 45 ° B E N D T. O . P . = 4 9 7 0 . 2 4 ST A . 1 1 + 2 2 . 5 1. 2 ° D E F L E C T I O N T. O . P . = 4 9 7 5 . 8 0 ST A . 1 0 + 5 6 . 0 3 22 . 5 ° B E N D T. O . P . = 4 9 7 4 . 3 9 ST A . 1 1 + 2 2 . 4 7 8" X 6 " S W I V E L T E E 1 - 6 " G V ( N E ) 1 - 8 " G V ( N W ) 1 - F H A S S E M B L Y ( N E ) T. O . P . = 4 9 7 5 . 8 0 ST A . 1 2 + 5 5 . 9 6 45 ° B E N D T. O . P . = 4 9 7 3 . 1 5 ST A . 1 3 + 2 3 . 9 0 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 2 . 9 8 ST A . 1 5 + 5 5 . 5 9 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 5 . 7 4 ST A . 1 7 + 9 2 . 0 1 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 5 . 0 4 ST A . 1 4 + 1 5 . 4 5 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 5 . 1 9 ST A . 1 7 + 5 1 . 5 3 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 5 . 3 8 ST A . 1 9 + 5 3 . 4 3 EN D H O R I Z . D E F L E C T I O N BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 6 . 6 3 55.0' DEF. ST A . 1 4 + 0 6 . 9 4 T. O . P . = 4 9 7 4 . 8 9 ST A . 1 4 + 6 1 . 9 4 T. O . P . = 4 9 7 5 . 9 2 (@ 0.9°) 25.0' DEF. ST A . 1 8 + 9 0 . 7 9 T. O . P . = 4 9 7 6 . 0 6 ST A . 1 9 + 1 5 . 7 9 T. O . P . = 4 9 7 6 . 4 4 (@ 0.9°) 50.0' DEF. ST A . 1 2 + 3 3 . 0 7 T. O . P . = 4 9 7 3 . 5 2 ST A . 1 2 + 8 3 . 0 7 T. O . P . = 4 9 7 3 . 0 0 (@ 0.5°) 55.0' DEF. ST A . 1 3 + 3 0 . 9 0 T. O . P . = 4 9 7 2 . 9 8 ST A . 1 3 + 8 5 . 9 0 T. O . P . = 4 9 7 4 . 0 6 (@ 0.8°) 50.0' DEF. ST A . 1 8 + 0 8 . 9 3 T. O . P . = 4 9 7 4 . 8 7 ST A . 1 8 + 5 8 . 9 3 T. O . P . = 4 9 7 5 . 2 5 (@ 0.8°) 8" PVC STORM STA.=12+13.11 INV.=4977.18 8" PVC STORM STA.=12+15.64 INV.=4977.15 8" PVC STORM STA.=12+17.58 INV.=4977.19 8" PVC STORM STA.=12+11.22 INV.=4977.30 EXISTING GROUND PROPOSED GROUND 49 7 9 . 9 7 49 8 0 . 2 4 49 8 0 . 2 5 49 8 0 . 2 6 49 8 0 . 3 1 49 8 0 . 3 9 49 8 0 . 4 8 49 8 0 . 4 8 49 8 0 . 3 6 49 8 0 . 2 4 49 8 0 . 2 3 49 8 0 . 0 6 49 7 9 . 7 8 49 7 9 . 4 9 49 7 9 . 8 4 49 8 1 . 4 9 49 8 1 . 7 9 49 8 2 . 1 1 49 8 2 . 3 3 49 8 2 . 4 5 PROPOSED GROUND TOP OF PIPE 18" MIN. Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT2 PL A N & P R O F I L E WA T E R L I N E A 15 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: WATER LINE A ST A MA T C H L I N E SE E S H E E T 21 + 5 0 WT 3 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV L I N E MA T C H ST A 2 1 + 5 0 NORTH WT2 WT3 4965 4970 4975 4980 4985 4990 4995 5000 5005 4965 4970 4975 4980 4985 4990 4995 5000 5005 21+5022+0023+0024+0025+0026+0027+0028+0029+0030+0031+0032+00 24" RCP STORM STA.=29+16.36 INV.=4984.91 8" PVC ST A . 3 0 + 3 9 . 3 8" X 8 " T E E 2 - 8 " G V ( S W , S E ) T. O . P . = 4 9 8 5 . 9 0 ST A . 3 0 + 2 5 . 5 0. 0 ° D E F L E C T I O N T. O . P . = 4 9 8 4 . 3 7 ST A . 3 0 + 3 3 . 0 45 ° B E N D T. O . P . = 4 9 8 4 . 3 7 ST A . 3 0 + 3 4 . 5 45 ° B E N D T. O . P . = 4 9 8 5 . 8 6 ST A . 3 0 + 2 4 . 3 0. 1 ° D E F L E C T I O N T. O . P . = 4 9 8 4 . 3 7 ST A . 2 7 + 9 9 . 9 4 45 ° B E N D T. O . P . = 4 9 8 0 . 9 6 ST A . 2 8 + 6 1 . 7 7 45 ° B E N D T. O . P . = 4 9 8 1 . 2 5 ST A . 2 3 + 0 6 . 9 6 1 - 8 " G V BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 8 . 4 8 ST A . 2 2 + 5 6 . 3 6 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 8 . 2 1 ST A . 2 6 + 2 0 . 5 9 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 0 . 1 0 ST A . 2 4 + 0 4 . 8 7 RE V E R S E H O R I Z . D E F L E C T I O N T. O . P . = 4 9 7 8 . 9 9 84.0' DEF. ST A . 2 5 + 6 2 . 9 8 T. O . P . = 4 9 7 9 . 8 1 ST A . 2 6 + 4 6 . 9 3 T. O . P . = 4 9 8 0 . 2 3 (@ 0.0°) 55.0' DEF. ST A . 2 9 + 5 6 . 4 3 T. O . P . = 4 9 8 3 . 2 4 ST A . 3 0 + 1 1 . 3 8 T. O . P . = 4 9 8 4 . 3 5 (@ 0.8°) 75.0' DEF. ST A . 2 8 + 7 4 . 2 3 T. O . P . = 4 9 8 1 . 3 1 ST A . 2 9 + 4 9 . 2 3 T. O . P . = 4 9 8 2 . 9 6 (@ 0.5°) EXISTING GROUND PROPOSED GROUND 49 8 4 . 0 9 49 8 5 . 1 4 49 8 6 . 8 1 49 8 6 . 4 1 49 8 6 . 7 2 49 9 0 . 6 2 49 8 3 . 7 7 49 8 3 . 7 6 49 8 3 . 6 8 49 8 4 . 2 8 49 8 4 . 4 3 49 8 5 . 0 4 49 8 5 . 4 3 49 8 6 . 3 4 49 8 7 . 2 0 49 8 6 . 1 8 49 8 5 . 7 4 49 8 5 . 9 4 49 8 6 . 2 0 49 8 6 . 2 8 49 8 6 . 7 2 49 8 7 . 1 8 49 8 8 . 7 1 49 8 9 . 7 2 49 9 0 . 2 5 PROPOSED GROUND TOP OF PIPE ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 18" MIN. 8" PVC SANITARY STA.=30+29.28 INV.=4985.89 24" RCP STORM STA.=29+11.73 INV.=4984.91 X X X X X X X X X X X X X X X X X X X X X X UGEUGE UGE UGE UGE UG E UGE UGE UGE UGE UGE UGE UGEUG E UGEUGE U G E U G E U G E UG E UGE UGE U G E U G E U G E U G E U G E UGE UGE UGE UGE UGE VA U L T EL E C UD U D UD UD S S S S S S S S S S S S S S S S S S SS S S S W W W W W W W W W W W W W W W W W S S W W W W W W LOT 11LOT 10 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 TRACT A DE,UE,AE TRACT D LOT 3 LOT 8 LOT 10LOT 9LOT 7 LOT 1LOT 2LOT 4 BLOCK 3 BLOCK 6 LOT 14LOT 13LOT 12 40.48 LF 8" PVC N02°07'18"W 50.59 LF 8" PVC N24°54'24"E 1 7 9 . 3 6 L F 8 " P V C N 4 7 ° 2 4 ' 2 4 " E 61.83 LF 8" PVC N01°39'24"E 177.51 LF 8" PVC N44°36'54"W 1 6 1 .4 1 L F 8 "P V C R =3 0 0 .0 0 ' 3 0 2 .9 3 L F 8 "P V C R =3 0 0 .0 0 ' 97.91 LF 8"PVCR=300.00' 215.72 LF 8"PVCR=300.00' STA.=30+39.28 8"X8" TEE w/MJR 2 - 8" GV (SW, SE) N:138660.44 E:192070.77 STA.=28+61.77 45° BEND w/MJR N:138534.08 E:192195.44 STA.=27+99.94 45° BEND w/MJR N:138472.28 E:192193.65 STA.=26+20.59 END HORIZ. DEFLECTION STA.=24+04.87 REVERSE HORIZ. DEFLECTION STA.=23+06.96 BEGIN HORIZ. DEFLECTION STA.=17+92.01 BEGIN HORIZ. DEFLECTION STA.=19+53.43 BEGIN HORIZ. DEFLECTION STA.=19+53.43 END HORIZ. DEFLECTION STA.=22+56.36 END HORIZ. DEFLECTION STA.=23+06.96 1 - 8" GV N:138068.57 E:191940.27 EX I S T I N G 1 0 ' U T I L I T Y E A S E M E N T 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 15 ' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT SOFT GOLD PARK DOG PARK CITY OF FORT COLLINS IRRIGATION POND 6' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' UTILITY EASEMENT PROPOSED 10' CONCRETE TRAIL 50' NATURAL FEATURE BUFFER PROPOSED FOREBAY PROPOSED RAIN GARDEN A BIOMEDIA AREA PROPOSED 12' CONCRETE TRAIL PROPOSED CONCRETE TRAIL (WIDTH VARIES) PROPOSED FOREBAY PROPOSED UNDERGROUND ELECTRIC PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN 57' ROW 57' ROW 30' - 30' - 57' ROW 30' - 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) 40' UTILITY EASEMENT (BY SEPARATE DOCUMENT) SA I N T G R A C E S T R E E T SAINT THERESE STREET SAINT JEROME STREET ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 STORM DRAIN B SEE SHEET ST2 WATER LINE C SEE SHEET WT6 RG A UNDERDRAIN SEE SHEET U2WATER LINE B SEE SHEET WT4-WT5 PROFILE SCALE: WATER LINE A ST A MA T C H L I N E SE E S H E E T 21 + 5 0 WT 2 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT3 PL A N & P R O F I L E WA T E R L I N E A 16 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV LI N E MA T C H ST A 21 + 5 0 NORTH WT2 WT3 WT EL E C SS S MM W W W W W W W W W W WFO X G FO X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FO FO G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO G EEEEEE E OHU OHU OHU OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U OH U W W W W W W W W W W / / / / / / / / 12 " S S 12 " S S 12 " S S 12 " S S 12 " S S 12 " S S 12 " S S 12 " W 12 " W 12 " W 12 " W 12 " W 12 " W 12 " W 12 " W 12 " W 12 " W T 12 " S S 1 2 " S S 12" SS 12" SS 12" SS 12" SS 12" SS S S S S SS S S S S S S S S S S SSS S S S S S S S S S S S W W W W W W W W W W W W W W W WWW W W W W W W W WW WW W W W W S S S IR BLOCK 4 BLOCK 1 BLOCK 2 BLOCK 5 TRACT B DE TRACT C DE TRACT A DE,UE,AE LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 9 LOT 8 LOT 3LOT 2 LOT 4 LOT 5 LOT 6 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 7 LOT 1 LOT 1 LOT 2LOT 3 LOT 4LO T 6 LOT 8 LOT 7 LOT 5 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 16.88 LF 8" PVC R=300.00' 6 9 .3 5 L F 8 "P V C R =3 0 0 .0 0 ' ACKELSON CONNIE A. 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 9' UTILITY EASEMENT UT I L I T Y E A S E M E N T (W I D T H V A R I E S ) UT I L I T Y E A S E M E N T 15 ' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT WE S T W I L L O X L A N E 6' UTILIT Y E A S E M E N T 6' UTILITY E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 18 ' U T I L I T Y E A S E M E N T 18 ' U T I L I T Y E A S E M E N T SAINT THERESE STREET MO L L E R S T R E E T SA I N T J O S E P H S T R E E T PROPOSED FIRE HYDRANT PROPOSED 10' CONCRETE TRAIL EXISTING NCWA WATERLINE EXISTING NCWA WATERLINE EXISTING EDGE OF ASPHALT PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) EXISTING 6' CITY OF FORT COLLINS UTILITY EASEMENT 57' ROW 57' ROW 30' - 30' - 30' - 57' ROW 30' - ROW 30' - 72' ROW 126.90 LF 8" PVC S00°41'00"W 118.19 LF 8" PVC S00°45'03"W 14 4 . 1 8 L F 8 " P V C S8 9 ° 1 6 ' 0 5 " E 79 . 0 7 L F 8 " P V C S6 5 ° 0 3 ' 5 0 " E 67.28 LF 8" PVC S40°34'26"E 20.78 LF 8" PVC S16°05'02"E 97.68 LF 8" PVC S16°05'02"E 64.26 LF 8" PVC S12°51'35"E 144.14 LF 8" PVC S00°23'06"W STA.=10+00.00 12"X8" TEE w/MJR 1 - 12" GV (E) 1 - 8" GV (S) N:139646.55 E:191764.06 STA.=11+26.90 8"X6" TEE w/MJR 1 - 6" GV (E) 1 - FH ASSEMBLY (E) N:139519.65 E:191762.55 STA.=12+45.09 8"X8" TEE w/MJR 2 - 8" GV (S, E) N:139401.47 E:191761.00 STA.=13+89.28 22.5° BEND w/MRJ N:139399.63 E:191905.17 STA.=14+68.35 22.5° BEND w/MRJ N:139366.30 E:191976.87 STA.=15+35.63 22.5° BEND w/MRJ N:139315.19 E:192020.63 STA.=15+56.41 8"X6" TEE w/MJR 1 - 6" GV (SW) 1 - FH ASSEMBLY (SW) N:139295.22 E:192026.39 STA.=16+54.09 BEGIN HORIZ. DEFLECTION STA.=16+70.97 END HORIZ. DEFLECTION STA.=17+35.22 BEGIN HORIZ. DEFLECTION STA.=18+04.57 END HORIZ. DEFLECTION SANITARY LINE A4 SEE SHEET WT2-WT3 SANITARY LINE A SEE SHEET SS1 SANITARY LINE A7 SEE SHEET SS4 WILLOX WATER LINE SEE SHEET WT1 WATER LINE D SEE SHEET WT7 WILLOX EAST STORM DRAIN SEE SHEET ST3 SANITARY LINE A SEE SHEET SS1 EXISTING WATER CROSSING STA.=10+40.41 PROPOSED 2" IRRIGATION METER 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0018+50 8" PVC 8" PVC ST A . 1 0 + 0 0 . 0 12 " x 8 " T E E T. O . P . = 4 9 8 7 . 2 5 ST A . 1 2 + 4 5 . 1 0. 3 ° D E F L E C T I O N T. O . P . = 4 9 8 7 . 1 8 ST A . 1 5 + 4 4 . 6 0. 8 ° D E F L E C T I O N T. O . P . = 4 9 8 4 . 8 1 ST A . 1 0 + 3 2 . 9 45 ° B E N D T. O . P . = 4 9 8 6 . 7 5 ST A . 1 0 + 3 5 . 4 45 ° B E N D T. O . P . = 4 9 8 4 . 3 3 ST A . 1 0 + 4 5 . 4 45 ° B E N D T. O . P . = 4 9 8 4 . 3 3 ST A . 1 0 + 4 8 . 7 45 ° B E N D T. O . P . = 4 9 8 7 . 6 9 ST A . 1 1 + 2 6 . 9 0 8" X 6 " T E E 1 - 6 " G V ( E ) 1 - F H A S S E M B L Y ( E ) T. O . P . = 4 9 8 8 . 4 7 ST A . 1 2 + 4 5 . 0 9 8" X 8 " T E E 2 - 8 " G V ( S , E ) T. O . P . = 4 9 8 7 . 1 8 ST A . 1 3 + 8 9 . 2 8 22 . 5 ° B E N D T. O . P . = 4 9 8 6 . 0 4 ST A . 1 4 + 6 8 . 3 5 22 . 5 ° B E N D T. O . P . = 4 9 8 5 . 4 1 ST A . 1 5 + 3 5 . 6 3 22 . 5 ° B E N D T. O . P . = 4 9 8 4 . 8 8 ST A . 1 5 + 5 6 . 4 1 8" X 6 " T E E 1 - 6 " G V ( S W ) 1 - F H A S S E M B L Y ( S W ) T. O . P . = 4 9 8 4 . 8 9 ST A . 1 6 + 5 4 . 0 9 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 5 . 5 4 ST A . 1 7 + 3 5 . 2 2 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 6 . 0 8 ST A . 1 6 + 7 0 . 9 7 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 5 . 6 5 ST A . 1 8 + 0 4 . 5 7 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 6 . 5 5 75.0' DEF. ST A . 1 0 + 8 9 . 4 0 T. O . P . = 4 9 8 8 . 2 3 ST A . 1 1 + 6 4 . 4 0 T. O . P . = 4 9 8 8 . 2 3 (@ 0.4°) PROPOSED GROUND EXISTING GROUND 49 9 2 . 5 4 49 9 2 . 9 0 49 9 2 . 3 4 49 9 1 . 2 9 49 9 0 . 5 6 49 8 9 . 9 1 49 9 0 . 0 1 49 9 0 . 6 0 49 9 1 . 1 2 49 9 1 . 9 4 49 9 2 . 2 4 49 9 2 . 6 3 49 9 3 . 0 1 49 9 2 . 9 4 49 9 2 . 7 0 49 9 1 . 9 9 49 9 1 . 6 5 49 9 1 . 3 4 49 9 1 . 0 7 49 9 0 . 8 6 49 9 0 . 7 3 49 9 0 . 3 4 49 9 0 . 2 0 49 9 0 . 1 0 49 8 9 . 7 5 49 8 9 . 6 1 49 8 9 . 8 2 49 9 0 . 1 8 49 9 0 . 3 3 49 9 0 . 4 7 49 9 0 . 7 2 49 9 0 . 8 4 49 9 0 . 9 7 49 9 1 . 2 5 PROPOSED GROUND TOP OF PIPE CO N T R A C T O R T O V E R I F Y LO C A T I O N P R I O R T O CO N S T R U C T I O N . EXISTING 4" PVC NOCO WATER STA.=10+40.41 TOP=4986.17 18" MIN. Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT4 PL A N & P R O F I L E WA T E R L I N E B 17 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: WATER LINE B ST A MA T C H L I N E SE E S H E E T 18 + 5 0 WT 5 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV LI N E MA T C H ST A 18 + 5 0 NORTH WT4 WT5 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 18+5019+0020+0021+0022+0022+50 8" PVC 8" PVC ST A . 2 2 + 0 0 . 3 8" X 8 " T E E 2 - 8 " G V ( S W , S E ) T. O . P . = 4 9 8 5 . 9 0 ST A . 1 9 + 4 8 . 7 0. 3 ° D E F L E C T I O N T. O . P . = 4 9 8 7 . 3 7 ST A . 1 9 + 4 8 . 7 1 8" X 6 " T E E 1 - 8 " G V ( S ) 1 - 6 " G V ( W ) 1 - F H A S S E M B L Y ( W ) T. O . P . = 4 9 8 7 . 3 7 ST A . 2 1 + 9 1 . 7 1 45 ° B E N D T. O . P . = 4 9 8 5 . 9 5 20.0' DEF. ST A . 1 8 + 7 8 . 4 0 T. O . P . = 4 9 8 7 . 1 9 ST A . 1 8 + 9 8 . 4 0 T. O . P . = 4 9 8 7 . 3 7 (@ 1.0°) 20.0' DEF. ST A . 1 8 + 5 4 . 3 5 T. O . P . = 4 9 8 6 . 8 8 ST A . 1 8 + 7 4 . 3 5 T. O . P . = 4 9 8 7 . 1 2 (@ 0.6°) PROPOSED GROUND EXISTING GROUND 49 9 1 . 6 2 49 9 1 . 6 8 49 9 1 . 1 8 49 9 0 . 4 0 49 9 1 . 5 0 49 9 1 . 7 5 49 9 1 . 8 0 49 9 1 . 7 8 49 9 1 . 5 5 49 9 1 . 4 3 49 9 1 . 3 0 49 9 1 . 0 2 49 9 0 . 8 4 49 9 0 . 6 4 TOP OF PIPE 18" MIN. 12" PVC SANITARY STA.=19+05.21 INV.=4984.17 WW T WXXXXXX 12 " S S 12 " S S 12 " S S 12" SS 12" SS UD U D UD UD S S SSS S S S S S S S S S SS S S S S W WWW W W W W W W W W W W W WW W W W LOT 11 LOT 10 LOT 9 LOT 1 LOT 2 LOT 3 LOT 4 TRACT A DE,UE,AE TRACT D LOT 8 LOT 10 LOT 9 LOT 7 BLOCK 3 BLOCK 6 LOT 14 LOT 13 LOT 12 BLOCK 5 LOT 14 LO T 6 LOT 6 LOT 8 LOT 7 LOT 5 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 6' UTILITY EASEMENT 6' UTILITY EASEMENT 6' UTILITY EASEMENT SAINT JEROME STREET MO L L E R S T R E E T SA I N T G R A C E S T R E E T PROPOSED 10' CONCRETE TRAIL PROPOSED 10' CONCRETE TRAIL PROPOSED FOREBAY PROPOSED RAIN GARDEN B BIOMEDIA AREA PROPOSED FOREBAY PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN w/ 6" CURBS PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN 57' ROW 30' - 30' - 57' ROW 30' - 30' - 144.14 LF 8" PVC S00°23'06"W 243.00 LF 8" PVC S00°23'06"W 8.59 LF 8" PVC S45°23'06"W STA.=18+04.57 END HORIZ. DEFLECTION STA.=19+48.71 8"X6" TEE w/MJR 1 - 8" GV (S) 1 - 6" GV (W) 1 - FH ASSEMBLY (W) N:138909.46 E:192078.52 STA.=21+91.71 45° BEND w/MJR N:138666.47 E:192076.88 STA.=22+00.29 8"X8" TEE w/MJR 2 - 8" GV (SW, SE) N:138660.44 E:192070.77 SANITARY LINE A6 SEE SHEET SS3 STORM DRAIN B SEE SHEET ST2 WATER LINE A SEE SHEET WT2-WT3 WATER LINE C SEE SHEET WT6 BLOCK 2 SANITARY LINE A SEE SHEET SS1 PROFILE SCALE: WATER LINE B KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV LI N E MA T C H ST A 18 + 5 0 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT5 PL A N & P R O F I L E WA T E R L I N E B 18 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 NORTH ST A MA T C H L I N E SE E S H E E T 18 + 5 0 WT 4 WT4 WT5 X X X X X X X X X X X X X X X X X X X 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12 " S S UD U D S S S S S S S S S S S S S SS SSSS S S S S S S S S W W W W W W W W WWW W W W W W W W W W W W W W W W S S SS W W WW WW UD LOT 11 LOT 10 LOT 9 LOT 10 LOT 1 LOT 2LOT 3LOT 4LOT 5LOT 6 LOT 12 LOT 11 LOT 8 LOT 9 LOT 7 TRACT DLOT 3 LOT 8 LOT 10 LOT 9 LOT 7 LOT 1 LOT 2 LOT 4 BLOCK 3 BLOCK 6 LOT 14 LOT 13 LOT 12 BLOCK 2 LOT 6LOT 5 LOT 8 LOT 7 LOT 13 98.50 LF 8" PVC S00°23'06"W 18 8 . 0 0 L F 8 " P V C S0 0 ° 2 3 ' 0 6 " W 43.14 LF 8" PVC S44°36'54"E 243.13 LF 8" PVC S89°36'54"E 17.12 LF 8" PVC S89°36'54"E 20.41 LF 8" PVC N45°23'06"E 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT 9' UTILITY EASEMENT UTILITY EASEMENT 15' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T SA I N T T H E R E S E S T R E E T SA I N T J E R O M E S T R E E T MOLLER STREET MOLLER STREET SAINT GRACE STREET FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE PROPOSED FOREBAY PROPOSED FOREBAY PROPOSED A RAIN GARDEN BIOMEDIA AREA PROPOSED FOREBAY PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN EXISTING 20' DRAINAGE EASEMENT 57' ROW 57' ROW 30' - 30' - 57' ROW 30' - 57' ROW 30' - 57' ROW 30' -STA.=10+04.66 8"X6" TEE w/MJR 1 - 8" GV (W) 1 - 6" GV (N) 1 - FH ASSEMBLY (N) N:138966.06 E:191618.12 PITT, JEAN GBP LLC STA.=10+00.00 8" STUB RESTRAIN TO TEE (E) N:138966.09 E:191613.46 STA.=11+54.16 8"X8" TEE w/MJR 2 - 8" GV (S, W) N:138965.05 E:191767.62 STA.=12+52.66 8"X6" TEE w/MJR 1 - 6" GV (E) 1 - FH ASSEMBLY (E) N:138866.56 E:191766.96 STA.=14+40.66 45° BEND w/MJR N:138678.56 E:191765.69 STA.=14+83.80 45° BEND w/MJR N:138647.86 E:191795.99 STA.=17+26.93 8"X6" TEE w/MJR 1 - 8" GV (W) 1 - 6" GV (S) 1 - FH ASSEMBLY (S) N:138646.22 E:192039.12 STA.=17+64.47 8"X8" TEE w/MJR 2 - 8" GV (SW, SE) N:138660.44 E:192070.77 STA.=17+44.06 45° BEND w/MJR N:138646.11 E:192056.24 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 SANITARY LINE A SEE SHEET SS1 SANITARY LINE A6 SEE SHEET SS3 STORM DRAIN A SEE SHEET ST1 STORM DRAIN B SEE SHEET ST2 WATER LINE A SEE SHEET WT2-WT3 WATER LINE B SEE SHEET WT4-WT5 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 8" PVC 8" PVC ST A . 1 0 + 0 0 . 0 8" S T U B RE S T R A I N T O T E E ( E ) T. O . P . = 4 9 8 7 . 0 6 ST A . 1 0 + 1 4 . 3 45 ° B E N D T. O . P . = 4 9 8 4 . 7 2 ST A . 1 0 + 2 1 . 8 45 ° B E N D T. O . P . = 4 9 8 4 . 7 2 ST A . 1 0 + 2 4 . 1 45 ° B E N D T. O . P . = 4 9 8 7 . 0 0 ST A . 1 1 + 5 6 . 