HomeMy WebLinkAboutFORT COLLINS RESCUE MISSION - FDP230022 - SUBMITTAL DOCUMENTS - ROUND 3 - Utility PlansN.
C
O
L
L
E
G
E
A
V
E
N
U
E
HICKORY STREET
CONIFER STREET
U
N
I
O
N
P
A
C
I
F
I
C
R
.
R
.
N.
C
O
L
L
E
G
E
A
V
E
N
U
E
HICKORY STREET
CONIFER STREET
U
N
I
O
N
P
A
C
I
F
I
C
R
.
R
.
CS1
CO
V
E
R
S
H
E
E
T
1
MARCH 2024 CONTACT INFORMATION
PROJECT TEAM:
VICINITY MAP
NORTH
FORT COLLINS RESCUE MISSION
PROJECT TEAM:
SHEET INDEX
FINAL UTILITY PLANS
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
A TRACT OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 2, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
PROJECT
LOCATION
Klara Rossouw
Ripley Design, Inc.
419 Canyon Avenue #200
Fort Collins, Colorado 80521
(970) 224-5828
Denver Rescue Mission
Josh Geppelt
6100 Smith Road
Denver, CO 80216
(303)291-4691
Northern Engineering Services, Inc.
Blaine Mathisen, PE
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
PLANNER/
LANDSCAPE ARCHITECT
OWNER/APPLICANT
SITE ENGINEER
GEOTECHNICAL ENGINEER
CTL Thompson, Inc.
Erin Beach, PE, PG
4396 Greenfield Drive
Windsor, Colorado 80550
(970) 545-3908
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
SITE SURVEYOR
E N G I N E E R N GI
EHTRON R N
E N G I N E E R N GI
EHTRON R N
PROJECT
LOCATION
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
Original Field Survery:
Northern Engineering
Project No. 1473-002
Date: April 2019
Additional Field Survey:
Northern Engineering
Project No. 1971-001
Date: October, 2022
BENCHMARK: #1-10
Elevation=4987.25 NAVD88
Northwest corner of College Ave. and Willox Lane on the southwest corner of a Storm Inlet.
BENCHMARK: #1-00
Elevation=4968.74 NAVD88
On a catch basin at the southeast corner of Vine Dr. and College Ave.
Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding
developments have used NGVD29 unadjusted datum (prior city of Fort Collins datum)
for their vertical datums.
if NGVD29 unadjusted datum (prior city of Fort Collins datum) is required for any
purpose, the following equation should be used: NGVD29 unadjusted datum (prior city
of Fort Collins datum) = NAVD88 - 3.17'
Basis of Bearings
The East line of the Northwest Quarter of Section 2 Township 7 North, Range 69 West of
the 6th P.M. as bearing South 00° 38' 02" West (assumed).
PROJECT BENCHMARKS:
FIELD SURVEY BY:
CTL Thompson, Inc
Geotechnical Investigation
Hibdon/Mason 24/7 Shelter
SWC Hibdon Court and Mason Street
Fort Collins, Colorado
Project No. FC10,520.000-125-R1
Date: October 25, 2022
SUBSURFACE EXPLORATION BY:
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
City of Fort Collins, CO
UTILITY PLAN APPROVAL
APPROVED:
CITY ENGINEER,APPROVED SHEETS DATE
APPROVED:
WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
STORMWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE
APPROVED:
TRAFFIC OPERATIONS,APPROVED SHEETS DATE
APPROVED:
ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
SHEET INDEX
1 CS1 COVER SHEET
2 CS2 GENERAL & CONSTRUCTION NOTES
3 CS3 EROSION CONTROL NOTES
SITE SHEETS
4 EX1 EXISTING CONDITIONS & DEMOLITION PLAN
5 HC1 HORIZONTAL CONTROL PLAN
GRADING SHEETS
6 OG1 OVERALL GRADING PLAN
7 - 10 G1 - G4 DETAILED GRADING PLAN
UTILITY SHEETS
11 U1 UTILITY PLAN
STORM DRAIN SHEETS
12 ST1 STORM DRAIN A PLAN & PROFILE
13 ST2 STORM A & A7 PLAN & PROFILE
14 ST3 STORM DRAIN B & C PLAN & PROFILE
15 ST4 COURTYARD DRAIN PLAN
16 ST5 STORM DRAIN R1, R2, & R3 STORM DRAIN PLAN
DETAIL SHEETS
17 D1 UTILITY DETAILS
18 - 21 D2 - D5 DRAINAGE DETAILS
22 D6 SITE DETAILS
EROSION CONTROL SHEETS
23 EC1 EROSION CONTROL PLAN
24 EC2 EROSION CONTROL DETAILS
DRAINAGE SHEETS
25 DR1 DRAINAGE EXHIBIT
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
GAS-----------------Xcel Energy-----------------------------Cory Thelen (970) 225-7843
ELECTRIC--------City of Fort Collins Light & Power--Rob Irish (970) 224-6167
CABLE-------------Comcast----------------------------------Marcus Petty (720) 275-0572
TELECOM--------Lumen-------------------------------------Brady Craddock (970) 342-3431
WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
CS2
CO
N
S
T
R
U
C
T
I
O
N
N
O
T
E
S
GE
N
E
R
A
L
&
2
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
ADDRESS POSTING & WAYFINDING
New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that
is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be
arabic numbers or alphabetical letters. Numbers shall not be spelled out. The address numerals for any commercial or industrial buildings shall be placed
at a height to be clearly visible from the street. They shall be a minimum of 8 inches in height unless distance from the street or other factors dictate larger
numbers. Refer to table 505.1.3 of the 2018 ifc as amended. The address numbers for one_ and two_family dwellings shall be a minimum of 4” in height
with a minimum ½” stroke and shall be posted on a contrasting background. If bronze or brass numerals are used, they shall only be posted on a black
background for visibility. Monument signs may be used in lieu of address numerals on the building as approved by the fire code official. Buildings, either
individually or part of a multi_ building complex, that have emergency access lanes on sides other than on the addressed street side, shall have the
address numbers and street name on each side that fronts the fire lane.
GENERAL NOTES
1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer
County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications,
or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer.
Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any
work shown in these plans.
4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as
beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins
Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer
hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and
demands which may arise from any errors and omissions contained in these plans.
5.All sanitary sewer, storm sewer, and water line construction, as well as power and other "dry" utility installations, shall conform to the City of Fort
Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the
Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The
Developer shall be responsible for unknown underground utilities.
7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning
excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located
by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the
responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility
crossings required.
9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to
modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished
in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any
disruption of any utility service as well as the utility companies.
11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider.
Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction
meeting may be required prior to commencement of any work.
12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary
sewer should be constructed prior to installation of the water lines and dry utilities.
13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water
Utility.
14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged
into a storm sewer, channel, irrigation ditch or any waters of the United States.
15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health,
Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
17.Certification of grading and drainage facilities must be completed by a registered engineer and submitted to the Stormwater Utility Department at least
two weeks prior to Stormwater Utility Department acceptance, or otherwise in accordance with the Development Agreement.
18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage,
whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City
of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19.All recommendations of the Final Drainage Report, dated February 14, 2024 by Northern Engineering Services, Inc., shall be followed and
implemented.
20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be
maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be
removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the
City of Fort Collins street inspector.
22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is
obtained, if applicable.
23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The
Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins -
221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of
Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the
Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper
installation.
24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is
complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the
results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may
use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be
prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of
base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report.
25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all
intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City
of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with
the City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the
purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property
lines and marked so as to reduce the excavation necessary for building connections.
27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads
within these districts.
28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the
Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal
requiring a permit.
30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security.
Refer to OSHA Publication 2226, Excavating and Trenching.
31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of
Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be
responsible for providing any and all traffic control devices as may be required by the construction activities.
32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic
Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign
then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local
street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the
Development.
34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction
activities on Sundays or holidays, unless there is prior written approval by the City of Fort Collins.
35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these
drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for
clarification, and annotate the dimension on the as-built record drawings.
37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications,
and a copy of any permits and extension agreements needed for the job.
38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the
Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the the
City of Fort Collins Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins
Engineer.
40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the
basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD88
CITY OF FORT COLLINS BENCHMARK 1-10
NORTHWEST CORNER OF COLLEGE AVE. AND WILLOX LANE ON THE SOUTHWEST CORNER OF A STORM INLET.
ELEVATION: 4987.25
CITY OF FORT COLLINS BENCHMARK 1-00
ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DR. AND COLLEGE AVE.
ELEVATION: 4968.74
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION
SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.17'
BASIS OF BEARINGS
THE EAST LINE OF THE NORTHWEST QUARTER OF SECTION 2 TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M. AS BEARING SOUTH
00° 38' 02" WEST (ASSUMED).
41.All stationing is based on centerline of roadways unless otherwise noted.
42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping,
structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the
Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of
the first Certificate of Occupancy.
43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with
the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved
with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may
be required. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer and/or the City of Fort Collins
Inspector at the time the cuts are made.
44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction,
or to the grades and condition as required by these plans.
45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and
workmanship defects for a minimum period of two years from the date of acceptance.
47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures
and pipes, for the following private streets: N.A.
48.Proposed Variances are listed as follows: N/A
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other
required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule,
construction plans, and erosion control report.
4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property
sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control
facilities shown herein.
5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the
area(s) required for immediate construction operations, and for the shortest practical period of time.
6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by
ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project
street rights-of-way shall remain exposed by land disturbing activity for more than fourteen (14) days before required temporary or permanent erosion
control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order
to ensure the continued performance of their intended function.
b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris
from all drainage infrastructure and other public facilities.
9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of
way, and make sure streets and walkways are cleaned at the end of each working day.
10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause
their release into any waters of the United States.
11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering,
and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before
turning the maintenance over to the City or Homeowners Association (HOA).
13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or
contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals,
oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper
containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and
located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material
will be removed and properly disposed of prior to the area being restored.
16. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever
measures are determined necessary, as directed by the City.
17. A Vehicle Tracking Control Pad shall be installed whenever it is necessary for construction equipment including but not limited to personal vehicles
exiting existing roadways. No earthen materials, i.e., stone, dirt, etc., shall be placed in the curb & gutter or roadway as a ramp to access temporary
stockpile(s), staging area(s), construction material(s), concrete washout area(s) and/or building site(s).
B. Street Improvement Notes
1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval,
prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be
submitted for approval prior to placement of any asphalt.
3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to
create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be
made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade
has been inspected and approved by the City of Fort Collins Engineer.
5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are
not allowed.
6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25,
Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be
made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new
asphalt overlay work.
7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per
the Right-of-Way Work Permit traffic control plan.
8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt.
Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth
section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The
entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle
weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h.
Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer,
shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24
hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector.
10.All public sidewalk, driveways, and ramps, existing or proposed, adjacent or within the site, need to meet ADA standards. If they currently do not, they will
need to be reconstructed so that they do meet current ADA standards as a part of this project.
11.Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due
to construction of this project, shall be replaced or restored to city of Fort Collins standards at the developer's expense prior to the acceptance of completed
improvements and/or prior to the issuance of the first certificate of occupancy.
C. Traffic Signing and Pavement Marking Construction Notes
1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction
Notes listed here.
2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5.All lane lines for concrete pavement should be epoxy paint.
6.Prior to permanent installation of traffic striping, symbols, and signs their placement shall be approved by the City of Fort Collins Traffic Engineer. The
developer shall place temporary tabs, tape or flags depicting alignment and location. Contact City of Fort COllins Traffic Operations at 970-221-6630
for field review.
7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10.All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified
during the field inspection must be corrected before the 2-year warranty period will begin.
12.The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13.Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins
Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen
condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements
of the 2-year warranty period for new construction (except fair wear on traffic markings).
15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
16.Contractor is responsible for removing all anchors, posts, signs and/or delineators in Construction area. Contractor may keep the signs, or call the City
Traffic Division to have them removed.
17.No “Reset” anchors, posts, signs, and/or delineators will be accepted.
18.All anchors, posts, signs, and/or delineators shall be new and be consistent
with the LCUASS criteria.
D. Storm Drainage Notes
1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
2.All recommendations of the Final Drainage Report, dated February 14, 2024 by Northern Engineering Services, Inc., shall be followed and
implemented.
3.Certification of grading and drainage facilities must be completed by a registered engineer and submitted to the Stormwater Utility Department at least two
weeks prior to Stormwater Utility Department acceptance, or otherwise in accordance with the Development Agreement.
4.See City of Fort Collins Stormwater Criteria Manual – Appendix F Construction Control Measures Standard Notes and Standard Erosion Control Notes.
E. Utility Notes
1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of
construction.
2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water
utility.
3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire.
4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The
HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections.
CS3
ER
O
S
I
O
N
C
O
N
T
R
O
L
N
O
T
E
S
3
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
F. INFILL AND REDEVELOPMENT NOTE
A.Despite everyone's best efforts, it is impossible to fully display subsurface information prior to excavation. This is especially true in areas
of infill and redevelopment. Unknown subsurface conditions can have cost and schedule implications. Prior to finalizing contract terms, it is
strongly recommended that the Owner and General Contractor have a candid discussion to formulate a strategy for dealing with such
circumstances when they arise. The process and procures should be in place prior to excavation. Allowances and contingencies can address the
cost implications, but additional measures are required to deal with scheduling and factors impacting sequence of work. The Architect,
Engineer(s), and Construction Surveyor should be made aware of the protocol for dealing with such unknown subsurface conditions prior to
starting work.
G. STANDARD EROSION CONTROL NOTES (CITY OF FORT COLLINS)
General Erosion Control Requirements
These notes are a summary for the legal requirements, that are set forth in the Fort Collins Stormwater
Criteria Manual (FCSCM), and that any conflict is resolved by the more stringent requirement controlling.
1.The Property Owner, Owner’s Representative, Developer, Design Engineer, General Contractor, Sub-contractors, or similar title for the
developing entity (here after referred to as the Developer) has provided these Erosion Control Materials in accordance with Erosion Control
Criteria set forth in the Manual as an attempt to identify erosion, sediment, and other potential pollutant sources associated with these
Construction Activities and preventing those pollutants from leaving the project site as an illicit discharge. Full City requirements and are
outlined and clarified in the Manual under Chapter 4: Construction Control Measures and should be used to identify and define what is
needed on a project.
2.The Developer shall make themselves thoroughly familiar with the provisions and the content of the specifications laid out in the Manual, the
Development Agreement, the Erosion Control Materials compiled for this project, and the following notes as all these materials are
applicable to this project.
3.The Developer shall implement and maintain Control Measures for all potential pollutants from the start of land disturbing activities until final
stabilization of the construction site.
4.The City Erosion Control Inspector shall be notified at least twenty-four (24) hours prior to the desired start of any construction activities on
this site to allow adequate time for on-site confirmation (initial inspection which can take up to two business days after receiving the request)
that the site is in fact protected from sediment and pollutants discharges off site. Please contact erosion@fcgov.com early to schedule those
Initial Erosion Control Inspections well in advance so that demolition, clearing, grubbing, tree removal, and scraping may begin without
delay. Failure to receive an on-site confirmation before construction activities commence is an automatic “Notice of Violation” and can result
in further enforcement actions.
5.The Developer shall proactively provide all appropriate Control Measures to prevent damage to adjacent downstream and leeward
properties. This includes but is not limited to: trees, shrubs, lawns, walks, pavements, roadways, structures, creeks, wetlands, streams,
rivers, and utilities that are not designed for removal, relocation, or replacement in the course of construction.
6.At all times the Developer shall be responsible to ensure adequate Control Measures are designed, selected, installed, maintain, repaired,
replaced, and ultimately removed in order to prevent and control erosion suspension, sediment transportation, and pollutant discharge as a
result of construction activities associated with this project.
7.All applicable Control Measures based upon the sequencing and/or phasing of the project shall be installed prior to those construction
activities commencing.
8.As dynamic conditions (due to the nature, timing, sequence, and phasing of construction) in the field may warrant Control Measures in
addition, or different, to what is shown on these plans, the Developer shall at all times be responsible to implement the Control Measures
that are most effective with the current state and progress of construction. The Developer shall implement whatever measures are
determined necessary, and/or as directed by the City Erosion Control Inspector. The Developer shall insure that all Erosion Control Plans
(Maps) or SWMP documents are updated to reflect the current site conditions, with updates being initialed and dated. These site inspections
and site condition updates shall be made available upon request by the City.
9.All listings, provisions, materials, procedures, activities, site work and the like articulated in this or other written site-specific documents
(Including but not limited to the erosion control reports, development agreements, landscape, and drainage materials) shall meet or exceed
the most restrictive language for City, County, State, and Federal regulations with regards to erosion, sediment, pollutant, and other pollution
source Control Measures. The Developer shall be responsible to comply with all of these aforementioned laws and regulations.
10.The Developer shall ensure that all appropriate permits (CDPS General Permit Stormwater Discharges Associated with Construction
Activity, Dewatering, Clean Water Act, Army Corps of Engineers’ 404 Wetlands Mitigation Permit, etc.) have been attained prior to the
relevant activity has begun. These permits or copies shall be made available upon request by the City.
11.The Developer shall furnish all conveniences and assistances to aid the Erosion Control Inspectors of materials, workmanship, records, and
self-inspections, etc. of the Control Measures involved in the construction activities.
12.The Developer shall request clarification of all apparent site construction issues that may arise due to inconsistencies in construction plans
for the site or site conditions around the selected Control Measures by contacting the Erosion Control Inspector. The Erosion Control
Inspector will not be responsible for any explanations, interpretations, or supplementary data provided by others.
13.All Control Measures shall be installed in accordance with the Manual.
14.The City reserves the right to require additional Control Measures as site conditions warrant, to the extent authorized by relevant legal
authority.
15.As with any construction standards, occasions may arise where the minimum erosion control standards are either inappropriate or cannot
be justified. In these cases, a variance to these standards may be applied for pursuant to the terms, conditions, and procedures of the
Manual.
16.Inspection. The contractor shall inspect site pollutant sources and implement Control Measures at a minimum of once every two weeks
during construction and within 24 hours following a precipitation event. Documentation of each inspection shall be recorded and retained by
the contractor.
17.All temporary Control Measures shall be cleaned, repaired, or reconstructed as necessary in order to assure continual performance of their
intended function. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and
location so as not to cause their release into any drainage way.
18.Any Control Measure may be substituted for another standard Control Measure so long as that Control Measure is equal to, or of greater
protection than the original Control Measure that was to be used in that location. (ex. silt fence, for wattles, or for compact berms) Wattle
alone on commercial construction sites have shown to be an ineffective substitute for silt fence or compact berms unless it is accompanied
by a construction fence to prevent vehicle traffic.
19.Any implementation or replacement of existing Control Measures for a non-standard control, or alternative Control Measure, shall require
the review and acceptance by the City erosion control staff before the measure will be allowed to be used on this project. These Control
Measures’ details shall be submitted, reviewed and accepted to be in accordance with the Erosion Control Criteria based upon the
functionality and effectiveness in accordance with sound engineering and hydrological practices
Land disturbance, Stockpiles, and Storage of Soils
20.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. Off road staging areas or stockpiles must be
preapproved by the City. Disturbances beyond these limits will be restored to original condition.
21.Pre-disturbance vegetation shall be identified, protected, and retained wherever possible. Removal or disturbance of existing vegetation
shall be limited to the area required for immediate construction operations, and for the shortest practical period of time. This should include
sequencing and phasing construction activities in a way so that the soil is not exposed for long periods of time by schedule or limit grading
to small areas. This should also include when practical advancing the schedule on stabilization activities such that landscaping takes place
shortly if not immediately after grading has occurred. Vegetation efforts shall start as soon as possible to return the site to a stabilized
condition. Sensitive areas should avoid clearing and grading activities as much possible.
22.All exposed soils or disturbed areas are considered a potential pollutant and shall have Control Measures implemented on the site to
prevent materials from leaving the site.
23.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened
condition at all times by equipment tracking, scarifying or disking the surface on a contour with a 2 to 4 inch minimum variation in soil
surface until mulch, vegetation, and/or other permanent erosion control is installed.
24.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport through the use of surface
roughening, watering, and down gradient perimeter controls. All soil stockpiles shall be protected from sediment transport by wind in
accordance with Municipal Code §12-150. All stockpiles shall be flattened to meet grade or removed from site as soon as practical, and no
later than the completion of construction activities or abandonment of the project. All off-site stockpile storage locations in City limits shall
have a stockpile permit from the City Engineering Department prior to using the area to store material. If frequent access from hardscape to
the stockpile is needed a structural tracking Control Measure shall be implemented.
25.All required Control Measures shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc.). All of the required
erosion Control Measures must be installed at the appropriate time in the construction sequence as indicated in the approved project
schedule, construction plans, and erosion control report.
26.All inlets, curb-cuts, culverts, and other storm sewer infrastructure which could be potentially impacted by construction activities shall be
protected with Control Measures. Material accumulated from this Control Measure shall be promptly removed and in cases where the
protection has failed, the pipes shall be thoroughly cleaned out.
27.All streams, stream corridors, buffers, woodlands, wetlands, or other sensitive areas shall be protected from impact by any construction
activity through the use of Control Measures.
28.All exposed dirt shall have perimeter control. Any perimeter controls that drain off or has the ability to be tracked onto the nearby hardscape
shall have some form of effective sediment control as the, or as part of the, perimeter control.
29.All exposed slopes should be protected. All exposed steep slopes (Steeper than 3:1 H:V) shall be protected from erosion and sediment
transport through use of Control Measures.
30.No soils shall remain exposed by land disturbing activity for more than thirty (30) days after activity has ceased before required temporary
seeding or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed. This is not just limited to projects that are abandoned;
this includes any project that is temporarily halted and no immediate activity is to resume within the next thirty (30) days, unless otherwise
approved by the City Erosion Control Inspector. During a season when seeding does not produce vegetative cover, another temporary
erosion control shall be implemented with or until temporary seeding or permanent erosion control can be performed.
31.All individual lots shall have effective sediment controls located on the street side and any down gradient side. Typically most lots drain to
the front yet on those cases where houses are along a pond or drainage swale have the lot drain in a different direction than the street,
those individual lots will need protection on that down gradient side to prevent sediment from leaving the lot. See the Individual Lot Details
for further clarification.
