Loading...
HomeMy WebLinkAboutUNION PARK - FDP240004 - SUBMITTAL DOCUMENTS - ROUND 1 - Electrical PlansM M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 200/2 PANEL "UNIT" 200/2 PANEL "HPL1" T F 800/3 800A 800/3 800A 200F3 200F3 100F4 1200S4 1 2 3 44 10 0 / 3 M N G 120/208V, 3PH, 4W PAD MOUNTED TRANSFORMER "MSB" 1200A, 120/208V, 3PH, 4W, NEMA 3R, 100kAIC TYPICAL UNIT PANEL (QTY 16) TYPICAL UNIT PANEL (QTY 16) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 3. PV CONNECTION BY PV CONTRACTOR. 4. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 5. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # 1 1 TO UTILITY PRIMARY PV PANEL / ARRAY 2 3 4 5 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 32 UNIT E500 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - U.P. APARTMENTS - 32 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 1200A 4/0BJ 8BJ 6GEC 3/0GEC 4GEC 3/0GEC 3/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 1200 1200S4 4 2 1/2" (4)350 KCM N/A 1200 1200S4 4 3 1/2" (4)500 KCM N/A 1200 1200F4 4 2 1/2" (4)350 KCM (1)#3/0 1200 1200F4 4 3 1/2"(4)500 KCM (1)250 KCM AL 800 800F4 3 3" (4)400 KCM (1)#1/0 800 800F4 4 3" (4)350 KCM (1)#3/0 AL 100 100F4 1 1 1/2" (4)#1/0 (1)#8 100 100F4 1 1 1/2" (4)#3/0 (1)#4 AL 90 90F4 1 1 1/2" (4)#1/0 (1)#8 80 80F4 1 1 1/4" (4)#1 (1)#8 70 70F4 1 1 1/4" (4)#2 (1)#8 60 60F4 1 1 1/4" (4)#3 (1)#10 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE MINIMUM SERVICE SIZE 425472 1181 HOUSE LOAD (VA)28880 28880 80 DWELLING UNIT DEMAND 396592 1101 DEMAND FACTOR 0.31 TOTAL DWELLING UNIT LOAD 1279328 VA AMPS TOTAL 32 1119584 159744 UNIT C1 2 34156 68312 4992 9984 UNIT C 2 36655 73310 4992 9984 UNIT B2 6 35692 214152 4992 29952 UNIT B1 2 34156 68312 4992 9984 UNIT B 2 36073 72146 4992 9984 UNIT A3 2 34156 68312 4992 9984 UNIT A2 6 34456 206736 4992 29952 UNIT A1 6 34480 206880 4992 29952 UNIT A 4 35356 141424 4992 19968 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 208Y/120, 3PH SERVICE CALCULATION FOR 32 UNIT MINIMUM SERVICE SIZE 280202 778 HOUSE LOAD (VA)28880 28880 80 DWELLING UNIT DEMAND 251322 698 DEMAND FACTOR 0.39 TOTAL DWELLING UNIT LOAD 644416 VA AMPS TOTAL 16 564544 79872 UNIT C1 2 34156 68312 4992 9984 UNIT C 2 36655 73310 4992 9984 UNIT B2 6 35692 214152 4992 29952 UNIT B1 2 34156 68312 4992 9984 UNIT B 2 36073 72146 4992 9984 UNIT A3 2 34156 68312 4992 9984 UNIT A2 UNIT A1 UNIT A QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 208Y/120, 3PH FEEDER CALCULATION FOR RIGHT METERS MINIMUM SERVICE SIZE 247616 687 HOUSE LOAD (VA) DWELLING UNIT DEMAND 247616 687 DEMAND FACTOR 0.39 TOTAL DWELLING UNIT LOAD 634912 VA AMPS TOTAL 16 555040 79872 UNIT C1 UNIT C UNIT B2 UNIT B1 UNIT B UNIT A3 UNIT A2 6 34456 206736 4992 29952 UNIT A1 6 34480 206880 4992 29952 UNIT A 4 35356 141424 4992 19968 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 208Y/120, 3PH FEEDER CALCULATION FOR LEFT METERS M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M PANEL "UNIT" 200/2 PANEL "UNIT" 200/2 PANEL "HPL1" T F 1200/3 1200A 1200/3 1200A 400F4 2000S4 1 2 3 44 M M M M M M M M M M M M M M M 200F3 M M M M M 200F3 10 0 / 3 M N G 120/208V, 3PH, 4W PAD MOUNTED TRANSFORMER "MSB" 2000A, 120/208V, 3PH, 4W, NEMA 3R, 100kAIC TYPICAL UNIT PANEL (QTY 19) TYPICAL UNIT PANEL (QTY 30) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS OR EQUAL. 2. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 3. PV CONNECTION BY PV CONTRACTOR. 4. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 5. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # 1 1 TO UTILITY PRIMARY 320A IN-LINE METER FOR HOUSE PANEL RATED AT 80%, 400A PV PANEL / ARRAY 2 3 4 5 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 49 UNIT E501 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - U.P. APARTMENTS - 49 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 2000A 300BJ 8BJ 6GEC 3/0GEC 4GEC 3/0GEC 3/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S4' RATHER THAN AN 'F4' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16 NOTES: 2000 200S4 6 3" (4)400 KCM N/A 2000 2000S4 8 3" (4)350 KCM N/A 2000 2000F4 6 3" (4)400 KCM (1)250 KCM 2000 2000F4 8 3" (4)350 KCM (1)400 KCM AL 1200 1200F4 4 3" (4)500 KCM (1)#3/0 1200 1200F4 5 3 1/2" (4)500 KCM (1)250 KCM AL 400 400F4 2 2 1/2" (4)250 KCM (1)#3 400 400F4 2 3" (4)350 KCM (1)#1 AL 100 100F4 1 1 1/2" (4)#1/0 (1)#8 100 100F4 1 1 1/2" (4)#3/0 (1)#4 AL 90 90F4 1 1 1/2" (4)#1/0 (1)#8 80 80F4 1 1 1/4" (4)#1 (1)#8 70 70F4 1 1 1/4" (4)#2 (1)#8 60 60F4 1 1 1/4" (4)#3 (1)#10 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 4-WIRE FEEDER SCHEDULE MINIMUM SERVICE SIZE 633525 1759 HOUSE LOAD (VA)115520 115520 321 DWELLING UNIT DEMAND 518005 1438 DEMAND FACTOR 0.26 TOTAL DWELLING UNIT LOAD 1992328 VA AMPS TOTAL 49 1747720 244608 UNIT D1 6 36613 219678 4992 29952 UNIT C3 3 36289 108867 4992 14976 UNIT C2 10 36130 361300 4992 49920 UNIT C1 6 36037 216222 4992 29952 UNIT A2 2 34864 69728 4992 9984 UNIT A1 19 35182 668458 4992 94848 UNIT S1 3 34489 103467 4992 14976 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 