Loading...
HomeMy WebLinkAboutTHE LANDING AT LEMAY MULTIFAMILY AND MIXED-USE - FDP230020 - SUBMITTAL DOCUMENTS - ROUND 2 - SUPPORTING DOCUMENTATIONFLAG NOTES 1 2 3 4 5 6 7 GENERAL DESCRIPTION LEGEND A-15 1" 12 M F Q A NOZZLE NUMBER ARC - QUARTER (Q), HALF (H), FULL (F)30 H B .5 R ES SS .25 GENERAL NOTES DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 1 . 0 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 2 9 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-1.0 FDP RD2 11/15/2023 01 02 IRRIGATION COVER SHEET X X X X S W S S W HY D V.P. A RV H2O TEST STA H Y D TEST STA H Y D T T T T T T T T T T T T T T IR-2.6 IR-2.5IR-2.4IR-2.3 IR-2.2IR-2.1 IR-2.0 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 1 . 1 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 3 0 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-1.1 FDP RD2 11/15/2023 01 02 IRRIGATION KEYMAP 2.5" 2.5" 2.5" 2.5" 2.5" 0'20'10'40'120' 1"=20' MATCHLINE SEE SHEET IR-2.1 MATCHLINE SEE SHEET IR-2.2 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 0 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 2 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.0 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED T T T T T T MATCHLINE SEE SHEET IR-2.1 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" 2" MATCHLINE SEE SHEET IR-2.0 MA T C H L I N E S E E S H E E T I R - 2 . 2 MATCHLINE SEE SHEET IR-2.3 MATCHLINE SEE SHEET IR-2.4 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 1 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 3 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.1 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' T T T POINT-OF-CONNECTION SOURCE: POTABLE, 2-INCH IRRIGATION METER (REFER TO CIVIL) SIZE: 2-INCH FLOW (MAXIMUM): 80 GPM MINIMUM PRESSURE: 90 PSI AVAILABLE PRESSURE: 125 PSI A IRRIGATION CONTROLLER PEDESTAL MOUNTED REQUIRES 120 VAC POWER 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2" 2" 2" 2" PRESSURE REDUCING MASTER VALVE: SET DISCHARGE PRESSURE TO 85 PSI 2.5" 2.5" 2" 2" 2" M F B 2.5" 2.5" 2.5" 2" MATCHLINE SEE SHEET IR-2.0 MA T C H L I N E S E E S H E E T I R - 2 . 1 MATCHLINE SEE SHEET IR-2.4 MATCHLINE SEE SHEET IR-2.5 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 2 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 4 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.2 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' V.P. A R V H2O TEST STA H Y D T 2.5" 2.5" 2.5" 2.5" 2.5" 2" 2" 2" 2" 2" 2" MATCHLINE SEE SHEET IR-2.1 MA T C H L I N E S E E S H E E T I R - 2 . 4 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 3 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 5 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.3 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' T T T T 2.5" 2.5" 2.5" 2" 2" 2" 2.5" 2.5" 2.5" 2.5" 2" 2" 2" MATCHLINE SEE SHEET IR-2.1 MATCHLINE SEE SHEET IR-2.2 MATCHLINE SEE SHEET IR-2.6 MA T C H L I N E S E E S H E E T I R - 2 . 3 MA T C H L I N E S E E S H E E T I R - 2 . 