Loading...
HomeMy WebLinkAboutRIDGEWOOD HILL AMENDMENT TRACT B - MA210028 - SUBMITTAL DOCUMENTS - ROUND 4 - SUPPORTING DOCUMENTATION (3)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 8` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 10` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 12` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 15` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV 17` RADIUS TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER PROS-06-PRS30-CV ADJUSTABLE ARC TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. 30 HUNTER MP CORNER PROS-06-PRS40-CV TURF ROTATOR, 6" (15.24CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. T=TURQUOISE ADJ ARC 45-105. 40 HUNTER MP1000 PROS-06-PRS40-CV TURF ROTATOR, 6" (15.24 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. 40 HUNTER MP2000 PROS-06-PRS40-CV TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. 40 HUNTER MP3000 PROS-06-PRS40-CV TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. 40 HUNTER MP3500 PROS-06-PRS40-CV TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210. 40 HUNTER MP800SR PROS-06-PRS40-CV TURF ROTATOR, 6.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) 40 SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS HUNTER I-20-04-SS 6.0 TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. 45 6 43' T M L O K G R B Y A IRRIGATION_SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-PRB-100-COM MEDIUM PLUS FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. FLOW RANGE 3GPM TO 20GPM. RAIN BIRD MDCFCAP DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING COUPLER. SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G: 1" PLASTIC ELECTRIC REMOTE CONTROL VALVES (SIZE AS DESIGNATED). QUICK COUPLER VALVE ASSEMBLY HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER, RED BRASS AND STAINLESS STEEL, WITH 1" NPT INLET, 1-PIECE BODY. MATCO-NORCA 514TX 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. MASTER VALVE ASSEMBLY BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO MATCH POC WILKINS 375B REDUCED PRESSURE BACKFLOW PREVENTER WITH BLOW OUT/FLUSH FITTING. REINFORCED NYLON HOUSING AND CAST BRONZE BALL VALVES. SIZED TO MATCH TAP & METER (RE: POC NOTE). PEDESTAL MOUNT HUNTER PED-SS-A2C-75D-SS & A2C-WIFI:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INCLUDES A2C WI-FI NETWORKING MODULE FOR ACC2 CONTROLLER. CREATIVE SENSOR TECHNOLOGY FSI-T 1-INCH PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT. FLOW RANGE: .86-52 GPM. