HomeMy WebLinkAboutEAST MULBERRY PLACE - 38-87 - SUBMITTAL DOCUMENTS - ROUND 1 - PROJECT NARRATIVEa., TITLE:
REQUEST:
EAST MULBERRY PLACE
Approval to develope 6.43 acres of commercial uses
adjacent to 4.24 acres of residential use.
LOCATION: NWl/4,NE1/4, 17-7-68; located on the southwest
corner of the intersection of the Highway 14
frontage road and County Road 9E.
APPLICANT: Richard Leisy
STAFF CONTACT: Al Kadera FILE NO. S-68-87
I. . SITE DATA
Designer:. John Dengler & Associates, P.C.
Total Development Area: 10 acres +-
Number of Lots: 32 lots; 4 commercial/28 residential
Proposed Density: 6.6 du/acre
Number of Dwelling Units: 28 residential
Existing Land Use: vacant
Proposed Land Use: commercial/residential
Land Use Designation: Fort Collins UGA
Services:
Access: Highway 14 Frontage Road
Water: ELCO
Sewer: Boxelder
Fire Protection: Poudre Fire Authority; one mile
Exisiting zoning: C-CommerciaL.M-Multiple Family
No. Trips Generated by Use To be determined
II. Project Description and Site Analysis
to station no. 6
The applicant is proposing to develope 6. 43 . acres of property for
commercial uses and 4.24 acres of, single family residential units (28
units) immediately to the south of the commercial property. The
commercial property will consist of four lots. Lot sizes. will be 1.1
(convenience store) , 1.0 (resteraunt) , 2.2 (60 unit motel and parking)
and 1.4 (storage lot) acres each. The residential portion of the
development will consist of 28 single family dwelling units on lots with
-2-
a minimum lot size of 3500 square feet. Access to the site will be from
the frontage road and Countryside Drive located in Countryside Park.
The site is bordered on the east by a New Cache La Poudre Irrigation Co.
ditch.
The property is currently vegetated in pasture grass and weeds. The
property has very little slope and drainage is poor. The east portion
of the property is very wet and appears to have no drainage.
III. Compatibil ity:
To the north of the site exists mostly commercial use.s . To the east of
the site is some commercial uses as well. as single family residential
developments. Pleasant. Acres is located on the east side with 116 lots
ave-raging .43 aces each. Boxelder Estates is located south of Pleasant
Acres with 54 lots averaging 1.29 acres each. South and southeast of
the site is Countryside Park which has 263 lots averaging .16 acres
each. West of the property are redominantly commercial uses
IV. Staff Comments
1. Zoning Comments: The southern portion of the site is zoned M not
M-1 as shown on the plat. The minimum area for a PUD in the M-Multi.ple
Family Zone is five acres. A variance will be required for a project
hav ing a smaller area. This variance is submitted with the master plan
and will be considered by the Planning Commission and the Board of
County Commissioners. Open storage is not a permitted use in the
C-Commercia.l Zoning District. We may be able to consider the proposed
storage area if the applicant can demonstrate by building elevations and
landscaping, that the storage will not adversely affect the existing or
proposed residential areas.
2. See the attached information from the County Engineer and the State
Highway Department concerning access to this site and requirements for
the construction of internal roads.
3. This site is within the Urban Growth Area for the City of Ft.
Collins therefore all the application criteria apply. There are
specific landscaping regvi.rements for commercial uses which are usually
imposed at building permit. This site has a significant amount of
frontage on Highway 14. All the frontage should be landscaped by the
applicant under a subdivision improvements agreement. This procedure
-3 -
will assure that a consistent de.sign will be provided for the entire
frontage.
c. There are several easement requests that affect the residential
area.Poudr.e Valley REA requests 15-foot easements along, all streets and
roadways in addition to 1.5-foot easements along all property lines.
Mountain Bell requests a 10-foot perimeter easement in the Commercial
area and 6-foot rear lot easements in the residential area. They will
also accept blanket easements. Public service requests 8-foot easements
along all streets and cul-de-sacs on both sides. There may be some
conflicts among the various utility providers making it impossible for
them to share easements. It appears that once the easments are placed
on this plat there is very little room left outside the pooposed
building envelopes . The applicant should work very closely with the
utilities to make sure all their needs are addressed before a
preliminary phase plan is submitted.
5. Since. Countryside Drive is to provide at least a secondary access to
this site the developer should contact the homeowners association about
joining their efforts at road maintenance. The County. Commissioners
will require that this site pay its fair share toward maintaining
Countyyside Drive.
6. There is signi.f.icant concern about the ground water levels in this
area. Core samples were taken a few years ago on the streets in
Countryside Park and the ground immediately below the road base was very
wet. The geology report submitted with the master plan must
specifically address the affect of the ground water on the proposed
development.
7'. There may be a conflict between the proposed truck parking area and
the residential area. When truckers get ready to depart they start
their trucks and let them idle for some time. If this occurs early in
the morning there could be some angry residents in the area. The
applicant should demonstrate that these conflicts can be mitigated by
berming .and landscaping or other techniques.
8. The building envelopes in the residential area should be drawn with
particular attention to building code requirements concerning minimum
separation between single family dwellings and accessory buildings.
Attached garages must have. fire walls between them. Detached single
family dwellings must have at least ten feet between them exclusive of
overhangs or eaves.
9. Larimer County Park Fees for the Ft. Collins Urban Growth Area will
apply to this project. A note should appear on all plats concerning the
payment. of park fees when building permits are issued. I.n addition to
the residential area, park fees will also apply to the motel.
10. The landscaping plan for the site should also include all the
proposed signs for the commercial and residential uses. Sign sizes and
locations should be included.
11. The Planned Unit Cevelopment Resolution requires a .minimum
perimeter setback of 20 feet. It appears that some of the porposed
-4-
units may not meet this requirement.
12. The application is not absolutely clear on the purpose of the
cross -over easements. What are they and why are they there?
13. The PUD Resolution requires a minimum of 30% of the developable
area in open space in residential areas. The application does not give
open space calcualtions but it appears that this requirement has not
been met.
14. Commercial PUD's are governed by a ratio of building to lot square
footage. The C-Commercial Zone allows a ratio of 1 unit of building for
each 2.5 units of lot_ There does not appear to be a problem in this
regard but the. calculations should be provided with the master plan
application.
1.5. The Health Department indicates that written commitments for water