5 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 4 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 6 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.4 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" MATCHLINE SEE SHEET IR-2.6 MA T C H L I N E S E E S H E E T I R - 2 . 4 MATCHLINE SEE SHEET IR-2.2 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 5 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 0 7 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.5 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' TEST STA H Y D 2.5" 2.5" 2.5" 2.5" 2.5" MATCHLINE SEE SHEET IR-2.4 MATCHLINE SEE SHEET IR-2.5 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 2 . 6 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 2 5 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-2.6 FDP RD2 11/15/2023 01 02 IRRIGATION PLAN RAIN GARDEN SEED MIX - SPRINKLER IRRIGATED NATIVE SEED MIX - SPRINKLER IRRIGATED SHRUB - POINT SOURCE DRIP IRRIGATED DETENTION BASIN SEED - SPRINKLER IRRIGATED IRRIGATION HATCH LEGEND TURF - SPRINKLER IRRIGATED 0'20'10'40'120' 1"=20' NOTE: 1. FURNISH NOMINAL PIPE AND FITTING SIZES IDENTICAL WITH NOMINAL TAP SIZE UNLESS OTHERWISE NOTED. 2. THIS ASSEMBLY IS INTENDED TO BE USED FOR WINTERIZATION OF BACKFLOW PREVENTION ASSEMBLY ONLY. A B C D E F G H I J KLM A.12" STANDARD VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.1/4" THREADED BRASS CAP D.1/2" REDUCING MALE ADAPTER E.1/2" COPPER PIPE (LENGTH AS REQUIRED) F.6" PVC CL 200 PIPE (LENGTH AS REQUIRED) G.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL H.BRICK (1 OF 4) I.COPPER PIPE TO BACKFLOW PREVENTION ASSEMBLY (LENGTH AS REQUIRED) J.COPPER TEE K.COPPER MALE ADAPTER (1 OF 2) L.CURB STOP VALVE WITH COPPER SERVICE, THREAD BOTH ENDS M.COPPER PIPE TO EXISTING COPPER PIPE OUTSIDE EXISTING WATER METER NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 5. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID. 6. INSTALL SO THAT NO GRAVEL IS IN CONTACT WITH VALVE ASSEMBLY. A B C D E F G H I JK L A.TRACING WIRE B.FINISH GRADE/TOP OF MULCH C.STANDARD RECTANGULAR VALVE BOX W/ EXTENSION D.WIRE SPLICE, TYPICAL E.DECODER F.SOLENOID VALVE G.TWO-WIRE CABLE H.PVC MAINLINE I.BRICK (1 OF 4) J.FILTER FABRIC K.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL L.PVC SCH 40 MALE ADAPTER L NOTE: 1. FURNISH FITTINGS AND PIPING SIZED IDENTICALLY WITH NOMINAL BACKFLOW PREVENTION DEVICE. A B C D E F G H I J K A.BACKFLOW PREVENTER ENCLOSURE (SIZE AS NECESSARY) B.BACKFLOW PREVENTION DEVICE C.C x M COPPER ADAPTER (1 OF 2) D.TYPE K COPPER PIPE (TYPICAL) (LENGTH AS REQUIRED) E.CL200 PVC PIPE SLEEVE (1 OF 2) F.4" THICK CONCRETE PAD 6" LARGER IN ALL DIMENSIONS THAN ENCLOSURE G.FINISH GRADE/TOP OF MULCH H.COPPER FEMALE ADAPTER I.SCH 40 PVC MALE ADAPTER J.PVC MAINLINE K.TYPE K COPPER PIPE A B C D E F G H I J K A.TRACING WIRE B.12" VALVE BOX WITH COVER C.FINISH GRADE/TOP OF MULCH D.SENSOR DECODER E.WIRE SLICE, TYPICAL F.FLOW SENSOR G.TWO WIRE CABLE H.FILTER FABRIC I.PVC PIPE J.BRICK (1 OF 4) K.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL NOTES: 1. ALLOW 10 PIPE DIAMETERS UPSTREAM AND 5 PIPE DIAMETERS DOWNSTREAM OF STRAIGHT RUN OF PIPE TO ACHIEVE PROPER FLOW REGIME. 2. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 3. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 4. INSTALL SO THAT GRAVEL IS ONLY IN CONTACT WITH BOTTOM OF SENSOR ASSEMBLY. 1 WINTERIZATION ASSEMBLY N.T.S.2 BACKFLOW ASSEMBLY N.T.S. 5 MASTER VALVE ASSEMBLY N.T.S. 6 FLOW SENSOR ASSEMBLY N.T.S. NOTE: 1. NOMINAL SIZE OF GATE VALVE TO MATCH NOMINAL MAINLINE SIZE. A B C D E F G H I A.FINISH GRADE/TOP OF MULCH B.10" ROUND VALVE BOX WITH COVER C.6" PVC CL 200 PIPE (LENGTH AS REQUIRED) D.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL E.BRICK (1 OF 2) F.THREADED BRONZE GATE VALVE WITH SOLID WEDGE, NON-RISING STEM G.PVC MAINLINE H.PVC SCH 40 MALE ADAPTER (1 OF 2) I.TRACING WIRE 3 ISOLATION GATE VALVE-THREADED ASSEMBLY (2.5" AND SMALLER)N.T.S. 4 ISOLATION GATE VALVE-PUSH-ON ASSEMBLY (3" AND LARGER)(N.T.S.DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 3 . 0 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 3 7 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-3.0 FDP RD2 11/15/2023 01 02 M F IRRIGATION DETAILS NOTES: 1. USE VALVE BOX EXTENSION AS NECESSARY TO ACHIEVE MINIMUM DIMENSIONS ABOVE ASSEMBLY. 2. NOMINAL SIZE OF ALL COMPONENTS ARE TO BE THE SAME NOMINAL SIZE AS THE SOLENOID VALVE (SIZED AS SHOWN). 3. INSTALL FILTER FABRIC AROUND EXTERIOR OF VALVE BOX. USE DUCT TAPE TO SECURE FABRIC TO PIPE AND VALVE BOX. 4. TRANSITION TO PROPER LATERAL PIPE BURIAL DEPTH USING 45° ELBOW FITTINGS DOWNSTREAM OF REMOTE CONTROL VALVE ASSEMBLY. 5. DO NOT CUT OUT ENDS OF VALVE BOX UNNECESSARILY. 6. POSITION VALVE BOX OVER VALVE TO ALLOW ACCESS TO SOLENOID AND PROPER OPERATION OF BALL VALVE. 7. COIL 3-FEET OF TWO WIRE CABLE WITHIN VALVE BOX FOR SERVICE PURPOSES. S C DF G I K L M N O P Q R S B AE J H A.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS B.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL C.PVC BALL VALVE D.REMOTE CONTROL VALVE (INCLUDES DECODER) E.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED, HIDDEN) AND PVC SCH 40 EL F.CHRISTY ID TAG G.FINISH GRADE H.PVC SCH 80 CLOSE NIPPLE I.WIRE CONNECTOR FROM DECODER TO TWO WIRE CABLE J.PVC SCH 80 MALE ADAPTER K.12" STANDARD VALVE BOX WITH COVER L.PVC LATERAL PIPE M.FILTER FABRIC N.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED) O.PVC SCH 80 EL P.PVC SCH 80 PIPE (LENGTH AS REQUIRED) Q.BRICK (1 OF 4) R.PVC MAINLINE S.TWO-WIRE CABLE 4 REMOTE CONTROL VALVE ASSEMBLY N.T.S. NOTE: 1. FURNISH NOMINAL PIPE AND FITTING SIZES IDENTICAL WITH NOMINAL TAP SIZE UNLESS OTHERWISE NOTED. A B C D E F G H I J KLK A.12" STANDARD VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.1" BRONZE BALL VALVE FEMALE THREADED ENDS D.1" COPPER MALE ADAPTER E.1" COPPER PIPE (LENGTH AS REQUIRED) F.3" MIN. DEPTH OF 3/4" WASHED GRAVEL G.BRICK (1 OF 4) H.COPPER FEMALE THREADED ADAPTER I.SCH. 40 PVC MALE THREADED ADAPTER J.PVC MAINLINE K.COPPER PIPE L.COPPER TEE H I J 1 BLOW OUT ASSEMBLY N.T.S. A B C D E F G H I A.FINISH GRADE/TOP OF MULCH B.QUICK-COUPLING VALVE C.10" ROUND VALVE BOX WITH COVER D.HARCO QUICK COUPLER ANCHOR E.PVC SCH 80 TOE NIPPLE (LENGTH AS REQUIRED) F.BRICK (1 OF 2) G.PRE-FABRICATED UNITIZED SWING JOINT 1" MIPT INLET X SOC OUTLET H.