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. PLANTING BED DRIP IRRIGATION LATERAL LINE:3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. NATIVE PLANTING DRIP IRRIGATION LATERAL LINE: 3/4-INCH \ BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR SHRUBS PER ADJACENT EMITTER CHART IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED. PIPE SLEEVE: PVC CLASS 200 SDR 21 TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. REFER TO SPECIFICATIONS. A INSTALLATION GENERAL NOTES 1.DESIGN ASSUMES A REQUIRED MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM (NOT OBTAINED) OF 73 PSI, AT A MAXIMUM FLOW OF 18 GPM AT THE 1-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 1.1.IRRIGATION IS CONNECTED DOWNSTREAM OF THE 1-INCH DOMESTIC METER FEEDING THE CLUBHOUSE AS INDICATED. IRRIGATION IS DESIGNED TO UTILIZE ONLY 18 GPM. 1.2.IF PRESSURE IS TESTED LOWER THAN STATED ABOVE, BOOSTER PUMP WILL BE REQUIRED. 2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED, ADDITIONAL SPRINKLERS MAY BE REQUIRED. 9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 14.TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 14.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS 15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. SYMBOL DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE DOMESTIC WATER TAP AND METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT, MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW SHALL BE TESTED UPON INSTALLATION AND ANNUALLY THEREAFTER. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE. IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE SLEEVED. MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN SEPARATE SLEEVES. 1 2 3 4 REFERENCE NOTES SCHEDULE EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. SHEET OF IR1.0 41 NORTH TFG Design, LLC P.O. Box 178 Loveland CO 80539 (970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE FR ON TE RRA G RO UP AND S HALL NO T BE R EPROD UCED, P U B L I S H E D O R U S E D I N A N Y W A Y W I T H O U T T H E P E R M I S S I O N O F T H E L A N D S C A P E A R C H I T E C T . IRRIGATION LEGEND AND NOTES OCTOBER 28, 2022 2ND SUBMITTAL 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill Timm M. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RI D G E W O O D H I L L S FI F T H F I L I N G MI N O R A M E N D M E N T AV O N D A L E R D & T R I A N G L E D R FO R T C O L L I N S , CO L O R A D O LA R I M E R C O U N T Y C O U N T Y 0 15 30 60 MAY 20, 2023 3RD SUBMITTAL SEPT 28, 2023 BASE REVISIONS MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com CONTROLLER 120 VAC POWER REQUIRED 1 A DOMESTIC METER 4 A8 181" A10 161"A12 191" A13 171" A14 181" A15 141" A16 111" A17 171" A18 181" A20 161" A21 151" A22 51" A23 181" A26 181" A28 171" A29 181" A30 181" A31 181" A32 181" A33 181" A35 181"A36 181" A37 171"A38 161" A40 151" A41 141" A42 131" A44 181" A46 161" A47 181" A48 181" A49 171" A52 Drip1" A53 Drip1" A54 Drip1" A55 Drip1" A56 Drip1" A57 Drip1" 2 A5 191" A9 91" A11 181" A19 181" A24 91" A25 171" A27 181" A34 181" A39 171" A43 161" A45 161" A1 151" A2 151" 3 A6 181" 3 3 A7 191" A4 111" A3 131" POC TAP AND METER SIZE: 1-INCH AVAILABLE FLOW: 18 GPM REQUIRED PRESSURE: 73 PSI A50 Drip1" A51 Drip1" A58 111" A59 171" A60 181" A61 101" A62 