HomeMy WebLinkAboutASRROWHEAD COTTAGES - MJA/FDP - FDP160004 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTSCit of � � y . vrt �oll�n� February 19, 2016 RE: Arrowhead Cottages, FDP160004, Round Number 1 � u Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134-fax fcgov. com/developmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Spencer Branson, at 970-224-6086 or sbranson@fcgov.com. Comment Summarv: Department: Planning Services Contact: Spencer Branson, 970-224-6086, sbranson@fcgov.com Topic: Building Elevations Comment Number: 7 Comment Originated: 02/16/2016 02/16/2016: Consider adding brick lintels over windows on stucco walls. Res�onse: The intent of the design is �o closely match the adjacent existing condo bui'-1'�g exterior finishes and materials. Aa��n�� b� ic�; '�.irte:s ti�����i!�� create a�iscontin,_ious �lestn�tic a.s t;ie existing bui!ding has stucco lintels. Comment Number: 8 Comment Originated: 02/16/2016 02/16/2016: Please provide a link to the manufactured stone called out on the elevations. Res�onse: Ti��� manuf�c���reci st�ne ��,i[I ���at�h, as closely Gs possib!e, the �.djacent existi�ng con�� stone. Topic: General Comment Number: 10 Comment Originated: 02/16/2016 02/16/2016: Plans need to be updated with current standard notes. I will email them to you. Response: Plans have been u,�dated v�ith neU�� sia.nda.rd notes. Topic: Landscape Plans Comment Number: 1 Comment Originated: 02/16/2016 02/1612016: Consider adding additional trees to the common space between the buildings. �i�S�?On��: �'�C�C�iI`.IOr�'i� 0�"fl�;fll��l�a� a"1C� S11'c1Gl,'-; �i�"� �� �iaV2 iJ�2�l "cldCac� Ifl COiI'llTlOi� S�aC?. Comment Num� 2 �mment Originated: 02/16/2016 02/16/2016: Consider replacing the Thin Leaf Alder with a more appropriate species for this site. Response: Thi,� Leaf Alder has been removed from the plans. Comment Number: 3 Comment Originated: 02/16/2016 02/16/2016: The proposed landscape plan does not meet the minimum standard for full tree stocking. Additional perimeter tree stocking is needed along Centre Avenue and Worthington Circle. Trees can be planted in a row or more informal arrangement, whichever is more appropriate for the utilities. Shade trees should be used whenever possible. Respo�se: Additional trees have been added along Centre Avenue and Worthington Circle. Topic: Lighting Plan Comment Number: 9 Comment Originated: 02/16/2016 02/16/2016: All exterior lighting shall be full cut off down directional. Response: Lighting plan5 ha��re k�aerR adjusted per above commen�. Topic: Site Plan Comment Number: 4 Comment Originated: 02/16/2016 02/16/2016: The front entrances of the one story building should face the street and have connecting walkways to the street sidewalk. Response: Connecting sidewalks have been added Update: I will have an answer regarding how the buildings address the public realm on Tuesday the 23rd. Comment Number: 5 Comment Originated: 02/16/2016 02/16/2016: Please indicate what the gross land area is that was used in the land-use statistics. Response: Gross land area boundary has been added and labeled. Comment Number: 6 Comment Originated: 02/16/2016 02/16/2016: This site is not in the TOD Overlay Zone. Please update the site plan to reflect the standard attached residential parking calculations. Respanse: Parking calculations have been adjusted to standard residential. Department: Engineering Development Review Contact: Katie Sexton, 970-221-6501, ksexton@fcqov.com Topic: General Comment Number: 1 Comment Originated: 02/16/2016: Please show public pedestrian ramps on plans. Response: Provided call-outs for existing pedestrian ramps on plans Comment Number: 2 Comment Originated: 02/16/2016: An offsite utility and construction easement will need to be obtained from the property owner to the east. A letter of intent from the property will need to be submitted before final plans can be approved. Response: Utility and Construction easements to be provided by separate document. Comment Number: 3 Comment Originated: 02/16/2016: There needs to be more discussion regarding the plat. Response: Acknowledged 02/16/2016 02/16/2016 02/16/2016 Comment Nu�: 4 �omment Originated: 02/16/2016 