HomeMy WebLinkAboutWORTHINGTON STORAGE - FDP220016 - SUBMITTAL DOCUMENTS - ROUND 6 - Photometric Plan0.0 0.1
0.0 0.1 0.2 0.1
0.0 0.3 0.2
0.0 0.0 0.3 0.2
0.0 0.0 0.0 0.3 0.1
0.0 0.0 0.0 0.3 0.1
0.0 0.0 0.0 0.2 0.1
0.0 0.0 0.0 0.1 0.1
0.0 0.0 0.0 0.2 0.1
0.0 0.0 0.1 0.1
0.0 0.2 0.1
0.0 0.0 0.2
0.0 0.0 0.1
0.0 0.0 0.2
0.0 0.0 0.1
0.0 0.0 0.3 0.2
0.0 0.0 0.2 0.1
0.0 0.1 0.1
0.0 0.1 0.2 0.1
0.0 0.1 0.2 0.1
0.0 0.1 0.1
0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0
0.1
0.7 0.7
1.0 1.3 1.1 0.6
1.6 1.5 1.0 0.6
2.0 1.6 0.9 0.4
1.2 1.9 1.5 0.5 0.3 0.3
1.0 1.4 1.7 0.4 0.3 0.3 0.5 0.3
1.2 1.4 1.4 0.4 0.8 1.0 0.5 0.3
0.5 1.1 1.1 1.1 1.3 0.9 0.5 0.3
0.9 0.5 0.5 1.5 1.2 1.0 0.6 0.3
1.1 1.4 1.1 1.2 1.0 0.5 0.4 0.3
1.1 1.5 1.5 0.6 0.4 0.7 0.5 0.3
0.8 1.4 1.5 0.9 1.4 0.9 0.5 0.3
0.1 0.2 0.4 1.1 1.6 1.2 0.8 0.5 0.3
0.0 0.1 0.2 0.1 1.6 1.5 0.9 0.4 0.3
0.1 0.2 0.4 1.2 1.2 0.5 0.4 0.4
0.1 0.3 0.8 1.5 1.6 0.4 0.7 0.9 0.5 0.3
0.1 0.3 0.5 0.8 1.1 1.2 1.4 0.8 0.5 0.3
0.1 0.1 0.3 0.5 1.1 1.5 1.1 0.8 0.5 0.2
0.1 0.1 0.2 0.1 0.4 1.3 1.5 1.2 0.5 0.2 0.1
0.1 0.1 0.2 0.3 1.1 1.0 1.1 0.6 0.2 0.1 0.0
0.7 1.4 1.6 1.3 0.2 0.1 0.0
0.7 1.0 1.6 1.0 0.0
0.7 1.4 1.0 0.4
0.7 0.4 0.3 0.6
0.3 0.6 1.2 1.1
0.8 1.4 1.5
0.8 1.1 1.7
0.9 1.4 1.0
0.1 0.6 0.8 0.7 1.2 4.2
0.4 0.7 0.9 1.4 4.0 5.4
0.5 0.9 1.5 2.4 3.9 4.4 3.3
0.3 0.7 1.6 2.6 3.4 4.7 4.3 2.9 1.4
0.1 0.2 0.5 1.3 3.4 4.6 4.5 4.3 2.2
0.0 0.1 0.2 0.6 1.9 3.7 2.9 3.0
0.1 0.2 0.6 1.5 1.6
0.1 0.2 0.3
T
ES1
MH: 8
S3MH: 15
S1
MH: 15
S1
MH: 15
S1
MH: 15
S1MH: 15
S1
MH: 15
S1
MH: 15
S1
MH: 15
S1MH: 15
S1
MH: 15
PROPERTY LINE
2
E1.1
Luminaire Schedule
Symbol Qty Label Arrangement Total Lamp Lumens LLF Description
9 EDGE-4M-E_EDITABLE SINGLE 3472 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires
1 EDGE-4M-E_EDITABLE_1 SINGLE 11638 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires
1 EDGE-2MB-E_EDITABLE SINGLE 1560 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires
Calculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
10' Beyond Illuminance Fc 0.04 0.3 0.0 N.A.N.A.
entry drive Illuminance Fc 0.10 0.1 0.1 1.00 1.00
entry drive_1 Illuminance Fc 1.00 5.4 0.0 N.A.N.A.