2 45 ° B E N D T. O . P . = 4 9 8 7 . 6 7 ST A . 1 1 + 6 0 . 4 45 ° B E N D T. O . P . = 4 9 8 3 . 4 2 ST A . 1 1 + 6 7 . 9 45 ° B E N D T. O . P . = 4 9 8 3 . 4 2 ST A . 1 1 + 7 1 . 6 45 ° B E N D T. O . P . = 4 9 8 7 . 0 6 ST A . 1 0 + 1 2 . 1 45 ° B E N D T. O . P . = 4 9 8 6 . 9 9 ST A . 1 4 + 4 1 . 1 0. 0 ° D E F L E C T I O N T. O . P . = 4 9 8 6 . 1 1 ST A . 1 4 + 6 8 . 6 0. 0 ° D E F L E C T I O N T. O . P . = 4 9 8 6 . 1 1 ST A . 1 7 + 6 4 . 5 8" X 8 " T E E 2 - 8 " G V ( S W , S E ) T. O . P . = 4 9 8 5 . 9 0 ST A . 1 2 + 5 2 . 6 6 8" X 6 " T E E 1 - 6 " G V ( E ) 1 - F H A S S E M B L Y ( E ) T. O . P . = 4 9 8 8 . 5 0 ST A . 1 4 + 4 0 . 6 6 45 ° B E N D T. O . P . = 4 9 8 6 . 1 1 ST A . 1 4 + 8 3 . 8 0 45 ° B E N D T. O . P . = 4 9 8 6 . 1 0 ST A . 1 7 + 2 6 . 9 3 8" X 6 " T E E 1 - 8 " G V ( W ) 1 - 6 " G V ( S ) 1 - F H A S S E M B L Y ( S ) T. O . P . = 4 9 8 5 . 9 3 ST A . 1 7 + 4 4 . 0 6 45 ° B E N D T. O . P . = 4 9 8 5 . 9 1 ST A . 1 0 + 0 4 . 6 6 8" X 6 " T E E 1 - 8 " G V ( W ) 1 - 6 " G V ( N ) 1 - F H A S S E M B L Y ( N ) T. O . P . = 4 9 8 7 . 0 4 ST A . 1 1 + 5 4 . 1 6 8" X 8 " T E E 2 - 8 " G V ( S , W ) T. O . P . = 4 9 8 7 . 6 6 155.5' DEF. ST A . 1 1 + 7 4 . 9 3 T. O . P . = 4 9 8 7 . 1 7 ST A . 1 3 + 3 0 . 4 0 T. O . P . = 4 9 8 7 . 6 4 (@ 0.4°) 92.7' DEF. ST A . 1 3 + 4 4 . 6 9 T. O . P . = 4 9 8 7 . 2 8 ST A . 1 4 + 3 7 . 4 2 T. O . P . = 4 9 8 6 . 1 1 (@ 0.3°) 30" RCP STORM STA.=10+18.08 INV.=4986.79 12" PVC SANITARY STA.=11+64.16 INV.=4984.95 8" PVC SANITARY STA.=14+54.80 INV.=4987.63 PROPOSED GROUND EXISTING GROUND 18" MIN. 18" MIN. 18" MIN. ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 49 9 1 . 5 6 49 9 1 . 5 0 49 9 1 . 6 1 49 9 1 . 7 3 49 9 1 . 8 6 49 9 1 . 9 8 49 9 2 . 1 1 49 9 2 . 1 1 49 9 2 . 3 0 49 9 2 . 7 2 49 9 3 . 0 1 49 9 3 . 1 6 49 9 3 . 2 2 49 9 3 . 1 9 49 9 3 . 0 8 49 9 2 . 9 5 49 9 2 . 7 6 49 9 2 . 5 8 49 9 2 . 5 2 49 9 2 . 2 2 49 9 2 . 0 1 49 9 1 . 8 2 49 9 1 . 6 4 49 9 1 . 4 8 49 9 1 . 3 6 49 9 1 . 2 3 49 9 1 . 1 1 49 9 0 . 9 6 49 9 0 . 7 8 49 9 0 . 5 6 49 9 0 . 2 9 PROPOSED GROUND TOP OF PIPE Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT6 PL A N & P R O F I L E WA T E R L I N E C 19 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: WATER LINE C KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV NORTH WT6 W W X X X X XXXXXXXXXX X XX FO FO FO FO FO FO FO G G G G G G G FO FO FO FO FO FO OH U OH U OH U OH U OH U OH U W W W W W W / / / / / / / / 12 " S S 12 " S S 12 " S S 12 " S S 12 " W 12 " W 12 " W 12 " W 12 " W S S S S S S S S S S S S S W W W W W W W W WW WW W W W W S S S IR BLOCK 4 BLOCK 1 BLOCK 5 TRACT B DE TRACT C DE LOT 1 LOT 2 LOT 3 LOT 8 LOT 3LOT 2 LOT 4 LOT 5 LOT 6 LOT 7 LOT 1 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 9' UTILITY EASEMENT UT I L I T Y E A S E M E N T (W I D T H V A R I E S ) 9' U T I L I T Y E A S E M E N T UT I L I T Y E A S E M E N T UT I L I T Y E A S E M E N T 15 ' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT WE S T W I L L O X L A N E 6' UTILITY EASEMENT 6' UTILITY EASEMENT 18 ' U T I L I T Y E A S E M E N T SAINT THERESE STREET MO L L E R S T R E E T SA I N T J O S E P H S T R E E T PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING NCWA WATERLINE FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) PROPOSED 4' CONCRETE PAN w/ 7" CURBS PROPOSED 2' CONCRETE PAN 57' ROW 30' - 57' ROW 57' ROW 30' - 72' ROW 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE KAFKA, AMY PROPOSED FIRE HYDRANT 57' ROW 30' - 65.02 LF 8" PVC S00°33'38"W104.53 LF 8" PVC S02°13'27"E 29.70 LF 8" PVC S00°23'06"W 12 7 .18 L F 8 "P V C R =2 5 0 5 .0 0 '110.12 LF 8 "P V C R =2 4 9 5 .0 0 ' STA.=10+00.00 8"X8" TEE w/MJR 2 - 8" GV (S, E) N:139401.47 E:191761.00 STA.=10+65.02 BEGIN HORIZ. DEFLECTION STA.=11+92.20 END HORIZ. DEFLECTION STA.=12+96.73 8"X6" TEE w/MJR 1 - 6" GV (W) 1 - FH ASSEMBLY (W) N:139104.85 E:191766.13 STA.=12+96.73 BEGIN HORIZ. DEFLECTION STA.=14+06.85 END HORIZ. DEFLECTION STA.=14+36.55 8"X8" TEE w/MJR 2 - 8" GV (S, W) N:138965.05 E:191767.62 SANITARY LINE A4 SEE SHEET WT2-WT3 SANITARY LINE A7 SEE SHEET SS4 WILLOX STORM DRAIN SEE SHEET ST3STORM DRAIN A SEE SHEET ST1 WILLOX WATER LINE SEE SHEET WT1 WATER LINE B SEE SHEET WT4-WT5 WATER LINE C SEE SHEET WT6 SANITARY LINE A7 SEE SHEET SS4 PROPOSED 2" IRRIGATION METER 4975 4980 4985 4990 4995 5000 5005 5010 5015 4975 4980 4985 4990 4995 5000 5005 5010 5015 9+5010+0011+0012+0013+0014+0014+80 8" PVC 8" PVC 8" PVC ST A . 1 0 + 0 0 . 0 8" X 8 " T E E 2 - 8 " G V ( S , E ) T. O . P . = 4 9 8 7 . 1 8 ST A . 1 4 + 3 6 . 6 8" X 8 " T E E 2 - 8 " G V ( S , W ) T. O . P . = 4 9 8 7 . 1 1 ST A . 1 2 + 8 2 . 9 0. 3 ° D E F L E C T I O N T. O . P . = 4 9 8 8 . 6 3 ST A . 1 0 + 6 5 . 0 2 BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 7 . 5 1 ST A . 1 2 + 9 6 . 7 3 8" X 6 " T E E 1 - 6 " G V ( W ) 1 - F H A S S E M B L Y ( W ) BE G I N H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 8 . 6 3 ST A . 1 1 + 9 2 . 2 0 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 8 . 1 7 ST A . 1 4 + 0 6 . 8 5 EN D H O R I Z . D E F L E C T I O N T. O . P . = 4 9 8 7 . 7 1 75.0' DEF. ST A . 1 3 + 2 6 . 1 7 T. O . P . = 4 9 8 8 . 6 1 ST A . 1 4 + 0 1 . 1 7 T. O . P . = 4 9 8 7 . 8 3 (@ 0.3°) PROPOSED GROUND EXISTING GROUND Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 WT7 PL A N & P R O F I L E WA T E R L I N E D 20 ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: WATER LINE D KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES, WATER & WASTE WATER DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 5.PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 11.PVC - PIPE JOINT DEFLECTION FOR PVC PIPE SHALL NOT EXCEED 1 DEGREE PER SECTION OF PIPE. BENDING OF THE PIPE IS NOT ALLOWED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV NORTH WT7 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+50 10+00 11+00 12+00 13+00 14+00 15+00 48.78 LF 36" RCP @ 0.20% FE S A ST A 1 0 + 0 0 . 0 0 IN V . 4 9 8 4 . 7 4 ( N ) 75.57 LF 36" RCP @ 0.20% ST M H A 1 ST A 1 0 + 4 8 . 7 8 RI M 4 9 9 0 . 5 ± IN V . I N 4 9 8 4 . 8 4 ( N ) IN V . O U T 4 9 8 4 . 8 4 ( S ) TE E A 2 ST A 1 1 + 2 4 . 3 5 IN V . 4 9 8 4 . 9 9 ( N ) IN V . 4 9 8 6 . 1 6 ( E ) IN V . 4 9 8 4 . 9 9 ( S ) 112.53 LF 36" RCP @ 0.20% TE E A 3 ST A 1 2 + 3 6 . 8 8 IN V . 4 9 8 5 . 2 2 ( N ) IN V . 4 9 8 6 . 4 0 ( E ) IN V . 4 9 8 5 . 2 2 ( S ) 87.14 LF 36" RCP @ 0.20% 31.87 LF 30" RCP @ 2.65% ST M H A 4 ST A 1 3 + 2 4 . 0 2 RI M 4 9 9 0 . 6 ± IN V . I N 4 9 8 5 . 9 0 ( N E ) IN V . O U T 4 9 8 5 . 3 9 ( S ) 30.00 LF 30" RCP @ 0.20% IN L E T A 5 ST A 1 3 + 5 5 . 8 8 RI M 4 9 9 1 . 2 ± IN V . I N 4 9 8 6 . 7 4 ( N ) IN V . O U T 4 9 8 6 . 7 4 ( S W ) IN L E T A 6 ST A 1 3 + 8 5 . 8 8 RI M 4 9 9 1 . 2 ± IN V . I N 4 9 8 6 . 8 0 ( N ) IN V . O U T 4 9 8 6 . 8 0 ( S ) 36.45 LF 24" RCP @ 0.20% FE S A 7 ST A 1 4 + 2 2 . 3 3 IN V . 4 9 8 6 . 8 7 ( S ) 8" PVC WATER STA.=13+80.89 TOP=4984.72 12" PVC SANITARY STA.=13+70.88 INV.=4985.25 2.5" ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 PROPOSED GROUND EXISTING GROUND XXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXX 12 " S S 12 " S S 12 " S S 12 " S S UD S S SSS S W W W W W W W W S S W UD UD UD / / / / / / / / LOT 10 LOT 12LOT 11 LOT 8 LOT 13 LOT 9 LOT 7 LOT 1 LOT 2 LOT 3 TRACT B DE TRACT A DE,UE,AE BLOCK 3 BLOCK 4 57' ROW 3 0 ' I R R I G A T I O N E A S E M E N T FO R F U T U R E C I T Y O F F O R T C O L L I N S PA R K S D E P T . I R R I G A T I O N L I N E 3 0 ' I R R I G A T I O N E A S E M E N T FO R F U T U R E C I T Y O F F O R T C O L L I N S PA R K S D E P T . I R R I G A T I O N L I N E 5' S I D E W A L K 5' S I D E W A L K UT I L I T Y E A S E M E N T 15 ' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' UTILITY EASEMENT WATER LINE C SEE SHEET WT6 FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) PROPOSED FOREBAY PROPOSED RAIN GARDEN B BIOMEDIA AREA 4' CONCRETE PAN w/ 7" CURBS PROPOSED INLET (SEE SHEET U2 SMALL PIPE HEADWALL (SEE DETAIL) RG B UNDERDRAIN SEE SHEET U2 INLET A5 STA 13+55.88 N: 138940.97 E: 191631.24 INLET A6 STA 13+85.88 N: 138970.97 E: 191631.60 STMH A4 STA 13+24.02 N: 138912.57 E: 191616.80 STMH A1 STA 10+48.78 N: 138637.35 E: 191613.51 FES A7 STA 14+22.33 N: 139005.68 E: 191620.46 TEE A3 STA 12+36.88 N: 138825.43 E: 191615.76 TEE A2 STA 11+24.35 N: 138712.91 E: 191614.41 FES A STA 10+00.00 N: 138589.76 E: 191624.21 36.45 LF 24" RCP @ 0.20% 87.14 LF 36" RCP @ 0.20% 30.00 LF 30" RCP @ 0.20% 48.78 LF 36" RCP @ 0.20% 31.87 LF 30" RCP @ 2.65% 75.57 LF 36" RCP @ 0.20% 112.53 LF 36" RCP @ 0.20% 30' FL-FL PROPOSED INLET (SEE SHEET U2 SANITARY LINE A SEE SHEET SS1 MO L L E R S T R E E T ENCASE 20 LF SANITARY IN CONCRETE PER FORT COLLINS DETAIL WW-6 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ST1 PL A N & P R O F I L E ST O R M D R A I N A 21 STORM DRAIN A6 PROFILE SCALE: STORM DRAIN A CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 6.CONCRETE FORBAYS SHALL NOT BE CONSTRUCTED ON RAIN GARDEN BIOMEDIA SOIL. CONTRACTOR SHALL ENSURE FORBAYS ARE CONSTRUCTED ON COMPACTED NATIVE SOIL. PROPOSED RIGHT OF WAY INLET SCHEDULE: ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 NORTH 4965 4970 4975 4980 4985 4990 4995 5000 5005 4965 4970 4975 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 FE S B 1 - A & B 1 - B ST A 1 0 + 0 0 . 0 0 IN V . 4 9 8 4 . 8 9 ( N E ) FE S B 2 - A & B 2 - B ST A 1 0 + 4 3 . 1 5 IN V . 4 9 8 4 . 9 8 ( S W ) 43.15 LF 2 - 24" RCP @ 0.20% 8" PVC WATER STA.=10+06.28 TOP=4981.87 2.73' W T W X X X X X X UGE UG E U G E U G E U G E U G E UGE U G E VAU L TELE C UD UD U D U D S S S S W W W W W LOT 1 LOT 13 LOT 14 TRACT A DE,UE,AE BLOCK 3 BLOCK 2 BLOCK 6 PROPOSED 10' CONCRETE TRAIL PROPOSED FOREBAY PROPOSED RAIN GARDEN A BIOMEDIA AREA PROPOSED FOREBAY PROPOSED 4' SIDEWALK CULVERT SAINT GRACE STREET SA I N T J E R O M E ST R E E T FES B1-A STA 10+00.00 N: 138568.19 E: 192152.85 FES B2-A STA 10+43.15 N: 138600.33 E: 192181.65 43.15 LF 24" RCP @ 0.20% FES B1-B STA 10+00.00 N: 138565.04 E: 192156.23 43.15 LF 24" RCP @ 0.20% FES B2-B STA 10+43.94 N: 138597.18 E: 192185.03 WATER LINE A SEE SHEET WT3 PROPOSED 4' CONCRETE PAN w/ 6" CURBS RG A UNDERDRAIN SEE SHEET U2 4965 4970 4975 4980 4985 4990 4995 5000 5005 4965 4970 4975 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 43.09 LF 15" RCP @ 0.20% FE S C ST A 1 0 + 0 0 . 0 0 IN V . 4 9 8 2 . 8 9 ( N E ) OU T L E T C 2 ST A 1 0 + 4 3 . 0 9 IN V . 4 9 8 2 . 9 8 ( E ) IN V . 4 9 8 2 . 9 8 ( S W ) FUTURE 15" HDPE IRRIGATION (BY OTHERS) STA.=10+12.76 INV.=4980.42 12" X X X X X X X X X X X X UD TRACT A DE,UE,AE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' DRAINAGE EASEMENT (BY SEPARATE DOCUMENT) EXISTING 10' UTILITY EASEMENT CITY OF FORT COLLINS IRRIGATION POND 50' NATURAL FEATURE BUFFER FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) PROPOSED OUTLET STRUCTURE PROPOSED RAIN GARDEN B BIOMEDIA AREA PROPOSED 2' CONCRETE PAN SMALL PIPE HEADWALL (SEE DETAIL) OUTLET C2 STA 10+43.09 N: 138379.46 E: 191652.57 FES C STA 10+00.00 N: 138352.89 E: 191618.65 43.09 LF 15" RCP @ 0.20% RG A UNDERDRAIN SEE SHEET U2 DETENTION POND EMERGENCY OVERFLOW WEIR Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ST2 PL A N & P R O F I L E ST O R M D R A I N S B & C 22 STORM DRAIN B PROFILE SCALE: STORM DRAIN B CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 6.CONCRETE FORBAYS SHALL NOT BE CONSTRUCTED ON RAIN GARDEN BIOMEDIA SOIL. CONTRACTOR SHALL ENSURE FORBAYS ARE CONSTRUCTED ON COMPACTED NATIVE SOIL. PROPOSED RIGHT OF WAY INLET SCHEDULE: ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 NORTH STORM DRAIN C STORM DRAIN C PROFILE SCALE: 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+00 14.09 LF 15" RCP @ 0.35% FE S W 2 ST A 1 0 + 4 5 . 7 9 IN V . 4 9 8 9 . 9 3 ( E ) ST M H W 1 ST A 1 0 + 3 1 . 7 0 RI M 4 9 9 3 . 0 ± IN V . I N 4 9 8 9 . 8 8 ( W ) IN V . O U T 4 9 8 9 . 8 8 ( S ) 31.70 LF 15" RCP @ 0.35% FE S W ST A 1 0 + 0 0 . 0 0 IN V . 4 9 8 9 . 7 7 ( N ) PROPOSED GROUND EXISTING GROUND EXISTING 4" PVC WATER STA.=10+21.47 TOP=4986.38 MS W W FO FO FO XXXXXX / / / / / / / / / / / / / / / / G G G OHU OHU OHU FO FO FO / / / / / / / // / / / / / / // / / / / / / // / / / / / / / W W W W W W W WXXXXXXX X X X X X X X X X FO FO FO FO FO G G G G G / / / / / / / // / / / / / / // / / / / / / // / / / / / / /FO FO FO FO OHU OHU OHU OHU OHU OHU W W W W W W W W 12" W 12" W 12" W 12" W UGE UGE UGE UGE UGE / / / / / / / / / / / / / / / / TRACT B DE EXISTING 30' NCWA UTILITY EASEMENT 72' ROW EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 9' U T I L I T Y E A S E M E N T WEST WILLOX LANE 18' UTILITY EASEMENT WILLOX WATER LINE SEE SHEET WT1 EXISTING NCWA WATERLINE FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) PROPOSED FIRE HYDRANT ±41' FL- EOP STMH W1 STA 10+31.70 N: 139617.51 E: 191615.20 FES W2 STA 10+45.79 N: 139617.69 E: 191601.12 FES W STA 10+00.00 N: 139585.81 E: 191614.83 14.09 LF 15" RCP @ 0.35% 31.70 LF 15" RCP @ 0.35% PROPOSED 4' CONCRETE PAN w/ 7" CURBS EXISTING FIBER OPTIC TO BE RELOCATED Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ST3 PL A N & P R O F I L E WI L L O X S T O R M D R A I N 23 WILLOX STORM DRAIN PROFILE SCALE: WILLOX STORM DRAIN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 6.CONCRETE FORBAYS SHALL NOT BE CONSTRUCTED ON RAIN GARDEN BIOMEDIA SOIL. CONTRACTOR SHALL ENSURE FORBAYS ARE CONSTRUCTED ON COMPACTED NATIVE SOIL. PROPOSED RIGHT OF WAY INLET SCHEDULE: ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 NORTH 4970 4975 4980 4985 4990 4995 5000 5005 5010 4970 4975 4980 4985 4990 4995 5000 5005 5010 9+5010+0011+0012+0013+0014+0015+0016+00 PROPOSED GROUND EXISTING GROUND 78.04 LF 12" HDPE @ 0.20% FE S E ST A 1 0 + 0 0 . 0 0 IN V . 4 9 8 7 . 0 0 ( N W ) 28.79 LF 12" HDPE @ 0.20% BE N D E 1 w C O ST A 1 0 + 7 8 . 0 4 RI M 4 9 8 9 . 7 ± IN V . I N 4 9 8 7 . 1 6 ( W ) IN V . O U T 4 9 8 7 . 1 6 ( S E ) BA S I N E 2 ST A 1 1 + 0 6 . 8 3 RI M 4 9 8 9 . 6 ± IN V . I N 4 9 8 7 . 4 1 ( N ) IN V . I N 4 9 8 7 . 2 1 ( W ) IN V . O U T 4 9 8 7 . 2 1 ( E ) 78.68 LF 12" HDPE @ 0.20% 13.54 LF 12" HDPE @ 0.20% BE N D E 3 ST A 1 1 + 8 5 . 5 2 IN V . 4 9 8 7 . 3 7 ( N W ) IN V . 4 9 8 7 . 3 7 ( E ) BE N D E 4 w C O ST A 1 1 + 9 9 . 0 5 RI M 4 9 8 9 . 8 ± IN V . I N 4 9 8 7 . 4 0 ( N ) IN V . O U T 4 9 8 7 . 4 0 ( S E ) 291.93 LF 12" HDPE @ 0.50% 35.14 LF 12" HDPE @ 1.20% BA S I N E 5 ST A 1 4 + 9 0 . 9 8 RI M 4 9 9 3 . 0 ± IN V . I N 4 9 8 8 . 8 6 ( E ) IN V . O U T 4 9 8 8 . 8 6 ( S ) FE S E 6 ST A 1 5 + 2 6 . 1 2 IN V . 4 9 8 9 . 2 8 ( W ) 12" PVC SANITARY STA.=10+60.04 INV.=4982.28 EXISTING 4" PVC WATER STA.=14+81.42 TOP=4985.98 W WWW S X X X X X X X X X E E E E E E E E E E E E W W W W 12" SS 12" SS 12" SS 12" S S 12" SS 12" SS 1 2 " S S S S S S W W W W W LOT 1 LOT 9 LOT 5 LOT 4 TRACT A DE,UE,AE BLOCK 5 BLOCK 2 EXISTING 6' CITY OF FORT COLLINS UTILITY EASEMENT PROPOSED FIRE HYDRANT EXISTING SSMH PROPOSED 4' SIDEWALK CHASE PROPOSED 2' SIDEWALK CHASE PROPOSED 4' SIDEWALK CULVERT 78.04 LF 12" HDPE @ 0.20% 28.79 LF 12" HDPE @ 0.20% 78.68 LF 12" HDPE @ 0.20% 13.54 LF 12" HDPE @ 0.20% 291.93 LF 12" HDPE @ 0.50% BEND E4 w CO STA 11+99.05 N: 139321.91 E: 192075.49 BEND E3 STA 11+85.52 N: 139312.19 E: 192084.92 BASIN E2 STA 11+06.83 N: 139311.17 E: 192163.60 BEND E1 w CO STA 10+78.04 N: 139310.80 E: 192192.38 FES E STA 10+00.00 N: 139266.61 E: 192256.71 SANITARY LINE A SEE SHEET SS1 FES E2-1 INV. OUT=4987.79 (S)10.30 LF 12" HDPE @ 3.70% PROPOSED 4' CONCRETE PAN w/ 6" CURBS PROPOSED 10' CONCRETE TRAIL S ELEC S S T S MM W W W W W W W W W W W W FO FO FO FO / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / // / / / / / / // / / / / / / / X X G G G G FO G X FO FO FO FO FO FO X X X X X X X X FO FO FO FO FO FOGGGGGG / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /FO FO FO FO FO G E E E E E E W W W O H U O H U O H U O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU W W W W W W W W W W W W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W S W UGE UGE UGE UGE UGE UGE / / / / / / / / TRACT A DE,UE,AE LOT 5 LOT 4 EXISTING 30' NCWA UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS UTILITY EASEMENT 100' UNION PACIFIC RAILROAD ROW 18' UTILITY EASEMENT PROPOSED 10' CONCRETE TRAIL EXISTING NCWA WATERLINE EXISTING EDGE OF ASPHALT PROPOSED 2' CONCRETE PAN 72' ROW ±41' FL- EOP WILLOX WATER LINE SEE SHEET WT1 291.93 LF 12" HDPE @ 0.50% 35.14 LF 12" HDPE @ 1.20%FES E6 STA 15+26.12 N: 139616.24 E: 192115.23 BASIN E5 STA 14+90.98 N: 139613.79 E: 192080.18 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET ST4 PL A N & P R O F I L E WI L L O X E A S T S T O R M D R A I N 24 WILLOX EAST STORM DRAIN PROFILE SCALE: WILLOX EAST STORM DRAIN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 6.CONCRETE FORBAYS SHALL NOT BE CONSTRUCTED ON RAIN GARDEN BIOMEDIA SOIL. CONTRACTOR SHALL ENSURE FORBAYS ARE CONSTRUCTED ON COMPACTED NATIVE SOIL. PROPOSED RIGHT OF WAY INLET SCHEDULE: ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 NORTH LINE MATCH STA 13+50 LINE MATCH STA 13+50 T T T T XXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX X X X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / UD U DUD SA I N T T H E R E S E S T R E E T SA I N T T H E R E S E S T R E E T SAINT JOSEPH STREET MOLLER STREET SAINT GRACE STREET PROPOSED POND FUTURE CITY OF FORT COLLINS IRRIGATION PIPE (TO BE DESIGNED BY OTHERS) PROPOSED POND OUTFALL WEST WILLOX