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS I.PVC MAINLINE PIPE J.TRACING WIRE NOTES: 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 2. INSTALLATION HEIGHT OF QUICK COUPLER VALVE IN VALVE BOX MUST ASSURE PROPER OPERATION OF QUICK COUPLER KEY. 3. INSTALL SWING JOINT LAY ARM BETWEEN 30° AND 45° OF LATERAL PIPE IN ORDER TO ABSORB DOWNWARD IMPACT. J 2 QUICK COUPLING VALVE ASSEMBLY N.T.S. A B C D E F G H I J A.JUMBO VALVE BOX WITH EXTENSION AND COVER (HEIGHT AS REQUIRED) B.FINISH GRADE/TOP OF MULCH C.AIR VACUUM RELIEF VALVE D.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) E.PVC SCH 40 BALL VALVE (SIZE 1") F.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) G.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL H.BRICK (1 OF 4) I.PVC MAINLINE PIPE J.TEE OR EL: SEE SPECIFICATIONS FOR MATERIALS K.TRACING WIRE NOTES: 1. OPEN BALL VALVE IN ASSEMBLY 1/4 TURN UNTIL IRRIGATION SYSTEM IS FULLY CHARGED WITH WATER. 2. CLOSE VALVE DURING WINTERIZATION AND OPEN 1/2 TURN AFTER WINTERIZATION OF SYSTEM TO PROTECT VALVE DURING FREEZING WEATHER. 3. REPLACE PVC BALL VALVE WITH BRASS BALL VALVE IN THE EVENT AN AIR VACUUM RELIEF VALVE WITH MALE INLET IS USED. K 3 AIR VACCUM RELIEF VALVE ASSEMBLY N.T.S. A B C D E F A.FINISH GRADE/TOP OF MULCH B.POP-UP SPRAY SPRINKLER C.SWING PIPE, 12" LENGTH D.1/2" MALE NPT x BARB EL E.PVC SCH 40 TEE OR EL F.PVC LATERAL PIPE D 5 POP-UP SPRAY SPRINKLER ASSEMBLY N.T.S. SEE NOTE #1 NOTE: 1. INSTALL SWING JOINT LAY ARM BETWEEN 30° AND 45° OF LATERAL PIPE TO ABSORB DOWNWARD IMPACT. A B C D E A.FINISH GRADE B.POP-UP ROTOR SPRINKLER C.PRE-FABRICATED PVC SWING JOINT MIPT INLET x MIPT OUTLET D.PVC LATERAL PIPE E.PVC SCH 40 TEE OR EL 6 POP-UP ROTOR SPRINKLER ASSEMBLY N.T.S. DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 3 . 1 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 3 7 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-3.1 FDP RD2 11/15/2023 01 02 B Q IRRIGATION DETAILS ROOT BALL A B C D E F G H I A.WATER BASIN B.STREAM BUBBLER C.FINISH GRADE D.POP-UP SPRAY SPRINKLER W/ BUBBLER E.1/2" MALE NPT x 0.490" BARB EL F.SWING PIPE, 12" LENGTH G.1/2" MALE NPT x 0.49" BARB EL H.PVC LATERAL PIPE I.PVC SCH. 40 TEE OR EL 1 POP-UP BUBBLER ASSEMBLY N.T.S. A B C D E F G H I J K L M N O A.6" ROUND VALVE BOX WITH COVER B.FINISH GRADE/TOP OF MULCH C.PVC SCH. 40 EL D.PVC BALL VALVE E.PVC SCH. 40 TRANSITION NIPPLE (MIPTxMHT) F.COMPRESSIONxFEMALE HOSE SWIVEL ADAPTER G.DRIP LATERAL PIPING H.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL I.BRICK (1 OF 2) J.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED, 1 OF 2) K.PVC SCH 40 EL L.PVC SCH 40 STREET EL (1 OF 2) M.PVC DRIP MANIFOLD PIPE N.PVC SCH 40 TEE OR EL O.PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) 2 ZONE CONTROL VALVE ASSEMBLY N.T.S. X X X X X X X X X X X X X X X X X X X X X X X X NOTES: 1. EMITTERS SHALL BE LOCATED IMMEDIATELY ADJACENT TO PERENNIALS AND AT THE OUTSIDE PERIMETER OF THE PLANTING PIT OF ALL SHRUBS AND TREES. 