Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTHE LANDING AT LEMAY MULTIFAMILY AND MIXED-USE - FDP230020 - SUBMITTAL DOCUMENTS - ROUND 3 - RESPONSE TO STAFF REVIEW COMMENTS (5)LE
M
A
Y
A
V
E
N
U
E
D
U
F
F
D
R
I
V
E
LI
N
K
L
A
N
E
MULBERRY STREET
VINE DRIVE
CO
R
D
O
V
A
R
O
A
D
LINCOLN AVENUE
Lane
Bike
(min.)
Walk
84' ROW (min.)
52' Roadway
7'
Walk
(min.)
(min.)
Pkwy.
10'
Pkwy.
6'
(min.)
10'
Util.
Esmt.
15'
Esmt.
Util.
15'
Center
10'
Travel
11'
Travel
11'
3'
Lane
Bike
7'3'
Bike
Lane
Buffer
6'
Bike
Lane
Buffer
2-LANE ARTERIAL
(CORDOVA ROAD)
SHEET INDEXPROJECT INFORMATION
N
S
EW
FINAL UTILITY PLANS FOR
THE LANDING AT LEMAY
A TRACT OF LAND LOCATED IN THE NORTHWEST QUARTER OF SECTION 7, TOWNSHIP 7 NORTH, RANGE 68 WEST
OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
VICINITY MAP
SCALE: 1" = 1000'
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
Original Field Survery:
Nothern Engineering
Project No. 1791-003
Date: July 7, 2022
Additional Field Survey:
Northern Engineering
Project No. 1791-003
Date: November 4, 2022
PLANNER/LANDSCAPE ARCHITECT
OWNER/APPLICANT
SITE ENGINEER
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
SITE SURVEYOR
Kumar and Associates, Inc.
Geotechnical Engineering Study and Pavement Thickness Design
Proposed Watermark Apartments at Lemay
Fort Collins, Colorado
Project No. 22-3-168
Date: July 29, 2022
* This list is provided as a courtesy reference only. Avant Civil Group assumes no responsibility for the accuracy
or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all
utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado
(UNCC) at 811 for additional information.
Ripley Design, Inc.
Russ Lee, PLA
419 Canyon Avenue, Suite 200
Fort Collins, CO. 80521
(970) 224-5828
Thompson Thrift Residential
111 Monument Circle, Suite 1500
Indianapolis, IN. 46204
(800) 687-0012
I hereby affirm that these final construction plans were prepared under
my direct supervision, in accordance with all applicable City of Fort
Collins and State of Colorado standards and statutes, respectively; and
that I am fully responsible for the accuracy of all design. revisions, and
record conditions that I have noted on these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's below.
before you dig.Call
R
City of Fort Collins, CO
UTILITY PLAN APPROVAL
APPROVED:
CITY ENGINEER,APPROVED SHEETS DATE
APPROVED:
WATER & WASTEWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
STORMWATER UTILITY,APPROVED SHEETS DATE
APPROVED:
PARK PLANNING & DEVELOPMENT,APPROVED SHEETS DATE
APPROVED:
TRAFFIC OPERATIONS,APPROVED SHEETS DATE
APPROVED:
ENVIRONMENTAL PLANNER,APPROVED SHEETS DATE
Project Datum: NAVD88
Benchmark 12-07: South side of Vine Dr. on the south headwall of the bridge over Dry Creek basin 0.4
miles east of North Lemay Ave.
Elevation: 4947.86
Benchmark 8-02: On the southeast corner of the intersection of Lemay Avenue and Mulberry Street, in
the curb, on the southeast side of a triangular island that contains the traffic signal.
Elevation: 4939.27
Please Note: This plan set is using NAVD88 for a Vertical Datum. Surrounding developments have
used NGVD29 unadjusted datum (prior city of Fort Collins datum) for their vertical datums.
If NGVD29 unadjusted datum (prior city of Fort Collins datum) is required for any purpose, the following
equation should be used: NGVD29 unadjusted datum (prior city of Fort Collins datum) = NAVD88 -
3.18'.
Basis of Bearings
The Basis of Bearings is the North line of Section 7-T7N-R68W as bearing North 88° 53' 46" East. The
Northwest and Northeast Corners of said section being #6 rebar with 3 1
4" aluminum caps, both stamped
with PLS 17497.
SITE
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
Delich Associates
Matt Delich, PE
2272 Glen Haven Drive
Loveland, CO 80538-4903
(970) 669-2061
Avant Civil Group, LLC
Danny Weber, PE
1337 Riverside Ave, Unit 2
Fort Collins, Colorado 80524
(970)305-3534
UTILITY CONTACT LIST
SERVICE COMPANY CONTACT PHONE
GAS
ELECTRIC
CABLE
CONNEXION
TELECOM
WATER
WASTEWATER
STORMWATER
XCEL ENERGY
CITY OF FORT COLLINS LIGHT & POWER
COMCAST
FORT COLLINS CONNEXION
CENTURYLINK
EAST LARIMER COUNTY WATER DISTRICT
BOXELDER SANITATION DISTRICT
CITY OF FORT COLLINS UTILITIES
AL ERMER
CODY SNOWDON
MARCUS PETTY
JOHN STARK
WILLIAM JOHNSON
RANDY SIDDENS
BRIAN ZICK
WES LAMARQUE
(970) 225-7869
(970) 416-5306
(720) 275-0572
(970) 207-7890
(970) 377-6401
(970) 493-2044
(970) 498-0604
(970) 416-2418
PROJECT TEAM PROJECT BENCHMARKS
FIELD SURVEY
SUBSURFACE EXPLORATION
SITE SURVEYOR
TYPICAL SECTIONS
CO
V
E
R
S
H
E
E
T
1
N/A
N/A
C 001
C 001 1 COVER SHEET
GENERAL NOTES
C 100 2 GENERAL & CONSTRUCTION NOTES
C 101 3 GENERAL & CONSTRUCTION NOTES
EXISTING CONDITIONS AND DEMOLITION
C 200 4 EXISTING CONDITIONS & DEMOLITION PLAN
C 201 5 EXISTING CONDITIONS & DEMOLITION PLAN
EROSION CONTROL
C 300 6 EROSION CONTROL NOTES
C 301 7 INITIAL EROSION CONTROL PLAN
C 302 8 INTERIM EROSION CONTROL PLAN
C 303 9 ULTIMATE EROSION CONTROL PLAN
C 304 10 EROSION CONTROL DETAILS
SITE
C 400 11 OVERALL PAVING PLAN
C 401 12 PAVING PLAN
C 402 13 PAVING PLAN
C 403 14 PAVING PLAN
C 404 15 PAVING PLAN
C 410 16 ADA ROUTING PLAN
GRADING
C 500 17 OVERALL GRADING PLAN
C 501 18 GRADING PLAN
C 502 19 GRADING PLAN
C 503 20 GRADING PLAN
C 504 21 GRADING PLAN
C 505 22 GRADING PLAN
C 506 23 GRADING PLAN
C 507 24 GRADING PLAN
C 508 25 GRADING PLAN
C 509 26 GRADING PLAN
C 510 27 SUBGRADE PLAN
STREETS
C 510 28 CORDOVA ROAD PLAN & PROFILE
C 511 29 CORDOVA ROAD PLAN & PROFILE
C 512 30 CORDOVA ROAD CROSS-SECTIONS
C 513 31 CORDOVA ROAD STRIPING PLAN
C 514 32 INTERSECTION DETAILS
UTILITIES
C 600 33 OVERALL UTILITY PLAN
C 601 34 UTILITY PLAN
C 602 35 UTILITY PLAN
C 603 36 UTILITY PLAN
C 604 37 UTILITY PLAN
C 605 38 DRY UTILITY PLAN
C 610 39 SANITARY SEWER A PLAN & PROFILE
C 611 40 SANITARY SEWER A PLAN & PROFILE
C 612 41 SANITARY SEWER A, A5, & A7 PLAN & PROFILE
C 613 42 SANITARY SEWER B PLAN & PROFILE
C 614 43 SANITARY SEWER B, B1, & B3 PLAN & PROFILE
C 615 44 SANITARY SEWER B2 & B2-1 PLAN & PROFILE
C 620 45 WATER LINE 1 PLAN & PROFILE
C 621 46 WATER LINE 1 PLAN & PROFILE
C 622 47 WATER LINE 2 PLAN & PROFILE
C 623 48 WATER LINE 2 PLAN & PROFILE
C 624 49 WATER LINE 3 PLAN & PROFILE
C 625 50 WATER LINE 4 PLAN & PROFILE
C 630 51 STORM DRAIN 1, 2, 4, & 7 PLAN & PROFILE
C 631 52 STORM DRAIN 3 PLAN & PROFILE
C 632 53 STORM DRAIN 3-2, 3-3, & 5-2 PLAN & PROFILE
C 633 54 STORM DRAIN 5 PLAN & PROFILE
C 634 55 STORM DRAIN 6 & 6-2 PLAN & PROFILE
DRAINAGE
C 701 56 DEVELOPED DRAINAGE EXHIBIT
DETAILS
C 800 57 SANITARY SEWER DETAILS
C 801 58 WATERLINE DETAILS
C 802 59 WATERLINE DETAILS
C 803 60 STORM DRAIN DETAILS
C 804 61 STORM DRAIN DETAILS
C 805 62 STORM DRAIN DETAILS
C 806 63 STORM DRAIN DETAILS
C 807 64 STORM DRAIN DETAILS
C 808 65 STREET DETAILS
C 809 66 STREET DETAILS
C 810 67 PRIVATE SITE DETAILS
C 811 68 PRIVATE SITE DETAILS
NOVEMBER 2023
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
A. GENERAL NOTES
1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County
Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any
applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of
these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown
in these plans.
4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of
said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not
relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold
harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from
any errors and omissions contained in these plans.
5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications
current at the date of approval of the plans by the City of Fort Collins Engineer.
6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the
Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer
shall be responsible for unknown underground utilities.
7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or
grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the
respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the
Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility
crossings required.
9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to
modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a
timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any
disruption of any utility service as well as the utility companies.
11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification
shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be
required prior to commencement of any work.
12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer
should be constructed prior to installation of the water lines and dry utilities.
13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility.
14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a
storm sewer, channel, irrigation ditch or any waters of the United States.
15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health,
Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and
approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release
of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least
two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement.
18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether
resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins
failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19.All recommendations of the Final Drainage Report, dated November 15, 2023 by Avant Civil Group shall be followed and implemented.
20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in
good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be
removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City
of Fort Collins street inspector.
22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is
obtained, if applicable.
23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer
shall notify the the City of Fort Collins Engineering Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins -
221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort
Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer
absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation.
24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete
and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the
original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort
Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed
Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt.
Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report.
25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all
intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of
Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the
City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the
purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property
lines and marked so as to reduce the excavation necessary for building connections.
27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads
within these districts.
28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild
Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29.Prior to the commencement of any construction, the contractor shall contact the City of Fort Collins Forester to schedule a site inspection for any tree
removal requiring a permit.
30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to
OSHA Publication 2226, Excavating and Trenching.
31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort
Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be
responsible for providing any and all traffic control devices as may be required by the construction activities.
32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic
Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then
the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local
street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the
Development.
34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction
activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins.
35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings,
or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification,
and annotate the dimension on the as-built record drawings.
37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and
a copy of any permits and extension agreements needed for the job.
38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the
Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to The City of
Fort Collins Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer.
40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the
basis of bearings. The information shall be as follows:
Project Datum: NAVD88
Benchmark 12-07: South side of Vine Dr. on the south headwall of the bridge over Dry Creek basin 0.4 miles east of North Lemay Ave.
Elevation: 4947.86
Benchmark 8-02: On the southeast corner of the intersection of Lemay Avenue and Mulberry Street, in the curb, on the southeast side of a triangular island
that contains the traffic signal.
Elevation: 4939.27
Please Note: This plan set is using NAVD88 for a Vertical Datum. Surrounding developments have used NGVD29 unadjusted datum (prior city of Fort
Collins datum) for their vertical datums.
If NGVD29 unadjusted datum (prior city of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 unadjusted
datum (prior city of Fort Collins datum) = NAVD88 - 3.18'.
Basis of Bearings
The Basis of Bearings is the North line of Section 7-T7N-R68W as bearing North 88° 53' 46" East. The Northwest and Northeast Corners of said section
being #6 rebar with 3 1
4" aluminum caps, both stamped with PLS 17497.
41.All stationing is based on centerline of roadways unless otherwise noted.
42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping,
structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the
Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the
first Certificate of Occupancy.
43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the
City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an
asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required.
The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer and/or the City of Fort Collins Inspector at the time the
cuts are made.
44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to
the grades and condition as required by these plans.
45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship
defects for a minimum period of two years from the date of acceptance.
47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and
pipes, for the following private streets: (PRIVATE STREET NAMES T.B.D.)
48.Approved Variances are listed as follows: N/A
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other
required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule,
construction plans, and erosion control report.
4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently
watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown
herein.
5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s)
required for immediate construction operations, and for the shortest practical period of time.
6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by
ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project
street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control
(e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City.
7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to
ensure the continued performance of their intended function.
b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from
all drainage infrastructure and other public facilities.
9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way,
and make sure streets and walkways are cleaned at the end of each working day.
10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their
release into any waters of the United States.
11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and
perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before
turning the maintenance over to the City or Homeowners Association (HOA).
13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or
contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil
and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and
disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located
at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be
removed and properly disposed of prior to the area being restored.
15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever
measures are determined necessary, as directed by the City.
16.A Vehicle Tracking Control Pad shall be installed whenever it is necessary for construction equipment including but not limited to personal vehicles exiting
existing roadways. No earthen materials, i.e., stone, dirt, etc., shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpile(s),
staging area(s), construction material(s), concrete washout area(s) and/or building site(s).
17.For additional information see separate Stormwater Management Plan / Erosion Control Report for The Landing at Lemay.
B. Street Improvement Notes
1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to
any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted
for approval prior to placement of any asphalt.
3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a
clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel
cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has
been inspected and approved by the City of Fort Collins Engineer.
5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not
allowed.
6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25,
Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be
made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new
asphalt overlay work.
7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the
Right-of-Way Work Permit traffic control plan.
8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters
that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth
section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire
subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at
least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of
the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked,
replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the
"proof roll." All "proof rolls" shall be preformed in the presence of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes
listed here.
2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5.All lane lines shall be latex paint.
6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the
same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8.Latex paint applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10.All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during
the field inspection must be corrected before the 2-year warranty period will begin.
12.The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13.Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins
Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen
condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of
the 2-year warranty period for new construction (except fair wear on traffic markings).
15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
16.Contractor is responsible for removing all anchors, posts, signs and/or delineators in Construction area. Contractor may keep the signs, or call the City
Traffic Division to have them removed.
17.No “Reset” anchors, posts, signs, and/or delineators will be accepted.
18.All anchors, posts, signs, and/or delineators shall be new and be consistent with the LCUASS criteria.
D. Storm Drainage Notes
1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite
drainage facilities shall be the responsibility of the property owner(s).
2.All recommendations of the Final Drainage Report, dated November 15, 2023 by Avant Civil Group shall be followed and implemented.
3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and
approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release
of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least
two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement.
4.See City of Fort Collins Stormwater Criteria Manual – Appendix F Construction Control Measures Standard Notes and Standard Erosion Control Notes.GE
N
E
R
A
L
&
C
O
N
S
T
R
U
C
T
I
O
N
N
O
T
E
S
2
N/A
N/A
C 100
NOTES BY THOMPSON THRIFT
CONTRACTOR TO PROVIDE ASBUILTS IN ACCORDANCE
WITH THE CITY OF FORT COLLINS REQUIREMENTS FOR
UTILITIES, SITE CERTIFICATION, AND LOT CERTIFICATIONS.
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
F. BOXELDER SANITATION DISTRICT GENERAL NOTES
1.Existing Utility Locates: It shall be the responsibility of the Contractor to coordinate field locates of all existing utilities prior to commencement of any construction.
Contractor shall also notify all affected utility companies prior to commencing construction. In the event of damage to any existing utility, the contractor shall
immediately notify the owner of the utility involved and unless authorized in writing by the owner of the subject utility, shall not attempt to make repairs. The cost of
repairs shall be the responsibility of the Contractor.
2.District Owned Easement Pictures: Contractor to provide sequential digital pictures spaced at no more than 300 feet detailing conditions of the off-site Boxelder
Owned Easement Conditions and any structures that could be affected, to the District and the property owner prior to the start of any off-site work. These pictures
shall include all existing fence, ditches, ditch structures, out buildings, water troughs, trees and all other landscaping. Pictures are to be placed at no more than
four (4) pictures on a 11x8 sheet of photo paper inserted into transparent sleeves and delivered with the drawings of record in a three (3) ring binder.
3.Protection of Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done.
4.Safety: All sewer main installation within the District shall be subject to current (Occupational Safety and Heath Association (OSHA) and the Colorado Safety
Association, (CSA) safety requirements. Contractor shall also comply with any and all requirements and regulations as set forth by City, County, State and Federal
agencies having applicable authority.
5.Start of Construction: No construction shall begin without prior design review of the District. The District shall be notified 48 hours in advance of starting
construction or testing to allow for scheduling.
6.Road Excavation Permits: In event that State, County or City road excavation permit(s) are required, the Contractor is responsible for obtaining all road permits
which may be required.
7.Other Permits: The Contractor shall be responsible for obtaining all permits required for construction.
8.Revisions: No verbal authorization for field revision shall be given. All requests for field revision shall be made in writing accompanied by proposed change
indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on the Drawings of Record.
9.Materials: Plastic Pipe -All gravity sanitary sewer piping shall be Polyvinyl Chloride (PVC) unless otherwise noted on the approved drawings. Pipe 15” and smaller
shall conform to ASTM D3034, Type PSM, and SDR 35. Pipe 18” and larger shall conform to ASTM F679. All fittings shall be (PVC) unless otherwise noted.
10.Pipe Cover: A minimum cover of 3-1/2 feet of cover shall be maintained throughout the sewer line and service line installation.
11.Bedding: All sewer main installation shall include bedding. Bedding shall be ¾” washed rock uniformly graded and compacted. Refer to force main desgin for force
main bedding requirements. Trench shall be excavated to a depth below established grade equal to ¼ of pipe diameter (min. 4”). Bell depressions shall be
provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2” uniformly graded washed rock shall be used for
stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Place bedding in such a manner as to provide solid, uniform
bearing surface for full length of barrel. Minimum 30” initial lift above pipe before other than hand compaction equipment is to be used. Note maximum trench width
detail.
12.Backfill: Backfilling of trench shall be performed as soon as practical, subsequent to inspection and approval. Backfilling of acceptable material shall not be placed
in lifts of greater than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway and residential areas and 90% in all off-site easement areas
unless otherwise noted. Compaction testing of bedding and back fill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance
with the requirements of the applicable authority or as required in project specific specifications.
13.Concrete: All concrete construction shall be completed utilizing 3,000 psi at twenty-eight (28) days or equal concrete.
14.Pavement or Other Repairs: In event that asphalt or concrete pavement, sidewalks, storm sewers, waterline or any other public or privately owned property is
damaged or requires reconstruction due to the work, repairs or replacement will be made in accordance with the requirements of the appropriate governing
authority. Private property will be returned to its original condition or as close to original condition as reasonably possible, unless otherwise noted on the drawings.
15.Service Taps on Existing Lines: All taps made on existing lines shall be completed at developer's expense by District personnel or the District's authorized
contractor with no exception.
16.Inspection: Construction shall conform to District Standards and Specifications or project specific specifications at all times. The District shall inspect the
construction as necessary and shall observe all line testing. The District shall have the authority to ascertain that all construction of facilities is equal to or better
than minimum construction requirements as set forth in
17.Testing: All lines shall be pressure tested and flushed by the Contractor in accordance with District Standards and Specifications and under the District's
supervision. Upon passing, copies of all passing test results including soils compaction in the area of sewer main construction shall be provided to the District.
18.Acceptance: Upon completion of all utility construction (sewer and other) and fulfillment of all District requirements, preliminary acceptance of new sewer system
improvements will occur in accordance with District's acceptance procedure.
19.Warranty: The Contractor shall warrant the materials, installation, workmanship and surface restoration for a period of two years from date of preliminary
acceptance. During this warranty period the Developer shall promptly repair any defects in the work and maintain the work area. At the close of the two-year
warranty period the District will make a field inspection. Upon satisfactory correction of any deficiencies noted the District would make final acceptance of the lines
and work. The lines and the appurtenances shall then become the sole property and responsibility of Boxelder Sanitation District.
20.Drawings of Record and Total Costs: Within 90 days of preliminary acceptance of the new facilities, the District shall be provided with acceptable Drawings of
Record of the complete system consisting of two sets of fill size reproduced prints, two sets of ½-size reproduced prints, one set of 6 mil double matted
reproducible mylars and one complete digital file equivalent (software and version to be confirmed at time of delivery). Written confirmation of the total cost of all
sewer system improvements shall also be submitted with the Drawings of Record.
E. EAST LARIMER COUNTY WATER DISTRICT
GENERAL NOTES FOR CONSTRUCTION
Version: 12/2/2021
The following information is condensed from the current "Standard Construction Specifications for Water Mains" (Specification) as
adopted by the East Larimer County Water District (‘ELCO’ or ‘District’) and is to be considered as such. In the event of any
conflict the full District Specification document shall take precedence over these general notes.
1.Standards and Specifications: Construction shall be per the District Specifications in effect at the start of construction. Material
or equipment shall be manufactured per the most recent version of applicable industry standards.
2.Locates: Contractor shall coordinate field locates of all existing utilities prior to commencement of any construction and as
required notify all affected utility companies prior to commencing construction. Cost of repairs to any utility damaged during
District waterline installation shall be the responsibility of the Contractor.
3.Damage to Property: Contractor shall continuously maintain adequate protection from damage of all public and private
property through which the work is done and shall be fully responsible for all costs associated with damage to any and all
public and private property.
4.Safety: Contractor shall comply with any and all requirements and regulations as set forth by any local, City, County, State or
Federal agency having applicable authority.
5.Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs, trees or other plantings) that has a mature
height of over 3 feet (3-ft) shall be placed within ten feet (10-ft) of any District waterline or appurtenance (distribution main,
service line, fire hydrant, meter, etc.). Bushes or shrubs with a mature height of less than 3-ft shall be placed a minimum 5-ft
from any District water line, service line or appurtenance. The District shall have the right to remove any landscaping that
violates this standard, at any time such landscaping is discovered, and shall not be required to replace the removed
landscaping.
6.Design Approval and Construction Start: No construction shall begin without prior design acceptance from ELCO. District shall
be notified 48 hours in advance of starting construction or testing to allow for scheduling.
7.Permits: Contractor is responsible for obtaining all permits which may be required. For any permitting where the District must
apply for a permit the Contractor shall coordinate, cover the cost and schedule the permit acquisition with the District.
8.Changes During Construction: No verbal authorization for field revision shall be All requests for such field revision shall be
made in writing with the proposed change indicated on a copy of the signed design drawings. Any field revision approved and
installed shall also be accurately documented on the As-Built Drawings.
9.Materials of Construction:
a.Pipe: All water line piping shall be Polyvinyl Chloride (PVC), DR 18 (pressure class 235 psi) and manufactured in
accordance with AWWA Standard C900-16, "Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fitting, 4-inch through
60-inch, ", or most recent version.
b.Tracer Wire: All water piping shall be installed with a twelve (12) gauge solid copper wire, plastic coated, six hundred (600)
volts, taped to top of pipe and surfaced at each hydrant into a tracer wire box.
c.Pipe Joints: Pipe joints shall be made using an integral bell with an elastomeric gasket push-on type joint or using machined
couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint.
d.Materials and Installation: All materials installed shall be new and free of manufacturer defects or damage.
e.Pipe Fittings: All fittings shall be ductile iron mechanical joint and manufactured in accordance with AWWA Standard C153,
250 psi rating. Fittings shall be furnished with fusion bonded epoxy exterior coating and interior lining. All fitting connections
to valves, fire hydrants or other MJ type connections shall use foster adaptor type connectors.
f.Gate Valves: Gate valves shall conform to AWWA Standard C509 with mechanical joint, 2" open left operating nut and
resilient seat.
g.Butterfly Valves: Butterfly valves shall be used for all valves 12-inches and larger and conform to AWWA Standard C504
with mechanical joint, 2" open left operating nut with resilient seat.
h.Fire Hydrants: Hydrants shall conform to AWWA Standard C502, 1" square open-right operating nut with epoxy coated
shoe.
i.Pipe, Valve and Fitting Wrap: All ductile iron fittings, valves, fire hydrant shoes and plugs shall be poly-wrapped with 8-mil
thick polyethylene plastic wrap, double layered, and ends securely taped prior to backfill. All fitting bolts shall be
fluoropolymer coated (‘blue bolt’ type) with zinc caps installed.
10.Bedding: All pipe shall be bedded in 3/4" washed rock uniformly graded and compacted. Trench shall be excavated to a depth
below established grade equal to 1/4 of pipe diameter (min. 4"). 1-1/2" uniformly graded washed rock shall be used for
stabilization where needed. Bedding material shall be placed and compacted under and around sides of the pipe per the pipe
manufacturer’s installation recommendations.
11.Backfill: Backfill of acceptable material shall be placed in ‘lifts’ of uniform horizontal layers not to exceed 6-inches of
compacted depth per lift. Minimum 18" of compacted backfill above pipe must be in place before rolling mechanical
equipment type compaction is to be used. Backfill shall be compacted to 95% of optimum density in roadway areas or per
road authority’s requirements, and 90% in fields or non-road locations. Backfill compaction testing frequency shall be at least
one test per 100-lineal feet of pipeline length and at varying depths and locations in accordance with the requirements of the
applicable road authority or beginning 1.5-feet above top of pipe and at 1-foot increments to grade.
12.Joint Restraint: All fittings, tees, plugs and fire hydrants shall be provided with foster adaptor type and/or other mechanical
joint restraint in accordance with District Specifications or as required per engineer’s design. Thrust blocks shall be used only
as required per field conditions and as approved or directed by the District field inspector.
13.Concrete: All concrete construction, including thrust blocks, shall be completed utilizing Type 5 or equal cement only.
14.Asphalt Replacement: For asphalt pavement that is cut and has been in place less than two years (according to City or
County Engineer's record), the cut shall be a minimum of 20 feet in width and will be replaced to the specified depth by a
paving machine.
15.Pipe Cover: Pipe cover of 4-1/2 to 5-1/2 feet over top of pipe shall be maintained throughout the waterline and service line
installation, particularly in areas of new grading and drainage swales. Maximum allowable cover shall be 6 feet, unless
specifically approved by the District.
16.Connection to Existing System: All connections to existing waterlines shall be completed at the developer's expense.
17.Inspection: The District shall have the authority to assign an inspector who shall inspect, check and verify that any and all
work, including all materials to be incorporated in the work, excavation, bedding, backfill, testing and all construction methods
and practices of the installed facilities is equal to or better than minimum construction requirements as set forth in the District’s
Specifications.
18.Testing: All lines shall be pressure tested, chlorinated and flushed by the Contractor in accordance with District Specifications
and under the District's supervision. Upon passing chlorination testing, bacteriological testing will be completed by a State
certified water quality control laboratory. Copies of all passing test results, including soils compaction in the area of water
main construction, shall be provided to the District.
19.Preliminary Acceptance: Preliminary Acceptance shall be issued to the Owner when all project work is complete, tested and
operational such that the infrastructure is ready to be accepted by the District. Documentation required prior to issuance of
Preliminary Acceptance includes but is not limited to bacteriological test report, flushing report, hydrotest report, compaction
testing reports with map of test locations, statement of water line installation costs, As-built drawings and Record Drawings.
Following receipt, review and acceptance by the District of these and other documents as may be required per project
specifics, the District will issue Preliminary Acceptance.
20.Project As-Built and Record Drawing Requirements:
a.As-Built Drawings are compiled and maintained during construction by the Contractor and identify, in red ink, on-site
changes to the original design. As-Built Drawings shall be delivered to the District (electronically in PDF format or otherwise
as requested by the District) for acceptance and to the project’s design engineer for creation of Record Drawings.
b.Record Drawings are prepared by the project’s design engineer and shall accurately reflect any change made in the
field which varies from the accepted construction plans, as noted in the As-Built Drawings, including at a minimum, field
dimensions and elevations, horizontal and vertical locations of underground utilities and appurtenances. The Contractor’s
surveyor shall survey in all fittings, valves, water service curb stops and other appurtenances so as to accurately document
and create a final set of Record Drawings with water line, fitting and appurtenance locations that accurately represents the
final, installed infrastructure. The Record Drawings shall be reviewed and accepted by the District prior to Preliminary
Acceptance of the project. Record Drawings are to be delivered to the District in electronic format as Adobe (PDF), AutoCAD
and ArcView shape files (release version to be confirmed with District at time of submittal).
21.Warranty: The Owner/Developer shall warrant all work associated with the waterline installation including, but not limited to
the materials, installation workmanship and surface restoration for a period of two (2) years from date of Preliminary
Acceptance. During this warranty period the Owner/Developer shall repair any defects in the work and maintain the work
area. At the close of the two-year warranty period and upon satisfactory correction of any deficiencies noted, the District shall
accept the constructed lines and appurtenances as the sole property and responsibility of the District.
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
GE
N
E
R
A
L
&
C
O
N
S
T
R
U
C
T
I
O
N
N
O
T
E
S
3
N/A
N/A
C 101
EAS
T
V
I
N
E
D
R
I
V
E
BUR
L
I
N
G
T
O
N
N
O
R
T
H
E
R
N
R
A
I
L
R
O
A
D
DRY
C
R
E
E
K
AIRPARK INDUSTRIAL
B MB M
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E
E
E
E
E
E
E
E
EXISTING
ELECTRIC
EXISTING TREES
TO REMAIN (TYP.)
EXISTING
STREET
LIGHT (TYP.)
N
O
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
EXISTING
FENCE
CITY OF FORT COLLINS
KEYMAP
NOT TO SCALE
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
EXISTING ELECTRIC E
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
SUBSURFACE EXPLORATION BY:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6.LIMITS OF STREET REPAIR ARE APPROXIMATE. FINAL LIMITS TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR AT THE TIME THE STREET CUTS
ARE MADE. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STANDARDS.
7.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
8.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
EXISTING OVERHEAD UTILITY OHE
ORIGINAL FIELD SURVERY:
NOTHERN ENGINEERING
PROJECT NO. 1791-003
DATE: JULY 7, 2022
ADDITIONAL FIELD SURVEY:
NORTHERN ENGINEERING
PROJECT NO. 1791-003
DATE: NOVEMBER 4, 2022
KUMAR AND ASSOCIATES, INC.
FORT COLLINS, COLORADO
PROJECT NO. 22-3-168
DATE: JULY, 29, 2022
LEGEND
FIELD SURVEY
NOTES
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET 5
5
4
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
&
D
E
M
O
L
I
T
I
O
N
P
L
A
N
4
1" = 50'
N/A
C 200
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
NORTH LIN
K
L
A
N
E
S
HYD
TEST
STAH2O
VAUL
T
ELEC
H Y D
TEST
STA
AR V
H2O
V.P.
ST
HYD
W
VAUL
T
ELEC
ELEC
ELEC
S
F.O.
W
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
XX
SS
SS
SS
X
X
X
X
X
12
"
W
12" W
E
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
E
8" W
W
G
G E
E
E
G G
12" W
EFO
12" W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W
24
"
W
STST
ST
SS
EXISTING TREE
TO REMAIN (TYP.)
EXISTING TREES TO
BE REMOVED (TYP.)
EXISTING
STRIPING (TYP.)
EXISTING 24"
WATER
(NWCWD)
EXISTING
STORM DRAIN
EXISTING
STORM DRAIN
EXISTING
ELECTRIC
EXISTING
STREET
LIGHT (TYP.)
EXISTING 8" WATER
(ELCO)
EXISTING
WATER METER
EXISTING MANHOLE TO REMAIN
ADJUST RIM ELEVATION
EXISTING FIRE
HYDRANT
TO REMAIN
EXISTING
GAS LINE
EXISTING SANITARY
MANHOLE (TYP.)
EXISTING 8"
SANITARY SEWER
(BOXELDER)
EXISTING LOT LINE
TO BE VACATED
BY THIS PLAT
EXISTING LOT LINE
TO BE VACATED
BY THIS PLAT
EXISTING LOT LINE
TO BE VACATED
BY THIS PLAT
EXISTING LOT LINE
TO BE VACATED
BY THIS PLAT
EXISTING BARRICADE
TO BE REMOVED
76
'
R
O
W
EXISTING
12" WATER
(ELCO)
PROPOSED
SAWCUT
EXISTING 30" VERTICAL
CURB & GUTTER
CO
R
D
O
V
A
RO
A
D
EXISTING 8"
SANITARY SEWER
(BOXELDER)
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
EXISTING 5' WALK
EXISTING
12" WATER
(ELCO)
EXISTING
8" WATER
(ELCO)
EXISTING VEGETATION
BOUNDARY
±66' LF VERTICAL CURB & GUTTER
TO BE REMOVED
EXISTING ASPHALT AND
CONCRETE TO BE REMOVED
BEGIN
STRIPING REMOVAL
END
STRIPING REMOVAL
EXISTING ASPHALT AND
CONCRETE TO BE REMOVED
UTILITY TRENCH
STREET PATCH
UTILITY TRENCH
STREET PATCH
PROPOSED
SAWCUT
PROPOSED
SAWCUTEXISTING FIRE HYDRANT
TO REMAIN
EXISTING FENCE
TO REMAIN
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
EXISTING ELECTRIC E
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
SUBSURFACE EXPLORATION BY:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6.LIMITS OF STREET REPAIR ARE APPROXIMATE. FINAL LIMITS TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR AT THE TIME THE STREET CUTS
ARE MADE. ALL REPAIRS TO BE DONE IN ACCORDANCE WITH CITY STANDARDS.
7.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
8.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
EXISTING OVERHEAD UTILITY OHE
ORIGINAL FIELD SURVERY:
NOTHERN ENGINEERING
PROJECT NO. 1791-003
DATE: JULY 7, 2022
ADDITIONAL FIELD SURVEY:
NORTHERN ENGINEERING
PROJECT NO. 1791-003
DATE: NOVEMBER 4, 2022
KUMAR AND ASSOCIATES, INC.
FORT COLLINS, COLORADO
PROJECT NO. 22-3-168
DATE: JULY, 29, 2022
LEGEND
FIELD SURVEY
NOTES
MATCH LINE - SEE SHEET 4
5
4
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
&
D
E
M
O
L
I
T
I
O
N
P
L
A
N
5
1" = 50'
N/A
C 201
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
STANDARD EROSION CONTROL NOTES (CITY OF FORT COLLINS)
GENERAL EROSION CONTROL REQUIREMENTS
THESE NOTES ARE A SUMMARY FOR THE LEGAL REQUIREMENTS, THAT ARE SET FORTH IN THE FORT COLLINS STORMWATER
CRITERIA MANUAL (FCSCM), AND THAT ANY CONFLICT IS RESOLVED BY THE MORE STRINGENT REQUIREMENT CONTROLLING.
1.THE PROPERTY OWNER, OWNER’S REPRESENTATIVE, DEVELOPER, DESIGN ENGINEER, GENERAL CONTRACTOR, SUB-CONTRACTORS, OR
SIMILAR TITLE FOR THE DEVELOPING ENTITY (HERE AFTER REFERRED TO AS THE DEVELOPER) HAS PROVIDED THESE EROSION CONTROL
MATERIALS IN ACCORDANCE WITH EROSION CONTROL CRITERIA SET FORTH IN THE MANUAL AS AN ATTEMPT TO IDENTIFY EROSION,
SEDIMENT, AND OTHER POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH THESE CONSTRUCTION ACTIVITIES AND PREVENTING THOSE
POLLUTANTS FROM LEAVING THE PROJECT SITE AS AN ILLICIT DISCHARGE. FULL CITY REQUIREMENTS AND ARE OUTLINED AND CLARIFIED IN
THE MANUAL UNDER CHAPTER 4: CONSTRUCTION CONTROL MEASURES AND SHOULD BE USED TO IDENTIFY AND DEFINE WHAT IS NEEDED
ON A PROJECT.
2.THE DEVELOPER SHALL MAKE THEMSELVES THOROUGHLY FAMILIAR WITH THE PROVISIONS AND THE CONTENT OF THE SPECIFICATIONS
LAID OUT IN THE MANUAL, THE DEVELOPMENT AGREEMENT, THE EROSION CONTROL MATERIALS COMPILED FOR THIS PROJECT, AND THE
FOLLOWING NOTES AS ALL THESE MATERIALS ARE APPLICABLE TO THIS PROJECT.
3.THE DEVELOPER SHALL IMPLEMENT AND MAINTAIN CONTROL MEASURES FOR ALL POTENTIAL POLLUTANTS FROM THE START OF LAND
DISTURBING ACTIVITIES UNTIL FINAL STABILIZATION OF THE CONSTRUCTION SITE.
4.THE CITY EROSION CONTROL INSPECTOR SHALL BE NOTIFIED AT LEAST TWENTY-FOUR (24) HOURS PRIOR TO THE DESIRED START OF ANY
CONSTRUCTION ACTIVITIES ON THIS SITE TO ALLOW ADEQUATE TIME FOR ON-SITE CONFIRMATION (INITIAL INSPECTION WHICH CAN TAKE UP
TO TWO BUSINESS DAYS AFTER RECEIVING THE REQUEST) THAT THE SITE IS IN FACT PROTECTED FROM SEDIMENT AND POLLUTANTS
DISCHARGES OFF SITE. PLEASE CONTACT EROSION@FCGOV.COM EARLY TO SCHEDULE THOSE INITIAL EROSION CONTROL INSPECTIONS
WELL IN ADVANCE SO THAT DEMOLITION, CLEARING, GRUBBING, TREE REMOVAL, AND SCRAPING MAY BEGIN WITHOUT DELAY. FAILURE TO
RECEIVE AN ON-SITE CONFIRMATION BEFORE CONSTRUCTION ACTIVITIES COMMENCE IS AN AUTOMATIC “NOTICE OF VIOLATION” AND CAN
RESULT IN FURTHER ENFORCEMENT ACTIONS.
5.THE DEVELOPER SHALL PROACTIVELY PROVIDE ALL APPROPRIATE CONTROL MEASURES TO PREVENT DAMAGE TO ADJACENT
DOWNSTREAM AND LEEWARD PROPERTIES. THIS INCLUDES BUT IS NOT LIMITED TO: TREES, SHRUBS, LAWNS, WALKS, PAVEMENTS,
ROADWAYS, STRUCTURES, CREEKS, WETLANDS, STREAMS, RIVERS, AND UTILITIES THAT ARE NOT DESIGNED FOR REMOVAL, RELOCATION,
OR REPLACEMENT IN THE COURSE OF CONSTRUCTION.
6.AT ALL TIMES THE DEVELOPER SHALL BE RESPONSIBLE TO ENSURE ADEQUATE CONTROL MEASURES ARE DESIGNED, SELECTED,
INSTALLED, MAINTAIN, REPAIRED, REPLACED, AND ULTIMATELY REMOVED IN ORDER TO PREVENT AND CONTROL EROSION SUSPENSION,
SEDIMENT TRANSPORTATION, AND POLLUTANT DISCHARGE AS A RESULT OF CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS PROJECT.
7.ALL APPLICABLE CONTROL MEASURES BASED UPON THE SEQUENCING AND/OR PHASING OF THE PROJECT SHALL BE INSTALLED PRIOR TO
THOSE CONSTRUCTION ACTIVITIES COMMENCING.
8.AS DYNAMIC CONDITIONS (DUE TO THE NATURE, TIMING, SEQUENCE, AND PHASING OF CONSTRUCTION) IN THE FIELD MAY WARRANT
CONTROL MEASURES IN ADDITION, OR DIFFERENT, TO WHAT IS SHOWN ON THESE PLANS, THE DEVELOPER SHALL AT ALL TIMES BE
RESPONSIBLE TO IMPLEMENT THE CONTROL MEASURES THAT ARE MOST EFFECTIVE WITH THE CURRENT STATE AND PROGRESS OF
CONSTRUCTION. THE DEVELOPER SHALL IMPLEMENT WHATEVER MEASURES ARE DETERMINED NECESSARY, AND/OR AS DIRECTED BY THE
CITY EROSION CONTROL INSPECTOR. THE DEVELOPER SHALL INSURE THAT ALL EROSION CONTROL PLANS (MAPS) OR SWMP DOCUMENTS
ARE UPDATED TO REFLECT THE CURRENT SITE CONDITIONS, WITH UPDATES BEING INITIALED AND DATED. THESE SITE INSPECTIONS AND
SITE CONDITION UPDATES SHALL BE MADE AVAILABLE UPON REQUEST BY THE CITY.
9.ALL LISTINGS, PROVISIONS, MATERIALS, PROCEDURES, ACTIVITIES, SITE WORK AND THE LIKE ARTICULATED IN THIS OR OTHER WRITTEN
SITE-SPECIFIC DOCUMENTS (INCLUDING BUT NOT LIMITED TO THE EROSION CONTROL REPORTS, DEVELOPMENT AGREEMENTS,
LANDSCAPE, AND DRAINAGE MATERIALS) SHALL MEET OR EXCEED THE MOST RESTRICTIVE LANGUAGE FOR CITY, COUNTY, STATE, AND
FEDERAL REGULATIONS WITH REGARDS TO EROSION, SEDIMENT, POLLUTANT, AND OTHER POLLUTION SOURCE CONTROL MEASURES. THE
DEVELOPER SHALL BE RESPONSIBLE TO COMPLY WITH ALL OF THESE AFOREMENTIONED LAWS AND REGULATIONS.
10.THE DEVELOPER SHALL ENSURE THAT ALL APPROPRIATE PERMITS (CDPS GENERAL PERMIT STORMWATER DISCHARGES ASSOCIATED WITH
CONSTRUCTION ACTIVITY, DEWATERING, CLEAN WATER ACT, ARMY CORPS OF ENGINEERS’ 404 WETLANDS MITIGATION PERMIT, ETC.) HAVE
BEEN ATTAINED PRIOR TO THE RELEVANT ACTIVITY HAS BEGUN. THESE PERMITS OR COPIES SHALL BE MADE AVAILABLE UPON REQUEST BY
THE CITY.
11.THE DEVELOPER SHALL FURNISH ALL CONVENIENCES AND ASSISTANCES TO AID THE EROSION CONTROL INSPECTORS OF MATERIALS,
WORKMANSHIP, RECORDS, AND SELF-INSPECTIONS, ETC. OF THE CONTROL MEASURES INVOLVED IN THE CONSTRUCTION ACTIVITIES.
12.THE DEVELOPER SHALL REQUEST CLARIFICATION OF ALL APPARENT SITE CONSTRUCTION ISSUES THAT MAY ARISE DUE TO
INCONSISTENCIES IN CONSTRUCTION PLANS FOR THE SITE OR SITE CONDITIONS AROUND THE SELECTED CONTROL MEASURES BY
CONTACTING THE EROSION CONTROL INSPECTOR. THE EROSION CONTROL INSPECTOR WILL NOT BE RESPONSIBLE FOR ANY
EXPLANATIONS, INTERPRETATIONS, OR SUPPLEMENTARY DATA PROVIDED BY OTHERS.
13.ALL CONTROL MEASURES SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUAL.
14.THE CITY RESERVES THE RIGHT TO REQUIRE ADDITIONAL CONTROL MEASURES AS SITE CONDITIONS WARRANT, TO THE EXTENT
AUTHORIZED BY RELEVANT LEGAL AUTHORITY.
15.AS WITH ANY CONSTRUCTION STANDARDS, OCCASIONS MAY ARISE WHERE THE MINIMUM EROSION CONTROL STANDARDS ARE EITHER
INAPPROPRIATE OR CANNOT BE JUSTIFIED. IN THESE CASES, A VARIANCE TO THESE STANDARDS MAY BE APPLIED FOR PURSUANT TO THE
TERMS, CONDITIONS, AND PROCEDURES OF THE MANUAL.
16.INSPECTION. THE CONTRACTOR SHALL INSPECT SITE POLLUTANT SOURCES AND IMPLEMENT CONTROL MEASURES AT A MINIMUM OF ONCE
EVERY TWO WEEKS DURING CONSTRUCTION AND WITHIN 24 HOURS FOLLOWING A PRECIPITATION EVENT. DOCUMENTATION OF EACH
INSPECTION SHALL BE RECORDED AND RETAINED BY THE CONTRACTOR.
17.ALL TEMPORARY CONTROL MEASURES SHALL BE CLEANED, REPAIRED, OR RECONSTRUCTED AS NECESSARY IN ORDER TO ASSURE
CONTINUAL PERFORMANCE OF THEIR INTENDED FUNCTION. ALL RETAINED SEDIMENTS, PARTICULARLY THOSE ON PAVED ROADWAY
SURFACES, SHALL BE REMOVED AND DISPOSED OF IN A MANNER AND LOCATION SO AS NOT TO CAUSE THEIR RELEASE INTO ANY DRAINAGE
WAY.
18.ANY CONTROL MEASURE MAY BE SUBSTITUTED FOR ANOTHER STANDARD CONTROL MEASURE SO LONG AS THAT CONTROL MEASURE IS
EQUAL TO, OR OF GREATER PROTECTION THAN THE ORIGINAL CONTROL MEASURE THAT WAS TO BE USED IN THAT LOCATION. (EX. SILT
FENCE, FOR WATTLES, OR FOR COMPACT BERMS) WATTLE ALONE ON COMMERCIAL CONSTRUCTION SITES HAVE SHOWN TO BE AN
INEFFECTIVE SUBSTITUTE FOR SILT FENCE OR COMPACT BERMS UNLESS IT IS ACCOMPANIED BY A CONSTRUCTION FENCE TO PREVENT
VEHICLE TRAFFIC.
19.ANY IMPLEMENTATION OR REPLACEMENT OF EXISTING CONTROL MEASURES FOR A NON-STANDARD CONTROL, OR ALTERNATIVE CONTROL
MEASURE, SHALL REQUIRE THE REVIEW AND ACCEPTANCE BY THE CITY EROSION CONTROL STAFF BEFORE THE MEASURE WILL BE
ALLOWED TO BE USED ON THIS PROJECT. THESE CONTROL MEASURES’ DETAILS SHALL BE SUBMITTED, REVIEWED AND ACCEPTED TO BE IN
ACCORDANCE WITH THE EROSION CONTROL CRITERIA BASED UPON THE FUNCTIONALITY AND EFFECTIVENESS IN ACCORDANCE WITH
SOUND ENGINEERING AND HYDROLOGICAL PRACTICES
LAND DISTURBANCE, STOCKPILES, AND STORAGE OF SOILS
20.THERE SHALL BE NO EARTH-DISTURBING ACTIVITY OUTSIDE THE LIMITS DESIGNATED ON THE ACCEPTED PLANS. OFF ROAD STAGING AREAS
OR STOCKPILES MUST BE PREAPPROVED BY THE CITY. DISTURBANCES BEYOND THESE LIMITS WILL BE RESTORED TO ORIGINAL CONDITION.
21.PRE-DISTURBANCE VEGETATION SHALL BE IDENTIFIED, PROTECTED, AND RETAINED WHEREVER POSSIBLE. REMOVAL OR DISTURBANCE OF
EXISTING VEGETATION SHALL BE LIMITED TO THE AREA REQUIRED FOR IMMEDIATE CONSTRUCTION OPERATIONS, AND FOR THE SHORTEST
PRACTICAL PERIOD OF TIME. THIS SHOULD INCLUDE SEQUENCING AND PHASING CONSTRUCTION ACTIVITIES IN A WAY SO THAT THE SOIL IS
NOT EXPOSED FOR LONG PERIODS OF TIME BY SCHEDULE OR LIMIT GRADING TO SMALL AREAS. THIS SHOULD ALSO INCLUDE WHEN
PRACTICAL ADVANCING THE SCHEDULE ON STABILIZATION ACTIVITIES SUCH THAT LANDSCAPING TAKES PLACE SHORTLY IF NOT
IMMEDIATELY AFTER GRADING HAS OCCURRED. VEGETATION EFFORTS SHALL START AS SOON AS POSSIBLE TO RETURN THE SITE TO A
STABILIZED CONDITION. SENSITIVE AREAS SHOULD AVOID CLEARING AND GRADING ACTIVITIES AS MUCH POSSIBLE.
22.ALL EXPOSED SOILS OR DISTURBED AREAS ARE CONSIDERED A POTENTIAL POLLUTANT AND SHALL HAVE CONTROL MEASURES
IMPLEMENTED ON THE SITE TO PREVENT MATERIALS FROM LEAVING THE SITE.
23.ALL SOILS EXPOSED DURING LAND DISTURBING ACTIVITY (STRIPPING, GRADING, UTILITY INSTALLATIONS, STOCKPILING, FILLING, ETC.)
SHALL BE KEPT IN A ROUGHENED CONDITION AT ALL TIMES BY EQUIPMENT TRACKING, SCARIFYING OR DISKING THE SURFACE ON A
CONTOUR WITH A 2 TO 4 INCH MINIMUM VARIATION IN SOIL SURFACE UNTIL MULCH, VEGETATION, AND/OR OTHER PERMANENT EROSION
CONTROL IS INSTALLED.
24.NO SOIL STOCKPILE SHALL EXCEED TEN (10) FEET IN HEIGHT. ALL SOIL STOCKPILES SHALL BE PROTECTED FROM SEDIMENT TRANSPORT
THROUGH THE USE OF SURFACE ROUGHENING, WATERING, AND DOWN GRADIENT PERIMETER CONTROLS. ALL SOIL STOCKPILES SHALL BE
PROTECTED FROM SEDIMENT TRANSPORT BY WIND IN ACCORDANCE WITH MUNICIPAL CODE §12-150. ALL STOCKPILES SHALL BE FLATTENED
TO MEET GRADE OR REMOVED FROM SITE AS SOON AS PRACTICAL, AND NO LATER THAN THE COMPLETION OF CONSTRUCTION ACTIVITIES
OR ABANDONMENT OF THE PROJECT. ALL OFF-SITE STOCKPILE STORAGE LOCATIONS IN CITY LIMITS SHALL HAVE A STOCKPILE PERMIT
FROM THE CITY ENGINEERING DEPARTMENT PRIOR TO USING THE AREA TO STORE MATERIAL. IF FREQUENT ACCESS FROM HARDSCAPE TO
THE STOCKPILE IS NEEDED A STRUCTURAL TRACKING CONTROL MEASURE SHALL BE IMPLEMENTED.
25.ALL REQUIRED CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITY (STOCKPILING, STRIPPING, GRADING,
ETC.). ALL OF THE REQUIRED EROSION CONTROL MEASURES MUST BE INSTALLED AT THE APPROPRIATE TIME IN THE CONSTRUCTION
SEQUENCE AS INDICATED IN THE APPROVED PROJECT SCHEDULE, CONSTRUCTION PLANS, AND EROSION CONTROL REPORT.
26.ALL INLETS, CURB-CUTS, CULVERTS, AND OTHER STORM SEWER INFRASTRUCTURE WHICH COULD BE POTENTIALLY IMPACTED BY
CONSTRUCTION ACTIVITIES SHALL BE PROTECTED WITH CONTROL MEASURES. MATERIAL ACCUMULATED FROM THIS CONTROL MEASURE
SHALL BE PROMPTLY REMOVED AND IN CASES WHERE THE PROTECTION HAS FAILED, THE PIPES SHALL BE THOROUGHLY CLEANED OUT.
27.ALL STREAMS, STREAM CORRIDORS, BUFFERS, WOODLANDS, WETLANDS, OR OTHER SENSITIVE AREAS SHALL BE PROTECTED FROM IMPACT
BY ANY CONSTRUCTION ACTIVITY THROUGH THE USE OF CONTROL MEASURES.
28.ALL EXPOSED DIRT SHALL HAVE PERIMETER CONTROL. ANY PERIMETER CONTROLS THAT DRAIN OFF OR HAS THE ABILITY TO BE TRACKED
ONTO THE NEARBY HARDSCAPE SHALL HAVE SOME FORM OF EFFECTIVE SEDIMENT CONTROL AS THE, OR AS PART OF THE, PERIMETER
CONTROL.
29.ALL EXPOSED SLOPES SHOULD BE PROTECTED. ALL EXPOSED STEEP SLOPES (STEEPER THAN 3:1 H:V) SHALL BE PROTECTED FROM
EROSION AND SEDIMENT TRANSPORT THROUGH USE OF CONTROL MEASURES.
30.NO SOILS SHALL REMAIN EXPOSED BY LAND DISTURBING ACTIVITY FOR MORE THAN THIRTY (30) DAYS AFTER ACTIVITY HAS CEASED
BEFORE REQUIRED TEMPORARY SEEDING OR PERMANENT EROSION CONTROL (E.G. SEED/MULCH, LANDSCAPING, ETC.) IS INSTALLED. THIS
IS NOT JUST LIMITED TO PROJECTS THAT ARE ABANDONED; THIS INCLUDES ANY PROJECT THAT IS TEMPORARILY HALTED AND NO
IMMEDIATE ACTIVITY IS TO RESUME WITHIN THE NEXT THIRTY (30) DAYS, UNLESS OTHERWISE APPROVED BY THE CITY EROSION CONTROL
INSPECTOR. DURING A SEASON WHEN SEEDING DOES NOT PRODUCE VEGETATIVE COVER, ANOTHER TEMPORARY EROSION CONTROL
SHALL BE IMPLEMENTED WITH OR UNTIL TEMPORARY SEEDING OR PERMANENT EROSION CONTROL CAN BE PERFORMED.
31.ALL INDIVIDUAL LOTS SHALL HAVE EFFECTIVE SEDIMENT CONTROLS LOCATED ON THE STREET SIDE AND ANY DOWN GRADIENT SIDE.
TYPICALLY MOST LOTS DRAIN TO THE FRONT YET ON THOSE CASES WHERE HOUSES ARE ALONG A POND OR DRAINAGE SWALE HAVE THE
LOT DRAIN IN A DIFFERENT DIRECTION THAN THE STREET, THOSE INDIVIDUAL LOTS WILL NEED PROTECTION ON THAT DOWN GRADIENT SIDE
TO PREVENT SEDIMENT FROM LEAVING THE LOT. SEE THE INDIVIDUAL LOT DETAILS FOR FURTHER CLARIFICATION.
VEHICLE TRACKING
32.AT ALL POINTS WHERE VEHICLES EXIT OR LEAVE THE EXPOSED DIRT AREA ON TO A HARDSCAPE OR SEMI HARDSCAPE (CONCRETE,
ASPHALT, ROAD BASE, ETC.) SHALL HAVE INSTALLED AT LEAST ONE STRUCTURAL TRACKING CONTROL MEASURE TO PREVENT VEHICLE
TRACKING. ALL AREAS NOT PROTECTED BY AN ADEQUATE PERIMETER CONTROL SHALL BE CONSIDERED A POINT WHERE VEHICLES EXIT
THE SITE. ACCESS POINTS SHOULD BE LIMITED TO AS FEW ENTRANCES AS POSSIBLE (ALL PERIMETER AREAS SHALL BE PROTECTED FROM
TRACKING ACTIVITIES).
