HomeMy WebLinkAboutFISCHER PROPERTIES - FDP230010 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATIONSYMBOL MANUFACTURER/MODEL/DESCRIPTION
RAIN BIRD XCZ-100-PRB-COM
WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL
APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1"
PRESSURE REGULATING 40PSI QUICK-CHECK BASKET
FILTER. 0.3 GPM-20 GPM
PIPE TRANSITION POINT IN DRIP BOX
PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP
TUBING WITH RISER IN 6" (150MM) DRIP BOX.
DRIP FLUSH VALVE
3/4" PVC BALL VALVE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC
REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH
NPT THREADED INLET/OUTLET, FOR
COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY.
QUICK COUPLER ASSEMBLY
RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY.
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL
PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE
AS MAINLINE PIPE.
MASTER VALVE ASSEMBLY
BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER
VALVE THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO
MATCH POC
REDUCED PRESSURE BACKFLOW PREVENTER
FEBCO 825YA: SIZED TO MATCH POC METER SIZE. REDUCED
PRESSURE BACKFLOW PREVENTER IN STRONG BOX
SBBC-30AL: LOW PROFILE BACKFLOW ENCLOSURE, WITH
MARINE GRADE ALUMINUM. 30"L, 30"H, 16.25"W (76.2CM L,
76.2CM H, 41.275CM W).
PEDESTAL MOUNT TRADITIONAL
HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER
CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL.
INSTALL WIRELESS RAIN SENSOR AND SOLAR SYNC WITH
CENTRALUS WIFI ENABLED CARTRIDGE
CREATIVE SENSOR TECHNOLOGY FSI-T
1" PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM
MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER
ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL
OUTPUT. FLOW RANGE: .86-52 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL
TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED
ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.
IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION
LATERAL LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE
PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER
CHART.
IRRIGATION LATERAL LINE: NATIVE PLANTING DRIP
IRRIGATION LATERAL LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE
PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING
MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR
SHRUBS PER ADJACENT EMITTER CHART
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
1.25-INCH UNLESS OTHERWISE NOTED
PIPE SLEEVE: PVC SCHEDULE 40
INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE
PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE
BUNDLES SHALL SHARE THE SAME SLEEVE.
A
SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 8` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 10` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 12` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 15` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 17` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER MP1000 PROS-06-PRS40-CV
TURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSURE
REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40
BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210
TO 270 ARC, O=OLIVE 360 ARC.
40
HUNTER MP2000 PROS-06-PRS40-CV
TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC
90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC.
40
HUNTER MP3000 PROS-06-PRS40-CV
TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC
90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC.
40
HUNTER MP3500 PROS-06-PRS40-CV
TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN
ADJUSTABLE ARC, 90-210.
40
HUNTER RZWS-18-CV
18IN. LONG RZWS WITH INSTALLED NO BUBBLER. INSTALL
WITH CHECK VALVE, 1/2IN. SWING JOINT FOR CONNECTION
TO 1/2IN. PIPE. INSTALL WITH RAINBIRD XB-05PC EMITTER
PER DETAILS.
30
IRRIGATION SCHEDULE INSTALLATION GENERAL NOTES
1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION
SYSTEM (NOT OBTAINED) OF APPROX. 80 PSI, AT A MAXIMUM PEAK FLOW OF 10 GPM AT
THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR
TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE
IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE.
2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE
POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK
SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.
3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE
INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP.
4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR
CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION.
4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND
BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE
VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS.
4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS
PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF
EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM,
ETC.
5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND
PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR
GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF
THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED
DESIGN, DETAILS, OR SPECIFICATIONS.
7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE
INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION
COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY.
8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND
ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION
OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO
SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL
SPRINKLERS MAY BE REQUIRED.
8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE
AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE
ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN
WITHIN THE 3'-5' RANGE NOTED ABOVE.
9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.
10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA
CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE
REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION
DESIGNER FOR APPROVAL.
11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO
CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL
BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH
PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE
INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES
BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE
HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR.
12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF
UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED
PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE
SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.
13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG
IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND
MAY NOT BE THE LARGEST SIZE ON PLANS.
16.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE
ROUTED WITH MAINLINE.
16.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS
17.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR
TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS
ARE IRRIGATED ON DRIP SYSTEM.
18.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
19.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT
UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND
ESTABLISHMENT.