02/16/2016: All applicable items on Appendix E-4 will needs to be checked off before FDP is approved. Res�onse: AcKnowleda�d Comment Number: 5 Comment Originated: 02/16/2016 02/16/2016: What is the thick dashed line running easUwest just north of the garage/existing building? Include this in the legend. Response: Line removed f�om p!an� Department: Environmental Planning Contact: Kelly Kimple, 970-416-2401, kkimple@fcgov.com Topic: General Comment Number: 1 Comment Originated: 02/17/2016 02/17/2016: The mylars for Centre Ave Residences show a Natural Habitat Buffer Zone (NHBZ) between the development and the canal, with a standard buffer for irrigation ditches of 50'. The NHBZ needs to be delineated on the site, grading, utility, and landscape plans. And an Environmental Planner signature line needs to be added to all utility plans that show the buffer. Respo��se: NNBZ V��as been added and labeled on all plans, si��ar�at�.�re L':�c� ��,d�ad a� �,���e�l. Comment Number: 2 Comment Originated: 02/17/2016 02/17/2016: Please also add the following notes to any sheets that show the NHBZ: -Please see Section 3.4.1 of the Land Use Code for allowable uses within the buffer zone. -The NHBZ is meant to be maintained in a native landscape. These notes will help preserve the intention of the NHBZ and the natural features into the future. Response: Note has been added to both Lan�scape Sh�ets. Comment Number: 3 Comment Originated: 02/17/2016 02/17/2016: It appears that most of the landscaping within NHBZ had been postponed until Phase II of this project. This landscaping should be installed as part of the major amendment. Please update the landscaping plans in the NHBZ to show existing vegetation and proposed plantings. Within the natural habitat buffer zone, according to Article 3.4.1(E)(1)(g), the City has the ability to determine if the existing landscaping within the buffer zone is incompatible with the purposes of the buffer zone. R��;�onse: La°��c�scape in fJ�BZ i� already instalied per a�proved Minor Ammendment Phase 1 Pians. Comment Number: 4 Comment Originated: 02/17/2016 02/17/2016: Thank you for providing a photometric plan with this PDP submittal. Current plans do not appear to show light spillage into the delineated 50' natural habitat buffer zone; however, the photometric plan does not accurately label the NHBZ. Please update to show the NHBZ line as on the site, landscape and utility plans. With respect to lighting, the City of Fort Collins Land Use Code, in Article 3.2.4(D)(6) requires that "natural areas and natural features shall be protected from light spillage from off-site sources." Thus, lighting from the buildings or other site amenities shall not spill over to the buffer areas. In regard to LED light fixtures, cooler color temperatures are harsher at night and cause more disruption to circadian rhythms for both humans and wildlife. Please c�er a warmer color temperature (3000K)1�our LED light fixtures. Please also consider fixtures with dimming capabilities so that light levels can be adjusted as needed. Respanse: Habitat buffer has been labeled. Fixtures have been addressed for warmer temperature. Comment Number: 5 Comment Originated: 02/17/2016 02/17/2016: A security will need to be collected for the installation and establishment of the Natural Habitat Buffer Zone, as per the approved plans and Development Agreement. Please note the developer typically provides an estimate of the landscaping costs for the Natural Habitat Buffer Zone, including materials, labor and irrigation. We then use the approved estimate to collect security at 125% of the total amount. Response: Security will be collecied at time of installation Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanan@fcgov.com Topic: General Comment Number: 1 02/08/2016: Comment Originated: 02/08/2016 Show the location of significant trees to be removed. These include the 7 Honeylocust in the plaza on the east side of the project. Label the trees by species, size and mitigation. The species and size are on the original approved plan. Diameter will need to be measured. Contact the City Forester if assistance is needed in measuring the diameter of these trees. Response: Plans have been updated with Honey Locust trees and size has been listed as below 6" And no mitigation required. Topic: Landscape Plans Comment Number: 2 02/08/2016: Comment Originated: 02/08/2016 There were 13 mitigation trees required on the original plan for tree removal which includes the mitigation for the 7 honeylocust. The mitigation for these tree removals has been met with current tree planting. Response: Acknowledged Comment Number: 3 02/08/2016: Add this tree protection note: Comment Originated: 02/08/2016 All existing trees with the exception of 7 honeylocust shown to be removed shall be kept in place and protected. Response: Note has been added Comment Number: 4 02/08/2016: Comment Originated: 02/08/2016 There are less trees being provided with the Major Amendment than on the original approved plan. The following are generally where there is a difference. Evaluate these zones and any others where fewer trees are provided and determine where it is feasible to add additional trees. South of 3 unit building West side of 3 unit building SE of 3 unit buii�j � 1 shade tree south of the project entrance off Worthington Circle — none shown North of 3 unit building SW side of the 6 unit building Generally along the east border of the project F'ses�onse: Trees have be�n �dc�e�l where appropria�e to bri:�g to�al count up and soften commo;� are��s Comment Number: 5 02/08/2016: Comment Originated; 02/08/2016 The widths of the existing parkways are substandard so tree planting behind the walk is appropriate. �esponse: Acknotivledged Comment Number: 6 02/08/2016: Comment Originated: 02/08/2016 List trees in the plant list by caliper and B&B. Minimum caliper or heights are as follows: Canopy shade trees: 2.0 inch caliper Ornamental trees 1.5 inch caliper Evergreen trees 8 feet height Respor�se: All required info is listed in tf�� plant list on Sh��ct 2 of Landscape Plan Comment Number: 7 02/08/2016: Comment Originated: 02/08/2016 Thinleaf alder is not a shade tree but is listed in that category. The location where it is proposed on the plan appears that it should be a shade tree. Review for making this a shade tree at this location and select an appropriate species. Response: Thir� leaf alder has bee�� removed from the landscape pians. Comment Number: 8 02/08/2016: Comment Originated: 02/08/2016 Prairie Fire Crabapple is listed to have some susceptibility to the disease fire blight in the Front Range Tree Recommendation List. Consider using another cultivar with better disease resistance such as Thunderchild Crabapple. Response: Thun�erchild Crabapple has replaced Prai; ie Fir� Comment Number: 9 02/08/2016: Comment Originated: 02/08/2016 Use the new City of Fort Collins General Landscape notes and Tree Protection Notes on the Plan. These notes are available from the City Planner assigned to the project or from the City Forester. Response: Updated I�n�s��;�c �otes have b�en added ta Landscape Plans Department: Internal Services Contact: Sarah Carter, 970-416-2748, scarter@fcgov.com Topic: Building Insp Plan Review Comment Number: 1 Comment Originated: 02/16/2016 02/16/2016: Please schedule a pre-submittal meeting for this project. Pre-Submittal meetings assist the designer/builder by assuring, early on in the design, that the new commercial or multi-family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid-design stage for this meeting to be effective. App�ts of new commercial or multi-family proj� should email scarter@fcgov.com to schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Respo�se: Pre submittal meeting will be scheduled. Comment Number: 2 Comment Originated: 02/16/2016 02/16/2016: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com/building web page to view them. Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter. Contact: Spencer Branson, , sbranson@fcgov.com Topic: General Comment Number: 3 Comment Originated: 02/17/2016 02/17/2016: Projects with three or more tenant units require the Unit Level Addressing form to be completed and submitted to the GIS Department after plans have met final approval through Development Review and are recorded with the City. This can occur anytime during construction, but before any utilities or address signs are installed. All addressing will be determined by the GIS Department and submitted to Poudre Fire Authority, USPS, Building Services, and Fort Collins Utilities. Failure to contact GIS and determining addresses through other means may result in address changes. The Unit Level Addressing form can be obtained by contacting the GIS office after the plans are recorded at gis@fcgov.com or (970) 416-2483. R�sy�orise: Proper forms ����ill be complet2d if necessary Department: Light And Power Contact: Tyler Siegmund, 970-416-2772, tsiegmund@fcqov.com Topic: General Comment Num�: 1 �omment Originated: 02/17/2016 02/17/2016: Light and Power has electric facilities along Worthington Circle, southeast of the existing drive, that can be utilized to provide power. Is it anticipated that single or three phase power will be needed? Res;�onse: Meeiir�g wi:l be scheci�.ilecl, power will be addresseu. Comment Number: 2 Comment Originated: 02/17/2016 02/17/2016: Electric capacity fees, development fees, building site charges and any system modification charges necessary will apply to this development. Please visit the below link to utilize our fee estimator to get an estimate of electric fees for this project. Please contact me for any questions regarding electrical development fees. http://www.fcgov.com/utilities/business/builders-and-developers/plant-investmen t-development-fees Response: Any fees will be submi�;e�i Comment Number: 3 Comment Originated: 02/17/2016 02/17/2016: The transformer location will need to be coordinated with Light & Power. The transformer must be placed within 10 ft of a drivable surface for installation and maintenance purposes. The transformer must also have a front clearance of 10 ft and side/rear clearance of 3 ft minimum. Please show and label the transformer location(s) on the site plan, landscape plan, and utility plan. Response: Item as beint� adcli��ssed, trar�sformers vuill be added Comment Number: 4 Comment Originated: 02/17/2016 02/17/2016: Meter locations will need to be coordinated with Light and Power Engineering. Each unit will need to be metered individually. Please gang the meters on one side of the building, opposite of the gas meters. Please show and label the electric meters on the site/landscape plans and utility plans. Response: Meter locations will be coordinated and shown on plans Comment Number: 5 Comment Originated: 02/17/2016 02/17/2016: Please provide a one line diagram and a Commercial Service (C-1) Form to Light and Power Engineering. The C-1 form can be found at: http://zeus.fcgov.com/utils-procedures/files/EnqWiki/WikiPdfs/C/C-1 Form.pdf Respor�se: Diagram will be complete� Comment Number: 6 Comment Originated 02/17/2016: Light & Power will need the following documentation to be submitted before design will begin and construction release for the project: AutoCAD files of the approved Site Plan, Plat, Landscape Plan, and Utility Plans. Please send to tsiegmund@fcgov.com once plans are approved. Response: Required documentation will be submitted prior to construction release. Department: Outside Agencies Contact: Spencer Branson, , sbranson@fcqov.com Topic: General 02/17/2016 Comment Number: 2 Comment Originated: 02/16/2016 02/16/2016: Comments from Dan Kapperman (970-567-0245) at Comcast: Can plat be spel�ut as a access + utility easement � Comcast facility needs to be in a 6' utility easement to building Response: Changes have been made to plat Topic: Plat Comment Number: 1 Comment Originated: 02/16/2016 Comment from Megan Harrity (mharrity@larimer.orgj �vith Larimer C�urty Assessor: In 2012 this property was platted as Arrowhead Condominiums. The plat was recorded on 1/3/2012 at 20120000249. The land surrounding the platted ten condo units is GCE for the units of Arrowhead Condos. Typically a Supplemental Condo Map would be recorded for the development of future buildings, but this preliminary is not for condominiums. Will there be a document recorded to vacate the existing Arrowhead Condos? Response: A document 4vill be recorded if necessary Department: PFA Contact: Jim Lynxwiler, 970-416-2869, I�ynxwiler@poudre-fire.orq Topic: General Comment Number: 1 Comment