Loading...
HomeMy WebLinkAboutFORT COLLINS RESCUE MISSION - FDP230022 - SUBMITTAL DOCUMENTS - ROUND 2 - Responses (3)DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Kl a r a R o s s o u w La y o u t : CO V E R Pr i n t e d O n : 11 / 1 / 2 0 2 3 4 : 2 4 P M Fi l e N a m e : CO V E R . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N ENGINEER ARCHITECT NORTHERN ENGINEERING Blaine Mathisen 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 PLANNER/LANDSCAPE ARCHITECT OWNER FORT COLLINS RESCUE MISSION, INC 6100 Smith Road Denver, CO 80216 COVER PDP SUBMITTAL FORT COLLINS RESCUE MISSION 11-01-2023PDP ROUND 101 FORT COLLINS, CO KR HJ R22-030 C OWNER (SIGNED)Date THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS THIS DAY OF MY COMMISSION EXPIRES: AS . (PRINT NAME) 20 .A.D., BY THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER'S CERTIFICATE Director Signature PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF ________, 20__. SITE PLAN NOTES 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.[IF APPLICABLE -- INCLUDE LANGUAGE FOR ANY MODIFICATIONS AND CONDITIONS APPROVED WITH PDP/ODP]. 7.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 8.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 9.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 10.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 11.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 12.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. AND, IF APPLICABLE: 13.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 14.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 15.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND Revised November 12, 2015 3 LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 16.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. FORT COLLINS RESCUE MISSION PROJECT DEVELOPMENT PLAN NORTH VICINITY MAP SCALE: NTS PROJECT PARKING PROVIDED *REQUIRED LONG-TERM PARKING STALLS 32 N/A HANDICAP 3 1 TOTAL 35 1 BICYCLE PARKING PROVIDED REQUIRED * BICYCLE SPACES 39 N/A FLOOR AREA RATIO LOT 1, BLOCK 1 BUILDING AREA (SF)40,612 LOT AREA (SF)120789 FLOOR AREA RATIO (LOT 1, BLOCK 1)0.34 GROSS GROSS AREA 131,631 SF (3.02 AC) EXISTING ZONING SERVICE COMMERCIAL DISTRICT (C-S) NET NET AREA 131,631 SF (3.02 AC) DENSITY AREA COVERAGE NET AREA (SF)% BUILDING COVERAGE 29,952 22.75 DRIVES AND PARKING 18,150 13.79 OPEN SPACE AND LANDSCAPE 62,378 47.39 HARDSCAPE (WALKS & PLAZAS)20,227 15.37 *ACTIVE RECREATIONAL USE 924 0.70 TOTAL NET COVERAGE 131,631.00 SF (3.02 AC)100.00 BUILDING HEIGHT MAXIMUM HEIGHT STORIES PROPOSED BUILDING (2-STORY): 33' - 4" (1-STORY): 24' - 9 1 2 "1 & 2 LAND USE CHART LEGAL DESCRIPTION LOT 2, MASON STREET INFRASTRUCTURE, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. CO L L E G E A V E . HICKORY ST. M A S O N S T . WILLOX LN * PARKING STUDY AND ALTERNATIVE COMPLIANCE FOR PARKING IS