Loading...
HomeMy WebLinkAboutWORTHINGTON STORAGE - FDP220016 - SUBMITTAL DOCUMENTS - ROUND 6 - Photometric Plan0.0 0.1 0.0 0.1 0.2 0.1 0.0 0.3 0.2 0.0 0.0 0.3 0.2 0.0 0.0 0.0 0.3 0.1 0.0 0.0 0.0 0.3 0.1 0.0 0.0 0.0 0.2 0.1 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.2 0.1 0.0 0.0 0.1 0.1 0.0 0.2 0.1 0.0 0.0 0.2 0.0 0.0 0.1 0.0 0.0 0.2 0.0 0.0 0.1 0.0 0.0 0.3 0.2 0.0 0.0 0.2 0.1 0.0 0.1 0.1 0.0 0.1 0.2 0.1 0.0 0.1 0.2 0.1 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.7 0.7 1.0 1.3 1.1 0.6 1.6 1.5 1.0 0.6 2.0 1.6 0.9 0.4 1.2 1.9 1.5 0.5 0.3 0.3 1.0 1.4 1.7 0.4 0.3 0.3 0.5 0.3 1.2 1.4 1.4 0.4 0.8 1.0 0.5 0.3 0.5 1.1 1.1 1.1 1.3 0.9 0.5 0.3 0.9 0.5 0.5 1.5 1.2 1.0 0.6 0.3 1.1 1.4 1.1 1.2 1.0 0.5 0.4 0.3 1.1 1.5 1.5 0.6 0.4 0.7 0.5 0.3 0.8 1.4 1.5 0.9 1.4 0.9 0.5 0.3 0.1 0.2 0.4 1.1 1.6 1.2 0.8 0.5 0.3 0.0 0.1 0.2 0.1 1.6 1.5 0.9 0.4 0.3 0.1 0.2 0.4 1.2 1.2 0.5 0.4 0.4 0.1 0.3 0.8 1.5 1.6 0.4 0.7 0.9 0.5 0.3 0.1 0.3 0.5 0.8 1.1 1.2 1.4 0.8 0.5 0.3 0.1 0.1 0.3 0.5 1.1 1.5 1.1 0.8 0.5 0.2 0.1 0.1 0.2 0.1 0.4 1.3 1.5 1.2 0.5 0.2 0.1 0.1 0.1 0.2 0.3 1.1 1.0 1.1 0.6 0.2 0.1 0.0 0.7 1.4 1.6 1.3 0.2 0.1 0.0 0.7 1.0 1.6 1.0 0.0 0.7 1.4 1.0 0.4 0.7 0.4 0.3 0.6 0.3 0.6 1.2 1.1 0.8 1.4 1.5 0.8 1.1 1.7 0.9 1.4 1.0 0.1 0.6 0.8 0.7 1.2 4.2 0.4 0.7 0.9 1.4 4.0 5.4 0.5 0.9 1.5 2.4 3.9 4.4 3.3 0.3 0.7 1.6 2.6 3.4 4.7 4.3 2.9 1.4 0.1 0.2 0.5 1.3 3.4 4.6 4.5 4.3 2.2 0.0 0.1 0.2 0.6 1.9 3.7 2.9 3.0 0.1 0.2 0.6 1.5 1.6 0.1 0.2 0.3 T ES1 MH: 8 S3MH: 15 S1 MH: 15 S1 MH: 15 S1 MH: 15 S1MH: 15 S1 MH: 15 S1 MH: 15 S1 MH: 15 S1MH: 15 S1 MH: 15 PROPERTY LINE 2 E1.1 Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description 9 EDGE-4M-E_EDITABLE SINGLE 3472 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires 1 EDGE-4M-E_EDITABLE_1 SINGLE 11638 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires 1 EDGE-2MB-E_EDITABLE SINGLE 1560 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min 10' Beyond Illuminance Fc 0.04 0.3 0.0 N.A.N.A. entry drive Illuminance Fc 0.10 0.1 0.1 1.00 1.00 entry drive_1 Illuminance Fc 1.00 5.4 0.0 N.A.N.A. E1.1 ELECTRICAL PHOTOMETRIC SITE PLAN REVISIONS CO N S U L T I N G E N G I N E E R S CO N T R A C T O R 7/ 1 2 / 2 0 2 3 9 : 4 1 : 3 1 A M JOB NO: 2150005102 PE : ST R U C T U R A L : EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : HE N D E R S O N E N G I N E E R S , I N C . 83 1 1 W e s t S u n s e t R o a d , S u i t e 2 4 0 La s V e g a s , N V . 8 9 1 1 3 (P ) 7 0 2 . 3 6 5 . 3 5 2 2 CI V I L : 99 9 1 8 th S T . , S T E . 