33.IN ALL AREAS THAT THE STRUCTURAL TRACKING CONTROL MEASURES FAIL TO PREVENT VEHICLE TRACKING, COLLECTION AND PROPER
DISPOSAL OF THAT MATERIAL IS REQUIRED. ALL INLETS LOCATED NEAR ACCESS POINTS AND AFFECTED BY TRACKING ACTIVITIES SHALL BE
PREVENTED FROM THE INTRODUCTION OF SEDIMENT INTO THE DRAINAGE SYSTEM.
34.CITY MUNICIPAL CODE §20-62, AMONG OTHER THINGS, PROHIBITS THE TRACKING, DROPPING, OR DEPOSITING OF SOILS OR ANY OTHER
MATERIAL ONTO CITY STREETS BY OR FROM ANY SOURCE. CITY MUNICIPAL CODE, §26-498, AMONG OTHER THINGS, PROHIBITS THE
DISCHARGE OF POLLUTANTS ON PUBLIC OR PRIVATE PROPERTY IF THERE IS A SIGNIFICANT POTENTIAL FOR MIGRATION OF SUCH
POLLUTANT. THEREFORE, ALL TRACKED OR DEPOSITED MATERIALS (INTENTIONAL OR INADVERTENT) ARE NOT PERMITTED TO REMAIN ON
THE STREET OR GUTTER AND SHALL BE REMOVED AND LEGALLY DISPOSED OF BY THE DEVELOPER IN A TIMELY AND IMMEDIATE MANNER.
DIRT RAMPS INSTALLED IN THE CURB-LINES ARE NOT EXEMPT TO THESE SECTIONS OF CODE AND SHALL NOT BE PERMITTED IN THE STREET
RIGHT OF WAY (PUBLIC OR PRIVATE).
35.IF REPEATED DEPOSIT OF MATERIAL OCCURS ON A SITE, ADDITIONAL STRUCTURAL TRACKING CONTROLS MAY BE REQUIRED OF THE
DEVELOPER BY THE CITY EROSION CONTROL INSPECTOR.
LOADING AND UNLOADING OPERATIONS
36.THE DEVELOPER SHALL APPLY CONTROL MEASURE TO LIMIT TRAFFIC (SITE WORKER OR PUBLIC) IMPACTS AND PROACTIVELY LOCATE
MATERIAL DELIVERED TO THE SITE IN CLOSE PROXIMITY TO THE WORK AREA OR IMMEDIATELY INCORPORATED IN THE CONSTRUCTION TO
LIMIT OPERATIONAL IMPACTS TO DISTURBED AREAS, VEHICLE TRACKING, AND SEDIMENT DEPOSITION THAT COULD IMPACT WATER
QUALITY.
OUTDOOR STORAGE OR CONSTRUCTION SITE MATERIALS, BUILDING MATERIALS, FERTILIZERS, AND CHEMICALS
37.ANY MATERIALS OF A NON-POLLUTING NATURE (STEEL, ROCK, BRICK, LUMBER, ETC.) SHALL BE INSPECTED FOR ANY RESIDUE COMING OFF
THE MATERIAL DURING ROUTINE INSPECTION AND WILL GENERALLY BE LOCATED WHERE PRACTICAL AT LEAST FIFTY (50) FEET FROM ANY
PERMANENT OR INTERIM DRAINAGE WAYS.
38.ANY HIGH ENVIRONMENTAL IMPACT POLLUTANT MATERIALS THAT HAVE A HIGH LIKELIHOOD TO RESULT IN DISCHARGE WHEN IN CONTACT
WITH STORMWATER (LUBRICANTS, FUELS, PAINTS, SOLVENTS, DETERGENTS, FERTILIZERS, CHEMICAL SPRAYS, BAGS OF CEMENT MIX, ETC.)
SHOULD NOT BE KEPT ON SITE WHERE PRACTICAL. WHEN NOT PRACTICAL, THEY SHOULD BE STORED INSIDE (VEHICLE, TRAILER, CONNEX,
BUILDING, ETC.) AND OUT OF CONTACT WITH STORMWATER OR STORMWATER RUNOFF. WHERE NOT AVAILABLE, THEY SHALL BE STORED
OUTSIDE IN A RAISED (HIGH SPOTS OR ON PALLETS), COVERED (PLASTIC OR TARPED), AND SEALED (LEAK PROOF CONTAINER) IN
SECONDARY CONTAINMENT LOCATION. THE SECONDARY CONTAINMENT OR OTHER CONTROL MEASURE SHALL BE ADEQUATELY SIZED,
LOCATED, WHERE PRACTICAL, AT LEAST FIFTY (50) FEET FROM ANY PERMANENT OR INTERIM STORMWATER STRUCTURES OR DRAINAGE
WAYS AND SHALL BE MONITORED AS PART OF THE ROUTINE INSPECTIONS.
VEHICLE AND EQUIPMENT MAINTENANCE AND FUELING
39.PARKING, REFUELING, AND MAINTENANCE OF VEHICLES AND EQUIPMENT SHOULD BE LIMITED IN ONE AREA OF THE SITE TO MINIMIZE
POSSIBLE SPILLS AND FUEL STORAGE AREAS. THIS AREA SHALL BE LOCATED, WHERE PRACTICAL, AT LEAST FIFTY (50) FEET FROM ANY
PERMANENT OR INTERIM STORMWATER STRUCTURES OR DRAINAGE WAYS AND SHALL BE MONITORED AS PART OF THE ROUTINE
INSPECTIONS. ALL AREAS SHALL KEEP SPILL KITS AND SUPPLIES CLOSE.
SIGNIFICANT DUST OR PARTICULATE GENERATING PROCESS
40.THE PROPERTY MUST BE ACTIVELY PREVENTING THE EMISSION OF FUGITIVE DUST AT ALL TIMES DURING CONSTRUCTION AND VEGETATION
ACTIVITIES. ALL LAND DISTURBING ACTIVITIES THAT RESULT IN FUGITIVE DUST SHALL BE IN ACCORDANCE WITH MUNICIPAL CODE §12-150
TO REDUCE THE IMPACTS TO ADJACENT PROPERTIES AND COMMUNITY HEALTH. ALL REQUIRED PRACTICES SHALL BE IMPLEMENTED AND
ADDITIONAL ONES SHALL BE FOLLOWED. THESE PRACTICES INCLUDE WATERING THE SITES AND DISCONTINUING CONSTRUCTION
ACTIVITIES UNTIL THE WIND SUBSIDES AS DETERMINED BY ANY CITY INSPECTORS. CONCRETE TRUCK / EQUIPMENT WASHING, INCLUDING
THE CONCRETE TRUCK CHUTE AND ASSOCIATED FIXTURES AND EQUIPMENT
41.ALL CONCRETE AND EQUIPMENT WASHING SHALL USE STRUCTURAL CONTROL MEASURES APPROPRIATE TO THE VOLUME OF WASH AND
FREQUENCY OF USE. THESE CONTROL MEASURES SHALL BE LOCATED, WHERE PRACTICAL, AT LEAST FIFTY (50) FEET FROM ANY
PERMANENT OR INTERIM STORMWATER STRUCTURES OR DRAINAGE WAYS AND SHALL BE MONITORED AS PART OF THE ROUTINE
INSPECTIONS. THESE AREAS SHALL BE CLEARLY IDENTIFIED AND PROTECTED FROM ANY WASH FROM LEAVING THE CONTROL MEASURE. IF
FREQUENT ACCESS FROM HARDSCAPE TO THE CONTROL MEASURE IS TO OCCUR, A STRUCTURAL TRACKING CONTROL MEASURE SHALL BE
IMPLEMENTED. THESE CONTROL MEASURES SHALL BE FREQUENTLY CLEANED OUT.
42.THE DEVELOPER IS RESPONSIBLE FOR ENSURING WASHING ACTIVITY IS TAKING PLACE AT THE APPROPRIATE CONTROL MEASURE AND SITE
WORKERS ARE NOT WASHING OR DUMPING WASH WATER ON TO THE DIRT OR OTHER UNCONTROLLED LOCATIONS.
DEDICATED ASPHALT AND CONCRETE BATCH PLANTS
43.DEDICATED ASPHALT AND CONCRETE BATCH PLANTS ARE NOT ACCEPTABLE ON CONSTRUCTION SITES WITHIN THE CITY OF FORT COLLINS
WITHOUT AN EXPRESSED WRITTEN REQUEST AND PLAN TO REDUCE POLLUTANTS ASSOCIATED WITH THAT TYPE OF ACTIVITY AND
APPROVAL BY THE CITY OF FORT COLLINS SPECIFICALLY THE EROSION CONTROL INSPECTOR. THE DEVELOPER SHALL INFORM THE
EROSION CONTROL INSPECTION STAFF OF ANY DEDICATED ASPHALT, OR CONCRETE BATCH PLANTS THAT IS TO BE USED ON SITE.
CONCRETE SAW CUTTING MATERIALS
44.SAW CUTTING MATERIAL SHALL BE IN ACCORDANCE WITH MUNICIPAL CODE §12-150 FOR AIR EMISSIONS AND ALL WATER APPLICATIONS TO
THE SAW CUTTING SHALL PREVENT MATERIAL FROM LEAVING THE IMMEDIATE SITE AND COLLECTED. THESE CUTTING LOCATIONS, ONCE
DRIED, SHALL BE SWEPT AND SCRAPED OF ALL MATERIAL AND SHALL HAVE PROPER AND LEGAL DISPOSAL.
WASTE MATERIALS STORAGE AND SANITARY FACILITIES
45.TRASH, DEBRIS, MATERIAL SALVAGE, AND/OR RECYCLING AREAS SHALL BE, WHERE PRACTICAL, AT LEAST FIFTY (50) FEET FROM ANY
PERMANENT OR INTERIM STORMWATER STRUCTURES OR DRAINAGE WAYS AND SHALL BE MONITORED AS PART OF THE ROUTINE
INSPECTIONS. THESE FACILITIES SHOULD BE LOCATED OUT OF THE WIND AND COVERED AS ABLE. WHERE NOT ABLE TO COVER, LOCATING
SAID AREAS ON THE SIDE OF OTHER STRUCTURES TO REDUCE EXPOSURE TO WINDS, AND FOLLOW MAXIMUM LOADING GUIDELINES AS
MARKED ON THE CONTAINER. THE DEVELOPER IS REQUIRED TO PRACTICE GOOD HOUSEKEEPING TO KEEP THE CONSTRUCTION SITE FREE
OF LITTER, CONSTRUCTION DEBRIS, AND LEAKING CONTAINERS.
46.SANITARY FACILITIES SHALL BE PREVENTED FROM TIPPING THROUGH THE USE OF ANCHORING TO THE GROUND OR LASHING TO A
STABILIZED STRUCTURE. THESE FACILITIES SHALL ALSO BE LOCATED AS FAR AS PRACTICAL FROM AN INLET, CURB CUT, DRAINAGE SWALE
OR OTHER DRAINAGE CONVEYANCES TO PREVENT MATERIAL TRANSPORT FROM LEAVING THE LOCAL AREA. THIS CONSISTS OF THE
FACILITY BEING LOCATED, WHERE PRACTICAL, AT LEAST FIFTY (50) FEET FROM ANY PERMANENT OR INTERIM DRAINAGE WAYS.
OTHER SITE OPERATIONS AND POTENTIAL SPILL AREAS
47.SPILLS: FOR THOSE MINOR SPILLS THAT; ARE LESS THAN THE STATE’S REPORTABLE QUANTITY FOR SPILLS, STAY WITHIN THE PERMITTED
AREA, AND IN NO WAY THREATEN ANY STORMWATER CONVEYANCE, NOTIFY THE CITY OF FORT COLLINS UTILITIES BY EMAIL AT
EROSION@FCGOV.COM OR PHONE (970) 817-4770. FOR ANY SIGNIFICANT, MAJOR, OR HAZARDOUS SPILLS, NOTIFY THE CITY OF FORT
COLLINS UTILITIES BY PHONE ONLY AFTER EMERGENCY RESPONSE (911) HAS BEEN NOTIFIED AND IS ON ROUTE, COUNTY HEALTH
DEPARTMENT (LCDHE) HAS BEEN NOTIFIED THROUGH LARIMER COUNTY SHERIFF DISPATCH (970) 416-1985, AND THE STATE SPILL HOTLINE
INCIDENT REPORTING HAVE BEEN CONTACTED 1-877-518-5608. WRITTEN DOCUMENTATION SHALL BE PROVIDED TO THE CITY WITHIN 5 DAYS
OF THE EVENT. ALL SPILLS SHALL BE CLEANED UP IMMEDIATELY.
48.SELECTION OF “PLASTIC WELDED” EROSION CONTROL BLANKETS SHALL NOT BE USED IN AREAS THAT WILDLIFE, SUCH AS SNAKES, ARE
LIKELY TO BE LOCATED AS THESE HAVE PROVEN TO CAUSE ENTRAPMENT ISSUES.
FINAL STABILIZATION AND PROJECT COMPLETION
49.ANY STORMWATER FACILITIES USED AS A TEMPORARY CONTROL MEASURE WILL BE RESTORED AND STORM SEWER LINES WILL BE
CLEANED UPON COMPLETION OF THE PROJECT AND BEFORE TURNING THE MAINTENANCE OVER TO THE OWNER, HOMEOWNERS
ASSOCIATION (HOA), OR OTHER PARTY RESPONSIBLE FOR LONG TERM MAINTENANCE OF THOSE FACILITY.
50.ALL FINAL STABILIZATION SPECIFICATIONS SHALL BE DONE IN ACCORDANCE WITH THE MANUAL, CHAPTER 4: CONSTRUCTION CONTROL
MEASURES.
51.ALL DISTURBED AREAS DESIGNED TO BE VEGETATED SHALL BE AMENDED, SEEDED & MULCHED, OR LANDSCAPED AS SPECIFIED IN THE
LANDSCAPE PLANS AND PER CITY OF FORT COLLINS STANDARDS WITHIN 14 WORKING DAYS OF FINAL GRADING.
52.SOIL IN ALL VEGETATED (LANDSCAPED OR SEEDED) AREAS, INCLUDING PARKWAYS AND MEDIANS SHALL COMPLY WITH ALL REQUIREMENTS
SET FORTH IN SECTIONS 12-130 THROUGH 12-132 OF THE CITY MUNICIPAL CODE, AS WELL AS SECTION 3.8.21 FOR THE CITY LAND USE CODE.
53.ALL SEEDING SHALL REFER TO LANDSCAPING PLANS OR THE EROSION CONTROL PLANS FOR SPECIES MIXTURE AND APPLICATION RATES
AND DEPTHS REQUIREMENTS.
54.ALL SEED SHALL BE DRILLED WHERE PRACTICAL TO A DEPTH BASED UPON THE SEED TYPE. BROADCAST SEEDING SHALL BE APPLIED AT
DOUBLE THE RATE AS PRESCRIBED FOR DRILL SEEDING AND SHALL BE LIGHTLY HAND RAKED AFTER APPLICATION. HYDROSEEDING MAY BE
SUBSTITUTED FOR DRILL SEEDING ON SLOPES STEEPER THAN 3(H):1(V) OR ON OTHER AREAS NOT PRACTICAL TO DRILL SEED AND CRIMP
AND MULCH. ALL HYDROSEEDING MUST BE CONDUCTED AS TWO SEPARATE PROCESSES OF SEEDING AND TACKIFICATION.
55.ALL SEEDED AREAS MUST BE MULCHED WITHIN TWENTY-FOUR (24) AFTER PLANTING. ALL MULCH SHALL BE MECHANICALLY CRIMPED AND
OR ADEQUATELY APPLIED TACKIFIER. THE USE OF CRIMPED MULCH OR TACKIFIER MAY REQUIRE MULTIPLE RE-APPLICATIONS IF NOT
PROPERLY INSTALLED OR HAVE WEATHERED OR DEGRADED BEFORE VEGETATION HAS BEEN ESTABLISHED. AREAS OF EMBANKMENTS
HAVING SLOPES GREATER THAN OR EQUAL TO 3H:1V SHALL BE STABILIZED WITH AN EROSION MAT OR APPROVED EQUAL TO ENSURE SEED
WILL BE ABLE TO GERMINATE ON THE STEEP SLOPES. DURING A SEASON WHEN SEEDING DOESNOT PRODUCE VEGETATIVE COVER,
ANOTHER TEMPORARY EROSION CONTROL SHALL BE IMPLEMENTED ALONG WITH, OR UNTIL, TEMPORARY SEEDING OR PERMANENT
EROSION CONTROL CAN BE PERFORMED.
56.THE DEVELOPER SHALL WARRANTY AND MAINTAIN ALL VEGETATIVE MEASURES FOR TWO GROWING SEASONS AFTER INSTALLATION OR
UNTIL SEVENTY PERCENT (70%) VEGETATIVE COVER HAS BEEN ESTABLISHED, WHICHEVER IS LONGER AND MEETS ALL THE CRITERIA
OUTLINED IN THE FORT COLLINS STORMWATER CRITERIA MANUAL CHAPTER 4: CONSTRUCTION CONTROL MEASURES.
57.THE DEVELOPER SHALL MAINTAIN, MONITOR, REPAIR, AND REPLACE ANY AND ALL APPLICABLE CONTROL MEASURES UNTIL FINAL
STABILIZATION HAS BEEN OBTAINED. ALL CONTROL MEASURES MUST REMAIN UNTIL SUCH TIME AS ALL UPSTREAM CONTRIBUTING
POLLUTANT SOURCES HAVE BEEN VEGETATED OR REMOVED FROM THE SITE. WHEN ANY CONTROL MEASURE IS REMOVED, THE
DEVELOPER SHALL BE RESPONSIBLE FOR THE CLEANUP AND REMOVAL OF ALL SEDIMENT AND DEBRIS FROM THAT CONTROL MEASURE. AT
THE POINT AT WHICH THE SITE HAS BEEN DEEMED STABILIZED AND VERIFIED BY CITY EROSION CONTROL INSPECTOR, ALL TEMPORARY
CONTROL MEASURES CAN THEN BE FULLY REMOVED. ALL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL STABILIZATION IS
ACHIEVED.
58.THE RESPONSIBLE PARTY SHALL MAINTAIN AND KEEP CURRENT ALL PAYMENTS OR RELATED FORMS OF SECURITY FOR THE EROSION
CONTROL ESCROW UNTIL 1) STABILIZATION HAS BEEN REACHED AND 2) ALL CONTROL MEASURES AND/OR BMPS HAVE SEDIMENT
MATERIALS COLLECTED AND THE CONTROL MEASURE REMOVED FROM THE SITE. AT THAT TIME THE SITE WILL BE CONSIDERED COMPLETED
AND ANY REMAINING EROSION CONTROL ESCROW SHALL BE RETURNED TO THE APPROPRIATE PARTIES.
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
ER
O
S
I
O
N
C
O
N
T
R
O
L
N
O
T
E
S
6
N/A
N/A
C 300
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
NORTH LIN
K
L
A
N
E
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S
F
SF
SF
SF
SF SF
SF
SF
SF
SF
SF
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: THE LANDING AT LEMAY
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Straw Wattles *
Inlet Protection *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Concrete Washout Area*
Rock Socks *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
P
R
E
C
O
N
S
T
R
U
C
T
I
O
N
)
7
1" = 50'
N/A
C 301
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROJECT DATUM: NAVD88
BENCHMARK 12-07: SOUTH SIDE OF VINE DR. ON THE SOUTH
HEADWALL OF THE BRIDGE OVER DRY CREEK BASIN 0.4 MILES
EAST OF NORTH LEMAY AVE.
ELEVATION: 4947.86
BENCHMARK 8-02: ON THE SOUTHEAST CORNER OF THE
INTERSECTION OF LEMAY AVENUE AND MULBERRY STREET, IN
THE CURB, ON THE SOUTHEAST SIDE OF A TRIANGULAR ISLAND
THAT CONTAINS THE TRAFFIC SIGNAL.
ELEVATION: 4939.27
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM)
FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS
DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM
(PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.18'.
SILT FENCE
ROCK SOCK
TURF REINFORCEMENT MAT (SCOUR STOP)
1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY
CRIMP MULCHING OR SIMILAR METHODS.
2.SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 19.65 AC.
4.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
5.REFER TO THE FINAL DRAINAGE REPORT, DATED NOVEMBER 15, 2023 BY
AVANT CIVIL GROUP FOR ADDITIONAL INFORMATION.
6.REFER TO THE FINAL SWMP REPORT DATED NOVEMBER 15, 2023 FOR
FURTHER DETAILS AND EROSION CONTROL BEST PRACTICES
WATTLE DIKE
CONCRETE WASH AREA
EC BLANKET (SLOPE STABILIZATION)
OUTLET PROTECTION
INLET PROTECTION
VEHICLE TRACKING CONTROL PAD
SF
LEGEND
PROJECT BENCHMARKS
NOTES
STABILIZED STAGING AREA
100'x200' LAYDOWN AREA
U
D
UD
UD
UD
UD
UD
UDUD
UD
U
D
UD
UD
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
/ / / / / / / /
/ / / / / / / /
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
NORTH LIN
K
L
A
N
E
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
S
F
SF
SF
SF
SF SF
SF
SF
SF
SF
SF
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
0.
3
%
0.
5
%
0.
1
%
0.
6
%
0.
5
%
0.
4
%
0.
5
%
0.
4
%
0.
5
%
0.
5
%
0.
5
%
0.6%0.5%0.6%0.6%
0.6%
0.6%
0.3%
0.6%
0.
6
%
0.
4
%
0.
4
%
0.
4
%
0.
6
%
0.
6
%
0.6%
0.6%
0.
6
%
1.0%
1.
6
%
0.
6
%
2.9%
0.5%
0.0%0.0%
0.
2
%
0.
5
%
0.5%
0.
6
%
0.6%
0.
6
%
0.
6
%
0.6%
0.4%
0.4%
0.7%
0.
4
%
0.
1
%
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: THE LANDING AT LEMAY
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Straw Wattles *
Inlet Protection *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Concrete Washout Area*
Rock Socks *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2' CONCRETE PAN
PROPOSED STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED STORM DRAIN
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
D
U
R
I
N
G
C
O
N
S
T
R
U
C
T
I
O
N
)
8
1" = 50'
N/A
C 302
CO
R
D
O
V
A
R
O
A
D
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROJECT DATUM: NAVD88
BENCHMARK 12-07: SOUTH SIDE OF VINE DR. ON THE SOUTH
HEADWALL OF THE BRIDGE OVER DRY CREEK BASIN 0.4 MILES
EAST OF NORTH LEMAY AVE.
ELEVATION: 4947.86
BENCHMARK 8-02: ON THE SOUTHEAST CORNER OF THE
INTERSECTION OF LEMAY AVENUE AND MULBERRY STREET, IN
THE CURB, ON THE SOUTHEAST SIDE OF A TRIANGULAR ISLAND
THAT CONTAINS THE TRAFFIC SIGNAL.
ELEVATION: 4939.27
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM)
FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS
DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM
(PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.18'.
SILT FENCE
ROCK SOCK
TURF REINFORCEMENT MAT (SCOUR STOP)
1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY
CRIMP MULCHING OR SIMILAR METHODS.
2.SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 19.65 AC.
4.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
5.REFER TO THE FINAL DRAINAGE REPORT, DATED NOVEMBER 15, 2023 BY
AVANT CIVIL GROUP FOR ADDITIONAL INFORMATION.
6.REFER TO THE FINAL SWMP REPORT DATED NOVEMBER 15, 2023 FOR
FURTHER DETAILS AND EROSION CONTROL BEST PRACTICES
WATTLE DIKE
CONCRETE WASH AREA
EC BLANKET (SLOPE STABILIZATION)
OUTLET PROTECTION
INLET PROTECTION
VEHICLE TRACKING CONTROL PAD
SF
LEGEND
PROJECT BENCHMARKS
NOTES
STABILIZED STAGING AREA
SF
SF
SF
SF SF SF
SFSF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
SF
ENSURE CONSISTENT SWEEPING AT ENTRANCES
ENSURE CONSISTENT SWEEPING AT ENTRANCES
U
D
UD
UD
UD
UD
UD
UDUD
UD
U
D
UD
UD
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
/ / / / / / / /
/ / / / / / / /
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
NORTH LIN
K
L
A
N
E
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
0.
3
%
0.
5
%
0.
1
%
0.
6
%
0.
5
%
0.
4
%
0.
5
%
0.
4
%
0.
5
%
0.
5
%
0.
5
%
0.6%0.5%0.6%0.6%
0.6%
0.6%
0.3%
0.6%
0.
6
%
0.
4
%
0.
4
%
0.
4
%
0.
6
%
0.
6
%
0.6%
0.6%
0.
6
%
1.0%
1.
6
%
0.
6
%
2.9%
0.5%
0.0%0.0%
0.
2
%
0.
5
%
0.5%
0.
6
%
0.6%
0.
6
%
0.
6
%
0.6%
0.4%
0.4%
0.7%
0.
4
%
0.
1
%
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY
CRIMP MULCHING OR SIMILAR METHODS.
2.SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 19.65 AC.
4.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
5.REFER TO THE FINAL DRAINAGE REPORT, DATED NOVEMBER 15, 2023 BY
AVANT CIVIL GROUP FOR ADDITIONAL INFORMATION.
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION
Project: THE LANDING AT LEMAY
CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING
BEST MANAGEMENT PRACTICES (BMPS)
STRUCTURAL "INSTALLATION"
Silt Fence Barriers *
Straw Wattles *
Inlet Protection *
Vegetative
Temporary Seeding Planting
Mulching / Sealant
Permanent Seeding Planting
Sod Installation
Rolled Products : Netting / Blankets / Mats
Concrete Washout Area*
Rock Socks *
UTILITIES
INSTALLATION
FLAT WORK
INSTALLATION
VERTICAL
INSTALLATION LANDSCAPE DEMOBILIZATION
Vehicle Tracking Pad *
* All Temporary BMPs to be Removed once Construction is Complete
Any prior inlets that could use protecting
Any prior inlets that could use protecting
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
Anytime the site will sit dormant longer than 30 Days
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
NOTES
PROPOSED STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED STORM DRAIN
PROPOSED 2' CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
ER
O
S
I
O
N
C
O
N
T
R
O
L
P
L
A
N
(
P
O
S
T
C
O
N
S
T
R
U
C
T
I
O
N
)
9
1" = 50'
N/A
C 303
CO
R
D
O
V
A
R
O
A
D
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROJECT DATUM: NAVD88
BENCHMARK 12-07: SOUTH SIDE OF VINE DR. ON THE SOUTH
HEADWALL OF THE BRIDGE OVER DRY CREEK BASIN 0.4 MILES
EAST OF NORTH LEMAY AVE.
ELEVATION: 4947.86
BENCHMARK 8-02: ON THE SOUTHEAST CORNER OF THE
INTERSECTION OF LEMAY AVENUE AND MULBERRY STREET, IN
THE CURB, ON THE SOUTHEAST SIDE OF A TRIANGULAR ISLAND
THAT CONTAINS THE TRAFFIC SIGNAL.
ELEVATION: 4939.27
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM)
FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS
DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM
(PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.18'.
SILT FENCE
ROCK SOCK
TURF REINFORCEMENT MAT (SCOUR STOP)
1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY
CRIMP MULCHING OR SIMILAR METHODS.
2.SWMP ADMINISTRATOR:
Contact ________________________________
Company ________________________________
Address ________________________________
Phone ________________________________
3.TOTAL DISTURBED AREA OF CONSTRUCTION = 19.65 AC.
4.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE
WASHOUT AREA IF ACCESS IS OFF PAVEMENT.
5.REFER TO THE FINAL DRAINAGE REPORT, DATED NOVEMBER 15, 2023 BY
AVANT CIVIL GROUP FOR ADDITIONAL INFORMATION.
6.REFER TO THE FINAL SWMP REPORT DATED NOVEMBER 15, 2023 FOR
FURTHER DETAILS AND EROSION CONTROL BEST PRACTICES
WATTLE DIKE
CONCRETE WASH AREA
EC BLANKET (SLOPE STABILIZATION)
OUTLET PROTECTION
INLET PROTECTION
VEHICLE TRACKING CONTROL PAD
SF
LEGEND
PROJECT BENCHMARKS
NOTES
STABILIZED STAGING AREA
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SF
VTC
ROCK SOCK SECTION ROCK SOCK PLAN
ROCK SOCK JOINTING
GRADATION TABLE
SIEVE SIZE
MASS PERCENT
PASSING SQUARE
MESH SIEVES
NO. 4
2"100
1-1/2"90-100
1"20-55
3/4"0-15
3/8"0-5
MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR
CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,
ALL SIDES
RS
CWA
AA
PLAN VIEW
SECTION A-A
2:1
OP
WQCV
AT PIPE OUTLET AREAS OF STREAMS AND
DRAINAGE CHANNELS - DETAIL A
IN DIVERSION DITCH OR SMALL DITCH DRAINAGE WAY - DETAIL B
OUTSIDE OF STREAMS AND DRAINAGE CHANNELS - DETAIL C
ANCHOR DETAILS
PERIMETER ANCHOR TRENCH
JOINT ANCHOR TRENCH
INTERMEDIATE ANCHOR TRENCH
OVERLAPPING JOINT
WOOD STAKE DETAIL
MINIMUM THICKNESS 1"
USE 2x4 MATERIAL FOR STAKES
JOINT ANCHOR
TRENCH, TYP.
PERIMETER
ANCHOR
TRENCH, TYP.
TOP OF
CHANNEL BANK
TYPE OF BLANKET AS INDICATED IN PLAN VIEW, IN ALL DISTURBED AREAS OF
STREAMS AND DRAINAGE CHANNELS TO DEPTH "D" ABOVE CHANNEL INVERT.
BLANKET SHALL GENERALLY BE ORIENTED PARALLEL TO FLOW DIRECTION.
STAKING PATTERN SHALL MATCH BLANKET TYPE.
UNDISTURBED
SOIL
TYPE OF BLANKET,
INDICATED IN PLAN VIEW PER MANUFACTURER SPEC. OR TYPE 2 OR 3 STAKING
(MATCH SPECIFIED BLANKET TYPE) SEE THE STAKING
PATTERNS DETAIL ON NEXT SHEET
PERIMETER
ANCHOR TRENCH, TYP.
JOINT ANCHOR TRENCH, TYP.
COMPACTED
SUBGRADE
1
>3
THE BLANKET SHALL
BE EXTENDED TO THE
TOP OF CHANNEL
"D
"
6
"
TO
P
S
O
I
L
"M"
OVERLAPPING JOINT, SEE
DETAIL ON THIS SHEET
STAGGER
OVERLAPS
PERIMETER ANCHOR TRENCH
SEE DETAIL ON THIS SHEET
PER MANUFACTURER SPEC.
OR TYPE 1 STAKING SEE
THE STAKING PATTERN
DETAIL ON NEXT SHEET
BLANKET SHALL BE
100% STRAW MIN.
DIVERSION DITCH
TYPICALLY AT
TOP OF SLOPE
6
"
TO
P
S
O
I
L
6" MIN.
(TYP.)
3" MIN.
(TYP.)
SINGLE EDGE
EROSION CONTROL
BLANKET (TYP.)
COMPACTED
BACKFILL (TYP.)
STAKE (TYP.)
TWO EDGES OF
TWO ADJACENT
ROLLS
LOOP FROM
MIDDLE OF
ROLL
FLOW 6"
3" MIN.
1
2
"
MI
N
.
STAKING PATTERNS
SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION. IF NO MANUFACTURER'S
SPECIFICATION IS AVAILABLE USE THE ACCEPTABLE STAKING PATTERN (AS SHOWN ABOVE)
PERIMETER ANCHOR
TRENCH OR JOINT
ANCHOR TRENCH, TYP.
STRAW-COCONUT
COCONUT OR EXCELSIOR
STRAW
ROLL WIDTH
"W" (TYP.)
6'
3'1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"
1/2 "W"
4'
3'
2'
SS
EROSION CONTROL BLANKET TYPE
TYPE
STRAW*
STRAW-COCONUT
EXCELSIOR
COCONUT
CONTENT
-
30% MIN.
-
STRAW
CONTENT
100%
-
NETTING MIN.
DOUBLE/NATURAL
100%
-
-
EXCELSIOR
CONTENT
COCONUT --100%
* FOR OUTSIDE OF STREAMS AND DRAINAGE CHANNELS
DOUBLE/NATURAL
DOUBLE/NATURAL
DOUBLE/NATURAL
MAX.70%
IP
36" ANCHOR STRAP
BULLET ANCHOR
RECESSED LOCK
WASHER
TRANSITION MAT
TURF
REINFORCEMENT
MAT
ANCHOR PATTERN
ANCHOR ILLUSTRATION
MAX. 1"-2" DROP
FROM CULVERT FLOWLINE
ONTO SCOURSTOP MATS
PROFILE VIEW
SECTION VIEW AA
OUTLET AND CHANNEL SCOUR PROTECTION
(TRANSITION MATS)
DIRECTION OF FLOW
TURF REINFORCEMENT MAT
WIDTH OF
PROTECTION
LENGTH OF PROTECTION
D
D= CULVERT DIAMETER
TRAN
S
I
T
I
O
N
M
A
T
S
SOIL
C
O
V
E
R
A
A
CULVERT OUTLET PROTECTION - PLAN VIEW
INSTALL ANCHORS PER SCOURSTOP INSTALLATION GUIDELINES
MINIMUM DEPTH 24" IN COMPACTED, COHESIVE SOIL.
MINIMUM DEPTH 30" IN LOOSE, SANDY, OR WET SOIL
EXTRA ANCHORS AS NEEDED TO SECURE MAT TIGHTLY OVER SOIL
COVER
ABUT TRANSITIONS MATS TO END OF CULVERT OR CULVERT APRON.
ADJACENT MATS ABUT TOGETHER LATERALLY AND LONGITUDINALLY.
MINIMUM 8 ANCHORS PER MAT.
EXTRA ANCHORS AS NEEDED FOR LOOSE OR WET SOILS.
PROTECT BARE/ DISTURBED DOWNSTREAM
SOILS FROM EROSION WITH APPROPRIATE
SOIL COVER.
NOTE:
1.SCOUR STOP MAT PRODUCT UTILIZED FOR TURF REINFORCEMENT MAT DIMENSIONS. OTHER TURF REINFORCEMENT MAT
PRODUCTS EQUAL TO OR BETTER ALLOWED WITH APPROVAL OF THE ENGINEER AND CITY.
2.SEEDING AT OUTFALL OF STORM SEWER SHALL BE COMPLETED PRIOR TO INSTALLATION OF TURF REINFORCEMENT MAT.
TRM
SEEDING TO OCCUR
PRIOR TO INSTALLATION
IP
FL
O
W
3'-4'
ADJACENT ROLLS SHALL
TIGHTLY ABUT
W1 NOTES:
INSTALLATION:
WHEN INSTALLING RUNNING LENGTHS OF WATTLES, BUTT
THE SECOND WATTLE TIGHTLY AGAINST THE FIRST, DO
NOT OVERLAP THE ENDS. STAKE THE WATTLES AT EACH
END AND FOUR FOOT ON CENTER. FOR EXAMPLE:
A 25 FOOT WATTLE USES 6 STAKES
A 20 FOOT WATTLE USES 5 STAKES
A 12 FOOT WATTLE USES 4 STAKES
STAKES SHOULD BE DRIVEN THROUGH THE MIDDLE OF
THE WATTLE. LEAVING 2 - 3 INCHES OF THE STAKE
PROTRUDING ABOVE THE WATTLE. A HEAVY SEDIMENT
LOAD WILL TEND TO PICK THE WATTLE UP AND COULD
PULL IT OFF THE STAKES IF THEY ARE DRIVEN DOWN TOO
LOW. IT MAY BE NECESSARY TO MAKE A HOLE IN THE
WATTLE WITH A PICK END OF YOUR MADDOX IN ORDER TO
GET THE STAKE THROUGH THE STRAW. WHEN STRAW
WATTLES ARE USED FOR FLAT GROUND APPLICATIONS,
DRIVE THE STAKES STRAIGHT DOWN; WHEN INSTALLING
WATTLES ON SLOPES, DRIVE THE STAKES
PERPENDICULAR TO THE SLOPE.
DRIVE THE FIRST END STAKE OF THE SECOND WATTLE AT
AN ANGLE TOWARD THE FIRST WATTLE IN ORDER TO HELP
ABUT THEM TIGHTLY TOGETHER. IF YOU HAVE DIFFICULTY
DRIVING THE STAKE INTO EXTREMELY HARD OR ROCKY
SLOPES, A PILOT BAR MAY BE NEEDED TO BEGIN THE
STAKE HOLE.
1"x 1" WOOD STAKES
18"-24"
BAILING WIRE OR
NYLON ROPE
WATTLE "A"WATTLE "B"
1'2'
TYP.
1'1'
W2 NOTES:
INSTALLATION:
STAKES SHOULD BE DRIVEN ACROSS
FROM EACH OTHER AND ON EACH
SIDE OF THE WATTLE. LEAVING 4"-6"
OF STAKE PROTRUDING ABOVE THE
WATTLE. BAILING WIRE OR NYLON
ROPE SHOULD BE TIED TO THE
STAKES ACROSS THE WATTLE.
STAKES SHOULD THEN BE DRIVEN
UNTIL THE BAILING WIRE OR NYLON
ROPE IS SUFFICIENTLY SNUG TO THE
WATTLE.
WHEN INSTALLING RUNNING LENGTHS
OF WATTLES, TO PREVENT SHIFTING,
BUTT THE SECOND WATTLE TIGHTLY
AGAINST THE FIRST. DO NOT
OVERLAP THE ENDS. STAKES
SHOULD BE DRIVEN 1 FT. FROM END,
ACROSS FROM AND ON EACH SIDE OF
WATTLE LEAVING 4"-6" OF STAKE
PROTRUDING ABOVE THE WATTLE.
BAILING WIRE OR NYLON ROPE
SHOULD BE TIED TO STAKES IN AN
HOUR GLASS FORMATION (FRONT TO
BACK OF WATTLE "A", ACROSS TO
FRONT OF WATTLE "B", ACROSS TO
BACK AND BACK TO FRONT OF
WATTLE "A"). STAKES SHOULD THEN
BE DRIVEN IN UNTIL BAILING WIRE OR
NYLON ROPE IS SUFFICIENTLY SNUG
TO THE WATTLE.
W1 & W2 INSTALLATION NOTES:
1. THE LOCATION AND LENGTH OF WATTLE IS DEPENDENT ON THE CONDITIONS OF EACH SITE.
2. WATTLES SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES.
3. WATTLES SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR, OR COCONUT FIBER.
4. NOT FOR USE IN CONCENTRATED FLOW AREAS.
5. THE WATTLES SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF TWO (2) INCHES.
6. WATTLES SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
7. ON SLOPES, WATTLES SHOULD BE INSTALLED ON CONTOUR WITH A SLIGHT DOWNWARD ANGLE AT THE END OF THE ROW IN ORDER TO
PREVENT PONDING AT THE MID SECTION.
8. RUNNING LENGTHS OF WATTLES SHOULD BE ABUTTED FIRMLY TO ENSURE NO LEAKAGE AT THE ABUTMENTS.
9. SPACING - DOWNSLOPE:
VERTICAL SPACING FOR SLOPE INSTALLATIONS SHOULD BE DETERMINED BY SITE CONDITIONS. SLOPE GRADIENT AND SOIL TYPE ARE THE
MAIN FACTORS. A GOOD RULE OF THUMB IS:
1:1 SLOPES = 10 FEET APART
2:1 SLOPES = 20 FEET APART
3:1 SLOPES = 30 FEET APART
4:1 SLOPES = 40 FEET APART, ETC.
HOWEVER, ADJUSTMENTS MAY HAVE TO BE MADE FOR THE SOIL TYPE: FOR SOFT, LOAMY SOILS - ADJUST THE ROWS CLOSER
TOGETHER; FOR HARD, ROCKY SOILS - ADJUST THE ROWS FURTHER APART. A SECONDARY WATTLE PLACED BEHIND THE ABUTMENT OF TWO
WATTLES IS ENCOURAGED ON STEEP SLOPES OR WHERE JOINTS HAVE FAILED IN THE PAST.
10. STAKING: THE CITY RECOMMENDS USING WOOD STAKES TO SECURE THE WATTLES. 1/2" TO 5/8" REBAR IS ALSO ACCEPTABLE. BE SURE TO
USE A STAKE THAT IS LONG ENOUGH TO PROTRUDE SEVERAL INCHES ABOVE THE WATTLE: 18" IS A GOOD LENGTH FOR HARD, ROCKY SOIL.
FOR SOFT LOAMY SOIL USE A 24" STAKE.
4"-6" ABOVE WATTLE AFTER BAILING WIRE
OR NYLON ROPE IS ATTACHED. STAKES
NEED TO BE TAMPED UNTIL WIRE/ROPE IS
SNUG WITH WATTLE.
1"x 1" WOOD STAKES
18"-24"
ENDS OF ADJACENT WATTLES
SHALL BE TIGHTLY ABUTTED
TO PREVENT SEDIMENT BYPASS
W2 NOTE:
ONLY WATTLES MADE WITH COCONUT
FIBERS SHALL BE USED WHEN
INSTALLATION COMES IN CONTACT WITH A
WATER BODY.
SW
NOT TO SCALE
OUTLET PROTECTION
OP NOT TO SCALE
CONCRETE WASHOUT AREA
CWA NOT TO SCALE
ROCK SOCK
RS NOT TO SCALE
VEHICLE TRACKING CONTROL PAD
VTC NOT TO SCALE
SILT FENCE
SF
NOT TO SCALE
STRAW WATTLE (WATTLE DYKE)
SW
NOT TO SCALE
TURF REINFORCEMENT MAT
SCOURSTOP PADTRM
NOT TO SCALE
INLET PROTECTION
(AREA INLET) IP NOT TO SCALE
INLET PROTECTION
(CURB INLET)IP
NOT TO SCALE
EROSION CONTROL BLANKET
(SLOPE STABILIZATION)SS
NOT TO SCALE
SCOURSTOP MAT SCHEDULE
SMS
ER
O
S
I
O
N
C
O
N
T
R
O
L
D
E
T
A
I
L
S
10
N/A
N/A
C 304
SCOURSTOP SCHEDULE
Storm
Line
Mat Length
(ft)
Mat Width
(ft)
Quantity of
Mats
2 8 8 4
4 8 8 4
5 8 8 4
/ / / / / / / /
/ / / / / / / /
F.O.
X
X
XX
X
X
X
X
X
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
CO
R
D
O
V
A
R
O
A
D
DUFF DRIVE
N
O
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
CO
R
D
O
V
A
R
O
A
D
DUFF DRIVE
BUILDING
9
BUILDING
8
BUILDING
5
BUILDING 1
BUILDING
2
NORTH LIN
K
L
A
N
E
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
EXISTING 5' WALK
DOG PARK
RAIN GARDEN D
BUILDING
10
BUILDING 3
BUILDING
6
BUILDING
7
BUILDING
4
DETENTION
POND 2
DETENTION
POND 1
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
9' UTILITY EASEMENT
9' UTILITY EASEMENT
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
TRASH
ENCLOSURE
CL
U
B
H
O
U
S
E
FI
T
N
E
S
S
C
E
N
T
E
R
RAIN GARDEN B
RAIN
GARDEN A
RAIN
GARDEN C
RAIN GARDEN M
GARAGE
GA
R
A
G
E
GARAGE
GARAGE
GA
R
A
G
E
GARAGE
GARAGE
MA
I
N
T
E
N
A
N
C
E
SH
E
D
LEASING
CA
R
R
I
A
G
E
HO
U
S
E
2
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
CARRIAGE
HOUSE 1
NORTH LIN
K
L
A
N
E
WH
I
T
E
G
O
L
D
D
R
I
V
E
LANDSCAPE
WALL
PROPOSED
BARRICADE
PROPOSED
BARRICADE
CORDOVA ROAD PLAN & PROFILE
SEE SHEET 28-29
TRASH CORRAL (TYP.)
FOREBAY
4
4
4
2
6
6
4
4
4 4
4 4
2
4
2
2
2
2
2
2
8
8
2
2
1
2
2
2
1
2
2
2
2
22
2
2
2
2
4
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
5
5
5
2
2
12
2
2
2
2
2
4
4
4
2
2
4
2
2
22
2
2
2
2
20' HEAVY DUTY
CONCRETE APRON
FOREBAY
FOREBAY
FOREBAY
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.STREET SIGNS AND PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS
STANDARDS (LCUASS), CURRENT EDITION. FOR SITUATIONS WHERE LCUASS DOES
NOT DEFINE A PREFERRED MARKING/SIGN STYLE, CONTRACTOR SHALL DEFER TO
MUTCD STANDARDS, CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS REQUIREMENTS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
11.CONCRETE PANS SHALL BE 4" THICK IN LANDSCAPED AREAS AND 6" THICK IN ALL
PAVED AREAS WITH TRAFFIC.
12.SIGN LOCATIONS SHOWN ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT FOR
VISIBILITY OR OTHER FACTORS.
13.SEE SHEET C 808 FOR FIRE LANE SIGNAGE DETAIL NO. 1418.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
X' CURB CUT
18" VERTICAL INFLOW CURB & GUTTER 1
18" VERTICAL OUTFALL CURB & GUTTER 2
30" VERTICAL INFLOW CURB & GUTTER 3
30" VERTICAL OUTFALL CURB & GUTTER 4
CURB TRANSITION
FLUSH CURB
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
CONCRETE (PRIVATE FLATWORK)
CONCRETE PAVING (HEAVY DUTY)
X' SIDEWALK CHASE
HEAVY DUTY PAVING
DETAIL 1, SHEET 67
LIGHT DUTY PAVING
DETAIL 2, SHEET 67
X
TR
FL
X
X' CONCRETE CROSS-PAN X
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
P
D
18" FLAT CURB 5
LEGEND
SITE SIGN LEGEND
NOTES
FENCE
STAMPED CONCRETE (HEAVY DUTY)
4B
4" CONCRETE PAN (LANDSCAPING)
6" CONCRETE PAN (PAVED AREAS)
ARTERIAL
PAVING
DCDECORATIVE
CROSSWALK
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5
OV
E
R
A
L
L
P
A
V
I
N
G
P
L
A
N
11
1" = 50'
N/A
C 400
N
O
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
R25'
R25'
R25'
R25'
R25'
R25'
R25'
R10'
R10'
R25'
R25'R51'
R25'
R10'
R10'
R25'
R38'
R3'
R25'
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
R51'
R51'
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
BUILDING
9
BUILDING
1
6' SIDEW
A
L
K
DOG PARK
BUILDING
10
TRASH
ENCLOSURE
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6' SIDEWAL
K
RAIN GARDEN B
GARAGE
GARAGE
CA
R
R
I
A
G
E
H
O
U
S
E
GARAGE
CA
R
R
I
A
G
E
H
O
U
S
E
CA
R
R
I
A
G
E
H
O
U
S
E
MA
I
N
T
E
N
A
N
C
E
SH
E
D
9' (TYP.)
17' (TYP.)
9' (TYP.)
9' (TYP.)
17' (TYP.)
23' (TYP.)
8' (TYP.)
23' (TYP.)
8' (TYP.)
26'
FL-FL
24'
FL-FL
20' E&BE
30' E&BE
30' E&BE
26' EAE
26' EAE
10' E&BE
26' EAE
26' EAE
26' EAE
24' EAE
30' E&BE
26' EAE8' (TYP.)
9'
5'
9' (TYP.)
19'
9' (TYP.)
19'
19' (TYP.)
9' (TYP.)
26'
FL-FL
30'
30'
9' (TYP.)
17'
(TYP.)
30' E&BE
26' PAE
2
6
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
PROPOSED TYPE III
BARRICADE
2
12'x6' TREE WELL (TYP.)
TRASH CORRAL (TYP.)
2
2
2
1
2
2
2
1
2
2
2
2
2 2
4
4
4
2
2
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
20' HEAVY DUTY
CONCRETE APRON
FOREBAY B
2
2
2
2
1
1
3R
3L
3R
3L
1
2
2
2
2
6
3R
3
WH
I
T
E
G
O
L
D
D
R
I
V
E
0.5
0.5
0.5
0.5
0.5
0.5
0.5
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
4
0
2
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 403
C 401
C 402
C 403
C 404
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.STREET SIGNS AND PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS
STANDARDS (LCUASS), CURRENT EDITION. FOR SITUATIONS WHERE LCUASS DOES
NOT DEFINE A PREFERRED MARKING/SIGN STYLE, CONTRACTOR SHALL DEFER TO
MUTCD STANDARDS, CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS REQUIREMENTS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
11.CONCRETE PANS SHALL BE 4" THICK IN LANDSCAPED AREAS AND 6" THICK IN ALL
PAVED AREAS WITH TRAFFIC.
12.SIGN LOCATIONS SHOWN ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT FOR
VISIBILITY OR OTHER FACTORS.
13.SEE SHEET C 808 FOR FIRE LANE SIGNAGE DETAIL NO. 1418.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
X' CURB CUT
18" VERTICAL INFLOW CURB & GUTTER 1
18" VERTICAL OUTFALL CURB & GUTTER 2
30" VERTICAL INFLOW CURB & GUTTER 3
30" VERTICAL OUTFALL CURB & GUTTER 4
CURB TRANSITION
FLUSH CURB
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
CONCRETE (PRIVATE FLATWORK)
CONCRETE PAVING (HEAVY DUTY)
X' SIDEWALK CHASE
HEAVY DUTY PAVING
DETAIL 1, SHEET 67
LIGHT DUTY PAVING
DETAIL 2, SHEET 67
X
TR
FL
X
X' CONCRETE CROSS-PAN X
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
P
D
18" FLAT CURB 5
LEGEND
SITE SIGN LEGEND
NOTES
FENCE
STAMPED CONCRETE (HEAVY DUTY)
4B
4" CONCRETE PAN (LANDSCAPING)
6" CONCRETE PAN (PAVED AREAS)
ARTERIAL
PAVING
DCDECORATIVE
CROSSWALK
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5 PA
V
I
N
G
P
L
A
N
12
1" = 30'
N/A
C 401
/ / / / / / / /
/
/
/
/
/
/
/
/
F.O.
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
CO
R
D
O
V
A
R
O
A
D
R25'
R25'
R25'
R12'
R12'
R12'
R25'
R25'R25'
R20'
R20'
EASEMENT
EXCLUSION
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWA
L
K
10' SIDEW
A
L
K
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
10' SIDEW
A
L
K
6' SIDEWA
L
K
6'
S
I
D
E
W
A
L
K
BUILDING
1
BUILDING
2
NORTH LIN
K
L
A
N
E
6' SIDEWA
L
K
BUILDING
3
DETENTION
POND 1
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
GARAGE
GA
R
A
G
E
9' (TYP.)
17' (TYP.)
9' (TYP.)
17' (TYP.)
9' (TYP.)
17' (TYP.)
9' (TYP.)
17'
9' (TYP.)
17' (TYP.)
23' (TYP.)
8' (TYP.)
23' (TYP.)
8' (TYP.)
26'
FL-FL
26'
FL-FL
26'
FL-FL
30' E&BE 26' EAE
& PAE
42' HALF ROW
52' FL-FL
26' EAE
35' E&BE
26' EAE
45' E&BE
26' EAE
26' EAE
26' EAE
30' E&BE
26' EAE
30' E&BE
45' E&BE
17'
(TYP.)
9'
9'
9' (TYP.)
23.5' E&BE
30'
FL-FL
26' EAE
30'
9' (TYP.)
17'
(TYP.)
26' PAE
4
4
4
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
LANDSCAPE
WALL
PROPOSED TYPE III
BARRICADE
12'x6' TREE
WELL (TYP.)8
TRASH CORRAL (TYP.)
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
1
1 1
1
2
20' X 25'
STRUCTURE
W/ TABLE
TEMPORARY
"NO CONSTRUCTION TRAFFIC"
SIGN
6
4
5
NORTH LI
N
K
L
A
N
E
CORDOVA ROAD STRIPING PLAN
SEE SHEET C 513
CO
R
D
O
V
A
R
O
A
D
(F
U
T
U
R
E
)
CORDOVA ROAD PLAN & PROFILE
SEE SHEETS C 510-C 511
0.5
0.5
0.5
0.5
0.5
0.5
0.5
HALF ROW VARIES
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
4
0
1
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 404
C 401
C 402
C 403
C 404
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.STREET SIGNS AND PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS
STANDARDS (LCUASS), CURRENT EDITION. FOR SITUATIONS WHERE LCUASS DOES
NOT DEFINE A PREFERRED MARKING/SIGN STYLE, CONTRACTOR SHALL DEFER TO
MUTCD STANDARDS, CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS REQUIREMENTS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
11.CONCRETE PANS SHALL BE 4" THICK IN LANDSCAPED AREAS AND 6" THICK IN ALL
PAVED AREAS WITH TRAFFIC.
12.SIGN LOCATIONS SHOWN ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT FOR
VISIBILITY OR OTHER FACTORS.
13.SEE SHEET C 808 FOR FIRE LANE SIGNAGE DETAIL NO. 1418.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
X' CURB CUT
18" VERTICAL INFLOW CURB & GUTTER 1
18" VERTICAL OUTFALL CURB & GUTTER 2
30" VERTICAL INFLOW CURB & GUTTER 3
30" VERTICAL OUTFALL CURB & GUTTER 4
CURB TRANSITION
FLUSH CURB
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
CONCRETE (PRIVATE FLATWORK)
CONCRETE PAVING (HEAVY DUTY)
X' SIDEWALK CHASE
HEAVY DUTY PAVING
DETAIL 1, SHEET 67
LIGHT DUTY PAVING
DETAIL 2, SHEET 67
X
TR
FL
X
X' CONCRETE CROSS-PAN X
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
P
D
18" FLAT CURB 5
LEGEND
SITE SIGN LEGEND
NOTES
FENCE
STAMPED CONCRETE (HEAVY DUTY)
4B
4" CONCRETE PAN (LANDSCAPING)
6" CONCRETE PAN (PAVED AREAS)
ARTERIAL
PAVING
DCDECORATIVE
CROSSWALK
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5 PA
V
I
N
G
P
L
A
N
13
1" = 30'
N/A
C 402
9' (TYP.)
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
R25'
R25'
R12'
R25'
R25'
R25'
R25'
R25'
R25'R25'
R25'R25'
R38'
R25'
R20'R20'
CA
R
R
I
A
G
E
H
O
U
S
E
R14'
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
6' SIDEWAL
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6' SIDEWA
L
K
BUILDING
8
BUILDING
5
EX
I
S
T
I
N
G
1
0
'
W
A
L
K
EXISTING 5' WALK
BUILDING
7
BUILDING
4
9' UTILITY EASEMENT
CLUBHOUSE
FI
T
N
E
S
S
C
E
N
T
E
R
6' SIDEWA
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWALK
RAIN
GARDEN A
RAIN GARDEN M
CA
R
R
I
A
G
E
H
O
U
S
E
CA
R
R
I
A
G
E
H
O
U
S
E
CA
R
R
I
A
G
E
H
O
U
S
E
CARRIAGE HOUSE
23' (TYP.)
