Loading...
HomeMy WebLinkAboutMASON STREET INFRASTRUCTURE PROJECT - FDP230016 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATION8" W 8" W 8" W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8 " W 8" W 8" W 12 " S S 12 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S E E E E E E E E E E E E E E E E E E E E E E E E E E 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 1 2 " S S 12" SS G G G G G G G G G G G E E E E E E E E E E E E E E EEEEE E T F TF S ELEC F ES M VAULT ELEC VAULT ELEC VAULT ELEC CABLE CABLE ELEC CTV CTV CTV OH U OH U OH U OH U X X X X X CT V CT V CT V CT V CTV CT V CTV CTV CTV OHU OHU X X X X X X X X X X X X X X CTV CTV CTV CT V CTV CTV CT V CTV CTV G G G G G G G G SS SS SS SS SS SS SS SS SS SS SS SS H2O H2O A RV H2O H2O D HYD S F E S F E S W W W W W W W W W W W W W W W W W W W XXXXXXXXXXXXX OHU OHU OHU OHU OHU X X X X X X X X W W W W W W W W W W W W W W W W W W W X X W W W W W S S SS SS SS SS SS SS SS D X X X X X W W W POC NO.1 TAP,METER, BACKFLOW SIZE: 1.5-INCH SERVICE LINE SIZE: 1.5-INCH PEAK DEMAND: 40 GPM AVAILABLE PRESSURE: X PSI -OR- REQUIRED PRESSURE: X PSI CONTROLLER 'A' 120 VAC POWER REQUIRED NATIVE SEED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM (TYP). SHRUB BEDS AND TREES AND SHRUBS IN NATIVE SEED WILL BE DRIP IRRIGATED WITH POINT SOURCE DRIP EMITTERS (TYP). SOD AREAS WILL BE IRRIGATED WITH EITHER SPRAY SPRINKLERS OR ROTOR SPRINKLERS ON 6" RISERS USING MATCHED PRECIPITATION RATE NOZZLES (TYP). M A LOT 2 NATIVE SEED WILL BE TEMPORARILY IRRIGATED UNTIL SUCH TIME THAT FULL BUILD OUT OCCURS. IRRIGATION POC WILL IRRIGATE BOTH LOTS 1 & 2 UNTIL LOT 1 NATIVE SEED IS ESTABLISHED, AT WHICH TIME LOT 1 SYSTEM WILL BE ABANDONED IN PLACE AND ISOLATION GATE VALVE SHUT. PROPOSED (1)4"&(2)3" SLEEVES SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER MODEL ICV 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION ISOLATION GATE VALVE ASSEMBLY MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. 1.5-INCH REDUCED PRESSURE BACKFLOW PREVENTER REFER TO DETAILED PLANS TWO-WIRE IRRIGATION CONTROL SYSTEM REFER TO DETAIL PLANS IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 REFER TO DETAILS PLANS FOR SIZING A IRRIGATION_SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Mi c h e l l e p e t e r s o n La y o u t : IR M P 1 . 0 Pr i n t e d O n : 12 / 2 0 / 2 0 2 3 9 : 1 4 A M Fi l e N a m e : MP - I R - M A S O N S T R E E T I N F R S T . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Klara Rossouw 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 NORTH COLLEGE 1311, LLC 262 E. Mountain Ave. Fort Collins, CO 80524 p. 970.490.2626 ENGINEER LAND PLANNER NORTHERN ENGINEERING Blaine Mathisen 301 N Howes St, Suite 100 Fort Collins, CO 80521 p. 970.221.4158 OWNER 1 PDP/FDP SUBMITTAL 12/20/23 IRRIGATION MASTER PLAN PDP/FDP SUBMITTAL MASON STREET INFRASTRUCTURE TEAM MLP R23-008 IRMP1.0 NORTH 0 25 50 100 SCALE: 1"=50'-0" MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com