HomeMy WebLinkAboutFISCHER PROPERTIES - FDP230010 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATIONSYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-100-PRB-COM WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM PIPE TRANSITION POINT IN DRIP BOX PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP TUBING WITH RISER IN 6" (150MM) DRIP BOX. DRIP FLUSH VALVE 3/4" PVC BALL VALVE SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY. QUICK COUPLER ASSEMBLY RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH CORROSION-RESISTANT STAINLESS STEEL SPRING, THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY. ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. MASTER VALVE ASSEMBLY BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO MATCH POC REDUCED PRESSURE BACKFLOW PREVENTER FEBCO 825YA: SIZED TO MATCH POC METER SIZE. REDUCED PRESSURE BACKFLOW PREVENTER IN STRONG BOX SBBC-30AL: LOW PROFILE BACKFLOW ENCLOSURE, WITH MARINE GRADE ALUMINUM. 30"L, 30"H, 16.25"W (76.2CM L, 76.2CM H, 41.275CM W). PEDESTAL MOUNT TRADITIONAL HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INSTALL WIRELESS RAIN SENSOR AND SOLAR SYNC WITH CENTRALUS WIFI ENABLED CARTRIDGE CREATIVE SENSOR TECHNOLOGY FSI-T 1" PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT. FLOW RANGE: .86-52 GPM. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. IRRIGATION LATERAL LINE: NATIVE PLANTING DRIP IRRIGATION LATERAL LINE: 3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR SHRUBS PER ADJACENT EMITTER CHART IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED PIPE SLEEVE: PVC SCHEDULE 40 INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL SHARE THE SAME SLEEVE. A SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 8` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 10` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 12` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 15` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 17` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER MP1000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. 40 HUNTER MP2000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. 40 HUNTER MP3000 PROS-06-PRS40-CV TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. 40 HUNTER MP3500 PROS-06-PRS40-CV TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210. 40 HUNTER RZWS-18-CV 18IN. LONG RZWS WITH INSTALLED NO BUBBLER. INSTALL WITH CHECK VALVE, 1/2IN. SWING JOINT FOR CONNECTION TO 1/2IN. PIPE. INSTALL WITH RAINBIRD XB-05PC EMITTER PER DETAILS. 30 IRRIGATION SCHEDULE INSTALLATION GENERAL NOTES 1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION SYSTEM (NOT OBTAINED) OF APPROX. 80 PSI, AT A MAXIMUM PEAK FLOW OF 10 GPM AT THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL SPRINKLERS MAY BE REQUIRED. 8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN WITHIN THE 3'-5' RANGE NOTED ABOVE. 9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 16.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 16.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS 17.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 18.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 19.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 20.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. SYMBOL DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE DEDICATED IRRIGATION WATER TAP AND METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT, MASTER VALVE, AND FLOW SENSOR ASSEMBLY AS INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW SHALL BE TESTED UPON INSTALLATION AND ANNUALLY THEREAFTER. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE. IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE SLEEVED. MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN SEPARATE SLEEVES. 1 2 3 4 REFERENCE NOTES SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 0 Pr i n t e d O n : 2/ 7 / 2 0 2 4 9 : 3 5 A M Fi l e N a m e : IR - F I S C H E R P R O P E R T Y . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Sam Coutts, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 Erik Fischer 125 S. Howes St. Suite 900 Fort Collins, CO 80521 p. 970.372.6396 ENGINEER ARCHITECT LAND PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Danny Weber 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970.221.6789 VFLA ARCHITECTURE + INTERIORS Jeff Fleischer 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 1 FDP 03/15/23 2 FDP 09/06/23 3 FDP 02/07/2024 IRRIGATION LEGEND AND NOTES DESIGN DEVELOPMENT FISCHER PROPERTIES FORT COLLINS, CO TEAM MLP R16-057.1 IR1.0 NORTH 0 10 20 40 SCALE: 1"=20'-0" 8" SS CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRR OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OH U OH U OH U OHU OHU E 6" ABD N W 8" SS 8" SS 8" SS 8" S S 8" S S 8" S S 8" S S 8" S S 8" S S 8" S S 6" ABDN W 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S 8" A B D N S S E E E E E E 6" A B D N W 6" A B D N W 6" A B D N W G G G G G G G G G G G G G G G G G 6" ABDN W 6" A B D N W 6" A B D N W 6" A B D N W 6" A B D N W 6" A B D N W 6" A B D N W FO FO FO S 8" W 8" W 8" W 8" W 8" W SS SS SS SS SS SS SS SS SS SS 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W H Y D 6" W 6" W 6" W / / / / / / / / / / / / / / / / / / / / / / / / W W W W W W W W W W W W W W W W UD UD UD UD UD SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS S S SSS S S S S SS G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G GGG G G W W W W W W (3)3" DRIVE DE L M A R S T R E E T (3)3"(3)3" (3)3"(3)3" (3)3" (3)3" (2)2" (2)2" 3 3 3 (2)2" (2)2" A27 91" A28 41" A29 81" A30 81" A31 81" A32 41" A33 81" A34 101" A35 61" A36 91" A37 51" A38 61" A43 -1" A44 -1" A39 91" A40 81" A51 101" A52 101" A53 71" A54 111" A55 61" A56 91" A41 101" A42 101" DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 1 Pr i n t e d O n : 2/ 7 / 2 0 2 4 9 : 3 5 A M Fi l e N a m e : IR - F I S C H E R P R O P E R T Y . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Sam Coutts, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 Erik Fischer 125 S. Howes St. Suite 900 Fort Collins, CO 80521 p. 970.372.6396 ENGINEER ARCHITECT LAND PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Danny Weber 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970.221.6789 VFLA ARCHITECTURE + INTERIORS Jeff Fleischer 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 1 FDP 03/15/23 2 FDP 09/06/23 3 FDP 02/07/2024 IRRIGATION PLAN DESIGN DEVELOPMENT FISCHER PROPERTIES FORT COLLINS, CO TEAM MLP R16-057.1 IR1.1 NORTH 0 10 20 40 SCALE: 1"=20'-0" MA T C H L I N E - S E E S H E E T I R 1 . 2 D D D D D ST S SS SS 15 " S S ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST S T S T 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S 15 " S S ST ST G G G G G G G G G G G E E E E E E E E E E E E E E E OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E E E E E 6" ABD N W 6" ABD N W 6" ABD N W 6" ABD N W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W 6" ABDN W W W W W W W W W W W W W W W W W W W W W W W W W 6" ABDN W 6" ABDN W W W E E W E E E E E E E E E E G G G G G G G G G G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E WC S W D D FO FO FO FO FO FO 8" ABDN SS 8" ABDN SS 8" ABDN SS 8" ABDN SS 8" ABDN SS 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W SS SS G G G G G G G G G G G G G G G G W W W W SS SS UD UD UD UD UD UD UD UD UD UD SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS GAS W G G G G G G W W W W W NYLO P L A S T DO NO T P O L L U T E DRAIN S T O WATE R W A Y S DO NO T P O L L U T E D R A I N S T O W A T E R W A Y S NYLOPL A S T D U C T I L E I R O N NYLO P L A S T DO NO T P O L L U T E DRA I N S T O WATE R W A Y S DO NOT P O L L U T E D R A I N S T O W A T E R W A Y S NYLOPL A S T D U C T I L E I R O N SS SS SS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS NYL O P L A S T DO N O T P O L L U T E DRAIN S T O WATE R W A Y S DO NO T P O L L U T E D R A I N S T O W A T E R W A Y S NYLOP L A S T D U C T I L E I R O N W SS SS SS W W F S M POC NO.2 TAP & METER SIZE: 3/4-INCH PEAK DEMAND: 10 GPM AVAILABLE PRESSURE: APPROX. 