8' (TYP.)
8' (TYP.)
23' (TYP.)
23' (TYP.)
9' (TYP.)
17' (TYP.)
19'
17' (TYP.)
9' (TYP.)
9' (TYP.)5'
17' (TYP.)
9' (TYP.)
17'
(TYP.)
9' (TYP.)
17' (TYP.)
9' (TYP.)
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
30' E&BE
26' EAE
24'
FL-FL
26' EAE
30' E&BE
30' E&BE
26' EAE
32' E&BE
26' EAE
26' EAE
30' E&BE
26' EAE
26' EAE
30' E&BE
30' E&BE
26' EAE
23' (TYP.)
8' (TYP.)
8' (TYP.)
5'
8'
7'
9' (TYP.)
9'
(TYP.)
9'
19'
19'
24' EAE
30'
30'
30'
17' (TYP.)
8' (TYP.)
6
4
EASEMENT
EXCLUSION
2
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
2
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
2
2
12'x6' TREE
WELL (TYP.)
LANDSCAPE
WALL
8
TRASH CORRAL (TYP.)
2
2
4
2
2
2
2
2
2
2
2
2
2
5
5
5
2
2
1
2
2
2
4
2
FOREBAY M
FOREBAY A
EASEMENT
EXCLUSION
TRASH CORRAL (TYP.)
2
2
22
1
1
1
1
2
3R
3L
3R
3L
3L
3R
LEASING
3L
3
WH
I
T
E
G
O
L
D
D
R
I
V
E
0.5
0.5 0.5
3
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
4
0
4
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 401
C 401
C 402
C 403
C 404
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.STREET SIGNS AND PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS
STANDARDS (LCUASS), CURRENT EDITION. FOR SITUATIONS WHERE LCUASS DOES
NOT DEFINE A PREFERRED MARKING/SIGN STYLE, CONTRACTOR SHALL DEFER TO
MUTCD STANDARDS, CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS REQUIREMENTS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
11.CONCRETE PANS SHALL BE 4" THICK IN LANDSCAPED AREAS AND 6" THICK IN ALL
PAVED AREAS WITH TRAFFIC.
12.SIGN LOCATIONS SHOWN ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT FOR
VISIBILITY OR OTHER FACTORS.
13.SEE SHEET C 808 FOR FIRE LANE SIGNAGE DETAIL NO. 1418.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
X' CURB CUT
18" VERTICAL INFLOW CURB & GUTTER 1
18" VERTICAL OUTFALL CURB & GUTTER 2
30" VERTICAL INFLOW CURB & GUTTER 3
30" VERTICAL OUTFALL CURB & GUTTER 4
CURB TRANSITION
FLUSH CURB
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
CONCRETE (PRIVATE FLATWORK)
CONCRETE PAVING (HEAVY DUTY)
X' SIDEWALK CHASE
HEAVY DUTY PAVING
DETAIL 1, SHEET 67
LIGHT DUTY PAVING
DETAIL 2, SHEET 67
X
TR
FL
X
X' CONCRETE CROSS-PAN X
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
P
D
18" FLAT CURB 5
LEGEND
SITE SIGN LEGEND
NOTES
FENCE
STAMPED CONCRETE (HEAVY DUTY)
4B
4" CONCRETE PAN (LANDSCAPING)
6" CONCRETE PAN (PAVED AREAS)
ARTERIAL
PAVING
DCDECORATIVE
CROSSWALK
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5 PA
V
I
N
G
P
L
A
N
14
1" = 30'
N/A
C 403
/ / / / / / / /
17'
(TYP.)
CO
R
D
O
V
A
R
O
A
D
DUFF DRIVE
26' EAE
17'
(TYP.)
R12'R12'
R25'R25'
R12'
R25'
R12'R12'
R12'R25'
R25'
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWA
L
K
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
BUILDING
5
RAIN GARDEN D
BUILDING
6
DETENTION
POND 2
9' UTILITY EASEMENT
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
6' SIDEWALK
RAIN GARDEN C
GA
R
A
G
E
GARAGE
17' (TYP.)
9' (TYP.)
17'
(TYP.)
9' (TYP.)
17'
(TYP.)
9' (TYP.)
9' (TYP.)
17' (TYP.)
17' (TYP.)
9' (TYP.)
9' (TYP.)
9' (TYP.)
17' (TYP.)
9' (TYP.)
19'
9' (TYP.)
17' (TYP.)
26'
FL-FL
26'
FL-FL
24'
FL-FL
26' EAE
30' E&BE
30' EAE
42' HALF ROW
52' FL-FL
26' EAE
17'
(TYP.)
5'
9'
19'
4
4 4
4 4
LANDSCAPE
WALL
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
4
2
2
2
CORDOVA ROAD PLAN & PROFILE
SEE SHEETS C 510-C 511
TRASH CORRAL (TYP.)
2
2
4
2
2
2
2
2
2
2
TRASH
CORRAL
(TYP.)FOREBAY C
2
2
C-CHANNEL
SEE SHEET C 805 FOR DETAILS
20' X 25'
STRUCTURE
W/ TABLE
TEMPORARY "NO
CONSTRUCTION TRAFFIC" SIGN
4
5
CORDOVA ROAD STRIPING PLAN
SEE SHEET C 513
0.5 0.5
HALF ROW VARIES
FOREBAY D
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
4
0
3
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 402
C 401
C 402
C 403
C 404
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.STREET SIGNS AND PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS
STANDARDS (LCUASS), CURRENT EDITION. FOR SITUATIONS WHERE LCUASS DOES
NOT DEFINE A PREFERRED MARKING/SIGN STYLE, CONTRACTOR SHALL DEFER TO
MUTCD STANDARDS, CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS REQUIREMENTS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
11.CONCRETE PANS SHALL BE 4" THICK IN LANDSCAPED AREAS AND 6" THICK IN ALL
PAVED AREAS WITH TRAFFIC.
12.SIGN LOCATIONS SHOWN ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT FOR
VISIBILITY OR OTHER FACTORS.
13.SEE SHEET C 808 FOR FIRE LANE SIGNAGE DETAIL NO. 1418.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
X' CURB CUT
18" VERTICAL INFLOW CURB & GUTTER 1
18" VERTICAL OUTFALL CURB & GUTTER 2
30" VERTICAL INFLOW CURB & GUTTER 3
30" VERTICAL OUTFALL CURB & GUTTER 4
CURB TRANSITION
FLUSH CURB
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
CONCRETE (PRIVATE FLATWORK)
CONCRETE PAVING (HEAVY DUTY)
X' SIDEWALK CHASE
HEAVY DUTY PAVING
DETAIL 1, SHEET 67
LIGHT DUTY PAVING
DETAIL 2, SHEET 67
X
TR
FL
X
X' CONCRETE CROSS-PAN X
PARALLEL ACCESS RAMP
DIRECTIONAL ACCESS RAMP
P
D
18" FLAT CURB 5
LEGEND
SITE SIGN LEGEND
NOTES
FENCE
STAMPED CONCRETE (HEAVY DUTY)
4B
4" CONCRETE PAN (LANDSCAPING)
6" CONCRETE PAN (PAVED AREAS)
ARTERIAL
PAVING
DCDECORATIVE
CROSSWALK
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5 PA
V
I
N
G
P
L
A
N
15
1" = 30'
N/A
C 404
U
D
UD
UD
UD
UD
UD
UDUD
UD
U
D
UD
UD
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
TEST
STA
VAUL
T
ELEC
TEST
STA
V.P.
VAUL
T
ELEC
ELEC
ELEC
F.O.
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
XX
X
X
X
X
X
/ / / / / / / /
/ / / / / / / /
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
CO
R
D
O
V
A
R
O
A
D
LINK LANE
EASEMENT EXCLUSION (TYP.)
E
E
E
FFE=47.83
FFE=48.21
FFE=48.33
FFE=47.58
FFE=46.93
FFE=45.91
FFE=45.38
FFE=45.19
FFE=46.30
FFE=45.38
FFE=47.51
FFE=48.51
FFE=47.51
FF
E
=
4
4
.
2
2
FF
E
=
4
4
.
3
0
FFE=44.26 FF
E
=
4
3
.
7
1
FF
E
=
4
6
.
1
9
FF
E
=
4
7
.
8
2
FFE=46.60
BUILDING
10
BUILDING
9
BUILDING
8
BUILDING
7
BUILDING
5
BUILDING
4
BUILDING
1
BUILDING
2
BUILDING
3
DETENTION
POND 2
DETENTION
POND 1
BUILDING
6
RAIN GARDEN D
RAIN GARDEN B
RAIN
GARDEN A
RAIN GARDEN C
RAIN GARDEN M
CLUBHOUSE
GARAGE
GA
R
A
G
E
GA
R
A
G
E
GA
R
A
G
E
GA
R
A
G
E
GARAGE
GA
R
A
G
E
FITNESS
CENTER
LEASING
6' SIDEWAL
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWA
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWAL
K
6' SIDEWAL
K
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWA
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWALK
6' SIDEWAL
K
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
12
'
S
I
D
E
W
A
L
K
12
'
S
I
D
E
W
A
L
K
12
'
S
I
D
E
W
A
L
K
12
'
S
I
D
E
W
A
L
K
12
'
S
I
D
E
W
A
L
K
12' SIDEWA
L
K
12' SIDEW
A
L
K
12
'
S
I
D
E
W
A
L
K
12
'
S
I
D
E
W
A
L
K
E E E E E
E
E
E
E E E
E
E
E
E
E
P
P
P
P
P P PP
P
P
P
G
G
G
G
G
EX
I
S
T
I
N
G
1
2
'
T
R
A
I
L
P
P
PCA
R
R
I
A
G
E
HO
U
S
E
2
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
CARRIAGE
HOUSE 1
FFE=48.21
FFE=48.33
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
KEYMAP
NOT TO SCALE
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
AD
A
R
O
U
T
I
N
G
P
L
A
N
16
1" = 50'
N/A
C 410
EASEMENTS
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER FORT COLLINS STANDARDS (LCUASS),
CURRENT EDITION.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN STREET STANDARDS STREET
REPAIR GUIDELINES.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO LARIMER COUNTY URBAN STREET STANDARDS REQUIREMENTS AT
THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK, UNLESS OTHERWISE NOTED
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
8.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
9.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
10.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL-WEATHER DRIVING SURFACE
CAPABLE OF SUPPORTING 40 TONS.
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
ADA ACCESSIBILITY PATH
E
LEGEND
NOTES
FENCE
ADA ACCESSIBILITY BUILDING ENTRANCE
ADA ACCESSIBILITY PARKING
ADA ACCESSIBILITY GARAGE
P
G
U
D
UD
UD
UD
UD
UD
UDUD
UD
U
D
UD
UD
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
TEST
STA
VAUL
T
ELEC
TEST
STA
V.P.
ST
VAUL
T
ELEC
ELEC
ELEC
F.O.
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
XX
X
X
X
X
X
STST
ST
/ / / / / / / /
/ / / / / / / /
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
CO
R
D
O
V
A
R
O
A
D
LINK LANE
CONNECT TO
EXISTING
STORM DRAIN
EXISTING
STORM DRAIN
PROPOSED
POND OUTLET
STRUCTURE
PROPOSED
POND OUTLET
STRUCTURE
BUILDING
10
BUILDING
9
BUILDING
8
BUILDING
7
BUILDING
5
BUILDING
4
BUILDING
1
BUILDING
2
BUILDING
3
DETENTION
POND 2
DETENTION
POND 1
EXISTING
STORM DRAIN
BUILDING
6
FFE=47.83
FFE=48.21
FFE=48.33
FFE=47.58 FFE=46.93
FFE=45.91
FFE=45.38
FFE=45.19
FFE=46.30
FFE=45.38
FFE=47.51
BLANKET DRAINAGE
& UTILITY EASEMENT
RAIN GARDEN D
RAIN GARDEN B
RAIN
GARDEN A
RAIN GARDEN C
RAIN GARDEN M
CA
R
R
I
A
G
E
HO
U
S
E
2
CLUBHOUSE
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
FFE=48.51
GARAGE
GA
R
A
G
E
GARAGE
GARAGE
GA
R
A
G
E
GARAGE
GARAGE
PROPOSED LANDSCAPE WALL
PROPOSED
LANDSCAPE WALL
PROPOSED 2' CONCRETE PAN
PROPOSED 2' CONCRETE PAN
PROPOSED 2' CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
20' E&BE
30' E&BE
26'
FL-FL
10' E&BE
26' EAE
26' EAE
26' EAE
26' EAE
33.5' E&BE
26' EAE
26' EAE
26' EAE
35' E&BE26' EAE
30' E&BE 26' EAE
26' EAE
30' E&BE
30' EAE
30' E&BE
30' E&BE
45' E&BE
23.5' E&BE
30'
FL-FL
EASEMENT EXCLUSION (TYP.)
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
FITNESS
CENTER
CARRIAGE
HOUSE 1
26'
FL-FL
26' EAE
30' E&BE
30' E&BE
26' PAE
30'
E&BE
26'
FL-FL
26' EAE
26' EAE
FF
E
=
4
8
.
4
6
FF
E
=
4
8
.
7
1
FF
E
=
4
8
.
0
0
FF
E
=
4
8
.
0
9
FF
E
=
4
8
.
7
1
FF
E
=
4
8
.
4
1
FF
E
=
4
7
.
7
9
FFE=47.95
FFE=46.52
FFE=47.24
FFE=47.36
FFE=44.47
FF
E
=
4
4
.
2
4
FFE=44.30 FF
E
=
4
3
.
6
7
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 3-3
SEE SHEET C 632
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
STORM DRAIN 4
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
STORM DRAIN 6-2
SEE SHEET C 634
STORM DRAIN 3
SEE SHEET C 631
FFE=48.33
FFE=48.21
FFE=47.83
FFE=45.38
NORTH LIN
K
L
A
N
E
WH
I
T
E
G
O
L
D
D
R
I
V
E
PROPOSED 8' CROSSPAN
PROPOSED 8' CROSSPAN
PROPOSED 8' CROSSPAN
PVC SIDEWALK CULVERT (TYP.)PVC SIDEWALK CULVERT (TYP.)
STORMTECH CHAMBERS
SEE SHEETS C 510, C 634, & C 807
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
KEYMAP
NOT TO SCALE
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
OV
E
R
A
L
L
G
R
A
D
I
N
G
P
L
A
N
17
1" = 50'
N/A
C 500
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DOG PARK
1.
1
%
0.0%
0.
6
%
0.
6
%
30' EAE
27' EAE
10' E&BE
26'
FL-FL
GARAGE
GARAGE
TRASH
ENCLOSURE
30' E&BE
CA
R
R
I
A
G
E
H
O
U
S
E
8
MA
I
N
T
E
N
A
N
C
E
SH
E
D
FF
E
=
4
7
.
1
9
FF
E
=
4
7
.
8
2
FF
E
=
4
8
.
7
0
FF
E
=
4
7
.
6
6
GARAGE
47
.
1
3
47.78
4
7
.
0
2
47.66
46.9
4
46.82
45.09
47.78
4
7
.
7
8
4
7
.
6
4
44.08
4
5
.
2
7
46.38
4
5
.
6
1
47.66
47.89
47.94
48.37
47.14
4
5
.
2
5
4
5
.
5
7
4
6
.
6
3
45.8946.26
4
6
.
3
4
46.65
46.67
45.89
45.87
4
5
.
8
1
45.67
46.38
47.0
8
46.36
46.44
4
7
.
3
8
4
7
.
7
2
4
7
.
6
8
47.32
47.32
4
6
.
5
7
4
8
.
7
0
48
.
7
0
48.40
48.
6
3
4
8
.
4
7
48.62
4
8
.
4
7
48.87
48.95 48.85 48.51
48.56
48.
6
2
4
7
.
7
8
48.31
4
8
.
4
8
48.29
4
8
.
9
5
48.74
4
8
.
2
1
48.1
4
48.3
0
48.52
48.70
48.70
48.70
4
8
.
7
0
4
8
.
7
0
48.7
0
48.7
0
47.66
47.66
47.
6
6
4
7
.
1
3
4
8
.
6
1
47.13
47.13
47.13
4
7
.
1
9
46.91
47.36
46.36
4
7
.
1
5
47
.
1
6
47.14
46
.
8
6
4
7
.
5
1
47.39
45.94
4
7
.
9
6
4
7
.
7
0
47
.
6
4
4
7
.
8
1
47.70
4
6
.
9
8
4
7
.
0
6
47.54
4
8
.
1
6
47.80
47.90
4
4
.
9
7
4
4
.
9
7
4
4
.
2
4
47.84
LL
LL
LL
46.57
4
4
.
0
0
45.00
45.00
6.1%
5
.
4
%
2.2%
49.13
4
9
.
1
3
4
7
.
1
3
47.86
47.47
4
6
.
8
6
46
.
7
4
4
7
.
7
2
47.
4
3
47.68
49.0349.03
4:1
EXISTING
LANDSCAPE WALL
PROPOSED 2'
CONCRETE PAN
PROPOSED
4' CROSSPAN
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
LL
LL
LL
LL
LL
4
6
.
6
7
4
6
.
6
7
2.0%
2.0%
0.
5
%
0.
7
%
0.
1
%
3.
5
%
1.
9
%
2.
0
%
2.0%
2.0%
2.3%
2.1%
0.1%
44.00
FFE=47.19
FFE=47.13
4
8
.
3
7
47.33
47.33
4
7
.
3
3
47.54
4
8
.
9
5
48.95
4
8
.
7
0
48.70
FFE=46.94
FFE=46.6
9
4
6
.
0
0
46.
8
6
46
.
6
1
46
.
6
1
46.
3
6
FF
E
=
4
6
.
1
9
FF
E
=
4
7
.
0
2
FF
E
=
4
6
.
0
2
FF
E
=
4
7
.
3
6
FF
E
=
4
6
.
3
6
46.
8
6
46.
6
9
46.
8
6
47.
0
2
47.
0
3
47.
3
2
47.
4
9
47.
4
9
47.
6
5
46.90
46.74
FF
E
=
4
7
.
0
7
FF
E
=
4
7
.
6
5
FF
E
=
4
6
.
9
0
FF
E
=
4
7
.
9
9
FF
E
=
4
7
.
2
4
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
2
MATCH LINE - SEE SHEET C 504
GR
A
D
I
N
G
P
L
A
N
18
1" = 20'
N/A
C 501
UD
UD
UD
UD
UD
/ / / / / / / /
FFE=47.83
FFE=45.38
0.
6
%
2.1%
2.0%
1.2%
0.6%
0.
9
%
0.6%
1.
9
%
0.
6
%
1.1%
26' EAE
26' EAE
26' EAE
26' EAE
30' E&BE
30' E&BE
45' E&BE
30' E&BE
26'
FL-FL
GARAGE
GARAGE
GARAGE
10
'
S
I
D
E
W
A
L
K
10' SIDEW
A
L
K
10
'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWA
L
K
RAIN GARDEN B
BUILDING
10
BUILDING
3
26' EAE
& PAE
26' PAE
FF
E
=
4
7
.
1
9
GARAGE
0.6%
0.5%
0.6%
47.16
4
7
.
1
6
45.63
4
6
.
0
0
46.46
4
6
.
5
1
4
6
.
6
8
44.93
4
5
.
4
6
45.63
4
3
.
8
7
44
.
6
7
4
5
.
2
1
44.62
45.06
4
5
.
6
1
4
4
.
6
6
44.77
45.
3
3
45.05
45.61
45.50
45.43
4
5
.
6
7
45.57
46.90
46.90
46.57
46.08
45.69
46.07
45.98
4
6
.
0
1
45
.
7
4
46.40
46.2346.9
0
4
6
.
5
7
4
4
.
2
2
4
4
.
3
1
45.12
45.36
44.70
4
4
.
3
3
44.84
4
4
.
5
3
4
4
.
4
4
43.84
43.56
44.40
44.12
4
3
.
9
8
43.96
44.1
5
4
4
.
3
0
4
4
.
3
0
4
4
.
4
3
44.46
4
4
.
8
7
44.42
4
4
.
5
6
44.17
4
4
.
3
9
4
4
.
4
9
4
4
.
7
7
4
3
.
5
8
4
3
.
3
7
43.57
43.39
43.87
4
6
.
3
6
4
7
.
5
2
4
7
.
4
8
4
5
.
4
2
45
.
3
8
44.61
44.73
4
4
.
9
4
4
5
.
1
8
45
.
2
8
4
5
.
6
8
46.07
47
.
1
6
47.16
47.07
47.07
47.07
47.07
47.10
4
7
.
1
0
47.16
47.16
46.13
46.17
45.83
47.16
47.16
4
7
.
1
6
4
7
.
1
6
45.66
45.70
45.76
45.88
45.
9
0
45.
8
6
47.16
47.16
47.16
47.16
46.
1
9
46.
1
7
47.
1
6
47.
1
6
47.16
4
7
.
1
6
47.16
4
7
.
1
6
46.
1
1
4
6
.
1
1
46.00
45.5
0
4
5
.
4
8
45
.
6
3
45.63
4
5
.
6
3
45.63
4
5
.
1
2
45.12
44
.
3
5
44.43
44.22
44.18
44.10
43.90
43.50
44.57
44.53
44.47
44.46
4
5
.
1
5
4
5
.
1
2
4
4
.
7
1
45.48
45.18
45.06
4
4
.
7
1
44.71
44.71
4
4
.
7
1
44.71
44.71
4
4
.
7
1
4
4
.
7
1
44.71
4
4
.
7
1
44.71
4
4
.
7
1
45.45
44.41
44.85
44.41
44.53
4
4
.
8
8
44.41
44.56
4
4
.
7
1
44.71
44.68
4
4
.
6
8
44.71
44.71
44.71
44.68
4
4
.
6
8
44.71
4
4
.
7
1
44.68
4
4
.
6
8
44.714
4
.
0
3
44.1
3
44
.
7
3
4
4
.
7
4
4
4
.
8
2
4
4
.
9
4
46.2
546.2
2
46
.
1
8
46
.
0
8
46.0
0
46.00
45.88
45.99
46.17
46.13
46
.
2
1
46
.
0
2
4
6
.
0
6
44
.
7
0
4
5
.
2
1
44.46
44.45
45.03
45.20
45.29
4
5
.
3
7
LL
LL
45.34
LL
LL
45.88
LL
LL
LL
LL
LL
LL
4
5
.
0
7
4
5
.
1
5
47.16
4
7
.
1
6
47.16
4
7
.
1
6
47.16
4
7
.
1
6
4
4
.
0
0
45.20
45.82
45.00
45.50
4
5
.
4
0
44.0
0
4
4
.
7
1
44
.
0
7
4
4
.
0
7
44.0
7
4
4
.
0
7
43.88
44.0144.18
44.13
4
4
.
1
0
44.09
4
3
.
9
8
4
4
.
1
2
43.62
43.73
43.46
4
2
.
8
2
43.37
44.75
4
3
.
3
7
4
3
.
9
8
44.41 43.37
4
2
.
8
7
46.49
46.49
46.54
46.57
46.62
46.63 47.24
46.17
46.03
46.43
46.5
7
46.42 46.56
46.46
45.99
46.11
4
5
.
0
0
44.95
LL
4
4
.
9
1
44.80
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
44.76
PROPOSED STORM DRAIN
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
PROPOSED
4' CROSSPAN
STORM DRAIN 6
SEE SHEET C 634
LL
LL
LL
1.
6
%
2.
0
%
0.
6
%
0.
6
%
0.
2
%
0.
1
%
0.
2
%
0.
2
%
0.
6
%
0.
6
%
2.
0
%
0.
6
%
2.
0
%
2.
0
%
2.
0
%
2.
0
%
0.
6
%
2.
0
%
0.6%
2.0%
0.5%
2.0%
1.9%
2.0%
0.6%
0.6%
0.3%
3.0%
2.0%
0.5%
2.
0
%
0.1%
2.0%
2.0%
2.0%
1.8%
1.8%
45.00
4
5
.
1
3
44.98
44.00
45.17
45.80
45.00
44.00
4
5
.
0
0
45.00
45.00
43.26
FFE=46.94
FFE=46.69
FFE=46.47
46.
6
1
46
.
3
6
46
.
3
6
46
.
1
1
FF
E
=
4
6
.
1
9
FF
E
=
4
7
.
0
2
FF
E
=
4
6
.
0
2
45.69
45.86
45.86
46.03
46.03
FF
E
=
4
7
.
3
6
FF
E
=
4
6
.
3
6
46.90
46.74
46.74
46.57
FF
E
=
4
7
.
0
7
FF
E
=
4
7
.
6
5
FF
E
=
4
6
.
9
0
FF
E
=
4
7
.
2
4
FFE=43.60
FFE=44.24
FFE=44.41
FFE=43.7
6FFE=44.57
FFE=43.93
43.
2
6
43.
4
3
43.
4
3
43.
6
0
43.
6
0
43
.
8
1
LL
44
.
1
4
5.6%
4
4
.
8
3
44.00
4
4
.
0
0
25
.
0
%
25.0%
44.40
44.24
43.80
43.68
43.54
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
1
MATCH LINE - SEE SHEET C 505
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
19
1" = 20'
N/A
C 502
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
3
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
U
D
U
D
UD
UD
UD
F.O.
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
/ / / / / / / /
/ / / / / / / /
/
/
/
/
/
/
/
/
LINK LANE
DETENTION
POND 1
0.6%
0.6%
0.
6
%
2.0%
0.6%
0.
6
%
0.6%
0.
5
%
1.
4
%
0.6%
26' EAE
26' EAE
33.5' E&BE
30' E&BE
26'
FL-FL
42' HALF ROW
52' FL-FL
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
GARAGE
GA
R
A
G
E
10' SIDEW
A
L
K
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
26' EAE
& PAE
26' PAE
CO
R
D
O
V
A
R
O
A
D
FFE=44.07
FF
E
=
4
3
.
5
4
1.9%
0.6%
0.
5
%
0.
5
%
0.
5
%
0.
5
%
44.71
44.70
4
4
.
7
4
43.20
43.44
43.58
43.85
43.36
44.37
42
.
8
1
42.32
42.27
4
1
.
1
6
42.48
41.90
41.21
4
1
.
8
5
3
8
.
0
8
43.7
2
4
2
.
5
8
4
2
.
8
4
4
3
.
1
8
4
3
.
1
0
43.10
42.98
42.
9
4
4
2
.
3
3
42.18
4
2
.
2
2
4
2
.
1
9
4
2
.
8
8
4
2
.
7
9
43.03
42.88
42.69
42.73
42.77
42.87
43
.
4
6
43.3
7
43
.
4
5
43
.
4
2
43.32
4
3
.
0
3
4
3
.
1
8
4
3
.
6
1
43.10
42.85
42.48
42.55
43.54
43.36
4
3
.
2
6
43.00
42.97
42.17
43.13
43.15
43.18
43.33
43.45
43.59
4
3
.
6
2
43
.
5
9
4
3
.
4
7
43.38
43.41
4
4
.
7
1
44.71
44.71
4
4
.
7
1
44.68
4
4
.
6
8
44.71
44.71
4
4
.
7
1
42.74
42.
7
8
42.78
42.12
43.27
42.66
42.66
44.03
43
.
9
4
42.5
2
42.69
41.96
42.57
42.27
42.40
42.48
4
2
.
4
0
4
2
.
5
9
42
.
7
3
43.0
2
4
2
.
9
0
4
2
.
2
9
42.80
42.76
4
1
.
7
1
41.59
40.8441.09
4
1
.
8
3
41.79
4
1
.
6
5
42.09
41.9
6
42
.
0
1
42.15
41.4
7
4
1
.
3
4
4
1
.
8
4
43.82
43
.
9
0
42
.
6
542.7
7
41.5
8
4
1
.
5
8
41.58
41.5
8
38.00
LL
LL
43.57
LL
LL
LL
LL
43.37
4
3
.
3
0
LL
43.90
44
.
0
7
4
4
.
0
7
4
3
.
7
6
4
4
.
3
5
42.87
43.62
38.3
8
42.31
42.73
42.67
R
R
R
5:1
7:
1
6:1
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
STORM DRAIN 4
SEE SHEET C 630
STORM DRAIN 8
SEE SHEET C 634
STORMTECH CHAMBERS
SEE SHEETS C 634 & C 807
LL
4
2
.
8
9
42
.
9
3
0.
6
%
0.
8
%
0.
4
%
1.
8
%
2.
0
%
1.
2
%
0.
5
%
0.
5
%
0.6%
8.5%
2.0%
2.0%
2.0%
2.0%
5.0%
1.3%
0.
8
%
2.0%
0.
6
%
4
3
.
1
6
42.90
43.69
44.09
HALF ROW VARIES
FF
E
=
4
3
.
7
1
43.
5
4
43.
3
8
43.
3
8
43.
2
1
43.
2
1
FFE=43.43
FFE=43.6
0
FFE=44.24
43.
1
0
43.
2
6
43.
2
6
43.
4
3
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
2
MATCH LINE - SEE SHEET C 506
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
20
1" = 20'
N/A
C 503
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
NO
R
T
H
LE
M
A
Y
AV
E
N
U
E
FFE=48.21
FFE=48.33
3.1
%
2.0%
0.8%
0.
6
%
0.
6
%
0.6%
2.6%
0.
5
%
0.6%
3.3%
0.
6
%
2.1%
0.
6
%
0.
6
%
26' EAE
26' EAE
26' EAE
26' EAE
30' E&BE
30' E&BE
30' E&BE
24'
FL-FL
24'
FL-FL
FITNESS CENTER
CA
R
R
I
A
G
E
H
O
U
S
E
4
CA
R
R
I
A
G
E
H
O
U
S
E
5
CA
R
R
I
A
G
E
H
O
U
S
E
6
6' SIDEWAL
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
BUILDING
9
BUILDING
8
CA
R
R
I
A
G
E
HO
U
S
E
7
47.54
47.22
4
7
.
5
7
48.39
47.03
46.92
46.91
4
7
.
1
7
47.01
4
7
.
0
1
48.12
48
.
1
2
47.02
48
.
0
1
4
7
.
1
5
48.00
47.91
4
8
.
9
5
4
6
.
8
2
46
.
8
0
4
2
.
9
8
4
5
.
5
9
45.7345.73
47.96
48.02
42
.
6
4
46.89
4
8
.
9
5
48.19
46.95
4
7
.
4
4
4
7
.
1
4
4
7
.
2
2
47.10
47.57
47.50
47.17
4
7
.
4
7
47.37
47.23
4
6
.
8
6
4
6
.
8
9
46.90
46.90
47.93
46.9
0
48.95
48.95
48.
9
5
48.95
48.63
48.33
48.62
48.
3
4
48.
4
9
47
.
8
9
47.85
47.91
47.
9
1
48.2
5
47
.
9
3
48.3
3
47.33
4
7
.
3
3
48.23
48.33
47.55
4
7
.
4
2
47.05
4
7
.
3
3
47.08
47.08
4
8
.
7
2
48.65
48.
3
2
47.23
48.25
48.25
48.12
47.68
47.
6
0
47.7
8
48.05
4
8
.
2
5
48.25
4
8
.
2
5
4
8
.
2
5
4
8
.
2
5
48.95
48.91
4
7
.
2
8
47.05
47.4
7
47.05
4
7
.
3
0
47.30
47.55
4
7
.
5
5
47.99
47.94
4
7
.
7
0
4
7
.
7
5
4
7
.
5
5
4
7
.
5
5
47.45
47.5
4
47.51
4
7
.
5
5
47.55
47.54
4
7
.
5
4
47.62
47.55
4
7
.
5
4
47.54
47.51
47
.
5
4
47.51
47.54
47.
5
4
4
7
.
5
1
4
7
.
6
6
4
7
.
6
6
4
7
.
6
6
47.66
46.94
47.65
47.66
47.66
47.66
47.66
47.66 4
7
.
6
6
47
.
6
6
47.6
6
47.6
6
47.66
47.66
4
7
.
6
6
4
6
.
9
0
4
6
.
7
3
46.98
48.00
4
7
.
8
2
4
7
.
8
7
4
8
.
1
7
48.7
6
48
.
4
6
48.3
3
48.49
48
.
6
2
48.25
48.02
47.63
48.04
47.94
47.
9
6
47.
9
4
47.77
47.82
48.04
47.45
47.29
4
7
.
3
4
47.54
47.69
47.50
4
7
.
8
2
4
6
.
0
2
46.25
46.66
46.61
46.00
47.85
47.77
4
7
.
5
2
4
7
.
4
8
4
6
.
6
2
4
6
.
9
8
4
7
.
4
2
4
8
.
0
4
48
.
0
6
47.4
0
47
.
9
1
47.95
48.04
4
8
.
0
0
46.75
46.16
46.
0
7
4
6
.
1
1
46
.
1
4
48.43
48.43
47.96
47.59
47.36
47.8
3
48.51
48.5148.32
4
8
.
1
1
48.01
47.84
47.4
1
46
.
8
8
4
6
.
8
5
4
7
.
3
0
47.2246.7646.7947.32
48.66
48.57
48
.
6
6
48
.
6
3
48.
6
0
48.
7
6
4
8
.
4
1
48.3
1
48.
8
9
48.78
45.83
45.8
3
46
.
9
6
46.
9
5
4
7
.
7
4
47.7
7
47
.
8
4
4
7
.
8
7
48
.
3
3
4
7
.
4
8
47.4
6
47
.
3
6
47.3
2
46.79
46.7
5
46.
3
6
47
.
2
4
47
.
2
0
46.79
46.75
4
6
.
2
0
46.32
45
.
8
2
4
5
.
9
1
47.62
47.
6
2
47.49
4
7
.
4
9
46.99
46.
9
8
47.47
47.52
47.5
0
46
.
5
9
47.36
47.
4
4
4
3
.
1
4
4
7
.
3
8
47
.
3
1
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
LL
47.62
47.
6
2
48.
0
0
4
7
.
5
5
0.3%
47.6
2
4
6
.
9
4
4
7
.
1
1
4
7
.
0
7
4
7
.
0
4
4
7
.
0
2
47.01
46.66
46.55
46.38
48.5
1
48
.
5
1
4
7
.
5
2
4
7
.
2
5
47.52
45.73
45.73
47.32
46.1
1
R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RR
R
5:1
5:
1
4:1
4:1
EXISTING
STORM
DRAIN
PROPOSED
STORM DRAIN
EASEMENT
EXCLUSIONEA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 7
SEE SHEET C 630
2.0%
2.0%
4.7%
5.0%
2.0%
2.0%
2.0%
0.2%
0.9%
2.0%
0.8%
0.8%
0.3%
2.0%
2.0%
2.0%
0.6%
1.1%
1.9%1.
6
%
2.
0
%
2.
0
%
0.
6
%
0.
6
%
0.
6
%
0.
6
%
0.
6
%
0.
6
%
1.
6
%
2.
0
%
0.
1
%
0.
3
%
0.
8
%
0.
1
%
0.
5
%
0.
5
%
46.9
0
47.66
46.
5
5
47.66
4
6
.
8
4
2.
0
%
2.
2
%
0.7%
2.
3
%
1.
6
%
0.
1
%
2.9%
3.0%
FF
E
=
4
8
.
9
5
FF
E
=
4
8
.
2
5
FF
E
=
4
8
.
3
3
FF
E
=
4
8
.
9
5
48.2
8
48.57
48.36
48.62
0.
6
%
3.1%
48.32
48.6
2
48.95
48.33
48
.
3
3
47.
9
7
48.38
48.47
48.49
48.52
48.33
48.33
48.25
48.25
48.2
5
48.
9
548.9
5
4
8
.
9
5
48.3
348.
3
3
45.96
47.
6
5
FF
E
=
4
7
.
9
9
FF
E
=
4
7
.
2
4
FFE=48.51
46.41
46.53
48.3
4
47.
5
2
4
8
.
3
4
47.84
2.0%
2.
0
%
2.0%
2.0%
47.22
47.14
4
7
.
1
7
47.52
47.34
47.25
LL
47.1
6
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
5
MATCH LINE - SEE SHEET C 501
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
21
1" = 20'
N/A
C 504
MATCH LINE - SEE SHEET C 507
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD
UD
UD
UD
UD
UD
UD
FFE=46.30
FFE=45.38
3.
9
%
0.
6
%
0.
6
%
2.1%
0.
7
%
0.6%
1.1%
1.9%
0.1%
0.
6
%
0.
6
%
0.6%
0.6%
1.
3
%
0.
6
%
2.7%
0.2%
0.6%
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
20' E&BE
30' E&BE
30' E&BE
30' E&BE
45' E&BE
26'
FL-FL
26'
FL-FL
26'
FL-FL
24'
FL-FL
GARAGE
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWA
L
K
6' SIDEWA
L
K
6' SIDEWALK
6' SIDEWAL
K
RAIN GARDEN M
BUILDING
1
BUILDING
6
FFE=45.91
BUILDING
4
2.0%
0.6%
2.6%
1.7%
1.9%
47.1
6
47.16
45.
6
3
47.66
45.25
4
5
.
2
5
44.72
4
4
.
7
2
44.5
2
44.52
46.68
46.92
46.91
46.13
4
4
.
7
5
45.53
45.21
45.63
44.98
4
4
.
9
8
43.65
43.29
43.82
43.98
4
4
.
2
7
46.15
45.31
44
.
7
3
4
4
.
8
8
4
5
.
5
1
44
.
6
0
45.0
9
4
6
.
8
4
42.54
44.04
43
.
1
2
4
2
.
4
5
43.13
4
4
.
2
3
44.02
45
.
6
3
45.80
43.39
4
3
.
4
7
43.75
4
4
.
4
1
44.57
45.04
4
6
.
8
9
46.90
46.90
46.40
46.2346.9
0
47.5
4
47.51
47.54
47.54
4
7
.
5
5
4
7
.
5
4
47.55
4
7
.
5
4
47.54
47.5
5
47.55
47.54
47.51
47
.
5
4
47.54
4
7
.
5
1
47.51
47.66
47.66
47.66
47.66
47
.
6
6
4
7
.
6
6
47.6
6
47.
6
6
47.
6
6
47.66
4
7
.
6
6
45.20
4
6
.
0
2
4
6
.
2
5
46.22
46.00
4
3
.
1
4
43.37
45.73
45.85
43.72
43.55
44.36
44.53
43.30
43.39
43.90
43.96
46.11
4
4
.
3
9
4
4
.
4
9
4
4
.
7
7
4
4
.
4
6
4
4
.
3
4
4
3
.
4
4
4
3
.
2
2
4
3
.
8
0
4
3
.
7
1
4
3
.
9
2
4
4
.
3
1
4
3
.
8
8
44
.
0
7
43.
7
1
43.
7
2
4
3
.
7
2
4
3
.
7
0
4
3
.
4
9
43.52
43.62
43.61
43.63
43.77
43.58
4
3
.
2
3
43.7
1
43
.
4
5
4
3
.
1
2
4
2
.
8
7
42
.
5
3
42
.
5
7
42.85
42.64
4
3
.
3
8
4
3
.
5
1
43.55 4
3
.
5
9
43.55
4
3
.
3
3
4
3
.
2
2
46.26
46.28
4
7
.
5
2
4
7
.
4
8
45.89
45
.
7
6
45.7
3
45.75
45.68
45.71
45
.
6
8
4
5
.
5
6
45.19
45.23
45.22
44.98
44.60
44.81
42.6
8
4
2
.
7
1
4
2
.
8
4
42.78
42
.
9
2
43.6
6
42
.
9
8
42.39
44.83
44.72
44.93
45.09
45.11
45.65
45.42
45.43
45.59
45
.
6
1
44.60
4
4
.
0
8
43.98
44.64
4
4
.
6
4
4
4
.
0
0
44.50
44.31
44.02
44.0
5
44.67
44.70
45.21
47
.
1
6
47
.
1
6
47.16
47.16
46.13
46.17
47.16
47.51
47.51
47.51
45.94
4
6
.
0
4
46.09
45.66
44.95
4
4
.
9
5
45.69
45.32
45.35
45.25
45.25
45.25
45.25
45.53
4
5
.
2
5
45.25
45.25
45.25
45.25
45.21
4
5
.
2
1
45.
2
5
45.25
45.3
1
45
.
6
3
4
5
.
3
4
4
5
.
6
3
45.7
8
4
5
.
8
2
45.5
0
45.6
3
46.30
45.63
45.6
3
45.59
4
5
.
5
9
45.63
45.63
45.60
4
5
.
5
9
45.6
3
45.63
45.
6
3
45.
6
3
44
.
3
5
44.22
44.24
44.18
44.10
44.57
44.53
44.47
44.46
44
.
5
2
44.52
44.49
44.
4
9
4
4
.
5
2
44.52
44.33
44.43
4
3
.
8
6
43.8
8
44.52
44.52
4
3
.
6
8
4
3
.
6
5
44.52
44.
7
5
4
4
.
7
0
45.25
45.2
5
44.72
44.72
44.72
44
.
7
2
4
4
.
7
2
4
3
.
5
2
43.51
44
.
6
5
4
4
.
6
5
4
4
.
7
2
44.72
43.71
43.1
6
43.07
4
3
.
6
9
43
.
0
2
43.05
44.01
4
3
.
1
9
43.4
9
43.5
3
4
3
.
5
7
4
3
.
9
5
43
.
8
0
44.1
3
43
.
6
3
43.8
0
45.25
45.25
4
4
.
2
3
44.19
4
4
.
3
6
44
.
3
5
4
5
.
0
7
45.12
4
5
.
1
9
45.05
44.69
44.7
4
44.8
5
45.25
45.25
45.25
45.25
45.24
4
5
.
2
5
46.
3
6
46.3
2
45
.
7
6
46.36
46.32
45
.
9
1
4
5
.
8
7
45
.
2
3
46
.
1
4
4
6
.
1
8
45.1
7
46.21
46.24
46.12
45.62
46.13
46.13
45.61
46.04
46.08
4
6
.
3
4
46
.
2
546.2
5
4
6
.
3
6
46.7
2
46
.
8
9
46.8
1
46.89
47.00
4
4
.
5
1
44.
3
144.28
44.4744.27
44.29 44.51
44.65
4
3
.
3
5
4
3
.
3
5
46.31
4
6
.
0
7
46.40
46.52
47.66
4
7
.
6
6
46.55
46.64
44.1
6
44
.
3
4
45.52
45.55 45.32
45.35
47.55
47.5
5
45.83
45
.
8
0
4
7
.
5
5
47
.
5
5
LL 4
6
.
2
6
LL
LL
LL
LL
LL
LL
4
4
.
6
9
44.63
44.58
LL
LL
LL
LL
LL
LL
LL
4
6
.
3
7
LL
LL
LL
LL
LL
LL
LL
LL
4
3
.
3
2
43.43
43.47
4
3
.
5
7
LL
LL 43.30
46.70
LL
44.72
4
4
.
7
2
44
.
0
5
44.13
46
.
5
5
46.47
LL
LL
47.62
47.
6
2
45
.
2
1
45.2
1
LL
4
2
.
7
5
B
O
W
44.7
5
TO
W
45.5
5
47.55
47.55
47.55
47.5
547.5
5
FFE=48.21
BUILDING
9
FFE=48.33
BUILDING
8
44.4
5
42.75
BOW
44.75
TOW
42.7
5
BOW
4
4
.
7
5
T
O
W
42.7
5
BOW
4
4
.
7
5
T
O
W
43.23
41.23
41.23
42.23
0.7%
1.9%
47.38
46.7
7
47.5
6
46.9
5
46.38
47.01
47.01
47.19
46.79
46
.
8
2
47
.
2
6
47.52
47.44
43
.
6
4
43
.
6
4
4
4
.
0
4
44.0
4
4
4
.
0
4
4
4
.
0
4
43
.
9
8
44
.
1
2
42
.
5
9
42.6
2
43.28
43.25
44.60
44.98
45.2
1
44.98
45
.
5
9
45.5
9
44
.
9
8
4
4
.
9
8
4
4
.
5
8
4
4
.
5
8
4
4
.
9
8
4
4
.
9
8
44.98
43.43
43.89
43.9
1
43
.
9
3
4
3
.
8
0
43.94
44
.
6
0
45
.
2
1
4
4
.
2
5
45.7
6
4
5
.
7
9
45.74
45
.
9
0
46.5
8
46
.
7
7
46.62
46.4
3
46.25
46.93
46.57
46.62
46.63 47.24
46.17
4
4
.
6
1
4
4
.
5
0
4
4
.
0
1
4
4
.
0
8
4
7
.
6
6
R
R
R
R
R
R
R R
R
R
R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
46.30
44.76
4
5
.
0
5
4
4
.
7
7
44.77
45.05
4
4
.
7
7
R
R
R
R
R
R
R
R
R
R
R
R
PROPOSED 2'
SIDEWALK CULVERT
PROPOSED
6' CROSSPAN
FOREBAY
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
(1) 6" STEP
0.6%
2.1%
1.9%
0.2%
0.8%
0.8%
2.0%
2.1%
2.0%
2.0%
2.0%
0.6%
2.3%
0.1%
2.
0
%
0.
6
%
0.
6
%
0.
6
%
0.
6
%
2.
9
%
2.
0
%
0.
7
%
0.
8
%
0.
6
%
0.
6
%
0.
9
%
2.0%
2.0%
2.0%
0.
7
%
0.
7
%
0.
7
%
0.
6
%
0.
6
%
2.
0
%
2.
4
%
0.
6
%
0.
0
%
2.
7
%
1.
0
%
0.
6
%
0.
3
%
0.
6
%
0.
6
%
2.
1
%
2.
0
%
2.
0
%
1.
2
%
1.
2
%
1.1%
0.0%
1.9%
2.
0
%
0.
4
%
2.
0
%
0.4%
1.9%
2.0%
0.3%
0.0%
3.0%
2.0%
2.0%
2.0%
2.0%
0.8%
0.
3
%
2.0%
0.
0
%
2.0%
1.
1
%
1.9%
0.5%
0.5%
1.8%
2.
0
%
4
5
.
1
3
46.
5
5
46.5
1
47.55
44.72
4
6
.
8
3
47.51
46.56
47.17
2.
0
%
2.
0
%
46.10
2.
0
%
0.6%
0.6%2.
0
%
1.
6
%
4
4
.
4
1
4
4
.
2
5
4
4
.
7
5
T
O
W
4
2
.
7
5
4
2
.
7
5
45.87
45.96
41.7341.87
FF
E
=
4
7
.
2
4
FFE=43.60
FFE=44.24
FFE=44.41
FFE=43.76FFE=44.57
FFE=43.93
4
3
.
9
1
4
4
.
0
7
4
4
.
0
7
4
4
.
2
4
4
4
.
2
4
43
.
8
1
LL
5.6%
4
3
.
1
6
43.1
2
43
.
4
5
43.52
44
.
1
3
14
.
5
%
LANDSCAPED WALL
22.1%
46.2
1
46.0
9
46.8
4
47.51
46
.
8
4
46.41
4
6
.
5
3
46.62
46.36
46.84
2.
0
%
2.0%
4
7
.
1
7
47.52 47.52
46.8
4
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
6
MATCH LINE - SEE SHEET C 502
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
22
1" = 20'
N/A
C 505
MATCH LINE - SEE SHEET C 508
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
4
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD UD UD
UD
UD
UD
UD
X
X
X
X
X
X
X
FFE=45.19
15
'
U
T
I
L
I
T
Y
EA
S
E
M
E
N
T
DETENTION
POND 1
CO
R
D
O
V
A
R
O
A
D
0.6%
0.
6
%
0.6%
0.
5
%
0.2%
0.6%
0.5%
30' EAE
30' E&BE
26'
FL-FL
30'
FL-FL
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
GARAGE
GA
R
A
G
E
6'
S
I
D
E
W
A
L
K
6'
S
I
D
E
W
A
L
K
6' SIDEWAL
K
RAIN
GARDEN D
RAIN
GARDEN C
BUILDING
2
23.5' E&BE
FFE=44.0
7
FFE=45.38
BUILDING
6
3.
4
%
5.9%
0.
6
%
0.
6
%
0.
5
%
0.
5
%
0.
6
%
0.
7
%
44.72
43.17
43.71
4
4
.
2
7
43.88
43.88
4
4
.
0
4
4
4
.
0
4
42.71
42.14
4
1
.
6
4
42.25
38.96
4
2
.
2
8
4
3
.
7
3
43.83
4
3
.
1
4
43.37
43.30
43.12
4
3
.
1
7
43.35
43.45
43.24
4
3
.
5
2
4
3
.
3
8
43.52
43.40
42.31
42.39
44.02
4
3
.
7
4
4
4
.
3
6
43.97 43.98
43.21
43.2
4
44.28
4
4
.
4
9
44.
4
9
4
4
.
5
2
44.52
4
3
.
6
8
4
3
.
6
5
4
3
.
4
5
43
.
4
9
4
3
.
2
6
43
.
2
7
44.
7
5
4
4
.
7
0
44.52
44.52
44.52
44.52
44.52
44.52
4
4
.
5
2
43.69
44.52
44
.
5
2
43
.
5
7
44.52
44
.
5
2
4
3
.
8
0
43
.
3
5
43.39
4
3
.
4
0
43.55
44.12
43.93
4
3
.
9
5
43.54
43.82
42.85
42.48
42.55
4
2
.
5
8
4
2
.
7
2
43.54
44.3
8
43.80
4
3
.
7
0
44
.
7
2
44.72
44.72
44.72
4
4
.
7
2
44.72
4
4
.
7
2
44.72
4
4
.
6
5
4
4
.
6
5
44
.
6
5
4
4
.
6
5
4
4
.
4
7
44.72
44
.
7
2
44.72
44.72
44.72
4
4
.
7
2
4
3
.
4
1
4
2
.
5
8
42.6
4
4
2
.
4
5
4
2
.
9
9
43.1
2
4
3
.
3
5
43.35
4
3
.
3
5
4
3
.
3
5
42
.
9
5
4
3
.
7
2
4
3
.
6
0
4
3
.
0
8
43
.
0
4
4
3
.
7
2
43.66
43
.
5
9
43
.
6
1
43
.
8
4
43
.
7
3
44.49
44.
4
9
4
4
.
5
2
44.52
42.95
42.92
42
.
6
5
42
.
7
7
41
.
9
5
41.9
4
41.95
4
1
.
9
5
41.96
41
.
0
0
BO
W
44.00
TOW
41
.
5
0
BO
W
43.99
TOW
41
.
5
0
BOW
4
4
.
0
0
TOW
43
.
9
9
BO
W
43.40
TOW
44.
3
2
40
.
5
0
BO
W
43.00
TOW
43.00
TOW
40
.
5
0
BO
W
4
3
.
0
0
T
O
W
43
.
0
0
BO
W
LL
LL
LL
LL
LL
LL
LL
LL
3.
1
%
43.23
41.23
41.23
42.23
42.23
41.23
41.23
43.23
42.23
43
.
1
4
43
.
4
5
4
2
.
9
6
40
.
7
5
39
.
9
0
40.9
3
41.6
4
4
3
.
6
8
43.56
43
.
9
9
44
.
1
3
43.5
6
44
.
2
0
43
.
0
2
42.8
8
43
.
0
4
43
.
8
2
43.9
6
43
.
7
5
4
3
.
8
9
43.80
43.94
R
R
R R
R
R
R
R
R
R
R
R
R
R
0.
5
%
LL
5:1
4:1
6:1
5:1
PROPOSED 2' CONCRETE PAN
PROPOSED POND OUTLET STRUCTURE
PROPOSED
STORM DRAIN
LANDSCAPE
WALL
PROPOSED
LANDSCAPE WALL
CORDOVA ROAD PLAN & PROFILE
SEE SHEET 28-29
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 3
SEE SHEET C 631
2.
0
%
1.
7
%
0.
5
%
1.
9
%
0.
7
%
0.2%0.2%
2.0%
0.0%
1.4%
2.0%
2.
0
%
2.
0
%
0.
7
%
0.
5
%
2.0%
2.0%
2.0%
0.4%
0.3%
0.6%
1.7%
4
3
.
6
6
4
3
.
8
0
42' HALF ROW
52' FL-FL
HALF ROW VARIES
FF
E
=
4
3
.
7
1
FF
E
=
4
3
.
8
8
43.
5
4
43.
3
8
FFE=43.43
FFE=43.60
FFE=44.24
4
3
.
9
1
4
3
.
7
4
4
3
.
9
1
4
4
.
0
7
14
.
5
%
15
.
3
%
POND DEPTH GAGE
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 503
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
23
1" = 20'
N/A
C 506
MATCH LINE - SEE SHEET C 509
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
5
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
U
D
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD UD UD UD
NO
R
T
H
LE
M
A
Y
AV
E
N
U
E
FFE=47.58
EXISTING 5' WALK
DUFF DRIVE
9' UTILITY EASEMENT
1
7
.
5
%
0.4%
0.
6
%
0.5%
2.
0
%
0.5%
0.
6
%
0.
6
%
26' EAE
24' EAE
30' E&BE
35' E&BE
FITNESS CENTER
CA
R
R
I
A
G
E
H
O
U
S
E
2
CA
R
R
I
A
G
E
H
O
U
S
E
3
6' SIDEWALK
BUILDING
7
CARRIAGE HOUSE 1
FF
E
=
4
8
.
5
1
FFE=47.95
0.6%
48.39
47.02
47.4
1
47.15
46.66
4
7
.
2
2
46.46
4
6
.
0
0
47.25
47.40
47
.
8
5
47.10
46.98
4
6
.
0
6
46.53
46.52
47.96
41.2
1
41.8
8
4
6
.
8
1
46.7
9
48.65
4
7
.
1
5
47.15
4
8
.
7
2
48.65
48.
3
2
47.23
47.3746.94
47.15
46.90
46.90
48.32
48.04
47.96
47.05
45.62
46.02
45.80
46.05
46.38
4
6
.
6
3
46.78
48.0
5
47.95
47.8
7
47
.
6
1
4
7
.
9
5
47.95
47.95
47.95
47.
9
5
47.
6
2
47.95
47.
9
5
47.95
4
7
.
8
5
48.04
47.94
47.
9
6
47.
9
4
47.77
47.45
47.29
4
7
.
3
4
47.54
47.82
47.8
2
46
.
9
7
4
6
.
8
5
47.04
47.10
46
.
5
2
46
.
4
9
4
6
.
2
0
46.34
47.71
46.3
1
46.1
6
46
.
5
9
45
.
7
5
45.9
3
45.77
45.98
45.32
45.56
46.5
3
46
.
4
5
46.3
0
46.30
4
8
.
4
3
48.43
48.51
48.5148.32
4
8
.
1
1
48.01
48.40
48.51
47.84
47.84
47
.
4
0
46.8
4
47
.
5
1
4
7
.
4
1
47
.
4
1
46.
8
4
46.92
46.92
46.9
2
46.92
4
6
.
4
3
4
6
.
9
2
46.9
2
46.92
46.92
46.92
46.92
46
.
9
2
4
6
.
9
2
46.9
2
46.92
46
.
9
2
4
7
.
3
8
4
7
.
1
0
46.96
47.0
0
47.1
4
47
.
4
1
4
7
.
2
0
47.22
47.22
4
7
.
2
2
4
7
.
2
2
47.14
47.45
4
7
.
3
2
47
.