121" A63 71" A64 181" A65 171" A66 181" A67 181" A68 181" A69 151" A70 151" A71 121" A72 111" A73 151" SHEET OF IR1.1 42 NORTH TFG Design, LLC P.O. Box 178 Loveland CO 80539 (970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE FR ON TE RRA G RO UP AND S HALL NO T BE R EPROD UCED, P U B L I S H E D O R U S E D I N A N Y W A Y W I T H O U T T H E P E R M I S S I O N O F T H E L A N D S C A P E A R C H I T E C T . IRRIGATION PLAN 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill Timm M. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RI D G E W O O D H I L L S FI F T H F I L I N G MI N O R A M E N D M E N T AV O N D A L E R D & T R I A N G L E D R FO R T C O L L I N S , CO L O R A D O LA R I M E R C O U N T Y C O U N T Y 0 15 30 60 OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL SEPT 28, 2023 BASE REVISIONS MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com SHEET OF IR2.1 43 TFG Design, LLC P.O. Box 178 Loveland CO 80539 (970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE FR ON TE RRA G RO UP AND S HALL NO T BE R EPROD UCED, P U B L I S H E D O R U S E D I N A N Y W A Y W I T H O U T T H E P E R M I S S I O N O F T H E L A N D S C A P E A R C H I T E C T . IRRIGATION DETAILS 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill Timm M. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RI D G E W O O D H I L L S FI F T H F I L I N G MI N O R A M E N D M E N T AV O N D A L E R D & T R I A N G L E D R FO R T C O L L I N S , CO L O R A D O LA R I M E R C O U N T Y C O U N T Y OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL SEPT 28, 2023 BASE REVISIONS MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com MASTER VALVE ASSEMBLY2 ISOLATION GATE VALVE ASSEMBLY4 QUICK COUPLING VALVE ASSEMBLY5 REMOTE CONTROL TURF VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY SPRINKLER ASSEMBLY8 FLOW SENSOR ASSEMBLY3BACKFLOW PREVENTION UNIT1 FINISH GRADE/TOP OF MULCH 30-INCH LINEAR LENGTH OF COILED WIRE WATER PROOF CONNECTION (1 OF 2) MASTER VALVE, SIZE TO MATCH POC MODEL PER LEGEND 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL PVC MAINLINE TO SYSTEM BRICK (1 OF 4) PVC SCH 40 MALE ADAPTER (SPEARS SR-2-0801) NON-WOVEN LANDSCAPE FABRIC CHRISTY ID TAG VALVE BOX WITH T-LID. NDS MODEL NUMBER 113BC. BRAND LID WITH VALVE NUMBER FINISH GRADE 10-INCH ROUND VALVE BOX WITH T-LID: NDS MODEL NUMBER 111BC. BRAND LID WITH VALVE "IGV" 4"-8"PVC CL 200 PIPE (PER GATE VALVE SIZE) LENGTH AS REQUIRED. 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL BRICK (1 OF 2) GATE VALVE WITH CROSS HANDLE, SIZED TO MATCH MAINLINE. MODEL PER LEGEND PVC MAINLINE NOTES: 1.NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. PVC SCH. 40 MALE ADAPTER (SPEARS SR-2-0801) 10-INCH ROUND VALVE BOX WITH T-LID: NDS MODEL NUMBER 111BC. BRAND LID WITH VALVE "QC" FINISH GRADE QUICK COUPLING VALVE PER LEGEND STAINLESS STEEL HOSE CLAMP (1 OF 2) 2"x2"x24" REDWOOD