HomeMy WebLinkAboutUNION PARK - PDP230005 - SUBMITTAL DOCUMENTS - ROUND 3 - DRAINAGE REPORT PRELIMINARY DRAINAGE REPORT FOR Union Park Prepared by: Highland Development Services 6355 Fairgrounds Ave, Suite 100 Windsor, Colorado 80550 Phone: 970.674.7550 Prepared for: Landmark Real Estate Holdings, LLC 6341 Fairgrounds Ave, Suite 100 Windsor, Colorado 80550 Office: 970.460.0567 December 6, 2023 Job Number 21-1044-00 6355 FAIRGROUNDS AVE, SUITE 100, WINDSOR, COLORADO 80550 | PHONE 970.674.7550 December 6, 2023 Mr. Wes Lamarque Fort Collins Utilities 700 Wood Street Fort Collins, CO 80522 RE: Preliminary Drainage Report – Union Park (Previously Ziegler-Corbett) Dear Wes, We are pleased to submit, for your review, the Preliminary Drainage Report for the Union Park (Ziegler – Corbett) Preliminary Development Plan. This report describes the general drainage design intent to be implemented with future development and in accordance with the criteria in the City of Fort Collins Storm Drainage Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, Highland Development Services Jason T. Claeys, P.E., LEED AP Page i TABLE OF CONTENTS Table of Contents ............................................................................................................................. i Engineer’s Certification Block ..........................................................................................................ii General Description and Location .................................................................................................. 1 Site Description and Location ...................................................................................................... 1 Site Soils ....................................................................................................................................... 1 Storm Drainage Criteria .................................................................................................................. 3 Existing Conditions ...................................................................................................................... 3 Hydrologic Criteria ....................................................................................................................... 4 Hydraulic Criteria ......................................................................................................................... 4 Drainage Basins ............................................................................................................................... 6 Drainage Facility Design .................................................................................................................. 7 Drainage Conveyance Design ...................................................................................................... 7 Detention/Water Quality Pond Design ....................................................................................... 7 Detention/Water Quality Pond Variance Request ...................................................................... 8 Low Impact Development ............................................................................................................... 9 Stormwater Pollution Prevention ................................................................................................. 11 Conclusions ................................................................................................................................... 12 References .................................................................................................................................... 13 Appendix ....................................................................................................................................... 14 Appendix A – Site Vicinity Map & References ............................................................................. A Appendix B – Rational Calculations ............................................................................................. B Appendix C – Detention Pond Calculations ................................................................................. C Appendix D – Street Capacity Calculations ................................................................................. D Appendix E – Low Impact Development Calculations ................................................................. E Page ii ENGINEER’S CERTIFICATION BLOCK I hereby certify that this Preliminary Drainage Report for Union Park was prepared by me (or under my direct supervision) for the owners thereof and meets or exceeds the criteria of the City of Fort Collins Stormwater Design Standards. ________________________________________ Jason T. Claeys, PE Registered Professional Engineer State of Colorado No. 42122 Page 1 GENERAL DESCRIPTION AND LOCATION SITE DESCRIPTION AND LOCATION The Union Park property is located in the Southeast Quarter of Section32, Township 7 North, Range 68 West of the Sixth Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. More specifically, the Union Park property is located north of the Front Range Village commercial area, east of the Affinity residences, south of the English Ranch residential subdivision, and west of Ziegler Road. The project site is approximately 32.78 acres currently and is undeveloped agricultural and rural residential land, with one residence and multiple outbuildings. The site appears to be mostly vegetated with grass harvested for livestock feed. The site generally slopes from the west to the east at about 0.7% slope. The intent of the Preliminary Development Plan (PDP) is to update the ODP with the anticipated uses. No improvements are being constructed with the PDP, but rather establishing future expectations for development. The property is anticipated to be a high-density multi-use development, mainly multi-family residential, with retail space and supporting amenities. The Union Park property is located within the City’s Fox Meadows Drainage Basin. In addition to the City of Fort Collins Stormwater Design Standards, drainage requirements are also described in both the “Front Range Village Final Drainage and Erosion Control Study,” prepared by Stantec Consulting Inc., dated February 2007, and the “Final Drainage Report for Affinity Fort Collins,” prepared by JR Engineering, LLC, dated March 2, 2016. No City or FEMA floodplains/floodways are located within the Union Park property. SITE SOILS The Union Park project site consists primarily of Nunn clay loam (0 to 1 percent slopes) that is classified as Type-C hydrologic group. According to USDA/Natural Resource Conservation “Group, Type C soils have a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission.” Page 2 Per the “Preliminary Geotechnical Subsurface Exploration Report, Proposed Ziegler-Corbett Mixed-Use Development”, prepared by Soilogic, Inc., dated April 4, 2022: “approximately 4 to 6 inches of vegetation and topsoil was encountered at the surface at the boring locations, underlain by brown/beige/rust lean clay with varying amounts of sand which varied to clayey sand in places. The apparently-natural lean clay/clayey sand varied from soft to hard in terms of consistency or from very loose to medium dense in terms of relative density, typically exhibited no to low swell potential at in-situ moisture and density conditions (however one sample of sandy lean clay obtained from boring B-2 at a depth of about 9 feet below ground surface exhibited moderate swell potential) and extended to the bottom of each of the borings at a depth of approximately 15feet below present site grades.” “Groundwater was observed during the subsurface soil exploration: “Groundwater was not encountered in borings B-1, B-2, B-3 or B-5 to the depths explored (about 15 feet below ground surface), but was measured at a depth of about 15 feet below ground surface in boring B-4 when checked immediately after completion of drilling. When checked about five (5) days after drilling, borings B-1, B-2 and B-5 remained dry to the approximate depth explored, while groundwater was measured at a depth of about 14 feet below ground surface at the locations of borings B-3 and B-4 at that time. Groundwater information is indicated in the upper right- hand corner of the attached boring logs.” “Groundwater levels will vary seasonally and over time based on weather conditions, site development, irrigation practices and other hydrologic conditions. Perched and/or trapped groundwater conditions may also be encountered at times throughout the year. Perched water is commonly encountered in soils overlying less permeable soil layers and/or bedrock. Trapped water