E1.1
ELECTRICAL
PHOTOMETRIC SITE PLAN
REVISIONS
CO
N
S
U
L
T
I
N
G
E
N
G
I
N
E
E
R
S
CO
N
T
R
A
C
T
O
R
7/
1
2
/
2
0
2
3
9
:
4
1
:
3
1
A
M
JOB NO: 2150005102
PE :
ST
R
U
C
T
U
R
A
L
:
EL
E
C
T
R
I
C
A
L
:
PL
U
M
B
I
N
G
:
ME
C
H
A
N
I
C
A
L
:
HE
N
D
E
R
S
O
N
E
N
G
I
N
E
E
R
S
,
I
N
C
.
83
1
1
W
e
s
t
S
u
n
s
e
t
R
o
a
d
,
S
u
i
t
e
2
4
0
La
s
V
e
g
a
s
,
N
V
.
8
9
1
1
3
(P
)
7
0
2
.
3
6
5
.
3
5
2
2
CI
V
I
L
:
99
9
1
8
th
S
T
.
,
S
T
E
.
2
1
1
0
DE
N
V
E
R
,
C
O
7
5
2
0
6
(P
)
(
3
0
3
)
8
0
1
-
1
7
6
7
WW
W
.
A
R
C
O
M
U
R
R
A
Y
.
C
O
M
SE
L
F
S
T
O
R
A
G
E
P
R
O
J
E
C
T
f
o
r
:
Ft
.
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
DATE : 12/17/2021
THIS DOCUMENT IS RELEASED
FOR THE PURPOSE OF
IT IS NOT TO BE USED FOR
PURPOSES.
LICENSE #LICENSE #LICENSE #
DEAN W. CHANDLER
54612
CONSTRUCTION
PRELIMINARY SUBMITTAL
REV1: 03/08/2023
SCALE: 1/32"=1'-0"
PHOTOMETRIC SITE PLAN1
3/4" RNC
NO SCALE
POLE BASE DETAIL2
5/8" X 8' DRIVEN GROUND ROD
WITH #6 CU. GROUND BONDED
TO POLE GROUNDING LUG AND
TO GROUND ROD
ELECTRICAL CIRCUIT TO LIGHT
POLE. REFER TO SITE PLAN AND
PANELBOARD SCHEDULES FOR
SIZES OF CONDUITS AND
CONDUCTORS
RNC (TYP)
LINE OF GRADE OR PAVING
ANCHOR BOLTS, PER
MANUFACTURER
GROUT
POLE BASE PLATE
BOND ELECTRICAL EQUIPMENT
GROUNDING CONDUCTOR RUN WITH
CIRCUIT TO LIGHT POLE
GROUNDING LUG.
HANDHOLE WITH REMOVABLE
COVER AS SPECIFIED
LIGHT POLE. RE: LIGHT FIXTURE
SCHEDULE FOR TYPE. OPTIONS AND
ACCESSORIES AS SPECIFIED.
RE: LIGHT FIXTURE SCHEDULE FOR
NUMBER AND TYPE OF HEADS AND
CONFIGURATION
Y3
Y2
Y1
REINFORCED CONCRETE
FOUNDATION. SIZE AND TYPE AS
REQUIRED TO MEET SITE
CONDITIONS
X
Y1
Y3
Y2
TABLE OF DIMENSIONS*
REFER TO LIGHT FIXTURE
SCHEDULE FOR POLE HEIGHT
1/4 OF POLE HEIGHT Y1
*NOTE:
ALL DIMENSIONS ARE APPROXIMATE
AND ARE SHOWN FOR REFERENCE
ONLY.
POLE FOUNDATION SHALL BE DESIGNED
AND SEALED BY A PROFESSIONAL
STRUCTURAL OR CIVIL ENGINEER LICENSED
IN THE PROJECT STATE AND SUBMITTED AS
PART OF THE
SUBMITTAL PROCESS.