LANE ACKELSON CONNIE A. KAFKA, AMY PITT, JEAN GBP LLC PEREZ DANIEL A. JENSEN GORDON L. LOT 3LOT 4LOT 5LOT 6 LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 7 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 7 LOT 1 LOT 8 LOT 10 LOT 9 LOT 7 LOT 6 LOT 1 LOT 2 LOT 4 LOT 5 LOT 8 LOT 7 LOT 5 LOT 4 LOT 11 LOT 10 LOT 9 LOT 10 LOT 1LOT 2 LOT 3 BLOCK 3 BLOCK 6 BLOCK 2 TRACT B DE TRACT A DE,UE,AE TRACT D TRACT A DE,UE,AE PROPOSED RAIN GARDEN A BIOMEDIA AREA A3A3 A1A1 A2A2 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 6 LOT 1 LOT 2 LOT 3 LOT 9 LOT 8 LOT 3 LOT 2 LOT 4 LOT 5 LOT 6 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 14 LOT 13 LOT 2 TRACT C DE BLOCK 1 BLOCK 5 EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 20' PRIVATE DRAINAGE EASEMENT TO BE CONVERTED TO PUBLIC EASEMENT EXISTING 10' UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 30' NCWA EASEMENT 100' UNION PACIFIC RAILROAD ROW 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE PROPOSED SIDEWALK CHASES LOT 12 S A I N T J E R O M E S T R E E T SA I N T J E R O M E S T R E E T FUTURE CITY OF FORT COLLINS IRRIGATION PIPE (TO BE DESIGNED BY OTHERS) PROPOSED RAIN GARDEN B BIOMEDIA AREA WILLOX STORM DRAIN SEE SHEET ST3 STORM DRAIN A SEE SHEET ST1 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 RG B UNDERDRAIN SEE SHEET U2 RG A UNDERDRAIN SEE SHEET U2 WILLOX EAST STORM DRAIN SEE SHEET ST4 PROPOSED SIDEWALK CULVERT EMERGENCY OVERFLOW WEIR TESTSTA CONTROL IRR CONTROLIRR CONTROL IRR CONTROL IRR CONTROL IRR X X X X X X X X X C.O. X X X X X X X X X X X X X X X X X X X X X X X X XX / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SOFT GOLD PARK HICKORY STREET CITY OF FORT COLLINS HANSON WILLIAM A/ MERIAM P 40' ROW 20' UTILITY EASEMENT 50' TEMP CONSTRUCTION EASEMENT COFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) WOOD DUCK POND CULVERT SEE SHEET U4 4 - EXISTING 8" STORM PIPES EXISTING 30" STORM DRAIN Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 OG1 OV E R A L L G R A D I N G P L A N 25 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet08080 80 160 240 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK SWALE SECTIONS PROPOSED ASPHALT REPAVING PROPOSED CONCRETE REPAVING SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE THIS SHEET MATCH LINE - SEE THIS SHEET G1 G2 G3 G4 W WWW W T S S M W W T S MM W M XXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / SA I N T T H E R E S E S T R E E T S A I N T J E R O M E S T R E E T MOLLER STREET SAINT JOSEPH STREET ACKELSON CONNIE A. KAFKA, AMY PEREZ DANIEL A. A3A3 A1A1 LOT 7 LOT 5 LOT 4 LOT 6 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 7 LOT 1 TRACT B DE TRACT A DE,UE,AE LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 LOT 8 LOT 3 LOT 2 LOT 4 LOT 5 LOT 6 LOT 9 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 1 LOT 2 LOT 3 LOT 6 TRACT C DE BLOCK 1 BLOCK 5 EXISTING 30' NCWA UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT 0 . 5 % 0 . 5 % PROPOSED 10' CONCRETE TRAIL PROPOSED SIDEWALK CULVERT FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) PROPOSED CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 4' CONCRETE PAN w/ 7" CURBS EXISTING 6' CITY OF FORT COLLINS EASEMENT 57' ROW 57' ROW 30' - 30' - 30' - 100' UNION PACIFIC RAILROAD ROW 72' ROW EXISTING 6' CITY OF FORT COLLINS EASEMENT 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 9' U T I L I T Y E A S E M E N T 9 ' U T I L I T Y E A S E M E N T 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT WEST WILLOX LANE 6 ' U T I L I T Y E A S E M E N T 6 ' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 9 ' U T I L I T Y E A S E M E N T UTILITY EASEMENT (WIDTH VARIES) 15' UTILITY EASEMENT 15' UTILITY EASEMENT 0. 5 % 94.24 94.32 94.09 93.81 93.54 93.2789.01 92.47 92.7488.81 88.67 93.01 93.2988.56 88.48 93.52 93 . 4 4 88.91 92.86 90.17 9 1 . 7 5 9 2 . 7 5 90.48 90.6792.5391.53 91.31 92.31 90.56 90.26 92.04 9 1 . 0 9 90.86 9 0 . 0 5 9 1 . 8 3 90.64 91.62 8 9 . 8 4 89.63 91.38 90.38 90 . 2 1 90.55 90.79 91.02 9 1 . 2 7 92.42 92.15 9 1 . 7 5 9 0 . 6 9 90.71 9 1 . 2 8 91.81 92.47 93 . 7 1 91.72 91.7192.27 92.50 93.50 91.49 91.29 93.7392.73 92.95 93.95 91.17 9 1 . 6 1 9 4 . 1 8 9 3 . 1 8 9 3 . 4 0 9 4 . 4 0 92.51 92.4794.5393.53 9 3 . 4 0 94.40 92.75 92 . 8 5 92.85 92.3 6 92.1 1 91 . 7 2 91 . 4 9 91. 0 7 90.8 4 90. 6 0 90 . 2 0 90 . 4 4 91 . 6 4 91 . 8 7 90 . 6 7 90.8 9 92 . 1 9 92.4 2 91 . 1 2 91.5 1 92 . 8 1 91.7 4 90. 2 9 90.3 5 89. 8 1 0.5% 9 0 . 8 2 91.3 3 91 . 6 8 0. 5 % 0 . 5 % 91.39 91.18 90. 2 5 90. 3 0 90 . 1 5 91.1 0 92.71 9 2 . 7 7 92.4192.84 92.86 92. 4 1 91.6 7 92.41 9 3 . 0 4 9 3 . 0 4 93. 5 2 9 3 . 5 2 92.80 92.81 91.96 92.87 9 2 . 3 7 91. 1 8 91. 3 9 90. 3 2 91. 1 0 89.7 7 87. 4 1 (89.4 6 ) 0 . 9 % 2.3% 1.5% 89 . 5 5 90.1 1 90 . 2 2 90.6 8 90.70 91.26 91 . 3 9 93.80 HP (89 . 9 3 ) 0 . 5 % 0.5% 0.5 % 0 . 5 % 0. 5 % 89 . 3 6 89 . 2 5 89 . 2 0 89.0 9 0 . 5 % 0.5 % 89.00 88.89 88 . 6 9 88 . 4 1 87 . 8 5 87. 6 5 WILLOX STORM DRAIN SEE SHEET ST3 WILLOX EAST STORM DRAIN SEE SHEET ST3 WILLOX EAST STORM DRAIN SEE SHEET ST3 T FG=94.30 TF=94.97 B FG=93.37 TF=94.04 B FG=92.92 TF=93.59 B FG=92.65 TF=93.32 B FG=92.25 TF=92.92 B FG=94.00 TF=94.67 B FG=94.23 TF=94.90 B FG=94.45 TF=95.12 9 2 . 8 7 B FG=94.68 TF=95.35 B FG=94.90 TF=95.57 B FG=95.03 TF=95.70 B FG=95.03 TF=95.70 B FG=94.90 TF=95.57 B FG=93.55 TF=94.22 B FG=93.31 TF=93.98 B FG=92.92 TF=93.59 B FG=92.69 TF=93.36 B FG=92.37 TF=93.04 B FG=92.14 TF=92.81 B FG=92.12 TF=92.79 B FG=92.33 TF=93.00 B FG=92.54 TF=93.21 B FG=92.81 TF=93.48 B FG=93.03 TF=93.70 B FG=93.25 TF=93.92 B FG=93.48 TF=94.15 B FG=94.74 TF=95.41 B FG=94.82 TF=95.49 B FG=94.82 TF=95.49 B FG=94.59 TF=95.26 B FG=94.31 TF=94.98 B FG=94.04 TF=94.71 PROPOSED 4' CONCRETE PAN w/ 7" CURBS PROPOSED 4' CONCRETE PAN w/ 6" CURBS 0. 5 % 0. 5 % 0. 5 % PROPOSED 2' CONCRETE PAN (89 . 2 7 ) 1.5% 1.0% 86.87 (87.7 3 ) STORM DRAIN A SEE SHEET ST1 88.27 (8 7 . 7 9 ) PROPOSED SIDEWALK CULVERT PROPOSED SIDEWALK CULVERT PROPOSED SIDEWALK CHASE 89. 9 6 89. 6 8 93. 0 5 93. 8 5 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 G1 GR A D I N G P L A N 26 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK SWALE SECTIONS PROPOSED ASPHALT REPAVING PROPOSED CONCRETE REPAVING SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 MATCH LINE - SEE SHEET G2 G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R W W T W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX X X X X X X X X X X X UD UD UD U D U D UD UD UD 57' ROW 30' - 57' ROW 30' - SA I N T T H E R E S E S T R E E T SA I N T J E R O M E S T R E E T MOLLER STREET SAINT GRACE STREET PITT, JEAN GBP LLC PEREZ DANIEL A. A2A2 LOT 8 LOT 11 LOT 10 LOT 9 LOT 10 LOT 1LOT 2 LOT 3LOT 4LOT 5 LOT 6 LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 7 LOT 3 LOT 8 LOT 10 LOT 9 LOT 7 LOT 6 LOT 1 LOT 2 LOT 4 LOT 5 TRACT A DE,UE,AE TRACT D BLOCK 6 LOT 14 LOT 13 LOT 12 0. 5 % 0. 5 % PROPOSED 2' SIDEWALK CHASE PROPOSED SIDEWALK CULVERT PROPOSED RAIN GARDEN UNDER DRAIN PROPOSED 10' CONCRETE TRAIL PROPOSED 10' CONCRETE TRAIL PROPOSED POND OUTLET STRUCTURE FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (TO BE DESIGNED BY OTHERS) PROPOSED 2' CONCRETE PAN EXISTING 20' DRAINAGE EASEMENT EXISTING 10' UTILITY EASEMENT 57' ROW 57' ROW 30' - 30' - 57' ROW 30' - 30' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 20' IRRIGATION EASEMENT FOR FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE 9' UTILITY EASEMENT 9' UTILITY EASEMENT 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK PROPOSED DETENTION POND 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 6' UTILITY EASEMENT 6' U T I L I T Y E A S E M E N T 6' U T I L I T Y E A S E M E N T 15' UTILITY EASEMENT15' UTILITY EASEMENT DOG PARK 5' S I D E W A L K PROPOSED FOREBAY PROPOSED FOREBAY PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED STORM DRAIN 30' DRAINAGE EASEMENT 91.69 92.0792.3592.60 92.87 93.05 93.21 93. 3 8 93.76 94.17 94.34 94.21 93.56 90.69 92.76 93.41 89.67 89.19 93.54 93.37 90 . 1 8 89.66 92.96 92.86 92 . 5 8 92. 4 1 89. 5 2 89.43 89.33 9 2 . 2 5 92. 0 7 9 2 . 1 8 9 2 . 1 0 92. 0 3 91.88 91.35 90.99 90.89 88.27 88.2788.8089.05 89.30 91.80 91.55 88.27 90.19 90.63 90.74 9 0 . 5 3 88. 2 6 9 0 . 9 8 91.97 88. 7 6 8 8 . 9 1 92.23 91.30 9 1 . 5 8 9 2 . 5 8 89.52 91.8 0 92.80 89.71 89.9093.0392.03 92.13 9 3 . 0 0 90.09 90.2892.9891.98 92 . 1 3 92 . 0 4 93 . 3 4 92.4 4 92.38 92 . 4 6 93.1 8 91 . 8 1 9 2 . 2 0 92 . 9 9 91.5 9 91 . 3 3 92 . 7 3 91 . 9 5 92.4 4 91 . 6 9 91 . 0 8 91.02 92 . 3 5 92.82 9 2 . 8 5 9 1 . 8 4 9 2 . 0 7 92 . 2 9 9 4 . 2 5 9 3 . 4 5 9 3 . 1 9 9 3 . 5 4 9 4 . 3 4 92.52 92.7494.1793.37 9 2 . 8 0 93.56 9 2 . 9 7 9 1 . 9 7 91.27 9 2 . 2 5 H P 0. 5 % 91.27 91.07 91.43 92.37 92 . 8 1 92.1 9 91.06 93.29 88.17 85 . 7 4 86.24 0 . 5 % 0.5% 85.89 86.39 8 4 . 8 9 84. 8 9 8 4 . 9 9 82. 9 6 0. 5 % 8 5 . 0 7 85.28 86.82 8 7 . 2 2 8 6 . 9 0 86.38 86.53 87.32 8 5 . 2 4 84.84 82. 8 9 STORM DRAIN A SEE SHEET ST1 STORM DRAIN C SEE SHEET ST2 STORM DRAIN B SEE SHEET ST2 B FG=93.50 TF=94.17 B FG=93.50 TF=94.17 B FG=93.53 TF=94.20 B FG=93.30 TF=93.97 B FG=93.08 TF=93.75 B FG=92.73 TF=93.40 B FG=92.47 TF=93.14 B FG=92.19 TF=92.86 B FG=92.57 TF=93.24 B FG=92.85 TF=93.52 B FG=93.10 TF=93.77 B FG=93.37 TF=94.04 B FG=93.55 TF=94.22 B FG=93.71 TF=94.38 B FG=93.88 TF=94.55 B FG=94.26 TF=94.93 B FG=94.67 TF=95.34 B FG=94.84 TF=95.51 B FG=94.84 TF=95.51 B FG=94.71 TF=95.38 B FG=94.67 TF=95.34 B FG=94.84 TF=95.51 B FG=94.84 TF=95.51 B FG=94.75 TF=95.42 B FG=94.49 TF=95.16 B FG=93.23 TF=93.90 B FG=93.49 TF=94.16 B FG=93.68 TF=94.35 B FG=93.84 TF=94.51 B FG=93.86 TF=94.53 93.36 PROPOSED 4' CONCRETE PAN w/ 6" CURBS PROPOSED RAIN GARDEN A BIOMEDIA AREA PROPOSED RAIN GARDEN B BIOMEDIA AREA EMERGENCY OVERFLOW WEIR PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN 9 0 . 0 0 89.62 8 8 . 9 0 8 9 . 9 7 88.41 84.74 87.25 8 3 . 3 5 85.74 83.67 87.28 87 . 2 0 86.20 8 6 . 2 0 8 6 . 2 0 87.2 0 8 2 . 9 9 85.31 84.58 84.74 8 4 . 7 4 8 6 . 2 4 85.16 8 5 . 2 6 8 5 . 0 2 8 5 . 5 6 84.9 1 8 5 . 9 2 86.39 84.81 84.74 87.52 88.19 8 6 . 7 6 PROPOSED LANDSCAPE WALL PROPOSED LANDSCAPE WALL 84 . 9 1 84 . 8 9 84 . 9 1 85. 0 2 85. 2 3 86 . 0 8 0.5%0.5% 0.5 % 87 . 2 8 87.20 85.98 85. 1 9 84.50 83.64 85.80 86.39 86.04 85.99 94.00 (82.67) Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 G2 GR A D I N G P L A N 27 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK SWALE SECTIONS PROPOSED ASPHALT REPAVING PROPOSED CONCRETE REPAVING SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 MATCH LINE - SEE SHEET G3 MATCH LINE - SEE SHEET G1 G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X JE N S E N G O R D O N L . CITY OF FORT COLLINS PEREZ DANIEL A. 133' OF PROPOSED DOG PARK FENCE PROPOSED 10' CONCRETE TRAIL 50' NHBZ 40' UTILITY EASEMENT PROPOSED 12' CONCRETE TRAIL SOFT GOLD PARK CITY OF FORT COLLINS IRRIGATION POND PROPOSED 12' CONCRETE TRAIL PROPOSED CONCRETE TRAIL (WIDTH VARIES) 84.18 83 . 8 0 (84 . 3 3 ) 83.85 82.78 81.88 80.17 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 G3 GR A D I N G P L A N 28 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK SWALE SECTIONS PROPOSED ASPHALT REPAVING PROPOSED CONCRETE REPAVING SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 MATCH LINE - SEE SHEET G4 MATCH LINE - SEE SHEET G2 G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TESTSTA X X X B M X X X X X X X X X X X X X X X X X X X XX XXXX / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CITY OF FORT COLLINS CITY OF FORT COLLINS PEREZ DANIEL A. HANSON WILLIAM A/ MERIAM P PROPOSED 12' CONCRETE TRAIL 40' ROW EXISTING 20' UTILITY EASEMENT EXISTING 50' TEMP CONSTRUCTION EASEMENT COFC CATHODIC PROTECTION PROJECT EASEMENT (WIDTH VARIES) UTILITY EASEMENT (WIDTH VARIES) HICKORY STREET BASKETBALL COURTS EXISTING PLAYGROUND BASEBALL DIAMOND SOFT GOLD PARK WOOD DUCK POND REMOVABLE BOLLARDS CULVERT SEE SHEET U3 EXISTING 30" STORM DRAIN EXISTING 4-8" PVC STORM DRAIN B80.37 B 8 0 . 2 6 B (78.93) B (7 8 . 7 6 ) B81.00 B(77.73) B(78.37) B(79.27) B(80.02) B (79 . 3 6 ) B(78.16) B(78.56) Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 G4 GR A D I N G P L A N 29 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK SWALE SECTIONS PROPOSED ASPHALT REPAVING PROPOSED CONCRETE REPAVING SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 MATCH LINE - SEE SHEET G3 G1 G2 G3 G4 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R X X X X X X X X X W W W W W SAINT THERESE STREET 30' FL-FL 5 ' SIDEWALK 5 ' SIDEWALK 5 ' SIDEWALK SAINT JOSEPH STREET (SEE SHEET R4) WEST WILLOX LANE (SEE SHEET R7-R10) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT TRACT B TRACT A DE,UE,AE LOT 3LOT 4LOT 5 LOT 7 LOT 6 PROPOSED 10' CONCRETE PAN PROPOSED DRIVEOVER CURB & GUTTER 57' ROW STA. = 12+40.94 (SAINT THERESE ST) STA. = 10+00.00 (SAINT JOSEPH STREET) R25'R25' LOT 1 LOT 8 LOT 4LOT 5LOT 6 LOT 2 BLOCK 1 BLOCK 5 LOT 3 TRACT B DE 10' CROSS PAN STA. = 10+00.00 (SAINT THERESE ST) STA. = 21+58.53 (WEST WILLOX LANE) STOP SIGN STOP SIGN 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 2 . 4 7 49 9 3 . 0 1 49 9 2 . 4 5 49 9 2 . 0 5 49 9 2 . 6 4 49 9 1 . 9 1 49 9 2 . 2 6 49 9 2 . 7 3 49 9 3 . 1 2 49 9 3 . 0 5 49 9 2 . 8 2 49 9 2 . 0 4 49 9 1 . 5 7 49 9 1 . 6 8 49 9 2 . 2 6 49 9 2 . 3 9 49 9 2 . 5 1 49 9 2 . 7 6 49 9 2 . 8 9 49 9 3 . 0 1 -2.21%2.00% -1.50%0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 2 . 4 7 PV I S T A = 1 0 + 2 9 . 0 0 PV I E L E V = 4 9 9 1 . 7 7 PV I S T A = 1 2 + 5 9 . 6 9 PV I E L E V = 4 9 9 1 . 3 7 50.0' VC PVI STA = 10+84.00 PVI ELEV = 4992.94 BV C S : 1 0 + 5 9 BV C E : 4 9 9 2 . 4 4 EV C S : 1 1 + 0 9 EV C E : 4 9 9 3 . 0 7 A.D. = 1.50 K = 33.33 60.0' VC PVI STA = 12+24.69 PVI ELEV = 4992.08 BV C S : 1 1 + 9 4 . 6 9 BV C E : 4 9 9 2 . 5 3 EV C S : 1 2 + 5 4 . 6 9 EV C E : 4 9 9 1 . 4 8 A.D. = 0.52 K = 116.27 60.0' VC PVI STA = 12+94.69 PVI ELEV = 4992.11 BV C S : 1 2 + 6 4 . 6 9 BV C E : 4 9 9 1 . 4 8 EV C S : 1 3 + 2 4 . 6 9 EV C E : 4 9 9 2 . 2 6 A.D. = 1.60 K = 37.51 75.0' VC HP ELEV = 4993.12 HP STA = 11+27.75 PVI STA = 11+46.50 PVI ELEV = 4993.26 BV C S : 1 1 + 0 9 BV C E : 4 9 9 3 . 0 7 EV C S : 1 1 + 8 4 EV C E : 4 9 9 2 . 6 9 A.D. = 2.00 K = 37.50 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 2 . 0 5 49 9 2 . 3 1 49 9 2 . 5 6 49 9 2 . 7 0 49 9 2 . 6 3 49 9 2 . 4 0 49 9 2 . 0 4 49 9 1 . 7 1 49 9 1 . 3 9 49 9 1 . 4 4 49 9 1 . 7 2 49 9 1 . 8 4 49 9 1 . 9 7 49 9 2 . 0 9 49 9 2 . 2 2 49 9 2 . 3 5 49 9 2 . 4 7 49 9 2 . 6 0 PROPOSED GRADE EXISTING GROUND -1.50% -1.25%0.50%0.50%0.50% 1.67% 1.50% 1.00% 1.00% 0.50% PV I S T A = 1 0 + 2 9 . 0 1 PV I E L E V = 4 9 9 1 . 7 0 PV I S T A = 1 2 + 0 6 . 7 0 PV I E L E V = 4 9 9 1 . 9 4 PV I S T A = 1 2 + 5 9 . 7 9 PV I E L E V = 4 9 9 1 . 2 2 PV I S T A = 1 3 + 2 4 . 6 9 PV I E L E V = 4 9 9 1 . 8 4 PV I S T A = 1 4 + 3 7 . 1 2 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 0 + 5 1 . 0 3 PV I E L E V = 4 9 9 2 . 0 7 PV I S T A = 1 2 + 8 0 . 9 7 PV I E L E V = 4 9 9 1 . 5 3 PV I S T A = 1 1 + 0 9 . 0 5 PV I E L E V = 4 9 9 2 . 6 5 PV I S T A = 1 2 + 9 8 . 8 8 PV I E L E V = 4 9 9 1 . 7 1 PV I S T A = 1 3 + 1 0 . 9 6 PV I E L E V = 4 9 9 1 . 7 7 75.0' VC HP ELEV = 4992.70 HP STA = 11+27.78 PVI STA = 11+46.55 PVI ELEV = 4992.84 BV C S : 1 1 + 0 9 . 0 5 BV C E : 4 9 9 2 . 6 5 EV C S : 1 1 + 8 4 . 0 5 EV C E : 4 9 9 2 . 2 8 A.D. = 2.00 K = 37.47 PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 2 . 0 6 49 9 2 . 3 1 49 9 2 . 5 6 49 9 2 . 7 0 49 9 2 . 6 3 49 9 2 . 4 0 49 9 2 . 0 6 49 9 1 . 8 1 49 9 1 . 5 6 49 9 1 . 5 9 49 9 1 . 7 2 49 9 1 . 8 4 49 9 1 . 9 7 49 9 2 . 0 9 49 9 2 . 2 1 49 9 2 . 3 4 49 9 2 . 4 6 49 9 2 . 5 9 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 1.00%-0.50%0.50% 0.50%1.00%-1.50%-1.00% 0.50% PV I S T A = 1 0 + 2 9 . 0 1 PV I E L E V = 4 9 9 1 . 8 5 PV I S T A = 1 0 + 5 0 . 9 9 PV I E L E V = 4 9 9 2 . 0 7 PV I S T A = 1 1 + 0 9 . 0 2 PV I E L E V = 4 9 9 2 . 6 5 PV I S T A = 1 1 + 9 4 . 8 0 PV I E L E V = 4 9 9 2 . 1 1 PV I S T A = 1 2 + 4 9 . 6 6 PV I E L E V = 4 9 9 1 . 5 7 PV I S T A = 1 2 + 5 9 . 7 9 PV I E L E V = 4 9 9 1 . 5 2 PV I S T A = 1 3 + 2 4 . 8 9 PV I E L E V = 4 9 9 1 . 8 4 PV I S T A = 1 4 + 3 8 . 6 7 PV I E L E V = 4 9 9 2 . 4 1 75.0' VC HP ELEV = 4992.70 HP STA = 11+27.77 PVI STA = 11+46.52 PVI ELEV = 4992.84 BV C S : 1 1 + 0 9 . 0 2 BV C E : 4 9 9 2 . 6 5 EV C S : 1 1 + 8 4 . 0 2 EV C E : 4 9 9 2 . 2 8 A.D. = 2.00 K = 37.50 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R1 PL A N & P R O F I L E SA I N T T H E R E S E S T R E E T 30 NORTH CENTERLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT L I N E M A T C H S T A 15 + 0 0 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R1 R2 ST A MA T C H L I N E SE E S H E E T 15 + 0 0 R2 SAINT THERESE STREET STA. = 16+92.28 (SAINT THERESE ST) STA. = 11+59.16 (MOLLER STREET) 30' FL-FL 57' ROW57' ROW 30' FL-FL 5 ' SIDEWALK 5 ' SIDEWALK 5 ' SIDEWALK 5 ' SIDEWALK MOLLER STREET (SEE SHEET R6) SAINT GRACE STREET (SEE SHEET R3) STA. = 19+01.98 (SAINT THERESE ST) STA. = 10+00.00 (SAINT GRACE STREET) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 1LOT 2LOT 3 LOT 1 LOT 10LOT 12 LOT 11 LOT 8 LOT 13 LOT 9 LOT 3 LOT 1LOT 2 LOT 4LOT 5 BLOCK 4 BLOCK 5 BLOCK 3 BLOCK 6 PROPOSED DRIVEOVER CURB & GUTTER LOT 4 LOT 3 LOT 2 R25'R25' R25'R25' 6' CONCRETE PAN STOP SIGN STOP SIGN 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 15+00 16+00 17+00 18+00 19+00 20+00 20+50 49 9 3 . 