HomeMy WebLinkAboutFORT COLLINS RESCUE MISSION - FDP230022 - SUBMITTAL DOCUMENTS - ROUND 2 - Irrigation PlansINSTALLATION GENERAL NOTES 1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION SYSTEM (NOT OBTAINED) OF 80 PSI, AT A MAXIMUM PEAK FLOW OF 10 GPM AT THE EXISTING 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 1.1.IRRIGATION TAP, METER, SERVICE LINES, AND BACKFLOW SHALL ALL BE THE SAME SIZE, AS STATED ABOVE. 2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL SPRINKLERS MAY BE REQUIRED. 8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN WITHIN THE 3'-5' RANGE NOTED ABOVE. 9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 14.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 14.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS 15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 8 SERIES HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SPRAY NOZZLES 30 HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 10 SERIES HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SPRAY NOZZLES 30 HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 12 SERIES HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SPRAY NOZZLES 30 HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 15 SERIES HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SPRAY NOZZLES 30 HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 4X STRIP SPRAY HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION SPRAY NOZZLES 30 HUNTER MP STRIP PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LST=IVORY LEFT STRIP, SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP. 40 HUNTER MP1000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. 40 HUNTER MP2000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. 40 HUNTER MP3000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. 40 HUNTER MP3500 PROS-06-PRS40-CV TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210. 40 HUNTER MP800SR PROS-06-PRS40-CV TURF ROTATOR, 6.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) 40 SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-100-PRB-COM WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM DRIP FLUSH VALVE 3/4" PVC BALL VALVE SYMBOL MANUFACTURER/MODEL/DESCRIPTION EXISTING VALVE ASSEMBLY EXISTING REMOTE CONTROL VALVE TO REMAIN REMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY. QUICK COUPLER ASSEMBLY RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH CORROSION-RESISTANT STAINLESS STEEL SPRING, THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY. ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. EXISTING BACKFLOW BACKFLOW, MASTER VALVE, AND FLOW SENSOR WERE INSTALLED WITH MASON STREET INFRASTRUCTURE PROJECT. FIELD LOCATE AND PROTECT IN PLACE EXISTING CONTROLLER EXISTING CONTROLLER - PROTECT IN PLACE. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. IRRIGATION LATERAL LINE: NATIVE PLANTING DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING MODEL TLCV6-18. IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 EXISTING MAINLINE TO REMAIN PIPE SLEEVE: PVC SCHEDULE 40 INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL SHARE THE SAME SLEEVE. A IRRIGATION_SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 0 Pr i n t e d O n : 2/ 1 4 / 2 0 2 4 1 1 : 1 0 A M Fi l e N a m e : IR - F T R E S C U E M I S S I O N . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 1 PIP SET 02/14/24 IRRIGATION LEGEND AND NOTES PDP SUBMITTAL FORT COLLINS RESCUE MISSION FORT COLLINS, CO KR HJ/LO R22-030 IR1.0 NORTH 0 10 20 40 SCALE: 1"=20'-0" MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com ELEC CTV X X X X X X X X X G G G G G SS SS SS SS SS SS SS SS SS SS SS H Y D S W W 1 LOT PROPOSED BUILDING ~ SQFT, 2 STORIES 2A 1" A 'ULS1" A 'ULS1" 4 4 A 1" A 'ULS1" A 'ULS1" A 'ULS1" A 11" A 11" A 11"A 11" A 11" A 11" A 11" A 11" A 1" EXISTING TEMPORARY IRRIGATION INSTALLED FOR LOT 2 DURING MASON STREET INFRASTRUCTURE PROJECT SHALL BE REMOVED, INCLUDING MAINLINE, VALVES, HEADS, ETC. POC NO1. AND ASSOCIATED MAINLINE AND VALVES, AS NOTED, SHALL REMAIN, PROTECTED IN PLACE. ELEC G SS SS SS SS SS SS SS D H YD S F ES EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. SYMBOL DESCRIPTION CONTRACTOR SHALL FIELD LOCATE EXISTING IRRIGATION MAINLINE, WIRES, AND GATE VALVE, AT THE APPROXIMATE LOCATION SHOWN. MAKE NEW MAINLINE CONNECTION AND ROUTE AS INDICATED. MAKE WIRE SPLICE WITH 3' COIL IN SEPARATE 6" ROUND VALVE BOX. CONTRACTOR SHALL FIELD LOCATE EXISTING IRRIGATION POC, INCLUDING BACKFLOW, MASTER VALVE, AND FLOW SENSOR, AT THE APPROX. LOCATION SHOWN. PROTECT IN PLACE. FIELD LOCATE EXISTING REMOTE CONTROL VALVE AND MAKE NEW LATERAL LINE CONNECTION AS INDICATED. ROUTE AS SHOWN. PROTECT IN PLACE AND REPAIR DAMAGES AS NECESSARY. CONTRACTOR SHALL FIELD LOCATE EXISTING MAINLINE AND REMOTE CONTROL VALVE FOR EXISTING RIGHT-OF-WAY SOD AT THE APPROX. LOCATION SHOWN. PROTECT IN PLACE AND REPAIR DAMAGES AS NECESSARY.  