Vehicle Tracking
32.At all points where vehicles exit or leave the exposed dirt area on to a hardscape or semi hardscape (concrete, asphalt, road base, etc.)
shall have installed at least one structural tracking Control Measure to prevent vehicle tracking. All areas not protected by an adequate
perimeter control shall be considered a point where vehicles exit the site. Access points should be limited to as few entrances as possible
(All perimeter areas shall be protected from tracking activities).
33.In all areas that the structural tracking Control Measures fail to prevent vehicle tracking, collection and proper disposal of that material is
required. All inlets located near access points and affected by tracking activities shall be prevented from the introduction of sediment into the
drainage system.
34.City Municipal Code §20-62, among other things, prohibits the tracking, dropping, or depositing of soils or any other material onto city
streets by or from any source. City Municipal Code, §26-498, among other things, prohibits the discharge of pollutants on public or private
property if there is a significant potential for migration of such pollutant. Therefore, all tracked or deposited materials (intentional or
inadvertent) are not permitted to remain on the street or gutter and shall be removed and legally disposed of by the Developer in a timely
and immediate manner. Dirt ramps installed in the curb-lines are not exempt to these sections of code and shall not be permitted in the
street right of way (public or private).
35.If repeated deposit of material occurs on a site, additional structural tracking controls may be required of the Developer by the City Erosion
Control Inspector.
Loading and Unloading Operations
36.The Developer shall apply Control Measure to limit traffic (site worker or public) impacts and proactively locate material delivered to the site
in close proximity to the work area or immediately incorporated in the construction to limit operational impacts to disturbed areas, vehicle
tracking, and sediment deposition that could impact water quality.
Outdoor Storage or Construction Site Materials, Building Materials, Fertilizers, and Chemicals
37.Any materials of a non-polluting nature (steel, rock, brick, lumber, etc.) shall be inspected for any residue coming off the material during
routine inspection and will generally be located where practical at least fifty (50) feet from any permanent or interim drainage ways.
38.Any high environmental impact pollutant materials that have a high likelihood to result in discharge when in contact with stormwater
(lubricants, fuels, paints, solvents, detergents, fertilizers, chemical sprays, bags of cement mix, etc.) should not be kept on site where
practical. When not practical, they should be stored inside (vehicle, trailer, connex, building, etc.) and out of contact with stormwater or
stormwater runoff. Where not available, they shall be stored outside in a raised (high spots or on pallets), covered (plastic or tarped), and
sealed (leak proof container) in secondary containment location. The secondary containment or other Control Measure shall be adequately
sized, located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage ways and shall be
monitored as part of the routine inspections.
Vehicle and equipment maintenance and fueling
39.Parking, refueling, and maintenance of vehicles and equipment should be limited in one area of the site to minimize possible spills and fuel
storage areas. This area shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or
drainage ways and shall be monitored as part of the routine inspections. All areas shall keep spill kits and supplies close.
Significant Dust or Particulate generating Process
40.The property must be actively preventing the emission of fugitive dust at all times during construction and vegetation activities. All land
disturbing activities that result in fugitive dust shall be in accordance with Municipal Code §12-150 to reduce the impacts to adjacent
properties and community health. All required practices shall be implemented and additional ones shall be followed. These practices include
watering the sites and discontinuing construction activities until the wind subsides as determined by any City Inspectors. Concrete truck /
equipment washing, including the concrete truck chute and associated fixtures and equipment
41.All concrete and equipment washing shall use structural Control Measures appropriate to the volume of wash and frequency of use. These
Control Measures shall be located, where practical, at least fifty (50) feet from any permanent or interim stormwater structures or drainage
ways and shall be monitored as part of the routine inspections. These areas shall be clearly identified and protected from any wash from
leaving the Control Measure. If frequent access from hardscape to the Control Measure is to occur, a structural tracking Control Measure
shall be implemented. These Control Measures shall be frequently cleaned out.
42.The Developer is responsible for ensuring washing activity is taking place at the appropriate Control Measure and site workers are not
washing or dumping wash water on to the dirt or other uncontrolled locations.
Dedicated Asphalt and concrete batch plants
43.Dedicated asphalt and concrete batch plants are not acceptable on construction sites within the City of Fort Collins without an expressed
written request and plan to reduce pollutants associated with that type of activity and approval by the City of Fort Collins specifically the
Erosion Control Inspector. The Developer shall inform the erosion control inspection staff of any dedicated asphalt, or concrete batch plants
that is to be used on site.
Concrete Saw Cutting Materials
44.Saw cutting material shall be in accordance with Municipal Code §12-150 for air emissions and all water applications to the saw cutting shall
prevent material from leaving the immediate site and collected. These cutting locations, once dried, shall be swept and scraped of all
material and shall have proper and legal disposal.
Waste Materials Storage and Sanitary Facilities
45.Trash, debris, material salvage, and/or recycling areas shall be, where practical, at least fifty (50) feet from any permanent or interim
stormwater structures or drainage ways and shall be monitored as part of the routine inspections. These facilities should be located out of
the wind and covered as able. Where not able to cover, locating said areas on the side of other structures to reduce exposure to winds, and
follow maximum loading guidelines as marked on the container. The Developer is required to practice good housekeeping to keep the
construction site free of litter, construction debris, and leaking containers.
46.Sanitary facilities shall be prevented from tipping through the use of anchoring to the ground or lashing to a stabilized structure. These
facilities shall also be located as far as practical from an inlet, curb cut, drainage swale or other drainage conveyances to prevent material
transport from leaving the local area. This consists of the facility being located, where practical, at least fifty (50) feet from any permanent or
interim drainage ways.
Other Site Operations and Potential Spill Areas
47.Spills: For those minor spills that; are less than the State’s reportable quantity for spills, stay within the permitted area, and in no way
threaten any stormwater conveyance, notify the City of Fort Collins Utilities by email at erosion@fcgov.com or phone (970) 817-4770. For
any significant, major, or hazardous spills, notify the City of Fort Collins Utilities by phone only after Emergency Response (911) has been
notified and is on route, County Health Department (LCDHE) has been notified through Larimer County Sheriff Dispatch (970) 416-1985,
and the State Spill Hotline Incident Reporting have been contacted 1-877-518-5608. Written documentation shall be provided to the City
within 5 days of the event. All spills shall be cleaned up immediately.
48.Selection of “plastic welded” erosion control blankets shall not be used in areas that wildlife, such as snakes, are likely to be located as
these have proven to cause entrapment issues.
Final stabilization and project completion
49.Any stormwater facilities used as a temporary Control Measure will be restored and storm sewer lines will be cleaned upon completion of
the project and before turning the maintenance over to the Owner, Homeowners Association (HOA), or other party responsible for long term
maintenance of those facility.
50.All final stabilization specifications shall be done in accordance with the Manual, Chapter 4: Construction Control Measures.
51.All disturbed areas designed to be vegetated shall be amended, seeded & mulched, or landscaped as specified in the landscape plans and
per City of Fort Collins standards within 14 working days of final grading.
52.Soil in all vegetated (landscaped or seeded) areas, including parkways and medians shall comply with all requirements set forth in Sections
12-130 through 12-132 of the City Municipal Code, as well as Section 3.8.21 for the City Land Use Code.
53.All seeding shall refer to landscaping plans or the Erosion Control Plans for species mixture and application rates and depths requirements.
54.All seed shall be drilled where practical to a depth based upon the seed type. Broadcast seeding shall be applied at double the rate as
prescribed for drill seeding and shall be lightly hand raked after application. Hydroseeding may be substituted for drill seeding on slopes
steeper than 3(H):1(V) or on other areas not practical to drill seed and crimp and mulch. All hydroseeding must be conducted as two
separate processes of seeding and tackification.
55.All seeded areas must be mulched within twenty-four (24) after planting. All mulch shall be mechanically crimped and or adequately applied
tackifier. The use of crimped mulch or tackifier may require multiple re-applications if not properly installed or have weathered or degraded
before vegetation has been established. Areas of embankments having slopes greater than or equal to 3H:1V shall be stabilized with an
erosion mat or approved equal to ensure seed will be able to germinate on the steep slopes. During a season when seeding doesnot
produce vegetative cover, another temporary erosion control shall be implemented along with, or until, temporary seeding or permanent
erosion control can be performed.
56.The Developer shall warranty and maintain all vegetative measures for two growing seasons after installation or until seventy percent (70%)
vegetative cover has been established, whichever is longer and meets all the Criteria outlined in the Fort Collins Stormwater Criteria Manual
Chapter 4: Construction Control Measures.
57.The Developer shall maintain, monitor, repair, and replace any and all applicable Control Measures until final stabilization has been
obtained. All Control Measures must remain until such time as all upstream contributing pollutant sources have been vegetated or removed
from the site. When any Control Measure is removed, the Developer shall be responsible for the cleanup and removal of all sediment and
debris from that Control Measure. At the point at which the site has been deemed stabilized and verified by City Erosion Control Inspector,
all temporary Control Measures can then be fully removed. All measures shall be removed within 30 days after final stabilization is achieved.
58.The responsible party shall maintain and keep current all payments or related forms of security for the Erosion Control Escrow until 1)
stabilization has been reached and 2) all Control Measures and/or BMPs have sediment materials collected and the Control Measure
removed from the site. At that time the site will be considered completed and any remaining Erosion Control Escrow shall be returned to the
appropriate parties.
ELEC
F
CTV
CTV CTV CTV CTV CTV
OHU OHU OHU OHU
CTV
X X X X
X X X X X X X
CTV
G G G
G G G G G G
SS SS SS SS SS SS
HY D
S
FE S
FE S
XX
X
X
X
X
W W W W W W W
W W
SSSSSS
S
S
S
S
S
S
W W
S
8" W
S
E E E E E E E E E E E E E E E E E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
I
UDUDUDUDUDUDUDUDUDUDUDUDUD
UD
UD
UD
U
D
UD
UD
U
D
U
D
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
12" SS
1
2
"
S
S
12" SS
1
2
"
S
S
1
2
"
S
S
8
"
W
8
"
W
8
"
W
8" W
8" W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8"
W
8"
W
8"
W
8"
W
8"
W
12" SS 12" SS
EEEEEEE
E
E
E
T
F
SC
E
V
W
F
N
M
A
S
O
N
S
T
R
E
E
T
WANKIER LANCE
1401 N. COLLEGE AVENUE
FORT COLLINS, CO
WOOD RONALD G/ JENNIFER
L/ WILLARD E
122 HIBDON COURT
FORT COLLINS, CO
THOMPSON PROPERTIES LLC
1319 N. COLLEGE AVENUE
FORT COLLINS, CO
EXISTING FIRE
HYDRANT
PLANNED NATURAL
HABITAT BUFFER ZONE
SEE NOTE 6
LOT LINE
HICKORY REGIONAL
DETENTION POND
LOT 1
LOT 2
LOT 3
PLANNED
42'' FL-FL
PLANNED FIRE
HYDRANT
SEE NOTE 6
PLANNED 3/4"
IRRIGATION
METER PIT
PLANNED 2" WATER
METER VAULT
SEE NOTE 6
PLANNED 3 PHASE
ELECTRIC BOX
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED 6" PVC
FIRE SERVICE
SEE NOTE 6
PLANNED 24"
HP STORM
SEE NOTE 6
PLANNED 6" PVC
SANITARY SERVICE
SEE NOTE 6
HIBDON COURT
PLANNED 4' SIDEWALK
CHASE AND CURB CUT
SEE NOTE 6
PLANNED 2' CONCRETE PAN
206-LF TO BE REMOVED
PLANNED
50'' FL-FL
PLANNED GRASS
LINED SWALE
TO BE REMOVED
SEE NOTE 6
PLANNED 12" SANITARY
SEWER
SEE NOTE 6
PLANNED 8"
WATER LINE
SEE NOTE 6
EXISTING 8" WATER
LINE
EXISTING
SANITARY SEWER
PLANNED 5' SIDEWALK
10' UTILITY
EASEMENT
BK1658 PG746
10' UTILITY EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
EXISTING 12"
STORM DRAIN
PLANNED 3 PHASE
ELECTRIC BOX
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED GAS LINE
SEE NOTE 6
PLANNED ELECTRIC LINE
SEE NOTE 6
GRATITUDE LLC
1303 N. COLLEGE AVENUE
FORT COLLINS, CO
PLANNED 24" HDPE STORM
SEE NOTE 6
72-LF TO REMAIN
PLANNED TURF
REINFORCEMENT MAT
SEE NOTE 6
PLANNED TURF
REINFORCEMENT MAT
SEE NOTE 6
PLANNED DRAINAGE
EASEMENT
SEE NOTE 6
PLANNED CONNECTION VAULT
(CITY OF FORT COLLINS)
SEE NOTE 6
TRACT A
PLANNED STREET LIGHT
AND TRANSFORMER
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED STREET LIGHT
AND TRANSFORMER
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED STREET LIGHT
AND TRANSFORMER
(CITY OF FORT COLLINS)
SEE NOTE 6
3' POWER LINE EASEMENT TO
CITY OF FORT COLLINS
BK 1475 PG 941
TO BE VACATED BY SEPARATE
DOCUMENT
45' ROW
BK 1743 PG 632
PLANNED
71' ROW
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
20' EMERGENCY ACCESS
EASEMENT PER MASON STREET
INFRASTRUCTURE PLAT
10' UTILITY EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
9' UTILITY EASEMENT PER
MASON STREET
INFRASTRUCTURE PLAT
30' STORMWATER & UTILITY
EASEMENT PER MASON
STREET INFRASTRUCTURE
PLAT
24' EMERGENCY ACCESS
EASEMENT PER MASON
STREET INFRASTRUCTURE
PLAT
PLANNED 4" SANITARY
SERVICE SEE NOTE 6
///////
PLANNED 24" HDPE STORM
SEE NOTE 6
12-LF & NYLOPLAST BASIN
TO BE REMOVED
PLANNED STREET LIGHT
AND TRANSFORMER
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED 6' CONCRETE SIDEWALK
7.5-LF TO BE REMOVED
6" CURB
3-LF TO BE REMOVED
EX1
DE
M
O
L
I
T
I
O
N
P
L
A
N
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
&
4
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
NOTES:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
8.REFER TO LANDSCAPE PLANS FOR TREE PROTECTION AND MITIGATION.
EXISTING OVERHEAD UTILITY OHE
EXISTING ASPHALT/CONCRETE (TO BE REMOVED)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
Original Field Survey:
Northern Engineering
Project No. 1473-002
Date: April 2019
Additional Field Survey:
Northern Engineering
Project No. 1971-001
Date: October, 2022
CTL Thompson, Inc
Geotechnical Investigation
Hibdon/Mason 24/7 Shelter
SWC Hibdon Court and Mason Street
Fort Collins, Colorado
Project No. FC10,520.000-125-R1
Date: November 20, 2023
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
TREE PROTECTION NOTES:
1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE
PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.
2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A
QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE.
3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND
REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE
REQUIRED BY CODE.
4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH
BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX
(6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT
OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.
5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL
OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY
OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD
RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH
TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF
FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING
CLEARED.
8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6)
INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF
TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM
TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:
9.ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A
SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA.
EL
E
C
CT
V
X
X
X
X
X
X
X
G
G
G
G
G
G
XX
X
X
SS
SS
SS
SS
SS
SS
EV
U
D
U
D
SC
T
F
UD
UD
UD
UD
G
E
N
UD
N MA
S
O
N
S
T
R
E
E
T
HI
B
D
O
N
C
O
U
R
T
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
LOT 2
LOT 3
PLANNED
42'' FL-FL
PLANNED
50'' FL-FL
HICKORY REGIONAL
DETENTION POND
LOT 1
RAIN
GARDEN 1
PLANNED
71' ROW
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
RAIN
GARDEN 2
6'
S
I
D
E
W
A
L
K
EX. 6'
S
I
D
E
W
A
L
K
58' FL-FL
41' FL-FL
17'
FL-FL
20' FL-FL
24' DRIVE
AISLE
24' DRIVE
AISLE
17'9'EX. 6' SIDEWALK
4' WALK w/ 6" RIBBON CURB
6'
S
I
D
E
W
A
L
K
20' DRIVE
AISLE
17'
9'
20' FL-FL
20' EMERGENCY
ACCESS EASEMENT
PER MASON STREET
INFRASTRUCTURE
PLAT
8'
8'
9'
17'
10' UTILITY EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
6
'
S
I
D
E
W
A
L
K
±38' DRAINAGE
EASEMENT PER
MASON STREET
INFRASTRUCTURE
PLAT
9' UTIL
I
T
Y
E
A
S
E
M
E
N
T
9' UT
I
L
I
T
Y
E
A
S
E
M
E
N
T
30' STORMWATER
& UTILITY
EASEMENT PER
MASON STREET
INFRASTRUCTURE
PLAT
R5'
R5'
R3'
R3'
R3'
R3'
R25'
R45'
3
2
LOT LINE
PLANNED 4' SIDEWALK
CHASE AND CURB CUT
SEE NOTE 6
2
2
2
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
2
2
1
1
2
2
22
1
2
2
2
2
2
2
2
2
2
2
2
2
1
1
CONCRETE RUNDOWN
AND FOREBAY 1-1
CONCRETE RUNDOWN
AND FOREBAY 1-2
CONCRETE RUNDOWN
AND FOREBAY 2-1
4' CURB CUT
4' CURB CUT
FENCE
(SEE LANDSCAPING PLANS)
CONCRETE
EMERGENCY
SPILLWAY
CONCRETE
EMERGENCY
SPILLWAY
A
A
6" RIBBON
CURB
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
AREA INLET
(TYP.)
AREA INLET
(TYP.)
T
T
1
T1
T
B
B
D
C
GATE
(SEE LANDSCAPING PLANS)
GATE
(SEE LANDSCAPING PLANS)
AREA INLET
(TYP.)
PLANNED
"15 MINUTE PARKING" SIGN
SEE NOTE 6
PLANNED
"NO PARKING" SIGN
SEE NOTE 16
B
B
5' WALK
5' WALK
5' WALK
5' WALK
D
D
P
P
2
2
CONCRETE
FOREBAY 2-2
CONCRETE
FOREBAY 2-3
GATE
(SEE LANDSCAPING PLANS)
RAILINGS
(SEE LANDSCAPING PLANS)
PLANNED
"15 MINUTE PARKING" SIGN
SEE NOTE 6
RAILINGS
(SEE LANDSCAPING
PLANS)
MONUMENT SIGN
(SEE ARCH. PLANS)
CONCRETE
FOREBAY 1-3
CONCRETE
FOREBAY 1-4
R25'
R25'
5' CRUSHER FINES
WALK WITH 6"
RIBBON CURB
AREA INLET
(TYP.)
6' SIDEWALK
AREA INLET
(TYP.)
TRASH
ENCLOSURES
(SEE LANDSCAPE
PLANS)
SHADE STRUCTURE COLUMNS, TYP.
(SEE LANDSCAPING PLANS)
1' SIDEWALK CHASE
SEE DETAIL 206 SHT 19
1' SIDEWALK CHASE & CHANNEL
SEE DETAIL 205 SHEET 19
10'
RETAINING WALL
SEE LANDSCAPING
PLANS
B
T
4' WALK
w
/
6
"
R
I
B
B
O
N
C
U
R
B
4' WA
L
K
w
/
6
"
R
I
B
B
O
N
C
U
R
B
8'33.6' CONCRETE
RETAINING WALL
HC1
HO
R
I
Z
O
N
T
A
L
C
O
N
T
R
O
L
P
L
A
N
5
NORTH
( IN FEET )
1 inch = ft.
Feet02020
20
40 60
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
1
2
3
T
30" VERTICAL INFLOW CURB & GUTTER
18" VERTICAL INFLOW CURB & GUTTER
CURB & GUTTER TRANSITION
1.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK.
2.ATTACHED WALK WIDTHS ARE FROM FLOW LINE.
3.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF
PLAN LOCATION.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE
PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO
THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL
INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE
AMENITIES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND
PROJECT SPECIFICATION MANUAL.
10.HEAVY DUTY PAVING WITHIN THE EMERGENCY ACCESS EASEMENTS SHALL BE
CAPABLE OF SUPPORTING 80,000 LBS. SEE DETAIL ON SHEET 22 FOR ADDITIONAL
INFORMATION.
18" VERTICAL OUTFALL CURB & GUTTER
EASEMENTS
NOTES:
PROPOSED INFLOW CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
PROPOSED OUTFALL CURB & GUTTER
X' CONCRETE PAN
LEGEND:
PROPOSED LOT LINE
EXISTING ROW
PROPOSED ROW
LIGHT DUTY PAVING
CONCRETE FLATWORK
RESERVED
PARKING
B
CONCRETE PAVING
P
FIRE LANE
X
A
P0TS
C
HEAVY DUTY PAVING
SITE SIGN LEGEND
ARTIFICIAL TURF
CRUSHER FINES (ADA ACCEPTABLE MATERIAL)
430" VERTICAL OUTFALL CURB & GUTTER
P
D
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
NO OUTLET
P0TS
D
PROPOSED DOWNSPOUT DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
U
D
U
D
SC
T
F
UD
UD
UD
UD
G
E
N
UD
X
X
X
X
X
X
X
X
G
G
G
G
G
XX
SS
SS
SS
SS
SS
SS
SS
UD
EV
N MAS
O
N
S
T
R
E
E
T
LOT 2
LOT 3
PLANNED
42'' FL-FL
HI
B
D
O
N
C
O
U
R
T
PLANNED
50'' FL-FL
HICKORY REGIONAL
DETENTION POND
LOT 1
PLANNED
71' ROW
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
RAIN GARDEN 2
6
.
4
%
6
.
6
%
0.
8
%
1.9
%
3
.
3
%
1.
7
%
2
.
3
%
2.2
%
1.9%
3.2
%
2.7%
2
.
5
%
2
.
2
%
3.2
%
2.7%
1.5%
1.7
%
1.5%
1.8%
1.5%
3
.
8
%
2.4%
6.
0
%
5.