INCLUDED IN THIS PROPOSAL. HIBDON COURT R A I L R O A D SITE Sheet List Table Sheet Number Sheet Title C COVER L1 OVERALL SITE PLAN L2 SITE PLAN ENLARGEMENT 1 L3 SITE PLAN ENLARGEMENT 2 L4 SITE DETAILS L5 LANDSCAPE NOTES & DETAILS L6 OVERALL LANDSCAPE PLAN L7 LANDSCAPE ENLARGEMENT 1 L8 LANDSCAPE ENLARGEMENT 2 A3.00 OVERALL FLOOR PLAN A4.00 EXTERIOR ELEVATIONS A4.01 EXTERIOR ELEVATIONS A4.20 3D PERSPECTIVES A4.21 3D PERSPECTIVES A5.00 BUILDING SECTIONS A9.00 DETAILS P SITE PHOTOMETRIC P1 SITE LIGHTING DETAILS P2 SITE LIGHTING DETAILS 8" W 8" W 8" W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 12" W 12 " S S 12 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S E E E E E E E E E 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 12" SS 12" SS G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E EEEEEEE E T F T F FD C UDUDUDUD UD EM GM E E ELEC F E S M VAULT ELEC CABLE ELEC CTV CTV X X X CT V CT V CT V CT V CT V CT V CTV CT V CTV CTV CTV OHU OHU OHU X X X X X X X X X CTV CTV CTV CT V CTV CTV CT V CTV CTV G G G G G G G G G SS SS SS SS SS SS SS D HY D S F E S F E S X X X W W W W W W D X 6 10 9 3 7 MATCH LINE SEE SHEET L2 MATCH LINE SEE SHEET L3 6 10 9 3 7 MA S O N S T R E E T (7 1 ' R . O . W . ) M A S O N S T R E E T ( 3 8 ' R . O . W . ) HIBDON COURT (45' R.O.W.) RAIN G A R D E N RAIN GARDEN HICKORY REGIONAL DETENTION POND PROPOSED BUILDING ~ 29,954 SQFT, 2 STORIES P R O P E R T Y B O U N D A R Y OUTDOOR AMENITY OUTDOOR AMENITY LOT 1 LOT 3 LOT 2 WANKIER LANCE, 1401 N. COLLEGE AVENUE FORT COLLINS, CO WOOD RONALD G/ JENNIFER L/ WILLARD E, 122 HIBDON COURT FORT COLLINS, CO THOMPSON PROPERTIES LLC 1319 N, COLLEGE AVENUE FORT COLLINS, CO GRATITUDE LLC 1303 N. COLLEGE AVENUE FORT COLLINS. CO 60'-0" DRAINAGE EASEMENT 20'-0" EMERGENCY ACCESS EASEMENT 10'-0" ACCESS EASEMENT 20'-0" EMERGENCY ACCESS EASMENT 40'-0" DRAINAGE EASMENT G E W FO X UD W G SS E FS FS  LEGEND = STREET LIGHT = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = PROJECT/PROPERTY BOUNDARY = LOT LINE = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = EXISTING STORMWATER UTILITY = FIRE SERVICE LINE = PARKING STALL COUNT = EXISTING TOPOGRAPHY = PROPOSED GRADING = MATCH LINE = CANAL IMPORTATION FLOODWAY = CANAL IMPORTATION 100 YEAR FLOODPLAIN = TRANSFORMER = EXISTING TREE TO REMAIN = EXISTING SIGN = FIRE HYDRANT DESCRIPTION SHRUB BED CONCRETE ENHANCED CONCRETE CRUSHER FINES SYMBOL = 6' PRIVACY FENCE = BIKE RACK, TYP = VERTICAL BIKE RACK = TABLES, TYP. = LAWN CHAIR, TYP = SHADE STRUCTURE, TYP. = 6' METAL FENCE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Kl a r a R o s s o u w La y o u t : L1 O V E R A L L S I T E P L A N Pr i n t e d O n : 11 / 1 / 2 0 2 3 4 : 2 4 P M Fi l e N a m e : Si t e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 OVERALL SITE PLAN PDP SUBMITTAL FORT COLLINS RESCUE MISSION FORT COLLINS, CO KR LO R22-030 L1 NORTH 0 20 