Originated: 02/16/2016 02/16/2016: EMERGENCY ACCESS EASEMENT The limits of the EAE may be adjusted as per redline. Response: EAE adjusted per redlines Department: Stormwater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 02/10/2016 02/10/2016: Sheet G1: Grading Plan Please provide additional slope and spot elevation information. Response: SIop2 and spot el�;vation information 2dcie�c� Comment Number: 2 Comment Originated: 02/10/2016 02/10/2016: Sheet G1: Grading Plan Please provide the finished floor elevation for the detached garage. Response: Garage floar elevatio� information added Comment Number: 3 Comment Originated: 02/10/2016 02/10/2016: Sheet G1: Grading Plan There is a storm pipe shown along the northeasterly boundary of the site that is located within the neighboring property in two locations. Please note that you will need to procure and easement from the neighboring property owner if this is truly the pipe alignment you plan for. You will need to provide a letter of intent from that property owner prior to hearing that basically states that they understand your plans and will provide easement when the final design is complete. Response: Easement by separate document to be provi��ed and letter of intent to be issued prior to fi�al c�G���ic7?lC•2. • Comment Number: 4 • Comment Originated: 02/10/2016 02/10/2016: Sheet G1: Grading Plan This project was routed as an "FDP" but the plans are at a"preliminary" level, not "final". Please ciarify if the plans are supposed to be preliminary or final. Final level plans will require more detail and I can comment on final level detail in the next round if needed. Response: Submit'tal is preliminary, more info will be provided at finai. Comment Number: 5 Comment Originated: 02/10/2016 02/10/2016: Sheet G1: Grading Plan This project is considered a Major Amendment and as such is required to meet current Land Use Code requirements, which includes LID. It looks like the plans do include a bio-swale and some permeable pavement. Please also provide information in the plans and in the drainage report that shows how you're complying with the required LID percentage rates. Please note that the current LID requirements can be met in one of two ways: - 50% of the newly added or modified impervious area must be treated by LID techniques and 25% of new paved areas must be pervious. - 75% of all newly added or modified impervious area must be treated by LID techniques. Response: LID compliance le�fer provio��� Comment Number: 6 02/10/2016: Sheet G1: Grading Plan See redlines for other comments. Respo�se: Acknowledg�d Comment Number: 7 Comment Originated: 02/10/2016 Comment Originated: 02/10/2016 02/10/2016: Sheet D3: Drainage Details The bioswale detail does not meet the City requirements. Please replace this detail with City of Fort Collins Detail D-53. Res�ons�: Detail D-53 a����: �n p'.�-��. Topic: Drainage Report Comment Number: 8 Comment Originated: 02/10/2016 02/10/2016: The report states previously assumed imperviousness that was approved as part of the Centre Avenue Residences project, but I can't duplicate that number. Please provide an excerpt from that report and/or show how you obtained this number. Also, for this project the proposed imperviousness stated in the report doesn't seem to match what is provided in the Rational Method tables. Pes;�on��: Uqci�t=�ci i����,�2rvious �i�e��<s t��:� m�'c�� ��revic�us repo��t. Topic: General Comment Number: 9 Comment Originated: 02/10/2016 02/10/2016: Provide LID information and calculations. Also, provide an LID table on the Drainage Plan. An LID table typically provides information such as: impervious area, impervious area treated by each LID system, run-on ratios. Response: LID compliance letter provided Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com Topic: Erosion Control • • Comment Number: 10 Comment Originated: 02/16/2016: The site disturbs more than 10,000 sq-ft, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Current Erosion Control Materials Submitted and make reference to documents that were approved under prior criteria and do not meet current requirements. Please submit; Erosion Control Plan (based upon redlines), Erosion Control Report (references to old materials and placing SWMP responsibility on the contract is not in accordance with design criteria), and an Escrow / Security Calculation (will need to be recalculated to reflect the current scope of work) . If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcqov.com Response: Erosion Control M�ierials to be included with final submittal. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 14 Comment Originated 02/11/2016: Please remove "Centre Avenue Residences" from the title & titleblock, and add "Cottages" to "Arrowhead". See redlines. Response: Centre Avenue Residences has been removed from titles. Topic: Construction Drawings Comment Number: 16 02/16/2016 02/11 /2016 Comment Originated: 02/11/2016 02/11/2016: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX'. Response: Benchmark Statement added as sho�vn. Comment Number: 17 Comment Originated: 02/11/2016 02/11/2016: Why is the Basis Of Bearings not the same bearing & line as the Subdivision Plat? Response: Basis of bearing corrected Comment Num� 18 �mment Originated: 02/11/2016: All benchmark statements must match on all sheets. Resr�o�-�s�: Benchmark statements match on all sh�ets Comment Number: 19 Comment Originated: 02/11/2016: There are spelling issues with some text. See redlines. �esponse: Corrected spelling issue Comment Number: 20 Comment Originated: 02/11/2016 02/11/2016: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Fies�onse: Masked all text in hatched areas. Comment Number: 21 Comment Originated: 02/11/2016: There are line over text issues. See redlines. Response: Corrected line of text issues Comment Number: 22 Comment Originated: 02/11/2016: Please tie the coordinate values shown for utilities to the project boundary. We would prefer that this be done by adding property corner values to each sheet, or showing the property corner values on the horizontal control plans and adding a note to each sheet with coordinate values. �es}�orse: Ad���' p,,���-���;� cu���� � I_���-. _, � f������ r���i�o ���.I co�����ol r�=��. Topic: Landscape Plans Comment Number: 11 02/11 /2016 02/11 /2016 02/11 /2016 02/11 /2016 Comment Originated: 02/11/2016 02/11/2016: Please remove "Centre Avenue Residences" from the title & titleblock. See redlines. Res�:�onse: Centre Avenue Residences has been removed Comment Number: 12 Comment Originated: 02/11/2016 02/1112016: There are line over te� issues. See redlines. Response: Line over text issues have bee� addressed Comment Number: 13 Comment Originated: 02/11/2016 02/11/2016: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response: Texi i�:::� ;�. _�� __� .._i Topic: Lighting Plan Comment Number: 15 Comment Originated: 02/11/2016 02/11/2016: Please remove "Centre Avenue Residences" from the title & titleblock, and add "Cottages" to "Arrowhead". See redlines. Response: Title block has been updated Topic: Plat Comment Number: 1 Comment Originated: 02/11/2016 02/11/2016: Please add new title commitment information as available. . Response: No title Comrr�itment provideci to the surveyor. Title commitment note revised. Comment Number: 2 02/11/2016: Please add floodplain information. Respor�se: Floodplain note added. Comment Originated: 02/11/2016 Comment Number: 3 Comment Originated: 02/11/2016 02/11/2016: Please add bearings, distances, and/or curve data as marked. See redlineso � � Re�poi�se: Red�ines r�ot p�c���l��d to surveyor. Plat revisions m�de Comment Number: 4 Comment Originated: 02/11/2016 02/11/2016: The area inside the building envelopes are existing Condos. Do those Condo owners need to sign the Plat? They own the Condos, but what about their LCE, GCE areas & access to their Condos? Response: Item is bei�g adc�ress��. No revision made at this time. Comment Number: 5 Comment Originated: 02/11/2016: There are no outer boundary monuments shown. Response: monuments shown. Comment Number: 6 Comment Originated: 02/11/2016: Why are there curves C1 & C2? The parent Plat is just one curve. See redlines. Response: no redlines provided to the surveyor. There are 2 curves on the parent plat. 1 curve is labeled with curve data the other is labeled as C3. Topic: Site Plan Comment Number: 7 