September 1, 2017
Steve Schroyer
NORTH SPRING CREEK PROPERTIES, LLC
401 WEST MOUNTAIN AVENUE
Fort Collins, CO 80521
RE: Spring Creek Mixed Use Development, REZ170001, Round Number 1
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com.
Comment Summarv:
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcqov.com
Topic: General
Comment Number: 1
•
Comment Originated: 08/29/2017
08/29/2017: The rezoning map that has been prepared appears to be
establishing zoning boundaries based on a centerline of a future Stuart Street
would have a concern if this sets up an expectation of the future street design
needing to follow zoning line that is established. The conceptual street design
may not meet horizontal curve geometry requirements for the street
classification.
Department: Environmental Planning
Contact: Rebecca Everette, 970-416-2625, reverette@fcgov.com
Topic: General
Comment Number: 1
Comment Originated: 08/22/2017
08/22/2017: Environmental Planning staff does not have concerns about the
rezone. However, please note that the concept plan included in the submittal
shows encroachments into the Spring Creek buffer and does not necessarily
comply with the standards in section 3.4.1 of the Land Use Code.
Environmental protection requirements will be applied once a PDP has been
submitted.
• •
Comment Number: 2 Comment Originated: 08/22/2017
08/22/2017: Note that much of this site will not be developable as it is located
within the Spring Creek buffer. This may be a consideration factor for both the
Planning & Zoning Board and City Council.
Department: Light And Power
Contact: Clint Reetz, 970-221-6326, creetz@fcqov.com
Topic: General
Comment Number: 1
Comment Originated: 08/29/2017
08/29/2017: Light and Power can serve this location. Existing electric facilities
are located along Shields St and on the North side of Hobbit St.
Comment Number: 2 Comment Originated: 08/29/2017
08/29/2017: Development charges, electric Capacity Fee, Building Site
charges and any system modification charges necessary will apply to this
development.
Comment Number: 3
Comment Originated: 08/29/2017
08/29/2017: You may contact FCU Light & Power, project engineering if you
have questions. (970) 221-6700. You may reference Light & Power's Electric
Service Standards at
http://www.fcgov.com/utilities/img/site_specific/uploads/ElectricServiceStandar
ds_FI NAL_18November2016_Amendment. pdf
You may reference our policies, development charge processes, and use our �
fee estimator at
http://www.fcgov.com/utilities/business/builders-and-developers.
Department: PFA
Contact: Cal Sheesley, 970-416-2599, csheeslev@poudre-fire.org
Topic: General
Comment Number: 1
08/29/2017: NO COMMENT PER REZONE
Comment Originated: 08/29l2017
Poudre Fire Authority has no comment specific to the rezone. Below are
general fire department requirements for future development of the property.
Comment Number: 2 Comment Originated: 08/29/2017
08/29/2017: FIRE LANES
Fire access is required to within 150' of all exterior portions of any buildings as
measured by an approved route around the perimeter. For the purposes of this
section, fire access cannot be measured from an arterial road (Shields).
Roadways internal to the site shall serve as the fire lanes and meet the
requirements provided in comment #3.
Code language follows:
2
> IFC 503.1.1: Ap•ved fire Lanes shall be provided for every facility, building
or portion of a building hereafter constructed or moved into or within the
jurisdiction. The fire apparatus access road shall comply with the requirements
of this section and shall extend to within 150 feet of all portions of the facility and
all portions of the exterior walls of the first story of the building as measured by
an approved route around the exterior of the building or facility. When any
portion of the facility or any portion of an exterior wall of the first story of the
building is located more than 150 feet from fire apparatus access, the fire code
official is authorized to increase the dimension if the building is equipped
throughout with an approved, automatic fire-sprinkler system.
Comment Number: 3
08/29/2017: FIRE LANE SPECIFICATIONS
Comment Originated: 08/29/2017
A fire lane plan shall be submitted for approval prior to installation. In addition to
the design criteria already contained in relevant standards and policies, any
new fire lane must meet the following general requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum
overhead clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting
40 tons.
> Dead-end roads shall not exceed 660' in length without providing for a second
point of access.
> Dead-end fire access roads in excess of 150 feet in length shall be provided
with an approved area for turning around fire apparatus.
> The required turning radii of a fire apparatus access road shall be a minimum
of 25 feet inside and 50 feet outside. Turning radii shall be detailed on
submitted plans.
> Be visible by painting and/or signage, and maintained unobstructed at all
times. Sign locations or red curbing should be labeled and detailed on final
plans.