STAKE 3-INCH DEPTH OF 3/4-INCH WASHED GRAVEL BRICK (1 OF 2) SCH 80 PVC NIPPLE, TOE (LENGTH VARIES) PRE-FABRICATED SWING JOINT: SPEARS 5805-010-10 PVC MAINLINE PIPE SCH 40 PVC TEE OR EL WITH FPT OUTLET POP-UP SPRAY BODY: WITH CHECK VALVE AND PRESSURE REGULATING VALVE FEATURES SEE LEGEND FOR MODEL FINISH GRADE/TOP OF MULCH SPRAY NOZZLE, PER PLAN: SEE LEGEND FOR MODEL 1/2-INCH MALE NPT x .490 INCH BARB ELBOW: RAIN BIRD MODEL SBE-050 OR APPROVED EQUAL PVC LATERAL PIPE PVC SCH. 40 TEE OR EL SWING PIPE, 12-INCH LENGTH: RAIN BIRD SP-100 OR APPROVED EQUAL NOTES: 1.UTILIZE 40 PSI PRESSURE REGULATING STEM FOR HEADS WITH ROTARY NOZZLES. 2.UTILIZE 30 PSI PRESSURE REGULATING STEM FOR HEADS WITH SPRAY NOZZLES. VALVE DECODER PER CONTROLLER MANUFACTURER. ZIP TIE ONTO 1" PVC PIPE STAKE. CHRISTY ID TAG: BRAND WITH STATION NUMBER REMOTE CONTROL VALVE VALVE BOX WITH COVER: CARSON 1419-4 BRAND LID WITH VALVE NO. (SIZED AS SHOWN ON DRAWINGS) PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL 2-WIRE CONTROL PATH PVC MAINLINE PVC SCH 40 TEE OR EL FOR 2.5" AND SMALLER. DUCTILE IRON FOR 3" AND LARGER BRICK (1 OF 4) PVC SCH 40 EL PVC TRUE UNION BALL VALVE: SIZED SAME AS VALVE FINISH GRADE/TOP OF MULCH WATER PROOF CONNECTION (MULTIPLE) NON-WOVEN LANDSCAPE FABRIC VALVE BOX WITH LOCKING COVER: CARSON 1419 W/ PURPLE LID BRAND "FM" ON LID W/ 3-INCH HIGH LTRS. FINISH GRADE/TOP OF MULCH TWO (2) CONDUCTOR TWISTED PAIR SHIELDED DIRECT BURIAL CABLE FOR CONNECTION TO TRANSMITTER WATER PROOF CONNECTION (1 OF 2) 3M SERIES 7000 EPOXY KIT FLOW METER PER LEGEND PVC MAINLINE BRICK (1 OF 4) 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL NON-WOVEN LANDSCAPE FABRIC MIN. 10 PIPE DIA. STRAIGHT PIPE MIN. 5 PIPE DIA. STRAIGHT PIPE FLOW RAINBIRD SENSOR DECODER: SD210 NOTE: 1.FOR 2-WIRE CONTROL SYSTEMS, DIRECT WIRE MASTER VALVE INTO MV SENSOR PORT. DECODER IS AN OPTIONAL CONNECTION. FINISH GRADE POP-UP ROTOR SPRINKLER: PLASTIC/STEEL RISER (SEE NOTE) AND CHECK VALVE. SEE LEGEND FOR MODEL PRE-FABRICATED SWING JOINT: SPEARS 5805-010-10 PVC SCH 40 TEE OR ELL PVC LATERAL PIPE SCH 80 PVC NIPPLE (1"X3/4"), TOE (LENGTH VARIES) NOTES: 1. INSTALL PLASTIC RISERS FOR ROTORS IN NATIVE AREAS. ALUMINUM ENCLOSURE: STRONGBOX SBBC-30AL OR GUARDSHACK GS-2 REDUCED PRESSURE BACKFLOW PREVENTER PER LEGEND BRASS UNION (1 OF 2) 3/4-INCH MALE ADAPTER WITH PVC CAP TYPE L COPPER (SIZED TO MATCH BACKFLOW) 3-INCH SLEEVE (1 OF 2) FINISH GRADE 6-INCH CONCRETE PAD, 6-INCHES LARGER THAN ENCLOSURE (EACH SIDE) CLASS 200 PVC MAINLINE TO MASTER VALVE SCH 40 PVC COUPLER OR REDUCER COPPER ELL AND NIPPLE NOTES: 1. INSTALL BACKFLOW DEVICE IN ACCORDANCE WITH ALL STATE AND LOCAL CODE REQUIREMENTS. 2. SLOPE TOP SURFACE OF PAD AT 0.5 % WITH BROOM FINISH. MAKE PIPE SLEEVES WITH 1-1/2 INCH LARGER DIAMETER PIPE THAN PENETRATING PIPE SIZE. 3. ALL HINGED CONNECTION LOCATIONS AND HARDWARE TO BE TAMPER PROOF. 4. ALL WELD JOINTS SHALL BE CONTINUOUS AND GROUND SMOOTH. 