2. INSTALL FOUR 1 GPH EMITTERS PER DECIDUOUS TREE. 3. INSTALL THREE 1 GPH EMITTER PER CONIFEROUS TREE. 4. INSTALL TWO 1 GPH EMITTER PER SHRUB. 5. INSTALL ONE 1 GPH EMITTER PER PERENNIAL. A B C D E F A.DRIP LATERAL PIPE B.CONIFEROUS TREE C.DECIDUOUS TREE D.EMITTER E.SHRUB F.PERENNIAL 3 EMITTER PLACEMENT DETAIL N.T.S. NOTE: 1. INSTALL FLUSH CAP ASSEMBLY AT THE END OF EACH DRIP LATERAL SEGMENT. A B C D E F A.FINISH GRADE/TOP OF MULCH B.6" ROUND VALVE BOX WITH COVER C.FLUSH CAP WITH HOSE THREAD CAP D.DRIP IRRIGATION LATERAL E.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL F.BRICK (1 OF 2) 4 FLUSH CAP ASSEMBLY N.T.S.5 SLEEVING AND SIZING SCHEDULING ASSEMBLY N.T.S. SLEEVE SIZING SCHEDULE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 3 . 2 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 1 : 2 6 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-3.2 FDP RD2 11/15/2023 01 02 12" MINIMUM NOTE: 1. INSTALL SLEEVE SO THAT ITS LOWEST ELEVATION OCCURS AT ONE OR BOTH ENDS - NOT ALONG ITS LENGTH. A B C D A.FINISHED GRADE OF PAVED SURFACE B.SLEEVE FOR LATERAL PIPE C.SLEEVE FOR MAINLINE PIPE D.SLEEVE FOR WIRING 6 IRRIGATION CONTROLLER ASSEMBLY N.T.S. A C D E F GB A.IRRIGATION CONTROLLER ASSEMBLY B.1" SCH 40 ELECTRICAL CONDUIT AND SWEEP EL FOR ELECTRICAL SERVICE C.FINISH GRADE D.CONCRETE PAD (6" MINIMUM THICKNESS) E.COMPACTED SUBGRADE F.3" SCH 40 ELECTRICAL CONDUIT AND SWEEP EL FOR TWO WIRE CABLE G.1" SCH 40 ELECTRICAL CONDUIT AND SWEEP EL FOR ELECTRICAL GROUNDING H.RAIN SENSOR IN VIT RAIN SENSOR GUARD H IRRIGATION DETAILS A 5 DECODER GROUNDING SCHEMATIC N.T.S. A A.TWO-WIRE CABLE B.VALVE BOX (10" ROUND OR AS NECESSARY) C.REMOTE CONTROL VALVE D.5/8" X 8' U.L. LISTED GROUND ROD E.DECODER F.LINE SURGE PROTECTOR G.BARE AWG #10 COPPER WIRE H.3M DBR/Y-6 CONNECTION I.BARE COPPER CONNECTION ("CADWELD") J.REMOTE CONTROL VALVE ASSEMBLY 500' MAX OR 5 DECODERS BETWEEN GROUND POINTS WHICHEVER IS FIRST GROUND ALL DEAD ENDS 25' AND LONGER SPHERE OF INFLUENCE WIRE PATH OUTSIDE SPHERE OF INFLUENCE (10' MIN.)GROUND TWO WIRE CABLE NEAR CONTROLLER PER MANUFACTURER'S GUIDELINES NOTES: 1. ALL WIRE CONNECTION SHALL BE MADE WITH APPROVED CONNECTORS. 2. MAKE ALL WIRE SPLICES IN VALVE BOXES. 3. LEAVE A MINIMUM OF 5' EXTRA WIRE AT ALL SPLICE POINTS. 4. TEST EARTH TO GROUND RESISTANCE AT ALL GROUND POINTS. 5. EARTH TO GROUND RESISTANCE MUST MEET OR EXCEED MANUFACTURER REQUIREMENTS. 6. INSTALL ALL GROUND ASSEMBLIES IN VALVE BOXES. 7. INSTALL GROUNDING EQUIPMENT AS INDICATED ON THE IRRIGATION DOCUMENTS AND AS RECOMMENDED BY THE MANUFACTURER. C D A JB E G H F I B 4 WIRESPLICE ASSEMBLY N.T.S. 1. 2. 3.4. 1/2" 5. NOTE: 1. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS". 