1 8 49 9 2 . 2 1 49 9 3 . 2 6 49 9 3 . 0 8 49 9 3 . 2 6 49 9 3 . 3 1 49 9 3 . 2 9 49 9 2 . 9 4 49 9 2 . 5 2 49 9 1 . 9 8 49 9 2 . 3 2 49 9 2 . 8 0 49 9 3 . 1 1 49 9 3 . 3 2 49 9 3 . 3 1 49 9 3 . 2 1 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 2.20%-2.20%-2.00%2.00% 0.50%-0.50%-0.50%0.50% PV I S T A = 1 6 + 9 2 . 4 6 PV I E L E V = 4 9 9 2 . 3 7 PV I S T A = 1 6 + 7 5 . 6 3 PV I E L E V = 4 9 9 1 . 9 5 PV I S T A = 1 7 + 0 9 . 3 0 PV I E L E V = 4 9 9 1 . 9 5 PV I S T A = 1 9 + 0 1 . 9 8 PV I E L E V = 4 9 9 3 . 0 7 50.0' VC PVI STA = 16+22.63 PVI ELEV = 4993.07 BV C S : 1 5 + 9 7 . 6 3 BV C E : 4 9 9 3 . 1 9 EV C S : 1 6 + 4 7 . 6 3 EV C E : 4 9 9 2 . 5 7 A.D. = 1.50 K = 33.33 50.0' VC PVI STA = 17+62.30 PVI ELEV = 4993.07 BV C S : 1 7 + 3 7 . 3 0 BV C E : 4 9 9 2 . 5 7 EV C S : 1 7 + 8 7 . 3 0 EV C E : 4 9 9 3 . 1 9 A.D. = 1.50 K = 33.33 75.0' VC HP ELEV = 4993.33 HP STA = 18+32.62 PVI STA = 18+32.62 PVI ELEV = 4993.42 BV C S : 1 7 + 9 5 . 1 2 BV C E : 4 9 9 3 . 2 3 EV C S : 1 8 + 7 0 . 1 2 EV C E : 4 9 9 3 . 2 3 A.D. = 1.00 K = 75.00 75.0' VC HP ELEV = 4993.32 HP STA = 15+54.57 PVI STA = 15+54.57 PVI ELEV = 4993.41 BV C S : 1 5 + 1 7 . 0 7 BV C E : 4 9 9 3 . 2 2 EV C S : 1 5 + 9 2 . 0 7 EV C E : 4 9 9 3 . 2 2 A.D. = 1.00 K = 75.00 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 15+00 16+00 17+00 18+00 19+00 19+50 49 9 3 . 1 8 49 9 2 . 2 1 49 9 3 . 2 6 49 9 3 . 0 8 49 9 3 . 2 6 49 9 3 . 3 1 49 9 3 . 2 9 49 9 2 . 9 4 49 9 2 . 5 2 49 9 1 . 9 8 49 9 2 . 3 2 49 9 2 . 8 0 49 9 3 . 1 1 49 9 3 . 3 2 49 9 3 . 3 1 49 9 3 . 2 1 PROPOSED GRADE EXISTING GROUND 2.20%-2.20%-2.00%2.00% 0.50%-0.50%-0.50%0.50% PV I S T A = 1 6 + 9 2 . 4 6 PV I E L E V = 4 9 9 2 . 3 7 PV I S T A = 1 6 + 7 5 . 6 3 PV I E L E V = 4 9 9 1 . 9 5 PV I S T A = 1 7 + 0 9 . 3 0 PV I E L E V = 4 9 9 1 . 9 5 PV I S T A = 1 9 + 0 1 . 9 8 PV I E L E V = 4 9 9 3 . 0 7 50.0' VC PVI STA = 16+22.63 PVI ELEV = 4993.07 BV C S : 1 5 + 9 7 . 6 3 BV C E : 4 9 9 3 . 1 9 EV C S : 1 6 + 4 7 . 6 3 EV C E : 4 9 9 2 . 5 7 A.D. = 1.50 K = 33.33 50.0' VC PVI STA = 17+62.30 PVI ELEV = 4993.07 BV C S : 1 7 + 3 7 . 3 0 BV C E : 4 9 9 2 . 5 7 EV C S : 1 7 + 8 7 . 3 0 EV C E : 4 9 9 3 . 1 9 A.D. = 1.50 K = 33.33 75.0' VC HP ELEV = 4993.33 HP STA = 18+32.62 PVI STA = 18+32.62 PVI ELEV = 4993.42 BV C S : 1 7 + 9 5 . 1 2 BV C E : 4 9 9 3 . 2 3 EV C S : 1 8 + 7 0 . 1 2 EV C E : 4 9 9 3 . 2 3 A.D. = 1.00 K = 75.00 75.0' VC HP ELEV = 4993.32 HP STA = 15+54.57 PVI STA = 15+54.57 PVI ELEV = 4993.41 BV C S : 1 5 + 1 7 . 0 7 BV C E : 4 9 9 3 . 2 2 EV C S : 1 5 + 9 2 . 0 7 EV C E : 4 9 9 3 . 2 2 A.D. = 1.00 K = 75.00 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 15+00 16+00 17+00 18+00 19+00 19+50 49 8 8 . 1 7 49 8 7 . 8 0 49 8 7 . 6 0 49 8 7 . 4 5 49 8 7 . 2 1 49 8 7 . 0 4 49 8 7 . 1 1 49 8 6 . 6 5 49 8 6 . 5 4 49 8 6 . 4 5 49 8 6 . 4 2 49 8 6 . 3 0 49 8 6 . 3 7 49 8 6 . 6 3 49 8 6 . 4 0 49 8 6 . 3 8 1.49% 1.00%0.50%-0.50% -2.20%2.20%-1.52% -0.50%-1.00%0.50% PV I S T A = 1 7 + 3 2 . 5 6 PV I E L E V = 4 9 9 2 . 2 3 PV I S T A = 1 7 + 8 7 . 4 2 PV I E L E V = 4 9 9 2 . 7 7 PV I S T A = 1 9 + 0 2 . 0 8 PV I E L E V = 4 9 9 2 . 6 5 PV I S T A = 1 7 + 0 9 . 4 0 PV I E L E V = 4 9 9 1 . 8 8 PV I S T A = 1 6 + 9 2 . 5 6 PV I E L E V = 4 9 9 2 . 3 0 PV I S T A = 1 6 + 7 5 . 7 3 PV I E L E V = 4 9 9 1 . 8 8 PV I S T A = 1 5 + 9 8 . 0 6 PV I E L E V = 4 9 9 2 . 7 7 PV I S T A = 1 6 + 5 2 . 5 6 PV I E L E V = 4 9 9 2 . 2 3 74.7' VC HP ELEV = 4992.90 HP STA = 15+55.17 PVI STA = 15+55.26 PVI ELEV = 4992.99 BV C S : 1 5 + 1 7 . 9 2 BV C E : 4 9 9 2 . 8 0 EV C S : 1 5 + 9 2 . 6 0 EV C E : 4 9 9 2 . 8 0 A.D. = 1.00 K = 74.43 75.0' VC HP ELEV = 4992.91 HP STA = 18+32.72 PVI STA = 18+32.72 PVI ELEV = 4993.00 BV C S : 1 7 + 9 5 . 2 2 BV C E : 4 9 9 2 . 8 1 EV C S : 1 8 + 7 0 . 2 2 EV C E : 4 9 9 2 . 8 1 A.D. = 1.00 K = 75.00 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R2 PL A N & P R O F I L E SA I N T T H E R E S E S T R E E T 31 NORTH CENTERLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE SAINT THERESE STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT L I N E M A T C H S T A 15 + 0 0 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R1 R2 ST A MA T C H L I N E SE E S H E E T 15 + 0 0 R1 U D UD STA. = 10+00.00 (SAINT GRACE STREET) STA. = 19+01.98 (SAINT THERESE ST) 30' - 57' ROW 5' SIDEWALK 5' SIDEWALK PROPOSED 4' SIDEWALK CULVERT 15' UTILITY EASEMENT 9' UTILITY EASEMENT SAINT GRACE STREET SAINT THERESE STREET (SEE SHEET R2) SAINT JEROME STREET (SEE SHEET R5) PROPOSED 10' CONCRETE PAN PROPOSED SIDEWALK CHASE LOT 10 LOT 9 LOT 1 LOT 2LOT 10 LOT 1 LOT 2LOT 3LOT 4 LOT 5LOT 6 LOT 8 LOT 9 LOT 7 BLOCK 6 BLOCK 3 TRACT A DE,UE,AE TRACT D PROPOSED DRIVEOVER CURB & GUTTER STA. = 14+81.90 (SAINT GRACE STREET) STA. = 18+74.87 (SAINT JEROME STREET) REMOVABLE BOLLARDS LOT 14 LOT 13 LOT 12 BLOCK 2 R25' R25' 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50 49 9 3 . 0 7 49 9 2 . 8 9 49 9 2 . 7 0 49 9 2 . 5 1 49 9 2 . 3 2 49 9 2 . 1 4 49 9 1 . 9 5 49 9 1 . 7 6 49 9 1 . 6 0 49 9 1 . 4 8 49 9 1 . 3 5 49 9 1 . 2 3 49 9 1 . 0 9 49 9 0 . 8 8 49 9 0 . 6 1 49 9 0 . 3 0 49 9 0 . 4 4 49 9 0 . 7 3 49 9 0 . 9 7 49 9 1 . 1 6 -0.75% -0.50%-0.75%0.75% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 3 . 0 7 PV I S T A = 1 1 + 8 7 . 8 0 PV I E L E V = 4 9 9 1 . 6 7 PV I S T A = 1 2 + 9 4 . 0 2 PV I E L E V = 4 9 9 1 . 1 3 PV I S T A = 1 3 + 8 2 . 1 5 PV I E L E V = 4 9 9 0 . 1 5 PV I S T A = 1 4 + 8 1 . 9 0 PV I E L E V = 4 9 9 1 . 2 1 75.0' VC PVI STA = 13+39.65 PVI ELEV = 4990.79 BV C S : 1 3 + 0 2 . 1 5 BV C E : 4 9 9 1 . 0 7 EV C S : 1 3 + 7 7 . 1 5 EV C E : 4 9 9 0 . 2 7 A.D. = 0.65 K = 115.35 75.0' VC PVI STA = 14+24.65 PVI ELEV = 4990.78 BV C S : 1 3 + 8 7 . 1 5 BV C E : 4 9 9 0 . 2 7 EV C S : 1 4 + 6 2 . 1 5 EV C E : 4 9 9 1 . 0 6 A.D. = 0.63 K = 119.85 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 49 9 2 . 6 5 49 9 2 . 4 7 49 9 2 . 2 8 49 9 2 . 0 4 49 9 1 . 7 4 49 9 1 . 5 4 49 9 1 . 3 5 49 9 1 . 1 9 49 9 1 . 0 7 49 9 0 . 9 4 49 9 0 . 8 2 49 9 0 . 6 8 49 9 0 . 5 5 49 9 0 . 4 2 49 9 0 . 3 1 49 9 0 . 4 3 49 9 0 . 5 6 49 9 0 . 7 2 -0.75% -1.20% 0.50%0.50% -0.75% -0.50% -0.50%-0.75%0.60%0.75% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 2 . 6 5 PV I S T A = 1 0 + 6 2 . 4 8 PV I E L E V = 4 9 9 2 . 1 9 PV I S T A = 1 1 + 0 1 . 7 5 PV I E L E V = 4 9 9 1 . 7 2 PV I S T A = 1 3 + 7 2 . 2 8 PV I E L E V = 4 9 9 0 . 4 2 PV I S T A = 1 4 + 0 2 . 2 8 PV I E L E V = 4 9 9 0 . 5 7 PV I S T A = 1 1 + 6 4 . 2 3 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 3 + 4 9 . 0 0 PV I E L E V = 4 9 9 0 . 3 0 PV I S T A = 1 2 + 7 0 . 4 4 PV I E L E V = 4 9 9 0 . 7 2 PV I S T A = 1 2 + 7 8 . 5 7 PV I E L E V = 4 9 9 0 . 6 5 PV I S T A = 1 4 + 1 5 . 0 3 PV I E L E V = 4 9 9 0 . 6 5 PV I S T A = 1 4 + 3 4 . 7 8 PV I E L E V = 4 9 9 0 . 7 9 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 49 9 2 . 6 5 49 9 2 . 4 0 49 9 2 . 1 5 49 9 2 . 0 0 49 9 1 . 8 7 49 9 1 . 7 5 49 9 1 . 6 2 49 9 1 . 5 0 49 9 1 . 3 7 49 9 1 . 2 5 49 9 1 . 1 2 49 9 1 . 0 0 49 9 0 . 8 7 49 9 0 . 7 5 49 9 0 . 5 6 49 9 0 . 3 3 49 9 0 . 1 1 49 8 9 . 9 7 49 9 0 . 0 0 49 9 0 . 1 2 49 9 0 . 2 9 49 9 0 . 5 1 49 9 0 . 7 3 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -0.50% -1.00% -0.50% 0.85% 0.50%0.90%-0.50% -0.80%-0.90% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 2 . 6 5 PV I S T A = 1 0 + 5 6 . 4 1 PV I E L E V = 4 9 9 2 . 0 9 PV I S T A = 1 2 + 2 5 . 2 9 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 3 + 3 1 . 5 1 PV I E L E V = 4 9 9 0 . 7 2 PV I S T A = 1 3 + 3 9 . 6 2 PV I E L E V = 4 9 9 0 . 6 5 PV I S T A = 1 4 + 0 2 . 4 3 PV I E L E V = 4 9 9 0 . 0 8 PV I S T A = 1 4 + 3 5 . 0 2 PV I E L E V = 4 9 8 9 . 9 2 PV I S T A = 1 4 + 8 9 . 2 7 PV I E L E V = 4 9 9 0 . 1 9 PV I S T A = 1 5 + 4 3 . 7 0 PV I E L E V = 4 9 9 0 . 6 8 PV I S T A = 1 5 + 5 6 . 8 9 PV I E L E V = 4 9 9 0 . 7 9 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R3 PL A N & P R O F I L E SA I N T G R A C E S T R E E T 32 NORTH CENTERLINE SAINT GRACE STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE SAINT GRACE STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE SAINT GRACE STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R3 X E E E E E E 5' SIDEW A L K 5' SIDEW A L K 5' S I D E W A L K 5 ' S I D E W A L K TRACT A DE,UE,AE STA. = 10+00.00 (SAINT JOSEPH STREET) STA. = 12+40.94 (SAINT THERESE STREET) LOT 6 PROPOSED DRIVEOVER CURB & GUTTER SAINT T H E R E S E S T R E E T (SEE S H E E T R1 ) LOT 4 BLOCK 1 LOT 1 LOT 5 LOT 8 LOT 7 LOT 9 LOT 1 LOT 2 TRACT C DE UTILITY E A S E M E N T (WIDTH V A R I E S ) 9' UTILIT Y E A S E M E N T R25' R25' SAINT J O S E P H S T R E E T PROPOSED 10' CROSSPAN PROPOSED 2' SIDEWALK CHASE PROPOSED 2' SIDEWALK CULVERT 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 49 9 0 . 9 7 49 9 0 . 4 2 49 9 1 . 6 2 49 9 1 . 4 0 49 9 1 . 1 7 49 9 0 . 8 4 49 9 0 . 7 0 49 9 0 . 5 6 49 9 0 . 2 8 49 9 0 . 1 0 49 8 9 . 8 5 49 8 9 . 8 2 49 9 0 . 1 0 49 9 0 . 2 9 -2.20% -0.90% -0.55% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 2 . 0 3 PV I S T A = 1 0 + 1 3 . 8 3 PV I E L E V = 4 9 9 1 . 7 2 PV I S T A = 1 0 + 9 2 . 9 2 PV I E L E V = 4 9 9 1 . 0 1 PV I S T A = 1 3 + 0 1 . 6 7 PV I E L E V = 4 9 8 9 . 4 4 75.0' VC PVI STA = 12+59.08 PVI ELEV = 4990.10 BV C S : 1 2 + 2 1 . 5 8 BV C E : 4 9 9 0 . 3 0 EV C S : 1 2 + 9 6 . 5 8 EV C E : 4 9 8 9 . 5 8 A.D. = 0.84 K = 89.48 75.1' VC PVI STA = 13+44.18 PVI ELEV = 4990.14 BV C S : 1 3 + 0 6 . 6 5 BV C E : 4 9 8 9 . 5 6 EV C S : 1 3 + 8 1 . 7 1 EV C E : 4 9 9 0 . 3 2 A.D. = 1.03 K = 72.67 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 49 9 1 . 0 1 49 9 0 . 7 6 49 9 0 . 6 0 49 9 0 . 4 5 49 9 0 . 3 0 49 9 0 . 1 5 49 9 0 . 0 0 49 8 9 . 8 5 49 8 9 . 7 1 49 8 9 . 5 9 49 8 9 . 4 6 49 8 9 . 4 0 49 8 9 . 5 3 49 8 9 . 6 5 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -1.00% -0.60% -0.50%0.50% PV I S T A = 1 0 + 4 0 . 0 3 PV I E L E V = 4 9 9 1 . 1 0 PV I S T A = 1 0 + 7 5 . 0 6 PV I E L E V = 4 9 9 0 . 7 5 PV I S T A = 1 2 + 4 2 . 4 1 PV I E L E V = 4 9 8 9 . 7 5 PV I S T A = 1 3 + 1 8 . 5 1 PV I E L E V = 4 9 8 9 . 3 7 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 49 9 0 . 9 8 49 9 0 . 7 5 49 9 0 . 5 8 49 9 0 . 4 1 49 9 0 . 2 6 49 9 0 . 1 1 49 8 9 . 9 6 49 8 9 . 8 2 49 8 9 . 6 9 49 8 9 . 5 7 49 8 9 . 6 0 49 8 9 . 7 2 49 8 9 . 8 5 49 8 9 . 9 7 -0.90%-0.70% -0.60% -0.50%0.50%0.50% PV I S T A = 1 0 + 4 0 . 0 3 PV I E L E V = 4 9 9 1 . 0 7 PV I S T A = 1 0 + 7 5 . 0 0 PV I E L E V = 4 9 9 0 . 7 5 PV I S T A = 1 1 + 1 6 . 9 3 PV I E L E V = 4 9 9 0 . 4 6 PV I S T A = 1 2 + 1 8 . 4 0 PV I E L E V = 4 9 8 9 . 8 5 PV I S T A = 1 2 + 8 4 . 8 5 PV I E L E V = 4 9 8 9 . 5 2 PV I S T A = 1 3 + 6 1 . 6 4 PV I E L E V = 4 9 8 9 . 9 0 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R4 PL A N & P R O F I L E SA I N T J O S E P H S T R E E T 33 NORTH CENTERLINE SAINT JOSEPH STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE SAINT JOSEPH STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE SAINT JOSEPH STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT ST A MA T C H L I N E SE E S H E E T 14 + 0 0 R5 LINE MAT C H STA 14+0 0 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R4 R5 UD 30' - 57' ROW 30' - 57' ROW 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK5' SIDEWALK 5' SIDEW A L K 5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILIT Y E A S E M E N T 9' UTILIT Y E A S E M E N T PROPOSED 10' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED 6' CONCRETE PAN LOT 7 LOT 5 LOT 4 LOT 11LOT 10LOT 9 LOT 1 LOT 3 LOT 8 LOT 10LOT 9LOT 7LOT 6 BLOCK 2 BLOCK 6 TRACT A DE,UE,AE PROPOSED DRIVEOVER CURB & GUTTER PROPOSED DRIVEOVER CURB & GUTTER STA. = 18+74.87 (SAINT JEROME STREET) STA. = 14+81.90 (SAINT GRACE STREET) LOT 8 LOT 2 SAINT JEROME STREETSAINT JE R O M E S T R E E T MOLLER STREET (SEE SHEET R6) SAINT GRACE STREET (SEE SHEET R3) LOT 9 LOT 14 LOT 13 LOT 12 LOT 11 LOT 10 LOT 1 LOT 2 LOT 3 LOT 6 LOT 14LOT 13LOT 12 R25'R25' R25' STA. = 16+65.36 (SAINT JEROME STREET) STA. = 14+70.43 (MOLLER STREET) 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 14+00 15+00 16+00 17+00 18+00 19+00 19+50 PROPOSED GRADE EXISTING GROUND 49 9 0 . 9 1 49 9 1 . 4 3 49 9 1 . 9 0 49 9 1 . 5 9 49 9 0 . 5 4 49 9 0 . 6 6 49 9 0 . 7 9 49 9 1 . 0 5 49 9 1 . 1 8 49 9 1 . 3 1 49 9 1 . 5 6 49 9 1 . 6 8 49 9 1 . 8 1 49 9 1 . 9 1 49 9 1 . 8 4 49 9 1 . 7 1 49 9 1 . 4 6 49 9 1 . 3 4 0.55%0.50%-0.50% 0.50% PV I S T A = 1 5 + 1 0 . 3 3 PV I E L E V = 4 9 9 0 . 9 7 PV I S T A = 1 5 + 4 8 . 4 7 PV I E L E V = 4 9 9 1 . 1 8 PV I S T A = 1 8 + 7 4 . 8 7 PV I E L E V = 4 9 9 1 . 2 1 75.0' VC HP ELEV = 4991.92 HP STA = 17+15.29 PVI STA = 17+15.29 PVI ELEV = 4992.01 BV C S : 1 6 + 7 7 . 7 9 BV C E : 4 9 9 1 . 8 2 EV C S : 1 7 + 5 2 . 7 9 EV C E : 4 9 9 1 . 8 2 A.D. = 1.00 K = 75.00 PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 14+00 15+00 16+00 17+00 18+00 19+00 19+50 49 8 8 . 1 2 49 8 8 . 0 9 49 8 8 . 0 3 49 8 7 . 9 2 49 8 7 . 7 8 49 8 7 . 6 3 49 8 7 . 5 0 49 8 7 . 3 8 49 8 7 . 2 3 49 8 6 . 8 7 49 8 7 . 1 0 49 8 7 . 0 1 49 8 6 . 8 6 49 8 6 . 7 5 49 8 6 . 5 8 49 8 6 . 4 9 49 8 5 . 9 5 49 8 6 . 1 4 49 8 6 . 0 7 0.50%0.50%-0.50% 0.60% PV I S T A = 1 4 + 1 2 . 7 6 PV I E L E V = 4 9 8 9 . 8 4 PV I S T A = 1 5 + 3 0 . 4 0 PV I E L E V = 4 9 9 0 . 5 5 PV I S T A = 1 5 + 7 2 . 0 1 PV I E L E V = 4 9 9 0 . 7 6 PV I S T A = 1 8 + 9 8 . 4 0 PV I E L E V = 4 9 9 0 . 7 9 75.0' VC HP ELEV = 4991.50 HP STA = 17+38.83 PVI STA = 17+38.83 PVI ELEV = 4991.59 BV C S : 1 7 + 0 1 . 3 3 BV C E : 4 9 9 1 . 4 0 EV C S : 1 7 + 7 6 . 3 3 EV C E : 4 9 9 1 . 4 0 A.D. = 1.00 K = 75.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 14+00 15+00 16+00 17+00 18+00 19+00 19+50 49 8 8 . 0 7 49 8 7 . 9 6 49 8 7 . 8 4 49 8 7 . 7 1 49 8 7 . 5 5 49 8 7 . 4 7 49 8 7 . 5 5 49 8 7 . 2 3 49 8 7 . 0 4 49 8 7 . 0 4 49 8 6 . 9 3 49 8 6 . 7 3 49 8 6 . 6 1 49 8 6 . 6 2 49 8 6 . 3 7 49 8 6 . 1 7 49 8 6 . 1 3 49 8 5 . 9 5 -0.50% 0.50%0.60%0.50% PV I S T A = 1 4 + 9 0 . 3 2 PV I E L E V = 4 9 9 0 . 5 5 PV I S T A = 1 5 + 2 5 . 0 0 PV I E L E V = 4 9 9 0 . 7 6 PV I S T A = 1 7 + 2 9 . 3 1 PV I E L E V = 4 9 9 1 . 4 0 PV I S T A = 1 8 + 5 1 . 3 9 PV I E L E V = 4 9 9 0 . 7 9 75.0' VC HP ELEV = 4991.50 HP STA = 16+91.81 PVI STA = 16+91.81 PVI ELEV = 4991.59 BV C S : 1 6 + 5 4 . 3 1 BV C E : 4 9 9 1 . 4 0 EV C S : 1 7 + 2 9 . 3 1 EV C E : 4 9 9 1 . 4 0 A.D. = 1.00 K = 75.00 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R5 PL A N & P R O F I L E SA I N T J E R O M E S T R E E T 34 NORTH CENTERLINE SAINT JEROME STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE SAINT JOSEPH STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE SAINT JOSEPH STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT ST A MA T C H L I N E SE E S H E E T 14 + 0 0 R4 L I N E M A T C H S T A 1 3 + 0 0 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R4 R5 X X X X X X X X STA. = 11+59.16 (MOLLER STREET) STA. = 16+92.46 (SAINT THERESE STREET) STA. = 14+70.43 (MOLLER STREET) STA. = 16+65.36 (SAINT JEROME STREET) 30' - 57' ROW 30' - 57' ROW 5' SIDEWALK 5' SIDEWALK5' SIDEWALK 5' SIDEWALK MOLLER STREETPROPOSED BARRICADES SAINT THERESE STREET (SEE SHEET R2) SAINT JEROME STREET (SEE SHEET R4) LOT 1 LOT 1 LOT 6 LOT 5 LOT 8 LOT 7 LOT 9LOT 13 BLOCK 4 BLOCK 5 BLOCK 6 BLOCK 2 BLOCK 3 6' CONCRETE PAN PROPOSED DRIVEOVER CURB & GUTTER PROPOSED DRIVEOVER CURB & GUTTER UTILITY EASEMENT 15' UTILITY EASEMENT UTILITY EASEMENT 15' UTILITY EASEMENT LOT 14 TRACT D TRACT C DE LOT 6 LOT 7LOT 4 LOT 5 LOT 10 6' CONCRETE PAN R25' R25' R25' R25' R25' R25' PROPOSED STORM DRAINSTORM DRAIN A SEE SHEET ST1 FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) PROPOSED 2' SIDEWALK CHASE 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 1 . 7 8 49 9 1 . 8 3 49 9 1 . 9 5 49 9 2 . 0 8 49 9 2 . 2 0 49 9 2 . 3 3 49 9 2 . 4 5 49 9 2 . 5 8 49 9 2 . 7 0 49 9 2 . 8 3 49 9 2 . 9 1 49 9 2 . 9 1 49 9 2 . 8 3 49 9 2 . 7 1 49 9 2 . 5 8 49 9 2 . 3 7 49 9 1 . 9 7 49 9 1 . 4 7 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 2.20%-2.00% -0.50% -0.24% 0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 1 . 7 8 PV I S T A = 1 4 + 7 0 . 4 3 PV I E L E V = 4 9 9 1 . 7 6 PV I S T A = 1 4 + 5 3 . 5 9 PV I E L E V = 4 9 9 1 . 3 0 75.0' VC HP ELEV = 4992.92 HP STA = 12+88.16 PVI STA = 12+88.16 PVI ELEV = 4993.02 BV C S : 1 2 + 5 0 . 6 6 BV C E : 4 9 9 2 . 8 3 EV C S : 1 3 + 2 5 . 6 6 EV C E : 4 9 9 2 . 8 3 A.D. = 1.00 K = 75.00 50.0' VC PVI STA = 14+00.59 PVI ELEV = 4992.46 BV C S : 1 3 + 7 5 . 5 9 BV C E : 4 9 9 2 . 5 8 EV C S : 1 4 + 2 5 . 5 9 EV C E : 4 9 9 1 . 9 6 A.D. = 1.50 K = 33.33 55.5' VC LP ELEV = 4991.76 LP STA = 10+18.03 PVI STA = 10+27.78 PVI ELEV = 4991.72 BC V S : 1 0 + 0 0 . 0 3 BV C E : 4 9 9 1 . 7 8 EC V S : 1 0 + 5 5 . 5 3 EV C E : 4 9 9 1 . 8 5 A.D. = 0.74 K = 74.99 30" RCP STA.=10+18.03 INV.=4986.77 -0.24%-0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 1 . 7 8 19.5' VC PVI STA = 9+90.26 PVI ELEV = 4991.81 BV C S : 9 + 8 0 . 5 2 BV C E : 4 9 9 1 . 8 5 EV C S : 9 + 9 9 . 9 9 EV C E : 4 9 9 1 . 7 8 A.D. = 0.26 K = 74.92 -0.24%-0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 1 . 7 8 19.5' VC PVI STA = 9+90.26 PVI ELEV = 4991.81 BV C S : 9 + 8 0 . 5 2 BV C E : 4 9 9 1 . 8 5 EV C S : 9 + 9 9 . 9 9 EV C E : 4 9 9 1 . 7 8 A.D. = 0.26 K = 74.92 FUTURE GRADE FUTURE 15" HDPE IRRIGATION STA.=9+93.92 INV.