40 80 SCALE: 1"=40'-0" SHEET L2 SHEET L3 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8 " W 8 " W 8 " W 12" W 12" W 12 " S S 12 " S S 12 " S S 12 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S G G G G G G G G G G G G E E E E E E E E E E E E E EE E E E T F FD C UDUDUDUDUDUDUD UD GM CTV X X X X X X X X X G G G G G H Y D S W W 7 MATCH LINE SEE SHEET L2 MATCH LINE SEE SHEET L3 7 9'-0" RAIN GARDEN PROPERTY BOUNDARY PR O P E R T Y B O U N D A R Y OVERNIGHT SHELTER COURTYARD STAFF COURTYARD MA S O N S T R E E T (7 1 ' R . O . W . ) HIBDON COURT (45' R.O.W.) PROPOSED BUILDING ~ 29,954 SQFT, 2 STORIES LOT 2 WOOD RONALD G/ JENNIFER L/ WILLARD E, 122 HIBDON COURT FORT COLLINS, CO STREETLIGHT, TYP. TRANSFORMER, TYP. WATER METER, RE: CIVIL VERTICAL BIKE RACK, 9 SPACES STREETLIGHT, TYP. BIKE RACK, TYP. 10 SPACES RAMP WITH RAILING EXIT ONLY DOORWAY CONCRETE WEIR, RE CIVIL HYDRANT, TYP. 2 RISERS, WITH RAILING 6' PRIVACY FENCE (FENCE REPLACEMENT TO BE COORDINATED WITH PROPERTY OWNER) BIKE RACKS, TYP. 20 SPACES 6' METAL FENCE 9'-0"9'-0" 6'-0" SIDEWALK 5'-0" WALK 5'-0" WALK 26'-6" 5'-0" WALK 78'-1" 80'-0" 46'-3" 20'-0" EMERGENCY ACCESS EASEMENT 12'-0" 20'-0" EMERGENCY ACCESS EASMENT 40'-0" DRAINAGE EASMENT 9'-0" UTILITY EASEMENT 6'-0" PUBLIC SIDEWALK 8'-0" TREE LAWN G E W FO X UD W G SS E FS FS  LEGEND = STREET LIGHT = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = PROJECT/PROPERTY BOUNDARY = LOT LINE = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = EXISTING STORMWATER UTILITY = FIRE SERVICE LINE = PARKING STALL COUNT = EXISTING TOPOGRAPHY = PROPOSED GRADING = MATCH LINE = CANAL IMPORTATION FLOODWAY = CANAL IMPORTATION 100 YEAR FLOODPLAIN = TRANSFORMER = EXISTING TREE TO REMAIN = EXISTING SIGN = FIRE HYDRANT DESCRIPTION SHRUB BED CONCRETE ENHANCED CONCRETE CRUSHER FINES SYMBOL = 6' PRIVACY FENCE = BIKE RACK, TYP = VERTICAL BIKE RACK = TABLES, TYP. = LAWN CHAIR, TYP = SHADE STRUCTURE, TYP. = 6' METAL FENCE 8" W 8 " W 12 " S S 1 2 " S S 1 2 " S S G G G G G E E E E E E TF FD C UD EM GM ELECXG D HY D S 6 10 9 3 7 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Kl a r a R o s s o u w La y o u t : L2 S I T E P L A N E N L A R G E M E N T 1 Pr i n t e d O n : 11 / 1 / 2 0 2 3 4 : 2 5 P M Fi l e N a m e : Si t e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 SITE PLAN ENLARGEMENT 1 PDP SUBMITTAL FORT COLLINS RESCUE MISSION 11-01-2023PDP ROUND 101 FORT COLLINS, CO KR HJ/LO R22-030 L2 NORTH 0 10 20 40 SCALE: 1"=20'-0"KEY MAP SHEET L2 SHEET L3 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S G G G G G G G G G G G G G G E E E E E E E E E E E E E EE E E E T F UD UD EM E E E E E E CTV D XX 6 10 9 3 MATCH LINE SEE SHEET L2 MATCH LINE SEE SHEET L3 6 10 9 3 RAIN G A R D E N DAY-USE AREA COURTYARD M A S O N S T R E E T ( 3 8 ' R . O . W . ) P R O P E R T Y B O U N D A R Y PROPOSED BUILDING ~ 29,954 SQFT, 2 STORIES