Loading...
HomeMy WebLinkAboutENCLAVE AT REDWOOD - FDP220014 - SUBMITTAL DOCUMENTS - ROUND 7 - Street Related DocumentRevisions: STATE OF COLORADO DateByDescriptionNo. DRAWN BY: SCALE: CHECKED BY: JOB NO.: DATE: DESIGNED BY: SHEET NO.: CO N C E P T U A L B R I D G E A B U T M E N T EN C L A V E A T R E D W O O D - P E D B R I D G E FO R T C O L L I N S , C O DH I C O M M U N I T I E S AMN AMN AMN 03/8/2024 AS SHOWN 240396 CONCEPT CONCRETE ABUTMENT BOTTOM CHORD FLOOR BEAM BRIDGE ELEVATION 35' TOP CHORD DIAGONALVERTICAL 1/30/2024 DYOB DATE: CHECKED: DRAWN: DYOB DESIGNED: APPROVED: PROJECT NUMBER: \\ Q U I K R E T E . N E T \ C O N T E C H \ C O M M O N \ E N G I N E E R I N G \ D Y O \ D Y O B \ 2 2 2 7 6 9 \ B R I D G E 2 2 2 7 6 9 . D W G 1/ 3 0 / 2 0 2 4 5 : 4 1 P M SHEET NO.: OF 222769 4 The graphic information and details contained in these plans is schematic in nature. The plans, elevations and sections have been developed automatically in a way that demonstrates your current input in a relative and proportional manner. The details included in these plans have been selected to represent commonly built construction assemblies. These are not Engineering drawings, and as such, the details may vary in the final design for your project depending on many variables that are selected in your final scope of work and specifications.PRELIMINARY NOT FOR CONSTRUCTION 1 CONTECH DRAWING DYOB® 800-338-1122 513-645-7000 513-645-7993 FAX 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 REVISION DESCRIPTIONDATEMARK BY RCONTINENTAL BRIDGE Connector® 35' Span x 10' Width Enclave at Redwood Pedestrian Bridge Fort Collins, Colorado The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. www.contechES.com BRIDGE SUMMARY Connector Pedestrian Bridge 35' Span x 10' Width Deck Type: Concrete Bridge Finish: Weathering Steel BRACE DIAGONAL BOTTOM CHORD CONCRETE DECK FLOOR BEAM DECK BRACING FRAMING SIDE DAM BRIDGE PLAN 10 ' 1/30/2024 DYOB DATE: CHECKED: DRAWN: DYOB DESIGNED: APPROVED: PROJECT NUMBER: \\ Q U I K R E T E . N E T \ C O N T E C H \ C O M M O N \ E N G I N E E R I N G \ D Y O \ D Y O B \ 2 2 2 7 6 9 \ B R I D G E 2 2 2 7 6 9 . D W G 1/ 3 0 / 2 0 2 4 5 : 4 1 P M SHEET NO.: OF 222769 4 The graphic information and details contained in these plans is schematic in nature. The plans, elevations and sections have been developed automatically in a way that demonstrates your current input in a relative and proportional manner. The details included in these plans have been selected to represent commonly built construction assemblies. These are not Engineering drawings, and as such, the details may vary in the final design for your project depending on many variables that are selected in your final scope of work and specifications.PRELIMINARY NOT FOR CONSTRUCTION 2 CONTECH DRAWING DYOB® 800-338-1122 513-645-7000 513-645-7993 FAX 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 REVISION DESCRIPTIONDATEMARK BY RCONTINENTAL BRIDGE Connector® 35' Span x 10' Width Enclave at Redwood Pedestrian Bridge Fort Collins, Colorado The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. www.contechES.com SECTION 10'TOP CHORD CONCRETE DECK (BY OTHERS) DIAGONAL BRACE DIAGONAL VERTICAL BOTTOM CHORD SAFETY PICKET RUB RAIL TOE PLATE 54 " ( M i n ) 1/30/2024 DYOB DATE: CHECKED: DRAWN: DYOB DESIGNED: APPROVED: PROJECT NUMBER: \\ Q U I K R E T E . N E T \ C O N T E C H \ C O M M O N \ E N G I N E E R I N G \ D Y O \ D Y O B \ 2 2 2 7 6 9 \ B R I D G E 2 2 2 7 6 9 . D W G 1/ 3 0 / 2 0 2 4 5 : 4 1 P M SHEET NO.: OF 222769 4 The graphic information and details contained in these plans is schematic in nature. The plans, elevations and sections have been developed automatically in a way that demonstrates your current input in a relative and proportional manner. The details included in these plans have been selected to represent commonly built construction assemblies. These are not Engineering drawings, and as such, the details may vary in the final design for your project depending on many variables that are selected in your final scope of work and specifications.PRELIMINARY NOT FOR CONSTRUCTION 3 CONTECH DRAWING DYOB® 800-338-1122 513-645-7000 513-645-7993 FAX 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 REVISION DESCRIPTIONDATEMARK BY RCONTINENTAL BRIDGE Connector® 35' Span x 10' Width Enclave at Redwood Pedestrian Bridge Fort Collins, Colorado The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. www.contechES.com BEARING SIDE VIEW INFORMATION PROVIDED FOR REPRESENTATION ONLY. ACTUAL BEARING DIAGRAMS TO BE BASED ON FINAL DESIGN. CONCRETE ABUTMENT SETTING PLATE BASE PLATE BOTTOM CHORD END FLOOR BEAM END VERTICAL CONCRETE DECK ANCHOR RODS 1 4" RUB RAIL DETAIL ∠ 11 4 x 11 4 x 18 x 5" LG W/(2) Ø1 4" x 112" LG ZINC PLATED CARRIAGE BOLTS AT EACH VERTICAL CONT 5 4" x 6" NOM IRON WOODS® CLEAR ALL HEART RUB RAIL S4S LATERAL REINFORCING FORM DECK CONCRETE DECK (BY OTHERS) LONGITUDINAL REINFORCING MI N . CO V E R VA R I E S FLOOR BEAM CONCRETE DECK REINFORCING LAP LAP FLO O R B E A M FORM DECK DETAIL GALVANIZED FORM DECK 1/30/2024 DYOB DATE: CHECKED: DRAWN: DYOB DESIGNED: APPROVED: PROJECT NUMBER: \\ Q U I K R E T E . N E T \ C O N T E C H \ C O M M O N \ E N G I N E E R I N G \ D Y O \ D Y O B \ 2 2 2 7 6 9 \ B R I D G E 2 2 2 7 6 9 . D W G 1/ 3 0 / 2 0 2 4 5 : 4 1 P M SHEET NO.: OF 222769 4 The graphic information and details contained in these plans is schematic in nature. The plans, elevations and sections have been developed automatically in a way that demonstrates your current input in a relative and proportional manner. The details included in these plans have been selected to represent commonly built construction assemblies. These are not Engineering drawings, and as such, the details may vary in the final design for your project depending on many variables that are selected in your final scope of work and specifications.PRELIMINARY NOT FOR CONSTRUCTION 4 CONTECH DRAWING DYOB® 800-338-1122 513-645-7000 513-645-7993 FAX 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 REVISION DESCRIPTIONDATEMARK BY RCONTINENTAL BRIDGE Connector® 35' Span x 10' Width Enclave at Redwood Pedestrian Bridge Fort Collins, Colorado The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use. If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others. www.contechES.com