=4982.23 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 1 . 2 8 49 9 1 . 4 1 49 9 1 . 5 3 49 9 1 . 6 6 49 9 1 . 7 8 49 9 1 . 9 1 49 9 2 . 0 3 49 9 2 . 1 6 49 9 2 . 2 8 49 9 2 . 4 1 49 9 2 . 4 9 49 9 2 . 5 0 49 9 2 . 4 2 49 9 2 . 2 4 49 9 2 . 0 7 49 9 1 . 8 9 49 9 1 . 7 2 49 9 1 . 2 9 0.50%0.50%-0.70% -2.00%-0.50%0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 1 . 3 4 PV I S T A = 1 0 + 1 8 . 0 3 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 1 + 1 9 . 1 6 PV I E L E V = 4 9 9 1 . 7 5 PV I S T A = 1 1 + 9 9 . 1 6 PV I E L E V = 4 9 9 2 . 1 5 PV I S T A = 1 2 + 5 0 . 6 6 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 3 + 2 5 . 6 6 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 4 + 3 0 . 4 3 PV I E L E V = 4 9 9 1 . 6 8 PV I S T A = 1 4 + 5 3 . 5 9 PV I E L E V = 4 9 9 1 . 2 1 75.0' VC HP ELEV = 4992.51 HP STA = 12+88.16 PVI STA = 12+88.16 PVI ELEV = 4992.60 BV C S : 1 2 + 5 0 . 6 6 BV C E : 4 9 9 2 . 4 1 EV C S : 1 3 + 2 5 . 6 6 EV C E : 4 9 9 2 . 4 1 A.D. = 1.00 K = 75.35 0.50%0.50%-0.70% -2.00%-0.50%0.50% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 1 . 3 4 PV I S T A = 1 1 + 9 9 . 1 6 PV I E L E V = 4 9 9 2 . 1 5 PV I S T A = 1 2 + 5 0 . 6 6 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 3 + 2 5 . 6 6 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 4 + 3 0 . 4 3 PV I E L E V = 4 9 9 1 . 6 8 PV I S T A = 1 4 + 5 3 . 5 9 PV I E L E V = 4 9 9 1 . 2 1 PV I S T A = 1 0 + 1 8 . 0 3 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 1 + 1 9 . 1 6 PV I E L E V = 4 9 9 1 . 7 5 75.0' VC HP ELEV = 4992.51 HP STA = 12+88.16 PVI STA = 12+88.16 PVI ELEV = 4992.60 BV C S : 1 2 + 5 0 . 6 6 BV C E : 4 9 9 2 . 4 1 EV C S : 1 3 + 2 5 . 6 6 EV C E : 4 9 9 2 . 4 1 A.D. = 1.00 K = 75.35 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 9+50 10+00 11+00 12+00 13+00 14+00 15+00 49 9 1 . 3 4 49 9 1 . 2 8 49 9 1 . 4 1 49 9 1 . 5 3 49 9 1 . 6 6 49 9 1 . 7 8 49 9 1 . 9 1 49 9 2 . 0 3 49 9 2 . 1 6 49 9 2 . 2 8 49 9 2 . 4 1 49 9 2 . 4 9 49 9 2 . 5 0 49 9 2 . 4 2 49 9 2 . 2 9 49 9 2 . 1 6 49 9 1 . 9 2 49 9 1 . 6 7 49 9 1 . 4 2 -0.50%0.50% 0.50%-0.50%-1.00%-1.00% PV I S T A = 9 + 9 9 . 9 9 PV I E L E V = 4 9 9 1 . 3 4 PV I S T A = 1 0 + 1 8 . 0 3 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 1 + 1 9 . 1 6 PV I E L E V = 4 9 9 1 . 7 5 PV I S T A = 1 3 + 7 5 . 5 9 PV I E L E V = 4 9 9 2 . 1 6 PV I S T A = 1 4 + 3 0 . 4 3 PV I E L E V = 4 9 9 1 . 6 1 PV I S T A = 1 4 + 5 3 . 5 9 PV I E L E V = 4 9 9 1 . 3 8 75.0' VC HP ELEV = 4992.51 HP STA = 12+88.13 PVI STA = 12+88.16 PVI ELEV = 4992.60 BV C S : 1 2 + 5 0 . 6 6 BV C E : 4 9 9 2 . 4 1 EV C S : 1 3 + 2 5 . 6 6 EV C E : 4 9 9 2 . 4 1 A.D. = 1.00 K = 74.93 -0.50%0.50% 0.50%-0.50%-1.00%-1.00% PV I S T A = 9 + 9 9 . 9 9 PV I E L E V = 4 9 9 1 . 3 4 PV I S T A = 1 0 + 1 8 . 0 3 PV I E L E V = 4 9 9 1 . 2 5 PV I S T A = 1 1 + 1 9 . 1 6 PV I E L E V = 4 9 9 1 . 7 5 PV I S T A = 1 2 + 5 0 . 6 6 PV I E L E V = 4 9 9 2 . 4 1 PV I S T A = 1 3 + 7 5 . 5 9 PV I E L E V = 4 9 9 2 . 1 6 PV I S T A = 1 4 + 3 0 . 4 3 PV I E L E V = 4 9 9 1 . 6 1 PV I S T A = 1 4 + 5 3 . 5 9 PV I E L E V = 4 9 9 1 . 3 8 75.0' VC HP ELEV = 4992.51 HP STA = 12+88.13 PVI STA = 12+88.16 PVI ELEV = 4992.60 BV C S : 1 2 + 5 0 . 6 6 BV C E : 4 9 9 2 . 4 1 EV C S : 1 3 + 2 5 . 6 6 EV C E : 4 9 9 2 . 4 1 A.D. = 1.00 K = 74.93 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R6 PL A N & P R O F I L E MO L L E R S T R E E T 35 NORTH CENTERLINE MOLLER STREET SCALE : 1" = 40' (H) 1" = 5' (V) LEFT FLOWLINE MOLLER STREET SCALE : 1" = 40' (H) 1" = 5' (V) RIGHT FLOWLINE MOLLER STREET SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R R6 KEYMAP T WEST WILLOX LANE SOFT GOLD PARK / / / / / / / / / / / / / / / / / / / / / / / / S S S MS W W WM W W S MM W XXXXX X / / / / / / / // / / / / / / / XX X / / / / / / / // / / / / / / // / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / // / / / / / / / / / / / / / / / X X / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / E E WEST WILLOX LANE 6' SIDEWALK EXISTING 6' CITY OF FORT COLLINS EASEMENT57' ROW 30' - 9' U T I L I T Y E A S E M E N T 6' SIDEWALK 9' U T I L I T Y E A S E M E N T ±40' EOA -  SAINT THERESE STREET (SEE SHEET R1) TRACT A DE,UE,AE PROPOSED 4' SIDEWALK CULVERT EXISTING ROW EXISTING 10' ROW EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING DRIVEWAY EXISTING DRIVEWAY EXISTING EDGE OF ASPHALT TIE TO EXISTING EDGE OF ASPHALT PROPOSED 10' CONCRETE PAN 100' UNION PACIFIC RAILROAD ROW 72' ROW 18' UTILITY EASEMENT 18' UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT PROPOSED EDGE OF ASPHALT EDGE OF PROPOSED SAW CUT EX. 12" RCP EX. 15" METAL PIPE WILLOX STORM DRAIN SEE SHEET ST3 WILLOX EAST STORM DRAIN SEE SHEET ST3 FUTURE CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LINE (BY OTHERS) PROPOSED 30" VERTICAL CURB & GUTTER TIE TO EXISTING EDGE OF ASPHALT PROPOSED EDGE OF ASPHALT RR CROSSING SIGN (W10-1) 30 MPH SPEED LIMIT EXISTING DRIVEWAY PROPOSED 4' CONCRETE PAN w/ 7" CURBS PROPOSED 2' CONCRETE PANTRACT B DE STA. = 21+58.46 (WEST WILLOX LANE) STA. = 10+00.00 (SAINT THERESE STREET) 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 17+50 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 27+50 49 9 3 . 2 3 49 9 2 . 7 9 49 9 3 . 0 7 49 9 2 . 7 7 49 9 2 . 3 5 49 9 2 . 5 5 49 9 3 . 0 1 49 9 2 . 9 0 49 9 2 . 7 5 49 9 3 . 0 5 49 9 3 . 4 7 49 9 3 . 0 2 49 9 2 . 8 8 49 9 2 . 8 0 49 9 2 . 8 5 49 9 2 . 9 6 49 9 3 . 0 4 49 9 3 . 0 6 49 9 3 . 0 0 49 9 2 . 8 9 49 9 2 . 6 4 49 9 2 . 5 2 49 9 2 . 4 1 49 9 2 . 3 3 49 9 2 . 3 6 49 9 2 . 4 3 49 9 2 . 6 8 49 9 2 . 8 0 49 9 2 . 9 2 49 9 3 . 0 5 49 9 3 . 0 5 49 9 2 . 9 9 49 9 2 . 7 9 49 9 2 . 7 3 49 9 2 . 7 2 49 9 2 . 8 3 49 9 2 . 9 4 49 9 3 . 0 2 49 9 3 . 0 4 0.50%-0.50% -0.95% 135.0' VC HP ELEV = 4993.08 HP STA = 20+04.75 PVI STA = 20+04.75 PVI ELEV = 4993.24 BV C S : 1 9 + 3 7 . 2 5 BV C E : 4 9 9 2 . 9 1 EV C S : 2 0 + 7 2 . 2 5 EV C E : 4 9 9 2 . 9 1 A.D. = 1.00 K = 135.00 135.0' VC HP ELEV = 4993.06 HP STA = 24+34.55 PVI STA = 24+34.57 PVI ELEV = 4993.22 BV C S : 2 3 + 6 7 . 0 7 BV C E : 4 9 9 2 . 8 9 EV C S : 2 5 + 0 2 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 134.95 135.0' VC HP ELEV = 4993.05 HP STA = 27+04.57 PVI STA = 27+04.57 PVI ELEV = 4993.22 BV C S : 2 6 + 3 7 . 0 7 BV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 135.00 135.0' VC LOW PT ELEV = 4992.79 LOW PT STA = 18+90.70 PVI STA = 18+69.75 PVI ELEV = 4992.57 BV C S : 1 8 + 0 2 . 2 5 BV C E : 4 9 9 3 . 2 1 EV C S : 1 9 + 3 7 . 2 5 EV C E : 4 9 9 2 . 9 1 A.D. = 1.45 K = 93.10 135.0' VC LOW PT ELEV = 4992.33 LOW PT STA = 22+21.64 PVI STA = 22+21.64 PVI ELEV = 4992.16 BV C S : 2 1 + 5 4 . 1 4 BV C E : 4 9 9 2 . 5 0 EV C S : 2 2 + 8 9 . 1 4 EV C E : 4 9 9 2 . 5 0 A.D. = 1.00 K = 135.00 135.0' VC LOW PT ELEV = 4992.72 LOW PT STA = 25+69.59 PVI STA = 25+69.57 PVI ELEV = 4992.55 BV C S : 2 5 + 0 2 . 0 7 BV C E : 4 9 9 2 . 8 9 EV C S : 2 6 + 3 7 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 134.95 EXISTING GROUND FUTURE GRADE EXISTING GROUND FUTURE GRADE 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 PV I S T A = 2 2 + 2 5 . 0 0 PV I E L E V = 4 9 9 1 . 4 8 75.6' VC HP ELEV = 4992.40 HP STA = 20+08.14 PVI STA = 20+37.82 PVI ELEV = 4992.42 BV C S : 2 0 + 0 0 BV C E : 4 9 9 2 . 3 9 EV C S : 2 0 + 7 5 . 6 4 EV C E : 4 9 9 2 . 2 3 A.D. = 0.56 K = 134.99 95.0' VC HP ELEV = 4992.46 HP STA = 24+54.60 PVI STA = 24+34.58 PVI ELEV = 4992.53 BV C S : 2 3 + 8 7 . 0 8 BV C E : 4 9 9 2 . 2 9 EV C S : 2 4 + 8 2 . 0 8 EV C E : 4 9 9 2 . 4 3 A.D. = 0.70 K = 135.04 49 9 2 . 3 9 49 9 2 . 3 9 49 9 2 . 3 3 49 9 2 . 2 3 49 9 2 . 1 1 49 9 1 . 9 8 49 9 1 . 8 6 49 9 1 . 7 3 49 9 1 . 6 1 49 9 1 . 4 8 49 9 1 . 6 1 49 9 1 . 7 3 49 9 1 . 8 6 49 9 1 . 9 8 49 9 2 . 1 1 49 9 2 . 2 3 49 9 2 . 3 5 49 9 2 . 4 3 49 9 2 . 4 6 49 9 2 . 4 4 EXISTING GROUND PROPOSED GRADE 0.50% 59.4' VC PVI STA = 19+70.32 PVI ELEV = 4992.38 BV C S : 1 9 + 4 0 . 6 4 BV C E : 4 9 9 2 . 2 3 EV C S : 2 0 + 0 0 EV C E : 4 9 9 2 . 3 9 A.D. = 0.44 K = 135.00 40.0' VC PVI STA = 25+02.11 PVI ELEV = 4992.39 BV C S : 2 4 + 8 2 . 1 1 BV C E : 4 9 9 2 . 4 3 EV C S : 2 5 + 2 2 . 1 1 EV C E : 4 9 9 2 . 2 9 A.D. = 0.30 K = 134.90 PROPOSED GRADE 0.50%-0.50% EXISTING GROUND FUTURE GRADE FUTURE GRADE PROPOSED GROUND PROPOSED GROUND Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R7 PL A N & P R O F I L E WE S T W I L L O X L A N E - R I G H T F L O W L I N E 36 NORTH CENTER LINE WEST WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP T WEST WILLOX LANE SOFT GOLD PARK RIGHT FLOWLINE WEST WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) R7 XXXXXXXXXXXXXX X X XXXXXXXXXXXXXXX X W W W W W W W W W W W 52' FUTURE  -  EXISTING 10' UTILITY EASEMENT EXISTING 30' NCWA EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 84' FUTURE ROW WEST WILLOX LANE EX. 24" RCP FUTURE 30" CURB & GUTTER FUTURE 30" CURB & GUTTER FUTURE ROW FUTURE ROW FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK EXISTING DRIVEWAY 4980 4985 4990 4995 5000 5005 5010 5015 4980 4985 4990 4995 5000 5005 5010 5015 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 49 9 6 . 8 2 49 9 7 . 5 8 49 9 8 . 7 7 49 9 9 . 0 1 49 9 8 . 0 7 49 9 6 . 5 7 49 9 5 . 1 5 49 9 4 . 1 8 49 9 6 . 9 5 49 9 7 . 1 2 49 9 7 . 3 3 49 9 7 . 8 8 49 9 8 . 2 1 49 9 8 . 5 3 49 9 8 . 9 4 49 9 9 . 0 4 49 9 9 . 0 6 49 9 8 . 8 9 49 9 8 . 6 9 49 9 8 . 4 1 49 9 7 . 6 9 49 9 7 . 3 2 49 9 6 . 9 4 49 9 6 . 1 9 49 9 5 . 8 2 49 9 5 . 4 7 49 9 4 . 8 6 49 9 4 . 6 1 49 9 4 . 3 9 49 9 3 . 9 4 49 9 3 . 7 1 49 9 3 . 4 7 FUTURE GRADE EXISTING GROUND FUTURE GRADE EXISTING GROUND 0.50% 1.40% -1.50% -0.80% -0.95% PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 6 . 8 2 PV I S T A = 1 6 + 9 5 . 8 4 PV I E L E V = 4 9 9 4 . 2 2 245.0' VC HP ELEV = 4999.06 HP STA = 12+70.01 PVI STA = 12+74.23 PVI ELEV = 4999.95 BV C S : 1 1 + 5 1 . 7 3 BV C E : 4 9 9 8 . 2 4 EV C S : 1 3 + 9 6 . 7 3 EV C E : 4 9 9 8 . 1 1 A.D. = 2.90 K = 84.48 PV I S T A = 1 0 + 0 0 . 0 0 PV I E L E V = 4 9 9 6 . 8 2 PV I S T A = 1 6 + 9 5 . 8 4 PV I E L E V = 4 9 9 4 . 2 2 135.0' VC PVI STA = 10+79.06 PVI ELEV = 4997.22 BC V S : 1 0 + 1 1 . 5 6 BV C E : 4 9 9 6 . 8 8 EC V S : 1 1 + 4 6 . 5 6 EV C E : 4 9 9 8 . 1 6 A.D. = 0.90 K = 150.00 135.0' VC PVI STA = 16+11.05 PVI ELEV = 4994.90 BC V S : 1 5 + 4 3 . 5 5 BV C E : 4 9 9 5 . 9 1 EC V S : 1 6 + 7 8 . 5 5 EV C E : 4 9 9 4 . 3 6 A.D. = 0.70 K = 192.86 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R8 PL A N & P R O F I L E WE S T W I L L O X L A N E ( U L T I M A T E ) 37 NORTH CENTER LINE W. WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R LI N E MA T C H ST A 18 + 0 0 ST A MA T C H L I N E SE E S H E E T 18 + 0 0 R9 KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R9 R8 R10 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED STORM INLET EXISTING EDGE OF ASPHALT FUTURE CURB & GUTTER FUTURE RIGHT-OF-WAY 4980 4985 4990 4995 5000 5005 5010 5015 4980 4985 4990 4995 5000 5005 5010 5015 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 26+50 FUTURE GRADE EXISTING GROUND FUTURE GRADE EXISTING GROUND 0.50%-0.50% -0.95% 135.0' VC HP ELEV = 4993.08 HP STA = 20+04.75 PVI STA = 20+04.75 PVI ELEV = 4993.24 BV C S : 1 9 + 3 7 . 2 5 BV C E : 4 9 9 2 . 9 1 EV C S : 2 0 + 7 2 . 2 5 EV C E : 4 9 9 2 . 9 1 A.D. = 1.00 K = 135.00 135.0' VC HP ELEV = 4993.06 HP STA = 24+34.55 PVI STA = 24+34.57 PVI ELEV = 4993.22 BV C S : 2 3 + 6 7 . 0 7 BV C E : 4 9 9 2 . 8 9 EV C S : 2 5 + 0 2 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 134.95 BV C S : 2 6 + 3 7 . 0 7 BV C E : 4 9 9 2 . 8 9 135.0' VC LP ELEV = 4992.79 LP STA = 18+90.70 PVI STA = 18+69.75 PVI ELEV = 4992.57 BC V S : 1 8 + 0 2 . 2 5 BV C E : 4 9 9 3 . 2 1 EC V S : 1 9 + 3 7 . 2 5 EV C E : 4 9 9 2 . 9 1 A.D. = 1.45 K = 93.10 135.0' VC LP ELEV = 4992.33 LP STA = 22+21.64 PVI STA = 22+21.64 PVI ELEV = 4992.16 BC V S : 2 1 + 5 4 . 1 4 BV C E : 4 9 9 2 . 5 0 EC V S : 2 2 + 8 9 . 1 4 EV C E : 4 9 9 2 . 5 0 A.D. = 1.00 K = 135.00 135.0' VC LP ELEV = 4992.72 LP STA = 25+69.59 PVI STA = 25+69.57 PVI ELEV = 4992.55 BC V S : 2 5 + 0 2 . 0 7 BV C E : 4 9 9 2 . 8 9 EC V S : 2 6 + 3 7 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 134.95 49 9 3 . 0 2 49 9 2 . 8 8 49 9 2 . 8 0 49 9 2 . 7 9 49 9 2 . 8 5 49 9 2 . 9 6 49 9 3 . 0 4 49 9 3 . 0 7 49 9 3 . 0 6 49 9 3 . 0 0 49 9 2 . 8 9 49 9 2 . 7 7 49 9 2 . 6 4 49 9 2 . 5 2 49 9 2 . 4 1 49 9 2 . 3 5 49 9 2 . 3 3 49 9 2 . 3 6 49 9 2 . 4 3 49 9 2 . 5 5 49 9 2 . 6 8 49 9 2 . 8 0 49 9 2 . 9 2 49 9 3 . 0 1 49 9 3 . 0 5 49 9 3 . 0 5 49 9 2 . 9 9 49 9 2 . 9 0 49 9 2 . 7 9 49 9 2 . 7 3 49 9 2 . 7 2 49 9 2 . 7 5 49 9 2 . 8 3 S XXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X E E WEST WILLOX LANE 6' SIDEWALK 84' FUTURE ROW EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 30' NCWA EASEMENT 57' ROW 30' - 9' U T I L I T Y E A S E M E N T 6' SIDEWALK 9' U T I L I T Y E A S E M E N T FUTURE IRRIGATION PIPE 52' FUTURE  -  SAINT THERESE STREET (SEE SHEET R1) TRACT A DE,UE,AE EX. 15" METAL EX. 12" RCP EXISTING DRIVEWAY EXISTING DRIVEWAY EXISTING DRIVEWAY FUTURE 30" CURB & GUTTER FUTURE 30" CURB & GUTTER FUTURE 30" CURB & GUTTER PROPOSED 30" CURB & GUTTER PROPOSED 30" CURB & GUTTER FUTURE ROW FUTURE ROW FUTURE ROW FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK 18' UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT TRACT B DE PROPOSED 4' SIDEWALK CULVERT 4980 4985 4990 4995 5000 5005 4980 4985 4990 4995 5000 5005 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 26+50 49 9 2 . 3 9 49 9 2 . 3 9 49 9 2 . 3 3 49 9 2 . 2 3 49 9 2 . 1 1 49 9 1 . 9 8 49 9 1 . 8 6 49 9 1 . 7 3 49 9 1 . 6 1 49 9 1 . 4 8 49 9 1 . 6 1 49 9 1 . 7 3 49 9 1 . 8 6 49 9 1 . 9 8 49 9 2 . 1 1 49 9 2 . 2 3 49 9 2 . 3 5 49 9 2 . 4 3 49 9 2 . 4 6 49 9 2 . 4 4 0.50%-0.50% PV I S T A = 2 2 + 2 5 . 0 0 PV I E L E V = 4 9 9 1 . 4 8 75.6' VC HP ELEV = 4992.40 HP STA = 20+08.14 PVI STA = 20+37.82 PVI ELEV = 4992.42 BV C S : 2 0 + 0 0 BV C E : 4 9 9 2 . 3 9 EV C S : 2 0 + 7 5 . 6 4 EV C E : 4 9 9 2 . 2 3 A.D. = 0.56 K = 134.99 95.0' VC HP ELEV = 4992.46 HP STA = 24+54.60 PVI STA = 24+34.58 PVI ELEV = 4992.53 BV C S : 2 3 + 8 7 . 0 8 BV C E : 4 9 9 2 . 2 9 EV C S : 2 4 + 8 2 . 0 8 EV C E : 4 9 9 2 . 4 3 A.D. = 0.70 K = 135.04 0.50% PV I S T A = 1 9 + 4 0 . 6 4 PV I E L E V = 4 9 9 2 . 2 3 59.4' VC PVI STA = 19+70.32 PVI ELEV = 4992.38 BV C S : 1 9 + 4 0 . 6 4 BV C E : 4 9 9 2 . 2 3 EV C S : 2 0 + 0 0 EV C E : 4 9 9 2 . 3 9 A.D. = 0.44 K = 135.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -0.50% PV I S T A = 2 5 + 2 2 . 2 1 PV I E L E V = 4 9 9 2 . 2 9 40.0' VC PVI STA = 25+02.11 PVI ELEV = 4992.39 BV C S : 2 4 + 8 2 . 1 1 BV C E : 4 9 9 2 . 4 3 EV C S : 2 5 + 2 2 . 1 1 EV C E : 4 9 9 2 . 2 9 A.D. = 0.30 K = 134.90 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R9 PL A N & P R O F I L E WE S T W I L L O X L A N E ( U L T I M A T E ) 38 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CENTER LINE W. WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) LI N E MA T C H ST A 26 + 5 0 ST A MA T C H L I N E SE E S H E E T 26 + 5 0 R1 0 ST A MA T C H L I N E SE E S H E E T 18 + 0 0 R8 LI N E MA T C H ST A 18 + 0 0 KEYMAP T WEST WILLOX LANE SOFT GOLD PARK EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED STORM INLET EXISTING EDGE OF ASPHALT FUTURE CURB & GUTTER FUTURE RIGHT-OF-WAY R9 R8 R10 RIGHT FLOWLINE W. WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) S X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXX X X X X X X OHUXWWW EXISTING 30' NCWA EASEMENT 52' FUTURE  -  84' FUTURE ROW FUTURE 6' SIDEWALK RAILROAD TRACKS 42"X72" CMP WEST WILLOX LANE EXISTING DRIVEWAY EXISTING DRIVEWAY EXISTING DRIVEWAY EXISTING DRIVEWAY N W H I T E C O M B S T . EXISTING DRIVEWAY FUTURE 30" CURB & GUTTER FUTURE 30" CURB & GUTTER FUTURE ROW FUTURE ROW FUTURE 6' SIDEWALK 100' UNION PACIFIC RAILROAD ROW 4980 4985 4990 4995 5000 5005 5010 5015 4980 4985 4990 4995 5000 5005 5010 5015 26+50 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 35+50 49 9 3 . 0 5 49 9 2 . 7 5 49 9 2 . 4 4 49 9 2 . 7 9 49 9 3 . 2 9 49 9 3 . 7 9 49 9 4 . 1 8 49 9 3 . 6 4 49 9 3 . 0 2 49 9 3 . 0 4 49 9 2 . 9 8 49 9 2 . 8 7 49 9 2 . 6 2 49 9 2 . 5 1 49 9 2 . 4 5 49 9 2 . 4 7 49 9 2 . 5 4 49 9 2 . 6 6 49 9 2 . 9 1 49 9 3 . 0 4 49 9 3 . 1 6 49 9 3 . 4 1 49 9 3 . 5 4 49 9 3 . 6 6 49 9 3 . 9 1 49 9 4 . 0 4 49 9 4 . 1 4 49 9 4 . 1 5 49 9 4 . 0 5 49 9 3 . 8 8 49 9 3 . 3 9 49 9 3 . 1 4 49 9 2 . 8 9 FUTURE GRADE EXISTING GROUND FUTURE GRADE EXISTING GROUND -1.00%0.50% -0.50% PV I S T A = 3 4 + 8 1 . 9 4 PV I E L E V = 4 9 9 2 . 8 3 135.0' VC HP ELEV = 4993.05 HP STA = 27+04.57 PVI STA = 27+04.57 PVI ELEV = 4993.22 EV C S : 2 7 + 7 2 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 135.00 135.0' VC HP ELEV = 4994.18 HP STA = 33+01.30 PVI STA = 33+23.80 PVI ELEV = 4994.41 BV C S : 3 2 + 5 6 . 3 0 BV C E : 4 9 9 4 . 0 7 EV C S : 3 3 + 9 1 . 3 0 EV C E : 4 9 9 3 . 7 3 A.D. = 1.50 K = 90.00 135.0' VC LP ELEV = 4992.44 LP STA = 28+95.89 PVI STA = 28+95.89 PVI ELEV = 4992.27 BC V S : 2 8 + 2 8 . 3 9 BV C E : 4 9 9 2 . 6 0 EC V S : 2 9 + 6 3 . 3 9 EV C E : 4 9 9 2 . 6 0 A.D. = 1.00 K = 135.00 -1.00%0.50% -0.50% PV I S T A = 3 4 + 8 1 . 9 4 PV I E L E V = 4 9 9 2 . 8 3 135.0' VC HP ELEV = 4993.05 HP STA = 27+04.57 PVI STA = 27+04.57 PVI ELEV = 4993.22 EV C S : 2 7 + 7 2 . 0 7 EV C E : 4 9 9 2 . 8 9 A.D. = 1.00 K = 135.00 135.0' VC HP ELEV = 4994.18 HP STA = 33+01.30 PVI STA = 33+23.80 PVI ELEV = 4994.41 BV C S : 3 2 + 5 6 . 