HomeMy WebLinkAboutMASON STREET INFRASTRUCTURE PROJECT - FDP230016 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATION8"
W
8"
W
8"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8
"
W
8"
W
8"
W
12
"
S
S
12
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
E
E
E
E
E
E
E
E E E E E E E E E E E E E E E E E E E
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
1
2
"
S
S
12" SS
G
G
G
G
G
G
G
G
G
G
G
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEEE
E
T
F
TF
S
ELEC
F
ES
M VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
CABLE
CABLE ELEC
CTV CTV CTV
OH
U
OH
U
OH
U
OH
U
X
X X
X
X
CT
V
CT
V
CT
V
CT
V
CTV
CT
V
CTV CTV CTV
OHU OHU
X X
X X X X X X X
X
X
X
X
X
CTV CTV CTV
CT
V
CTV CTV
CT
V
CTV CTV
G G
G G G G G G
SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
H2O
H2O
A RV
H2O H2O
D
HYD
S
F E
S
F E S
W W W W W W W W W W W W W W W W W W W
XXXXXXXXXXXXX
OHU OHU OHU OHU OHU
X
X
X
X
X
X
X
X
W W W W W W W W W W W W W W W W W W W
X
X
W W W W W
S
S
SS
SS
SS
SS
SS
SS
SS
D
X
X
X
X
X
W W W
POC NO.1
TAP,METER, BACKFLOW SIZE: 1.5-INCH
SERVICE LINE SIZE: 1.5-INCH
PEAK DEMAND: 40 GPM
AVAILABLE PRESSURE: X PSI
-OR-
REQUIRED PRESSURE: X PSI
CONTROLLER 'A'
120 VAC POWER REQUIRED
NATIVE SEED AREAS ARE TO
BE IRRIGATED WITH A BELOW
GRADE SYSTEM (TYP).
SHRUB BEDS AND TREES AND
SHRUBS IN NATIVE SEED WILL
BE DRIP IRRIGATED WITH
POINT SOURCE DRIP
EMITTERS (TYP).
SOD AREAS WILL BE IRRIGATED WITH
EITHER SPRAY SPRINKLERS OR
ROTOR SPRINKLERS ON 6" RISERS
USING MATCHED PRECIPITATION RATE
NOZZLES (TYP).
M
A
LOT 2 NATIVE SEED WILL BE
TEMPORARILY IRRIGATED
UNTIL SUCH TIME THAT FULL
BUILD OUT OCCURS.
IRRIGATION POC WILL IRRIGATE BOTH
LOTS 1 & 2 UNTIL LOT 1 NATIVE SEED
IS ESTABLISHED, AT WHICH TIME LOT 1
SYSTEM WILL BE ABANDONED IN
PLACE AND ISOLATION GATE VALVE
SHUT.
PROPOSED
(1)4"&(2)3"
SLEEVES
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER MODEL ICV 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC
REMOTE CONTROL VALVES, GLOBE CONFIGURATION
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL
PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE
AS MAINLINE PIPE.
1.5-INCH REDUCED PRESSURE BACKFLOW PREVENTER
REFER TO DETAILED PLANS
TWO-WIRE IRRIGATION CONTROL SYSTEM
REFER TO DETAIL PLANS
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
REFER TO DETAILS PLANS FOR SIZING
A
IRRIGATION_SCHEDULE
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Pl
o
t
t
e
d
B
y
:
Mi
c
h
e
l
l
e
p
e
t
e
r
s
o
n
La
y
o
u
t
:
IR
M
P
1
.
0
Pr
i
n
t
e
d
O
n
:
12
/
2
0
/
2
0
2
3
9
:
1
4
A
M
Fi
l
e
N
a
m
e
:
MP
-
I
R
-
M
A
S
O
N
S
T
R
E
E
T
I
N
F
R
S
T
.
d
w
g
ORIGINAL SIZE 24X36
ENT
I
T
L
E
M
E
N
T
DRA
W
I
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
T
I
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Klara Rossouw
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
NORTH COLLEGE 1311, LLC
262 E. Mountain Ave.
Fort Collins, CO 80524
p. 970.490.2626
ENGINEER
LAND PLANNER
NORTHERN ENGINEERING
Blaine Mathisen
301 N Howes St, Suite 100
Fort Collins, CO 80521
p. 970.221.4158
OWNER
1 PDP/FDP SUBMITTAL 12/20/23
IRRIGATION MASTER
PLAN
PDP/FDP SUBMITTAL
MASON STREET
INFRASTRUCTURE
TEAM
MLP
R23-008
IRMP1.0
NORTH
0 25 50 100
SCALE: 1"=50'-0"
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com