208Y/120, 3PH SERVICE CALCULATION FOR 49 UNIT BUILDING MINIMUM SERVICE SIZE 405576 1126 HOUSE LOAD (VA)115520 115520 321 DWELLING UNIT DEMAND 290056 805 DEMAND FACTOR 0.38 TOTAL DWELLING UNIT LOAD 763306 VA AMPS TOTAL 19 668458 94848 UNIT D1 UNIT C3 UNIT C2 UNIT C1 UNIT A2 UNIT A1 19 35182 668458 4992 94848 UNIT S1 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 208Y/120, 3PH FEEDER CALCULATION FOR RIGHT METERS MINIMUM SERVICE SIZE 405577 1126 HOUSE LOAD (VA) DWELLING UNIT DEMAND 405577 1126 DEMAND FACTOR 0.33 TOTAL DWELLING UNIT LOAD 1229022 VA AMPS TOTAL 30 1079262 149760 UNIT D1 6 36613 219678 4992 29952 UNIT C3 3 36289 108867 4992 14976 UNIT C2 10 36130 361300 4992 49920 UNIT C1 6 36037 216222 4992 29952 UNIT A2 2 34864 69728 4992 9984 UNIT A1 UNIT S1 3 34489 103467 4992 14976 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 208Y/120, 3PH FEEDER CALCULATION FOR LEFT METERS M M M M M PANEL "UNIT" 150/2 PANEL "HPL1" T F 150F3 60F3 1 2 3 4 600S3 600/2 600A 400S3 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 4) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS OR EQUIVALENT. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. MAIN FUSES SHALL ALSO BE REDUCED TO 400A WITHOUT A HOUSE PANEL. # TO UTILITY PRIMARY 1 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "ZIEGLER, 4-UNIT METER STACK" 600A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC IF NO HOUSE PANEL PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - ZIEGLER E502 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - ZIEGLER - 4 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - 400A 1/0BJ 8BJ 6GEC 1/0GEC 4GEC 1/0GEC 1/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 600 600F3 2 2 1/2" (3)350 KCM (1)#1 600 600F3 2 3 1/2" (3)500 KCM (1)#2/0 AL 400 400S3 2 2" (3)#3/0 N/A 400 400S3 2 2 1/2" (3)250 KCM N/A 400 400F3 2 2" (3)#3/0 (1)#3 400 400F3 2 2 1/2" (3)250 KCM (1)#1 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE REQUIRED FEEDER AMPACITY 133 104 TOTAL DEMAND (W)31991 24891 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19898.8 REMAINDER AT 40%24747 9898.8 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34747 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4256.85 REMAINDER AT 25% 3001 - 120000 VA 35% 3591 1256.85 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6591 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 2091 2091 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 697 SQFT UNIT ONE BED DWELLING UNIT LOAD CALCULATION MINIMUM SERVICE SIZE 83530 348 HOUSE LOAD (VA)12000 12000 50 DWELLING UNIT DEMAND 71530 298 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 158956 VA AMPS TOTAL 4 138988 19968 UNIT ONE BED 4 34747 138988 4992 19968 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 120/240, 1PH FEEDER CALCULATION FOR ZIEGLER 4 UNIT MINIMUM SERVICE SIZE 71530 298 HOUSE LOAD (VA) DWELLING UNIT DEMAND 71530 298 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 158956 VA AMPS TOTAL 4 138988 19968 UNIT ONE BED 4 34747 138988 4992 19968 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE 120/240, 1PH FEEDER CALCULATION FOR ZIEGLER 4 UNIT NO HOUSE PANEL M M M PANEL "UNIT" T F 600/2 600A 600S3 1 2 4 M 200/2 200F3 PANEL "HPL1" 60F3 3 M 10 0 / 3 M N G 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "BROWN 4-UNIT METER STACK" 600A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC TYPICAL UNIT PANEL (QTY 4) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # 1 TO UTILITY PRIMARY 2 PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - BROWN - 4 UNIT E503 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - BROWN - 4 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 700 700F3 2 3" (3)500 KCM (1)#1/0 700 700F3 3 3" (3)350 KCM (1)#3/0 AL 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE MINIMUM SERVICE SIZE 90189 376 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 78669 328 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 174820 VA AMPS TOTAL 4 154852 19968 UNIT C 1 37882 37882 4992 4992 UNIT B 1 39298 39298 4992 4992 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 4-UNIT MINIMUM SERVICE SIZE 78669 328 HOUSE LOAD (VA) DWELLING UNIT DEMAND 78669 328 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 174820 VA AMPS TOTAL 4 154852 19968 UNIT C 1 37882 37882 4992 4992 UNIT B 1 39298 39298 4992 4992 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 4-UNIT NO HOUSE PANEL M M M PANEL "UNIT" 200/2 T F 200F3 600S3 1 2 4 M M 600/2 600A PANEL "HPL1" 60F3 3 M 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 5) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # 1 TO UTILITY PRIMARY 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "BROWN 5-UNIT METER STACK" 600A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC 2 PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - BROWN - 5 UNIT E504 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 700 700F3 2 3" (3)500 KCM (1)#1/0 700 700F3 3 3" (3)350 KCM (1)#3/0 AL 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE SCALE: NO SCALE1ELECTRICAL ONE-LINE - BROWN - 5 UNIT MINIMUM SERVICE SIZE 110120 459 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 98600 411 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 219110 VA AMPS TOTAL 5 194150 24960 UNIT C 1 37882 37882 4992 4992 UNIT B 2 39298 78596 4992 9984 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 5-UNIT MINIMUM SERVICE SIZE 98600 411 HOUSE LOAD (VA) DWELLING UNIT DEMAND 98600 411 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 219110 VA AMPS TOTAL 5 194150 24960 UNIT C 1 37882 37882 4992 4992 UNIT B 2 39298 78596 4992 9984 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 5-UNIT NO HOUSE PANEL M M M PANEL "UNIT" T F 800S3 1 2 4 M M M 800/2 800A 200/2 200F3 PANEL "HPL1" 60F3 3 M 600S3 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 6) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. MAIN FUSES SHALL ALSO BE REDUCED TO 600A WITHOUT A HOUSE PANEL. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # TO UTILITY PRIMARY 1 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "BROWN 6-UNIT METER STACK" 800A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC 2 IF NO HOUSE PANEL PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - BROWN - 6 UNIT E505 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - BROWN - 6 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 800A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 800 800S3 3 2 1/2" (3)300 KCM N/A 800 800S3 3 3" (3)400 KCM N/A 800 800F3 3 2 1/2" (3)300 KCM (1)#1/0 800 800F3 3 3" (3)400 KCM (1)#3/0 AL 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 600 600F3 2 2 1/2" (3)350 KCM (1)#1 600 600F3 2 3 1/2" (3)500 KCM (1)#2/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE MINIMUM SERVICE SIZE 126793 528 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 115273 480 DEMAND FACTOR 0.44 TOTAL DWELLING UNIT LOAD 261984 VA AMPS TOTAL 6 232032 29952 UNIT C 2 37882 75764 4992 9984 UNIT B 2 39298 78596 4992 9984 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 6-UNIT MINIMUM SERVICE SIZE 115273 480 HOUSE LOAD (VA) DWELLING UNIT DEMAND 115273 480 DEMAND FACTOR 0.44 TOTAL DWELLING UNIT LOAD 261984 VA AMPS TOTAL 6 232032 29952 UNIT C 2 37882 75764 4992 9984 UNIT B 2 39298 78596 4992 9984 UNIT A 2 38836 77672 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH SERVICE CALCULATION FOR 6-UNIT NO HOUSE PANEL M M M PANEL "UNIT" 200/2 PANEL "HPL1" T F 200F3 60F3 600S3 1 2 3 4 M M 600/2 600A 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 5) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # 1 TO UTILITY PRIMARY 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "3STRY, 4-UNIT METER STACK" 600A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:18 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 3 STORY WALK-UP - 4 UNIT E506 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - 3 STORY TOWNHOME - 4 UNIT ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 600 600F3 2 2 1/2" (3)350 KCM (1)#1 600 600F3 2 3 1/2" (3)500 KCM (1)#2/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE MINIMUM SERVICE SIZE 89654 374 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 78134 326 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 173632 VA AMPS TOTAL 4 153664 19968 UNIT D 1 38584 38584 4992 4992 UNIT C 1 38140 38140 4992 4992 UNIT B 1 38140 38140 4992 4992 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 4-UNIT MINIMUM SERVICE SIZE 78134 326 HOUSE LOAD (VA) DWELLING UNIT DEMAND 78134 326 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 173632 VA AMPS TOTAL 4 153664 19968 UNIT D 1 38584 38584 4992 4992 UNIT C 1 38140 38140 4992 4992 UNIT B 1 38140 38140 4992 4992 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 4-UNIT NO HOUSE PANEL M M M PANEL "UNIT" PANEL "HPL1" T F 60F3 600S3 1 2 3 4 M M M 200/2 200F3 600/2 600A 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 5) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # TO UTILITY PRIMARY 1 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "3STRY, 5-UNIT METER STACK" 600A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:19 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 3 STORY WALK-UP - 5 UNIT E507 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 600 600F3 2 2 1/2" (3)350 KCM (1)#1 600 600F3 2 3 1/2" (3)500 KCM (1)#2/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE SCALE: NO SCALE1ELECTRICAL ONE-LINE - 3 STORY TOWNHOME - 5 UNIT MINIMUM SERVICE SIZE 109064 454 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 97544 406 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 216764 VA AMPS TOTAL 5 191804 24960 UNIT D 1 38584 38584 4992 4992 UNIT C 1 38140 38140 4992 4992 UNIT B 2 38140 76280 4992 9984 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 5 UNIT MINIMUM SERVICE SIZE 97544 406 HOUSE LOAD (VA) DWELLING UNIT DEMAND 97544 406 DEMAND FACTOR 0.45 TOTAL DWELLING UNIT LOAD 216764 VA AMPS TOTAL 5 191804 24960 UNIT D 1 38584 38584 4992 4992 UNIT C 1 38140 38140 4992 4992 UNIT B 2 38140 76280 4992 9984 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 5 UNIT NO HOUSE PANEL M M M PANEL "UNIT" PANEL "HPL1" T F 60F4 1 2 3 4 M M M M 60F3 800S3 200/2 200F3 800/2 800A 600S3 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 6) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. MAIN FUSES SHALL ALSO BE REDUCED TO 600A WITHOUT A HOUSE PANEL. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # TO UTILITY PRIMARY 1 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "3STRY, 6-UNIT METER STACK" 800A, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC IF NO HOUSE PANEL PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:19 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 3 STORY WALK-UP - 6 UNIT E508 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S MINIMUM SERVICE SIZE 125874 524 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 114354 476 DEMAND FACTOR 0.44 TOTAL DWELLING UNIT LOAD 259896 VA AMPS TOTAL 6 229944 29952 UNIT D 1 38584 38584 4992 4992 UNIT C 2 38140 76280 4992 9984 UNIT B 2 38140 76280 4992 9984 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 6 UNIT SCALE: NO SCALE1ELECTRICAL ONE-LINE - 3 STORY TOWNHOME - 6 UNIT MINIMUM SERVICE SIZE 114354 476 HOUSE LOAD (VA) DWELLING UNIT DEMAND 114354 476 DEMAND FACTOR 0.44 TOTAL DWELLING UNIT LOAD 259896 VA AMPS TOTAL 6 229944 29952 UNIT D 1 38584 38584 4992 4992 UNIT C 2 38140 76280 4992 9984 UNIT B 2 38140 76280 4992 9984 UNIT A 1 38800 38800 4992 4992 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 6 UNIT NO HOUSE PANEL ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 800A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - 600A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 800 800S3 3 2 1/2" (3)300 KCM N/A 800 800S3 3 3" (3)400 KCM N/A 800 800F3 3 2 1/2" (3)300 KCM (1)#1/0 800 800F3 3 3" (3)400 KCM (1)#3/0 AL 600 600S3 2 2 1/2" (3)350 KCM N/A 600 600S3 2 3 1/2" (3)500 KCM N/A 600 600F3 2 2 1/2" (3)350 KCM (1)#1 600 600F3 2 3 1/2" (3)500 KCM (1)#2/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE M M M PANEL "UNIT" PANEL "HPL1" T F 1 2 3 4 M M M M M M 60F3 800S3 200/2 200F3 800/2 800A 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 8) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # TO UTILITY PRIMARY 1 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "3STRY, 8-UNIT METER STACK" 800A, 100% RATED, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:19 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 3 STORY WALK-UP - 8 UNIT E509 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 800 800S3 3 2 1/2" (3)300 KCM N/A 800 800S3 3 3" (3)400 KCM N/A 800 800F3 3 2 1/2" (3)300 KCM (1)#1/0 800 800F3 3 3" (3)400 KCM (1)#3/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 800A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE SCALE: NO SCALE1ELECTRICAL ONE-LINE - 3 STORY TOWNHOME - 8 UNIT MINIMUM SERVICE SIZE 160844 670 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 149324 622 DEMAND FACTOR 0.43 TOTAL DWELLING UNIT LOAD 347264 VA AMPS TOTAL 8 307328 39936 UNIT D 2 38584 77168 4992 9984 UNIT C 2 38140 76280 4992 9984 UNIT B 2 38140 76280 4992 9984 UNIT A 2 38800 77600 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 8 UNIT MINIMUM SERVICE SIZE 149324 622 HOUSE LOAD (VA) DWELLING UNIT DEMAND 149324 622 DEMAND FACTOR 0.43 TOTAL DWELLING UNIT LOAD 347264 VA AMPS TOTAL 8 307328 39936 UNIT D 2 38584 77168 4992 9984 UNIT C 2 38140 76280 4992 9984 UNIT B 2 38140 76280 4992 9984 UNIT A 2 38800 77600 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 8 UNIT NO HOUSE PANEL M M M M PANEL "UNIT" 125/2 PANEL "HPL1" T F 1 2 3 4 M M M M M M 60F3 200/2 200F3 800S3 800/2 800A 10 0 / 3 M N G TYPICAL UNIT PANEL (QTY 9) ONE-LINE KEY NOTES: 1. "MSB" SHALL BE THREE TIER SERIES RATED AT 100 kAIC. BASIS OF DESIGN IS SCHNEIDER ELECTRIC (SQUARE D) EZM METER CENTER WITH THREE TIER SERIES RATING, CONSISTING OF TYPE L MAIN FUSE QOH TENANT CIRCUIT BREAKER, AND TYPE QOY TENANT PANEL CIRCUIT BREAKERS. 2. HOUSE PANEL IS OPTIONAL DEPENDING ON LOCATION AND REQUIREMENTS FOR LIGHTING OR IRRIGATION LOADS. SITE PLANS TO BE PROVIDED TO COORDINATE REQUIRED LOCATIONS. 3. CIRCUIT BREAKER FOR PV SYSTEM, PROVIDED BY EC. COORDINATE REQUIREMENTS WITH PV CONTRACTOR. 4. PV CONNECTION BY PV CONTRACTOR. 5. PROVIDE (2)2"C TO ROOF. FEEDERS BY SOLAR CONTRACTOR. FOR FUTURE USE. 6. NON-FUSED, UTILITY DISCONNECT AND PV PRODUCTION METER BY PV CONTRACTOR. # TO UTILITY PRIMARY 1 2 120/240V, 1PH, 3W PAD MOUNTED TRANSFORMER "3STRY, 9-UNIT METER STACK" 800A, 100% RATED, 120/240V, 1PH, 3W, NEMA 3R, 100kAIC PV PANEL / ARRAY 3 4 5 6 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:19 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - 3 STORY WALK-UP - 9 UNIT E510 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 800 800S3 3 2 1/2" (3)300 KCM N/A 800 800S3 3 3" (3)400 KCM N/A 800 800F3 3 2 1/2" (3)300 KCM (1)#1/0 800 800F3 3 3" (3)400 KCM (1)#3/0 AL 200 200F3 1 2" (3)#3/0 (1)#6 200 200F3 1 2" (3)250 KCM (1)#4 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 800A 