02/11 /2016 02/11 /2016 Comment Originated: 02/11/2016 02/11/2016: Please remove "Centre Avenue Residences" from the title & title block. See redlines. Response: Title and title block have been updated Comment Number: 8 Comment Originated: 02/11/2016 02/11/2016: There are line over text issues. See redlines. .Response: no redlines provided to the surveyor. There are 2 curves on the parent plat. 1 curve is labelea with curve clata the other is labeled as C3. Comment Number: 9 Comment Originated: 02/11/2016 02/11/2016: Please correct the project name shown with "Site Plan". See redlines. Response: Project name updated Comment Number: 10 Comment Originated: 02/11/2016 02/11/2016: Please revise the legal description as marked. See redlines. Response: Legal description updated Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 02/17/2016 02/17/2016: no comments Response: Acknowledged Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson@fcgov.com Topic: General Comment Number: 1 Comment Originated: 02/16/2016 02/16/2016: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the L� Use Code. Direct questions concerning i�tion requirements to Eric Olson, at 221-6704 or eolson@fcgov.com Department: Water-Wastewater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 02/10/2016 02/10/2016: Sheet EX1: Ex. Conditions & Demo Plan Please provide callouts for all existing water and sanitary sewer taps with their sizes. See redlines for more info. Resp�nse: l_��.be!ecf existing water and s�nitai�y sewer services Comment Number: 2 Comment Originated: 02/10/2016 02/10/2016: Sheet U1: Utility Plan Provide callouts for the existing water and sewer services you intend to utilize with this project. Response: .Adde� c�.11o��ts ta s�rvi�es we intenC to use. Comment Number: 3 Comment Originated: 02/10/2016 02/10/2016: Sheet U1: Utility Plan Provide water meter size information for the new water service. Please note that the water meter cannot be within the bio-swale that you have proposed. Please also note that the water meter does not need to be in an easement, so you can remove the small pocket easement shown. R�sponse: Added water servi�e size and moved meier pit away from bio-swale. Comment Number: 4 Comment Originated: 02/10/2016 02/10/2016: Sheet U1: Utility Plan See redlines for other minor comments. Response: F�ckno���^�ledged Topic: Site Plan Comment Number: 5 Comment Originated: 02/10/2016 02/10/2016: Landscape Plans Landscape Note no. 1 needs to also include separation information between shrubs and water/sewer services: No shrubs shall be planted within 4' of water or sewer mains and/or service lines. Please update landscape plans accordingly if there are shrubs within 4' of service lines. t`�2Sp0i�Se: �'�,C�CnO'�;4'I2C'�I��C�I Comment Number: 1 02/17/2016: The 3 unit building needs to include Direct sidewalk connections from the units. Response: Side��Jalks have been added Department: Zoning Contact: Noah Beals, Topic: General 970-416-2313, nbeals@fcgov.com Comment Originated: 02/17/2016 Comment Number: 2 Comment Originated: 02/17/2016 02/17/2016: Is that a retaining wall along the west and south side of the 3 unit? R�s}�ons�: C�on�re�e biosv��aJe Comment Numk,� 3 �mment Originated: 02/17/2016 02/17/2016: Please provide a detail of the garage to show how the required bike spaces fit. Response: Comment is being addressed Is there a fixed bike rack near the 6 unit bailing? Response: No bike rack is currently proposed in this location Comment Number: 4 Comment Originated: 02/17/2016 02/17/2016: Comment Number: 5 Comment Originated: 02/17/2016 02/17/2016: Need to include a sheet index on the site plan. Respo:~�se: Sheet index added Comment Number: 6 Comment Originated: 02/17/2016 02/17/2016: The light fixture states in comes in two different temperature levels. Please add a note the the 3000K temperature is the one that will be used Response: 3000K Note added Comment Number: 7 Comment Originated: 02/17/2016 02/17/2016: Where are the elevations for the garage? Fiesponse: Elevations updated Comment Number: 8 Comment Originated: 02/17/2016 02/17/2016: Need more trees along the west and south side of the 3 unit Building Response: Trees have be�n added