STREETLIGHT, TYP. STREETLIGHT, TYP. DROP-OFF AND LOADING ZONE CONCRETE WEIR, RE: CIVIL MECHANICAL GEAR, RE:CIVIL TRASH AND RECYCLING ENCLOSURES, RE: ARCH EGRESS GATE TO BE EQUIPPED WITH KNOX GATE KEY EGRESS GATE TO BE EQUIPPED WITH KNOX GATE KEY 18" RETAINING WALLS, TYP. STAIRS AND RAILING BIKE RACKS, TYP. 20 SPACES 6' METAL FENCE 6' PRIVACY FENCE 9'-0" 8'-0" 9'-5" 8'-0" 6'-0" SIDEWALK 6'-0" SIDEWALK 10'-3" 9'-0" 5'-0" WALK 6'-0" SIDEWALK 5'-0" WALK 100'-4" 20'-0" EMERGENCY ACCESS EASEMENT 10'-0" ACCESS EASEMENT 17'-0" 17'-0" 6'-0" 8'-0"29'-2" 17'-0" 84'-7" 60'-0" DRAINAGE EASEMENT 9'-0" UTILITY EASEMENT G E W FO X UD W G SS E FS FS  LEGEND = STREET LIGHT = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING FENCE = PROJECT/PROPERTY BOUNDARY = LOT LINE = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = EXISTING STORMWATER UTILITY = FIRE SERVICE LINE = PARKING STALL COUNT = EXISTING TOPOGRAPHY = PROPOSED GRADING = MATCH LINE = CANAL IMPORTATION FLOODWAY = CANAL IMPORTATION 100 YEAR FLOODPLAIN = TRANSFORMER = EXISTING TREE TO REMAIN = EXISTING SIGN = FIRE HYDRANT DESCRIPTION SHRUB BED CONCRETE ENHANCED CONCRETE CRUSHER FINES SYMBOL = 6' PRIVACY FENCE = BIKE RACK, TYP = VERTICAL BIKE RACK = TABLES, TYP. = LAWN CHAIR, TYP = SHADE STRUCTURE, TYP. = 6' METAL FENCE 8" W 8 " W 12 " S S 1 2 " S S 1 2 " S S G G G G G E E E E E E TF FD C UD EM GM ELECXG D HY D S 6 10 9 3 7 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Kl a r a R o s s o u w La y o u t : L3 S I T E P L A N E N L A R G E M E N T 2 Pr i n t e d O n : 11 / 1 / 2 0 2 3 4 : 2 5 P M Fi l e N a m e : Si t e P l a n . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 SITE PLAN ENLARGEMENT 2 PDP SUBMITTAL FORT COLLINS RESCUE MISSION 11-01-2023PDP ROUND 101 FORT COLLINS, CO KR HJ/LO R22-030 L3 NORTH 0 10 20 40 SCALE: 1"=20'-0"KEY MAP SHEET L2 SHEET L3 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Kl a r a R o s s o u w La y o u t : L4 S I T E D E T A I L S Pr i n t e d O n : 11 / 1 / 2 0 2 3 4 : 2 5 P M Fi l e N a m e : La n d s c a p e N o t e s & D e t a i l s . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ENGINEER ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 PLANNER/LANDSCAPE ARCHITECT OWNER FORT COLLINS RESCUE MISSION 316 Jefferson St. Fort Collins, CO 80524 p. 970.224.4302 SITE DETAILS PDP SUBMITTAL FORT COLLINS RESCUE MISSION 11-01-2023PDP ROUND 101 FORT COLLINS, CO KR HJ/LO R22-030 L4 6' METAL FENCE 3/4" 1'-0" 2"2" 2"X3"X 3 16" STEEL CHANNEL 1"X1" TUBULAR STL. BARS 1 8" THK. @ 4" O.C. (TYP.) 4"X4"X1 4" STL. TUBE POST CAP AT TOP (TYP.) 8'-0" OC MAX BETWEEN METAL POSTS 6'-0" 1 OP-FO3-01 6'-0" 8' TYP. 6' PRIVACY FENCE 3/4" 1'-0" ELEVATION 2 OP-FO3-03 BIKE RACK MODEL: DERO HOOP RACK POWDER COAT FINISH. COLOR TO MATCH BUILDING FACADE DETAIL. TBD SURFACE MOUNTED EACH LOOP RACK CAN ACCOMODATE TWO BIKES, ONE ON EITHER SIDE. LOOP RACK 3/4" 1'-0"OP-FO3-04 3