2/0BJ 8BJ 6GEC 2/0GEC 4GEC 2/0GEC 2/0GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE SCALE: NO SCALE1ELECTRICAL ONE-LINE - 3 STORY TOWNHOME - 9 UNIT MINIMUM SERVICE SIZE 179390 747 HOUSE LOAD (VA)11520 11520 48 DWELLING UNIT DEMAND 167870 699 DEMAND FACTOR 0.43 TOTAL DWELLING UNIT LOAD 390396 VA AMPS TOTAL 9 345468 44928 UNIT D 2 38584 77168 4992 9984 UNIT C 3 38140 114420 4992 14976 UNIT B 2 38140 76280 4992 9984 UNIT A 2 38800 77600 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 9 UNIT MINIMUM SERVICE SIZE 167870 699 HOUSE LOAD (VA) DWELLING UNIT DEMAND 167870 699 DEMAND FACTOR 0.43 TOTAL DWELLING UNIT LOAD 390396 VA AMPS TOTAL 9 345468 44928 UNIT D 2 38584 77168 4992 9984 UNIT C 3 38140 114420 4992 14976 UNIT B 2 38140 76280 4992 9984 UNIT A 2 38800 77600 4992 9984 QTY PER UNIT TOTAL PER UNIT TOTAL GENERAL LOAD HEATING AND A/C SYSTEM VOLTAGE: 120/240, 1PH FEEDER CALCULATION FOR 9 UNIT NO HOUSE PANEL PANEL "LPL1" T F 225S4 M 225/3 225AF 225F4 1 2 208/120V, 3PH, 4W, UTILITY TRANSFORMER TO UTILITY PRIMARY 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:19 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ONE-LINE DIAGRAM - CLUBHOUSE E511 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S SCALE: NO SCALE1ELECTRICAL ONE-LINE - CLUBHOUSE LMOTOR 0 1.25 0 MOTOR 0 1 0 NONCONC. 0 0 0 0 C-PHASE LOAD MISC 0 1 0 21735 B-PHASE LOAD KITCHEN 11900 0.65 7735 22357 A-PHASE LOAD EQUIP 23526 1 23526 167 MIN. FEEDER AMPS LIGHTING 826 1.25 1033 40134 VA (W/ CONTINUOUS) RECEPT 7840 NEC 7840 7867 16.4% SPARE LOAD TYPE LOAD IN VA FACTOR DIV LOAD 39927 TOTAL VA SPARE 20/1 59 B 60 20/1 SPARE SPARE 20/1 57 A 58 20/1 SPARE SPARE 20/1 55 B 56 20/1 SPARE SPARE 20/1 53 A 54 20/1 SPARE SPARE 20/1 51 B 52 20/1 SPARE SPARE 20/1 49 A 50 20/1 SPARE SPARE 20/1 47 B 48 20/1 SPARE SPARE 20/1 45 A 46 20/1 SPARE SPARE 20/1 43 B 44 20/1 SPARE SPARE 20/1 41 A 42 20/1 SPARE SPARE 20/1 39 B 40 20/1 1200 R-FITNESS EQUIPMENT SPARE 20/1 37 A 38 20/1 1200 R-FITNESS EQUIPMENT SPARE 20/1 35 B 36 20/1 1200 R-FITNESS EQUIPMENT R-FITNESS FANS 1080 20/1 33 A 34 20/1 1200 R-FITNESS EQUIPMENT R-FITNESS RECEPT. 900 20/1 31 B 32 20/1 1200 R-FITNESS EQUIPMENT E-FIREPLACE 500 20/1 29 A 30 20/1 1200 R-FITNESS EQUIPMENT E-FIREPLACE 500 20/1 27 B 28 * 4008 * R-EXTERIOR RECEPT. 900 20/1 25 A 26 50/2 4008 E-CU-1 R-HALLWAY RECEPT. 1260 20/1 23 B 24 20/1 400 E-CP-1 R-CORNER COUNTER 540 20/1 21 A 22 20/1 1524 E-FUR-1 K-REFRIGERATOR 1000 GFCI 20/1 19 B 20 20/1 372 E-GWH-1 *4000 * *17 A 18 20/1 1500 * K-RANGE 4000 GFCI 50/2 15 B 16 20/1 1500 E-EWH-2 K-MICROWAVE 1200 GFCI 20/1 13 A 14 20/1 1500 * K-DISHWASHER 1200 GFCI 20/1 11 B 12 20/1 1500 E-EWH-1 K-DISPOSAL 500 GFCI 20/1 9 A 10 20/1 7 E-EF-2 R-ISLAND COUNTER 540 20/1 7 B 8 20/1 7 E-EF-1 R-ISLAND COUNTER 720 20/1 5 A 6 20/1 92 L-EXTERIOR LIGHTING R-KITCHEN COUNTER 360 20/1 3 B 4 20/1 588 L-FIT. & KITCH. & GREAT ROOM R-MECH & RR 540 20/1 1 A 2 20/1 146 L-BACK OF HOUSE & RR DESCRIPTION LOAD VA REMARKS O/C CKT # PH CKT # O/C REMARKS LOAD VA DESCRIPTION 60 POLES ONE SECTION 18000 MINIMUM AIC RATING FULLY RATED 200 AMP MLO 100% NEUTRAL 240/120V 1 PHASE 3 WIRE W/ GND BAR SURFACE MOUNTED PANELCH 5. THE GROUND CONDUCTOR SHALL BE COPPER UNLESS NOTED OTHERWISE. 4. FEEDER CALLOUTS DENOTED WITH AN 'S3' RATHER THAN AN 'F3' AT THE END ARE SERVICE FEEDERS AND DO NOT INCLUDE A GROUND WIRE. FROM AHJ TO DOWNSIZE CONDUCTORS. 3. NEUTRAL IS CONSIDERED CURRENT CARRYING CONDUCTOR PER THE ABOVE. CONTRACTOR TO PROVIDE WRITTEN APPROVAL 2. 3 PHASE, 4 WIRE CIRCUITS DERATED TO 80% PER NEC, ARTICLE 310.15.B.3.a. UNLESS NOTED OTHERWISE. 1. AMPACITY BASED UPON NEC, TABLE 310.15.B.16. (100% OF 75 DEGREE THWN OR THHN). NOTES: 225 225S3 1 2 1/2" (3)#4/0 N/A 225 225S3 1 2" (3)300 KCM N/A 225 225F3 1 2 1/2" (3)#4/0 (1)#4 225 225F3 1 2" (3)300 KCM (1)#2 AL OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND OCPD RATING FEEDER CALLOUT SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER ALUMINUM 3-WIRE FEEDER SCHEDULE 60 60F2 1 1" (2#)6 (1)#10 50 50F2 1 1" (2#)8 (1)#10 40 40F2 1 1" (2)#8 (1)#10 30 30F2 1 3/4" (2)#10 (1)#10 20 20F2 1 1/2" (2)#12 (1)#12 OCPD RATING FEEDER TYPE SETS CONDUIT PHASE AND/ OR NEUTRAL GND COPPER 2-WIRE FEEDER SCHEDULE ENGINEER. PRECIPITATION WITHIN THE PREVIOUS 48 HOURS DOES NOT CONSTITUTE NORMALLY DRY CONDITIONS. RESISTANCE SHALL BE ACHIEVED UNDER NORMALLY DRY CONDITIONS UNLESS OTHERWISE APPROVED BY TO GROUND WHEN TESTED ACCORDING TO IEEE 81 USING "FALL-OF-POTENTIAL" METHOD. SPECIFIED SYSTEM'S d. THE RESISTANCE OF THE GROUNDING ELECTRODE SYSTEM SHALL NOT BE GREATER THAN TWENTY FIVE OHMS COPPER, COPPERCLAD STEEL, OR OTHER UL LISTED GROUND ROD. c. WHERE NONE OF THE ABOVE ARE AVAILABLE, PROVIDE GEC FROM EQUIPMENT GROUND TO 8' LONG X 5/8" DIAMETER b. OTHER METAL BUILDING COMPONENTS, MINIMUM LISTED, MATCH EQUIPMENT GROUND OF ASSOCIATED SYSTEM. a. GROUNDING AND BONDING JUMPER CONDUCTORS ARE COPPER. GENERAL NOTES: 225A 2BJ 8BJ 6GEC 2GEC 4GEC 2GEC 2GEC - MAIN BONDING JUMPER (BJ) OTHER METAL COMPONENTS MAIN ELECTRODE MAIN METAL WATER PIPE CONCRETE ENCASED GROUND RING BUILDING STEEL WHRE PRESENT, BONDING GROUNDING ELECTRODE CONDUCTOR (GEC) CONNECTED TO SERVICE RATING BONDING/JUMPER DESIGNATION REMARKS GROUNDING AND BONDING JUMPER SCHEDULE 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:20 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - 32 UNIT E800A LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 174 121 TOTAL DEMAND (W)36118 25134 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20142.4 REMAINDER AT 40%25356 10142.