1 2" COPPER DRAIN COUPLER WITH CAP IN 6" ROUND VALVE BOX. 1 2" COPPER TEE - SIZED PER SERVICE LINE SHEET OF IR2.2 44 TFG Design, LLC P.O. Box 178 Loveland CO 80539 (970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE FR ON TE RRA G RO UP AND S HALL NO T BE R EPROD UCED, P U B L I S H E D O R U S E D I N A N Y W A Y W I T H O U T T H E P E R M I S S I O N O F T H E L A N D S C A P E A R C H I T E C T . IRRIGATION DETAILS 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill Timm M. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RI D G E W O O D H I L L S FI F T H F I L I N G MI N O R A M E N D M E N T AV O N D A L E R D & T R I A N G L E D R FO R T C O L L I N S , CO L O R A D O LA R I M E R C O U N T Y C O U N T Y OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL SEPT 28, 2023 BASE REVISIONS MPi Designs PO BOX 369 ● AULT, CO ● 80610 970-402-3047 Michelle@MPiDesignsllc.com 24" 4" 4" 4" 18" 4"24" 4" 4" MAINLINE, LATERAL, & 24-V WIRE LATERAL PIPE FIN. GRD. PIPE AND WIRE SLEEVING CONC. SLAB EXCAVATED MATERIAL BEDDING & COVER MATERIAL NOTES: 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. "SNAKE" UNSLEEVED PLASTIC PIPE IN TRENCH. PROVIDE A MINIMUM OF 2" CLEARANCE TO SIDE OF TRENCH AND BETWEEN PIPES. 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP AT ALL CHANGES OF DIRECTION OVER 30 DEGREES. WIRING SLEEVE PIPE SLEEVE REMOTE CONTROL DRIP VALVE ASSEMBLY17 SINGLE OUTLET EMITTER ASSEMBLY18 TYPICAL TRENCHING DETAIL15 DRIP FLUSH CAP ASSEMBLY20 NOTE: 1) ALL SLEEVING TO B E CLASS 200 BE PVC, SIZED AS NOTED. 2) INSATLL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPPLE SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO NOT STACK SLEEVES VERTICALLY. 2" PVC PIPE SLEEVE MARKER - INSTALL AT BOTH ENDS OF EACH SLEEVE LOCATION AND EXTEND AT LEAST 3' ABOVE GRADE. SPRAY EXPOSED PORTION OF MARKER WITH GREEN FLUORESCENT PAINT. PVC SLEEVING (TYPICAL) PAVED SURFACE TYPICAL SLEEVING DETAIL14 CURB AND GUTTER IF APPLICABLE ROUGH GRADE SEAL ENDS OF SLEEVES WITH CLOTH DUCT TAPE (TYPICAL) 24" min. 12" min 4"-6" MIN. 4"-6" MIN. 36" INLINE DRIP PIPE ASSEMBLY FOR TREES IN NATIVE 19 PEDESTAL MOUNT CONTROLLER ASSEMBLY16 DIFFUSER BUG CAP: RAIN BIRD MODEL DBC-025 1/4-INCH TUBING STAKE: RAIN BIRD #TS-025 1/4-INCH DISTRIBUTION TUBING MULCH BED FINSH GRADE DRIP LATERAL PIPE DRIP EMITTER (REFER TO SPECIFICATIONS) NETAFIM TECHLINE CV INLINE DRIP TUBING: MODEL TLCV6-18 TIE DOWN STAKE, (QTY. AS REQUIRED) TREE TRUNK NOTE: 1.CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN NATIVE AREAS 2-3" BELOW GRADE IF MULCH IS NOT PRESENT. IF MULCH IS PRESENT, LAY TUBING ON FINISHED GRADE BELOW MULCH. 