3 0 BV C E : 4 9 9 4 . 0 7 EV C S : 3 3 + 9 1 . 3 0 EV C E : 4 9 9 3 . 7 3 A.D. = 1.50 K = 90.00 135.0' VC LP ELEV = 4992.44 LP STA = 28+95.89 PVI STA = 28+95.89 PVI ELEV = 4992.27 BC V S : 2 8 + 2 8 . 3 9 BV C E : 4 9 9 2 . 6 0 EC V S : 2 9 + 6 3 . 3 9 EV C E : 4 9 9 2 . 6 0 A.D. = 1.00 K = 135.00 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 R10 PL A N & P R O F I L E WE S T W I L L O X L A N E ( U L T I M A T E ) 39 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CENTER LINE W. WILLOX LANE SCALE : 1" = 40' (H) 1" = 5' (V) ST A MA T C H L I N E SE E S H E E T 26 + 5 0 R1 0 LI N E MA T C H ST A 26 + 5 0 KEYMAP T WEST WILLOX LANE SOFT GOLD PARK R10 R9 R11 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE EXISTING LOT LINE PROPOSED STORM INLET EXISTING EDGE OF ASPHALT FUTURE CURB & GUTTER FUTURE RIGHT-OF-WAY / / / / / / / / / / / / / / / / / / / / / / / / S 6' SIDEWALK EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 30' NCWA EASEMENT 57' ROW 30' - 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T SAINT THERESE STREET (SEE SHEET R1) WEST WILLOX LANE 11' TRAVEL LANE 11' TRAVEL LANE11' TRAVEL LANE 11' TRAVEL LANE 10' LEFT TURN LANE 6' SIDEWALK ±40' EOA -  A AH TIE INTO EXISTING STRIPING TIE INTO EXISTING STRIPING 2' SHOULDER (MIN.) 6' TRACT A DE,UE,AE PROPERTY BOUNDARY LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 18' UTILITY EASEMENT 18' UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 72' ROW 100' UNION PACIFIC RAILROAD ROW TRACT B DE STA.=19+52.96 OFFSET=11' BEGIN 1 CONCRETE DRIVEWAY STA.=19+01.07 OFFSET=11' BEGIN 1 STA.=18+93.49 OFFSET=0' BEGIN 8 STA.=24+95.55 OFFSET=11' END 1STA.=21+33.49 OFFSET=1' END 8 STA.=21+33.49 OFFSET=9' END 8 STA.=21+33.07 OFFSET=20' BEGIN 1 STA.=21+83.49 OFFSET=20' BEGIN 1 STA.=21+83.49 OFFSET=9' BEGIN 8 STA.=21+83.49 OFFSET=1' BEGIN 4 STA.=25+76.35 OFFSET=11' END 1 STA.=24+98.49 OFFSET=0' END 8 STA.=25+78.40 OFFSET=0' END 8 STA.=23+38.49 OFFSET=1' END 4 STA.=23+38.48 OFFSET=9' CONTINUE 8 STA.=23+38.70 OFFSET=20' CONTINUE 1 RAILROAD PAVEMENT MARKINGS SPEED LIMIT 30 MPH SIGN RR CROSSING SIGNSTOP SIGN EXISTING SPEED LIMIT 40 MPH SIGN Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SG1 IN T E R I M S I G N A G E & S T R I P I N G P L A N WE S T W I L L O X L A N E 40 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 / / / / / / / /PROPOSED EDGE OF ASPHALT PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: PROPOSED LOT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO LANDSCAPE PLANS FOR STREET TREE INFORMATION, AND SURVEY DOCUMENTS FOR ADDITIONAL RIGHT-OF-WAY AND EASEMENT INFORMATION. YELLOW ISLAND CROSS HATCHING10 WHITE ISLAND CROSS HATCHING 4" SOLID YELLOW LINE 4" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE 4" BROKEN YELLOW LINE 8" SOLID WHITE LINE DOUBLE YELLOW LINE 4" SOLID AND 4" BROKEN; 4" APART 9 6 3 5 1 8 2 4 7 STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 18" X 9' CROSSING LINE, SEE NOTES PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING 18" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING "STOP" (22.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) RIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING TWO WAY LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) L H D C B KA E F G I J M LANE REDUCTION ARROW PREFORMED PLASTIC PAVEMENT MARKING MEDIAN LINE YELLOW 18" WIDE1150' O.C. 45° ANGLES 10'30'10'30'10'4" BROKEN WHITE12 10' N "LANE ENDS" PREFORMED PLASTIC PAVEMENT MARKING 3'3'3'3'3'4" WHITE DASHED LINE O 18" WIDE WHITE MEDIAN STRIPING PREFORMED PLASTIC PAVEMENT MARKING A.ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. B.ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. C.ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. D.ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. E.ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT. F.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE TOWN OF TIMNATH AND CITY OF FORT COLLINS ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. G.PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. H.EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. I.ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. J.ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. K.A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. L.THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. M.SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. N.SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). O.SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. P.STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE. STRIPING LEGEND:STRIPING NOTES: 3'3'3'3'3'8" WHITE DASHED LINE (NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN) PAVEMENT STRIPING PAVEMENT MARKINGS STRAIGHT ARROW (15 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING 30'10'30'10' LEGEND: EXISTING PROPERTY BOUNDARY KEYMAP T WEST WILLOX LANE SOFT GOLD PARK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S WWWWWWWWWWWW W W W W W W W W W W 84 ' R O W EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT57' ROW 30' - 52'  -  A A H 3' BIKE LANE BUFFER STA.=21+33.51 OFFSET=5' END 8 STA.=21+33.51 OFFSET=16' END 1 STA.=21+33.51 OFFSET=19' END 1 ℄ STA.=21+83.51 OFFSET=5' BEGIN 4 STA.=21+83.51 OFFSET=5' BEGIN 7 ℄ STA.=21+83.51 OFFSET=16' BEGIN 1 ℄ STA.=21+83.51 OFFSET=19' BEGIN 1 TRACT A DE,UE,AE EXISTING PROPERTY BOUNDARY 6' SIDEWALK 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T SAINT THERESE STREET (SEE SHEET R1) WEST WILLOX LANE 11' TRAVEL LANE 11' TRAVEL LANE 6' SIDEWALK 10' CENTER LANE 7' BIKE LANE 18' UTILITY EASEMENT 18' UTILITY EASEMENT EXISTING 30' NCWA UTILITY EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 30' NCWA UTILITY EASEMENT 7' BIKE LANE STA.=21+33.51 OFFSET=5' END 8 7' BIKE LANE 11' TRAVEL LANE 10' TURN LANE 11' TRAVEL LANE 7' BIKE LANE ℄ STA.=24+18.51 OFFSET=5' END 4 STA.=24+18.51 OFFSET=5' CONTINUE 7 STA.=26+18.51 OFFSET=5' BEGIN 8 END 7 STA.=26+18.51 OFFSET=5' BEGIN 8 END 7 W W W W W W W W W W W 52'  -  EXISTING 10' ROW EASEMENT EXISTING 30' NCWA EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 84' ROW 3' BIKE LANE BUFFER 3' BIKE LANE BUFFER STA.=10+00.00 OFFSET=16' BEGIN 1 STA.=10+00.01 OFFSET=16' BEGIN 1 ℄ STA.=10+00.01 OFFSET=19' BEGIN 1 ℄ STA.=10+00.00 OFFSET=19' BEGIN 1 ℄ STA.=10+00.00 OFFSET=5' BEGIN 8 ℄ STA.=10+00.00 OFFSET=5' BEGIN 8 11' TRAVEL LANE 10' CENTER LANE 7' BIKE LANE LANE 6' SIDEWALK 6' SIDEWALK WEST WILLOX LANE 11' TRAVEL LANE 7' BIKE LANE LANE OHUWW 52'  - 84' ROW 11 TRAVEL LANE 11' TRAVEL LANE 10' CENTER LANE 7' BIKE LANE 7' BIKE LANE 6' SIDEWALK 6' SIDEWALK WEST WILLOX LANE Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 SG2 UL T I M A T E S I G N A G E & S T R I P I N G P L A N WE S T W I L L O X L A N E 41 NORTH SG2 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 / / / / / / / /PROPOSED EDGE OF ASPHALT PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: PROPOSED LOT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO LANDSCAPE PLANS FOR STREET TREE INFORMATION, AND SURVEY DOCUMENTS FOR ADDITIONAL RIGHT-OF-WAY AND EASEMENT INFORMATION. YELLOW ISLAND CROSS HATCHING10 WHITE ISLAND CROSS HATCHING 4" SOLID YELLOW LINE 4" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE 4" BROKEN YELLOW LINE 8" SOLID WHITE LINE DOUBLE YELLOW LINE 4" SOLID AND 4" BROKEN; 4" APART 9 6 3 5 1 8 2 4 7 STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 18" X 9' CROSSING LINE, SEE NOTES PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING 18" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING "STOP" (22.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) RIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING TWO WAY LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) L H D C B KA E F G I J M LANE REDUCTION ARROW PREFORMED PLASTIC PAVEMENT MARKING MEDIAN LINE YELLOW 18" WIDE1150' O.C. 45° ANGLES 10'30'10'30'10'4" BROKEN WHITE12 10' N "LANE ENDS" PREFORMED PLASTIC PAVEMENT MARKING 3'3'3'3'3'4" WHITE DASHED LINE O 18" WIDE WHITE MEDIAN STRIPING PREFORMED PLASTIC PAVEMENT MARKING A.ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. B.ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. C.ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. D.ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. E.ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT. F.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE TOWN OF TIMNATH AND CITY OF FORT COLLINS ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. G.PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. H.EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. I.ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. J.ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. K.A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. L.THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. M.SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. N.SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). O.SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. P.STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE. STRIPING LEGEND:STRIPING NOTES: 3'3'3'3'3'8" WHITE DASHED LINE (NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN) PAVEMENT STRIPING PAVEMENT MARKINGS STRAIGHT ARROW (15 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING 30'10'30'10' LEGEND: EXISTING PROPERTY BOUNDARY LI N E MA T C H ST A 18 + 0 0 LI N E MA T C H ST A 18 + 0 0 LI N E MA T C H ST A 26 + 5 0 LI N E MA T C H ST A 26 + 5 0 KEYMAP T WEST WILLOX LANE SOFT GOLD PARK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R S W W XXXXX X / / / / / / / // / / / / / / / / / / / / / / // / / / / / / // / / / / / / // / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / 18 + 5 0 19 + 0 0 19 + 5 0 20 + 0 0 20 + 5 0 21 + 0 0 21 + 5 0 22 + 0 0 22 + 5 0 WEST WILLOX LANE 18' UTILITY EASEMENT 26' CL-FL 42' HALF ROW PROPOSED 30" VERTICAL CURB & GUTTER 6' SIDEWALK WILLOX STORM WEST SEE SHEET ST3 TRACT B DE FUTURE IRRIGATION LINE (BY OTTHERS) SAINT THERESE STREET PROPOSED 4' SIDEWALK CULVERT SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 18+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 19+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 3 . 5 49 9 3 . 1 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 3 . 1 49 9 3 . 1 2 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 20+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 9 49 9 2 . 8 6 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 21+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 7 49 9 2 . 6 8 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 21+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 22+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 22+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 6 49 9 2 . 5 7 EXISTING GROUND PROPOSED GROUND PROPOSED GROUND EXISTING GROUND -2.33% -1.51% -1.68% -2.27% -3.35% -3.32% EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET XS1 IN T E R I M C R O S S - S E C T I O N S WE S T W I L L O X L A N E 42 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CROSS SECTION PROFILES WEST WILLOX LANE ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 XS2XS1 S T S S S W / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / E E E / / / / / / / / T 23 + 0 0 23 + 5 0 24 + 0 0 24 + 5 0 25 + 0 0 25 + 5 0 26 + 0 0 WEST WILLOX LANE 18' UTILITY EASEMENT 26' CL-FL 42' HALF ROW PROPOSED 30" VERTICAL CURB & GUTTER 6' SIDEWALK WILLOX STORM EAST SEE SHEET ST4 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 26+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 25+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 25+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 23+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 6 49 9 2 . 5 8 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 23+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 7 49 9 2 . 6 6 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 24+00 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 2 . 9 49 9 2 . 8 5 SE C T I O N LI N E Horizontal Scale 1" = 20' Vertical Scale 1" = 2' 24+50 4985 4988 4992 4996 5000 4985 4988 4992 4996 5000 0 20 400-20-40 49 9 3 . 1 49 9 3 . 0 8 49 9 3 . 1 49 9 3 . 2 49 9 3 . 3 EXISTING GROUND PROPOSED GROUND PROPOSED GROUND EXISTING GROUND -2.34% -1.62% -1.41% -1.91% EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET XS2 IN T E R I M C R O S S - S E C T I O N S WE S T W I L L O X L A N E 43 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CROSS SECTION PROFILES WEST WILLOX LANE ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 XS2XS1 W W W W W W X X X X X X X X X X X X OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU 92.65 92.07 92.009 2 . 0 1 9 1 . 6 1 9 1 . 6 2 9 2 . 0 7 9 2 . 3 2 9 2 . 6 5 91.739 1 . 8 9 SA I N T T H E R E S E ST R E E T WEST WILLOX LANE 6' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K 6' SIDEWALK 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER 30" VERTICAL CURB & GUTTER 9 2 . 6 5 1. 0 % 1. 0 % 1. 5 % 0. 9 % 0.5% 0.5% 1.2 % 0.5% 1. 0 % 92.55 2. 4 % LOT 1 LOT 2 0.5 % 0 . 5 % 92.08 0.5%0.5% 93.07 75 ' C R O W N T R A N S I T I O N 2.2%2.2% 9 2 . 1 1 9 2 . 1 1 92.02 9 1 . 6 5 91.52 91.77 91.84 9 1 . 8 4 9 1 . 8 1 9 1 . 5 3 9 1 . 0 9 9 1 . 0 7 9 1 . 1 0 9 0 . 7 5 9 0 . 7 5 9 1 . 2 2 1.3 % 91.37 1.0%1.0%0.6% 0. 5 % 0. 5 % 0. 2 % 0. 9 % 2 . 2 % 1. 5 % 1. 0 % 0. 7 % 1.0% 0.9%0.6% 9 2 . 2 6 2.2%2.2% 1. 3 % 1. 9 % 1.6% 1. 7 % 92.53 2.2%2.2% 60 ' C R O W N T R A N S I T I O N 35' CROWN TRANSITION 91.17 2. 2 % 2. 2 % 91.75 92.17 SA I N T T H E R E S E ST R E E T SAINT JOSEPH STREET 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK LOT 1 LOT 2 LOT 8 TRACT C DE 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' UTILITY EASEMENT 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER 1. 5 % 1. 5 % 0.9% 0.9% 0. 5 % 0. 5 % 9 2 . 2 2 92.03 92.149 2 . 1 5 91.88 92.23 9 1 . 7 6 9 1 . 7 5 9 1 . 7 5 91.77 9 1 . 8 8 9 2 . 2 3 92.03 92 . 1 4 9 2 . 1 5 92.23 92.8092.77 1. 0 % 1. 0 % 0.5% 1. 0 % 1. 0 % 92.779 2 . 7 7 92. 3 7 9 3 . 1 9 0.5%0.5% 2. 2 % 2. 2 % 1. 5 % 1. 5 % 2.2%2.2% 92.47 91.95 0.5%0.5% 91.95 0.5%0.5% 0.6 % 1. 5 % 0. 9 % 75 ' C R O W N T R A N S I T I O N 93.19 0.5%0.5% 0.5%0.5% 0.9% 1. 5 % 0. 8 % 92.27 9 2 . 3 1 75 ' C R O W N T R A N S I T I O N 1. 2 % 2.2%2.2% SA I N T T H E R E S E ST R E E T MOLLER STREET 5' SIDEWALK 5' SIDEWALK 5' S I D E W A L K 5' S I D E W A L K LOT 13 LOT 1 LOT 1 LOT 5 BLOCK 3 BLOCK 6 BLOCK 4 BLOCK 5 5' SIDEWALK 5' SIDEWALK 92.41 92.83 9 2 . 4 1 0.5% 0.5% 91.44 91.85 91.44 0.5% 0.5% 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 0 . 4 % 0 . 5 % 1.2 % 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER 9 1 . 1 4 9 1 . 1 6 9 1 . 6 8 91.61 9 2 . 1 6 9 2 . 1 6 91.49 91.51 91.27 91. 4 2 92.58 2. 2 % 2. 2 % 9 1 . 8 6 1.5% 1.0% 0.9%1.8% 0.9% 91.340. 5 % 0. 5 % 91.65 75' CROWN TRANSITION 0.5% 0. 5 % 0 . 5 % 0. 5 % 1.5% 9 1 . 7 6 9 1 . 5 6 9 1 . 1 4 2.2%2.2% 0. 5 % 9 1 . 9 1 91.49 2.2%2.2% 0. 5 % 9 1 . 3 4 0. 5 % 0. 5 % MOLLER STREET 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' S I D E W A L K 5' SIDEWALK 5' SIDEWALK 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T BLOCK 6 BLOCK 2 BLOCK 5 LOT 9 LOT 6 LOT 8 LOT 7 LOT 6 LOT 14 TRACT C DE TRACT D 0. 5 % 0. 5 % 0.5% 0.5% 9' U T I L I T Y E A S E M E N T 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER 75 ' V E R T I C A L C U R V E Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R A INTERSECTION DETAIL B INTERSECTION DETAIL C INTERSECTION DETAIL D INTERSECTION DETAIL A B C D NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT INT1 IN T E R S E C T I O N D E T A I L S 44 91.25 91. 6 7 91.25 91.48 9 1 . 5 6 92.13 91.72 2. 1 % 2. 2 % 2. 2 % 2. 2 % 0.7% 1 . 2 % 92.1992.6092.06 2.0%2.2% 92.18 0. 6 % 1. 0 % 9 2 . 6 5 9 3 . 0 7 9 2 . 6 5 2.2%2.2% 0. 7 % 0. 7 % 0 . 6 % 0.5% 0.5% LOT 1 LOT 2 BLOCK 6 BLOCK 3 LOT 10 LOT 8 LOT 9 SAINT GRACE STREET SA I N T T H E R E S E ST R E E T 0. 5 % 0. 5 % 0.5% 0.5% 5' SIDEWALK 9' U T I L I T Y E A S E M E N T 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 5' S I D E W A L K 5' SIDEWALK 9' UTILITY EASE M E N T 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER U D 90.65 9 0 . 6 2 9 0 . 3 8 9 0 . 1 9 89.92 9 0 . 0 8 90.30 90.65 90.65 9 0 . 3 8 90.30 90.42 0.5% 0.9% 0.9% 0.5% 0.5 % 0.5% 0.5 % 0. 5 % 0 . 9 % 0 . 9 % 1 . 0 % 91.07 75' CROWN TRANSITION 75 ' C R O W N T R A N S I T I O N 90.15 1 . 0 % 91.06 2.2%2.2% 2. 2 % 2. 2 % 9 0 . 5 4 1.0% 90.67 0. 