4
0
47.44
47.00
47.29
47.
2
8
47.
4
7
47.
4
5
46.6
4
46
.
5
9
47.79
47.64
47.11 47.0
6
48.57
48.6
6
48
.
6
3
48.
6
0
48.
7
6
4
8
.
4
1
48.3
1
48.
8
9
48.78
45.8
3
48.05
47.37
47.47
45.17
47.48 47.
5
8
4
7
.
9
7
47.84
47.61
47.61
47.
9
5
47
.
7
0
LL
LL
LL
LL
LL
LL
LLLL
LL
46.92
46.92
46.92 46.92LLLL
46.80 46.8046.7
7
LLLL
LL
4
7
.
4
9
47.43
1.
8
%
2.0%
2.0%
0.5%
0.0%
48.5
1
4
7
.
5
2
47.25
47
.
5
2
47
.
5
2
47.52
47.18
47.1847.
4
6
47.84
47.17
47.1
4
47.26
47.20
45.73
47.2
1
47.4
2
47.32
47.62
48.23
45
.
9
1
46
.
3
0
46
.
3
2
46.3
6 46.0
5
46.19
46
.
1
4
R
R R R
R
R
R
R
4:1
4:1
PROPOSED STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2' SIDEWALK
CHASE (TYP.)
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
STORM DRAIN 5
SEE SHEET C 633
2.0%
2.0%
2.0%
1.8%
0.3%
11.8%
1.9%
1.6%
0.2%0.1%
0.3%0.5%
0.1%0.4%
2.0%
0.0%
0.2%
2.0%
2.0%
1.9%1.
6
%
2.
0
%
2.
0
%
0.
7
%
2.
0
%
2.
0
%
0.
1
%
2.
0
%
3.
7
%
1.
1
%
0.
5
%
4
6
.
0
3
4
6
.
2
5
46.0
3
46.0
3
45.9
5
46.4
4
4
5
.
9
1
47.5
2
47
.
5
2
FF
E
=
4
8
.
6
5
FF
E
=
4
8
.
0
5
47
.
7
1
2
.
6
%
46.3
9
46
.
9
3
48.2
8
48.36
46.40
46.61
4
6
.
7
8
47.62
47.95
48.05
4
8
.
6
5
48.32
2.9%
48.
1
8
48.61
46.92
47.95
47.63
47.05
47.71
4
8
.
3
7
48.47
48.05
48.05
48.05 47.54
48.6548.65
48.37
4
6
.
2
5
47
.
8
3
FFE=48.51
48.3
4
47.84
47.34
47.84
48.51
2.0%
2.0%
2.
0
%
2.0%
47.5247.52
46.9
8
47.34
47.25
4
6
.
8
4
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
8
MATCH LINE - SEE SHEET C 504
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
24
1" = 20'
N/A
C 507
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD
UD
UDUD
UD
UD
FFE=45.91
FFE=46.93
DUFF DRIVE
9' UTILITY
EASEMENT
DUFF DRIVE
9' UTILITY
EASEMENT
2.1%0.5%
0.
6
%
0.
5
%
0.
6
%
0.8%
3.
3
%
3.
0
%
0.6%0.6%
0.0%
0.
3
%
0.6%
2.7%
0.6%
2.9%
CLUBHOUSE
FFE=47.51
26' EAE
26' EAE
26' EAE
26' EAE
30' E&BE
30' E&BE
30' E&BE
26'
FL-FL
24'
FL-FL
26'
FL-FL
26'
FL-FL
GARAGE
10
'
S
I
D
E
W
A
L
K
10
'
S
I
D
E
W
A
L
K
6' SIDEWALK
6' SIDEWALK
6'
S
I
D
E
W
A
L
K
RAIN
GARDEN A
BUILDING
5
BUILDING
4
26'
FL-FL
26' EAE
LEASING
0.0%
4.1%
0.5%
2.7%0.1%
0.3%
1.1%
0.6%
0.
6
%
0.
6
%
45.25
45.25
46.26
45.62
35.71
4
6
.
2
2
46.4
5
47.5
1
4
6
.
9
2
45.51
45.43
4
5
.
1
1
44.75
44.60
46.09
46.23
45.86
45.63
45.61
45
.
6
1
45.50
4
4
.
6
7
4
4
.
3
5
4
2
.
5
4
43.48
43.37
42
.
8
8
4
2
.
6
6
4
3
.
4
5
43
.
4
2
43.07
46.06
45.25
46.30
46.7
9
4
6
.
7
9
46
.
9
2
46
.
9
2
45.94
46.15
45.90 45.01
4
5
.
3
2
45.56
45.85
45.66
44.81
45.00
4
3
.
8
8
45.75
46
.
5
3
46
.
4
5
4
6
.
5
3
4
6
.
4
5
4
5
.
7
4
4
5
.
7
6
4
5
.
7
4
45.9
3
46.0
2
46
.
5
3
45.87
45.22
4
5
.
1
1
4
5
.
0
4
4
4
.
9
0
44
.
6
6
45
.
0
5
45
.
1
9
45.35
45.2845
.
3
2
44.96
44.78
4
4
.
2
4
44.57
44.36
44.25
4
4
.
2
4
4
4
.
1
0
44.23
43.95
43.87
44.16
4
3
.
7
1
4
3
.
7
7
4
4
.
1
8
44.19
44.30
4
3
.
5
6
4
3
.
4
9
4
3
.
4
0
4
3
.
2
4
42.6
8
4
2
.
7
1
4
2
.
8
4
42.78
42.9
2
43.6
6
42
.
9
8
42.39
43.33
45.04
44.97
44
.
7
4
44
.
8
4
45
.
2
9
45
.
2
6
4
5
.
2
1
46.02
45.91
45.88
45.86
46.18
45.53
45
.
3
0
45.31
47.4
0
47
.
5
1
4
7
.
4
0
4
7
.
5
1
4
7
.
5
1
47.29
4
7
.
2
9
46.84
4
7
.
5
1
47.5
1
46.
8
4
4
7
.
4
2
47.51
4
7
.
5
1
4
6
.
0
3
45.25
4
5
.
9
4
45.97
46.09
45.25
45.25
4
5
.
2
5
4
5
.
2
5
45.21
4
5
.
2
1
45.
2
5
45.25
43.0
2
4
3
.
0
5
44.01
43.19
43
.
4
9
43.5
3
43.57 4
3
.
9
5
43
.
8
0
44
.
1
3
43
.
6
3
43
.
8
0
4
4
.
1
9
44.30
43.47
43.65
44.63
44.52
44.63
4
4
.
5
2
45.25
4
5
.
2
5
45.25
45.25
45.25
4
5
.
2
5
45.12
45.21
44.40
44.29
44.93
44.90
45.63
45.56
4
5
.
4
7
45.42
45.46
45.53
45.91
46.9
2
46
.
9
2
46
.
9
2
46
.
9
2
46.92
4
6
.
6
4
46.6
6
46.55
46.
5
8
46.26
46
.
2
6
46.26
46
.
2
6
46.22
46
.
2
2
4
5
.
2
6
44.89
46
.
2
6
4
6
.
2
6
4
6
.
2
6
46.26
46.2
6
4
6
.
2
6
46.2
6
4
6
.
2
6
46.2
2
46.26
46
.
2
6
4
6
.
2
6
46.26
4
6
.
2
6
46.26
45.82
45.81
45.72
45.69
45.80
45.74
4
5
.
7
7
45.8
0
45.53
45
.
5
5
45.40
45
.
4
3
4
5
.
2
2
45.2
5
4
5
.
1
1
45.1
4
44.89
44
.
9
2
44.73
44.7
7
4
4
.
7
6
44.6
7
46.2
6
46.26
4
6
.
2
6
46.26
4
5
.
8
7
4
6
.
2
6
4
6
.
2
2
46.2
2
46.26
4
6
.
2
6
4
6
.
2
9
46.40
4
6
.
2
0
4
6
.
2
8
46.47
46.40
4
6
.
3
9
4
6
.
2
5
46.3
7
46
.
4
5
46.26
46
.
8
8
43.57
45.8
0
45.6
9
FFE=47.51
45
.
3
0
LL LL
LL
LL
LL
LL
LL
LL
46.92 46.92LL
46.80 46.80
LL LL LL
45
.
0
3
44.7
1
LLLLLL
LL LL
47
.
4
0
46.88
46.70
44.5
0
43.5
0
43
.
5
0
43
.
5
0
43.5
0
44.5
0
44.5
0
44
.
5
0
44.5
0
46.2
6
4
6
.
2
6
47.44
47
.
5
2
47
.
5
2
47.5
2
4
6
.
7
9
4
6
.
7
9
4
6
.
7
9
46
.
3
9
4
5
.
0
9
4
5
.
6
7
45.61 45.61 45.55
46.16
45.61
4
5
.
5
1
4
6
.
1
1
45.61 45.48
45
.
6
2
43.97
44.53
44.59
44.60
4
5
.
1
4
46
.
5
8
46.7
7
46.62
46.93
46.87
47.02
4
6
.
8
9
4
6
.
8
0
4
6
.
9
5
4
6
.
8
6
4
6
.
3
4
47.41
44.6045.21
R
R
R R
R
R
R R R R R R
R
R
R
R
RR R
R
R
R
R
R
R
R
R
R
R
FF
E
=
4
4
.
6
3
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
FOREBAY
PROPOSED 2' SIDEWALK
CHASE (TYP.)
PROPOSED 2' SIDEWALK
CHASE (TYP.)
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 5
SEE SHEET C 633
0.5%0.6%
2.0%
1.2%
2.4%
2.0%
1.1%
2.3%
2.0%
2.0%
0.3%
0.6%
1.7%
2.0%
0.8%
0.3%
0.4%
2.
0
%
0.
4
%
0.
6
%
0.
7
%
2.
0
%
2.
0
%
0.
4
%
1.
2
%
0.
5
%
2.
0
%
1.
9
%
1.
0
%
2.
0
%
2.
0
%
2.
7
%
2.
6
%
2.
0
%
1.
6
%
0.4%
1.8%
0.5%0.4%
3.
0
%
0.
0
%
2.0%
0.
3
%
2.0%
2.
0
%
4
5
.
2
4
4
5
.
1
3
4
4
.
9
7
4
4
.
5
0
46.0
3
44.83
45.09
47.5
2
47
.
5
2
4
7
.
5
1
45
.
6
5
46.03
43.57
43.74
43.74
43.91
43.91
44.07
44.07
44.24
FF
E
=
4
4
.
6
3
FF
E
=
4
4
.
4
7
FF
E
=
4
4
.
4
7
FF
E
=
4
4
.
3
0
FF
E
=
4
4
.
3
0
FF
E
=
4
4
.
1
3
FF
E
=
4
4
.
1
3
44.30
44.13
44.13
43.97
43.97
43.80
4
3
.
1
6
43
.
1
2
43
.
4
5
43.52
44
.
1
3
44.30
44.13
44.13
43.97
43.97
43.80
25.0%25.0%
21
.
0
%
20
.
8
%
46
.
8
4
46.84
4
7
.
4
0
4
7
.
4
0
4.3%
46.62
46.84
LL
2.0%
2.0%
2.
0
%
2.0%
2.0%
2.0%
47.5247.52
47.154
7
.
2
2
2.
0
%
2.
0
%
46.80
46.7
9
4
7
.
5
1
4
6
.
8
4
46.84
46.84
4
6
.
8
4
4
6
.
8
4
4
6
.
8
4
4
6
.
8
4
46
.
8
4
46.8
4
46.84
47.40
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
9
MATCH LINE - SEE SHEET C 505
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
25
1" = 20'
N/A
C 508
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
7
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
U
D
U
D
UD
UD
UD
ST
ST
S
T
S
T
ST ST
ST ST
ST ST
/ / / / / / / // / / / / / / /
9' UTILITY
EASEMENT
DETENTION
POND 2
CO
R
D
O
V
A
R
O
A
D
9' UTILITY
EASEMENT
0.5%
0.
5
%
0.6%
0.5%
2.9%
30' EAE
42' HALF ROW
52' FL-FL
RAIN
GARDEN C
26'
FL-FL
26' EAE
GA
R
A
G
E
DUFF DRIVE
5.9%
0.
6
%
0.
6
%
44.67
44.35
41.64
4
2
.
1
1
42.69
42.25
3
8
.
8
7
4
2
.
2
8
3
4
.
9
6
34.97
3
5
.
7
9
40.0
3
44.24
44.57
42.31
42.39
43.33
4
3
.
5
7
43.9
1
44.57
43.47
43.64
43.39
42.
9
8
42.86
42.93
4
3
.
6
9
4
3
.
7
3
43.4
7
43
.
5
9
43.1
4
43.1
2
42.76
42.68
4
2
.
7
2
4
2
.
6
7
42.78
42.7
8
4
2
.
4
6
4
2
.
3
9
40.9
8
39
.
9
0
40
.
7
5
41.5
0
41
.
5
0
41
.
5
0
41.5
0
4
0
.
9
0
FF
E
=
4
4
.
5
7
4:1
6:1
7:
1
6:
1
4:
1
4:1
EXISTING
STORM DRAIN
PROPOSED POND OUTLET STRUCTURE
EXISTING
STORM DRAIN
PROPOSED
STORM DRAIN
CORDOVA ROAD PLAN & PROFILE
SEE SHEETS C 510-C 511
PROPOSED STORM DRAIN
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
PROPOSED 2'
CONCRETE PAN
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
HALF ROW VARIES
FF
E
=
4
4
.
4
1
FF
E
=
4
4
.
2
4
FF
E
=
4
4
.
0
7
FF
E
=
4
3
.
9
1
43.57
43.74
43.74
43.91
43.91
44.07
44.07
44.24
POND DEPTH GAGE
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
MATCH LINE - SEE SHEET C 506
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
GR
A
D
I
N
G
P
L
A
N
26
1" = 20'
N/A
C 509
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
5
0
8
C 501
C 502
C 503
C 504
C 505
C 506
C 507
C 508
C 509
UD
UD
UD
UD UD UD UD UD UD
26' EAE
26' EAE
35' E&BE
GARAGE
6' SIDEWALK
26' PAE
EASEMENT
EXCLUSION
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 8
SEE SHEET C 634
STORMTECH CHAMBERS
SEE SHEETS C 634 & C 807
37.8
3
SG
3
7
.
7
3
SG
37.49
SG
37.3
8
SG
4
2
.
6
6
F
G
42.85
FG
4
3
.
3
3
FG
43.
8
2
FG
42.17
FG
4
3
.
1
8
F
G
4
2
.
5
8
FG
4
3
.
3
4
FG
4
3
.
0
6
F
G
37.80
SG
0.5%
0.5%
0.
5
%
0.
5
%
0.
5
%
0.5%
0.5%
INLET 8-4
INV. OUT=4939.05 (E)
FG=4942.76
36.18 LF 18" HDPE @ 0.50%
53.59 LF 18" HDPE @ 0.30%
CHAMBER WEIR MH 8-2
INV. IN=4938.87 (NW)
INV. IN=4938.87 (NE)
INV. OUT=4938.87 (S)
FG=4943.10
4.75 LF 18" HDPE @ 0.00%
CHAMBER MANIFOLD 8-3
INV. IN=4938.87 (W)
INV. IN=4938.87 (NE)
INV. OUT=4938.87 (SE)
FG=4942.78
TEE 8-2.2
INV. IN=4938.87 (NW)
INV. IN=4938.87 (NE)
INV. OUT=4938.87 (SE)
FG=???
END CHAMBER 8-3
INV. OUT=4939.17 (SW)
FG=???
END CHAMBER 8-2.2
INV. OUT=4939.17 (SW)
FG=???
END CHAMBER 8-2
INV. OUT=4939.17 (SW)
FG=???
STORM DRAIN 8
SEE SHEET C 634
BEGIN CHAMBER 8-3
INV. IN=4938.89 (NE)
INV. OUT=4938.89 (SW)
FG=???
BEGIN CHAMBER 8-2.2
INV. IN=4938.89 (NE)
INV. OUT=4938.89 (SW)
FG=???
BEGIN CHAMBER 8-2
INV. IN=4938.89 (NE)
INV. OUT=4938.89 (SW)
FG=4943.33
4.58 LF 18" HDPE @ 0.50%
4.54 LF 18" HDPE @ 0.50%
4.61 LF 18" HDPE @ 0.50%
END CHAMBER 8-2.1
INV. IN=4938.89 (SW)
FG=???
TEE 8-2.1
INV. IN=4938.87 (NW)
INV. OUT=4938.89 (NE)
INV. OUT=4938.87 (SE)
FG=???
4.52 LF 18" HDPE @ 0.50%
BEGIN CHAMBER 8-2.1
INV. IN=4938.87 (SW)
INV. OUT=4939.17 (NE)
FG=???
0.5%
0.5%
0.
5
%
0.
5
%
0.5%
0.5%
0.
5
%
4.75 LF 18" HDPE @ 0.00%
4.75 LF 18" HDPE @ 0.00%
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR
FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS
ARE FINISHED GRADE ELEVATIONS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE
PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS
EASEMENT" IN THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG
N LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED
EQUIPMENT THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL
BE PROMPTLY REPLACED AND/OR REPAIRED AT NO COST TO THE CITY.
IRRIGATION PLANS FOR THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED
AND/OR REPAIRED AT NO COST TO THE CITY.
10.LEVEL LANDINGS [LL] TO BE 5'x5' W/ 2% MAX SLOPE AND CROSS-SLOPE
11.ALL FOREBAYS MUST TO BE PLACED ON NATIVE OR COMPACTED SOILS
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
RROOF DRAIN DOWN SPOUTS
PROPOSED GRADE BREAK
LEGEND
NOTES
LEVEL LANDING LL
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SU
B
G
R
A
D
E
P
L
A
N
27
1" = 10'
N/A
C 510
NOTE: SEE SHEET C 807 FOR MORE STORMTECH CHAMBER DETAILS.
St
o
r
m
T
e
c
h
88
8
-
8
9
2
-
2
6
9
4
|
WW
W
.
S
T
O
R
M
T
E
C
H
.
C
O
M
®
Ch
a
m
b
e
r
S
y
s
t
e
m
INSPECTION & MAINTENANCE
STEP 1)INSPECT ISOLATOR ROW PLUS FOR SEDIMENT
A.INSPECTION PORTS (IF PRESENT)
A.1.REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN
A.2.REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED
A.3.USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG
A.4.LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL)
A.5.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
B.ALL ISOLATOR PLUS ROWS
B.1.REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS
B.2.USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE
i)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY
ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE
B.3.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
STEP 2)CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS
A.A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED
B.APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN
C.VACUUM STRUCTURE SUMP AS REQUIRED
STEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS.
STEP 4)INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.
NOTES
1.INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS
OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.
2.CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.
SC-740 ISOLATOR ROW PLUS DETAIL
NTS
SC-740 END CAP
OPTIONAL INSPECTION PORT
SC-740 CHAMBER
STORMTECH HIGHLY RECOMMENDS
FLEXSTORM INSERTS IN ANY UPSTREAM
STRUCTURES WITH OPEN GRATES
ONE LAYER OF ADSPLUS125 WOVEN GEOTEXTILE BETWEEN
FOUNDATION STONE AND CHAMBERS
5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS
ELEVATED BYPASS MANIFOLD
24" (600 mm) HDPE ACCESS PIPE REQUIRED
USE EZ END CAP PART #: SC740ECEZ
INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE
PART#: SC74024RAMP
NYLOPLAST
SUMP DEPTH TBD BY
SITE DESIGN ENGINEER
(24" [600 mm] MIN RECOMMENDED)
SC-740 6" (150 mm) INSPECTION PORT DETAIL
NTS
18" (450 mm) MIN WIDTH
CONCRETE SLAB
8" (200 mm) MIN THICKNESS
* THE PART# 2712AG6IPKIT CAN BE
USED TO ORDER ALL NECESSARY
COMPONENTS FOR A SOLID LID
INSPECTION PORT INSTALLATION
6" (150 mm) INSERTA TEE
PART# 6P26FBSTIP*
INSERTA TEE TO BE CENTERED ON
CORRUGATION CREST
PAVEMENT
CONCRETE COLLAR
CONCRETE COLLAR NOT REQUIRED
FOR UNPAVED APPLICATIONS
12" (300 mm) NYLOPLAST UNIVERSAL INLINE
DRAIN BODY W/SOLID HINGED COVER
PART# 2712AGSB*
SOLID COVER: 1299CGC*
6" (150 mm) SDR35 PIPE
SC-740 CHAMBER
46
4
0
T
R
U
E
M
A
N
B
L
V
D
HI
L
L
I
A
R
D
,
O
H
4
3
0
2
6
1-
8
0
0
-
7
3
3
-
7
4
7
3
DA
T
E
:
DR
A
W
N
:
A
D
PR
O
J
E
C
T
#
:
CH
E
C
K
E
D
:
N
/
A
TH
I
S
D
R
A
W
I
N
G
H
A
S
B
E
E
N
P
R
E
P
A
R
E
D
B
A
S
E
D
O
N
I
N
F
O
R
M
A
T
I
O
N
P
R
O
V
I
D
E
D
T
O
A
D
S
U
N
D
E
R
T
H
E
D
I
R
E
C
T
I
O
N
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
O
R
O
T
H
E
R
P
R
O
J
E
C
T
R
E
P
R
E
S
E
N
T
A
T
I
V
E
.
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
S
H
A
L
L
R
E
V
I
E
W
T
H
I
S
D
R
A
W
I
N
G
P
R
I
O
R
T
O
C
O
N
S
T
R
U
C
T
I
O
N
.
I
T
I
S
T
H
E
U
L
T
I
M
A
T
E
RE
S
P
O
N
S
I
B
I
L
I
T
Y
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
T
O
E
N
S
U
R
E
T
H
A
T
T
H
E
P
R
O
D
U
C
T
(
S
)
D
E
P
I
C
T
E
D
A
N
D
A
L
L
A
S
S
O
C
I
A
T
E
D
D
E
T
A
I
L
S
M
E
E
T
A
L
L
A
P
P
L
I
C
A
B
L
E
L
A
W
S
,
R
E
G
U
L
A
T
I
O
N
S
,
A
N
D
P
R
O
J
E
C
T
R
E
Q
U
I
R
E
M
E
N
T
S
.
DA
T
E
DR
W
CH
K
DE
S
C
R
I
P
T
I
O
N
LA
N
D
I
N
G
A
T
L
E
M
A
Y
FO
R
T
C
O
L
L
I
N
S
,
C
O
,
U
S
A
SHEET
OF4 6
St
o
r
m
T
e
c
h
88
8
-
8
9
2
-
2
6
9
4
|
WW
W
.
S
T
O
R
M
T
E
C
H
.
C
O
M
®
Ch
a
m
b
e
r
S
y
s
t
e
m
ACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS
PLEASE NOTE:
1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE".
2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR
COMPACTION REQUIREMENTS.
4.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
NOTES:
1.CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
2.SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
3.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH
CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
4.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
5.REQUIREMENTS FOR HANDLING AND INSTALLATION:
·TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.
·TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 2”.
·TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE GREATER THAN OR EQUAL TO 550 LBS/FT/%. THE ASC IS DEFINED IN SECTION 6.2.8
OF ASTM F2418. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR
YELLOW COLORS.
MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL
CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C'
LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED
GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D'
LAYER.
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE
EMBEDMENT STONE ('B' LAYER) TO 18" (450 mm) ABOVE THE TOP OF THE
CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C'
LAYER.
GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR
PROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS
LAYER.
AASHTO M145¹
A-1, A-2-4, A-3
OR
AASHTO M43¹
3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10
BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER
THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN
6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR
WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR
PROCESSED AGGREGATE MATERIALS. ROLLER GROSS
VEHICLE WEIGHT NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC
FORCE NOT TO EXCEED 20,000 lbs (89 kN).
B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE
FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE.CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED.
A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO
THE FOOT (BOTTOM) OF THE CHAMBER.CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3
18"
(450 mm) MIN*
8'
(2.4 m)
MAX
6" (150 mm) MIN
D
C
B
A
12" (300 mm) MIN 12" (300 mm) TYP51" (1295 mm)6"
(150 mm) MIN
30"
(760 mm)
DEPTH OF STONE TO BE DETERMINED
BY SITE DESIGN ENGINEER 6" (150 mm) MIN
*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED
INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,
INCREASE COVER TO 24" (600 mm).
PAVEMENT LAYER (DESIGNED
BY SITE DESIGN ENGINEER)
SC-740
END CAP
EXCAVATION WALL (CAN
BE SLOPED OR VERTICAL)
PERIMETER STONE
(SEE NOTE 4)
SUBGRADE SOILS
(SEE NOTE 3)
46
4
0
T
R
U
E
M
A
N
B
L
V
D
HI
L
L
I
A
R
D
,
O
H
4
3
0
2
6
1-
8
0
0
-
7
3
3
-
7
4
7
3
DA
T
E
:
DR
A
W
N
:
A
D
PR
O
J
E
C
T
#
:
CH
E
C
K
E
D
:
N
/
A
TH
I
S
D
R
A
W
I
N
G
H
A
S
B
E
E
N
P
R
E
P
A
R
E
D
B
A
S
E
D
O
N
I
N
F
O
R
M
A
T
I
O
N
P
R
O
V
I
D
E
D
T
O
A
D
S
U
N
D
E
R
T
H
E
D
I
R
E
C
T
I
O
N
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
O
R
O
T
H
E
R
P
R
O
J
E
C
T
R
E
P
R
E
S
E
N
T
A
T
I
V
E
.
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
S
H
A
L
L
R
E
V
I
E
W
T
H
I
S
D
R
A
W
I
N
G
P
R
I
O
R
T
O
C
O
N
S
T
R
U
C
T
I
O
N
.
I
T
I
S
T
H
E
U
L
T
I
M
A
T
E
RE
S
P
O
N
S
I
B
I
L
I
T
Y
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
T
O
E
N
S
U
R
E
T
H
A
T
T
H
E
P
R
O
D
U
C
T
(
S
)
D
E
P
I
C
T
E
D
A
N
D
A
L
L
A
S
S
O
C
I
A
T
E
D
D
E
T
A
I
L
S
M
E
E
T
A
L
L
A
P
P
L
I
C
A
B
L
E
L
A
W
S
,
R
E
G
U
L
A
T
I
O
N
S
,
A
N
D
P
R
O
J
E
C
T
R
E
Q
U
I
R
E
M
E
N
T
S
.
DA
T
E
DR
W
CH
K
DE
S
C
R
I
P
T
I
O
N
LA
N
D
I
N
G
A
T
L
E
M
A
Y
FO
R
T
C
O
L
L
I
N
S
,
C
O
,
U
S
A
SHEET
OF3 6
St
o
r
m
T
e
c
h
88
8
-
8
9
2
-
2
6
9
4
|
WW
W
.
S
T
O
R
M
T
E
C
H
.
C
O
M
®
Ch
a
m
b
e
r
S
y
s
t
e
m
UNDERDRAIN DETAIL
NTS
A
A
B B
SECTION A-A
SECTION B-B
DUAL WALL
PERFORATED
HDPE
UNDERDRAIN
ADS GEOSYNTHETICS 601T
NON-WOVEN GEOTEXTILE
STORMTECH END CAP
ADS GEOSYNTHETICS 601T
NON-WOVEN GEOTEXTILE
STORMTECH
CHAMBER
OUTLET MANIFOLD
STORMTECH END CAP
STORMTECH
CHAMBERS
NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER
4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS
6" (150 mm) TYP FOR SC-740, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS
FOUNDATION STONE
BENEATH CHAMBERS
FOUNDATION STONE
BENEATH CHAMBERS
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH)51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm)
CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³)
MINIMUM INSTALLED STORAGE*74.9 CUBIC FEET (2.12 m³)
WEIGHT 75.0 lbs.(33.6 kg)
*ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS
SC-740 TECHNICAL SPECIFICATION
NTS
BUILD ROW IN THIS DIRECTION
OVERLAP NEXT CHAMBER HERE
(OVER SMALL CORRUGATION)
START END
90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH
A A
C
B
51.0"
(1295 mm)
30.0"
(762 mm)
45.9" (1166 mm)12.2"
(310 mm)
29.3"
(744 mm)
PART #STUB A B C
SC740EPE06T / SC740EPE06TPC 6" (150 mm)10.9" (277 mm)18.5" (470 mm)---
SC740EPE06B / SC740EPE06BPC ---0.5" (13 mm)
SC740EPE08T /SC740EPE08TPC 8" (200 mm)12.2" (310 mm)16.5" (419 mm)---
SC740EPE08B / SC740EPE08BPC ---0.6" (15 mm)
SC740EPE10T / SC740EPE10TPC 10" (250 mm)13.4" (340 mm)14.5" (368 mm)---
SC740EPE10B / SC740EPE10BPC ---0.7" (18 mm)
SC740EPE12T / SC740EPE12TPC 12" (300 mm)14.7" (373 mm)
12.5" (318 mm)---
SC740EPE12B / SC740EPE12BPC ---1.2" (30 mm)
SC740EPE15T / SC740EPE15TPC 15" (375 mm)18.4" (467 mm)9.0" (229 mm)---
SC740EPE15B / SC740EPE15BPC ---1.3" (33 mm)
SC740EPE18T / SC740EPE18TPC 18" (450 mm)19.7" (500 mm)5.0" (127 mm)---
SC740EPE18B / SC740EPE18BPC ---1.6" (41 mm)
SC740ECEZ*24" (600 mm)18.5" (470 mm)---0.1" (3 mm)
ALL STUBS, EXCEPT FOR THE SC740ECEZ ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE
STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT
1-888-892-2694.
* FOR THE SC740ECEZ THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm).
BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.
NOTE: ALL DIMENSIONS ARE NOMINAL
PRE-FAB STUB AT BOTTOM OF END CAP WITH FLAMP END WITH "BR"
PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"
PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"
PRE-CORED END CAPS END WITH "PC"
46
4
0
T
R
U
E
M
A
N
B
L
V
D
HI
L
L
I
A
R
D
,
O
H
4
3
0
2
6
1-
8
0
0
-
7
3
3
-
7
4
7
3
DA
T
E
:
DR
A
W
N
:
A
D
PR
O
J
E
C
T
#
:
CH
E
C
K
E
D
:
N
/
A
TH
I
S
D
R
A
W
I
N
G
H
A
S
B
E
E
N
P
R
E
P
A
R
E
D
B
A
S
E
D
O
N
I
N
F
O
R
M
A
T
I
O
N
P
R
O
V
I
D
E
D
T
O
A
D
S
U
N
D
E
R
T
H
E
D
I
R
E
C
T
I
O
N
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
O
R
O
T
H
E
R
P
R
O
J
E
C
T
R
E
P
R
E
S
E
N
T
A
T
I
V
E
.
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
S
H
A
L
L
R
E
V
I
E
W
T
H
I
S
D
R
A
W
I
N
G
P
R
I
O
R
T
O
C
O
N
S
T
R
U
C
T
I
O
N
.
I
T
I
S
T
H
E
U
L
T
I
M
A
T
E
RE
S
P
O
N
S
I
B
I
L
I
T
Y
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
T
O
E
N
S
U
R
E
T
H
A
T
T
H
E
P
R
O
D
U
C
T
(
S
)
D
E
P
I
C
T
E
D
A
N
D
A
L
L
A
S
S
O
C
I
A
T
E
D
D
E
T
A
I
L
S
M
E
E
T
A
L
L
A
P
P
L
I
C
A
B
L
E
L
A
W
S
,
R
E
G
U
L
A
T
I
O
N
S
,
A
N
D
P
R
O
J
E
C
T
R
E
Q
U
I
R
E
M
E
N
T
S
.
DA
T
E
DR
W
CH
K
DE
S
C
R
I
P
T
I
O
N
LA
N
D
I
N
G
A
T
L
E
M
A
Y
FO
R
T
C
O
L
L
I
N
S
,
C
O
,
U
S
A
SHEET
OF5 6
STORMTECH CHAMBER DETAILS
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
PROPOSED
GRADE
EXISTING
GROUND
EXISTING
GROUND
PROPOSED
GRADE
END CONSTRUCTION
150.0' VC
HP ELEV = 4943.22
HP STA = 18+81.52
PVI STA = 18+81.52
PVI ELEV = 4943.43
BVCS: 18+06.52
BVCE: 4943.01
EVCS: 19+56.52
EVCE: 4943.01
A.D. = 1.10
K = 136.36
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
FG
=
4
9
4
3
.
6
2
FG
=
4
9
4
3
.
7
8
FG
=
4
9
4
3
.
7
5
FG
=
4
9
4
3
.
5
5
FG
=
4
9
4
3
.
2
7
FG
=
4
9
4
3
.
0
0
FG
=
4
9
4
2
.
8
1
FG
=
4
9
4
2
.
8
1
FG
=
4
9
4
3
.
0
0
FG
=
4
9
4
3
.
1
8
FG
=
4
9
4
3
.
1
5
FG
=
4
9
4
2
.
9
2
FG
=
4
9
4
2
.
5
8
FG
=
4
9
4
2
.
4
2
FG
=
4
9
4
2
.
4
7
FG
=
4
9
4
2
.
7
0
FG
=
4
9
4
2
.
9
8
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
FG
=
4
9
4
2
.
5
1
FG
=
4
9
4
2
.
9
1
FG
=
4
9
4
3
.
0
2
FG
=
4
9
4
2
.
8
5
FG
=
4
9
4
2
.
5
8
FG
=
4
9
4
2
.
3
0
FG
=
4
9
4
2
.
0
5
FG
=
4
9
4
2
.
0
6
FG
=
4
9
4
2
.
3
2
FG
=
4
9
4
2
.
4
9
FG
=
4
9
4
2
.
4
5
FG
=
4
9
4
2
.
2
0
FG
=
4
9
4
1
.
8
7
FG
=
4
9
4
1
.
6
2
FG
=
4
9
4
1
.
7
7
FG
=
4
9
4
2
.
0
3
FG
=
4
9
4
2
.
3
1
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
0.55%-0.55%
0.55%
-0.70%0.55%
PVI STA = 9+84.17
PVI ELEV = 4943.53 PVI STA = 18+06.52
PVI ELEV = 4943.01
BV
C
S
:
9
+
9
3
.
5
0
BV
C
E
:
4
9
4
3
.
5
8
150.0' VC
EV
C
S
:
1
1
+
4
3
.
5
0
EV
C
E
:
4
9
4
3
.
5
8
HIGH PT EL: 4943.79
HIGH PT STA: 10+68.50
PVI STA: 10+68.50
PVI EL: 4944.00
AD: 1.10
K: 136.35
BV
C
S
:
1
4
+
0
2
.
6
1
BV
C
E
:
4
9
4
3
.
0
1
150.0' VC
EV
C
S
:
1
5
+
5
2
.
6
1
EV
C
E
:
4
9
4
2
.
9
0
HIGH PT EL: 4943.19
HIGH PT STA: 14+68.61
PVI STA: 14+77.61
PVI EL: 4943.43
AD: 1.25
K: 120.00
150.0' VC
PVI STA: 13+24.97
PVI EL: 4942.59
AD: 1.10
K: 136.35
LOW PT EL: 4942.79
LOW PT STA: 13+24.97
BC
V
S
:
1
2
+
4
9
.
9
7
BV
C
E
:
4
9
4
3
.
0
0
EC
V
S
:
1
3
+
9
9
.
9
7
EV
C
E
:
4
9
4
3
.
0
0
150.0' VC
PVI STA: 16+55.19
PVI EL: 4942.18
AD: 1.25
K: 120.00
LOW PT EL: 4942.41
LOW PT STA: 16+64.19
BC
V
S
:
1
5
+
8
0
.
1
9
BV
C
E
:
4
9
4
2
.
7
1
EC
V
S
:
1
7
+
3
0
.
1
9
EV
C
E
:
4
9
4
2
.
5
9
0.50%-0.55%
-0.69%0.55%-0.54%
-0.50%0.50%0.54%
0.50%0.55%-0.50%
PV
I
S
T
A
=
9
+
6
6
.
7
3
PV
I
E
L
E
V
=
4
9
4
2
.
9
2
PV
I
S
T
A
=
1
1
+
6
3
.
4
2
PV
I
E
L
E
V
=
4
9
4
2
.
7
8
PV
I
S
T
A
=
1
5
+
9
6
.
5
8
PV
I
E
L
E
V
=
4
9
4
1
.
9
3
PV
I
S
T
A
=
1
8
+
1
0
.
9
4
PV
I
E
L
E
V
=
4
9
4
2
.
3
2
PV
I
S
T
A
=
1
2
+
5
7
.
1
2
PV
I
E
L
E
V
=
4
9
4
2
.
2
7
PV
I
S
T
A
=
1
3
+
2
6
.
6
5
PV
I
E
L
E
V
=
4
9
4
1
.
9
2
PVI STA = 13+96.18
PVI ELEV = 4942.27
PV
I
S
T
A
=
1
7
+
2
8
.
5
5
PV
I
E
L
E
V
=
4
9
4
1
.
8
7
PV
I
S
T
A
=
1
7
+
6
7
.
9
6
PV
I
E
L
E
V
=
4
9
4
2
.
0
8
PV
I
S
T
A
=
1
6
+
6
8
.
6
1
PV
I
E
L
E
V
=
4
9
4
1
.
5
7
BV
C
S
:
9
+
8
1
.
6
7
BV
C
E
:
4
9
4
2
.
9
9
150.0' VC
EV
C
S
:
1
1
+
3
1
.
6
7
EV
C
E
:
4
9
4
2
.
9
5
HIGH PT EL: 4943.17
HIGH PT STA: 10+53.09
PVI STA: 10+56.67
PVI EL: 4943.37
AD: 1.05
K: 142.84
BV
C
S
:
1
4
+
0
5
.
8
7
BV
C
E
:
4
9
4
2
.
3
2
150.0' VC
EV
C
S
:
1
5
+
5
5
.
8
7
EV
C
E
:
4
9
4
2
.
2
1
HIGH PT EL: 4942.50
HIGH PT STA: 14+71.74
PVI STA: 14+80.87
PVI EL: 4942.73
AD: 1.24
K: 121.39
-0.50%
-0.55%
0.55%-0.56%
-0.50%
0.50%0.55%0.56%-0.71%0.50%1.16%
PVI STA = 9+84.17
PVI ELEV = 4942.33
PV
I
S
T
A
=
1
6
+
5
9
.
7
8
PV
I
E
L
E
V
=
4
9
4
1
.
5
7
PV
I
S
T
A
=
1
1
+
6
3
.
4
3
PV
I
E
L
E
V
=
4
9
4
2
.
7
8
PV
I
S
T
A
=
1
8
+
0
2
.
1
0
PV
I
E
L
E
V
=
4
9
4
2
.
3
2
PV
I
S
T
A
=
1
2
+
5
2
.
6
9
PV
I
E
L
E
V
=
4
9
4
2
.
2
8
PV
I
S
T
A
=
1
3
+
2
3
.
2
9
PV
I
E
L
E
V
=
4
9
4
1
.
9
3
PV
I
S
T
A
=
1
7
+
2
2
.
9
3
PV
I
E
L
E
V
=
4
9
4
1
.
8
8
PV
I
S
T
A
=
1
7
+
5
9
.
1
3
PV
I
E
L
E
V
=
4
9
4
2
.
0
8
PV
I
S
T
A
=
1
5
+
8
7
.
6
0
PV
I
E
L
E
V
=
4
9
4
1
.
9
3
PVI STA = 13+93.90
PVI ELEV = 4942.28
BV
C
S
:
9
+
9
3
.
3
0
BV
C
E
:
4
9
4
2
.
4
3
150.0' VC
EV
C
S
:
1
1
+
4
3
.
3
0
EV
C
E
:
4
9
4
2
.
8
9
HIGH PT EL: 4943.02
HIGH PT STA: 10+95.05
PVI STA: 10+68.30
PVI EL: 4943.30
AD: 1.70
K: 88.09
BV
C
S
:
1
3
+
9
9
.
3
4
BV
C
E
:
4
9
4
2
.
3
1
150.0' VC
EV
C
S
:
1
5
+
4
9
.
3
4
EV
C
E
:
4
9
4
2
.
2
0
HIGH PT EL: 4942.50
HIGH PT STA: 14+65.34
PVI STA: 14+74.34
PVI EL: 4942.73
AD: 1.26
K: 118.75
FG
=
4
9
4
3
.
0
7
FG
=
4
9
4
3
.
1
7
FG
=
4
9
4
3
.
0
9
FG
=
4
9
4
2
.
8
5
FG
=
4
9
4
2
.
5
8
FG
=
4
9
4
2
.
3
1
FG
=
4
9
4
2
.
0
6
FG
=
4
9
4
2
.
0
4
FG
=
4
9
4
2
.
2
9
FG
=
4
9
4
2
.
4
8
FG
=
4
9
4
2
.
4
7
FG
=
4
9
4
2
.
2
5
FG
=
4
9
4
1
.
9
1
FG
=
4
9
4
1
.
6
6
FG
=
4
9
4
1
.
7
3
FG
=
4
9
4
1
.
9
9
FG
=
4
9
4
2
.
2
6
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
END CONSTRUCTION
END CONSTRUCTION
PROPOSED
GRADE
EXISTING
GROUND
PROPOSED
GRADE
EXISTING
GROUND
TIE INTO EXISTING CURB AND GUTTER
STA.=9+81.67
EL. = 4942.992
TIE INTO EXISTING ROADWAY
STA.=9+93.50
EL. = 4943.584
TIE INTO EXISTING CURB AND GUTTER
STA.=9+93.30
EL. = 4942.495
E
UD
UD
UD
UD
T
E
S
T
S
T
A
V
A
U
L
T
E
L
E
C
ST
E
L
E
C
F.
O
.
X
X
XX
X
X
X
X
X
X
ST
STSTST
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
6' SIDEWALK
PROPOSED
STORM DRAIN
42
'
H
A
L
F
R
O
W
52
'
F
L
-
F
L
6' SIDEWA
L
K
PROPOSED
STORM DRAIN
15' UTILITY
EASEMENT
DETENTION
POND 1
PROPOSED
STORM DRAIN
PROPOSED 30" VERTICAL
CURB & GUTTER
PROPOSED 30" VERTICAL
CURB & GUTTER
CORDOVA ROAD
12
'
S
I
D
E
W
A
L
K
CORDOV
A
R
O
A
D
DU
F
F
D
R
I
V
E
NO
R
T
H
LI
N
K
L
A
N
E
PROPOSED
BARRICADE (TYP.)
DETENTION POND 2
FUTURE
CORDOVA
R
O
A
D
NO
R
T
H
L
I
N
K
L
A
N
E
HA
L
F
R
O
W
V
A
R
I
E
S
KEYMAP
NOT TO SCALE
LI
N
E
MA
T
C
H
ST
A
19
+
0
0
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EXISTING RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
LEGEND
NOTES
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
SITE SIGN LEGEND
4B
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
A
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
19
+
0
0
C
5
1
1
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CO
R
D
O
V
A
R
O
A
D
P
L
A
N
&
P
R
O
F
I
L
E
28
1" = 40'
1" = 5'
C 510
CENTERLINE
CORDOVA ROAD
HORIZ: 1" = 40' | VERT: 1" = 5'
LEFT FLOWLINE
CORDOVA ROAD
HORIZ: 1" = 40' | VERT: 1" = 5'
RIGHT FLOWLINE
CORDOVA ROAD
HORIZ: 1" = 40' | VERT: 1" = 5'
C 5
1
0
C 51
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FUTURE
CORDOVA ROA
D
F
U
T
U
R
E
8
4
'
R
O
W
F
U
T
U
R
E
5
2
'
F
L
-
F
L
FUTURE 6' SID
E
W
A
L
K
FUTURE
14' UTILITY E
A
S
E
M
E
N
T
FUTURE 30" VERTICAL
CURB & GUTTER
FUTURE 6' SID
E
W
A
L
K
FUTURE
14' UTILITY E
A
S
E
M
E
N
T
FUTURE 30" VERTICAL
CURB & GUTTER
FUTU
R
E
CORD
O
V
A
R
O
A
D
4930
4935
4940
4945
4950
4955
4930
4935
4940
4945
4950
4955
-0.55%
0.55%-0.55%
PV
I
S
T
A
=
2
8
+
0
8
.
4
6
PV
I
E
L
E
V
=
4
9
4
0
.
7
8
EV
C
S
:
1
9
+
5
6
.
5
2
EV
C
E
:
4
9
4
3
.
0
1
150.0' VC
HP ELEV = 4941.94
HP STA = 25+59.66
PVI STA = 25+59.66
PVI ELEV = 4942.15
BV
C
S
:
2
4
+
8
4
.
6
6
BV
C
E
:
4
9
4
1
.
7
4
EV
C
S
:
2
6
+
3
4
.
6
6
EV
C
E
:
4
9
4
1
.
7
4
A.D. = 1.10
K = 136.36
150.0' VC
LOW PT ELEV = 4941.13
LOW PT STA = 23+36.88
PVI STA = 23+36.88
PVI ELEV = 4940.92
BV
C
S
:
2
2
+
6
1
.
8
8
BV
C
E
:
4
9
4
1
.
3
3
EV
C
S
:
2
4
+
1
1
.
8
8
EV
C
E
:
4
9
4
1
.
3
3
A.D. = 1.10
K = 136.36
FUTURE
GRADE
EXISTING
GROUND
FG
=
4
9
4
3
.
2
1
FG
=
4
9
4
3
.
0
5
FG
=
4
9
4
2
.
7
8
FG
=
4
9
4
2
.
5
0
FG
=
4
9
4
2
.
2
3
FG
=
4
9
4
1
.
9
5
FG
=
4
9
4
1
.
6
8
FG
=
4
9
4
1
.
4
0
FG
=
4
9
4
1
.
1
8
FG
=
4
9
4
1
.
1
3
FG
=
4
9
4
1
.
2
7
FG
=
4
9
4
1
.
5
4
FG
=
4
9
4
1
.
8
1
FG
=
4
9
4
1
.
9
4
FG
=
4
9
4
1
.
8
8
FG
=
4
9
4
1
.
6
5
FG
=
4
9
4
1
.
3
8
FG
=
4
9
4
1
.
1
0
FG
=
4
9
4
0
.
8
3
19+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50
KEYMAP
NOT TO SCALE
L
I
N
E
M
A
T
C
H
S
T
A
1
9
+
0
0
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EXISTING RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
LEGEND
NOTES
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
SITE SIGN LEGEND
4B
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
ST
A
MA
T
C
H
L
I
N
E
SE
E
S
H
E
E
T
19
+
0
0
C
5
1
0
CO
R
D
O
V
A
R
O
A
D
P
L
A
N
&
P
R
O
F
I
L
E
29
1" = 40'
1" = 5'
C 511
CENTERLINE
CORDOVA ROAD
HORIZ: 1" = 40' | VERT: 1" = 5'
C 5
1
0
C 51
1
℄
10+00
4935
4940
4945
4950
4935
4940
4945
4950
0 20 40 60 800-20-40-60-80
℄
10+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
11+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
11+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
12+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
12+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
13+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
13+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
14+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
14+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
15+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
15+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
16+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
16+50
4932
4935
4940
4945
4932
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
17+00
4932
4935
4940
4945
4932
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
17+50
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
℄
18+00
4933
4935
4940
4945
4933
4935
4940
4945
0 20 40 60 800-20-40-60-80
2.93%1.84%2.36%2.06%2.20%2.20%2.20%2.20%
2.20%2.19%2.48%2.49%2.48%2.49%
2.20%2.19%
2.21%2.19%
2.21%2.19%2.20%2.20%2.20%2.20%
2.56%2.56%2.30%2.30%
2.20%2.20%
2.20%2.20%
49
4
3
.
1
49
4
0
.
6
49
4
0
.
3
49
4
0
.
0
49
4
0
.
1
49
4
0
.
1
49
4
0
.
4
49
4
0
.
4
49
4
0
.
5
49
4
0
.
5
49
4
0
.
5
49
4
0
.
5
49
4
0
.
6
49
3
8
.
3
49
3
8
.
4
49
3
8
.
4
49
3
8
.
6
PROPOSED
GRADE
EXISTING
GROUND
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
R
O
W
PR
O
P
O
S
E
D
E
S
M
T
49
4
3
.
1
49
4
0
.
6
49
4
0
.
3
49
4
0
.
0
49
4
0
.
1
49
4
0
.
1
49
4
0
.
4
49
4
0
.
4
49
4
0
.
5
49
4
0
.
5
49
4
0
.
5
49
4
0
.
5
49
4
0
.
6
49
3
8
.
3
49
3
8
.
4
49
3
8
.
4
49
3
8
.
6
PROPOSED
STORM
HYD
T
E
S
T
S
T
A
H
2
O
V
A
U
L
T
E
L
E
C
ST
HYD
E
L
E
C
S
F.
O
.
W
X
X
XX
SS
X
X
X
X
X
X
FO
ST
STSTST
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
E
UD
UD
UD
UD
10
+
0
0
10
+
5
0
11
+
0
0
11
+
5
0
12
+
0
0
12
+
5
0
13
+
0
0
13
+
5
0
14
+
0
0
14
+
5
0
15
+
0
0
15
+
5
0
16
+
0
0
16
+
5
0
17
+
0
0
17
+
5
0
18
+
0
0
6' SIDEWALK
PROPOSED
STORM DRAIN
42
'
H
A
L
F
R
O
W
52
'
F
L
-
F
L
6' SIDEWA
L
K
15' UTILITY
EASEMENT
DETENTION
POND 1
CORDOVA ROAD
CORDOV
A
R
O
A
D
DU
F
F
D
R
I
V
E
DETENTION POND 2
NO
R
T
H
L
I
N
K
L
A
N
E
HA
L
F
R
O
W
V
A
R
I
E
S
42
'
H
A
L
F
R
O
W
HA
L
F
R
O
W
V
A
R
I
E
S
9+00 10+00 11+00 12+00 13+00
14+00
15+00
16+00
17+00
18+00
19+00
KEYMAP
NOT TO SCALE
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EXISTING RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
LEGEND
NOTES
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
SITE SIGN LEGEND
4B
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CO
R
D
O
V
A
R
O
A
D
C
R
O
S
S
-
S
E
C
T
I
O
N
S
30
1" = 40'
1" = 5'
C 512
T
E
S
T
S
T
A
V
A
U
L
T
E
L
E
C
ST
V
A
U
L
T
E
L
E
C
E
L
E
C
E
L
E
C
F.
O
.
X
X
X
XX
X
X
X
X
X
X
X
ST
STSTST
X
X
X
X
X
X
X
X
X
X
X
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
6' SIDEWALK
42
'
R
O
W
(R
O
W
V
A
R
I
E
S
)
52
'
F
L
-
F
L
6' SIDEWA
L
K
15' UTILITY
EASEMENT
DETENTION
POND 1
CORDOVA ROAD
12
'
S
I
D
E
W
A
L
K
BU
I
L
D
I
N
G
PR
O
P
O
S
E
D
DE
T
E
N
T
I
O
N
PO
N
D
2
CORDOV
A
R
O
A
D
DU
F
F
D
R
I
V
E
NO
R
T
H
L
I
N
K
L
A
N
E
PROPOSED TYPE III
BARRICADE (TYP.)
DETENTION POND 2
L
L
6
A
A
A
A
1
9
9
9
9
1
1
4
7
1
6
1
1
4
7
5
5
7 4
4
7
NO
R
T
H
L
I
N
K
L
A
N
E
5
5
5
5 1
6
6
1
42
'
H
A
L
F
R
O
W
HA
L
F
R
O
W
V
A
R
I
E
S
HA
L
F
R
O
W
V
A
R
I
E
S
KEYMAP
NOT TO SCALE
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EXISTING RIGHT-OF-WAY
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED EDGE OF ASPHALT
PROPOSED STORM MANHOLE
/ / / / / / / /
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS.
5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO
1
4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
PROPOSED STORM INLET
LEGEND
NOTES
RESERVED
PARKING
P0TS
1 2 3L 3R
4 4A
3
SITE SIGN LEGEND
4B
BIKE LANE
AHEAD ENDS
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
LANE
FIRE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
BIKE LANE BIKE LANE
6
SPEED
LIMIT
25
5
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CO
R
D
O
V
A
R
O
A
D
S
T
R
I
P
I
N
G
P
L
A
N
31
1" = 40'
N/A
C 513
YELLOW BUFFER CROSS HATCHING10
4" WHITE THERMOPLASTIC BUFFER CROSS HATCHING
4" SOLID YELLOW LINE
6" SOLID WHITE LINE
(2) 4" SOLID LINES; 4" APART
DOUBLE YELLOW LINE
4" BROKEN YELLOW LINE
8" SOLID WHITE LINE
DOUBLE YELLOW LINE
4" SOLID AND 4" BROKEN; 4" APART
9
6
3
5
1
8
2
4
7
STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
BICYCLIST AND ARROW
18" X 9' CROSSING LINE, SEE NOTES
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT MARKING
18" WIDE STOP BAR
PREFORMED PLASTIC PAVEMENT
MARKING "STOP" (22.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT MARKING
RIGHT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
LEFT TURN ARROW (15.5 S.F. EA.)
RIGHT AND LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
TWO WAY LEFT TURN ARROW (31 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
PREFORMED PLASTIC PAVEMENT
MARKING "ONLY" (22.5 S.F. EA.)
L
H
D
C
B
KA
E
F
G
I
J
M LANE REDUCTION ARROW
PREFORMED PLASTIC PAVEMENT MARKING
MEDIAN LINE YELLOW 18" WIDE1150' O.C. 45° ANGLES
10'30'10'30'10'4" BROKEN WHITE12 10'
N "LANE ENDS"
PREFORMED PLASTIC PAVEMENT MARKING
3'9'3'9'3'4" WHITE DASHED LINE
O 18" WIDE WHITE MEDIAN STRIPING
PREFORMED PLASTIC PAVEMENT MARKING
A.ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS
THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE.
B.ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED
THERMO-PLASTIC.
C.ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD.
D.ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS.
E.ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT.
F.PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE
TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE
APPROVED BY THE TOWN OF TIMNATH AND CITY OF FORT COLLINS ENGINEERS PRIOR TO PERMANENT INSTALLATION
OF STRIPING AND SYMBOLS.
G.PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS.
H.EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION.
I.ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS.
J.ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS.
K.A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT
COLLINS ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE
THE 2-YEAR WARRANTY PERIOD WILL BEGIN.
L.THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND
UTILITIES.
M.SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN.
N.SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO
INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL
SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS
SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL
FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR
ON TRAFFIC MARKINGS).
O.SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC
CONTROL DEVICES, FOR ADDITIONAL DETAIL.
P.STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE.
3'3'3'3'3'8" WHITE DASHED LINE
(NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN)
PAVEMENT STRIPING
PAVEMENT MARKINGS
STRAIGHT ARROW (15 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
30'10'30'10'
STRIPING LEGEND STRIPING NOTES
ST
ST
/ / / / / / / // / / / / / / /
CO
R
D
O
V
A
R
O
A
D
CO
R
D
O
V
A
R
O
A
D
42' HALF ROW
52' FL-FL
DUFF DRIVE
(42
.
3
8
)
(43
.
5
3
)
(43.1
4
)
42.51
43.624
3
.