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 35356 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4470 REMAINDER AT 25% 3001 - 120000 VA 35% 4200 1470 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7200 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 2700 2700 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 900 SQFT UNIT A DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 172 119 TOTAL DEMAND (W)35811 24784 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19792 REMAINDER AT 40%24480 9792 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34480 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4163.4 REMAINDER AT 25% 3001 - 120000 VA 35% 3324 1163.4 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6324 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1824 1824 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 608 SQFT UNIT A1 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 172 119 TOTAL DEMAND (W)35803 24774 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19782.4 REMAINDER AT 40%24456 9782.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34456 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4155 REMAINDER AT 25% 3001 - 120000 VA 35% 3300 1155 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6300 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1800 1800 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 600 SQFT UNIT A2 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 172 119 TOTAL DEMAND (W)35698 24654 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19662.4 REMAINDER AT 40%24156 9662.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34156 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4050 REMAINDER AT 25% 3001 - 120000 VA 35% 3000 1050 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6000 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1500 1500 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 500 SQFT UNIT A3 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 175 122 TOTAL DEMAND (W)36369 25421 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20429.2 REMAINDER AT 40%26073 10429.2 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36073 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4720.95 REMAINDER AT 25% 3001 - 120000 VA 35% 4917 1720.95 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7917 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3417 3417 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1139 SQFT UNIT B DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 172 119 TOTAL DEMAND (W)35698 24654 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19662.4 REMAINDER AT 40%24156 9662.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34156 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4050 REMAINDER AT 25% 3001 - 120000 VA 35% 3000 1050 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6000 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1500 1500 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 500 SQFT UNIT B1 DWELLING UNIT LOAD CALCULATION 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:21 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - 32 UNIT E800B LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 174 121 TOTAL DEMAND (W)36236 25269 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20276.8 REMAINDER AT 40%25692 10276.8 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 35692 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4587.6 REMAINDER AT 25% 3001 - 120000 VA 35% 4536 1587.6 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7536 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3036 3036 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1012 SQFT UNIT B2 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 176 123 TOTAL DEMAND (W)36573 25654 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20662 REMAINDER AT 40%26655 10662 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36655 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4924.65 REMAINDER AT 25% 3001 - 120000 VA 35% 5499 1924.65 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 8499 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3999 3999 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1333 SQFT UNIT C DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 172 119 TOTAL DEMAND (W)35698 24654 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19662.4 REMAINDER AT 40%24156 9662.