1. STRIP ENDS OF WIRE 2. SECURE WIRES INTO WIRE NUT 3. INSERT WIRE NUT INTO GEL-FILLED TUBE 4. POSITION WIRES INTO CHANNELS 5. CLOSE SPLICE KIT FOR SECURED SEAL FINISHED GRADE ELEVATION VIEW PLAN VIEWNOTES: 1. COPPER TRACING WIRE WILL START AT THE MASTER VALVE AND WILL BE ROUTED WITH ALL MAINLINE PIPE. 2. SPLICE TRACING WIRE IN IRRIGATION MAINLINE COMPONENT VALVE BOXES WHEN POSSIBLE, OTHERWISE, PLACE SPLICE IN SEPARATE VALVE BOX. A B C D E F G H A.10" ROUND VALVE BOX B.INSTALL TRACING WIRE TO THE TOP OF VALVE BOX C.WATER PROOF CONNECTION (SEE SPECIFICATIONS) D.PIPE SLEEVE SEE VALVE DETAIL E.TAPE COPPER WIRE TO TOP OF PIPE EVERY 10 FT. F.CONTINUOUS LOOP COPPER TRACING WIRE (SEE SPECIFICATIONS) G.PVC PIPE H.VALVE (TYPICAL) 3 TRACING WIRE ASSEMBLY N.T.S.1 IRRIGATION CONTROLLER GROUNDING DETAIL N.T.S. PLAN VIEW A.IRRIGATION CONTROLLER ASSEMBLY B.UL LISTED 5/8" X 10' COPPER-CLAD GROUNDING ROD C.UL LISTED 4" X 8' COPPER GROUNDING PLATE D.10" ROUND VALVE BOX WITH COVER E.BRONZE GROUND ROD CLAMP OR CADWELD CONNECTION: PAIGE ELECTRIC F.3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL G.BRICK (1 OF 4) H.#6 AWG INSULATED SOLID COPPER WIRE. NO SHARP BENDS. I.SPHERE OF INFLUENCE J.EARTH CONTACT MATERIAL, POWERSET© OR POWERFILL© DEPENDING ON SOIL CONDITIONS K.FINISH GRADE A C B 8' 10' 11' I I 30" MINIMUM 12" SECTION VIEW H H H B C J D G F E NOTES: 1.CONNECT ALL #6 AWG WIRES INSIDE THE CONTROLLER. CONNECT ONE WIRE TO THE CONTROLLER GROUND LUG AND USE A #4 SPLIT BOLT TO CONNECT ALL WIRES TOGETHER. 2.EARTH CONTACT MATERIAL MUST COMPLETELY COVER THE WELD JOINT ON THE GROUND PLATE. K A B C D E F G A.WARNING TAPE B.FINISH GRADE C.BACKFILL D.LATERAL/MANIFOLD PIPE E.TWO-WIRE CABLE F.MAINLINE PIPE G.TRACING WIRE REFER TO SPECIFICATIONS REFER TO SPECIFICATIONS 2 TRENCH DETAIL N.T.S. DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 3 . 3 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 3 7 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-3.3 FDP RD2 11/15/2023 01 02 IRRIGATION DETAILS DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Pl o t t e d B y : Ja s o n H . K l a u s n e r La y o u t : IR - 3 . 4 Pr i n t e d O n : 11 / 1 0 / 2 0 2 3 1 0 : 3 7 A M Fi l e N a m e : P- L E M A Y L A M D - M F . d w g ORIGINAL SIZE 24X36 ENT I T L E M E N T DRA W I N G S NOT F O R CON S T R U C T I O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com FDP RD1 09/27/2023 THE LANDING AT LEMAY FDP SUBMITTAL FORT COLLINS, CO PLANNER/ LANDSCAPE ARCHITECT OWNER/ APPLICANT ARCHITECT ENGINEER JMA/JHK JHK IR-3.4 FDP RD2 11/15/2023 01 02 1 HYDRAULIC ESTIMATION 2 IRRIGATION CONTROLLER PEAK IRRIGATION SCHEDULE NOTES: 1. THE PEAK SEASON RUN TIME HAS BEEN CALCULATED ASSUMING AN IRRIGATION EFFICIENCY OF 70% AND A PEAK SEASON ETo OF 0.21 INCHES/DAY. THE CROP COEFFICIENT IS ASSUMED TO BE 0.8 FOR TURF. 2. THE POC SIZE WAS CALCULATED FOR A 8 HR X 6 DAYS/WEEK IRRIGATION WINDOW TO IRRIGATE THE TURF GRASS AND SEED. 3. ADJUST INDIVIDUAL STATION RUN TIMES AS NECESSARY TO ACCOMMODATE TURF/PLANT ESTABLISHMENT, TURF TYPE, TURF/PLANT SOLAR EXPOSURE, SOIL TYPES, WIND, AND SLOPE. 4. ADJUST DRIP RUN TIMES AS NECESSARY FOR PLANT ESTABLISHMENT. RECORD RUN TIMES ON THE RECORD DRAWINGS. 5. BLANK ITEMS TO BE COMPLETED ON AS-BUILT DRAWINGS BY CONTRACTOR. SOIL TYPE - CLAY, SAND, LOAM, ETC. SLOPE - NONE, GENTLE, MILD, STEEP. MICROCLIMATE - SHADE, PARTIAL SUN/SHADE, FULL SUN. 6. PROVIDE LAMINATED COPY OF PEAK IRRIGATION SCHEDULE WITHIN IRRIGATION CONTROLLER ENCLOSURE. IRRIGATION DETAILS