9 % 1.2 % SA I N T J E R O M E ST R E E T SAINT GRACE STREET TRACT D LOT 10 LOT 9 BLOCK 6 LOT 1 LOT 2LOT 3 BLOCK 3 TRACT A DE,UE,AE LOT 14 LOT 13 LOT 12 BLOCK 2 0.5% 0.5% 5' SIDEWALK 9' UTILITY EASEMENT 5' SIDEWALK 5' S I D E W A L K 9' U T I L I T Y E A S E M E N T 9' U T I L I T Y E A S E M E N T 5' S I D E W A L K 31" DRIVEOVER CURB & GUTTER 31" DRIVEOVER CURB & GUTTER 90.57 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH E INTERSECTION DETAIL F INTERSECTION DETAIL E F ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET EASEMENT EDGE OF ASPHALT INT2 IN T E R S E C T I O N D E T A I L S 45 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D1 WA T E R D E T A I L S 46 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 100 WATER MAIN BEDDING REQUIREMENTS 103 WATER MAIN LOWERING ANCHOR BLOCKS 101 FIRE HYDRANT INSTALLATION 102 WATER MAIN LOWERING 105 TRAFFIC-RATED CURB STOP INSTALLATION 104 TYPICAL WATER SERVICE STEEL CASING 106 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D2 WA T E R D E T A I L S 47 202 PVC WATER MAIN TRACER WIRE 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 STREET ST R E E T VALVE (TYP.) HYDRANT SECONDARY FIRE HYDRANT (NOTE 4) LOCATOR STATION, TYP. PVC MAIN TRACER WIRE 800' MAXIMUM DISTANCE BETWEEN LOCATOR STATIONS 6 SEE NOTE 6 (TYP.) VALVE (TYP.) WATER MAIN GROUNDING ROD, TYP. (NOTE 5) NOTES: 1.TRACER WIRE TO BE PLACED ALONG TOP CENTERLINE OF MAIN AND SECURED AS NECESSARY TO PREVENT MOVEMENT OF WIRE. 2.TRACER WIRE SHALL BE 2 #12 AWG HIGH-FLEX COPPER CLAD STEEL CONDUCTOR (HF-CCS), INSULATED WITH A 30 MIL, HIGH DENSITY, HIGH MOLECULAR WEIGHT POLYETHYLENE (HDPE) INSULATION, AND RATED FOR DIRECT BURIAL USE AT 30 VOLTS. HF-CCS CONDUCTOR MUST BE A 21% CONDUCTIVITY FOR LOCATABILITY PURPOSES, RATED BREAK LOAD 282#. HDPE INSULATION SHALL BE RoHS COMPLIANT AND UTILIZE VIRGIN GRADE MATERIAL. INSULATION COLOR SHALL MEET THE APWA COLOR CODE STANDARD FOR IDENTIFICATION OF BURIED UTILITIES. 3.CONNECTORS SHALL BE COPPERHEAD SNAKEBITE LOCKING CONNECTORS OR PRE-APPROVED EQUAL. THESE CONNECTORS WILL NOT WORK WITH THHN PRODUCTS. 4.IF LOCATOR STATION IS TO BE PLACED AT A FIRE HYDRANT, PLACE IT DIRECTLY IN FRONT OF THE FIRE HYDRANT. SEE DETAIL 25 FOR LOCATOR STATION DETAILS. 5.GROUNDING RODS SHALL BE MAGNESIUM DRIVE IN ANODE WITH HDPE CAP AND 5' OF FACTORY INSTALLED 12 AWG COPPER CLAD STEEL WIRE WITH 30 MIL HIGH DENSITY, HIGH MOLECULAR WEIGHT POLYETHYLENE (HDPE) INSULATION, AND RATED FOR DIRECT BURIAL USE AT 30 VOLTS. HDPE INSULATION SHALL BE RoHS COMPLIANT AND UTILIZE VIRGIN GRADE MATERIAL. GROUNDED RODS TO BE AT ALL DEAD END POINTS OF THE TRACER WIRE. 6.TRACER WIRE FOR PERPENDICULAR MAINS AT STREET INTERSECTIONS ARE NOT TO BE SPLICED TOGETHER. 200 STANDARD INTERIOR SETTING FOR 3 4 IN. AND 1 IN. WATER METER GENERAL NOTES: NOT TO SCALE 201 TAP CONNECTION FOR CATHODICALLY PROTECTED MAIN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D3 SA N I T A R Y D E T A I L S 48 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 LOWER LIMIT OF TRENCH WALL SLOPING INITIAL LIFT * 12 IN. MIN. PIPE O.D. 4 IN. MIN. TRENCH WIDTH AS SPECIFIED IN SECTION 02221 COMPACTED GRANULAR MATERIAL CONFORMING TO CDDH #67 * DATE REVISED: APPROVED: DRAWN BY: BEDDING REQUIRMENTS WW-1 NBJ 4/11/11 ALTERNATE BASE POURED INVERT PRECAST MANHOLE BASE 2 I N . M I N . SLOPE 1 IN. MIN. 8 IN. MIN. 6 IN. 15 IN. OR LESS 48 IN. 60 IN.18 IN. TO 30 IN. 72 IN.OVER 30 INCHES MIN. MANHOLE MINIMUM INSIDE DIAMETER OF DIAMETER MANHOLE SHALL BE AS FOLLOWS: PIPE SIZE 5 F T . M I N . D E P T H CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE ASTM C-478 ECCENTRIC CONE PRE-FORMED PLASTIC GASKET ASTM C-478 MANHOLE SECTIONS GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET CAST-IN-PLACE CONCRETE BASE 16 IN. MAX. FINISHED GRADE 30 I N . M I N . 48 I N . M A X . VA R I A B L E 28 IN. MAX. 24 IN. SEE TABLE 6 IN. 12 IN. SLOPE 1 IN./FT. 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. 8 IN. MIN DATE REVISED: APPROVED: DRAWN BY: STANDARD MANHOLE WW-3 NBJ 4/11/11 PLAN VIEW CROSS VIEW 45 ELBOW SERVICE WYE 8 IN. PVC SEWER PIPE COMPACTED GRANULAR MATERIAL AIR-TIGHT PLUG WITH 4 IN. X 4 IN. MARKER UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR LEAN CONCRETE PVC SEWER PIPE NOTE: WYE CONNECTION NOT ALLOWED ON VCP LEAN CONCRETE o 20 MIN.o 45 MAX.o TRENCH UNYIELDING PIPE BEDDING OF COMPACTED ROCK OR 4 IN. X 4 IN. MARKER AIR-TIGHT PLUG DATE REVISED: APPROVED: DRAWN BY: SERVICE WYE DETAIL WW-9 NBJ 4/11/11 300 SEWER MAIN BEDDING REQUIREMENTS 304 SERVICE WYE DETAIL 301 STANDARD MANHOLE 302 FLAT-TOP MANHOLE POURED INVERT 1 IN. MIN. SLOPE PRECAST MANHOLE BASE ALTERNATE BASE 6 IN. 8 IN. MIN 8 IN. MIN. 2 IN. MIN. MIN. MANHOLEPIPE SIZE MANHOLE SHALL BE AS FOLLOWS: MINIMUM INSIDE DIAMETER OF OVER 30 INCHES 18 IN. TO 30 IN. 15 IN. OR LESS DIAMETER 72 IN. 60 IN. 48 IN. PRE-FORMED PLASTIC GASKET GROUT BASE TO BARREL SECTION ON INSIDE PRE-FORMED PLASTIC GASKET 12 IN. 6 IN. 5 FT. MAX. 1 IN./FT. SLOPE 18 IN. MAX. MANHOLE RUNGS 12 IN. O.C. AS NEEDED SEE TABLE FINISHED GRADE 16 IN. MAX. 28 IN. MAX. CAST-IN-PLACE CONCRETE BASE ASTM C-478 MANHOLE SECTIONS OF CONICAL TOP ASTM C-478 CONCRETE ADJUSTMENT SHIMS GROUTED INSIDE NOTE: IF MANHOLE DEPTH IS LESS THAN 3 FEET, TOP SECTION SHALL HAVE A CONCENTRIC OPENING. 2 IN. MIN. FLAT SLAB TOP SECTION IN LIEU DATE REVISED: APPROVED: DRAWN BY: FLAT-TOP MANHOLE WW-5 NBJ 4/11/11 NO. 3 BARS @ 3 FT. CENTERS CONTINUOUS NO. 4 BARS CONCRETE ENCASEMENT SEWER LINE NO. 3 BARS AT 3 FT. CENTERS CONTINUOS NO. 4 BARS WATER LINE 10 FT. MINIMUM10 FT. MINIMUM 6 IN. 6 IN. NOTE: CONCRETE ENCASEMENT WILL BE REQUIRED ON SEWER LINE WHEN CLEAR VERTICAL DISTANCE FROM WATER LINE IS LESS THAN 1 FT.-6 IN. OR HORIZONTAL DISTANCE IS LESS THAN 10 FT. BETWEEN PARALLEL LINES. CONCRETE ENCASEMENT REQUIRED IN ALL CASES WHERE SEWER LINE IS ABOVE WATER LINE OR IS UNDER A WATERWAY CROSSING. DATE REVISED: APPROVED: DRAWN BY: CONCRETE ENCASEMENT DETAIL WW-6 NBJ 4/11/11 303 CONCRETE ENCASEMENT DETAIL CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D4 DR A I N A G E D E T A I L S 49 APPROVED: DATE: DRAWN BY: 1/12/00 SKC 400 STORMWATER BEDDING REQUIREMENTS 403 CURB, GUTTER, AND SIDEWALK DETAILS 401 STANDARD MANHOLE 402 SHALLOW MANHOLE WITH FLAT TOP 404 METAL SIDEWALK CULVERT FOR VERT. CURB & GUTTER AND DETACHED SIDEWALK APPROVED: DATE: DRAWN BY: 11/7/00 NBJ APPROVED: DATE: DRAWN BY: 11/8/00 NBJ APPROVED: DATE: DRAWN BY: 11/13/00 NBJ APPROVED: DATE: DRAWN BY:D. MOGEN 7/30/2013 SECTION B-B DETAIL 1 SECTION A-A PLAN SECTION C-C CC BB A A PLAN VIEW SECTION A-A SECTION B-B GENERAL NOTES: B A A B DETAIL "A" APPROVED: DATE: DRAWN BY:NBJ 12/18/00 405 METAL SIDEWALK CULVERT FOR DRIVE-OVER CURB, GUTTER AND SIDEWALK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SECTION B-B DETAIL 1 SECTION A-A PLAN SECTION C-C CC BB A A Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D5 DR A I N A G E D E T A I L S 50 2' TOP OF WEIR WEIR CREST ELEV. 2'2'L2' 2-#5 BARS 1 4 (SEE NOTE) 8" MINIMUM THICKNESS 2-#5 BARS 1 4 3" C L R 3" C L R NOTE: TRENCH FOR WEIR OUTLET STRUCTURE USING NATIVE GROUND AS FORM WORK. CONSTRUCT WEIR 8" MINIMUM THICKNESS. UPON COMPLETION OF TRENCHING, PLACE TEMPERATURE STEEL AND CONCRETE IMMEDIATELY. FORM TOP 4". TOP OF BERM/EMBANKMENT 30" MIN. APPROVED: DATE: DRAWN BY: 12/22/00 NBJ GENERAL NOTES: 1. 6 IN. X 6 IN. X 10/10 WWF SHALL BE INSTALLED IN RADIUS AND PAN. 2. MINIMUM 6 IN. WIDE PAN FOR RESIDENTIAL STREET. 3. MINIMUM 10 FT. WIDE PAN FOR ARTERIAL AND COLLECTOR STREETS. 501 STREET INTERSECTION GUTTER DETAIL WITH CROSS PAN 502 CONCRETE END SECTIONS 505 4' SIDEWALK CULVERT APPROVED: DATE: DRAWN BY: 01/31/01 NBJ E C B E E C D PLAN 500 CONCRETE SIDEWALK CULVERT FOR DETACHED SIDEWALK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 506 WEIR DETAIL EMERGENCY OVERFLOW WEIR SUMMARY TABLE Pond No.Top of Weir Elevation (ft) Top of Bank Elevation (ft) Weir Crest Elevation (ft) Notch Width, W, ft Length, L (ft) 1 4987.20 4987.20 4986.20 75 4 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D6 DR A I N A G E D E T A I L S 51 CC A A B B SECTION C-C SECTION A-A SECTION B-B WELL SCREEN FLOW CONTROL PLATE PLAN GENERAL NOTES SECTION D-D D D A A ABBREVIATIONS LEGEND ORIFICE OPENING PLATE CENTERED OVER PIPE OPENING IN WALL 12" Ø HOLES FOR 3 8" Ø EXPANSION BOLTS EMBEDDING 2" INTO CONCRETE WALL @ 6" O.C. MIN. 5 16" THICK GALVANIZED STEEL PLATE D D+4" D+4" ORIFICE INVERT SHALL MATCH PIPE INVERT 601 ORIFICE PLATE (CONCRETE OUTLET STRUCTURE) Pond ID Orifice Opening Diameter (in.) Pond 1 12 604 OPEN CHANNEL DETAILS 602 WATER QUALITY OUTLET STRUCTURE 603 SMALL PIPE HEADWALL 605 CONCRETE TRICKLE PAN 600 4' CONCRETE PAN W/ CURB FG 6" or 7" SEE PLANS 2' 0.5' #4@6" O.C. #4L@12" O.C. 3" CL R . #4@12" O.C.#4L@12" O.C. 6" or 7" SEE PLANS APPROVED: DATE: DRAWN BY: 12/26/00 NBJ APPROVED: DATE: DRAWN BY:NBJ 12-25-00 N.T.S. 16" BE REFERENCED TO THE DEEPEST POINT OF THE POND. GAUGE SHALL BE PLACED NEAR THE DEEPEST AREA OF THE POND, IN CONCRETE WITH A DIMENSION OF 16"x14"x3' IN DEPTH. THE AND NUMBERS SHALL BE PAINTED WITH WHITE WATERPROOF SQUARE POSTS MEASURING 6"x8" WITH BOTH 8" SIDES ROUTED THE GAUGE SHALL BE CONSTRUCTED OF PRESSURE TREATED NOTE: 3' GROUND LEVEL CONCRETE 14" 6" 3 4 2 HE I G H T V A R I E S 1 8" APPROVED: DATE: DRAWN BY:TDC 2/18/05 606 DETENTION POND DEPTH GAUGE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 4' 4' 1' 4986.20 4982.97 4984.97 4985.97 0.65' 1/3" 1 3 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D7 DR A I N A G E D E T A I L S 52 700 BIORETENTION 701 BIORETENTION - UPTURNED ELBOW OUTFALL A A SECTION A-A PLAN VIEW DIRECTION OF FLOW COMPACTED NATIVE SOIL FLOWLINE OF NOTCH RAIN GARDEN FINISH GROUND 12" CURB HEIGHT 6.0" DIRECTION OF FLOW NOTE: 1.SEE GRADING PLAN FOR ELEVATIONS AND SLOPES. 1" NOTCH 6" TYP. VARIES (SEE PLAN) VA R I E S (S E E P L A N ) TYPE L RIPRAP OR RIVER ROCK PER PLANS PIPE OR RUNDOWN PIPE OR RUNDOWN TYPE L RIPRAP OR RIVER ROCK PER PLANS LIMITS OF RAIN GARDEN BIOMEDIA SOIL 702 CONCRETE FOREBAY CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D8 SI T E D E T A I L S 53 7 3/8" (L)1 3/8" 17 " 6" 3 3/8" 14 " FL R 16" R 16" DR I V E - O V E R C U R B , G U T T E R A N D D E T A C H E D S I D E W A L K 31 " Se e D r a w i n g 1 6 0 1 10 3/4"(L) R 16" DR I V E - O V E R C U R B , G U T T E R A N D A T T A C H E D S I D E W A L K 18 " 18 " 3 3/8" 1 3/8" 6" R 16" FL 14 " 6" 17 " 1 1 / 2 " 5' ( L ) 8 5/8" (F.C.) 7 1/4" F.C. 12" (F.C.) Sl o p e t o c u r b 1 / 4 " / F t . 1' m i n . ( F . C . ) 48 : 1 m i n . 4: 1 m a x . Ex c a v a t i o n Fi l l 1' m i n . 2' m i n . 1/ 4 " / F t . CU R B & G U T T E R I N A C U T O R F I L L 6" 3' - 9 " ( F . C . ) Fo r T h i c k n e s s 2' m i n . ( L ) Final asphalt lift, overlay or grade adjustment Depress ring 1/4" to 5/8" below adjacent finished street grade Slope up to match finished pavement Straight cut around ring Concrete grade ring to match slope or finished grade Grade ring Existing base course Manhole Shim / Grout 16 " m a x . NOTE: 1. Grout shall be a mixture of 100 lbs Grout mix, 26 lbs water (3.12 Gal), and 100 lbs of sand conforming to ASTM C-35. 2. Manholes shall not be located in crosspans, gutters, or wheel path. 3. Shim and grout to make ring and cover flush with the finished pavement surface. Cover Support with Steel Shims and pack with High Strength Grout Cross section of post SW SAMPLE AVE 2400 *12 Gauge CRITERIA FOR SINGLE POST Max. Sign Panel Telespar 22F12A O3PG Anchor Post * Telespar 20F12P-10PG Post * 36"x36"2.25"x2.25"x3'-0"2"x2"x12'-0" NOTES: 1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose from the post when hit by a vehicle. 2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground. 3. Signs larger than 36 inches in length or width require wind bracing and special post design. 4. Anchor Stub and post are square steel tube (perforated). 5. All "No Parking" signs shall be installed at 45° from Flow Line. 6. R1-1 "STOP" sign 30" High Density/Diamond Grade.Sign mounted to post with 1each drive rivet with nylon washer against sign face (on Top of the Sign). sign shall be mounted with 1 each 5/16"x2 1/2" Hew Bolt with nylon washers against sign face (on Bottom of the Sign). Secured with 1 each 5/16" Hex Nut on the back side of Post. 7. 4" Core Drill in Asphalt or Concrete or provide a 4" PVC sleeve cut flush to the surface for placement of anchor post. Voids to be filled in with sand or other fine suitable material. SW SAMPLE AVE 2400 ATTACHED SIDEWALK DETACHED SIDEWALK 8" 8" 30 " 7' - 0 " 3' (min.) BOC (m i n . ) C l e a r a n c e 3' 2 each 8" Blades mounted to Post with 4 each Drive Rivets with Nylon Washers 8" 30 " 7' - 0 " 1' 8" 3' 3" - 6" Above Grade (TYP) (m i n . ) C l e a r a n c e (min.) Telespar Post 4" - 6" Below Grade (TYP) Concrete or AsphaltSand or other fine suitable material Double Lines Normal Width Line 4" White 4" Yellow 4" Space 4" White Preferential lane symbol (6' X 4') for designated bikeways. White pavement marking placed 65' (min) from the projected flowline and Pr o j e c t e d F l o w l i n e ( F L ) NO CROSSPAN Continental bars (9' X 1.5'): NO C R O S S P A N O R E X I S T I N G C R O S S P A N White Stop Bar (1.5' X Length) 30' Gaps 3:1 Ratio 10' Segments 4" White Broken Line ST A N D A R D NO S T O P B A R S P E C I F I E D STOP BAR SPECIFIED STOP BAR SPECIFIED EXISTING CROSSPAN Crosspan exits (no stop bar) -- shall No crosspan -- shall be positioned along projected flowline. match the edge of the pan. Crosspan exits (stop bar specified) -- shall be positioned along projected flowline overlapping 4' of crosspan. 1 2 3 FL to stop bar 14.5' Projected 14.5' Stop Bar to FL 13 ' 9' 1.5' 6' Crosspan 4' 4' 4' NOTES: Continental crosswalk bars shall be placed centered on each lane line & in the center of each lane. (Lanes 5' wide or less shall not receive a bar centered in the lane.) Both outside Continental bars shall be centered on the curb & gutter when possible. If 6' crosspan exists, bars to match pan edge to 13' from projected FL. Exception: The downstream bike lane line shall terminate at the curb return. NOTE: All longitudinal (lane) striping shall terminate at the continental crosswalk bars when no stop bar exists. If a stop bar is specified, the striping shall terminate at the stop bar. 65' (min) centered on bike lane. PA V E M E N T D E S I G N + 1 / 2 " F O R C O L L E C T O R 8" M I N . F O R R E S I D E N T I A L . U S E C O N C R E T E 10 ' M I N I M U M ( A R T E R I A L ) 8' M I N I M U M ( C O L L E C T O R ) 6' M I N I M U M ( L O C A L ) CO L D J O I N T AT 1 0 ' O . C . TO O L J O I N T FO R P A N S O V E R 4 0 ' CO N T R O L J O I N T R E Q U I R E D CO N T R O L RO A D W A Y W I D T H AL L I N T E R S E C T I O N S T O HA V E A C C E S S R A M P S NO T E : ** & A R T E R I A L S . SI D E S . TO P A N S E C T I O N , T Y P I C A L B O T H TR A N S I T I O N F R O M C & G S E C T I O N WA L K 8' DO W E L L I F JO I N T S TO O L J O I N T JO I N T S ( T Y P . ) CO N T R O L Ar t e r i a l 10 ' 1 1 / 4 " 1 1 / 2 " Co l l e c t o r 8' 1" 1 1 / 8 " Lo c a l 6' 3/ 4 " 7/ 8 " 1 1 / 2 " 2 1 / 2 " 2" d 8' M I N . W I D T H W H E R E C R O S S I N G A C O L L E C T O R R O A D W A Y . ** ** LE N G T H (f o r m o n o l i t h i c p o u r ) THICKNESS ASPHALT DESIGNED 2T * W ASPHALT 2T * W T W P.C. CROSSPAN THICKENED ASPHALT THICKENED ASPHALT THICKNESS DESIGNED AND WALK CURB, GUTTER T = THICKNESS OF CROSSPAN W = WIDTH OF CROSSPAN P.C. *-If subgrade is flyash treated, use T instead of 2T. 800 CURB AND GUTTER/SIDEWALK 803 STANDARD MANHOLE COVER 801 STREET INTERSECTION CROSSPAN 802 ASPHALT PAVING DETAIL (CROSSPAN) 804 805SIGN POST STANDARD PAVEMENT MARKINGS PAVEMENT MARKINGS Projected Flowline (FL) Broken line 4" white 10' Segments 30' Gaps (3:1 Ratio) Wide Lane 1.5'x9' 8" White Line 4" white Double Line 4" Yellow 4" Space CROSSWALK MARKINGS: STRIPING: PREFERENTIAL LANE SYMBOL: STOP LINES: MANDATORY MOVEMENT: 1.5'x9 10 0 ' T a p e r ( m i n . ) .2L L = T u r n B a y S t o r a g e L e n g t h .4L 10' .4L 10' 4" Ywllow 4" White Extension Line An Engineering study should be required before crosswalk markings are installed in locations away from traffic signals or stop signs. Continental crosswalk bars (1.5' x 9' typ.) shall be placed adjacent to the projected flowline or abutting to existing crosspan. A bar shall be placed centered on each lane line and in the center of each lane. Lanes 5' wide or less shall not receive a bar centered in the lane. It is important that the markings are in alignment with the access ramps / sidewalks. On curves: Dotted extension of lane edge with same as solid downstream line, 2' segments, 4' gaps. Mandatory movement lanes shall use a lane-use arrow marking, the word marking "only", another lane-use arrow marking (accompanied by signs). Symbols & words are 8' of more in height -- use CDOT specification sizes. Place stop lines (1.5' x Variable typ.) only when inportant to indicate the point behind which vehicles are required to stop (more often on main arterials) -- placement should ordinarily be 4' in advance of and parallel to the nearest crosswalk line in the absence of a marked crosswalk, the stop line should be placed at the desired stopping point no more than 30' or less than 4' from the nearest edge of the intersecting roadway. PLS shall be used for designated bikeways. Intersection placement -- the symbol shall be placed downstream to convey to turning traffic that the bike lane exists. It shall be placed 4" down from the PCR & centered on the bike lane. Frequency of placement between blocks is a matter for Engineering judgement. All Longitudinal (lane) striping shall terminate at the Continental crosswalk bars -- except the downstream bike lane which shall terminate at the curb return. If a stop line is in place -- upstream stripping shall terminate at the stop line. Not Required with lane lengths less than 100'. Not Required with lane lengths less than 100'. 