5
%
4:1
7:1
4:1
4:1
5:1
8:1
8:1
2.6%
2.0
%
2.0%
2.0%
2.6%
5.0%
1.
6
%
3.
9
%
1
.
3
%
6.8
%
4
.
0
%
2
.
7
%
15.1%
6.6%
11.3%
7.6%
11.5%
1.0%
2.1%
1.
4
%
8.1%
11
.
5
%
7.
2
%
1.2%
2.
0
%
0.6%2.0%
0
.
1
%
0
.
4
%
1
.
1
%
1
.
1
%
1.7%
6
.
0
%
9.3%
9.6%
2.9%
PLANNED 4' SIDEWALK
CHASE AND CURB CUT
SEE NOTE 6
CONCRETE RUNDOWN
AND FOREBAY
CONCRETE RUNDOWN
AND FOREBAY
CONCRETE RUNDOWN
AND FOREBAY
4' CURB CUT
4' CURB CUT
CONCRETE
EMERGENCY
SPILLWAY
CONCRETE
EMERGENCY
SPILLWAY
TRASH ENCLOSURE
(SEE LANDSCAPE
PLANS)
EX. 6'
S
I
D
E
W
A
L
K
EX. 6' SIDEWALK
24' EMERGENCY ACCESS
EASEMENT PER MASON
STREET INFRASTRUCTURE
PLAT
4' WALK w
/
6
"
R
I
B
B
O
N
C
U
R
B
30' STORMWATER
& UTILITY
EASEMENT PER
MASON STREET
INFRASTRUCTURE
PLAT
0.8
%
9:1
5.2%
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
9' UTILITY
E
A
S
E
M
E
N
T
2.2%
3 - 5"/11"
RISERS
4 - 6.5"/11"
RISERS
1
.
7
%
RAIN GARDEN 1
RAILING (TYP.)
SEE LANDSCAPING PLANS
DRAINAGE
EASEMENT PER
MASON STREET
INFRASTRUCTURE
PLAT
2.0%
2.4%
2.
3
%
2.
0
%
2.0
%
2.3
%
2.
0
%
STORM DRAIN LINE A
SEE SHEET ST1
STORM DRAIN LINE B
SEE SHEET ST3
STORM DRAIN LINE C
SEE SHEET ST3
COURTYARD DRAINS
SEE SHEET ST4
STORM DRAIN LINE R1
SEE SHEET ST5
STORM DRAIN LINE R2
SEE SHEET ST5
STORM DRAIN LINE R3
SEE SHEET ST5
4.
0
%
5.1%
1.
6
%
2
.
5
%
2
.
8
%
4' WA
L
K
w
/
6
"
R
I
B
B
O
N
C
U
R
B
4' WALK w/ 6" RIBBON CURB
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
OG1
OV
E
R
A
L
L
G
R
A
D
I
N
G
P
L
A
N
6
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet02020
20
40 60
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.FOREBAYS SHALL BE CONSTRUCTED ON COMPACTED SOIL AND NOT RAIN GARDEN
MEDIA. SEE DETAIL 400 SHEET 20 FOR MORE INFORMATION.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
UD
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
CT
V
G
G
G
G
G
G
G
G
G
SS
H
YD
S
SS
SS
SS
SS
SS
SS
SS
8"
W
8"
W
8"
W
8"
W
8"
W
E
E
E
E
E
E
E
E
E
EEEEEEEEEEEEEEEEEE
G G G G G G G G G G G G G G G G G
G
G
G
G
G
G
G
G
12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS 12" SS
12" SS
12" SS
12" SS
12" SS
12" SS
12" SS
12" SS
8" W
8" W
8" W
8" W
8" W
8" W
8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
E
E
E
E
E
E
E
E
E
E
E
E
TF
E
E
E
E
E
E
E
E
12" SS
W F
DS
DS
DS
LOT 2
LOT 3
PLANNED
42'' FL-FL
HI
B
D
O
N
C
O
U
R
T
PLANNED
71' ROW
FFE=84.50
83.
9
6
8
3
.
3
4
84.50
8
4
.
5
0
83
.
3
2
83
.
3
2
82
.
2
5
8
1
.
8
6
81.93
8
0
.
3
7
8
0
.
3
5
79.69
7
9
.
2
7
79.20
79.17
7
9
.
6
3
7
9
.
6
9
79.59
79.42
8
3
.
8
3
8
3
.
1
8
83.1880.37
80.86
84.23
82.56
10.1%
2.6%
2.2%
2.0%
4.4%
3.
9
%
3.
9
%
2.0%
0
.
6
%
0
.
5
%
1.7%
6
.
0
%
9.3%
9.6%
6" RIBBON
CURB
EX. 6' SIDEWALK
4' WALK w/ 6" RIBBON CURB
82.1
0
82
.
7
5
79.35
83
.
9
2
83.80
83.73
83.5
7
84
.
1
0
8
3
.
0
4
83.7
0
5.2%
9' UTILITY
E
A
S
E
M
E
N
T
4.6%
1
.
7
%
8
0
.
8
6
FFE=84.50
2.0%
7
9
.
1
5
7
8
.
8
9
79.07
0
.
5
%
0.
5
%
4.6%
79.68
79.60
8
0
.
2
0
80.3
2
79.80
80.
0
0
TB
C
80.
1
5
8.
2
%
2.0%
7.
2
%
79.72
79.52
FL
N MASON STREET
83.92
83.85
83.49
83.59
6'
W
A
L
K
12.1%
1.9%
1.9
%0.
5
%
4.6%
2.0%
6" HDPE PIPE CONNECTION
FROM DOWNSPOUT TO
SIDEWALK CHASE
1.
6
%
1
.
9
%
84.23
2
.
8
%
2
.
8
%
1.4%
2.0%
0.
6
%
2.
1
%
83.3
4
83.16
1.6%
2.4%
2.
4
%
5.0%
1
.
6
%
2
.
8
%
1
.
6
%
82.3
5
6
.
2
%
5
.
1
%
8
.
3
%
1' SIDEWALK CHASE
SEE DETAIL 206 SHT 19
1' SIDEWALK CHASE & CHANNEL
SEE DETAIL 205 SHEET 19
1.8%
82.8
1
83
.
5
2
8
0
.
3
6
81.62
81.50
82.0
5
82.1
0
(8
1
.
5
5
)
80.26
1.0%
79
.
5
8
FL
8
0
.
0
6
F
L
83.4
9
83
.
5
0
BEGIN CONCRETE
RETAINING WALL
N:137732.81
E:194210.27
82.6
1
BIKE RACKS
(TYP.)
2
.
0
%
3.
4
%
5.
0
%
2
.
0
%
82.2
0
SW
81.
6
2
FL
???
7
9
.
8
6
7
9
.
8
0
80
.
3
2
END CONCRETE
RETAINING WALL
0.4%
4' WALK
w
/
6
"
RIBBON C
U
R
B
3
2
1 G1
DE
T
A
I
L
E
D
G
R
A
D
I
N
G
P
L
A
N
7
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.FOREBAYS SHALL BE CONSTRUCTED ON COMPACTED SOIL AND NOT RAIN GARDEN
MEDIA. SEE DETAIL 400 SHEET 20 FOR MORE INFORMATION.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
UD
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G2
MATCH LINE - SEE SHEETG3
G3 G1
G2G4
DOWNSPOUT LEGEND
1
2PROVIDE CONCRETE CHANNEL FROM DOWNSPOUT TO CHASE.
PROVIDE 1/2" EXPANSION JOINT AT BUILDING FACE
3
PIPE CONNECTION TO STORM DRAIN (SEE SHEET 20)
PROVIDE PIPED DOWNSPOUT CONNECTION TO CHASE
4STORM CONNECTION TO BUILDING (SEE M/E/P PLANS)
5TYPICAL DOWNSPOUT (SEE ARCH. PLANS)
1.COORDINATE DOWNSPOUT LOCATIONS AND ELEVATION WITH ARCHITECTURE
PLANS PRIOR TO CONSTRUCTION.
CT
V
X
X
X
X
S
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
I
12" SS
12" SS
12" SS
12" S
S
12" S
S
12" S
S
12" S
S
12" S
S
12" S
S
12" S
S
12" S
S
12"
S
S
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
8" W
E
E
E
E
E
E
E
E
EV
E
E
DS
DS
DS
DS
U
D
U
D
U
D
U
D
U
D
SC
E
E
T
F
EE
G
E
N
N MAS
O
N
S
T
R
E
E
T
PLANNED
50'' FL-FL
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
8
0
.
5
0
81.34
81.48
82
.
1
2
82.10
82.18
81.58
81.
8
9
8
1
.
5
3
81.5
0
8
1
.
6
0
8
2
.
3
6
82.68
81.66
82.21
8
1
.
8
8
84.50
8
1
.
8
8
8
1
.
7
1
82.0
4
8
1
.
3
9
8
1
.
3
1
8
0
.
7
0
80.86
80.9
5
8
1
.
2
3
8
0
.
5
8
8
2
.
2
6
82.03
8
1
.
9
3
8
1
.
5
1
8
1
.
5
9
83.
8
8
83
.
8
3
84.44
83
.
8
3
8
3
.
7
4
83.53
84.16
83
.
5
8
8
3
.
4
4
83.20
8
3
.
5
4
83.74
8
2
.
4
3
84.50
81
.
1
2
7
8
.
1
7
78.00
78.00
78.00
79
.
8
8
7
9
.
0
0
79
.
0
0
79
.
0
2
79.00
83.34
81.02
0.
8
%
1.9
%
3
.
3
%
3.
5
%
2
.
3
%
2.2
%
1.9%
3.2
%
2
.
2
%
3.2
%
1.5%
1.7
%
1.5%
1.8%
1.5%
3
.
8
%
80.76
8
1
.
1
8
2.4%
9.5%
4
.
0
%
2
.
7
%
6:1
6.6%
9:1
7.6%
9:1
1.0%
2.1%
1.
5
%
8.1%
5.5
%
7.
2
%
1.2%
2.
0
%
0.6%
1
.
1
%
1
.
1
%
PLANNED 4' SIDEWALK
CHASE AND CURB CUT
SEE NOTE 6
CONCRETE RUNDOWN
AND FOREBAY 1-1
SEE DETAIL SHEET 21
4' CURB CUT
CONCRETE
EMERGENCY
SPILLWAY
6" RIBBON
CURB
EX. 6'
S
I
D
E
W
A
L
K
5' WA
L
K
8
2
.
6
3
81.82
8
2
.
2
3
81.00
81.00
81.22
8
1
.
8
9
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
(75.13)
3 - 5"/11"
RISERS
4 - 6.5"/11"
RISERS
RAILING (TYP.)
SEE LANDSCAPING PLANS
84
.
5
0
84.4
5
83.4
5
82.4
8
82.
0
2
82.58
82.32
82.4
2
82.2
4
85.00
82.4
5
82.
3
5
82.35
84.50
2.
0
%
8
2
.
1
9
8
2
.
2
9
FFE=84.50
LOT 2
STORM DRAIN LINE A
SEE SHEET ST1
STORM DRAIN LINE R3
SEE SHEET ST5
80.00
80.00
81.42
80.23
8
0
.
1
0
84.18
8
4
.
4
2
81.95
82.08
8
.
3
%
1.0%
6
.
1
%
80.85
82.98
84.4
1
7
8
.
0
0
79.00
STORM DRAIN LINE B
SEE SHEET ST3
6" RIBBON CURB
83.
7
1
82.61
84.
0
2
83
.
9
2
84.0
2
82
.
3
1
82
.
5
8
82.43
82
.
0
9
81.
6
5
81.61
0.1%
2
.
7
%
0.6%
0.7
%
0.5%
0.7%
81.31
3
.
6
%
1
.
9
%
0.7%
0.8%
0.6%
2.
0
%
2.0%
1.
7
%
5.5%
78.00
79.00
78.00
79.00
4:1
4:1
3
:
1
4:1
4:1
5:1
4:1
81.64
81.53
8
2
.
3
0
82.30
1.8%
7.
4
%
0.0%
82.
3
8
81.70
81.72
8
2
.
2
0
8
2
.
2
7
84.38
8
4
.
5
0
RAILING (TYP.)
SEE LANDSCAPING PLANS
RAILING (TYP.)
SEE LANDSCAPING PLANS 1
.
7
%
2.2
%
2
.
1
%
2.
3
%
2.1%
LOT 1
1
.
7
%
82.02
2
.
3
%
2
.
2
%
82.04
MONUMENT SIGN
(SEE ARCH. PLANS)
78.17
78.
1
7
78.17
RAIN GARDEN 1
REQ VOL. 1,405 CUFT
PROVIDED VOL. 1,870 CUFT
PROVIDED FLAT AREA = 1,442 SQFT
CONCRETE FOREBAY 1-3
SEE DETAIL SHEET 21
CONCRETE FOREBAY 1-4
SEE DETAIL SHEET 21
CONCRETE RUNDOWN
AND FOREBAY 1-2
SEE DETAIL SHEET 21
2
.
7
%
81.6
9
81.7
7
81.77
81.75
2.3%
0.2%
1.0%
78.00
78
.
0
0
78.00
78
.
0
0
1.
0
%
END CONCRETE
RETAINING WALL
N:137699.57
E:194217.94
83.
6
2
82.41
82
.
3
4
82
.
2
9
0.4%
0.4%
0
.
5
%
2
.
0
%
4
.
7
%
5
.
0
%
84
.
5
0
84
.
5
0
83
.
1
8
4
.
8
%
4
.
8
%
5
.
0
%
4.8%
5.0%
83.92
83.
9
3
2
.
0
%
2
.
0
%
0
.
5
%
4.8%
81.66
81.
5
6
81.84
81.
9
6
2
.
3
%
2
.
0
%
2
.
0
%
6:1
4:1
5:1
4:1
8
2
.
1
3
2.
5
%
2.
0
%
TRASH ENCLOSURE
(SEE LANDSCAPING PLANS)
TRASH ENCLOSURE
(SEE LANDSCAPING
PLANS)
82.0
3
3
.
2
%
0.5%
0.6%
6" CURB
8.
3
%
4
.
7
%
82
.
2
5
83.24
2.2
%
2.2
%
2.2%
1.
1
%
9.9%
10:1
4' WALK
w
/
6
"
RIBBON C
U
R
B
4' WALK w
/
6
"
RIBBON C
U
R
B
BIKE RACKS
(TYP.)
4
1
1
1
5
RETAINING WALL
SEE LANDSCAPING PLANS
G2
DE
T
A
I
L
E
D
G
R
A
D
I
N
G
P
L
A
N
8
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.FOREBAYS SHALL BE CONSTRUCTED ON COMPACTED SOIL AND NOT RAIN GARDEN
MEDIA. SEE DETAIL 400 SHEET 20 FOR MORE INFORMATION.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
UD
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
G3 G1
G2G4
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G1
MATCH LINE - SEE SHEETG4
DOWNSPOUT LEGEND
1
2PROVIDE CONCRETE CHANNEL FROM DOWNSPOUT TO CHASE.
PROVIDE 1/2" EXPANSION JOINT AT BUILDING FACE
3
PIPE CONNECTION TO STORM DRAIN (SEE SHEET 20)
PROVIDE PIPED DOWNSPOUT CONNECTION TO CHASE
4STORM CONNECTION TO BUILDING (SEE M/E/P PLANS)
5TYPICAL DOWNSPOUT (SEE ARCH. PLANS)
1.COORDINATE DOWNSPOUT LOCATIONS AND ELEVATION WITH ARCHITECTURE
PLANS PRIOR TO CONSTRUCTION.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SS
SS
SS
SS
SS
SS
SS
DS
DS
DS
DS
DS
DS
DS
DS
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
FFE=84.50
79.627
9
.
0
7
78.67
79.01
8
0
.
5
3
83.18
8
3
.
1
8
8
3
.
8
3
8
3
.
8
3
8
3
.
1
8
84
.
2
5
8
4
.
5
0
84.35
7:1
4:1
10:1
12.2%
2.6%
5.0%2.9%
FFE=84.50
CONCRETE RUNDOWN
AND FOREBAY 2-1
SEE DETAIL SHEET 21
4' CURB CUT
CONCRETE
EMERGENCY
SPILLWAY
30' STORMWATER & UTILITY
EASEMENT PER MASON STREET
INFRASTRUCTURE PLAT
10.6%
82
.
0
9
5.2%
DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
8
3
.
1
1
83.52
8
3
.
5
9
83.32
83.8
3
84
.
5
0
8
3
.
8
4
83
.
8
7
2.0%
83.5
8
83
.
6
5
83
.
1
2
83.
3
0
8
3
.
3
2
83.
5
2
84
.
5
0
84
.
5
0
84.2
4
2.
0
%
2.1
%
2.3
%
8
2
.
1
2
82.35
LOT 2
0.
5
%
2.0%2.0%
4:1
5:1
81.
0
0
81.00 80.00 80.00 81.00 8
1
.
0
0
8
1
.
9
1
8
1
.
7
9
8
2
.
0
0
78.16
STORM DRAIN LINE A
SEE SHEET ST1
STORM DRAIN LINE C
SEE SHEET ST3
STORM DRAIN LINE R2
SEE SHEET 1678.61
78.16
78.60
78.16
78.61
78
.
6
7
78.
1
9
78.16
78.
6
7
78.16
78.
6
5
78.17
78.
3
3
2.0
%
83.64
83.75
3
.
9
%
83.40
83.25
83.34
1.
0
%
2
.
9
%
3
.
0
%
83.
9
2
83.
9
3
83.
9
1
84.
1
3
83.
6
2
83.
4
0
83.
6
4
8
4
.
3
0
8
4
.
0
9
83.87
8
4
.
0
4
84.34
8
4
.
0
3
83.6
7
83
.
6
3
(83.92)
84.21
83.
9
6
8
3
.
6
9
8
3
.
7
9
83
.
8
5
83.90
2.
0
%
5.
8
%
83.
7
4
83.
9
4
83.87
8
3
.
7
4
83.6
6
2.
0
%
2.
0
%
STORM DRAIN LINE R1
SEE SHEET ST5
COURTYARD DRAINS
SEE SHEET ST4
RAIN GARDEN 2
REQ VOL. 682 CUFT
PROVIDED VOL. 915 CUFT
PROVIDED FLAT AREA = 1,532 SQFT
CONCRETE FOREBAY 2-2
SEE DETAIL SHEET 21
78
.
1
6
78.33
CONCRETE FOREBAY 2-3
SEE DETAIL SHEET 21
78.16
78.
3
3
1.
3
%
4.5%
8
.
8
%
7.
2
%
FENCE
(SEE LANDSCAPING PLANS)
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
PLANNED NATURAL
HABITAT BUFFER ZONE
79
.
6
2
SHADE STRUCTURE COLUMNS, TYP.
(SEE LANDSCAPING PLANS)
7.3%
11
.
9
%
1
8
.
4
%
10.1
%
1.3%
1.8%
5
.
5
%
9.
1
%
2
.
3
%
4
.
6
%
7
.
9
%
2.0%
1
1
1
1 1
1
1
8
4
.
3
5
1
G3
DE
T
A
I
L
E
D
G
R
A
D
I
N
G
P
L
A
N
9
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.FOREBAYS SHALL BE CONSTRUCTED ON COMPACTED SOIL AND NOT RAIN GARDEN
MEDIA. SEE DETAIL 400 SHEET 20 FOR MORE INFORMATION.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
UD
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
MATCH LINE - SEE SHEETG1
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G4
G3 G1
G2G4
DS
DS
UDUD
HICKORY REGIONAL
DETENTION POND
LOT 1
8
3
.
1
5
8
2
.
8
7
82.78
8
3
.
0
8
83.83
8
3
.
6
4
8
3
.
5
9
84.39
84.4
5
6
.
4
%
6
.
6
%
3.2
%
2.7%
2
.
5
%
2.7%
6.
0
%
??
?
2.
0
%
24' EMERGENCY ACCESS
EASEMENT PER MASON STREET
INFRASTRUCTURE PLAT
0.8
%
83
.
1
2
84
.
5
0
84
.
5
0
84.49
8
4
.
0
3
1.9
%
2.
3
%
FFE=84.50
LOT 2
STORM DRAIN LINE A
SEE SHEET ST1
8
4
.
0
3
8
3
.
9
7
8
4
.
2
0
8
3
.
6
5
8
3
.
7
5
8
3
.
7
8
83.6
7
83
.
6
3
(83.92)
84.24
84.22
8
4
.
4
0
84.49
84.46
8
4
.
2
7
8
4
.
4
5
84.10
84.02
83.97
83.54
8
3
.
9
9
83.87
83.58
2.0%
8
3
.
4
3
COURTYARD DRAINS
SEE SHEET ST4
2.6
%
1.0
%
2.0
%
0.7
%1.8
%
2.8
%
2.0%
2.0
%
4.4%
3.5%
83.91
8
3
.
5
1
8
3
.
0
9
83.58
8
4
.
0
7
8
3
.
3
3
8
3
.
5
5
8
3
.
6
2
83.91
2.1
%
4.5%
3.7
%
5.
9
%
1
2
.
4
%
9
.
1
%
1.9%
2.0%
1.
0
%
1.
3
%
2.2%
84.35
84.05
1.9
%
1
.
6
%
FENCE
(SEE LANDSCAPING PLANS)
PLANNED NATURAL
HABITAT BUFFER ZONE
84.41
8
3
.
6
5
5.1%
6.9%
10
.
6
%
1
2
.
2
%
2.
3
%
2.5%
1.7%
2.0%
2.8
%
1
.
4
%
84.08
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
1
1
G4
DE
T
A
I
L
E
D
G
R
A
D
I
N
G
P
L
A
N
10
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.FOREBAYS SHALL BE CONSTRUCTED ON COMPACTED SOIL AND NOT RAIN GARDEN
MEDIA. SEE DETAIL 400 SHEET 20 FOR MORE INFORMATION.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
UD
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
G3
MATCH LINE - SEE SHEETG2
G3 G1
G2G4
DOWNSPOUT LEGEND
1
2PROVIDE CONCRETE CHANNEL FROM DOWNSPOUT TO CHASE.