A   REFERENCE NOTES SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 1 Pr i n t e d O n : 2/ 1 4 / 2 0 2 4 1 1 : 1 0 A M Fi l e N a m e : IR - F T R E S C U E M I S S I O N . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 1 PIP SET 02/14/24 IRRIGATION PLAN PDP SUBMITTAL FORT COLLINS RESCUE MISSION FORT COLLINS, CO KR HJ/LO R22-030 IR1.1 NORTH 0 10 20 40 SCALE: 1"=20'-0" KEY MAP MATCHLINE - SEE SHEET IR1.2 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com IR1.1 IR1.2 CTV CTV CTV CTV CTV OHU OHU OHU OHU OHU CTV D F E S F E S XX X X EXISTING CONTROLLER 'A' TO REMAIN - PROTECT IN PLACE 2 POC NO.1 EXISTING TAP,METER, BACKFLOW SIZE: 3/4-INCH PEAK DEMAND: 10 GPM AVAILABLE PRESSURE: 80 PSI+ 1 1A 4 A 4 2 EXISTING SLEEVES WITH MAINLINE AND WIRES INSTALLED WITH MASON STREET INFRASTRUCTURE PROJECT. COORDINATE WALL SLEEVES WITH GENERAL CONTRACTOR PRIOR TO CONSTRUCTION EXISTING TEMPORARY IRRIGATION INSTALLED FOR LOT 2 DURING MASON STREET INFRASTRUCTURE PROJECT SHALL BE REMOVED, INCLUDING MAINLINE, VALVES, HEADS, ETC. POC NO1. AND ASSOCIATED MAINLINE AND VALVES, AS NOTED, SHALL REMAIN, PROTECTED IN PLACE. A 'ULS1" A 1" A 'ULS1" 2A 1" A 'ULS1" 2 A 'ULS1" A 11" A 11"A 11" A 11" A 11" A 11" A 11" A 'ULS1" A 11" A 11" A 11" ELEC G SS SS SS SS SS SS SS D HYD S F ES EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. SYMBOL DESCRIPTION CONTRACTOR SHALL FIELD LOCATE EXISTING IRRIGATION MAINLINE, WIRES, AND GATE VALVE, AT THE APPROXIMATE LOCATION SHOWN. MAKE NEW MAINLINE CONNECTION AND ROUTE AS INDICATED. MAKE WIRE SPLICE WITH 3' COIL IN SEPARATE 6" ROUND VALVE BOX. CONTRACTOR SHALL FIELD LOCATE EXISTING IRRIGATION POC, INCLUDING BACKFLOW, MASTER VALVE, AND FLOW SENSOR, AT THE APPROX. LOCATION SHOWN. PROTECT IN PLACE. FIELD LOCATE EXISTING REMOTE CONTROL VALVE AND MAKE NEW LATERAL LINE CONNECTION AS INDICATED. ROUTE AS SHOWN. PROTECT IN PLACE AND REPAIR DAMAGES AS NECESSARY. CONTRACTOR SHALL FIELD LOCATE EXISTING MAINLINE AND REMOTE CONTROL VALVE FOR EXISTING RIGHT-OF-WAY SOD AT THE APPROX. LOCATION SHOWN. PROTECT IN PLACE AND REPAIR DAMAGES AS NECESSARY.  A   REFERENCE NOTES SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 2 Pr i n t e d O n : 2/ 1 4 / 2 0 2 4 1 1 : 1 0 A M Fi l e N a m e : IR - F T R E S C U E M I S S I O N . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 1 PIP SET 02/14/24 IRRIGATION PLAN PDP SUBMITTAL FORT COLLINS RESCUE MISSION FORT COLLINS, CO KR HJ/LO R22-030 IR1.2 NORTH 0 10 20 40 SCALE: 1"=20'-0" KEY MAP MATCHLINE - SEE SHEET IR1.1 MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com IR1.1 IR1.2 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 2 . 1 Pr i n t e d O n : 2/ 1 4 / 2 0 2 4 1 1 : 1 0 A M Fi l e N a m e : IR - F T R E S C U E M I S S I O N . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 ENGINEER ARCHITECT PLANNER/LANDSCAPE ARCHITECT NORTHERN ENGINEERING Andy Reese 301 N. Howes St., Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER DENVER RESCUE MISSION 6100 Smith Road Denver, CO 80216 p. 303.297.1815 SHOPWORKS ARCHITECTURE Chad Holtzinger 301 W 45th Ave. Denver, CO 80216 p. 303.433.4094 1 PIP SET 02/14/24 IRRIGATION DETAILS PDP SUBMITTAL FORT COLLINS RESCUE MISSION FORT COLLINS, CO KR HJ/LO R22-030 IR2.1 NORTH 0 10 20 40 SCALE: 1"=20'-0" MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com ISOLATION GATE VALVE ASSEMBLY2 TYPICAL TRENCHING DETAIL7 TYPICAL SLEEVING DETAIL6 24" min. TYPICAL GROUNDING (AT VALVE) ASSEMBLY5 QUICK COUPLING VALVE ASSEMBLY1 REMOTE CONTROL TURF VALVE ASSEMBLY3 REMOTE CONTROL DRIP VALVE ASSEMBLY8 6-INCH POP-UP SPRAY SPRINKLER ASSEMBLY4 SINGLE OUTLET EMITTER ASSEMBLY9 DRIP FLUSH CAP ASSEMBLY10