is typically encountered within more permeable zones of layered soil and bedrock systems. The location and amount of perched/trapped water can also vary over time.” Page 3 STORM DRAINAGE CRITERIA This Preliminary Drainage Report was prepared to establish drainage basins, and required detention volumes, that meet or exceed the City of Fort Collins storm water criteria. The City of Fort Collin’s Storm Drainage Design Criteria and amendments to the Urban Drainage Flood Control District’s (UDFCD) Drainage Criteria Manual (USDCM) Volumes 1, 2 and 3 were referenced as guidelines for this design. EXISTING CONDITIONS The Union Park Property is a portion of a drainage basin that is situated north of Harmony Road, and west of Ziegler Road, which runoff is conveyed east under Ziegler Road into the existing drainage channel on the HP Harmony Campus property. It has been determined in the Front Range Village Final Drainage Report that this area is allowed to contribute 76.7 cfs to the HP Campus drainage channel during 100-year event peak discharge. More specifically to this site, 20.1 cfs release rate was allocated to the Union Park & the Affinity Fort Collins properties. Per The Final Drainage Report for Affinity Fort Collins, the Affinity site has a 100-yr peak release rate of 2.1 cfs, allowing a 100-yr peak discharge of 18.0 cfs from the Union Park property. The Harmony Village Manufactured Home Community does not provide adequate detention facilities. During a 100-yr storm event, a portion of the site flows to the east into both the Front Range Village development as well as the Affinity Fort Collins site. This runoff was evaluated in the Front Range Village Final Drainage Report and was determined to be 116 cfs peak runoff during the 100-yr event. This runoff will be collected in the Front Range Village Detention Pond D, intended to collect but not detain his flow. During the 100-year event, this peak flow of 116 cfs will flow over the weir on the north side of Detention Pond D. It is conveyed via the private drive aisles to a level spreading weir on the northeast side of the Affinity Fort Collins site, where it is discharged into the Union Park property. This flow is then assumed to sheet flow east to be inadvertently detained on the east side of the Union Park property along Ziegler Road. In reference to the Front Range Village Final Drainage Report, a detention pond is planned to be incorporated into the Union Park site, Detention Pond 298. The volume of Detention Pond 298 has been determined by detaining the 100-yr peak developed runoff to the 2-yr historic runoff rate, adding the existing inadvertent detention volume (detention volume is currently provided onsite due to existing constraints such as grade features and outlet restrictions). Based on the topographic survey of the existing conditions, the inadvertent detention volume is constrained for this site by the spill location along the north property line, at an approximate elevation of 4928.0 ft. The inadvertent detention volume is estimated to be 7.5± acre-ft. The Page 4 estimated volume did not account for the two existing culverts along the west side of Ziegler Road that currently provide ponding relief for the Ziegler-Corbet site. All supporting preliminary calculations are located in the Appendix. HYDROLOGIC CRITERIA The rational method was performed to calculate the peak runoff rates for each basin. Percent impervious were estimated based on land use, and the associated runoff coefficients were calculated. The time of concentration was calculated using the City of Fort Collins’s initial time of concentration, and the intensity was calculated using the corresponding storm rainfall depth and USDCM Equation 4-3. To account for the City of Fort Collins’ IDF Curve, Coefficient 3 of the UDFCD’s intensity formula was adjusted to 0.7867. The City of Fort Collins area has a 2-yr 1-hr rainfall depth of 0.82 inches and a 100-yr 1-hr rainfall depth of 2.86 inches. These depths account for the 1999 adjusted rainfall depths. HYDRAULIC CRITERIA The hydraulic calculations provided in this report are limited to maximum street capacities based on the minimum street slopes (0.5%) for the most restrictive sections. The final Union Park storm drainage system will be designed to convey the minor and major storm events through the combination of streets, inlets, storm sewer pipes, and swales. Per the requirements provided by the City of Fort Collins Storm Drainage Design Criteria, all inlets and storm pipes will be designed such that, during the minor initial storm event, the 2-yr storm, the flows for the streets will not top the curb and may only rise to the street crown elevation, and for the entrance (with Median) will not top the curb and the flow spread will leave at least one 12 ft lane width free of water in each direction. During the major storm event, the 100-yr storm, the water depth for the streets will be held to a maximum depth of 6” at the street crown, 12” at the gutter flow line, and/or flow must be contained within right-of-way or easements paralleling the right-of-way. Within the Final Drainage Report, peak basin runoff flows from the rational calculations will then be used to determine the street flows, and on-grade inlet locations. The on-grade and sump inlet capacities will be calculated using UDFCD’s spreadsheet UD-Inlet_v4.05.xlsm. The inlet capacities will be analyzed, and the necessary adjustments will be applied to the street runoff flows based on the amount of runoff collected by on-grade inlets. The sump inlets will be sized using the previously mentioned street capacity allowances, with overtopping if needed. Page 5 The captured flows will then be analyzed using EPA’s SWMM program to design pipe size and slopes. UD-Inlet applies a clogging factor while sizing the inlets, but while sizing the storm pipes, it is assumed that the inlets are free of clogging debris and capture the maximum amount of street runoff. Orifice rating curves will be utilized for the inlet capture capacities and route the captured runoff through the storm drain system. The program accounts for head losses within manholes and bends and head losses associated with pipe friction. The previous drainage study SWMM models have been provided by the City of Fort Collins. These models will be reviewed during the final drainage design to develop and inflow hydrograph from the offsite basins and safely conveyed through the project. Hydraflow will be used to compute the open channel hydraulics and check the capacities of the drainage swales throughout the site. Flow velocities within these swales will be reviewed and where flows are found to be supercritical, the swales will be protected with turf reinforcement mat. All swale and pipe outlets will be protected with riprap or suitable erosion protection methods. Storm sewer pipe outlets will be protected using the requirements set by the USDCM to protect downstream of culverts. All supporting calculations for street sections are located in the Appendix. Page 6 DRAINAGE BASINS The Union Park developed drainage basins are delineated by areas draining to major drainage elements. The Union Park property is divided into four developed drainage basins. The final drainage report will further detail the drainage basins. For the purpose of this Preliminary Drainage study impervious areas have been calculated and applied. Drainage Basin D1 consists entirely of pond 298A, having an area of 2.69 acres. This basin will convey detained flows to pond 298C in a system of pipes, with overflow being routed through streets to pond 298C and ultimately offsite. No water quality will be provided for this basin. Drainage Basin D2 consists of 9.10 acres of single-family attached and apartment residential lots, attached garages, streets, private drives, and the club house recreation area. Flows from this basin are mainly conveyed along roadways and collected by inlets and conveyed to detention Pond 298B. Low Impact Development (LID) will be used to address water quality in this basin through the application of ADS Stormtech MC-3500 Filtration Chambers. Drainage Basin D3 consists of 4.92 acres of attached single-family residential lots, attached garages, streets, and private drives. Flows from this basin are mainly conveyed along streets and will be collected by inlets and ultimately conveyed to detention Pond 298C. LID will be used to address water quality in this basin through the application of ADS Stormtech MC-3500 Filtration Chambers. Drainage Basin D4 consists of 6.91 acres of attached single-family and apartment residential lots, commercial and mixed-use lots, attached