POLE HEIGHT < 16' = 1'-6"
POLE HEIGHT > 16' = 2'-0"
VEHICULAR AREAS - 3'-0"
NON-VEHICULAR AREAS - 0'-6"
X
ALL EXTERIOR SITE LIGHTING SHALL BE PER CITY OF FORT COLLINS
STANDARDS, LATEST EDITION (SECTION 3.2.4 - EXTERIOR SITE LIGHTING).
SITE LUMEN LIMIT IS CALCULATED USING THE
HARDSCAPE AREA METHOD UNDER LIGHTING
CONTEXT AREA LC1. A LIMIT OF 58,466 WAS
CALCULATED USING A VALUE OF 46,773 SQ. FT. AND
1.25 LUMENS PER SQUARE FEET. TOTAL LUMENS
CALCULATED IS 35,222
2
2
2
NORTH
(FOR REFERENCE ONLY)
16 OF 18
Sheet: 1
File: J:\Philadelphia\Programs\A-E\ARCO Murray\2050003219 Self-Storage Building - North Bergen\001\000\Rcvd\2020 1110 Kick Off meeting\SJ2286_A2.1_Floor Plan_Lvl 1-ALL PLANS.pdf
Missing or invalid reference
E1.2
ELECTRICAL
CUTSHEETS
REVISIONS
CO
N
S
U
L
T
I
N
G
E
N
G
I
N
E
E
R
S
CO
N
T
R
A
C
T
O
R
7/
1
2
/
2
0
2
3
9
:
4
1
:
4
3
A
M
JOB NO: 2150005102
PE :
ST
R
U
C
T
U
R
A
L
:
EL
E
C
T
R
I
C
A
L
:
PL
U
M
B
I
N
G
:
ME
C
H
A
N
I
C
A
L
:
HE
N
D
E
R
S
O
N
E
N
G
I
N
E
E
R
S
,
I
N
C
.
83
1
1
W
e
s
t
S
u
n
s
e
t
R
o
a
d
,
S
u
i
t
e
2
4
0
La
s
V
e
g
a
s
,
N
V
.
8
9
1
1
3
(P
)
7
0
2
.
3
6
5
.
3
5
2
2
CI
V
I
L
:
99
9
1
8
th
S
T
.
,
S
T
E
.
2
1
1
0
DE
N
V
E
R
,
C
O
7
5
2
0
6
(P
)
(
3
0
3
)
8
0
1
-
1
7
6
7
WW
W
.
A
R
C
O
M
U
R
R
A
Y
.
C
O
M
SE
L
F
S
T
O
R
A
G
E
P
R
O
J
E
C
T
f
o
r
:
Ft
.
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
DATE : 12/17/2021
THIS DOCUMENT IS RELEASED
FOR THE PURPOSE OF
IT IS NOT TO BE USED FOR
PURPOSES.
LICENSE #LICENSE #LICENSE #
DEAN W. CHANDLER
54612
CONSTRUCTION
PRELIMINARY SUBMITTAL
REV1: 03/08/2023
S1ES1
S3
ES1 S1
S3
2
17 OF 18
ELECTRICAL
PRELIMINARY ONE-LINE
DIAGRAM
REVISIONS
CO
N
S
U
L
T
I
N
G
E
N
G
I
N
E
E
R
S
CO
N
T
R
A
C
T
O
R
6/
2
1
/
2
0
2
2
4
:
1
5
:
4
9
P
M
JOB NO:
PE :
ST
R
U
C
T
U
R
A
L
:
EL
E
C
T
R
I
C
A
L
:
PL
U
M
B
I
N
G
:
ME
C
H
A
N
I
C
A
L
:
HE
N
D
E
R
S
O
N
E
N
G
I
N
E
E
R
S
,
I
N
C
.
83
1
1
W
e
s
t
S
u
n
s
e
t
R
o
a
d
,
S
u
i
t
e
2
4
0
La
s
V
e
g
a
s
,
N
V
.