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34156 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4050 REMAINDER AT 25% 3001 - 120000 VA 35% 3000 1050 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6000 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1500 1500 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 500 SQFT UNIT C1 DWELLING UNIT LOAD CALCULATION 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:22 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - 49 UNIT E801A LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 153 119 TOTAL DEMAND (W)31901 24788 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19795.6 REMAINDER AT 40%24489 9795.6 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34489 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4166.55 REMAINDER AT 25% 3001 - 120000 VA 35% 3333 1166.55 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6333 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 1833 1833 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 611 SQFT UNIT S1 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 173 121 TOTAL DEMAND (W)36057 25065 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20072.8 REMAINDER AT 40%25182 10072.8 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 35182 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4409.1 REMAINDER AT 25% 3001 - 120000 VA 35% 4026 1409.1 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7026 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 2526 2526 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 842 SQFT UNIT A1 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 154 120 TOTAL DEMAND (W)32032 24938 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 19945.6 REMAINDER AT 40%24864 9945.6 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 34864 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4297.8 REMAINDER AT 25% 3001 - 120000 VA 35% 3708 1297.8 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 6708 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 2208 2208 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 736 SQFT UNIT A2 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 156 122 TOTAL DEMAND (W)32442 25407 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20414.8 REMAINDER AT 40%26037 10414.8 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36037 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4708.35 REMAINDER AT 25% 3001 - 120000 VA 35% 4881 1708.35 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7881 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3381 3381 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1127 SQFT UNIT C1 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 156 122 TOTAL DEMAND (W)32475 25444 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20452 REMAINDER AT 40%26130 10452 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36130 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4740.9 REMAINDER AT 25% 3001 - 120000 VA 35% 4974 1740.9 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 7974 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3474 3474 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1158 SQFT UNIT C2 DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 156 123 TOTAL DEMAND (W)32531 25508 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20515.6 REMAINDER AT 40%26289 10515.6 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36289 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4796.55 REMAINDER AT 25% 3001 - 120000 VA 35% 5133 1796.55 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 8133 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3633 3633 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1211 SQFT UNIT C3 DWELLING UNIT LOAD CALCULATION 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:22 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - 49 UNIT E801B LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 157 123 TOTAL DEMAND (W)32644 25637 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 20645.2 REMAINDER AT 40%26613 10645.2 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 36613 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 4909.95 REMAINDER AT 25% 3001 - 120000 VA 35% 5457 1909.95 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 8457 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 3957 3957 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/208 UNIT AREA: 1319 SQFT UNIT D1 DWELLING UNIT LOAD CALCULATION 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:23 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - BROWN E802 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 139 111 TOTAL DEMAND (W)33422 26526 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21534.4 REMAINDER AT 40%28836 11534.4 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 38836 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5688 REMAINDER AT 25% 3001 - 120000 VA 35% 7680 2688 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 10680 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 6180 6180 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 