garages, streets, and private drives. Flows from this basin are mainly conveyed along streets and will be collected by inlets and conveyed to detention Pond 298C. LID will be used to address water quality in this basin through the application of ADS Stormtech MC-3500 Filtration Chambers. Pond 298B is within this basin and will provide additional detention during major events prior to discharging via storm drains to Pond 298C. Drainage Basin D5 consists of 8.43 acres of attached single-family and apartment residential lots, commercial and mixed-use lots, attached garages, streets, and private drives. Flows from this basin are mainly conveyed along streets and will be collected by inlets and conveyed to detention Pond 298C (located within this basin). Standard water quality will be used to address water quality in this basin with the inclusion of extended detention for the WQCV. Page 7 DRAINAGE FACILITY DESIGN DRAINAGE CONVEYANCE DESIGN Storm infrastructure to convey runoff will include concrete trickle pans, inlets, storm sewer and culverts. Stormwater detention and water quality enhancement will be achieved using extended detention and low impact development (LID). Storm inlets, storm sewers and the roadway culverts will be appropriately sized with the final drainage design. DETENTION/WATER QUALITY POND DESIGN The FAA Method was utilized to estimate the required detention to be 7.7± acre-ft for the developed conditions in accordance with the City of Fort Collins requirements (the 100-year developed peak runoff detained to the 2-year historical peak runoff). Combining the inadvertent detention (7.5 ac-ft), the standard Water Quality Capture Volume (WQCV) for drainage basin D4 (0.20 ac-ft) and the detention volume (7.7 ac-ft), a total of 15.4± ac-ft is required to accommodate the developed site, as well as account for the displacement of the historical inadvertent detention. Due to the limited grades on the site, and the profusion of detention volume, multiple ponds are planned, with the main detention pond located in the northwest corner of the site (298A), a smaller pond to provide additional detention during major events located near the middle of the site (298B), and the detention pond (298C) located adjacent to the eastern property line. Pond 298A outlet connects to an underground storm drain leading to pond 298B. Overflow from pond 298A will flow via a spillway and streets to pond 298C. The outlet for pond 298C will connect to an existing 30-inch storm drain that conveys stormwater east under Ziegler Road. The ultimate outfall will be the existing HP Harmony Campus storm channel system, which ultimately flows into the Cache La Poudre River. EPA SWWM will be utilized for the final drainage design. As mentioned, the detention volume described above is designed to be provided in two on-site detention facilities: Pond 298A detention basin (DB) will be used as site detention and account for the displacement of the historical inadvertent detention. The DB will provide an estimated detention volume of 11.7 ac-ft. The outlet will be sized to overdetain the offsite flows to maximize the pond volume. Pond 298B detention basin (DB) will be used to provide additional site detention in major storm events. The outlet, which is also the inlet for the LID facility, will be Page 8 designed to surcharge during major storm events and provide approximate 0.42 acre-ft of detention storage. Pond 298C extended detention basin (EDB) with a dry bottom will be utilized as site detention and standard water quality (SWQ) facility for basin D4. The EDB will provide an estimated detention volume of 4.2 acre-ft, in addition to ponds 298A and 298B, as required to accommodate the site in its developed condition. UDFCD is referenced for the water quality capture volume (WQCV) of 0.21 ac-ft with a 40-hr drain time. Pond 298C will release to an existing 30” storm drain under Ziegler Road leading to the HP Harmony Campus storm channel. Pond 298A has an estimated storage volume of 11.7± ac-ft, Pond 298B has 0.42± ac-ft, and pond 298C has 4.2± ac-ft. The combined detention volume from Ponds 298A, 298B & 298C is 16.3± ac-ft and exceeds the estimated required detention volume of 15.4± acre-ft. The final design will ensure the pond overflows, and outlet structures are designed to release flows as outlined above in accordance with the City of Fort Collins requirements. Reference the appendix for estimated calculations and the drainage plan. DETENTION/WATER QUALITY POND VARIANCE REQUEST The Union Park site has several challenges that have limited the ability to meet the requirement in Chapter 8, Section 3.1 Geometry of Stormwater Detention Facilities for the site’s various detention ponds embankments and side slopes to “vary and undulate.” The site is flat with very limited geographical relief (0.7% avg slope). Additionally, the site must account for inadvertent detention that more than doubles the detention storage volume required. Accommodating for the flat site and the large volume of detention, the ponds had to be maximized for volume. In order to maximize the ponds for volume, some pond side slopes are augmented with stepped landscape walls and 4:1 slopes. We request a variance to the requirement to “vary and undulate” the site’s detention ponds embankments and side slopes to maximize detention pond volumes. This variance will not be detrimental to public health, welfare, and safety, and will have no impact on the capital and maintenance costs of the City of Fort Collins. It is respectfully requested that this variance be granted. Page 9 LOW IMPACT DEVELOPMENT The City of Fort Collins updated the Low Impact Development ordinance in 2016 (Ordinance No. 007, 2016) to require: • Treat at least 75% of any newly developed or redeveloped impervious area using one or a combination of LID techniques, or • Treat at least 50% of any newly developed or redeveloped impervious area using one or a combination of LID techniques when 25% of private drivable surfaces are permeable. To satisfy the required implementation of Low Impact Development (LID), the Union Park property will utilize below-grade filtration galleries (ADS StormTech chamber system model MC-3500). Other LID techniques were explored, but due to the limited grade available and the amount of detention volume required, shallow filtration galleries assisted in maintaining storm drain grades and detention volumes. Pavers within the private drives did not treat enough contributing areas to justify their use. Filtration galleries will promote filtration while capturing fine sediment that drains off the impervious areas. Isolator rows will be implemented at the headworks to the filtration galleries to allow larger sediment particles to settle before entering the gallery. The isolator rows will be accessible to remove sediments. A Standard Operations Procedure will be provided at the final design to ensure these BMPs adequately perform over time. For this preliminary design, the impervious area was calculated in each drainage basin. Basins D2, D3, and D4 will be treated utilizing filtration chambers (LID), resulting in 73.3% of the developed impervious area being treated using LID best practices. The remaining impervious area within basin D5 will be treated using an extended dry detention pond (pond 298C) with a 40-hour drain time of the WQCV. The water quality treatment provided by LID practices is slightly below the required 75% impervious area treatment. Consideration of the disconnected impervious areas, roof and walks that drain to landscape areas prior to being directed to storm drains, is requested as additional treatments. Below is a description of the 4-step process for selecting structural BMPs: Urban Drainage and Flood Control District (UDFCD) recommends a Four Step Process for receiving water protection that focuses on reducing runoff volumes, treating the water quality capture volume (WQCV), stabilizing drainage ways, and implementing long-term source controls. The Four Step Process applies to manage more minor, frequently occurring events. Page 10 Step 1: Employ Runoff Reduction Practices To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement Low Impact Development (LID) strategies, including Minimizing Directly Connected Impervious Areas (MDCIA). Captured runoff from strategic areas are routed through below grade filtration galleries, bioretention pond/rain gardens, and/or permeable pavers. Filtration galleries, rain gardens, and permeable pavers will slow runoff, promote filtration, and filter runoff prior to being released into the adjacent storm drain system. Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow Release The infiltration galleries, rain gardens, and permeable pavers are designed to provide water quality capture volume per Urban Drainage’s recommendations and calculations. The captured runoff is design for a 12-hr drain time. Step 3: Stabilize Drainageways Natural Drainageways are subject to bed and bank erosion due to increases in frequency, duration, rate, and volume of runoff during and following development. Because the site will drain to an existing storm system, bank stabilization is unnecessary with this project. Step 4: Implement Site Specific and Other Source Control BMPs Proactively controlling pollutants at their source by preventing pollution rather than removing contaminants once they have entered the stormwater system or receiving waters is important when protecting storm systems and receiving waters. This can be accomplished through site- specific needs such as construction site runoff control, post-construction runoff control, and pollution prevention / good housekeeping. It will be the contractor’s responsibility to develop a procedural best management practice for the site. Page 11 STORMWATER POLLUTION PREVENTION Erosion and sedimentation can be controlled on-site by use of sediment control logs, inlet protection, a gravel construction entrance, seeding, mulch, and turf. The measures are designed to limit the overall sediment yield increase due to construction as required by the City of Fort Collins. During overlot and final grading the soil will be roughened and furrowed perpendicular to the prevailing winds. During the performance of the work required by these specifications or any operations appurtenant thereto, whether on right-of-way provided by the City or elsewhere, the contractor shall furnish all labor, equipment, materials, and means required. The Contractor shall conduct proper efficient measures wherever and as necessary to reduce dust nuisance, and to prevent dust nuisance that has originated from his operations from damaging crops, orchards, cultivated fields, and dwellings or causing a nuisance to persons. The Contractor will be held liable for any damage from dust originating from his operations under these specifications on a right-of-way or elsewhere. It is unlawful to track or cause to be tracked mud or other debris onto city streets or rights-of- way. Wherever construction vehicles access routes or intersect paved public roads, provisions must be made to minimize sediment transport by runoff or vehicles tracking onto the paved surface. Stabilized construction entrances are required with base material consisting of 6” coarse aggregate. The contractor will be responsible for clearing mud tracked onto city streets daily. All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to ensure the continued performance of their intended function. Silt fence and sediment control logs will require periodic replacement. Maintenance is the responsibility of the contractor. All disturbed areas must be seeded and mulched within 30 days of the project’s start. Vegetation shall not be considered established until a ground cover is achieved, which is demonstrated to be mature enough to control soil erosion to the satisfaction of the City Inspector and to survive severe weather conditions. Page 12 CONCLUSIONS This Preliminary Drainage Report for the Union Park property has been prepared to comply with the stormwater criteria set by the City of Fort Collins. The proposed development’s drainage system will be designed to convey the developed peak storm water runoff through the site to the existing storm drain system and to the development’s detention, water quality, and LID facilities. Storm drains will be sized to provide the required roadway relief in both the 2-yr and 100-yr storm events, and to adequately convey the released runoff from the detention ponds disbursed throughout the site. Overland relief will be provided at all sump locations. The calculated 100-yr peak flows released from the Union Park property will adhere to the allowed rates as established in the Front Range Village & Affinity Fort Collins drainage studies. This Preliminary drainage report anticipates the implementation of best management practices for erosion control, temporary and permanent, and on-site construction facilities that will be further designed and detailed in future Preliminary and Final Drainage Reports. It can therefore be concluded that the development of the Union Park property will comply with the stormwater jurisdictional criteria and will not adversely affect the adjacent properties, streets, storm drain system and/or detention/water quality facilities. Controlling the developed runoff from these improvements will improve the current situation currently existing on the site. Therefore, this preliminary report satisfies the burden of proof needed to proceed to the Final Drainage Report. Page 13 REFERENCES 1. Urban Storm Drainage Criteria Manual (Volumes 1, 2, and 3), Urban Drainage and Flood Control District, Revised August 2018. 2. Fort Collins Stormwater Criteria Manual, Fort Collins Utilities, City of Fort Collins, Colorado, Dated November 2018 3. “Final Drainage Report for Affinity Fort Collins,” prepared by JR Engineering, LLC, Dated March 2, 2016. 4. “Final Drainage and Erosion Control Study for Front Range Village, Fort Collins, Colorado,” Prepared by Stantec Consulting, Inc., dated February 2007. 5. “Preliminary Geotechnical Subsurface Exploration Report Proposed Ziegler-Corbett Mixed-Use Development” Prepared by Soilogic, Inc., dated April 4, 2022. Page 14 APPENDIX Appendix A – Site Vicinity Map & References Appendix B – Rational Calculations Appendix C – Detention Pond Calculations Appendix D – Street Capacity Calculations Appendix E – Low Impact Development Calculations Appendix A APPENDIX A – SITE VICINITY MAP & REFERENCES ZI E G L E R R D E. HARMONY RD PADDINGTON RD CO R B E T T D R KI N G S L E Y D R SITE Vicinity Map Scale: 1" = 1000' PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK #14-94 NORTHWEST CORNER OF HEWLETT PACKARD PROPERTY ON EAST SIDE ZIEGLER RD., ON THE NORTHWEST CORNER OF THE CONCRETE BASE OF A NATURAL GAS UNIT HOUSING. ELEV= 4927.83 CITY OF FORT COLLINS BENCHMARK #6-07 SOUTHEAST CORNER OF HARMONY RD. AND ZIEGLER RD. 50 FEET +/- SOUTH OF THE EDGE OF ASPHALT ON THE WALL OF A CONCRETE IRRIGATION DROP STRUCTURE. ELEV= 4931.08 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATIONS SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = 4927.83 (NAVD88 DATUM) - 3.19' NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = 4931.08 (NAVD88 DATUM) - 3.19' PRELIMINARY GEOTECHNICAL SUBSURFACE EXPLORATION REPORT PROPOSED ZIEGLER-CORBETT MIXED-USE DEVELOPMENT 4105 ZIEGLER ROAD, FORT COLLINS, COLORADO SOILOGIC # 22-1062 April 4, 2022 Soilogic, Inc. 3522 Draft Horse Court • Loveland, CO 80538 • (970) 535-6144 April 4, 2022 Landmark Homes 6341 Fairgrounds Avenue, Suite 100 Windsor, Colorado 80550 Attn: Mr. Andrew Quest Re: Preliminary Geotechnical Subsurface Exploration Report Proposed Ziegler-Corbett Mixed-Use Development Larimer County Parcel #’s 8732400010, 8732400009 and 8732000002 4105 Ziegler Road, Fort Collins, Colorado Soilogic Project # 22-1062 Mr. Quest: Soilogic, Inc. (Soilogic) personnel have completed the preliminary geotechnical subsurface exploration you requested for the proposed mixed-use development to be constructed on a combined property consisting of Larimer County Parcel Numbers 8732400010, 8732400009 and 8732000002, located at 4105 Ziegler Road in Fort Collins, Colorado. The results of our subsurface exploration and pertinent geotechnical engineering recommendations are included with this report. In summary, approximately 4 to 6 inches of vegetation and topsoil was encountered at the surface at the boring locations, underlain by brown/beige/rust lean clay with varying amounts of sand which varied to clayey sand in places. The apparently-natural lean clay/ clayey sand varied from soft to hard in terms of consistency or from very loose to medium dense in terms of relative density, typically exhibited no to low swell potential at in-situ moisture and density conditions (however one sample of sandy lean clay obtained from boring B-2 at a depth of about 9 feet below ground surface exhibited moderate swell potential) and extended to the bottom of each of the borings at a depth of approximately 15 feet below present site grades. Groundwater was not encountered in borings B-1, B-2, B-3 or B-5 to the depths explored (about 15 feet below ground surface), but was measured at a depth of about 15 feet below ground surface in boring B-4 when checked immediately after completion of