80 PSI CONTROLLER 'B' 120 VAC POWER REQUIRED 1 2 (2)2" 4 CONTRACTOR SHALL COORDINATE MAINLINE AND VALVE INSTALLATION IN TREE LAWN AREA WITH GENERAL CONTRACTOR TO AVOID CONCRETE PAN (2)2" (2)2"(2)2"(2)2" (2)2" A3 101" A4 101" A5 101" A6 101" A7 101" A8 91" A9 81" A10 101" A11 101" A12 101" A13 91" A14 91" A15 101" A16 51" A17 101" A18 91" A19 101" A20 91" A21 101" A22 91" A23 101" A24 101"A25 91" A26 81" A45 -1" A46 -1" A47 51" A48 -1" A49 -1" A50 -1" A A1 111" A2 91" CONTROL WIRES INSTALLED IN ELECTRICAL CONDUIT DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 1 . 2 Pr i n t e d O n : 2/ 7 / 2 0 2 4 9 : 3 5 A M Fi l e N a m e : IR - F I S C H E R P R O P E R T Y . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Sam Coutts, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 Erik Fischer 125 S. Howes St. Suite 900 Fort Collins, CO 80521 p. 970.372.6396 ENGINEER ARCHITECT LAND PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Danny Weber 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970.221.6789 VFLA ARCHITECTURE + INTERIORS Jeff Fleischer 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 1 FDP 03/15/23 2 FDP 09/06/23 3 FDP 02/07/2024 IRRIGATION PLAN DESIGN DEVELOPMENT FISCHER PROPERTIES FORT COLLINS, CO TEAM MLP R16-057.1 IR1.2 NORTH 0 10 20 40 SCALE: 1"=20'-0" MA T C H L I N E - S E E S H E E T I R 1 . 1 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 2 . 1 Pr i n t e d O n : 2/ 7 / 2 0 2 4 9 : 3 5 A M Fi l e N a m e : IR - F I S C H E R P R O P E R T Y . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Sam Coutts, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 Erik Fischer 125 S. Howes St. Suite 900 Fort Collins, CO 80521 p. 970.372.6396 ENGINEER ARCHITECT LAND PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Danny Weber 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970.221.6789 VFLA ARCHITECTURE + INTERIORS Jeff Fleischer 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 1 FDP 03/15/23 2 FDP 09/06/23 3 FDP 02/07/2024 IRRIGATION DETAILS DESIGN DEVELOPMENT FISCHER PROPERTIES FORT COLLINS, CO TEAM MLP R16-057.1 IR2.1 NORTH 0 10 20 40 SCALE: 1"=20'-0" MASTER VALVE ASSEMBLY2 ISOLATION GATE VALVE ASSEMBLY4 QUICK COUPLING VALVE ASSEMBLY5 REMOTE CONTROL TURF VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY SPRINKLER ASSEMBLY8 FLOW SENSOR ASSEMBLY3BACKFLOW PREVENTION UNIT1 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR 2 . 2 Pr i n t e d O n : 2/ 7 / 2 0 2 4 9 : 3 5 A M Fi l e N a m e : IR - F I S C H E R P R O P E R T Y . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Sam Coutts, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 Erik Fischer 125 S. Howes St. Suite 900 Fort Collins, CO 80521 p. 970.372.6396 ENGINEER ARCHITECT LAND PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Danny Weber 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970.221.6789 VFLA ARCHITECTURE + INTERIORS Jeff Fleischer 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 1 FDP 03/15/23 2 FDP 09/06/23 3 FDP 02/07/2024 IRRIGATION DETAILS DESIGN DEVELOPMENT FISCHER PROPERTIES FORT COLLINS, CO TEAM MLP R16-057.1 IR2.2 NORTH 0 10 20 40 SCALE: 1"=20'-0" REMOTE CONTROL DRIP VALVE ASSEMBLY9 SINGLE OUTLET EMITTER ASSEMBLY10 TYPICAL TRENCHING DETAIL16 DRIP FLUSH CAP ASSEMBLY12 TYPICAL SLEEVING DETAIL15 24" min. INLINE DRIP PIPE ASSEMBLY FOR TREES IN NATIVE 11 PEDESTAL MOUNT CONTROLLER ASSEMBLY14 A ROOT WATERING BUBBLER ASSEMBLY13 18" ROOT ZONE WATERING SYSTEM PER PLAN (1 OF X) PER PLAN FINISH GRADE LATERAL PIPE - SIZE PER PLANROOT BALL NOTES INSTALL RZWS SLEEVE OVER TUBE TO HELP PREVENT SOIL INTRUSION REFER TO LANDSCAPE PLAN FOR TREE PLANTING DETAIL