0
7
43.03
42.
3
6
42.7
6
42.6843.3043.39
4
3
.
4
7
43.40
43.14
42.72
42.
6
7
43.12
0.5
%
0.
5
%
0.
3
%
0.
7
%
1.
0
%
1
.
6
%
(4.6%)(1.3%)
1.6%3.9%
43.16
4
3
.
7
9
4
3
.
0
0
2.0%2.6%
0.
5
%
0.
4
%
1.
4
%
0.
2
%
TIE INTO EXISTING CORDOVA ROAD
HALF ROW VARIES
F.O.
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
/ / / / / / / /
/ / / / / / / /
/
/
/
/
/
/
/
/
NORTH LIN
K
L
A
N
E
26'
FL-FL
42' HALF ROW
52' FL-FL
15
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
CO
R
D
O
V
A
R
O
A
D
42.32
4
3
.
0
1
42
.
9
6
42.27
4
2
.
3
2
41
.
1
0
4
0
.
8
4
4
1
.
5
6
4
1
.
8
5
42.
5
5
4
2
.
6
0
41.90
42
.
0
1
42.37
42.66
42.15
42.78
42.15
42.01
41.47 41
.
3
4
41
.
8
441.9
6
42
.
0
9
4
2
.
7
6
42.80
4
2
.
2
9
43.02 4
2
.
9
0
42.
5
9
42.27
42
.
5
742.6
9
41.96
42
.
4
8
42.4
0
41.79
4
1
.
6
5
41.21
4
1
.
0
9
4
1
.
7
1
41.83
41.59
40
.
2
7
40.21
40.96
3.
8
%
4.
2
%
2.
5
%
4.
0
%
0.
5
%
0.
4
%
0.
5
%
0.
5
%
0.
5
%
2
.
0
%
0.
6
%
0.5
%
0.
5
%
2.2%0.
6
%
2.2%
0.
6
%
0.
5
%
2.4%
2.2%
5.
0
%
2.2%
2.2%
NORTH LIN
K
L
A
N
E
HALF ROW VARIES
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
IN
T
E
R
S
E
C
T
I
O
N
D
E
T
A
I
L
S
32
1" = 20'
N/A
C 514
INTERSECTION DETAILA
CORDOVA ROAD AND DUFF DRIVE
INTERSECTION DETAILB
CORDOVA ROAD AND LINK LANE
B
A
/ / / / / / / /
/ / / / / / / /
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
W F
F
F
T
T
T
T
G G G G G G G G G G G G G G G G G G
T
FD
C
FD
C G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
S
S
FD
C
F
S
F
W
FDC
FD
C
S
S
E
E
E
E
E
W
W
S
FD
C
FDC
S
F
W
W
FDC F
VAULT
ELEC
FD
C
FD
C
S
S
E E E E E E E E E E E E E E E E E E
W
F
S
S
S
S
W
W
F
F
W
T
T
S
W T
S
U
D
UD
UD
UD
UD
UD
W
W
VAULT
ELEC
VAULT
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
E
E
T
E
E
E
E
T
VAULT
ELECE
E
E
E
E
E
E
E
E
T
E
E
T
S
S
S
S
W
W
W
W
W
W
S
T
E
EE
T
E
W
UDUD
UD
U
D
UD
UD
F
F
F
F
F
F
F
F
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
W
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
S
HYD
TEST
STAH2O
VAUL
T
ELEC
H Y D
TEST
STA
A R V
H2O
V.P.
ST
HYD
W
VAUL
T
ELEC
ELEC
ELEC
S
F.O.
W
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
XX
SS
SS
SS
X
X
X
X
X
12
"
W
12" W
E
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
E
8" W
W
G
G E
E
E
G G
12" W
EFO
12" W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W
24
"
W
STST
ST
SS
EXISTING 10"
SANITARY SEWER
(BOXELDER)
EXISTING 8" WATER
(ELCO)
CONNECT TO
EXISTING
WATER LINE
CONNECT TO
EXISTING SANITARY
SEWER MANHOLE
4' SANITARY MANHOLE (TYP.)
EXISTING
12" WATER
(ELCO)
EXISTING
24" WATER
(NWCWD)
CONNECT TO
EXISTING WATERLINE
EXISTING
ELECTRIC
EXISTING
STREET LIGHT
(TYP.)
CONNECT TO
EXISTING
STORM DRAIN
EXISTING
STORM DRAIN
EXISTING
GAS LINE
EXISTING
FIRE
HYDRANT
EXISTING
12" WATER
(ELCO)
CONNECT TO
EXISTING 12" WATERPROPOSED
POND OUTLET
STRUCTURE
PROPOSED POND OUTLET
STRUCTURE
TRANSFORMER
(TYP.)
EXISTING 8"
SANITARY SEWER
(BOXELDER)
CONNECT TO
EXISTING SANITARY
SEWER MANHOLE
PROPOSED
12" WATER
(ELCO)
EXISTING FIRE HYDRANT
TEMPORARY FIRE HYDRANT
TEMPORARY
FIRE HYDRANT
EXISTING
FIRE
HYDRANT
SANITARY
SEWER
SERVICE
(TYP.)
WATER SERVICE (TYP.)
FIRE SERVICE (TYP.)
EXISTING
STORM DRAIN
PROPOSED WATER METER (TYP.)
BLANKET DRAINAGE
& UTILITY EASEMENT
BUILDING
10
BUILDING
9
BUILDING
8
BUILDING
7
BUILDING
5
BUILDING
4
BUILDING
1
BUILDING
2
BUILDING
3
DETENTION
POND 2
DETENTION
POND 1
BUILDING
6
RAIN GARDEN D
RAIN GARDEN B
RAIN GARDEN A
RAIN GARDEN C
RAIN GARDEN M
CA
R
R
I
A
G
E
HO
U
S
E
2
CLUBHOUSE
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
GARAGE GA
R
A
G
E
GARAGE
GARAGE
GA
R
A
G
E
GARAGE
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
CO
R
D
O
V
A
R
O
A
D
LINK LANE
GA
R
A
G
E
EASEMENT EXCLUSION (TYP.)
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
CARRIAGE
HOUSE 1
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 3-3
SEE SHEET C 632
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
STORM DRAIN 4
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
STORM DRAIN 6-2
SEE SHEET C 634
STORM DRAIN 3
SEE SHEET C 631
WATER LINE 2
SEE SHEETS C 622 - C 623
WATER LINE 2
SEE SHEETS C 622 - C 623
WATER LINE 1
SEE SHEETS C 620 - C 621
WATER LINE 1
SEE SHEETS C 620 - C 621
WATER LINE 3
SEE SHEET C 624
WATER LINE 4
SEE SHEET C 625
WATER LINE 4
SEE SHEET C 625
SANITARY SEWER A
SEE SHEETS C 610 - C 612
SANITARY SEWER A5
SEE SHEET C 612
SANITARY SEWER A7
SEE SHEET C 612
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B3
SEE SHEET C 614
WATER LINE 2
SEE SHEETS C 622 - C 623 SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B2-1
SEE SHEET C 615
SANITARY SEWER B2
SEE SHEET C 615
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
30' E&BE
30' E&BE
26' EAE
10' E&BE
26' EAE
26' EAE
26' EAE
26' EAE
35' E&BE
26' EAE
26' EAE
26' EAE
35' E&BE26' EAE
30' E&BE 26' EAE
26' EAE
30' E&BE 30' EAE
30' E&BE
30' E&BE
45' E&BE
23.5' E&BE
30'
FL-FL
WATER LINE 3
SEE SHEET C 624
SANITARY SEWER A7
SEE SHEET C 612
STORM DRAIN 7
SEE SHEET C 630
FITNESS
CENTER
26' EAE 30' E&BE
METER PIT-2"Ø
METER PIT-1"Ø
SANITARY SEWER B3
SEE SHEET C 614
FIRE HYDRANT
ASSEMBLY (TYP.)
FIRE HYDRANT
ASSEMBLY (TYP.)
FIRE HYDRANT
ASSEMBLY (TYP.)
40' E&BE
FIRE HYDRANT
NORTH LIN
K
L
A
N
E
WH
I
T
E
G
O
L
D
D
R
I
V
E
DRY UTILITY PLAN
SEE SHEET C 605
STORMTECH CHAMBERS
SEE SHEETS C 510, C 634, & C 807
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
OV
E
R
A
L
L
U
T
I
L
I
T
Y
P
L
A
N
33
1" = 50'
N/A
C 600
C 601
C 602
C 603
C 604
F
T
T
FD
C
S
E
E
FDC
S
W
W
E
E
E
E
E
E
E
FDC F
VAULT
ELEC
FD
C
S
W
F
W
F
E
UD
UD
UD
UD
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
S
S
S
S
W
W
W
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
F
F
F
E
E
E
E
E
E
E
E
E
E
E
E
E
W
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
SSMH B4
SSMH B5
SSMH B3
SSMH B3-1
DOG PARK
UPSIZE SERVICE 5' AFTER METER
6" SANITARY SEWER SERVICE
TRANSFORMER
UPSIZE SERVICE 5' AFTER METER
TRANSFORMER
TRANSFORMER
FIRE HYDRANT
TRANSFORMER
4" SEWER SERVICE (TYP.
CAIRRAGE HOUSES)
GARAGE
GARAGE
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
RAIN GARDEN B
GARAGE
TRASH
ENCLOSURE
CA
R
R
I
A
G
E
HO
U
S
E
6
BUILDING
9
BUILDING
1
BUILDING
10
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
CA
R
R
I
A
G
E
HO
U
S
E
7
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
CA
R
R
I
A
G
E
HO
U
S
E
8
EASEMENT
EXCLUSION
PR
O
P
E
R
T
Y
MA
N
A
G
E
M
E
N
T
GA
R
A
G
E
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
WATER LINE 2
SEE SHEETS C 622 - C 623
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B3
SEE SHEET C 614
WATER LINE 2
SEE SHEETS C 622 - C 623
UPSIZE 5' AFTER WATER METER
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
30' E&BE
30' E&BE
30' E&BE
10' E&BE
30' E&BE
26'
FL-FL
24'
FL-FL
30' E&BE
26' PAE
11'15'
8'
8'
18'
18'
STORM DRAIN 3
SEE SHEET C 631
6" PVC SANITARY SERVICE
METER PIT-3/4"Ø
DUAL METER PIT-3/4"Ø
FIRE HYDRANT
FIRE HYDRANT
METER PIT-2"Ø
METER PIT-2"Ø
FIRE HYDRANT
METER PIT-2"Ø
TEMP. HYDRANT
REDUCER-8"X6"
4" PVC FIRE SERVICE
4" PVC FIRE SERVICE
4" PVC FIRE SERVICE
STORM DRAIN 7
SEE SHEET C 630
METER PIT-3/4"Ø
WATER SERVICE-2.5"Ø
WATER SERVICE-2.5"Ø
WATER SERVICE-1"Ø
WATER SERVICE-1"Ø
WH
I
T
E
G
O
L
D
D
R
I
V
E
26' EAE
WATER SERVICE-1"Ø
FIRE SERVICE-1"Ø
WATER SERVICE-2.5"Ø
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
6
0
2
MATCH LINE - SEE SHEET C 603
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
UT
I
L
I
T
Y
P
L
A
N
34
1" = 30'
N/A
C 601
C 601
C 602
C 603
C 604
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
F
T
E
EFD
C
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
E
E
E
E
E
E
E
E
S
E
E
E
E
E
E
E
E
E
S
FD
C
FDC
S
F
W
VAULT
ELEC
W
F
W
T
U
D
UD
UD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
E
E
E
E
E
E
E
VAULT
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
HYD
W
VAUL
T
ELEC
ELEC
ELEC
S
F.O.
X
X
X
X
XX
X
SS
SS
SS
SS
SS
X
X
X
X
X
X
X
X
8" W
8" W
8" W
W
G
G
G
E
E
E
E
E
/ / / / / / / /
/
/
/
/
/
/
/
/
NORTH LIN
K
L
A
N
E
SSMH B2-2
SSMH B2-3
SSMH B2-1
SSMH B2-1.1
SSMH B2
EX SSMH B
EXISTING 10"
SANITARY SEWER
EXISTING
ELECTRIC
EXISTING
GAS LINE
EXISTING
WATER METER
UPSIZE SERVICE 5' AFTER METER
DETENTION
POND 1
FIRE HYDRANT
TRANSFORMER
UPSIZE SERVICE
5' AFTER METER
TRANSFORMER
POND OUTLET STRUCTURE
CONNECT TO
EXISTING SSMH
CO
R
D
O
V
A
R
O
A
D
15
'
U
T
I
L
I
T
Y
EA
S
E
M
E
N
T
EXISTING
ELECTRIC VAULTELECTRIC VAULT
GARAGE
GA
R
A
G
E
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
BUILDING
1
BUILDING
2
BUILDING
3
PUBLIC STREET LIGHT (TYP.)
STORM DRAIN 3-3
SEE SHEET C 632
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 4
SEE SHEET C 630
STORM DRAIN 8
SEE SHEET C 634
WATER LINE 1
SEE SHEETS C 620 - C 621
WATER LINE 3
SEE SHEET C 624
WATER LINE 4
SEE SHEET C 625
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B2-1
SEE SHEET C 615
SANITARY SEWER B2
SEE SHEET C 615
42' ROW
52' FL-FL
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
30' E&BE
33.5' E&BE
30' E&BE
40' E&BE
26'
FL-FL
26'
FL-FL
30'
FL-FL
42' HALF ROW
52' FL-FL
26' EAE
10'
EASEMENT
EXCLUSION
UPSIZE SERVICE 5' AFTER METER
METER PIT-1.5"Ø
FIRE HYDRANT
METER PIT-2"Ø
FIRE HYDRANT
BEND-90°
TEMP. HYDRANT REDUCER-12"X6"
CONNECT TO EX. 8" PVC
4" PVC FIRE SERVICE
6" PVC FIRE SERVICE
SANITARY SEWER B1
SEE SHEET C 614
STORMTECH CHAMBERS
SEE SHEETS C 510, C 634, & C 807
WATER SERVICE-2.5"Ø
NORTH LI
N
K
L
A
N
E
26' EAE
WATER SERVICE-2.5"Ø
HALF ROW VARIES
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
6
0
1
MATCH LINE - SEE SHEET C 604
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
UT
I
L
I
T
Y
P
L
A
N
35
1" = 30'
N/A
C 602
C 601
C 602
C 603
C 604
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
W F
G G G G G G G G G G G G G G G G G G G G
T
FD
C
FD
C
E E E
F
E E E E E
S
F
W
FDC
S
W
E
E
FD
C
S
E E E E E E E E E E E E E E E E E E E
E
E
S
S
S
S
F
W
T
S
W T
S
UD
UD
UD UD
W
W
VAULT
ELEC
VAULT
ELEC
E
E
E E
E
E
E
T
E
E
EE
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
W
W
W
S
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
T
E
G
W
UD
UDUD
UD
F
F
F
F
F
E
E
E
EEEE
E
E E
E
E
E
E
E
E
E
E
E
E
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD UD
HY D
TEST
STA
A R V
H2O
V.P.
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
12" W 12" W 12" W
12
"
W
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W
NO
R
T
H
L
E
M
A
Y
A
V
E
DUFF DRIVE
SSMH A5-3
SSMH A6
SSMH A7
SSMH A5
EXISTING 12" WATER (ELCO)
EXISTING 24" WATER
(NWCWD)
EXISTING
STORM
DRAIN
UPSIZE SERVICE 5' AFTER METER
TRANSFORMER
TRANSFORMER
TRANSFORMER
TRANSFORMER
TRANSFORMER
UPSIZE SERVICE 5' AFTER METER
UPSIZE SERVICE 5' AFTER METER
CONNECT TO
EXISTING WATER
8" PVC WATER
8" PVC WATER
9' UTILITY EASEMENT
ELECTRIC
VAULT (TYP.)
UPSIZE 5' AFTER WATER METER (TYP. CARRAIGE HOUSES)
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
RAIN
GARDEN A
RAIN GARDEN M
CA
R
R
I
A
G
E
HO
U
S
E
2
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
BUILDING
8
BUILDING
5
BUILDING
7
BUILDING
4
CLUBHOUSE
FITNESS
CENTER
EASEMENT
EXCLUSION
PUBLIC STREET LIGHT (TYP.)
TRANSFORMER
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 5
SEE SHEET C 633
STORM DRAIN 3
SEE SHEET C 631
WATER LINE 2
SEE SHEETS C 622 - C 623
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER A
SEE SHEETS C 610 - C 612
SANITARY SEWER A5
SEE SHEET C 612
SANITARY SEWER A7
SEE SHEET C 612
UPSIZE 5' AFTER WATER METER
(TYP. CARRAIGE HOUSES)
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
26' EAE
24' EAE
30' E&BE
30' E&BE
30' E&BE
35' E&BE
30' E&BE
30' E&BE
30' E&BE
30' E&BE
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
24'
FL-FL
10.4'
4'
13'
13'
11'15'
15.6'
CARRIAGE
HOUSE 1
4" PVC SANITARY SERVICE
6" PVC SANITARY SERVICE
SANITARY CLEANOUT
4" PVC SANITARY SERVICE
6" PVC SANITARY SERVICE
6" PVC SANITARY SERVICE
6" PVC SANITARY SERVICE
DUAL METER PIT-3/4"Ø
METER PIT-3/4"Ø
FIRE HYDRANT
DUAL METER PIT-3/4"Ø
FIRE HYDRANT
METER PIT-1.5"Ø
METER PIT-1"Ø
METER PIT-3/4"Ø
FIRE HYDRANT
FIRE HYDRANT
METER PIT-2"Ø
4" PVC FIRE SERVICE
4" PVC FIRE SERVICE
4" PVC FIRE SERVICE
4" PVC FIRE SERVICE
METER PIT-2"Ø
LEASING
WATER SERVICE-2.5"Ø
METER PIT-2"Ø
WATER SERVICE-1.5"Ø
WATER SERVICE-1"Ø
WH
I
T
E
G
O
L
D
D
R
I
V
E
WATER SERVICE-2.5"Ø
WATER SERVICE-2.5"Ø
WATER SERVICE-1"Ø
FIRE SERVICE-1"Ø
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
6
0
4
MATCH LINE - SEE SHEET C 601
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
UT
I
L
I
T
Y
P
L
A
N
36
1" = 30'
N/A
C 603
C 601
C 602
C 603
C 604
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
F
T
G G G G G G G G G G G G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G G
E E E E
S
FD
C
S
S
W
E E E E E E E E E E E E E
E
E
EEEEEEEE
UD
UD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
UD UD
U
D
UD
UD
UD
E
E
E
E
E
E
E
E
E
E
E
E
S
HYD
TEST
STAH2O
VAUL
T
ELEC
ST
W
12
"
W
12
"
W
12
"
W
12" W
12" W
E
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12Ŕ W
EE
G G G G
12" W 12" W
E
FO
F
O
12
"
W
12" W
24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W
24
"
W
S
T
ST
ST
ST
SS SS
/ / / / / / / /
DUFF DRIVE
SSMH A3
SSMH A4
SSMH A2
SSMH A1
POND OUTLET
STRUCTURE
EXISTING 12" WATER (ELCO)
EXISTING 24" WATER (NWCWD)
EXISTING
GAS LINE
2' CONCRETE
PAN
EXISTING WATER METER
EXISTING FIBER OPTIC
EXISTING FIRE
HYDRANT
CONNECT TO
EXISTING
WATER
6" SANITARY SEWER SERVICE
PUBLIC STREET LIGHT (TYP.)
12" PVC
WATER
DETENTION
POND 2
POND OUTLET STRUCTURE
EXISTING
12" WATER
UPSIZE SERVICE 5' AFTER METER
CO
R
D
O
V
A
R
O
A
D
CONNECT TO
EXISTING SSMH
EXISTING 8"
SANITARY SEWER
EXISTING
ELECTRIC VAULT
9' UTILITY
EASEMENT
15
'
U
T
I
L
I
T
Y
EA
S
E
M
E
N
T
GARAGE
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
RAIN GARDEN D
RAIN GARDEN C
BUILDING
5
BUILDING
6
6'
S
I
D
E
W
A
L
K
GA
R
A
G
E
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
TRANSFORMER
TRANSFORMER
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 3-3
SEE SHEET C 632
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 4
SEE SHEET C 625
WATER LINE 3
SEE SHEET C 624
SANITARY SEWER A
SEE SHEET C 612
HALF ROW VARIES
52' FL-FL
26' EAE
26' EAE
30' EAE
26' EAE
30' E&BE
40' E&BE
26'
FL-FL
24'
FL-FL
42' HALF ROW
52' FL-FL
26'
FL-FL
26' EAE
4'
8'
FIRE HYDRANT
FIRE HYDRANT
METER PIT-2"Ø
SWIVEL TEE-12"X6"
CONNECT TO EX. 12" PVC
4" PVC FIRE SERVICE STORM DRAIN 3
SEE SHEET C 631
FIRE HYDRANT
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
C
6
0
3
MATCH LINE - SEE SHEET C 602
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
UT
I
L
I
T
Y
P
L
A
N
37
1" = 30'
N/A
C 604
C 601
C 602
C 603
C 604
/ / / / / / / /
/ / / / / / / /
G
G
G
G
G
G
G
G
G
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
W F
F
F
T
T
T
T
G G G G G G G G G G G G G G G G G G
T
E
FD
C
FD
C G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
S
E
E
E
E
S
FD
C
E E E
F
E E E
S
F
W
FDC
FD
C
S
S
E
E
E
E
E
W
W
S
FD
C
FDC
S
F
W
W
E
E
E
E
FDC F
VAULT
ELEC
FD
C
FD
C
S
S
E E E E E E E E E E E E E E E E E E
E
W
F
S
S
S
S
W
W
F
F
W
T
T
E
EEEEE
S
W T
S
U
D
UD
UD
UD
UD
UD
W
W
VAULT
ELEC
VAULT
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
E
E
T
E
E
E
E
E
E
E
T
E
E
E
E
E
E
VAULT
ELECE
E
E
E
E
E
E
E
E
T
E
E
EE
E
E
E
E
E
T
E
E
E
E
S
S
S
S
W
W
W
W
W
W
S
T
E
EE
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
W
UDUD
UD
U
D
UD
UD
F
F
F
F
F
F
F
F
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
W
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
S
HYD
TEST
STAH2O
VAUL
T
ELEC
H Y D
TEST
STA
A R V
H2O
V.P.
ST
HYD
W
VAUL
T
ELEC
ELEC
ELEC
S
F.O.
W
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
VAUL
T
ELEC
X
X
XX
SS
SS
SS
X
X
X
X
X
12
"
W
12" W
E
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
E
8" W
W
G
G E
E
E
G G
12" W
EFO
12" W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W 24" W
24
"
W
STST
ST
SS
EXISTING
ELECTRIC
EXISTING
STREET LIGHT
(TYP.)
EXISTING
GAS LINE
TRANSFORMER
(TYP.)
PROPOSED PUBLIC
STREET LIGHT (TYP.)
BUILDING
10
BUILDING
9
BUILDING
8
BUILDING
7
BUILDING
5
BUILDING
4
BUILDING
1
BUILDING
2
BUILDING
3
DETENTION
POND 2
DETENTION
POND 1
BUILDING
6
RAIN GARDEN D
RAIN GARDEN B
RAIN GARDEN A
RAIN GARDEN C
RAIN GARDEN M
CA
R
R
I
A
G
E
HO
U
S
E
2
CLUBHOUSE
CA
R
R
I
A
G
E
HO
U
S
E
3
CA
R
R
I
A
G
E
HO
U
S
E
4
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
GARAGE GA
R
A
G
E
GARAGE
GARAGE
GA
R
A
G
E
GARAGE
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
CO
R
D
O
V
A
R
O
A
D
NORTH LIN
K
L
A
N
E
GA
R
A
G
E
EASEMENT EXCLUSION (TYP.)
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
CARRIAGE
HOUSE 1
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
26'
FL-FL
30' E&BE
30' E&BE
26' EAE
10' E&BE
26' EAE
26' EAE
26' EAE
26' EAE
35' E&BE
26' EAE
26' EAE
26' EAE
35' E&BE26' EAE
30' E&BE 26' EAE
26' EAE
30' E&BE 30' EAE
30' E&BE
30' E&BE
45' E&BE
23.5' E&BE
30'
FL-FL
FITNESS
CENTER
26' EAE 30' E&BE
40' E&BE
NORTH LIN
K
L
A
N
E
WH
I
T
E
G
O
L
D
D
R
I
V
E
ELECTRICAL
VAULT (TYP.)
N:132762.42
E:201736.33
N:132659.53
E:201589.16
N:132467.84
E:201547.17
N:132346.75
E:201396.82
N:132509.20
E:201101.51N:132707.31
E:200747.65
N:132656.86
E:201051.88
N:132842.67
E:200833.77
N:133004.91
E:200887.18
N:132967.68
E:201818.43
N:132990.77
E:201916.13
N:133020.81
E:201860.50
N:133103.64
E:201683.24
N:133121.98
E:201384.46
N:133167.97
E:201194.34
N:133208.44
E:201050.41
N:133158.88
E:200954.93
N:133286.06
E:201510.87
N:133137.20
E:201709.71
N:133118.86
E:200977.86
N:132926.10
E:200987.45
N:132730.49
E:200919.70
PROPOSED NATURAL GAS (TYP.)
NATURAL GAS (TYP.)
ELECTRICAL MAIN RUN (TYP.)
ELECTRICAL SECONDARY RUN (TYP.)
N:132602.75
E:200935.97
N:132567.25
E:201000.08
N:132772.55
E:201233.17
N:132838.97
E:201331.47
N:132973.76
E:201464.77
KEYMAP
NOT TO SCALE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
DR
Y
U
T
I
L
I
T
Y
P
L
A
N
38
1" = 50'
N/A
C 605
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
3.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
4.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
5.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
6.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
7.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
8.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
9.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
EXISTING LOT LINE
EASEMENT LINE
G
EEXISTING ELECTRIC
EXISTING GAS
PROPERTY BOUNDARY
PROPOSED PUBLIC STREET LIGHT
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
TPROPOSED TRANSFORMER (75-500 kVA)
T
VAULT
ELECPROPOSED ELECTRICAL VAULT
PROPOSED TRANSFORMER (1,500-2,500 kVA)
G
EPROPOSED ELECTRIC (MAIN RUN)
PROPOSED GAS
EPROPOSED ELECTRIC (SECONDARY RUN)
S
HY
D
TE
S
T
ST
A
H2
O
VAU
L
T
ELE
C
S
T
W
1
2
"
W
1
2
"
W
12" W
E
12Ŕ W
E
G
G
G
12" W
12" W
E
FO
12" W
24" W
24" W
SS
SS
/ / / / / /
/
/
1
2
"
W
1
2
"
W
1
2
"
W
1
2
"
W
1
2
"
W
1
2
"
W
F
T
G
G
G
G
G
G
T
G
G
G
G
G
G
G
G
G
G
E
E
E
E
S
F
S
S
W
W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
U
D
U
D
U
D
E
E
E
E
E
E
E
E
E
STA.=18+59.04
N=132767.68
E=201251.26
SSMH A3
STA.=???
N=132299.54
E=201419.70
SSMH A1
SSMH A2
STA.=14+85.32
N=132564.82
E=201565.14
STA.=???
N=132209.56
E=201578.81
EX SSMH A
SAN SVC A3-1
INV. OUT=4938.69 (SE)
FG=4945.15
SAN SVC A2-1
INV. OUT=4937.19 (SW)
FG=4944.60
STA.=18+79.24
N=132750.72
E=201240.30
SVC WYE A3-1
SVC WYE A2-1
STA.=16+87.62
N=132674.63
E=201395.24
182.79
L
F
8
"
P
V
C
@
0
.
4
0
%
3
0
2
.
5
3
L
F
8
"
P
V
C
@
0
.
4
0
%
202.30 LF
8
"
P
V
C
@
0
.
4
0
%
20.20 LF 8" PVC @ 0.40%
28.70 LF 6" PVC @ 5.00%
24.70 LF
6" PVC
@ 8.00%
171.43 LF
8
"
P
V
C
@
0
.
4
0
%
DUFF D
R
I
V
E
C
O
R
D
O
V
A
R
O
A
D
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 4
SEE SHEET C 625
WATER LINE 3
SEE SHEET C 624STORM DRAIN 3
SEE SHEET C 631
52'
FL-FL
52'
FL-FL
52'
FL-FL 42' HALF ROW
26'
FL-FL
26'
FL-FL
1
5
'
U
T
I
L
I
T
Y
E
A
S
E
M
E
N
T
9' UTILI
T
Y
E
A
S
E
M
E
N
T
30' E&EB
23' EAE
BUILDING
5
BUILDING
4
DETENTION
POND 2
BUILDING
6
RAIN GARDEN C
G
A
R
A
G
E
GARAGE
26'
FL-FL
30' E&BE
26' EAE
STORM DRAIN 3
SEE SHEET C 631
9+50
10+00
11+00
1
2
+
0
0
1
3
+
0
0
1
4
+
0
0
15+00
16+00
17+00
18+00
1
9
+
0
0
2
0
+
0
0
21+00
S
T
A
.
LINE
MATCH
1
9
+
0
0
HALF ROW VARIES
±5" CLEARANCE
INSTALL FLOWFILL
AT CROSSING
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
3
.
6
9
FG
=
4
9
4
3
.
7
9
FG
=
4
9
4
3
.
7
1
FG
=
4
9
4
3
.
4
6
FG
=
4
9
4
3
.
1
8
FG
=
4
9
4
2
.
6
4
FG
=
4
9
3
9
.
9
0
FG
=
4
9
4
2
.
3
9
FG
=
4
9
4
2
.
9
7
FG
=
4
9
4
3
.
0
7
FG
=
4
9
4
3
.
2
6
FG
=
4
9
4
3
.
4
4
FG
=
4
9
4
3
.
8
0
FG
=
4
9
4
3
.
7
5
9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00
EX
S
S
M
H
A
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
3
9
.
3
±
IN
V
.
I
N
4
9
3
1
.
9
4
(
N
W
)
IN
V
.
O
U
T
4
9
3
1
.
8
4
(
S
E
)
182.79 LF 8" PVC @ 0.40%
SS
M
H
A
1
ST
A
1
1
+
8
2
.
7
9
RI
M
4
9
4
3
.
3
±
IN
V
.
I
N
4
9
3
2
.
8
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
2
.
6
7
(
S
E
)
302.53 LF 8" PVC @ 0.40%
202.30 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
2
-
1
ST
A
1
6
+
8
7
.
6
2
IN
V
.
I
N
4
9
3
5
.
0
9
(
N
W
)
IN
V
.
I
N
4
9
3
5
.
7
6
(
N
E
)
IN
V
.
O
U
T
4
9
3
5
.
0
9
(
S
E
)
171.43 LF 8" PVC @ 0.40%
SS
M
H
A
3
ST
A
1
8
+
5
9
.
0
4
RI
M
4
9
4
4
.
0
±
IN
V
.
I
N
4
9
3
5
.
9
7
(
S
W
)
IN
V
.
O
U
T
4
9
3
5
.
7
7
(
S
E
)
20.20 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
3
-
1
ST
A
1
8
+
7
9
.
2
4
IN
V
.
I
N
4
9
3
6
.
0
5
(
S
W
)
IN
V
.
I
N
4
9
3
6
.
7
2
(
N
W
)
IN
V
.
O
U
T
4
9
3
6
.
0
5
(
N
E
)
SS
M
H
A
2
ST
A
1
4
+
8
5
.
3
2
RI
M
4
9
4
3
.
0
±
IN
V
.
I
N
4
9
3
4
.
2
8
(
N
W
)
IN
V
.
O
U
T
4
9
3
4
.
0
8
(
S
W
)
12" PVC WATER
STA.=11+72.59
B.O.P.=4936.97
8" PVC WATER
STA.=18+49.04
B.O.P.=4937.98
15" RCP STORM
STA.=12+54.31
B.O.P.=4939.38
24" HDPE STORM
STA.=15+71.50
B.O.P.=4935.92 ±19"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
A
P
L
A
N
&
P
R
O
F
I
L
E
39
1" = 40'
N/A
C 610
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
C 610
C 611
C 612
SANITARY SEWER A
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
1
E
E
E
E
G
G
G
G
G
G
G
G
G
F
T
G
G
T
E
E
E
E
S
F W
S
S
W
W
WE
S
E
S
S
S
F
F
W
E
E
E
E
E
S
W
T
S
UD
UD
W
E
T
E
E E E
E
E
E
E
T
E
E
E
E
E
E
E
E E
E
E
E
T
E
E
EE
S
W
W
W
T
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
EE
E
E
E
F
F
F
F
E
E
E
E
E
E
E
E
E
U
D
U
D
U
D
U
D
UD
UD
U
D
U
D
U
D
U
D
STA.=???
N=133040.60
E=200882.00
SSMH A7
STA.=21+82.22
N=132698.29
E=201025.45
SSMH A5
SSMH A6
STA.=???
N=132856.58
E=201113.63
SAN SVC A7-7
INV. OUT=4941.71 (SE)
FG=4947.78
SSMH A4
STA.=20+29.91
N=132624.18
E=201158.51
SAN SVC A6-1
INV. OUT=4942.47 (SW)
FG=4947.56
SAN SVC A6-2
INV. OUT=4941.97 (NE)
FG=4947.24
SAN SVC A7-6
INV. OUT=4941.53 (SE)
FG=4947.87
SVC. WYE A7-6
STA.=27+34.16
N=133099.27
E=200928.61
SAN SVC A4-1
INV. OUT=4941.07 (NE)
FG=4946.24
SVC WYE A6-1
STA.=25+00.94
N=132942.13
E=201005.94
STA.=25+35.05
N=132963.35
E=200979.23
SVC WYE A6-2
SVC WYE A4-1
STA.=20+36.42
N=132627.35
E=201152.83
1
8
1
.
1
9
L
F
8
"
P
V
C
@
0
.
4
0
%
137.54 LF 8" PVC
@
0
.
4
0
%
74.92 LF 8" PVC @ 0.40%
6.39 LF 6" PVC @ 45.00%
33.70 LF 6" PVC @ 7.62%
7.75 LF 4" PVC @ 6.34%
7.75 LF 4" PVC @ 3.34%
20.57 LF 6" PVC @ 9.38%
1
5
0
.
6
7
L
F
8
"
P
V
C
@
0
.
4
0
%
145.80
L
F
8
"
P
V
C
@
0
.
4
0
%
124.19 LF 8" PVC
@
0
.
4
0
%
34.11 LF 8" PVC @ 0.40%
1
0
3
.
6
2
L
F
8
"
P
V
C
@
0
.
4
0
%
SVC WYE A7-7
STA.=28+37.79
N=133180.40
E=200993.07
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 1
SEE SHEETS C 620 - C 621
WATER LINE 3
SEE SHEET C 624
26'
FL-FL
BUILDING
9
BUILDING
8
BUILDING
5
BUILDING
4
BUILDING
6
C
A
R
R
I
A
G
E
H
O
U
S
E
5
G
A
R
A
G
E
GARAGE
26'
FL-FL
30' E&BE
26' EAE
30' E&BE
26' EAE
STORM DRAIN 3
SEE SHEET C 631
27.30 LF 6" PVC @ 2.00%
SVC BEND A4-1 (45° VERTICAL)
INV. IN=4940.52 (SW)
INV. OUT=4940.52 (NE)
FG=4944.90
CARRIAGE
HOUSE 3
CARRIAGE
HOUSE 4
CLUBHOUSE
FITNESS
CENTER
WATER LINE 2
SEE SHEETS C 622 - C 623
SANITARY SEWER A7
SEE SHEET C 612
STA.=20+36.42
N=132627.35
E=201152.83
SVC WYE A4-1
6.51 LF 8" PVC @ 0.41%
STORM DRAIN 7
SEE SHEET C 630
17+00
18+00
1
9
+
0
0
2
0
+
0
0
21+00
2
2
+
0
0
2
3
+
0
0
24+00
25+00
26+00
2
7
+
0
0
2
8
+
0
0
S
T
A
.
LINE
MATCH
1
9
+
0
0
CARRIAGE
HOUSE 6
S
T
A
.
LINE
MATCH
2
8
+
5
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
±19"
±24"
FG
=
4
9
4
3
.
7
5
FG
=
4
9
4
3
.
7
5
FG
=
4
9
4
3
.
9
6
FG
=
4
9
4
4
.
1
7
FG
=
4
9
4
4
.
7
5
FG
=
4
9
4
4
.
9
0
FG
=
4
9
4
5
.
1
7
FG
=
4
9
4
5
.
3
6
FG
=
4
9
4
5
.
6
7
FG
=
4
9
4
5
.
7
9
FG
=
4
9
4
5
.
4
2
FG
=
4
9
4
5
.
4
0
FG
=
4
9
4
5
.
7
0
FG
=
4
9
4
6
.
1
9
FG
=
4
9
4
6
.
6
5
FG
=
4
9
4
6
.
9
5
FG
=
4
9
4
7
.
3
5
FG
=
4
9
4
7
.
5
0
FG
=
4
9
4
7
.
9
0
FG
=
4
9
4
7
.
8
0
FG
=
4
9
4
7
.
5
1
19+0019+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00 26+50 27+00 27+50 28+00 28+50
8" PVC WATER
STA.=26+49.24
B.O.P.=4942.02
6" PVC WATER
STA.=23+29.20
B.O.P.=4940.65
8" PVC WATER
STA.=21+92.22
T.O.P.=4935.76
SS
M
H
A
5
ST
A
2
1
+
8
2
.
2
2
RI
M
4
9
4
5
.
4
±
IN
V
.
I
N
4
9
3
7
.
7
6
(
N
E
)
IN
V
.
I
N
4
9
3
7
.
7
6
(
N
W
)
IN
V
.
O
U
T
4
9
3
7
.
5
6
(
S
E
)
SS
M
H
A
7
ST
A
2
6
+
5
9
.
2
4
RI
M
4
9
4
8
.
0
±
IN
V
.
I
N
4
9
4
0
.
0
7
(
N
E
)
IN
V
.
I
N
4
9
4
0
.
0
7
(
S
W
)
IN
V
.
O
U
T
4
9
3
9
.
8
7
(
S
E
)
SS
M
H
A
4
ST
A
2
0
+
2
9
.
9
1
RI
M
4
9
4
4
.
7
±
IN
V
.
I
N
4
9
3
6
.
9
5
(
N
W
)
IN
V
.
O
U
T
4
9
3
6
.
6
5
(
N
E
)
6.51 LF 8" PVC @ 0.41%
SV
C
W
Y
E
A
4
-
1
ST
A
2
0
+
3
6
.
4
2
IN
V
.
I
N
4
9
3
6
.
9
8
(
N
W
)
IN
V
.
I
N
4
9
3
7
.
6
5
(
S
W
)
IN
V
.
O
U
T
4
9
3
6
.
9
8
(
S
E
)
145.80 LF 8" PVC @ 0.40%
181.19 LF 8" PVC @ 0.40%
SS
M
H
A
6
ST
A
2
3
+
6
3
.
4
1
RI
M
4
9
4
5
.
1
±
IN
V
.
I
N
4
9
3
8
.
6
9
(
N
W
)
IN
V
.
O
U
T
4
9
3
8
.
4
9
(
S
W
)
137.54 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
6
-
1
ST
A
2
5
+
0
0
.
9
4
IN
V
.
I
N
4
9
3
9
.
2
4
(
N
W
)
IN
V
.
I
N
4
9
3
9
.
9
0
(
N
E
)
IN
V
.
O
U
T
4
9
3
9
.
2
4
(
S
E
)
34.11 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
6
-
2
ST
A
2
5
+
3
5
.
0
5
IN
V
.
I
N
4
9
3
9
.
3
7
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
0
4
(
S
W
)
IN
V
.
O
U
T
4
9
3
9
.
3
7
(
S
E
)
124.19 LF 8" PVC @ 0.40%
74.92 LF 8" PVC @ 0.40%
SV
C
.
W
Y
E
A
7
-
6
ST
A
2
7
+
3
4
.
1
6
IN
V
.
I
N
4
9
4
0
.
3
7
(
N
E
)
IN
V
.
I
N
4
9
4
1
.
0
4
(
N
W
)
IN
V
.
O
U
T
4
9
4
0
.
3
7
(
S
W
)
103.62 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
7
ST
A
2
8
+
3
7
.
7
9
IN
V
.
I
N
4
9
4
0
.
7
9
(
N
E
)
IN
V
.
I
N
4
9
4
1
.
4
5
(
N
W
)
IN
V
.
O
U
T
4
9
4
0
.
7
9
(
S
W
)
150.67 LF 8" PVC @ 0.40%
±18"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
A
P
L
A
N
&
P
R
O
F
I
L
E
40
1" = 40'
N/A
C 611
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
C 610
C 611
C 612
SANITARY SEWER A
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
0
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
2
VAULT
ELEC
E
E
E
E
T
E
E E
E
E
T
E
E
S
S
S
S
W
W
W
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
F
F
F
E
E
E
W
UD
UD
UD
UD
UD
UD
UD
STA.=???
N=133335.23
E=201116.08
SSMH A8
SAN SVC A7-9
INV. OUT=4942.71 (SE)
FG=4948.23
SAN SVC A8
INV. OUT=4943.32 (SW)
FG=4947.84
SAN SVC A7-8
INV. OUT=4942.39 (SE)
FG=4948.44
STA.=30+29.54
N=133330.53
E=201112.35
SVC WYE A7-9
STA.=29+48.91
N=133267.41
E=201062.19
SVC WYE A7-8
7.75 LF 4" PVC @ 6.34%
7.75 LF 4" PVC @ 6.34%
83.37 LF 4" PVC @ 2.00%
111
.
1
3
L
F
8
"
P
V
C
@
0
.
4
0
%
CA
R
R
I
A
G
E
HO
U
S
E
6
GARAGE
GARAGE
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
8
10' E&BE
PR
O
P
E
R
T
Y
MA
N
A
G
E
M
E
N
T
GA
R
A
G
E
WATER LINE 2
SEE SHEETS C 622 - C 623
DOG PARK
30+
3
6
28+
0
0
29+
0
0
30+
0
0
STA
.
LI
N
E
M
A
T
C
H
28+
5
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
7
.
5
1
FG
=
4
9
4
7
.
2
9
FG
=
4
9
4
7
.
9
1
FG
=
4
9
4
8
.
2
1
FG
=
28+50 29+00 29+50 30+00 30+50
SS
M
H
A
8
ST
A
3
0
+
3
5
.
5
4
RI
M
4
9
4
8
.
0
±
IN
V
.
I
N
4
9
4
1
.
6
5
(
N
E
)
IN
V
.
O
U
T
4
9
4
1
.
5
8
(
S
W
)
80.62 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
8
ST
A
2
9
+
4
8
.
9
1
RI
M
4
9
4
2
.
3
±
IN
V
.
I
N
4
9
4
1
.
2
3
(
N
E
)
IN
V
.
I
N
4
9
4
1
.
9
0
(
N
W
)
IN
V
.
O
U
T
4
9
4
1
.
2
3
(
S
W
)
6.00 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
9
ST
A
3
0
+
2
9
.
5
4
RI
M
4
9
4
2
.
6
±
IN
V
.
I
N
4
9
4
1
.
5
5
(
N
E
)
IN
V
.
I
N
4
9
4
2
.
2
2
(
N
W
)
IN
V
.
O
U
T
4
9
4
1
.
5
5
(
S
W
)
111.13 LF 8" PVC @ 0.40%
G
G
G
G
G
G
E
E
E
W
E
E
E
T
S
E
E
E
T
E
E
E
E
U
D
UD
E
E
E
ESTA.=11+68.23
N=132780.15
E=200878.48
SSMH A5-3
SAN SVC A5-2
INV. OUT=4943.24 (NE)
FG=4946.33
SAN SVC A5-1
INV. OUT=4942.29 (SW)
FG=4946.90
SVC WYE A5-2
STA.=11+62.23
N=132777.23
E=200883.73
STA.=10+78.24
N=132736.36
E=200957.10
SVC WYE A5-1
78.
2
4
L
F
8
"
P
V
C
@
1
.
0
0
%
5.46 LF
4" PVC
@ 45.00%
5.65 LF 6" PVC @ 45.00%
6.00 LF 8" PVC @ 1.00%
11
+
0
0
STA.=10+00.00
N=132698.29
E=201025.45
SSMH A5
83
.
9
9
L
F
8
"
P
V
C
@
1
.
0
0
%
11
+
0
0
STORM DRAIN 5-2
SEE SHEET C 632
BUILDING
7
RAIN
GARDEN A
26'
FL-FL
35' E&BE
26' EAE
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 2
SEE SHEET C 633
SVC BEND A5-2 (45° VERTICAL)
INV. IN=4942.60 (SW)
INV. OUT=4942.60 (NE)
FG=4945.85
32.11 LF 6" PVC @ 2.00%
CLUBHOUSE
V.P.
W
F
G
G
E
S
S
S
S
W
W
T
E
E
E
E
E
E
E
E
E
W
W
W
S
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
F
F
F
F
E
UD
UD
UD
UD
UD
UD
UD
UD
U
D
U
D
STA.=12+37.67
N=132854.51
E=200734.15
SSMH A7-5
SAN SVC A7-1
INV. OUT=4941.37 (SE)
FG=4948.52 SAN SVC A7-2
INV. OUT=4941.70 (SE)
FG=4948.19
SAN SVC A7-3
INV. OUT=4942.11 (SE)
FG=4947.59
SAN SVC A7-4
INV. OUT=4943.89 (NE)
FG=4947.36
SVC CO A7-4
INV. IN=4943.68 (SW)
INV. OUT=4943.68 (N)
FG=4946.81
STA.=12+30.29
N=132860.29
E=200738.75
SVC WYE A7-4
STA.=12+18.95
N=132869.17
E=200745.80
SVC WYE A7-3
STA.=11+16.83
N=132949.13
E=200809.33
SVC WYE A7-2
STA.=10+36.20
N=133012.26
E=200859.48
SVC WYE A7-1
36.20 LF 8" PVC @ 0.40%
7.75 LF 4" PVC @ 8.00%
7.83 LF 4" PVC @ 8.00%
7.83 LF 4" PVC @ 8.00%
3.45 LF 4" PVC @ 45.00%
10.49 LF 4" PVC @ 2.00%
11+00
12+00
7.38 LF 8" PVC @ 0.40%
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 2
SEE SHEETS C 622 - C 623
CARRIAGE
HOUSE 2
CARRIAGE
HOUSE 3
CARRIAGE
HOUSE 4
CARRIAGE
HOUSE 1
35' E&BE
STA.=10+00.00
N=133040.60
E=200882.00
SSMH A7
SVC BEND A7-4 (45° VERTICAL)
INV. IN=4943.08 (S)
INV. OUT=4943.08 (N)
FG=4947.21
29.63 LF 4" PVC @ 2.00%
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
5
.
4
1
FG
=
4
9
4
5
.
8
7
FG
=
4
9
4
5
.
5
6
FG
=
4
9
4
5
.
8
3
10+00 10+50 11+00 11+50
78.24 LF 8" PVC @ 1.
0
0
%
SV
C
W
Y
E
A
5
-
1
ST
A
2
1
+
8
2
.
2
2
IN
V
.
I
N
4
9
3
8
.
5
5
(
N
W
)
IN
V
.
I
N
4
9
3
9
.
2
1
(
N
E
)
IN
V
.
O
U
T
4
9
3
8
.
5
5
(
S
E
)
83.99 LF 8" PVC @ 1.0
0
%
SV
C
W
Y
E
A
5
-
2
ST
A
2
1
+
8
2
.
2
2
IN
V
.
I
N
4
9
4
0
.
0
5
(
S
W
)
IN
V
.
I
N
4
9
3
9
.
3
9
(
N
W
)
IN
V
.
O
U
T
4
9
3
9
.
3
9
(
S
E
)
6.00 LF 8" PVC @ 1.00%
SS
M
H
A
5
-
3
ST
A
2
1
+
8
2
.
2
2
RI
M
4
9
4
6
.
0
±
IN
V
.
O
U
T
4
9
3
9
.
4
5
(
S
E
)
SS
M
H
A
5
ST
A
2
1
+
8
2
.
2
2
RI
M
4
9
4
5
.
4
±
IN
V
.
I
N
4
9
3
7
.
7
6
(
N
E
)
IN
V
.
I
N
4
9
3
7
.
7
6
(
N
W
)
IN
V
.
O
U
T
4
9
3
7
.
5
6
(
S
E
)
4930
4935
4940
4945
4950
4955
4960
4965
4930
4935
4940
4945
4950
4955
4960
4965
FG
=
4
9
4
7
.
6
0
FG
=
4
9
4
8
.
2
3
FG
=
4
9
4
7
.
9
4
FG
=
4
9
4
7
.
6
4
FG
=
4
9
4
7
.
4
0
FG
=
4
9
4
7
.
4
3
10+00 10+50 11+00 11+50 12+00 12+50
SS
M
H
A
7
-
5
ST
A
2
6
+
5
9
.
2
4
RI
M
4
9
4
7
.
2
±
IN
V
.
O
U
T
4
9
4
1
.
0
2
(
N
E
)
7.38 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
4
ST
A
2
6
+
5
9
.
2
4
IN
V
.
I
N
4
9
4
0
.
9
9
(
S
W
)
IN
V
.
I
N
4
9
4
1
.
5
3
(
S
)
IN
V
.
O
U
T
4
9
4
0
.
9
9
(
N
E
)
11.34 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
3
ST
A
2
6
+
5
9
.
2
4
IN
V
.
I
N
4
9
4
0
.
9
5
(
S
W
)
IN
V
.
I
N
4
9
4
1
.
4
8
(
N
W
)
IN
V
.
O
U
T
4
9
4
0
.
9
5
(
N
E
)
102.12 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
2
ST
A
2
6
+
5
9
.
2
4
IN
V
.
I
N
4
9
4
0
.
5
4
(
S
W
)
IN
V
.
I
N
4
9
4
1
.
0
8
(
N
W
)
IN
V
.
O
U
T
4
9
4
0
.
5
4
(
N
E
)
80.62 LF 8" PVC @ 0.40%
SV
C
W
Y
E
A
7
-
1
ST
A
2
6
+
5
9
.
2
4
IN
V
.
I
N
4
9
4
0
.
2
2
(
S
W
)
IN
V
.
I
N
4
9
4
0
.
7
5
(
N
W
)
IN
V
.
O
U
T
4
9
4
0
.
2
2
(
N
E
)
36.20 LF 8" PVC @ 0.40%
SS
M
H
A
7
ST
A
2
6
+
5
9
.
2
4
RI
M
4
9
4
8
.
0
±
IN
V
.
I
N
4
9
4
0
.
0
7
(
N
E
)
IN
V
.
I
N
4
9
4
0
.
0
7
(
S
W
)
IN
V
.
O
U
T
4
9
3
9
.
8
7
(
S
E
)
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
A
,
A
5
,
&
A
7
P
L
A
N
&
P
R
O
F
I
L
E
41
1" = 40'
N/A
C 612
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
A
A7
A5
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
SANITARY SEWER A
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
SANITARY SEWER A7
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
SANITARY SEWER A5
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
1
HYD
W
ELEC
S
F.O.
X
X
X
XX
X
SS
SS
X
X
8" W
8" W
W
G
G
E
E
E
/ / / /
/
/
/
/
12
"
W
12
"
W
12
"
W
F
T
E
G
G
G
G
G
G
S
E
E
E
E
E
S
E
E
E
E
E
E
E
W
E
F
VAULT
ELEC
W
F
W
T
U
D
UD
UD
E
E
E
E
E
E
E
E
E
VA
U
L
T
ELE
C
VA
U
L
T
ELE
C
E
E
E
E
VAUL
T
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
STA.=15+76.16
N=133302.68
E=201469.21
SSMH B3
SSMH B2
STA.=12+43.07
N=133095.07
E=201729.69
STA.=10+63.34
N=132983.05
E=201870.23
SSMH B1
EX SSMH B
STA.=10+00.00
N=132940.83
E=201917.46
SAN SVC B3-1
INV. OUT=4940.56 (SE)
FG=4946.67
SVC WYE B3-1
STA.=17+39.10
N=133175.09
E=201367.85
63.34 LF 10" PVC @ 0.40%
333.
0
9
L
F
8
"
P
V
C
@
0
.
4
0
%
179.
7
2
L
F
8
"
P
V
C
@
0
.
4
0
%
16
2
.
9
5
L
F
8
"
P
V
C
@
0
.
4
0
%
37.09 LF 6" PVC @ 8.00%
11+
0
0
12+0
0
13+0
0
14+0
0
15+0
0
16
+
0
0
17
+
0
0
18
+
0
0
GARAGE
RAIN
GARDEN B
BUILDING
1
BUILDING
10
BUILDING
3
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER B3
SEE SHEET C 614
30' E&BE
26'
FL-FL
26' EAE
SANITARY SEWER B1
SEE SHEET C 614
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 6
SEE SHEET C 634
SANITARY SEWER B2
SEE SHEET C 615
STORM DRAIN 8
SEE SHEET C 634
WATER LINE 2
SEE SHEETS C 622 - C 623
WATER LINE 3
SEE SHEET C 624
152.05 LF 8" PVC @ 0.40%
CO
R
D
O
V
A
R
O
A
D
NOR
T
H
L
I
N
K
L
A
N
E
WH
I
T
E
G
O
L
D
D
R
I
V
E
ST
A
.
LINE
MAT
C
H
18
+
5
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
1
.
2
5
FG
=
4
9
4
2
.
5
1
FG
=
4
9
4
2
.
4
7
FG
=
4
9
4
3
.
9
6
FG
=
4
9
4
3
.
6
6
FG
=
4
9
4
3
.
3
6
FG
=
4
9
4
3
.
5
6
FG
=
4
9
4
3
.
8
6
FG
=
4
9
4
4
.
1
6
FG
=
4
9
4
4
.
4
6
FG
=
4
9
4
4
.
7
6
FG
=
4
9
4
5
.
1
6
FG
=
4
9
4
5
.
1
6
FG
=
4
9
4
5
.
1
1
FG
=
4
9
4
4
.
8
1
FG
=
4
9
4
4
.
6
2
FG
=
4
9
4
4
.
9
2
FG
=
4
9
4
5
.
2
2
9+509+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
SS
M
H
B
2
ST
A
1
2
+
4
3
.
0
7
RI
M
4
9
4
3
.
4
±
IN
V
.
I
N
4
9
3
4
.
7
5
(
N
W
)
IN
V
.
I
N
4
9
3
4
.
7
5
(
S
W
)
IN
V
.
O
U
T
4
9
3
4
.
5
5
(
S
E
)
SS
M
H
B
1
ST
A
1
0
+
6
3
.
3
4
RI
M
4
9
4
2
.
8
±
IN
V
.
I
N
4
9
3
3
.
8
2
(
N
W
)
IN
V
.
I
N
4
9
3
3
.
8
2
(
N
E
)
IN
V
.
O
U
T
4
9
3
3
.
6
5
(
S
E
)
EX
S
S
M
H
B
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
1
.
2
±
IN
V
.
I
N
4
9
3
3
.
4
0
(
N
W
)
IN
V
.