drilling. When checked about five (5) days after drilling, borings B-1, B-2 and B-5 remained dry to the approximate depth explored, while groundwater was measured at a depth of about 14 Preliminary Geotechnical Subsurface Exploration Report Proposed Ziegler-Corbett Mixed-Use Development 4105 Ziegler Road, Fort Collins, Colorado Soilogic # 22-1062 4 from boring B-2 at a depth of about 9 feet below ground surface exhibited moderate swell potential) and extended to the bottom of each of the borings at a depth of approximately 15 feet below present site grades. The stratigraphy indicated on the included boring logs represents the approximate location of changes in soil types. Actual changes may be more gradual than those indicated. Groundwater was not encountered in borings B-1, B-2, B-3 or B-5 to the depths explored (about 15 feet below ground surface), but was measured at a depth of about 15 feet below ground surface in boring B-4 when checked immediately after completion of drilling. When checked about five (5) days after drilling, borings B-1, B-2 and B-5 remained dry to the approximate depth explored, while groundwater was measured at a depth of about 14 feet below ground surface at the locations of borings B-3 and B-4 at that time. Groundwater information is indicated in the upper right-hand corner of the attached boring logs. Groundwater levels will vary seasonally and over time based on weather conditions, site development, irrigation practices and other hydrologic conditions. Perched and/or trapped groundwater conditions may also be encountered at times throughout the year. Perched water is commonly encountered in soils overlying less permeable soil layers and/or bedrock. Trapped water is typically encountered within more permeable zones of layered soil and bedrock systems. The location and amount of perched/trapped water can also vary over time. ANALYSIS AND RECOMMENDATIONS General Based on the subsurface conditions encountered in the completed site borings, results of field and laboratory testing and type of construction anticipated, we expect relatively lightly-loaded commercial/retail and residential structures could be constructed with conventional footing foundations and floor slabs bearing on natural site lean clay/clayey sand with no to low swell potential or a suitable zone of properly moisture conditioned Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/1/2021 Page 1 of 4 44 8 6 3 6 0 44 8 6 4 2 0 44 8 6 4 8 0 44 8 6 5 4 0 44 8 6 6 0 0 44 8 6 6 6 0 44 8 6 7 2 0 44 8 6 3 6 0 44 8 6 4 2 0 44 8 6 4 8 0 44 8 6 5 4 0 44 8 6 6 0 0 44 8 6 6 6 0 44 8 6 7 2 0 497700 497760 497820 497880 497940 498000 498060 498120 498180 498240 498300 497700 497760 497820 497880 497940 498000 498060 498120 498180 498240 498300 40° 31' 53'' N 10 5 ° 1 ' 3 8 ' ' W 40° 31' 53'' N 10 5 ° 1 ' 1 1 ' ' W 40° 31' 39'' N 10 5 ° 1 ' 3 8 ' ' W 40° 31' 39'' N 10 5 ° 1 ' 1 1 ' ' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 100 200 400 600 Feet 0 40 80 160 240 Meters Map Scale: 1:2,940 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 16, Sep 2, 2021 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Aug 11, 2018—Aug 12, 2018 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/1/2021 Page 2 of 4 Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 73 Nunn clay loam, 0 to 1 percent slopes C 26.6 91.7% 74 Nunn clay loam, 1 to 3 percent slopes C 2.4 8.3% Totals for Area of Interest 29.0 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/1/2021 Page 3 of 4 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 10/1/2021 Page 4 of 4 Union Park Site Flow Rate to Union Park site from Affinity=116.0 cfs Union Park Site Affinity Pond D 100-yr Overflow = 116.0 cfs TRACT H FRONT RANGE VILLAGE LOT 11 FRONT RANGE VILLAGE LOT 16 FRONT RANGE VILLAGE LOT 12 FRONT RANGE VILLAGE TRACT B ENGLISH RANCH SOUTH P.U.D. ENGLISH RANCH SOUTH HOA PARCEL #8732100001 BARTRAN FAMILY LLC. TRACT A ENGLISH RANCH SOUTH P.U.D. ENGLISH RANCH SOUTH HOAENGLISH RANCH SOUTH P.U.D. THIRD FILING LOT 1 AFFINITY SUBDIVISION LOT 15 FRONT RANGE VILLAGE ENGLISH RANCH SOUTH P.U.D. CO R B E T T D R I V E PAD D I N G T O N R O A D CA R R I C K R O A D ED M O N D S RO A D ZI E G L E R R O A D (R O W V A R I E S ) KINGSLEY COURT NEWBURY COURT HARRINGTON COURT PARCEL 2 3.879± acres PARCEL 1 27.430± acres PROPOSED DETENTION POND 1 VOLUME PROVIDED=10.7± ACRE-FT 2.4± SURFACE ACRES AVAILABLE WATER CONNECTION AVAILABLE WATER CONNECTION AVAILABLE WATER CONNECTION AVAILABLE SANITARY OUTFALL AVAILABLE SANITARY OUTFALL AREA OF INADVERTENT DETENTION 7.5± ACRE-FT LOT 10 FRONT RANGE VILLAGE INADVERTENT DETENTION SPILL LOCATION OFFSITE AFFINITY SPILL LOCATION FULL MOVEMENT ACCESS (SIGNALIZED) BIKE & PEDESTRIAN ACCESS ONLY PARCEL 3 1.466± acres STORM DRAIN OUTFALL (CONNECT TO EX) PROPOSED DETENTION POND 2 VOLUME PROVIDED=5.6± ACRE-FT 1.4 ± SURFACE ACRES HIDDEN POND DRIVE RE V I S I O N NO . BY DA T E HI G H L A N D DE V E L O P M E N T S E R V I C E S 63 5 5 F A I R G R O U N D S A V E N U E , S U I T E 1 0 0 | W I N D S O R , C O 8 0 5 5 0 PH O N E : 9 7 0 . 6 7 4 . 7 5 5 0 | E M A I L : I n f o @ H i g h l a n d - D S . c o m | w w w . H i g h l a n d - D S . c o m PREPARED BY OR UNDER THE DIRECT SUPERVISION OF: FOR AND ON BEHALF OF HIGHLAND DEVELOPMENT SERVICES OFSHEET DRAWN BY CHECKED BY DATE SCALE (H) HDS PROJECT # SCALE (V) ZI E G L E R - C O R B E T T AM E N D E D O V E R A L L D E V E L O P M E N T P L A N MA S T E R U T I L I T Y & O V E R A L L D R A I N A G E P L A N 11/11/22 1" = 80' N/A JTC JTC 21-1044-00 ODP 1 1 N W E S 0 SCALE: 1" = 80' 160804080 NOTES 1.TOTAL SITE AREA IS 32.78± ACRES. 2.BOUNDARY, UTILITY AND TOPOGRAPHICAL INFORMATION PROVIDED BY ALTA LAND TITLE SURVEY PREPARED BY MAJESTIC SURVEYING, DATED 9-24-21. 3.PROJECT VERTICAL DATUM IS ON NAVD88. 4.WATER SERVICE TO BE PROVIDED BY THE CITY OF FORT COLLINS UTILIZING MAIN WITHIN CORBETT DRIVE AND ZIEGLER ROAD. 5.SEWER SERVICE TO BE PROVIDED BY THE CITY OF FORT COLLINS UTILIZING 30" MAIN ALONG THE WEST SIDE OF ZIEGLER ROAD AND/OR THE 8" MAIN ALONG EAST SIDE OF CORBETT DRIVE. 6.STORMWATER OUTFALL PROVIDED BY THE EXISTING 24" STORM DRAIN STUB, IN COMBINATION WITH ADEQUATELY SIZED SPILLWAYS. 7.ALL POINTS OF ACCESS, POINTS OF UTILITY CONNECTIONS, AND STORMWATER DETENTION LOCATIONS ARE CONCEPTUAL AND ARE SUBJECT TO CHANGE WITH SUBSEQUENT PROJECT DEVELOPMENT APPLICATIONS. Ziegler-Corbett Inadvertent Detention Volume Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Stage Storage Volume (pond volume calculated using the prismoidal formula): CONTOUR (FT)AREA (FT2) AREA (ACRE) VOLUME (ACRE-FT) DEPTH (FT) CUMULATIVE VOLUME (ACRE-FT) 4925.00 0 0.00 0.00 0.00 0.00 4926.00 3144 0.07 0.02 1.00 0.02 4927.00 164156 3.77 1.45 2.00 1.48 4928.00 377427 8.66 6.05 3.00 7.53 J.Claeys Highland Development 21-1044-00 November 9, 2022 *Inadvertant spill elevation = 4928.00 ft Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, Revised August 2018 () 3 2121 DepthAAAAV++= 21-1044-00 Inadvertant Detention.xls Page 1 of 1 Highland Development Services Appendix B APPENDIX B – RATIONAL CALCULATIONS D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE UPUP UPUP UP OFFSITE AFFINITY SPILL LOCATION KINGSLEY COURT NEWBURY COURT HARRINGTON COURT CO R B E T T D R I V E LO T 1 AFF I N I T Y S U B D I V I S I O N LID D2 STORMTECH MC-3500 (47 CHAMBERS) POND 298A AREA=2.22 AC VOLUME=11.66 AC-FT SPILLWAY ELEV=4936.00 MA T C H L I N E SE E S H E E T 8 AFFINITY OUTFALL ROUTED THROUGH POND & SITE BLDG ENVELOPE A1 BLDG ENVELOPE A2 BLDG ENVELOPE A3 BLDG ENVELOPE A4 BLDG ENVELOPE A10 BLDG ENVELOPE A11 BE AG1 BE AG2 BE AG3BE G1 BE G2 BLDG ENVELOPE R1 BLOCK 1 BLOCK 2 BLOCK 3 BLOCK 4BLOCK 5BLOCK 6 BLOCK 7 BLOCK 8 BLOCK 9 BLOCK 10BLOCK 11BLOCK 12 BLOCK 13 BLOCK 18 BLOCK 19 BLOCK 24 TRACT A ACCESS, DRAINAGE & UTILITY EASEMENT ST R E E T - 0 6 STREET-04 STREET-03 STREET-02 STREET-01 ST R E E T - 0 5 RE V I S I O N NO . BY DA T E HI G H L A N D DE V E L O P M E N T S E R V I C E S 63 5 5 F A I R G R O U N D S A V E N U E , S U I T E 1 0 0 | W I N D S O R , C O 8 0 5 5 0 PH O N E : 9 7 0 . 6 7 4 . 