2 1 1 0 DE N V E R , C O 7 5 2 0 6 (P ) ( 3 0 3 ) 8 0 1 - 1 7 6 7 WW W . A R C O M U R R A Y . C O M SE L F S T O R A G E P R O J E C T f o r : Ft . C o l l i n s , C o l o r a d o DATE : 12/17/2021 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF IT IS NOT TO BE USED FOR PURPOSES. LICENSE #LICENSE #LICENSE # DEAN W. CHANDLER 54612 CONSTRUCTION PRELIMINARY SUBMITTAL REV1: 03/08/2023 SCALE: 1/32"=1'-0" PHOTOMETRIC SITE PLAN1 3/4" RNC NO SCALE POLE BASE DETAIL2 5/8" X 8' DRIVEN GROUND ROD WITH #6 CU. GROUND BONDED TO POLE GROUNDING LUG AND TO GROUND ROD ELECTRICAL CIRCUIT TO LIGHT POLE. REFER TO SITE PLAN AND PANELBOARD SCHEDULES FOR SIZES OF CONDUITS AND CONDUCTORS RNC (TYP) LINE OF GRADE OR PAVING ANCHOR BOLTS, PER MANUFACTURER GROUT POLE BASE PLATE BOND ELECTRICAL EQUIPMENT GROUNDING CONDUCTOR RUN WITH CIRCUIT TO LIGHT POLE GROUNDING LUG. HANDHOLE WITH REMOVABLE COVER AS SPECIFIED LIGHT POLE. RE: LIGHT FIXTURE SCHEDULE FOR TYPE. OPTIONS AND ACCESSORIES AS SPECIFIED. RE: LIGHT FIXTURE SCHEDULE FOR NUMBER AND TYPE OF HEADS AND CONFIGURATION Y3 Y2 Y1 REINFORCED CONCRETE FOUNDATION. SIZE AND TYPE AS REQUIRED TO MEET SITE CONDITIONS X Y1 Y3 Y2 TABLE OF DIMENSIONS* REFER TO LIGHT FIXTURE SCHEDULE FOR POLE HEIGHT 1/4 OF POLE HEIGHT Y1 *NOTE: ALL DIMENSIONS ARE APPROXIMATE AND ARE SHOWN FOR REFERENCE ONLY. POLE FOUNDATION SHALL BE DESIGNED AND SEALED BY A PROFESSIONAL STRUCTURAL OR CIVIL ENGINEER LICENSED IN THE PROJECT STATE AND SUBMITTED AS PART OF THE SUBMITTAL PROCESS. POLE HEIGHT < 16' = 1'-6" POLE HEIGHT > 16' = 2'-0" VEHICULAR AREAS - 3'-0" NON-VEHICULAR AREAS - 0'-6" X ALL EXTERIOR SITE LIGHTING SHALL BE PER CITY OF FORT COLLINS STANDARDS, LATEST EDITION (SECTION 3.2.4 - EXTERIOR SITE LIGHTING). SITE LUMEN LIMIT IS CALCULATED USING THE HARDSCAPE AREA METHOD UNDER LIGHTING CONTEXT AREA LC1. A LIMIT OF 58,466 WAS CALCULATED USING A VALUE OF 46,773 SQ. FT. AND 1.25 LUMENS PER SQUARE FEET. TOTAL LUMENS CALCULATED IS 35,222 2 2 2 NORTH (FOR REFERENCE ONLY) 16 OF 18 Sheet: 1 File: J:\Philadelphia\Programs\A-E\ARCO Murray\2050003219 Self-Storage Building - North Bergen\001\000\Rcvd\2020 1110 Kick Off meeting\SJ2286_A2.1_Floor Plan_Lvl 1-ALL PLANS.pdf Missing or invalid reference E1.2 ELECTRICAL CUTSHEETS REVISIONS CO N S U L T I N G E N G I N E E R S CO N T R A C T O R 7/ 1 2 / 2 0 2 3 9 : 4 1 : 4 3 A M JOB NO: 2150005102 PE : ST R U C T U R A L : EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : HE N D E R S O N E N G I N E E R S , I N C . 83 1 1 W e s t S u n s e t R o a d , S u i t e 2 4 0 La s V e g a s , N V . 8 9 1 1 3 (P ) 7 0 2 . 3 6 5 . 3 5 2 2 CI V I L : 99 9 1 8 th S T . , S T E . 