O
U
T
4
9
3
3
.
2
0
(
S
E
)
SV
C
W
Y
E
B
3
-
1
ST
A
1
7
+
3
9
.
1
0
RI
M
4
9
3
8
.
2
±
IN
V
.
I
N
4
9
3
6
.
9
2
(
S
W
)
IN
V
.
I
N
4
9
3
7
.
5
9
(
N
W
)
IN
V
.
O
U
T
4
9
3
6
.
9
2
(
N
E
)
63.34 LF 10" PVC @ 0.40%
333.09 LF 8" PVC @ 0.40%
179.72 LF 8" PVC @ 0.40%
162.95 LF 8" PVC @ 0.40%
152.05 LF 8" PVC @ 0.40%
SS
M
H
B
3
ST
A
1
5
+
7
6
.
1
6
RI
M
4
9
4
5
.
5
±
IN
V
.
I
N
4
9
3
6
.
2
7
(
S
W
)
IN
V
.
I
N
4
9
3
6
.
2
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
6
.
0
7
(
S
E
)
8" PVC WATER
STA.=15+66.16
B.O.P.=4938.54
8" PVC WATER
STA.=15+86.16
B.O.P.=4938.60
24" RCP STORM
STA.=16+05.07
B.O.P.=4940.78
±18"±21"
12" PVC WATER
STA.=10+53.33
B.O.P.=4935.99
±18"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
B
P
L
A
N
&
P
R
O
F
I
L
E
42
1" = 40'
1" = 5'
C 613
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
C 613C 614
SANITARY SEWER B
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
4
T
E
E
E
S
E
E
E
E
E
E
E
E
E
E
E
E
E
STA.=20+41.47
N=133149.55
E=201155.57
SSMH B5
SSMH B4
STA.=18+91.15
N=133056.04
E=201273.27
SAN SVC B4-1
INV. OUT=4941.27 (NE)
FG=4947.45
SVC WYE B4-1
STA.=20+35.47
N=133145.82
E=201160.27
144.
3
2
L
F
8
"
P
V
C
@
0
.
4
0
%
28.70 LF 6" PVC @ 8.00%
18
+
0
0
19+
0
0
20+0
0
BUILDING
9
BUILDING
10
WATER LINE 1
SEE SHEETS C 620 - C 621
WH
I
T
E
G
O
L
D
D
R
I
V
E
ST
A
.
LINE
MAT
C
H
18
+
5
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
5
.
2
2
FG
=
4
9
4
5
.
2
2
FG
=
4
9
4
5
.
2
3
FG
=
4
9
4
5
.
5
7
FG
=
4
9
4
5
.
9
3
FG
=
4
9
4
6
.
2
3
FG
=
FG
=
18+5018+50 19+00 19+50 20+00 20+50 21+00 21+50
SS
M
H
B
4
ST
A
1
8
+
9
1
.
1
5
RI
M
4
9
4
5
.
1
±
IN
V
.
I
N
4
9
3
7
.
7
3
(
N
W
)
IN
V
.
O
U
T
4
9
3
7
.
5
3
(
N
E
)
SV
C
W
Y
E
B
4
-
1
ST
A
2
0
+
3
5
.
4
7
IN
V
.
I
N
4
9
3
8
.
3
1
(
N
W
)
IN
V
.
I
N
4
9
3
8
.
9
8
(
S
W
)
IN
V
.
O
U
T
4
9
3
8
.
3
1
(
S
E
)
144.32 LF 8" PVC @ 0.40%
6.00 LF 8" PVC @ 0.40%
SS
M
H
B
5
ST
A
2
0
+
4
1
.
4
7
RI
M
4
9
4
6
.
1
±
IN
V
.
O
U
T
4
9
3
8
.
3
3
(
S
E
)
H
Y D
ELEC
S
F.
O
.
X
X
XX
S
S
X
X
8
"
W
E
E
/
/
/
/
/
/
/
/
12" W
12" W
12" W
G
G
G
G
G
G
E
E
E
E
E
E
E
E
E
VAULT
ELEC
VAULT
ELEC
E
E
E
E
E
STA.=10+37.92
N=133012.74
E=201893.82
SSMH B1-1
37.92 LF 8" PVC @ 0.40%
SSMH B1
STA.=10+00.00
N=132983.05
E=201870.23
STORM DRAIN 4
SEE SHEET C 630
WATER LINE 4
SEE SHEET C 625
WATER LINE 1
SEE SHEETS C 620 - C 621
STORM DRAIN 6
SEE SHEET C 634
SANITARY SEWER B
SEE SHEETS C 613 - C 614
N
O
R
T
H
L
I
N
K
L
A
N
E
CORDOVA ROAD
N
O
R
T
H
L
I
N
K
L
A
N
E
E
E
F
VA
U
L
T
EL
E
C
W F
W
E
E
E
E
STA.=10+37.93
N=133332.38
E=201492.81
SSMH B3-1
37.93 LF 8" PVC @ 0.40%STA.=10+00.00
N=133302.68
E=201469.21
SSMH B3
WATER LINE 2
SEE SHEETS C 622 - C 623
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER B
SEE SHEETS C 613 - C 614
STORM DRAIN 6
SEE SHEET C 634
BUILDING
10
BUILDING
3
N
O
R
T
H
L
I
N
K
L
A
N
E
WHITE GOLD DR
I
V
E
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
FG
=
FG
=
4
9
4
2
.
8
1
FG
=
FG
=
9+509+50 10+00 10+50 11+00
SS
M
H
B
1
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
2
.
8
±
IN
V
.
I
N
4
9
3
3
.
8
2
(
N
W
)
IN
V
.
I
N
4
9
3
3
.
8
2
(
N
E
)
IN
V
.
O
U
T
4
9
3
3
.
6
5
(
S
E
)
SS
M
H
B
1
-
1
ST
A
1
0
+
3
7
.
9
2
RI
M
4
9
4
3
.
0
±
IN
V
.
O
U
T
4
9
3
3
.
9
7
(
S
W
)
37.92 LF 8" PVC @ 0.40%
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
FG
=
FG
=
4
9
4
5
.
5
0
FG
=
FG
=
9+509+50 10+00 10+50 11+00
37.93 LF 8" PVC @ 0.40%
SS
M
H
B
3
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
5
.
5
±
IN
V
.
I
N
4
9
3
6
.
2
7
(
S
W
)
IN
V
.
I
N
4
9
3
6
.
2
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
6
.
0
7
(
S
E
)
SS
M
H
B
3
-
1
ST
A
1
0
+
3
7
.
9
3
RI
M
4
9
4
4
.
9
±
IN
V
.
O
U
T
4
9
3
6
.
4
2
(
S
W
)
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
B
,
B
1
,
&
B
3
P
L
A
N
&
P
R
O
F
I
L
E
43
1" = 40'
1" = 5'
C 614
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
B
B3
B1
SANITARY SEWER B3
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
SANITARY SEWER B1
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
SANITARY SEWER B
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
1
3
F
T
T
E
G
G
E
E
S
E
S
F
W
E
E
E
E
E
W
T
U
D
UD
U
D
U
D
E
E
E
E
E
E
E
E
EE
E
E
E
E
E E
E
E
E
E
STA.=14+74.67
N=132958.15
E=201407.53
SSMH B2-3
SSMH B2-2
STA.=13+46.06
N=133058.85
E=201487.54
STA.=11+78.99
N=132954.92
E=201618.34
SSMH B2-1
SAN SVC B2-2
INV. OUT=4941.28 (SE)
FG=4945.67
SAN SVC B2-1
INV. OUT=4940.32 (SW)
FG=4944.63
STA.=14+68.67
N=132962.85
E=201411.26
SVC WYE B2-2
STA.=13+40.06
N=133055.12
E=201492.23
SVC WYE B2-1
178
.
9
9
L
F
8
"
P
V
C
@
0
.
4
0
%
1
6
1
.
0
7
L
F
8
"
P
V
C
@
0
.
4
0
%
122
.
6
1
L
F
8
"
P
V
C
@
0
.
4
0
%
6.03 LF 6" PVC @ 45.00%
6.22 LF 6" PVC @ 45.00%
11+
0
0
1
2
+
0
0
1
3
+
0
0
14+
0
0
SVC BEND B2-2 (45° VERTICAL)
INV. IN=4940.51 (NW)
INV. OUT=4940.51 (SE)
FG=???
38.37 LF 6" PVC @ 2.00%
SSMH B2
STA.=10+00.00
N=133095.07
E=201729.69
GARAGER
A
I
N
G
A
R
D
E
N
M
STORM DRAIN 8
SEE SHEET C 634
WATER LINE 3
SEE SHEET C 624
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B2-1
THIS SHEET-RIGHT
GARAGE
BUILDING
1
BUILDING
3
BUILDING
2
WATER LINE 1
SEE SHEETS C 620 - C 621
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 4
SEE SHEET C 630
STA
.
LI
N
E
M
A
T
C
H
18+
5
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
3
.
4
0
FG
=
4
9
4
3
.
0
7
FG
=
4
9
4
2
.
7
7
FG
=
4
9
4
2
.
6
4
FG
=
4
9
4
2
.
5
2
FG
=
4
9
4
2
.
8
2
FG
=
4
9
4
3
.
1
0
FG
=
4
9
4
3
.
4
5
FG
=
4
9
4
4
.
1
7
FG
=
4
9
4
3
.
6
3
9+509+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+0015+50
SS
M
H
B
2
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
3
.
4
±
IN
V
.
I
N
4
9
3
4
.
7
5
(
N
W
)
IN
V
.
I
N
4
9
3
4
.
7
5
(
S
W
)
IN
V
.
O
U
T
4
9
3
4
.
5
5
(
S
E
)
SS
M
H
B
2
-
1
ST
A
1
1
+
7
8
.
9
9
RI
M
4
9
4
2
.
9
±
IN
V
.
I
N
4
9
3
5
.
6
6
(
N
W
)
IN
V
.
I
N
4
9
3
5
.
6
6
(
S
W
)
IN
V
.
O
U
T
4
9
3
5
.
4
6
(
N
E
)
161.07 LF 8" PVC @ 0.40%
SS
M
H
B
2
-
2
ST
A
1
3
+
4
6
.
0
6
RI
M
4
9
4
3
.
4
±
IN
V
.
I
N
4
9
3
6
.
5
5
(
S
W
)
IN
V
.
O
U
T
4
9
3
6
.
3
3
(
S
E
)
6.00 LF 8" PVC @ 0.40%
SV
C
W
Y
E
B
2
-
1
ST
A
1
3
+
4
0
.
0
6
IN
V
.
I
N
4
9
3
6
.
3
1
(
N
W
)
IN
V
.
I
N
4
9
3
6
.
9
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
6
.
3
1
(
S
E
)
122.61 LF 8" PVC @ 0.40%
SV
C
W
Y
E
B
2
-
2
ST
A
1
4
+
6
8
.
6
7
IN
V
.
I
N
4
9
3
7
.
0
4
(
S
W
)
IN
V
.
I
N
4
9
3
7
.
7
1
(
N
W
)
IN
V
.
O
U
T
4
9
3
7
.
0
4
(
N
E
)
6.00 LF 8" PVC @ 0.40%
SS
M
H
B
2
-
3
ST
A
1
4
+
7
4
.
6
7
RI
M
4
9
4
3
.
5
±
IN
V
.
O
U
T
4
9
3
7
.
0
7
(
N
E
)
178.99 LF 8" PVC @ 0.40%
24" HDPE STORM
STA.=10+41.00
B.O.P.=4939.10
18" HDPE STORM
STA.=11+34.33
B.O.P.=4938.79
S
UD
E
E
E
E
E
SSMH B2-1.1
STA.=10+61.00
N=132907.16
E=201580.40
SAN SVC B2-1.1
INV. OUT=4939.46 (NE)
FG=4944.40
61.00 LF 8" PVC
@
0
.
4
0
%
41.32 LF 6" PVC @ 8.00%
SSMH B2-1
STA.=10+00.00
N=132954.92
E=201618.34
SANITARY SEWER B2
THIS SHEET-LEFT
BUILDING
2 GARAGE
GARAGE
STORM DRAIN 8
SEE SHEET C 634
WATER LINE 3
SEE SHEET C 624
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
2
.
8
9
FG
=
4
9
4
3
.
2
6
9+509+50 10+00 10+50 11+00
SS
M
H
B
2
-
1
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
2
.
9
±
IN
V
.
I
N
4
9
3
5
.
6
6
(
N
W
)
IN
V
.
I
N
4
9
3
5
.
6
6
(
S
W
)
IN
V
.
O
U
T
4
9
3
5
.
4
6
(
N
E
)
SS
M
H
B
2
-
1
.
1
ST
A
1
0
+
6
1
.
0
0
RI
M
4
9
4
3
.
1
±
IN
V
.
I
N
4
9
3
6
.
1
6
(
S
W
)
IN
V
.
O
U
T
4
9
3
5
.
9
1
(
N
E
)
61.00 LF 8" PVC @ 0.40%
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
SA
N
I
T
A
R
Y
S
E
W
E
R
B
2
&
B
2
-
1
P
L
A
N
&
P
R
O
F
I
L
E
44
1" = 40'
1" = 5'
C 615
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL SANITARY CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
STANDARDS & SPECIFICATIONS, CURRENT EDITION.
3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
6.ALL SANITARY SEWER SERVICES TO BE 6" PVC UNLESS OTHERWISE NOTED.
7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE.
8.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
9.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
10.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
11.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN THESE
PLANS.
12.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
13.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC RIGHT-OF-WAY
ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR REPAIRED AT NO
COST TO THE CITY.
W
EXISTING STORM SEWER
SPROPOSED SEWER SERVICE
EXISTING SANITARY SEWER SS
PROPOSED AREA STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
W
EASEMENT LINE
PROPOSED RIGHT OF WAY
PROPOSED COMBO STORM INLET
PROPOSED TYPE-R STORM INLET
PROPOSED WATER SERVICE
NOTES
LEGEND
B2-1
B2
SANITARY SEWER B2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
SANITARY SEWER B2-1
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
1
2
"
W
1
2
"
W
1
2
"
W
1
2
"
W
2
4
"
W
2
4
"
W
2
4
"
W
G
G
G
G
G
G
G
G
G
G
G
F
T
T T
G
G
G
G
G
G
G
G
T
S
E
E
E
E
S
E
E
F
E
E
E
F
W
S
E
E
E
E
E
W
S
F
W
W
E
E
E
E
E
F
VA
U
L
T
EL
E
C
S
E
E
E
E
E
E
E
E
W F
W
W
F
F
W
T
T
S
U
D
U
D
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
UD
U
D
UD
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
8" GV (NE)
12" GV (SE)
STA.=10+00.00 | OFF.=0.0'
N=132551.86
E=200955.33
TEE-12"x8"
8" GV (NE)
8" GV (SE)
STA.=11+72.05 | OFF.=0.0'
N=132702.16
E=201039.06
CROSS-8"x8"
STA.=11+08.47 | OFF.=0.0'
N=132646.62
E=201008.11
SERVICE TAP-2"Ø
4" GV (SE)
STA.=10+91.49 | OFF.=0.0'
N=132631.79
E=200999.85
TEE-8"x4"6" GV (NW)
STA.=11+38.49 | OFF.=0.0'
N=132672.85
E=201022.73
SWIVEL TEE-8"x6"
STA.=12+44.74 | OFF.=0.0' L
N=132765.67
E=201074.43
SERVICE TAP-1"Ø
STA.=13+83.87 | OFF.=0.0'
N=132883.11
E=201148.68
SERVICE TAP-2"Ø
4" GV (NW)
STA.=14+37.57 | OFF.=0.0'
N=132916.04
E=201174.81
TEE-8"x4"
8" GV (NE)
6" GV (NW)
STA.=13+08.69 | OFF.=0.0' R
N=132821.28
E=201105.98
SWIVEL TEE-8"x6"
STA.=15+31.41 | OFF.=0.0'
N=132989.52
E=201233.19
SERVICE TAP-2"Ø
4" GV (NW)
STA.=15+51.41 | OFF.=0.0'
N=133005.18
E=201245.63
TEE-8"x4"6" GV (NW)
STA.=15+91.18 | OFF.=0.0'
N=133036.32
E=201270.37
SWIVEL TEE-8"x6"
STA.=18+81.96 | OFF.=0.0'
N=133263.99
E=201451.25
SERVICE TAP-2"Ø
4" GV (NW)
STA.=18+76.96 | OFF.=0.0'
N=133260.07
E=201448.14
TEE-8"x4"
4" GV (SE)
STA.=18+22.98 | OFF.=0.0'
N=133217.81
E=201414.56
TEE-8"x4"
STA.=18+17.98 | OFF.=0.0'
N=133213.89
E=201411.45
SERVICE TAP-2"Ø
10+00
11+00
12+00
13+00
14+00
15+00
16+00
17+00
18+00
2
0
+
0
0
2
1
+
0
0
N29°07'
1
6
"
E91.49 L
F
8
"
P
V
C
16.97 LF 8" PVC
N29°07'16"E
30.02 LF 8" PVC
N29°07'16"E
33.56 LF 8" PVC
N29°07'17"E
N29°07'
1
6
"
E72.69 L
F
8
"
P
V
C
N29°07'1
5
"
E38.94 L
F
8
"
P
V
C
N38°25'52"E
42.03 LF 8" PVC
1 0 6 .0 2 L F 8 "P V C
R =6 5 0 .0 0 '
N38°28'00"E
80.35 LF 8" PVC
20.00 LF 8" PVC
N38°28'00"E
N38°28'00"E
39.77 LF 8" PVC
N38°28'00"E
158.73 LF 8" PVC
N38°28'00"E
68.06 LF 8" PVC
5.00 LF 8" PVC
N38°28'00"E
N38°28'00"E
53.98 LF 8" PVC
5.00 LF 8" PVC
N38°28'00"E
31.45 LF 8" PVC
N38°28'00"E
STA.=12+44.74 | OFF.=42.5' L
N=132786.35
E=201037.31
METER PIT-1"Ø
STA.=13+84.07 | OFF.=22.7' L
N=132897.24
E=201130.89
METER PIT-2"Ø
STA.=14+17.33 | OFF.=43.7' L
N=132927.35
E=201127.99
WATER SERVICE-2.5"Ø
STA.=11+38.49 | OFF.=40.5' L
N=132692.55
E=200987.34
FIRE HYDRANT
STA.=11+08.47 | OFF.=32.5' R
N=132630.80
E=201036.51
METER PIT-2"Ø
STA.=11+01.52 | OFF.=34.9' R
N=132623.58
E=201035.19
WATER SERVICE-2.5"Ø
STA.=12+44.74 | OFF.=53.9' L
N=132791.92
E=201027.31
WATER SERVICE-1.5"Ø
STA.=13+08.56 | OFF.=23.3' L
N=132833.30
E=201085.99
FIRE HYDRANT
STA.=15+31.41 | OFF.=42.5' L
N=133015.96
E=201199.91
METER PIT-2"Ø
STA.=15+31.41 | OFF.=49.7' L
N=133020.41
E=201194.30
WATER SERVICE-2.5"Ø
STA.=15+91.18 | OFF.=40.5' L
N=133061.51
E=201238.66
FIRE HYDRANT
STA.=18+17.98 | OFF.=50.0' R
N=133182.77
E=201450.63
WATER SERVICE-2.5"Ø
STA.=18+17.98 | OFF.=34.6' R
N=133192.39
E=201438.52
METER PIT-2"Ø
STA.=18+81.96 | OFF.=23.0' L
N=133278.30
E=201433.23
METER PIT-2"Ø STA.=18+81.96 | OFF.=74.9' L
N=133310.57
E=201392.62
WATER SERVICE-2.5"Ø
BUILDING
9BUILDING
8
BUILDING
1
BUILDING
10
BUILDING
3
BUILDING
7
BUILDING
4
BUILDING
5
BFV
EXISTING 24" WATER
(NWCWD)
UPSIZE SERVICE 5' AFTER METER
UPSIZE SERVICE
5' AFTER METER
UPSIZE SERVICE 5' AFTER METER
UPSIZE SERVICE 5'
AFTER METER
UPSIZE SERVICE 5' AFTER METER
CONNECT TO
EXISTING WATER
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSIONEASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 6
SEE SHEET C 634
WATER LINE 3
SEE SHEET C 624
SANITARY SEWER A
SEE SHEETS C 610 - C 612
SANITARY SEWER A5
SEE SHEET C 612
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B3
SEE SHEET C 614
WATER LINE 2
SEE SHEETS C 622 - C 623
SANITARY SEWER B2
SEE SHEET C 615
STORM DRAIN 3
SEE SHEET C 631
WATER LINE 3
SEE SHEET C 624
SANITARY SEWER A
SEE SHEETS C 610 - C 612
D
U
F
F
D
R
I
V
E
N
O
R
T
H
L
I
N
K
L
A
N
E
WHITE GOLD DR
I
V
E
STA.
LI
N
E
MA
T
C
H
19+00
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
24" RCP STORM
STA.=18+92.22
B.O.P.=4940.73
12" HDPE STORM
STA.=14+89.83
B.O.P.=4939.85
TO
P
=
4
9
4
0
.
8
0
TO
P
=
4
9
4
0
.
3
3
TO
P
=
4
9
3
9
.
8
7
TO
P
=
4
9
3
5
.
7
6
TO
P
=
4
9
3
9
.
5
4
TO
P
=
4
9
3
9
.
9
1
TO
P
=
4
9
4
0
.
2
9
TO
P
=
4
9
4
0
.
1
4
TO
P
=
4
9
3
9
.
8
9
TO
P
=
4
9
3
9
.
6
3
TO
P
=
4
9
3
9
.
3
8
TO
P
=
4
9
3
9
.
1
2
TO
P
=
4
9
3
8
.
8
7
TO
P
=
4
9
3
8
.
6
2
TO
P
=
4
9
3
8
.
3
6
TO
P
=
4
9
3
8
.
1
1
TO
P
=
4
9
3
8
.
4
0
TO
P
=
4
9
3
8
.
6
8
TO
P
=
4
9
3
8
.
9
7
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00
TE
E
-
1
2
"
X
8
"
ST
A
.
=
1
0
+
0
0
.
0
0
T.
O
.
P
.
=
4
9
4
0
.
8
0
TE
E
-
8
"
X
4
"
ST
A
.
=
1
0
+
9
1
.
4
9
T.
O
.
P
.
=
4
9
3
9
.
9
5
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
1
+
0
8
.
4
7
T.
O
.
P
.
=
4
9
3
9
.
7
9
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
1
+
3
8
.
4
9
T.
O
.
P
.
=
4
9
3
9
.
5
1
CR
O
S
S
-
8
"
X
8
"
ST
A
.
=
1
1
+
7
2
.
0
5
T.
O
.
P
.
=
4
9
3
5
.
7
6
SE
R
V
I
C
E
T
A
P
-
1
"
Ø
ST
A
.
=
1
2
+
4
4
.
7
4
T.
O
.
P
.
=
4
9
3
9
.
8
8
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
3
+
0
8
.
6
9
T.
O
.
P
.
=
4
9
4
0
.
3
5
TE
E
-
8
"
X
4
"
ST
A
.
=
1
4
+
3
7
.
5
7
T.
O
.
P
.
=
4
9
3
9
.
7
0
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
5
+
3
1
.
4
1
T.
O
.
P
.
=
4
9
3
9
.
2
2
TE
E
-
8
"
X
4
"
ST
A
.
=
1
5
+
5
1
.
4
1
T.
O
.
P
.
=
4
9
3
9
.
1
2
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
5
+
9
1
.
1
8
T.
O
.
P
.
=
4
9
3
8
.
9
2
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
8
+
1
7
.
9
8
T.
O
.
P
.
=
4
9
3
8
.
5
0
TE
E
-
8
"
X
4
"
ST
A
.
=
1
8
+
2
2
.
9
8
T.
O
.
P
.
=
4
9
3
8
.
5
3
TE
E
-
8
"
X
4
"
ST
A
.
=
1
8
+
7
6
.
9
6
T.
O
.
P
.
=
4
9
3
8
.
8
4
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
8
+
8
1
.
9
6
T.
O
.
P
.
=
4
9
3
8
.
8
7
8" PVC
8" PVC
8" PVC
8" PVC
ST
A
.
=
1
1
+
4
3
.
5
5
T.
O
.
P
.
=
4
9
3
9
.
4
6
45
°
B
E
N
D
ST
A
.
=
1
1
+
4
7
.
2
4
T.
O
.
P
.
=
4
9
3
5
.
7
6
45
°
B
E
N
D
ST
A
.
=
1
7
+
4
9
.
9
2
T.
O
.
P
.
=
4
9
3
8
.
1
1
1°
B
E
N
D
0.
6
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
1
+
8
5
.
7
2
T.
O
.
P
.
=
4
9
3
9
.
4
4
45
°
B
E
N
D
ST
A
.
=
1
3
+
0
8
.
6
9
T.
O
.
P
.
=
4
9
4
0
.
3
5
1°
B
E
N
D
0.
7
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
1
+
8
2
.
0
5
T.
O
.
P
.
=
4
9
3
5
.
7
6
45
°
B
E
N
D
±19"±21"
±19"
±21"
1' MJR
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
3
+
8
3
.
8
7
T.
O
.
P
.
=
4
9
3
9
.
9
7
40' MJR
5' MJR 5' MJR
35' MJR
40' MJR
8" PVC SANITARY
STA.=11+62.05
B.O.P.=4937.50
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
1
P
L
A
N
&
P
R
O
F
I
L
E
45
1" = 40'
N/A
C 620
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C
6
2
0
C 621
WATER LINE 1
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
2
1
H Y
D
W
EL
E
C
S
F.O
.
X
X
X
XX
X
SS
SS
X
X
X
8" W
8" W
W
G
G
E
E
E
/ / / / / / / /
1
2
"
W
1
2
"
W
1
2
"
W
1
2
"
W
E
G
G
G
G
G
G
E
E
E
E
E
E
E
E
E
E
E
E
F
VAULT
ELEC
W
T
UD
E
E
E
E
E
E
E
E
E
E
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
E
E
VAULT
ELEC
E
E
E
E
E
E
E
E
E
8" GV (NE)
8" GV (SE)
8" GV (NW)
STA.=19+13.41 | OFF.=0.0'
N=133288.61
E=201470.81
CROSS-8"x8"
8" GV (NW)
8" GV (SW)
STA.=22+26.50 | OFF.=0.0'
N=133093.47
E=201715.65
TEE-8"x8"
8" GV (NW)
12" GV (SW)
12" GV (NE)
STA.=24+26.24 | OFF.=0.0'
N=132968.25
E=201871.25
CROSS-12"x8"
STA.=24+32.53 | OFF.=0.0'
N=132964.33
E=201876.17
BEND-22.5°
STA.=24+82.29 | OFF.=0.0' R
N=132920.86
E=201900.13
CONNECT TO EX. 8" PVC20+00
21+00
22+00
23+00
24+00
S51°26'39"E
47.88 LF 8" PVC
S51°26'39"E
263.71 LF 8" PVC
S51°26'39"E
147.26 LF 8" PVC
6.30 LF 8" PVC
S51°26'39"E
STA.=19+61.29 | OFF.=11.0' R
N=133250.17
E=201501.40
FIRE HYDRANT
S28°
0
5
'
2
6
"
E
48.01
L
F
8
"
P
V
C
BUILDING
3
STA.=24+80.54 | OFF.=0.0'
N=132921.97
E=201898.78
BEND-22.5°
BUILDING
10
EA
S
E
M
E
N
T
EX
C
L
U
S
I
O
N
STORM DRAIN 4
SEE SHEET C 630
SANITARY SEWER B2
SEE SHEET C 615
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B1
SEE SHEET C 614
STORMTECH CHAMBERS
SEE SHEETS C 634 & C 807
STORM DRAIN 6
SEE SHEET C 634
SANITARY SEWER B3
SEE SHEET C 614
WATER LINE 2
SEE SHEETS C 622 - C 623
6" GV (SW)
STA.=19+61.29 | OFF.=0.0'
N=133258.77
E=201508.25
SWIVEL TEE-8"x6"
WATER LINE 4
SEE SHEET C 625
WATER LINE 3
SEE SHEET C 624
NORTH LINK L
A
N
E
C
O
R
D
O
V
A
R
O
A
D
NORTH LINK LA
N
E
ST
A
.
LINE
MATCH
19
+
0
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
8" PVC SANITARY
STA.=22+36.50
T.O.P.=4935.47
±20"
TO
P
=
4
9
3
8
.
9
7
TO
P
=
4
9
3
8
.
9
7
TO
P
=
4
9
3
9
.
2
6
TO
P
=
4
9
3
9
.
1
2
TO
P
=
4
9
3
8
.
8
5
TO
P
=
4
9
3
8
.
5
9
TO
P
=
4
9
3
8
.
3
3
TO
P
=
4
9
3
8
.
0
6
TO
P
=
4
9
3
7
.
8
0
TO
P
=
4
9
3
7
.
5
4
TO
P
=
4
9
3
7
.
2
7
TO
P
=
4
9
3
7
.
0
1
TO
P
=
4
9
3
6
.
3
6
19+0019+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50
8" PVC
8" PVC
8" PVC
ST
A
.
=
1
9
+
6
1
.
2
9
T.
O
.
P
.
=
4
9
3
9
.
3
2
1°
B
E
N
D
0.
6
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
2
4
+
2
6
.
2
4
T.
O
.
P
.
=
4
9
3
6
.
8
7
1°
B
E
N
D
0.
9
°
D
E
F
L
E
C
T
I
O
N
CO
N
N
E
C
T
T
O
E
X
.
8
"
P
V
C
ST
A
.
=
2
4
+
8
2
.
2
9
T.
O
.
P
.
=
4
9
3
5
.
6
6
BE
N
D
-
2
2
.
5
°
ST
A
.
=
2
4
+
3
2
.
5
3
T.
O
.
P
.
=
4
9
3
6
.
7
4
CR
O
S
S
-
1
2
"
X
8
"
ST
A
.
=
2
4
+
2
6
.
2
4
T.
O
.
P
.
=
4
9
3
6
.
8
7
TE
E
-
8
"
X
8
"
ST
A
.
=
2
2
+
2
6
.
5
0
T.
O
.
P
.
=
4
9
3
7
.
9
2
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
9
+
6
1
.
2
9
T.
O
.
P
.
=
4
9
3
9
.
3
2
CR
O
S
S
-
8
"
X
8
"
ST
A
.
=
1
9
+
1
3
.
4
1
T.
O
.
P
.
=
4
9
3
9
.
0
5
BE
N
D
-
2
2
.
5
°
ST
A
.
=
2
4
+
8
0
.
5
4
T.
O
.
P
.
=
4
9
3
5
.
7
0
10' MJR
10' MJR
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
1
P
L
A
N
&
P
R
O
F
I
L
E
46
1" = 40'
N/A
C 621
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C
6
2
0
C 621
WATER LINE 1
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
2
0
V.
P
.
VA
U
L
T
E
L
E
C
V
A
U
L
T
EL
E
C
V
A
U
L
T
EL
E
C
E
E
E
E
E
E
E
E
E
E
E
E
G
G
G
G
G
G
G
G
G
G
W
F
G
G
G
G
E
E
E
W
S
S
E
E
E
E
E
S
S
S
S
T
S
W
T
S
W
W
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
T
S
S
S
W
W
W
W
W
S
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
UD
UD
F
F
F
F
F
F
F
E
E
E
E
E
E
E
E
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
8" GV (NE)
6" GV (SE)
STA.=13+46.22 | OFF.=0.0'
N=132878.56
E=200766.03
SWIVEL TEE-8"x6"
STA.=13+42.72 | OFF.=0.0'
N=132875.82
E=200763.85
BEND-11.25°
STA.=13+79.85 | OFF.=0.0'
N=132904.89
E=200786.95
SERVICE TAP-3/4"Ø
STA.=13+24.93 | OFF.=0.0'
N=132860.27
E=200755.19
BEND-90°
STA.=12+79.56 | OFF.=0.0'
N=132838.19
E=200794.83
SERVICE TAP-3/4"Ø
8" GV (SW)
6" GV (SE)
STA.=16+81.79 | OFF.=0.0'
N=133141.30
E=200974.77
SWIVEL TEE-8"x6"
STA.=12+64.34 | OFF.=0.0'
N=132830.79
E=200808.12
SERVICE TAP-1.5"Ø
STA.=15+67.10 | OFF.=0.0'
N=133051.50
E=200903.43
SERVICE TAP-3/4"Ø
4" GV (SW)
STA.=12+59.34 | OFF.=0.0'
N=132828.36
E=200812.49
TEE-8"x4"
STA.=17+81.85 | OFF.=0.0'
N=133219.64
E=201037.02
SERVICE TAP-3/4"Ø
8" GV (NE)
8" GV (SE)
STA.=10+00.00 | OFF.=0.0'
N=132702.16
E=201039.06
CROSS-8"x8"
10
+
0
0
11
+
0
0
12
+
0
0
13
+
0
0
14+
0
0
15+
0
0
16+
0
0
17+
0
0
18+
0
0
N6
0
°
5
2
'
5
8
"
W
25
9
.
3
4
L
F
8
"
P
V
C
5.00 LF 8" PVC
N60°52'58"W 15.21 LF 8" PVC
N60°52'58"W
17.80 LF 8" PVC
N29°07'02"E
3.50 LF 8" PVC
N38°28'00"E
33.63 LF 8" PVC
N38°28'00"E
N3
8
°
2
8
'
0
0
"
E
55.
0
1
L
F
8
"
P
V
C
N3
8
°
2
8
'
0
0
"
E
100
.
0
6
L
F
8
"
P
V
C
BUILDING
9
BUILDING
8
BUILDING
7
CLUBHOUSE
FITNESS
CENTER
LEASING
CA
R
R
I
A
G
E
HO
U
S
E
2
CA
R
R
I
A
G
E
HO
U
S
E
5
CA
R
R
I
A
G
E
HO
U
S
E
6
CA
R
R
I
A
G
E
HO
U
S
E
7
CA
R
R
I
A
G
E
HO
U
S
E
1
STA.=13+46.22 | OFF.=8.0' R
N=132873.56
E=200772.32
FIRE HYDRANT
STA.=13+60.35 | OFF.=43.0' L
N=132916.37
E=200741.15
WATER SERVICE-1"Ø
STA.=13+79.85 | OFF.=43.0' L
N=132931.64
E=200753.28
DUAL METER PIT-3/4"Ø
STA.=13+94.35 | OFF.=43.0' L
N=132942.99
E=200762.30
WATER SERVICE-1"Ø
STA.=15+12.09 | OFF.=71.1' R
N=132964.22
E=200924.84
METER PIT-3/4"Ø
STA.=15+12.09 | OFF.=96.2' R
N=132948.58
E=200944.54
WATER SERVICE-1"Ø
STA.=15+43.10 | OFF.=43.0' L
N=133059.46
E=200854.83
WATER SERVICE-1"Ø
STA.=15+67.10 | OFF.=43.0' L
N=133078.25
E=200869.76
DUAL METER PIT-3/4"Ø
STA.=15+86.10 | OFF.=43.0' L
N=133093.12
E=200881.58
WATER SERVICE-1"Ø
STA.=16+81.79 | OFF.=13.5' R
N=133132.89
E=200985.35
FIRE HYDRANT
STA.=17+58.41 | OFF.=43.0' L
N=133228.04
E=200988.77
WATER SERVICE-1"Ø
STA.=18+00.85 | OFF.=43.0' L
N=133261.27
E=201015.16
WATER SERVICE-1"Ø
STA.=17+81.89 | OFF.=43.0' L
N=133246.39
E=201003.35
DUAL METER PIT-3/4"Ø
STA.=12+79.56 | OFF.=28.6' L
N=132813.20
E=200780.91
METER PIT-3/4"Ø
STA.=15+12.09 | OFF.=0.0'
N=133008.42
E=200869.21
SERVICE TAP-3/4"Ø
STA.=12+87.84 | OFF.=42.0' L
N=132805.55
E=200767.16
WATER SERVICE-1"Ø
STA.=12+64.34 | OFF.=50.1' L
N=132787.01
E=200783.73
METER PIT-1.5"Ø
STA.=12+64.34 | OFF.=70.9' L
N=132768.85
E=200773.61
WATER SERVICE-2.5"Ø
STA.=12+90.39 | OFF.=40.4' L
N=132808.17
E=200765.70
FIRE SERVICE-1"Ø
STA.=12+82.56 | OFF.=0.0'
N=132839.65
E=200792.21
FIRE SERVICE TAP-1"Ø
STA.=17+58.41 | OFF.=40.0' L
N=133226.17
E=200991.11
FIRE SERVICE-1"Ø
STA.=18+00.85 | OFF.=40.0' L
N=133259.40
E=201017.51
FIRE SERVICE-1"Ø
STA.=17+84.85 | OFF.=0.0'
N=133221.99
E=201038.88
FIRE SERVICE TAP-1"Ø
STA.=15+70.10 | OFF.=0.0'
N=133053.85
E=200905.29
FIRE SERVICE TAP-1"Ø
STA.=15+86.10 | OFF.=40.0' L
N=133091.26
E=200883.93
FIRE SERVICE-1"Ø
STA.=15+43.10 | OFF.=40.0' L
N=133057.59
E=200857.18
FIRE SERVICE-1"Ø
STA.=13+60.35 | OFF.=40.0' L
N=132914.50
E=200743.50
FIRE SERVICE-1"Ø
CA
R
R
I
A
G
E
HO
U
S
E
3
STA.=13+94.35 | OFF.=40.0' L
N=132941.12
E=200764.65
FIRE SERVICE-1"Ø
N3
8
°
2
8
'
0
0
"
E
111
.
6
9
L
F
8
"
P
V
C
3.00 LF 8" PVC
N38°28'00"E
3.00 LF 8" PVC
N38°24'29"E
N3
8
°
2
8
'
0
0
"
E
129
.
2
4
L
F
8
"
P
V
C
3.00 LF 8" PVC
N38°28'00"E
STA.=13+82.85 | OFF.=0.0'
N=132907.24
E=200788.81
FIRE SERVICE TAP-1"Ø
CA
R
R
I
A
G
E
HO
U
S
E
4
3.00 LF 8" PVC
N60°52'58"W
NO
R
T
H
L
E
M
A
Y
A
V
E
WHIT
E
G
O
L
D
D
R
I
V
E
UPSIZE 5' AFTER WATER METER
(TYP. CARRAIGE HOUSES)
EASEMENT
EXCLUSION
EASEMENT EXCLUSION
(TYP. CARRIAGE HOUSES)
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
STORM DRAIN 5-2
SEE SHEET C 632
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER A
SEE SHEETS C 610 - C 612
SANITARY SEWER A5
SEE SHEET C 612
SANITARY SEWER A7
SEE SHEET C 612
STORM DRAIN 7
SEE SHEET C 630
STORM DRAIN 3
SEE SHEET C 631
SANITARY SEWER A
SEE SHEETS C 610 - C 612
ST
A
.
LIN
E
MA
T
C
H
19+
0
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
TO
P
=
4
9
3
5
.
7
6
TO
P
=
4
9
3
9
.
9
8
TO
P
=
4
9
4
0
.
3
5
TO
P
=
4
9
4
0
.
7
1
TO
P
=
4
9
4
1
.
0
8
TO
P
=
4
9
4
1
.
4
5
TO
P
=
4
9
4
1
.
8
2
TO
P
=
4
9
4
2
.
1
7
TO
P
=
4
9
4
2
.
3
1
TO
P
=
4
9
4
2
.
4
5
TO
P
=
4
9
4
2
.
5
9
TO
P
=
4
9
4
2
.
7
4
TO
P
=
4
9
4
2
.
8
8
TO
P
=
4
9
4
3
.
0
2
TO
P
=
4
9
4
2
.
8
9
TO
P
=
4
9
4
2
.
2
7
TO
P
=
4
9
4
1
.
6
5
TO
P
=
4
9
4
1
.
3
4
TO
P
=
4
9
4
1
.
1
7
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00
8" PVC
8" PVC 8" PVC
8" PVC
ST
A
.
=
1
0
+
1
5
.
0
0
T.
O
.
P
.
=
4
9
3
5
.
7
6
45
°
B
E
N
D
ST
A
.
=
1
0
+
1
8
.
9
9
T.
O
.
P
.
=
4
9
3
9
.
7
5
45
°
B
E
N
D
ST
A
.
=
1
3
+
4
6
.
2
2
T.
O
.
P
.
=
4
9
4
2
.
1
6
0°
B
E
N
D
0.
3
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
6
+
8
1
.
7
9
T.
O
.
P
.
=
4
9
4
3
.
1
1
1°
B
E
N
D
0.
9
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
8
+
1
5
.
8
6
T.
O
.
P
.
=
4
9
4
1
.
4
5
1°
B
E
N
D
0.
5
°
D
E
F
L
E
C
T
I
O
N
CR
O
S
S
-
8
"
X
8
"
ST
A
.
=
1
0
+
0
0
.
0
0
T.
O
.
P
.
=
4
9
3
5
.
7
6
TE
E
-
8
"
X
4
"
ST
A
.
=
1
2
+
5
9
.
3
4
T.
O
.
P
.
=
4
9
4
1
.
5
2
SE
R
V
I
C
E
T
A
P
-
1
.
5
"
Ø
ST
A
.
=
1
2
+
6
4
.
3
4
T.
O
.
P
.
=
4
9
4
1
.
5
5
SE
R
V
I
C
E
T
A
P
-
3
/
4
"
Ø
ST
A
.
=
1
2
+
7
9
.
5
6
T.
O
.
P
.
=
4
9
4
1
.
6
7
BE
N
D
-
1
1
.
2
5
°
ST
A
.
=
1
3
+
4
2
.
7
2
T.
O
.
P
.
=
4
9
4
2
.
1
3
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
3
+
4
6
.
2
2
T.
O
.
P
.
=
4
9
4
2
.
1
6
SE
R
V
I
C
E
T
A
P
-
3
/
4
"
Ø
ST
A
.
=
1
3
+
7
9
.
8
5
T.
O
.
P
.
=
4
9
4
2
.
2
5
SE
R
V
I
C
E
T
A
P
-
3
/
4
"
Ø
ST
A
.
=
1
5
+
6
7
.
1
0
T.
O
.
P
.
=
4
9
4
2
.
7
8
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
6
+
8
1
.
7
9
T.
O
.
P
.
=
4
9
4
3
.
1
1
SE
R
V
I
C
E
T
A
P
-
3
/
4
"
Ø
ST
A
.
=
1
7
+
8
1
.
8
5
T.
O
.
P
.
=
4
9
4
1
.
8
7
±18"
8" PVC SANITARY
STA.=10+10.00
B.O.P.=4937.78
±24"
40' MJR
5' MJR
15' MJR
3' MJR
3' MJR
FI
R
E
S
E
R
V
I
C
E
T
A
P
-
1
"
Ø
ST
A
.
=
1
3
+
8
2
.
8
5
T.
O
.
P
.
=
4
9
4
2
.
2
6
FI
R
E
S
E
R
V
I
C
E
T
A
P
-
1
"
Ø
ST
A
.
=
1
2
+
8
2
.
5
6
T.
O
.
P
.
=
4
9
4
1
.
6
9
FI
R
E
S
E
R
V
I
C
E
T
A
P
-
1
"
Ø
ST
A
.
=
1
5
+
7
0
.
1
0
T.
O
.
P
.
=
4
9
4
2
.
7
9
FI
R
E
S
E
R
V
I
C
E
T
A
P
-
1
"
Ø
ST
A
.
=
1
7
+
8
4
.
8
5
T.
O
.
P
.
=
4
9
4
1
.
8
3
4" PVC SANITARY
STA.=10+88.24
B.O.P.=4941.75
±18"
8" PVC SANITARY
STA.=15+45.24
T.O.P.=4940.52
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
2
P
L
A
N
&
P
R
O
F
I
L
E
47
1" = 40'
N/A
C 622
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
C
6
2
2
C
6
2
3
WATER LINE 2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
2
3
S
E
E
F
VAULT
ELEC
W
F
W
UD
UD
E
E
E
E
E
E
E
E
E
E
S
S
W
E
E
E
F
W
UD
UD
UD
UD
UD
UD
STA.=19+50.31 | OFF.=0.0'
N=133351.54
E=201141.81
SERVICE TAP-3/4"Ø6" GV (SE)
8" GV (NE)
STA.=19+18.37 | OFF.=0.0'
N=133326.53
E=201121.94
SWIVEL TEE-8"x6"
STA.=19+97.45 | OFF.=0.0'
N=133396.76
E=201142.08
SERVICE TAP-3/4"Ø
STA.=20+23.72 | OFF.=0.0'
N=133422.85
E=201139.08
BEND-45°
8" GV (NE)
8" GV (SE)
STA.=21+25.50 | OFF.=0.0'
N=133502.55
E=201202.40
TEE-8"x8"
8" GV (NE)
8" GV (SE)
8" GV (NW)
STA.=24+68.74 | OFF.=0.0'
N=133288.61
E=201470.81
CROSS-8"x8"
STA.=25+10.69 | OFF.=0.0'
N=133321.46
E=201496.91
REDUCER-8"x6"
8" GV (SW)
STA.=25+16.69 | OFF.=0.0'
N=133326.16
E=201500.64
TEMP. HYDRANT
21
+
0
0
22+00
23+00
24+00
25
+
0
0
STA.=20+05.18 | OFF.=14.0' R
N=133406.03
E=201155.10
METER PIT-3/4"Ø
STA.=20+07.77 | OFF.=16.6' R
N=133408.90
E=201157.38
WATER SERVICE-1"Ø
BUILDING
10
CA
R
R
I
A
G
E
HO
U
S
E
8
STA.=19+18.25 | OFF.=85.8' R
N=133273.06
E=201189.06
FIRE HYDRANT
STA.=19+73.51 | OFF.=31.4' L
N=133369.40
E=201113.63
WATER SERVICE-1"Ø
STA.=19+50.31 | OFF.=15.0' L
N=133360.87
E=201130.06
METER PIT-3/4"Ø
31.94 LF 8" PVC
N38°28'00"E
47.20 LF 8" PVC
N06°32'56"W
18.54 LF 8" PVC
N06°32'56"W
N3
8
°
2
8
'
0
0
"
E
61
.
7
9
L
F
8
"
P
V
C
S51°26'39"
E
343.24 LF
8
"
P
V
C
47.95 LF 8" PVC
N38°28'00"E
STA.=19+76.51 | OFF.=31.4' L
N=133372.38
E=201113.32
FIRE SERVICE-1"Ø
STA.=19+53.31 | OFF.=0.0'
N=133353.89
E=201143.67
FIRE SERVICE TAP-1"Ø
3.00 LF 8" PVC
N38°28'00"E
4.68 LF 8" PVC
N38°28'00"E
WH
I
T
E
G
O
L
D
D
R
I
V
E
EASEMENT
EXCLUSION
STORM DRAIN 6
SEE SHEET C 634
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B3
SEE SHEET C 614
STA.=19+57.98 | OFF.=0.0'
N=133357.55
E=201146.58
BEND-45°
ST
A
.
LINE
MATCH
19
+
0
0
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
TO
P
=
4
9
4
1
.
1
7
TO
P
=
4
9
4
1
.
1
7
TO
P
=
4
9
4
1
.
0
1
TO
P
=
4
9
4
0
.
8
4
TO
P
=
4
9
4
0
.
6
7
TO
P
=
4
9
4
0
.
5
1
TO
P
=
4
9
4
0
.
3
4
TO
P
=
4
9
4
0
.
1
8
TO
P
=
4
9
4
0
.
0
1
TO
P
=
4
9
3
9
.
8
4
TO
P
=
4
9
3
9
.
6
8
TO
P
=
4
9
3
9
.
5
1
TO
P
=
4
9
3
9
.
3
5
TO
P
=
4
9
3
9
.
1
8
19+0019+00 19+50 20+00 20+50 21+00 21+50 22+00 22+50 23+00 23+50 24+00 24+50 25+00 25+50 26+00
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
9
+
1
8
.
3
7
T.
O
.
P
.
=
4
9
4
1
.
1
1
SE
R
V
I
C
E
T
A
P
-
3
/
4
"
Ø
ST
A
.
=
1
9
+
5
0
.
3
1
T.
O
.
P
.
=
4
9
4
1
.
0
0
BE
N
D
-
4
5
°
ST
A
.
=
1
9
+
5
7
.
9
8
T.
O
.
P
.
=
4
9
4
0
.
9
8
BE
N
D
-
4
5
°
ST
A
.
=
2
0
+
2
3
.
7
2
T.
O
.
P
.
=
4
9
4
0
.
7
6
TE
E
-
8
"
X
8
"
ST
A
.
=
2
1
+
2
5
.
5
0
T.
O
.
P
.
=
4
9
4
0
.
4
2
CR
O
S
S
-
8
"
X
8
"
ST
A
.
=
2
4
+
6
8
.
7
4
T.
O
.
P
.
=
4
9
3
9
.
2
8
8" PVC
RE
D
U
C
E
R
-
8
"
X
6
"
ST
A
.
=
2
5
+
1
0
.
6
9
T.
O
.
P
.
=
4
9
3
9
.
1
5
TE
M
P
.
H
Y
D
R
A
N
T
ST
A
.
=
2
5
+
1
6
.
6
9
T.
O
.
P
.
=
4
9
3
9
.
1
3
8" PVC SANITARY
STA.=24+58.74
T.O.P.=4937.00
±19"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
2
P
L
A
N
&
P
R
O
F
I
L
E
48
1" = 40'
N/A
C 623
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
C
6
2
2
C
6
2
3
WATER LINE 2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
MA
T
C
H
LI
N
E
SE
E
S
H
E
E
T
C
6
2
0
G
G
G
G
G
F
F
T
T T
T
E
E
E
E
E
E
S
E
E
E
E
S
F
S
S
E
E
E
E
E
E
E
W
W
S
S
F
W
E
E
E
E
E
W F
W
T
E
E
E
E
UD
UD
U
D
U
D
T
E
E
E
E
E
E
VA
U
L
T
EL
E
C
U
D
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
8" GV (NE)
8" GV (SE)
STA.=10+00.00 | OFF.=0.0' L
N=132702.16
E=201039.06
CROSS-8"x8"
4" GV (NE)
STA.=10+84.00 | OFF.=0.0'
N=132661.29
E=201112.44
TEE-8"x4"
STA.=11+16.50 | OFF.=0.0'
N=132645.47
E=201140.83
SERVICE TAP-2"Ø
STA.=11+54.11 | OFF.=0.0'
N=132627.17
E=201173.69
BEND-90°
6" GV (SE)
8" GV (NE)
STA.=11+66.59 | OFF.=0.0'
N=132638.05
E=201179.80
SWIVEL TEE-8"x6"
6" GV (NW)
STA.=15+84.91 | OFF.=0.0'
N=132983.64
E=201415.01
SWIVEL TEE-8"x6"
STA.=16+63.14 | OFF.=0.0'
N=133044.89
E=201463.67
SERVICE TAP-1.5"Ø
6" GV (NW)
STA.=16+53.80 | OFF.=0.0'
N=133037.57
E=201457.86
TEE-8"x4"
4" GV (SE)
STA.=15+50.31 | OFF.=0.0'
N=132956.54
E=201393.48
TEE-8"x4"
STA.=16+98.92 | OFF.=0.0'
N=133072.90
E=201485.93
BEND-90°
STA.=18+65.99 | OFF.=0.0'
N=132968.97
E=201616.73
BEND-90°
STA.=13+50.51 | OFF.=0.0' L
N=132792.71
E=201279.34
SERVICE TAP-2"Ø
4" GV (SE)
STA.=13+82.82 | OFF.=0.0'
N=132819.84
E=201296.88
TEE-8"x4"
STA.=11+16.50 | OFF.=13.0' L
N=132656.83
E=201147.16
METER PIT-2"Ø
BUILDING
1
BUILDING
2
BUILDING
3
BUILDING
6
BUILDING
4
STA.=11+66.02 | OFF.=17.5' R
N=132628.99
E=201194.78
FIRE HYDRANT
STA.=13+35.36 | OFF.=21.0' R
N=132768.57
E=201288.77
FIRE HYDRANT
STA.=13+74.82 | OFF.=38.1' R
N=132792.42
E=201324.57
WATER SERVICE-2.5"Ø
STA.=15+59.81 | OFF.=43.6' R
N=132936.87
E=201433.52
WATER SERVICE-2.5"Ø
STA.=15+95.75 | OFF.=24.1' R
N=132977.11
E=201440.64
METER PIT-2"Ø
STA.=16+63.14 | OFF.=19.3' L
N=133056.89
E=201448.56
METER PIT-1.5"Ø
STA.=16+56.96 | OFF.=61.4' L
N=133078.23
E=201411.77
WATER SERVICE-2.5"Ø
STA.=15+84.91 | OFF.=11.0' L
N=132990.48
E=201406.40
FIRE HYDRANT
STA.=15+95.75 | OFF.=0.0'
N=132992.12
E=201421.75
SERVICE TAP-2"Ø
STA.=13+50.51 | OFF.=17.0' R
N=132783.48
E=201293.62
METER PIT-2"Ø
1
0
+
0
0
1
1
+
0
0
12+00
13+00
14+00
15+00 16+00
1
8
+
0
0
19+00
20+00
8" GV (NW)
8" GV (SW)
STA.=20+24.99 | OFF.=0.0'
N=133093.47
E=201715.65
TEE-8"x8"
STA.=18+45.35 | OFF.=11.8' L
N=132991.07
E=201607.93
FIRE HYDRANT
6" GV (NW)
8" GV (SW)
STA.=18+77.81 | OFF.=0.0'
N=132978.23
E=201624.09
SWIVEL TEE-8"x6"
BUILDING
5
UPSIZE SERVICE
5' AFTER METER (TYP.)
EASEMENT
EXCLUSION
EASEMENT
EXCLUSION
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 5
SEE SHEET C 633
WATER LINE 1
SEE SHEETS C 620 - C 621 WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER A5
SEE SHEET C 612
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER B2-1
SEE SHEET C 615
SANITARY SEWER B2
SEE SHEET C 615
SANITARY SEWER A
SEE SHEET C 612
STORM DRAIN 3
SEE SHEET C 631 STORMTECH CHAMBERS
SEE SHEETS C 634 & C 807
STORM DRAIN 6-2
SEE SHEET C 634
WATER LINE 2
SEE SHEETS C 622 - C 623
N
O
R
T
H
L
I
N
K
L
A
N
E
WHITE G
O
L
D
D
R
I
V
E
5'
5'
5'
S
6
0
°
5
2
'
5
8
"
E
8
4
.
0
0
L
F
8
"
P
V
C
32.50 LF 8" PVC
S60°52'58"E
12.48 LF 8" PVC
N29°19'34"E
N32°52'33
"
E154.32 LF
8
"
P
V
C
15.16 LF 8" PVC
N32°52'30"E
32.30 LF 8" PVC
N32°52'30"E
37.88 LF 8" PVC
N32°52'32"E
1 1 7 .1 0 L F 8 "P V C
R =1 2 0 0 .0 0 '
8" GV (SW)
6" GV (SE)
STA.=13+35.36 | OFF.=0.0' L
N=132779.98
E=201271.12
SWIVEL TEE-8"x6"
34.61 LF 8" PVC
N38°28'00"E
10.84 LF 8" PVC
N38°28'00"E
N38°28'00"E
58.05 LF 8" PVC
9.34 LF 8" PVC
N38°28'00"E
35.78 LF 8" PVC
N38°28'00"E
S
5
1
°
3
2
'
0
0
"
E
1
6
7
.