8
9
1
1
3
(P
)
7
0
2
.
3
6
5
.
3
5
2
2
CI
V
I
L
:
99
9
1
8
th
S
T
.
,
S
T
E
.
2
1
1
0
DE
N
V
E
R
,
C
O
7
5
2
0
6
(P
)
(
3
0
3
)
8
0
1
-
1
7
6
7
WW
W
.
A
R
C
O
M
U
R
R
A
Y
.
C
O
M
SE
L
F
S
T
O
R
A
G
E
P
R
O
J
E
C
T
f
o
r
:
Ft
.
C
o
l
l
i
n
s
,
C
o
l
o
r
a
d
o
DATE :
DE
A
N
W
.
C
H
A
N
D
L
E
R
SCALE: NONE
PRELIMINARY ONE-LINE DIAGRAM1
TX-1
75 KVA
480V-
208Y/120V
T2
2
4
G2
12
3
MDP ELEC ROOM
600 AMPS 480Y/277V 3Ø 4W BRACED AT 42000 A.I.C.
10
4
100A
3P
125A
3P
PANEL
LP1
PANEL
P1
PANEL
P2
(4x) 3P SPACE
125A
3P
PANEL
M1
12
4
11
3
110A
3P
CPT
R
200AS
3P
110AF
ELEV 1
CONT
PANEL
40
ELEVATOR
ST
H
11
3
M
22
4
AS
6
0
4
M
GROUND BUS
NEUTRAL BUS
TO GROUND ROD(S)
TO BUILDING FOOTING (UFER)
TO WATER SERVICE
TO ABOVE GROUND METAL PIPING
TO STRUCTURAL STEEL
TELEPHONE BOARD (TTB)
TO GROUND BAR AT MAIN
G6G4
G2
0
G2
0
G2
0
TG
6
G30
G30
UTILITY
METER
NEW PAD MOUNTED UTILITY TRANSFORMER
300KVA, 480Y/277V, 3Ø, 4W SECONDARY
CT
CABINET
NEMA 3R
D-MDP
600A
3P
NEMA 3R
A6
0
4
FROM UTILITY
MAIN
SERVICE
DISCONNECT
SWITCH
FEEDER SCHEDULE:
SIZES ARE BASED ON COPPER (CU) THHN/THWN-2
INSULATION, UNO. NUMBER DESIGNATIONS
PRECEDED BY "A" INDICATE THAT THE SIZE IS
BASED ON ALUMINUM (AL) WIRE. AL CONDUCTOR
SIZES ARE BASED ON XHHW-2 INSULATION, UNO.
ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C
RATED TERMINATIONS, UNO. CONDUIT SIZES
SHOWN ARE APPROPRIATE FOR SCHEDULE 40 PVC,
EMT, GRS, IMC AND RMC; ADJUST SIZE AS NEEDED
FOR OTHER RACEWAY TYPES. FOR ANY OTHER
CONDITIONS MODIFY SIZES PER CODE. REFER TO
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
104 100A, (4)#3, (1)#8G, 1-1/4" C
113 110A, (3)#2, (1)#6G, 1-1/4" C
123 125A, (3)#1, (1)#6G, 1-1/4" C
124 125A, (4)#1, (1)#6G, 1-1/2" C
224 225A, (4)#4/0, (1)#4G, 2" C
A604 600A, (2) 3" C, EACH W/ (4)-500kcmil, (1)#2/0G
AS604 600A, (2) 3" C, EACH W/ (4)-500kcmil
G2 GND, #2 COPPER GROUND, 3/4" C
G20 GND, #2/0 COPPER GROUND, 3/4" C
G30 GND, #3/0 COPPER GROUND, 1" C
G4 GND, #4 COPPER GROUND, 3/4" C
G6 GND, #6 COPPER GROUND, 3/4" C
T224 225A, (4)#4/0, (1)#2 SSBJ, 2-1/2" C
TG6 #6 cu, Less than 13'
17 of 17
04/21/2023
WO
R
T
H
I
N
G
T
O
N
S
T
O
R
A
G
E
18 OF 1818 OF 18