*STRUCTURES EXCEEDING 30' IN HEIGHT'
> IFC Appendix D; Poudre Fire Authority Administrative Policy 85-5: In order to
accommodate the access requirements for aerial fire apparatus (ladder trucks),
required fire lanes shall be 26 foot wide minimum on at least one long side of
the building. At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the
building, and shall be positioned parallel to one entire side of the building.
Comment Number: 4
Comment Originated: 08/29/2017
08/29/2017: WATER SUPPLY
Hydrant spacing and flow must meet minimum requirements based on type of
occupancy. A hydrant is required within 300' of any Commercial Building
(multifamily is considered commercial) as measured along an approved path of
vehicle travel. An exception to this rule pertains to buildings equipped with a
standpipe system which require a hydrant within 100' of any Fire Department
Connection (FDC). Hydrants on the opposite sides of major arterial roadways
(Shields) are not considered accessible.
3
�
u
*COMMERCIAL REQUIREMENTS*
> IFC 507.5 and PFA Policy: Hydrants to provide 1,500 gpm at 20 psi residual
pressure, spaced not further than 300 feet to the building, on 600-foot centers
thereafter (EXCEPTION: In buildings equipped with standpipe systems, a
hydrant is required within 100' of the Fire Department Connection).
Comment Number: 5 Comment Originated: 08/29/2017
08/29/2017: PREMISE IDENTIFICATION: ADDRESS POSTING &
WAYFINDING
Addresses shall be posted on each structure and where otherwise needed to
aid in wayfinding.
Code language follows:
> IFC 505.1: New and existing buildings shall have approved address numbers,
building numbers or approved building identification placed in a position that is
plainly legible, visible from the street or road fronting the property, and posted
with a minimum of six-inch numerals on a contrasting background. Where
access is by means of a private road and the building cannot be viewed from
the public way, a monument, pole or other sign or means shall be used to
identify the structure.
Comment Number: 6 Comment Originated: 08/29/2017
08/29/2017: FIRE CONTAINMENT vs. AUTOMATIC SPRINKLRE SYSTEM
Buildings exceeding 5,000 square feet shall be sprinklered or fire contained.
>If containment is used, the containment construction shall be reviewed and
approved by the Poudre Fire Authority prior to installation.
>If Automatic Sprinkler System is used, contact Assistant Fire Marshal Joe
Jaramillo with questions at 970.416.2868.
Comment Number: 7
Comment Originated: 08/29/2017
08/29/2017: FIRE STANDPIPE SYSTEM
> IFC Sections 905 and 913: Standpipe systems shall be provided in new
buildings and structures in accordance with Section 905 or the 2015
International Fire Code. Approved standpipe systems shall be installed
throughout buildings where the floor level of the highest story is located more
than 30 feet above the lowest level of fire department vehicle access. The
standpipe system shall be capable of supplying a minimum of 100 psi to the top
habitable floor. An approved fire pump may be required to achieve this
minimum pressure. Buildings equipped with standpipes are required to have a
hydrant within 100 feet of the Fire Department Connection.
Department: Planning Servi•
Contact: Ted Shepard, 970-221-6343, tshepard@fcqov.com
Topic: General
Comment Number: 1
08/30/2017: Minor comments are offered on the narrative.
Comment Number: 2
�
Comment Originated: 08/30/2017
Comment Originated: 08/30/2017
08/30/2017: As noted in the narrative, the request will be reviewed by the
criteria of Section 2.9.4(H). Please add a paragraph to the narrative that
explains the relationship between the rezone request and the concept plan and
the extent to which the concept plan helps inform the request.
Department: Stormwater Engineering
Contact: Mark Taylor, 970-416-2494, mtaylor@fcgov.com
Topic: Floodplain
Comment Number: 1
Comment Originated: 08/29/2017
08/29/2017: A portion of this property is in a FEMA and City-regulated
100-year floodplain. Please be aware that any development in the floodplain
must comply with the City's floodplain requirements which can be found in
Chapter 10 of City Code.
Comment Number: 2 Comment Originated: 08/29/2017
08/29/2017: Critical Facilities, as described in Chapter 10 of City Code are not
allowed in a floodplain.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcqov.com
Topic: Site Plan
Comment Number: 1 Comment Originated: 08/28/2017
08/28/2017: The Zoning designations are confusing. See redlines.
Comment Number: 2 Comment Originated: 08/28/2017
08/28/2017: The legal descriptions do not match the map. See redlines.