0
7
L
F
8
"
P
V
C
N38°28'00"E
147.19 LF 8" PVC
11.82 LF 8" PVC
N38°28'00"E
STA.=10+89.63 | OFF.=33.9' L
N=132688.18
E=201133.87
WATER SERVICE-2.5"Ø
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
8" PVC SANITARY
STA.=11+42.96
T.O.P.=4937.30
8" PVC SANITARY
STA.=13+14.25
T.O.P.=4936.42
6" PVC SANITARY
STA.=17+14.92
B.O.P.=4939.75
6" PVC SANITARY
STA.=15+66.31
B.O.P.=4940.57
18" HDPE STORM
STA.=18+97.65
B.O.P.=4938.84
24" HDPE STORM
STA.=19+93.99
B.O.P.=4939.15±18"
±19"
±18"
±22"
TO
P
=
4
9
3
5
.
7
6
TO
P
=
4
9
3
9
.
2
0
TO
P
=
4
9
3
9
.
3
6
TO
P
=
4
9
3
9
.
5
3
TO
P
=
4
9
3
9
.
3
8
TO
P
=
4
9
3
9
.
0
7
TO
P
=
4
9
3
8
.
7
7
TO
P
=
4
9
3
8
.
5
0
TO
P
=
4
9
3
8
.
3
0
TO
P
=
4
9
3
8
.
0
0
TO
P
=
4
9
3
8
.
3
4
TO
P
=
4
9
3
8
.
6
8
TO
P
=
4
9
3
8
.
8
4
TO
P
=
4
9
3
8
.
5
9
TO
P
=
4
9
3
8
.
3
4
TO
P
=
4
9
3
8
.
0
9
TO
P
=
4
9
3
7
.
8
4
TO
P
=
4
9
3
7
.
5
9
TO
P
=
4
9
3
7
.
4
4
TO
P
=
4
9
3
7
.
5
5
TO
P
=
4
9
3
7
.
7
0
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00
8" PVC
8" PVC 8" PVC
8" PVC
8" PVC 8" PVC
8" PVC
ST
A
.
=
1
3
+
3
5
.
3
6
T.
O
.
P
.
=
4
9
3
8
.
5
6
0°
B
E
N
D
0.
1
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
4
+
3
1
.
4
0
T.
O
.
P
.
=
4
9
3
8
.
1
7
45
°
B
E
N
D
ST
A
.
=
1
4
+
3
3
.
2
7
T.
O
.
P
.
=
4
9
3
6
.
3
0
45
°
B
E
N
D
ST
A
.
=
1
4
+
4
3
.
2
7
T.
O
.
P
.
=
4
9
3
6
.
3
0
45
°
B
E
N
D
ST
A
.
=
1
4
+
4
4
.
9
4
T.
O
.
P
.
=
4
9
3
7
.
9
7
45
°
B
E
N
D
ST
A
.
=
1
5
+
8
4
.
9
1
T.
O
.
P
.
=
4
9
3
8
.
9
2
1°
B
E
N
D
0.
7
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
0
+
1
0
.
0
0
T.
O
.
P
.
=
4
9
3
5
.
7
6
45
°
B
E
N
D
ST
A
.
=
1
0
+
1
3
.
3
2
T.
O
.
P
.
=
4
9
3
9
.
0
8
45
°
B
E
N
D
ST
A
.
=
1
1
+
6
6
.
5
9
T.
O
.
P
.
=
4
9
3
9
.
5
8
1°
B
E
N
D
0.
5
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
9
+
9
3
.
9
9
T.
O
.
P
.
=
4
9
3
7
.
6
5
0°
B
E
N
D
0.
4
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
8
+
8
6
.
4
9
T.
O
.
P
.
=
4
9
3
7
.
4
1
0°
B
E
N
D
0.
4
°
D
E
F
L
E
C
T
I
O
N
CR
O
S
S
-
8
"
X
8
"
ST
A
.
=
1
0
+
0
0
.
0
0
T.
O
.
P
.
=
4
9
3
5
.
7
6
TE
E
-
8
"
X
4
"
ST
A
.
=
1
0
+
8
4
.
0
0
T.
O
.
P
.
=
4
9
3
9
.
3
1
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
1
+
1
6
.
5
0
T.
O
.
P
.
=
4
9
3
9
.
4
2
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
1
+
6
6
.
5
9
T.
O
.
P
.
=
4
9
3
9
.
5
8
BE
N
D
-
9
0
°
ST
A
.
=
1
1
+
5
4
.
1
1
T.
O
.
P
.
=
4
9
3
9
.
5
4
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
3
+
3
5
.
3
6
T.
O
.
P
.
=
4
9
3
8
.
5
6
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
3
+
5
0
.
5
1
T.
O
.
P
.
=
4
9
3
8
.
5
0
TE
E
-
8
"
X
4
"
ST
A
.
=
1
3
+
8
2
.
8
2
T.
O
.
P
.
=
4
9
3
8
.
3
7
TE
E
-
8
"
X
4
"
ST
A
.
=
1
5
+
5
0
.
3
1
T.
O
.
P
.
=
4
9
3
8
.
6
8
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
5
+
8
4
.
9
1
T.
O
.
P
.
=
4
9
3
8
.
9
2
SE
R
V
I
C
E
T
A
P
-
2
"
Ø
ST
A
.
=
1
5
+
9
5
.
7
5
T.
O
.
P
.
=
4
9
3
8
.
8
6
TE
E
-
8
"
X
4
"
ST
A
.
=
1
6
+
5
3
.
8
0
T.
O
.
P
.
=
4
9
3
8
.
5
7
SE
R
V
I
C
E
T
A
P
-
1
.
5
"
Ø
ST
A
.
=
1
6
+
6
3
.
1
4
T.
O
.
P
.
=
4
9
3
8
.
5
3
BE
N
D
-
9
0
°
ST
A
.
=
1
6
+
9
8
.
9
2
T.
O
.
P
.
=
4
9
3
8
.
3
5
BE
N
D
-
9
0
°
ST
A
.
=
1
8
+
6
5
.
9
9
T.
O
.
P
.
=
4
9
3
7
.
5
1
SW
I
V
E
L
T
E
E
-
8
"
X
6
"
ST
A
.
=
1
8
+
7
7
.
8
1
T.
O
.
P
.
=
4
9
3
7
.
4
5
TE
E
-
8
"
X
8
"
ST
A
.
=
2
0
+
2
4
.
9
9
T.
O
.
P
.
=
4
9
3
7
.
9
2
±18"
±19"±18"
40' MJR
5' MJR
10' MJR
40' MJR 40' MJR
40' MJR 40' MJR
40' MJR 40' MJR
1' MJR
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
3
P
L
A
N
&
P
R
O
F
I
L
E
49
1" = 40'
N/A
C 624
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
WATER LINE 3
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
HYD
T
E
S
T
S
T
A
H
2
O
V
A
U
L
T
E
L
E
C
ST
HY
D
E
L
E
C
S
F.
O
.
W
X
X
XX
SS
X
X
X
X
X
X
12" W
12" W
12
"
W
E
12
Ŕ
W
E
8"
W
W G E
E
G
G
G
12
"
W
12
"
W
E
FO
12
"
W
24
"
W
24
"
W
24" W
ST
STST
ST
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
12" W 12" W 12" W
12" W
12" W
12" W
12" W
12" W12" W12" W12" W
12" W
12" W
12" W
12" W
G
G G G G G G G G G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
E
E
UD
E
E
E
E
E
E
E
E
E
E
EEEEEEEEEEE
E E E E E E E E E E E
E
E
E
E
E
E
E
E
E
E
VAULT
ELEC
VAULT
ELEC
E
E
E
UD
UD
UD
E
E
E
10+00 11+00 12+00 13+00
14+00
15+00
16+00
17+00
18+00
STA.=17+96.53 | OFF.=0.0' R
N=133006.52
E=201901.65
REDUCER-12"x6"
6" GV (SW)
STA.=18+02.53 | OFF.=0.0'
N=133011.22
E=201905.38
TEMP. HYDRANT
6" GV (SE)
STA.=10+00.00 | OFF.=0.0'
N=132347.50
E=201457.58
SWIVEL TEE-12"x6"
CONNECT TO EX. 12" PVC
8" GV (NW)
12" GV (SW)
12" GV (NE)
STA.=17+47.65 | OFF.=0.0'
N=132968.25
E=201871.25
CROSS-12"x8"
6" GV (NW)
STA.=13+66.71 | OFF.=0.0'
N=132664.59
E=201641.47
SWIVEL TEE-12"x6"
N28°40'33"E
155.22 LF 12" PVC
211.48 LF 12"P V C
R=2 490.00'
N38°27'54"
E
169.46 LF
1
2
"
P
V
C
N38°27'55"
E
54.88 LF 1
2
"
P
V
C
STORM DRAIN 3
SEE SHEET C 631
STORM DRAIN 3-2
SEE SHEET C 632
STORM DRAIN 3-3
SEE SHEET C 632
STORM DRAIN 2
SEE SHEET C 630
POND OUTFALL 1-1
SEE SHEET C 630
STORM DRAIN 4
SEE SHEET C 630
WATER LINE 1
SEE SHEETS C 620 - C 621
SANITARY SEWER B
SEE SHEETS C 613 - C 614
SANITARY SEWER A
SEE SHEET C 612
SANITARY SEWER B1
SEE SHEET C 614
DETENTION
POND 1
CORDOVA R
O
A
D
15' UTILITY
EASEMENT
15' UTILITY
EASEMENT
RAIN GARDEN C
42' HALF ROW
52' FL-FL
STA.=13+66.71 | OFF.=39.0' L
N=132686.17
E=201608.99
FIRE HYDRANT
DETENTION
POND 2
STORM DRAIN 6
SEE SHEET C 634
EXISTING FIRE HYDRANT
TO BE RECONNECTED
NO
R
T
H
L
I
N
K
L
A
N
E
DU
F
F
D
R
I
V
E
HALF ROW VARIES
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
12" PVC
12" PVC 12" PVC
12" PVC
ST
A
.
=
1
1
+
5
5
.
2
2
T.
O
.
P
.
=
4
9
3
6
.
7
1
0°
B
E
N
D
0.
4
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
3
+
6
6
.
7
1
T.
O
.
P
.
=
4
9
3
6
.
8
9
0°
B
E
N
D
0.
1
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
5
+
7
8
.
1
9
T.
O
.
P
.
=
4
9
3
6
.
5
6
0°
B
E
N
D
0.
2
°
D
E
F
L
E
C
T
I
O
N
ST
A
.
=
1
7
+
4
7
.
6
5
T.
O
.
P
.
=
4
9
3
6
.
8
7
1°
B
E
N
D
0.
9
°
D
E
F
L
E
C
T
I
O
N
TO
P
=
4
9
3
7
.
7
3
TO
P
=
4
9
3
7
.
4
0
TO
P
=
4
9
3
7
.
0
7
TO
P
=
4
9
3
6
.
7
4
TO
P
=
4
9
3
6
.
7
5
TO
P
=
4
9
3
6
.
7
9
TO
P
=
4
9
3
6
.
8
3
TO
P
=
4
9
3
6
.
8
8
TO
P
=
4
9
3
6
.
8
4
TO
P
=
4
9
3
6
.
7
6
TO
P
=
4
9
3
6
.
6
8
TO
P
=
4
9
3
6
.
6
0
TO
P
=
4
9
3
6
.
6
0
TO
P
=
4
9
3
6
.
6
9
TO
P
=
4
9
3
6
.
7
8
TO
P
=
4
9
3
6
.
9
1
TO
P
=
4
9
3
7
.
7
8
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50
SW
I
V
E
L
T
E
E
-
1
2
"
X
6
"
ST
A
.
=
1
3
+
6
6
.
7
1
T.
O
.
P
.
=
4
9
3
6
.
8
9
CR
O
S
S
-
1
2
"
X
8
"
ST
A
.
=
1
7
+
4
7
.
6
5
T.
O
.
P
.
=
4
9
3
6
.
8
7
RE
D
U
C
E
R
-
1
2
"
X
6
"
ST
A
.
=
1
7
+
9
6
.
5
3
T.
O
.
P
.
=
4
9
3
7
.
7
2
TE
M
P
.
H
Y
D
R
A
N
T
ST
A
.
=
1
8
+
0
2
.
5
3
T.
O
.
P
.
=
4
9
3
7
.
8
3
SW
I
V
E
L
T
E
E
-
1
2
"
X
6
"
CO
N
N
E
C
T
T
O
E
X
.
1
2
"
P
V
C
ST
A
.
=
1
0
+
0
0
.
0
0
T.
O
.
P
.
=
4
9
3
7
.
7
3
15" RCP STORM
STA.=10+11.26
B.O.P.=4939.43 15" RCP STORM
STA.=13+16.08
B.O.P.=4938.63
15" RCP STORM
STA.=16+54.25
B.O.P.=4938.33
10" PVC SANITARY
STA.=17+58.02
T.O.P.=4934.47
±18"
±20"±18"
±21"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
WA
T
E
R
L
I
N
E
4
P
L
A
N
&
P
R
O
F
I
L
E
50
1" = 40'
N/A
C 625
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT, LATEST EDITION.
3.ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT
SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A 4.5' - 5.5' FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT
LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY
PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE
DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING
INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS
STREET REPAIR STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO
14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED
TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.THE ABBREVIATION "E&BE" SHALL STAND FOR "EAST LARIMER COUNTY WATER
DISTRICT AND BOXELDER SANITATION DISTRICT EASEMENTS" IN THESE PLANS.
12.THE ABBREVIATION "EAE" SHALL STAND FOR "EMERGENCY ACCESS EASEMENT" IN
THESE PLANS.
13.THE ABBREVIATION "PAE" SHALL STAND FOR "PUBLIC ACCESS EASEMENT" IN
THESE PLANS.
14.FORT COLLINS HAS ACTIVE IRRIGATION IN THE PUBLIC RIGHT-OF-WAY ALONG N
LEMAY AVE. ANY IRRIGATION LINES, INFRASTRUCTURE, OR RELATED EQUIPMENT
THAT IS DISTURBED, DAMAGED, DESTROYED, OR MOVED, SHALL BE PROMPTLY
REPLACED AND/OR REPAIRED AT NO COST TO THE CITY. IRRIGATION PLANS FOR
THIS AREA ARE AVAILABLE UPON REQUEST.
15.ANY LANDSCAPING THAT IS DAMAGED OR DESTROYED IN THE PUBLIC
RIGHT-OF-WAY ALONG N LEMAY AVENUE SHALL BE PROMPTLY REPLACED AND/OR
REPAIRED AT NO COST TO THE CITY.
16.ALL WATER SERVICE LINES DESIGNATED FOR UP-SIZING SHALL BE UP-SIZED 5'
FROM THE WATER METER IN THE DIRECTION OF THE BUILDING BEING SERVED.
17.ALL FIRE HYDRANT ASSEMBLIES INSTALLED OR RE-FITTED FOR THESE PLANS ARE
TO INCLUDE THRUST BLOCKS PER ELCO STANDARD DETAIL DRAWING 018 (SEE
SHEET C 802)
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
EXISTING TELEPHONE PEDESTAL
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
LEGEND
NOTES
WATER LINE 4
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
T
E
S
T
S
T
A
H
2
O
V
A
U
L
T
E
L
E
C
ST
12" W
12
"
W
E
12
Ŕ
W
E
24
"
W
24
"
W
24
"
W
ST
/
/
/
/
/
/
/
/
G
G
G
G
E
E
EE
10+00
EX INLET 1
STA.=10+20.00
N=132348.65
E=201383.54
25.22 LF 15" RCP @ 0.85%
OUTLET 1-1
STA.=10+45.22
N=132373.87
E=201382.93
25.19 LF 15" RCP @ 0.85%
STA.=10+70.41
N=132399.05
E=201382.32
OUTLET 1-2
DU
F
F
D
R
I
V
E
CORDOVA ROAD
DETENTION
POND 2
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
1
.
8
1
9+509+50 10+00 10+50 11+00 11+25
EX
I
N
L
E
T
1
ST
A
1
0
+
2
0
.
0
0
FL
.
E
L
.
=
4
9
3
5
.
9
±
IN
V
.
I
N
4
9
3
4
.
4
8
(
N
)
IN
V
.
O
U
T
4
9
3
4
.
4
8
(
S
W
)
25.22 LF 15" RCP @ 0.85%
OU
T
L
E
T
1
-
1
ST
A
1
0
+
4
5
.
2
2
FL
.
E
L
.
=
4
9
4
3
.
8
±
IN
V
.
I
N
4
9
3
4
.
7
0
(
N
)
IN
V
.
O
U
T
4
9
3
4
.
7
0
(
S
)
25.19 LF 15" RCP @ 0.85%
OU
T
L
E
T
1
-
2
ST
A
1
0
+
7
0
.
4
1
FL
.
E
L
.
=
4
9
3
7
.
4
±
IN
V
.
O
U
T
4
9
3
4
.
9
1
(
S
)
100-YR HGL
HYD
TEST
STAH2O
VAUL
T
ELEC
12
"
W
E
G
/ / / / / / / /
12
"
W
12
"
W
12
"
W
G G
G
G
G
G G
E E
E
E
E
E
E
E
E
E
11+00
STA.=10+53.87
N=132374.76
E=201431.29
INLET 2-1
STA.=11+05.87
N=132349.76
E=201476.88
INLET 2-2
FES 2
STA.=10+00.00
N=132413.66
E=201394.03
53.87 LF 15" RCP @ 8.15%
52.00 LF 15" RCP @ 0.50%
CO
R
D
O
V
A
R
O
A
D
CO
R
D
O
V
A
R
O
A
D
WATER LINE 4
SEE SHEET C 625
DETENTION
POND 2
HYD
X
X
XX
X
X
X12
"
W
12
"
W
12
"
W
G
G
G
G
U
D
E
E
E
E E
E
E
E
VA
U
L
T
EL
E
C
11+00 STA.=11+00.88
N=132885.17
E=201825.68
INLET 4-2
STA.=10+48.88
N=132917.52
E=201784.96
INLET 4-1
FES 4
STA.=9+99.83
N=132916.71
E=201735.86
49.11 LF 15" RCP @ 0.50%
52.00 LF 15" RCP @ 0.50%
CO
R
D
O
V
A
R
O
A
D
STORM DRAIN 6
SEE SHEET C 634
STORM DRAIN 8
SEE SHEET C 634
WATER LINE 4
SEE SHEET C 625
DETENTION
POND 1
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
3
5
.
0
5
FG
=
4
9
4
3
.
7
0
FG
=
4
9
4
3
.
0
0
9+509+50 10+00 10+50 11+00 11+50
53.87 LF 15" RCP @ 8.15%
52.00 LF 15" RCP @ 0.50%
IN
L
E
T
2
-
1
ST
A
1
0
+
5
3
.
8
7
FL
.
E
L
.
=
4
9
4
3
.
1
±
IN
V
.
I
N
4
9
3
9
.
4
4
(
S
E
)
IN
V
.
O
U
T
4
9
3
9
.
4
4
(
N
W
)
IN
L
E
T
2
-
2
ST
A
1
1
+
0
5
.
8
7
FL
.
E
L
.
=
4
9
4
2
.
7
±
IN
V
.
O
U
T
4
9
3
9
.
7
0
(
N
W
)
FE
S
2
ST
A
1
0
+
0
0
.
0
0
IN
V
.
I
N
4
9
3
5
.
0
5
(
S
E
)
100-YR HGL
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
3
8
.
0
9
FG
=
4
9
4
1
.
6
6
FG
=
4
9
4
1
.
6
4
9+509+50 10+00 10+50 11+00 11+50
49.11 LF 15" RCP @ 0.50%
52.00 LF 15" RCP @ 0.50%
IN
L
E
T
4
-
2
ST
A
1
1
+
0
0
.
8
8
FL
.
E
L
.
=
4
9
4
1
.
6
±
IN
V
.
O
U
T
4
9
3
8
.
6
0
(
N
W
)
IN
L
E
T
4
-
1
ST
A
1
0
+
4
8
.
8
8
FL
.
E
L
.
=
4
9
4
1
.
6
±
IN
V
.
I
N
4
9
3
8
.
3
4
(
S
E
)
IN
V
.
O
U
T
4
9
3
8
.
3
4
(
W
)
FE
S
4
ST
A
9
+
9
9
.
8
3
IN
V
.
I
N
4
9
3
8
.
0
9
(
E
)
100-YR HGL
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
3
.
0
0
9+509+50 10+00 10+50 11+00
27.58 LF
15" HDPE
@ 0.50%
FE
S
7
-
1
ST
A
1
0
+
0
0
.
0
0
IN
V
.
I
N
4
9
4
3
.
0
0
(
N
E
)
FE
S
7
-
2
ST
A
1
0
+
2
7
.
5
8
IN
V
.
O
U
T
4
9
4
3
.
1
4
(
S
W
)
±12"
±16" (TYP.)
4" PVC UNDERDRAIN
(PERFORATED)
4" PVC UNDERDRAIN
(NON-PERFORATED)
V
A
U
L
T
ELEC
E
E
E
E
E
S
W
ST
EEE
F
UD
UD
UD
UD
FES 7-1
STA.=10+00.00
N=133170.71
E=200904.61
27.58 LF 15" HDPE @ 0.50%
STA.=10+27.58
N=133193.27
E=200920.48
FES 7-2
CARRIAGE
HOUSE 5
CARRIAGE
HOUSE 6
NORTH LEMA
Y
A
V
E
N
U
E
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
S
1
,
2
,
4
,
&
7
P
L
A
N
&
P
R
O
F
I
L
E
51
1" = 40'
1" = 5'
C 630
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
7
4
1 2
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
7.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
8.ALL UNDERDRAIN RUNS TO BE INSTALLED BELOW AND PARALLEL TO OTHER PIPING
SHALL USE NON-PERFORATED PIPE. IN ALL OTHER INSTANCES UNDERDRAIN PIPING
SHALL BE PERFORATED UNLESS SPECIFIED OTHERWISE.
9.REFER TO SHEET C 806 FOR INLET SCHEDULE.
PROPOSED RIGHT OF WAY
NOTES
LEGEND
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
STORM DRAIN 7
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 4
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 1
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
G
G
G G G G
F
T
T
T
G
G
G
G
G
G
G
G
G
G
G
S
S
W
S
S
F
W
E
E
E
E
E
S
S
S
S
W
F
F
W
E
E E E E E E
S
W
T
UD
UD
W
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
E
E
E
EE
E
E E E
E
E
E
E
T
E
E
EE
E E E E E E
T
E
S
S
W
W
W
T
E E EE
E
E
E
E
E
E
E
E
T
E
E
E
E
E
E
E
E
E
E
E
E
E
UD
U
D
U
D UD
F
F
F
F
E
E E
EEE
EEE
E
E
E
E
E
E
E
E
E
UD
11
+
0
0
12
+
0
0
13+00 14+00 15+00
16+00
17+00
18+00
19+00
BASIN 3-11
STA.=19+03.49
N=133128.12
E=200992.47
BASIN 3-10.1
INV. OUT=4943.54 (NE)
FG=4946.32
BASIN 3-9.1
INV. OUT=4943.50 (NE)
FG=4946.11
BASIN 3-10
STA.=18+86.58
N=133117.60
E=201005.70
BASIN 3-8.1
INV. OUT=4942.72 (NE)
FG=4945.82
BASIN 3-9
STA.=18+53.83
N=133097.23
E=201031.34
BASIN 3-7.1
INV. OUT=4942.35 (NE)
FG=4945.55
BASIN 3-6.1
INV. OUT=4941.66 (NE)
FG=4945.20
BASIN 3-7
STA.=17+27.72
N=133018.76
E=201130.06
BASIN 3-6
STA.=16+81.24
N=132989.84
E=201166.45
STA.=15+21.63
N=132889.79
E=201290.82
INLET 3-5
BASIN 3-8
STA.=17+93.39
N=133059.61
E=201078.66
STMH 3-3
STA.=12+00.71
N=132715.59
E=201560.34
STMH 3-2
STA.=11+50.55
N=132673.62
E=201532.88
STA.=12+88.48
N=132766.17
E=201488.53
INLET 3-4
STA.=10+42.67
N=132583.05
E=201474.28
INLET 3-1
STA.=10+00.00
N=132540.80
E=201468.25
FES 3
42.67 LF 30" RCP @ 0.50%
10
7
.
8
8
L
F
2
4
"
H
D
P
E
@
0
.
5
0
%
50.16 LF 24" HDPE @ 0.50%
87.84 LF 24" HDPE @ 0.50%
233.17 LF 24" HDPE @ 0.50%
159.62 LF 12" HDPE @
1
.
5
0
%
46.48 LF 12" HDPE @ 1.50%
65.66 LF 12" HDPE @ 1.50%
60.45 LF
12" HDPE
@ 1.50%
32.75 LF
12" HDPE
@ 1.50%
16.90 LF
12" HDPE
@ 1.50%
15.00 LF
8" HDPE
@ 5.00%
15.01 LF
8" HDPE
@ 5.00%15.02 LF
8" HDPE
@ 0.84%
15.04 LF 8" HDPE @ 0.02%
15.04 LF
8" HDPE
@ 3.00%
38.26 LF 8" HDPE @ 0.35%
42.75 LF 8" HDPE @ 0.35%
AD 3-5.1 OUTFALL
INV. IN=4942.75 (SW)
FG=4942.85
AD 3-5.1 BASIN 1
INV. IN=4942.88 (SW)
INV. OUT=4942.88 (NE)
FG=4944.41
AD 3-5.1 BASIN 2
INV. OUT=4943.03 (NE)
FG=4944.25
22.36 LF 8" HDPE @ 0.40%
34.57 LF 8" HDPE @ 0.40%
28.35 LF 8" HDPE @ 0.40%
53.46 LF 8" HDPE @ 0.40%
28.47 LF 8" HDPE @ 0.40%
AD 3-5.2 OUTFALL
INV. IN=4942.75 (NE)
FG=4942.78
AD 3-5.2 BASIN 1
INV. IN=4942.84 (NE)
INV. OUT=4942.84 (SW)
FG=4944.45
AD 3-5.2 BASIN 5
INV. OUT=4943.42 (SW)
FG=4944.76
AD 3-5.2 BASIN 3
INV. IN=4943.09 (NE)
INV. OUT=4943.09 (SW)
FG=4944.77
AD 3-5.2 BASIN 4
INV. IN=4943.31 (NE)
INV. OUT=4943.31 (SW)
FG=4944.77
AD 3-5.2 BASIN 2
INV. IN=4942.98 (NE)
INV. OUT=4942.98 (SW)
FG=4944.77
4925
4930
4935
4940
4945
4950
4955
4960
4965
4925
4930
4935
4940
4945
4950
4955
4960
4965
FG
=
4
9
3
5
.
7
1
FG
=
4
9
4
0
.
4
2
FG
=
4
9
4
1
.
5
1
FG
=
4
9
4
2
.
7
6
FG
=
4
9
4
3
.
1
8
FG
=
4
9
4
3
.
1
9
FG
=
4
9
4
2
.
6
0
FG
=
4
9
4
2
.
6
0
FG
=
4
9
4
2
.
8
9
FG
=
4
9
4
2
.
7
9
FG
=
4
9
4
3
.
7
4
FG
=
4
9
4
2
.
7
5
FG
=
4
9
4
3
.
4
7
FG
=
4
9
4
5
.
1
9
FG
=
4
9
4
5
.
9
2
FG
=
4
9
4
6
.
0
2
FG
=
4
9
4
6
.
1
7
FG
=
4
9
4
6
.
3
0
FG
=
4
9
4
6
.
9
6
9+509+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50
BA
S
I
N
3
-
1
1
ST
A
1
9
+
0
3
.
4
9
FL
.
E
L
.
=
4
9
4
6
.
6
±
IN
V
.
O
U
T
4
9
4
4
.
0
7
(
S
E
)
BA
S
I
N
3
-
1
0
ST
A
1
8
+
8
6
.
5
8
FL
.
E
L
.
=
4
9
4
5
.
0
±
IN
V
.
I
N
4
9
4
3
.
9
9
(
S
W
)
IN
V
.
I
N
4
9
4
3
.
8
2
(
N
W
)
IN
V
.
O
U
T
4
9
4
3
.
8
2
(
S
E
)
BA
S
I
N
3
-
8
ST
A
1
7
+
9
3
.
3
9
FL
.
E
L
.
=
4
9
4
5
.
9
±
IN
V
.
I
N
4
9
4
2
.
4
2
(
N
W
)
IN
V
.
I
N
4
9
4
2
.
5
9
(
S
W
)
IN
V
.
O
U
T
4
9
4
2
.
4
2
(
S
E
)
BA
S
I
N
3
-
7
ST
A
1
7
+
2
7
.
7
2
FL
.
E
L
.
=
4
9
4
5
.
2
±
IN
V
.
I
N
4
9
4
1
.
6
0
(
S
W
)
IN
V
.
I
N
4
9
4
1
.
4
4
(
N
W
)
IN
V
.
O
U
T
4
9
4
1
.
4
4
(
S
E
)
IN
L
E
T
3
-
5
ST
A
1
5
+
2
1
.
6
3
FL
.
E
L
.
=
4
9
4
3
.
8
±
IN
V
.
I
N
4
9
3
8
.
3
5
(
N
W
)
IN
V
.
O
U
T
4
9
3
8
.
3
1
(
S
E
)
IN
L
E
T
3
-
4
ST
A
1
2
+
8
8
.
4
8
FL
.
E
L
.
=
4
9
4
2
.
2
±
IN
V
.
I
N
4
9
3
7
.
1
4
(
N
W
)
IN
V
.
O
U
T
4
9
3
7
.
1
5
(
S
E
)
IN
L
E
T
3
-
1
ST
A
1
0
+
4
2
.
6
7
FL
.
E
L
.
=
4
9
4
0
.
9
±
IN
V
.
I
N
4
9
3
5
.
9
2
(
N
E
)
IN
V
.
O
U
T
4
9
3
5
.
9
2
(
S
)
BA
S
I
N
3
-
6
ST
A
1
6
+
8
1
.
2
4
FL
.
E
L
.
=
4
9
4
5
.
2
±
IN
V
.
I
N
4
9
4
0
.
7
4
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
9
1
(
S
W
)
IN
V
.
O
U
T
4
9
4
0
.
7
4
(
S
E
)
ST
M
H
3
-
2
ST
A
1
1
+
5
0
.
5
5
RI
M
4
9
4
2
.
8
±
IN
V
.
I
N
4
9
3
6
.
4
6
(
N
E
)
IN
V
.
I
N
4
9
3
6
.
4
6
(
S
E
)
IN
V
.
O
U
T
4
9
3
6
.
4
6
(
S
W
)
ST
M
H
3
-
3
ST
A
1
2
+
0
0
.
7
1
RI
M
4
9
4
3
.
2
±
IN
V
.
I
N
4
9
3
6
.
7
1
(
N
W
)
IN
V
.
I
N
4
9
3
6
.
7
1
(
N
E
)
IN
V
.
O
U
T
4
9
3
6
.
7
1
(
S
W
)
8" PVC WATER
STA.=14+78.44
T.O.P.=4936.308" PVC SANITARY
STA.=10+76.69
T.O.P.=4935.31
±18"
BA
S
I
N
3
-
9
ST
A
1
8
+
5
3
.
8
3
FL
.
E
L
.
=
4
9
4
6
.
2
±
IN
V
.
I
N
4
9
4
3
.
5
0
(
S
W
)
IN
V
.
I
N
4
9
4
3
.
3
3
(
N
W
)
IN
V
.
O
U
T
4
9
4
3
.
3
3
(
S
E
)
FE
S
3
ST
A
1
0
+
0
0
.
0
0
IN
V
.
I
N
4
9
3
5
.
7
1
(
N
)
42.67 LF
30" RCP
@ 0.50%
107.88 LF 24" HDPE @ 0.50%
50.16 LF 24" HDPE @ 0.50%
87.84 LF 24" HDPE @ 0.50%
233.17 LF 24" HDPE @ 0.50%
159.62 LF 12" H
D
P
E
@
1
.
5
0
%
46.48 LF 12" HDPE @ 1.50%
65.66 LF 12" HDPE @ 1.50%
60.45 LF 12" HDPE @ 1.50%
32.75 LF 12" HDPE @ 1.50%
16.90 LF
12" HDPE
@ 1.50%
±5" CLEARANCE
INSTALL FLOWFILL
AT CROSSING
100-YR HGL
±26"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
3
P
L
A
N
&
P
R
O
F
I
L
E
52
1" = 40'
1" = 5'
C 631
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
7.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
8.ALL UNDERDRAIN RUNS TO BE INSTALLED BELOW AND PARALLEL TO OTHER PIPING
SHALL USE NON-PERFORATED PIPE. IN ALL OTHER INSTANCES UNDERDRAIN PIPING
SHALL BE PERFORATED UNLESS SPECIFIED OTHERWISE.
9.REFER TO SHEET C 806 FOR INLET SCHEDULE.
PROPOSED RIGHT OF WAY
NOTES
LEGEND
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
STORM DRAIN 3
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
12
"
W
12
"
W
12
"
W
12
"
W
12
"
W
G
G
G
G
G
E
E E
E
E
E
E
EE
E
E
E
E
11+00
INLET 3-2.2
STA.=11+11.98
N=132613.56
E=201627.39
INLET 3-2.1
STA.=10+59.98
N=132641.45
E=201583.50
59.98 LF 15" RCP @ 3.63%
52.00 LF 15" RCP @ 0.50%
STA.=10+00.00
N=132673.62
E=201532.88
STMH 3-2
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
2
.
7
6
FG
=
4
9
4
2
.
6
1
FG
=
4
9
4
2
.
3
9
9+509+5010+0010+5011+0011+50
59.98
L
F
1
5
"
R
C
P
@
3
.
6
3
%
IN
L
E
T
3
-
2
.
1
ST
A
1
0
+
5
9
.
9
8
FL
.
E
L
.
=
4
9
4
1
.
9
±
IN
V
.
I
N
4
9
3
8
.
6
4
(
S
E
)
IN
V
.
O
U
T
4
9
3
8
.
6
4
(
N
W
)
52.00 LF 15" RCP @ 0.50%
IN
L
E
T
3
-
2
.
2
ST
A
1
1
+
1
1
.
9
8
FL
.
E
L
.
=
4
9
4
1
.
9
±
IN
V
.
O
U
T
4
9
3
8
.
9
0
(
N
W
)
ST
M
H
3
-
2
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
2
.
8
±
IN
V
.
I
N
4
9
3
6
.
4
6
(
N
E
)
IN
V
.
I
N
4
9
3
6
.
4
6
(
S
E
)
IN
V
.
O
U
T
4
9
3
6
.
4
6
(
S
W
)
12" PVC WATER
STA.=10+95.98
T.O.P.=4936.85
100-YR HGL
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
3
.
2
1
FG
=
4
9
4
0
.
1
7
9+509+50 10+00 10+50 11+00
58.27 LF 18" RCP @ 0.63%
OU
T
L
E
T
3
-
3
.
1
ST
A
1
0
+
5
8
.
2
7
FL
.
E
L
.
=
4
9
3
9
.
0
±
IN
V
.
O
U
T
4
9
3
7
.
0
8
(
S
W
)
ST
M
H
3
-
3
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
3
.
2
±
IN
V
.
I
N
4
9
3
6
.
7
1
(
N
W
)
IN
V
.
I
N
4
9
3
6
.
7
1
(
N
E
)
IN
V
.
O
U
T
4
9
3
6
.
7
1
(
S
W
)
100-YR HGL
12" W
12" W
12" W
12" W
12" W
G G
G
G
G
E
E
E
E
E
EE
E E
E
STA.=10+58.27
N=132754.04
E=201604.13
OUTLET 3-3.1
58.27 LF 18" RCP @ 0.63%
STA.=10+00.00
N=132715.59
E=201560.34
STMH 3-3
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
4
5
.
6
9
FG
=
4
9
4
3
.
5
0
9+509+5010+0010+5011+00
ST
M
H
5
-
2
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
5
.
7
±
IN
V
.
I
N
4
9
3
7
.
8
2
(
S
E
)
IN
V
.
I
N
4
9
3
9
.
1
5
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
7
9
(
S
W
)
31.85 LF 24" HDPE @ 2.00%
IN
L
E
T
5
-
2
.
1
ST
A
1
0
+
3
1
.
8
5
FL
.
E
L
.
=
4
9
4
4
.
5
±
IN
V
.
O
U
T
4
9
4
1
.
4
3
(
N
E
)
G G G G
G
G
G
G
G
TF
E
E
E
E
E
E
T
S
VA
U
L
T
EL
E
C
VA
U
L
T
EL
E
C
E
E
EE
UD
UD
UD
E E
E
10+00
INLET 5-2.1
STA.=10+31.85
N=132684.05
E=200965.52
STA.=10+00.00
N=132711.87
E=200981.02
STMH 5-2
31.85 LF 24" HDPE @ 2.00%
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
3
-
2
,
3
-
3
,
&
5
-
2
P
L
A
N
&
P
R
O
F
I
L
E
53
1" = 40'
1" = 5'
C 632
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
7.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
8.ALL UNDERDRAIN RUNS TO BE INSTALLED BELOW AND PARALLEL TO OTHER PIPING
SHALL USE NON-PERFORATED PIPE. IN ALL OTHER INSTANCES UNDERDRAIN PIPING
SHALL BE PERFORATED UNLESS SPECIFIED OTHERWISE.
9.REFER TO SHEET C 806 FOR INLET SCHEDULE.
PROPOSED RIGHT OF WAY
NOTES
LEGEND
3-3
3-25-2
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
STORM DRAIN 5-2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 3-3
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 3-2
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
V.P.
VAU
L
T
ELEC
VAU
L
T
ELEC
VAUL
T
ELEC
E
E
E
E
E
E
E
E
E
WF
E
E
E
E
F
E
E
E
S
F
W
S
W
E
S
S
S
S
W
S
W
E
E
E
E
E
W
W
S
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
W
U
D
UD
U
D
F
F
F
U
D
UD
UD
UD
UD
UD
UD
UD
UD
11+00
12+00
13+00
14+00
15+00
16+00
17+0
0
STA.=16+30.79
N=132834.61
E=200760.16
STMH 5-3
STA.=17+04.24
N=132844.15
E=200687.32
STMH 5-4
STA.=13+78.11
N=132711.87
E=200981.02
STMH 5-2
STMH 5-1
STA.=10+84.09
N=132568.59
E=201237.76
STA.=17+50.61
N=132890.29
E=200682.75
CONCRETE FES 5-5
CONCRETE FES 5
STA.=10+00.00
N=132484.51
E=201239.13
8
4
.
0
9
L
F
2
4
"
H
D
P
E
@
0
.
5
0
%
199.95 LF 24" HDP
E
@
0
.
5
0
%
106.43 LF 15" HDP
E
@
0
.
5
0
%
73.45
L
F
1
5
"
H
D
P
E
@
0
.
5
0
%
46.37 LF 15" HDPE @ 0.50%
NO
R
T
H
L
E
M
A
Y
A
V
E
CARRIAGE
HOUSE 2
CARRIAGE
HOUSE 3
CA
R
R
I
A
G
E
HO
U
S
E
4
CARRIAGE
HOUSE 1
BUILDING
5
BUILDING
7
BUILDING
4
FITNESS
CENTER
LEASING
75.39 LF 24" HDP
E
@
0
.
5
0
%
18.48 LF 8" HDPE @ 0.50%
BEND 5-1.2-1
INV. IN=4938.18 (S)
INV. OUT=4938.18 (NE)
FG=4945.76
BASIN 5-1.2-2
INV. OUT=4938.27 (N)
FG=4945.09
14.82 LF 8" HDPE @ 0.50%
STA.=13+02.72
N=132675.13
E=201046.85
TEE 5-1.2
18.67 LF 24" HDPE @ 0.50%
TEE 5-1.1
STA.=12+84.04
N=132666.03
E=201063.16
42.36 LF 8" HDPE @ 0.50%
33.86 LF 8" HDPE @ 0.50%
26.57 LF 8" HDPE @ 0.50%
26.57 LF 8" HDPE @ 0.50%
33.86 LF 8" HDPE
@
0
.
5
0
%
52.75 LF 8" HDPE @ 5.00%
AD 5 BASIN 7
INV. IN=4941.38 (SE)
FG=4944.89
AD 5 BASIN 6
INV. IN=4941.17 (SE)
INV. OUT=4941.17 (NW)
FG=4945.13
AD 5 BASIN 5
INV. IN=4941.00 (SE)
INV. OUT=4941.00 (NW)
FG=4945.24
AD 5 BASIN 4
INV. IN=4940.87 (SE)
INV. OUT=4940.87 (NW)
FG=4944.97
AD 5 BASIN 3
INV. IN=4940.73 (SE)
INV. OUT=4940.73 (NW)
FG=4944.94AD 5 BASIN 2
INV. IN=4940.56 (SE)
INV. OUT=4940.56 (NW)
FG=4944.50
AD 5 BEND 1
INV. IN=4937.93 (E)
INV. OUT=4937.93 (NW)
FG=4944.67
AD 5 OUTFALL
INV. OUT=4935.81 (W)
FG=4935.81
42.42 LF 8" HDPE @ 5.00%
19.78 LF 8" HDPE @ 0.50%
20.92 LF 8" HDPE @ 0.50%
37.29 LF 8" HDPE @ 0.50%
21.35 LF 8" HDPE @ 0.50%
25.12 LF 8" HDPE @ 0.50%
AD 5-2 OUTFALL
INV. IN=4943.51 (W)
FG=4943.51
AD 5-2 BEND 1
INV. IN=4943.64 (NW)
INV. OUT=4943.64 (E)
FG=4946.68
AD 5-2 BASIN 5
INV. IN=4944.14 (NW)
INV. OUT=4944.13 (SE)
FG=4946.03
AD 5-2 BASIN 3
INV. IN=4943.93 (NW)
INV. OUT=4943.93 (SE)
FG=4946.03AD 5-2 BASIN 2
INV. IN=4943.74 (NW)
INV. OUT=4943.74 (SE)
FG=4946.03
AD 5-2 BASIN 4
INV. IN=4944.04 (NW)
INV. OUT=4944.04 (SE)
FG=4946.25
35.07 LF 8" HDPE @ 0.50%
37.29 LF
8" HDPE
@ 0.50%
AD 5-2 BASIN 7
INV. IN=4944.50 (NE)
INV. OUT=4944.50 (SE)
FG=4945.95
AD 5-2 BASIN 6
INV. IN=4944.32 (NW)
INV. OUT=4944.32 (SE)
FG=4946.03
46.92 LF 8" HDPE @ 0.50%
AD 5-2 BASIN 8
INV. OUT=4944.73 (SW)
FG=4945.91
76.01 LF 8" HDPE @ 0.50%
47.31 LF 8" HDPE @ 0.50%
53.19 LF 8" HDPE @ 0.50%
BASIN 5-1.1-1
INV. IN=4938.39 (NE)
INV. OUT=4938.39 (SW)
FG=4943.38
BASIN 5-1.1-2
INV. IN=4938.63 (NE)
INV. OUT=4938.63 (SW)
FG=4944.25
BASIN 5-1.1-3
INV. OUT=4938.90 (SW)
FG=4944.25
146.25 LF 15" HDP
E
@
0
.
5
0
%
STA.=14+84.53
N=132763.57
E=200888.00
TEE 5-2.1
81.44 LF 8" HDPE
@
0
.
5
0
%
32.20 LF 8" HDPE @ 0.50%
28.65 LF 8" HDPE @ 0.50%
BASIN 5-2.1-1.1
INV. OUT=4940.80 (NW)
FG=???
BASIN 5-2.1-3
INV. OUT=4940.70 (SW)
FG=???
BASIN 5-2.1-2
INV. IN=4940.54 (NE)
INV. OUT=4940.54 (S)
FG=???
BASIN 5-2.1-1
INV. IN=4940.40 (N)
INV. IN=4940.40 (SE)
INV. OUT=4940.40 (SW)
FG=???
8
5
.
6
6
L
F
8
"
H
D
P
E
@
0
.
5
0
%
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
FG
=
4
9
3
5
.
7
1
FG
=
4
9
4
5
.
5
4
FG
=
4
9
4
4
.
7
0
FG
=
4
9
4
4
.
8
5
FG
=
4
9
4
5
.
0
3
FG
=
4
9
4
5
.
1
4
FG
=
4
9
4
5
.
2
8
FG
=
4
9
4
5
.
8
4
FG
=
4
9
4
5
.
2
8
FG
=
4
9
4
5
.
5
1
FG
=
4
9
4
5
.
7
4
FG
=
4
9
4
5
.
9
7
FG
=
4
9
4
6
.
2
8
FG
=
4
9
4
6
.
7
3
FG
=
4
9
4
6
.
3
9
FG
=
4
9
4
1
.
3
0
FG
=
4
9
4
1
.
4
6
10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00
84.09 LF 24" HDPE @ 0.50%
199.95 LF 24" HDPE @ 0.50%
106.43 LF 15" HDPE @ 0.50%
73.45 LF 15" HDPE @ 0.50%
46.37 LF
15" HDPE
@ 0.50%
ST
M
H
5
-
3
ST
A
1
6
+
3
0
.
7
9
RI
M
4
9
4
6
.
5
±
IN
V
.
I
N
4
9
4
0
.
4
1
(
W
)
IN
V
.
O
U
T
4
9
4
0
.
4
1
(
S
E
)
ST
M
H
5
-
4
ST
A
1
7
+
0
4
.
2
4
RI
M
4
9
4
6
.
1
±
IN
V
.
I
N
4
9
4
0
.
9
8
(
N
)
IN
V
.
O
U
T
4
9
4
0
.
7
8
(
E
)
ST
M
H
5
-
2
ST
A
1
3
+
7
8
.
1
1
RI
M
4
9
4
5
.
7
±
IN
V
.
I
N
4
9
3
7
.
8
2
(
S
E
)
IN
V
.
I
N
4
9
3
9
.
1
5
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
7
9
(
S
W
)
ST
M
H
5
-
1
ST
A
1
0
+
8
4
.
0
9
RI
M
4
9
4
4
.
5
±
IN
V
.
I
N
4
9
3
6
.
3
5
(
N
W
)
IN
V
.
O
U
T
4
9
3
6
.
3
5
(
S
)
CO
N
C
R
E
T
E
F
E
S
5
-
5
ST
A
1
7
+
5
0
.
6
1
RI
M
4
9
4
2
.
7
±
IN
V
.
O
U
T
4
9
4
1
.
2
1
(
S
)
CO
N
C
R
E
T
E
F
E
S
5
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
3
8
.
2
±
IN
V
.
I
N
4
9
3
5
.
9
3
(
N
)
8" PVC WATER
STA.=13+22.68
T.O.P.=4935.76
6" PVC SANITARY
STA.=11+86.89
B.O.P.=4940.58
100-YR HGL
6" PVC SANITARY
STA.=14+94.91
B.O.P.=4942.67
4" PVC SANITARY
STA.=16+45.56
B.O.P.=4943.50
±18"
±18"
±18"
4" PVC UNDERDRAIN
(PERFORATED)
4" PVC UNDERDRAIN
(NON-PERFORATED)18.67 LF 24" HDPE @ 0.50%
75.39 LF 24" HDPE @ 0.50%
146.25 LF 15" HDPE @ 0.50%
±19"
TE
E
5
-
1
.
1
ST
A
1
2
+
8
4
.
0
4
IN
V
.
I
N
4
9
3
8
.
0
1
(
N
E
)
IN
V
.
O
U
T
4
9
3
7
.
3
5
(
S
E
)
IN
V
.
O
U
T
4
9
3
7
.
3
5
(
N
W
)
TE
E
5
-
1
.
2
ST
A
1
3
+
0
2
.
7
2
IN
V
.
I
N
4
9
3
7
.
4
4
(
S
E
)
IN
V
.
I
N
4
9
3
8
.
1
1
(
S
W
)
IN
V
.
O
U
T
4
9
3
7
.
4
4
(
N
W
)
TE
E
5
-
2
.
1
ST
A
1
4
+
8
4
.
5
3
IN
V
.
I
N
4
9
3
9
.
6
8
(
N
W
)
IN
V
.
I
N
4
9
3
9
.
9
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
9
.
6
8
(
S
E
)
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
5
P
L
A
N
&
P
R
O
F
I
L
E
54
1" = 40'
N/A
C 633
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
50 0 50 100 150 Feet
(IN FEET)
1" = 50 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
7.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
8.ALL UNDERDRAIN RUNS TO BE INSTALLED BELOW AND PARALLEL TO OTHER PIPING
SHALL USE NON-PERFORATED PIPE. IN ALL OTHER INSTANCES UNDERDRAIN PIPING
SHALL BE PERFORATED UNLESS SPECIFIED OTHERWISE.
9.REFER TO SHEET C 806 FOR INLET SCHEDULE.
PROPOSED RIGHT OF WAY
NOTES
LEGEND
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
STORM DRAIN 5
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
1
2
"
W
1
2
"
W
1
2
"
W
E
G
G
G
G
G
G
E
E
E
E
E
E
E
E
E
E
E
E
F
VAULT
ELEC
W
F
W
T
U
D
U
D
UD
E
E
E
E
E
E
VA
U
L
T
EL
E
C
E
VAULT
ELEC
E
E
E
E
E
E
E
E
E
E
E
E
E
11+00
12+00
13+00
14+00
15+00
16+00
STA.=15+02.90
N=133305.46
E=201430.91
STMH 6-7
STA.=14+15.87
N=133237.47
E=201485.24
STMH 6-6 STA.=16+03.96
N=133366.66
E=201350.45
INLET 6-8
STMH 6-1
STA.=10+18.48
N=132989.79
E=201796.00
FES 6
STA.=10+00.00
N=132975.62
E=201784.13
18.48 LF 30" RCP @ 0.30%
205.17 LF 24" HD
P
E
@
0
.
5
0
%
87.03 LF 24" R
C
P
@
0
.
5
0
%
101.09 LF 24"
R
C
P
@
0
.
5
0
%
STA.=12+91.30
N=133159.83
E=201582.66
TEE 6-4
STA.=12+23.65
N=133117.67
E=201635.56
TEE 6-3
67.65 LF 24" HDP
E
@
0
.
5
0
%
67.85 LF 24" HDP
E
@
0
.
5
0
%
STA.=???
N=133202.12
E=201529.59
TEE 6-5
56.72 LF 24" HDPE @ 0.50%
11.81 LF 8" HDPE @ 0.50%
37.55 LF 8" HDPE @ 0.50%
BASIN 6-6.2
INV. OUT=4941.01 (NE)
FG=4942.82
BASIN 6-6.1
INV. IN=4940.82 (SW)
INV. OUT=4940.82 (NE)
FG=4943.37
11.72 LF 8" HDPE @ 2.00%
BASIN 6-5.1
INV. OUT=4940.61 (NE)
FG=4943.37
11.62 LF 8" HDPE @ 2.00%
BASIN 6-4.1
INV. OUT=4940.27 (NE)
FG=4943.37
11.51 LF 8" HDPE @ 2.00%
BASIN 6-3.1
INV. OUT=4939.93 (NE)
FG=4942.87
STORMTECH CHAMBERS
SEE SHEETS C 510 & C 807
DETENTION
POND 1
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
8" PVC SANITARY
STA.=11+35.89
T.O.P.=4935.60
8" PVC SANITARY
STA.=14+70.35
T.O.P.=4937.07
8" PVC WATER
STA.=14+60.10
T.O.P.=4939.038" PVC WATER
STA.=11+45.89
T.O.P.=4937.65
FG
=
4
9
3
8
.
3
8
FG
=
4
9
4
3
.
2
4
FG
=
4
9
4
4
.
0
9
FG
=
4
9
4
2
.
8
5
FG
=
4
9
4
3
.
7
0
FG
=
4
9
4
4
.
0
2
FG
=
4
9
4
4
.
3
5
FG
=
4
9
4
4
.
5
3
FG
=
4
9
4
4
.
8
4
FG
=
4
9
4
4
.
7
7
FG
=
4
9
4
6
.
2
0
FG
=
4
9
4
6
.
0
9
FG
=
4
9
4
5
.
0
7
FG
=
4
9
4
4
.
9
8
9+509+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 16+75
18.48 LF 30" RCP @ 0.30%
205.17 LF 24" HDPE @ 0.50%
87.03 LF 24" RCP @ 0.50%
101.09 LF 24" RCP @ 0.50%
ST
M
H
6
-
7
ST
A
1
5
+
0
2
.
9
0
RI
M
4
9
4
6
.
2
±
IN
V
.
I
N
4
9
4
1
.
3
0
(
N
W
)
IN
V
.
O
U
T
4
9
4
1
.
2
0
(
S
E
)
ST
M
H
6
-
6
ST
A
1
4
+
1
5
.
8
7
RI
M
4
9
4
4
.
7
±
IN
V
.
I
N
4
9
4
0
.
7
6
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
7
6
(
S
W
)
IN
V
.
O
U
T
4
9
4
0
.
6
6
(
S
E
)
IN
L
E
T
6
-
8
ST
A
1
6
+
0
3
.
9
6
RI
M
4
9
4
5
.
0
±
IN
V
.
O
U
T
4
9
4
1
.
8
0
(
S
E
)
ST
M
H
6
-
1
ST
A
1
0
+
1
8
.
4
8
RI
M
4
9
4
2
.
5
±
IN
V
.
I
N
4
9
3
8
.
6
8
(
N
W
)
IN
V
.
O
U
T
4
9
3
8
.
4
4
(
S
W
)
FE
S
6
ST
A
1
0
+
0
0
.
0
0
RI
M
4
9
4
0
.
8
±
IN
V
.
I
N
4
9
3
8
.
3
8
(
N
E
)
±23"
±19"
TE
E
6
-
3
ST
A
1
2
+
2
3
.
6
5
IN
V
.
I
N
4
9
3
9
.
7
0
(
N
W
)
IN
V
.
I
N
4
9
3
9
.
7
0
(
S
W
)
IN
V
.
O
U
T
4
9
3
9
.
7
0
(
S
E
)
67.65 LF 24" HDPE @ 0.50%
TE
E
6
-
4
ST
A
1
2
+
9
1
.
3
0
IN
V
.
I
N
4
9
4
0
.
0
4
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
0
4
(
S
W
)
IN
V
.
O
U
T
4
9
4
0
.
0
4
(
S
E
)
67.85 LF 24" HDPE @ 0.50%
TE
E
6
-
5
ST
A
1
3
+
5
9
.
1
5
IN
V
.
I
N
4
9
4
0
.
3
8
(
N
W
)
IN
V
.
I
N
4
9
4
0
.
3
8
(
S
W
)
IN
V
.
O
U
T
4
9
4
0
.