2 1 1 0 DE N V E R , C O 7 5 2 0 6 (P ) ( 3 0 3 ) 8 0 1 - 1 7 6 7 WW W . A R C O M U R R A Y . C O M SE L F S T O R A G E P R O J E C T f o r : Ft . C o l l i n s , C o l o r a d o DATE : 12/17/2021 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF IT IS NOT TO BE USED FOR PURPOSES. LICENSE #LICENSE #LICENSE # DEAN W. CHANDLER 54612 CONSTRUCTION PRELIMINARY SUBMITTAL REV1: 03/08/2023 S1ES1 S3 ES1 S1 S3 2 17 OF 18 ELECTRICAL PRELIMINARY ONE-LINE DIAGRAM REVISIONS CO N S U L T I N G E N G I N E E R S CO N T R A C T O R 6/ 2 1 / 2 0 2 2 4 : 1 5 : 4 9 P M JOB NO: PE : ST R U C T U R A L : EL E C T R I C A L : PL U M B I N G : ME C H A N I C A L : HE N D E R S O N E N G I N E E R S , I N C . 83 1 1 W e s t S u n s e t R o a d , S u i t e 2 4 0 La s V e g a s , N V . 8 9 1 1 3 (P ) 7 0 2 . 3 6 5 . 3 5 2 2 CI V I L : 99 9 1 8 th S T . , S T E . 2 1 1 0 DE N V E R , C O 7 5 2 0 6 (P ) ( 3 0 3 ) 8 0 1 - 1 7 6 7 WW W . A R C O M U R R A Y . C O M SE L F S T O R A G E P R O J E C T f o r : Ft . C o l l i n s , C o l o r a d o DATE : DE A N W . C H A N D L E R SCALE: NONE PRELIMINARY ONE-LINE DIAGRAM1 TX-1 75 KVA 480V- 208Y/120V T2 2 4 G2 12 3 MDP ELEC ROOM 600 AMPS 480Y/277V 3Ø 4W BRACED AT 42000 A.I.C. 10 4 100A 3P 125A 3P PANEL LP1 PANEL P1 PANEL P2 (4x) 3P SPACE 125A 3P PANEL M1 12 4 11 3 110A 3P CPT R 200AS 3P 110AF ELEV 1 CONT PANEL 40 ELEVATOR ST H 11 3 M 22 4 AS 6 0 4 M GROUND BUS NEUTRAL BUS TO GROUND ROD(S) TO BUILDING FOOTING (UFER) TO WATER SERVICE TO ABOVE GROUND METAL PIPING TO STRUCTURAL STEEL TELEPHONE BOARD (TTB) TO GROUND BAR AT MAIN G6G4 G2 0 G2 0 G2 0 TG 6 G30 G30 UTILITY METER NEW PAD MOUNTED UTILITY TRANSFORMER 300KVA, 480Y/277V, 3Ø, 4W SECONDARY CT CABINET NEMA 3R D-MDP 600A 3P NEMA 3R A6 0 4 FROM UTILITY MAIN SERVICE DISCONNECT SWITCH FEEDER SCHEDULE: SIZES ARE BASED ON COPPER (CU) THHN/THWN-2 INSULATION, UNO. NUMBER DESIGNATIONS PRECEDED BY "A" INDICATE THAT THE SIZE IS BASED ON ALUMINUM (AL) WIRE. AL CONDUCTOR SIZES ARE BASED ON XHHW-2 INSULATION, UNO. ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATIONS, UNO. CONDUIT SIZES SHOWN ARE APPROPRIATE FOR SCHEDULE 40 PVC, EMT, GRS, IMC AND RMC; ADJUST SIZE AS NEEDED FOR OTHER RACEWAY TYPES. FOR ANY OTHER CONDITIONS MODIFY SIZES PER CODE. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 104 100A, (4)#3, (1)#8G, 1-1/4" C 113 110A, (3)#2, (1)#6G, 1-1/4" C 123 125A, (3)#1, (1)#6G, 1-1/4" C 124 125A, (4)#1, (1)#6G, 1-1/2" C 224 225A, (4)#4/0, (1)#4G, 2" C A604 600A, (2) 3" C, EACH W/ (4)-500kcmil, (1)#2/0G AS604 600A, (2) 3" C, EACH W/ (4)-500kcmil G2 GND, #2 COPPER GROUND, 3/4" C G20 GND, #2/0 COPPER GROUND, 3/4" C G30 GND, #3/0 COPPER GROUND, 1" C G4 GND, #4 COPPER GROUND, 3/4" C G6 GND, #6 COPPER GROUND, 3/4" C T224 225A, (4)#4/0, (1)#2 SSBJ, 2-1/2" C TG6 #6 cu, Less than 13' 17 of 17 04/21/2023 WO R T H I N G T O N S T O R A G E 18 OF 1818 OF 18