PROVIDE 1/2" EXPANSION JOINT AT BUILDING FACE
3
PIPE CONNECTION TO STORM DRAIN (SEE SHEET 20)
PROVIDE PIPED DOWNSPOUT CONNECTION TO CHASE
4STORM CONNECTION TO BUILDING (SEE M/E/P PLANS)
5TYPICAL DOWNSPOUT (SEE ARCH. PLANS)
1.COORDINATE DOWNSPOUT LOCATIONS AND ELEVATION WITH ARCHITECTURE
PLANS PRIOR TO CONSTRUCTION.
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
FDC
SSS
UD
S
C
TF
EM
E
G
G
GM
UDUDUD
GEN
E
E
ELEC
F
CTV
CTV CTV CTV CTV CTV
OHU OHU OHU OHU
CTV
X X X X
X X X X X X X
CTV
G G G
G G G G G G
SS SS SS SS SS SS
HY D
S
FE S
FE S
XX
X
X
X
X
W W W W W W W
W W
SSSSSS
S
S
S
S
S
S
W W
S
8" W
S
E E E E E E E E E E E E E E E E E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
I
UDUDUDUDUDUDUDUDUDUDUDUDUD
UD
UD
UD
U
D
UD
UD
U
D
U
D
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
12
"
S
S
12
"
S
S
12
"
S
S
12
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
12" SS
1
2
"
S
S
12" SS
1
2
"
S
S
1
2
"
S
S
8
"
W
8
"
W
8
"
W
8" W
8" W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8"
W
8"
W
8"
W
8"
W
8"
W
12" SS 12" SS
EEEEEEE
E
E
E
T
F
SC
E
V
W
F
N
M
A
S
O
N
S
T
R
E
E
T
WANKIER LANCE
1401 N. COLLEGE AVENUE
FORT COLLINS, CO
WOOD RONALD G/ JENNIFER
L/ WILLARD E
122 HIBDON COURT
FORT COLLINS, CO
THOMPSON PROPERTIES LLC
1319 N. COLLEGE AVENUE
FORT COLLINS, CO
EXISTING FIRE
HYDRANT
PLANNED NATURAL
HABITAT BUFFER ZONE
SEE NOTE 6
45' ROW
BK 1743 PG 632
LOT LINE
HICKORY REGIONAL
DETENTION POND
LOT 1
LOT 2
LOT 3
PLANNED
71' ROW
PLANNED
42'' FL-FL
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
PLANNED 3/4"
IRRIGATION
METER PIT
PLANNED 2" WATER METER VAULT
(SEE NOTE 6)
WATER METER TO BE INSTALLED
PLANNED 3 PHASE
ELECTRIC BOX
(CITY OF FORT COLLINS)
SEE NOTE 6
PLANNED 6" PVC
FIRE SERVICE
SEE NOTE 6
PLANNED 15"
HDPE STORM
SEE NOTE 6
PLANNED 6" PVC
SANITARY SERVICE
SEE NOTE 6
HIBDON COURT
PLANNED 4' SIDEWALK
CHASE AND CURB CUT
SEE NOTE 6
PLANNED
50'' FL-FL
20' EMERGENCY ACCESS
EASEMENT PER MASON
STREET INFRASTRUCTURE
PLAT
RAIN GARDEN 2
RAIN
GARDEN 1
TRASH
ENCLOSURE
TRANSFORMER AND
SWITCH CABINET
PLANNED 3 PHASE
ELECTRIC BOX
(CITY OF FORT COLLINS)
SEE NOTE 6
GAS METER
CONNECTION TO BE
COORDINATED WITH
UTILITY PROVIDER
10' UTILITY EASEMENT PER
MASON STREET
INFRASTRUCTURE PLAT
AREA INLET
(TYP.)
AREA INLET
(TYP.)
UNDERDRAIN FOR
ARTIFICIAL TURF
PLANNED GAS LINE
SEE NOTE 6
PLANNED ELECTRIC LINE
SEE NOTE 6
9
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
9
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
STORM DRAIN A
SEE SHEET 12
24' EMERGENCY ACCESS
EASEMENT PER MASON STREET
INFRASTRUCTURE PLAT
PROPOSED SANITARY
SEWER SERVICE SEE
DETAIL THIS SHEET
DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
GENERATOR
MONUMENT SIGN
(SEE ARCH. PLANS)
STORM DRAIN B
SEE SHEET 14
STORM DRAIN R3
SEE SHEET 16
PLANNED STREET LIGHT
AND TRANSFORMER
(CITY OF FORT COLLINS)
SEE NOTE 6
30' STORMWATER &
UTILITY EASEMENT PER
MASON STREET
INFRASTRUCTURE PLAT
STORM DRAIN A
SEE SHEET 13
STORM DRAIN A7
SEE SHEET 13
COURTYARD DRAINS
SEE SHEET 15
UNDERDRAIN FOR
ARTIFICIAL TURF
STORM DRAIN R2
SEE SHEET 16
STORM DRAIN R1
SEE SHEET 16
PLANNED CONNECTION VAULT
(CITY OF FORT COLLINS)
SEE NOTE 6
STORM DRAIN C
SEE SHEET 14
PLANNED SANITARY SERVICE
SEE NOTE 6
PLANNED 24" HDPE STORM
SEE NOTE 6
PLANNED FIRE
HYDRANT
SEE NOTE 6
DS
DS
DS
SSS
S
C
TF
EM
E
E
G
G
G
G
GEN
E
E
E
S
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
E
V
45° WYE A3-3 w/ CLEANOUT
INV. IN=4973.28 (W)
INV. OUT=4973.28 (NE)
FG=4981.31
N: 137568.91
E: 194209.98
45° WYE A3-4 w/ CLEANOUT
INV. IN=4973.77 (NW)
INV. OUT=4973.77 (E)
FG=4981.21
N: 137571.10
E: 194185.26
45° WYE A3-5 w/ CLEANOUT
INV. IN=4974.46 (N)
INV. OUT=4974.46 (SE)
FG=4981.36
N: 137597.29
E: 194163.33
GI CONNECTION A3-6.2
INV. IN=4975.27 (N)
INV. OUT=4975.27 (S)
FG=4976.22
N: 137632.91
E: 194175.94
GI CONNECTION A3-6.3
INV. IN=4975.27 (N)
INV. OUT=4975.27 (S)
FG=4976.22
N: 137643.86
E: 194176.94
45° WYE A3-6.1
INV. IN=4975.11 (N)
INV. OUT=4975.11 (SW)
FG=4975.65
N: 137624.94
E: 194175.22
45° WYE A3-6
INV. IN=4974.84 (N)
INV. IN=4974.84 (NE)
INV. OUT=4974.84 (S)
FG=4975.43
N: 137616.42
E: 194165.01
SS STUB A3-7
INV. OUT=4975.86 (S)
FG=4976.41
N: 137667.47
E: 194169.46
SS STUB A3-6.4
INV. OUT=4975.73 (S)
FG=4976.27
N: 137666.64
E: 194178.93
SS STUB A4-1
INV. IN=4972.75 (SW)
INV. OUT=4972.75 (NE)
FG=4973.29
N: 137590.56
E: 194257.57
24.82 LF 6" PVC @ 2.00%
34.16 LF 6" PVC @ 2.00%
19.21 LF 6" PVC @ 2.00%
51.24 LF 6" PVC @ 2.00%
13.29 LF 6" PVC @ 2.00%
8.00 LF 6" PVC @ 2.00%
22.86 LF 4" PVC @ 2.00%
52.28
L
F
6
"
P
V
C
@
1
.
0
0
%
PLANNED 6" PVC
SANITARY SERVICE
SEE NOTE 6
N
M
A
S
O
N
S
T
R
E
E
T
GREASE INTERCEPTOR
SEE DETAIL SHEET 17
STORM DRAIN LINE R3
SEE SHEET 16
5' FL - SEWER
9.5'
U1
UT
I
L
I
T
Y
P
L
A
N
11
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARDS,
LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARDS
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
5.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
6.ALL IMPROVEMENTS LABELED "PLANNED" ARE PART OF THE MASON STREET
INFRASTRUCTURE PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE
FOUND IN THE MASON STREET INFRASTRUCTURE UTILITY PLANS.
7.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
8.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY GRADING,
CONSTRUCTION OR MAINTENANCE ACTIVITIES EXCEPT AS APPROVED BY THE CITY
ENVIRONMENTAL PLANNER.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
G
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
PROPOSED GENERATOR
PROPOSED CONNECTION VAULT
PROPOSED TRANSFORMER
EV
T
PROPOSED SWITCH CABINET SC
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
S
SS
UD
UD
SC
TF
EM
E
E
G
G
G
G
GE
N
U
D
E
E
E
S
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
I
UD
UD
12" SS
8" W
8" W
8" W
8"
W
8"
W
8"
W
EV
FES A1
STA 10+00.02
N: 137491.82
E: 194219.80
110.0
3
L
F
1
8
"
H
D
P
E
@
0
.
3
5
%
BASIN A2
STA 11+10.05
N: 137523.83
E: 194114.53
95.87 L
F
1
8
"
H
D
P
E
@
0
.
5
0
%
18X12 TEE A3
STA 12+05.92
N: 137604.90
E: 194063.36
39.18 L
F
1
8
"
H
D
P
E
@
0
.
5
0
%
44.15 L
F
1
8
"
H
D
P
E
@
0
.
5
0
%
18X8 TEE A4
STA 12+45.10
N: 137638.03
E: 194042.45
35.80 LF
18" HDPE
@ 0.50%
BASIN A6
STA 13+04.99
N: 137688.68
E: 194010.48
LOT 2
60' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
RAIN
GARDEN 1
24' EMERGENCY ACCESS
EASEMENT PER MASON STREET
INFRASTRUCTURE PLAT
SANITARY SEWER
SEE SHEET 11
18X8 TEE A5
STA 12+89.25
N: 137675.37
E: 194018.88
15.74 LF 18" HDPE @ 0.50%
STORM DRAIN A7
SEE SHEET 12
COURTYARD DRAIN PLAN
SEE SHEET ST518X12 TEE A7
STA 13+40.79
N: 137723.90
E: 194004.06
4970
4975
4980
4985
4990
4995
5000
4970
4975
4980
4985
4990
4995
5000
9+7510+0011+0012+0013+0013+75
BA
S
I
N
A
6
ST
A
1
3
+
0
4
.
9
9
RI
M
4
9
8
3
.
1
±
IN
V
.
I
N
4
9
7
9
.
5
2
(
N
)
IN
V
.
O
U
T
4
9
7
9
.
5
2
(
S
E
)
18
X
8
T
E
E
A
4
ST
A
1
2
+
4
5
.
1
0
IN
V
.
4
9
7
9
.
2
3
(
N
W
)
IN
V
.
4
9
7
9
.
2
3
(
N
E
)
IN
V
.
4
9
7
9
.
2
3
(
S
E
)
18
X
1
2
T
E
E
A
3
ST
A
1
2
+
0
5
.
9
2
IN
V
.
4
9
7
9
.
0
3
(
N
W
)
IN
V
.
4
9
7
9
.
0
3
(
N
E
)
IN
V
.
4
9
7
9
.
0
3
(
S
E
)
BA
S
I
N
A
2
ST
A
1
1
+
1
0
.
0
5
RI
M
4
9
8
2
.
5
±
IN
V
.
I
N
4
9
7
8
.
5
5
(
N
W
)
IN
V
.
O
U
T
4
9
7
8
.
5
5
(
E
)
FE
S
A
1
ST
A
1
0
+
0
0
.
0
2
IN
V
.
4
9
7
8
.
1
7
(
W
)
110.03 LF 18" HDPE @ 0.35%
95.87 LF 18" HDPE @ 0.50%
39.18 LF 18" HDPE @ 0.50%44.15 LF 18" HDPE @ 0.50%35.80 LF 18" HDPE @ 0.50%
EXISTING GROUND
@ PIPE CENTERLINE
PROPOSED GROUND
@ PIPE CENTERLINE
15.74 LF 18" HDPE @ 0.50%
18
X
1
2
T
E
E
A
7
ST
A
1
3
+
4
0
.
7
9
IN
V
.
4
9
7
9
.
7
0
(
N
)
IN
V
.
4
9
7
9
.
7
0
(
E
)
IN
V
.
4
9
7
9
.
7
0
(
S
)
100-YR HGL
18
X
8
T
E
E
A
5
ST
A
1
2
+
8
9
.
2
5
IN
V
.
4
9
7
9
.
4
5
(
N
W
)
IN
V
.
4
9
7
9
.
4
5
(
N
E
)
IN
V
.
4
9
7
9
.
4
5
(
S
E
)
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT
FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
PROPOSED RIGHT OF WAY
INLET SCHEDULE:
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per Detail
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
NORTH
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
ST1
PL
A
N
&
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
A
12
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PROFILE SCALE:
STORM DRAIN A
12
ST
A
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
13
+
7
5
ST
2
LIN
EMA
T
C
H
ST
A
13
+
7
5
PRIVATELY OWNED AND MAINTAINED
DS
DS
DS
DS
DS
UD
50.23 LF 18" HDPE @ 0.50%
BASIN A8
STA 13+91.02
N: 137773.32
E: 193995.05
21.50 LF 18" HDPE @ 0.50%
INLET A9
STA 14+12.52
N: 137788.97
E: 194009.78
31.
8
9
L
F
1
5
"
H
D
P
E
@
0
.
5
0
%
8.37 LF 15" HDPE @ 0.50%
15X8 TEE A10
STA 14+44.41
N: 137788.83
E: 194041.68
15X8 TEE A11
STA 14+52.79
N: 137788.80
E: 194050.05
14.02 LF 15" HDPE @ 0.50%
15X4 TEE A12
STA 14+66.80
N: 137788.74
E: 194064.07
5.56 LF 15" HDPE @ 0.50%
INLET A14
STA 14+80.19
N: 137788.68
E: 194077.45
29.50 LF 8" HDPE @ 5.00%
RD A15
STA 15+09.69
N: 137812.39
E: 194095.00
COURTYARD DRAINS
SEE SHEET 15
15X8 TEE A13
STA 14+72.36
N: 137788.71
E: 194069.62
7.83 LF 15" HDPE @ 0.50%
4970
4975
4980
4985
4990
4995
5000
4970
4975
4980
4985
4990
4995
5000
13+7514+0015+0015+50
50.23 LF
18" HDPE
@ 0.50%
21.50 LF
18" HDPE
@ 0.50%
IN
L
E
T
A
9
ST
A
1
4
+
1
2
.
5
2
FL
.
E
L
4
9
8
3
.
1
±
IN
V
.
I
N
4
9
8
0
.
0
7
(
E
)
IN
V
.
O
U
T
4
9
8
0
.
0
7
(
S
W
)
31.89 LF
15" HDPE
@ 0.50%
15
X
8
T
E
E
A
1
1
ST
A
1
4
+
5
2
.
7
9
IN
V
.
4
9
8
0
.
2
7
(
S
)
IN
V
.
4
9
8
0
.
2
7
(
E
)
IN
V
.
4
9
8
0
.
2
7
(
W
)
8.37 LF
15" HDPE
@ 0.50%
15
X
8
T
E
E
A
1
0
ST
A
1
4
+
4
4
.
4
1
IN
V
.
4
9
8
0
.
2
3
(
E
)
IN
V
.
4
9
8
0
.
2
3
(
S
)
IN
V
.
4
9
8
0
.
2
3
(
W
)
5.56 LF 15" HDPE @ 0.50%
14.02 LF 15" HDPE @ 0.50%
15
X
4
T
E
E
A
1
2
ST
A
1
4
+
6
6
.
8
0
IN
V
.
4
9
8
0
.
3
4
(
E
)
IN
V
.
4
9
8
0
.
3
4
(
N
)
IN
V
.
4
9
8
0
.
3
4
(
W
)
IN
L
E
T
A
1
4
ST
A
1
4
+
8
0
.
1
9
FL
.
E
L
4
9
8
3
.
3
±
IN
V
.
I
N
4
9
8
0
.
4
1
(
N
E
)
IN
V
.
O
U
T
4
9
8
0
.
4
1
(
W
)
29.50 LF 8" HDPE @ 5.00%
RD
A
1
5
ST
A
1
5
+
0
9
.
6
9
RI
M
4
9
8
2
.
5
±
IN
V
.
O
U
T
4
9
8
1
.
8
8
(
S
W
)
BA
S
I
N
A
8
ST
A
1
3
+
9
1
.
0
2
RI
M
4
9
8
3
.
3
±
IN
V
.
I
N
4
9
7
9
.
9
6
(
N
E
)
IN
V
.
O
U
T
4
9
7
9
.
9
6
(
S
)
EXISTING GROUND
@ PIPE CENTERLINE
PROPOSED GROUND
@ PIPE CENTERLINE 100-YR HGL
15
X
8
T
E
E
A
1
3
ST
A
1
4
+
7
2
.
3
6
IN
V
.
4
9
8
0
.
3
7
(
E
)
IN
V
.
4
9
8
0
.
3
7
(
N
)
IN
V
.
4
9
8
0
.
3
7
(
W
)
4970
4975
4980
4985
4990
4995
5000
4970
4975
4980
4985
4990
4995
5000
9+50 10+00 11+00
18
X
1
2
T
E
E
A
7
ST
A
9
+
9
7
.
5
8
RI
M
4
9
8
1
.
2
±
IN
V
.
I
N
4
9
7
9
.
7
0
(
N
)
IN
V
.
I
N
4
9
7
9
.
7
0
(
E
)
IN
V
.
O
U
T
4
9
7
9
.
7
0
(
S
)
13.03 LF 12" HDPE @ 1.63%
12
X
8
T
E
E
A
7
-
1
ST
A
1
0
+
1
0
.
6
1
RI
M
4
9
8
1
.
0
±
IN
V
.
I
N
4
9
7
9
.
9
1
(
S
)
IN
V
.
I
N
4
9
7
9
.
9
1
(
E
)
IN
V
.
O
U
T
4
9
7
9
.
9
1
(
W
)
4.07 LF 12" HDPE @ 2.00%
12
X
8
T
E
E
A
7
-
2
ST
A
1
0
+
1
4
.
6
8
RI
M
4
9
8
1
.
2
±
IN
V
.
I
N
4
9
7
9
.
9
9
(
N
)
IN
V
.
I
N
4
9
7
9
.
9
9
(
E
)
IN
V
.
O
U
T
4
9
7
9
.
9
9
(
W
)
7.42 LF 12" HDPE @ 2.00%
IN
L
E
T
A
7
-
3
ST
A
1
0
+
2
2
.
1
0
FL
.
E
L
4
9
8
3
.
3
±
IN
V
.
I
N
4
9
8
0
.
1
4
(
E
)
IN
V
.
O
U
T
4
9
8
0
.
1
4
(
W
)
10.89 LF 8" HDPE @ 2.00%
8X
8
T
E
E
A
7
-
4
ST
A
1
0
+
3
2
.
9
9
RI
M
4
9
8
1
.
5
±
IN
V
.
I
N
4
9
8
0
.
3
6
(
N
)
IN
V
.
I
N
4
9
8
0
.
3
6
(
E
)
IN
V
.
O
U
T
4
9
8
0
.
3
6
(
W
)
RD
A
7
-
6
ST
A
1
0
+
3
8
.
9
3
RI
M
4
9
8
1
.
2
±
IN
V
.
O
U
T
4
9
8
0
.
4
8
(
W
)
3.00 LF 8" HDPE @ 2.00%
EXISTING GROUND
@ PIPE CENTERLINE
PROPOSED GROUND
@ PIPE CENTERLINE
100-YR HGL
8X
8
T
E
E
A
7
-
5
ST
A
1
0
+
3
5
.
9
9
RI
M
4
9
8
1
.
2
±
IN
V
.
I
N
4
9
8
0
.
4
2
(
E
)
IN
V
.
I
N
4
9
8
0
.
4
2
(
S
)
IN
V
.
O
U
T
4
9
8
0
.
4
2
(
W
)
2.94 LF 8" HDPE @ 2.00%
DS
DS
DS
DS
DS
DS
UD
18X12 TEE A7
STA 9+97.58
N: 137723.90
E: 194004.06
13.03 LF 12" HDPE @ 1.63%
4.07 LF 12" HDPE @ 2.00%
12X8 TEE A7-1
STA 10+10.61
N: 137726.23
E: 194016.88
12X8 TEE A7-2
STA 10+14.68
N: 137726.96
E: 194020.88
7.42 LF 12" HDPE @ 2.00%
INLET A7-3
STA 10+22.10
N: 137728.30
E: 194028.18
10.89 LF 8" HDPE @ 2.00%
8X8 TEE A7-4
STA 10+32.99
N: 137728.12
E: 194039.06
3.00 LF 8" HDPE @ 2.00%
8X8 TEE A7-5
STA 10+35.99
N: 137728.07
E: 194042.06
2.94 LF 8" HDPE @ 2.00%
RD A7-6
STA 10+38.93
N: 137728.04
E: 194045.00
COURTYARD DRAINS
SEE SHEET 15
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT
FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
PROPOSED RIGHT OF WAY
INLET SCHEDULE:
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per Detail
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
NORTH
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
ST2
PL
A
N
&
P
R
O
F
I
L
E
ST
O
R
M
A
&
A
7
13
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PROFILE SCALE:
STORM DRAIN A
PROFILE SCALE:
STORM DRAIN A7
13
NORTH
LIN
EMA
T
C
H
ST
A
13
+
7
5
ST
A
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
13
+
7
5
ST
1
PRIVATELY OWNED AND MAINTAINEDPRIVATELY OWNED AND MAINTAINED
UD
UD
G
G G
I
UD
UD
UD
UD
UD
42.25 LF 24" H
D
P
E
@
1
.