7 5 5 0 | E M A I L : I n f o @ H i g h l a n d - D S . c o m | w w w . H i g h l a n d - D S . c o m PREPARED BY OR UNDER THE DIRECT SUPERVISION OF: FOR AND ON BEHALF OF HIGHLAND DEVELOPMENT SERVICES REVIEW SET NOT FOR CONSTRUCTION OFSHEET DRAWN BY CHECKED BY DATE SCALE (H) HDS PROJECT # SCALE (V) UN I O N P A R K GR A D I N G & D R A I N A G E P L A N 12/06/23 1" = 40' N/A JTC JTC 21-1044-00 C2.00 7 11 BASIN COEFFICIENT (100-YR) BASIN DESIGNATION BASIN AREA DESIGN POINT DRAINAGE FLOW ARROW DRAINAGE BASIN BOUNDARY DRAINAGE BASIN FLOW PATH LEGEND EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR N W E S 0 SCALE: 1" = 40' 80402040 CALL UTILITY NOTIFICATION CENTER OF COLORADO CALL 2-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. before you dig.CallKnow what's below. R D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTED D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRONRAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTE D D UCTILEIRON RAINSTOWATERWAYSNYLOPLAST DONOTPOLLUTEDNDYLOPLASTONOTPOLLUTE UCTILEIRON DRAINSTOWATERWAYS UPUP UPUP UPUP INADVERTENT DETENTION SPILL LOCATION LID D4 STORMTECH MC-3500 (35 CHAMBERS) ZI E G L E R R O A D (R O W V A R I E S ) MA T C H L I N E SE E S H E E T 7 POND 298C AREA=1.17 AC VOLUME=4.21 AC-FT SPILLWAY ELEV=4929.0 POND 298C AREA=1.17 AC VOLUME=4.21 AC-FT SPILLWAY ELEV=4929.0 STORM OUTFALL 20.1 CFS LIMITED POND 298B AREA=0.36 AC VOLUME=0.42 AC-FT SPILLWAY ELEV=4932.0 LID D3 STORMTECH MC-3500 (24 CHAMBERS) BLDG ENVELOPE A4 BLDG ENVELOPE A5 BLDG ENVELOPE A6 BLDG ENVELOPE A7 BLDG ENVELOPE A8 BLDG ENVELOPE A9 BE AG3 BE AG4 BE AG5BE G3 BE G4 BE G5 BLDG ENVELOPE C1 BLDG ENVELOPE C2 BLDG ENVELOPE C3 BE MU1 BE MU2 BLOCK 13 BLOCK 14 BLOCK 15 BLOCK 16BLOCK 17BLOCK 18 BLOCK 19 BLOCK 20 BLOCK 21 BLOCK 22BLOCK 23BLOCK 24 BL O C K 2 5 BL O C K 2 6 TRACT A ACCESS, DRAINAGE & UTILITY EASEMENT ST R E E T - 0 7 STREET-02 STREET-03 ST R E E T - 0 7 STREET-04 ZI E G L E R R O A D (R O W V A R I E S ) STREET-01 RE V I S I O N NO . BY DA T E HI G H L A N D DE V E L O P M E N T S E R V I C E S 63 5 5 F A I R G R O U N D S A V E N U E , S U I T E 1 0 0 | W I N D S O R , C O 8 0 5 5 0 PH O N E : 9 7 0 . 6 7 4 . 7 5 5 0 | E M A I L : I n f o @ H i g h l a n d - D S . c o m | w w w . H i g h l a n d - D S . c o m PREPARED BY OR UNDER THE DIRECT SUPERVISION OF: FOR AND ON BEHALF OF HIGHLAND DEVELOPMENT SERVICES REVIEW SET NOT FOR CONSTRUCTION OFSHEET DRAWN BY CHECKED BY DATE SCALE (H) HDS PROJECT # SCALE (V) UN I O N P A R K GR A D I N G & D R A I N A G E P L A N 12/06/23 1" = 40' N/A JTC JTC 21-1044-00 C2.01 8 11 BASIN COEFFICIENT (100-YR) BASIN DESIGNATION BASIN AREA DESIGN POINT DRAINAGE FLOW ARROW DRAINAGE BASIN BOUNDARY DRAINAGE BASIN FLOW PATH LEGEND EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR N W E S 0 SCALE: 1" = 40' 80402040 CALL UTILITY NOTIFICATION CENTER OF COLORADO CALL 2-BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. before you dig.CallKnow what's below. R Design Engineer: Design Firm: Project Number: Date: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 D1 116,568 2.676 0 3,254 7,781 0 105,533 8.5% 0.32 0.40 D2 396,199 9.095 149,490 138,147 20,445 0 88,117 73.8% 0.79 0.99 D3 214,255 4.919 59,507 78,039 18,255 0 58,454 68.2% 0.76 0.95 D4 300,805 6.906 111,885 98,730 19,415 0 70,776 72.5% 0.79 0.98 D5 367,308 8.432 125,481 93,071 23,595 0 125,161 62.7% 0.71 0.89 D total 1,395,134 32.028 446,363 411,241 89,490 0 448,040 64.3% 0.73 0.91 COMPOSITEApaved (sq feet) Aroof (sq feet) Awalk (sq feet) Agravel/pavers (sq feet) Alawn (sq feet) Lawns (Heavy, 2-7% Slope) Sub-basin Designation Atotal (sq feet) Atotal (acres) Weighted % Impervious Paved Roof Walks Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual Gravel/Pavers % Impervious values from Table 3.2.2 in the Fort Collins Stormwater Criteria Manual J.Claeys 21-1044-00 December 5, 2023 Land Use Union Park DEVELOPED IMPERVIOUS AREA CALCULATION DESIGN CRITERIA: Fort Collins Stormwater Criteria Manual BASINS: Highland Development Services 21-1044-00 Rational Calcs.xlsx Page 1 of 4 Highland Development Services Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 5-3 -Equation 5-4 -Urbanized Check Equation 3.3-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (2-yr to 10-yr) D1 D1 8.5% 0.32 2.676 279 0.0429 15.07 61 0.0051 0.10 0.016 1.43 0.71 15.79 341 11.89 11.89 D2 D2 73.8% 0.79 9.095 49 0.0395 2.53 929 0.0064 0.10 0.016 1.60 9.68 12.21 978 15.43 12.21 D3 D3 68.2% 0.76 4.919 30 0.0200 2.77 851 0.0050 0.10 0.016 1.42 10.00 12.77 881 14.89 12.77 D4 D4 72.5% 0.79 6.906 44 0.0273 2.78 1049 0.0050 0.10 0.016 1.42 12.32 15.10 1092 16.07 15.10 D5 D5 62.7% 0.71 8.432 116 0.0448 4.76 605 0.0050 0.10 0.016 1.42 7.11 11.86 721 14.01 11.86 OVERALL LENGTH (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH (ft) SLOPE (ft/ft) VELOCITY (ft/s) ROUGHNESS COEFFICIENT HYDRAULIC RADIUS (ft) LENGTH (ft) DESIGN CRITERIA: City of Fort Collins Stormwater Criteria Manual Overland Flow Equations for City of Fort Collins Stormwater Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti)TRAVEL TIME (tt) tc=ti+tt (min) Urban Check Final tc (min)DESIGN POINT Sub-basin % Impervious C2-10 AREA (acres) tt (min) December 5, 2023 Union Park DEVELOPED TIME OF CONCENTRATION J.Claeys 21-1044-00 Highland Development Services ticttt+= V Ltt60 = Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 5-3 -Equation 5-4 -Urbanized Check Equation 3.3-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (100-yr) D1 D1 8.5% 0.40 2.676 279 0.0429 13.55 61 0.0051 0.10 0.016 1.43 0.71 14.27 341 11.89 11.89 D2 D2 73.8% 0.99 9.095 49 0.0395 0.89 929 0.0064 0.10 0.016 1.60 9.68 10.56 978 15.43 10.56 D3 D3 68.2% 0.95 4.919 30 0.0200 1.23 851 0.0050 0.10 0.016 1.42 10.00 11.23 881 14.89 11.23 D4 D4 72.5% 0.98 6.906 44 0.0273 1.04 1049 0.0050 0.10 0.016 1.42 12.32 13.36 1092 16.07 13.36 D5 D5 62.7% 0.89 8.432 116 0.0448 2.58 605 0.0050 0.10 0.016 1.42 7.11 9.68 721 14.01 9.68 OVERALL LENGTH (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH (ft) SLOPE (ft/ft) VELOCITY (ft/s) HYDRAULIC RADIUS (ft) ROUGHNESS COEFFICIENT LENGTH (ft) DESIGN CRITERIA: City of Fort Collins Stormwater Criteria Manual Overland Flow Equations for City of Fort Collins Stormwater Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti)TRAVEL TIME (tt) tc=ti+tt (min) Urban Check Final tc (min)DESIGN POINT Sub-basin % Impervious C100 AREA (acres) tt (min) December 5, 2023 Union Park DEVELOPED TIME OF CONCENTRATION J.Claeys 21-1044-00 Highland Development Services ticttt+= V Ltt60 = Design Engineer: Design Firm: Project Number: Date:February 15, 2023 EQUATIONS:I = rainfall intensity (in/hr) Q n = n -yr peak discharge (cfs)P 1 = one-hour point rainfall depth (in) C n = n -yr runoff coefficient t c = time of concentration (min) I n = n -yr rainfall intensity (in/hr) P 1-2yr =0.82 in A n = Basin drainage area (ac)P 1-10yr =1.40 in P 1-100yr =2.86 in BASIN SUMMARY: tc (min)Runoff Coeff (C2-10)C(A) (acres)Intensity (in/hr)Q (ft3/s)tc (min)Runoff Coeff (C2-10)C(A) (acres)Intensity (in/hr)Q (ft3/s)tc (min)Runoff Coeff. (C100)C(A) (acres)Intensity (in/hr)Q (ft3/s) D1 D1 2.676 8.5% 11.89 0.32 0.85 2.06 1.75 11.89 0.32 0.85 3.52 2.98 11.89 0.40 1.06 7.19 7.61 D2 D2 9.095 73.8% 12.21 0.79 7.22 2.04 14.73 12.21 0.79 7.22 3.48 25.15 10.56 0.99 9.03 7.56 68.23 D3 D3 4.919 68.2% 12.77 0.76 3.73 2.00 7.46 12.77 0.76 3.73 3.41 12.74 11.23 0.95 4.67 7.37 34.39 D4 D4 6.906 72.5% 15.10 0.79 5.42 1.85 10.04 15.10 0.79 5.42 3.16 17.15 13.36 0.98 6.78 6.83 46.32 D5 D5 8.432 62.7% 11.86 0.71 6.00 2.06 12.38 11.86 0.71 6.00 3.52 21.14 9.68 0.89 7.50 7.82 58.64 10-yr Peak Runoff 100-yr Peak Runoff Union Park DEVELOPED PEAK RUNOFF DESIGN CRITERIA: Design Point Sub-basin Area (acres) J.Claeys Highland Development Services 21-1044-00 2-yr Peak Runoff City of Fort Collins Stormwater Criteria Manual % Impervious nnnnAICQ=(0.786651) 1 )10( 5.28 ct PI + = 21-1044-00 Rational Calcs.xlsx Page 4 of 4 Highland Development Services Appendix C APPENDIX C – DETENTION POND CALCULATIONS Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA 0.73 1.25 0.91 ft3 acre-ft 32.03 acres 336,708 7.73 7.01 cfs Time (min) 100-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.00 0.00 0 0 0 0.00 5 9.95 290.79 87,238 2,103 85,135 1.95 10 7.72 225.62 135,373 4,206 131,167 3.01 15 6.52 190.55 171,496 6,309 165,187 3.79 20 5.60 163.66 196,396 8,412 187,984 4.32 25 4.98 145.54 218,315 10,515 207,800 4.77 30 4.52 132.10 237,779 12,618 225,161 5.17 35 4.08 119.24 250,405 14,721 235,684 5.41 40 3.74 109.30 262,329 16,824 245,505 5.64 45 3.46 101.12 273,025 18,927 254,098 5.83 50 3.23 94.40 283,196 21,030 262,166 6.02 55 3.03 88.55 292,226 23,133 269,093 6.18 60 2.86 83.59 300,906 25,236 275,670 6.33 65 2.72 79.49 310,025 27,339 282,686 6.49 70 2.59 75.69 317,916 29,442 288,474 6.62 75 2.48 72.48 326,157 31,545 294,612 6.76 80 2.38 69.56 333,873 33,648 300,225 6.89 85 2.29 66.93 341,325 35,751 305,574 7.02 90 2.21 64.59 348,778 37,854 310,924 7.14 95 2.13 62.25 354,827 39,957 314,870 7.23 100 2.06 60.20 361,228 42,060 319,168 7.33 105 2.00 58.45 368,242 44,163 324,079 7.44 110 1.94 56.70 374,204 46,266 327,938 7.53 115 1.89 55.24 381,130 48,369 332,761 7.64 120 1.84 53.78 387,180 50,472 336,708 7.73 Union Park 100-yr Detention