2060 SQFT UNIT A DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 156 111 TOTAL DEMAND (W)37498 26711 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21719.2 REMAINDER AT 40%29298 11719.2 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 39298 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5849.7 REMAINDER AT 25% 3001 - 120000 VA 35% 8142 2849.7 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 11142 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 6642 6642 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 2214 SQFT UNIT B DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 138 109 TOTAL DEMAND (W)33088 26145 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21152.8 REMAINDER AT 40%27882 11152.8 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 37882 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5354.1 REMAINDER AT 25% 3001 - 120000 VA 35% 6726 2354.1 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 9726 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 5226 5226 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 1742 SQFT UNIT C DWELLING UNIT LOAD CALCULATION 5500 Greenwood Plaza Blvd., Suite 200 Greenwood Village, CO 80111 303.770.8884 Checked By: Project No: Drawn By:NOT FOR CONSTRUCTIONCOPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE STAMP #Date Issue/Description AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 3/12/2024 8:22:23 AM Au t o d e s k D o c s : / / L M H 1 0 . 3 1 - O n e - l i n e s / L M H 1 0 . 3 1 - E l e c t ri c a l O n e - L i n e s _ R 2 3 . r v t ELECTRICAL CALCULATIONS - 3 STORY E803 LMH000010.31 JTH RMR FO R T C O L L I N S , C O UN I O N P A R K O N E - L I N E S LA N D M A R K H O M E S REQUIRED FEEDER AMPACITY 139 110 TOTAL DEMAND (W)33409 26512 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21520 REMAINDER AT 40%28800 11520 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 38800 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5675.4 REMAINDER AT 25% 3001 - 120000 VA 35% 7644 2675.4 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 10644 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 6144 6144 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 2048 SQFT UNIT A DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 155 109 TOTAL DEMAND (W)37092 26248 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21256 REMAINDER AT 40%28140 11256 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 38140 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 15656 DEMAND FACTOR FOR 4 OR MORE APPLIANCES:1 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5444.4 REMAINDER AT 25% 3001 - 120000 VA 35% 6984 2444.4 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 9984 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 5484 5484 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 1828 SQFT UNIT B DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 138 109 TOTAL DEMAND (W)33178 26248 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21256 REMAINDER AT 40%28140 11256 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 38140 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5444.4 REMAINDER AT 25% 3001 - 120000 VA 35% 6984 2444.4 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 9984 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 5484 5484 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 1828 SQFT UNIT C DWELLING UNIT LOAD CALCULATION REQUIRED FEEDER AMPACITY 139 110 TOTAL DEMAND (W)33334 26426 OPTIONAL CALCULATION HEATING AND A/C DEMAND 4992 HEATING AND AIR CONDITIONING DEMAND 4992 ELECTRIC HEAT NAMEPLATE RATING (W): 4992 AIR CONDITIONING NAMEPLATE RATING (W): 4992 HEATING AND AIR CONDITIONING OPTIONAL CALCULATION GENERAL LOAD DEMAND 21433.6 REMAINDER AT 40%28584 11433.6 10000 W AT 100%10000 10000 DEMAND FACTORS OPTIONAL CALCULATION GENERAL LOAD TOTAL 38584 DRYER NAMEPLATE RATING (W): 5000 5000 5000 COOKING EQUIPMENT DEMAND 6000 TABLE 220.55 FACTOR 0.8 OVEN NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 COOKTOP NAMEPLATE RATING (W): TABLE 220.55 FACTOR 0.8 RANGE NAMEPLATE RATING (W): 7500 6000 7500 COOKING EQUIPMENT (1-3/4KW TO 8-3/4KW ONLY) PERMANENTLY CONNECTED APPLIANCE DEMAND 11742 DEMAND FACTOR FOR 4 OR MORE APPLIANCES: 0.75 APPLIANCE TOTAL 15656 EV CHARGER NAMEPLATE RATING (W): 6500 6500 6500 WATER HEATER NAMEPLATE RATING (W): 3000 3000 3000 FURNACE FAN NAMEPLATE RATING (W): 1956 1956 1956 MICROWAVE NAMEPLATE RATING (W): 1100 1100 1100 DISHWASHER NAMEPLATE RATING (W): 1100 1100 1100 DISPOSAL NAMEPLATE RATING (W): 1200 1200 1200 REFRIGERATOR NAMEPLATE RATING (W): 800 800 800 PERMANENTLY CONNECTED APPLIANCES LIGHTING AND SMALL APPLIANCE DEMAND 5599.8 REMAINDER AT 25% 3001 - 120000 VA 35% 7428 2599.8 3000 VA AT 100% 3000 3000 DEMAND FACTORS LIGHTING TOTAL 10428 LAUNDRY CIRCUIT 1 1500 VA 1500 1500 SMALL APPLIANCE CIRCUITS 2 1500 VA 3000 3000 LIGHTING 3 VA/SF 5928 5928 STANDARD OPTIONAL SYSTEM VOLTAGE (1PH) 120/240 UNIT AREA: 1976 SQFT UNIT D DWELLING UNIT LOAD CALCULATION