20.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES,
AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION.
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A
NOTES:
1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS.
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DEDICATED IRRIGATION WATER TAP AND
METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL
PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION
UNIT, MASTER VALVE, AND FLOW SENSOR ASSEMBLY AS
INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO
CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY
WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL
LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE.
CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE.
IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL
IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY
IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE
SLEEVED.
MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN
SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL
INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN
SEPARATE SLEEVES.
1
2
3
4
REFERENCE NOTES SCHEDULE
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
1
.
0
Pr
i
n
t
e
d
O
n
:
2/
7
/
2
0
2
4
9
:
3
5
A
M
Fi
l
e
N
a
m
e
:
IR
-
F
I
S
C
H
E
R
P
R
O
P
E
R
T
Y
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
3 FDP 02/07/2024
IRRIGATION LEGEND
AND NOTES
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.0
NORTH
0 10 20 40
SCALE: 1"=20'-0"
8" SS
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRRCONTROL
IRRCONTROL
IRRCONTROL
IRR
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
OH
U
OH
U
OH
U
OHU OHU
E
6" ABD
N
W
8" SS 8" SS 8" SS
8"
S
S
8"
S
S
8"
S
S
8"
S
S
8"
S
S
8"
S
S
8"
S
S
6" ABDN W
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
8"
A
B
D
N
S
S
E
E
E
E
E
E
6"
A
B
D
N
W
6"
A
B
D
N
W
6"
A
B
D
N
W
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
6" ABDN W
6"
A
B
D
N
W
6"
A
B
D
N
W
6"
A
B
D
N
W
6"
A
B
D
N
W
6"
A
B
D
N
W
6"
A
B
D
N
W
FO FO FO
S
8" W 8" W 8" W
8" W
8" W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
6"
W
H Y D
6" W 6" W 6" W
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
W W W W W W W W W W W W W W W W
UD
UD
UD
UD
UD
SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
S
SSS
S S S
S
SS
G G G G G G G G G G G
G
G
G
G G G G G G G G G G G G
G
G
G
G
G G
G
GGG
G G
W
W
W
W
W
W
(3)3"
DRIVE
DE
L
M
A
R
S
T
R
E
E
T
(3)3"(3)3"
(3)3"(3)3"
(3)3"
(3)3"
(2)2"
(2)2"
3
3
3
(2)2"
(2)2"
A27
91"
A28
41"
A29
81"
A30
81"
A31
81"
A32
41"
A33
81"
A34
101"
A35
61"
A36
91"
A37
51"
A38
61"
A43
-1"
A44
-1"
A39
91"
A40
81"
A51
101"
A52
101"
A53
71"
A54
111"
A55
61"
A56
91"
A41
101"
A42
101"
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
1
.
1
Pr
i
n
t
e
d
O
n
:
2/
7
/
2
0
2
4
9
:
3
5
A
M
Fi
l
e
N
a
m
e
:
IR
-
F
I
S
C
H
E
R
P
R
O
P
E
R
T
Y
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
3 FDP 02/07/2024
IRRIGATION PLAN
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.1
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
1
.