Volume - FAA Method Highland Development Services December 5, 2023 21-1044-00 J.Claeys Area (A ) Allowed Release Rate Fort Collins Stormwater Criteria Manual, December 2018 Runoff Coefficient (C ) Frequency Factor (C f )Required Detention Adjusted Runoff Coefficient (CC f ) Developed Detention Volume Calculation Union Park Critical Pond Elevations Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Stage Storage - Pond 298a Volume (pond volume calculated using the prismoidal formula): CONTOUR (FT)AREA (FT2) AREA (ACRE) VOLUME (ACRE-FT) DEPTH (FT) CUMULATIVE VOLUME (ACRE- FT) 4926.50 0.000 0.000 0.00 0.000 4927.0 1,582 0.036 0.006 0.50 0.006 4928.0 16,848 0.387 0.181 1.50 0.187 4929.0 42,452 0.975 0.658 2.50 0.845 4930.0 55,814 1.281 1.124 3.50 1.969 4931.0 61,829 1.419 1.350 4.50 3.319 4932.0 63,775 1.464 1.442 5.50 4.761 4933.0 66,216 1.520 1.492 6.50 6.253 4934.0 73,768 1.693 1.606 7.50 7.859 4935.0 83,670 1.921 1.806 8.50 9.665 4936.0 90,558 2.079 1.999 9.50 11.664 Spillway 4937.0 96,883 2.224 2.151 10.50 13.815 Northwest POND J. Clayes Highland Development 21-1044-00 December 5, 2023 () 3 2121 DepthAAAA V ++ = 21-1044-00 PondCalcs.xls - Pond A Stage Storage Page 1 of 3 Highland Development Services Union Park Critical Pond Elevations Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Stage Storage - Pond 298b Volume (pond volume calculated using the prismoidal formula): CONTOUR (FT)AREA (FT2) AREA (ACRE) VOLUME (ACRE-FT) DEPTH (FT) CUMULATIVE VOLUME (ACRE- FT) 4929.50 0.000 0.000 0.00 0.000 4930.0 1,583 0.036 0.006 0.50 0.006 4931.0 11,431 0.262 0.132 1.50 0.138 4932.0 13,208 0.303 0.283 2.50 0.421 Spillway 4933.0 15,540 0.357 0.330 3.50 0.750 J. Clayes Highland Development 21-1044-00 December 5, 2023 Northwest POND () 3 2121 DepthAAAA V ++ = 21-1044-00 PondCalcs.xls - Pond B Stage Storage Page 2 of 3 Highland Development Services DESIGN CRITERIA Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Water Quality Capture Volume (WQCV): Tributary Area, A 8.432 acres Basin D5 (not treated by LID) Composite. Imperviousness, I 62.7% WQCV (watershed inches) 0.246 inches 40-Hour Drain Time (Fig SQ-2) Required WQCV 0.207 acre-feet Including 20% for Sedimentation Stage Storage - Pond 298c Volume (pond volume calculated using the prismoidal formula): CONTOUR (FT)AREA (FT2) AREA (ACRE) VOLUME (ACRE-FT) DEPTH (FT) CUMULATIVE VOLUME (ACRE- FT) 4922.30 0 0.000 0.000 0.00 0.000 4923.0 4,670 0.107 0.025 0.70 0.025 4924.0 19,830 0.455 0.261 1.70 0.286 4925.0 28,280 0.649 0.549 2.70 0.835 4926.0 30,824 0.708 0.678 3.70 1.514 4927.0 37,770 0.867 0.786 4.70 2.300 4928.0 41,379 0.950 0.908 5.70 3.208 4929.0 46,356 1.064 1.007 6.70 4.214 Spillway 4930.0 50,428 1.158 1.111 7.70 5.325 0.207 4923.70 ft Southeast POND Required Water Quality Capture Volume (WQCV) = Acre-Ft Interpolates to an Elev. of () 3 2121 DepthAAAAV++ = 21-1044-00 PondCalcs.xls - Pond C Stage Storage Page 3 of 3 Highland Development Services Appendix D APPENDIX D – STREET CAPACITY CALCULATIONS Channel Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc.Wednesday, Feb 22 2023 26' Inverted Street User-defined Invert Elev (ft) = 100.00 Slope (%) = 0.50 N-Value = Composite Calculations Compute by: Q vs Depth No. Increments = 20 (Sta, El, n)-(Sta, El, n)... ( -15.67, 100.76)-(2.00, 100.17, 0.013)-(15.00, 100.43, 0.013)-(15.67, 100.76, 0.013) Highlighted Depth (ft) = 0.76 Q (cfs) = 73.08 Area (sqft) = 14.88 Velocity (ft/s) = 4.91 Wetted Perim (ft) = 31.51 Crit Depth, Yc (ft) = 0.76 Top Width (ft) = 31.34 EGL (ft) = 1.13 -5 0 5 10 15 20 25 Elev (ft)Depth (ft)Section 99.75 -0.25 100.00 0.00 100.25 0.25 100.50 0.50 100.75 0.75 101.00 1.00 Sta (ft) Channel Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc. Wednesday, Sep 6 2023 36' Crowned Street User-defined Invert Elev (ft) = 99.51 Slope (%) = 0.50 N-Value = 0.016 Calculations Compute by: Known Depth Known Depth (ft) = 0.99 (Sta, El, n)-(Sta, El, n)... ( -46.50, 100.58)-(16.00, 99.68, 0.013)-(18.00, 99.51, 0.013)-(18.04, 100.01, 0.013)-(26.50, 100.18, 0.020)-(31.50, 100.28, 0.013)-(46.50, 100.58, 0.020) Highlighted Depth (ft) = 0.99 Q (cfs) = 134.36 Area (sqft) = 36.77 Velocity (ft/s) = 3.65 Wetted Perim (ft) = 85.95 Crit Depth, Yc (ft) = 0.99 Top Width (ft) = 85.00 EGL (ft) = 1.20 -10 0 10 20 30 40 50 60 Elev (ft) Depth (ft)Section 99.00 -0.51 99.50 -0.01 100.00 0.49 100.50 0.99 101.00 1.49 Sta (ft) Depth @ flowline w/ 0.5' depth at crown Appendix E APPENDIX E – LOW IMPACT DEVELOPMENT CALCULATIONS Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Low Impact Development Summary Sq-Ft Acres Impervious Area (sq-ft) % of Impervious Area Requiring Treatment Impervious Area Requiring Treatment 1,427,723 32.78 947,095 75% 710,321 LID Facility Contributing Basins Area Drainage to LID (sq-ft) % Impervious Impervious Area Treated (sq-ft) WQCV12-hr (watershed inches) WQCV12-hr (cu-ft) Treatment Method D2 D2 396,199 73.8% 308,082 0.23 7,747 Filtration Gallery D3 D3 214,255 68.2% 155,802 0.21 3,816 Filtration Gallery D4 D4 300,805 72.5% 230,029 0.23 5,751 Filtration Gallery EDB Pond Contributing Basins Drainage Area (sq-ft) Drainage Area (sq-ft)% Impervious WQCV40-hr (watershed inches) WQCV40-hr (ac-ft) Pond 298C D5 367,308 8.43 62.7% 0.25 0.207 710,321 693,913 73.3% 97.7% Area (sq-ft) Area (acres) Treatment Ratio 911,259 20.92 63.8% 367,308 8.43 25.7% 1,278,567 29.35 89.6% 149,156 3.42 10.4% 1,427,723 32.78 Description Total Improvement Area Water Quality Area Treatment Summary Description Total Area Treated by LID Total Area Treated by EDB Total Untreated Area (includes Pond 298A) Total Treated Area Total % of Imervious Area Treated Development Area Union Park Low Impact Development Total % of Required Treatment Development Area Breakdown City of Fort Collins - Ordinance No. 007, 2016 - Treat at least 75% of any newly developed or redeveloped impervious area using one or a combination of LID techniques, or - Treat at least 50% of any newly developed or redeveloped impervious area using one or a combination of LID techniques when 25% of private driveable surfaces are permeable. Total Impervious Area Treated (sq-ft) Total Impervious Area Required for LID Treatment (sq-ft) LID Treatment Summary LID Treatment Areas J.Claeys Highland Development Services 21-1044-00 December 6, 2023 Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Standard Water Quality Areas Allowed Filter Fabric Flow Ratea (cfs) 0.35 gpm/sq-ft SC-106LP 14 10 6 6 85.4 25 12 14.8 0.012 6.9 15.0 SC-310 18 8 6 6 85.4 34 16 20.2 0.016 14.7 31.0 SC-740 18 8 6 6 85.4 51 30 30.2 0.024 45.9 74.9 DC-780 18 12 6 9 85.4 51 30 30.2 0.024 46.2 78.4 MC-3500 24 8 12 9 90 77 45 48.1 0.038 109.9 178.9 14.9 46 MC-4500 24 7 12 9 52 100 60 36.1 0.028 106.5 162.6 35.7 108.7 LID Facility Chamber Type Total Release Ratef (cfs) WQ Inflowg (cfs) Req'd Storage Volumeh (cu-ft) Minimum No. of Chambersi Chamber Storagej (cu-ft) No. of Endcapsk Endcap Storagel (cu-ft) Total Chamber Volumem (cu-ft) Total Installed System Volumen (cu-ft) WQCV12-hr (cu-ft) D2 MC-3500 1.75 7.37 5,252 47 5,133 8 119 5,252 9,331 7,747 D3 MC-3500 0.90 3.73 2,760 24 2,626 9 134 2,760 5,005 3,816 D4 MC-3500 1.32 5.02 4,010 35 3,861 8 119 3,980 7,119 5,751 Max Cover (ft) Min Cover (in) Chamber Model J.Claeys Highland Development Services 21-1044-00 December 6, 2023 Min Installed Chamber/Aggregate Volumec (cu-ft) Union Park Low Impact Development StormTech Chamber Configuration Summary StormTech Chamber Data Design Engineer: Design Firm: Project Number: Date: Length (in) Width (in) Height (in) Floor Area (sq-ft) Chamber Volumeb (cu-ft) Min Aggregate Base (in) Min Aggregate Cover (in) Negligible Endcap Volumed (cu-ft) Min Installed Endcap/Aggregate Volumee (cu-ft) Negligible Negligible Negligible Note: a. Release rate per chamber, limited by flow through geotextile with accumulated sediment. City acceptable flow rates determined to be approximately 1/2 of the Nov-07 Qmax from Figure 17 of the "Final Report on Field Verification Testing of the StormTech Isoloator Row Treatement Unit", prepard by the University of New Hamphire Stormwater Center, dated Setpember 2010. b. Volume within chamber only, not accounting for void spaces in surrounding aggregate. c. Volume includes chamber and void spaces (40%) in surrounding aggregate, per chamber unit. d. Volume within endcap only, not accounting for void spaces in surrounding aggregate. e. Volume includes endcap and void spaces (40%) in surrounding aggregate, per chamber unit. f. Release rate per chamber times number of chambers. This is used as the allowed release rate for the FAA calculations. g. WQ flow, equal to 1/2 of the 2-yr peak runoff rate, referenced to size flow control structure. h. Required