1
8
%
FES B1
STA 10+00.00
N: 137474.62
E: 194296.1760' DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
PLANNED 3/4"
IRRIGATION
METER PIT
RAIN
GARDEN 1
INLET B2
STA 10+42.25
N: 137507.46
E: 194269.58
STORM DRAIN A
SEE SHEET 12
STORM DRAIN R3
SEE SHEET 16
LOT 2
LOT 1
HICKORY REGIONAL
DETENTION POND
LOT LINE
FORBAY 1-2
SEE DETAIL SHEET 21
FORBAY 1-3
SEE DETAIL SHEET 21
FORBAY 1-1
SEE DETAIL SHEET 21
FORBAY 1-4
SEE DETAIL SHEET 21
STCO B4
STA 10+92.91
N: 137491.16
E: 194230.75
40.97 LF 4" SLOTTED HDPE @ 0.20%
9.70 LF 4" HDPE @ 0.20%
4X4 TEE B3
STA 10+51.94
N: 137515.29
E: 194263.86
16.51 LF 4" SLOTTED HDPE @ 0.20%
STCO B3-1
INV. OUT=4975.77 (SW)
FG=4978.00
4965
4970
4975
4980
4985
4990
4995
4965
4970
4975
4980
4985
4990
4995
9+5010+0011+0011+50
42.25 LF 24" HDPE @ 1.18%
FE
S
B
1
ST
A
1
0
+
0
0
.
0
0
IN
V
.
4
9
7
5
.
2
2
(
N
W
)
EXISTING GROUND @
PIPE CENTERLINE
PROPOSED GROUND @
PIPE CENTERLINE
IN
L
E
T
B
2
ST
A
1
0
+
4
2
.
2
5
RI
M
4
9
7
9
.
0
±
IN
V
.
I
N
4
9
7
5
.
7
2
(
N
W
)
IN
V
.
O
U
T
4
9
7
5
.
7
2
(
S
E
)
100-YR HGL
ST
C
O
B
4
ST
A
1
0
+
9
2
.
9
1
RI
M
4
9
7
8
.
0
±
IN
V
.
O
U
T
4
9
7
5
.
8
2
(
N
E
)
40.97 LF 4" SLOTTED HDPE @ 0.20%
4X
4
T
E
E
B
3
ST
A
1
0
+
5
1
.
9
4
IN
V
.
4
9
7
5
.
7
4
(
N
E
)
IN
V
.
4
9
7
5
.
7
4
(
S
W
)
IN
V
.
4
9
7
5
.
7
4
(
S
E
)
9.70 LF 4" HDPE @ 0.20%
4965
4970
4975
4980
4985
4990
4995
4965
4970
4975
4980
4985
4990
4995
9+75 10+00 11+00 12+00 12+25
ST
C
O
C
6
ST
A
1
1
+
9
7
.
9
9
RI
M
4
9
7
8
.
2
±
IN
V
.
O
U
T
4
9
7
6
.
0
0
(
W
)
ST
C
O
C
5
w
/
9
0
°
B
E
N
D
ST
A
1
1
+
0
8
.
2
4
RI
M
4
9
7
8
.
2
±
IN
V
.
I
N
4
9
7
5
.
8
2
(
E
)
IN
V
.
O
U
T
4
9
7
5
.
8
2
(
N
)
IN
L
E
T
C
3
ST
A
1
1
+
0
0
.
2
6
IN
V
.
4
9
7
6
.
8
6
(
S
)
IN
V
.
4
9
7
6
.
8
6
(
N
)
FE
S
C
1
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
7
8
.
5
±
IN
V
.
I
N
4
9
7
6
.
3
6
(
E
)
5.98 LF 4" HDPE @ -0.20%
89.75 LF 4" SLOTTED HDPE @ 0.20%
24.90 LF 24" HDPE @ 0.50%
BA
S
I
N
C
2
ST
A
1
0
+
7
5
.
3
6
RI
M
4
9
8
1
.
6
±
IN
V
.
I
N
4
9
7
6
.
7
4
(
S
)
IN
V
.
O
U
T
4
9
7
6
.
7
4
(
W
)
UP
T
U
R
N
E
D
E
L
B
O
W
C
4
ST
A
1
1
+
0
2
.
2
6
IN
V
.
4
9
7
5
.
8
3
(
S
)
IN
V
.
4
9
7
6
.
8
7
(
N
)
2.00 LF 4" HDPE @ 0.50%
EXISTING GROUND @
PIPE CENTERLINE
PROPOSED GROUND @
PIPE CENTERLINE
100-YR HGL
75.36 LF 24" HDPE @ 0.50%
UDUDUDUD
DS
DS
X X X X X X
X X X
SS
S
S
S
S
UD
FES C1
STA 10+00.00
N: 137958.43
E: 193915.22
STCO C5 w/90° BEND
STA 11+08.24
N: 137924.72
E: 193990.58
5.98 LF 4" HDPE @ -0.20%
89.75 LF 4" SLOTTED HDPE @ 0.20%
STCO C6
STA 11+97.99
N: 137924.43
E: 194080.33
WANKIER LANCE
1401 N. COLLEGE AVENUE
FORT COLLINS, CO
RAIN GARDEN 2
DRAINAGE EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
24.90 LF 24" HDPE @ 0.50%
BASIN C2
STA 10+75.36
N: 137957.60
E: 193990.58
LOT 1
HICKORY REGIONAL
DETENTION POND
LOT 2
LOT LINE
FORBAY 2-1
SEE DETAIL SHEET 21
FORBAY 2-3
SEE DETAIL SHEET 21
FORBAY 2-2
SEE DETAIL SHEET 21
EX. 75.36 LF 24" HDPE @ 0.50%
STORM DRAIN R1
SEE SHEET 16
STORM DRAIN R2
SEE SHEET 16
30' STORMWATER &
UTILITY EASEMENT PER
MASON STREET
INFRASTRUCTURE PLAT
INLET C3
STA 11+00.26
N: 137932.70
E: 193990.58
PLANNED 24" HDPE STORM
PER MASON STREET
INFRASTRUCTURE PROJECT
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
NORTH
( IN FEET )
0
1 INCH = 20 FEET
20 20 40 60
ST3
PL
A
N
&
P
R
O
F
I
L
E
ST
O
R
M
D
R
A
I
N
B
&
C
14
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PROFILE SCALE:
STORM DRAIN B
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT
FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
PROPOSED RIGHT OF WAY
INLET SCHEDULE:
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per Detail
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
STORM DRAIN C
PROFILE SCALE:
NORTH
LEFT
RIGHT
PRIVATELY OWNED AND MAINTAINEDPRIVATELY OWNED AND MAINTAINED
DS
DS
DS
DS
DS
DS
DS
G
G
G
G
G
G
G
UD
UDUD
LOT 2
LANDSCAPING WALL
(SEE LANDSCAPING PLANS)
15X8 TEE A10
INV. IN=4980.23 (E)
INV. IN=4980.23 (S)
INV. OUT=4980.23 (W)
FG=4981.68
N:137788.83
E:194041.68
8.41 LF 8" HDPE @ 2.00%
INLET A10-1
INV. IN=4980.40 (S)
INV. OUT=4980.40 (N)
FG=4983.25
N:137780.42
E:194041.64
6.88 LF 8" HDPE @ 2.00%
INLET A10-2
INV. OUT=4980.54 (N)
FG=4983.52
N:137773.55
E:194041.6115X8 TEE A11
INV. IN=4980.27 (S)
INV. IN=4980.27 (E)
INV. OUT=4980.27 (W)
FG=4981.72
N:137788.80
E:194050.05
6.25 LF 8" HDPE @ 2.00%
RD A11-1
INV. OUT=4980.40 (N)
FG=4981.17
N:137782.54
E:194050.02
15X4 TEE A12
INV. IN=4980.34 (E)
INV. IN=4980.34 (N)
INV. OUT=4980.34 (W)
FG=4981.72
N:137788.74
E:194064.07
16.19 LF 4" SLOTTED HDPE @ 0.20%
CO A12-1
INV. OUT=4980.37 (S)
FG=4984.08
N:137804.93
E:194064.14
INLET A7-4.1
INV. OUT=4980.46 (S)
FG=4983.52
N:137733.32
E:194039.15
5.20 LF 8" HDPE @ 2.00%
8X8 TEE A7-4
INV. IN=4980.36 (N)
INV. IN=4980.36 (E)
INV. OUT=4980.36 (W)
FG=4981.53
N:137728.12
E:194039.06
INLET A7-2.1
INV. OUT=4980.19 (S)
FG=4983.30
N:137736.71
E:194019.10
9.91 LF 8" HDPE @ 2.00%
12X8 TEE A7-2
INV. IN=4979.99 (N)
INV. IN=4979.99 (E)
INV. OUT=4979.99 (W)
FG=4981.16
N:137726.96
E:194020.88
12X8 TEE A7-1
INV. IN=4979.91 (S)
INV. IN=4979.91 (E)
INV. OUT=4979.91 (W)
FG=4981.02
N:137726.23
E:194016.88
8.29 LF 8" HDPE @ 2.00%
INLET A7-1.1
INV. OUT=4980.08 (N)
FG=4983.12
N:137718.08
E:194018.36
3
4
.
0
6
L
F
8
"
H
D
P
E
@
2
.
0
0
%
RD A5-1
INV. OUT=4980.13 (SW)
FG=4984.05
N:137693.55
E:194047.69
18X8 TEE A5
INV. IN=4979.45 (NW)
INV. IN=4979.45 (NE)
INV. OUT=4979.45 (SE)
FG=4981.20
N:137675.37
E:194018.88
18X8 TEE A4
INV. IN=4979.23 (NW)
INV. IN=4979.23 (NE)
INV. OUT=4979.23 (SE)
FG=4980.98
N:137638.03
E:194042.45
4
1
.
3
4
L
F
8
"
H
D
P
E
@
2
.
0
0
%
RD A4-1
INV. OUT=4980.06 (SW)
FG=4984.22
N:137660.10
E:194077.40
18X12 TEE A3
INV. IN=4979.03 (NW)
INV. IN=4979.03 (NE)
INV. OUT=4979.03 (SE)
FG=4980.79
N:137604.90
E:194063.36
2
9
.
1
6
L
F
1
2
"
H
D
P
E
@
2
.
0
0
%
INLET A3-1
INV. IN=4979.61 (NE)
INV. OUT=4979.61 (SW)
FG=4983.09
N:137620.47
E:194088.02
5
6
.
9
1
L
F
1
2
"
H
D
P
E
@
2
.
0
0
%
INLET A3-2
INV. IN=4980.75 (E)
INV. IN=4980.75 (N)
INV. OUT=4980.75 (SW)
FG=4983.45
N:137652.29
E:194135.21
8.96 LF 8" HDPE @ 2.00%
RD A3-3
INV. OUT=4980.93 (W)
FG=4983.77
N:137654.28
E:194143.94
FFE=84.50
8X8 TEE A7-5
INV. IN=4980.42 (E)
INV. IN=4980.42 (S)
INV. OUT=4980.42 (W)
FG=4981.19
N:137728.07
E:194042.06
24.41 LF 4" SLOTTED HDPE @ 0.20%
CO A7-5.1
INV. OUT=4980.47 (N)
FG=4983.81
N:137703.67
E:194041.67
STORM DRAIN A
SEE SHEET 12
STORM DRAIN A7
SEE SHEET 13
STORM DRAIN A
SEE SHEET 13
6' CONCRETE WALK
6' CO
N
C
R
E
T
E
W
A
L
K
6'
C
O
N
C
R
E
T
E
W
A
L
K
10.78 LF 3" HDPE @ 2.00%
BLDG CONNECTION A3-2.1
INV. OUT=4980.97 (S)
15X8 TEE A13
INV. IN=4980.37 (E)
INV. IN=4980.37 (N)
INV. OUT=4980.37 (W)
FG=4981.82
N:137788.71
E:194069.62
10.56 LF 8" HDPE @ 2.00%
RD A13-1
INV. OUT=4980.58 (S)
FG=4984.01
N:137799.27
E:194069.67
ST4
CO
U
R
T
Y
A
R
D
D
R
A
I
N
P
L
A
N
15
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT
FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
PROPOSED RIGHT OF WAY
INLET SCHEDULE:
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per Detail
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
DS DS
DS
DS
UDUDUDUDUD
HEADWALL R2-1
INV. IN=4978.33 (SE)
FG=4978.77
N:137913.25
E:194086.15
2
7
.
2
7
L
F
8
"
H
D
P
E
@
0
.
5
0
%
45° WYE R2-2 w/ CO
INV. IN=4978.47 (SE)
INV. IN=4978.47 (S)
INV. OUT=4978.47 (NW)
FG=4979.07
N:137890.35
E:194100.95
20
.
8
1
L
F
8"
H
D
P
E
@
2
.
0
0
%
1
5
.
9
6
L
F
8
"
H
D
P
E
@
0
.
5
0
%
45° WYE R2-3 w/ CO
INV. IN=4978.55 (SE)
INV. IN=4978.55 (S)
INV. OUT=4978.55 (NW)
FG=4979.15
N:137876.95
E:194109.61
20
.
3
9
L
F
8"
H
D
P
E
@
2
.
0
0
%
8
.
2
6
L
F
8
"
H
D
P
E
@
0
.
5
0
%
RD R2-3
INV. OUT=4978.59 (NW)
FG=4983.12
N:137870.01
E:194114.09
RD R2-3.1
INV. OUT=4978.95 (N)
FG=4983.81
N:137857.01
E:194105.32
RD R2-2.1
INV. OUT=4978.88 (N)
FG=4983.12
N:137870.01
E:194096.57
HEADWALL R1-1
INV. IN=4978.33 (S)
FG=4976.20
N:137916.12
E:194050.65
21
.
7
3
L
F
8"
H
D
P
E
@
1
.
2
6
%
RD R1-2
INV. OUT=4978.60 (N)
FG=4981.37
N:137894.39
E:194050.66
RAIN GARDEN 2
DS
DS
DS
UD
UD
S
C
E
E
TF
EM
E
E
E
E
EEGEN
E
E
E
E
E
E
E
E
V
E
E
N
M
A
S
O
N
S
T
R
E
E
T
PLANNED
50'' FL-FL
TRASH ENCLOSURE
(SEE LANDSCAPE
PLANS)
E
X
.
6
'
S
I
D
E
W
A
L
K
5
'
C
R
U
S
H
E
R
F
I
N
E
W
A
L
K
10' UTILITY EASEMENT
PER MASON STREET
INFRASTRUCTURE PLAT
9
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
6' CO
N
C
R
E
T
E
W
A
L
K
1
6
3
.
7
7
L
F
8
"
H
D
P
E
@
1
.
0
0
%
HEADWALL R3-1
INV. IN=4978.17 (N)
N:137524.21
E:194255.86
90° BEND w/CO R3-3
INV. IN=4980.13 (W)
INV. OUT=4980.13 (S)
FG=4983.62
N:137714.99
E:194211.82
11.94 LF 8" HDPE @ 1.00%
RD R3-4
INV. OUT=4980.25 (E)
FG=4983.81
N:137712.30
E:194200.19
RAIN GARDEN 1
SANITARY SEWER
CROSSING
INV. ELEV = 4972.9
SANITARY SEWER
SEE SHEET 11
3
2
.
0
2
L
F
8
"
H
D
P
E
@
1
.
0
0
%
11.93 LF 8" HDPE @ 1.00%
TEE R3-2
INV. IN=4979.81 (N)
INV. IN=4979.81 (W)
INV. OUT=4979.81 (S)
FG=4980.59
N:137683.79
E:194219.02RD R3-2.1
INV. OUT=4979.93 (E)
FG=4983.98
N:137681.10
E:194207.40
MONUMENT SIGN
(SEE ARCH. PLANS)
ST5
ST
O
R
M
D
R
A
I
N
P
L
A
N
ST
O
R
M
D
R
A
I
N
R
1
,
R
2
,
&
R
3
16
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NORTH
( IN FEET )
1 inch = ft.
Feet01010
10
20 30
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
1 STORM DRAIN R1 & R2
2 STORM DRAIN R3
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
NOTES:
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT
FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
PROPOSED RIGHT OF WAY
INLET SCHEDULE:
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per Detail
UDPROPOSED UNDERDRAIN
PROPOSED DOWNSPOUT DS
PLAN VIEW
48" DIA.
FLOW
24
"
D
I
A
.
GENERAL NOTES:
1.LOCATION AND ALIGNMENT OF AMR POD ON PIT TOP CAN VARY.
2.SEE DETAIL 16-A FOR ADDITIONAL METER PIT INFORMATION.
3.REFER TO QUICK REFERENCE FOR STANDARD SETTING FOR 1 1/2 ' AND 2' WATER METERS (QUICK REFERENCE 16 A&B)
ARMOUR-FLEX TUBING
AND GROUT KNOCKOUT
BEFORE BACKFILLING
CURB
BOX
PRECAST CONCRETE
MANHOLE
MANHOLE RUNGS
12" O.C.
AMR POD (FORD YOKE BOX
PART #YUC-7 WITH FORD YOKE
BOX LID PART #YL-TP WITH 1
27/32" DIA. HOLE AND
REMOVABLE PLUG)
8" x 8" CONCRETE
BLOCK (TYP.)
METER (PLACED
BELOW LID)
1" DIA. IRON
PIPE BRACE
(TYP)
6"
8" LAYER OF 3/4" TO 1 1/2" GRAVEL
8"
12"
(MIN.)
CURB BOX
1-1/2" METERS
FLOW
2" METERS
17 1/4" FOR
13 1/4" FOR
48"
24"
54
"
(
M
I
N
.
)
66
"
(
M
A
X
.
)
16
"
(
M
A
X
.
)
7"
(
M
I
N
.
)
3" (MAX.)
1" (MAX.)
2' (MAX.)
3/4" ROCK FOR GRADE
ADJUSTMENT (IF REQ'D)
12"
(MIN.)
(M
A
X
.
)
CURB STOP
GENERAL NOTES:
1.SUPPORT METER SETTERS BY (2) 18 INCH LENGTHS OF 1 INCH IRON PIPE INSERTED THROUGH BRACE PIPE EYELETS AND SET ATOP (4) 8 INCH SQUARE CONCRETE BLOCKS OR APPROVED EQUAL.
2.METER PITS AND VAULTS SHALL NOT BE INSTALLED IN ANY STREET, ALLEY, PARKING AREA OR DRIVEWAY. ANY PIT OR VAULT INSTALLED IN A SIDEWALK DUE TO LIMITED OPTIONS MUST BE
PRE-APPROVED IN THE DEVELOPMENT REVIEW PROCESS AND WILL REQUIRE A TRAFFIC RATED METER PIT AND LID.
3.NO LANDSCAPING (TREES, SHRUBS, BOULDERS, ETC.) OR RETAINING WALLS TO BE WITHIN 4 FEET OF METER PIT AND NO TREES WITHIN 6 FEET.
4.THE METER PIT AND AMR POD(S) MUST REMAIN OPEN AND ACCESSIBLE FOR METER READING AND MAINTENANCE.
5.SLOPE GROUND SURROUNDING METER PIT AWAY FROM LID AT 2% GRADE OR GREATER.
6.MAKE NO PLUMBING CONNECTIONS (TEES, COUPLINGS, ETC.) IN METER PIT.
7.ALL TEES, COUPLINGS AND CONNECTION FITTINGS TO BE A MINIMUM OF 2 FEET FROM METER PIT WALL ON OUTLET SIDE.
8.GRADE ACCEPTANCE AFTER METER PIT INSTALLATION REQUIRES THAT THE OWNER ADJUST METER PIT COVER TO 1/2 INCH ABOVE LANDSCAPED FINAL GRADE.
9.IF A PRESSURE REDUCING VALVE IS REQUIRED BY PLUMBING CODE, IT SHALL BE INSTALLED INSIDE THE BUILDING, IMMEDIATELY FOLLOWING THE MAIN SHUTOFF VALVE.
10.A SEPARATE AMR POD MUST BE INSTALLED FOR EACH METER REGISTER.
11.CONCRETE FOOTERS AND RATED RING/COVER REQUIRED IN TRAFFIC RATED AREAS.
12.REFER TO QUICK REFERENCE FOR INSTALLATION OF THE STANDARD SETTING FOR 1 1/2 " AND 2" WATER METERS (QUICK REFERENCE 16 A&B)
ARMOUR-FLEX TUBING
AND GROUT KNOCKOUT
BEFORE BACKFILLING OR
APPROVED EQUAL
PRECAST CONCRETE
MANHOLE
APPROVED JOINT
SEALANT (TYP. ALL
JOINTS)
1/2" EMT OR PVC
CONDUIT THROUGH
VAULT OR PIT TOP
INTO YOKEBOX
MANHOLE RUNGS
12" O.C.
COMPRESSION
CONNECTION
(TYP.)METER
SETTER
1" DIA. IRON
PIPE BRACE
(TYP.)
PRE-CAST CONCRETE GRADE
RINGS (IF REQUIRED)
ALUMINUM MANHOLE RING AND
COVER WITH LOCK NUT
AMR POD (FORD YOKE BOX PART
#YUC-7 WITH FORD YOKE BOX LID
PART #YL-TP WITH 1 27/32" DIA.
HOLE AND REMOVABLE PLUG)
FINISHED GRADE
2% SLOPE
TOP OF AMR LID TO
BE 1/2" ABOVE
FINISHED GRADE
INSTALL LID 1/2 IN. ABOVE
FINAL LANDSCAPED GRADE
MORTAR OR
MASTIC
4" X 6" SUPPORT BRICK
BY-PASS VALVE SHALL BE
ON THE UPSTREAM SIDE
IN BETWEEN SETTER
D1
DE
T
A
I
L
S
UT
I
L
I
T
Y
17
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
LOWER LIMIT OF
TRENCH WALL
SLOPING
INITIAL LIFT *
12 IN. MIN.
PIPE O.D.
4 IN. MIN.
TRENCH WIDTH AS SPECIFIED
IN SECTION 02221
COMPACTED GRANULAR MATERIAL
CONFORMING TO CDDH #67
*
BEDDING REQUIRMENTS
WW-1
6" WALLS MIN.
1.SECONDARY COMPARTMENT HAS VOLUME EQUAL TO
APPROXIMATELY 1/3 OF THE TOTAL CAPACITY.
2.JOINT BETWEEN LID AND VAULT TO BE SEALED WITH 1 ROW
1-1/2" BUTYL MASTIC SEALANT.
3.WALLS AND BOTTOM REINFORCED THROUGHOUT WITH 2x6/10
REMESH.
4.GREASE INTERCEPTOR MEETS ASTM C 1613 06
SPECIFICATIONS.