8" White Line 8" White Extension Line8" White Extension 4" White Line 65' (min) 4' Note: Two-Way Left-Turn Lane (TWLTL) Striping TWLTL striping is 4” yellow skip (10’ line, 30’ gap), 4” space, 4”solid yellow 806 STANDARD PAVEMENT MARKINGS W/ TURN LANE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 D9 SI T E D E T A I L S 54 ATTACHED SIDEWALK DETAIL Slope sidewalk to curb 1/4" per foot. NOTE: Construct sidewalk with joints at 10' intervals R 1/8" WEAKENED PLANE JOINT EXPANSION JOINT R1/4" and aligned with scoring on curb. INSTALL IN LOCATIONS SPECIFIED IN CHAPTER 22 1/2" 1/4" 1/4 SLAB THICKNESS 1/4" 1/2" Expansion Joint material DETACHED SIDEWALK DETAIL Variable Landscaping Slope sidewalk to curb 1/4" per foot. 2' min. Slope: Minumum 1 4"/ft Maximum 3"/ft FORT COLLINS ONLY No t e s : 1 . S e t r a m p s l o p e s u s i n g t h e c e n t e r o f t h e ra m p . 2 . T r u n c a t e d d o m e w a r n i n g p a n e l : I n s t a l l pa n e l s a l o n g w i t h t h e c o n c r e t e p o u r f o r t h e ra m p . S p e c i f i c a t i o n s f o r t h e p a n e l m a t e r i a l wi l l b e p r o v i d e d u p o n r e q u e s t . 3 . E a c h r a m p s h a l l a l i g n p e r p e n d i c u l a r t o t h e st r e e t i n w h i c h t h e r a m p i s p r o v i d e d t o cr o s s . 4 . R e f e r t o s t a n d a r d d r a w i n g 1 6 0 6 i n t h e La i m e r C o u n t y u r b a n a r e a s t r e e t s t a n d a r d s fo r o t h e r n e c e s s a r y c r i t e r i a n e e d e d t o co n s t r u c t t h e s e r a m p s t h a t i s n o t s p e c i f i e d on t h i s d r a w i n g . 5 . C o n s t r u c t t h e r a m p s a n d w a l k s o t h e c o r n e r ar e a a l l d r a i n s t o t h e s t r e e t . 6 . I f c u r b a n d g u t t e r a r e p o u r e d m o n o l i t h i c w i t h ra m p , p l a c e d o m e e d g e a t b a c k o f c u r b a s sh o w n . I f n o t p o u r e d m o n o l i t h i c , p l a c e do m e e d g e 6 " f r o m b a c k o f c u r b . PL A N V I E W NT S Ramp Fl a r e G u t t e r Ra m p Ra m p Fl a r e C u r b Cu r b Co n c . F l a r e Pa n e l s Pa n e l s Tr u n c a t e d d o m e pa n e l s : 1- 2 ' x 2 . 5 ' 1- 2 ' x 2 ' Tr u n c a t e d D o m e W a r n i n g De t e c t i o n P l a n L o c a t i o n s LE G E N D : BO C - B a c k o f c u r b ⅊ P r o p e r t y L i n e PT - P o i n t o f T a n g e n c y Flow line Se c t i o n A - A NT S 4' - 6 " 2' - 0 " 2' - 6 " 2' - 0 " t Varies Varies 4. 5 ' 6. 0 ' .5 ' 1. 5 ' 4. 5 ' 1. 5 ' 12 . 0 ' 12 . 0 ' 4. 5 ' .5 ' 6. 0 ' 4. 5 ' L a n d s c a p e d A r e a PT C u r b A A 6" C u r b (T Y P ) 0" C u r b Fu l l h e i g h t cu r b Tr u n c a t e d d o m e wa r n i n g d e t e c t i o n  ⅊ PT o f w a l k R1 5 . 0 ' ⅊ ⅊ & B O W 5' - 6 " B O C t o w a l k w / v e r t i c a l c u r b 5' - 7 " B O C t o w a l k w / d r i v e o v e r c u r b Co n c . S i d e w a l k Ar e a t o b e l a n d s c a p e d Co n c . w a l k Gu t t e r or Ap r o n Tr u n c a t e D o m e Wa r n i n g P a n e l 1 : 1 2 M a x s l o p e 1 : 2 0 S l o p e PT o f c u r b re t u r n 6" Co n c . F l a r e 6" C u r b (T Y P ) See note 6 900 FHWA ARROWS (ELONGATED)901 SIDEWALK DETAIL 902 RESIDENTIAL LOCAL STREET ACCESS RAMPS 903 TRENCH DETAIL 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials Pa v e m e n t Th i c k n e s s Va r i e s Va r i e s 1" ( m i n . ) (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R T IR W WWW W S S W T T ELEC S S M W W T S MM W M H Y D FO FO FO XXXX G G OHU OHU FO FO W W W W W W W W W W W W W W W W W W W WFOFOFO X X G G G FO FO FO F O W G G G G G G G X X X X X X X X X X X X X X FO FO FO FO FO OHU OHU OHU OHU O H U OHU OHU OHU OHU W W W FO FO FO FO X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX X X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FO FO FO FO FO G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FOFO G E E E E E E E E E E E W W W W W W OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU O H U O H U O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU WWWWWWWWW W W W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF ACKELSON CONNIE A. 603 W WILLOX LANE, KAFKA, AMY 709 W WILLOX LANE, SA I N T TH E R E S E ST R E E T SAI N T JOS E P H STR E E T WEST WILLOX LANE S A I N T J E R O M E S T R E E T EC1 ER O S I O N C O N T R O L P L A N 55 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 MATCH LINE - SEE SHEET EC2 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET EC1 EC2 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY BENCHMARK/BASIS OF BEARING: SILT FENCE ROCK SOCK 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2.SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4.REFER TO THE Final Drainage Report dated April 12, 2024 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. GENERAL NOTES: WATTLE DIKE CONCRETE WASH AREA LEGEND: BALE OUTLET PROTECTION INLET PROTECTION VEHICLE TRACKING CONTROL PAD SF BENCHMARK: #1 City of Fort Collins Benchmark NO. 9-07. Elevation=4999.15 BENCHMARK: #2 NGS Benchmark V-401. Elevation=4977.81 Basis of Bearings Assuming the North line of the Northeast Quarter of the Northwest Quarter of Section 2, Township, 7 North, Range 69 West of the 6th P.M., as bearing North 89°33'13" East. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: WILLOX FARMS CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) STRUCTURAL "INSTALLATION" Silt Fence Barriers * Straw Wattles * Inlet Protection * Vegetative Temporary Seeding Planting Mulching / Sealant Permanent Seeding Planting Sod Installation Rolled Products : Netting / Blankets / Mats Concrete Washout Area* Rock Socks * UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Vehicle Tracking Pad * * All Temporary BMPs to be Removed once Construction is Complete Any prior inlets that could use protecting Any prior inlets that could use protecting Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days UD UD UD U D U D UD UD UD W W T W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX X X X X SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSF SF PITT, JEAN 1522 WOOD LANE, GBP LLC 1434 WOOD LANE, PEREZ DANIEL A. 400 HICKORY STREET 149 PEREZ DANIEL A. 400 HICKORY STREET 149 SA I N T JE R O M E ST R E E T MOLLER STREET SAINT GRACE STREET SOFT GOLD PARK EC2 ER O S I O N C O N T R O L P L A N 56 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 MATCH LINE - SEE SHEET EC1 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET EC1 EC2 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY BENCHMARK/BASIS OF BEARING: SILT FENCE ROCK SOCK 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2.SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4.REFER TO THE Final Drainage Report dated April 12, 2024 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. GENERAL NOTES: WATTLE DIKE CONCRETE WASH AREA LEGEND: BALE OUTLET PROTECTION INLET PROTECTION VEHICLE TRACKING CONTROL PAD SF BENCHMARK: #1 City of Fort Collins Benchmark NO. 9-07. Elevation=4999.15 BENCHMARK: #2 NGS Benchmark V-401. Elevation=4977.81 Basis of Bearings Assuming the North line of the Northeast Quarter of the Northwest Quarter of Section 2, Township, 7 North, Range 69 West of the 6th P.M., as bearing North 89°33'13" East. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: WILLOX FARMS CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) STRUCTURAL "INSTALLATION" Silt Fence Barriers * Straw Wattles * Inlet Protection * Vegetative Temporary Seeding Planting Mulching / Sealant Permanent Seeding Planting Sod Installation Rolled Products : Netting / Blankets / Mats Concrete Washout Area* Rock Socks * UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Vehicle Tracking Pad * * All Temporary BMPs to be Removed once Construction is Complete Any prior inlets that could use protecting Any prior inlets that could use protecting Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days Anytime the site will sit dormant longer than 30 Days EC3 ER O S I O N C O N T R O L D E T A I L S 57 VTC ROCK SOCK SECTION ROCK SOCK PLAN ROCK SOCK JOINTING GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2"100 1-1/2"90-100 1"20-55 3/4"0-15 3/8"0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES RS 001 CONCRETE WASHOUT AREA 002 ROCK SOCK 003 VEHICLE TRACKING PAD 004 SILT FENCE SF CWA 005 CURB INLET PROTECTION IP POSTS PREASSEMBLED SILT FENCE POSTS SHALL OVERLAP AT JOINTS SO THAT NO GAPS EXIST IN SILT FENCE. NOTE: THICKNESS OF GEOTEXTILE HAS BEEN EXAGGERATED.POST SHALL BE JOINED AS SHOWN, THEN ROTATED 180° IN DIRECTION SHOWN AND DRIVEN INTO THE GROUND. SILT FENCE JOINTS DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18". EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES, ETC. SHALL BE USED. NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE BURIED IN THE TRENCH. THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND. SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY. INSTALLATION NOTES: 1. 2. 3. 4. 5. 6. 7. THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6". SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. MAINTENANCE NOTES: 1. 2. 3. 4" MIN. 4" MIN. 1 12" x 1 12" WOODEN FENCE POSTS SF 006 SWALE WATTLE DIKE Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R OUTLET PROTECTION AA PLAN VIEW SECTION A-A 2:1 OP WQCV 007 W WWW W W W T W S S W T ELECS S T MS W W WM W W T S MM W M H Y D MM M M FO FO FO FO XXXXXXX G G G G G OHU OHU OHU OHU FO FO FO FO W W X X W W W W W W W W W W W W W W FO FO X G G FO FOGG G G G G X X X X X X X X X X X X X X X X X X X X X FO FO FO OHU OHU OHU OHU OHU OHU O H U OHU OHU OHU OHU OHU OHU OHU W W W W W W W G O H U OHU FO FO FO FO FO FO FO FO OHU XG X X X X X X X X X X X X X X X X X X X X X X X X X XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FO FO FO FO FO FO FO FO FOGGGGGGGGG FO FO FO FO FO FO FO FOFO E E E E E E E W W W W X X X OHU O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU X X X XX X W W W W W W W W W W W W W W W W 19.01 ac. 1 1 WEST WILLOW LANE EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED WITH PLAT (ENCROACHES ON PROPERTY. SEE PLAT FOR NOTES) EXISTING 10' UTILITY EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT EXISTING 10' MOUNTAIN STATES UTILITY EASEMENT EXISTING 30' NCWA EASEMENT EXISTING 6' CITY OF FORT COLLINS EASEMENT 100' UNION PACIFIC RAILROAD ROW PROPERTY BOUNDARY PROPERTY BOUNDARY PROPERTY BOUNDARY PROPERTY BOUNDARY EXISTING 20' PUBLIC DRAINAGE EASEMENT TO BE CONVERTED TO PUBLIC EASEMENT ACKELSON CONNIE A. 603 W WILLOX LANE, KAFKA, AMY 709 W WILLOX LANE, PITT, JEAN 1522 WOOD LANE, GBP LLC 1434 WOOD LANE, PEREZ DANIEL A. 400 HICKORY STREET 149 PEREZ DANIEL A. 400 HICKORY STREET 149 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 NORTH ( IN FEET ) 0 1 INCH = 60 FEET 60 60 120 180 DR1 HI S T O R I C D R A I N A G E E X H I B I T 58 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: A LEGEND: 1.REFER TO THE FINAL DRAINAGE REPORT DATED APRIL 12, 2024 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. DR1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R HISTORIC DRAINAGE SUMMARY Design Point Basin ID Total Area (acres)C2 C100 2-Yr Tc (min) 100-Yr Tc (min) Q2 (cfs) Q100 (cfs) 1 Project Area A 19.014 0.25 0.31 18.4 18.4 8.08 34.90 / / / / / / / / / / / / / / / / / / / / / / / / W WWW W S W T ELEC S S T MS W W WM W W T S MM W XXXXX X XXXXXX XOHU OHU OHU OHU OHU OHU OHU X XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX X X X X X X X X X X X X X X X E E E E E E E E E E E OHU O H U O H U O H U O H U OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU WWWWWWWWWWWWWWW W W W W W W W W W W W T A3A3 A1A1 SA I N T T H E R E S E S T R E E T SAINT JOSEPH STREET WILLOX LN ACKELSON CONNIE A. KAFKA, AMY PROPERTY BOUNDARY PROPERTY BOUNDARY PROPERTY BOUNDARY S A I N T J E R O M E S T R E E T 3.51 A7 1.74 ac. A5 0.86 ac. A8 0.56 ac. A9 2.36 ac. B1 3.92 ac. OS1 0.53 ac. OS2 0.07 ac. OS3 0.17 ac. OS4 1.17 ac. A6 PROPOSED 4' SIDEWALK CHASE PROPOSED 4' SIDEWALK CULVERT PROPOSED 4' CONCRETE PAN w/ CURB PROPOSED 2' SIDEWALK CHASE PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN 0.33 ac. OS5 WILLOX STORM DRAIN SEE SHEET ST3 WILLOX EAST STORM DRAIN SEE SHEET ST4 1.34 ac. OS7 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 DR2 DE V E L O P E D D R A I N A G E E X H I B I T 59 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 1.REFER TO THE "FINAL DRAINAGE REPORT DATED APRIL 12, 2024" BY NORTHERN ENGINEERING DATED FOR ADDITIONAL INFORMATION. 2.THE WILLOX FARM PROJECT WILL BE DETAINING THE DIFFERENCE BETWEEN THE HISTORIC 2-YEAR EVENT AND THE DEVELOPED 100-YEAR EVENT. 3.LID MEASURES IS PROVIDED VIA RAIN GARDEN. 4.ALL PROPOSED STORM SEWER ARE TO BE PRIVATELY OWNED AND MAINTAINED. SWALE SECTIONS PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: A LEGEND: MATCH LINE - SEE SHEET DR3 DR2 DR3 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R DEVELOPED DRAINAGE SUMMARY Design Point Basin ID Total Area (acres) C2 C100 2-Yr Tc (min) 100-Yr Tc (min) Q2 (cfs) Q100 (cfs) A a1 A1 0.71 0.55 0.69 5.00 5.00 1.12 4.87 a2 A2 2.33 0.62 0.77 10.06 10.06 3.19 15.11 a3 A3 0.60 0.46 0.58 9.72 9.72 0.62 2.89 a4 A4 0.20 0.42 0.52 9.46 9.46 0.19 0.85 a5 A5 1.71 0.35 0.44 11.39 11.39 1.28 5.66 a6 A6 1.18 0.39 0.49 12.52 12.52 0.94 4.31 a7 A7 3.52 0.63 0.79 11.54 11.54 4.65 21.47 a8 A8 0.86 0.28 0.35 9.33 9.33 0.56 2.50 a9 A9 0.56 0.73 0.91 6.10 6.10 1.09 5.06 b1 B1 2.36 0.28 0.35 13.49 13.49 1.31 5.71 b2 B2 1.10 0.67 0.84 8.14 8.14 1.77 8.35 b3 B3 0.75 0.45 0.56 8.51 8.51 0.79 3.62 Offsite Basins os1 OS1 3.92 0.20 0.20 13.06 13.06 1.55 5.43 os2 OS2 0.53 0.54 0.54 12.27 12.27 0.59 2.05 os3 OS3 0.07 0.78 0.78 5.00 5.00 0.16 0.56 os4 OS4 0.17 0.58 0.58 5.00 5.00 0.27 0.96 os5 OS5 0.33 0.20 0.20 6.87 6.87 0.17 0.60 os6 OS6 0.19 0.23 0.23 5.28 5.28 0.13 0.44 os7 OS7 1.34 0.20 0.20 11.39 11.39 0.58 2.03 SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 POND SUMMARY TABLE Pond ID Tributary Area (ac) Avg. Percent Imperviousness (%) Extended Detention WQCV (ac-ft) 100-Yr Detention Vol. (ac-ft) 100-Yr Detention WSEL (ft) Peak Release (cfs) Detention Pond 15.89 42 0.01 1.92 4,986.12 6.60 W W T W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX X UD UD UD U D U D UD UD UD A 2 A 2 A3A3 SA I N T J E R O M E S T R E E T MOLLER STREET SAINT GRACE STREET PITT, JEAN GBP LLC PEREZ DANIEL A. PEREZ DANIEL A. SOFT GOLD PARK PROPOSED DETENTION POND 100-YR DETENTION VOLUME = 1.91 AC-FT 100-YR WSEL= 4989.11 PROPERTY BOUNDARY PROPERTY BOUNDARY A4A4 2.31 ac. A 0.71 ac. A1 2.33 ac. A2 0.61 ac. A3 1.10 ac. B2 1.74 ac. A5 0.77 ac. B3 0.20 ac. A4 PROPOSED 2' SIDEWALK CHASE PROPOSED POND OUTLET STRUCTURE PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' SIDEWALK CHASE RAIN GARDEN B BIOMEDIA AREA RAIN GARDEN A BIOMEDIA AREA 0.19 ac. OS6 INLET A6 INLET A5 STORM DRAIN A SEE SHEET ST1 STORM DRAIN C SEE SHEET STORM DRAIN B SEE SHEETST2 RG B UNDERDRAIN RG A UNDERDRAIN STORM DRAIN C SEE SHEETST2 KEYMAP T C.O. WEST WILLOX LANE SOFT GOLD PARK HICKORY STREET Sheet WI L L O X F A R M Th e s e d r a w i n g s a r e i n s t r u m e n t s of s e r v i c e p r o v i d e d b y N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . a n d a r e no t t o b e u s e d f o r a n y t y p e o f co n s t r u c t i o n u n l e s s s i g n e d a n d se a l e d b y a P r o f e s s i o n a l E n g i n e e r in t h e e m p l o y o f N o r t h e r n En g i n e e r i n g S e r v i c e s , I n c . N O T F O R C O N S T R U C T I O N R E V I E W S E T of 60 FO R T C O L L I N S | G R E E L E Y | M E S A | G O O D Y E A R | T U C S O N | N O R T H P H O E N I X | F O R T W O R T H no r t h e r n e n g i n e e r i n g . c o m 97 0 . 2 2 1 . 4 1 5 8 DR3 DE V E L O P E D D R A I N A G E E X H I B I T 60 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 1.REFER TO THE "FINAL DRAINAGE REPORT DATED APRIL 12, 2024" BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. 2.THE WILLOX FARM PROJECT WILL BE DETAINING THE DIFFERENCE BETWEEN THE HISTORIC 2-YEAR EVENT AND THE DEVELOPED 100-YEAR EVENT. 3.LID MEASURES IS PROVIDED VIA RAIN GARDEN. 4.ALL PROPOSED STORM SEWER ARE TO BE PRIVATELY OWNED AND MAINTAINED. PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: A LEGEND: MATCH LINE - SEE SHEET DR2 DR3 DR2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SWALE SECTIONS SWALE SUMMARY TABLE SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q Q*1.33 A1 - A1 0.63 26.41 13.0 2.0 27.0 8.1 10.77 A2 - A2 0.96 22.11 10.7 4.0 16.7 39.0 51.87 A3 - A3 0.78 4.90 144.0 4.0 6.0 7.8 10.37 POND SUMMARY TABLE Pond ID Tributary Area (ac) Avg. Percent Imperviousness (%) Extended Detention WQCV (ac-ft) 100-Yr Detention Vol. (ac-ft) 100-Yr Detention WSEL (ft) Peak Release (cfs) Detention Pond 15.89 42 0.01 1.92 4,986.12 6.60 DEVELOPED DRAINAGE SUMMARY Design Point Basin ID Total Area (acres) C2 C100 2-Yr Tc (min) 100-Yr Tc (min) Q2 (cfs) Q100 (cfs) A a1 A1 0.71 0.55 0.69 5.00 5.00 1.12 4.87 a2 A2 2.33 0.62 0.77 10.06 10.06 3.19 15.11 a3 A3 0.60 0.46 0.58 9.72 9.72 0.62 2.89 a4 A4 0.20 0.42 0.52 9.46 9.46 0.19 0.85 a5 A5 1.71 0.35 0.44 11.39 11.39 1.28 5.66 a6 A6 1.18 0.39 0.49 12.52 12.52 0.94 4.31 a7 A7 3.52 0.63 0.79 11.54 11.54 4.65 21.47 a8 A8 0.86 0.28 0.35 9.33 9.33 0.56 2.50 a9 A9 0.56 0.73 0.91 6.10 6.10 1.09 5.06 b1 B1 2.36 0.28 0.35 13.49 13.49 1.31 5.71 b2 B2 1.10 0.67 0.84 8.14 8.14 1.77 8.35 b3 B3 0.75 0.45 0.56 8.51 8.51 0.79 3.62 Offsite Basins os1 OS1 3.92 0.20 0.20 13.06 13.06 1.55 5.43 os2 OS2 0.53 0.54 0.54 12.27 12.27 0.59 2.05 os3 OS3 0.07 0.78 0.78 5.00 5.00 0.16 0.56 os4 OS4 0.17 0.58 0.58 5.00 5.00 0.27 0.96 os5 OS5 0.33 0.20 0.20 6.87 6.87 0.17 0.60 os6 OS6 0.19 0.23 0.23 5.28 5.28 0.13 0.44 os7 OS7 1.34 0.20 0.20 11.39 11.39 0.58 2.03