detention volume determined using the FAA Method based on the acceptable release rate of sediment accumulated filter fabric of the chambers and the 1/2 of the 2yr in flow rate. i. Number of chambers required to provide required FAA storage volume stored within the chamber and endcaps only (no aggregate storage). j. Total volume provided in chambers only (no aggregate storage). k. Number of endcaps based on desired chamber layout. l. Total volume provided in endcaps only (no aggregate storage). m. Total chamber and endcap storage (not aggregate storage). This number must meet or exceed the required FAA storage volume. n. System volume includes total chamber volume plus surrounding aggregate volume, assumes a 40% void ratio for aggregate storage. This total is provided from ADS Design Tool. DESIGN CRITERIA 0.79 1.00 0.79 (ft3)acre-ft 9.10 acres 5,252 0.12 1.75 cfs Time (min) 1/2 2-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Accumulative Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.000 0.00 0 0 0 0.00 5 1.425 10.24 3,072 526 2,546 0.06 10 1.105 7.94 4,764 1,052 3,712 0.09 15 0.935 6.72 6,047 1,577 4,469 0.10 20 0.805 5.78 6,941 2,103 4,838 0.11 25 0.715 5.14 7,706 2,629 5,077 0.12 30 0.650 4.67 8,407 3,155 5,252 0.12 35 0.585 4.20 8,827 3,681 5,147 0.12 40 0.535 3.84 9,226 4,207 5,020 0.12 45 0.495 3.56 9,603 4,732 4,871 0.11 50 0.460 3.31 9,916 5,258 4,658 0.11 55 0.435 3.13 10,315 5,784 4,531 0.10 60 0.410 2.95 10,606 6,310 4,296 0.10 Union Park WQ Treatment Volume - FAA Method - City of Fort Collins accepts 1/2 of the 2-yr runoff as the WQ inflow rate WQ Treatment Volume Calculation - D2 Filtration Gallery Runoff Coefficient (C ) J.Claeys Highland Development Services 21-1044-00 December 6, 2023 - City of Fort Collins - Storm Water Criteria Manual Design Engineer: Design Firm: Project Number: Date: Allowed Release Rate Frequency Factor (C f )Required Detention Adjusted Runoff Coefficient (CC f ) Area (A ) DESIGN CRITERIA 0.76 1.00 0.76 ft3 acre-ft 4.92 acres 2,760 0.06 0.90 cfs Time (min) 1/2 2-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Accumulative Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.000 0.00 0 0 0 0.00 5 1.425 5.33 1,598 269 1,329 0.03 10 1.105 4.13 2,478 538 1,940 0.04 15 0.935 3.50 3,146 807 2,339 0.05 20 0.805 3.01 3,611 1,076 2,535 0.06 25 0.715 2.67 4,009 1,345 2,664 0.06 30 0.650 2.43 4,374 1,614 2,760 0.06 35 0.585 2.19 4,592 1,883 2,709 0.06 40 0.535 2.00 4,800 2,152 2,648 0.06 45 0.495 1.85 4,996 2,421 2,575 0.06 50 0.460 1.72 5,159 2,690 2,469 0.06 55 0.435 1.63 5,366 2,959 2,407 0.06 60 0.410 1.53 5,518 3,228 2,290 0.05 Adjusted Runoff Coefficient (CC f ) Area (A ) Allowed Release Rate - City of Fort Collins - Storm Water Criteria Manual - City of Fort Collins accepts 1/2 of the 2-yr runoff as the WQ inflow rate WQ Treatment Volume Calculation - D3 Filtration Gallery Runoff Coefficient (C ) Frequency Factor (C f )Required Detention Union Park WQ Treatment Volume - FAA Method J.Claeys Highland Development Services 21-1044-00 December 6, 2023 Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA 0.79 1.00 0.79 ft3 acre-ft 6.91 acres 4,010 0.09 1.32 cfs Time (min) 1/2 2-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Accumulative Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.000 0.00 0 0 0 0.00 5 1.425 7.77 2,332 396 1,937 0.04 10 1.105 6.03 3,617 791 2,826 0.06 15 0.935 5.10 4,591 1,187 3,404 0.08 20 0.805 4.39 5,270 1,582 3,688 0.08 25 0.715 3.90 5,851 1,978 3,873 0.09 30 0.650 3.55 6,383 2,373 4,010 0.09 35 0.585 3.19 6,702 2,769 3,933 0.09 40 0.535 2.92 7,005 3,164 3,841 0.09 45 0.495 2.70 7,291 3,560 3,732 0.09 50 0.460 2.51 7,528 3,955 3,573 0.08 55 0.435 2.37 7,831 4,351 3,481 0.08 60 0.410 2.24 8,052 4,746 3,306 0.08 - City of Fort Collins accepts 1/2 of the 2-yr runoff as the WQ inflow rate Union Park WQ Treatment Volume - FAA Method Design Engineer: J.Claeys Design Firm: Highland Development Services Project Number: 21-1044-00 Date: December 6, 2023 - City of Fort Collins - Storm Water Criteria Manual Allowed Release Rate WQ Treatment Volume Calculation - D4 Filtration Gallery Runoff Coefficient (C ) Frequency Factor (C f )Required Detention Adjusted Runoff Coefficient (CC f ) Area (A ) User Inputs Chamber Model: MC-3500 Outlet Control Structure: Yes Project Name: Union Park - LID D2 Engineer: Jason Claeys Project Location: Colorado Measurement Type: Imperial Required Storage Volume: 9000 cubic ft. Stone Porosity: 40% Stone Foundation Depth: 9 in. Stone Above Chambers: 12 in. Average Cover Over Chambers: 18 in. Design Constraint Dimensions:(32 ft. x 100 ft.) Results System Volume and Bed Size Installed Storage Volume: 9331.21 cubic ft. Storage Volume Per Chamber: 109.90 cubic ft. Number Of Chambers Required: 47 Number Of End Caps Required: 8 Chamber Rows: 4 Maximum Length:95.88 ft. Maximum Width: 29.77 ft. Approx. Bed Size Required: 2800.23 square ft. System Components Amount Of Stone Required: 375 cubic yards Volume Of Excavation (Not Including Fill): 571 cubic yards Total Non-woven Geotextile Required:932 square yards Woven Geotextile Required (excluding Isolator Row): 51 square yards Woven Geotextile Required (Isolator Row): 105 square yards Total Woven Geotextile Required:155 square yards Impervious Liner Required:0 square yards User Inputs Chamber Model: MC-3500 Outlet Control Structure: Yes Project Name: Union Park - LID D3 Engineer: Jason Claeys Project Location: Colorado Measurement Type: Imperial Required Storage Volume: 4750 cubic ft. Stone Porosity: 40% Stone Foundation Depth: 9 in. Stone Above Chambers: 12 in. Average Cover Over Chambers: 18 in. Design Constraint Dimensions:(32 ft. x 80 ft.) Results System Volume and Bed Size Installed Storage Volume: 5005.02 cubic ft. Storage Volume Per Chamber: 109.90 cubic ft. Number Of Chambers Required: 24 Number Of End Caps Required: 6 Chamber Rows: 3 Maximum Length:67.01 ft. Maximum Width: 22.85 ft. Approx. Bed Size Required: 1531.28 square ft. System Components Amount Of Stone Required: 211 cubic yards Volume Of Excavation (Not Including Fill): 312 cubic yards Total Non-woven Geotextile Required:541 square yards Woven Geotextile Required (excluding Isolator Row): 34 square yards Woven Geotextile Required (Isolator Row): 72 square yards Total Woven Geotextile Required:105 square yards Impervious Liner Required:0 square yards User Inputs Chamber Model: MC-3500 Outlet Control Structure: Yes Project Name: Union Park - LID D4 Engineer: Jason Claeys Project Location: Colorado Measurement Type: Imperial Required Storage Volume: 6800 cubic ft. Stone Porosity: 40% Stone Foundation Depth: 9 in. Stone Above Chambers: 12 in. Average Cover Over Chambers: 18 in. Design Constraint Dimensions:(32 ft. x 80 ft.) Results System Volume and Bed Size Installed Storage Volume: 7118.79 cubic ft. Storage Volume Per Chamber: 109.90 cubic ft. Number Of Chambers Required: 35 Number Of End Caps Required: 8 Chamber Rows: 4 Maximum Length:74.18 ft. Maximum Width: 29.77 ft. Approx. Bed Size Required: 2154.26 square ft. System Components Amount Of Stone Required: 292 cubic yards Volume Of Excavation (Not Including Fill): 439 cubic yards Total Non-woven Geotextile Required:727 square yards Woven Geotextile Required (excluding Isolator Row): 51 square yards Woven Geotextile Required (Isolator Row): 80 square yards Total Woven Geotextile Required:130 square yards Impervious Liner Required:0 square yards HIGHLAND DEVELOPMENT SERVICES 6355 FAIRGROUNDS AVENUE, SUITE 100 | WINDSOR, CO 80550 PHONE: 970.674.7550 | EMAIL: Info@Highland-DS.com | www.Highland-DS.com DRAWN BYDATE SCALE (H)HDS PROJ # OFSHEET UNION PARK FILTRATION GALLERY INLET CONFIGURATION 12/6/23 1" = 10' JTC 21-1044-00 INLET CONFIG 1 1 2 N W E S 0 SCALE: 1" = 10' 1050 FILTRATION GALLERY GALLERY OUTLET INV = 102.00* (SUMP W/ FLOW CONTROL ORIFICE OR SD OUTLET INVERT EQUALS TOP OF GALLERY ELEVATION) SDMH INV = 100.00* *ELEVATIONS SHOWN ARE CONCEPTUAL TO DEMONSTRATE DESIGN INTENT INLET INV = 103.50* UD UD UD UD UD UD UD UD UD UD UD UD UD UD SD OUTLET INV = 103.00* UD OUTLET HIGHLAND DEVELOPMENT SERVICES 6355 FAIRGROUNDS AVENUE, SUITE 100 | WINDSOR, CO 80550 PHONE: 970.674.7550 | EMAIL: Info@Highland-DS.com | www.Highland-DS.com DRAWN BYDATE SCALE (H)HDS PROJ # OFSHEET UNION PARK FILTRATION GALLERY INLET CONFIGURATION 12/6/23 1" = 10' JTC 21-1044-00 INLET CONFIG 2 2 2 N W E S 0 SCALE: 1" = 10' 1050 FILTRATION GALLERY GALLERY OUTLET INV = 102.00* (SUMP W/ FLOW CONTROL ORIFICE OR SD OUTLET INVERT EQUALS TOP OF GALLERY ELEVATION) SDMH INV = 100.00* SD OUTLET INV = 103.00* *ELEVATIONS SHOWN ARE CONCEPTUAL TO DEMONSTRATE DESIGN INTENT SDMH INV = 103.50* UD UD UD UD UD UD UD UD OUTLET