2.DIAMETER OF DRIPLINE RINGS ARE DEPENDENT ON TREE CANOPY SIZE AND SHALL BE ADJUSTED IN THE FIELD PER CONTRACTOR. SUGGESTED PLACEMENT OF 2' DIAMETER AND 3' DIAMETER AROUND TREE. 3.SHRUBS IN NATIVE SHALL UTILIZE SINGLE OUTLET EMITTERS. TEE FITTING INSERT AND PVC THREADED 1-INCH CLASS 200 PVC SDR 21 PIPE INSERT ELBOW FITTINGS WITH STAINLESS STEEL SCREW CLAMPS FLUSH CAP (1 of 2) FINISH GRADE/TOP OF MULCH FLUSH CAP: AGRIFIM MODEL CETC-34 3/4-INCH COMPRESSION FIT CROSS- THREADED CAP DRIP TUBING LOOP 3-INCH DEPTH OF 3/4-INCH WASHED GRAVEL BRICK (1 OF 2) 3/4-INCH DRIP LATERAL PIPE 3/4-INCH COMPRESSION EL NOTE: 1.LOOP IRRIGATION DRIP TUBING INSIDE VALVE BOX FOR EXTENSION OUTSIDE OF BOX DURING BLOWOUT. 6-INCH ROUND VALVE BOX WITH T-LID: NDS MODEL NUMBER 107BC. TYPICAL GROUNDING (AT VALVE) ASSEMBLY13 GROUND WIRE OF DECODER CONNECTED TO GROUND ROD USING BRASS CLAMP 2-WIRE COMMUNICATION PATH BLUE WIRES TO 2-WIRE COMMUNICATION PATH FINISH GRADE SURGE ARRESTOR: PER CONTROLLER MANUFACTURER DBY CONNECTORS WHITE WIRES TO SOLENOID VALVE BOX DECODER: PER CONTROLLER MANUFACTURER CHRISTY ID TAG: MARK WITH STATION NO. EXPANSION COILS BRASS CLAMP SOLENOID VALVE BOX EXTENSION (LENGTH AS REQUIRED) 3/4" WASHED GRAVEL NOTES: WIRES MUST EXTEND 12" ABOVE VALVE BOX FOR SERVICE. 5/8" DIA. X 8'-0" COPPER CLAD GROUND ROD, DRIVEN INTO GROUND WITH TOP OF ROD MINIMUM OF 6" BELOW GRADE. 50 OHMS OR LESS (HUNTER). SEE HUNTER SPECIFICATIONS FOR COMPLETE GROUNDING INFORMATION. FINISH GRADE/TOP OF MULCH SPEARS PVC TRUE UNION BALL VALVE PVC SCH 40 EL (1 OF 2) APPROVED GEOTECH FILTER FABRIC (EXTEND 10" UP BOX WALL) BRICK (1 OF 4) PVC SCH 80 PIPE (LENGTH AS REQUIRED) PVC MAINLINE LOOP 1' OF 2 SPARE WIRES IN VALVE BOX PVC SCH 40 TEE OR EL 3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL COMBINED PRESSURE REGULATOR AND Y-STRAINER NOTE: 1.USE BARBED INSERT FITTINGS ON DRIP LATERAL PIPE WITH HOSE CLAMPS. PLACE CLAMPS ON DRIP TUBING DIRECTLY OVER BARBED AREA OF FITTING. PINCH CLAMPS ARE NOT ACCEPTABLE. 2.KEEP MINIMUM OF 3" FROM TOP OF SOLENOID TO VALVE BOX LID. 30-INCH LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION (1 OF 2) CHRISTY ID TAG VALVE BOX WITH COVER: CARSON 1419-4 BRAND LID WITH VALVE NUMBER REMOTE CONTROL VALVE. (SIZED AS SHOWN ON DRAWINGS) VALVE DECODER PER CONTROLLER MANUFACTURER 24" X 18" X 18" CONCRETE FOOTING FOR PEDESTAL ASSEMBLY, ROUTE 120V AC ELECTRICAL POWER, COMMON AND CONTROL WIRES THROUGH CONDUIT AS SHOWN LABEL CONTROLLER WITH 4" HIGH VINYL LETTERING. (LABEL PER PLAN) PEDESTAL MOUNT CONTROLLER: SEE LEGEND FOR MODEL 120 VOLT, 15 AMP 3-PRONG RECEPTACLE 3' COIL OF ALL SPARE WIRES STORED WITHIN PEDESTAL, USE WIRE TIES TO SECURE COILS FINISH GRADE CONTROL WIRES TO ELECTRICAL VALVES #6 BARE COPPER GROUNDING WIRE TO BRONZE CLAMP COPPER CLAD GROUNDING ROD (5/8" X 8') PAIGE ELECTRIC PART NUMBER 182007. MINIMUM 10 FT. PVC SWEEP ELL 1.5" SIZE WIRELESS RAIN SENSOR: WIRELESS RAIN-CLIK SET ADJUSTMENT TO 1/8TH INCH. MOUNT SECURELY TO ADJACENT BUILDING OR POLE MOUNT. NO DONE INSTALL IN SOD AREA. NOTES: 1. INSTALL RAIN SENSOR ON TREATED 4X4 POST IF CONTROLLER IS IN TURF AREA. POST TO BE MOUNTED IN SHRUB BED TO AVOID BEING IRRIGATED BY OVERHEAD SPRINKLERS. A