5.COVERS TO BE REINFORCED LONGITUDINALLY WITH NO.6
REBAR ON 6" CENTERS, NO.4 REBAR ON 6" CENTERS
WIDTHWISE, AND NO.8 REBAR DIAGONALLY AROUND THE
ACCESS HOLES.
6.PIPE WITHIN INTERCEPTOR AND CLEAN OUT SHALL BE SCHED.
40 MIN.
DESIGN PROPERTIES:
CONCRETE STRENGTH: 4,000 PSI
CONCRETE WEIGHT: 150 PCF
STEEL STRENGTH: 60,000 PSI (GRADE 60)
LOAD RATING: AASHTO HS20-44 RATED TO
1"-6" MAX. BURY
WATER LINE
10"W x 5"H
BLOCKOUT IN
24"Ø CAST IRON RING
& COVER (TYPICAL, IN
LID ABOVE PLAN VIEW)
4" THICK
BAFFLE WALL
BAFFLE WALL
CLEANOUT TO GRADE
LONG SWEEP WYE,
SCHEDULE 40 MATERIAL
VENT PIPING WITH VTR
OR INTERNAL TANK VENT
VE
N
T
T
H
R
U
R
O
O
F
O
F
B
U
I
L
D
I
N
G
WATER
CAPACITY
APPROX.
GALLONS
GREASE
CAPACITY
APPROX.
CUBIC FT.
DIMENSIONS
NOTES:
A B C D E F G
750 4'7'46"48"44"62"26"
1000 6'10'31"33"29"48"38"
1250 6'10'36"38"34"54"38"
1500
2000
2500
6'13'33"35"31"54"50"
6'13'44"46"42"60"50"
6'12'58"60"56"78"48"
TRANSITION TO GASKETED
SDR-35 PIPE DOWN STREAM OF
CLEANOUT
250
333
416
500
666
833
24"Ø CAST IRON RING
& COVER (TYPICAL)
G
A
B
8"
L
I
D
D
12
"
C
2
1
/
2
"
12
"
G
F
E
(
T
Y
P
.
)
6"
H
H
10"W x 5"H
BLOCKOUT IN
BAFFLE WALL
8"x4" BLOCKOUT FOR 4"
TO 6" PIPE (TYPICAL
OPPOSITE END)
17 1/2"
10"
13"
11 1/2"
17"
24"
GREASE INTERCEPTOR
WW-10
VAULT DIMENSIONS MAY VARY FROM WHAT
IS SHOWN WITH ENGINEER'S APPROVAL.
FLOW DIRECTION
TRAFFIC RATED CLEANOUT
WW-15
PRIOR TO CONSTRUCTION CONFIRM SIZE (1,000 GAL.) WITH
MEP PLANS. CIVIL HAS COORDINATED AS OF 02/2024
APPROVED:
DRAWN BY:DETAILS
CONSTRUCTION DATE REVISED:
DETAILWATER
STANDARD SETTING FOR 1-1/2" AND 2" WATER METERS (PLAN VIEW)
5/20/2022
SAA
W-16B
APPROVED:
DRAWN BY:DETAILS
CONSTRUCTION DATE REVISED:
DETAILWATER
STANDARD SETTING FOR 1-1/2" AND 2" WATER METERS
4/20/2022
SAA
W-16A
BACK OF CURB
EDGE OF STREET
58" GALV. STEEL PLATE
21 2 1
3"x2"x38" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
6"
6"
VARIES
2'
3'
SECTION B-B
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES 0.5% SLOPE (MIN.)
VARIES VARIES
2' DEPRESSED GUTTER
VARIE
S
EXPANSION
MATERIAL
58" GALV.STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3"3'-3"
6" (TY
P
.
)
BACK
OF
CURB
3" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALK
VARI
E
S
VARI
E
S
SL
O
P
E
CC
BB
A
A
8'-6"
EXPANSION
MATERIAL
38" BRASS SCREW 18" O.C.WITH COUNTERSINK
HEAD FLUSH WITH PLATE2'
6"
3"x2"x38"
GALV. ANGLE
58" GALV.
STEEL PLATE
#3 REBAR
ANCHOR
18 O.C.
38" BRASS SCREW
18 O.C. WITH
COUNTERSUNK HEAD
FLUSH WITH PLATE
DETAIL 1
D2
DR
A
I
N
A
G
E
D
E
T
A
I
L
S
18
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
FLUSH/RIBBON CURB 18" INFLOW
18" OUTFALL
PRIVATE CURB & GUTTER203
REFER TO SHEET 5 FOR LOCATIONS OF SPECIFIC CURB TYPE.
204 CURB OPENING DETAIL
5 8" GALV. STEEL PLATE
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
SECTION B-B
SECTION A-A
PLAN
0.5% SLOPE (MIN.)
5 8" GALV. STEEL
PLATE
B B
A
3 8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE
206 COMBINED SIDEWALK CHASE
DETAIL "A"
PLAN VIEW
200 STORMWATER BEDDING DETAIL 201 STORMWATER BEDDING DETAIL 202 CONCRETE PAN DETAIL
205 SIDEWALK CHASE DETAIL
CRUSHER FINES
0.5'0.5'1'
2'
A
6" RIBBON
CURB
6" RIBBON
CURB
6" HDPE STORM
6" HDPE STORM
6' CONCRETE SIDEWALK
CRUSHER FINES
FOR SIDEWALK CHASE EXTENSION
SOUTH OF CRUSHER FINES SIDEWALK
SEE FORT COLLINS DETAIL D-10B
FOR SIDEWALK CHASE
EXTENSION SOUTH OF
CRUSHER FINES SIDEWALK
SEE FORT COLLINS DETAIL
D-10B
CONCRETE CHANNEL DETAIL207
FG
0.5'
X'
0.5'
#4@6"
O.C.
#4L@12"
O.C.
3"
CL
R
.
#4@12"
O.C.
#4L@12"
O.C.
AA
Ls
Ws
6"
6"
SECTION A-A
6"
PLAN
1
GENERAL NOTES
SECTION B-B
B
B
6"
6"
4'
4'
6"
6"
INLET C3 ELEVATIONS
D3
DR
A
I
N
A
G
E
D
E
T
A
I
L
S
19
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
302 INLET SCHEDULE
INLET SCHEDULE
Inlet/Basin ID Inlet Size Grate Type
Inlet A9 18" Nyloplast Basin 18" Dome
Inlet A14 15" Nyloplast Basin 15" Dome
Inlet A3-1 12" Nyloplast Basin 12" Dome
Inlet A3-2 12" Nyloplast Basin 12" Dome
Inlet A10-1 8" Nyloplast Basin 8" Dome
Inlet A7-3 12" Nyloplast Basin 12" Dome
Inlet A10-2 8" Nyloplast Basin 8" Dome
Inlet A7-4.1 8" Nyloplast Basin 8" Dome
Inlet A7-2.1 8" Nyloplast Basin 8" Dome
Inlet A7-1.1 8" Nyloplast Basin 8" Dome
Inlet B2 Type C Inlet Per Detail
Inlet C3 Modified Outlet Structure Per DetailREVE7001-110-298DWG NO.1 OF 1SHEET1:40SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
DRAIN BASIN WITH SOLID COVER
QUICK SPEC INSTALLATION DETAIL
TITLE
PROJECT NO./NAME
MATERIAL
DATE
REVISED BY
09-14-07DATE
EBCDRAWN BY
06-12-18
NMH
(5) ADAPTER
ANGLES
VARIABLE 0° - 360°
ACCORDING TO
PLANS
8" - 36"
8" MIN THICKNESS GUIDELINE
(3) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN. ON 8" - 24", 10" MIN. ON 30"
& 12" MIN. ON 36"
BASED ON MANUFACTURING REQ.)
4" MIN ON 8" - 24"
6" MIN ON 30" & 36"
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
(MIN. MANUFACTURING
REQ. SAME AS MIN. SUMP)
(3) VARIABLE INVERT HEIGHTS
AVAILABLE (ACCORDING TO
PLANS/TAKE OFF)
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS
AVAILABLE: 4" - 36" FOR CORRUGATED HDPE
(ADS N-12/HANCOR DUAL WALL, ADS/HANCOR
SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905,
CORRUGATED & RIBBED PVC
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
NYLOPLAST DRAIN BASIN WITH SOLID COVER
(6, 7) TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR
GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE
DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS,
TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS.
SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION.
(1, 2) INTEGRATED DUCTILE IRON
FRAME & COVER TO MATCH BASIN O.D.
THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
®
©2013 NYLOPLAST
1 - 8" - 30" SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.
2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.
8" & 10" SOLID COVERS FIT DIRECTLY ONTO DRAIN BASINS WITH THE USE OF
A PVC BODY TOP. SEE DRAWING NO. 7001-110-045.
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN
DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING
RESTRICTIONS. SEE DRAWING NO. 7001-110-065.
4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER (4" - 36").
5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.
6 - 12" - 30" SOLID COVERS SHALL MEET H-20 LOAD RATING.
7 - 8" & 10" SOLID COVERS ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY;
NO CONCRETE COLLAR NEEDED FOR LIGHT DUTY RATING.
18" MIN WIDTH GUIDELINE
300 NYLOPLAST BASIN WITH SOLID GRATE
REV E7001-110-397DWG NO.1 OF 1SHEET1:40SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
DRAIN BASIN WITH DOME GRATE
QUICK SPEC INSTALLATION DETAIL
TITLE
PROJECT NO./NAME
MATERIAL
DATE
REVISED BY
03-25-10DATE
EBCDRAWN BY
06-12-18
NMH
8" - 36"
(3) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN. ON 8" - 24", 10" MIN. ON 30"
& 12" MIN. ON 36"
BASED ON MANUFACTURING REQ.)
4" MIN ON 8" - 24"
6" MIN ON 30" & 36"
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
(MIN. MANUFACTURING
REQ. SAME AS MIN. SUMP)
(3) VARIABLE INVERT HEIGHTS
AVAILABLE (ACCORDING TO
PLANS/TAKE OFF)
THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER
GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
NYLOPLAST DRAIN BASIN WITH DOME GRATE
1 - 8" - 30" DOME GRATES SHALL BE DUCTILE IRON PER ASTM A536
GRADE 70-50-05.
2 - 8" & 10" DOME GRATES FIT ONTO THE DRAIN BASINS WITH THE USE
OF A PVC BODY TOP. SEE DRAWING NO. 7001-110-045.
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN
DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING
RESTRICTIONS. SEE DRAWING NO. 7001-110-065.
4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER (4" - 36").
5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.
6 - 8" - 30" DOME GRATES HAVE NO LOAD RATING.
(1, 2) INTEGRATED DUCTILE IRON
GRATE TO MATCH BASIN O.D.
THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
®
©2013 NYLOPLAST
(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS
AVAILABLE: 4" - 36" FOR CORRUGATED HDPE
(ADS N-12/HANCOR DUAL WALL, ADS/HANCOR
SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905,
CORRUGATED & RIBBED PVC
(5) ADAPTER ANGLES VARIABLE
0° - 360° ACCORDING TO PLANS
301 NYLOPLAST BASIN WITH DOME GRATE
I:
\
S
t
m
W
t
r
\
C
r
i
t
e
r
i
a
M
a
n
u
a
l
\
D
4
6
.
d
w
g
4/
7
/
1
1
303 MODIFIED OUTLET STRUCTURE (INLET C3)
A A
SECTION A-A
PLAN VIEW
DIRECTION OF FLOW
L
W
6.0"
DIRECTION OF FLOW
6.0" TYP.
12.0"
6.0"
6.0"
6.0"
6.0"
6.0"
CONCRETE RUN DOWN AND FOREBAY ARE PRIVATELY OWNED AND MAINTAINED
2" NOTCH
FLOWLINE OF NOTCH
FINISH GROUND
OF RAIN GARDEN
UPSTREAM CONCRETE RUNDOWN
UPSTREAM CONCRETE RUN DOWN
BIO RETENTION
SAND MEDIA
HALF INCH EXPANSION JOINT
TO BE INSTALLED BETWEEN
CONCRETE RUNDOWN & FOREBAY
PROPOSED NATIVE
MATERIAL SUBBASE
CONCRETE FOREBAY
CONCRETE FOREBAY
3.0"
2"
A A
SECTION A-A
PLAN VIEW
DIRECTION OF FLOW
PROPOSED NATIVE
MATERIAL SUBBASE
FLOWLINE OF NOTCH
FINISH GROUND
L
W
6.0"
INVERT OF PIPE (SEE STORM
DRAIN PLAN AND PROFILES)
DIRECTION OF FLOW
6.0" TYP.
2" NOTCH
3.0"
2"X6" NOTCH
12"UPSTREAM LANDSCAPING
FLUSH WITH TOP OF COLLAR
UPSTREAM LANDSCAPING
TO BE FLUSH WITH TOP OF FOREBAY
AND CONCRETE COLLAR
2"
CONCRETE COLLAR
(SEE DETAIL)
BIO RETENTION
SAND MEDIA
CONCRETE COLLAR
(SEE DETAIL)
DIRECTION OF FLOW
(4:1 MAX)
A A
SECTION A-A
PLAN VIEW
(FOR STORM SEWERS I, K, & M)
DIRECTION OF FLOW
PROPOSED NATIVE
MATERIAL SUBBASE
FLOWLINE OF NOTCH
FINISH GROUND
8'
8'
6.0"
INVERT OF PIPE (SEE STORM
DRAIN PLAN AND PROFILES)
DIRECTION OF FLOW
6.0" TYP.
2" NOTCH
3.0"
2"X6" NOTCH
12"
UPSTREAM FLARED END SECTION
FLUSH WITH BOTTOM OF FORBAY
2"
BIO RETENTION
SAND MEDIA
DIRECTION OF FLOW
(4:1 MAX)
UPSTREAM LANDSCAPING
TO BE FLUSH WITH TOP OF FOREBAY
AND TRANSITION AT A 4:1 TO TOP OF
THE FLARED END SECTION
D4
DE
T
A
I
L
S
DR
A
I
N
A
G
E
20
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
FINISHED GRADE
NYLOPLAST CLEANOUT END CAP
ADJUST GRADE TO FINISH GRADE
ELEVATION
INJECTION MOLDED
WT TEE
INSERT INJECTION MOLDED,
GASKETED SPIGOT BY
BELL REDUCER
INJECTION MOLDED
WT TEE
HDPE PIPE (TYP)
GASKETED
CONNECTION
INJECTION
MOLDED WT
90° BEND
DOWNSPOUT ADAPTER
INSERTED IN RISER
PIPE
BUILDING
FACE
COORDINATE WITH
STRUCTURAL TO AVOID
FOOTING CONFLICTS
TYPICAL ROOF LEADER CONNECTION
NOTE: CONTRACTOR TO VERIFY ALL ROOF DRAIN
AND DOWN SPOUT CONNECTIONS WITH ARCHITECT.
401
400 FOREBAY DETAILS
Forebay ID Storm Conveyance ID Depth (in)Legnth (ft)Width (ft)
Forebay 1-1
Curb Cut 2
(South Parking Lot)12 2 4
Forebay 1-2
Curb Cut 3
(N Mason Street)12 2 4
Forebay 1-3 Storm A 12 2 5
Forebay 1-4 Storm R3 12 2 2
Forebay 2-1
Curb Cut 1
(North Parking Lot)12 2 4
Forebay 2-2 Storm R1 12 2 2
Forebay 2-3 Storm R2 12 2 2
FOREBAY 1-1, 1-2, AND 2-1 FOREBAY 1-4, 2-2, AND 2-3 FOREBAY 1-3
4"
4"
R2"
4"
4"
R2"
6"
OUTLET
PIPE
FRONT VIEW SIDE VIEW
CONCRETE COLLAR402
1.CONTRACTOR SHALL INSTALL BIORETENTION BASINS ACCORDING TO THE APPROVED PLANS AND/OR CONSTRUCTION SPECIFICATIONS.
2.PRE-CONSTRUCTION
2.1.CONTRACTOR SHALL AVOID COMPACTION OF THE BIORETENTION BASIN AREA TO PRESERVE EXISTING INFILTRATION RATES.
2.2.CONTRACTOR SHALL CALL FOR CITY INSPECTIONS AT THE INTERVALS STIPULATED IN THE "DURING CONSTRUCTION INSPECTION
CHECKLISTS".
3.DURING CONSTRUCTION:
3.1.CONTRACTOR SHALL PROVIDE CONSTRUCTION OBSERVATION DURING CONSTRUCTION OF THE BIORETENTION BASIN TO ENSURE
COMPLIANCE WITH THE APPROVED PLANS AND DESIGN SPECIFICATIONS.
3.2.LOOSE MATERIALS SHALL NOT BE STORED ON THE BIORETENTION AREA.
3.3.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS AND DIRT FROM ANY
SOURCE FROM ENTERING THE BIORETENTION SYSTEM.
4.GEOTEXTILE LINERS:
4.1.WHERE USED, GEOTEXTILE LINERS (PERMEABLE OR IMPERMEABLE AS PER PLAN) SHALL BE INSTALLED ALONG PERIMETER OF
CROSS-SECTION OF THE BIORETENTION CELL.
4.2.WHERE USED, GEOTEXTILE LINERS SHALL BE PLACED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDATIONS. ALL
SEAMS AND OPENINGS IN THE LINER SHALL BE SEALED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS.
4.3.WHERE USED, IMPERMEABLE GEOMEMBRANE SHEET / LINER SHALL BE 40 MIL THICK, HIGH-DENSITY POLYETHYLENE DESIGNED
SPECIFICALLY FOR FLEXIBLE GEOMEMBRANE APPLICATIONS. ADJACENT STRIPS OF IMPERMEABLE LINER SHALL OVERLAP A MINIMUM OF 18",
OR PER MANUFACTURER'S SPECIFICATION.
4.4.WHERE USED, CONTRACTOR TO PLACE LINER IN A WAY THAT ENSURES ENOUGH SLACK IN THE LINER TO ALLOW FOR BACKFILL AND
SETTLING WITHOUT TEARING THE LINER.
5.AGGREGATES AND BSM:
5.1.ALL AGGREGATES SHALL BE ANGULAR, CRUSHED, WASHED ROCK, CLEAN OF DEBRIS AND WITH NO MORE THAN 1% FINES.
5.2.RESERVOIR AGGREGATE SHALL BE GRADATION ASTM #57 OR #67.
5.3.DIAPHRAGM AGGREGATE SHALL BE "PEA GRAVEL", WITH GRADATION ASTM #8, #89 OR #9.
5.4.THE BIORETENTION SOIL SHALL MEET THE CITY BIORETENTION SAND MEDIA ("BSM") SPECIFICATION FOUND
AT:https://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulations/
NOTES:
12
"
M
A
X
1
MAXIMUM ALLOWABLE
PONDING DEPTH IS 12" FROM
THE TOP OF THE MULCH
4 MAX
PONDING DEPTH MUST NOT
EXCEED FLOWLINE ELEVATION
OF ADJACENT GUTTER
8" MIN DEPTH THICKENED CURB
ADJACENT TO VEHICULAR
PAVEMENTS
OVERFLOW RISER
OPTION (AS PER
PLAN)
8" MIN DEPTH
THICKENED CURB
ADJACENT TO
VEHICULAR
PAVEMENTS
STANDARD CROSS-SECTION
1
2
WALLED CROSS-SECTION
PONDING DEPTH MUST NOT
EXCEED FLOWLINE ELEVATION
OF ADJACENT GUTTER
18
"
M
I
N
4"
12"
M
A
X
30"
M
I
N
36" MIN
BASIN WIDTH
COVER PLATE
8"
SIDEWALK CHASE
18
"
M
I
N
OVERFLOW RISER OPTION (AS
PER PLAN)
REINFORCED CONCRETE
WALLS (AS PER PLAN)
4" MIN DEPTH OF DIAPHRAGM
AGGREGATE
8" MIN DEPTH OF
RESERVOIR AGGREGATE
18" MIN DEPTH OF BIORETENTION
SAND MEDIA
MAXIMUM ALLOWABLE
PONDING DEPTH IS 12" FROM
THE SURFACE OF THE MULCH
4" MIN DIAMETER PERFORATED
PVC UNDERDRAIN
6.UNDERDRAIN:
6.1.UNDERDRAIN PIPE TO BE PERFORATED OR SLOTTED. PERFORATIONS OR SLOTS TO BE SMALLER THAN SURROUNDING AGGREGATE TO ENSURE AGGREGATE DOES NOT FALL INTO OR CLOG THE OPENINGS.
6.2.DO NOT WRAP UNDERDRAIN WITH GEOTEXTILE OR SOCK.
6.3.UNDERDRAIN PIPE MUST OUTFALL BY GRAVITY AND MUST TIE INTO A STORMWATER PIPE, INLET OR SYSTEM AND THE LOCATION MUST BE APPROVED BY THE CITY. THE UNDERDRAIN TIE-IN SHALL MEET ALL REQUIRED PIPE SIZE,
TYPES, AND COVER REQUIREMENTS THAT MAY APPLY TO PIPING THAT EXTENDS BEYOND THE LIMITS OF THE BIORETENTION CELL AND ENCROACHES INTO PUBLIC RIGHT-OF-WAY OR OTHER PROPERTY.
7.OVERFLOW INLET:
7.1.A 100-YEAR OVERFLOW SPILLWAY OR INLET MUST BE PROVIDED.
7.2.ALL OVERFLOW INLETS SHALL BE CAPPED WITH A DOME-SHAPED GRATE, OR PER PLAN.
7.3.IN ALL CASES, AN EMERGENCY OVERFLOW ROUTE SHALL BE PROVIDED AND THE LOCATION SHALL BE IDENTIFIED ON THE PLANS (THIS MAY BE COINCIDENT WITH THE 100-YEAR OVERFLOW SPILLWAY).
8.CLEANOUTS:
8.1.PROVIDE CLEANOUTS (AS PER PLAN) TO ALLOW INSPECTION (BY CAMERA) OF THE UNDERDRAIN SYSTEM DURING AND AFTER CONSTRUCTION.
8.2.CLEANOUTS SHALL BE PROVIDED AT EACH BEND GREATER THAN OR EQUAL TO 90° AND EVERY 100' ALONG A STRAIGHT RUN. CLEANOUT SHALL BE INSTALLED PER THE APPROVED PLANS.