2
D
D
D
D
D
ST
S SS SS
15
"
S
S
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
S
T
S
T
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
15
"
S
S
ST
ST
G
G
G
G
G
G
G
G
G
G
G
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
E
E
E
E
E E E
6" ABD
N
W
6" ABD
N
W
6" ABD
N
W
6" ABD
N
W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
6" ABDN W 6" ABDN W
W
W
E
E W
E
E
E
E
E E E E E E
G
G
G
G
G
G G G G G G G G G G G G G
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E E E E E E E E E E E E
E
E E
E
E
E
WC S
W
D
D
FO
FO
FO FO
FO
FO
8" ABDN SS 8" ABDN SS 8" ABDN SS 8" ABDN SS 8" ABDN SS
8" W
8" W
8" W
8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W
SS
SS
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W
W
W
W
SS
SS
UD
UD
UD UD UD UD UD UD UD UD
SS
SS
SS
SS
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
GAS
W
G G G G G G
W
W
W
W
W
NYLO
P
L
A
S
T
DO NO
T
P
O
L
L
U
T
E
DRAIN
S
T
O
WATE
R
W
A
Y
S
DO NO
T
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPL
A
S
T
D
U
C
T
I
L
E
I
R
O
N
NYLO
P
L
A
S
T
DO NO
T
P
O
L
L
U
T
E
DRA
I
N
S
T
O
WATE
R
W
A
Y
S
DO NOT
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOPL
A
S
T
D
U
C
T
I
L
E
I
R
O
N
SS
SS
SS
DS
DS
DS
DS
DS
DS
DS DS
DS
DS
DS DS
DS
DS
DS
DS
DS DS
DS DS DS DS
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DS
DS
DS
DS
DS
DS
NYL
O
P
L
A
S
T
DO N
O
T
P
O
L
L
U
T
E
DRAIN
S
T
O
WATE
R
W
A
Y
S
DO NO
T
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOP
L
A
S
T
D
U
C
T
I
L
E
I
R
O
N
W
SS
SS
SS
W
W
F
S
M
POC NO.2
TAP & METER SIZE: 3/4-INCH
PEAK DEMAND: 10 GPM
AVAILABLE PRESSURE: APPROX. 80 PSI
CONTROLLER 'B'
120 VAC POWER REQUIRED
1
2
(2)2"
4
CONTRACTOR SHALL COORDINATE
MAINLINE AND VALVE
INSTALLATION IN TREE LAWN AREA
WITH GENERAL CONTRACTOR TO
AVOID CONCRETE PAN
(2)2"
(2)2"(2)2"(2)2"
(2)2"
A3
101"
A4
101"
A5
101"
A6
101"
A7
101"
A8
91"
A9
81"
A10
101"
A11
101"
A12
101"
A13
91"
A14
91"
A15
101"
A16
51"
A17
101"
A18
91"
A19
101"
A20
91"
A21
101"
A22
91"
A23
101"
A24
101"A25
91"
A26
81"
A45
-1"
A46
-1"
A47
51"
A48
-1"
A49
-1"
A50
-1"
A
A1
111"
A2
91"
CONTROL WIRES INSTALLED IN
ELECTRICAL CONDUIT
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
1
.
2
Pr
i
n
t
e
d
O
n
:
2/
7
/
2
0
2
4
9
:
3
5
A
M
Fi
l
e
N
a
m
e
:
IR
-
F
I
S
C
H
E
R
P
R
O
P
E
R
T
Y
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
3 FDP 02/07/2024
IRRIGATION PLAN
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.2
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
I
R
1
.
1
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
2
.
1
Pr
i
n
t
e
d
O
n
:
2/
7
/
2
0
2
4
9
:
3
5
A
M
Fi
l
e
N
a
m
e
:
IR
-
F
I
S
C
H
E
R
P
R
O
P
E
R
T
Y
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
3 FDP 02/07/2024
IRRIGATION DETAILS
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR2.1
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MASTER VALVE
ASSEMBLY2 ISOLATION GATE VALVE
ASSEMBLY4
QUICK COUPLING VALVE
ASSEMBLY5 REMOTE CONTROL TURF
VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN
ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY
SPRINKLER ASSEMBLY8
FLOW SENSOR
ASSEMBLY3BACKFLOW PREVENTION
UNIT1
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
2
.
2
Pr
i
n
t
e
d
O
n
:
2/
7
/
2
0
2
4
9
:
3
5
A
M
Fi
l
e
N
a
m
e
:
IR
-
F
I
S
C
H
E
R
P
R
O
P
E
R
T
Y
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
3 FDP 02/07/2024
IRRIGATION DETAILS
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR2.2
NORTH
0 10 20 40
SCALE: 1"=20'-0"
REMOTE CONTROL DRIP
VALVE ASSEMBLY9 SINGLE OUTLET EMITTER
ASSEMBLY10
TYPICAL TRENCHING
DETAIL16
DRIP FLUSH CAP
ASSEMBLY12
TYPICAL SLEEVING
DETAIL15
24" min.
INLINE DRIP PIPE ASSEMBLY
FOR TREES IN NATIVE 11
PEDESTAL MOUNT CONTROLLER
ASSEMBLY14
A
ROOT WATERING
BUBBLER ASSEMBLY13
18" ROOT ZONE WATERING
SYSTEM PER PLAN (1 OF X)
PER PLAN
FINISH GRADE
LATERAL PIPE - SIZE PER PLANROOT BALL
NOTES
INSTALL RZWS SLEEVE OVER TUBE TO HELP
PREVENT SOIL INTRUSION
REFER TO LANDSCAPE PLAN FOR
TREE PLANTING DETAIL