3
8
(
S
E
)
56.72 LF 24" HDPE @ 0.50%
100-YR HGL
4925
4930
4935
4940
4945
4950
4955
4960
4925
4930
4935
4940
4945
4950
4955
4960
8" PVC SANITARY
STA.=10+95.53
T.O.P.=4935.97
8" PVC WATER
STA.=11+05.96
T.O.P.=4937.43
FG
=
4
9
3
8
.
5
2
FG
=
4
9
4
1
.
8
4
FG
=
4
9
4
2
.
4
7
FG
=
9+509+50 10+00 10+50 11+00 11+50 11+75
IN
L
E
T
8
-
4
ST
A
1
1
+
1
3
.
9
9
RI
M
4
9
4
2
.
8
±
IN
V
.
O
U
T
4
9
3
9
.
0
5
(
E
)
36.18 LF
18" HDPE
@ 0.50%
FE
S
8
ST
A
1
0
+
0
9
.
9
6
IN
V
.
I
N
4
9
3
8
.
7
0
(
N
)
CH
A
M
B
E
R
W
E
I
R
M
H
8
-
2
ST
A
1
0
+
6
3
.
5
6
IN
V
.
I
N
4
9
3
8
.
8
7
(
N
W
)
IN
V
.
I
N
4
9
3
8
.
8
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
8
.
8
7
(
S
)
CH
A
M
B
E
R
M
A
N
I
F
O
L
D
8
-
3
ST
A
1
0
+
7
7
.
8
1
IN
V
.
I
N
4
9
3
8
.
8
7
(
W
)
IN
V
.
I
N
4
9
3
8
.
8
7
(
N
E
)
IN
V
.
O
U
T
4
9
3
8
.
8
7
(
S
E
)
53.59 LF 18" HDPE @ 0.30%±18"
STORMTECH CHAMBERS
SEE SHEETS C 510 & C 807
100-YR HGL
E
G
G
G
G
E
U
D
U
D
E
E
E
E
E
E
E
E
STA.=11+13.99
N=132996.74
E=201629.00
INLET 8-4
STA.=10+77.81
N=132983.31
E=201662.60
CHAMBER MANIFOLD 8-3
CHAMBER WEIR MH 8-2
STA.=10+63.56
N=132974.51
E=201673.81
FES 8
STA.=10+09.96
N=132922.08
E=201684.89
36.18 LF 18" HDPE @ 0.50%
53.59 LF 18" HDPE @ 0.30%
11+00
67.65 LF 24" HDP
E
@
0
.
5
0
%
11.62 LF 8" HDPE @ 2.00%
STORMTECH CHAMBERS
SEE SHEETS C 510 & C 807
DETENTION
POND 1
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
6
&
8
P
L
A
N
&
P
R
O
F
I
L
E
55
1" = 40'
1" = 5'
C 634
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
40 0 40 80 120 Feet
(IN FEET)
1" = 40 ft.
KEYMAP
NOT TO SCALE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
W
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOT LINE
PROJECT BOUNDARY
EXISTING RIGHT OF WAY
EXISTING STORM SEWER
EASEMENT LINE
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES.
3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND
STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF
FLARED END SECTIONS.
4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND
INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF
FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE
R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE
'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443
FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE).
5.CONTRACTOR SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR
THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S
TOLERANCES, ETC.).
6.CONTRACTOR SHALL DEFLECT SERVICE LINES TO AVOID STORM DRAIN LINES.
7.THE DEPTHS OF ALL DRY UTILITY CROSSINGS SHOWN IN PROFILES ARE ASSUMED
BASED ON STANDARD BURY DEPTHS, CONTRACTOR SHALL CONFIRM DRY UTILITY
LOCATIONS IN THE FIELD PRIOR TO REMOVAL/RELOCATION.
8.ALL UNDERDRAIN RUNS TO BE INSTALLED BELOW AND PARALLEL TO OTHER PIPING
SHALL USE NON-PERFORATED PIPE. IN ALL OTHER INSTANCES UNDERDRAIN PIPING
SHALL BE PERFORATED UNLESS SPECIFIED OTHERWISE.
9.REFER TO SHEET C 806 FOR INLET SCHEDULE.
PROPOSED RIGHT OF WAY
NOTES
LEGEND
6
8
STORM DRAIN 8
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
STORM DRAIN 6
PROFILE SCALE:
VERT. 1"=5'
HORIZ. 1"=40'
TEST
STA
TEST
STA
V.P.
ST
F.O.
X
X
XX
X
X
X
X
X
X
X
X
X
FD
C
FD
C
FD
C
FDC
FD
C
FD
C
FDC
FDC
FD
C
FD
C
U
D
UD
UD
UD
UD
UD
UDUD
UD
U
D
UD
UD
U
D
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
UD
/ / / / / / / /
/ / / / / / / /
NO
R
T
H
L
E
M
A
Y
A
V
E
N
U
E
DUFF DRIVE
CO
R
D
O
V
A
R
O
A
D
LINK LANE
A
2.55 ac
B
1.93 ac
D
1.58 ac
C
3.95 ac
E
3.93 ac
F
0.12 ac
G
0.15 ac
H
0.31 ac
I
0.45 ac
J
0.33 ac
K
0.49 ac
OS1
.906 ac
DETENTION
POND 2
RAIN
GARDEN A
RAIN
GARDEN D
RAIN
GARDEN C
DETENTION
POND 1
RAIN
GARDEN B
PROPOSED
STORM DRAIN
PROPOSED
POND OUTFALL
PROPOSED 2'
CONCRETE PAN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED 2'
CONCRETE PAN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
EXISTING
STORM DRAIN
EXISTING
STORM DRAIN
PROPOSED 2'
CONCRETE PAN
C
D
E
B
A
F G
H I
J
K
OS1
POND OUTLET
STRUCTURE
POND OUTLET
STRUCTURE
M
2.47 ac
L
0.64 ac
N
1.01 ac
DOG PARK
PROPOSED
CULVERT
L
MRAIN
GARDEN M
N
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
1.REFER TO THE FINAL DRAINAGE REPORT, DATED NOVEMBER 15, 2023 BY AVANT
CIVIL GROUP FOR ADDITIONAL INFORMATION.
A
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
LEGEND
NOTES
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
DE
V
E
L
O
P
E
D
D
R
A
I
N
A
G
E
E
X
H
I
B
I
T
56
1" = 50'
N/A
C 701
POND SUMMARY TABLE
Pond ID
Tributary
Area
(Ac)1
Weighted %
Imperviousness
(%)
Extended
Detention WQCV
(Cu. Ft.)2
100-Yr.
Detention Vol.
(Ac-Ft)
100-Yr.
Detention
WSEL(Ft)
Peak
Release
(cfs)3
Pond 1 6.291 67
Provided in Pond
2 1.52 4942.40 1.2
Pond 2 12.905 59 6231 2.94 4941.60 2.4
Notes:
1. Tributary area shown does not include off-site basin(s)
2. WQCV calculated minus RG/Chamber volume; will be provded in Pond 2
3. Overall site release rate of 3.6 cfs divided between Ponds 1 and 2
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
SA
N
I
T
A
R
Y
S
E
W
E
R
D
E
T
A
I
L
S
57
N/A
N/A
C 800
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
WA
T
E
R
L
I
N
E
D
E
T
A
I
L
S
58
N/A
N/A
C 801
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
WA
T
E
R
L
I
N
E
D
E
T
A
I
L
S
59
N/A
N/A
C 802
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
D
E
T
A
I
L
S
60
########
N/A
C 803
A A
SECTION A-A
PLAN VIEW (TYP.)
DIRECTION OF FLOW
FLOWLINE OF
DRAIN PIPE
LENGTH
(VARIES, SEE TABLE)
WIDTH
(VARIES,
SEE TABLE)
6.0"
DIRECTION
OF FLOW
6.0" TYP.
SLOPE GRADING TO MATCH RAIN GARDEN
SIDE SLOPE
DRAIN PIPE SIZE VARIES,
SEE TABLE
DRAIN PIPE
RAIN GARDEN SIDE SLOPE
(NATIVE MATERIAL)
RAIN GARDEN
BOTTOM
(BIO-MEDIA)
RIBBED
CONCRETE
RUNDOWN
4.0"12"
RAIN GARDEN
BOTTOM
(BIO-MEDIA)
4.0"
2.0"
6.0"
4.0"
SIDE WALL
HEIGHT
NATIVE MATERIAL
SUB-BASE UNDER
RUNDOWN AND
FOREBAY
RIBBED CONCRETE
RUNDOWN
6.0" THICK
CONCRETE BASE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
D
E
T
A
I
L
S
61
N/A
N/A
C 804
CHK'DMM/DD/YYREV.DESCRIPTION BY
4640 TRUEMAN BLVD
HILLIARD, OHIO 43026
NOTE: ALL DIMENSIONS
ARE ± 1/2 FOOT.
DRAWING NUMBER:
NTS
TJR
12/29/16
1 OF 1
6 INITIAL BACKFILL JAB 04/02/20
4" FOR 12"-24" PIPE
6" FOR 30"-60" PIPE
MIN. COVER TO
RIGID PAVEMENT, H
MIN. COVER TO
FLEXIBLE PAVEMENT, H
RECOMMENDED MINIMUM TRENCH WIDTHS
© 2020 ADS, INC
MINIMUM RECOMMENDED COVER BASED ON
VEHICLE LOADING CONDITIONS**
* VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER
**SEE BACKFILL REQUIREMENTS IN NOTE 6.
NOTES:
1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE
FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW
APPLICATIONS", LATEST ADDITION
2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL,
WHEN REQUIRED.
3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A
DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE
ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH
BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL.
4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II OR III. THE CONTRACTOR SHALL PROVIDE
DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE
ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm)
FOR 30"-60" (750mm-1500mm).
5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II OR III IN THE PIPE ZONE EXTENDING TO
THE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL
SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST
EDITION.
6. MINIMUM COVER: MINIMUM COVER, H, IN NON-TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS)
IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO
PREVENT FLOTATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE
AND 24" OF COVER FOR 60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE
PAVEMENT OR TO TOP OF RIGID PAVEMENT. FOR TRAFFIC APPLICATIONS WITH LESS THAN FOUR FEET
OF COVER, EMBEDMENT OF THE PIPE SHALL BE USING ONLY A CLASS I OR CLASS II BACKFILL.
PIPE DIAM.MIN. TRENCH WIDTH
4"21"
(100mm)(533mm)
6"23"
(150mm)(584mm)
8"26"
(200mm)(660mm)
10"28"
(250mm)(711mm)
12"30"
(300mm)(762mm)
15"34"
(375mm)(864mm)
18"39"
(450mm)(991mm)
24"48"
(600mm)(1219mm)
30"56"
(750mm)(1422mm)
36"64"
(900mm)(1626mm)
42"72"
(1050mm)(1829mm)
48"80"
(1200mm)(2032mm)
60"96"
(1500mm)(2438mm)
SURFACE LIVE LOADING CONDITION
PIPE DIAM.H-25 HEAVY CONSTRUCTION
(75T AXLE LAOD) *
12" - 48"12" 48"
(300mm - 1200mm)(305mm)(1219mm)
60"24" 60"
(1500mm)(610mm)(1524mm)
FINAL
BACKFILL
INITIAL
BACKFILL
HAUNCH
BEDDING
SUITABLE
FOUNDATION
SPRINGLINE
MIN. TRENCH WIDTH
(SEE TABLE)
MAXIMUM RECOMMENDED COVER BASED
ON VECHICLE LOADING CONDITIONS
FILL HEIGHT TABLE GENERATED USING AASHTO SECTION 12,
LOAD RESISTANCE FACTOR DESIGN (LRFD) PROCEDURE WITH
THE FOLLOWING ASSUMPTIONS:
NO HYDROSTATIC PRESSURE,
UNIT WEIGHT OF SOIL (Ys) = 120 PCF
PIPE DIAM.
CLASS I CLASS II CLASS III
COMPACTED DUMPED 95%90%95%
4"37 18 25 18 18
(100mm)(11.3m)(5.5m)(7.6m)(5.5m)(5.5m)
6"44 20 29 20 21
(150mm)(13.4m)(6.1m)(8.8m)(6.1m)(6.4m)
8"32 15 22 15 16
(200mm)(9.8m)(4.6m)(6.7m)(4.6m)(4.9m)
10"38 18 26 18 18
(250mm)(11.6m)(5.5m)(7.9m)(5.5m)(5.5m)
12"35 17 24 17 17
(300mm)(10.7m)(5.2m)(7.3m)(5.2m)(5.2m)
15"38 17 25 17 18
(375mm)(11.6m)(5.2m)(7.6m)(5.2m)(5.5m)
18"36 17 24 17 17
(450mm)(11.0m)(5.2m)(7.3m)(5.2m)(5.2m)
24"28 13 20 13 14
(600mm)(8.5m)(4.0m)(6.1m)(4.0m)(4.3m)
30"28 13 20 13 14
(750mm)(8.5m)(4.0m)(6.1m)(4.0m)(4.3m)
36"26 12 18 13 13
(900mm)(7.9m)(3.7m)(5.5m)(4.0m)(4.0m)
42"23 11 16 11 11
(1050mm)(7.0m)(3.4m)(4.9m)(3.4m)(3.4m)
48"25 11 17 11 12
(1200mm)(7.6m)(3.4m)(5.2m)(3.4m)(3.7m)
60"25 11 17 11 12
(1500mm)(7.6m)(3.4m)(5.2m)(3.4m)(3.7m)
EXPANSION
MATERIAL
5 8" GALV.
STEEL
PLATE
EDGE OF
STREET
12" R 12" R
2' OPENING 3'-3"3'-3"
6"
(
T
Y
P
.
)
BACK
OF
CURB
SLOPE PLATE TO
MATCH SIDEWALK
BACK OF CURB
EDGE OF STREET
5 8" GALV. STEEL PLATE
2
1
2
1
3"x2"x3 8" GALV. ANGLE
SEE DETAIL 1
#4@12"
O.C.
#4@12"
O.C.
#4@12"
O.C.
6"
VARIES
2'
3'
SECTION B-B
SECTION A-A
PLAN
SECTION C-C
SLOPE
VARIES 0.5% SLOPE (MIN.)
3" (TYP.)
3' (TYP.)
SIDEWALK
(TYP.)
EXTEND WALK 6" ON
BOTH SIDES OF WALK
VA
R
I
E
S
VA
R
I
E
S
SL
O
P
E
CC
BB
A
A
2' DEPRESSED GUTTER
VA
R
I
E
S
8'-6"
EXPANSION
MATERIAL
3
8" BRASS SCREW 18" O.C.
WITH COUNTERSINK
HEAD FLUSH WITH PLATE
2'
2" MIN.
VARIES VARIES
2'
6"
6"
E
E
FF
PLAN
END VIEW
F
PLAN
F
SEE FIGURE 1 OF AASHTO
M 206 FOR ACTUAL SIZES
SECTION F-F END VIEW
3/4 IN. GALVANIZED ANCHOR BOLTS, NUTS AND WASHERS,
MILD STEE, ASTM A 307. ROD LUG SHALL BE COATED
WITH COAL - TAR EPOXY PAINT OR APPROVED EQUAL.
3/4 IN. "CANOPY" TYPE ROD LUG, OR
APPROVED, EQUAL
-+
60°Max. 30 Min.°
PIPE
DIAMETER F
18 IN. - 30 IN.
36 IN. - 42 IN.48 IN. - 60 IN.
72 IN. - 84 IN.
5 IN.
6 IN.7 IN.
9 IN.
CONCRETE JOINT
FASTENER
LOCATION OF 1''
DIA. HOLES
END SECTION FOR REINFORCED CONCRETE
CIRCULAR PIPE
END SECTION FOR REINFORCED
CONCRETE ELLIPTICAL PIPE
END SECTION FOR REINFORCED
CONCRETE ARCH PIPE
DIMENSIONS
A B C D E
PIPE
I.D.
IN.
12
15
18
24
30
36
42
48
54
60
72
5 1/2
7
11 1/2
12
17
18
24
28
27
36
34 1/2
23
26
26
4353
60
61
70
65
58
75
49
47
48
54
43
37
36
28
35
40
21
72
73
74
97
96
97
97
98
100
98
96
24
29
36
48
60
71
78
84
90
96
108
IN.IN.IN.IN.IN.
SECTION F-F
24
30
3642
48
54
60
30
38
4553
60
68
76
19
24
2934
38
43
48
8 1/2
9 1/2
11 1/815 3/4
21
25 1/2
30
39
54
6060
60
60
60
33
18
2436
36
36
36
72
72
8496
96
96
96
48
60
7278
84
90
96
(INCHES)EQUIVALENTCIRCULARDIAM. (IN.)
NOMINAL (IN.)DIMENSIONS
SPAN RISE A B C D E
24
30
36
48
54
DIAM. (IN.)
CIRCULAR
EQUIVALENT
42
60
72
96
96
96
96
96
(INCHES)
96
8 1/2
9 1/2
11 1/8
25 1/2
A
DIMENSIONS
15 3/4
RISESPAN
30
21
NOMINAL (IN.)
CB
60
60
60
60
50
60
39
36
36
36
36
46
35
33
78
90
96
84
D
60
72
48
E
29
36
43
50
58
65
72
86
18
22
27
31
36
40
44 31 12099396072
PLAN
SECTION X-X
GENERAL NOTES:
END VIEW
1.REVISED CDOH M-603-10
2.CONCRETE END SECTIONS ARE TO BE FURNISHED WITH
TOUGE OR GROOVE AS REQUIRED.
3.INSIDE CONFIGURATION AND JOINT OF CONCRETE END
SECTION AND PIPE SHALL MATCH.
4.CONCRETE PIPE JOINT FASTENERS, WHERE SHOWN ON PLANS,
SHALL BE INSTALLED SO THAT A MINIMUM OF 15 LINEAR FEET
OF THE OUTLET END OF THE ARE MECHANICALLY LOCKED
TOGETHER. END SECTION LENGHTS, WHEN USED, WILL BE
INCLUDED IN THE 15 L.F. REQUIRED.
E
BC
A
D
RISE
SPAN
SPAN
RISEA
D
E
ED
A
DIA.
BC
E
3''
F
2' - 5''
F
5''
5''
2' - 7''
3''
802 TYPICAL SIDEWALK CHASE
801 PIPE FOREBAY DETAIL
Forebay/
Rain
Garden
Basin
WQCV
Forebay Design
Volume (ft3)
Forebay
Depth
Forebay
Length
Forebay
Width
Forebay
Area Release (cfs)Pipe Size
(ft3)1% of WQCV (ft)(ft)(ft)(ft2)2% of Q100 (in)
A 1798 17.98 1 4.5 4 18 0.40 2.5
B 1361 13.61 1 3.5 4 14 0.29 2
C 2209 22.09 1 6 4 24 0.55 3
D 1183 11.83 1 6 2 12 0.29 2
M 2338 23.38 1 6 4 24 0.53 3
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
ST
O
R
M
D
R
A
I
N
D
E
T
A
I
L
S
62
N/A
N/A
C 805
3099CGSL
REV C7001-110-022DWG NO.1 OF 1SHEET1:12SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
30 IN STANDARD LOCKING GRATE ASSEMBLY -
TYPE B
TITLE
PROJECT NO./NAME
MATERIAL
DATE
REVISED BY
6-29-00DATE
AWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
2-10-10
EBC
30" GRATE FRAME
30" STANDARD GRATE
5/16-18 X 1 5/8" LONG HEX BOLT
ZINC-PLATED STEEL 2 PLACES
DRILL Ø .343 THRU GRATE ONLY
COUNTERBORE Ø 1.00 X .22 DP
2 PLACES
DRILL Ø .257 THRU
TAP 5/16-18 THREAD
2 PLACES
NOTE: LOCATION OF LOCKING DEVICE MAY VARY
©2010 NYLOPLASTREVE7001-110-042DWG NO.1 OF 1SHEET1:40SCALEDWG SIZE A
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
FAX (770) 932-2490
www.nyloplast-us.com
8 IN - 36 IN TYPICAL INSTALLATION OPTIONS
TITLE
PROJECT NO./NAME
MATERIAL
DATE
REVISED BY
8-10-00DATE
AWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER,
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
11-2-18
NMH
DU
C
T
I
L
E
I
R
O
N
DO
N
O
T
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NY
L
O
P
L
A
S
T
TSALPOLYN
D UCT I L E I R O N
TSA
L
PO
L
Y
N
D UC
T
I
L
E
I
RO
N
DU
C
T
I
L
E
I
R
O
N
DO
N
O
T
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NY
L
O
P
L
A
S
T
WHEN ARE DRAIN BASINS USED?
2808AG _ _ X
2810AG _ _ X
2812AG _ _ X
2815AG _ _ X
2818AG _ _ X
2824AG _ _ X
2830AG _ _ X
2836AG _ _ X
WHEN ARE INLINE DRAINS USED?
2708AG _ _ X
2710AG _ _ X
2712AG _ _ X
2715AG _ _ X
2718AG _ _ X
2724AG _ _ X
2730AG _ _ X
TYPICAL INSTALLATIONS
TYPICAL INSTALLATION OF NYLOPLAST
DRAIN BASIN AND INLINE DRAIN
1: TO ENTER AN EXISTING LINE
USING A TEE & RISER
2: AT THE BEGINNING OF A DRAIN LINE
USING AN ELBOW & RISER
TEE ELBOW
12" DRAIN BASIN
(2) INLET & OUTLET
ADAPTERS CAN BE
PUT ON ANY ANGLE
1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW
APPLICATIONS 5: TO CHANGE DIRECTION
A°
RISER
DRAIN BASIN
INLINE DRAIN
10" INLINE DRAIN
10" INLINE DRAIN
(3) VARIABLE ELEVATION
WATERTIGHT ADAPTERS AVAILABLE
FOR MOST COMMON PLASTIC PIPING SYSTEMS
8"6"
CORRUGATED
HDPE PIPE SMOOTH WALL
PVC
1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 36"
2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS
RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS
SEE DRAWING NO. 7001-110-065
4 - REDUCING CONES DOWN TO 30" DIAMETER WILL BE REQUIRED FOR 36"
DRAIN BASINS.
©2010 NYLOPLAST
1.CONTRACTOR SHALL INSTALL BIORETENTION BASINS ACCORDING TO THE APPROVED PLANS AND/OR
CONSTRUCTION SPECIFICATIONS.
2.PRE-CONSTRUCTION
2.1.CONTRACTOR SHALL AVOID COMPACTION OF THE BIORETENTION BASIN AREA TO PRESERVE EXISTING
INFILTRATION RATES.
2.2.CONTRACTOR SHALL CALL FOR CITY INSPECTIONS AT THE INTERVALS STIPULATED IN THE "DURING
CONSTRUCTION INSPECTION CHECKLISTS".
3.DURING CONSTRUCTION:
3.1.CONTRACTOR SHALL PROVIDE CONSTRUCTION OBSERVATION DURING CONSTRUCTION OF THE BIORETENTION
BASIN TO ENSURE COMPLIANCE WITH THE APPROVED PLANS AND DESIGN SPECIFICATIONS.
3.2.LOOSE MATERIALS SHALL NOT BE STORED ON THE BIORETENTION AREA.
3.3.THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT,
DEBRIS AND DIRT FROM ANY SOURCE FROM ENTERING THE BIORETENTION SYSTEM.
4.GEOTEXTILE LINERS:
4.1.WHERE USED, GEOTEXTILE LINERS (PERMEABLE OR IMPERMEABLE AS PER PLAN) SHALL BE INSTALLED ALONG
PERIMETER OF CROSS-SECTION OF THE BIORETENTION CELL.
4.2.WHERE USED, GEOTEXTILE LINERS SHALL BE PLACED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND
RECOMMENDATIONS. ALL SEAMS AND OPENINGS IN THE LINER SHALL BE SEALED ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS.
4.3.WHERE USED, IMPERMEABLE GEOMEMBRANE SHEET / LINER SHALL BE 40 MIL THICK, HIGH-DENSITY
POLYETHYLENE DESIGNED SPECIFICALLY FOR FLEXIBLE GEOMEMBRANE APPLICATIONS. ADJACENT STRIPS OF
IMPERMEABLE LINER SHALL OVERLAP A MINIMUM OF 18", OR PER MANUFACTURER'S SPECIFICATION.
4.4.WHERE USED, CONTRACTOR TO PLACE LINER IN A WAY THAT ENSURES ENOUGH SLACK IN THE LINER TO ALLOW
FOR BACKFILL AND SETTLING WITHOUT TEARING THE LINER.
5.AGGREGATES AND BSM:
5.1.ALL AGGREGATES SHALL BE ANGULAR, CRUSHED, WASHED ROCK, CLEAN OF DEBRIS AND WITH NO MORE THAN
1% FINES.
5.2.RESERVOIR AGGREGATE SHALL BE GRADATION ASTM #57 OR #67.
5.3.DIAPHRAGM AGGREGATE SHALL BE "PEA GRAVEL", WITH GRADATION ASTM #8, #89 OR #9.
5.4.THE BIORETENTION SOIL SHALL MEET THE CITY BIORETENTION SAND MEDIA ("BSM") SPECIFICATION FOUND
AT:https://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulations/
NOTES:
12" MAX
1
MAXIMUM ALLOWABLE
PONDING DEPTH IS 12"
FROM THE TOP OF THE
MULCH
4 MAX
PONDING DEPTH MUST
NOT EXCEED FLOWLINE
ELEVATION OF ADJACENT
GUTTER8" MIN DEPTH THICKENED
CURB ADJACENT TO
VEHICULAR PAVEMENTS
OVERFLOW
RISER OPTION
(AS PER PLAN)
8" MIN DEPTH
THICKENED CURB
ADJACENT TO
VEHICULAR
PAVEMENTS
STANDARD CROSS-SECTION
1
2
WALLED CROSS-SECTION
PONDING DEPTH MUST
NOT EXCEED FLOWLINE
ELEVATION OF ADJACENT
GUTTER
18" MIN
4"
12" MAX
30" MIN
36" MIN
BASIN WIDTH
COVER PLATE
8"
SIDEWALK CHASE
18" MIN
OVERFLOW RISER
OPTION (AS PER PLAN)
REINFORCED
CONCRETE WALLS (AS
PER PLAN)
4" MIN DEPTH OF
DIAPHRAGM AGGREGATE
8" MIN DEPTH OF
RESERVOIR AGGREGATE
18" MIN DEPTH OF
BIORETENTION SAND MEDIA
MAXIMUM ALLOWABLE
PONDING DEPTH IS 12"
FROM THE SURFACE OF
THE MULCH
4" MIN DIAMETER
PERFORATED PVC
UNDERDRAIN
6.UNDERDRAIN:
6.1.UNDERDRAIN PIPE TO BE PERFORATED OR SLOTTED. PERFORATIONS OR SLOTS TO BE SMALLER THAN SURROUNDING AGGREGATE TO ENSURE AGGREGATE DOES NOT FALL INTO OR
CLOG THE OPENINGS.
6.2.DO NOT WRAP UNDERDRAIN WITH GEOTEXTILE OR SOCK.
6.3.UNDERDRAIN PIPE MUST OUTFALL BY GRAVITY AND MUST TIE INTO A STORMWATER PIPE, INLET OR SYSTEM AND THE LOCATION MUST BE APPROVED BY THE CITY. THE UNDERDRAIN
TIE-IN SHALL MEET ALL REQUIRED PIPE SIZE, TYPES, AND COVER REQUIREMENTS THAT MAY APPLY TO PIPING THAT EXTENDS BEYOND THE LIMITS OF THE BIORETENTION CELL AND
ENCROACHES INTO PUBLIC RIGHT-OF-WAY OR OTHER PROPERTY.
7.OVERFLOW INLET:
7.1.A 100-YEAR OVERFLOW SPILLWAY OR INLET MUST BE PROVIDED.
7.2.ALL OVERFLOW INLETS SHALL BE CAPPED WITH A DOME-SHAPED GRATE, OR PER PLAN.
7.3.IN ALL CASES, AN EMERGENCY OVERFLOW ROUTE SHALL BE PROVIDED AND THE LOCATION SHALL BE IDENTIFIED ON THE PLANS (THIS MAY BE COINCIDENT WITH THE 100-YEAR
OVERFLOW SPILLWAY).
8.CLEANOUTS:
8.1.PROVIDE CLEANOUTS (AS PER PLAN) TO ALLOW INSPECTION (BY CAMERA) OF THE UNDERDRAIN SYSTEM DURING AND AFTER CONSTRUCTION.
8.2.CLEANOUTS SHALL BE PROVIDED AT EACH BEND GREATER THAN OR EQUAL TO 90° AND EVERY 100' ALONG A STRAIGHT RUN. CLEANOUT SHALL BE INSTALLED PER THE APPROVED
PLANS.
8.3.CLEANOUTS SHALL BE A SOLID WALL PVC STRUCTURE FOR ALL VERTICAL SECTIONS WITH FITTINGS TO CONNECT TO DISTRIBUTION AND UNDERDRAIN PIPING MATERIALS, AS
REQUIRED.
9.FOREBAY:
9.1.THE FOREBAY SHALL BE EASILY ACCESSIBLE WITH A HARD SURFACED BOTTOM FOR MAINTENANCE PURPOSES.
10.LANDSCAPE MATERIALS
10.1.CONTRACTOR SHALL NOT PLACE WEED BARRIER ANYWHERE WITHIN THE BIORETENTION BASIN. IF MULCH IS PLACED IN THE BIORETENTION BASIN, IT MUST BE NON-FLOATABLE.
10.2.IF MULCH OR COBBLES ARE PLACED IN THE BIORETENTION BASIN, THE MAXIMUM ALLOWABLE WATER DEPTH OF 12" AND REQUIRED BASIN VOLUME MUST BE MEASURED FROM THE
TOP SURFACE OF THE MULCH OR COBBLE.
10.3.ROLLED TURF OR SOD IS NOT AN ALLOWABLE LANDSCAPE MATERIAL FOR BIORETENTION BASINS. LOW WATER CONSUMPTION LANDSCAPE PLANTINGS ARE PREFERRED FOR
BIORETENTION BASINS.
10.4.LANDSCAPE PLANTINGS SHALL NOT BE PLACED TO IMPEDE DRAINAGE INTO OR OUT OF THE BIORETENTION BASIN.
10.5.TEMPORARY IRRIGATION MAY BE INSTALLED TO ESTABLISH LANDSCAPING OR SEED IN THE BIORETENTION BASIN.
2" MIN
8" MIN
4"
FLAT
FOREBAY IS REQUIRED TO
BE PLACED AT
CONCENTRATED INFLOW
LOCATIONS; PER PLANS
AND SITE SPECIFIC
DETAILS
LANDSCAPING TO BE
INSTALLED PER
APPROVED
LANDSCAPING PLAN
6"-12"
4" MIN DEPTH OF
DIAPHRAGM AGGREGATE
8" MIN DEPTH OF
RESERVOIR AGGREGATE
8" MIN 4" MIN DIAMETER
PERFORATED PVC
UNDERDRAIN
2" MIN
30" MIN
GEOTEXTILE
FABRIC OR LINER
(AS PER PLAN)18" MIN DEPTH OF
BIORETENTION SAND
MEDIA
NATIVE SOIL
ZONE
RUNDOWN OR SCOUR
PROTECTION NEEDED
ON SLOPES
8"
FLAT AREA - SEE DESIGN
PLANS FOR EXTENTS OF
BIORETENTION FLAT
SURFACES
PART 1 - GENERAL
A. Bioretention Sand Media (BSM) shall be uniformly mixed, uncompacted, free of stones, stumps, roots, or other similar objects larger than two inches. No other materials or substances shall be mixed or dumped within the bioretention area that
may be harmful to plant growth or prove a hindrance to the facility’s function and maintenance.
B. BSM shall be free of plant or seed material of non-native, invasive species, or weeds.
C. Fully mixed BSM shall be tested prior to installation and meet the following criteria:
1. P-Index of less than 30
2. pH of 5.5-6.5. Should pH fall outside of the acceptable range, it may be modified with
lime (to raise) or iron sulfate plus sulfur (to lower). The lime or iron sulfate must be mixed
uniformly into the BSM prior to use in the bioretention facility.
3. Cation Exchange Capacity (CEC) greater than 10
4. Phosphorous (Phosphate, P2O5) not to exceed 69 ppm
5. BSM that fails to meet the minimum requirements shall be replaced at the Contractor’s
expense.
D. BSM shall be delivered fully mixed in a drum mixer. Onsite mixing of piles will not be allowed. Mixing of the BSM to a homogeneous consistency shall be done to the satisfaction of the Owner.
PART 2 - SOIL MATERIALS
A. Sand
1. BSM shall consist of 60% sand by volume meeting ASTM C-33.
B. Shredded Cedar Mulch
1. BSM shall consist of 5% shredded cedar mulch by volume.
2. Shredded mulch shall be loosely packed, approximate bulk density of 50-100 lbs/CY.
C. Topsoil
1. BSM shall consist of 30% topsoil by volume.
2. Topsoil shall be classified as sandy loam, loamy sand, or loam per USDA textural triangle with less than 5% clay material.
3. Onsite, native material shall not be used as topsoil.
4. Textural analysis shall be performed on topsoil, preferably at its source, prior to including topsoil in the mix. Topsoil shall be free of subsoil, debris, weeds, foreign matter, and any other material deleterious to plant health.
5. Topsoil shall have a pH range of 5.5 to 7.5 and moisture content between 25-55%.
6. Contractor shall certify that topsoil meets these specifications.
D. Leaf Compost
1.BSM shall consist of 5% leaf compost by volume.
2.Leaf compost shall consist of Class 1 organic leaf compost consisting of aged leaf mulch resulting from biological degradation and transformation of plant-derived materials under controlled conditions designed to promote aerobic
decomposition.
3. The material shall be well composted, free of viable weed seeds and contain material of a generally humus nature capable of sustaining growth of vegetation, with no materials toxic to plant growth.
4.Compost shall be provided by a local US Composting Council Seal of Testing Assurance member. A copy of the provider’s most recent independent STA test report shall be submitted to and approved by the Owner prior to delivery of BSM
to the project site.
5.Compost material shall also meet the following criteria:
a.100 percent of the material shall pass through a 1/2 inch screen
b.PH of the material shall be between 6.0 and 8.4
c.Moisture content shall be between 35 and 50 percent
d.Maturity greater than 80 percent (maturity indicator expressed as percentage of germination/vigor, 80+/80+)
e.Maturity indicator expressed as Carbon to Nitrogen ration < 12
f.Maturity indicator expressed as AmmoniaN/NitrateN Ratio <4
g.Minimum organic matter shall be 40 percent dry weight basis
h.Soluble salt content shall be no greater than 5500 parts per million or 0-5 mmhos/cm
i.Phosphorus content shall be no greater than 325 parts per million
j.Heavy metals (trace) shall not exceed 0.5 parts per million
k.Chemical contaminants: meet or exceed US EPA Class A standard, 40 CFR 503.13, Tables 1 & 3 levels
l.Pathogens: meet or exceed US EPA Class A standard, 40 CFR 503.32(a) levels
PART 3 - EXECUTION
A.General
1.Refer to project specifications for excavation requirements.
B.Placement Method
1.BSM material shall be spread evenly in horizontal layers.
2.Thickness of loose material in each layer shall not exceed 9-inches.
3.Compaction of BSM material is not required.
803 BIORETENTION SAND MEDIA SPECIFICATIONS
EXAMPLE ONLY
SEE INLET SCHEDULE
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
806 OUTLET STRUCTURE 100-YEAR ORIFICE PLATE
ST
O
R
M
D
R
A
I
N
D
E
T
A
I
L
S
63
N/A
N/A
C 806
CC
A
A
B
B
SECTION C-C
SECTION A-A SECTION B-B
WELL SCREEN FLOW CONTROL PLATE
PLAN
GENERAL NOTES
SECTION D-D
D
D
A A
ABBREVIATIONS
LEGEND
Inlet Schedule
Inlet Design Point Contributing
Basin Inlet Type Inlet Size Q2 Flow Q100 Flow
1-1 c Pond 1 & 2 Type-C 3' x 3'3.6 3.6
1-2 c Basin C / Pond 2 Pond 2 Outlet
Structure See Detail 2.4 2.4
2-1 f Basin F Type-R 5'0.26 1.13
2-2 g Basin G Type-R 5'0.3 1.32
3-1 c Basin C Type-D 3' x 6'6.29 27.47
3-2.1 h Basin H Type-R 5'0.76 3.13
3-2.2 i Basin I Type-R 5'0.97 4.24
3-3.1 e Basin E / Pond 1 Pond 1 Outlet
Structure See Detail 1.2 1.2
3-4 d Basin D Type-C 3' x 3'3.29 14.35
3-5 m Basin M Type-C 3' x 3'6.08 26.54
3-6 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-6.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-7 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-7.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-8 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-8.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-9 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-9.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-10 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-10.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-11 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-11.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-12.1 l Basin L Area Inlet 8" Dome 0.0963 0.385
3-13 l Basin L Area Inlet 8" Dome 0.0963 0.385
4-1 j Basin J Type-R 5'0.78 3.39
4-2 k Basin K Type-R 5'1.07 4.67
5-2.1 a Basin A Type-C 3' x 3'4.53 19.75
6-8 b Basin B Type-C 3' x 3'3.4 14.65
6-2.6 e Basin E Type-R 5'7.61 12.3
6-3.1 n/a Area Inlets around
Building 3 Area Inlet 8" Dome N/A 0.94
6-4.1 n/a Bldg 3 Area Inlet 8" Dome N/A 0.94
6-5.1 n/a Bldg 3 Area Inlet 8" Dome N/A 0.94
6-6.1 n/a Bldg 3 Area Inlet 8" Dome N/A 0.94
6-6.2 n/a Bldg 3 Area Inlet 8" Dome N/A 0.94
Outlet Structure Details
Detail Pond 1 Pond 2
ELEV A 4937.00 4935.00
ELEV B 4938.00 4936.19
ELEV C 4939.00 4937.19
Dwq (ft)N/A 1.19
Ls (ft)4 4
Ws (ft)4 4
Wo (in)3 3
WQ HOLE DIA (in)N/A 1-1/16
# ROWS N/A 3
# COLUMNS N/A 1
100-YR RESTRICTOR
DIA (in)3.15 6.35
PLATE CENTERED
OVER PIPE OPENING
IN WALL
5
16" THICK
GALVANIZED
STEEL PLATE
ORIFICE OPENING
(X" Ø, POND 1)
(X" Ø, POND 1)
1
2" Ø HOLES FOR 3
8"
EXPANSION BOLTS
EMBEDDING 2" INTO
CONCRETE WALL @
6" O.C. MIN.
D + 4"
D
D+ 4"
ORIFICE INVERT SHALL MATCH
PIPE INVERT
805 NATURALIZED TRICKLE PAN WITH 4" UNDERDRAIN
4" PERFORATED PIPE
8"
MIN
12" MIN
SIDE SLOPE VARIES
8" MIN
8"
MIN
50% SAND / 50% TOPSOIL
PEA GRAVEL
804 CONCRETE C-CHANNEL TO RAIN GARDEN
2' CHANNEL BOTTOM
6" CURBHEAD
NATURALIZED AREA SURROUNDING CHANNEL
SEE LANDSCAPING PLANS PER RIPLEY DESIGNS
6"
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
ST
O
R
M
D
R
A
I
N
D
E
T
A
I
L
S
64
N/A
N/A
C 807
ACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS
PLEASE NOTE:
1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE".
2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR.
3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR
COMPACTION REQUIREMENTS.
4.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION.
NOTES:
1.CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
2.SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS".
3.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH
CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS.
4.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS.
5.REQUIREMENTS FOR HANDLING AND INSTALLATION:
·TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS.
·TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 2”.
·TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT SHALL BE GREATER THAN OR EQUAL TO 550 LBS/FT/%. THE ASC IS DEFINED IN SECTION 6.2.8
OF ASTM F2418. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR
YELLOW COLORS.
MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL
CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT
D
FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C'
LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED
GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D'
LAYER.
ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.N/A
PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND
PREPARATION REQUIREMENTS.
C
INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE
EMBEDMENT STONE ('B' LAYER) TO 18" (450 mm) ABOVE THE TOP OF THE
CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C'
LAYER.
GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR
PROCESSED AGGREGATE.
MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS
LAYER.
AASHTO M145¹
A-1, A-2-4, A-3
OR
AASHTO M43¹
3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10
BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER
THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN
6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR
WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR
PROCESSED AGGREGATE MATERIALS. ROLLER GROSS
VEHICLE WEIGHT NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC
FORCE NOT TO EXCEED 20,000 lbs (89 kN).
B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE
FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE.CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED.
A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO
THE FOOT (BOTTOM) OF THE CHAMBER.CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹
3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3
18"
(450 mm) MIN*
8'
(2.4 m)
MAX
6" (150 mm) MIN
D
C
B
A
12" (300 mm) MIN 12" (300 mm) TYP51" (1295 mm)6"
(150 mm) MIN
30"
(760 mm)
DEPTH OF STONE TO BE DETERMINED
BY SITE DESIGN ENGINEER 6" (150 mm) MIN
*TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED
INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR,
INCREASE COVER TO 24" (600 mm).
PAVEMENT LAYER (DESIGNED
BY SITE DESIGN ENGINEER)
SC-740
END CAP
EXCAVATION WALL (CAN
BE SLOPED OR VERTICAL)
PERIMETER STONE
(SEE NOTE 4)
SUBGRADE SOILS
(SEE NOTE 3)
ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL
AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W X H X INSTALLED LENGTH)51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm)
CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³)
MINIMUM INSTALLED STORAGE*74.9 CUBIC FEET (2.12 m³)
WEIGHT 75.0 lbs.(33.6 kg)
*ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS
SC-740 TECHNICAL SPECIFICATION
NTS
BUILD ROW IN THIS DIRECTION
OVERLAP NEXT CHAMBER HERE
(OVER SMALL CORRUGATION)
START END
90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH
A A
C
B
51.0"
(1295 mm)
30.0"
(762 mm)
45.9" (1166 mm)12.2"
(310 mm)
29.3"
(744 mm)
PART #STUB A B C
SC740EPE06T / SC740EPE06TPC 6" (150 mm)10.9" (277 mm)18.5" (470 mm)---
SC740EPE06B / SC740EPE06BPC ---0.5" (13 mm)
SC740EPE08T /SC740EPE08TPC 8" (200 mm)12.2" (310 mm)16.5" (419 mm)---
SC740EPE08B / SC740EPE08BPC ---0.6" (15 mm)
SC740EPE10T / SC740EPE10TPC 10" (250 mm)13.4" (340 mm)14.5" (368 mm)---
SC740EPE10B / SC740EPE10BPC ---0.7" (18 mm)
SC740EPE12T / SC740EPE12TPC 12" (300 mm)14.7" (373 mm)12.5" (318 mm)---
SC740EPE12B / SC740EPE12BPC ---1.2" (30 mm)
SC740EPE15T / SC740EPE15TPC 15" (375 mm)18.4" (467 mm)9.0" (229 mm)---
SC740EPE15B / SC740EPE15BPC ---1.3" (33 mm)
SC740EPE18T / SC740EPE18TPC 18" (450 mm)19.7" (500 mm)5.0" (127 mm)---
SC740EPE18B / SC740EPE18BPC ---1.6" (41 mm)
SC740ECEZ*24" (600 mm)18.5" (470 mm)---0.1" (3 mm)
ALL STUBS, EXCEPT FOR THE SC740ECEZ ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE
STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT
1-888-892-2694.
* FOR THE SC740ECEZ THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm).
BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.
NOTE: ALL DIMENSIONS ARE NOMINAL
PRE-FAB STUB AT BOTTOM OF END CAP WITH FLAMP END WITH "BR"
PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"
PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"
PRE-CORED END CAPS END WITH "PC"
SC-740 ISOLATOR ROW PLUS DETAIL
NTS
SC-740 END CAP
OPTIONAL INSPECTION PORT
SC-740 CHAMBER
STORMTECH HIGHLY RECOMMENDS
FLEXSTORM INSERTS IN ANY UPSTREAM
STRUCTURES WITH OPEN GRATES
ONE LAYER OF ADSPLUS125 WOVEN GEOTEXTILE BETWEEN
FOUNDATION STONE AND CHAMBERS
5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS
ELEVATED BYPASS MANIFOLD
24" (600 mm) HDPE ACCESS PIPE REQUIRED
USE EZ END CAP PART #: SC740ECEZ
INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE
PART#: SC74024RAMP
NYLOPLAST
SUMP DEPTH TBD BY
SITE DESIGN ENGINEER
(24" [600 mm] MIN RECOMMENDED)
UNDERDRAIN DETAIL
NTS
A
A
B B
SECTION A-A
SECTION B-B
DUAL WALL
PERFORATED
HDPE
UNDERDRAIN
ADS GEOSYNTHETICS 601T
NON-WOVEN GEOTEXTILE
STORMTECH END CAP
ADS GEOSYNTHETICS 601T
NON-WOVEN GEOTEXTILE
STORMTECH
CHAMBER
OUTLET MANIFOLD
STORMTECH END CAP
STORMTECH
CHAMBERS
NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER
4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS
6" (150 mm) TYP FOR SC-740, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS
FOUNDATION STONE
BENEATH CHAMBERS
FOUNDATION STONE
BENEATH CHAMBERS
INSPECTION & MAINTENANCE
STEP 1)INSPECT ISOLATOR ROW PLUS FOR SEDIMENT
A.INSPECTION PORTS (IF PRESENT)
A.1.REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN
A.2.REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED
A.3.USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG
A.4.LOWER A CAMERA INTO ISOLATOR ROW PLUS FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL)
A.5.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
B.ALL ISOLATOR PLUS ROWS
B.1.REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW PLUS
B.2.USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW PLUS THROUGH OUTLET PIPE
i)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY
ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE
B.3.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3.
STEP 2)CLEAN OUT ISOLATOR ROW PLUS USING THE JETVAC PROCESS
A.A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED
B.APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN
C.VACUUM STRUCTURE SUMP AS REQUIRED
STEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS.
STEP 4)INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM.
NOTES
1.INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS
OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS.
2.CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY.
St
o
r
m
T
e
c
h
88
8
-
8
9
2
-
2
6
9
4
|
WW
W
.
S
T
O
R
M
T
E
C
H
.
C
O
M
®
Ch
a
m
b
e
r
S
y
s
t
e
m
46
4
0
T
R
U
E
M
A
N
B
L
V
D
HI
L
L
I
A
R
D
,
O
H
4
3
0
2
6
1-
8
0
0
-
7
3
3
-
7
4
7
3
DA
T
E
:
DR
A
W
N
:
A
S
PR
O
J
E
C
T
#
:
CH
E
C
K
E
D
:
N
/
A
RE
V
:
TH
I
S
D
R
A
W
I
N
G
H
A
S
B
E
E
N
P
R
E
P
A
R
E
D
B
A
S
E
D
O
N
I
N
F
O
R
M
A
T
I
O
N
P
R
O
V
I
D
E
D
T
O
A
D
S
U
N
D
E
R
T
H
E
D
I
R
E
C
T
I
O
N
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
O
R
O
T
H
E
R
P
R
O
J
E
C
T
R
E
P
R
E
S
E
N
T
A
T
I
V
E
.
T
H
E
S
I
T
E
D
E
S
I
G
N
E
N
G
I
N
E
E
R
S
H
A
L
L
R
E
V
I
E
W
T
H
I
S
D
R
A
W
I
N
G
P
R
I
O
R
T
O
C
O
N
S
T
R
U
C
T
I
O
N
.
I
T
I
S
T
H
E
U
L
T
I
M
A
T
E
R
E
S
P
O
N
S
I
B
I
L
I
T
Y
O
F
T
H
E
S
I
T
E
D
E
S
I
G
N
EN
G
I
N
E
E
R
T
O
E
N
S
U
R
E
T
H
A
T
T
H
E
P
R
O
D
U
C
T
(
S
)
D
E
P
I
C
T
E
D
A
N
D
A
L
L
A
S
S
O
C
I
A
T
E
D
D
E
T
A
I
L
S
M
E
E
T
A
L
L
A
P
P
L
I
C
A
B
L
E
L
A
W
S
,
R
E
G
U
L
A
T
I
O
N
S
,
A
N
D
P
R
O
J
E
C
T
R
E
Q
U
I
R
E
M
E
N
T
S
.
LA
N
D
I
N
G
@
L
E
M
A
Y
FO
R
T
C
O
L
L
I
N
S
,
C
O
,
U
S
A
SHEET
1 1OF
NO
T
T
O
S
C
A
L
E
ISOLATOR ROW PLUS
SEE DETAIL()
PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDING
STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL
CHAMBER INLET ROWS
BED LIMITS
PROPOSED ELEVATIONS:
MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):4849.75
MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):4843.75
MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):4843.25
MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):4843.25
MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):4843.25
TOP OF STONE:4842.25
TOP OF SC-740 CHAMBER:4841.75
12" x 12" TOP MANIFOLD INVERT:4840.29
12" BOTTOM CONNECTION INVERT:4839.35
24" ISOLATOR ROW PLUS INVERT:4839.26
BOTTOM OF SC-740 CHAMBER:4839.25
UNDERDRAIN INVERT:4838.75
BOTTOM OF STONE:4838.75
PROPOSED LAYOUT
32 STORMTECH SC-740 CHAMBERS
8 STORMTECH SC-740 END CAPS
6 STONE ABOVE (in)
6 STONE BELOW (in)
40 STONE VOID
2747
INSTALLED SYSTEM VOLUME (CF)
(PERIMETER STONE INCLUDED)
(COVER STONE INCLUDED)
(BASE STONE INCLUDED)
1332 SYSTEM AREA (SF)
171.1 SYSTEM PERIMETER (ft)
MAX FLOWINVERT*DESCRIPTIONITEM ON
LAYOUTPART TYPE
0.10"24" BOTTOM PREFABRICATED EZ END CAP, PART#: SC740ECEZ / TYP OF ALL 24" BOTTOM
CONNECTIONS AND ISOLATOR PLUS ROWSAPREFABRICATED EZ END CAP
INSTALL FLAMP ON 24" ACCESS PIPE / PART#: SC74024RAMPBFLAMP
12.50"12" x 12" TOP MANIFOLD, ADS N-12CMANIFOLD
4.6 CFS IN30" DIAMETER (24.00" SUMP MIN)DNYLOPLAST (INLET W/ ISO
PLUS ROW)
2.0 CFS OUT30" DIAMETER (DESIGN BY ENGINEER)ENYLOPLAST (OUTLET)
6" ADS N-12 DUAL WALL PERFORATED HDPE UNDERDRAINFUNDERDRAIN
D
E
A
B
C
18
.
5
0
'
58.53'
21
.
1
0
'
64.46'
1 SC-740 CROSS SECTION DETAIL
2 SC-740 TECHNICAL SPECIFICATION
3 SC-740 ISOLATOR ROW PLUS DETAIL
SPA
C
E
I
N
T
E
N
T
I
O
N
A
L
L
Y
L
E
F
T
B
L
A
N
K
4 UNDERDRAIN DETAIL
SPA
C
E
I
N
T
E
N
T
I
O
N
A
L
L
Y
L
E
F
T
B
L
A
N
K
NOTES
•MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.
•DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLD
COMPONENTS IN THE FIELD.
•THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.
•THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR
DETERMINING
THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION IS
PROVIDED.
•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.
*INVERT ABOVE BASE OF CHAMBER
F
WEIR TOP
ELEV. 4941.37'
WEIR ELEVATION 4941.37'
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
ST
R
E
E
T
D
E
T
A
I
L
S
65
N/A
N/A
C 808
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
ST
R
E
E
T
D
E
T
A
I
L
S
66
N/A
N/A
C 809
1 2 3
4
5 6 7
8
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PR
I
V
A
T
E
S
I
T
E
D
E
T
A
I
L
S
67
########
N/A
C 810
807 CONCRETE COLLAR
6"
R2"R2"
4"
4"
4"
OUTLET PIPE
FRONT VIEW SIDE VIEW
LIGHT DUTY PAVEMENT SECTION HEAVY DUTY PAVEMENT SECTION
ASPHALT
PAVEMENT SECTION
ASPHALT
PAVEMENT SECTION
PRIVATE CONCRETE
PAVEMENT SECTION
PRIVATE CONCRETE FLATWORK
PAVEMENT SECTION
PUBLIC CONCRETE FLATWORK
PAVEMENT SECTION
4" CONCRETE
6" CONCRETE
6"
CONCRETE
MINIMUM
4.0" HOT
BITUMINOUS
PAVEMENT
7" APPROVED
SUBGRADE
5.5" HOT
BITUMINOUS
PAVEMENT
6.6" HOT
BITUMINOUS
PAVEMENT
4.5" HOT
BITUMINOUS
PAVEMENT
8.0" HOT
BITUMINOUS
PAVEMENT
VEHICULAR PAVING SECTIONS
CONCRETE FLATWORK SECTIONS
NOTES:
ALL SITE GRADING, SUBGRADE PREPARATION AND PAVING SHALL FOLLOW THE GEOTECHNICAL RECCOMENDATIONS CONTAINED IN THE
GEOTECHNICAL ENGINEERING STUDY AND PAVEMENT THICKNESS DESIGN PROPOSED WATERMARK APARTMENTS AT LEMAY NEAR
NORTHEAST CORNER OF NORTH LEMAY AVENUE AND DUFF DRIVE FORT COLLINS, COLORADO" BY KUMAR & ASSOCIATES, INC. PROJECT
NO, 22-3-168 REVISED OCTOBER 19, 2023.
1.REFER TOP PLANS BY RIPLEY DESIGN, INC. FOR ADDITIONAL HARDSCAPE INFORMATION.
2.CONCRETE JOINTING SHALL CONFORM TO CDOT DETAIL M-412-1 OR APPROVED EQUAL.
3.NOTE THAT THESE PAVING SECTIONS ARE TO BE USED ONLY FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY. PAVING SECTIONS
WITHIN PUBLIC RIGHT-OF-WAY WILL BE REQUIRED BY THE CITY OF FORT COLLINS TO BE PER AN APPROVED PAVEMENT DESIGN
REPORT.
808 PAVING SECTIONS
9 10
11
12
OF
SCALE:
PROJECT NO.
PR
O
J
E
C
T
M
A
N
A
G
E
R
:
NO
.
RE
V
I
S
I
O
N
S
BY
:
DA
T
E
:
SU
B
M
I
T
T
A
L
D
A
T
E
:
SHEET:
HORIZ:
VERT:
CAUTION
The engineer preparing these
plans will not be responsible
for, or liable for, unauthorized
changes to or uses of these
plans. All changes must be
approved by the Professional
Engineer of these plans.
11
/
1
5
/
2
3
TH
E
L
A
N
D
I
N
G
A
T
L
E
M
A
Y
68
1791-003
D.
W
e
b
e
r
13
3
7
R
I
V
E
R
S
I
D
E
A
V
E
.
#
2
FO
R
T
C
O
L
L
I
N
S
,
C
O
8
0
5
2
4
AV
A
N
T
C
I
V
I
L
G
R
O
U
P
.
C
O
M
97
0
.
2
8
6
.
7
9
9
5
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
R
E
V
I
E
W
S
E
T
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PR
I
V
A
T
E
S
I
T
E
D
E
T
A
I
L
S
68
N/A
N/A
C 811