8.3.CLEANOUTS SHALL BE A SOLID WALL PVC STRUCTURE FOR ALL VERTICAL SECTIONS WITH FITTINGS TO CONNECT TO DISTRIBUTION AND UNDERDRAIN PIPING MATERIALS, AS REQUIRED.
9.FOREBAY:
9.1.THE FOREBAY SHALL BE EASILY ACCESSIBLE WITH A HARD SURFACED BOTTOM FOR MAINTENANCE PURPOSES.
9.2.THE FOREBAY SHOULD NOT EXTEND INTO THE SAND MEDIA TO PREVENT ANY SETTLING OF THE FOREBAY.
10.LANDSCAPE MATERIALS
10.1.CONTRACTOR SHALL NOT PLACE WEED BARRIER ANYWHERE WITHIN THE BIORETENTION BASIN. IF MULCH IS PLACED IN THE BIORETENTION BASIN, IT MUST BE NON-FLOATABLE.
10.2.IF MULCH OR COBBLES ARE PLACED IN THE BIORETENTION BASIN, THE MAXIMUM ALLOWABLE WATER DEPTH OF 12" AND REQUIRED BASIN VOLUME MUST BE MEASURED FROM THE TOP SURFACE OF THE MULCH OR COBBLE.
10.3.ROLLED TURF OR SOD IS NOT AN ALLOWABLE LANDSCAPE MATERIAL FOR BIORETENTION BASINS. LOW WATER CONSUMPTION LANDSCAPE PLANTINGS ARE PREFERRED FOR BIORETENTION BASINS.
10.4.LANDSCAPE PLANTINGS SHALL NOT BE PLACED TO IMPEDE DRAINAGE INTO OR OUT OF THE BIORETENTION BASIN.
10.5.TEMPORARY IRRIGATION MAY BE INSTALLED TO ESTABLISH LANDSCAPING OR SEED IN THE BIORETENTION BASIN.
2"
M
I
N
8" M
I
N
4"
FLAT
FOREBAY IS REQUIRED TO BE
PLACED AT CONCENTRATED
INFLOW LOCATIONS; PER PLANS
AND SITE SPECIFIC DETAILS
LANDSCAPING TO BE
INSTALLED PER APPROVED
LANDSCAPING PLAN
6"-
1
2
"
4" MIN DEPTH OF DIAPHRAGM
AGGREGATE
8" MIN DEPTH OF
RESERVOIR AGGREGATE 8"
M
I
N
4" MIN DIAMETER
PERFORATED PVC
UNDERDRAIN
2"
M
I
N
30
"
M
I
N
GEOTEXTILE FABRIC OR
LINER (AS PER PLAN)
18" MIN DEPTH OF
BIORETENTION SAND MEDIA
NATIVE SOIL
ZONE
RUNDOWN OR SCOUR
PROTECTION NEEDED ON
SLOPES
8"
FLAT AREA - SEE DESIGN PLANS
FOR EXTENTS OF BIORETENTION
FLAT SURFACES
TYPICAL
BIORETENTION OR
SAND FILTER
CROSS-SECTION
UPTURNED
ELBOW
DAYLIGHT ELEVATION AND
THE UNDERDRAIN MUST
BE BELOW THE BIOSAND
MEDIA OF THE LID
FEATURE
UNDERDRAIN @ 0.50%
MIN SLOPE
1.CONTRACTOR SHALL INSTALL BIORETENTION BASINS ACCORDING TO THE APPROVED PLANS AND/OR CONSTRUCTION
SPECIFICATIONS.
2.THIS DETAIL SHALL BE USED IN CONJUNCTION WITH DETAIL D-53 OR D-54. PLEASE REFER TO RAIN GARDEN/SAND FILTER DETAIL
FOR THE BIOMEDIA STRUCTURE.
3.THIS OPTION IS ONLY FOR USE WITH SYSTEMS THAT DO NOT HAVE AN IMPERMEABLE LINER.
NOTES:
30"
M
I
N
12"
M
A
X
18
"
M
I
N
4"
8" M
I
N
D5
DR
A
I
N
A
G
E
D
E
T
A
I
L
S
21
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
2'
TOP OF WEIR
2'WLW
2-#5 BARS
1
4
(SEE NOTE)
8" MINIMUM THICKNESS
2-#5 BARS3"
C
L
R
3"
C
L
R
NOTE:
TRENCH FOR WEIR OUTLET STRUCTURE USING NATIVE GROUND AS FORM WORK.
CONSTRUCT WEIR 8" MINIMUM THICKNESS. UPON COMPLETION OF TRENCHING,
PLACE TEMPERATURE STEEL AND CONCRETE IMMEDIATELY. FORM TOP 4".
TOP OF
BERM/EMBANKMENT
30" MIN.
OVERFLOW WEIR SCHEDULE401
H
Weir Summary
Rain Garden ID L (FT)H (FT)W (FT)
1 15 1 4
2 10 1 4
PART 1 - GENERAL
A.Bioretention Sand Media (BSM) shall be uniformly mixed,
uncompacted, free of stones, stumps, roots, or other similar objects
larger than two inches. No other materials or substances shall be
mixed or dumped within the bioretention area that may be harmful to
plant growth or prove a hindrance to the facility's function and
maintenance.
B.BSM shall be free of plant or seed material of non-native, invasive
species, or weeds.
C.Fully mixed BSM shall be tested prior to installation and meet the
following criteria:
1.P-Index of less than 30
2.pH of 5.5-6.5. Should pH fall outside of the acceptable range, it
may be modified with lime (to raise) or iron sulfate plus sulfur (to
lower). The lime or iron sulfate must be mixed uniformly into the
BSM prior to use in the bioretention facility.
3.Cation Exchange Capacity (CEC) greater than 10
4.Phosphorous (Phosphate, P2O5) not to exceed 69 ppm
5.BSM that fails to meet the minimum requirements shall be replaced
at the Contractor's expense.
D.BSM shall be delivered fully mixed in a drum mixer. Onsite mixing of
piles will not be allowed. Mixing of the BSM to a homogeneous
consistency shall be done to the satisfaction of the Owner.
PART 2 - SOIL MATERIALS
A.Sand
1.BSM shall consist of 60-70% sand by volume meeting ASTM C-33.
B.Shredded Paper
1.BSM shall consist of 5-10% shredded paper by volume.
2.Shredded paper shall be loosely packed, approximate bulk density
of 50-100 lbs/CY.
3.Shredded paper shall consist of loose leaf paper, not shredded
phone books, and shall be thoroughly and mechanically mixed to
prevent clumping.
C.Topsoil
1.BSM shall consist of 5-10% topsoil by volume.
2.Topsoil shall be classified as sandy loam, loamy sand, or loam per
USDA textural triangle with less than 5% clay material.
3.Onsite, native material shall not be used as topsoil.
4.Textural analysis shall be performed on topsoil, preferably at its
source, prior to including topsoil in the mix. Topsoil shall be free of
subsoil, debris, weeds, foreign matter, and any other material
deleterious to plant health.
5.Topsoil shall have a pH range of 5.5 to 7.5 and moisture content
between 25-55%.
6.Contractor shall certify that topsoil meets these specifications.
D.Leaf Compost
1.BSM shall consist of 10-20% leaf compost by volume.
2.Leaf compost shall consist of Class 1 organic leaf compost
consisting of aged leaf mulch resulting from biological degradation
and transformation of plant-derived materials under controlled
conditions designed to promote aerobic decomposition.
3.The material shall be well composted, free of viable weed seeds
and contain material of a generally humus nature capable of
sustaining growth of vegetation, with no materials toxic to plant
growth.
4.Compost shall be provided by a local US Composting Council Seal
of Testing Assurance (STA) member. A copy of the provider's
most recent independent STA test report shall be submitted to and
approved by the Owner prior to delivery of BSM to the project site.
5.Compost material shall also meet the following criteria:
a.100 percent of the material shall pass through a 1/2 inch
screen
b.PH of the material shall be between 6.0 and 8.4
c.Moisture content shall be between 35 and 50 percent
d.Maturity greater than 80 percent (maturity indicator expressed
as percentage of germination/vigor, 80+/80+)
e.Maturity indicator expressed as Carbon to Nitrogen ration < 12
f.Maturity indicator expressed as AmmoniaN/NitrateN Ratio <4
g.Minimum organic matter shall be 40 percent dry weight basis
h.Soluble salt content shall be no greater than 5500 parts per
million or 0-5 mmhos/cm
i.Phosphorus content shall be no greater than 325 parts per
million
j.Heavy metals (trace) shall not exceed 0.5 parts per million
k.Chemical contaminants: meet or exceed US EPA Class A
standard, 40 CFR 503.13, Tables 1 & 3 levels
l.Pathogens: meet or exceed US EPA Class A standard, 40 CFR
503.32(a) levels
PART 3 - EXECUTION
A.General
1.Refer to project specifications for excavation requirements.
B.Placement Method
1.BSM material shall be spread evenly in horizontal layers.
2.Thickness of loose material in each layer shall not exceed
9-inches.
3.Compaction of BSM material is not required.
CLEANOUT403
BIORETENTION SAND MEDIA404
APPROVED:
DRAWN BY:DETAILS
CONSTRUCTION DATE REVISED:
DETAILSTORMWATER
BIORETENTION
JUNE 2023
SAA
D-53
402 TYPICAL BIORETENTION DETAIL
APPROVED:
DRAWN BY:DETAILS
CONSTRUCTION DATE REVISED:
DETAILSTORMWATER
BIORETENTION - UPTURNED ELBOW OUTFALL
D-53AJUNE 2023
SAA
UPTURNED ELBOW DETAIL (RAIN GARDEN 2)403
D6
DE
T
A
I
L
S
SI
T
E
22
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
Cross section of post
SW SAMPLE AVE
2400
*12 Gauge
CRITERIA FOR SINGLE POST
Max. Sign
Panel
Telespar 22F12A O3PG
Anchor Post *
Telespar 20F12P-10PG
Post *
36"x36"2.25"x2.25"x3'-0"2"x2"x12'-0"
NOTES:
1. Attach the sign panels tightly to the post and use oversized washers to keep the sign from breaking loose
from the post when hit by a vehicle.
2. Sign panels should be mounted a minimum of 7 feet above the pavement or ground.
3. Signs larger than 36 inches in length or width require wind bracing and special post design.
4. Anchor Stub and post are square steel tube (perforated).
5. All "No Parking" signs shall be installed at 45° from Flow Line.
6. R1-1 "STOP" sign 30" High Density/Diamond Grade.Sign mounted to post with 1each drive rivet with nylon
washer against sign face (on Top of the Sign). sign shall be mounted with 1 each 5/16"x2 1/2" Hew Bolt with
nylon washers against sign face (on Bottom of the Sign). Secured with 1 each 5/16" Hex Nut on the back
side of Post.
7. 4" Core Drill in Asphalt or Concrete or provide a 4" PVC sleeve cut flush to the surface for placement of
anchor post. Voids to be filled in with sand or other fine suitable material.
SW SAMPLE AVE
2400
ATTACHED SIDEWALK DETACHED SIDEWALK
8"
8"
30
"
7'
-
0
"
3' (min.)
BOC
(m
i
n
.
)
C
l
e
a
r
a
n
c
e
3'
2 each 8" Blades mounted to Post
with 4 each Drive Rivets with Nylon
Washers
8"
30
"
7'
-
0
"
1'
8"
3'
3" - 6" Above Grade (TYP)
(m
i
n
.
)
C
l
e
a
r
a
n
c
e
(min.)
Telespar Post
4" - 6" Below Grade (TYP)
Concrete or AsphaltSand or other
fine suitable material
SW
Sa
m
p
l
e
Av
e
24
0
0
NO
T
E
S
:
1.
S
t
r
e
e
t
n
a
m
e
m
u
s
t
b
e
6
"
(
m
i
n
.
)
w
h
i
t
e
l
e
t
t
e
r
s
,
f
i
r
s
t
l
e
t
t
e
r
o
f
e
a
c
h
s
t
r
e
e
t
n
a
m
e
w
o
r
d
t
o
b
e
c
a
p
i
t
a
l
i
z
e
d
f
o
l
l
o
w
e
d
b
y
a
l
l
lo
w
e
r
c
a
s
e
l
e
t
t
e
r
s
,
F
H
W
A
S
e
r
i
e
s
"
B
"
.
2.
P
r
e
f
i
x
m
u
s
t
b
e
2
"
l
e
t
t
e
r
s
,
F
H
W
A
S
e
r
i
e
s
"
B
"
a
n
d
p
l
a
c
e
d
o
n
t
h
e
u
p
p
e
r
l
e
f
t
.
3.
S
u
f
f
i
x
m
u
s
t
b
e
2
"
(
m
i
n
.
)
l
e
t
t
e
r
s
a
n
d
b
l
o
c
k
n
u
m
b
e
r
m
u
s
t
b
e
2
"
(
m
i
n
.
)
n
u
m
b
e
r
s
,
F
H
W
A
S
e
r
i
e
s
"
B
"
.
4.
O
v
e
r
a
l
l
s
i
g
n
l
e
n
g
t
h
d
i
m
e
n
s
i
o
n
v
a
r
i
e
s
a
c
c
o
r
d
i
n
g
t
o
l
e
n
g
t
h
o
f
s
t
r
e
e
t
n
a
m
e
.
5.
A
l
l
s
i
g
n
l
e
t
t
e
r
i
n
g
a
n
d
g
r
e
e
n
b
a
c
k
g
r
o
u
n
d
m
a
t
e
r
i
a
l
m
u
s
t
b
e
a
t
l
e
a
s
t
3
M
H
i
g
h
I
n
t
e
n
s
i
t
y
G
r
a
d
e
P
r
i
s
m
a
t
i
c
R
e
f
l
e
c
t
i
v
e
Sh
e
e
t
i
n
g
(
H
I
P
)
w
i
t
h
a
n
E
C
T
r
a
n
s
p
a
r
e
n
t
O
v
e
r
l
a
y
F
i
l
m
s
h
e
e
t
i
n
g
p
e
r
F
H
W
A
;
No
s
i
l
k
s
c
r
e
e
n
e
d
s
i
g
n
s
w
i
l
l
b
e
pe
r
m
i
t
t
e
d
.
6.
S
t
r
e
e
t
n
u
m
b
e
r
s
s
h
a
l
l
a
l
w
a
y
s
p
o
i
n
t
t
o
h
i
g
h
e
r
b
l
o
c
k
n
u
m
b
e
r
.
7.
A
l
u
m
i
n
u
m
s
i
g
n
b
l
a
n
k
s
h
a
l
l
b
e
0
.
0
8
t
h
i
c
k
n
e
s
s
w
i
t
h
3
/
4
"
r
a
d
i
u
s
c
o
r
n
e
r
s
.
S
i
g
n
s
l
o
n
g
e
r
t
h
a
n
3
6
"
s
h
a
l
l
b
e
0
.
1
0
t
h
i
c
k
.
8.
L
o
v
e
l
a
n
d
o
n
l
y
,
s
i
g
n
a
l
i
z
e
d
i
n
t
e
r
s
e
c
t
i
o
n
s
i
g
n
s
s
h
a
l
l
b
e
1
8
"
(
m
i
n
.
)
i
n
h
e
i
g
h
t
w
i
t
h
1
5
"
h
i
g
h
l
e
t
t
e
r
s
.
9.
A
l
l
s
t
r
e
e
t
n
a
m
e
s
i
g
n
s
s
h
a
l
l
b
e
r
e
t
r
o
r
e
f
l
e
c
t
i
v
e
.
1/
2
"
Le
n
g
t
h
V
a
r
i
e
s
b
y
S
t
r
e
e
t
N
a
m
e
1/
2
"
2-
1
/
4
"
1/
2
"
2-
3
/
4
"
8"
1"
m
i
n
.
2"
m
a
x
.
1/
2
"
3-
3
/
4
"
1/
2
"
1/
2
"
1"
m
i
n
.
2"
m
a
x
.
2-
3
/
4
"
6"
H
w
y
B
S
e
r
i
e
s
2"
H
w
y
B
S
e
r
i
e
s
,
Ce
n
t
e
r
e
d
o
n
L
o
g
o
2"
H
w
y
B
S
e
r
i
e
s
2"
H
w
y
B
S
e
r
i
e
s
Flare
1. No joints are allowed in the flowline. Six inch wide curb or "dummy joint" may be tooled no closer than 6 inches
from flow line as shown.
2. Pedestrian landing area required 4 ft length x 4 ft width, max slope in any direction is 1:50 or 14" per foot.
3. Joint pattern to be according to intersection gutter detail' or as determined by the local entity.
4. Wood float finish is required over the sloped surface of ramp and flares.
5. Minimum ramp width shall be four feet, or the same as the widest adjacent sidewalk, whichever is greater, up to a
maximum width of 8 feet.
6. Detectable warning is to extend full width of the ramp and be a minimum of 2.0' in the direction of travel. Material
to be approved by local engineer
7. T = Concrete thickness, 6" minimum for entire ramp area.
SECTION A-A
PLAN VIEW
N.T.S.
N.T.S.
NOTES:
2' Transition (TYP.)
4' (min)
6"
2'
1:20 (max)
1:12 (ma
x
)
T, See Note 8
0" Curb
Lip of Gutter
Detectable
Warning
A
A
1/2" per ft.
1" per ft.
Flare
Curb
Flare Detectable Warning
Curb
(TYP.)SIDEWALK
SI
D
E
W
A
L
K
0" Curb Height,
See Section A-A
(TYP)
Standard Curb
and Gutter,
See Standard
Dwg 701 (TYP)
Pedestrian
Landing Area,
See Note 2
2' (min)
C
u
r
b
Fl
a
r
e
Varies
Cu
r
b
Fl
a
r
e
Ra
m
p
C
u
r
b
Curb
Fl
a
r
e
Ra
m
p
Varies
Pa
n
e
l
s
Pa
n
e
l
s
6"
Ra
m
p
Wi
d
t
h
:
4.
5
'
5.
0
'
6.
0
'
7.
0
'
8.
0
'
No
t
e
:
Tr
u
n
c
a
t
e
d
d
o
m
e
p
a
n
e
l
s
a
r
e
av
a
i
l
a
b
l
e
i
n
2
'
x
2
'
s
q
u
a
r
e
s
an
d
2
'
x
2
.
5
'
r
e
c
t
a
n
g
l
e
s
.
Co
m
b
i
n
e
t
h
e
w
i
d
t
h
s
t
o
f
i
t
th
e
r
a
m
p
.
P
a
n
e
l
s
m
a
y
b
e
cu
t
t
o
n
o
l
e
s
s
t
h
a
n
a
2
'
x
1
.
5
'
si
z
e
.
Pa
n
e
l
W
i
d
t
h
Co
m
b
i
n
a
t
i
o
n
s
:
2'
+
2
.
5
'
2.
5
'
+
2
.
5
'
2'
+
2
'
+
2
'
2.
5
'
+
2
'
+
2
.
5
'
2'
+
2
'
+
2
'
+
2
'
No
t
e
s
:
1
.
T
r
u
n
c
a
t
e
d
d
o
m
e
w
a
r
n
i
n
g
p
a
n
e
l
:
In
s
t
a
l
l
p
a
n
e
l
s
a
l
o
n
g
w
i
t
h
t
h
e
co
n
c
r
e
t
e
p
o
u
r
f
o
r
t
h
e
r
a
m
p
.
Sp
e
c
i
f
i
c
a
t
i
o
n
s
f
o
r
t
h
e
p
a
n
e
l
a
n
d
in
s
t
a
l
l
a
t
i
o
n
i
n
s
t
r
u
c
t
i
o
n
s
w
i
l
l
b
e
pr
o
v
i
d
e
d
u
p
o
n
r
e
q
u
e
s
t
.
2
.
T
h
i
s
d
r
a
w
i
n
g
s
h
o
w
s
v
e
r
t
i
c
a
l
c
u
r
b
.
Fo
r
D
r
i
v
e
O
v
e
r
C
u
r
b
t
h
e
w
a
r
n
i
n
g
de
t
e
c
t
i
o
n
l
o
c
a
t
i
o
n
s
h
a
l
l
b
e
p
l
a
c
e
d
i
n
th
e
s
a
m
e
p
o
s
i
t
i
o
n
6
"
b
a
c
k
f
r
o
m
t
h
e
ba
c
k
o
f
c
u
r
b
.
3
.
I
f
c
u
r
b
a
n
d
g
u
t
t
e
r
a
r
e
p
o
u
r
e
d
mo
n
o
l
i
t
h
i
c
w
i
t
h
r
a
m
p
,
p
l
a
c
e
d
o
m
e
ed
g
e
a
t
b
a
c
k
o
f
c
u
r
b
a
s
s
h
o
w
n
.
I
f
no
t
p
o
u
r
e
d
m
o
n
o
l
i
t
h
i
c
,
p
l
a
c
e
d
o
m
e
ed
g
e
6
"
f
r
o
m
b
a
c
k
o
f
c
u
r
b
.
Ca
s
e
1
-
D
i
r
e
c
t
i
o
n
a
l
R
a
m
p
s
Ca
s
e
2
-
N
o
n
-
D
i
r
e
c
t
i
o
n
a
l
R
a
m
p
s
Varies
Pa
n
e
l
s
Ra
m
p
Pa
n
e
l
s
Fl
a
r
e
Cu
r
b
Ca
s
e
3
-
M
i
d
-
B
l
o
c
k
R
a
m
p
s
6"
Pa
n
e
l
s
Pa
n
e
l
s
Fl
a
r
e
6"
Fl
a
r
e
Varies
FORT COLLINS ONLY
Aligned with
Pedestrian flow
Gu
t
t
e
r
or Ap
r
o
n
℄Ce
n
t
e
r
l
i
n
e
o
f
r
a
m
p
BO
C
-
B
a
c
k
o
f
C
u
r
b
FO
C
-
F
a
c
e
o
f
C
u
r
b
-F
l
o
w
l
i
n
e
Varies
2'-0"
2'-0"
A A
FOC or ℄
2'-0"
BO
C
BO
C
1:
1
2
m
a
x
s
l
o
p
e
1:
2
0
sl
o
p
e
Pa
n
e
l
s
e
m
b
e
d
d
e
d
i
n
t
h
e
co
n
c
r
e
t
e
r
a
m
p
s
Se
c
t
i
o
n
A
-
A
(
C
e
n
t
e
r
l
i
n
e
o
f
r
a
m
p
)
NT
S
Flow line Curb
and Gutter
BOC
See Note 3
NOTES:
1. THE SIGN PLATE SHALL BE A MINIMUM OF 12"X18" WITH A THICKNESS OF .080
ALUMINUM CONSTRUCTION.
2. THE SIGN FACE SHALL HAVE A WHITE REFLECTIVE BACKGROUND WITH A RED
LEGEND. USE THE STANDARD 3M SCOTCHLITE SIGN FACE NUMBER R7-32 OR
EQUIVALENT, WITH RED LETTERING AS SHOWN ABOVE.
3. ARROWS MAY BE NEEDED (LEFT, RIGHT OR DOUBLE), TO DESIGNATE BEGIN AND END OF
NO PARKING AREA.
FIRE
LANE
NO
PARKING
STANDARD
FIRE LANE SIGN DETAIL
UNIVERSAL
FIRE LANE SIGN DETAIL
18"
2"
1 1/2"
12"12"
FIRE LANE
COLOR SCHEDULE
BACKGROUND
"P"
RED
WHITE
BLACK
LEGEND, CIRCLE DIAGONAL, BORDER,
"ARROW", "FIRE LANE"
(FORT COLLINS ONLY)
Transition back of walk (typ.)
Broom finishBroom finish
SECTION A-A
MID-BLOCK LOCATION
Varies *
1:12
Slope
(max.)
1:50 see note 2
Fl
o
w
l
i
n
e
(max.)
Slope
1:12
5'
A
Varies *
Wood float finish thru ramp
Slo
p
e
1:1
2
Slope
1:12
CORNER LOCATION
ramp
finish thru
Wood float
Broom finish
A
Varie
s
*
(max
.
)
A
A
5'
(m
a
x
)
(Radius varies)
(typ.)
back of walk
Transition
2
Br
o
o
m
f
i
n
i
s
h
BA
C
K
O
F
W
A
L
K
/
L
A
N
D
I
N
G
Retaining Curb (Optional)
12
"
(m
a
x
.
)
(m
i
n
.
)
T
Walk
Curb
Gutter
NOTES:
1. T = Concrete thickness, 6" minimum for entire ramp area.
2. 1:50 Max unless a landing behind ramp (then ramp can be 1:12 with 1:20 on the detectable warning).
3. See CONST. DWG. 1606(a) and 1607 for Fort Collins.
4. Detectable Warning to extend the full width of the ramp. Material to be approved by Local Engineer.
5. 0" Curb height, See Section A-A.
6. Standard Curb and Gutter Section , See Standard Drawing 701.
2'-0" (min)
6"
Walk
Gutter
Curb
Va
r
i
e
s
*
Detectable Warning
1/4" per ft.
1" per ft.1" per ft.
1"
p
e
r
f
t
.
1" pe
r
f
t
.
On a radius hold 6" at the
corners of the truncated
dome warning.
2"
Retaining
Curb
(Optional)
6"
* Curb to match slope
of sidewalk, Ramp length
not to exceed 15'-0"
See Note 6
See Note 5
See Note 5
See Note 6
Detectable Warning,
See Note 4
Detectable Warning,
See Note 4
Retaining Curb (Optional)
to retain ground behind
the walk, if needed
500
PAVING SECTIONS
(PRIVATE AREAS OUTSIDE ROW)
NOTES:
1.ALL SITE GRADING, SUBGRADE PREPARATION AND PAVING SHALL FOLLOW THE GEOTECHNICAL
RECOMMENDATIONS CONTAINED IN THE REPORT BY CTL THOMPSON., TITLED "GEOTECHNICAL INVESTIGATION
HIBDON/MASON 24/7 SHELTER SWC HIBDON COURT AND MASON STREET FORT COLLINS, COLORADO" (CTL
PROJECT NUMBER:FC10,520.000-125-R1), DATED NOVEMBER 20, 2023.
2.NOTE THAT THESE PAVING SECTIONS ARE TO BE USED ONLY FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY.
PAVING SECTIONS WITHIN PUBLIC RIGHT-OF-WAY WILL BE REQUIRED BY THE CITY OF FORT COLLINS TO BE
PER AN APPROVED PAVEMENT DESIGN REPORT.
3.SEE CDOT STANDARD M-412-1 FOR TYPICAL CONCRETE PAVING JOINT LAYOUT.
4.CONCRETE PARKING LOT SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 330R-08.
5.ALL AREAS DEDICATED AS EMERGENCY ACCESS EASEMENTS SHALL BE CAPABLE OF SUPPORTING 80,000
POUNDS.
PAVEMENT SECTION
6" PCC
6"
APPROVED
SUBGRADE
5" HOT MIX
ASPHALT
HEAVY DUTY
8"
APPROVED
SUBGRADE
4" HOT MIX
ASPHALT
PAVEMENT SECTION
LIGHT DUTY
6" PCC
FDC
UD
EM
GM
UDUDUD
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
X X X X
X X X X X X X
FE S
FE S
XX
X
X
X
SSSSSS
S
S
S
S
S
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUD
UD
UD
UD
U
D
U
D
UD
U
D
U
D
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
E
V
X X X X
X X X X X X X
FE S
FE S
XX
X
X
X
SSSSSS
S
S
S
S
S
S
S
N
M
A
S
O
N
S
T
R
E
E
T
HIBDON COURT
INTERIM HICKORY REGIONAL
DETENTION POND
LOT 1
LOT 2
LOT 3
LOT LINE
CURB CUT AND
SIDEWALK CHASE
EXISTING 24"
STORM CULVERT
TOTAL LENGTH
OF SILT FENCE
=1433 LF
71' ROW
71' ROW
42'' FL-FL
42'' FL-FL
LOD
LOD
LODLODLOD
LO
D
LOD
LO
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
L
O
D
S
F
S
F
S
F
SF
SF
SFSFSF
SF
SF
SF
S
F
S
F
S
F
S
F
S
F
S
F
S
F
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF SF SF SF SF SF SF SF
SF
SF
SF
SF
S
F
S
F
S
F
S
F
S
F
S
F
S
F
5,000 SQ. FT
STABILIZED
STAGING AREA
CONCRETE
FOREBAY
CONCRETE
FOREBAY
SCOURSTOP
(PER MASON STREET
INFRASTRUCTURE
PACKAGE)
655 SQ. FT.
TMAX EROSION
CONTROL BLANKET
GROUNDWATER
MONITORING WELL
NATURAL HABITAT
BUFFER ZONE
8.8%
6.5%
10.0%
2.
7
%
2.0%
6.8
%
2.1%
3.8%
12
.
3
%
2
.
2
%
2.0
%
3.
7
%
10
.
5
%
8.
4
%
9.0%
1.3%
1.4%
2.
0
%
1.
9
%
2.3%
8.
1
%
2.7%
2.1
%
2.3
%
4
:
1
4:
1
6
:
1
4
:
1
4
:
1
7:1
3:1
(6
.
1
:
1
)
(8.3:1
)
(4.2:1)
(
6
.
5
:
1
)
(8
.
7
:
1
)
(5
.
2
:
1
)
(4.4
:
1
)
(4
.
8
:
1
)
(8.7
:
1
)
EC1
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
23
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
Sheet
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
b
y
a
P
r
o
f
e
s
s
i
o
n
a
l
E
n
g
i
n
e
e
r
i
n
th
e
e
m
p
l
o
y
o
f
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: FORT COLLINS RESCUE MISSION
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Flow Barriers (Wattles) *
Inlet Filter Bags *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Contour Furrows (Ripping / Disking)
Rock Bags *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Riprap
KEYMAP
HIBDON CT.
M
A
S
O
N
S
T
.
HICKORY ST.
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
SILT FENCE
ROCK SOCK
1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY
CRIMP MULCHING OR SIMILAR METHODS.
2.SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone________________________________
3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
4.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 14, 2024 BY
NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.
5.REFER TO LANDSCAPING PLAN FOR FINAL VEGETATIVE STABILIZATION IN
PLANTING AREAS.
6.THE NATURAL HABITAT BUFFER ZONE SHALL NOT BE DISTURBED BY ANY
GRADING, CONSTRUCTION OR MAINTENANCE ACTIVITIES EXCEPT AS
APPROVED BY THE CITY ENVIRONMENTAL PLANNER.
7.ALL PERMANENT AND TEMPORARY BMP'S ASSOCIATED WITH THE INTERIM
HICKORY REGIONAL POND SHALL BE INSTALLED PER THE "MASON STREET
INFRASTRUCTURE" EROSION CONTROL PLAN.
GENERAL NOTES:
WATTLE DIKE
CONCRETE WASH AREA
TMAX EROSION CONTROL
LEGEND:
BALE OUTLET PROTECTION
INLET PROTECTION
VEHICLE TRACKING CONTROL PAD
SF
SEED AND MULCH (SEE NOTE 5)
CALCULATIONS CHART
TOTAL DISTURBED PROJECT AREA 2.77 ACRES
TOTAL "ONSITE" AREA OF DISTURBANCE 2.77 ACRES
TOTAL "OFFSITE" AREA OF DISTURBANCE 0 ACRES
TOTAL STORAGE/STAGING AREA 0.11 ACRES
TOTAL HAUL ROADS AREA N/A
CONSTRUCTION VEHICLE TRAFFIC AREA N/A
EST. PERCENT OF PROJECT AREA EXPOSED 100%
EST. PERCENT VEGETATIVE COVER 100%DENSITY
EXISTING SOIL TYPE C
APPROX. GROUNDWATER DEPTH 8.0-9.5 FEET
NUMBER OF PHASES W/ PROJECT N/A
TOTAL VOLUME OF IMPORTED (+) / EXPORTED (-) MATERIALS 0 CU. YD.
TOTAL AREA OF STOCKPILING OF FILL OR BORROW AREAS OFF SITE 0 SQ. FEET
STEEPEST SLOPE 4:1 H:V
DISTANCE FROM A RIPARIAN AREA OR SENSITIVE AREA 0 FEET
CALCULATION CHART:
EC1
EC2
ER
O
S
I
O
N
C
O
N
T
R
O
L
D
E
T
A
I
L
S
24
Sheet
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
b
y
a
P
r
o
f
e
s
s
i
o
n
a
l
E
n
g
i
n
e
e
r
i
n
th
e
e
m
p
l
o
y
o
f
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
VTC
ROCK SOCK SECTION ROCK SOCK PLAN
ROCK SOCK JOINTING
GRADATION TABLE
SIEVE SIZE
MASS PERCENT
PASSING SQUARE
MESH SIEVES
NO. 4
2"100
1-1/2"90-100
1"20-55
3/4"0-15
3/8"0-5
MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR
CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,
ALL SIDES
RS
001 CONCRETE WASHOUT AREA 002 ROCK SOCK 003 VEHICLE TRACKING PAD
004 SILT FENCE
SF
CWA
005 CURB INLET PROTECTION
IP
POSTS
PREASSEMBLED SILT FENCE POSTS SHALL OVERLAP
AT JOINTS SO THAT NO
GAPS EXIST IN SILT FENCE.
NOTE:
THICKNESS OF GEOTEXTILE
HAS BEEN EXAGGERATED.POST SHALL BE JOINED AS SHOWN, THEN
ROTATED 180° IN DIRECTION SHOWN AND
DRIVEN INTO THE GROUND.
SILT FENCE JOINTS
DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18".
EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE
LINE OF POSTS AND UPSLOPE FROM THE BARRIER.
ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR
WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES,
ETC. SHALL BE USED.
NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE
BURIED IN THE TRENCH.
THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY
WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE
RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND.
SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY
LAND-DISTURBING ACTIVITIES.
USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY.
INSTALLATION NOTES:
1.
2.
3.
4.
5.
6.
7.
THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND
AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT
UPSTREAM SEDIMENT AS NECESSARY.
SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED
WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6".
SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS
STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY
DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND
MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY.
MAINTENANCE NOTES:
1.
2.
3.
4" MIN.
4" MIN.
1 12" x 1 12" WOODEN FENCE POSTS
SF
008
SECTION G-G
G
PLAN
G
BOP
BALE OUTLET PROTECTION
FL
O
W
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT THE SECOND
WATTLE TIGHTLY AGAINST THE FIRST, DO NOT OVERLAP THE ENDS. STAKE
THE WATTLES AT EACH END AND FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF THE WATTLE.
LEAVING 2 - 3 INCHES OF THE STAKE PROTRUDING ABOVE THE WATTLE. A
HEAVY SEDIMENT LOAD WILL TEND TO PICK THE WATTLE UP AND COULD
PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO LOW. IT MAY BE
NECESSARY TO MAKE A HOLE IN THE WATTLE WITH A PICK END OF YOUR
MADDOX IN ORDER TO GET THE STAKE THROUGH THE STRAW. WHEN
STRAW WATTLES ARE USED FOR FLAT GROUND APPLICATIONS, DRIVE THE
STAKES STRAIGHT DOWN; WHEN INSTALLING WATTLES ON SLOPES, DRIVE
THE STAKES PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT AN ANGLE
TOWARD THE FIRST WATTLE IN ORDER TO HELP ABUT THEM TIGHTLY
TOGETHER. IF YOU HAVE DIFFICULTY DRIVING THE STAKE INTO EXTREMELY
HARD OR ROCKY SLOPES, A PILOT BAR MAY BE NEEDED TO BEGIN THE
STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A"WATTLE "B"
1'2'
TYP.
1'1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER
AND ON EACH SIDE OF THE WATTLE. LEAVING 4"-6" OF
STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR
NYLON ROPE SHOULD BE TIED TO THE STAKES ACROSS
THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL THE
BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO
THE WATTLE.
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, TO
PREVENT SHIFTING, BUTT THE SECOND WATTLE TIGHTLY
AGAINST THE FIRST. DO NOT OVERLAP THE ENDS. STAKES
SHOULD BE DRIVEN 1 FT. FROM END, ACROSS FROM AND
ON EACH SIDE OF WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR
NYLON ROPE SHOULD BE TIED TO STAKES IN AN HOUR
GLASS FORMATION (FRONT TO BACK OF WATTLE "A",
ACROSS TO FRONT OF WATTLE "B", ACROSS TO BACK AND
BACK TO FRONT OF WATTLE "A"). STAKES SHOULD THEN BE
DRIVEN IN UNTIL BAILING WIRE OR NYLON ROPE IS
SUFFICIENTLY SNUG TO THE WATTLE.
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO PREVENT
PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE MAIN
FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER TOGETHER;
FOR HARD, ROCKY SOILS - ADJUST THE ROWS FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO WATTLES IS
ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
10. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO USE A
STAKE THAT IS LONG ENOUGH TO PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL. FOR SOFT
LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
1"x 1" WOOD STAKES
18"-24"
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT
FIBERS SHALL BE USED WHEN
INSTALLATION COMES IN CONTACT WITH A
WATER BODY.
007 STRAW WATTLE
SLOPE
INSTALLATION
DETAIL
Drawing Not To Scale
1.Prepare soil before installing rolled
erosion control products (RECPs),
including any necessary
application of lime, fertilizer, and
seed.
2.Begin at the top of the slope by
anchoring the RECPs in a
6"(15cm) deep X 6"(15cm) wide
trench with approximately 12"
(30cm) of RECPs extended beyond
the up-slope portion of the trench.
Anchor the RECPs with a row of
staples/stakes approximately 12"
(30cm) apart in the bottom of the
trench. Backfill and compact the
trench after stapling. Apply seed to
the compacted soil and fold the
remaining 12"(30cm) portion of
RECPs back over the seed and
compacted soil. Secure RECPs
over compacted soil with a row
of staples/stakes spaced
approximately 12"(30cm) apart
across the width of the RECPs.
3.Roll the RECPs (A) down or (B)
horizontally across the slope.
RECPs will unroll with appropriate
side against the soil surface. All
RECPs must be securely fastened
to soil surface by placing
staples/stakes in appropriate
locations as shown in the staple
pattern guide.
4.The edges of parallel RECPs must
be stapled with approximately 2" -
5" (5-12.5cm) overlap depending
on the RECPs type.
5.Consecutive RECPs spliced down
the slope must be end over end
(Shingle style) with an approximate
3"(7.5cm) overlap. Staple through
overlapped area, approximately
12"(30cm) apart across entire
RECPs width.
Drawn on: 3-16-11
Disclaimer:
The information presented herein is general design information only. For specific applications,
consult an independent professional for further design guidance.
2"-5"
(5-12.5cm)
3B
4
2
5
1
3A
12"(30cm)
6"
(15cm)
6"
(15cm)
*NOTE:
In loose soil conditions, the use of
staple or stake lengths greater than
6"(15cm) may be necessary to
properly secure the RECP's.
3"(7.5cm)
5401 St. Wendel - Cynthiana Rd.
Poseyville, IN 47633
PH: 800-722-2040
www.nagreen.com
006 TMAX EROSION BLANKET
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
ELEC
F
CTV
CTV CTV CTV CTV CTV
OHU OHU OHU OHU
CTV
X X X X
X X X X X X X
CTV
G G G
G G G G G G
SS SS SS SS SS SS
HY D
S
FE
S
FE
S
XX
X
X
X
X
W W W W W W W
W W
SSSSSS
S
S
S
S
S
S
W W
S
S
UDUDUDUDUDUDUDUDUDUDUDUDUD
UD
UD
UD
U
D
U
D
UD
U
D
U
D
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
E
V
UD
S
C
TF
G
G
UDUDUD
GEN
10' UTILITY EASEMENT
BK 1658 PG 746
45' ROW
BK 1743 PG 632
10' UTILITY EASEMENT
BK 1572 PG 322
N
M
A
S
O
N
S
T
R
E
E
T
a1
HIBDON COURT
45' ROW
BK 1743 PG 632
10' UTILITY
EASEMENT
30' STORMWATER &
UTILITY EASEMENT
WANKIER LANCE
1401 N. COLLEGE AVENUE
FORT COLLINS, CO
WOOD RONALD G/ JENNIFER
L/ WILLARD E
122 HIBDON COURT
FORT COLLINS, CO
THOMPSON PROPERTIES LLC
1319 N. COLLEGE AVENUE
FORT COLLINS, CO
a2
a3
b3
b2
b1
60' DRAINAGE
EASEMENT
EMERGENCY SPILLWAY
EMERGENCY SPILLWAY
4' CURB CUT AND
SIDEWALK CHASE
STORM DRAIN
(TYP.)
HICKORY REGIONAL
DETENTION POND
LOT 1
LOT 3
LOT 2
RAIN GARDEN 2
REQ VOL. 682 CUFT
PROVIDED VOL. 915 CUFT
PROVIDED FLAT AREA = 1,532 SQFT
RAIN GARDEN 1
REQ VOL. 1,405 CUFT
PROVIDED VOL. 1,870 CUFT
PROVIDED FLAT AREA = 1,442 SQFT
0.09 ac.
R1
0.09 ac.
R3
0.11 ac.
R5
0.27 ac.
B1
0.36 ac.
A2
0.32 ac.
A1
0.37 ac.
A3
0.11 ac.
A4
0.04 ac.
A5
0.35 ac.
C1
0.03 ac.
B4
0.19 ac.
B2
0.04 ac.
A6
0.06 ac.
A7
0.24 ac.
B30.02 ac.
R2
0.17 ac.
R4
0.02 ac.
R12
0.04 ac.
R6
0.02 ac.
R7
0.03 ac.
R8
0.10 ac.
R10
0.07 ac.
R9 0.04 ac.
R11
b1
r1 r3
r2
b4
r5
r4
c1
r10
r11
r9
r8
r7
a5
a6
r6
a7
r12
1' CURB CUT AND
SIDEWALK CHASE
1' CURB CUT AND
SIDEWALK CHASE
CONCRETE RUNDOWN
AND FOREBAY 1-1
SEE DETAIL SHEET 21
CONCRETE FOREBAY 1-3
SEE DETAIL SHEET 21
CONCRETE FOREBAY 1-4
SEE DETAIL SHEET 21
CONCRETE RUNDOWN
AND FOREBAY 1-2
SEE DETAIL SHEET 21
CONCRETE RUNDOWN
AND FOREBAY 2-1
SEE DETAIL SHEET 21
CONCRETE FOREBAY 2-2
SEE DETAIL SHEET 21
CONCRETE FOREBAY 2-3
SEE DETAIL SHEET 21
DR1
DR
A
I
N
A
G
E
E
X
H
I
B
I
T
25
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
Sheet
FO
R
T
C
O
L
L
I
N
S
R
E
S
C
U
E
M
I
S
S
I
O
N
Th
e
s
e
d
r
a
w
i
n
g
s
a
r
e
in
s
t
r
u
m
e
n
t
s
o
f
s
e
r
v
i
c
e
pr
o
v
i
d
e
d
b
y
N
o
r
t
h
e
r
n
En
g
i
n
e
e
r
i
n
g
S
e
r
v
i
c
e
s
,
I
n
c
.
an
d
a
r
e
n
o
t
t
o
b
e
u
s
e
d
f
o
r
an
y
t
y
p
e
o
f
c
o
n
s
t
r
u
c
t
i
o
n
un
l
e
s
s
s
i
g
n
e
d
a
n
d
s
e
a
l
e
d
by
a
P
r
o
f
e
s
s
i
o
n
a
l
En
g
i
n
e
e
r
i
n
t
h
e
e
m
p
l
o
y
o
f
No
r
t
h
e
r
n
E
n
g
i
n
e
e
r
i
n
g
Se
r
v
i
c
e
s
,
I
n
c
.
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
of 25
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
KEYMAP
M
A
S
O
N
S
T
.
HIBDON CT.
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 14, 2024 FOR
ADDITIONAL INFORMATION.
2.REFER TO THE MASON STREET INFRASTRUCTURE DRAINAGE REPORT FOR
ADDITIONAL INFORMATION.
A
LEGEND:
EMERGENCY OVERFLOW PATH
C2 C100 Q2
(cfs)
Q100
(cfs)